Sample records for joint sealant material

  1. New Joint Sealants. Criteria, Design and Materials.

    ERIC Educational Resources Information Center

    Building Research Inst., Inc., Washington, DC.

    Contents include--(1) sealing concrete joints, (2) sealing glass and metal joints, (3) metal and glass joint sealants from a fabricator's viewpoint, (4) a theory of adhesion for joint sealants, (5) geometry of simple joint seals under strain, (6) joint sealant specifications from a manufacturer's viewpoint, (7) joint sealant requirements from an…

  2. Joint sealant materials for concrete pavement repairs.

    DOT National Transportation Integrated Search

    1991-01-01

    This report on joint sealant materials for concrete pavement repairs is based on conversations with specialists from several states, the Federal Highway Administration, the Portland Cement Association, and the American Concrete Pavement Association, ...

  3. Evaluation of joint sealant materials : final report.

    DOT National Transportation Integrated Search

    1977-05-01

    In May, 1968, the Department's Research and Development Section initiated a project to evaluate joint sealants being marketed for use on roads and bridges. In the study, representatives of 31 companies installed 40 products primarily on one road and ...

  4. Product evaluation : Ruscoe 983 joint sealant

    DOT National Transportation Integrated Search

    1986-07-10

    This report contains a product evaluation of Ruscoe's 983 joint sealant. Ruscoe 983 is an asphalt base single compound joint sealant. It contains an aluminum fortified adhesive and is designed for use on highway expansion joints, bridge joints, and r...

  5. Durability of building joint sealants

    Treesearch

    Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams

    2009-01-01

    Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...

  6. Performance of concrete joint sealants in hot climates

    DOT National Transportation Integrated Search

    1987-11-01

    A research project was initiated in 1979 on project IR-17-1(126) to compare and evaluate several joint sealants. In 1982 another test section on project F 028-1-506 was established to evaluate several other sealants. This report documents the placeme...

  7. An accelerated exposure and testing apparatus for building joint sealants

    NASA Astrophysics Data System (ADS)

    White, C. C.; Hunston, D. L.; Tan, K. T.; Hettenhouser, J.; Garver, J. D.

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  8. An accelerated exposure and testing apparatus for building joint sealants.

    PubMed

    White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  9. Field evaluation of three joint sealants.

    DOT National Transportation Integrated Search

    1987-01-01

    The purpose of the study reported here was to evaluate the performance of three joint sealants compartmented (A) and closed cellular (B) preformed neoprene, and a two-component cold-mixed polysulfide (C)-- that were used in the interchanges for Inter...

  10. Developing a test method to investigate water susceptibility of joint and crack sealants.

    DOT National Transportation Integrated Search

    2016-10-31

    Sealants are commonly used to insulate cracks and joints preventing water from entering the underlying structure. However, extended exposure of sealants to water has shown to negatively impact sealants properties causing gradual degradation of sealan...

  11. Resealing concrete pavement joints

    DOT National Transportation Integrated Search

    1999-07-01

    The primary objective of this study was to evaluate the relative performance of the selected joint sealant materials. Other objectives were to determine the effect of selected sealant configurations and installation methods, and to identify sealant m...

  12. Assessment of Techcrete : a concrete repair material and joint sealant.

    DOT National Transportation Integrated Search

    2013-01-01

    Joint sealing and resealing is a commonly performed concrete pavement maintenance activity that serve : s : two : purposes. First, it minimizes water infiltration; second, it prevents intrusion of solid materials in the joints. There : are many seala...

  13. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Treesearch

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  14. A Systematic Approach to the Study of Accelerated weathering of Building Joint Sealants

    Treesearch

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; James J. Filliben; Adam L. Pintar; Greg Schueneman

    2012-01-01

    An accurate service life prediction model is needed for building joint sealants in order to greatly reduce the time to market of a new product and reduce the risk of introducing a poorly performing product into the marketplace. A stepping stone to the success of this effort is the precise control of environmental variables in a laboratory accelerated test apparatus in...

  15. Fibrin Sealant: The Only Approved Hemostat, Sealant, and Adhesive—a Laboratory and Clinical Perspective

    PubMed Central

    Spotnitz, William D.

    2014-01-01

    Background. Fibrin sealant became the first modern era material approved as a hemostat in the United States in 1998. It is the only agent presently approved as a hemostat, sealant, and adhesive by the Food and Drug Administration (FDA). The product is now supplied as patches in addition to the original liquid formulations. Both laboratory and clinical uses of fibrin sealant continue to grow. The new literature on this material also continues to proliferate rapidly (approximately 200 papers/year). Methods. An overview of current fibrin sealant products and their approved uses and a comprehensive PubMed based review of the recent literature (February 2012, through March 2013) on the laboratory and clinical use of fibrin sealant are provided. Product information is organized into sections based on a classification system for commercially available materials. Publications are presented in sections based on both laboratory research and clinical topics are listed in order of decreasing frequency. Results. Fibrin sealant remains useful hemostat, sealant, and adhesive. New formulations and applications continue to be developed. Conclusions. This agent remains clinically important with the recent introduction of new commercially available products. Fibrin sealant has multiple new uses that should result in further improvements in patient care. PMID:24729902

  16. Replacement Non-Toxic Sealants for Standard Chromated Sealants

    DTIC Science & Technology

    2005-02-01

    material’s mechanical or physical properties and resistance to degradation. As sealant formulations for the Class B-2 worklife were developed by PRC...results ofthis testing, Class B-1I2 and C-12 worklife materials were formulated and are being tested. In addition to the testing that UDRI conducted, two...successfully accomplished in this program. An optimized Class B-2 worklife of the sealant compound designated RW3758-71, Lot no. RT0946, completed

  17. Fissure sealant materials: Wear resistance of flowable composite resins

    PubMed Central

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics. PMID:27651887

  18. Fissure sealant materials: Wear resistance of flowable composite resins.

    PubMed

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  19. Microleakage and penetration depth of different fissure sealant materials after cyclic thermo-mechanic and brushing simulation.

    PubMed

    Hatirli, Hüseyin; Yasa, Bilal; Yasa, Elif

    2018-01-30

    The aim of the study was to evaluate microleakage and the penetration-depths of different fissure-sealant materials applied with/without enameloplasty after cyclic aging. One-hundred-sixty mandibular molars were divided into non-invasive and enameloplasty preparation groups and eight material subgroups, including: flowable composites (microhyrid, nanohybrid, and nanofilled), three resin-based (unfilled, filled, and highly-filled), a giomer-based, and a glass-ionomer-based fissure sealant. Specimens were subjected to two-year cyclic chewing and brushing simulation. After 5% basic-fuchsin dye penetration, specimens were sectioned and scored under stereomicroscope. Kruskal-Wallis statistical data showed that preparation type significantly affected the penetration of all tested materials (p<0.05), but not significantly affected microleakage (p>0.05). Flowable composites showed the best and the glass-ionomer-based sealant showed the worst penetration and microleakage. Slight preparation of fissures is not important in microleakage. However, enameloplasty significantly enhanced the depth of penetration of the sealants. Flowable composites offer promising results at the fissure sealing.

  20. Design, fabrication, and implementation of thermally driven outdoor testing devices for building joint sealants.

    PubMed

    White, C C; Tan, K T; O'Brien, E P; Hunston, D L; Chin, J W; Williams, R S

    2011-02-01

    The paper describes the development, implementation, and testing of two thermally driven outdoor exposure instruments. These devices are unique in their ability to impose field generated thermally induced strain on sealant specimens while monitoring their resulting load and displacement. The instruments combine a fixed wood and steel supporting frame with a moving polyvinyl chloride frame, and employ differences in the coefficients of thermal expansion between the supporting frame and moving frame to induce strain on the sealant specimens. Two different kinds of instruments have been fabricated, "winter/tension" and "winter/compression" designs. In the winter/tension design, the thermally induced dimensional change is directly transferred to the specimens; while in the winter/compression design, the samples are loaded in an opposite direction with the dimensional change. Both designs are instrumented to monitor load and displacement and are built so that the strain on the specimen does not exceed ±25% over the range of temperatures expected in Gaithersburg, MD. Additionally, a weather station is colocated with the device to record environmental conditions in 1 min intervals. This combination of weather information with mechanical property data enables a direct link between environmental conditions and the corresponding sealant response. The reliability and effectiveness of these instruments are demonstrated with a typical sealant material. The results show that the instruments work according to the design criteria and provide a meaningful quantitative platform to monitor the mechanical response of sealant exposed to outdoor weathering.

  1. Study of sealing practices for rigid pavement joints.

    DOT National Transportation Integrated Search

    1971-01-01

    The joint sealing materials and the rigid pavement joint sealing practices employed by Virginia and other highway agencies were studied. The studies showed that Virginia's sealant and joint designs were in need of updating and that higher quality pou...

  2. Evaluation of joint sealant materials : interim report No. 1.

    DOT National Transportation Integrated Search

    1972-03-01

    This report illustrates some of the problems caused by ineffectively sealed joints and points to the great need for properly sealing joints in both concrete pavements and structures. : The principles of design including slab lengths, joint dimensions...

  3. Laser fluorescence of dentin caries covered with a novel nano-filled sealant.

    PubMed

    Braun, Andreas; Beisel, Christian; Brede, Olivier; Krause, Felix

    2013-01-01

    The aim of the present study was to assess the possibility to measure caries-induced laser fluorescence underneath a novel nano-filled fissure sealant. Sixty freshly extracted human teeth with occlusal dentine carious lesions were horizontally divided, exposing the respective lesion. Teeth were randomly assigned to three groups: (I) white fissure sealant with filler particles (Fissurit F, Voco), (II) clear fissure sealant without filler particles (Fissurit, Voco) and (III) novel experimental fissure sealant with nano-filler particles (Voco). Starting with a sealant thickness of 3 mm, laser fluorescence measurements (DIAGNOdent, KaVo) were performed after finishing the sealant surfaces with polishing papers, reducing the material at intervals of 0.5 mm until the sealant was removed completely. Evaluating a thickness of 0.5 mm, both the clear (83 % of the baseline fluorescence after fine grit polishing) and the white sealant (25 %) did not allow to measure baseline fluorescence (p < 0.05) with no fluorescence reduction in the experimental sealant group (p > 0.05). With increasing sealer thickness, fluorescence was influenced even by the experimental material (89 % of the baseline value at 1 mm). However, by using the experimental material, statistically significant higher fluorescence values than those for the other materials under study (p < 0.05) were obtained. Thicker sealant layers and coarse grit polishing caused a decrease of laser fluorescence in all groups (p < 0.05). Employing the experimental nano-filled sealant, laser fluorescence measurements for caries detection can be performed through thicker sealant layers compared to conventional sealant materials. Thus, it might be possible to use this material to assess a caries progression underneath the sealant and administer an appropriate therapy in due time.

  4. Dental sealants

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...

  5. A One-Year Evaluation of a Free Fissure Sealant Program.

    PubMed

    M, Bakhtiar; N, Azadi; A, Golkari

    2016-12-01

    Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran's oral health reform plan is not clear. To evaluate the longevity of different fissure sealant applied in Iran's oral health reform plan in Fars Province (south of Iran) after one year. Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant ( p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child's gender, age, and being caries-free. Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application.

  6. A One-Year Evaluation of a Free Fissure Sealant Program

    PubMed Central

    M, Bakhtiar; N, Azadi; A, Golkari

    2016-01-01

    Statement of Problem: Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran’s oral health reform plan is not clear. Objectives: To evaluate the longevity of different fissure sealant applied in Iran’s oral health reform plan in Fars Province (south of Iran) after one year. Materials and Methods: Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Results: Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant (p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child’s gender, age, and being caries-free. Conclusions: Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application. PMID

  7. Parametric Study of Sealant Nozzle

    NASA Astrophysics Data System (ADS)

    Yamamoto, Yoshimi

    It has become apparent in recent years the advancement of manufacturing processes in the aerospace industry. Sealant nozzles are a critical device in the use of fuel tank applications for optimal bonds and for ground service support and repair. Sealants has always been a challenging area for optimizing and understanding the flow patterns. A parametric study was conducted to better understand geometric effects of sealant flow and to determine whether the sealant rheology can be numerically modeled. The Star-CCM+ software was used to successfully develop the parametric model, material model, physics continua, and simulate the fluid flow for the sealant nozzle. The simulation results of Semco sealant nozzles showed the geometric effects of fluid flow patterns and the influences from conical area reduction, tip length, inlet diameter, and tip angle parameters. A smaller outlet diameter induced maximum outlet velocity at the exit, and contributed to a high pressure drop. The conical area reduction, tip angle and inlet diameter contributed most to viscosity variation phenomenon. Developing and simulating 2 different flow models (Segregated Flow and Viscous Flow) proved that both can be used to obtain comparable velocity and pressure drop results, however; differences are seen visually in the non-uniformity of the velocity and viscosity fields for the Viscous Flow Model (VFM). A comprehensive simulation setup for sealant nozzles was developed so other analysts can utilize the data.

  8. Joint sealant study

    DOT National Transportation Integrated Search

    1987-09-01

    ADOT has approximately 550 lane miles of jointed portland cement pavement under its jurisdiction. The current practice is to saw and seal the joints at the time of construction and reseal the joints under a rehabilitation project. ADOT does not speci...

  9. Microleakage and penetration of a hydrophilic sealant and a conventional resin-based sealant as a function of preparation techniques: a laboratory study.

    PubMed

    Khogli, Ahmed Eltigani; Cauwels, Rita; Vercruysse, Chris; Verbeeck, Ronald; Martens, Luc

    2013-01-01

    Optimal pit and fissure sealing is determined by surface preparation techniques and choice of materials. This study aimed (i) to compare the microleakage and penetration depth of a hydrophilic sealant and a conventional resin-based sealant using one of the following preparation techniques: acid etching (AE) only, a diamond bur + AE, and Er:YAG laser combined with AE, and (ii) to evaluate the microleakage and penetration depth of the hydrophilic pit and fissure sealant on different surface conditions. Eighty recently extracted 3rd molars were randomly assigned to eight groups of ten teeth according to the material, preparation technique, and surface condition. For saliva contamination, 0.1 mL of fresh whole human saliva was used. All samples were submitted to 1000 thermal cycles and immersed in 2% methylene blue dye for 4 h. Sections were examined by a light microscope and analysed using image analysis software (Sigmascan(®)). The combination of Er:YAG + AE + conventional sealant showed the least microleakage. The sealing ability of the hydrophilic sealant was influenced by the surface condition. Er:YAG ablation significantly decreased the microleakage at the tooth-sealant interface compared to the non-invasive technique. The hydrophilic sealant applied on different surface conditions showed comparable result to the conventional resin-based sealant. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  10. Sealants in dentistry: a systematic review of the literature.

    PubMed

    Condò, R; Cioffi, A; Riccio, A; Totino, M; Condò, S G; Cerroni, L

    2013-03-01

    The occlusal surface is the most affected area by dental caries and the sealing of the pits and of the fissures has been found, in time, the preventive method most effective trying to counteract the onset. Currently, the WHO considers it as a primary preventive measure, in other words one of the most effective and least invasive available to ensure the complete protection and the total preservation of the occlusal carious by the phenomenon. THE AIM OF THIS WORK HAS BEEN TO PERFORM A SYSTEMATIC REVIEW OF THE LITERATURE ON CLINICAL TRIALS OF DIFFERENT SEALING MATERIALS, IN ORDER TO: compare their individual characteristics, highlight the reliability and the long-term efficacy and identify the most significant variables, both technological and clinics, in order to declare whether or not the success of this method prior. The research has been carried out in the MEDLINE database by choosing keywords as "sealants" and "follow up". Only studies published in the last thirteen years have been considered and have been evaluated only types of scientific articles that fall within the definition of Anglo-Saxon "Clinical Trial" and "Controlled Clinical Trial", excluding all experimental works in vitro, case-reports, meta-analyzes and literature reviews. Have been also considered only scientific papers on patients between the ages of 0 and 18 years. Out of 29 studies, evaluating a total of 2900 individuals (aged between 2.5 and 17 years), 7411 seals made by using resin-based sealants (RB Sealants), modified glass ionomer sealants (RMGI) and compomer sealants have been analyzed. The best retention capacity of the material in time has been obtained from the use of RB Sealants compared to RMGI, demonstrating retention values much lower with partial loss of material at a distance of one year from the clinic. The compomers demonstrate retention values intermediates. The incidence of caries in a year is negligible for all sealants application. In terms of retention, resin

  11. High performance channel injection sealant invention abstract

    NASA Technical Reports Server (NTRS)

    Rosser, R. W.; Basiulis, D. I.; Salisbury, D. P. (Inventor)

    1982-01-01

    High performance channel sealant is based on NASA patented cyano and diamidoximine-terminated perfluoroalkylene ether prepolymers that are thermally condensed and cross linked. The sealant contains asbestos and, in its preferred embodiments, Lithofrax, to lower its thermal expansion coefficient and a phenolic metal deactivator. Extensive evaluation shows the sealant is extremely resistant to thermal degradation with an onset point of 280 C. The materials have a volatile content of 0.18%, excellent flexibility, and adherence properties, and fuel resistance. No corrosibility to aluminum or titanium was observed.

  12. PCC/AC shoulder joint seal evaluation

    DOT National Transportation Integrated Search

    1999-05-07

    This report presents the findings on the evaluation of Crafco Incorporated Roadsaver 903 SL Silicone Sealant and Dow Corning 890 SL Silicone Sealant. The Research Technical Panel had proposed to use the two self-leveling silicone joint sealants in te...

  13. Wide temperature range seal for demountable joints

    DOEpatents

    Sixsmith, Herbert; Valenzuela, Javier A.; Nutt, William E.

    1991-07-23

    The present invention is directed to a seal for demountable joints operating over a wide temperature range down to liquid helium temperatures. The seal has anti-extrusion guards which prevent extrusion of the soft ductile sealant material, which may be indium or an alloy thereof.

  14. Chemical research projects office fuel tank sealants review. [flight testing of fluorosilicone sealants

    NASA Technical Reports Server (NTRS)

    Rosser, R. W.; Parker, J. A.

    1974-01-01

    The status of high-temperature fuel tank sealants for military and potentially commercial supersonic aircraft is examined. The interrelationships of NASA's sealants program comprise synthesis and development of new fluoroether elastomers, sealant prediction studies, flight simulation and actual flight testing of best state-of-the-art fluorosilicone sealants. The technical accomplishments of these projects are reviewed.

  15. Reflectivity of crack sealant.

    DOT National Transportation Integrated Search

    2002-01-01

    Crack sealing is used in road maintenance but presents a problem when crack seal material visually pops out on the roadway, making it difficult to see lane stripes. This problem will increase as New Mexico increases its use of crack sealants. This su...

  16. Wide temperature range seal for demountable joints

    DOEpatents

    Sixsmith, H.; Valenzuela, J.A.; Nutt, W.E.

    1991-07-23

    The present invention is directed to a seal for demountable joints operating over a wide temperature range down to liquid helium temperatures. The seal has anti-extrusion guards which prevent extrusion of the soft ductile sealant material, which may be indium or an alloy thereof. 6 figures.

  17. Dental Sealants Prevent Cavities

    MedlinePlus

    ... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  18. Design, development, and testing of a hybrid in situ testing device for building joint sealant

    Treesearch

    C. White; N. Embree; C. Buch; R.S. Williams

    2005-01-01

    The testing of sealant samples has been restricted to devices that either focus on fatiguing multiple samples or quantifying the mechanical properties of a single sample. This manuscript describes a device that combines these two instrumental designs: the ability to both fatigue and characterize multiple sealant samples at the same time. This device employs precise...

  19. Bond strength of Bis-GMA and glass ionomer pit and fissure sealants using cyclic fatigue.

    PubMed

    Dewji, H R; Drummond, J L; Fadavi, S; Punwani, I

    1998-02-01

    The aim of the study was to determine the bond strength of glass ionomer and resin-modified glass ionomer sealants compared to Bis-GMA sealants using both static and cyclic fatigue shear testing. Four materials were evaluated: D, a Bis-GMA sealant with 10% phosphoric acid etchant; FC, a resin-modified glass ionomer sealant with 20% polyacrylic acid etchant; FD, a resin-modified glass ionomer sealant with 10% polyacrylic acid etchant; and FSC, a self-cured glass ionomer sealant with no etchant. Gelatin capsules filled with the sealant material were bonded to the enamel surfaces of bovine teeth after appropriate surface conditioning and then tested in shear static and cyclic fatigue. Static and cyclic shear bond strengths, respectively, for each group were (MPa): FC: 21.1+/-2.8 and 17.1+/-3.1; FD: 14.6+/-5.9 and 8.5+/-3.1; D: 10.8+/-4.9 and 4.7+/-2.6; FSC: 8.7 (1.0 and 2.9+/-0.6. The resin-modified glass ionomer sealants had better fatigue bond strength than both Bis-GMA and self-cured glass ionomer sealants with the surface conditioning affecting the bond strength of the resin-modified glass ionomer sealants.

  20. Near-infrared imaging of demineralization under sealants

    NASA Astrophysics Data System (ADS)

    Tom, Henry; Simon, Jacob C.; Chan, Kenneth H.; Darling, Cynthia L.; Fried, Daniel

    2014-07-01

    Previous studies have shown that near-infrared (NIR) reflectance and transillumination imaging can be used to acquire high contrast images of early caries lesions and composite restorative materials. The aim of the study was to determine the optimum NIR wavelengths for imaging demineralized areas under dental sealants. Fifteen natural human premolars and molars with occlusal lesions were used in this in vitro study. Images before and after application of sealants were acquired using NIR reflectance and NIR transillumination at wavelengths of 1300, 1460, and 1500 to 1700 nm. Images were also acquired using polarization sensitive optical coherence tomography (OCT) for comparison. The highest contrast for NIR reflectance was at 1460 nm and 1500 to 1700 nm. These NIR wavelengths are coincident with higher water absorption. The clear Delton sealant investigated was not visible in either copolarization or cross-polarization OCT images. The wavelength region between 1500 and 1700 nm yielded the highest contrast of lesions under sealants for NIR reflectance measurements.

  1. Near-infrared imaging of demineralization under sealants.

    PubMed

    Tom, Henry; Simon, Jacob C; Chan, Kenneth H; Darling, Cynthia L; Fried, Daniel

    2014-01-01

    Previous studies have shown that near-infrared (NIR) reflectance and transillumination imaging can be used to acquire high contrast images of early caries lesions and composite restorative materials. The aim of the study was to determine the optimum NIR wavelengths for imaging demineralized areas under dental sealants. Fifteen natural human premolars and molars with occlusal lesions were used in this in vitro study. Images before and after application of sealants were acquired using NIR reflectance and NIR transillumination at wavelengths of 1300, 1460, and 1500 to 1700 nm. Images were also acquired using polarization sensitive optical coherence tomography (OCT) for comparison. The highest contrast for NIR reflectance was at 1460 nm and 1500 to 1700 nm. These NIR wavelengths are coincident with higher water absorption. The clear Delton sealant investigated was not visible in either copolarization or cross-polarization OCT images. The wavelength region between 1500 and 1700 nm yielded the highest contrast of lesions under sealants for NIR reflectance measurements.

  2. Joint strength of a solid oxide fuel cell glass-ceramic sealant with metallic interconnect in a reducing environment

    NASA Astrophysics Data System (ADS)

    Lin, Chih-Kuang; Liu, Yu-An; Wu, Si-Han; Liu, Chien-Kuo; Lee, Ruey-Yi

    2015-04-01

    Effects of reducing environment and thermal aging on the joint strength of a BaO-B2O3-Al2O3-SiO2 glass-ceramic sealant (GC-9) with a ferritic-stainless-steel interconnect (Crofer 22 H) for planar solid oxide fuel cells are investigated. A technique is developed for conducting mechanical tests at room temperature and 800 °C in H2-7 vol% H2O under shear and tensile loadings. Given an aged condition and loading mode, the joint strength at 800 °C is lower than that at room temperature in the given humidified hydrogen atmosphere. A thermal aging at 800 °C in H2-7 vol% H2O for 100 h or 1000 h enhances both shear and tensile joint strengths at room temperature but degrades them at 800 °C in the same reducing environment. Non-aged specimens show a comparable joint strength and fracture mode when tested in humidified hydrogen and in air under a given loading mode and testing temperature. The shear strength at 800 °C for joint specimens after a 1000-h thermal aging at 800 °C in air or humidified hydrogen is reduced by a similar extent of 19%, compared to the counterpart of non-aged joint specimens tested in the same oxidizing or reducing environment.

  3. A highly adhesive and naturally derived sealant.

    PubMed

    Assmann, Alexander; Vegh, Andrea; Ghasemi-Rad, Mohammad; Bagherifard, Sara; Cheng, George; Sani, Ehsan Shirzaei; Ruiz-Esparza, Guillermo U; Noshadi, Iman; Lassaletta, Antonio D; Gangadharan, Sidhu; Tamayol, Ali; Khademhosseini, Ali; Annabi, Nasim

    2017-09-01

    Conventional surgical techniques to seal and repair defects in highly stressed elastic tissues are insufficient. Therefore, this study aimed to engineer an inexpensive, highly adhesive, biocompatible, and biodegradable sealant based on a modified and naturally derived biopolymer, gelatin methacryloyl (GelMA). We tuned the degree of gelatin modification, prepolymer concentration, photoinitiator concentration, and crosslinking conditions to optimize the physical properties and adhesion of the photocrosslinked GelMA sealants. Following ASTM standard tests that target wound closure strength, shear resistance, and burst pressure, GelMA sealant was shown to exhibit adhesive properties that were superior to clinically used fibrin- and poly(ethylene glycol)-based glues. Chronic in vivo experiments in small as well as translational large animal models proved GelMA to effectively seal large lung leakages without the need for sutures or staples, presenting improved performance as compared to fibrin glue, poly(ethylene glycol) glue and sutures only. Furthermore, high biocompatibility of GelMA sealant was observed, as evidenced by a low inflammatory host response and fast in vivo degradation while allowing for adequate wound healing at the same time. Combining these results with the low costs, ease of synthesis and application of the material, GelMA sealant is envisioned to be commercialized not only as a sealant to stop air leakages, but also as a biocompatible and biodegradable hydrogel to support lung tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Sealant Microleakage After Using Nano-Filled Bonding Agents on Saliva-Contaminated Enamel

    PubMed Central

    Paryab, Mehrsa

    2013-01-01

    Objective: The efficacy of correctly applied fissure sealants has been revealed in the prevention of caries. Saliva and moisture contamination of the etched enamel surface before sealant placement can decrease the bonding strength of the sealant to the enamel. The aim of this study was to test the new bonding agents containing nano-fillers in order to reduce the negative effect of saliva contamination on the sealant micro leakage. Materials and Methods: Seventy five sound human premolars were randomly assigned to five equal groups as follows: Group A: etching, sealant; Group B: etching, saliva contamination, sealant; Group C: etching, saliva contamination, Single bond, sealant; Group D: etching, saliva contamination, Adper Single bond 2, sealant; Group E: etching, saliva contamination, N Bond, sealant. The samples were thermo-cycled and immersed in basic fuchsine 0.5% by weight. Then, the teeth were sectioned bucco-lingually and parallel to the long axis into two segments. Finally, the length of dye penetration at the sealant-tooth interface was scored according to a four-point scale. Results: Micro-leakage was higher in group B compared to the other groups, while there were no differences among the evaluated dentin adhesives. Conclusion: The use of nano-filled bonding agents as an intermediate layer between the etched enamel and the sealant can reduce sealant micro-leakage after saliva contamination at the level of the uncontaminated enamel. PMID:25512749

  5. ReSure Sealant for Pars Plana Vitrectomy Wound Closure.

    PubMed

    Ho, Vincent Y; Shah, Gaurav K; Liu, Enchun M

    2015-01-01

    ReSure Sealant (Ocular Therapeutix, Bedford, MA) is an ocular sealant that demonstrated both safety and effectiveness in a prospective, randomized clinical trial for sealing clear corneal incisions following cataract surgery and intraocular lens placement in adults.1 PATIENTS AND METHODS: This is the first literature report of ReSure Sealant used for the closure of 23-gauge (G) pars plana vitrectomy (PPV) sclerotomies. A 70-year-old pseudophakic female with a history of epiretinal membrane and branch retinal vein occlusion of the right eye underwent 23-G PPV, membrane peel, and air-fluid exchange and was found to have leaking subconjunctival air at the end of the case. A linear conjunctival incision was performed to access the sclerotomy site. The incisions were then carefully dried before the sealant was applied to seal both the sclera and conjunctiva. After polymerization, the sealant formed a polyethylene glycol (PEG) hydrogel that was 89% water and 9.44% PEG. PEG is a synthetic material that is non-toxic and inert and, thus, suitable for use in medical products. ReSure Sealant may be a safe, quick method to close sclerotomy wounds in select cases. [ Copyright 2015, SLACK Incorporated.

  6. Glass ionomer ART sealants in Chinese school children-6-year results.

    PubMed

    Holmgren, Christopher J; Lo, Edward C M; Hu, Deyu

    2013-09-01

    To evaluate longitudinally ART sealants placed in Chinese school children under field conditions. 191 ART sealants were placed in 140 children, aged 11-14 years, by five assistant dentists in four secondary schools in Deyang, Sichuan Province, China. Teeth selected for sealing were those with pits and fissures that were deep or showing early enamel caries. Teeth were excluded if there was obvious cavitation extending into dentine. Standard instruments and procedures for ART sealants were used. The material used was a high-viscosity glass-ionomer (Ketac-Molar, 3MESPE) that was inserted into the pits and fissures with the "press-finger" technique. The status of the sealants was evaluated annually over 6 years after placement by the same examiner who was not involved in the placement of the sealants using explorers, mouth-mirrors and an intra-oral fibre-optic light. No missing sealants were replaced during the study. 107 sealants (56% of the original) were examined after 6 years. The cumulative survival rates of the sealants (partially or fully retained) after 2, 4 and 6 years were 79%, 68% and 59%, respectively. Caries prevention lagged the fall in sealant survival but remained high throughout the study period, being over 90% in the first 4 years and 85% after 6 years. ART sealants placed under field conditions in Chinese schoolchildren have a high retention rate. Missing sealants should be replaced to maintain their preventive efficacy. The sealing of pits and fissures can be an effective caries preventive approach. Resin-based sealants have the disadvantage in that they require an optimal level of moisture control during placement. In children and in outreach situations glass ionomer ART sealants, which are more moisture tolerant, can offer a viable alternative. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Adhesion mechanisms of bituminous crack sealant to aggregate and laboratory test development

    NASA Astrophysics Data System (ADS)

    Hajialiakbari Fini, Elham

    Crack sealing is a common pavement maintenance treatment because it extends pavement service life. However, crack sealant often fails prematurely due to a loss of adhesion. Since current test methods are mostly empirical and only provide a qualitative measure of bond strength, they cannot predict sealant adhesive failure accurately. Hence, there is an urgent need for test methods based on bituminous sealant rheology that can better predict sealant field performance. This study introduces three laboratory tests aimed to assess the bond property of hot-poured crack sealant to pavement crack walls. The three tests are designed to serve the respective needs of producers, engineers, and researchers. The first test implements the principle of surface energy to measure the thermodynamic work of adhesion, which is the energy spent in separating the two materials at the interface. The work of adhesion is reported as a measure of material compatibility at an interface. The second test is a direct adhesion test, a mechanical test which is designed to closely resemble both the installation process and the crack expansion due to thermal loading. This test uses the Direct Tension Test (DTT) device. The principle of the test is to apply a tensile force to detach the sealant from its aggregate counterpart. The maximum load, Pmax, and the energy to separation, E, are calculated and reported to indicate interface bonding. The third test implements the principles of fracture mechanics in a pressurized circular blister test. The apparatus is specifically designed to conduct the test for bituminous crack sealant, asphalt binder, or other bitumen-based materials. In this test, a fluid is injected at a constant rate at the interface between the substrate (aggregate or a standard material) and the adhesive (crack sealant) to create a blister. The fluid pressure and blister height are measured as functions of time; the data is used to calculate Interfacial Fracture Energy (IFE), which is a

  8. Research on Joint Sealant Materials to Improve Installation and Performance : Final Report

    DOT National Transportation Integrated Search

    2017-12-01

    The objectives of this project were to 1) identify failure modes and their mechanisms in joint seals in Texas, and to 2) identify what needs to be done to minimize the failures and improve joint seal performance. To achieve these objectives efficient...

  9. Overview of CO2 Leakage Problems and Sealants for CO2 Leakage Remediation

    NASA Astrophysics Data System (ADS)

    Peng, Shudai

    Excessive Carbon Dioxide (CO2) emission has become a serious issue and caused lots of environmental problems. Carbon Capture and Storage (CCS) program has been developed to reduce the CO2 content in the atmosphere. CO2 storage has been targeted mainly on depleted oil or gas reservoirs and deep saline aquifers. However, leakage could occur through wellbores, cap rocks, formation faults, and fractures during and after CO2 injection. To minimize the risk, different types of sealants have been investigated to prevent CO2 leaks. The aim of this thesis is to provide a comprehensive review of the materials which could be used as CO2 sealants. Based on the difference of materials components, this research has classified the sealants into seven types, including cements, geopolymers, foams, gel systems, resin systems, biofilm barriers, and nanoparticles. For each type of sealants, its chemical components, physical properties, stabilities, impact factors, applied environments, advantages and limitations were summarized. The most commonly used sealant for CO2 leakage control from wellbore is still cement, and the aluminate-calcium based cement has the best properties. It is very challenging to seal the fractures and faults, far from wellbore due to the difficulty to deliver plugging materials into the in-depth of a reservoir. The thermo-stability is also a great challenge for most materials and should be evaluated under supercritical CO2 condition.

  10. Fibrin sealant: past, present, and future: a brief review.

    PubMed

    Spotnitz, William D

    2010-04-01

    Fibrin sealant is a two-component topical hemostat, sealant, and tissue adhesive consisting of fibrinogen and thrombin that has been used in the United States as a blood bank- or laboratory-derived product since the 1980s and has been commercially available since 1998. Initially, surgeons employed hospital-based materials because of the lack of availability of a commercially produced agent. At present, there are five U.S. Food and Drug Administration (FDA)-approved forms including products derived from pooled or autologous human plasma as well as bovine plasma. On-label indications include hemostasis, colonic sealing, and skin graft attachment. Recent clinical and experimental uses include tissue or mesh attachment, fistula closure, lymphatic sealing, adhesion prevention, drug delivery, and tissue engineering. The modern literature on fibrin sealant now exceeds 3000 articles and continues to expand. This brief review presents the history of this material, its present clinical use, and its future applications.

  11. Evaluation of Solubility and Microleakage of Glass Carbomer Sealant.

    PubMed

    Subramaniam, P; Girish Babu, K L; Jayasurya, S

    2015-01-01

    This study was carried out to evaluate and compare solubility and microleakage of the newly introduced moisture tolerant glass carbomer sealant. For evaluation of solubility, 20 specimens of glass carbomer and conventional glass ionomer were prepared and immersed in artificial saliva of pH 4 and 6 for seven days. The difference between initial and final weight was calculated. For evaluation of microleakage, glass carbomer was compared with a conventional resin sealant. 20 premolar teeth indicated for orthodontic extraction were collected and divided into two groups and the respective sealants were applied. It was subjected to thermocycling and then kept immersed in methylene blue for 24 hours. Dye penetration was scored. The glass carbomer specimens were less soluble than the conventional glass ionomer at both pH values. There was no significant difference in the microleakage. Being moisture resistant, glass carbomer can be used as an alternative fissure sealant material; especially in young children with partially erupted teeth and where obtaining moisture control is difficult.

  12. Ability Of Optical Coherence Tomography To Detect Caries Beneath Commonly Used Dental Sealants

    PubMed Central

    Osann, Kathryn; Pharar, Jessica; Lee, Kenneth; Ahn, Yeh-chan; Tucker, Travis; Sabet, Sharareh; Chen, Zhongping; Gukasyan, Ripsik; Wilder-Smith, Petra

    2010-01-01

    Background and Objective The onset and progression of early tooth decay is often preventable with dental sealants. However, occasionally decay progresses underneath the sealant. Current technology does not permit monitoring of potential lesion progression or arrest. Dental sealants themselves mask the visual cues that identify early tooth decay, and radiographs are not sufficiently sensitive. Therefore clinicians can be reluctant to use dental sealant. The objective of this ex vivo study was to evaluate the ability of dentists to detect decay beneath commonly used dental sealants using Optical Coherence Tomography (OCT) imaging. Study Designs/Materials/Methods Forty extracted teeth were divided into equal groups of carious and non-carious teeth, as determined by visual inspection. After radiographs and OCT imaging, teeth were randomly assigned for sealant placement with one of four commonly purchased dental sealants: Clinpro™, Fuji Triage™, Embrace Wet Bond™, and Delton™. Following sealant placement, teeth were radiographed, imaged with OCT, sectioned, examined histologically, and scored as healthy/not healthy. OCT and radiographic images were scored separately. The gold standard was histopathological diagnosis from the serial sections. Cohen’s Kappa, sensitivity, negative predictive value and positive predictive value were computed for all measures. Results After 90 mins training, pre-standardized dentists were able to detect tooth decay more accurately using OCT than with visual or radiographic examination. Detection using OCT was somewhat better prior to sealant placement than afterwards. This effect varied in size depending on the type of sealant used. Radiographic diagnosis was also less accurate after sealant placement. Of the four dental sealants, Delton provided excellent positive predictive value and the best post-sealant negative predictive values. Conclusion In this ex vivo study, dentists were able to detect tooth decay beneath four commonly

  13. Pit and fissure sealants for preventing dental decay in permanent teeth.

    PubMed

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya; Nordblad, Anne; Mäkelä, Marjukka; Worthington, Helen V

    2017-07-31

    Dental sealants were introduced in the 1960s to help prevent dental caries, mainly in the pits and fissures of occlusal tooth surfaces. Sealants act to prevent bacteria growth that can lead to dental decay. Evidence suggests that fissure sealants are effective in preventing caries in children and adolescents compared to no sealants. Effectiveness may, however, be related to caries incidence level of the population. This is an update of a review published in 2004, 2008 and 2013. To compare the effects of different types of fissure sealants in preventing caries in occlusal surfaces of permanent teeth in children and adolescents. Cochrane Oral Health's Information Specialist searched: Cochrane Oral Health's Trials Register (to 3 August 2016), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2016, Issue 7), MEDLINE Ovid (1946 to 3 August 2016), and Embase Ovid (1980 to 3 August 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials to 3 August 2016. No restrictions were placed on language or date of publication. Randomised controlled trials (RCTs) comparing sealants with no sealant or a different type of sealant material for preventing caries of occlusal surfaces of premolar or molar teeth in children and adolescents aged up to 20 years. Studies required at least 12 months follow-up. We excluded studies that compared compomers to resins/composites. Two review authors independently screened search results, extracted data and assessed risk of bias of included studies. We presented outcomes for caries or no caries on occlusal surfaces of permanent molar teeth as odds ratio (OR) or risk ratio (RR). We used mean difference (MD) for mean caries increment. All measures were presented with 95% confidence intervals (CI). We conducted meta-analyses using a random-effects model for comparisons where there were more than three trials; otherwise we used the fixed

  14. Enamel Surface with Pit and Fissure Sealant Containing 45S5 Bioactive Glass.

    PubMed

    Yang, S-Y; Kwon, J-S; Kim, K-N; Kim, K-M

    2016-05-01

    Enamel demineralization adjacent to pit and fissure sealants leads to the formation of marginal caries, which can necessitate the replacement of existing sealants. Dental materials with bioactive glass, which releases ions that inhibit dental caries, have been studied. The purpose of this study was to evaluate the enamel surface adjacent to sealants containing 45S5 bioactive glass (BAG) under simulated microleakage between the material and the tooth in a cariogenic environment. Sealants containing 45S5BAG filler were prepared as follows: 0% 45S5BAG + 50.0% glass (BAG0 group), 12.5% 45S5BAG + 37.5% glass (BAG12.5 group), 25.0% 45S5BAG + 25.0% glass (BAG25.0 group), 37.5% 45S5BAG + 12.5% glass (BAG37.5 group), and 50.0% 45S5BAG + 0% glass (BAG50.0 group). A cured sealant disk was placed over a flat bovine enamel disk, separated by a 60-µm gap, and immersed in lactic acid solution (pH 4.0) at 37 °C for 15, 30, and 45 d. After the storage period, each enamel disk was separated from the cured sealant disk, and the enamel surface was examined with optical 3-dimensional surface profilometer, microhardness tester, and scanning electron microscopy. The results showed a significant increase in roughness and a decrease in microhardness of the enamel surface as the proportion of 45S5BAG decreased (P< 0.05). In the scanning electron microscopy images, enamel surfaces with BAG50.0 showed a smooth surface, similar to those in the control group with distilled water, even after prolonged acid storage. Additionally, an etched pattern was observed on the surface of the demineralized enamel with a decreasing proportion of 45S5BAG. Increasing the 45S5BAG filler contents of the sealants had a significant impact in preventing the demineralization of the enamel surface within microgaps between the material and the tooth when exposed to a cariogenic environment. Therefore, despite some marginal leakage, these novel sealants may be effective preventive dental materials for inhibiting

  15. Marginal microleakage of triage sealant under different moisture contamination.

    PubMed

    Peng, Yawen; Stark, Paul C; Rich, Alfred; Loo, Cheen Y

    2011-01-01

    Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva contamination with 10 seconds of air-drying; and (4) saliva contamination with reconditioning. Sealants were placed after contamination. All extracted teeth underwent thermocycling followed by 1% methylene blue dye and distilled water wash. All extracted teeth were then sectioned buccolingually into 3 cross-sections and examined at 60X under a stereomicroscope. Microleakage was assessed using a dye penetration scoring system (score=0-3). Data were analyzed with Kruskal-Wallis and Mann-Whitney tests. The control group showed significantly lower marginal leakage than the other 3 groups (P<.02). There was no statistically significant difference among the 3 contaminated groups (P>.34). Fuji Triage sealant had the least marginal leakage under a moisture-controlled environment. When saliva was introduced during the application of the material, microleakage significantly increased. When contamination occurred, 1-second air-thinning of the saliva, 10-second air-drying of the saliva, or reconditioning before sealant application did not show a difference in decreasing microleakage.

  16. A cost-effective analysis of fibrin sealants versus no sealant following open right hemihepatectomy for colorectal liver metastases.

    PubMed

    Pandanaboyana, Sanjay; Bell, Richard; Shah, Nehal; Lodge, J Peter A; Hidalgo, Ernest; Toogood, Giles J; Prasad, K Raj

    2017-06-01

    There is paucity of data regarding the cost-effectiveness of fibrin sealants during liver surgery. This study aimed to assess the cost-effectiveness of fibrin sealants following right hemihepatectomy for colorectal liver metastases. A prospectively maintained database between 2004 and 2013 was reviewed to identify patients who underwent a right hemihepatectomy with and without fibrin sealant application. Perioperative and post-operative outcomes were analysed to assess its cost-effectiveness. One hundred and sixty-three right hemihepatectomies were performed, of which 79 were in the fibrin sealant treatment group and 84 were in the no sealant group. No difference was seen between fibrin sealant and no sealant with regard to bile leak (P = 0.366), intra-abdominal collections (P = 0.200) and overall post-operative complications (P = 0.480). Operating costs were significantly cheaper in the no sealant group (P = 0.010). There was no difference seen in median post-operative stay between fibrin sealant versus no treatment (8 versus 9 days, P = 0.327), median total bed cost (£3900 versus £4300, P = 0.400), mean transfusion cost per patient (P = 0.201) and overall cost (£6706.15 versus £6555.80, P = 0.792). Fibrin sealant application to cut surface during liver surgery confers no cost benefit and their routine use may not be recommended. © 2014 Royal Australasian College of Surgeons.

  17. Glass ionomer ART sealant and fluoride-releasing resin sealant in fissure caries prevention – results from a randomized clinical trial

    PubMed Central

    2014-01-01

    Background The relative performance of ART sealant and fluoride-releasing resin sealant in preventing fissure caries in permanent molars was compared in a randomized clinical trial conducted in southern China (ClinicalTrials.gov NCT01829334). Methods After obtaining ethical approval, healthy schoolchildren who had permanent first molars with occlusal fissures which were sound but deep or presented with only incipient caries were recruited for the study. Included molars were randomly allocated into one of four parallel study groups in units of left/right teeth per mouth. Two of the four groups adopted the methods of ART or fluoride-releasing resin sealant placement while the other two groups adopted the topical fluoride application methods. Fissure status of the molars in each group was evaluated every 6 months. Development of dentine caries and sealant retention over 24 months in the molars in the two sealant-using groups was compared in this report. Outcome on cost-effectiveness of all four groups over 36 months will be reported elsewhere. Results At baseline, a total of 280 children (383 molars) with mean age 7.8 years were involved for the two sealant groups. After 24 months, 261 children (357 molars) were followed. Proportions of molars with dentine caries were 7.3% and 3.9% in the ART sealant and fluoride-releasing resin sealant groups, respectively (chi-square test, p = 0.171). Life-table survival analysis showed that sealant retention (full and partial) rate over 24 months for the resin sealant (73%) was significantly higher than that (50%) for the ART sealant (p < 0.001). Molar survival (no development of dentine caries) rates in the ART sealant (93%) and fluoride-releasing resin sealant (96%) groups were not significantly different (p = 0.169). Multilevel logistic regression (GEE modeling) accounting for the effects of data clustering and confounding factors confirmed this finding. Conclusions Though the retention of fluoride

  18. Biodegradable-Polymer-Blend-Based Surgical Sealant with Body-Temperature-Mediated Adhesion.

    PubMed

    Behrens, Adam M; Lee, Nora G; Casey, Brendan J; Srinivasan, Priya; Sikorski, Michael J; Daristotle, John L; Sandler, Anthony D; Kofinas, Peter

    2015-12-22

    The development of practical and efficient surgical sealants has the propensity to improve operational outcomes. A biodegradable polymer blend is fabricated as a nonwoven fiber mat in situ. After direct deposition onto the tissue of interest, the material transitions from a fiber mat to a film. This transition promotes polymer-substrate interfacial interactions leading to improved adhesion and surgical sealant performance. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Selective removal of composite sealants with near-UV laser pulses

    NASA Astrophysics Data System (ADS)

    Louie, Tiffany M.; Jones, Robert S.; Sarma, Anupama V.; Fried, Daniel

    2004-05-01

    It is often necessary to replace pit and fissure sealants and composite restorations. This task is complicated by the necessity for complete removal of the remaining composite to enable suitable adhesion of new composite. Previous studies have shown that lasers pulses from a frequency-tripled Nd:YAG laser (355-nm) can selectively remove residual composite after orthodontic bracket removal on enamel surfaces. UV laser light is preferentially absorbed by polymeric resins and the organic content of the tooth enamel. The objective of this study was to determine if such laser pulses are suitable for selective removal of the old composite from pit and fissure sealants and restorations without damaging surrounding sound tissues. Optical coherence tomography was used to acquire optical cross sections of the occlusal topography and peripheral tooth structure non-destructively before application of the sealants, after sealant application, and after sealant removal with 355-nm laser pulses with intensities ranging from 0-10 J/cm2. Thermocouples were used to monitor the temperature in the pulp chamber during composite removal under clinically relevant ablation rates, i.e., 30 Hz and 30 mJ per laser pulse. At an irradiation intensity of 1.3 J/cm2 pit and fissure sealants were completely removed without visible damage to the underlying enamel. At intensities above 1.5 J/cm2, the laser removes the resin layer while at the same time preferentially etching the surface of the enamel. Temperature excursions in the pulp chamber of extracted teeth was limited to less than 5°C if air-cooling was used during the rapid removal (1-2 min) of sealants, water-cooling was not needed. This is the first presentation of a method for the selective removal of composite restorative materials without damage to the underlying sound tooth structure.

  20. Evaluation of microtensile bond strength of different fissure sealants to bovine enamel.

    PubMed

    Sen Tunc, E; Bayrak, S; Tuloglu, N; Ertas, E

    2012-03-01

    The aim of this study was to evaluate the microtensile bond strength (μTBS) of a new fissure sealant and compare it with conventional sealants which are applied to enamel alone, and also with self-etch and etch-and-rinse adhesives. Enamel specimens were prepared and randomly distributed into three groups according to fissure sealant (Aegis, Helioseal F, Helioseal Clear). Each group was then subdivided according to adhesive system (Clearfil S3, Single Bond, no adhesive). A universal testing machine was used to measure μTBS, and data were analysed using one-way ANOVA and Tukey's tests. μTBS values for all Aegis subgroups were significantly lower than for comparable Helioseal F and Helioseal Clear subgroups (p < 0.05). No differences were observed in μTBS of Helioseal F and Helioseal Clear (p > 0.05). In the Helioseal Clear group, μTBS values for Single Bond were significantly higher than for Clearfil S3 (p < 0.05). However, no significant differences were found between the μTBS values of the adhesive subgroups in the Aegis or Helioseal F groups (p > 0.05). Sealant μTBS values may be affected by material content. The addition of an adhesive may improve μTBS values of sealant to enamel. © 2012 Australian Dental Association.

  1. Development of apparent viscosity test for hot-poured crack sealants.

    DOT National Transportation Integrated Search

    2008-11-01

    Current crack sealant specifications focuses on utilizing simple empirical tests such as penetration, : resilience, flow, and bonding to cement concrete briquettes (ASTM D3405) to measure the ability of the material : to resist cohesive and adhesion ...

  2. Pneumostasis of experimental air leaks with a new photopolymerized synthetic tissue sealant.

    PubMed

    Ranger, W R; Halpin, D; Sawhney, A S; Lyman, M; Locicero, J

    1997-09-01

    Air leak is a major contributor to increased length of stay and postoperative morbidity following pulmonary surgery. The effectiveness of a new photopolymerized synthetic hydrogel (FocalSeal, Focal, Inc., Lexington, MA) as a sealant for pulmonary air leaks was determined in 10 mongrel dogs (20-35 kg). The animals were anesthetized and underwent left-sided anterolateral thoracotomy with amputation of a 2 x 3-cm segment of the lung apex. Hemostasis was achieved and terminal bronchial openings of 1.5 to 3 mm with vigorous air leaks were identified. After successful injury, the dogs were randomly assigned to sealant (n = 5) or control (n = 5) groups. In treated animals, the sealant was applied by brushing the solution to the cut parenchymal surface and solidified while briefly interrupting ventilation (40-60 seconds) using visible illumination (450-550 nm) from a xenon light source. Controls received no sealant. A single chest tube was maintained at the injury site with a continuous negative pressure of 20 cm of water. All dogs were extubated and allowed to breathe spontaneously under sedation for 24 hours. Chest radiographs were taken postsurgery and presacrifice. All control animals (n = 5) showed persistent vigorous air leak for the duration of the 24-hour observation period. All treated air leaks resolved immediately, and four of five remained sealed throughout the observation period. One leak reappeared after 17 hours due to inadequate sealant thickness over a 3-mm terminal bronchus. Gross evaluation of the treatment group at the end of 24 hours demonstrated intact sealant well adherent to the parenchyma. No evidence of atelectasis or excessive edema was seen, and no sealant-related complications or toxic effects were noted. Radiologically, lungs were fully inflated. Histologic evaluation at 24 hours revealed no evidence of a strong cellular response to the synthetic sealant, and no fibrosis or adhesions were seen, the onset of the healing process was favorable

  3. Wear of two pit and fissure sealants in contact with primary teeth

    PubMed Central

    Galo, Rodrigo; Contente, Marta Maria Martins Giamatei; Borsatto, Maria Cristina

    2014-01-01

    Objectives: Wear simulations may provide an indication of the clinical performance of pit-and-fissure sealants when associated with primary teeth as counterbody, restricting the involved variables. The aim of this study was to evaluate wear of dental materials used as pit-and-fissure sealants in contact with primary teeth. Materials and Methods: A resinous sealant (Fluroshield®) and a resin-modified glass ionomer cement (Vitremer®) were selected in a post-plate design, using as counterbody primary tooth pins (4 × 4 × 2 mm) at 3 and 10 N vertical load, 1 Hz frequency, 900 wear cycles in artificial saliva (n = 15). Attrition coefficient values were obtained and the material and primary tooth volumes were analyzed. Data were analyzed statistically by ANOVA and Duncan's test (P < 0.05). Results: Fluroshield® presented the highest attrition coefficient values for the 3 N but these values decreased significantly for the 10 N load. The means for volume loss (3 mm) of the different samples after the wear test were not statistically different for the materials. The volume loss values for the primary teeth were statistically different and there was an increase in volume loss with the increase of the load applied in the wear tests. Conclusions: Differences were also observed with regard to the surface deformation characteristics. The wear rates of primary tooth enamel vary according to the type of material and the load applied during mastication. PMID:24966777

  4. Influence of etching time and bonding strategies on the microshear bond strength of self- and light-cured pit-and-fissure sealants.

    PubMed

    Souza-Junior, Eduardo José; Borges, Boniek Castillo Dutra; Montes, Marcos Antônio Japiassú Resende; Alonso, Roberta Caroline Bruschi; Ambrosano, Glaucia Maria Bovi; Sinhoreti, Mário Alexandre Coelho

    2012-01-01

    This study evaluated the impact of extended etching and bonding strategies on the microshear bond strength of three sealant materials. Two pit-and-fissure sealants [FluroShield, Dentsply (light-cured) and AlphaSeal, DFL (self-cured)] and one light-cured flowable composite resin (Permaflo, Ultradent) were evaluated according to different enamel etching times (15 s or 30 s) and bonding procedures (no adhesive application, application of primer/hydrophobic resin or hydrophobic resin only). Intact enamel blocks were obtained from bovine teeth and sealed via the tested protocols. After 24 h, the microshear bond strength test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were classified by stereomicroscopy. Data were submitted to a three-way ANOVA and to Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) among the materials. Permaflo showed higher bond strength when etched for 30 s alone. Enamel overetching decreased the bond strength of the light-cured sealant. Primer/bond previous treatment improved bond performance for AlphaSeal. In conclusion, from the tested conditions, all sealant materials presented similar bond strength values in relation to bonding protocol and etching time. The flowable composite can be used as a pit-and-fissure sealant. The use of a three-step adhesive system was essential for the self-cured sealant application.

  5. [Development of elastameric sealant designed for arterial field].

    PubMed

    Matsuda, Takehisa; Nakajima, Nobuyuki

    2013-04-01

    The development of a reliable surgical sealant specific for arterial tissues has been long awaited. In this article, first the "ideal" adhesion mechanism formulated from biomechanical concept is proposed for ensured hemostasis in dissected arteries with pulsatile flow. An urethane prepolymer prepared along the design criteria is viscous liquid. Due to its high water absorbility and high reactivity with water, the sealant applied to vascular tissues becomes an elastomer within several minutes. When the sealant was applied to dissected canine abdominal arteries with 3 stay sutures, followed by declamping 5 minutes, neither bleeding nor detrimental effect on tissue morphogenesis was observed. This sealant is being ready to the market.

  6. Development of the crack sealant adhesion test.

    DOT National Transportation Integrated Search

    2009-04-01

    Crack sealants are widely used in Texas to prevent water from entering into lower structural layers thereby : extending pavement life. However, most current crack sealants have been reported to have a very short life mainly due : to adhesive failures...

  7. Sealant retention is better assessed through colour photographs than through the replica and the visual examination methods.

    PubMed

    Hu, Xuan; Fan, Mingwan; Rong, Wensheng; Lo, Edward C M; Bronkhorst, Ewald; Frencken, Jo E

    2014-08-01

    The aim of this study was to test the hypothesis that the colour photograph method has a higher level of validity for assessing sealant retention than the visual clinical examination and replica methods. Sealed molars were assessed by two evaluators. The scores for the three methods were compared against consensus scores derived through assessing retention from scanning electron microscopy images (reference standard). The presence/absence (survival) of retained sealants on occlusal surfaces was determined according to the traditional and modified categorizations of retention. Sensitivity, specificity, and Youden-index scores were calculated. Sealant retention assessment scores for visual clinical examinations and for colour photographs were compared with those of the reference standard on 95 surfaces, and sealant retention assessment scores for replicas were compared with those of the reference standard on 33 surfaces. The highest mean Youden-index score for the presence/absence of sealant material was observed for the colour photograph method, followed by that for the replica method; the visual clinical examination method scored lowest. The mean Youden-index score for the survival of retained sealants was highest for the colour photograph method for both the traditional (0.882) and the modified (0.768) categories of sealant retention, whilst the visual clinical examination method had the lowest Youden-index score for these categories (0.745 and 0.063, respectively). The colour photograph method had a higher validity than the replica and the visual examination methods for assessing sealant retention. © 2014 Eur J Oral Sci.

  8. An in-vitro evaluation of mechanical and esthetic properties of orthodontic sealants

    PubMed Central

    Premaraj, Thyagaseely Sheela; Rohani, Nima; Covey, David; Premaraj, Sundaralingam; Hua, Yi; Watanabe, Hidehiko

    2014-01-01

    Objective: To evaluate mechanical and esthetic Properties of two commercially available orthodontic sealants: Opal®Seal (OS) and L.E.D. Pro Seal (PS). Materials and Methods: Discs of each sealant were prepared to test the following properties: Micro hardness, wear resistance and color stability. Samples were randomly selected after the wear test for SEM imaging to analyze surface morphology. Results: OS was significantly harder than PS (P < 0.001). PS was significantly more wear resistant than OS (P < 0.05). PS showed a greater ∆E*ab (increased staining) when placed in wine or coffee showing a significant difference (P < 0.05). SEM showed particle size, shape and distribution were different for PS and OS reflecting the pattern seen on wear surfaces. Conclusion: Both orthodontic sealants are beneficial for protecting enamel. However with better wear properties PS was superior in resisting mechanical stresses. OS was more color stable. PMID:25512729

  9. Dental sealants and flowable composite restorations and psychosocial, neuropsychological, and physical development in children.

    PubMed

    Maserejian, Nancy N; Shrader, Peter; Trachtenberg, Felicia L; Hauser, Russ; Bellinger, David C; Tavares, Mary

    2014-01-01

    Dental sealant materials may intraorally release their components, including bisphenol-A (BPA), but long-term health effects are uncertain. The New England Children's Amalgam Trial (NECAT) found that composite restorations were associated with psychosocial, but not neuropsychological or physical, outcomes. The previous analysis did not consider sealants and preventive resin restorations (PRRs), which were routinely placed. The purpose of this analysis was to examine sealant/PRR exposure in association with psychosocial and other health outcomes. NECAT recruited 534 six- to 10-year-olds and provided dental care during a five-year follow-up. Annually, examiners conducted psychosocial and neuropsychological tests and measured body mass index (BMI) and fat percentage (BF%). Associations between surface years (SY) of sealants/PRRs and outcomes were tested using multivariable models. Cumulative exposure level to sealants and/or PRRs was not associated with psychosocial assessments (eg, total problems: Child Behavior Checklist, 10-SY β=-0.2 ± 0.3, P=.60) or neuropsychological tests (eg, full-scale IQ, 10-SY β=0.1 ± 0.2, P=.60). There were no associations for changes in BMI-for-age z-score (P=.40), BF% (girls 10-SY β=-0.2 ± 0.3; boys 10-SY β=-0.1 ± 0.3), or menarche (10-SY hazard ratio=0.91, 95% confidence interval=0.83-1.01, P=.08). This study showed no associations between exposure level of dental sealants or PRRs and behavioral, neuropsychological, or physical development in children over 5-years.

  10. Fibrin Sealants in Dura Sealing: A Systematic Literature Review

    PubMed Central

    2016-01-01

    Background Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. Methods A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. Results A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or

  11. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.

    PubMed

    Esposito, Felice; Angileri, Filippo Flavio; Kruse, Peter; Cavallo, Luigi Maria; Solari, Domenico; Esposito, Vincenzo; Tomasello, Francesco; Cappabianca, Paolo

    2016-01-01

    Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or powered to demonstrate a

  12. Microleakage of self-etching sealant on noncontaminated and saliva-contaminated enamel.

    PubMed

    2011-01-01

    The purpose of this study was to compare the microleakage of a self-etching sealant with a traditional phosphoric acid-etched sealant under noncontaminated and saliva-contaminated conditions. Fifty-two sound extracted human molars were randomly divided into 4 groups (N=13). Teeth in Groups 1 and 2 were cleaned with pumice, etched with phosphoric acid, rinsed, coated with a drying agent, placed with sealants (UltraSeal XT Plus), and light cured. Teeth in Groups 3 and 4 were cleaned with a proprietary flour pumice and rinsed prior to being sealed with a self-etching sealant (Enamel Loc). Teeth in Groups 2 and 4 were contaminated with saliva and thoroughly air-dried prior to the sealant placement. All teeth were subjected to a thermocycling process, stained with silver nitrate, and sectioned, and images of the sealant on the occlusal surface were recorded. Microleakage distance was measured in millimeters and subjected to a 2-way analysis of variance. Significantly larger microleakage distances were found for the self-etching sealant vs the traditional sealant (P<.001). Saliva contamination did not significantly affect the microleakage distance (P<.17). Under the conditions used in this in vitro study, the self-etching sealant, regardless of contamination condition, had extensive microleakage distances vs. little microleakage in the traditional phosphoric acid-etched sealant.

  13. Is fibrin sealant effective and safe in total knee arthroplasty? A meta-analysis of randomized trials

    PubMed Central

    2014-01-01

    The objective of this study was to evaluate the efficacy and safety of fibrin sealant in patients following total knee arthroplasty (TKA). A comprehensive literature search of the electronic databases PubMed, MEDLINE, Web of Science, and Cochrane Library for published randomized controlled trials (RCTs) was undertaken. The evidence base was critically appraised using a tool from the Cochrane Bone, Joint and Muscle Trauma Group. Eight RCTs involving 641 patients were included. The use of fibrin sealant significantly reduced postoperative drainage (weighted mean difference (WMD) −346, 95% confidence interval (CI) −496.29 to −197.54, P < 0.00001) and blood transfusions (risk ratio (RR) 0.47, 95% CI 0.35 to 0.63, P < 0.00001) and led to a significant improvement in the range of motion (WMD 16.59, 95% CI 6.92 to 26.25, P = 0.0008). However, using fibrin sealant did not significantly reduced total blood loss (WMD −305.25, 95% CI −679.44 to 68.95, P = 0.11). Regarding complications, there were no significant differences in any adverse events, fever, infection, or hematoma among the study groups. In conclusion, the present meta-analysis indicates that the use of fibrin sealant was effective and safe as a hemostatic therapy for patients with TKA. PMID:24884626

  14. Stress analyses for the glass joints of contemporary sodium sulfur batteries

    NASA Astrophysics Data System (ADS)

    Jung, Keeyoung; Lee, Solki; Kim, Goun; Kim, Chang-Soo

    2014-12-01

    During the manufacturing and thermal cycles of advanced contemporary large sized sodium sulfur (NaS) batteries, thermally driven stresses can be applied to the glass sealing joints, which may result in catastrophic cell failure. To minimize the thermal stresses at the joints, there is a need to develop a method to properly estimate the maximum thermal stresses by varying the materials properties and shapes of the sealing area, and thereby determine the properties and shapes of sealing material at the joints. In the present study, the optimum coefficient of thermal expansion (CTE) of the glass sealant and end shape of the glass sealing area (i.e., concave, flat, and convex shapes) have been determined using the finite-element analysis (FEA) computation technique. The results showed that the CTE value of 7.8 × 10-6 K-1 with a convex end shape would have the lowest stress concentration in the vicinity of glass sealing joints for the prototype tubular NaS cell design adopted in this work.

  15. Hemostats, sealants, and adhesives: components of the surgical toolbox.

    PubMed

    Spotnitz, William D; Burks, Sandra

    2008-07-01

    The surgical toolbox is expanding, and newer products are being developed to improve results. Reducing blood loss so that bloodless surgery can be performed may help minimize morbidity and length of stay. As patients, hospital administrators, and government regulators desire less invasive procedures, the surgical technical challenge is increasing. More operations are being performed through minimally invasive incisions with laparoscopic, endoscopic, and robotic approaches. In this setting, tools that can reduce bleeding by causing blood to clot, sealing vessels, or gluing tissues are gaining an increasing importance. Thus, hemostats, sealants, and adhesives are becoming a more important element of surgical practice. This review is designed to facilitate the reader's basic knowledge of these tools so that informed choices are made for controlling bleeding in specific clinical situations. Such information is useful for all members of the operative team. The team includes surgeons, anesthesiologists, residents, and nurses as well as hematologists and other medical specialists who may be involved in the perioperative care of surgical patients. An understanding of these therapeutic options may also be helpful to the transfusion service. In some cases, these materials may be stored in the blood bank, and their appropriate use may reduce demand for other transfusion components. The product classification used in this review includes hemostats as represented by product categories that include mechanical agents, active agents, flowables, and fibrin sealants; sealants as represented by fibrin sealants and polyethylene glycol hydrogels; and adhesives as represented by cyanoacrylates and albumin cross-linked with glutaraldehyde. Only those agents approved by the Food and Drug Administration (FDA) and presently available (February 2008) for sale in the United States are discussed in this review.

  16. Experimental Investigation of Bio-Sealants Used for Pavement Preservation and Development of a New Strength Test for Asphalt Binders at Low Temperature

    NASA Astrophysics Data System (ADS)

    Ghosh, Debaroti

    Surface treatment using sealants as a mean of pavement preservation is an important tool for cost-effectively extending service life of pavement. Sealants have become an important tool for cost-effectively extending the service life pavements. Due to the combined negative effects of asphalt aging and thermal cracking, it is always more challenging to choose an appropriate preservation technique for pavements built in cold-regions. Asphalt aging and thermal cracking negatively affect pavements built in cold climates. Therefore, it is important to evaluate the effects of sealants in laboratory conditions before application in the field to ensure effective performance. However, preservation activities cannot effectively address major distresses, such as low-temperature cracking, that can occur when the pavement was built from the very beginning with less durable materials. Therefore, an essential requirement to mitigate low-temperature cracking of pavements for asphalt materials used in the construction of pavement built in cold- regions is ensuring proper fracture properties of the asphalt materials used in construction. This study has two parts. In the first part, a laboratory evaluation of the effects of adding bio-sealants to both asphalt binder and mixture is performed. The goal is to obtain relevant properties of treated asphalt materials to understand the mechanism by which sealants improve pavement performance. For asphalt binders, a dynamic shear rheometer and a bending beam rheometer were used to obtain rheological properties of treated and untreated asphalt binders. For asphalt mixtures, field cores from both untreated and treated sections were collected and thin beam specimens were prepared from the cores to compare the creep and strength properties of the field-treated and laboratory-treated mixture. It is observed that the oil-based sealants have a significant softening effect on the control binder compared to the water-based sealant and traditional

  17. Systematic review on the use of matrix-bound sealants in pancreatic resection.

    PubMed

    Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus

    2015-11-01

    Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. © 2015 International Hepato-Pancreato-Biliary Association.

  18. Factors associated with sealant outcome in 2 pediatric dental clinics: a multivariate hierarchical analysis.

    PubMed

    West, Nathan G; Ilief-Ala, Melina A; Douglass, Joanna M; Hagadorn, James I

    2011-01-01

    This study's purpose was to determine whether one-time sealants placed by pediatric dental residents vs dental students have different outcomes. The effect of isolation technique, behavior, duration of follow-up, and caries history was also examined. Records from 2 inner-city pediatric dental clinics were audited for 6- to 10-year-old patients with a permanent first molar sealant with at least 2 years of follow-up. A successful sealant was a one-time sealant that received no further treatment and was sealed or unsealed but not carious or restored at the final audit. Charts from 203 children with 481 sealants were audited. Of these, 281 sealants were failures. Univariate analysis revealed longer follow-up and younger age were associated with sealant failure. Operator type, child behavior, and isolation technique were not associated with sealant failure. After adjusting for follow-up duration, increased age at treatment reduced the odds of sealant failure while a history of caries reduced the protective effect of increased age. After adjusting for these factors, practitioner type, behavior, and type of isolation were not associated with sealant outcome in multivariate analysis. Age at sealant placement, history of caries prior to placement, and longer duration of follow-up are associated with sealant failure.

  19. Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  20. Development of new photopolymerizable dental sealants.

    PubMed

    Davidenko, N; Cohen, M E; Diaz, J M; Sastre, R

    1998-01-01

    This paper describes the results obtained in the optimization of the composition of dental sealants in relation to the nature and proportions of monomer mixtures and photoinitiating system employed. The quantification and variation of certain parameters which determine the quality of a dental sealant (such as viscosity and penetrating power, residual double bonds, solubility and absorption, volume shrinkage and certain specific mechanical properties) have resulted in the development of new formulations. The composition which has achieved the best results of all the above properties was that corresponding to the monomer mixture bis-GMA/tri(ethylene glycol) dimethacrylate (TEGDMA) 40/60 wt%, and the photoinitiating system camphorquinone (CQ) with co-initiators N,N,3,5-tetramethyaniline (TMA) or N,N-dimethyl-p-toluidine (DMPT) in the ratio 1:1. The final properties and characteristics of the obtained formulations are superior to those of commercial dental sealants currently in use.

  1. In vitro comparison of two widely used surgical sealants for treating alveolar air leak.

    PubMed

    Zhang, Ruoyu; Bures, Maximilian; Höffler, Klaus; Jonigk, Danny; Haverich, Axel; Krueger, Marcus

    2014-12-01

    Controversies surrounding the efficacy of sealants against alveolar air leak (AAL) are abundant in the literature. We sought to test the widely used sealants, TachoSil (Takeda Pharmaceutical Company Limited, Osaka, Japan) and BioGlue (CryoLife Europa Ltd., Surrey, United Kingdom) in an in vitro model. Materials and After creation of a focal superficial defect (40 × 25 mm) in swine lungs (n=40), AAL was assessed with increasing inspired tidal volume (TVi). Upon sealant application in a randomized order, AAL was assessed in the same way until sealant burst. At TVi =400, 500, 600, and 700 mL, BioGlue achieved sealing in 19, 19, 16, and 14 tests, while TachoSil sealed in 19, 14, 4, and no test, respectively. The maximally tolerated pressure of BioGlue was higher than TachoSil (40.3 ± 3.0 vs. 36.0 ± 4.9 cm H2O, p=0.003). Cohesive and adhesive failures were found in 10 and 1 tests of BioGlue, respectively, while all burst failures of TachoSil were adhesive. Concerning elasticity, TachoSil allowed more expansion of the covered defect than BioGlue (6.3 ± 3.9 vs. 1.4 ± 1.0 mm, p<0.001). The tested sealants demonstrated high sealing efficacy. While BioGlue was superior in resisting higher ventilation pressure, TachoSil possessed better elasticity. Georg Thieme Verlag KG Stuttgart · New York.

  2. Systematic review on the use of matrix-bound sealants in pancreatic resection

    PubMed Central

    Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus

    2015-01-01

    Background Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. Methods A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Results Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). Conclusions The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. PMID:26292846

  3. Use of fibrin sealants in cardiovascular surgery: a systematic review.

    PubMed

    Rousou, John A

    2013-05-01

    Fibrin sealants are used for hemostasis and tissue adherence. This systematic review summarizes published clinical data for fibrin sealant use in cardiovascular surgery. A literature search for the following terms was conducted using PubMed and EMBASE: (TISSEEL or Tissucol or Beriplast P or Evicel or Quixil or Crosseal or Reliseal or Fibringluraas or Bolheal or Tachosil or Vivostat or Vitagel or Artiss or "fibrin glue" or "fibrin sealant" or "fibrin tissue adhesive") and (cardiac or cardiovascular or vascular or heart or coronary or surgery). Case reports and series were excluded; although reports of controlled trials were preferred, uncontrolled trial data were also considered. Clinical trials and chart review analyses of fibrin sealants were identified and summarized. Although clinical trial data were available for other agents, the majority of published studies examined TISSEEL. Overall, TISSEEL and other fibrin sealants showed improvements over standard of care or control groups for a variety of predefined endpoints. Safety findings are also summarized. Data from these studies showed that fibrin sealants were well tolerated and provided effective hemostasis in a range of cardiac and aortic surgeries. © 2013 Wiley Periodicals, Inc.

  4. Development of a Novel Alginate-Based Pleural Sealant

    DTIC Science & Technology

    2017-09-01

    and will be the subject of ongoing studies . Figure 20: Experimental set-up for endobronchial administration of sealants in the ex vivo pig lung...toxicity. In the studies to date, we have done extensive materials characterization not just of modified alginates but now a number of other biologic...pig) ex vivo lung models and have performed initial in vivo evaluations of several compounds in a non-survival surgery rat lung injury model. The

  5. Tensile strength of biological fibrin sealants: a comparative study.

    PubMed

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. ART restorations and sealants placed in Chinese school children--results after three years.

    PubMed

    Holmgren, C J; Lo, E C; Hu, D; Wan, H

    2000-08-01

    These were to assess whether ART restorations and sealants could be provided to children in a school environment in China, to assess patient acceptability of the ART approach, and to evaluate on a longitudinal basis the treatments performed. This study was conducted in Deyang, Sichuan Province, in western China. A total of 294 ART restorations were placed in 197 children and 191 fissure sealants were placed in 140 children by five middle-level dentists in four secondary schools. Standard instruments and procedures for ART were used. The restorative material used was a high-strength glass-ionomer (Ketac-Molar, ESPE). The treatments were evaluated annually after placement by the same examiner who had not been involved in the placement of the restorations nor sealants using explorers and mouth-mirrors. At the 3-year examination an independent external examiner evaluated the restorations using USPHS criteria. Most of the children did not report discomfort during treatment and 92% were willing to receive ART restorations again. The cumulative 1-year and 3-year survival rates of small Class I restorations were 99% and 92% respectively. The corresponding figures for large Class I restorations were 90% and 77%. After 3 years, 72% of the sealants were either partially or completely retained. Only 2% of the sealed teeth developed fissure caries and these involved teeth where the sealants had been lost. Similar success rates were found using USPHS criteria. The ART approach for preventing and treating tooth decay in Chinese school children was shown to be appropriate, effective and acceptable. The 3-year survival rates of the restorations were high but were related to the size and type of the restoration.

  7. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel

    PubMed Central

    Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    Background The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. Material and Methods A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p<0.05. Results There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. Conclusions The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words:Pit and fissure sealant, Universal adhesive, Saliva. PMID:29670708

  8. Effect of sealant agents on the color stability and surface roughness of nanohybrid composite resins.

    PubMed

    Dede, Doğu Ömür; Şahin, Onur; Koroglu, Aysegül; Yilmaz, Burak

    2016-07-01

    The effect of sealant agents on the surface roughness and color stability of nanohybrid composite resins is unknown. The purpose of this in vitro study was to evaluate the effect of sealant agents on the surface roughness and color stability of 4 nanohybrid composite resin materials. Forty disks (10×2 mm) were fabricated for each nanohybrid composite resin material (Z-550, Tetric EvoCeram, Clearfill Majesty, Ice) (N=160) and divided into 4 surface treatment groups: 1 conventional polishing (control) and 3 different sealant agent (Palaseal, Optiglaze, BisCover) coupling groups (n=10). The specimens were thermocycled, and surface roughness (Ra) values were obtained with a profilometer. Scanning electron microscope images were also recorded. CIELab color parameters of each specimen were measured with a spectrophotometer before and after 7 days of storage in a coffee solution. Color differences were calculated by the CIEDE 2000 (ΔE00) formula. The data were statistically analyzed by 2-way ANOVA and by the Tukey HSD test (α=.05). The surface treatment technique significantly affected the Ra values of the composite resins tested (P<.001). The interaction between the surface treatment technique and composite resin material was also significant for ΔE00 values (P<.05). Within the composite resin groups, significant decreases in Ra were observed only for the Palaseal agent coupled composite resin groups (except Ice) compared with the control groups (P<.05). Scanning electron microscope images revealed rougher surfaces with conventionally polished groups compared with test groups. Conventionally polished groups had the highest ΔE00 (3.09 to 3.49) values for each composite resin group, except for BisCover applied Clearfill Majesty (P<.05). Within the composite resin groups, significant differences were observed between the color change seen with BisCover and other sealants for Clearfill Majesty composite resin (P<.05). Using Palaseal agent on all tested composite

  9. Evaluation of a hydrophilic gingival dental sealant in beagle dogs.

    PubMed

    Sitzman, Clarence

    2013-01-01

    A liquid solution, gingival sealant containing polymers that form a barrier film upon application was evaluated in dogs. It is a non-toxic, low viscosity, hydrophilic barrier sealant that dries in approximately 10 to 15-seconds after subgingival application. It was designed as a preventative to be applied immediately following a professional oral hygiene procedure in order to block plaque and calculus formation in the sulcus and aid in the prevention of periodontal disease in companion animals. Additionally, the polymer was designed to promote an aerobic environment in the sulcus by oxygen and water transport through engineered pores within the polymer. A 30-day split-mouth, blinded study in two groups of 15 beagle dogs was used. Plaque was significantly (p < 0.05) reduced on the side receiving the sealant by 30.0% and 50.5% (average = 40.3%) in groups 1 and 2, respectively. Calculus was significantly (p < 0.05) reduced on the side receiving the sealant by 27.2% and 20.0% (average = 23.6%) in groups 1 and 2, respectively. Gingival inflammation was monitored to assess product safety. Sides receiving sealant showed no statistically significant differences in gingival index score. No adverse events were observed in the study. This study demonstrates that this gingival sealant can be used as another valuable tool for aiding in the prevention of periodontal disease in dogs.

  10. Monitoring Sealant Durability during Instrumented Outdoor Exposure with Variation in Prestrain

    Treesearch

    Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt

    2015-01-01

    Sealants are a vital part of a building’s environmental barrier envelope. Their ability to bond to numerous dissimilar substrates and form cure-in-place seals results in their widespread use throughout single story and high rise buildings. A typical 40 story concrete and glass facade building can have 70 miles of sealant bonds. Failure of sealants can lead to energy...

  11. Reimbursement rates and policies for primary molar pit-and-fissure sealants across state Medicaid programs.

    PubMed

    Chi, Donald L; Singh, Jennifer

    2013-11-01

    Little is known about Medicaid policies regarding reimbursement for placement of sealants on primary molars. The authors identified Medicaid programs that reimbursed dentists for placing primary molar sealants and hypothesized that these programs had higher reimbursement rates than did state programs that did not reimburse for primary molar sealants. The authors obtained Medicaid reimbursement data from online fee schedules and determined whether each state Medicaid program reimbursed for primary molar sealants (no or yes). The outcome measure was the reimbursement rate for permanent tooth sealants (calculated in 2012 U.S. dollars). The authors compared mean reimbursement rates by using the t test (α = .05). Seventeen Medicaid programs reimbursed dentists for placing primary molar sealants (34 percent), and the mean reimbursement rate was $27.57 (range, $16.00 [Maine] to $49.68 [Alaska]). All 50 programs reimbursed dentists for placement of sealants on permanent teeth. The mean reimbursement for permanent tooth sealants was significantly higher in programs that reimbursed for primary molar sealants than in programs that did not ($28.51 and $23.67, respectively; P = .03). Most state Medicaid programs do not reimburse dentists for placing sealants on primary molars, but programs that do so have significantly higher reimbursement rates. Medicaid reimbursement rates are related to dentists' participation in Medicaid and children's dental care use. Reimbursement for placement of sealants on primary molars is a proxy for Medicaid program generosity.

  12. Prevalence of Dental Caries and Fissure Sealants in a Portuguese Sample of Adolescents

    PubMed Central

    Veiga, Nélio J.; Pereira, Carlos M.; Ferreira, Paula C.; Correia, Ilidio J.

    2015-01-01

    Introduction The aims of this study were to assess the prevalence of dental caries and the DMFT index, as well as the distribution pattern of pit and fissure sealants on permanent teeth in a Portuguese sample of adolescents, and to assess whether the existing usage of sealants and socio-demographic factors are correlated to caries prevalence on the examined sample. Materials and Methods A cross-sectional study was designed with a sample of 447 adolescents aged 12 to 18 years old, attending a public school in Sátão, Portugal. A self-administered questionnaire with questions about oral health behaviours and socio-economic status was answered by adolescents in the classroom. Clinical examination of oral health status and assessment of fissure sealants were accomplished by only one trained member of the research team. Results We obtained a DMFT index of 3.32 (2.92), which indicates a moderate level of prevalence of dental caries. When considering a DMFT = 0, we found significant statistical differences between the parents´ level of education (≤ 4th grade = 26.3 vs 5th–12th grade = 18.8 vs <12th grade = 43.3, p = 0.001), gender (male = 27.3 vs female = 19.6, p = 0.04), age (≤15 years = 27.1 vs <15 years = 18.5, p = 0.02), presence of fissure sealants (yes = 30.6 vs no = 13.5, p = 0.001) and experience of dental pain (no = 25.4 vs yes = 16.8, p = 0.02). When analyzing the prevalence of fissure sealants, we verified that 58.8% of adolescents had at least one fissure sealant applied. Significant statistical differences were found when analyzing the presence of fissure sealants related with parents´educational level (<9th grade, OR = 1.56 CI95% = 1.05–2.54), gender (female, OR = 1.86 CI95% = 1.19–2.98), experience of dental pain (yes, OR = 0.62 CI95% = 0.39–0.97) and presence of dental caries (yes, OR = 0.35 CI95% = 0.19–0.65). Conclusions The moderate level of caries prevalence reveals the need of improvement of primary prevention interventions among

  13. An investigation into sealant restoration usage in general dental practice in England.

    PubMed

    Hassall, D C; Mellor, A C

    2001-10-13

    A study was undertaken to investigate attitudes to sealant restorations and their usage in general dental practice in England. Seventy three dentists in three areas (Doncaster, Hereford/Worcester and Wycombe) provided retrospective details of treatment provided over a one year period for 4,250 6-12 and 13-15 year old subjects. Fifty nine of these dentists then completed a telephone questionnaire relating to their treatment patterns and attitudes to sealant restorations. The treatment data indicated that only 59 of the 4,250 children received a sealant restoration during the study period. Of the 44 dentists who claimed in the questionnaire to be using sealant restorations, only 28 had placed them in their selected patients. Positive attitudes to sealant restorations were expressed but also concerns that may be prejudicing usage.

  14. Effect of fibrin sealant in positioning and stabilizing microvascular pedicle: A comparative study.

    PubMed

    Kim, Jeong Tae; Kim, Youn Hwan; Kim, Sang Wha

    2017-07-01

    Fibrin sealants have had applications in hemostasis, cohesion, and promotion of healing in plastic surgery. In this article, we review cases where fibrin sealant was used to stabilize microvascular pedicles and compared with previous free flaps performed without fibrin sealant. Between 2008 and 2010, 62 consecutive patients underwent free tissue transfer for reconstruction; this involved 33 latissimus dorsi perforator flaps, 14 thoracodorsal artery perforator flaps, 9 latissimus dorsi myocutaneous flaps, 3 lateral thoracic artery perforator flaps, and 3 transverse rectus abdominis myocutaneous flaps, used in head and neck reconstruction, lower limb reconstructions, breast reconstructions, and facial palsy reconstruction. Following microvascular anastomosis, the microvascular pedicles were placed in the optimal position, and fibrin sealant was used to fix and stabilize them. The complications, such as venous thrombosis, arterial thrombosis, hematoma, and vascular pedicle kinking, were compared with that of 672 previous free flaps without fibrin sealant for stabilizing microvascular pedicles. Among the 62 free tissue transfers using fibrin sealant, there was only one complication involving flap failure (1.6%), in this case due to venous thrombosis. Analysis of 672 free flaps performed without application of fibrin sealant revealed 24 complications (3.6%), due to 3 venous thrombosis, 1 arterial thrombosis, 4 vascular pedicel compression due to hematoma, and 16 pedicle kinking. However, the comparison of complications between the free flap using fibrin sealant and the free flap without fibrin sealant were not statistically significant (P = 0.65). Fibrin sealant can be used to prevent vascular kinking and to position anastomosed vessels after successful micro-anastomosis and allow the reconstructive surgeon to overcome challenging situations of vascular pedicle related complications © 2016 Wiley Periodicals, Inc. Microsurgery 37:406-409, 2017. © 2016 Wiley

  15. CAUSES OF POOR SEALANT PERFORMANCE IN SOIL-GAS- RESISTANT FOUNDATIONS

    EPA Science Inventory

    The paper discusses causes of poor sealant performance in soil-gas-resistant foundations. ealants for radon-resistant foundation construction must seal the gap between concrete sections. odern sealants have such low permeability that seal performance depends only on the permeabil...

  16. Collector sealants and breathing. Final Report, 25 September 1978-31 December 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendelsohn, M A; Luck, R M; Yeoman, F A

    1980-02-20

    The objectives of this program were: (1) to investigate the pertinent properties of a variety of possible sealants for solar collectors and identify the most promising candidates, and (2) to study the effect of breathing in flat-plate, thermal solar collector units. The study involved two types of sealants, Class PS which includes preformed seals or gaskets and Class SC which includes sealing compounds or caulks. It was the intent of the study to obtain data regarding initial properties of candidate elastomers from manufacturers and from the technical literature and to use those sources to provide data pertaining to endurance ofmore » these materials under environmental service conditions. Where necessary, these data were augmented by experimental measurements. Environmental stresses evaluated by these measurements included elevated temperatures, moisture, ultraviolet light, ozone and oxygen, and fungus. The second major area of the work involved a study of the effects of materials used and design on the durability of solar collectors. Factors such as design, fabrication, materials of construction, seals and sealing techniques and absorber plate coatings were observed on actual field units removed from service. Such phenomena as leakage, corrosion and formation of deposits on glazing and absorber plate were noted. An evaluation of the properties of several desiccants was made in order to providemeans to mitigate the deleterious effects of water on collector life. Adsorbents for organic degradation products of sealants were also investigated in order to protect the glazing and absorber plate from deposited coatings. Since adsorbents and desiccants in general tend to take up both water and organic decomposition products, relative affinities of a number of these agents for water and for organic compounds were determined . Results are presented in detail.« less

  17. Compliant sealants for solid oxide fuel cells and other ceramics

    DOEpatents

    Bloom, I.D.; Ley, K.L.

    1995-09-26

    A glass or glass-ceramic sealant is described for a SOFC having a coefficient of thermal expansion in the range of from about 8 to about 13{times}10{sup {minus}6}/C and a viscosity of at least 10{sup 3}Pa-s at cell operating temperature. The sealant has a composition of SrO present in the range of from about 5 to about 60 mole percent, La{sub 2}O{sub 3} present in the range of from 0 to about 45 mole percent, Al{sub 2}O{sub 3} present in the range from 0 to about 15 mole percent, B{sub 2}O{sub 3} present in the range of from about 15 mole percent to about 80 mole percent, and SiO{sub 2} present in the range of from 0 to about 40 mole percent, wherein the material is a viscous fluid at cell operating temperatures of from about 600 C to about 1000 C. The sealant may also be compounds of CaO present in the range of from 0 to about 35 mole percent, Al{sub 2}O{sub 3} present in the range from 0 to about 15 mole percent, B{sub 2}O{sub 3} present in the range of from about 35 mole percent to about 85 mole percent, and SiO{sub 2} present in the range of from 0 to about 30 mole percent. 2 figs.

  18. Compliant sealants for solid oxide fuel cells and other ceramics

    DOEpatents

    Bloom, Ira D.; Ley, Kevin L.

    1995-01-01

    A glass or glass-ceramic sealant for a SOFC having a coefficient of thermal expansion in the range of from about 8 to about 13.times.10.sup.-6 /.degree.C. and a viscosity of at least 10.sup.3 Pa-s at cell operating temperature. The sealant has a composition of SrO present in the range of from about 5 to about 60 mole percent, La.sub.2 O.sub.3 present in the range of from 0 to about 45 mole percent, Al.sub.2 O.sub.3 present in the range from 0 to about 15 mole percent, B.sub.2 O.sub.3 present in the range of from about 15 mole percent to about 80 mole percent, and SiO.sub.2 present in the range of from 0 to about 40 mole percent, wherein the material is a viscous fluid at cell operating temperatures of from about 600.degree. C. to about 1000.degree. C. The sealant may also be compounds of CaO present in the range of from 0 to about 35 mole percent, Al.sub.2 O.sub.3 present in the range from 0 to about 15 mole percent, B.sub.2 O.sub.3 present in the range of from about 35 mole percent to about 85 mole percent, and SiO.sub.2 present in the range of from 0 to about 30 mole percent.

  19. Ohio Route 50 joint sealant experiment : research implementation plan.

    DOT National Transportation Integrated Search

    2005-05-01

    Research in the state of Wisconsin over the past forty years has found no noticeable difference in : performance between jointed concrete pavement (JCP) constructed with a sealed contraction joint and : JCP constructed with a single, narrow, unsealed...

  20. Vital Signs: Dental Sealant Use and Untreated Tooth Decay Among U.S. School-Aged Children.

    PubMed

    Griffin, Susan O; Wei, Liang; Gooch, Barbara F; Weno, Katherine; Espinoza, Lorena

    2016-10-21

    Tooth decay is one of the greatest unmet treatment needs among children. Pain and suffering associated with untreated dental disease can lead to problems with eating, speaking, and learning. School-based dental sealant programs (SBSP) deliver a highly effective intervention to prevent tooth decay in children who might not receive regular dental care. SBSPs benefits exceed their costs when they target children at high risk for tooth decay. CDC used data from the National Health and Nutrition Examination Survey (NHANES) 2011-2014 to estimate current prevalences of sealant use and untreated tooth decay among low-income (≤185% of federal poverty level) and higher-income children aged 6-11 years and compared these estimates with 1999-2004 NHANES data. The mean number of decayed and filled first molars (DFFM) was estimated for children with and without sealants. Averted tooth decay resulting from increasing sealant use prevalence was also estimated. All reported differences are significant at p<0.05. From 1999-2004 to 2011-2014, among low- and higher-income children, sealant use prevalence increased by 16.2 and 8.8 percentage points to 38.7% and 47.8%, respectively. Among low-income children aged 7-11 years, the mean DFFM was almost three times higher among children without sealants (0.82) than among children with sealants. Approximately 6.5 million low-income children could potentially benefit from the delivery of sealants through SBSP. The prevalence of dental sealant use has increased; however, most children have not received sealants. Increasing sealant use prevalence could substantially reduce untreated decay, associated problems, and dental treatment costs.

  1. A comparison of the effects of toothbrushing and handpiece prophylaxis on retention of sealants.

    PubMed

    Kolavic Gray, Shellie; Griffin, Susan O; Malvitz, Dolores M; Gooch, Barbara F

    2009-01-01

    Tooth surface cleaning before acid etching is considered to be an important step in the retention of resin-based pit-and-fissure sealants. The authors reviewed and summarized instructions for cleaning tooth surfaces from five manufacturers of 10 unfilled resin-based sealants marketed in the United States. The authors also searched electronic databases for studies that directly compared the effects of different surface-cleaning methods on sealant retention and for systematic reviews of the effectiveness of sealants. They explored the association between surface-cleaning methods and sealant retention in the studies included in the systematic reviews. They calculated the summary weighted retention rates for studies that used either a handpiece or toothbrush prophylaxis. All of the sealant manufacturers' instructions for use (IFU) recommended cleaning the tooth before acid etching. None of the IFU directly stated that a handpiece was required to perform the cleaning, but five IFU implied the use of handpiece prophylaxis. None of the IFU recommended surface-altering procedures in caries-free teeth. Direct evidence from two clinical trials showed no difference in complete sealant retention between surfaces cleaned mechanically with pumice or prophylaxis paste and those cleaned with air-water syringe or dry toothbrushing. Indirect evidence from 10 studies found that weighted summary retention by year after sealant placement in studies that used toothbrush prophylaxis was greater than or equivalent to values for studies that used handpiece prophylaxis. Levels of sealant retention after surface cleaning with toothbrush prophylaxis were at least as high as those associated with hand-piece prophylaxis. This finding may translate into lower resource costs for sealant placement.

  2. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates.

    PubMed

    Bryer, Pamela J; Scoggins, Mateo; McClintock, Nancy L

    2010-05-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. A clinical trial to evaluate the retention of a silver cermet-ionomer cement used as a fissure sealant.

    PubMed

    Mills, R W; Ball, I A

    1993-01-01

    A randomized clinical trial was under-taken to compare the retention of a silver cermet-ionomer cement, Ketac Silver, with a conventional, autopolymerizing BIS-GMA resin sealant, Delton, using matched pairs of fissure sites within each subject's mouth. One hundred twenty matched contralateral pairs of fissure sites in first and second permanent molars of 53 school children were sealed with the two materials. The choice of site and material was selected at random. The ages of the children ranged from five to 16 years; first permanent molars were sealed in the five- to 10-year age group, and second permanent molars in the 11- to 16-year age group. Sealants were assessed as present, partly present, or absent at 6, 12, and 24 months. The number of pairs of sites available for reassessment declined from 102 at six months to 59 at 24 months as patients were lost to the study. Retention rates were higher for the Ketac Silver sealants at all three inspection intervals (P < 0.01): 93% compared with 74% at six months, 81% compared with 65% at 12 months, and 83% compared with 58% at 24 months. When analyzed according to age range, the difference between the retention rates was statistically significant in the five- to 10-year-olds but not significant in the 11- to 16-year-olds. The conclusion reached in this study was that cermet cement was better retained than conventional resin sealants in younger children.

  4. The Maine Sealant Manual for School-Based and School-Linked Dental Sealant Programs.

    ERIC Educational Resources Information Center

    Hayward, Kneka, Ed.

    This manual is designed for use by school personnel and dental personnel to aid in the development and maintenance of school-based or school-linked dental sealant programs. The sections include (1) "Introduction"; (2) "Guidelines" (school selection, school contacts, dental providers, target grades, and tooth selection…

  5. Biomimetic, Strong, Tough, and Self-Healing Composites Using Universal Sealant-Loaded, Porous Building Blocks.

    PubMed

    Hwang, Sung Hoon; Miller, Joseph B; Shahsavari, Rouzbeh

    2017-10-25

    Many natural materials, such as nacre and dentin, exhibit multifunctional mechanical properties via structural interplay between compliant and stiff constituents arranged in a particular architecture. Herein, we present, for the first time, the bottom-up synthesis and design of strong, tough, and self-healing composite using simple but universal spherical building blocks. Our composite system is composed of calcium silicate porous nanoparticles with unprecedented monodispersity over particle size, particle shape, and pore size, which facilitate effective loading and unloading with organic sealants, resulting in 258% and 307% increases in the indentation hardness and elastic modulus of the compacted composite. Furthermore, heating the damaged composite triggers the controlled release of the nanoconfined sealant into the surrounding area, enabling moderate recovery in strength and toughness. This work paves the path towards fabricating a novel class of biomimetic composites using low-cost spherical building blocks, potentially impacting bone-tissue engineering, insulation, refractory and constructions materials, and ceramic matrix composites.

  6. Pit and fissure sealants in dental public health – application criteria and general policy in Finland

    PubMed Central

    Kervanto-Seppälä, Sari; Pietilä, Ilpo; Meurman, Jukka H; Kerosuo, Eero

    2009-01-01

    Background Pit and fissure sealants (sealants) are widely used as a non-operative preventive method in public dental health in Finland. Most children under 19 years of age attend the community-organized dental health services free of charge. The aims of this study were to find out to what extent sealants were applied, what the attitudes of dental professionals towards sealant application were, and whether any existing sealant policies could be detected among the health centres or among the respondents in general. The study evaluated changes that had taken place in the policies used during a ten year period (1991–2001). Methods A questionnaire was mailed to each chief dental officer (CDO) of the 265 public dental health centres in Finland, and to a group of general dentists (GDP) applying sealants in these health centres, giving a total of 434 questionnaires with 22 questions. The response rate was 80% (N = 342). Results A majority of the respondents reported to application of sealants on a systematic basis for children with increased caries risk. The criteria for applying sealants and the actual strategies seemed to vary locally between the dentists within the health centres and between the health centres nationwide. The majority of respondents believed sealants had short- and long-term effects. The overall use of sealants decreased towards the end of the ten year period. The health centres (N = 28) choosing criteria to seal over detected or suspected enamel caries lesion had a DMFT value of 1.0 (SD ± 0.49) at age 12 (year 2000) compared to a value of 1.2 (SD ± 0.47) for those health centres (N = 177) applying sealants by alternative criteria (t-test, p < 0.05). Conclusion There seems to be a need for defined guidelines for sealant application criteria and policy both locally and nationwide. Occlusal caries management may be improved by shifting the sealant policy from the traditional approach of prevention to interception, i.e. applying the sealants over

  7. Effect of a surface sealant on the color stability of composite resins after immersion in staining solution.

    PubMed

    Pedroso, Lauana Borges; Barreto, Luma Franciélle Cabreira; Miotti, Leonardo Lamberti; Nicoloso, Gabriel Ferreira; Durand, Leticia Brandão

    2016-01-01

    This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.

  8. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and...

  9. Fibrin sealant use for minimising peri-operative allogeneic blood transfusion

    PubMed Central

    Carless, Paul A; Henry, David A; Anthony, Danielle M

    2014-01-01

    Background Fibrin sealants (also referred to as biological glue or fibrin tissue adhesives) have gained increasing popularity as interventions to improve peri-operative (intra- and post-operative) haemostasis and diminish the need for allogeneic red cell transfusion (blood from an unrelated donor). Objectives To examine the efficacy of fibrin sealants in reducing peri-operative blood loss and allogeneic red blood cell (RBC) transfusion. Search methods We identified studies by searching CENTRAL (The Cochrane Library 2007, Issue 3), MEDLINE (1950 to 2008), EMBASE (1980 to 2008), manufacturer web sites (to March 2008), and bibliographies of relevant published articles. Selection criteria Controlled trials in which adult patients scheduled for elective surgery were randomised to fibrin sealant treatment or to a control group which did not receive fibrin sealant treatment. Trials were eligible if they reported data on the number of patients exposed to allogeneic red cell transfusion, the volume of blood transfused, or blood loss (assessed objectively). Data collection and analysis The primary outcomes measured were the: number of patients exposed to allogeneic red cells, amount of blood transfused, and blood loss. Other outcomes measured were: re-operation due to bleeding, infection, mortality, thrombotic events, and length of hospital stay. Treatment effects were pooled using a random-effects model. Main results Eighteen trials that included a total of 1406 patients reported data on peri-operative exposure to allogeneic RBC transfusion. Fibrin sealant treatment, on average, reduced the rate of exposure to allogeneic RBC transfusion by a relative 37% (relative risk (RR) 0.63, 95% confidence interval (CI) 0.45 to 0.88) and 7% in absolute terms (95% CI 2% to 13%). Fourteen trials, including a total of 853 patients, provided data for post-operative blood loss. In aggregate, fibrin sealant treatment reduced blood loss on average by around 161 ml per patient (95% CI 98.25 to

  10. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...

  11. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...

  12. Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

    PubMed Central

    Cha, Han Gyu; Shin, Ho Seong; Kang, Moon Seok; Nam, Seung Min

    2012-01-01

    Background The most common complication of latissimus dorsi myocutaneous flap in breast reconstruction is seroma formation in the back. Many clinical studies have shown that fibrin sealant reduces seroma formation. We investigated any statistically significant differences in postoperative drainage and seroma formation when utilizing the fibrin sealant on the site of the latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction after skin-sparing partial mastectomy. Methods A total of 46 patients underwent immediate breast reconstruction utilizing a latissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedure without fibrin sealant and the other 23 were administered the fibrin sealant. All flaps were elevated with manual dissection by the same surgeon and were analyzed to evaluate the potential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U test were used for analyzing the drainage volume according to age, weight of the breast specimen, and body mass index. Results Although not statistically significant, the cumulative drainage fluid volume was higher in the control group until postoperative day 2 (530.1 mL compared to 502.3 mL), but the fibrin sealant group showed more drainage beginning on postoperative day 3. The donor site comparisons showed the fibrin sealant group had more drainage beginning on postoperative day 3 and the drain was removed 1 day earlier in the control group. Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Because the benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussed with patients before its use as a part of informed consent. PMID:23094246

  13. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT andmore » BHA were detected in 39–67% of samples, at concentration ranges of« less

  14. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

    PubMed

    Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p <0.05. There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.

  15. Evidence-based clinical practice guideline for the use of pit-and-fissure sealants: A report of the American Dental Association and the American Academy of Pediatric Dentistry.

    PubMed

    Wright, John T; Crall, James J; Fontana, Margherita; Gillette, E Jane; Nový, Brian B; Dhar, Vineet; Donly, Kevin; Hewlett, Edmond R; Quinonez, Rocio B; Chaffin, Jeffrey; Crespin, Matt; Iafolla, Timothy; Siegal, Mark D; Tampi, Malavika P; Graham, Laurel; Estrich, Cameron; Carrasco-Labra, Alonso

    2016-08-01

    This article presents evidence-based clinical recommendations for the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars in children and adolescents. A guideline panel convened by the American Dental Association (ADA) Council on Scientific Affairs and the American Academy of Pediatric Dentistry conducted a systematic review and formulated recommendations to address clinical questions in relation to the efficacy, retention, and potential side effects of sealants to prevent dental caries; their efficacy compared with fluoride varnishes; and a head-to-head comparison of the different types of sealant material used to prevent caries on pits and fissures of occlusal surfaces. This is an update of the ADA 2008 recommendations on the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars. The authors conducted a systematic search in MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and other sources to identify randomized controlled trials reporting on the effect of sealants (available on the US market) when applied to the occlusal surfaces of primary and permanent molars. The authors used the Grading of Recommendations Assessment, Development, and Evaluation approach to assess the quality of the evidence and to move from the evidence to the decisions. The guideline panel formulated 3 main recommendations. They concluded that sealants are effective in preventing and arresting pit-and-fissure occlusal carious lesions of primary and permanent molars in children and adolescents compared with the nonuse of sealants or use of fluoride varnishes. They also concluded that sealants could minimize the progression of noncavitated occlusal carious lesions (also referred to as initial lesions) that receive a sealant. Finally, based on the available limited evidence, the panel was unable to provide specific recommendations on the relative merits of 1 type of sealant material over the others. These

  16. The economics of pit and fissure sealants in preventive dentistry: a review.

    PubMed

    Kitchens, Dinah H

    2005-08-15

    Oral diseases are progressive, cumulative, and become more intricate to treat with advancement. While dental caries is an infectious transmissible disease with children being at the highest risk, primary prevention can reduce this risk. Primary prevention in dentistry is usually considered to be community fluoridated water supplies, professional fluoride treatments, and pit and fissure sealants. While community fluoridated water supplies have been proven to be cost-effective, the cost-effectiveness of pit and fissure sealants has primarily been studied in school-based programs of children from low socio-economic backgrounds. Dental sealant programs are just one way to help increase primary prevention in the oral health disparities of children. The purpose of this paper is to review the literature regarding the cost-effectiveness of pit and fissure sealants as a preventive strategy in preventive dentistry.

  17. Self-Healable and Reprocessable Polysulfide Sealants Prepared from Liquid Polysulfide Oligomer and Epoxy Resin.

    PubMed

    Gao, Wentong; Bie, Mengyao; Liu, Fu; Chang, Pengshan; Quan, Yiwu

    2017-05-10

    Polysulfide sealants have been commercially applied in many industrial fields. In this article, we study the self-healing property of the epoxy resin-cured polysulfide sealants for the first time. The obtained sealants showed a flexible range of ultimate elongation of 157-478% and a tensile strength of 1.02-0.75 MPa corresponding to different polysulfide oligomers. By taking advantage of the dynamic reversible exchange of disulfide bonds, polysulfide sealants exhibited good self-healing ability under a moderate thermal stimulus. A higher molecular weight and a lower degree of cross-linking of polysulfide oligomer were helpful in improving the ultimate elongation and healing efficiency of the polysulfide sealants. After subjecting to a temperature of 75 °C for 60 min, both the tensile strength and ultimate elongation of a fully cut sample, LP55-F, were restored to 91% of the original values, without affecting the sealing property. Furthermore, the sample exhibited excellent reshaping and reprocessing abilities. These outcomes offer a paradigm toward sustainable industrial applications of the polysulfide-based sealants.

  18. Relation Between PAHs and Coal-Tar-Based Pavement Sealant in Urban Environments (Invited)

    NASA Astrophysics Data System (ADS)

    Mahler, B. J.; van Metre, P. C.

    2010-12-01

    Since 2003, coal-tar-based sealant products have come under increased scrutiny as a source of PAHs in urban environments. Sealant (or sealcoat) is the black, shiny substance often applied to asphalt pavement, in particular parking lots and driveways, for esthetic and maintenance purposes. Coal-tar-based sealant, one of the two primary pavement sealant types on the market, typically is 20-35 percent coal-tar pitch, a known carcinogen that is more than 50 percent polycyclic aromatic hydrocarbons (PAHs). The PAH content of the coal-tar-based sealant product is about 1,000 times that of a similar, asphalt-based product, on average. This difference is reflected in regional differences in sealant use and PAH concentrations in pavement dust. In the central and eastern U.S., where the coal-tar-based formulation is prevalent, ΣPAH in mobile particles from sealed pavement have been shown to be about 1,000 times higher than in the western U.S., where the asphalt-based formulation is prevalent (the median ΣPAH concentrations are 2,200 mg/kg in the central and eastern U.S. and 2.1 mg/kg in the western U.S.). Source apportionment modeling indicates that, in the central and eastern U.S., particles from sealed pavement are contributing the majority of the PAHs in recently deposited (post-1990) lake sediment, with implications for ecological health, and that coal-tar-based sealant is the primary cause of upward trends in PAHs in U.S. urban lakes. From the standpoint of human health, research indicates that mobile particles from parking lots with coal-tar-based sealant are tracked indoors, resulting in elevated PAH concentrations in house dust. Coal-tar-based sealcoat being applied to an asphalt parking lot at the University of Texas Pickle Research Center.

  19. Recalcitrant Epithelial Ingrowth After SMILE Treated With a Hydrogel Ocular Sealant.

    PubMed

    Thulasi, Praneetha; Kim, Sang Woo; Shetty, Rohit; Randleman, J Bradley

    2015-12-01

    To report a case of recalcitrant epithelial ingrowth after small incision lenticule extraction (SMILE) treated successfully with a novel hydrogel ocular sealant. Case report and literature review. A 32-year-old man who underwent small incision lenticule extraction (SMILE) complicated by difficult lenticule extraction developed visually significant epithelial ingrowth. He then underwent two flap lifts and epithelial scrapings and flap edge suturing with recurrence of epithelial ingrowth despite these interventions. He subsequently underwent repeat scraping, followed by hydrogel ocular sealant placement (ReSure Sealant; Ocular Therapeutix, Inc., Bedford, MA), which prevented recurrence of epithelial ingrowth and reduced corneal haze. The patient was also found to have undiagnosed diabetes, suggesting that just as in LASIK, diabetes may be a risk factor for epithelial ingrowth after SMILE. Interface epithelial ingrowth is a potential complication after SMILE and diabetes may be a risk factor for this complication. Hydrogel ocular sealant may be effective after SMILE to prevent epithelial ingrowth into the interface. Copyright 2015, SLACK Incorporated.

  20. Estrogenicity of resin-based composites and sealants used in dentistry.

    PubMed Central

    Olea, N; Pulgar, R; Pérez, P; Olea-Serrano, F; Rivas, A; Novillo-Fertrell, A; Pedraza, V; Soto, A M; Sonnenschein, C

    1996-01-01

    We tested some resin-based composites used in dentistry for their estrogenic activity. A sealant based on bisphenol-A diglycidylether methacrylate (bis-GMA) increased cell yields, progesterone receptor expression, and pS2 secretion in human estrogen-target, serum-sensitive MCF7 breast cancer cells. Estrogenicity was due to bisphenol-A and bisphenol-A dimethacrylate, monomers found in the base paste of the dental sealant and identified by mass spectrometry. Samples of saliva from 18 subjects treated with 50 mg of a bis-GMA-based sealant applied on their molars were collected 1 hr before and after treatment. Bisphenol-A (range 90-931 micrograms) was identified only in saliva collected during a 1-hr period after treatment. The use of bis-GMA-based resins in dentistry, and particularly the use of sealants in children, appears to contribute to human exposure to xenoestrogens. Images Figure 1. A Figure 1. B Figure 2. Figure 3. A Figure 3. B Figure 4. A Figure 4. B Figure 5. A Figure 5. B Figure 6. A Figure 6. B Figure 7. A Figure 7. B Figure 8. Figure 9. Figure 10. PMID:8919768

  1. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations

    PubMed Central

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Objective: Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Materials and Methods: Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5–55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal–Wallis and Bonferroni–Dunn test. Results: The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni–Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). Conclusion: The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition. PMID:27095890

  2. A comparison between three different pit and fissure sealants with regard to marginal integrity.

    PubMed

    Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen

    2012-04-01

    THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.

  3. Fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery.

    PubMed

    Cheng, Yao; Ye, Mingxin; Xiong, Xianze; Peng, Su; Wu, Hong Mei; Cheng, Nansheng; Gong, Jianping

    2016-02-15

    Postoperative pancreatic fistula is one of the most frequent and potentially life-threatening complications following pancreatic resections. Fibrin sealants are introduced to reduce postoperative pancreatic fistula by some surgeons. However, the use of fibrin sealants during pancreatic surgery is controversial. To assess the safety, effectiveness, and potential adverse effects of fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery. We searched The Cochrane Library (2015, Issue 7), MEDLINE (1946 to 26 August 2015), EMBASE (1980 to 26 August 2015), Science Citation Index Expanded (1900 to 26 August 2015), and Chinese Biomedical Literature Database (CBM) (1978 to 26 August 2015). We included all randomized controlled trials that compared fibrin sealant group (fibrin glue or fibrin sealant patch) versus control group (no fibrin sealant or placebo) in people undergoing pancreatic surgery. Two review authors independently identified the trials for inclusion, collected the data, and assessed the risk of bias. We performed the meta-analyses using Review Manager 5. We calculated the risk ratio (RR) for dichotomous outcomes (or a Peto odds ratio for very rare outcomes), and the mean difference (MD) for continuous outcomes with 95% confidence intervals (CI). We included nine trials involving 1095 participants who were randomized to the fibrin sealant group (N = 550) and the control group (N = 545) after pancreatic surgery. All of the trials were at high risk of bias. There was no evidence of differences in overall postoperative pancreatic fistula (fibrin sealant 29.6%; control 31.0%; RR 0.93, 95% CI 0.71 to 1.21; P = 0.58; nine studies; low-quality evidence), postoperative mortality (3.1% versus 2.1%; Peto OR 1.29, 95% CI 0.59 to 2.82; P = 0.53; eight studies; very low-quality evidence), overall postoperative morbidity (29.6% versus 28.9%; RR 1.04, 95% CI 0.82 to 1.32; P = 0.77; five studies), reoperation rate (8.7% versus 10

  4. Influence of light-curing mode on the cytotoxicity of resin-based surface sealants.

    PubMed

    Wegehaupt, Florian J; Tauböck, Tobias T; Attin, Thomas; Belibasakis, Georgios N

    2014-05-06

    Surface sealants have been successfully used in the prevention of erosive tooth wear. However, when multiple tooth surfaces should be sealed, the light-curing procedure is very time-consuming. Therefore, the aim of this study was to investigate whether reduced light-curing time (while maintaining similar energy density) has an influence on resin-based surface sealant cytotoxicity. Bovine dentine discs were treated as follows: group 1: untreated, groups 2-5: Seal&Protect and groups 6-9: experimental sealer. Groups 2 and 6 were light-cured (VALO LED light-curing device) for 40 s (1000 mW/cm2), groups 3 and 7 for 10 s (1000 mW/cm2), groups 4 and 8 for 7 s (1400 mW/cm2) and groups 5 and 9 for 3 s (3200 mW/cm2). Later, materials were extracted in culture medium for 24 h, and released lactate dehydrogenase (LDH) activity as a measure of cytotoxicity was determined photometrically after cells (dental pulp cells and gingival fibroblasts) were exposed to the extracts for 24 h. Three independent experiments, for both sample preparation and cytotoxicity testing, were performed. Overall, lowest cytotoxicity was observed for the unsealed control group. No significant influence of light-curing settings on the cytotoxicity was observed (p = 0.537 and 0.838 for pulp cells and gingival fibroblasts, respectively). No significant difference in the cytotoxicity of the two sealants was observed after light-curing with same light-curing settings (group 2 vs. 6, 3 vs. 7, 4 vs. 8 and 5 vs. 9: p > 0.05, respectively). Shortening the light-curing time, while maintaining constant energy density, resulted in no higher cytotoxicity of the investigated sealants.

  5. Impact of adhesive and photoactivation method on sealant integrity and polymer network formation.

    PubMed

    Borges, Boniek Castillo Dutra; Pereira, Fabrício Lopes da Rocha; Alonso, Roberta Caroline Bruschi; Braz, Rodivan; Montes, Marcos Antônio Japiassú Resende; Pinheiro, Isauremi Vieira de Assunção; Santos, Alex José Souza dos

    2012-01-01

    We evaluated the influence of photoactivation method and hydrophobic resin (HR) application on the marginal and internal adaptation, hardness (KHN), and crosslink density (CLD) of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10) and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL), no adhesive system + photoactivation of the sealant using the soft-start method (SS), HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h. The CLD was indirectly assessed by repeating the KHN measurement after 24 h of immersion in 100% ethanol. There was no difference among the samples with regard to marginal or internal adaptation. The KHN and CLD were similar for samples cured using either photoactivation method. Use of a hydrophobic resin prior to placement of fissure sealants and curing the sealant using the soft-start method may not provide any positive influence on integrity or crosslink density.

  6. Effectiveness of a new gelatin sealant system for dural closure.

    PubMed

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P < 0·001) or the PEG-based hydrogel sealant (46·3 ± 20·9 mmHg, P  =  0·007). Bonding strength was higher for the gelatin glue than fibrin glue (P < 0·001) or PEG-based hydrogel sealant (P  =  0·001). The maximum intracranial pressure in the in vivo model was higher for the gelatin glue group (59·0 ± 2·2 mmHg) than the control group (13·8 ± 4·0 mmHg, P < 0·001). Tissue adhesion was lower for the gelatin glue group than the control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  7. PAH volatilization following application of coal-tar-based pavement sealant

    USGS Publications Warehouse

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, have recently been identified as a source of volatile PAHs to the atmosphere. We tracked the volatilization of PAHs for 1 year after application of a coal-tar-based pavement sealant by measuring gas-phase PAH concentrations above the pavement surface and solid-phase PAH concentrations in sealant scraped from the surface. Gas-phase concentrations at two heights (0.03 and 1.28 m) and wind speed were used to estimate volatilization flux. The sum of the concentrations of eight frequently detected PAHs (ΣPAH8) in the 0.03-m sample 1.6 h after application (297,000 ng m-3) was about 5000 times greater than that previously reported for the same height above unsealed parking lots (66 ng m-3). Flux at 1.6 h after application was estimated at 45,000 μg m-2 h-1 and decreased rapidly during the 45 days after application to 160 μg m-2 h-1. Loss of PAHs from the adhered sealant also was rapid, with about a 50% decrease in solid-phase ΣPAH8 concentration over the 45 days after application. There was general agreement, given the uncertainties, in the estimated mass of ΣPAH8 lost to the atmosphere on the basis of air sampling (2–3 g m-2) and adhered sealant sampling (6 g m-2) during the first 16 days after application, translating to a loss to the atmosphere of one-quarter to one-half of the PAHs in the sealcoat product. Combining the estimated mass of ΣPAH8 released to the atmosphere with a national-use estimate of coal-tar-based sealant suggests that PAH emissions from new coal-tar-based sealcoat applications each year (~1000 Mg) are larger than annual vehicle emissions of PAHs for the United States.

  8. Systematic review and meta-analysis of fibrin sealants for patients undergoing pancreatic resection

    PubMed Central

    Orci, Lorenzo A; Oldani, Graziano; Berney, Thierry; Andres, Axel; Mentha, Gilles; Morel, Philippe; Toso, Christian

    2014-01-01

    Introduction Post-operative pancreatic fistula (POPF) is a common complication after partial pancreatic resection, and is associated with increased rates of sepsis, mortality and costs. The role of fibrin sealants in decreasing the risk of POPF remains debatable. The aim of this study was to evaluate the literature regarding the effectiveness of fibrin sealants in pancreatic surgery. Methods A comprehensive database search was conducted. Only randomized controlled trials comparing fibrin sealants with standard care were included. A meta-analysis regarding POPF, intra-abdominal collections, post-operative haemorrhage, pancreatitis and wound infections was performed according to the recommendations of the Cochrane collaboration. Results Seven studies were included, accounting for 897 patients. Compared with controls, patients receiving fibrin sealants had a pooled odds ratio (OR) of developing a POPF of 0.83 [95% confidence interval (CI): 0.6–1.14], P = 0.245. There was a trend towards a reduction in post-operative haemorrhage (OR = 0.43 (95%CI: 0.18–1.0), P = 0.05) and intra-abdominal collections (OR = 0.52 (95%CI: 0.25–1.06), P = 0.073) in those patients receiving fibrin sealants. No difference was observed in terms of mortality, wound infections, re-interventions or hospital stay. Conclusion On the basis of these results, fibrin sealants cannot be recommended for routine clinical use in the setting of pancreatic resection. PMID:23461684

  9. Clinical performance of a glass ionomer sealant protected with two different resin-based agents over a 2-year follow-up period.

    PubMed

    Ulusoy, A T; Tunc, E S; Bayrak, Ş

    2017-03-01

    To evaluate the effects of two different resin coating materials on the clinical performance of a conventional glass ionomer sealant. Permanent first mandibular molars of 60 children aged 6-9 years were sealed with Fuji VII. In each child, G-Coat Plus coating agent was applied to molars on one side and Heliobond coating agent to molars on the opposite side of the mouth. Clinical evaluations were carried out at 1, 6, 12, 18 and 24 months after sealant and coating application. At 1, 6, 12, 18 and 24 months after sealant and coating application, total sealant retention rates were 88%, 40%, 19%, 15% and 9% for molars coated with G-Coat Plus, and 93%, 47%, 17%, 15% and 7% for those coated with Heliobond. The differences between the two coating agents were not statistically significant (p>0.05). No incidence of caries was observed in either group during the two-year evaluation period. Wilcoxon signed rank test was used to compare differences in retention rates and caries incidence by coating agent. Although retention rates of Fuji VII were relatively low and similar for both resin coating agents tested, dental caries were not observed in either group during the 24-month study period. In children with a high risk of caries and partially erupted molars, the use of a glass ionomer sealant with a resin-based coating agent should be encouraged.

  10. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    PubMed

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  11. Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain.

    PubMed

    Healy, Ciaran; Greig, Aina V H; Murphy, Adrian D; Powell, Christopher; Pinder, Richard J; Saour, Samer; Abela, Christopher; Knight, William; Geh, Jenny L C

    2013-07-01

    Pain at split skin graft donor sites is common. Fibrin sealant has been demonstrated to reduce time to hemostasis at wound sites, and patients receiving this treatment were incidentally noted to report less pain. This study aimed to evaluate pain and incapacity in split skin graft donor sites treated with and without fibrin sealant. Fifty patients requiring thigh donor-site split skin grafts were prospectively randomized to receive either a self-adhesive fabric dressing alone or fibrin sealant plus the self-adhesive fabric dressing as primary donor-site dressings. External secondary dressings were the same. Patients were blinded with regard to treatment group. Using visual analogue scales (scored 0 to 5), patients rated their donor-site pain and incapacity for 14 days postoperatively. Secondary endpoints were length of hospital stay and duration of requirement for dressings. Forty patients were included in the study analysis and completed self-reported pain and incapacity scores. Twenty received the fibrin sealant plus self-adhesive fabric dressing and 20 received the fabric dressing only (controls). Patients using the fibrin sealant plus the dressing reported significantly less pain (mean score, 0.42 versus 1.60, p < 0.001) and significantly less incapacity (mean score, 0.48 versus 1.71, p < 0.001). Patients allocated to the fibrin sealant group recorded shorter lengths of stay and faster time to discontinuation of dressing, though statistical significance was not achieved. Patients whose split skin graft donor sites were dressed with fibrin sealant plus self-adhesive fabric dressing experienced significantly less pain and incapacity than patients with self-adhesive fabric dressings alone, allowing a more rapid return to normal activity. Therapeutic, II.

  12. Estimating emissions from adhesives and sealants uses and manufacturing for environmental risk assessments.

    PubMed

    Tolls, Johannes; Gómez, Divina; Guhl, Walter; Funk, Torsten; Seger, Erich; Wind, Thorsten

    2016-01-01

    Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) requires that environmental exposure assessments be performed for all uses of dangerous substances that are marketed in the European Union in quantities above 10 tons per year. The quantification of emissions to the environment is a key step in this process. This publication describes the derivation of release factors and gives guidance for estimating use rates for quantifying the emissions from the manufacturing and application of adhesives and sealants. Release factors available for coatings and paints are read across to adhesives or sealants based on similarities between these 2 product groups with regard to chemical composition and to processing during manufacturing and application. The granular emission scenarios in these documents are mapped to the broad emission scenarios for adhesives or sealants. According to the mapping, the worst-case release factors for coatings or paints are identified and assigned to the adhesives or sealants scenarios. The resulting 10 specific environmental release categories (SPERCs) for adhesives and sealants are defined by differentiating between solvent and nonsolvent ingredients and between water-borne and solvent-borne or solvent-free products. These cover the vast majority of the production processes and uses and are more realistic than the 5 relevant emission estimation defaults provided in the REACH guidance. They are accompanied with adhesive or sealant consumption rates in the EU and with guidance for estimating conservative substance use rates at a generic level. The approach of combining conservative SPERC release factors with conservative estimates of substance rates is likely to yield emission estimates that tend to overpredict actual releases. Because this qualifies the approach for use in lower-tier environmental exposure assessment, the Association of the European Adhesive & Sealant Industry

  13. Retention of fissure sealants in young permanent molars affected by dental fluorosis: a 12-month clinical study.

    PubMed

    Hasanuddin, S; Reddy, E R; Manjula, M; Srilaxmi, N; Rani, S T; Rajesh, A

    2014-10-01

    To evaluate and compare retention and caries occurance following placement of Clinpro and FUJI VII fissure sealants, by two different techniques simultaneously in unsealed, contralateral young permanent molars of 7- to 10-year-old children affected by mild to moderate dental fluorosis at various recall intervals of 1 week, 1, 3, 6 and 12 months. 80 schoolchildren with mild to moderate dental fluorosis were assigned to Group A and Group B with 40 children in each group. In Group A Clinpro fissure sealant and in Group B Fuji VII fissure sealant was used. In both the groups fissure sealants were applied by conventional fissure sealant technique (CST) on one side and enameloplasty sealant technique (EST) on the other side of the same arch. The applied fissure sealants were evaluated clinically for retention and caries incidence. Clinpro fissure sealant showed a retention rate of 95% when compared with Fuji VII (57.5%) at the end of 12 months, which was statistically significant. Regarding techniques, EST showed better results than CST in both the groups. Comparison of groups with respect to retention and techniques at different time periods was performed using Mann-Whitney U test (p < 0.05). Comparison of different time periods with respect to retention and technique in all the groups was performed using Wilcoxon matched pairs test by ranks (p < 0.05). Clinpro fissure sealant showed better retention at all treatment intervals, when compared with Fuji VII. Further follow-up is required to study the efficacy of the fissure sealant placement techniques.

  14. A method to determine shear adhesive strength of fibrin sealants.

    PubMed

    Sierra, D H; Feldman, D S; Saltz, R; Huang, S

    1992-01-01

    The adhesive strength of fibrin sealants has not been rigorously evaluated to date. The adhesive strength of six different concentrations of cryoprecipitated fibrinogen as well as the commercially available fibrin tissue adhesive Tissucol was tested under controlled conditions utilizing split-thickness skin grafts as the test adherand. This test configuration permitted the modeling of bonding strength for attachment of skin grafts as well as incorporate established engineering test standards for adhesives. An increase in fibrin concentration corresponded with an increase in shear adhesive strength. No significant increases in adhesive strength were attained after 5 min of bonding for all tested concentrations, except for the commercial adhesive, which attained the adhesive strength of an equivalent concentration of cryoprecipitated adhesive after 90 min. The adhesive strength, however, was an order of magnitude less than reported values of the tensile strength of fibrin material for similar concentrations. Therefore, it is important that the surgeon use a sufficiently high fibrinogen concentration for the specific clinical indication. The method of fibrin sealant preparation and/or the compounding adjuncts appear to have an effect on the development of adhesive strength.

  15. Investigating crack sealant performance and causes of bumps in new hot mix asphalt overlays over crack sealants.

    DOT National Transportation Integrated Search

    2011-07-01

    This final report is intended to provide information regarding the performance of crack sealants supplied and installed by : three manufacturers for experimental use in a three-year evaluation of in-service pavements on three Colorado highways. : In ...

  16. Effect of type and content of tackifier on adhesion of natural rubber and reclaimed natural rubber based sealant

    NASA Astrophysics Data System (ADS)

    Raethong, P.; Boonkerd, K.

    2017-07-01

    Adhesion property of natural rubber (NR) and reclaimed natural rubber (RNR) based sealant with concrete was studied here. The effect of tackifier type and loading on the tensile properties of the rubber based sealant sandwished between two flat cements was evaluated. There are three different tackifiers including Coumarone-indene resin (CI), petro resin (PE) and gum rosin (GR). The result initially showed that at the 20 phr of tackifier both NR and RNR sealant mixed with CI consumed the highest force to separate the rubber based sealant from the concrete. This might be due to the highest compatiblility between CI and rubber. Regardless of the tackifier type, all NR based sealants showed the cohesive failure while all RNR based sealants only showed the adhesive failure. Moreover, the NR based sealant seemed to be stronger than the RNR based one. When considering the effect of CI loading on the adhesion, it was shown that for both NR and RNR based sealents, the highest stress was observed when the rubber based sealant loaded with the 20 phr of CI.

  17. First Permanent Molar Restoration Differences between Those with or without Dental Sealants.

    ERIC Educational Resources Information Center

    Kuthy, Raymond A.; And Others

    1990-01-01

    The study examined differences in the number of restorations in permanent, posterior teeth for those children receiving dental sealants with cost sharing when compared to children who do not receive sealants. Results indicated a 51 percent reduction in restoration rates for each quadrant sealed. Findings have implications for cost savings and…

  18. Retention of Moisture-tolerant and Conventional Resin-based Sealant in Six- to Nine-year-old Children.

    PubMed

    Khatri, Sachin G; Samuel, Srinivasan Raj; Acharya, Shashidhar; Patil, Snehal; Madan, Kavita

    2015-01-01

    The purpose of this study was to evaluate and compare the retention rates and development of caries in permanent molars in children sealed with moisture-tolerant, resin-based (Embrace WetBond), and conventional resin-based (Helioseal) sealant over a period of one year. This was a double blind, split-mouth, randomized controlled trial among six- to nine-year-olds. Sixty-eight permanent mandibular first molars in 34 children were randomly assigned to be sealed with Embrace WetBond or Helioseal sealant. The final sample was 32 children with 64 teeth. At 12 months, 23 of 32 (72 percent) sealants were completely retained in Embrace WetBond, whereas only 16 of 32 (50 percent) were retained in the Helioseal group. There was a statistically significant difference in retention rates of Embrace WetBond and Helioseal sealants at 12 months (P<.05). At 12 months follow-up, only two teeth developed caries in Embrace WetBond; in the Helioseal group, five teeth developed caries (two initial and three enamel caries). Embrace WetBond was superior to Helioseal sealant, as Embrace exhibited higher retention and lower caries scores. Embrace WetBond can be preferred over conventional resin-based sealants for community and outreach sealant programs where use of rubber dam for moisture control is difficult to practice.

  19. Adherence and efficacy of an external teat sealant to prevent new intramammary infections in the dry period.

    PubMed

    Lim, G H; Leslie, K E; Kelton, D F; Duffield, T F; Timms, L L; Dingwell, R T

    2007-03-01

    The efficacy and adherence of an external teat sealant applied at drying off was evaluated in 2 studies between 1997 and 1999. At drying off, 2 quarters were randomized to receive intramammary dry-cow antibiotic therapy, and the remaining 2 quarters were treated with either a single or double application of external teat sealant. Approximately 3 d before calving, all teats that had been dipped at drying off were redipped in a single coating of teat sealant. Adherence of the teat sealant was scored for the first 2 wk after drying off, and physical traits of the teat skin and teat ends were recorded. Quarter milk samples were collected 1 wk before drying off, at drying off, 0 to 7 d, and 14 to 21 d postcalving. Somatic cell counts were determined from quarter samples taken at d 7 and 14 to 21 d after calving. Data were analyzed from 172 dry periods of 162 cows. The mean time of sealant adherence following drying off application was 3 +/- 0.13 d. Double sealant application significantly increased the duration of adherence by 0.67 d. Teats that had teat sealant applied twice at drying off and that had up to 3 d of adherence had the lowest linear score (LS) at 14 to 21 d (1.89 +/- 0.31) of all quarters. The LS of quarters that received antibiotic therapy only was 2.27 +/- 0.19. The majority of intramammary infections identified at drying off were caused by the minor pathogens, coagulase-negative staphylococci and Corynebacterium bovis (51 and 23%, respectively). The results from this study indicate that duration of sealant adherence to the teat-end should be considered when evaluating the impact of teat sealant treatment at drying off on the level of infection after calving. Double sealant application, cooler seasons, and longer teat lengths were associated with a significant increase in the duration of sealant adherence to the teat-end.

  20. The retention of pit and fissure sealants placed in primary school children by Dental Health Services, Victoria.

    PubMed

    Messer, L B; Calache, H; Morgan, M V

    1997-08-01

    The benefit of a public sector sealant programme for children in Australia is yet to be established. This study evaluated sealants placed by therapists of the School Dental Service in Victoria, between 1989 and 1994, on permanent teeth of children in 15 primary schools in Melbourne. Seven hundred and seventy four children aged 6-12 years were examined in school dental clinics by six calibrated examiners. A total of 5363 sealants placed on 2875 permanent teeth (including 2616 first molars, 91 per cent of sample) up to four and a half years previously was examined. Values for complete and partial sealant retention were highest for premolars (86 per cent, 9 per cent respectively, total 95 per cent); similar for occlusal surfaces of maxillary and mandibular first molars (63 per cent, 30 per cent; 62 per cent, 32 per cent respectively) and buccal pits of mandibular molars (66 per cent); and low for pits/fissures of Carabelli's cusps of maxillary molars (44 per cent). Cross-sectional examination up to 24 months for both maxillary and mandibular first molars indicated average values of 67 per cent complete retention, 27 per cent partial retention, 6 per cent missing; thereafter complete retention decreased and partial retention increased. Sealant failures in the six months post-placement were attributed to technique failure. Regardless of sealant retention, caries experience was low under partially retained or missing sealants (4.5 per cent) and completely retained sealants (0.4 per cent). It is concluded that the SDS sealant programme is a sound preventive dental public health approach.

  1. Evidence-practice gap for dental sealant application: results from a dental practice-based research network in Japan.

    PubMed

    Yokoyama, Yoko; Kakudate, Naoki; Sumida, Futoshi; Matsumoto, Yuki; Gilbert, Gregg H; Gordan, Valeria V

    2016-12-01

    The study aims were: (i) to examine dentist practice patterns regarding treatment recommendations for dental sealants; and (ii) to identify characteristics associated with this recommendation. The study was performed using a cross-sectional questionnaire survey (Clinicaltrials.gov registration number NCT01680848). Participants were Japanese dentists (n = 282) recruited from the Dental Practice-based Research Network Japan. Three clinical photographs of the occlusal surface of a mandibular first molar were presented, portraying increasing depths of cavitation in a 12-year-old patient with high caries risk. Sealants would be an appropriate treatment in all three scenarios. We asked about the treatment decision for each case. We then performed multiple logistic regression analyses to evaluate associations between the decision to recommend sealants, and dentist, patient and practice characteristics. Responses were obtained from 189 dentists (response rate = 67%). In the hypothetical scenarios, dentists' recommendations for sealants for the 12-year-old patient varied from 16% to 26% across the three hypothetical clinical scenarios. Multiple logistic regression analysis indicated that dentist agreement with the efficacy of assessment for caries risk showed a significant association with the percentages of patients receiving sealants. Dentist practice patterns for sealant treatment recommendation show changes that are dependent on caries severity. The dentists' recommendations for sealants for the 12-year-old patient were low for all three selected scenarios, based on indications for sealants in the American Dental Association guidelines. Recommending a sealant showed a significant relationship with the dentist having a higher agreement with efficacy of caries risk assessment. © 2016 FDI World Dental Federation.

  2. Microtensile Bond Strength of Embrace Wetbond Hydrophilic Sealant in Different Moisture Contamination: An In-Vitro Study.

    PubMed

    Panigrahi, Antarmayee; Srilatha, K T; Panigrahi, Rajat G; Mohanty, Susant; Bhuyan, Sanat K; Bardhan, Debojyoti

    2015-07-01

    Contamination of etched enamel with saliva has been shown to result in sealant failure. Recently, a hydrophilic sealant has been introduced. In absence of documented literature, this in vitro study was undertaken to ascertain the efficacy of Embrace Wet Bond without reduction of microtensile bond strength in the different moisture contamination. A 5mm block of sealant were built over prepared occlusal surface of 40 non-carious therapeutically extracted third molars which were sectioned into 1mm thick stick and tested using Zwick micro tensile tester. Obtained data were subjected to descriptive analysis, one-way ANOVA and Scheffe's post-hoc tests. Mean microtensile bond strength of Embrace sealant was not significantly lowered in different moisture contamination groups except Group 3 (air drying), which showed very highly significant (p<0.001) decrease in μTBS as compared to Group 1 (non-contaminated). Mean μTBS of Embrace sealant remains largely unchanged even in presence of moisture. Owing to its hydrophilic property, this sealant can be a great help in cases where maintaining isolation is difficult.

  3. Hydrogel sealant versus sutures to prevent fluid egress after cataract surgery.

    PubMed

    Masket, Samuel; Hovanesian, John A; Levenson, Jeffrey; Tyson, Farrell; Flynn, William; Endl, Michael; Majmudar, Parag A; Modi, Satish; Chu, Ralph; Raizman, Michael B; Lane, Stephen S; Kim, Terry

    2014-12-01

    To evaluate the effectiveness of a hydrogel sealant versus a suture in preventing fluid egress after wound leakage in cataract surgery. Twenty-four ophthalmic clinical practices in the United States. Prospective randomized parallel-arm controlled multicenter subject-masked study. Healthy patients having uneventful clear corneal incision (CCI) cataract surgery were eligible for the study. Spontaneous and provoked fluid egress from wounds was evaluated at the time of surgery using a calibrated force gauge. Eyes with leakage were randomized to receive a hydrogel sealant (Resure) or a nylon suture at the main incision site. Incision leakage was reevaluated 1, 3, 7, and 28 days postoperatively. Of 500 eyes, 488 had leakage at the time of cataract surgery. The leak was spontaneous in 244 cases (48.8%), and 488 (97.6%) of all incisions leaked with 1.0 ounce or less of applied force. After randomization, 12 (4.1%) of 295 eyes in the sealant group and 60 (34.1%) of 176 eyes in the suture group had wound leakage with provocation (P<.0001). The overall incidence of adverse ocular events was statistically significantly lower in the sealant group than in the suture group (P<.05). In this study, 97.6% of CCIs leaked after cataract surgery. The hydrogel sealant was safe and effective and better than a suture for the intraoperative management of CCIs with leakage as seen on Seidel testing and for the prevention of postoperative fluid egress. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Dextran/Albumin hydrogel sealant for Dacron(R) vascular prosthesis.

    PubMed

    Lisman, Anna; Butruk, Beata; Wasiak, Iga; Ciach, Tomasz

    2014-05-01

    In this paper, the authors describe a novel type of hydrogel coating prepared from the copolymer of human serum albumin and oxidized dextran. The material was designed as a hydrogel sealant for polyester (Dacron®)-based vascular grafts. Dextran was chosen as a coating material due to its anti-thrombogenic properties. Prepared hydrogels were compared with similar, already known biomaterial made from gelatine with the same cross-linking agent. Obtained hydrogels, prepared from various ratios of oxidized dextran/albumin or oxidized dextran/gelatine, showed different cross-linking densities, which caused differences in swelling, degradation rate and mechanical properties. Permeability tests confirmed the complete tightness of the hydrogel-modified prosthesis. Results showed that application of the hydrogel coating provided leakage-free prosthesis and eliminated the need of pre-clotting.

  5. Effect of intracameral injection of fibrin tissue sealant on the rabbit anterior segment

    PubMed Central

    Chew, Annabel C.Y.; Tan, Donald T.H.; Poh, Rebekah; HM, Htoon; Beuerman, Roger W.

    2010-01-01

    Purpose To investigate the effect of intracameral injection of fibrin tissue sealant on the anterior segment structures in a rabbit model. Methods One eye of 10 rabbits received an intracameral injection of fibrin tissue sealant with a thrombin concentration of 500 IU (TISSEEL), and the fellow eye received an intracameral injection of balanced salt solution as a control. The rabbits were followed up with serial slit-lamp examinations, photography, high resolution anterior segment optical coherence tomography scans with pachymetry measurement, and intraocular pressure (IOP) monitoring until complete dissolution of the fibrin sealant. Corneal endothelial cell viability was evaluated using live/dead cell assays. Apoptosis of the cornea and trabecular meshwork were evaluated using TUNEL assays. Ultra-structural examinations of the cornea and trabecular meshwork were performed using electron microscopy. Histology of the trabecular meshwork and iris were analyzed using light microscopy. Results The quantity of the intracameral fibrin sealant was shown to be significantly correlated with increased IOP and pachymetry post-operatively. Complete dissolution of the fibrin sealant occurred between 15 and 30 days. Live/dead cell assays showed no decrease in viability of the corneal endothelium, and TUNEL assays showed no increase in apoptosis of the corneal epithelium, stroma, endothelium, or trabecular meshwork in the eyes with the fibrin sealant. Light and electron microscopy of the anterior segment structures were unremarkable. Conclusion The intracameral use of fibrin glue was associated with a transient increase in IOP and pachymetry. However, there was no evidence of toxicity or structural damage to the corneal endothelium, trabecular meshwork, or iris. PMID:20596250

  6. Rocket Motor Joint Construction Including Thermal Barrier

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor); Dunlap, Patrick H., Jr. (Inventor)

    2002-01-01

    A thermal barrier for extremely high temperature applications consists of a carbon fiber core and one or more layers of braided carbon fibers surrounding the core. The thermal barrier is preferably a large diameter ring, having a relatively small cross-section. The thermal barrier is particularly suited for use as part of a joint structure in solid rocket motor casings to protect low temperature elements such as the primary and secondary elastomeric O-ring seals therein from high temperature gases of the rocket motor. The thermal barrier exhibits adequate porosity to allow pressure to reach the radially outward disposed O-ring seals allowing them to seat and perform the primary sealing function. The thermal barrier is disposed in a cavity or groove in the casing joint, between the hot propulsion gases interior of the rocket motor and primary and secondary O-ring seals. The characteristics of the thermal barrier may be enhanced in different applications by the inclusion of certain compounds in the casing joint, by the inclusion of RTV sealant or similar materials at the site of the thermal barrier, and/or by the incorporation of a metal core or plurality of metal braids within the carbon braid in the thermal barrier structure.

  7. Polyethylene glycol hydrogel polymer sealant for vitrectomy surgery: an in vitro study of sutureless vitrectomy incision closure.

    PubMed

    Hariprasad, Seenu M; Singh, Ajay

    2011-03-01

    To test a novel hydrogel sealant to secure sutureless sclerotomies under variable intraocular pressure conditions. In cadaver eyes, 23- and 20-gauge (G) sclerotomies were constructed. Sixteen 23-G beveled sclerotomies were constructed in 4 eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were left bare. All sclerotomies were monitored for leaks while the intraocular pressure was elevated. The pressure on incision leakage was recorded as the leak pressure (maximum tested = 140 mm Hg). Additionally, sixteen 20-G sclerotomies were constructed in 4 other eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were sutured. These incisions were similarly pressure tested. Among the 23-G incisions, hydrogel sealant application to the incisions significantly increased the leak pressure relative to bare incisions: mean (SE), 131.8 (8.2) vs 39.5 (5.2) mm Hg, respectively (P < .001). Only 1 of the 8 sealant-treated 23-G incisions leaked below 140 mm Hg, compared with all of the 8 bare incisions. Among the 20-G incisions, there was no difference in leak pressure among sealant-treated and sutured incisions: mean (SE), 140.0 (0.0) vs 136.3 (3.8) mm Hg, respectively (P = .35). None of the 8 sealant-treated 20-G incisions leaked below 140 mm Hg, compared with 1 of the 8 sutured incisions. Hydrogel sealant significantly increased the leak pressure among 23-G incisions relative to 23-G bare incisions and was equivalent to suturing among 20-G incisions. Hydrogel sealants effectively close vitrectomy incisions and may decrease the incidence of postoperative endophthalmitis and hypotony.

  8. Fibrin sealants: surgical hemostat, sealant and adhesive.

    PubMed

    Mandell, Samuel P; Gibran, Nicole S

    2014-06-01

    Fibrin sealants (FS) have been approved for use in the United States since 1998. Since approval, they have been used in a wide variety of clinical settings and new products continue to be introduced. This review covers the literature supporting the USA FDA-approved indications for FS products produced by Baxter Corp. Literature review of PubMed, the Cochrane Library, FDA approval documents and product websites yielded information contained in this article. Mechanism of action, efficacy and safety of these products are covered. FS are generally safe, popular and are used for a wide variety of off-label indications. Their use appears to be expanding rapidly. For many uses, including approved ones, large well-controlled trials are still needed. Additionally, cost-effectiveness data for these products would be a great benefit in guiding their future use.

  9. Safety and usability of hemostats, sealants, and adhesives.

    PubMed

    Burks, Sandra; Spotnitz, William

    2014-08-01

    Hemostats, sealants, and adhesives are an integral part of surgical patient care. Nurses who have knowledge about these agents can better help ensure safe, efficient surgical patient care. As a caregiver and patient advocate, the perioperative nurse must understand the most current information about these agents and be prepared to facilitate the transfer of this knowledge to all caregivers. Information about these agents, including the contraindications, warnings, and precautions associated with their use as well as their preparation and application, is provided here. Algorithms designed to clarify the best options for using hemostats, sealants, and adhesives are included as well. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  10. [Eosinophilic pleural effusion possibly induced by fibrin sealant].

    PubMed

    Kambayashi, Takatoyo; Suzuki, Takashi

    2012-02-01

    A 74-year-old man underwent right upper lobectomy for the lung cancer and bullectomy of right lower lobe. Fibrin sealant was used for sealing the excision line. The increase of the pleural effusion with increasing C-reactive protein( CRP) and eosinophilia was noted at the 17th day after the operation. The pleural effusion was transparent and yellowish colored suggesting transudatory liquid. The eosinophil in the pleural effusion was as high as 14%. The drainage of the pleural effusion was performed for 2 days resulting in disappearing the abnormal accumulation without any additional treatment. The cause of pleural effusion was supposed to be fibrin sealant by a positive result of the drug lymphocyte stimulation test.

  11. Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents.

    PubMed

    Ahovuo-Saloranta, A; Hiiri, A; Nordblad, A; Worthington, H; Mäkelä, M

    2004-01-01

    Fissure sealants used on occlusal tooth surfaces were introduced in the 1960s for protecting pits and fissures from dental caries. Although sealants have demonstrated to be effective in preventing caries, their efficacy may be related to the background caries prevalence in the population. The primary objective of this review was to evaluate the caries prevention of resin based pit and fissure sealants and glass ionomer cements or sealants in children and adolescents. We searched the Cochrane Oral Health Group's Trials Register (last update December 2002), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 4, 2002), MEDLINE via OVID (1966 to December 2002), EMBASE (1974 to February 2002), SCISEARCH, SIGLE, CAplus, INSPEC, JICST-EPLUS, NTIS, PASCAL (February 2002) and DARE, NHS EED, HTA (March 2002). Reference lists from included articles and review articles were searched for additional relevant articles. All relevant studies in most languages were considered and translated. Randomised or quasi-randomised controlled trials of at least 12 months in duration in which sealants were used for preventing caries in children and adolescents under 20 years of age were included. The primary outcome was the increment in the numbers of carious occlusal surfaces of premolars and molars. In the first phase, two reviewers independently examined whether a given study was likely to be relevant on the basis of the title, key words and abstract. In the second phase, four of the reviewers independently classified studies to be included in final analyses. Study authors were contacted for additional information. In the split-mouth studies relative risk ratios were calculated for the paired differences of tooth surfaces being carious or not. In studies comparing resin based sealant with no treatment, fixed effect meta-analyses were used to combine the estimates of relative risk ratios. In one parallel group study, the mean DFS data as continuous data

  12. Analysis of the hemostatic potential of modern topical sealants on arterial and venous anastomoses: an experimental porcine study.

    PubMed

    Fonouni, Hamidreza; Kashfi, Arash; Majlesara, Ali; Stahlheber, Oliver; Konstantinidis, Lukas; Kraus, Thomas W; Mehrabi, Arianeb; Oweira, Hani

    2017-09-01

    One of the widely accepted adjunctive agents in the variety of surgical modalities are sealants. Our study aim was to compare four commonly used modern sealants in a standardized experimental setting to assess their feasibility, and hemostatic efficacy in vascular anastomosis. Forty landrace pigs (weight: 24.7 ± 3.8 kg) were randomized into the control (n = 8) and four sealant groups; TachoSil® (n = 8), Tissucol Duo® (n = 8), Coseal® (n = 8), and FloSeal® (n = 8). After doing a portal vein end-to-end anastomosis as well as stitches of aortic incision, the sealants were applied on anastomotic site. The control group was left intact. In portal vein anastomosis, the sealants led to a complete hemostasis significantly better than control group. The mean of blood loss was also significantly reduced. In successful subgroups, there was a difference in the mean-time to reach complete hemostasis ranging from 15 s in Coseal® to 76 s in FloSeal® group (p  < 0.05). In aortotomy experiments, except Tissucol Due®, which had insufficient hemostasis, other sealants led to a complete hemostasis. The mean blood loss was significantly reduced in sealants groups as well. The four sealants are effective in reducing the suture-hole bleeding in portal vein anastomosis. However, the hemostatic potential is heterogeneous among sealants. This means that "one-size-fits-all" approach is not appropriate for application of sealants in diversity of vascular surgery and it should be based on the type and the severity of injury and the structure of tissue. Comparison of hemostasis efficacy of four modern sealants (TachoSil®, Tissucol Duo®, Coseal®, and FloSeal®) in vascular anastomosis in porcine model. The figures below show the total blood loss (g) in the control and sealant groups after aortotomy (left) and portal vein anastomosis (right). The mean of blood loss decreased significantly by the usage of sealants in both experiment groups as compared

  13. Minimally Invasive Pterygium Surgery: Sutureless Excision with Amniotic Membrane and Hydrogel Sealant.

    PubMed

    Bondalapati, Sailaja; Ambati, Balamurali

    2016-01-01

    To describe a novel technique for sutureless pterygium surgery using ReSure(®) tissue sealant. In this retrospective observational case series, we describe a modified procedure for pterygium excision followed by amniotic membrane transplant (AMT) adhered to the corneal and conjunctival defects using ReSure tissue sealant. Nine eyes of seven patients (age range: 28-80 years, 4 females and 3 males) underwent pterygium removal with AMT followed by adherence of tissue to the conjunctival edges with ReSure. No issues with transplant dislocation or failure and no intra- or postoperative complications were noted. No recurrences were noted during the follow-up period. ReSure may be considered as a potential sealant to adhere AMT to defective corneal and conjunctival tissues in sutureless pterygium surgery.

  14. Use of occlusal sealant in a community program and caries incidence in high- and low-risk children.

    PubMed

    Baldini, Vânia; Tagliaferro, Elaine Pereira da Silva; Ambrosano, Gláucia Maria Bovi; Meneghim, Marcelo de Castro; Pereira, Antonio Carlos

    2011-08-01

    The aims of this study were to investigate the effectiveness of sealant placement under the guidelines of the Oral Health Promotion Program for Children and Adolescents (Portugal), and to test the influence of clinical and socioeconomic variables on the DMFT increment in 277 children, born in 1997. A dental hygienist performed the initial examinations and sealant placement (Helioseal, Vivadent) on the permanent first molars in 2005. These activities were registered in dental records that were assessed in 2007. Children were classified according to caries risk at baseline [high (HR: DMFT+dmft>0); low (LR: DMFT+dmft=0) risk] and sealant placement as follows: HR-S and LR-S Groups (with sealant placement); HR-NS and LR-NS Groups (without sealant placement). A calibrated dentist performed the final examination in 2007 at school, based on the World Health Organization recommendations. The variables collected were: dental caries, visible dental plaque, malocclusions, and socioeconomic level (questionnaire sent to children's parents). For univariate (Chi-square or Fisher tests) and multivariate (Multiple logistic regression) analyses the DMFT increment >0 was selected as dependent variable. Approximately 17.0% of the children showed DMFT increment>0 (mean=0.25). High-risk children presented a significant increase in the number of decayed and/or filled teeth. These children had 7.94 more chance of developing caries. Children who did not receive sealant were 1.8 more prone to have DMFT increment >0. It appears that sealant placement was effective in preventing dental caries development. Moreover, the variables "risk" and "sealant placement" were predictors for DMFT increment in the studied children.

  15. Nondestructive spectroscopic characterization of building materials

    NASA Astrophysics Data System (ADS)

    Kassu, Aschalew; Walker, Lauren; Sanders, Rachel; Farley, Carlton; Mills, Jonathan; Sharma, Anup

    2017-04-01

    The purpose of this research project is to demonstrate the application of Raman spectroscopy technique for characterization and identification of the distinct Raman signatures of construction materials. The results reported include the spectroscopic characterization of building materials using compact Raman system with 785 nm wavelength laser. The construction materials studied include polyblend sanded grout, fire barrier sealant, acrylic latex caulk plus and white silicone. It is found that, both fire barrier sealant and acrylic latex caulk plus has a prominent Raman band at 1082 cm-1, and three minor Raman signatures located at 275, 706 and 1436 cm-1. On the other hand, sand grout has three major Raman bands at 1265, 1368 and 1455 cm-1, and four minor peaks at 1573, 1683, 1762, and 1868 cm-1. White silicone, which is a widely used sealant material in construction industry, has two major Raman bands at 482 and 703 cm-1, and minor Raman characteristic bands at 783 and 1409 cm-1.

  16. Nonmetallic materials handbook. Volume 1: Epoxy materials

    NASA Technical Reports Server (NTRS)

    Podlaseck, S. E.

    1979-01-01

    Thermochemical and other properties data is presented for the following types of epoxy materials: adhesives, coatings finishes, inks, electrical insulation, encapsulants, sealants, composite laminates, tapes, and thermal insulators.

  17. First impressions about Adherus, a new dural sealant.

    PubMed

    Zoia, Cesare; Bongetta, Daniele; Lombardi, Francesco; Custodi, Viola Marta; Pugliese, Raffaelino; Gaetani, Paolo

    2015-12-18

    The aim of the study is to report our first impressions about Adherus, a novel dural sealant, used in neurosurgical endoscopic transnasal procedures. We retrospectively reviewed the clinical and surgical records of the first 11 patients with intraoperative high-flow cerebrospinal fluid leak treated with the aid of Adherus at our center between February and October 2014. The healing at the level of the dural plasty was monitored and evaluated radiologically and with regular endoscopic inspections. With a median follow-up of 210 days, no postoperative CSF leak or surgical site infections were found in any of the cases. Based on our preliminary experience, this new dural sealant seems to provide an effective aid in dural plasty during endoscopic transphenoidal procedures.

  18. Ion release and in vitro enamel fluoride uptake associated with pit and fissure sealants containing microencapsulated remineralizing agents.

    PubMed

    Burbank, Brant D; Cooper, Ryan L; Kava, Alyssa; Hartjes, Jennifer M; McHale, William A; Latta, Mark A; Gross, Stephen M

    2017-04-01

    To determine if pit-and-fissure sealants with microencapsulated remineralizing agents with sustained release of fluoride, calcium and phosphate ions could promote enamel fluoride uptake by demineralized tooth structure. Sealants that contained 5 w/w% microcapsules with aqueous solutions of 5M Ca(NO3)2 or 0.8M NaF or 6.0M K2HPO4 or a mixture of all three were prepared. Ion release profiles were measured as a function of time. Enamel fluoride uptake by demineralized tooth structure was determined. Sustained release of fluoride, calcium and phosphate ions from a sealant was demonstrated. Fluoride uptake by demineralized enamel was significantly increased compared to a control sealant manufactured without microcapsules (P< 0.01). Bovine enamel that contained 2.2±2.1 µg F/g of enamel prior to exposure to a sealant without microcapsules had 2.3±0.5 after 90 days. Enamel exposed to sealant with 5w/% NaF microcapsules went from 3.5±3.5 µg F/g of enamel prior to exposure to 148±76 after 90 days. Enamel exposed to sealant with 2 w/w% NaF, 2 w/w% Ca(NO3)2 and 1 w/w% K2HPO4 microcapsules went from 1.7±0.7 µg F/g of enamel prior to exposure to 190±137 after 90 days. Sealants with encapsulated remineralizing agents were capable of releasing biologically available fluoride, calcium, and phosphate ions. Incorporation of these microcapsules in pit and fissure sealants is a promising method for remineralization determined by enamel fluoride uptake measurements.

  19. Short-term crack sealant performance and reducing bumps and transverse cracking in new hot mix asphalt overlays over crack sealants.

    DOT National Transportation Integrated Search

    2009-11-01

    This interim report is intended to provide preliminary information regarding the performance of crack sealants produced by three : manufacturers during a two-year period in service in three pavements in Colorado. In addition, preliminary conclusions ...

  20. [Distal Pancreatectomy with Autologous Fibrin Sealant - Implementation of an Established Concept of Tissue Sealing in Pancreatic Surgery].

    PubMed

    Luu, A M; Braumann, C; Belyaev, O; Janot, M; Uhl, W; Herzog, T

    2016-12-01

    Background: Postoperative pancreatic fistulas (POPF) remain a major concern after distal pancreatectomy. Irrespective of the technique to close the pancreatic remnant, pancreatic fistulas will occur in approximately 30 % of patients undergoing distal pancreatectomy. For the first time ever, autologous fibrin sealant (Vivostat®) was used to additionally seal the pancreatic remnant after a distal pancreatectomy. The aim was to analyse whether this changes the postoperative outcome. Patients/Material and Methods: In 2015, a technical case series was performed in 15 patients who underwent distal pancreatectomy. The pancreatic remnant was additionally sealed with autologous fibrin sealant (Vivostat®). Results: A postoperative pancreatic fistula (POPF) occurred in 5/15 patients (33 %). One patient had a POPF grade A (1/15, 6.7 %), whereas a POPF grade B occurred in 4/15 patients (26.7 %). 75 % (3/4) of the patients with a POPF grade B were sufficiently treated with antibiotics, whereas a CT-guided percutaneous drainage had to be placed only in one case. Conclusion: Autologous fibrin sealant is simple to apply and seems to be well tolerated. However, it does not seem to avoid the development of postoperative pancreatic fistulas after distal pancreatectomy. Georg Thieme Verlag KG Stuttgart · New York.

  1. Survival of atraumatic restorative treatment (ART) sealants and restorations: a meta-analysis.

    PubMed

    de Amorim, Rodrigo G; Leal, Soraya C; Frencken, Jo E

    2012-04-01

    The purpose of this study is to perform a systematic investigation plus meta-analysis into survival of atraumatic restorative treatment (ART) sealants and restorations using high-viscosity glass ionomers and to compare the results with those from the 2005 ART meta-analysis. Until February 2010, four databases were searched. Two hundred four publications were found, and 66 reported on ART restorations or sealant survival. Based on five exclusion criteria, two independent reviewers selected the 29 publications that accounted for the meta-analysis. Confidence intervals (CI) and or standard errors were calculated and the heterogeneity variance of the survival rates was estimated. Location (school/clinic) was an independent variable. The survival rates of single-surface and multiple-surface ART restorations in primary teeth over the first 2 years were 93% (CI, 91-94%) and 62% (CI, 51-73%), respectively; for single-surface ART restorations in permanent teeth over the first 3 and 5 years it was 85% (CI, 77-91%) and 80% (CI, 76-83%), respectively and for multiple-surface ART restorations in permanent teeth over 1 year it was 86% (CI, 59-98%). The mean annual dentine lesion incidence rate, in pits and fissures previously sealed using ART, over the first 3 years was 1%. No location effect and no differences between the 2005 and 2010 survival rates of ART restorations and sealants were observed. The short-term survival rates of single-surface ART restorations in primary and permanent teeth, and the caries-preventive effect of ART sealants were high. ART can safely be used in single-surface cavities in both primary and permanent teeth. ART sealants have a high caries preventive effect.

  2. Comparison of short-term in vitro fluoride release and recharge from four different types of pit-and-fissure sealants.

    PubMed

    Koga, Hiroshi; Kameyama, Atsushi; Matsukubo, Takashi; Hirai, Yoshito; Takaesu, Yoshinori

    2004-08-01

    The purpose of this in vitro study was to assess the effects of four commercial fluoride-containing pit-and-fissure sealants on caries prevention. Four sealants containing fluoride, Fuji III, Fuji III LC (GC Co., Tokyo), Teethmate F-1 (Kuraray Medical Co., Osaka) and Helioseal F (Vivadent Co., Liechtenstein) were used to investigate fluoride release and recharge. Disk-shaped specimens prepared from each material were immersed in distilled water at a temperature of 37 degrees C. After seven days, acidulated phosphate fluoride solution (APF) was applied to each specimen, and it was then again immersed in distilled water for 14 days. We then determined how much fluoride had been released into the immersing water. Fuji III LC was used with APF solution to investigate the fluoride uptake. Fuji III had the highest fluoride release, and Fuji III LC had the highest fluoride recharge. Helioseal F and Teethmate F-1 had almost no fluoride recharge. Fuji III LC/APF had a higher fluoride uptake to enamel than Fuji III LC. These results suggest that GIC-sealants in the oral cavity can serve as a fluoride reservoir and contribute to retaining a low fluoride level in oral fluids, thereby preventing caries.

  3. Comparison between self-assembling peptide nanofiber scaffold (SAPNS) and fibrin sealant in neurosurgical hemostasis.

    PubMed

    Xu, Fei-Fan; Wang, Yue-Chun; Sun, Stella; Ho, Amy S W; Lee, Derek; Kiang, Karrie M Y; Zhang, Xiao-Qin; Lui, Wai-Man; Liu, Bai-Yun; Wu, Wu-Tian; Leung, Gilberto K K

    2015-10-01

    RADA16-I is a synthetic type I self-assembling peptide nanofiber scaffold (SAPNS) which may serve as a novel biocompatible hemostatic agent. Its application in neurosurgical hemostasis, however, has not been explored. Although RADA16-I is nontoxic and nonimmunogenic, its intrinsic acidity may potentially provoke inflammation in the surgically injured brain. We conducted an animal study to compare RADA16-I with fibrin sealant, a commonly used agent, with the hypothesis that the former would be a comparable alternative. Using a standardized surgical brain injury model, 30 Sprague-Dawley rats were randomized into three treatment groups: RADA16-I, fibrin sealant or gelatin sponge (control). Animals were sacrificed on day 3 and 42. Astrocytic and microglial infiltrations within the cerebral parenchyma adjacent to the operative site were significantly lower in the RADA16-I and fibrin sealant groups than control. RADA16-I did not cause more cellular inflammatory response despite its acidity when compared with fibrin sealant. Immunohistochemical studies showed infiltration by astrocytes and microglia into the fibrin sealant and RADA16-I grafts, suggesting their potential uses as tissue scaffolds. RADA16-I is a promising candidate for further translational and clinical studies that focus on its applications as a safe and effective hemostat, proregenerative nanofiber scaffold as well as drug and cell carrier. © 2015 Wiley Periodicals, Inc.

  4. A new fibrin sealant as a three-dimensional scaffold candidate for mesenchymal stem cells

    PubMed Central

    2014-01-01

    Introduction The optimization of an organic scaffold for specific types of applications and cells is vital to successful tissue engineering. In this study, we investigated the effects of a new fibrin sealant derived from snake venom as a scaffold for mesenchymal stem cells, to demonstrate the ability of cells to affect and detect the biological microenvironment. Methods The characterization of CD34, CD44 and CD90 expression on mesenchymal stem cells was performed by flow cytometry. In vitro growth and cell viability were evaluated by light and electron microscopy. Differentiation into osteogenic, adipogenic and chondrogenic lineages was induced. Results The fibrin sealant did not affect cell adhesion, proliferation or differentiation and allowed the adherence and growth of mesenchymal stem cells on its surface. Hoechst 33342 and propidium iodide staining demonstrated the viability of mesenchymal stem cells in contact with the fibrin sealant and the ability of the biomaterial to maintain cell survival. Conclusions The new fibrin sealant is a three-dimensional scaffolding candidate that is capable of maintaining cell survival without interfering with differentiation, and might also be useful in drug delivery. Fibrin sealant has a low production cost, does not transmit infectious diseases from human blood and has properties of a suitable scaffold for stem cells because it permits the preparation of differentiated scaffolds that are suitable for every need. PMID:24916098

  5. Adhesion testing procedure for hot-poured crack sealants.

    DOT National Transportation Integrated Search

    2008-11-01

    Crack sealing is a common pavement maintenance treatment because it extends pavement service life significantly. : However, crack sealant often fails prematurely due to a loss of adhesion. Because current test methods are mostly : empirical and only ...

  6. A randomized controlled trial of cluster audit and feedback on the quality of dental sealant for rural schoolchildren.

    PubMed

    Tianviwat, S; Hintao, J; Chongsuvivatwong, V; Thitasomakul, S

    2016-03-01

    To examine whether audit and feedback could improve the quality of the application of dental sealant in rural Thai school children. A single blind, cluster randomized controlled trial was conducted. Hospital-based and school-based school sealant applied by dental nurses in Southern province of Thailand. Dental nurses and school children who received dental sealant were involved. The intervention consisted of confidential feedback of data and tailor-made problem-solving workshops. Sealant quality was measured by sealant retention and caries on sealed surfaces at six-month after sealing. The teeth examinations were done among different groups of children prior and after the intervention. After the intervention, the sealant retention rate increased dramatically in the intervention group, whereas in the control group the rate was similar to that found at baseline. The rate of caries after the intervention was stable in the intervention group and increased slightly in the control group. At the beginning of the study, the adjusted odds ratio of complete sealant retention between the intervention and control group was 0.47 which increased to 1.99 at the end of the study. However, no effect on caries on sealed surfaces was observed. The intensive focus on actual problems during the audit and feedback improved the dental nurses' performance and the quality of the dental service, although it had no statistical impact on the incidence of caries.

  7. Bond Strength of a Bisphenol-A-Free Fissure Sealant With and Without Adhesive Layer under Conditions of Saliva Contamination.

    PubMed

    Mesquita-Guimarães, Késsia Suênia Fidelis de; Sabbatini, Iliana Ferraz; Almeida, Cintia Guimarães de; Galo, Rodrigo; Nelson-Filho, Paulo; Borsatto, Maria Cristina

    2016-01-01

    Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.

  8. A Chitosan-Based Sinus Sealant for Reduction of Adhesion Formation in Rabbit and Sheep Models

    PubMed Central

    Medina, Jennifer G.; Steinke, John W.; Das, Subinoy

    2013-01-01

    Objective Chronic sinusitis is the most prevalent chronic disease in the United States in adults aged 18 to 44 years, with approximately 250,000 operations performed annually. Although often successful, sinus surgery fails in greater than 15% of patients. Adhesion formation is a common complication and cause for subsequent revision surgery. Here, the authors evaluate a sprayable chitosan/starch-based sinus sealant and demonstrate its ability to reduce adhesion formation both in vitro and in 2 animal models. Study Design Randomized, controlled, animal trials. Setting Academic medical center (fibroblast experiments) and animal laboratories (sheep and rabbit studies). Subjects and Methods This sinus sealant was applied to human cultured fibroblasts obtained from surgically removed polyps to examine its ability to inhibit fibroblast migration and proliferation. The sinus sealant was applied to New Zealand White rabbits (n = 20) in an established cecal-sidewall abrasion model and to sheep (n = 10) in a sinus surgical adhesion model to examine its ability to reduce adhesion formation. Results This sinus sealant inhibited migration and proliferation of human cultured fibroblasts and reduced the total adhesion score from 4.9 to 0.3 for a total reduction of 94% (95th percentile confidence interval [CI], 78%, 100%; P < .001) in a well-established rabbit cecal-sidewall model commonly used for adhesion testing. Moreover, this sealant reduced adhesion formation from 80% to 10% for a total reduction of 70% (95th percentile CI, 57%, 93%; P = .003) in a sheep sinus adhesion surgical model. Conclusion This chitosan-based sealant demonstrates promise for reducing adhesion formation in sinus surgery. PMID:22492298

  9. Use of fibrin sealants for the localized, controlled release of cefazolin

    PubMed Central

    Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.

    2006-01-01

    Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573

  10. Effect of artificial aging on the bond durability of fissure sealants.

    PubMed

    Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex

    2013-06-01

    To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p < 0.05). Longer thermocycling (10,000 cycles) resulted in more decreases in µTBS for group PEL and PPC, while the strength of the UX group remained relatively unchanged. After thermocycling, considerable silver penetration could be seen at the sealant/enamel interface of the EL group in micro-CT images. The etch-and-rinse procedure for sealant application promotes higher bond strength under artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.

  11. Construction and monitoring of thin overlay and crack sealant test sections at the Pecos test track.

    DOT National Transportation Integrated Search

    2014-10-01

    In this project, several crack sealant sections were constructed at the Pecos RTC. Six different sealants were : applied in routed and non-routed configurations on both older and newer pavement. The following summer, : the sections were revaluated in...

  12. Caries-preventive effect of fissure sealant containing surface reaction-type pre-reacted glass ionomer filler and bonded by self-etching primer.

    PubMed

    Shimazu, Kisaki; Ogata, Kiyokazu; Karibe, Hiroyuki

    2012-01-01

    We aimed to evaluate the caries-preventive effect of a fissure sealant containing surface reaction-type pre-reacted glass ionomer (S-PRG) filler and bonded by self-etching primer versus those of 2 conventional resin-based sealants bonded by acid etching in terms of its impact on enamel demineralization and remineralization, enamel bond strength, and integrity of debonded enamel surfaces. Demineralization, remineralization, and bond strength on untreated enamel and enamel subsurface lesions of bovine incisors were assessed among the sealants by polarizing microscopy and microradiography; debonded enamel surfaces were examined by scanning electron microscopy. The conventional resin-based sealants bonded by acid etching caused surface defects on the enamel subsurface lesions and significantly increased the lesion depth (p = 0.014), indicative of enamel demineralization. However the S-PRG filler-containing sealant bonded by self-etching primer maintained the enamel surface integrity and inhibited enamel demineralization. No difference in bond strength on both untreated enamel and enamel subsurface lesions was noted among the sealants. An S-PRG filler-containing fissure sealant bonded by self-etching primer can prevent enamel demineralization, microleakage, and gaps without the tags created by acid etching regardless of the enamel condition. Such sealants are suitable for protecting the pits and fissures of immature permanent teeth.

  13. Copolymer sealant compositions and method for making

    NASA Technical Reports Server (NTRS)

    Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)

    2002-01-01

    Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.

  14. Copolymer sealant compositions and method for making

    NASA Technical Reports Server (NTRS)

    Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)

    2004-01-01

    Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.

  15. Copolymer sealant compositions and method for making

    NASA Technical Reports Server (NTRS)

    Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)

    2003-01-01

    Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.

  16. The prevalence of dental caries and fissure sealants in 12 year old children by disadvantaged status in Dublin (Ireland).

    PubMed

    Sagheri, D; McLoughlin, J; Clarkson, J J

    2009-03-01

    The aim was to record dental caries levels and the presence of fissure sealants in 12-year-old schoolchildren whose domestic water supply had been fluoridated since birth in Dublin (Ireland). Cross-sectional study. Participants A representative, random sample of 12-year-old schoolchildren in north-west Dublin. Dental caries levels were recorded using WHO criteria and fissure sealant was recorded when sealant was detectable on a permanent molar tooth. Medical card ownership, as a surrogate for disadvantage, was recorded by use of a questionnaire. Three-hundred and thirty-two (332) children were examined. The mean DMFT was 0.80 (SD 1.24). Analysis (Mann-Whitney U test) based on stratification of the sample according to medical-card status revealed no statistically significant difference between DMFT median scores of children of medical-card holders (i.e., social disadvantage background) and non medical-card holders (p-value = 0.23). However, the data revealed a social gradient in the presence of at least one fissure sealant. Approximately 10% more children in the group of medical-card holders had no fissure sealants present. Fisher's exact test was used to examine the association between the absence of fissure sealants and at least one fissure sealant between the two groups and was considered to be statistically significant (p-value = 0.04). This study demonstrated a social gradient in the presence of fissure sealants, but no such gradient in dental caries levels. This demonstrates the importance of population-based measures in the prevention of dental caries, such as water fluoridation, in reducing oral health inequalities.

  17. The utilization of dental hygiene students in school-based dental sealant programs.

    PubMed

    Miller, Faith Y

    2005-01-01

    Early detection of childhood caries is important to childrens' overall health. Untreated childhood caries can lead to pain, as in abscesses from prolonged neglect; altered dietary intake; and delays in the development of the permanent teeth if the primary teeth are prematurely lost. In the summer of 2000, funds were provided to various oral health care provider organizations by the Illinois Department of Public Health, Division of Oral Health, to purchase portable equipment to deliver preventive services (i.e., exams, sealants, and oral hygiene education) to second-grade and sixth-grade children who qualified for Medicaid and/or free and reduced-cost lunch programs. The Dental Sealant Grant Program at Southern Illinois University in Carbondale was a unique program that utilized dental hygiene students as the primary human resource. Within the state, the Dental Sealant Grant Program was, at the time of this report, the only grantee sponsored by a stand-alone dental hygiene program (not affiliated with a dental school). Other positive aspects of the dental hygiene-sponsored sealant program were that the supervising dentist was the primary Medicaid provider and a member of the dental hygiene faculty; dental hygiene faculty participated actively as site coordinators and clinicians; and dental hygiene students were given the opportunity to volunteer for the program as a service-learning option.

  18. Behavior of stress generated in semiconductor chips with high-temperature joints: Influence of mechanical properties of joint materials

    NASA Astrophysics Data System (ADS)

    Ito, H.; Kuwahara, M.; Ohta, R.; Usui, M.

    2018-04-01

    High-temperature joint materials are indispensable to realizing next-generation power modules with high-output performance. However, crack initiation resulting from stress concentration in semiconductor chips joined with high-temperature joint materials remains a critical problem in high-temperature operation. Therefore, clarifying the quantitative influence of joint materials on the stress generated in chips is essential. This study investigates the stress behavior of chips joined by Ni-Sn solid-liquid interdiffusion (SLID), which results in a high-temperature joint material likely to generate cracks after joining or when under thermal cycling. The results are compared with those fabricated using three types of solders, Pb-10%Sn, Sn-0.7%Cu, and Sn-10%Sb (mass %), which are conventional joint materials with different melting points and mechanical properties. Using Ni-Sn SLID results in the generation of high compressive stress (500 MPa) without stress relaxation after the joining process in contrast to the case of solders in which the compressive stresses are low (<300 MPa) and decrease to still lower levels (<250 MPa). In addition, no stress relaxation occurs during thermal cycling when using Ni-Sn SLID, whereas stress relaxation is clearly observed during heating to 200 °C using solders. Different stress behaviors between Ni-Sn SLID and other joint materials are illustrated by their mechanical strength and resistance against plastic and creep deformation. These results suggest that stress relaxation in a chip is key in suppressing crack initiation in highly reliable modules during high-temperature operation.

  19. Materials testing protocol for small joint prostheses.

    PubMed

    Savory, K M; Hutchinson, D T; Bloebaum, R

    1994-10-01

    In this article, a protocol for the evaluation of new materials for small joint prostheses is introduced. The testing methods employed in the protocol were developed by reviewing reported clinical failure modes and conditions found in vivo. The methods developed quantitatively evaluates the fatigue, fatigue crack propagation, and wear resistance properties of materials. For this study, a silicone elastomer similar to Dow Corning Silastic HP100, a radiation stable polypropylene, and a copolymer of polypropylene and ethylene propylene-diene monomer (EPDM) are evaluated. None of the materials tested demonstrated the ideal properties that are sought in a self-hinging joint prostheses. The silicone elastomer had excellent wear properties; however, cracks quickly propagated, causing catastrophic failure when fatigued. Conversely, the copolymer showed excellent fatigue crack propagation resistance and less than favorable wear properties. The polypropylene did not perform well in any evaluation.

  20. Effects of subpressure on the sealing ability of dental sealant in vitro.

    PubMed

    Tian, Y M; Zhuge, R S; Zhang, Z T; Zheng, D X; Ding, N; Li, Y M

    2018-06-06

    Pits and fissures sealing with flowable materials is a popular method for preventing caries in preventive dentistry while there is still microleakage existed. This in vitro study aimed to explore the effects of subpressure technique on the sealing ability of pit and fissure sealant. One hundred and forty-one extracted human premolars were collected in this study and treated with different pressure (atmosphere pressure as group C, -0.04 MPa as group S 4 and -0.08 MPa as group S 8 ). Thermocycling (×5000) was also performed. Penetration percentage, microleakage, cross-sectional microhardness (Knoop, KMH) and mineral loss were evaluated. Kappa tests, Friedman nonparametric and two-way ANOVA were used for data analysis. Penetration percentages of group S 4 and S 8 were significant higher compared to that of group C. Microleakage of groups was similar before thermocycling, while subpressure groups showed lower scale of microleakage after thermocycling. Data of KMH and mineral loss showed significant differences between subpressure and thermocycling groups. Subpressure technique could increase the penetration of pit and fissure sealant, decrease microleakage and increase resistance of demineralization after thermocycling. This novel technique may have great potential for preventing from secondary caries. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Use of a hydrogel sealant in epithelial ingrowth removal after laser in situ keratomileusis.

    PubMed

    Ramsook, Sandhya S; Hersh, Peter S

    2015-12-01

    We describe 2 cases in which clinically significant epithelial ingrowth was removed by debridement and followed by the use of a hydrogel sealant (Resure) to seal the flap edge. In both cases, the epithelial ingrowth was seen after otherwise uneventful laser in situ keratomileusis retreatment. The visual outcomes were good with no recrudescence of interface epithelium. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. A reversible thermoresponsive sealant for temporary closure of ocular trauma.

    PubMed

    Bayat, Niki; Zhang, Yi; Falabella, Paulo; Menefee, Roby; Whalen, John J; Humayun, Mark S; Thompson, Mark E

    2017-12-06

    Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N -isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat-induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injuries. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  3. New generation tissue sealants and hemostatic agents: innovative urologic applications.

    PubMed

    Traver, Michael A; Assimos, Dean G

    2006-01-01

    Control of blood loss during urologic surgery is paramount to the success of patient recovery. Hemostatic agents and tissue sealants are used routinely to prevent excess blood loss and in reconstruction during surgical repair. Some of the available products include thrombin sealant, fibrin glue, bovine serum/albumin/glutaraldehyde, and gelatin matrix. Each of these agents differs in mechanism, cost, and application. Complications can include allergic reactions or thromboembolism and the risk of contracting bovine spongiform encephalitis or hepatitis. Many new hemostatic agents are being developed and approved. The benefits and risks of use of these agents versus conventional treatment need to be considered on a case-by-case basis by the surgeon.

  4. Failure of dissimilar material bonded joints

    NASA Astrophysics Data System (ADS)

    Konstantakopoulou, M.; Deligianni, A.; Kotsikos, G.

    2016-03-01

    Joining of materials in structural design has always been a challenge for engineers. Bolting and riveting has been used for many years, until the emergence of fusion welding which revolutionised construction in areas such as shipbuilding, automotive, infrastructure and consumer goods. Extensive research in the past 50 years has resulted in better understanding of the process and minimised the occurrence of failures associated with fusion welding such as, residual stress cracking, stress corrosion and corrosion fatigue cracking, localised reduction in mechanical properties due to microstructural changes (heat affected zone) etc. Bonding has been a technique that has been proposed as an alternative because it eliminates several of the problems associated with fusion welding. But, despite some applications it has not seen wide use. There is however a renewed interest in adhesively bonded joints, as designers look for ever more efficient structures which inevitably leads to the use and consequently joining of combinations of lightweight materials, often with fundamentally different mechanical and physical properties. This chapter provides a review of adhesively bonded joints and reports on improvements to bonded joint strength through the introduction of carbon nanotubes at the bond interface. Results from various workers in the field are reported as well as the findings of the authors in this area of research. It is obvious that there are several challenges that need to be addressed to further enhance the strength of bonded joints and worldwide research is currently underway to address those shortcomings and build confidence in the implementation of these new techniques.

  5. Validation of hot-poured crack sealant performance-based guidelines.

    DOT National Transportation Integrated Search

    2017-06-01

    This report summarizes a comprehensive research effort to validate thresholds for performance-based guidelines and : grading system for hot-poured asphalt crack sealants. A series of performance tests were established in earlier research and : includ...

  6. Construction Productivity Advancement Research (CPAR) Program: Improved Materials and Processes for Sealing and Resealing Joints in Portland Cement Concrete Pavements - Field Evaluation

    DTIC Science & Technology

    1993-10-01

    sealant was determined by noting the type and number of defects each sealant incurred. Figure 4 provides a sample evaluation sheet used dur- ing the field...was conducted by visually inspect- ing the mater~al for defects . If any defects were noted, the type of defect was described and the quant~ty of that... defect was measured. The quantity of the defect was dividted by the total quantity of sealant and the result reported as percent defect . Adhesion and

  7. Systematic review and meta-analysis of haemostatic and biliostatic efficacy of fibrin sealants in elective liver surgery.

    PubMed

    Sanjay, Pandanaboyana; Watt, David G; Wigmore, Stephen J

    2013-04-01

    Fibrin sealants are frequently used in liver surgery to achieve intraoperative haemostasis and reduce post-operative haemorrhage and bile leak. This meta-analysis aimed to review the haemostatic and biliostatic capacity of fibrin sealants in elective liver surgery. An electronic search was performed on the MEDLINE, Embase and PubMed databases using both subject headings and truncated word searches to identify all published articles that are related to this topic. Pooled risk ratios were calculated for categorical outcomes, and mean differences for secondary continuous outcomes, using the fixed-effects and random-effects models for meta-analysis. Ten randomised controlled trials encompassing 1,225 patients were analysed to achieve a summated outcome. Pooled data analysis showed the use of fibrin sealants resulted in reduced time to haemostasis (mean difference -3.45 min [-3.78, -3.13] (P < 0.00001)) and increased numbers of patients with complete haemostasis (risk ratio 1.56, 95 % confidence interval 1.04-2.34, p = 0.03) when compared to controls. The use of fibrin sealants did not influence perioperative blood transfusion requirements, bile leak rates, post-operative haemorrhage, intra-abdominal collections and overall morbidity and mortality compared with controls. There is no solid evidence that the routine use of fibrin sealants reduces the incidence of post-operative haemorrhage or bile leak compared with other treatments. The use of fibrin sealants may reduce the time to haemostasis, but this does not translate to improved perioperative outcomes.

  8. Retention of fissure sealants using two different methods of application in teeth with hypomineralised molars (MIH): a 4 year clinical study.

    PubMed

    Lygidakis, N A; Dimou, G; Stamataki, E

    2009-12-01

    This was to evaluate the retention rate of fissure sealants applied to MIH molars with occlusal enamel opacities, using two different application methods after 4 years. 54 children exhibiting molars with MIH aged 6-7 years, participated in the study. presence of at least 2 fully erupted caries-free maxillary or mandibular first permanent molars in the opposite sides of the mouth, both with occlusal enamel opacities without breakdown. Following parental consent, sealants were applied using a half-mouth experimental design. Group A: On a randomly assigned first molar on one side of the mouth sealants Fissurit were placed using a single bottle adhesive system (One-step prior to sealant application. Group B: Sealants were applied on the contra-lateral molar using the conventional etch and seal technique. Children were seen biannually when a preventive program was applied, without replacing any lost sealant. After 4 years, 47 sets of molars (94 teeth) were available for blind evaluation. Teeth in Group A presented a better retention rate; 70.2% were fully sealed, 29.7% partly sealed and none unsealed (lost sealant). Group B revealed 25.5% fully sealed, 44.6% partly sealed and 29.7% unsealed teeth. Differences between groups A and B were statistically significant (p<0.001). Also both groups revealed a decreasing retention rate over the 4-year period (p<0.001). There was no difference in dental caries increment rate and enamel breakdowns at the end of the study (p>0.01). In hypomineralised molars with occlusal opacities sealants appear to have greater retention when applied using 5th generation adhesive systems prior to sealant.

  9. Effectiveness of fluoride sealant in the prevention of carious lesions around orthodontic brackets: an OCT evaluation

    PubMed Central

    Pithon, Matheus Melo; Santos, Mariana de Jesus; de Souza, Camilla Andrade; Leão, Jorge César Borges; Braz, Ana Karla Souza; de Araujo, Renato Evangelista; Tanaka, Orlando Motohiro; Oliveira, Dauro Douglas

    2015-01-01

    Abstract Objective: This article aimed to evaluate in vitro the efficiency of Pro Seal fluoride sealant application in the prevention of white spot lesions around orthodontic brackets. Material and Methods: Brackets were bonded to the buccal surface of bovine incisors, and five groups were formed (n = 15) according to the exposure of teeth to oral hygiene substances and the application of enamel sealant: G1 (control), only brushing was performed with 1.450 ppm fluoride; G2 (control) brushing associated with the use of mouthwash with 225 ppm fluoride; G3, only Pro Seal sealant application was performed with 1.000 ppm fluoride; G4 Pro Seal associated with brushing; G5 Pro Seal associated with brushing and mouthwash. Experimental groups alternated between pH cycling and the procedures described. All specimens were kept at a temperature of 37 °C throughout the entire experiment. Both brushing and immersion in solutions were performed within a time interval of one minute, followed by washing in deionized water three times a day for 28 days. Afterwards, an evaluation by Optical Coherence Tomography (OCT) of the spectral type was performed. In each group, a scanning exam of the white spot lesion area (around the sites where brackets were bonded) and depth measurement of carious lesions were performed. Analysis of variance (ANOVA) was applied to determine whether there were significant differences among groups. For post hoc analysis, Tukey test was used. Results: There was statistically significant difference between groups 1 and 2 (p = 0.003), 1 and 3 (p = 0.008), 1 and 4 (p = 0.000) and 1 and 5 (p = 0.000). The group in which only brushing was performed (Group 1) showed deeper enamel lesion. Conclusion: Pro Seal sealant alone or combined with brushing and/or brushing and the use of a mouthwash with fluoride was more effective in protecting enamel, in comparison to brushing alone. PMID:26691968

  10. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases.

    PubMed

    Siman, Homayoun; Techy, Fernando

    2016-02-01

    Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT.

  11. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases

    PubMed Central

    Siman, Homayoun; Techy, Fernando

    2015-01-01

    Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT. PMID:26835216

  12. European Fissure Sealant Guidelines: assessment using AGREE II.

    PubMed

    San Martin-Galindo, L; Rodríguez-Lozano, F J; Abalos-Labruzzi, C; Niederman, R

    2017-02-01

    Pit and fissure sealants are effective in reducing the incidence of occlusal caries, and multiple clinical practice guidelines (CPGs) have been developed for recommending their proper use. The usefulness of CPGs depends on their quality and on the rigour of the guideline development process. A study was made to assess the quality of current European CPGs based on the Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument, which uses 23 key items rated on a 7-point scale to assess practice guideline development and the quality of reporting. A search was conducted for fissure sealant guidelines for preventing caries in children and adults at high and low risk published in the last 10 years. Calibration was carried out before scoring to assess agreement between the appraisers using the AGREE II instrument. The searches identified 19 relevant guidelines, and following application of the inclusion/exclusion criteria, three guidelines were retained for evaluation. The proportion of observed agreement was calculated, expressed by the agreement separately for positive and negative ratings (PA = 0.89, NA = 0-91). The results of the guideline assessments revealed the highest score for the Irish guideline, a moderate score for the French guideline and the lowest score for the European guideline. Based on the AGREE II instrument, the results obtained show significant variation in the quality assessment of the three European Fissure Sealant Guidelines. Future studies should be carried out both to develop quality dental CPGs and to investigate effective ways of adopting them. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...

  14. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...

  15. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    PubMed

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  16. Sealed head access area enclosure

    DOEpatents

    Golden, Martin P.; Govi, Aldo R.

    1978-01-01

    A liquid-metal-cooled fast breeder power reactor is provided with a sealed head access area enclosure disposed above the reactor vessel head consisting of a plurality of prefabricated structural panels including a center panel removably sealed into position with inflatable seals, and outer panels sealed into position with semipermanent sealant joints. The sealant joints are located in the joint between the edge of the panels and the reactor containment structure and include from bottom to top an inverted U-shaped strip, a lower layer of a room temperature vulcanizing material, a separator strip defining a test space therewithin, and an upper layer of a room temperature vulcanizing material. The test space is tapped by a normally plugged passage extending to the top of the enclosure for testing the seal or introducing a buffer gas thereinto.

  17. Withstand pressure of a simple fibrin glue sealant: experimental study of mimicked sellar reconstruction in extended transsphenoidal surgery.

    PubMed

    Oshino, Satoru; Saitoh, Youichi; Yoshimine, Toshiki

    2010-06-01

    To examine the strength and tolerance of the fibrin glue sealant in a situation of extended transsphenoidal surgery. The withstand pressure of fibrin glue sealant was measured using a simple sellar reconstruction model. A 15-mm diameter hole at the bottom of a 51-cm high cylinder was covered with a Gore-Tex (Gore-Tex, Tokyo, Japan) sheet. A small plate was placed on the center for a brief fixation, and 3 mL of fibrin glue was applied over the entire bottom. Then water was gradually filled in five cylinders, and the water level at leakage was measured as withstand pressures at 10 minutes and 24 hours after sealant application. The stability of the sealant under pressures of 20 and 30 cm H(2)O for 12 hours was also examined. The median initial withstand pressure at 10 minutes was 32 cm H(2)O (n = 5), and was significantly increased to 47.5 cm H(2)O after 24 hours (n = 4). In four of five cylinders, fibrin glue sealants were stable against a pressure of 20 cm H(2)O for 12 hours and 30 cm H(2)O for the next 12 hours. The withstand pressure of simple fibrin glue sealant without other biological reactions could be estimated to be more than 20 cm H(2)O after application, and increased to more than 40 cm H(2)O after 24 hours. These data are practical for neurosurgeons to comprehend the strength and limit of fibrin glue sealant and suggests the importance to control the intracranial pressure to less than 20 cm H(2)O, especially for the first 12 to 24 hours. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Interactions between F-111 Fuselage Fuel Tank Sealants. Part I. Characterisation of Polyester Sealants and their Hydrolytic Degradation Products,

    DTIC Science & Technology

    1983-12-01

    maleic acid , adipic acid , azelaic acid and suberic acid . To ensure complete esterification during the exhaustive degradation reactions, an...spectroscopic techniques. Major components were shown to be sebacic acid and neopentyl glycol. The most significant difference between the two polyester...and acid equivalent weights of the prepolymers, their hydrolysis products and hydrolysed cured sealants were determined to assess extent of degradation

  19. A randomized prospective multicenter trial of a novel vascular sealant.

    PubMed

    Stone, William M; Cull, David L; Money, Samuel R

    2012-11-01

    Increasing use of anticoagulant medications, particularly antiplatelet therapies, can increase the difficulty in obtaining adequate suture line hemostasis. Multiple vascular sealants have been used as adjuncts to surgical procedures, but none of them have been universally successful. The aim of this study was to evaluate the safety and effectiveness of a new prophylactic vascular sealant in arterial surgery. A randomized prospective multi-institutional trial was undertaken comparing ArterX Vascular Sealant (AVS) with Gelfoam Plus during open arterial reconstruction. Three hundred thirty-one anastomotic sites in 217 patients were randomized. One hundred one of 167 (60.5%) anastomotic sites in the AVS group achieved immediate hemostasis compared with 65 of 164 (39.6%) in the control group (P = 0.001). In anastomoses with polytetrafluoroethylene grafts, 105 of 167 (62.5%) in the AVS group achieved immediate hemostasis compared with 56 of 164 (34.0%) in the control group (P < 0.001). No significant differences were noted in morbidity or mortality. Operative time was significantly less in the AVS group compared with the control group (3.2 vs. 3.8 hours, P < 0.01). Use of AVS results in superior hemostatic effectiveness compared with Gelfoam Plus, with no difference in safety. Although no cost analysis was performed, cost savings likely resulted from significantly decreased operative time. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  20. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak

    PubMed Central

    Erşen, Ezel; Demirkaya, Ahmet; Kara, H. Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-01-01

    Background Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. Methods A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Results Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Conclusions Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery. PMID:29221263

  1. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak.

    PubMed

    Kılıç, Burcu; Erşen, Ezel; Demirkaya, Ahmet; Kara, H Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-09-01

    Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery.

  2. Microhardness evaluation of enamel adjacent to an improved GIC sealant after different enamel pre-treatment procedures.

    PubMed

    Haznedaroglu, E; Sozkes, S; Mentes, A R

    2014-12-01

    This in vitro study was carried out to evaluate the microhardness of enamel adjacent to a glass ionomer cement (GIC) with high fluoride content used as a sealant (Fuji Triage, GC Corp., Japan) after laser, bur or air abrasion treatment procedures. 200 freshly extracted non-carious human molars were divided into 10 experimental groups according to the enamel pre-treatment method: A air abrasion (Mach 4.1 Kreativ Inc., USA); AP, Air abrasion + conditioning with 20% polyacrylic acid (GC cavity conditioner); L, Er,Cr:YSGG laser application (Waterlase, Biolase Technology, Inc., San Clemente, USA); LP, Er,Cr:YSGG laser application and fissure conditioning; B, ameloplasty carried out with a diamond bur especially designed for preparing fissures (Komet #8833); BP, ameloplasty + fissure conditioning; P, application of 20% polyacrylic acid and all fissures sealed with GIC; C, no fissure treatment, the material was applied directly to the fissures (control); R, application of 37% orthophosphoric acid and fissures sealed with a resin-based sealant (Fissurit; Voco, Germany) (control); N, no treatment (control). Half of each group of teeth were left in artificial saliva for one month and the rest for three months. The teeth were then sectioned and microhardness was measured using a Vickers test apparatus. Kruskal-Wallis, Mann-Whitney U and Dunn's multiple comparison tests were carried out (5% significance). After one month results regarding hardness at the base and lateral walls of fissures were significantly higher in groups A, AP, L, LP, B, BP, P and C than in groups R and N (p<0.01), but no difference was seen between the treatment procedures. The results after three months produced similar findings with evenly increased values for all groups. The results of this study showed that the tested GIC with a higher fluoride content seemed to improve the enamel hardness of the fissure enamel and could be regarded as an alternative material in cases where resin sealant applications

  3. Cryogenic adhesives and sealants: Abstracted publications

    NASA Technical Reports Server (NTRS)

    Williamson, F. R.; Olien, N. A.

    1977-01-01

    Abstracts of primary documents containing original experimental data on the properties of adhesives and sealants at cryogenic temperatures are presented. The most important references mentioned in each document are cited. In addition, a brief annotation is given for documents considered secondary in nature, such as republications or variations of original reports, progress reports leading to final reports included as primary documents, and experimental data on adhesive properties at temperatures between about 130 K and room temperature.

  4. Evaluating cyclic fatigue of sealants during outdoor testing

    Treesearch

    R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White

    2009-01-01

    A computer-controlled test apparatus (CCTA) and other instrumentation for subjecting sealant specimens to cyclic fatigue during outdoor exposure was developed. The CCTA enables us to use weather-induced conditions to cyclic fatigue specimens and to conduct controlled tests in-situ during the outdoor exposure. Thermally induced dimensional changes of an aluminum bar...

  5. Determining ultra-low moisture permeation measurement for sealants on OLED encapsulation

    NASA Astrophysics Data System (ADS)

    Choi, Byung Il; Woo, Sang Bong; Kim, Jong Chul; Kim, Seung Hun; Seo, Sang Joon

    2012-12-01

    As the next-generation flexible display elements are very vulnerable to moisture, securing proper encapsulation is a decisive factor in enabling a long working life. Therefore, together with the recent development of plastic barrier films with very low permeabilities, interest in the permeabilities of sealants used for perimetric sealing has been increasing. In this study, equipment with a resolution of approximately ˜10-7 g·day-1 to measure moisture permeability in perimetric sealing was established, and the permeabilities of different sealants were measured. This equipment could have applications not only in the display industry but also in other sectors requiring encapsulation technology, such as the semiconductor and solar cell industries.

  6. Studies of new perfluoroether elastomeric sealants. [for aircraft fuel tanks

    NASA Technical Reports Server (NTRS)

    Basiulis, D. I.; Salisbury, D. P.

    1981-01-01

    Channel and filleting sealants were developed successfully from cyano and diamidoxime terminated perfluoro alkylene ether prepolymers. The prepolymers were polymerized, formulated and tested. The polymers and/or formulations therefrom were evaluated as to their physical, mechanical and chemical properties (i.e., specific gravity, hardness, nonvolatile content, corrosion resistance, stress corrosion, pressure rupture resistance, low temperature flexibility, gap sealing efficiency, tensile strength and elongation, dynamic mechanical behavior, compression set, fuel resistance, thermal properties and processability). Other applications of the formulated polymrs and incorporation of the basic prepolymers into other polymeric systems were investigated. A cyano terminated perfluoro alkylene oxide triazine was formulated and partially evaluated. The channel sealant in its present formulation has excellent pressure rupture resistance and surpasses present MIL specifications before and after fuel and heat aging.

  7. Subclinical and clinical mastitis in heifers following the use of a teat sealant precalving.

    PubMed

    Parker, K I; Compton, C; Anniss, F M; Weir, A; Heuer, C; McDougall, S

    2007-01-01

    This study investigated the effect in heifers of infusion of a bismuth subnitrate teat-canal sealant and bacterial intramammary infection (IMI) precalving on prevalence of postcalving IMI and incidence of clinical mastitis in the first 2 wk postcalving. Glands (n = 1,020) from heifers (n = 255) in 5 seasonally calving, pasture-fed dairy herds were randomly assigned within heifer to 1 of 4 treatment groups (no treatment; mammary gland secretion collection; infusion of a teat sealant; or sample collection with infusion of teat sealant). Heifers within a herd were enrolled on one calendar day, 31 d on average before the planned start of the seasonal calving period. Duplicate milk samples were collected from each gland within 4 d after calving for bacterial culture. Herd owners collected duplicate milk samples, before treatment, for bacterial culture from glands they defined as having clinical mastitis. The gland prevalence of IMI precalving was 15.5% and did not differ between herds. Bacteria isolated precalving included coagulase-negative staphylococci (76.9% of all bacteriologically positive samples), Streptococcus uberis (14.1%), Staphylococcus aureus (5.1%), Corynebacterium spp. (3.8%), and others (0.1%). The presence of an IMI precalving increased the risk of an IMI postcalving 3.6-fold and the risk of clinical mastitis 4-fold, relative to no IMI precalving. Infusion of the teat sealant reduced the risk of postcalving IMI due to Strep. uberis by 84%, and of clinical mastitis by 68%. Sampling the glands precalving had no effect on postcalving IMI or on clinical mastitis incidence. Use of an internal teat canal sealant in heifers precalving may be a useful tool for reducing the risk of subclinical and clinical mastitis in heifers.

  8. Noninvasive pit and fissure sealing: microtensile bond strength to intact bovine enamel of different pit and fissure sealants in a simplified fissure model.

    PubMed

    Papacchini, Federica; Cury, Alvaro H; Goracci, Cecilia; Chieffi, Nicoletta; Tay, Franklin R; Polimeni, Antonella; Ferrari, Marco

    2006-12-01

    To measure the microtensile bond strength of different pit and fissure sealants in a simplified fissure model. Twenty extracted bovine mandibular permanent incisors were randomly divided into 4 groups for treatment: G1: 35% phosphoric acid/Clinpro Sealant; G2: 35% phosphoric acid/Delton; G3: Non-Rinse Conditioner/Dyract Seal; G4: 20% polyacrylic acid/Fuji IILC. Each tooth was sectioned into 6 pieces (4 x 6 mm) of buccal enamel. SEM examination was used to confirm the presence of aprismatic enamel on each tooth. Using a spacer, two pieces of etched enamel were secured to a glass slide at a mean distance of 0.6+/-0.1 mm. The space between enamel substrates was then etched/conditioned and sealed with different materials according to the tested groups. By serially cutting each double-bonded sample, multiple beam-shaped specimens about 0.8mm(2) in cross section were obtained and tested in tension (0.5 mm/min) until failure occurred at either one of the two stressed interfaces. Failure modes were classified by stereomicroscopy. G1 and G2 showed statistically higher bond strengths than G3 and G4. G4 demonstrated the significantly lowest bond strength. Failures were mostly adhesive in G1, G2, G3, and mainly cohesive/mixed in G4. According to this model, resin-based materials (Clinpro Sealant, Delton) showed better microtensile bond strength than compomer (Dyract Seal) or resin-modified glass ionomer (Fuji IILC).

  9. Collagen sealant patch to reduce lymphatic drainage after lymph node dissection.

    PubMed

    Di Monta, Gianluca; Caracò, Corrado; Crispo, Anna; Marone, Ugo; Mozzillo, Nicola

    2012-12-19

    Seroma formation is a frequent complication following radical lymph node dissection (RLND) in patients with metastatic melanoma. Several strategies have been used to prevent fluid accumulation and thereby reduce the duration of postoperative drainage, including fibrin sealants. This was a prospective, single-center study in which consecutive patients undergoing surgical treatment of stage III metastatic melanoma by axillary or ilio-inguinal RLND were randomized to receive standard treatment plus fibrinogen/thrombin-coated collagen sealant patch (CSP) or standard treatment alone. The primary endpoint of the study was postoperative duration of drainage. A total of 70 patients underwent axillary (n = 47) or ilio-inguinal (n = 23) RLND and received CSP plus standard treatment (n = 37) or standard treatment alone (n = 33). Mean duration of drainage was significantly reduced in the CSP group compared with standard treatment (ITT analysis: 20.1 ± 5.1 versus 23.3 ± 5.1 days; p = 0.010). The percentage of patients drainage-free on day 21 was significantly higher in the CSP group compared with the standard treatment group (86% versus 67%; p = 0.049). Use of the tissue sealant resulted in a significant reduction in duration of drainage. Further studies are warranted to confirm these results in different and selected types of lymphadenectomy.

  10. Collagen sealant patch to reduce lymphatic drainage after lymph node dissection

    PubMed Central

    2012-01-01

    Background Seroma formation is a frequent complication following radical lymph node dissection (RLND) in patients with metastatic melanoma. Several strategies have been used to prevent fluid accumulation and thereby reduce the duration of postoperative drainage, including fibrin sealants. Methods This was a prospective, single-center study in which consecutive patients undergoing surgical treatment of stage III metastatic melanoma by axillary or ilio-inguinal RLND were randomized to receive standard treatment plus fibrinogen/thrombin-coated collagen sealant patch (CSP) or standard treatment alone. The primary endpoint of the study was postoperative duration of drainage. Results A total of 70 patients underwent axillary (n = 47) or ilio-inguinal (n = 23) RLND and received CSP plus standard treatment (n = 37) or standard treatment alone (n = 33). Mean duration of drainage was significantly reduced in the CSP group compared with standard treatment (ITT analysis: 20.1 ± 5.1 versus 23.3 ± 5.1 days; p = 0.010). The percentage of patients drainage-free on day 21 was significantly higher in the CSP group compared with the standard treatment group (86% versus 67%; p = 0.049). Conclusions Use of the tissue sealant resulted in a significant reduction in duration of drainage. Further studies are warranted to confirm these results in different and selected types of lymphadenectomy. PMID:23253298

  11. Effect of enamel sealants on tooth bleaching and on the color stability of the result.

    PubMed

    Corcodel, N; Hassel, A J; Sen, S; Saure, D; Rammelsberg, P; Lux, C J; Zingler, S

    2017-04-01

    The purpose of this in vitro study was to evaluate the effect of enamel sealants on bleaching of natural teeth by use of 40 % hydrogen peroxide in a dental surgery. The color stability of the results from bleaching was, furthermore, determined 10 months after the bleaching procedure. In a standardized setting, four sealants (Pro Seal ® , Light Bond™ Sealant, Protecto ® , and Clinpro™ XT Varnish) were applied to and removed from human teeth in accordance with the manufacturer's instructions. Natural teeth served as medium; half of the teeth were sealed and the others served as controls. Hydrogen peroxide gel (40 %; Opalescence Boost; Ultradent Products, South Jordan, UT, USA) was used as bleaching agent. Color measurement was performed with a spectroradiometer (Photoresearch PR670) before the bleaching process (T1) and 24 h (T2) and 10 months (T3) after bleaching. The spectroradiometer results were expressed by use of the Commission Internationale de l'Éclairage (CIE) L*a*b* color notation. The L*, a*, and b* values of the sealed and the unsealed surfaces were not significantly different at any time during the study (p > 0.05), irrespective of the sealant used. Ten months after the bleaching process, mean L*, a*, and b* values were lower than at 1-day post-bleaching; the mean value of ΔE between 1-day post-bleaching and 10 months post-bleaching was 2.46 (±3.1). The results of the study suggest that the effectiveness of professional tooth whitening is not appreciably affected by the application of the four sealants tested.

  12. Long-Standing Motor and Sensory Recovery following Acute Fibrin Sealant Based Neonatal Sciatic Nerve Repair

    PubMed Central

    Ferreira Junior, Rui Seabra

    2016-01-01

    Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA) without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS) at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons. PMID:27446617

  13. Effect of occlusal calculus utilized as a potential "biological sealant" in special needs patients with gastric feeding tubes: a qualitative in vitro contrast to pit and fissure sealant restorations.

    PubMed

    Owens, Barry M; Sharp, Harry K; Fourmy, Emily E; Phebus, Jeffrey G

    2016-01-01

    The aim of this case report and in vitro investigation was to evaluate the marginal microleakage of intact occlusal calculus of primary molars extracted from a special needs patient who received nutrition via a gastric feeding tube. An adolescent with a history of developmental disturbance presented for routine dental care in a hospital facility. Prophylaxis was performed, and 2 mandibular permanent molars were restored. Five primary molars were extracted due to mobility and delayed retention. Heavy deposits of intact calculus were present on the occlusal surfaces of the primary teeth. The extracted teeth were immersed in methylene blue dye solution, invested in acrylic resin, sectioned into blocks, and photographed at 20× and 40× magnification. Previously photographed calculus-free molars with pit and fissure sealants were reviewed and served as contrasting "restorations." The occlusal calculus on the primary teeth extracted from the patient absorbed the dye, while the comparison teeth containing pit and fissure sealants exhibited varying degrees of marginal dye penetration (microleakage). No marginal microleakage was noted in the calculus specimens, indicating that this substrate may serve as a "natural" occlusal surface sealant and that its removal from occlusal surfaces during routine oral prophylaxis may be unnecessary.

  14. Engaging Stakeholders in Patient-Centered Outcomes Research Regarding School-Based Sealant Programs.

    PubMed

    Chi, Donald L; Milgrom, Peter; Gillette, Jane

    2018-02-01

    Purpose: The purpose of this study was to use qualitative methods to describe the key lessons learned during the stakeholder engagement stage of planning a randomized clinical trial comparing outcomes of silver diamine fluoride (SDF) as an alternative to pit-and-fissure sealants in a school-based delivery system. Methods: Eighteen caregivers and community-based stakeholders with involvement in the school-based sealant program Sealants for Smiles from the state of Montana, were recruited for this qualitative study. United States (U.S.) Patient-Centered Outcomes Research Institute (PCORI) methodology standards were used to develop two semi-structured interview guides consisting of 6 questions. One interview guide was used for telephone interviews with caregivers and the second was used for a stakeholder focus group. Content analytic methods were used to analyze the data. Results: All participants believed that a study comparing SDF and sealants was clinically relevant. Non-caregiver stakeholders agreed with the proposed primary outcome of the study (caries prevention) whereas caregivers also emphasized the importance of child-centered outcomes such as minimizing dental anxiety associated with dental care. Stakeholders described potential concerns associated with SDF such as staining and perceptions of safety and discussed ways to address these concerns through community engagement, appropriate framing of the study, proper consent procedures, and ongoing safety monitoring during the trial. Finally, stakeholders suggested dissemination strategies such as direct communication of findings through professional organizations and encouraging insurance plans to incentivize SDF use by reimbursing dental providers. Conclusions: Involving key stakeholders in early planning is essential in developing patient-centered research questions, outcomes measures, study protocols, and dissemination plans for oral health research involving a school-based delivery system. Copyright © 2018

  15. Efficacy of fibrin-sealants in reducing biliary leakage following laparoscopic common bile duct exploration.

    PubMed

    Parra-Membrives, Pablo; Martínez-Baena, Darío; Lorente-Herce, José Manuel; Martín-Balbuena, Ramón

    2018-05-21

    In spite of the acquired experience with laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis management, there is still a risk of biliary leakage of 5% to 15% following choledochotomy closure. We evaluate the usefulness of fibrin-collagen sealants to reduce the incidence of biliary fistula after laparoscopic choledochorrhaphy. We report a retrospective analysis of 96 patients undergoing LCBDE from March 2009 to March 2017, whose closure of the bile duct was completed by antegrade stenting and choledochorraphy or by performing a primary suture. The study population was divided into two groups according to whether they received a collagen-fibrin sealant covering the choledochorrhaphy or not, analyzing the incidence of postoperative biliary fistula in each group. Thirty-nine patients (41%) received a fibrin-collagen sponge while the bile duct closure was not covered in the remaining 57 patients (59%). The incidence of biliary fistula was 7.7% (3 patients) in the first group and 14% (8 patients) in the second group (P=.338). In patients who underwent primary choledochorraphy, the fibrin-collagen sealant reduced the incidence of biliary leakage significantly (4.5% vs. 33%, P=.020), which was a protective factor with an odds ratio of 10.5. Fibrin-collagen sealants may decrease the incidence of biliary fistula in patients who have undergone primary bile duct closure following LCBDE. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Clinical Evaluation of an Adhesive Sealant for Controlling Dental Caries in Naval Personnel: One-Year Results

    DTIC Science & Technology

    1974-08-20

    safeguards were employed in that a voltage monitoring strip chart recorder was employed during sealant placement to ensure continuous delivery of...adequate voltage to the ultraviolet light source (Nuva- Lite)* used for sealant polymerization. Also, a new air compressor** with suitable...ment effect in young Naval personnel. 2. The very low occlusal attack rate for untreated control teeth 3. Dirks, O. B., Houwink, B. and Kwant , G. W

  17. Influence of Delivery Method on Neuroprotection by Bone Marrow Mononuclear Cell Therapy following Ventral Root Reimplantation with Fibrin Sealant

    PubMed Central

    Barbizan, Roberta; Castro, Mateus V.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.

    2014-01-01

    The present work compared the local injection of mononuclear cells to the spinal cord lateral funiculus with the alternative approach of local delivery with fibrin sealant after ventral root avulsion (VRA) and reimplantation. For that, female adult Lewis rats were divided into the following groups: avulsion only, reimplantation with fibrin sealant; root repair with fibrin sealant associated with mononuclear cells; and repair with fibrin sealant and injected mononuclear cells. Cell therapy resulted in greater survival of spinal motoneurons up to four weeks post-surgery, especially when mononuclear cells were added to the fibrin glue. Injection of mononuclear cells to the lateral funiculus yield similar results to the reimplantation alone. Additionally, mononuclear cells added to the fibrin glue increased neurotrophic factor gene transcript levels in the spinal cord ventral horn. Regarding the motor recovery, evaluated by the functional peroneal index, as well as the paw print pressure, cell treated rats performed equally well as compared to reimplanted only animals, and significantly better than the avulsion only subjects. The results herein demonstrate that mononuclear cells therapy is neuroprotective by increasing levels of brain derived neurotrophic factor (BDNF) and glial derived neurotrophic factor (GDNF). Moreover, the use of fibrin sealant mononuclear cells delivery approach gave the best and more long lasting results. PMID:25157845

  18. Measurement of damping of graphite epoxy composite materials and structural joints

    NASA Technical Reports Server (NTRS)

    Crocker, Malcolm J.; Rao, Mohan D.; Raju, P. K.; Yan, Xinche

    1989-01-01

    The damping capacity of graphite epoxy materials and structural joints was evaluated. The damping ratio of different composite specimens and bonded joints were systematically evaluated under normal atmospheric conditions and in a vacuum environment. Free and forced vibration test methods were employed for measuring the damping ratios. The effect of edge support conditions on the damping value of a composite tube specimen was studied by using a series of experiments performed on the specimen with different edge supports. It was found that simulating a free-free boundary conditions by having no constraints at the ends gives the lowest value of the material damping of the composite. The accuracy of the estimation of the damping ratio value was improved by using a curve-fitting technique on the response data obtained through measurement. The effect of outgassing (moisture desorption) on the damping capacity was determined by measuring the damping ratio of the tube specimen in a vacuum environment before and after outgassing had occurred. The effects of high and low temperatures on the damping was also investigated by using a series of experiments on tube and beam specimens. An analytical model to study the vibrations of a bonded lap joint system was formulated. Numerical results were generated for different overlap ratios of the system. These were compared with experimental results. In order to determine the influence of bonded joints on the material damping capacity, experiments were conducted on bonded lap-jointed and double-butt-jointed specimens. These experimental results were compared with simple beam specimens with no joints.

  19. Analysis of anticaries potential of pit and fissures sealants containing amorphous calcium phosphate using synchrotron microtomography.

    PubMed

    Delben, A C B; Cannon, M; Vieira, A E M; Basso, M D; Danelon, M; Santo, M R E; Stock, S R; Xiao, X; De Carlo, F

    2015-01-01

    The aim of this study was to analyze the anticaries potential of pit and fissure sealants containing amorphous calcium phosphate (ACP) by synchrotron microtomography. Bovine enamel blocks (4×4 mm; n=50) were selected through surface hardness (Knoop) analysis. Slabs were obtained through cross-sections taken 1 mm from the border of the enamel. Five indentations, spaced 100 μm apart, were made 300 μm from the border. Ten specimens were prepared for each tested material (Ultraseal XT plus TM, Aegis, Embrace, Vitremer and Experimental Sealant). The materials were randomly attached to the sectioned surfaces of the enamel blocks and fixed with sticky wax. The specimens were submitted to pH cycling. After that, the surface hardness (SH1) was determined, and the blocks were submitted to synchrotron microcomputed tomography analysis to calculate the mineral concentration (ΔgHAp cm(-3)) at different areas of the enamel. The comparison between the SH1 and ΔgHAp cm(-3) showed a correlation for all groups (r=0.840; p<0.001). The fluoride groups presented positive values of ΔgHAp cm(-3), indicating a mineral gain that was observed mainly in the outer part of the enamel. The ACP showed mineral loss in the outer enamel compared with fluoride groups, although it inhibited the demineralization in the deeper areas of enamel. The combination of two remineralizing agents (fluoride and ACP) was highly effective in preventing demineralization.

  20. Caries preventive efficacy of silver diammine fluoride (SDF) and ART sealants in a school-based daily fluoride toothbrushing program in the Philippines.

    PubMed

    Monse, Bella; Heinrich-Weltzien, Roswitha; Mulder, Jan; Holmgren, Christopher; van Palenstein Helderman, Wim H

    2012-11-21

    Occlusal surfaces of erupting and newly erupted permanent molars are particularly susceptible to caries.The objective of the study was to assess and compare the effect of a single application of 38% SDF with ART sealants and no treatment in preventing dentinal (D3) caries lesions on occlusal surfaces of permanent first molars of school children who participated in a daily school-based toothbrushing program with fluoride toothpaste. The prospective community clinical trial in the Philippines was conducted over a period of 18 months and included 704 six- to eight-year-old school children in eight public elementary schools with a daily school-based fluoride toothpaste brushing program. Children were randomly assigned for SDF application or ART sealant treatment. Children from two of the eight schools did not receive SDF or ART sealant treatment and served as controls. SDF or ART sealant treatment was applied on sound occlusal surfaces of permanent first molars. Surfaces that were originally defined as sound at baseline but which changed to dentinal (D3) caries lesions were defined as surfaces with new caries (caries increment). Non-compliance to the daily toothbrushing program in three schools offered the opportunity to analyze the caries preventive effect of SDF and sealants separately in fluoride toothpaste brushing and in non-toothbrushing children. In the brushing group, caries increment in the SDF treatment group was comparable with the non-treatment group but caries increment in the sealant group was lower than in the non-treatment group with a statistically significant lower hazard ratio of 0.12 (0.02-0.61). In the non-brushing group, caries increment in the SDF treatment group and the sealant group was lower than the non-treatment group but the hazard ratio was only statistically significant for the sealant group (HR 0.33; 0.20-0.54). Caries increment was lower in toothbrushing children than in non-toothbrushing children. Hazard ratios reached statistical

  1. Caries preventive efficacy of silver diammine fluoride (SDF) and ART sealants in a school-based daily fluoride toothbrushing program in the Philippines

    PubMed Central

    2012-01-01

    Background Occlusal surfaces of erupting and newly erupted permanent molars are particularly susceptible to caries. The objective of the study was to assess and compare the effect of a single application of 38% SDF with ART sealants and no treatment in preventing dentinal (D3) caries lesions on occlusal surfaces of permanent first molars of school children who participated in a daily school-based toothbrushing program with fluoride toothpaste. Methods The prospective community clinical trial in the Philippines was conducted over a period of 18 months and included 704 six- to eight-year-old school children in eight public elementary schools with a daily school-based fluoride toothpaste brushing program. Children were randomly assigned for SDF application or ART sealant treatment. Children from two of the eight schools did not receive SDF or ART sealant treatment and served as controls. SDF or ART sealant treatment was applied on sound occlusal surfaces of permanent first molars. Surfaces that were originally defined as sound at baseline but which changed to dentinal (D3) caries lesions were defined as surfaces with new caries (caries increment). Non-compliance to the daily toothbrushing program in three schools offered the opportunity to analyze the caries preventive effect of SDF and sealants separately in fluoride toothpaste brushing and in non-toothbrushing children. Results In the brushing group, caries increment in the SDF treatment group was comparable with the non-treatment group but caries increment in the sealant group was lower than in the non-treatment group with a statistically significant lower hazard ratio of 0.12 (0.02-0.61). In the non-brushing group, caries increment in the SDF treatment group and the sealant group was lower than the non-treatment group but the hazard ratio was only statistically significant for the sealant group (HR 0.33; 0.20-0.54). Caries increment was lower in toothbrushing children than in non-toothbrushing children. Hazard

  2. Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures.

    PubMed

    Aguilar, F G; Drubi-Filho, B; Casemiro, L A; Watanabe, M G C; Pires-de-Souza, F C P

    2007-01-01

    This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield) and a photochromatic flowable composite resin (Tetric Flow Chroma) placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment--ten premolars were sealed with each material, isolated (except for the sealed surface) and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab). The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove's total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment--30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab). The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days). New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way ANOVA and Tukey's test P<0.05). Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

  3. Dental Pit and Fissure Sealants: Implications for School Health Personnel.

    ERIC Educational Resources Information Center

    McCormack-Brown, K. R.; And Others

    1989-01-01

    To promote good personal hygiene practices in students, school health personnel must be informed about dental pit and fissure sealants and related programs. Adoption and maintenance of such programs may depend on the success of school health personnel in educating administrators and policymakers. (SM)

  4. Application of a hydrogel ocular sealant to avoid recurrence of epithelial ingrowth after LASIK enhancement.

    PubMed

    Yesilirmak, Nilufer; Diakonis, Vasilios F; Battle, Juan F; Yoo, Sonia H

    2015-04-01

    To report a case of clinically significant epithelial ingrowth after LASIK that was successfully treated with a hydrogel ocular sealant in combination with flap lifting and scraping technique. Case report. A 56-year-old woman underwent LASIK and a LASIK enhancement procedure in 2002 and 2012, respectively. Six months after the enhancement, visually significant epithelial ingrowth developed in both of her eyes. The left eye was treated with flap lifting, scraping, and suturing, and the right eye was treated with a hydrogel ocular sealant in combination with flap lifting and scraping. No recurrence was evident during a 6-month follow-up period and visual acuity improved in both eyes. No adverse effects were noticed. Recurrent epithelial ingrowth may be successfully avoided with the intraoperative use of a hydrogel ocular sealant combined with flap lifting and scraping. This approach could be used as an alternative to LASIK flap suturing. Copyright 2015, SLACK Incorporated.

  5. Thermally resistant polymers for fuel tank sealants

    NASA Technical Reports Server (NTRS)

    Webster, J. A.

    1973-01-01

    Imide-linked perfluoroalkylene ether polymers, that were developed for the high temperature fuel tank sealant application, are discussed. Modifications of polymer structure and properties were realized through use of a new aromatic dianhydride intermediate containing an ether-linked perfluoroalkylene segment. Tests of thermal, oxidative and hydrolytic stability, fuel resistance, and adhesion are discussed along with tensile strength and elongation results. Efforts to effect a low temperature condensation of amic acid prepolymer to form imide links inside are described.

  6. Chylothorax after mediastinal ganglioneuroma resection treated with fibrin sealant patch: a case report

    PubMed Central

    Chiarelli, Marco; Achilli, Pietro; Guttadauro, Angelo; Vertemati, Giuseppe; Terragni, Sabina; De Simone, Matilde

    2017-01-01

    Chylothorax is a severe condition resulting from the accumulation of chyle into the pleural space. We report the treatment of postoperative chylothorax after resection of mediastinal ganglioneuroma in a 17-year-old boy. Since conservative measures were not effective, we performed direct ligation of lymphatic vessels and pleurodesis. At subsequent surgical re-exploration for persisting chylothorax, accurate inspection of pleural cavity revealed residual chyle leakage. Fibrin sealant patches (TachoSil®) were placed over the source of leak with complete resolution of chylous effusion. To our knowledge, this is the first report of postoperative chylothorax successfully treated by the use of a fibrin sealant patch. PMID:29221335

  7. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations.

    PubMed

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5-55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal-Wallis and Bonferroni-Dunn test. The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni-Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition.

  8. In-vivo durability of a fluoride-releasing sealant (OpalSeal) for protection against white-spot lesion formation in orthodontic patients.

    PubMed

    Knösel, Michael; Ellenberger, David; Göldner, Yvonne; Sandoval, Paulo; Wiechmann, Dirk

    2015-04-15

    Sealant application during fixed appliances orthodontic treatment for enamel protection is common, however, reliable data on its durability in vivo are rare. This study aims at assessing the durability of a sealant (OpalSeal, Ultradent) for protection against white-spot lesion formation in orthodontic patients over 26 weeks in vivo, taking into account the provision or absence of an adequate oral hygiene. We tested the null hypothesis of (1) no significant abatement of the sealant after 26 weeks in fixed orthodontic treatment compared to baseline, and (2) no significant influence of the factor of brushing and oral hygiene (as screened by approximal plaque index, API) on the abatement of the sealant. Integrity and abatement of OpalSeal applicated directly following bracketing was assessed in thirty-six consecutive patients (n(teeth) = 796) undergoing orthodontic treatment with fixed appliances (male/female 12/24; mean age/SD 14.4/1.33 Y). Assessment of the fluorescing sealant preservation was by a black-light lamp, using a classification that was concepted in analogy to the ARI index: (3, sealant completely preserved; 2= > 50% preserved; 1 = <50%; 0 = no sealant observable) immediately following application (Baseline, T0), after 2 (T1), 8 (T2), 14 (T3), 20 (T4) and 26 weeks (T5). API was assessed at T0 and T1. Statistical analysis was by non-parametric repeated measures ANOVA (α = 5%, power >80%). At baseline, 43.4% of teeth had a positive API. Oral hygiene deteriorated after bracketing (T1, 53%) significantly. Null hypothesis (1) was rejected, while (2) was accepted: Mean values of both the well brushed and non-brushed anterior teeth undercut the score "1" at T3 (week 14). Despite a slightly better preservation of the sealer before and after T3 in not-sufficiently brushed (API-positive) teeth, this finding was statistically not significant. One single application of OpalSeal is unlikely to last throughout the entire fixed appliance treatment

  9. Evaluation of School-Based Dental Sealant Programs: An Updated Community Guide Systematic Economic Review.

    PubMed

    Griffin, Susan O; Naavaal, Shillpa; Scherrer, Christina; Patel, Mona; Chattopadhyay, Sajal

    2017-03-01

    A recently updated Community Guide systematic review of the effectiveness of school sealant programs (SSPs) still found strong evidence that SSPs reduced dental caries among schoolchildren. This follow-up systematic review updates SSP cost and benefit information from the original 2002 review. Using Community Guide economic review methods, the authors searched the literature from January 2000 to November 20, 2014. The final body of evidence included 14 studies-ten from the current search and four with cost information from the 2002 review. Nine studies had information on SSP costs; six on sealant benefit (averted treatment costs and productivity losses); four on SSP net cost (cost minus benefit); and three on net cost to Medicaid of clinically delivered sealants. The authors imputed productivity losses and discounted costs/outcomes when this information was missing. The analysis, conducted in 2015, reported all values in 2014 U.S. dollars. The median one-time SSP cost per tooth sealed was $11.64. Labor accounted for two thirds of costs, and time to provide sealants was a major cost driver. The median annual economic benefit was $6.29, suggesting that over 4 years the SSP benefit ($23.37 at a 3% discount rate) would exceed costs by $11.73 per sealed tooth. In addition, two of four economic models and all three analyses of Medicaid claims data found that SSP benefit to society exceeded SSP cost. Recent evidence indicates the benefits of SSPs exceed their costs when SSPs target schools attended by a large number of high-risk children. Published by Elsevier Inc.

  10. Abrasion Plus Local Fibrin Sealant Instillation Produces Pleurodesis Similar to Pleurectomy in Rabbits.

    PubMed

    Marchi, Evaldo; de Carvalho, Marcus V H; Ventureli, Tiago R; Fruchi, Andre J; Lazaro, Ariane; do Carmo, Deborah C; Barreto, Thayssa Y A S; Dias, Bruno V B; Acencio, Milena M P; Teixeira, Lisete R; Light, Richard W

    2016-09-01

    Pleurodesis performed either by pleurectomy or pleural abrasion is recommended in the approach to primary spontaneous pneumothorax to avoid recurrence. However, the efficacy of parietal pleural abrasion in producing pleurodesis is questioned. This study aims to determine the efficacy of apical abrasion alone, abrasion plus fibrin sealant application, and pleurectomy in producing pleurodesis in rabbits. Rabbits were subjected to video-assisted thoracic surgery alone (control) or to video-assisted thoracic surgery with apical gauze abrasion, abrasion plus fibrin sealant instillation, or apical pleurectomy. Blood samples were collected preoperatively and 48 h and 28 days postoperatively to measure total leukocytes (white blood cell count), neutrophil counts, and serum interleukin (IL)-8 levels. After 28 days the animals were sacrificed for macroscopic evaluation of the degree of apical pleurodesis and microscopic evaluation of local pleural fibrosis and collagen deposition. White blood cell and neutrophil counts were similar in all groups, whereas the serum IL-8 level peaked at 48 h in all groups and decreased after 28 days, except in the pleurectomy group. After 28 days the abrasion plus fibrin sealant and pleurectomy groups had significantly more pleural adhesions, pleural fibrosis, and collagen deposition than the abrasion alone group, mainly due to thick mature fibers. Abrasion with local fibrin sealant instillation is as effective as pleurectomy in producing pleurodesis in rabbits. Apical pleurectomy elicits a more persistent elevation of serum IL-8 levels than apical abrasion alone or abrasion plus fibrin adhesive instillation. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  11. Effect of three surface sealants on marginal sealing of Class V composite resin restorations.

    PubMed

    Ramos, R P; Chimello, D T; Chinelatti, M A; Dibb, R G; Mondelli, J

    2000-01-01

    This study evaluated in vitro the effectiveness of three different surface sealants (Fortify, Protect-it! and Optiguard) on the marginal sealing of Class V light-activated composite resin restorations (Prodigy). For this purpose, 20 sound noncarious human premolars extracted within a six-month period were selected. Class V cavities with the occlusal margin in enamel and cervical margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with 10 cavities in each group, were restored with composite resin after applying an adhesive system (Optibond FL). After the finishing and polishing procedures, the restorations were covered with a specific surface sealant, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled and immersed in a 50% silver nitrate solution (tracer agent) for eight hours, sectioned longitudinally and analyzed for leakage using an optical microscope in a blind study with three examiners. The marginal microleakage was evaluated at the occlusal and cervical interfaces and compared among the four groups using the Kruskall-Wallis and the Wilcoxon Tests. There was better sealing at the occlusal margin, and in this region, there were no statistically significant differences among the materials (p > 0.05). In the cervical region, Fortify and Protect-it! showed improved results over the Control Group, and Optiguard showed similar results to the Control Group (without sealing).

  12. Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study.

    PubMed

    Eriksen, J R; Bisgaard, T; Assaadzadeh, S; Jorgensen, L N; Rosenberg, J

    2013-08-01

    Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown. We performed a randomized controlled trial including patients with umbilical hernia defects from 1.5 to 5 cm at three Danish hernia centres. We used a 12 cm circular mesh. Participants were randomized to fibrin sealant or titanium tack fixation. Patients were seen in the outpatient clinic at 1 and 12 months follow-up. Forty patients were included of whom 34 were available for intention to treat analysis after 1 year. There were no significant differences in pain, discomfort, fatigue, satisfaction or quality of life between the two groups at the 1-year follow-up. Five patients (26 %) in the fibrin sealant group and one (6 %) in the tack group were diagnosed with a recurrence at the 1-year follow-up (p = 0.182) (overall recurrence rate 17 %). Hernia defects in patients with recurrence were significantly larger than in those without recurrence (median 4.0 vs. 2.8 cm, p = 0.009). Patients with larger hernia defects and fibrin sealant mesh fixation had higher recurrence rates than expected, although the study was not powered for assessment of recurrence. There was no significant difference between groups in any parameters after the 1-year follow-up. The beneficial effects of mesh fixation with fibrin sealant on early outcome warrant further studies on optimization of the surgical technique to prevent recurrence.

  13. A fibrin sealant for perforated and preperforated corneal ulcers.

    PubMed Central

    Lagoutte, F M; Gauthier, L; Comte, P R

    1989-01-01

    Fibrin sealant is used to close perforated or preperforated corneal ulcers. In addition to the usual advantages of cyanoacrylates it is degraded physiologically and provides a good support for corneal healing. Corneal grafting can be avoided when contraindicated or postponed when conditions allow. This technique has been successful in nine eyes of eight patients. Images PMID:2804032

  14. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study.

    PubMed

    Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano

    2012-10-08

    Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  15. Natural Silica Sand/Alumina Ceramic Composites: Promising Candidates for Fuel-Cell Sealants

    NASA Astrophysics Data System (ADS)

    Hidayat, N.; Istiqomah; Widianto, M. Y. H.; Taufiq, A.; Sunaryono; Triwikantoro; Zainuri, M.; Baqiya, M. A.; Aristia, G.; Pratapa, S.

    2017-05-01

    An attempt has been developed to establish the prospect of the useful application of Indonesian natural silica sand, instead of commercially expensive materials, as a future fuel-cell sealant. The sand was initially washed and ball-milled at 150 rpm for 60 minutes and then heated at 1000 °C for the same duration. The resulting powder was then mixed with alumina powder at various amounts and shaped into discs before sintering at 1150 °C and 1250 °C to produce compact ceramics. The diameter shrinkage, porosity, and density of the ceramics were evaluated by Archimedes method. Their crystalline phase composition was quantified by Rietveld refinement analysis on the X-ray diffraction (XRD) data and the phase weight fraction was then used for coefficient of thermal expansion (CTE) evaluation. It was observed that the bulk density increased while the porosity decreased with alumina addition. The XRD data analysis revealed that the prepared silica sand contains a very high purity of quartz-SiO2, i.e. 97.8(18)%. The sintering temperatures of 1150 °C and 1250 °C transformed some quartz-SiO2 to crystobalite-SiO2. All the calcite-CaCO3 exhibited reaction sintering with SiO2 forming wollastonite-CaSiO3. Therefore, the ceramic composites contained SiO2/Al2O3/CaSiO3. Regarding CTE, all of the composites meet the criteria for fuel-cell sealants, in the range of 9-12 ppm/°C.

  16. Evaluation of different types of enamel conditioning before application of a fissure sealant.

    PubMed

    Ciucchi, Philip; Neuhaus, Klaus W; Emerich, Marta; Peutzfeldt, Anne; Lussi, Adrian

    2015-01-01

    The aim of the study was to compare fissure sealant quality after mechanical conditioning of erbium-doped yttrium aluminium garnet (Er:YAG) laser or air abrasion prior to chemical conditioning of phosphoric acid etching or of a self-etch adhesive. Twenty-five permanent molars were initially divided into three groups: control group (n = 5), phosphoric acid etching; test group 1 (n = 10), air abrasion; and test group 2, (n = 10) Er:YAG laser. After mechanical conditioning, the test group teeth were sectioned buccolingually and the occlusal surface of one half tooth (equal to one sample) was acid etched, while a self-etch adhesive was applied on the other half. The fissure system of each sample was sealed, thermo-cycled and immersed in 5% methylene dye for 24 h. Each sample was sectioned buccolingually, and one slice was analysed microscopically. Using specialized software microleakage, unfilled margin, sealant failure and unfilled area proportions were calculated. A nonparametric ANOVA model was applied to compare the Er:YAG treatment with that of air abrasion and the self-etch adhesive with phosphoric acid (α = 0.05). Test groups were compared to the control group using Wilcoxon rank sum tests (α = 0.05). The control group displayed significantly lower microleakage but higher unfilled area proportions than the Er:YAG laser + self-etch adhesive group and displayed significantly higher unfilled margin and unfilled area proportions than the air-abrasion + self-etch adhesive group. There was no statistically significant difference in the quality of sealants applied in fissures treated with either Er:YAG laser or air abrasion prior to phosphoric acid etching, nor in the quality of sealants applied in fissures treated with either self-etch adhesive or phosphoric acid following Er:YAG or air-abrasion treatment.

  17. Usefulness of hemostatic sealants for minimizing ovarian damage during laparoscopic cystectomy for endometriosis.

    PubMed

    Choi, Chahien; Kim, Woo Young; Lee, Dong Hee; Lee, San Hui

    2018-03-01

    We aimed to evaluate the impact of topical hemostatic sealants and bipolar coagulation during laparoscopic ovarian endometriotic cyst resection on ovarian reserve by comparing the rates of decrease in anti-Müllerian hormone (AMH). A randomized prospective data collection was made on women aged 19-45 years who planned to have laparoscopic ovarian cystectomy at one of two institutions (n = 80), Kangbuk Samsung Hospital, Seoul, Korea or National Health Insurance Service Ilsan Hospital, Goyang, Korea, from January 2014 to April 2016. Patients were randomly divided into two groups treated with either a topical hemostatic sealant or bipolar coagulation for hemostasis. The hemostatic group was randomized to the FloSeal or TachoSil subgroups. Preoperative and 3-month postoperative AMH levels were checked and the rates of decrease of AMH were compared. All patients enrolled were treated with dienogest (Visanne) for 6-12 months. None were lost to follow-up at postoperative 3 months, but about one-third of the patients had been lost to follow-up by 6-12 months. AMH was significantly decreased in both groups 3 months postoperatively; however, the rate of decrease in the bipolar coagulation group was greater than that in the hemostatic sealant group, 41.9% (interquartile range [IQR], 22.29-65.24) versus 18.1% (IQR, 10.94-29.90), P = 0.007. Between the two hemostatic subgroups, there was no significant difference in AMH decrease rate, 14.95% (IQR, 11.34-21.21) versus 18.1% (IQR 9.76-40.70), P = 0.204. Hemostatic sealants may be an alternative to bipolar coagulation for preservation of ovarian reserve after laparoscopic ovarian cystectomy for endometriosis. © 2017 Japan Society of Obstetrics and Gynecology.

  18. Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks.

    PubMed

    Park, Bernard J; Snider, John M; Bates, Nathan R; Cassivi, Stephen D; Jett, G Kimble; Sonett, Joshua R; Toloza, Eric M

    2016-12-12

    A biodegradable polymeric sealant has been previously shown to reduce postoperative air leaks after open pulmonary resection. The aim of this study was to evaluate safety and efficacy during minimally invasive pulmonary resection. In a multicenter prospective single-arm trial, 112 patients with a median age of 69 years (range 34-87 years) were treated with sealant for at least one intraoperative air leak after standard methods of repair (sutures, staples or cautery) following minimally invasive pulmonary resection (Video-Assisted Thoracic Surgery (VATS) or Robotic-Assisted). Patients were followed in hospital and 1 month after surgery for procedure-related and device-related complications and presence of air leak. Forty patients had VATS and 72 patients had Robotic-Assisted procedures with the majority (80/112, 71%) undergoing anatomic resection (61 lobectomy, 13 segmentectomy, 6 bilobectomy). There were no device-related adverse events. The overall morbidity rate was 41% (46/112), with major complications occurring in 16.1% (18/112). In-hospital mortality and 30-day mortality were 1.9% (2/103). The majority of intraoperative air leaks (107/133, 81%) were sealed after sealant application, and an additional 16% (21/133) were considered reduced. Forty-nine percent of patients (55/112) were free of air leak throughout the entire postoperative study period. Median chest tube duration was 2 days (range 1 - 46 days), and median length of hospitalization was 3 days (range 1 - 20 days). This study demonstrated that use of a biodegradable polymer for closure of intraoperative air leaks as an adjunct to standard methods is safe and effective following minimally invasive pulmonary resection. ClinicalTrials.gov: NCT01867658 . Registered 3 May 2013.

  19. Fibrin Tissue Sealant as an Adjunct to Cleft Palate Repair.

    PubMed

    Wu, Robin; Wilson, Alexander; Travieso, Roberto; Steinbacher, Derek M

    2017-07-01

    Fibrin glue is a common tissue sealant used to promote hemostasis, adhere tissues, and accelerate healing. Cleft palate repair can be technically challenging, creating dead space between tissue planes, and can be prone to complications such as would dehiscence or bleeding. The purpose of this study is to assess the role of fibrin glue as an adjunct to cleft palate repair. The authors hypothesize a beneficial impact on complication rates, including bleeding, dehiscence, and fistula formation, among others. Primary cleft palate repairs using fibrin glue were retrospectively analyzed. Demographic, intraoperative, perioperative, and postoperative data were combed for outcome variables. Complication rates were calculated in percentages and the results were compared to the published literature. Z-test statistics were performed for comparison. A total of 45 patients, 21 females and 24 males, who underwent primary cleft palate repair with fibrin glue between 2011 and 2014, had sufficient data to be reviewed. There were no instances of bleeding, dehiscence, airway obstruction, infection, oronasal fistula, or return to the operating room in any patients. One patient exhibited mild postoperative coughing and secretions that resolved with conservative measures. Another patient displayed postoperative seizure activity due to a pre-existing condition. All complication rates in our fibrin glue series were lower than those reported without the use of fibrin glue. Overall complication rates with fibrin sealant are significantly lower than overall complication rates without. Our data suggest that fibrin sealant is a beneficial adjunct to cleft palate repair. Its application is well-tolerated and the complication profile in our cohort was much less than the reported rates. The results of this preliminary study should be vetted with a prospective analysis involving a control group.

  20. Dystrophic heart failure blocked by membrane sealant poloxamer

    NASA Astrophysics Data System (ADS)

    Yasuda, Soichiro; Townsend, Dewayne; Michele, Daniel E.; Favre, Elizabeth G.; Day, Sharlene M.; Metzger, Joseph M.

    2005-08-01

    Dystrophin deficiency causes Duchenne muscular dystrophy (DMD) in humans, an inherited and progressive disease of striated muscle deterioration that frequently involves pronounced cardiomyopathy. Heart failure is the second leading cause of fatalities in DMD. Progress towards defining the molecular basis of disease in DMD has mostly come from studies on skeletal muscle, with comparatively little attention directed to cardiac muscle. The pathophysiological mechanisms involved in cardiac myocytes may differ significantly from skeletal myofibres; this is underscored by the presence of significant cardiac disease in patients with truncated or reduced levels of dystrophin but without skeletal muscle disease. Here we show that intact, isolated dystrophin-deficient cardiac myocytes have reduced compliance and increased susceptibility to stretch-mediated calcium overload, leading to cell contracture and death, and that application of the membrane sealant poloxamer 188 corrects these defects in vitro. In vivo administration of poloxamer 188 to dystrophic mice instantly improved ventricular geometry and blocked the development of acute cardiac failure during a dobutamine-mediated stress protocol. Once issues relating to optimal dosing and long-term effects of poloxamer 188 in humans have been resolved, chemical-based membrane sealants could represent a new therapeutic approach for preventing or reversing the progression of cardiomyopathy and heart failure in muscular dystrophy.

  1. Geometry and Material Constraint Effects on Creep Crack Growth Behavior in Welded Joints

    NASA Astrophysics Data System (ADS)

    Li, Y.; Wang, G. Z.; Xuan, F. Z.; Tu, S. T.

    2017-02-01

    In this work, the geometry and material constraint effects on creep crack growth (CCG) and behavior in welded joints were investigated. The CCG paths and rates of two kinds of specimen geometry (C(T) and M(T)) with initial cracks located at soft HAZ (heat-affected zone with lower creep strength) and different material mismatches were simulated. The effect of constraint on creep crack initiation (CCI) time was discussed. The results show that there exists interaction between geometry and material constraints in terms of their effects on CCG rate and CCI time of welded joints. Under the condition of low geometry constraint, the effect of material constraint on CCG rate and CCI time becomes more obvious. Higher material constraint can promote CCG due to the formation of higher stress triaxiality around crack tip. Higher geometry constraint can increase CCG rate and reduce CCI time of welded joints. Both geometry and material constraints should be considered in creep life assessment and design for high-temperature welded components.

  2. Efficacy of quilting sutures and fibrin sealant together for prevention of seroma in extended latissimus dorsi flap donor sites.

    PubMed

    Shin, In Soo; Lee, Dong Won; Lew, Dae Hyun

    2012-09-01

    The extended latissimus dorsi flap is important for breast reconstruction. Unfortunately, donor site seroma is the most common complication of extended latissimus dorsi flap for breast reconstruction. Although using fibrin sealant in the donor site reduces the rate of seroma formation, donor site seroma remains a troublesome complication. The purpose of this study was to analyze the effectiveness of the combination of quilting sutures and fibrin sealant in the latissimus dorsi donor site for the prevention of seroma. Forty-six patients who underwent breast reconstruction with extended latissimus flap were enrolled in the study. The patients received either fibrin sealant (group 1, n=25) or a combination of fibrin sealant and quilting sutures (group 2, n=21) in the extended latissimus dorsi donor site. Outcome measures were obtained from the incidence, volume of postoperative seroma, total drainage amount, indwelling period of drainage, and duration of hospital stay. The incidence of seroma was 76% in group 1 and 42.9% in group 2 (P=0.022). We also found significant reductions in seroma volume (P=0.043), total drainage amount (P=0.002), indwelling period of drainage (P=0.01), and frequency of aspiration (P=0.043). The quilting sutures did not affect the rate of drainage, tube reinsertion, or hospital stay. The use of quilting sutures combined with fibrin sealant on the latissimus dorsi flap donor site is helpful for reducing the overall seroma volume, frequency of aspiration, and total drainage amount.

  3. Evaluation of the remineralization potential of amorphous calcium phosphate and fluoride containing pit and fissure sealants using scanning electron microscopy.

    PubMed

    Choudhary, Prashant; Tandon, Shobha; Ganesh, M; Mehra, Anshul

    2012-01-01

    To evaluate the remineralization potential of Amorphous Calcium Phosphate (ACP) and Fluoride containing pit and Fissure Sealants using Scanning Electron Microscopy. Thirty maxillary first premolars were divided into three groups of ten each and were randomly selected for ACP containing (Aegis- Opaque White, Bosworth Co. Ltd.), Fluoride containing (Teethmate F1 Natural Clear, Kuraray Co. Ltd.), resin based (Concise- Opaque White, 3M ESPE Co. Ltd.) pit and fissure sealant applications. The Concise group served as a control. The teeth weresubjected to the pH-cycling regimen for a period of two weeks. After two weeks, the teeth were sectioned bucco-lingually into 4mm sections and were observed under Scanning Electron Microscope at 50X, 250X, 500X, 1000X and 1500X magnifications. The qualitative changes at the tooth surface and sealant interface were examined and presence of white zone at the interface was considered positive for remineralization. Both ACP containing (Aegis) and Fluoride containing (Teethmate F1) group showed white zone at the tooth surface-sealant interface. The resin based group (Concise) showed regular interface between the sealant and the tooth structure, but no clear cut white zone was observed. Both, Aegis and Teethmate F1 have the potential to remineralize. Release of Amorphous Calcium Phosphate molecules in Aegis group and formation of Fluoroapetite in Teethmate F1 group, were probably responsible for the remineralization.

  4. Abrasion resistance of direct and indirect resins as a function of a sealant veneer.

    PubMed

    Ferraz Caneppele, Taciana Marco; Rocha, Daniel Maranha; Màximo Araujo, Maria Amelia; Valera, Màrcia Carneiro; Salazar Marocho, Susana MarIa

    2014-01-01

    Abrasive wear is one of the most common type of wear that not only affect teeth, as also dental restorations. Thus to investigate one of the etiological factors as tooth brushing procedure is clinical relevant in order to select the best material combination that may prevent damage of resin dental restoration's abrasion. This study evaluated the influence of tooth brushing on mass loss and surface roughness of direct Venus (Vs) and indirect Signum (Sg) resin composites, with and without a surface sealant, Fortify (F). Twenty-four specimens were prepared with each resin composite, using their proprietary curing units, according to manufacturer's instructions. All the specimens were polished and ultrasonically cleaned in distilled water for 5 minutes. Half of the specimens of each resin (n = 12) were covered with F (Vs F and Sg F ), except for the control (C) specimens (Vs C and Sg C ), which were not sealed. Mass loss (ML) as well as surface roughness (Ra ) was measured for all the specimens. Then, the specimens were subjected to toothbrush-dentifrice abrasion, using a testing machine for 67.000 brushing strokes, in an abrasive slurry. After brushing simulation, the specimens were removed from the holder, rinsed thoroughly and blot dried with soft absorbent paper. The abrasion of the material was quantitatively determined with final measurements of ML and surface roughness, using the method described above. ML data were analyzed by two-way analysis of variance (ANOVA) and the analysis indicated that resin composites were not statistically different; however, the specimens sealed with F showed higher ML. Ra mean values of the groups Vs F and Sg F significantly increased. Tooth brushing affects mainly the roughness of the direct and indirect resin composites veneered with a sealant.

  5. Product evaluation : Dow Corning 888

    DOT National Transportation Integrated Search

    1986-07-10

    This report contains a product evaluation of Dow Corning 888 joint sealant. Dow Corning 888 is a one-part silicone material that cures to a low modulus silicone rubber upon exposure to atmospheric moisture. Its uses include transverse and longitudina...

  6. Hemostatic efficacy of EVARREST™, Fibrin Sealant Patch vs. TachoSil® in a heparinized swine spleen incision model.

    PubMed

    Matonick, John P; Hammond, Jeffrey

    2014-12-01

    First-generation single-component hemostats such as oxidized regenerated cellulose (ORC), fibrin, collagen, and gelatin have evolved into second and third generations of combination hemostats. This study compares two FDA approved products, EVARREST™, Fibrin Sealant Patch, a hemostat comprised of a matrix of nonwoven polyglactin 910 embedded in ORC coated with human fibrinogen and thrombin to TachoSil® medicated sponge, an equine collagen pad coated with human fibrinogen and thrombin. Swine were anticoagulated with heparin to 3X their baseline activated clotting time and a 15 mm long × 3 mm deep incision was made to create a consistent moderate bleeding pattern. Test material was then applied to the wound site and compressed manually for 3 min with just enough pressure to prevent continued bleeding. Hemostatic effectiveness was evaluated at 3 min and 10 min. At 3 min, the hemostasis success rate was 86% in the EVARREST™ group and 0% in the TachoSil® group, p < .0001. The overall success rate at 10 min was 100% with EVARREST™ and 4% with TachoSil®, p < .0001. Adhesive failure, in which the test material did not stick to the tissue, occurred in 96% of TachoSil® sites. In contrast, 100% of the EVARREST™ applications adhered to the test site. EVARREST™, Fibrin Sealant Patch demonstrated greater wound adhesion and more effective hemostasis than TachoSil®. Adhesive failure was the primary failure mode for TachoSil® in this model.

  7. Chemically bonded phosphate ceramic sealant formulations for oil field applications

    DOEpatents

    Wagh, Arun S [Naperville, IL; Jeong, Seung-Young [Taejon, KR; McDaniel, Richard [Crest Hill, IL

    2008-10-21

    A sealant for an oil or geothermal well capable of setting within about 3 to about 6 hours at temperatures less than about 250.degree. F. for shallow wells less than about 10,000 feet and deep wells greater than about 10,000 feet having MgO present in the range of from about 9.9 to about 14.5%, KH.sub.2PO.sub.4 present in the range of from about 29.7 to about 27.2%, class C fly ash present in the range of from about 19.8 to about 36.3%, class F fly ash present in the range of from about 19.8 to about 0%, boric acid or borax present in the range of from about 0.39 to about 1.45%, and water present in the range of from about 20.3 to about 21.86% by weight of the sealant.A method of sealing wells is disclosed as are compositions for very high temperature wells is disclosed as is a composition for treating oil field wastes.

  8. Analysis of singular interface stresses in dissimilar material joints for plasma facing components

    NASA Astrophysics Data System (ADS)

    You, J. H.; Bolt, H.

    2001-10-01

    Duplex joint structures are typical material combinations for the actively cooled plasma facing components of fusion devices. The structural integrity under the incident heat loads from the plasma is one of the most crucial issues in the technology of these components. The most critical domain in a duplex joint component is the free surface edge of the bond interface between heterogeneous materials. This is due to the fact that the thermal stress usually shows a singular intensification in this region. If the plasma facing armour tile consists of a brittle material, the existence of the stress singularity can be a direct cause of failure. The present work introduces a comprehensive analytical tool to estimate the impact of the stress singularity for duplex PFC design and quantifies the relative stress intensification in various materials joints by use of a model formulated by Munz and Yang. Several candidate material combinations of plasma facing armour and metallic heat sink are analysed and the results are compared with each other.

  9. Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children

    PubMed Central

    Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew

    2015-01-01

    Objective To compare three variants of a culturally-relevant and theoretically-based message to determine the most influential risk framing approach for improving intention to place dental sealants for preschool children. Design and Sample A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. Measurements We compared participant's scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. Results The mean difference in participant's stage-of-change scores (x = 1.17, n = 89, sd = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t(88) = 5.81, p < .0001, 95% CI [0.77 – 1.57]. Self-efficacy was the only construct for which we detected a statistically significant difference as a function of frame assignment. Overall, the mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Conclusions Community advisory board members determined to use the mix-framed approach in an oral-health social marketing campaign with a rural, American Indian audience. PMID:26032902

  10. Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children.

    PubMed

    Larsson, Laura S; Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew

    2015-01-01

    To compare three variants of a culturally relevant and theoretically based message to determine the most influential risk-framing approach for improving intention to place dental sealants for preschool children. A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. We compared participants' scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. The mean difference in participants' stage-of-change scores (x = 1.17, n = 89, SD = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t88  = 5.81, p < .0001, 95% CI [0.77-1.57]. Self-efficacy was the only construct for which we detected a statistically significant difference as a function of frame assignment. Overall, the mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Community advisory board members determined to use the mix-framed approach in an oral health social marketing campaign with a rural, American Indian audience. © 2015 Wiley Periodicals, Inc.

  11. Knowledge, value, opinion and practice about usage of pit and fissure sealant among dental professionals in Chennai, Tamil Nadu, India.

    PubMed

    Nagappan, N; Dhamodhar, M Dinesh; Nithin, M G; Kumar, E Senthil

    2015-12-01

    A study was aimed to assess the knowledge, value, opinion, and practice regarding the use of dental sealants among private dental practitioners in Chennai, Tamil Nadu, India. A self-administrated questionnaire were distributed to 192 private dental practitioners in Chennai, Tamil Nadu, India by using simple random sampling. A convenience sampling technique was employed. The questionnaire consisted of 28 items, which included information about knowledge, value, opinion, and practice regarding dental sealants. The questionnaire was obtained from the study by San Martin et al. 2013 and Kailash Asawa et al. 2014. Frequency distribution was tabulated. For frequency distribution strongly, strongly agree, and agree were combined as "agree" and strongly disagree and disagree were combined as "disagree." There were no changes in "neutral." Among the 196 study subjects 56.2% were males and 43.8% were females with their clinical experience of 52.1% for <5 years, 35.4% for 5-10 years, and 13.5% for >15 years. The mean scores for knowledge, value, opinion, and practice were 41.8 ± 3.7, 18.7 ± 2.8, 18.1 ± 1.4, and 12.9 ± 2.3, respectively. The results suggest that dental practitioners had satisfactory knowledge about pit and fissure sealant and had neutral attitudes about sealants being effective. Dental practitioners adequately used the pit and fissure sealants but they did not follow the standardized procedures and specific guidelines.

  12. Fibrin sealants or cell saver eliminate the need for autologous blood donation in anemic patients undergoing primary total knee arthroplasty.

    PubMed

    Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich

    2014-01-01

    Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.

  13. INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS

    EPA Science Inventory

    The paper gives results of an investigation of the potential antimicrobial efficacy of sealants used in heating, ventilation and air-conditioning systems. Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fu...

  14. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    PubMed

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  15. An analysis of pipe flange connections using epoxy adhesives/anaerobic sealant instead of gaskets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawa, T.; Sasaki, R.; Yoneno, M.

    1995-11-01

    This paper deals with the strength and the sealing performance of pipe flange connections combining the bonding force of adhesives with the clamping force of bolts. The epoxy adhesives or anaerobic sealants are bonded at the interface partially instead of gaskets in pipe flange connections. The stress distribution in the epoxy adhesives (anaerobic sealant), which governs the sealing performance, and the variations in axial bolt force are analyzed, using an axisymmetrical theory of elasticity, when an internal pressure is applied to a connection in which two pipe flanges are clamped together buy bolts and nuts with an initial clamping forcemore » after being joined by epoxy adhesives or anaerobic sealant. In addition, a method for estimating the strength of the combination connection is demonstrated. Experiments are performed and the analytical results are consistent with the experimental results concerning the variation in axial bolt force and the strength of combination connections. It can be seen that the strength of connections increases with a decrease in the bolt pitch circle diameter. Furthermore, it is seen that the sealing performance of such combination connections in which the interface is bonded partially is improved over that of pipe flange connections with metallic gaskets.« less

  16. Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant.

    PubMed

    Avalos-González, Jorge; Portilla-deBuen, Eliseo; Leal-Cortés, Caridad Aurea; Orozco-Mosqueda, Abel; Estrada-Aguilar, María del Carmen; Velázquez-Ramírez, Gabriela Abigail; Ambriz-González, Gabriela; Fuentes-Orozco, Clotilde; Guzmán-Gurrola, Aldo Emmerson; González-Ojeda, Alejandro

    2010-06-14

    To assess whether the use of fibrin sealant shortens the closure time of postoperative enterocutaneous fistulas (ECFs). The prospective case-control study included 70 patients with postoperative ECFs with an output of < 500 mL/d, a fistulous tract of > 2 cm and without any local complication. They were divided into study (n = 23) and control groups (n = 47). Esophageal, gastric and colocutaneous fistulas were monitored under endoscopic visualization, which also allowed fibrin glue application directly through the external hole. Outcome variables included closure time, time to resume oral feeding and morbidity related to nutritional support. There were no differences in mean age, fistula output, and follow-up. Closure-time for all patients of the study group was 12.5 +/- 14.2 d and 32.5 +/- 17.9 d for the control group (P < 0.001), and morbidity related to nutritional support was 8.6% and 42.5%, respectively (P < 0.01). In patients with colonic fistulas, complete closure occurred 23.5 +/- 19.5 d after the first application of fibrin glue, and spontaneous closure was observed after 36.2 +/- 22.8 d in the control group (P = 0.36). Recurrences were observed in 2 patients because of residual disease. One patient of each group died during follow-up as a consequence of septic complications related to parenteral nutrition. Closure time was significantly reduced with the use of fibrin sealant, and oral feeding was resumed faster. We suggest the use of fibrin sealant for the management of stable enterocutaneous fistulas.

  17. Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant

    PubMed Central

    Avalos-González, Jorge; Portilla-deBuen, Eliseo; Leal-Cortés, Caridad Aurea; Orozco-Mosqueda, Abel; del Carmen Estrada-Aguilar, María; Velázquez-Ramírez, Gabriela Abigail; Ambriz-González, Gabriela; Fuentes-Orozco, Clotilde; Guzmán-Gurrola, Aldo Emmerson; González-Ojeda, Alejandro

    2010-01-01

    AIM: To assess whether the use of fibrin sealant shortens the closure time of postoperative enterocutaneous fistulas (ECFs). METHODS: The prospective case-control study included 70 patients with postoperative ECFs with an output of < 500 mL/d, a fistulous tract of > 2 cm and without any local complication. They were divided into study (n = 23) and control groups (n = 47). Esophageal, gastric and colocutaneous fistulas were monitored under endoscopic visualization, which also allowed fibrin glue application directly through the external hole. Outcome variables included closure time, time to resume oral feeding and morbidity related to nutritional support. RESULTS: There were no differences in mean age, fistula output, and follow-up. Closure-time for all patients of the study group was 12.5 ± 14.2 d and 32.5 ± 17.9 d for the control group (P < 0.001), and morbidity related to nutritional support was 8.6% and 42.5%, respectively (P < 0.01). In patients with colonic fistulas, complete closure occurred 23.5 ± 19.5 d after the first application of fibrin glue, and spontaneous closure was observed after 36.2 ± 22.8 d in the control group (P = 0.36). Recurrences were observed in 2 patients because of residual disease. One patient of each group died during follow-up as a consequence of septic complications related to parenteral nutrition. CONCLUSION: Closure time was significantly reduced with the use of fibrin sealant, and oral feeding was resumed faster. We suggest the use of fibrin sealant for the management of stable enterocutaneous fistulas. PMID:20533600

  18. Durability of sealants exposed to outdoor weathering and hot compression cycles

    Treesearch

    Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt; Christopher C. White; Donald L. Hunston

    2011-01-01

    Sealants play an important role in weatherproofing structures by filling gaps and preventing air and water intrusion. When incorrectly selected or improperly applied, they may fail quickly, compromising durability of the structure. To ensure reliability and prevent the need for costly repairs to structures, it is necessary to measure durability and predict life...

  19. Characterization of low temperature creep properties of crack sealants using bending beam rehometry.

    DOT National Transportation Integrated Search

    2009-11-01

    Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper installation, crack sealants can extend : pavement service life by three to five years. However, current specifications for the selection of crack sea...

  20. Characterization of low temperature mechanical properties of crack sealants utilizing direct tension test.

    DOT National Transportation Integrated Search

    2008-11-01

    Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper : installation, crack sealants can extend pavement service life by three to five years. However, current : specifications for the selection of crack s...

  1. Predicting Young’s Modulus of Glass/Ceramic Sealant for Solid Oxide Fuel Cell Considering the Combined Effects of Aging, Micro-Voids and Self-Healing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wenning N.; Sun, Xin; Khaleel, Mohammad A.

    We study the temperature dependent Young’s modulus for the glass/ceramic seal material used in Solid Oxide Fuel Cells (SOFCs). With longer heat treatment or aging time during operation, further devitrification may reduce the residual glass content in the seal material while boosting the ceramic crystalline content. In the meantime, micro-voids induced by the cooling process from the high operating temperature to room temperature can potentially degrade the mechanical properties of the glass/ceramic sealant. Upon reheating to the SOFC operating temperature, possible self-healing phenomenon may occur in the glass/ceramic sealant which can potentially restore some of its mechanical properties. A phenomenologicalmore » model is developed to model the temperature dependent Young’s modulus of glass/ceramic seal considering the combined effects of aging, micro-voids, and possible self-healing. An aging-time-dependent crystalline content model is first developed to describe the increase of the crystalline content due to the continuing devitrification under high operating temperature. A continuum damage mechanics (CDM) model is then adapted to model the effects of both cooling induced micro-voids and reheating induced self-healing. This model is applied to model the glass-ceramic G18, a candidate SOFC seal material previously developed at PNNL. Experimentally determined temperature dependent Young’s modulus is used to validate the model predictions« less

  2. Use of a vessel sealant device for cystic duct ligation in the dog.

    PubMed

    Marvel, Sarah; Monnet, Eric

    2014-11-01

    To compare a vessel sealant device to hemostatic clips for cystic duct ligation in a canine cadaveric model. Experimental. Hepatobiliary systems were collected from normal dogs. A microtip pressure transducer was inserted into the common bile duct and a 20-24 g intravenous catheter was placed in a hepatic duct. The cystic duct was ligated with 1 of 3 techniques: vessel sealant device (VSD), 10 mm medium Endoclips™, or 10 mm large Endoclips™ with 6 specimens in each group. Methylene blue was infused until failure, which was recorded as seal/clip failure or retrograde movement of methylene blue into the liver. Mean failure pressure of the medium endoclip group was significantly lower than the large endoclip group (P = .014). There was no difference between the failure pressure of the VSD group and the medium and large endoclip groups (P = .097, P = .34, respectively). Failure by leakage at the cut surface of the cystic duct occurred in 2 specimens in the medium endoclip group while all others failed by retrograde flow of the methylene blue through the hepatic ducts. The vessel sealant device appears comparable to large endoclips for closure of the cystic duct in an acute cadaveric model, while medium endoclips may not fully compress or span the diameter of a cystic duct in large breed dogs and leak at lower pressures. © Copyright 2014 by The American College of Veterinary Surgeons.

  3. Combination of heterologous fibrin sealant and bioengineered human embryonic stem cells to improve regeneration following autogenous sciatic nerve grafting repair.

    PubMed

    Mozafari, Roghayeh; Kyrylenko, Sergiy; Castro, Mateus Vidigal; Ferreira, Rui Seabra; Barraviera, Benedito; Oliveira, Alexandre Leite Rodrigues

    2018-01-01

    Peripheral nerve injury is a worldwide clinical problem, and the preferred surgical method for treating it is the end-to-end neurorrhaphy. When it is not possible due to a large nerve gap, autologous nerve grafting is used. However, these surgical techniques result in nerve regeneration at highly variable degrees. It is thus very important to seek complementary techniques to improve motor and sensory recovery. One promising approach could be cell therapy. Transplantation therapy with human embryonic stem cells (hESCs) is appealing because these cells are pluripotent and can differentiate into specialized cell types and have self-renewal ability. Therefore, the main objective of this study was to find conditions under which functional recovery is improved after sciatic nerve neurorrhaphy. We assumed that hESC, either alone or in combination with heterologous fibrin sealant scaffold, could be used to support regeneration in a mouse model of sciatic nerve injury and repair via autografting with end-to-end neurorrhaphy. Five millimeters of the sciatic nerve of C57BL/6 J mice were transected off and rotated 180 degrees to simulate an injury, and then stumps were sutured. Next, we applied heterologous fibrin sealant and/or human embryonic stem cells genetically altered to overexpress fibroblast growth factor 2 (FGF2) at the site of the injury. The study was designed to include six experimental groups comprising neurorrhaphy (N), neurorrhaphy + heterologous fibrin sealant (N + F), neurorrhaphy + heterologous fibrin sealant + doxycycline (N + F + D), neurorrhaphy + heterologous fibrin sealant + wild-type hESC (N + F + W), neurorrhaphy + heterologous fibrin sealant + hESC off (N + F + T), and neurorrhaphy + heterologous fibrin sealant + hESC on via doxycycline (N + F + D + T). We evaluated the recovery rate using Catwalk and von Frey functional recovery tests, as well as immunohistochemistry analysis. The experiments indicated that

  4. Fibrin sealant for closure of mucosal penetration at the cardia during peroral endoscopic myotomy: A retrospective study at a single center

    PubMed Central

    Zhang, Wen-Gang; Linghu, En-Qiang; Li, Hui-Kai

    2017-01-01

    AIM To assess the efficacy and safety of fibrin sealant for closure of mucosal penetration at the cardia during peroral endoscopic myotomy (POEM). METHODS Twenty-four patients who underwent POEM and experienced mucosal injury of the cardia during the procedure were retrospectively identified. Of the 24 patients, 21 had mucosal penetration and 3 had only slight mucosal damage without penetration. The 21 patients with mucosal penetration received fibrin sealant for closure at the site of penetration. Penetration-related characteristics, treatment, and recovery were reviewed for all 21 patients to assess the efficacy and safety of fibrin sealant for closure of mucosal penetration at the cardia. Clinical data, including general characteristics, procedure-related parameters, Eckardt scores, lower esophageal sphincter pressures (LESP), and esophagogastroduodenoscopy (EGD) results, were analyzed to determine their influence on treatment success after mucosal penetration during POEM. RESULTS All 21 patients had a solitary mucosal penetration in the cardia (12 in esophageal region of the cardia, 9 in the stomach region of the cardia, and 1 in both the esophageal and stomach regions). Twelve had a hole-like penetration and 9 had a linear penetration. For those with a hole-like penetration, the mean size was 0.14 cm2 (0.02-0.32 cm2). For those with a linear penetration, the median size was 0.37 cm (0.10-1.00 cm). Closure of the mucosal penetration using fibrin sealant was performed successfully in all 21 patients (two patients required 5 mL fibrin sealant, and the remaining 19 patients required 2.5 mL). Two patients had a nasogastric tube placed for five days after POEM; the remaining 19 patients were kept fasting for 3 d. All 21 patients were discharged after a median of 5 d (range: 5-7 d) postoperatively. During a median 42 mo (range: 9-62 mo) follow-up, all 21 patients with a mucosal penetration successfully healed without the occurrence of infection, ulcer, or esophagitis

  5. Nano-material aspects of shock absorption in bone joints.

    PubMed

    Tributsch, H; Copf, F; Copf, P; Hindenlang, U; Niethard, F U; Schneider, R

    2010-01-01

    This theoretical study is based on a nano-technological evaluation of the effect of pressure on the composite bone fine structure. It turned out, that the well known macroscopic mechano-elastic performance of bones in combination with muscles and tendons is just one functional aspect which is critically supported by additional micro- and nano- shock damping technology aimed at minimising local bone material damage within the joints and supporting spongy bone material. The identified mechanisms comprise essentially three phenomena localised within the three-dimensional spongy structure with channels and so called perforated flexible tensulae membranes of different dimensions intersecting and linking them. Kinetic energy of a mechanical shock may be dissipated within the solid-liquid composite bone structure into heat via the generation of quasi-chaotic hydromechanic micro-turbulence. It may generate electro-kinetic energy in terms of electric currents and potentials. And the resulting specific structural and surface electrochemical changes may induce the compressible intra-osseal liquid to build up pressure dependent free chemical energy. Innovative bone joint prostheses will have to consider and to be adapted to the nano-material aspects of shock absorption in the operated bones.

  6. Nano-Material Aspects of Shock Absorption in Bone Joints

    PubMed Central

    Tributsch, H; Copf, F; Copf, p; Hindenlang, U; Niethard, F.U; Schneider, R

    2010-01-01

    This theoretical study is based on a nano-technological evaluation of the effect of pressure on the composite bone fine structure. It turned out, that the well known macroscopic mechano-elastic performance of bones in combination with muscles and tendons is just one functional aspect which is critically supported by additional micro- and nano- shock damping technology aimed at minimising local bone material damage within the joints and supporting spongy bone material. The identified mechanisms comprise essentially three phenomena localised within the three–dimensional spongy structure with channels and so called perforated flexible tensulae membranes of different dimensions intersecting and linking them. Kinetic energy of a mechanical shock may be dissipated within the solid-liquid composite bone structure into heat via the generation of quasi-chaotic hydromechanic micro-turbulence. It may generate electro-kinetic energy in terms of electric currents and potentials. And the resulting specific structural and surface electrochemical changes may induce the compressible intra-osseal liquid to build up pressure dependent free chemical energy. Innovative bone joint prostheses will have to consider and to be adapted to the nano-material aspects of shock absorption in the operated bones. PMID:21625375

  7. A new heterologous fibrin sealant as a scaffold to cartilage repair—Experimental study and preliminary results

    PubMed Central

    de Barros, Caio Nunes; Miluzzi Yamada, Ana Lúcia; Junior, Rui Seabra F; Barraviera, Benedito; Hussni, Carlos Alberto; de Souza, Jaqueline Brandão; Watanabe, Marcos Jun; Rodrigues, Celso Antônio

    2015-01-01

    Autologous fibrin gel is commonly used as a scaffold for filling defects in articular cartilage. This biomaterial can also be used as a sealant to control small hemorrhages and is especially helpful in situations where tissue reparation capacity is limited. In particular, fibrin can act as a scaffold for various cell types because it can accommodate cell migration, differentiation, and proliferation. Despite knowledge of the advantages of this biomaterial and mastery of the techniques required for its application, the durability of several types of sealant at the site of injury remains questionable. Due to the importance of such data for evaluating the quality and efficiency of fibrin gel formulations on its use as a scaffold, this study sought to analyze the heterologous fibrin sealant developed from the venom of Crotalus durissus terrificus using studies in ovine experimental models. The fibrin gel developed from the venom of this snake was shown to act as a safe, stable, and durable scaffold for up to seven days, without causing adverse side effects. Fibrin gel produced from the venom of the Crotalus durissus terrificus snake possesses many clinical and surgical uses. It presents the potential to be used as a biomaterial to help repair skin lesions or control bleeding, and it may also be used as a scaffold when applied together with various cell types. The intralesional use of the fibrin gel from the venom of this snake may improve surgical and clinical treatments in addition to being inexpensive and adequately consistent, durable, and stable. The new heterologous fibrin sealant is a scaffold candidate to cartilage repair in this study. PMID:26264444

  8. LTPP pavement maintenance materials : SHRP joint reseal experiment, final report.

    DOT National Transportation Integrated Search

    1999-09-01

    The Strategic Highway Research Program (SHRP) H-106 maintenance experiment and the Federal Highway : Administration (FHWA) Long-Term Monitoring (LTM) of Pavement Maintenance Materials Test Sites project studied : the resealing of joints in concrete p...

  9. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    PubMed

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  10. Percutaneous BioOrganic Sealing of Duodenal Fistulas: Case Report and Review of Biological Sealants with Potential Use in Interventional Radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Leeper, William R., E-mail: rob.leeper@jhmi.edu; Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu

    2015-08-15

    Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.

  11. Efficacy of a new sealant to prevent white spot lesions during fixed orthodontic treatment : A 12-month, single-center, randomized controlled clinical trial.

    PubMed

    Hammad, Shaza M; Knösel, Michael

    2016-11-01

    White spot lesions (WSLs) are an undesirable side effect of fixed orthodontic appliance therapy and are reported to occur in 2-96 % of orthodontic patients. In this study, the efficacy of a new sealant to prevent WSLs during fixed orthodontic treatment was compared to a control group that did not receive sealant. For this 2-arm parallel-group randomized trial, 50 subjects aged 12-18 years (mean age 14.57 ± 2.04 years) were recruited from the orthodontics department at Mansoura University, Egypt. Eligibility criteria were no restorations, no active WSLs or caries, and adequate oral hygiene. Subjects were randomized in a 1:1 ratio to one of the two arms prior to undergoing fixed orthodontic treatment, namely a single application of SeLECT Defense™ sealant during the bracketing appointment or no sealant (control arm). Instructions and dentifrices for local home fluoridation regimen were identical in both groups. Oral hygiene was assessed using the Approximal Plaque Index (API) at specified time intervals. Dental photographs were taken for blinded WSLs assessment; inter- and intra-operator error were also calculated. Categorical data were tested using the χ 2 test, and a logistic regression model was adopted to detect associations between decalcification (WSLs), sealant application, and oral hygiene status. Only excellent or good oral hygiene were independent prognostic factors for preventing severe WSLs (p = 0.035). No significant effect on caries incidence was observed for the sealant. In combination with adequate oral hygiene SeLECT Defense™ helps to reduced the frequency of WSLs. However, the sealat showed no significant effect as sole preventive strategy.

  12. PAH concentrations in lake sediment decline following ban on coal-tar-based pavement sealants in Austin, Texas

    USGS Publications Warehouse

    Van Metre, Peter C.; Mahler, Barbara J.

    2013-01-01

    Recent studies have concluded that coal-tar-based pavement sealants are a major source of polycyclic aromatic hydrocarbons (PAHs) in urban settings in large parts of the United States. In 2006, Austin, TX, became the first jurisdiction in the U.S. to ban the use of coal-tar sealants. We evaluated the effect of Austin’s ban by analyzing PAHs in sediment cores and bottom-sediment samples collected in 1998, 2000, 2001, 2012, and 2014 from Lady Bird Lake, the principal receiving water body for Austin urban runoff. The sum concentration of the 16 EPA Priority Pollutant PAHs (∑PAH16) in dated core intervals and surficial bottom-sediment samples collected from sites in the lower lake declined about 44% from 1998–2005 to 2006–2014 (means of 7980 and 4500 μg kg–1, respectively), and by 2012–2014, the decline was about 58% (mean of 3320 μg kg–1). Concentrations of ∑PAH16 in bottom sediment from two of three mid-lake sites decreased by about 71 and 35% from 2001 to 2014. Concentrations at a third site increased by about 14% from 2001 to 2014. The decreases since 2006 reverse a 40-year (1959–1998) upward trend. Despite declines in PAH concentrations, PAH profiles and source-receptor modeling results indicate that coal-tar sealants remain the largest PAH source to the lake, implying that PAH concentrations likely will continue to decline as stocks of previously applied sealant gradually become depleted.

  13. Prevention of internal hernias and pelvic adhesions following laparoscopic left-sided colorectal resection: the role of fibrin sealant.

    PubMed

    Angelini, Pierluigi; Sciuto, Antonio; Cuccurullo, Diego; Pirozzi, Felice; Reggio, Stefano; Corcione, Francesco

    2017-07-01

    Laparoscopy has increasingly become the standard of care for patients who undergo colorectal surgery for both benign and malignant diseases. This growing experience has also resulted in more reports of postoperative complications from the minimally invasive approach to primary colorectal resection. Small bowel obstruction from internal hernias and pre-sacral adhesions is an uncommon but not negligible complication. However, there is little literature specific to this topic with recommendations for different methods to prevent it. We report our original technique of closing the mesenteric defect and covering the pre-sacral fascia by using fibrin sealant to prevent this complication. From January 2005 to December 2014, a total of 1079 patients underwent elective laparoscopic left colorectal resection (left hemicolectomy or anterior rectal resection) in our department. In the first 298 procedures, the mesenteric defect was left open, while in the following 781 procedures, it was closed using fibrin sealant with the aim of preventing postoperative small bowel obstruction. Among the first 298 patients, three (1%) required reoperation for small bowel obstruction due to internal hernia (0.33%) or critical pre-sacral adhesions (0.66%). These complications did not occur in the subsequent series in which all 781 patients were treated with fibrin sealant prophylactic closure of the mesenteric defect. In our experience, fibrin sealant closure of the mesenteric defect has demonstrated to be safe and effective in preventing postoperative small bowel obstruction that remains a complication both in open and in laparoscopic colorectal surgeries.

  14. The effect of internal teat sealant products (Teatseal and Orbeseal) on intramammary infection, clinical mastitis, and somatic cell counts in lactating dairy cows: a meta-analysis.

    PubMed

    Rabiee, A R; Lean, I J

    2013-01-01

    The objective of this study was to assess the efficacy of internal teat sealant products containing bismuth subnitrate (Teatseal and Orbeseal; Pfizer Animal Health, West Ryde, Australia) when used alone, or in the presence of antibiotic dry cow therapy (ADCT), before or at drying off on the incidence of new intramammary infections (IMI), clinical mastitis, and milk somatic cell count (SCC) during lactation. The literature search identified 18 English-language publications on the use of Teatseal in dairy cattle. A total of 12 studies with 17 subtrials or comparisons including 13 positive control subtrials (internal teat sealant and ADCT vs. ADCT) and 4 negative control subtrials (internal teat sealant vs. untreated) examining IMI were included in the analysis. Internal teat sealants, alone or in the presence of ADCT, reduced the risk of acquiring new IMI after calving by 25% [risk ratio (RR)=0.75; 95% confidence interval (CI): 0.67 to 0.83]. Internal teat sealants reduced the risk of IMI by 73% compared with untreated cows (RR=0.27; 95% CI: 0.13 to 0.55). The results of both meta-analyses of IMI, with positive and negative controls, were heterogeneous [I(2) (a statistic that describes the proportion of total variation in study effect estimates that is due to heterogeneity)=65.4 and 92.1%]. No farm or cow factors studied significantly contributed to the heterogeneity of the results. A total of 16 studies (21 subtrials), including 14 positive control subtrials and 7 negative control subtrials, examining clinical mastitis were included in the analysis. Internal teat sealants alone and in the presence of ADCT reduced the risk of clinical mastitis after calving in lactating cows by 29% (RR=0.71; 95% CI: 0.62 to 0.82), and 48% (RR=0.52; 95% CI: 0.37 to 0.75), respectively. The results of the meta-analysis on clinical mastitis with positive controls were homogeneous (I(2)=33.6%), whereas the results of studies with negative controls were heterogeneous (I(2)=60.4%). No farm

  15. Gel sealants for the mitigation of spontaneous heatings in coal mines. Report of investigations/1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miron, Y.

    1995-12-31

    The U.S. Bureau of Mines evaluated three sealant systems for this purpose, bentonite-water mixtures, silicate gel, and guar gum gels. The guar gum-based gel was the only sealant that possessed the desired properties of elasticity, ease of preparation, adaptability to the mine, and a long life. In addition, since the gel consists mostly of water, it could quench or cool nearby heatings. Optimal formulations were determined in laboratory tests, and then tested in the U.S. Bureau of Mines` Safety Research Coal Mine. Two formulations resulted in stable gels that lasted for at least 12 months in the mine. Semi-continuous preparationmore » of gel using an eductor was evaluated and appears feasible.« less

  16. Tissue material properties and computational modelling of the human tibiofemoral joint: a critical review

    PubMed Central

    Akhtar, Riaz; Comerford, Eithne J.; Bates, Karl T.

    2018-01-01

    Understanding how structural and functional alterations of individual tissues impact on whole-joint function is challenging, particularly in humans where direct invasive experimentation is difficult. Finite element (FE) computational models produce quantitative predictions of the mechanical and physiological behaviour of multiple tissues simultaneously, thereby providing a means to study changes that occur through healthy ageing and disease such as osteoarthritis (OA). As a result, significant research investment has been placed in developing such models of the human knee. Previous work has highlighted that model predictions are highly sensitive to the various inputs used to build them, particularly the mathematical definition of material properties of biological tissues. The goal of this systematic review is two-fold. First, we provide a comprehensive summation and evaluation of existing linear elastic material property data for human tibiofemoral joint tissues, tabulating numerical values as a reference resource for future studies. Second, we review efforts to model tibiofemoral joint mechanical behaviour through FE modelling with particular focus on how studies have sourced tissue material properties. The last decade has seen a renaissance in material testing fuelled by development of a variety of new engineering techniques that allow the mechanical behaviour of both soft and hard tissues to be characterised at a spectrum of scales from nano- to bulk tissue level. As a result, there now exists an extremely broad range of published values for human tibiofemoral joint tissues. However, our systematic review highlights gaps and ambiguities that mean quantitative understanding of how tissue material properties alter with age and OA is limited. It is therefore currently challenging to construct FE models of the knee that are truly representative of a specific age or disease-state. Consequently, recent tibiofemoral joint FE models have been highly generic in terms of

  17. Tissue material properties and computational modelling of the human tibiofemoral joint: a critical review.

    PubMed

    Peters, Abby E; Akhtar, Riaz; Comerford, Eithne J; Bates, Karl T

    2018-01-01

    Understanding how structural and functional alterations of individual tissues impact on whole-joint function is challenging, particularly in humans where direct invasive experimentation is difficult. Finite element (FE) computational models produce quantitative predictions of the mechanical and physiological behaviour of multiple tissues simultaneously, thereby providing a means to study changes that occur through healthy ageing and disease such as osteoarthritis (OA). As a result, significant research investment has been placed in developing such models of the human knee. Previous work has highlighted that model predictions are highly sensitive to the various inputs used to build them, particularly the mathematical definition of material properties of biological tissues. The goal of this systematic review is two-fold. First, we provide a comprehensive summation and evaluation of existing linear elastic material property data for human tibiofemoral joint tissues, tabulating numerical values as a reference resource for future studies. Second, we review efforts to model tibiofemoral joint mechanical behaviour through FE modelling with particular focus on how studies have sourced tissue material properties. The last decade has seen a renaissance in material testing fuelled by development of a variety of new engineering techniques that allow the mechanical behaviour of both soft and hard tissues to be characterised at a spectrum of scales from nano- to bulk tissue level. As a result, there now exists an extremely broad range of published values for human tibiofemoral joint tissues. However, our systematic review highlights gaps and ambiguities that mean quantitative understanding of how tissue material properties alter with age and OA is limited. It is therefore currently challenging to construct FE models of the knee that are truly representative of a specific age or disease-state. Consequently, recent tibiofemoral joint FE models have been highly generic in terms of

  18. Effect of dry period length on the effect of an intramammary teat sealant on the risk of mastitis in cattle treated with antibiotics at drying off.

    PubMed

    Laven, R A; Balcomb, C C; Tulley, W T; Lawrence, K E

    2014-07-01

    The aim of this study was to evaluate, under farm conditions, the use of a teat sealant in addition to whole herd dry cow antibiotic therapy on the risk of clinical mastitis in dairy cattle at pasture, and to evaluate the impact of dry period length on that risk and the impact of the teat sealant on that risk. Dairy cows in three herds which used routine whole herd antibiotic therapy were randomly assigned to receive either treatment with an internal teat sealant (n=322) or no additional treatment (n=313) at drying-off between March and May 2010. All clinical mastitis cases during the dry period and to the end of the subsequent lactation were recorded by farm staff; factors affecting risk of clinical mastitis were then analysed using a Cox proportional hazards model. Median duration of the dry period was 112 days with >25% of cows having a dry period >130 days. The incidence risk of mastitis during lactation for cows treated with teat sealant was 9.9 (95% CI=6.9-13.7) cases per 100 cows compared with 17.9 (95% CI=13.8-22.6) cases per 100 cows for cows treated with antibiotic alone. The addition of a teat sealant to dry cow antibiotic therapy decreased the risk of clinical mastitis only in the first 33 days after calving (Hazard risk 0.24 (95% CI=0.12-0.48)). Length of dry period did not significantly affect the risk of clinical mastitis, or the effect of adding teat sealant to dry cow antibiotic therapy on the risk of clinical mastitis. In these herds where, based on the mastitis history, whole herd antibiotic therapy had been recommended, the use of a teat sealant significantly reduced the risk of clinical mastitis. This effect was limited to the first 33 days after calving; subsequently there was no significant effect of treatment. There was no effect of dry period length on risk of clinical mastitis, nor any significant interaction with treatment. Combination therapy with teat sealant and antibiotic was effective under New Zealand conditions in herds using whole

  19. Optimization of La 2O 3-containing diopside based glass-ceramic sealants for fuel cell applications

    NASA Astrophysics Data System (ADS)

    Goel, Ashutosh; Tulyaganov, Dilshat U.; Kharton, Vladislav V.; Yaremchenko, Aleksey A.; Eriksson, Sten; Ferreira, José M. F.

    We report on the optimization of La 2O 3-containing diopside based glass-ceramics (GCs) for sealant applications in solid oxide fuel cells (SOFC). Seven glass compositions were prepared by modifying the parent glass composition, Ca 0.8Ba 0.1MgAl 0.1La 0.1Si 1.9O 6. First five glasses were prepared by the addition of different amounts of B 2O 3 in a systematic manner (i.e. 2, 5, 10, 15, 20 wt.%) to the parent glass composition while the remaining two glasses were derived by substituting SrO for BaO in the glasses containing 2 wt.% and 5 wt.% B 2O 3. Structural and thermal behavior of the glasses was investigated by infrared spectroscopy (FTIR), density measurements, dilatometry and differential thermal analysis (DTA). Liquid-liquid amorphous phase separation was observed in B 2O 3-containing glasses. Sintering and crystallization behavior, microstructure, and properties of the GCs were investigated under different heat treatment conditions (800 and 850 °C; 1-300 h). The GCs with ≥5 wt.% B 2O 3 showed an abnormal thermal expansion behavior above 600 °C. The chemical interaction behavior of the glasses with SOFC electrolyte and metallic interconnects, has been investigated in air atmosphere at SOFC operating temperature. Thermal shock resistance and gas-tightness of GC sealants in contact with 8YSZ was evaluated in air and water. The total electrical resistance of a model cell comprising Crofer 22 APU and 8YSZ plates joined by a GC sealant has been examined by the impedance spectroscopy. Good matching of thermal expansion coefficients (CTE) and strong, but not reactive, adhesion to electrolyte and interconnect, in conjunction with a low level of electrical conductivity, indicate that the investigated GCs are suitable candidates for further experimentation as SOFC sealants.

  20. Application of rape pod sealants to reduce adverse environmental impacts.

    PubMed

    Bauša, Laimis; Steponavičius, Dainius; Jotautienė, Eglė; Kemzūraitė, Aurelija; Zaleckas, Ernestas

    2018-04-01

    Rape (Brassica napus L.) is a major global oilseed crop characterized by its high potential as an alimentary oil and in biodiesel production. The two most popular pod sealants (PS) used to reduce rape pod shattering are products in the pinolene range (di-1-p-menthene) and latex polymer products. Reports on the effective preservation of seed yield by these products are fairly contradictory. With this in mind, an experimental PS (PS4) that contained the active agents acrylic and trisiloxane was developed. Comparative experimental trials of the developed PS4 and three other PS (PS1, PS2 and PS3) containing active agents that are generally used for sealant production were conducted. The studies showed that the static and dynamic surface tension of PS4 was the lowest at the same concentration (2.0 g kg -1 ), consequently demonstrating the lowest spray drift. The chemical substances from PS had not penetrated the rape seeds in any of the PSs. The results indicate that treatment with PS4 exerts a beneficial effect in reducing rape seed yield loss (68-104 kg ha -1 in 2014 and 194-305 kg ha -1 in 2015) compared to other investigated PS. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  1. Welded joints integrity analysis and optimization for fiber laser welding of dissimilar materials

    NASA Astrophysics Data System (ADS)

    Ai, Yuewei; Shao, Xinyu; Jiang, Ping; Li, Peigen; Liu, Yang; Liu, Wei

    2016-11-01

    Dissimilar materials welded joints provide many advantages in power, automotive, chemical, and spacecraft industries. The weld bead integrity which is determined by process parameters plays a significant role in the welding quality during the fiber laser welding (FLW) of dissimilar materials. In this paper, an optimization method by taking the integrity of the weld bead and weld area into consideration is proposed for FLW of dissimilar materials, the low carbon steel and stainless steel. The relationships between the weld bead integrity and process parameters are developed by the genetic algorithm optimized back propagation neural network (GA-BPNN). The particle swarm optimization (PSO) algorithm is taken for optimizing the predicted outputs from GA-BPNN for the objective. Through the optimization process, the desired weld bead with good integrity and minimum weld area are obtained and the corresponding microstructure and microhardness are excellent. The mechanical properties of the optimized joints are greatly improved compared with that of the un-optimized welded joints. Moreover, the effects of significant factors are analyzed based on the statistical approach and the laser power (LP) is identified as the most significant factor on the weld bead integrity and weld area. The results indicate that the proposed method is effective for improving the reliability and stability of welded joints in the practical production.

  2. A comparative study of fissure sealants Helioseal Clear Chroma and Delton FS(+): 3 year results.

    PubMed

    Kargul, B; Tanboga, I; Gulman, N

    2009-12-01

    To evaluate the retention rates of a resin based colour changing fissure sealant (Helioseal Clear Chroma; Ivoclar Vivadent AG Schaan, Liechtenstein) compared with a coloured resin based fluoride fissure sealant (Delton FS(+); Dentsply De Trey GmbH,Konstanz,Germany). The fissure sealants (FS) were placed on all 4 caries-free first permanent molars of 31 children aged 6-9 years, using a half mouth experimental design by a paediatric dentist according to the manufacturers' instructions. A total of 121 FS were placed at baseline. Teeth were evaluated at 3 month intervals for 36 months where a preventive program including topical fluoride application was applied. Retention rates for 36 months showed a differences between Delton FS(+) and Helioseal Clear Chroma that were statistically significant (p<0.05). Delton FS(+) had total retention rate of 30.4% for 36 months compared with Helioseal Clear Chroma at 10.8% for the same evaluation period. Although Delton FS(+) showed significantly better results than Helioseal Clear Chroma for the evaluation periods, there were no statistically significant differences between Delton FS(+) (90.7%) and Helioseal Clear Chroma (80.4%) with respect to caries incidence at 36 months(p>0.05). Delton FS(+) showed a better complete retention rate for occlusal FS at one year. Both FS were aesthetically acceptable and easy to see during application and follow-up periods and gave significant protection from occlusal decay.

  3. Effect of surface sealants on microleakage of Class II restorations after thermocycling and long-term water storage.

    PubMed

    Lima, Adriano Fonseca; Soares, Giulliana Panfiglio; Vasconcellos, Pedro Henrique; Ambrosano, Gláucia Maria; Marchi, Giselle Maria; Lovadino, José Roberto; Aguiar, Flávio Henrique

    2011-06-01

    To evaluate interface degradation leading to marginal microleakeage in Class II restorations that had received an application of surface sealant at the tooth/restoration interface or not. Eighty bovine incisors were used, and the teeth were split obliquely, 10 mm from the amelodentinal proximal junction, and finished with water abrasive papers to obtain a smooth, flat incisal surface. Cavities were made to simulate Class II preparations (8 mm high, 4 mm wide and 1.5 mm deep), and the restorations were performed with a composite resin. Teeth were then randomly allocated into 8 groups according to the surface sealant (none, Fortify, Single Bond 2, or Scothbond MP Plus) and aging process (none or thermocycling and storage for 6 months). Microleakage was then evaluated using a dye penetration method immediately after the restoration or after aging. The samples were triturated and assessed by spectrophotometer. Microleakage was statistically similar in all groups when assessed immediately after the restorative procedure. After aging, teeth sealed with Fortify presented better results than the other groups. Aging causes interface degradation and increased microleakage. Surface sealant can reduce these effects and decrease microleakage in Class II restorations.

  4. Injectible candidate sealants for fetal membrane repair: Bonding and toxicity in vitro

    PubMed Central

    Bilic, Grozdana; Brubaker, Carrie; Messersmith, Phillip B.; Mallik, Ajit S.; Quinn, Thomas M.; Haller, Claudia; Done, Elisa; Gucciardo, Leonardo; Zeisberger, Steffen M.; Zimmermann, Roland; Deprest, Jan; Zisch, Andreas H.

    2010-01-01

    Objective This study was undertaken to test injectible surgical sealants that are biocompatible with fetal membranes, eventually for closure of iatrogenic membrane defects. Study Design Dermabond, Histoacryl, Tissucol fibrin glue, and three types of in situ forming poly(ethylene glycol)-based polymer hydrogels were tested for acute toxicity upon direct contact with fetal membranes for 24h. For determination of elution toxicity, extracts of sealants were incubated on amnion cell cultures for 72h. Bonding and toxicity was assessed through morphological and/or biochemical analysis. Results Extracts of all adhesives were non-toxic for cultured cells. However, only Tissucol and one type of poly(ethylene glycol)-based hydrogel, mussel-mimetic tissue adhesive, showed efficient, non-disruptive, non-toxic bonding to fetal membranes. Mussel-mimetic tissue adhesive applied over membrane defects created with a 3.5 mm trocar accomplished leak-proof closure that withstood membrane stretch in an in vitro model. Conclusion A synthetic hydrogel-type tissue adhesive emerged as potential sealing modality for iatrogenic membrane defects that merits further evaluation in vivo. PMID:20096254

  5. TRICARE; Revision of Nonparticipating Providers Reimbursement Rate; Removal of Cost Share for Dental Sealants; TRICARE Dental Program. Final rule.

    PubMed

    2016-03-07

    This final rule revises the benefit payment provision for nonparticipating providers to more closely mirror industry practices by requiring TDP nonparticipating providers to be reimbursed (minus the appropriate cost-share) at the lesser of billed charges or the network maximum allowable charge for similar services in that same locality (region) or state. This rule also updates the regulatory provisions regarding dental sealants to clearly categorize them as a preventive service and, consequently, eliminate the current 20 percent cost-share applicable to sealants to conform with the language in the regulation to the statute.

  6. Effect of laser and air abrasion pretreatment on the microleakage of a fissure sealant applied with conventional and self etch adhesives.

    PubMed

    Tirali, R E; Celik, C; Arhun, N; Berk, G; Cehreli, S B

    2013-01-01

    The purpose of this study was to investigate the effects of different pretreatment protocols along with different bonding agents on the microleakage of a fissure sealant material. A total of 144 freshly extracted noncarious human third molars were used The teeth were randomly assigned into three groups with respect to the pretreatment protocol employed: A. Air Abrasion B. Er,Cr:YSGG laser C. No pretreatment (Control). In each group specimens were further subjected to one of the following procedures before application of the sealant: 1. %36 Phosphoric acid-etch (AE) (DeTrey Conditioner 36/Denstply, UK) 2.AE+Prime&Bond NT (Dentsply, UK) 3. Clearfil S3 Bond (Kuraray, Japan) 4. Clearfil SE Bond (Kuraray, Japan). All teeth were sealed with the same fissure sealant material (Conseal F/SDI, Australia). Sealed teeth were further subjected to thermocycling, dye penetration test, sectioning and quantitative image analysis. Statistical evaluation of the microleakage data was performed with two way independent ANOVA and multiple comparisons test at p = 0.05. For qualitative evaluation 2 samples from each group were examined under Scanning Electron Microscopy. Microleakage was affected by both the type of pretreatment and the subsequent bonding protocols employed (p < 0.05). Overall, the highest (Mean = 0.36 mm) and lowest (Mean = 0.06 mm) microleakage values were observed in samples with unpretreated enamel sealed by S3+Conseal F and samples with laser pretreated enamel sealed by Acid Etch+Prime&-Bond+Conseal F protocols, respectively (p < 0.05). In the acid-etch group samples pretreated with laser yielded in slightly lower microleakage scores when compared with unpretreated samples and samples pretreated with air abrasion but the statistical significance was not important (p = 0,179). Similarly, when bonding agent is applied following acid-etching procedure, microleakage scores were not affected from pretreatment protocol (p = 0,615) (intact enamel/laser or air-abrasion). For

  7. Effect of Temperature on the Storage Life of Polysulfide Sealants

    DTIC Science & Technology

    1989-01-01

    University of Adelaide, South Australia. After two and a half years of experience in Rubber Technology with the Olympic Tyre and Rubber Company, Melbourne...he joined the rubber section of MRL in November 1970. Since 1975 he has been involved in R & D work in the sealant section as an Experimental Officer...repeatedly passing the mixture through a triple roll mill. One set of the calcium carbonate-solvent series was enclosed in a heat sealed wrapping of

  8. Controlling air leaks using free pericardial fat pads as surgical sealant in pulmonary resection.

    PubMed

    Ikeda, Takeshi; Sasaki, Masato; Yamada, Narihisa; Takamori, Atsushi; Tanabe, Sawaka; Okada, Akitoshi; Sakon, Kayo; Mizunaga, Tae; Koshiji, Takaaki

    2015-04-01

    This study evaluated the feasibility and efficacy of a new operative method for controlling intraoperative air leaks using free pericardial fat pads as a covering sealant in pulmonary resection. To manage air leaks that must be controlled in pulmonary resection at the first water sealing test, collected free pericardial fat was used as a covering sealant and sewn on by the suture closing the lesion. In cases of uncontrolled air leaks at the second sealing test, fibrin glue was used to fill the residual lesion between the fat and visceral pleura. Fifty-one eligible patients were enrolled in this study to evaluate the duration of postoperative air leaks and the condition of the implanted fat on chest computed tomography (CT) 6 months later. The mean duration of postoperative air leaks was 1.05 ± 1.84 days in the 39 cases that received the pericardial fat covering technique only and 2.66 ± 3.42 days in the 12 cases that received the pericardial fat covering technique combined with fibrin glue. Prolonged alveolar air leaks occurred in 1 case and 2 cases, respectively. No cases required conversion to conventional methods, and there were no further adverse events. On follow-up chest CT approximately 62.7% of obvious engrafted fat survived. Using free pericardial fat pads as a sealant to control air leaks in pulmonary resection is safe and has good feasibility and potent efficacy. This new method can be an innovative technique for preventing prolonged air leaks. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Study Materials for Economic Education in the Schools. Reports of Materials Evaluation Committees to the Joint Council on Economic Education.

    ERIC Educational Resources Information Center

    Joint Council on Economic Education, New York, NY.

    The Materials Evaluation Committee of the Joint Council reviewed both print and non-print supplementary student materials for economics in order to make this selected list of those materials thought to be suitable according to: 1) whether the materials are genuinely concerned with economic matters; 2) whether they are analytical in nature; and, 3)…

  10. Wellbore Completion Systems Containment Breach Solution Experiments at a Large Scale Underground Research Laboratory : Sealant placement & scale-up from Lab to Field

    NASA Astrophysics Data System (ADS)

    Goodman, H.

    2017-12-01

    This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244

  11. Advances in dental materials.

    PubMed

    Vaderhobli, Ram M

    2011-07-01

    The use of materials to rehabilitate tooth structures is constantly changing. Over the past decade, newer material processing techniques and technologies have significantly improved the dependability and predictability of dental material for clinicians. The greatest obstacle, however, is in choosing the right combination for continued success. Finding predictable approaches for successful restorative procedures has been the goal of clinical and material scientists. This article provides a broad perspective on the advances made in various classes of dental restorative materials in terms of their functionality with respect to pit and fissure sealants, glass ionomers, and dental composites. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing.

    PubMed

    Gomes-Silva, Jaciara Miranda; Torres, Carolina Paes; Contente, Marta Maria Martins Giamatei; Oliveira, Maria Angélica Hueb de Menezes; Palma-Dibb, Regina Guenka; Borsatto, Maria Cristina

    2008-01-01

    This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (alpha=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (+/-4.29); II-8.57 (+/-3.19); III-7.97 (+/-2.16); IV-12.56 (+/-3.11); V-11.45 (+/-3.77); and VI-7.47 (+/-1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.

  13. Influence of Prosthetic Screw Material on Joint Stability in Passive and Non-Passive Implant-Supported Dentures

    PubMed Central

    Spazzin, Aloísio Oro; Henriques, Guilherme Elias Pessanha; de Arruda Nóbilo, Mauro Antônio; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço; Mesquita, Marcelo Ferraz

    2009-01-01

    Objectives: This study evaluated the influence of prosthetic screw material on joint stability in implantsupported dentures at two levels of fit. Methods: Ten mandibular implant-supported dentures were fabricated. Twenty cast models were fabricated using these dentures. Four groups (n=10) were tested, according to the vertical fit of the dentures [passive and non-passive] and prosthetic screw materials [titanium (Ti) or gold (Au) alloy]. The one-screw test was performed to quantify the vertical misfits using an optic microscope. The loosening torque for the prosthetic screws was measured 24 hours after the tightening torque (10 Ncm) using a digital torque meter. Data were analyzed by two-way ANOVA and Tukey’s test (α=0.05). Results: Overall, dentures with passive fit and Ti screws resulted in significantly higher loosening torque of the prosthetic screws (p<0.05). No significant interaction was found between fit level and screw material (p=0.199). The prosthetic screw material and fit of implant-supported dentures have an influence on screw joint stability. Ti screws presented higher joint stability than Au screws and minimum of misfit should be found clinically to improve the mechanical behavior of the screw joint. PMID:20148135

  14. INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS: JOURNAL ARTICLE

    EPA Science Inventory

    NRMRL-RTP-P- 530a Foarde, K.K., VanOsdell, D.W., and Menetrez*, M.Y. Investigation of the Potential Antimicrobial Efficacy of Sealants Used in HVAC Systems. Published in: Journal of Air and Waste Management Association 51 (8):1219-1226 (2001). 07/06/2000 The paper gives result...

  15. A tribological and biomimetic study of potential bone joint repair materials

    NASA Astrophysics Data System (ADS)

    Ribeiro, Rahul

    This research investigates materials for bone-joint failure repair using tribological and biomimicking approaches. The materials investigated represent three different repairing strategies. Refractory metals with and without treatment are candidates for total joint replacements due to their mechanical strength, high corrosion resistance and biocompatibility. A composite of biodegradable polytrimethylene carbonate, hydroxyl apatite, and nanotubes was investigated for application as a tissue engineering scaffold. Non-biodegradable polymer polyimide combined with various concentrations of nanotubes was investigated as a cartilage replacement material. A series of experimental approaches were used in this research. These include analysis of material surfaces and debris using high-resolution techniques and tribological experiments, as well as evaluation of nanomechanical properties. Specifically, the surface structure and wear mechanisms were investigated using a scanning electron microscope and an atomic force microscope. Debris morphology and structure was investigated using a transmission electron microscope. The debris composition was analyzed using an X-ray diffractometer. Nanoindentation was incorporated to investigate the surface nanomechanical properties. Polytrimythelene carbonate combined with hydroxyapatite and nanotubes exhibited a friction coefficient lower than UHMWPE. The nanoindentation response mimicked cartilage more closely than UHMWPE. A composite formed with PI and nanotubes showed a varying friction coefficient and varying nanoindentation response with variation in nanotube concentration. Low friction coefficients corresponded with low modulus values. A theory was proposed to explain this behavior based on surface interactions between nanotubes and between nanotubes and PI. A model was developed to simulate the modulus as a function of nanotube concentration. The boronized refractory metals exhibited brittleness and cracking. Higher friction

  16. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  17. Tensile Shear Properties of the Friction Stir Lap Welded Joints and Material Flow Mechanism Under Pulsatile Revolutions

    NASA Astrophysics Data System (ADS)

    Hu, Yanying; Liu, Huijie; Du, Shuaishuai

    2018-06-01

    The aim of the present article is to offer insight into the effects of pin profiles on interface defects, tensile shear properties, microstructures, and the material flow of friction stir lap welded joints. The results indicate that, compared to the lap joints welded by the single threaded plane pin, the three-plane threaded pin, and the triangle threaded pin, the lap joint obtained by the conventional conical threaded pin is characterized by the minimum interface defect. The alternate threads and planes on the pin provide periodical stress, leading to pulsatile material flow patterns. Under the effect of pulsatile revolutions, an asymmetrical flow field is formed around the tool. The threads on the pin force the surrounding material to flow downward. The planes cannot only promote the horizontal flow of the material by scraping, but also provide extra space for the material vertical flow. A heuristic model is established to describe the material flow mechanism during friction stir lap welding under the effect of pulsatile revolutions.

  18. EVALUATING THE POTENTIAL EFFICACY OF AN ANTIMICROBIAL-CONTAINING SEALANT ON DUCT LINER AND GALVANIZED STEEL

    EPA Science Inventory

    The article gives results of an evaluation of the potential efficacy of an antimicrobial-containing sealant on fibrous-glass duct liner (FGDL) and galvanized steel (GS) as used in heating, ventilating, and air-conditioning (HVAC) systems. HVAC systems become dirty to various degr...

  19. Presence and leaching of bisphenol a (BPA) from dental materials

    PubMed Central

    Becher, Rune; Wellendorf, Hanne; Sakhi, Amrit Kaur; Samuelsen, Jan Tore; Thomsen, Cathrine; Bølling, Anette Kocbach; Kopperud, Hilde Molvig

    2018-01-01

    Abstract BPA has been reported to leach from some resin based dental restorative materials and materials used for orthodontic treatment. To confirm and update previous findings, especially in light of the new temporary lower threshold value for tolerable daily BPA intake, we have investigated the leaching of BPA from 4 composite filling materials, 3 sealants and 2 orthodontic bonding materials. The materials were either uncured and dissolved in methanol or cured. The cured materials were kept in deionized water for 24 hours or 2 weeks. Samples were subsequently analyzed by ultra-performance liquid chromatography coupled to mass spectrometry (UPLC-MS-MS). The composite filling material Tetric EvoFlow® and the fissure sealant DELTON® showed significantly higher levels of BPA leaching compared to control samples for all test conditions (uncured, 24 h leaching and 2 weeks leaching). There were no significant differences in amount of leached BPA for any of the tested materials after 24 hours compared to 2 weeks. These results show that BPA is still released from some dental materials despite the general concern about potential adverse effects of BPA. However, the amounts of BPA were relatively low and most likely represent a very small contribution to the total BPA exposure. PMID:29868625

  20. Presence and leaching of bisphenol a (BPA) from dental materials.

    PubMed

    Becher, Rune; Wellendorf, Hanne; Sakhi, Amrit Kaur; Samuelsen, Jan Tore; Thomsen, Cathrine; Bølling, Anette Kocbach; Kopperud, Hilde Molvig

    2018-01-01

    BPA has been reported to leach from some resin based dental restorative materials and materials used for orthodontic treatment. To confirm and update previous findings, especially in light of the new temporary lower threshold value for tolerable daily BPA intake, we have investigated the leaching of BPA from 4 composite filling materials, 3 sealants and 2 orthodontic bonding materials. The materials were either uncured and dissolved in methanol or cured. The cured materials were kept in deionized water for 24 hours or 2 weeks. Samples were subsequently analyzed by ultra-performance liquid chromatography coupled to mass spectrometry (UPLC-MS-MS). The composite filling material Tetric EvoFlow ® and the fissure sealant DELTON ® showed significantly higher levels of BPA leaching compared to control samples for all test conditions (uncured, 24 h leaching and 2 weeks leaching). There were no significant differences in amount of leached BPA for any of the tested materials after 24 hours compared to 2 weeks. These results show that BPA is still released from some dental materials despite the general concern about potential adverse effects of BPA. However, the amounts of BPA were relatively low and most likely represent a very small contribution to the total BPA exposure.

  1. Fibrin chain cross-linking, fibrinolysis, and in vivo sealing efficacy of differently structured fibrin sealants.

    PubMed

    Hedrich, Hans Christian; Simunek, Manuela; Reisinger, Sonja; Ferguson, James; Gulle, Heinz; Goppelt, Andreas; Redl, Heinz

    2012-08-01

    In this study, we compared the sealing characteristics and efficacy of a fibrin sealant with reduced plasminogen (FS-rplg) and a fibrin sealant with aprotinin as a fibrinolysis inhibitor (FS-apr). The relevant sealing characteristics including clot structure, fibrin chain cross-linking, and clot lysis were tested in the laboratory. The sealing efficacy was then investigated in a follow-up animal model to determine differences in the in vivo sealing properties. A total of 46 animals were available for the final analysis with 23 animals in each treatment arm. In conclusion, we saw differences in vitro between FS-rplg and FS-apr in ultrastructure and α-chain cross-linking rates as well as in the rate of fibrinolysis. These differences may explain the significantly enhanced sealing efficacy in FS-apr compared to FS-rplg shown in vivo in a rabbit intestinal model. Copyright © 2012 Wiley Periodicals, Inc.

  2. Parents' Attitude towards the Use of Fluorides and Fissure Sealants and its Effect on their Children's Oral Health.

    PubMed

    Blumer, Sigalit; Ratson, Tal; Peretz, Benjamin; Dagon, Nurit

    To characterize the attitudes of Israeli parents towards caries preventive measures. participating parents completed a 21-item questionnaire on their demographics, dental history, attitudes and satisfaction from fluorides and fissure sealants. One hundred parents (average age 41.62±4.9 years, 85 females) participated. Most of the parents (88% of the mothers and 84% of the fathers) had an academic education. Most of the parents (54%) had a favorable attitude towards the use of fluoridated gels, while only 37% of them had a positive opinion regarding fluoridated water. The satisfaction levels were very high regarding fissure sealants, fluoridated mouth rinses and fluoridated gels (78.1%, 73.6% and 72.5% respectively). The satisfaction from fluoridated water was split almost equally (50.8% were 'pleased' and 49.2% 'not pleased'). The main source for parental oral health knowledge was the dentist (83%). Parents' attitude towards caries preventive measures was significantly correlated to their gender, dental experience, level of education and the number of children in the family. positive attitude towards caries preventive measures was found among parents with higher awareness for preventive oral health measures and among bigger families. Mothers were more positive about fissure sealants than fathers. Mothers with up to 12 years of education tended to have a positive opinion regarding water fluoridation.

  3. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test. 2. Carbon adsorber (regenerative) to which puncture sealant application spray booth emissions are ducted a. Maintain the total regeneration mass, volumetric flow, and carbon bed temperature at the operating range established during the performance test.b. Reestablish the carbon bed temperature...

  4. 76 FR 79537 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-22

    ... Division, U.S. Environmental Protection Agency, Region III, 1650 Arch Street, Philadelphia, Pennsylvania...--Adhesives and Sealants under Regulation 1141--Limiting Emissions of Volatile Organic Compounds from Consumer.... The revision is part of Delaware's strategy to achieve and maintain the 8- hour ozone national ambient...

  5. The electrical properties and glass transition of some dental materials after temperature exposure.

    PubMed

    Marcinkowska, Agnieszka; Gauza-Wlodarczyk, Marlena; Kubisz, Leszek; Hedzelek, Wieslaw

    2017-10-17

    The physicochemical properties of dental materials will remain stable only when these materials in question are resistant to the changes in the oral cavity. The oral environment is subject to large temperature variations. The aim of the study was the assessment of electrical properties and glass transition of some dental materials after temperature exposure. Composite materials, compomers, materials for temporary prosthetic replacement and resin-based pit and fissure sealants were used in the study. The method used was electric conductivity of materials under changing temperature. The order of materials presenting the best characteristics for insulators was as follows: materials for temporary prosthetic replacement, resin-based pit and fissure sealants, composites, and compomers. Thanks to comparisons made between graphs during I and II heating run, the method could be used to observe changes in the heated material and determine whether the changes observed are reversible or permanent. The graphs also provided temperature values which contain information on glass transition during heating. In the oral cavity the effect of the constant temperature stimulus influences maturity of dental materials and improves their properties. But high temperatures over glass transition temperature can cause irreversible deformation and changes of the materials properties, even in a short time.

  6. Expert system for adhesive selection of composite material joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, R.B.; Vanderveldt, H.H.

    The development of composite joining is still in its infancy and much is yet to be learned. Consequently, this field is developing rapidly and new advances occur with great regularity. The need for up-to-date information and expertise in engineering and planning of composite materials, especially in critical applications, is acute. The American Joining Institute`s (AJI) development of JOINEXCELL (an off-line intelligent planner for joining composite materials) is an intelligent engineering/planning software system that incorporates the knowledge of several experts which can be expanded as these developments occur. Phase I effort of JOINEXCELL produced an expert system for adhesive selection, JOINADSELECT,more » for composite material joints. The expert system successfully selects from over 26 different adhesive families for 44 separate material types and hundreds of application situations. Through a series of design questions the expert system selects the proper adhesive for each particular design. Performing this {open_quotes}off-line{close_quotes} engineering planning by computer allows the decision to be made with full knowledge of the latest information about materials and joining procedures. JOINADSELECT can greatly expedite the joining design process, thus yielding cost savings.« less

  7. Behavior of Aging, Micro-Void, and Self-Healing of Glass/Ceramic Materials and Its Effect on Mechanical Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wenning N.; Sun, Xin; Khaleel, Mohammad A.

    This chapter first describes tests to investigate the temporal evolution of the volume fraction of ceramic phases, the evolution of micro-damage, and the self-healing behavior of the glass ceramic sealant used in SOFCs, then a phenomenological model based on mechanical analogs is developed to describe the temperature dependent Young’s modulus of glass ceramic seal materials. It was found that after the initial sintering process, further crystallization of the glass ceramic sealant does not stop, but slows down and reduces the residual glass content while boosting the ceramic crystalline content. Under the long-term operating environment, distinct fibrous and needle-like crystals inmore » the amorphous phase disappeared, and smeared/diffused phase boundaries between the glass phase and ceramic phase were observed. Meanwhile, the micro-damage was induced by the cooling-down process from the operating temperature to the room temperature, which can potentially degrade the mechanical properties of the glass/ceramic sealant. The glass/ceramic sealant self-healed upon reheating to the SOFC operating temperature, which can restore the mechanical performance of the glass/ceramic sealant. The phenomenological model developed here includes the effects of continuing aging and devitrification on the ceramic phase volume fraction and the resulted mechanical properties of glass ceramic seal material are considered. The effects of micro-voids and self-healing are also considered using a continuum damage mechanics (CDM) model. The formulation is for glass/ceramic seal in general, and it can be further developed to account for effects of various processing parameters. This model was applied to G18, and the temperature-dependent experimental measurements were used to calibrate the modeling parameters and to validate the model prediction.« less

  8. Ceramic joints

    DOEpatents

    Miller, Bradley J.; Patten, Jr., Donald O.

    1991-01-01

    Butt joints between materials having different coefficients of thermal expansion are prepared having a reduced probability of failure of stress facture. This is accomplished by narrowing/tapering the material having the lower coefficient of thermal expansion in a direction away from the joint interface and not joining the narrow-tapered surface to the material having the higher coefficient of thermal expansion.

  9. LOW ACTIVATION JOINING OF SIC/SIC COMPOSITES FOR FUSION APPLICATIONS: MODELING DUAL-PHASE MICROSTRUCTURES AND DISSIMILAR MATERIAL JOINTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henager, Charles H.; Nguyen, Ba Nghiep; Kurtz, Richard J.

    2016-03-31

    Finite element continuum damage models (FE-CDM) have been developed to simulate and model dual-phase joints and cracked joints for improved analysis of SiC materials in nuclear environments. This report extends the analysis from the last reporting cycle by including results from dual-phase models and from cracked joint models.

  10. A case series of anophthalmic socket cysts excised utilising fibrin sealant.

    PubMed

    Wong, Yun; Clarke, Lucy; Lau, Gordon

    2017-10-23

    Anophthalmic socket cysts are challenging to remove and incomplete excision has been shown to increase the risk of recurrence. This case series describes a novel technique utilising the fibrin sealant Tisseel (Baxter AG, Vienna, Austria) to retain the socket cyst integrity during surgical removal to facilitate its complete excision. Five patients were included and followed up for a minimum of 1 year, and there were no signs of recurrence in any of the cases. The surgical technique is described and illustrated. This technique is a safe way of simplifying challenging socket cyst surgery.

  11. Shape Memory Polymers: A Joint Chemical and Materials Engineering Hands-On Experience

    ERIC Educational Resources Information Center

    Seif, Mujan; Beck, Matthew

    2018-01-01

    Hands-on experiences are excellent tools for increasing retention of first year engineering students. They also encourage interdisciplinary collaboration, a critical skill for modern engineers. In this paper, we describe and evaluate a joint Chemical and Materials Engineering hands-on lab that explores cross-linking and glass transition in…

  12. Direct Spinal Ventral Root Repair following Avulsion: Effectiveness of a New Heterologous Fibrin Sealant on Motoneuron Survival and Regeneration

    PubMed Central

    Barbizan, Roberta; Seabra Ferreira, Rui

    2016-01-01

    Axonal injuries at the interface between central and peripheral nervous system, such as ventral root avulsion (VRA), induce important degenerative processes, mostly resulting in neuronal and motor function loss. In the present work, we have compared two different fibrin sealants, one derived from human blood and another derived from animal blood and Crotalus durissus terrificus venom, as a promising treatment for this type of injury. Lewis rats were submitted to VRA (L4–L6) and had the avulsed roots reimplanted to the surface of the spinal cord, with the aid of fibrin sealant. The spinal cords were processed to evaluate neuronal survival, synaptic stability, and glial reactivity, 4 and 12 weeks after lesion. Sciatic nerves were processed to investigate Schwann cell activity by p75NTR expression (4 weeks after surgery) and to count myelinated axons and morphometric evaluation (12 weeks after surgery). Walking track test was used to evaluate gait recovery, up to 12 weeks. The results indicate that both fibrin sealants are similarly efficient. However, the snake-derived fibrin glue is a potentially safer alternative for being a biological and biodegradable product which does not contain human blood derivatives. Therefore, the venom glue can be a useful tool for the scientific community due to its advantages and variety of applications. PMID:27642524

  13. Nonsurgical management of an enlarging pneumatocele by fibrin sealant injection via pigtail catheter.

    PubMed

    Park, Tae Hyun; Kim, Jin Kyu

    2016-02-01

    Most pneumatoceles disappear spontaneously and do not cause severe symptoms. Treatment alternatives include various conventional or surgical methods. However, an enlarging, complicated pneumatocele with cardiorespiratory instability requires imaging-guided catheter drainage or surgery. Here, we report the case of a newborn girl with an enlarging pneumatocele accompanied by pulmonary interstitial emphysema secondary to mechanical ventilation. The pneumatocele was successfully managed by the injection of fibrin sealant via a pigtail catheter. © 2015 Wiley Periodicals, Inc.

  14. Development of performance-based guidelines for selection of bituminous-based hot-poured pavement crack sealant : an executive summary report.

    DOT National Transportation Integrated Search

    2009-01-01

    This report summarizes research presented in separate technical reports, papers, and journal articles that collectively document the development of a systematic process to aid in the selection of appropriate bituminous hot-poured sealants for pavemen...

  15. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  16. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  17. A new prosthesis for the metacarpophalangeal joint. Study of materials and biomechanics.

    PubMed

    Petrolati, M; Abbiati, G; Delaria, G; Soffiatti, R; Robotti, P; Guerriero, C

    1999-02-01

    This report discusses the Daphne prosthesis for the metacarpophalangeal joint on the basis of the mechanical, chemical and biological performance of the materials employed. The Daphne prosthesis is a mobile device. The main body is made of a new generation polymethylmetacrylate, while the hinge is made of AISI 316 L stainless steel. Biocompatibility tests were performed on the materials employed. Systemic toxicity, cytotoxicity and contact tests have given favourable results. Mechanical engineering tests have been used to investigate the performances and reliability of the selected materials. The polymethylmetacrylate used in Daphne behaves in a ductile fashion. No mechanical failures were encountered in fatigue tests after 10 million cycles.

  18. Modeling the effect of preexisting joints on normal fault geometries using a brittle and cohesive material

    NASA Astrophysics Data System (ADS)

    Kettermann, M.; van Gent, H. W.; Urai, J. L.

    2012-04-01

    Brittle rocks, such as for example those hosting many carbonate or sandstone reservoirs, are often affected by different kinds of fractures that influence each other. Understanding the effects of these interactions on fault geometries and the formation of cavities and potential fluid pathways might be useful for reservoir quality prediction and production. Analogue modeling has proven to be a useful tool to study faulting processes, although usually the used materials do not provide cohesion and tensile strength, which are essential to create open fractures. Therefore, very fine-grained, cohesive, hemihydrate powder was used for our experiments. The mechanical properties of the material are scaling well for natural prototypes. Due to the fine grain size structures are preserved in in great detail. The used deformation box allows the formation of a half-graben and has initial dimensions of 30 cm width, 28 cm length and 20 cm height. The maximum dip-slip along the 60° dipping predefined basement fault is 4.5 cm and was fully used in all experiments. To setup open joints prior to faulting, sheets of paper placed vertically within the box to a depth of about 5 cm from top. The powder was then sieved into the box, embedding the paper almost entirely. Finally strings were used to remove the paper carefully, leaving open voids. Using this method allows the creation of cohesionless open joints while ensuring a minimum impact on the sensitive surrounding material. The presented series of experiments aims to investigate the effect of different angles between the strike of a rigid basement fault and a distinct joint set. All experiments were performed with a joint spacing of 2.5 cm and the fault-joint angles incrementally covered 0°, 4°, 8°, 12°, 16°, 20° and 25°. During the deformation time lapse photography from the top and side captured every structural change and provided data for post-processing analysis using particle imaging velocimetry (PIV). Additionally

  19. Effect of application of an external teat sealant and/or oral treatment with a monensin capsule pre-calving on the prevalence and incidence of subclinical and clinical mastitis in dairy heifers.

    PubMed

    McDougall, S; Parker, K I; Weir, A M; Compton, C W R

    2008-06-01

    To assess the effect of applying an external teat sealant or a slow-release intraruminal monensin capsule pre-calving on the prevalence and incidence of subclinical or clinical mastitis in dairy heifers post-calving. The studies were undertaken in 13 herds. In two herds application of an external teat sealant was compared with a negative control; in nine herds treatment with monensin was compared with controls, and in two herds treatments were applied in a 2 x 2 factorial design. Heifers were randomly assigned within herd to be treated with a slow-release intraruminal device containing 32 g monensin (n=383), or left as untreated controls (n=389), approximately 30 days before the start of the spring calving period; or to be treated with a latex external teat sealant (n=206) when calving was impending, or be left as untreated controls (n=205). Milk samples were collected from each gland between 0 and 5 days after calving and from any gland diagnosed with clinical mastitis. The effect of the treatments on the prevalence of intramammary infection (IMI), i.e. subclinical mastitis, and clinical mastitis were initially analysed at the univariate level, with associated variables (p<0.2) being used in construction of multivariable models. The prevalence of IMI was 18.4% at the gland level, and coagulase-negative staphylococci followed by Streptococcus uberis were the most common isolates. Treatment with an external teat sealant reduced the prevalence, compared with controls, of any IMI (12.1 (SE 1.7)% vs 16.5 (SE 2.1)%, respectively; p=0.05) or IMI caused by a major pathogen (3.8 (SE 0.8)% vs 6.0 (SE 1.1)%, respectively; p=0.05). Monensin treatment did not affect the prevalence of any IMI (p=0.68) or IMI due to a major pathogen (p=0.11). The cumulative incidence of clinical mastitis was 14.2%. Neither monensin treatment (p=0.47) nor application of an external teat sealant (p=0.71) altered the risk of clinical mastitis. There was no interaction between the monensin and

  20. Influence of irradiation by a novel CO2 9.3-μm short-pulsed laser on sealant bond strength.

    PubMed

    Rechmann, P; Sherathiya, K; Kinsel, R; Vaderhobli, R; Rechmann, B M T

    2017-04-01

    The objective of this in vitro study was to evaluate whether irradiation of enamel with a novel CO 2 9.3-μm short-pulsed laser using energies that enhance caries resistance influences the shear bond strength of composite resin sealants to the irradiated enamel. Seventy bovine and 240 human enamel samples were irradiated with a 9.3-μm carbon dioxide laser (Solea, Convergent Dental, Inc., Natick, MA) with four different laser energies known to enhance caries resistance or ablate enamel (pulse duration from 3 μs at 1.6 mJ/pulse to 43 μs at 14.9 mJ/pulse with fluences between 3.3 and 30.4 J/cm 2 , pulse repetition rate between 4.1 and 41.3 Hz, beam diameter of 0.25 mm and 1-mm spiral pattern, and focus distance of 4-15 mm). Irradiation was performed "freehand" or using a computerized, motor-driven stage. Enamel etching was achieved with 37% phosphoric acid (Scotchbond Universal etchant, 3M ESPE, St. Paul, MN). As bonding agent, Adper Single Bond Plus was used followed by placing Z250 Filtek Supreme flowable composite resin (both 3M ESPE). After 24 h water storage, a single-plane shear bond test was performed (UltraTester, Ultradent Products, Inc., South Jordan, UT). All laser-irradiated samples showed equal or higher bond strength than non-laser-treated controls. The highest shear bond strength values were observed with the 3-μs pulse duration/0.25-mm laser pattern (mean ± SD = 31.90 ± 2.50 MPa), representing a significant 27.4% bond strength increase over the controls (25.04 ± 2.80 MPa, P ≤ 0.0001). Two other caries-preventive irradiation (3 μs/1 mm and 7 μs/0.25 mm) and one ablative pattern (23 μs/0.25 mm) achieved significantly increased bond strength compared to the controls. Bovine enamel also showed in all test groups increased shear bond strength over the controls. Computerized motor-driven stage irradiation did not show superior bond strength values over the clinically more relevant freehand irradiation. Enamel

  1. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.

    PubMed

    Moser, C; Opitz, I; Zhai, W; Rousson, V; Russi, E W; Weder, W; Lardinois, D

    2008-10-01

    Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P < .001), independently of the length of the resection. Prolonged air leak and mean duration of drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P < .001). Autologous fibrin sealant for reinforcement of the staple lines after lung volume reduction surgery significantly reduces prolonged air leak and duration of chest tube drainage.

  2. Bisphenol A and Related Compounds in Dental Materials

    PubMed Central

    Fleisch, Abby F.; Sheffield, Perry E.; Chinn, Courtney; Edelstein, Burton L.; Landrigan, Philip J.

    2014-01-01

    CONTEXT Dental sealants and composite filling materials containing bisphenol A (BPA) derivatives are increasingly used in childhood dentistry. Evidence is accumulating that BPA and some BPA derivatives can pose health risks attributable to their endocrine-disrupting, estrogenic properties. OBJECTIVES To systematically compile and critically evaluate the literature characterizing BPA content of dental materials; to assess BPA exposures from dental materials and potential health risks; and to develop evidence-based guidance for reducing BPA exposures while promoting oral health. METHODS The extant toxicological literature and material safety data sheets were used as data sources. RESULTS BPA is released from dental resins through salivary enzymatic hydrolysis of BPA derivatives, and BPA is detectable in saliva for up to 3 hours after resin placement. The quantity and duration of systemic BPA absorption is not clear from the available data. Dental products containing the bisphenol A derivative glycidyl dimethacrylate (bis-GMA) are less likely to be hydrolyzed to BPA and have less estrogenicity than those containing bisphenol A dimethacrylate (bis-DMA). Most other BPA derivatives used in dental materials have not been evaluated for estrogenicity. BPA exposure can be reduced by cleaning and rinsing surfaces of sealants and composites immediately after placement. CONCLUSIONS On the basis of the proven benefits of resin-based dental materials and the brevity of BPA exposure, we recommend continued use with strict adherence to precautionary application techniques. Use of these materials should be minimized during pregnancy whenever possible. Manufacturers should be required to report complete information on the chemical composition of dental products and encouraged to develop materials with less estrogenic potential. PMID:20819896

  3. An Information Framework for Facility Operators

    DTIC Science & Technology

    1991-01-01

    and replacement products. Type: Type is used to decompose the building into smaller categories called arrangements, assemblies, parts, joints , and forro...are organized into crews and shops consisting of tradepersons responsible for building materials (concrete, masonry, metals, drywall , paint, etc...Comp Type (pre-cast, CIP) AS I Curing compound , sealant tyDe A S 04--- Masonry Comp Type (CMU, stone, glazed) A S I Manufacturer, style no., color no

  4. The modified Ottawa method to establish the update need of a systematic review: glass-ionomer versus resin sealants for caries prevention

    PubMed Central

    MICKENAUTSCH, Steffen; YENGOPAL, Veerasamy

    2013-01-01

    Objective To demonstrate the application of the modified Ottawa method by establishing the update need of a systematic review with focus on the caries preventive effect of GIC versus resin pit and fissure sealants; to answer the question as to whether the existing conclusions of this systematic review are still current; to establish whether a new update of this systematic review was needed. Methods: Application of the Modified Ottawa method. Application date: April/May 2012. Results Four signals aligned with the criteria of the modified Ottawa method were identified. The content of these signals suggest that higher precision of the current systematic review results might be achieved if an update of the current review were conducted at this point in time. However, these signals further indicate that such systematic review update, despite its higher precision, would only confirm the existing review conclusion that no statistically significant difference exists in the caries-preventive effect of GIC and resin-based fissure sealants. Conclusion In conclusion, this study demonstrated the modified Ottawa method as an effective tool in establishing the update need of the systematic review. In addition, it was established that the conclusions of the systematic review in relation to the caries preventive effect of GIC versus resin based fissure sealants are still current, and that no update of this systematic review was warranted at date of application. PMID:24212996

  5. Diffusion of knowledge in dentistry. The pit and fissure sealant conferences.

    PubMed

    Chapko, M K

    1988-01-01

    This paper presents data on the diffusion to dentists of information from the May 1981 American Dental Association conference and December 1983 National Institutes of Health (NIH) conference on pit and fissure sealants. A mail survey was sent to 521 (72.2% returned) randomly selected dentists in general practice and all 47 (76.6% returned) pedodontists in the State of Washington. Approximately 70% of the dentists were aware that the conferences had taken place and a little over 50% were aware of the conference recommendations. Awareness was related to: being a pedodontist, number of continuing education hours taken, number of referred journals read, and being an officer in a dental organization.

  6. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    PubMed Central

    Avgoulas, Evangelos I.; Sutcliffe, Michael P. F.

    2016-01-01

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints. PMID:28773688

  7. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints.

    PubMed

    Avgoulas, Evangelos I; Sutcliffe, Michael P F

    2016-07-12

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  8. Application of a new collagen-based sealant for the treatment of pancreatic injury.

    PubMed

    Rosen, Michael; Walsh, R Matthew; Goldblum, John R

    2004-08-01

    Pancreatic injury is the most frequent serious morbidity that can occur following laparoscopic splenectomy. The presumed mechanism of injury is direct trauma to the pancreatic tail during hilar dissection or transection with endovascular staplers. It was our aim to study the direct application of topical sealants to a pancreatic injury to prevent a pancreatic leak. A porcine model of pancreatic injury in a normal pancreas was developed. Fourteen animals underwent midline laparotomy and subtotal (8 cm) distal pancreatectomy. The pancreas was sharply divided and minimal cauterization used. A (1/4)-inch round Jackson Pratt drain was secured to the pancreatic stump in all animals. The control group (n = 7) underwent no further treatment. Two groups underwent treatment with a sealant. Group 1 (n = 3) had a hydrogel applied to the pancreatic remnant. Group 2 (n = 4) had a biodegradable sealant of PEG (polyethylene glycol)-collagen formulation applied to the pancreatic stump by aerosol. During the postoperative period, animals were fed 2.2 lb/d of a high fat (10% lard) diet to stimulate pancreatic exocrine function. Total daily drain outputs were recorded, and drain amylase content and serum amylase concentration were measured on postoperative days 3, 7, and 10. A significant pancreatic leak was defined as a drain to serum amylase content of greater than 3:1. Animals were killed on day 10 and explored for undrained fluid collections. The pancreas was removed for histologic evaluation. Control and treatment groups were compared using repeated measures ANOVA of log-transformed data. All animals survived until elective necropsy. In group 1, average total drain outputs were not significantly less than the controls (125 mL versus 269; P = .66). The mean drain/serum amylase concentration on days 3, 7, and 10 were not significantly different between group 1 and the control group. Group 2 had significantly less overall average drainage output than controls (40 mL versus 269 mL; P

  9. Changes in Caries Experience, Untreated Caries, Sealant Prevalence, and Preventive Behavior Among Third-Graders in New York State, 2002-2004 and 2009-2012.

    PubMed

    Kumar, Jayanth V; Tavares, Vinicius; Kandhari, Priyanka; Moss, Mark; Jolaoso, I Adeyemi

    2015-01-01

    This study assessed changes in caries experience, untreated caries, sealant prevalence, and preventive behavior among third-grade children in New York State to monitor progress toward state health objectives. We analyzed children's data from the 2002-2004 (n=10,865) and 2009-2012 (n=6,758) New York State Oral Health Survey. We calculated differences in weighted percentages and 95% confidence intervals for caries experience, untreated caries, sealant prevalence, and preventive behavior. We used logistic regression procedures to assess the independent effects and interaction terms on dental caries experience. The percentage of children with dental caries and untreated caries decreased from 54.1% and 33.0% in 2002-2004 to 45.2% and 23.6% in 2009-2012, respectively. While this decrease was not uniform across income subgroups, the prevalence of sealants, a key measure of the use of preventive services, increased significantly from 16.7% to 36.0% among lower-income children. Measurable improvement in reducing dental caries prevalence among third-grade children has been made in New York State, but this improvement was not uniform across subgroups. Specifically, disease prevalence among lower-income children remained high, underscoring the need to strengthen existing programs and identify additional policy and programmatic interventions.

  10. Field joint protection system rain qualification test report

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1989-01-01

    This report documents the procedures, performance, and results obtained from the Field Joint Protection System (FJPS) rain test. This test was performed to validate that the flight configuration FJPS prevents the accumulation of moisture in the redesigned solid rocket motor (RSRM) field joints when subjected to simulated prelaunch natural rain environments. The FJPS test article was exposed to rain simulation for approximately 50 minutes. During the test, water entered through the open upper end of the systems tunnel and was funneled down between the tunnel and case. A sealant void at the moisture seal butt splice allowed this water to flow underneath the FJPS. The most likely cause of voids was improper bondline preparation, particularly on the moisture seal surface. In total, water penetrated underneath approximately 60 percent of the FJPS circumference. Because the test article was substantially different from flight configuration (no systems tunnel closeout), results of this test will not affect current flight motors. Due to the omission of systems tunnel covers and systems tunnel floor plate closeout, the test assembly was not representative of flight hardware and resulted in a gross overtest. It is therefore recommended that the test be declared void. It is also recommended that the test be repeated with a complete closeout of the systems tunnel, sealed systems tunnel ends, and improved adhesive bondline preparation.

  11. Polymers Advance Heat Management Materials for Vehicles

    NASA Technical Reports Server (NTRS)

    2013-01-01

    For 6 years prior to the retirement of the Space Shuttle Program, the shuttles carried an onboard repair kit with a tool for emergency use: two tubes of NOAX, or "good goo," as some people called it. NOAX flew on all 22 flights following the Columbia accident, and was designed to repair damage that occurred on the exterior of the shuttle. Bill McMahon, a structural materials engineer at Marshall Space Flight Center says NASA needed a solution for the widest range of possible damage to the shuttle s exterior thermal protection system. "NASA looked at several options in early 2004 and decided on a sealant. Ultimately, NOAX performed the best and was selected," he says. To prove NOAX would work effectively required hundreds of samples manufactured at Marshall and Johnson, and a concerted effort from various NASA field centers. Johnson Space Center provided programmatic leadership, testing, tools, and crew training; Glenn Research Center provided materials analysis; Langley Research Center provided test support and led an effort to perform large patch repairs; Ames Research Center provided additional testing; and Marshall provided further testing and the site of NOAX manufacturing. Although the sealant never had to be used in an emergency situation, it was tested by astronauts on samples of reinforced carbon-carbon (RCC) during two shuttle missions. (RCC is the thermal material on areas of the shuttle that experience the most heat, such as the nose cone and wing leading edges.) The material handled well on orbit, and tests showed the NOAX patch held up well on RCC.

  12. Color stability of sealed composite resin restorative materials after ultraviolet artificial aging and immersion in staining solutions.

    PubMed

    Catelan, Anderson; Briso, André Luiz Fraga; Sundfeld, Renato Hermann; Goiato, Marcelo Coelho; dos Santos, Paulo Henrique

    2011-04-01

    The color alteration of resin-based materials is one of the most common reasons to replace esthetic dental restorations. This study assessed the influence of surface sealant (Biscover) on the color stability of nanofilled (Supreme XT) and microhybrid (Vit-l-escence and Opallis) composite resins after artificial aging. One hundred disc-shaped (6 × 1.5 mm) specimens were made for each composite resin. After 24 hours, all specimens were polished and sealant was applied to 50 specimens of each material. Baseline color was measured according to the CIE L*a*b* system using a reflection spectrophotometer. Ten specimens of each group were aged for 252 h in an ultraviolet (UV)-accelerated aging chamber or immersed for 4 weeks in cola soft drink, orange juice, red wine staining solutions or distilled water as control. Color difference (ΔE) after aging was calculated based on the color coordinates before (baseline) and after aging/staining treatment. Data were analyzed with 2-way ANOVA and Fisher's test (α=.05). The results showed significant changes in color after artificial aging in all the groups (P<.05). Independent of the material studied, red wine resulted in the highest level of discoloration. Intermediate values were found for orange juice, UV accelerated aging, and the cola soft drink. The lowest values of ΔE were found for specimens stored in distilled water. All composite resins showed some color alteration after the aging methods. The surface sealant did not alter the color stability of the tested materials. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. Applying psychological theories to evidence-based clinical practice: identifying factors predictive of placing preventive fissure sealants.

    PubMed

    Bonetti, Debbie; Johnston, Marie; Clarkson, Jan E; Grimshaw, Jeremy; Pitts, Nigel B; Eccles, Martin; Steen, Nick; Thomas, Ruth; Maclennan, Graeme; Glidewell, Liz; Walker, Anne

    2010-04-08

    Psychological models are used to understand and predict behaviour in a wide range of settings, but have not been consistently applied to health professional behaviours, and the contribution of differing theories is not clear. This study explored the usefulness of a range of models to predict an evidence-based behaviour -- the placing of fissure sealants. Measures were collected by postal questionnaire from a random sample of general dental practitioners (GDPs) in Scotland. Outcomes were behavioural simulation (scenario decision-making), and behavioural intention. Predictor variables were from the Theory of Planned Behaviour (TPB), Social Cognitive Theory (SCT), Common Sense Self-regulation Model (CS-SRM), Operant Learning Theory (OLT), Implementation Intention (II), Stage Model, and knowledge (a non-theoretical construct). Multiple regression analysis was used to examine the predictive value of each theoretical model individually. Significant constructs from all theories were then entered into a 'cross theory' stepwise regression analysis to investigate their combined predictive value. Behavioural simulation - theory level variance explained was: TPB 31%; SCT 29%; II 7%; OLT 30%. Neither CS-SRM nor stage explained significant variance. In the cross theory analysis, habit (OLT), timeline acute (CS-SRM), and outcome expectancy (SCT) entered the equation, together explaining 38% of the variance. Behavioural intention - theory level variance explained was: TPB 30%; SCT 24%; OLT 58%, CS-SRM 27%. GDPs in the action stage had significantly higher intention to place fissure sealants. In the cross theory analysis, habit (OLT) and attitude (TPB) entered the equation, together explaining 68% of the variance in intention. The study provides evidence that psychological models can be useful in understanding and predicting clinical behaviour. Taking a theory-based approach enables the creation of a replicable methodology for identifying factors that may predict clinical behaviour

  14. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation

    PubMed Central

    Fortelny, René H.; Petter-Puchner, Alexander H.; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Results: Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Conclusion: Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair. PMID:25593969

  15. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation.

    PubMed

    Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  16. Assessment of microleakage of class V restored by resin composite and resin-modified glass ionomer and pit and fissure resin-based sealants following Er:YAG laser conditioning and acid etching: in vitro study

    PubMed Central

    Luong, Emilie; Shayegan, Amir

    2018-01-01

    Aim The aim of this study was to make a comparison between microleakage of conventionally restored class V cavities using acid etchant and the ones conditioned by erbium-doped yttrium aluminum garnet (Er:YAG) laser, and also to assess and compare the effectiveness of enamel surface treatments of occlusal pits and fissures by acid etching and conditioned by Er:YAG laser-etch. Materials and methods Seventy-two extracted third molars were used in this study. The samples were divided into two major groups: class V cavities and pit and fissure sealants. Each subgroup was divided into conventional acid etching, Er:YAG laser conditioning and conventional acid etching, and combination with Er:YAG laser conditioning (n=12). The teeth were placed in 2% methylene blue dye solution, were sectioned, and were evaluated according to the dye penetration criteria. Two samples per subgroup were chosen for scanning electron microscopic (SEM) analysis. Results There was a significant difference between occlusal and cervical margin groups. Laser conventional composite cementum group showed more microleakage values compared to other groups. There was no significant difference between occlusal margin groups. However, there was a significant difference between cervical margin groups in terms of microleakage. In sealant groups, there was a significant difference between laser and conventional with/without laser treatment groups in terms of microleakage. Conclusion Based on the results reported in this study, it can be concluded that the application of the Er:YAG laser beneath the resin composite, the resin-modified glass ionomers (GIs), and the fissure sealant placement may be an alternative enamel and dentin etching method to acid etching. PMID:29881311

  17. Solving an emergency rescue materials problem under the joint reserves mode of government and framework agreement suppliers

    PubMed Central

    Sun, Xiao-Qing; Zhu, Rui; Li, Ming; Miao, Wang

    2017-01-01

    Emergency rescue material reserves are vital for the success of emergency rescue activities. In this study, we consider a situation where a government owned distribution center and framework agreement suppliers jointly store emergency rescue materials. Using a scenario-based approach to represent demand uncertainty, we propose a comprehensive transportation pattern for the following supply chain: “suppliers—government distribution center—disaster area.” Using a joint reserves model that includes the government and framework agreement suppliers, we develop a non-linear mathematic model that determines the choices of the framework suppliers, the corresponding optimal commitment quantities, and the quantity of materials that are stored at a government distribution center. Finally, we use IBM ILOG CPLEX to solve the numerical examples to verify the effectiveness of the mode and perform sensitivity analyses on the relevant parameters. PMID:29077722

  18. The extraordinary joint material of an articulated coralline alga. II. Modeling the structural basis of its mechanical properties.

    PubMed

    Denny, Mark W; King, Felicia A

    2016-06-15

    By incorporating joints into their otherwise rigid fronds, erect coralline algae have evolved to be as flexible as other seaweeds, which allows them to thrive - and even dominate space - on wave-washed shores around the globe. However, to provide the required flexibility, the joint tissue of Calliarthron cheilosporioides, a representative articulated coralline alga, relies on an extraordinary tissue that is stronger, more extensible and more fatigue resistant than that of other algae. Here, we used the results from recent experiments to parameterize a conceptual model that links the microscale architecture of cell walls to the adaptive mechanical properties of joint tissue. Our analysis suggests that the theory of discontinuous fiber-wound composite materials (with cellulose fibrils as the fibers and galactan gel as the matrix) can explain key aspects of the material's mechanics. In particular, its adaptive viscoelastic behavior can be characterized by two, widely separated time constants. We speculate that the short time constant (∼14 s) results from the viscous response of the matrix to the change in cell-wall shape as a joint is stretched, a response that allows the material both to remain flexible and to dissipate energy as a frond is lashed by waves. We propose that the long time constant (∼35 h), is governed by the shearing of the matrix between cellulose fibrils. The resulting high apparent viscosity ensures that joints avoid accumulating lethal deformation in the course of a frond's lifetime. Our synthesis of experimental measurements allows us to draw a chain of mechanistic inference from molecules to cell walls to fronds and community ecology. © 2016. Published by The Company of Biologists Ltd.

  19. Torque vs. induced load of A-286, and MP35N nuts and bolts with cadmium, dry film, and cetyl alcohol lubricants

    NASA Technical Reports Server (NTRS)

    Crispell, C.

    1978-01-01

    Data for specific joint design, utilizing various combinations of bolt, nut and lubricants in typical structure of the shuttle booster rocket is obtained. Requirements of the structure performance criteria were to withstand temperatures of 260 C (500 F) and to provide a nut lubricant which would be compatible with sealants used in the joint. Cadmium plating and dry film lubricant meeting the requirements of MIL-L-8937 were the lubricants specified. In a follow up effort, cadmium plating and cetyl alcohol were further specified The materials for the bolt and nut combinations were MP35N and A-286. These materials demand a lubricant to be used to prevent galling of the thread when tightened and also to help reduce the scatter of clamping load in application.

  20. Beyond Coordination: Joint Planning and Program Execution. The IHPRPT Materials Working Group

    NASA Technical Reports Server (NTRS)

    Stropki, Michael A.; Cleyrat, Danial A.; Clinton, Raymond G., Jr.; Rogacki, John R. (Technical Monitor)

    2000-01-01

    "Partnership is more than just coordination," stated then-Commander of the Air Force Research Laboratory (AFRL), Major General Dick Paul (USAF-Ret), at this year's National Space and Missile Materials Symposium. His comment referred to the example of the joint planning and program execution provided by the Integrated High Payoff Rocket Propulsion Technology (IHPRPT) Materials Working Group (IMWG). Most people agree that fiscal pressures imposed by shrinking budgets have made it extremely difficult to build upon our existing technical capabilities. In times of sufficient budgets, building advanced systems poses no major difficulties. However, with today's budgets, realizing enhanced capabilities and developing advanced systems often comes at an unaffordable cost. Overcoming this problem represents both a challenge and an opportunity to develop new business practices that allow us to develop advanced technologies within the restrictions imposed by current funding levels. Coordination of technology developments between different government agencies and organizations is a valuable tool for technology transfer. However, rarely do the newly developed technologies have direct applicability to other ongoing programs. Technology requirements are typically determined up-front during the program planning stage so that schedule risk can be minimized. The problem with this process is that the costs associated with the technology development are often borne by a single program. Additionally, the potential exists for duplication of technical effort. Changing this paradigm is a difficult process but one that can be extremely worthwhile should the right opportunity arise. The IMWG is one such example where NASA, the DoD, and industry have developed joint requirements that are intended to satisfy multiple program needs. More than mere coordination, the organizations comprising the group come together as partners, sharing information and resources, proceeding from a joint roadmap.

  1. Electrical behavior of aluminosilicate glass-ceramic sealants and their interaction with metallic solid oxide fuel cell interconnects

    NASA Astrophysics Data System (ADS)

    Goel, Ashutosh; Tulyaganov, Dilshat U.; Kharton, Vladislav V.; Yaremchenko, Aleksey A.; Ferreira, José M. F.

    A series of alkaline-earth aluminosilicate glass-ceramics (GCs) were appraised with respect to their suitability as sealants for solid oxide fuel cells (SOFCs). The parent composition with general formula Ca 0.9MgAl 0.1La 0.1Si 1.9O 6 was modified with Cr 2O 3 and BaO. The addition of BaO led to a substantial decrease in the total electrical conductivity of the GCs, thus improving their insulating properties. BaO-containing GCs exhibited higher coefficient of thermal expansion (CTE) in comparison to BaO-free GCs. An extensive segregation of oxides of Ti and Mn, components of the Crofer22 APU interconnect alloy, along with negligible formation of BaCrO 4 was observed at the interface between GC/interconnects diffusion couples. Thermal shock resistance and gas-tightness of GC sealants in contact with yttria-stabilized zirconia electrolyte (8YSZ) was evaluated in air and water. Good matching of CTE and strong, but not reactive, adhesion to the solid electrolyte and interconnect, in conjunction with a high level of electrical resistivity, are all advantageous for potential SOFC applications.

  2. Effectiveness of audiovisual distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder

    PubMed Central

    Fakhruddin, Kausar Sadia; El Batawi, Hisham Yehia

    2017-01-01

    Background: The aim of this study was to evaluate the effectiveness of audiovisual (AV) distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder. Materials and Methods: This study was conducted on 28 children diagnosed with autism spectrum disorder, aged 6.5−9.8 years. Children underwent one introductory (desensitization) appointment and three treatment sessions. During the introductory session, children had the procedures explained to them, they watched a movie projected on a screen while oral screening and assessment of cooperation level were carried out. In treatment session I, oral examination, charting, and dental x-rays were undertaken, whereas the children watched movies with or without video eyewear. During treatment sessions II/III, dental prophylaxis was carried out on upper and lower jaws in addition to the application of dental sealants on the right upper and lower and the left upper and lower permanent molars, respectively, while the children were distracted by cartoon movies using video eyewear. Changes in pulse oximeter and heart rate were recorded every 5 min. Independent samples t-test was used to assess the significance of changes in pulse and O2 saturation levels during each visit. Results: International Caries Detection and Assessment System-code 2 was found to be the most prevalent (n = 58; 52%). A significant difference (P < 0.02) was observed in mean heart rate during dental screening of the upper and lower jaws with and without video eyewear. A decrease was observed in the mean heart rate during subsequent treatment sessions. Conclusion: Initial desensitization appointment and “tell-show-do” approach, followed by short and positive treatment sessions, assisted in gaining cooperation and improving behavior in the subjects. Video eyewear distraction proved an effective tool in managing children with autism spectrum disorder during noninvasive preventive dental

  3. Joint Strength Control at the Fiber/Matrix Interface during the Production of Polymer Composite Materials Reinforced with High Performance Fibers

    NASA Astrophysics Data System (ADS)

    Kudinov, Vladimir V.; Korneeva, Natalia V.

    2010-06-01

    The paper presents the results obtained in the study of the joint strength between polymer matrix and high performance polyethylene fiber. The fiber/matrix joints simulate the unit cell of the fiber-reinforced composite materials. Effect of heat treatment on the composite properties at the interface was estimated by a multifilament wet-pull-out method. It was found that the joint strength may be increased with the help of extra heart treatment. Both the energy to peak load and the energy to failure for CM joints at various stages of loading were determined.

  4. Wormhole Formation in RSRM Nozzle Joint Backfill

    NASA Technical Reports Server (NTRS)

    Stevens, J.

    2000-01-01

    The RSRM nozzle uses a barrier of RTV rubber upstream of the nozzle O-ring seals. Post flight inspection of the RSRM nozzle continues to reveal occurrence of "wormholes" into the RTV backfill. The term "wormholes", sometimes called "gas paths", indicates a gas flow path not caused by pre-existing voids, but by a little-understood internal failure mode of the material during motor operation. Fundamental understanding of the mechanics of the RSRM nozzle joints during motor operation, nonlinear viscoelastic characterization of the RTV backfill material, identification of the conditions that predispose the RTV to form wormholes, and screening of candidate replacement materials is being pursued by a joint effort between Thiokol Propulsion, NASA, and the Army Propulsion & Structures Directorate at Redstone Arsenal. The performance of the RTV backfill in the joint is controlled by the joint environment. Joint movement, which applies a tension and shear load on the material, coupled with the introduction of high pressure gas in combination create an environment that exceeds the capability of the material to withstand the wormhole effect. Little data exists to evaluate why the material fails under the modeled joint conditions, so an effort to characterize and evaluate the material under these conditions was undertaken. Viscoelastic property data from characterization testing will anchor structural analysis models. Data over a range of temperatures, environmental pressures, and strain rates was used to develop a nonlinear viscoelastic model to predict material performance, develop criteria for replacement materials, and quantify material properties influencing wormhole growth. Three joint simulation analogs were developed to analyze and validate joint thermal barrier (backfill) material performance. Two exploratory tests focus on detection of wormhole failure under specific motor operating conditions. A "validation" test system provides data to "validate" computer models and

  5. Using three dimensional silicone ``boots`` to solve complex remedial design problems in curtain walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Y.J.

    1998-12-31

    Stick system curtain wall leak problems are frequently caused by water entry at the splice joints of the curtain wall frame and failure of the internal metal joinery seals. Remedial solutions involving occupied buildings inevitably face the multiple constraints of existing construction and business operations not present during the original curtain wall construction. In most cases, even partial disassembly of the curtain wall for internal seal repairs is not feasible. Remedial solutions which must be executed from the exterior of the curtain wall often involve wet-applied or preformed sealant tape bridge joints. However, some of the more complex joints cannotmore » be repaired effectively or economically with the conventional bridge joint. Fortunately, custom fabricated three-dimensional preformed sealant boots are becoming available to address these situations. This paper discusses the design considerations and the selective use of three-dimensional preformed boots in sealing complex joint geometry that would not be effective with the conventional two-dimensional bridge joint.« less

  6. A polymeric sealant inhibits anastomotic suture hole bleeding more rapidly than gelfoam/thrombin: results of a randomized controlled trial.

    PubMed

    Glickman, Marc; Gheissari, Ali; Money, Samuel; Martin, John; Ballard, Jeffrey L

    2002-03-01

    An experimental polymeric sealant (CoSeal [Cohesion Technologies, Palo Alto, Calif]) provides equivalent anastomotic sealing to Gelfoam (Upjohn, Kalamazoo, Mich)/thrombin during surgical placement of prosthetic vascular grafts. Randomized controlled trial. Nine university-affiliated medical centers. One hundred forty-eight patients scheduled for implantation of polytetrafluoroethylene grafts, mainly for infrainguinal revascularization procedures or the creation of dialysis access shunts, who were treated randomly with either an experimental intervention (n = 74) or control (n = 74). Following polytetrafluoroethylene graft placement, anastomotic suture hole bleeding was treated intraoperatively in all control subjects with Gelfoam/thrombin. Subjects in the experimental group had the polymeric sealant applied directly to the suture lines without concomitant manual compression. Primary treatment success was defined as the proportion of subjects in each group that achieved complete anastomotic sealing within 10 minutes. The proportion of subjects that achieved immediate sealing and the time required to fully inhibit suture hole bleeding also were compared between treatment groups. Overall 10-minute sealing success was equivalent (86% vs 80%; P =.29) between experimental and control subjects, respectively. However, subjects treated with CoSeal achieved immediate anastomotic sealing at more than twice the rate of subjects treated with Gelfoam/thrombin (47% vs 20%; P<.001). Consequently, the median time needed to inhibit bleeding in control subjects was more than 10 times longer than for experimental subjects (16.5 seconds vs 189.0 seconds; P =.01). Strikingly similar findings for all comparisons were observed separately for subgroups of subjects having infrainguinal bypass grafting and for those undergoing placement of dialysis access shunts. The experimental sealant offers equivalent anastomotic sealing performance compared with Gelfoam/thrombin, but it provides this

  7. Method of forming a joint

    DOEpatents

    Butt, Darryl Paul; Cutler, Raymond Ashton; Rynders, Steven Walton; Carolan, Michael Francis

    2006-08-22

    A method of joining at least two sintered bodies to form a composite structure, including providing a first multicomponent metallic oxide having a perovskitic or fluorite crystal structure; providing a second sintered body including a second multicomponent metallic oxide having a crystal structure of the same type as the first; and providing at an interface a joint material containing at least one metal oxide containing at least one metal identically contained in at least one of the first and second multicomponent metallic oxides. The joint material is free of cations of Si, Ge, Sn, Pb, P and Te and has a melting point below the sintering temperatures of both sintered bodies. The joint material is heated to a temperature above the melting point of the metal oxide(s) and below the sintering temperatures of the sintered bodies to form the joint. Structures containing such joints are also disclosed.

  8. Low Activation Joining of SiC/SiC Composites for Fusion Applications: Thermomechanical Modeling of Dual-Phase Microstructures and Dissimilar Material Joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Ba Nghiep; Henager, Charles H.; Kurtz, Richard J.

    2016-09-30

    Finite element (FE) continuum damage mechanics (CDM) models have been developed to simulate and model dual-phase joints and cracked joints for improved analysis of SiC materials in nuclear environments. This report extends the analysis from the last reporting cycle by including preliminary thermomechanical analyses of cracked joints and implementation of dual-phase damage models.

  9. Seawater Corrosion of Fasteners in Various Structural Materials

    DTIC Science & Technology

    1976-04-01

    17 - 4PH stainless steel. The seven bolt materials were: 2024 aluminum, anodized ASTM grade 5 steel, 304 and 316 stainless steels, A286 stain- less...performed well in titanium structures. Use of MP35N, A286, and 304 stainless steel fasteners for constantly immersed 17 - 4PH stainless steel structures...would have been satisfactory only if sealant was not used and if protection had been provided to the 17 - 4PH to minimize crevice corrosion. Additional

  10. Influences of Nozzle Material on Laser Droplet Brazing Joints with Cu89Sn11 Preforms

    NASA Astrophysics Data System (ADS)

    Stein, Stefan; Heberle, Johannes; Gürtler, Franz Josef; Cvecek, Kristian; Roth, Stephan; Schmidt, Michael

    This paper presents latest results on the influences of nozzle material and geometry on the electromechanical contacting of sensitive piezoceramic actuator modules. Two nozzle types have been investigated,a standard WC/Co nozzle which is used for soldering applications and a novelceramic nozzle. Applications for active piezoceramic components integrated in structural parts are e.g. active damping, energy harvesting, or monitoring of vibrations and material failure. Anup to now unsolved problem is the electrical contacting of such components without damaging the conductor or the metallization of the ceramic substrate. Since piezoelectric components are to be integrated into structures made of casted aluminum, requirements are high mechanical strength and temperature resistance. Within this paper a method forcontacting piezoceramic modules is presented. A spherical braze preform of tin bronze Cu89Sn11 with a diameter of 600 μm is located in a ceramic nozzle and is subsequently melted by a laser pulse. The liquid solder is ejected from the nozzlevia nitrogen overpressure and wets the surface of the metallization pad and the Cu-wire, resulting in a brazing joint after solidification. The process is called laser droplet brazing (LDB). To asses the thermal evolution during one cycle WC/Co and ZTA have been simulated numerically for two different geometries enabling a proposition weather the geometry or the material properties have a significant influence on the thermal load during one cycle. To evaluate the influence of the nozzle on the joint the positioning accuracy, joint height and detachment times have been evaluated. Results obtained with the ZTA nozzle show comparable positioning accuracies to a WC/Co nozzle with a lower standard deviation of solder detachment time.

  11. Fate and Transport of Chemical Warfare Agents VX and HD ...

    EPA Pesticide Factsheets

    Report The intent of this investigation was to study the fate and transport of CWA applied to painted/sealed materials including the potential partitioning of CWA into permeable paints/sealants and subsequently into underlying porous materials. Based on the results obtained from this investigation, VX and sulfur mustard (HD) have the ability to permeate into paints and sealants, including in some cases the underlying porous materials. It is likely that other permeable materials besides paints and sealants may also show similar behavior.

  12. Design, Static Analysis And Fabrication Of Composite Joints

    NASA Astrophysics Data System (ADS)

    Mathiselvan, G.; Gobinath, R.; Yuvaraja, S.; Raja, T.

    2017-05-01

    The Bonded joints will be having one of the important issues in the composite technology is the repairing of aging in aircraft applications. In these applications and also for joining various composite material parts together, the composite materials fastened together either using adhesives or mechanical fasteners. In this paper, we have carried out design, static analysis of 3-D models and fabrication of the composite joints (bonded, riveted and hybrid). The 3-D model of the composite structure will be fabricated by using the materials such as epoxy resin, glass fibre material and aluminium rivet for preparing the joints. The static analysis was carried out with different joint by using ANSYS software. After fabrication, parametric study was also conducted to compare the performance of the hybrid joint with varying adherent width, adhesive thickness and overlap length. Different joint and its materials tensile test result have compared.

  13. Ohio Route 50 joint sealant experiment.

    DOT National Transportation Integrated Search

    2002-03-01

    This is the third and Final Report for a research project that entailed the construction and evaluation to date of a stretch of a four-lane highway near Athens, Ohio. The main purpose of this project has been to evaluate concrete pavement performance...

  14. Ohio Route 50 Joint Sealant Experiment.

    DOT National Transportation Integrated Search

    2002-04-01

    This is the third and Final Report for a research project that entailed the construction and evaluation to date of a stretch of a four-lane highway near Athens, Ohio. The main purpose of this project had been to evaluate concrete pavement in connecti...

  15. Biomimetic-inspired joining of composite with metal structures: A survey of natural joints and application to single lap joints

    NASA Astrophysics Data System (ADS)

    Avgoulas, Evangelos Ioannis; Sutcliffe, Michael P. F.

    2014-03-01

    Joining composites with metal parts leads, inevitably, to high stress concentrations because of the material property mismatch. Since joining composite to metal is required in many high performance structures, there is a need to develop a new multifunctional approach to meet this challenge. This paper uses the biomimetics approach to help develop solutions to this problem. Nature has found many ingenious ways of joining dissimilar materials and making robust attachments, alleviating potential stress concentrations. A literature survey of natural joint systems has been carried out, identifying and analysing different natural joint methods from a mechanical perspective. A taxonomy table was developed based on the different methods/functions that nature successfully uses to attach dissimilar tissues (materials). This table is used to understand common themes or approaches used in nature for different joint configurations and functionalities. One of the key characteristics that nature uses to joint dissimilar materials is a transitional zone of stiffness in the insertion site. Several biomimetic-inspired metal-to-composite (steel-to-CFRP), adhesively bonded, Single Lap Joints (SLJs) were numerically investigated using a finite element analysis. The proposed solutions offer a transitional zone of stiffness of one joint part to reduce the material stiffness mismatch at the joint. An optimisation procedure was used to identify the variation in material stiffness which minimises potential failure of the joint. It was found that the proposed biomimetic SLJs reduce the asymmetry of the stress distribution along the adhesive area.

  16. Development of test apparatus for service life prediction of sealant formulations and evaluation of data from 18 months of outdoor weathering

    Treesearch

    R. Sam Williams; Steve Lacher; Corey Halpin; Christopher White

    2004-01-01

    The focus of this report is to describe the results from seven different sealant formulations exposed for up to 18 months. The methods used to evaluate the data are described, the difficulties encountered in analyzing the data are discussed, and new developments in the test apparatus are presented.

  17. Silver microparticles plus fibrin tissue sealant prevents incisional hernias in rats.

    PubMed

    Primus, Frank E; Young, David M; Grenert, James P; Harris, Hobart W

    2018-07-01

    Open abdominal surgery is frequently complicated by the subsequent development of an incisional hernia. Consequently, more than 400,000 incisional hernia repairs are performed each year, adding over $15 billion per year to U.S. health-care expenditures. While the vast majority of studies have focused on improved surgical techniques or prosthetic materials, we examined the use of metallic silver microparticles to prevent incisional hernia formation through enhanced wound healing. A rodent incisional hernia model was used. Eighty-two rats were randomly placed into two control groups (saline alone and silver microparticles alone), and three experimental groups (0 mg/cm, 2.5 mg/cm, and 25 mg/cm of silver microparticles applied with a fibrin sealant). Incisional hernia incidence and size, tensile strength, and tissue histology were assessed after 28 days. A significant reduction of both incisional hernia incidence and hernia size was observed between the control groups and 2.5 mg/cm group, and between the control and 25 mg/cm group by nearly 60% and 90%, respectively (P < 0.05). Histological samples showed a noticeable increase in new fibrosis in the treated animals as compared with the controls, whereas the tensile strength between the groups did not differ. The novel approach of using silver microparticles to enhance wound healing appears to be a safe and effective method to prevent incisional hernias from developing and could herald a new era of medicinal silver use. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. 78 FR 8202 - Meeting of the Joint ACRS Subcommittees on Thermal Hydraulic Phenomena and Materials, Metallurgy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-05

    ... NUCLEAR REGULATORY COMMISSION Advisory Committee on Reactor Safeguards (ACRS) Meeting of the Joint ACRS Subcommittees on Thermal Hydraulic Phenomena and Materials, Metallurgy and Reactor Fuels; Notice... Reactor Fuels will hold a meeting on February 20, 2013, Room T-2B1, 11545 Rockville Pike, Rockville...

  19. Characterization of Fast-Scan Cyclic Voltammetric Electrodes Using Paraffin as an Effective Sealant with In Vitro and In Vivo Applications

    PubMed Central

    Ramsson, Eric S.; Cholger, Daniel; Dionise, Albert; Poirier, Nicholas; Andrus, Avery; Curtiss, Randi

    2015-01-01

    Fast-scan cyclic voltammetry (FSCV) is a powerful technique for measuring sub-second changes in neurotransmitter levels. A great time-limiting factor in the use of FSCV is the production of high-quality recording electrodes; common recording electrodes consist of cylindrical carbon fiber encased in borosilicate glass. When the borosilicate is heated and pulled, the molten glass ideally forms a tight seal around the carbon fiber cylinder. It is often difficult, however, to guarantee a perfect seal between the glass and carbon. Indeed, much of the time spent creating electrodes is in an effort to find a good seal. Even though epoxy resins can be useful in this regard, they are irreversible (seals are permanent), wasteful (epoxy cannot be reused once hardener is added), hazardous (hardeners are often caustic), and require curing. Herein we characterize paraffin as an electrode sealant for FSCV microelectrodes. Paraffin boasts the advantages of near-immediate curing times, simplicity in use, long shelf-life and stable waterproof seals capable of withstanding extended cycling. Borosilicate electrode tips were left intact or broken and dipped in paraffin embedding wax. Excess wax was removed from the carbon surface with xyelenes or by repeated cycling at an extended waveform (-0.4 to 1.4V, 400 V/s, 60 Hz). Then, the waveform was switched to a standard waveform (-0.4 to 1.3V, 400 V/s, 10 Hz) and cycled until stable. Wax-sealing does not inhibit electrode sensitivity, as electrodes detected linear changes in dopamine before and after wax (then xylenes) exposure. Paraffin seals are intact after 11 days of implantation in the mouse, and still capable of measuring transient changes in in vivo dopamine. From this it is clear that paraffin wax is an effective sealant for FSCV electrodes that provides a convenient substitute to epoxy sealants. PMID:26505195

  20. Characterization of Fast-Scan Cyclic Voltammetric Electrodes Using Paraffin as an Effective Sealant with In Vitro and In Vivo Applications.

    PubMed

    Ramsson, Eric S; Cholger, Daniel; Dionise, Albert; Poirier, Nicholas; Andrus, Avery; Curtiss, Randi

    2015-01-01

    Fast-scan cyclic voltammetry (FSCV) is a powerful technique for measuring sub-second changes in neurotransmitter levels. A great time-limiting factor in the use of FSCV is the production of high-quality recording electrodes; common recording electrodes consist of cylindrical carbon fiber encased in borosilicate glass. When the borosilicate is heated and pulled, the molten glass ideally forms a tight seal around the carbon fiber cylinder. It is often difficult, however, to guarantee a perfect seal between the glass and carbon. Indeed, much of the time spent creating electrodes is in an effort to find a good seal. Even though epoxy resins can be useful in this regard, they are irreversible (seals are permanent), wasteful (epoxy cannot be reused once hardener is added), hazardous (hardeners are often caustic), and require curing. Herein we characterize paraffin as an electrode sealant for FSCV microelectrodes. Paraffin boasts the advantages of near-immediate curing times, simplicity in use, long shelf-life and stable waterproof seals capable of withstanding extended cycling. Borosilicate electrode tips were left intact or broken and dipped in paraffin embedding wax. Excess wax was removed from the carbon surface with xyelenes or by repeated cycling at an extended waveform (-0.4 to 1.4V, 400 V/s, 60 Hz). Then, the waveform was switched to a standard waveform (-0.4 to 1.3V, 400 V/s, 10 Hz) and cycled until stable. Wax-sealing does not inhibit electrode sensitivity, as electrodes detected linear changes in dopamine before and after wax (then xylenes) exposure. Paraffin seals are intact after 11 days of implantation in the mouse, and still capable of measuring transient changes in in vivo dopamine. From this it is clear that paraffin wax is an effective sealant for FSCV electrodes that provides a convenient substitute to epoxy sealants.

  1. Coal-tar pavement sealants might substantially increase children's PAH exposures

    USGS Publications Warehouse

    Williams, E. Spencer; Mahler, Barbara J.; Van Metre, Peter C.

    2012-01-01

    Dietary ingestion has been identified repeatedly as the primary route of human exposure to polycyclic aromatic hydrocarbons (PAHs), seven of which are classified as probable human carcinogens (B2 PAHs) by the U.S. EPA. Humans are exposed to PAHs through ingestion of cooked and uncooked foods, incidental ingestion of soil and dust, inhalation of ambient air, and absorption through skin. Although PAH sources are ubiquitous in the environment, one recently identified PAH source stands out: Coal-tar-based pavement sealant—a product applied to many parking lots, driveways, and even playgrounds primarily in the central, southern, and eastern U.S.—has PAH concentrations 100–1000 times greater than most other PAH sources. It was reported recently that PAH concentrations in house dust in residences adjacent to parking lots with coal-tar-based sealant were 25 times higher than in residences adjacent to unsealed asphalt parking lots.

  2. Hardness and modulus of elasticity of primary and permanent teeth after wear against different dental materials

    PubMed Central

    Galo, Rodrigo; Contente, Marta Maria Martins Giamatei; Galafassi, Daniel; Borsatto, Maria Cristina

    2015-01-01

    Objectives: The purpose of this study was to determine the Young's modulus and the hardness of deciduous and permanent teeth following wear challenges using different dental materials. Materials and Methods: Wear challenges were performed against four dental materials: A resin-based fissure sealant (Fluoroshield®), a glass ionomer based fissure sealant (Vitremer®), and two microhybrid composite resins (Filtek Z250 and P90®). Using the pin-on-plate design, a deciduous or a permanent tooth was made into a pin (4 mm × 4 mm × 2 mm) working at a 3 N vertical load, 1 Hz frequency, and 900 cycles (15 min) with Fusayama artificial saliva as a lubricant. Before and after the tribological tests, the hardness and elasticity modulus of the tooth samples were measured by creating a nanoindentation at load forces up to 50 mN and 150 mN. All of the results were statistically analyzed using ANOVA and post-hoc Duncan's tests (P < 0.05). Results: No difference in hardness was encountered between deciduous and permanent teeth (P < 0.05) or modulus of elasticity (P < 0.05) before or after the wear challenges for all of the dental materials tested. Conclusions: Wear challenges against the studied dental materials did not alter the properties of permanent or deciduous teeth after the application of a 3 N load. PMID:26929700

  3. Laser welding of fused silica glass with sapphire using a non- stoichiometric, fresnoitic Ba2TiSi2O8·3 SiO2 thin film as an absorber

    NASA Astrophysics Data System (ADS)

    de Pablos-Martín, A.; Lorenz, M.; Grundmann, M.; Höche, Th.

    2017-07-01

    Laser welding of dissimilar materials is challenging, due to their difference in coefficients of thermal expansion (CTE). In this work, fused silica-to-sapphire joints were achieved by employment of a ns laser focused in the intermediate Si-enriched fresnoitic glass thin film sealant. The microstructure of the bonded interphase was analyzed down to the nanometer scale and related to the laser parameters used. The crystallization of fresnoite in the glass sealant upon laser process leads to an intense blue emission intensity under UV excitation. This crystallization is favored in the interphase with the silica glass substrate, rather than in the border with the sapphire. The formation of SiO2 particles was confirmed, as well. The bond quality was evaluated by scanning acoustic microscopy (SAM). The substrates remain bonded even after heat treatment at 100 °C for 30 min, despite the large CTE difference between both substrates.

  4. Studying the Issues in Laser Joining of Lightweight Materials in a Coach-Peel Joint Configuration

    NASA Astrophysics Data System (ADS)

    Yang, Guang

    In the automotive industry, aluminum alloys have been widely used and partially replaced the conventional steel structures in order to decrease the weight of a car and improve its fuel efficiency. This Thesis focuses on the development of laser joining of light-weight materials, such as aluminum alloys and high-strength galvanized steels. Among different joint types, the coach-peel configuration is of a specific design that requires a heat source capable of heating up a large surface area of the joint. Coach-peel joints applied on the visible exterior of a car require a smooth transition from the weld surface to the panel surface and low surface roughness without any need for post-processing. Although these joints are used as non-load-bearing components, a desirable strength of the weld is also needed. A fusion-brazing process using a dual-beam laser allows the automotive components such as the roof and side member panels to be joined in a coach-peel configuration with a high surface quality as well as an acceptable strength of the weld. To improve the weld surface quality, processing parameters such as laser beam configuration, laser-wire position, and shielding gas parameters were optimized for joining of aluminum alloy to aluminum alloy. Laser power was optimized for dual-beam laser joining of aluminum alloy to galvanized steel at high speed. The feasibility of joining as-received panels with lubricant was also explored. The identification of strain hardening models of aluminum alloys was conducted for the mechanical finite element analysis of the joint. Control of the molten pool solidification through the selection of laser beam configuration is one approach to improve joint quality. Laser joining of aluminum alloy AA 6111-T4 coach peel panels with the addition of AA 4047 filler wire was investigated using three configurations of laser beam: a single beam, dual beams in-line with the weld bead, and dual beams aligned perpendicular to the weld bead (herein

  5. Pit and Fissure Sealants in Young Adults: An Evaluation of Placement Time and Retention Rate Using Two Isolation Techniques.

    DTIC Science & Technology

    1983-01-01

    retention by dental arch and method of isol..tion at twelve months ................................ 45 TABLE XVI Seven month inter-examiner reliability data...specific protection against the occurrence and progression of a specific disease, namely dental caries. The American Dental Association endorses the use...years. Yet many unanswered questions remain concerning the use of sealants. Only 15% of dental practitioners report that they routinely use them (4

  6. Strength and failure analysis of composite-to-composite adhesive bonds with different surface treatments

    NASA Astrophysics Data System (ADS)

    Paranjpe, Nikhil; Alamir, Mohammed; Alonayni, Abdullah; Asmatulu, Eylem; Rahman, Muhammad M.; Asmatulu, Ramazan

    2018-03-01

    Adhesives are widely utilized materials in aviation, automotive, energy, defense, and marine industries. Adhesive joints are gradually supplanting mechanical fasteners because they are lightweight structures, thus making the assembly lighter and easier. They also act as a sealant to prevent a structural joint from galvanic corrosion and leakages. Adhesive bonds provide high joint strength because of the fact that the load is distributed uniformly on the joint surface, while in mechanical joints, the load is concentrated at one point, thus leading to stress at that point and in turn causing joint failures. This research concentrated on the analysis of bond strength and failure loads in adhesive joint of composite-to-composite surfaces. Different durations of plasma along with the detergent cleaning were conducted on the composite surfaces prior to the adhesive applications and curing processes. The joint strength of the composites increased about 34% when the surface was plasma treated for 12 minutes. It is concluded that the combination of different surface preparations, rather than only one type of surface treatment, provides an ideal joint quality for the composites.

  7. Economic Evaluation of a School-based Combined Program with a Targeted Pit and Fissure Sealant and Fluoride Mouth Rinse in Japan.

    PubMed

    Sakuma, Shihoko; Yoshihara, Akihiro; Miyazaki, Hideo; Kobayashi, Seigo

    2010-01-01

    In Niigata prefecture, Japan, a system has been developed based on a school-based fluoride mouth rinse program as follows; students with caries susceptible teeth are screened in a school dental examination, and encouraged to receive sealant placement in local dental clinics. However, the cost-effectiveness of sealant application in the public health has been questioned. The aim of this study was to estimate of the cost-effectiveness and cost-benefit ratio for a school-based combined program with fluoride mouth rinse and targeted fissure sealant in children residing in non-fluoridated areas in Japan. The analysis was based on comparing an intervention group with two cohorts in the 8-year-old (n=66) and 11-year-old (n=58) participating in the combined program for four and seven years, respectively, with a control group of the same grades (n=43 and n=54 respectively). The study measured mean differences in number of decayed and filled teeth (DFT) between the study groups and a combined program cost per child during study periods. The cost-effectiveness ratio was expressed as an individual annual program cost per DFT averted. In the cost-benefit ratio the mean difference in treatment cost between groups (program benefit) was compared to program cost. The mean reduced DFT differences between groups were 1.44 in 8-year-old and 3.17 in 11-year-old children. The cost-effectiveness ratio was ¥ 493 in the 8-year-old and ¥ 202 in the 11-year-old, respectively. The cost-benefit ratio was 1.84 in 8-year-old children and 2.42 in 11-year-old. This combined program indicated acceptable cost-effectiveness and cost -benefit ratio.

  8. Effect of Exchanging Advancing and Retreating Side Materials on Mechanical Properties and Electrochemical Corrosion Resistance of Dissimilar 6013-T4 and 7003 Aluminum Alloys FSW Joints

    NASA Astrophysics Data System (ADS)

    Zhao, Zhixia; Liang, Haimei; Zhao, Yong; Yan, Keng

    2018-03-01

    Friction stir welding (FSW) was used to weld dissimilar joints between Al 6013-T4 and Al7003 alloys in this work. The effect of exchanging advancing (AS) and retreating (RS) side material on microstructure, mechanical behaviors and electrochemical corrosion resistance was discussed. Results showed that different joint cross sections were obtained when exchanging AS and RS materials. The material on the AS would be more deformed during the welding process. When the Al6013 placed on the AS, the plastic flow of weld is more sufficient. Whether on the AS or RS, the Al6013-T4 side is the weak region for both tensile specimens and hardness samples. The fracture position corresponds to the minimum hardness position. Also, more strengthening phase can be retained in the joint, and the joint of A6R7 has better corrosion resistance.

  9. Monomer Release from Resin Based Dental Materials Cured With LED and Halogen Lights

    PubMed Central

    Ak, Asli Topaloglu; Alpoz, A. Riza; Bayraktar, Oguz; Ertugrul, Fahinur

    2010-01-01

    Objectives: To measure the release of TEGDMA and BisGMA from two commercially available composite resins; Filtek Z 250 (3M ESPE, Germany), Leaddent (Leaddent, Germany) and two fissure sealants; Helioseal F (3M ESPE, Germany) Enamel Loc (Premiere Rev, USA) over 1, 3 and 7 days after polymerization with standard quartz-tungsten halogen Coltolux II (QHL) (Coltene Switzerland) and a standard blue light emitting diode Elipar Freelight 2 (3M ESPE, Germany). Methods: 9 samples of each material were placed in disc shaped specimens in 1 mm of thickness and 10 mm in diameter (n=36). Each material was polymerized using LED for 20 s (n=12), 40 s (n=12) and halogen for 40 s (n=12), respectively. High Performance Liquid Chromatography (HPLC) was used to measure the amount of monomers released over 1, 3 and 7 days. Data was analyzed using one way ANOVA and Bonferroni test for multiple comparisons with a significance level of .05. Results: LED 20 sec group showed the highest release of monomers at 1, 3 and 7 days in sealant groups. Halogen 40 sec group resulted highest release of monomers for Leaddent at all time intervals (P<.05) Conclusions: Efficiency of the curing unit and applying the recommended curing time of the light activated resin based dental materials is very important to protect the patient from potential hazards of residual monomers. PMID:20046478

  10. A comparison of the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts after calving in cows also given internal teat sealants.

    PubMed

    Whitfield, L K; Laven, R A

    2018-01-01

    To compare, in cows treated with an internal teat sealant, the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts (SCC) after calving. Cows from a spring-calving, pasture-based dairy farm in the Manawatu-Whanganui region of New Zealand were randomly allocated to receive either a short-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=291) or a long-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=288) at the end of lactation. Cows were managed on-farm with routine husbandry procedures through the dry period and following calving. A multivariable logistic regression model was used to determine the association between length of action of dry-cow therapy and the proportion of cows with a SCC >150,000 cells/mL at the first herd test after calving. Age of cow, mean SCC for the preceding season and interval from calving to the first post-calving herd test were all associated with the proportion of cows with an individual SCC >150,000 cells/mL at the first herd test (p<0.001) Treatment with the short-acting dry-cow therapy was not associated with decreased odds of cows having a SCC >150,000 cells/mL at the first herd test compared with treatment with long-acting dry-cow therapy (OR=0.724; 95% CI=0.40-1.30). In this herd, which routinely used internal teat sealants, the use of short-acting cloxacillin-based dry-cow therapy did not result in an increased proportion of cows with elevated SSC post-calving. This was a single farm, single year study but indicates that in this herd, changing from a long-acting to a short-acting antimicrobial may have no impact on the prevalence of subclinical mastitis.

  11. Improved bridge joint materials and design details.

    DOT National Transportation Integrated Search

    2017-06-01

    Expansion joints accommodate bridge movements that result from factors such as thermal expansion and contraction, concrete shrinkage, creep effects, live loading, settlement of the foundation and substructure, and environmental stressors. Expansion j...

  12. Strength Variation of Parachute Joints

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    A parachute joint is defined as a location where a component is sewn or connected to another component. During the design and developmental phase of a parachute system, the joints for each structural component are isolated and tested through a process called seam and joint testing. The objective of seam and joint testing is to determine the degradation on a single component due to interaction with other components; this data is then used when calculating the margin of safety for that component. During the engineering developmental phase of CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module, testing was completed for every joint of the six subsystems: the four parachutes (main, drogue, pilot, and FBCP [forward bay cover parachute]), the retention release bridle, and the retention panels. The number of joint tests for these subsystems totaled 92, which provides a plethora of data and results for further analysis. In this paper, the data and results of these seam and joint tests are examined to determine the effects, if any, of different operators and sewing machines on the strength of parachute joints. Other variables are also studied to determine their effect on joint strength, such as joint complexity, joint strength magnitude, material type, and material construction. Findings reveal that an optimally-run seam and joint test program could result in an increased understanding of the structure of the parachute; this should lead to a parachute built with optimal components, potentially saving system weight and volume.

  13. Method of forming a ceramic to ceramic joint

    DOEpatents

    Cutler, Raymond Ashton; Hutchings, Kent Neal; Kleinlein, Brian Paul; Carolan, Michael Francis

    2010-04-13

    A method of joining at least two sintered bodies to form a composite structure, includes: providing a joint material between joining surfaces of first and second sintered bodies; applying pressure from 1 kP to less than 5 MPa to provide an assembly; heating the assembly to a conforming temperature sufficient to allow the joint material to conform to the joining surfaces; and further heating the assembly to a joining temperature below a minimum sintering temperature of the first and second sintered bodies. The joint material includes organic component(s) and ceramic particles. The ceramic particles constitute 40-75 vol. % of the joint material, and include at least one element of the first and/or second sintered bodies. Composite structures produced by the method are also disclosed.

  14. A comparison of the mechanical, kinetic, and biochemical properties of fibrin clots formed with two different fibrin sealants.

    PubMed

    Hickerson, William L; Nur, Israel; Meidler, Roberto

    2011-01-01

    The objective of the present study was to compare the mechanical, kinetic, and biochemical properties of fibrin clots produced using EVICEL Fibrin Sealant (Human) and TISSEEL Fibrin Sealant. The stiffness/elasticity and strength of fibrin clots formed with EVICEL and TISSEEL were assessed using applied mechanical force and thromboelastography (TEG). The factor XIII content of the fibrin clots was also evaluated. Mean Young modulus and tensile strength of the fibrin clots produced by EVICEL were significantly higher than those of clots produced by TISSEEL (P < 0.05 for both). The mean time to initial clot formation and mean time to the predefined level of clot formation were numerically shorter for EVICEL compared with TISSEEL. Furthermore, mean maximal amplitude of the clots formed with EVICEL was significantly greater than that for the clots formed with TISSEEL. Mean concentration of factor XIII for the EVICEL fibrinogen samples tested was 9 IU/ml compared with undetectable concentrations of factor XIII for the TISSEEL fibrinogen samples. Fibrin clots formed with EVICEL have a much higher resistance to stretching and tensile strength and are more capable of maintaining their structure against applied force than those formed with TISSEEL. EVICEL also allows more rapid development of fibrin clots than TISSEEL. This superior clot strength and resilience obtained with EVICEL relative to TISSEEL may be due in large part to the presence of factor XIII.

  15. Shoulder Joint For Protective Suit

    NASA Technical Reports Server (NTRS)

    Kosmo, Joseph J.; Smallcombe, Richard D.

    1994-01-01

    Shoulder joint allows full range of natural motion: wearer senses little or no resisting force or torque. Developed for space suit, joint offers advantages in protective garments for underwater work, firefighting, or cleanup of hazardous materials.

  16. Topical anesthesia for rubber dam clamp placement in sealant placement: comparison of lidocaine/prilocaine gel and benzocaine.

    PubMed

    Yoon, Richard K; Chussid, Steven

    2009-01-01

    The purpose of this prospective study was to compare the efficacy of Oraqix to benzocaine while placing a rubber dam clamp during sealant placement on children. A sample size of 45 7- to 12-year-old patients who presented for bilateral sealants on permanent first molars participated in this study. A split-mouth design was implemented with Oraqix applied to one side and 20 percent benzocaine gel applied to the other. After placing the topical anesthetic and the rubber dam clamp, patients completed a Feces Pain Scale (FPS) to rate the level of discomfort after clamp placement. Twenty-seven subjects (60%) were female and 18 subjects (40%) were mole; 15 (33%) were younger than 9 years old and 30 (67%) were at least 9 years old. The overall difference in mean FPS ratings was not statistically significant (P = .27). Regarding gender, there was no statistically significant difference in males (P = .65) or females (P = .26). There was also no difference in mean FPS ratings when looking at age groups younger than 9 years old with P=.77 In the 9 years and older age groups, however there was a statistically significant difference, with P = .04. Application of Oraqix did not reduce discomfort when compared to benzocaine in this small sample size. Oraqix was more effective than benzocaine in the age group 9 and older. A larger sample size is needed to determine its efficacy in children younger than 9years old.

  17. 78 FR 27953 - Notification of Proposed Production Activity, CNH America, LLC, Subzone 59B, (Agricultural...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ....14(b), FTZ activity would be limited to the specific foreign-status materials and components and... housings; vertical auger tubes; chopper drive gearbox accessories; cotton picker frames and cabs; and, non... components and materials sourced from abroad include: sealant; sealant paste; oil drain assemblies; rubber...

  18. Viscous sealing glass compositions for solid oxide fuel cells

    DOEpatents

    Kim, Cheol Woon; Brow, Richard K.

    2016-12-27

    A sealant for forming a seal between at least two solid oxide fuel cell components wherein the sealant comprises a glass material comprising B.sub.2O.sub.3 as a principal glass former, BaO, and other components and wherein the glass material is substantially alkali-free and contains less than 30% crystalline material.

  19. Smart material joint band

    NASA Astrophysics Data System (ADS)

    Tucchio, Michael A.; Stoodt, Robert A.; Livsey, Robert A.

    1994-11-01

    The present invention relates to an improved connector for joining two tubular members together. The connector is formed by a plurality of longitudinally extending fingers extending from an end of one of tubular members and at least one locking groove in the other of the tubular members for receiving the fingers. The connector further includes a circumferentially extending wire member which is received in a notch in a head portion of each of the plurality of fingers. The wire member is preferably formed from a shape memory alloy and has an original circumference less than the circumference of a circle formed by the notches in a head portions of the fingers. The connector includes apertures through which electric wires may be connected to the shape memory alloy ring member so as to cause the shape memory alloy ring member to return to its original shape and allow release of the joint connection.

  20. Smart material joint band

    NASA Astrophysics Data System (ADS)

    Tucchio, Michael A.; Stoodt, Robert A.; Livsey, Robert A.

    1993-12-01

    The present invention relates to an improved connector for joining two tubular members together. The connector is formed by a plurality of longitudinally extending fingers extending from an end of one of the tubular members and at least one locking groove in the other of the tubular members for receiving the fingers. The connector further includes a circumferentially extending wire member which is received in a notch in a head portion of each of the plurality of fingers. The wire member is preferably formed from a shape memory alloy and has an original circumference less than the circumference of a circle formed by the notches in the head portions of the fingers. The connector includes apertures through which electric wires may be connected to the shape memory alloy ring member so as to cause the shape memory alloy ring member to return to its original shape and allow release of the joint connection.

  1. Strength and Mechanics of Bonded Scarf Joints for Repair of Composite Materials

    NASA Technical Reports Server (NTRS)

    Pipes, R. B.; Adkins, D. W.

    1982-01-01

    Experimental and analytical investigations of scarf joints indicate that slight bluntness of adherend tips induces adhesive stress concentrations which significantly reduce joint strength, and the stress distribution through the adhesive thickness is non-uniform and has significant stress concentrations at the ends of the joint. The laminate stacking sequence can have important effects on the adhesive stress distribution. A significant improvement in joint strength is possible by increasing overlap at the expense of raising the repair slightly above the original surface. Although a surface grinder was used to make most experimental specimens, a hand held rotary bur can make a surprisingly good scarf. Scarf joints wit doublers on one side, such as might be used for repair, bend under tensile loads and may actually be weaker than joints without doublers.

  2. Structural analysis of Aircraft fuselage splice joint

    NASA Astrophysics Data System (ADS)

    Udaya Prakash, R.; Kumar, G. Raj; Vijayanandh, R.; Senthil Kumar, M.; Ramganesh, T.

    2016-09-01

    In Aviation sector, composite materials and its application to each component are one of the prime factors of consideration due to the high strength to weight ratio, design flexibility and non-corrosive so that the composite materials are widely used in the low weight constructions and also it can be treated as a suitable alternative to metals. The objective of this paper is to estimate and compare the suitability of a composite skin joint in an aircraft fuselage with different joints by simulating the displacement, normal stress, vonmises stress and shear stress with the help of numerical solution methods. The reference Z-stringer component of this paper is modeled by CATIA and numerical simulation is carried out by ANSYS has been used for splice joint presents in the aircraft fuselage with three combinations of joints such as riveted joint, bonded joint and hybrid joint. Nowadays the stringers are using to avoid buckling of fuselage skin, it has joined together by rivets and they are connected end to end by splice joint. Design and static analysis of three-dimensional models of joints such as bonded, riveted and hybrid are carried out and results are compared.

  3. Study of simple CFRP-metal joint failure

    NASA Astrophysics Data System (ADS)

    Cheng, Jingquan; Rodriguez, Antonio; Emerson, Nicolas; Symmes, Arthur

    2008-07-01

    In millimeter wavelength telescope design and construction, there have been a number of mysterious failures of simple CFRF-metal joints. Telescope designers have not had satisfactory interpretations of these failures. In this paper, factors which may influence the failure of joints are discussed. These include stress concentration, material creep, joint fatigue, reasons related to chemical process and manufacture process. Extrapolation formulas for material creep, joint fatigue, and differential thermal stresses are derived in this paper. Detailed chemical and manufacturing factors are also discussed. All these issues are the causes of a number of early failures under a loading which is significantly lower than the strength of adhesives used. For ensuring reliability of a precision instrument structure joint, the designer should have a thorough understanding of all these factors.

  4. The effect of pit and fissure sealants on the detection of occlusal caries in vitro.

    PubMed

    Manton, D J; Messer, L B

    2007-03-01

    To compare, in vitro, the effect of placing opaque (OPS) and clear fluorescing (CFS) pit and fissure sealants (PFS) on the detection of occlusal caries (OCD). Occlusal surfaces of 67 extracted molars were examined under standardised conditions by 6 final year undergraduate dental students, using visual, bitewing radiography, transillumination (FOTI), laser fluorescence (LF) and tactile methods of caries detection. The teeth were then assigned randomly to two groups for PFS placement: OPS and CFS; then the OCD methods were repeated. Caries presence/absence was determined histologically on serial sections examined under stereo-microscopy (10x). Before PFS placement the sensitivity and specificity for the OCD methods were: visual: 68%, 71%; radiographic: 15%, 95%; FOTI: 36%, 93%; LF: 49%, 83% and tactile: 39%, 67%, respectively. After placement of OPS, the sensitivity of LF (20%) and visual (13%) methods decreased and specificity increased (93%, 98% respectively). Placement of CFS resulted in minor changes in sensitivity and specificity. Correlation (Spearman's Rho coefficients) between OCD methods and histological intra-dentinal caries for pre- PFS, OPS, and CFS were: visual: 0.38, 0.34, 0.33; FOTI: 0.42, 0.35, 0.43; and LF: 0.41, 0.30, and 0.45 respectively. The sensitivity of all OCD methods was low, as well as their correlation to the histological gold standard. Placing OPS further decreased the sensitivity of LF and visual methods, whereas placing CFS had little effect on all OCD methods. It is recommended that tactile detection of occlusal caries should be discontinued, and the probe used only to clean the pits and fissures gently for more accurate visual detection, or prior to pit and fissure sealant placement. Further research into the development of an affordable, robust, accurate and easy to use method for OCD is required.

  5. The new heterologous fibrin sealant in combination with low-level laser therapy (LLLT) in the repair of the buccal branch of the facial nerve.

    PubMed

    Buchaim, Daniela Vieira; Rodrigues, Antonio de Castro; Buchaim, Rogerio Leone; Barraviera, Benedito; Junior, Rui Seabra Ferreira; Junior, Geraldo Marco Rosa; Bueno, Cleuber Rodrigo de Souza; Roque, Domingos Donizeti; Dias, Daniel Ventura; Dare, Leticia Rossi; Andreo, Jesus Carlos

    2016-07-01

    This study aimed to evaluate the effects of low-level laser therapy (LLLT) in the repair of the buccal branch of the facial nerve with two surgical techniques: end-to-end epineural suture and coaptation with heterologous fibrin sealant. Forty-two male Wistar rats were randomly divided into five groups: control group (CG) in which the buccal branch of the facial nerve was collected without injury; (2) experimental group with suture (EGS) and experimental group with fibrin (EGF): The buccal branch of the facial nerve was transected on both sides of the face. End-to-end suture was performed on the right side and fibrin sealant on the left side; (3) Experimental group with suture and laser (EGSL) and experimental group with fibrin and laser (EGFL). All animals underwent the same surgical procedures in the EGS and EGF groups, in combination with the application of LLLT (wavelength of 830 nm, 30 mW optical power output of potency, and energy density of 6 J/cm(2)). The animals of the five groups were euthanized at 5 weeks post-surgery and 10 weeks post-surgery. Axonal sprouting was observed in the distal stump of the facial nerve in all experimental groups. The observed morphology was similar to the fibers of the control group, with a predominance of myelinated fibers. In the final period of the experiment, the EGSL presented the closest results to the CG, in all variables measured, except in the axon area. Both surgical techniques analyzed were effective in the treatment of peripheral nerve injuries, where the use of fibrin sealant allowed the manipulation of the nerve stumps without trauma. LLLT exhibited satisfactory results on facial nerve regeneration, being therefore a useful technique to stimulate axonal regeneration process.

  6. Mechanics of Suture Joints

    NASA Astrophysics Data System (ADS)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  7. Effect of Nd:YAG laser beam welding on weld morphology and mechanical properties of Ti-6Al-4V butt joints and T-joints

    NASA Astrophysics Data System (ADS)

    Kashaev, Nikolai; Ventzke, Volker; Fomichev, Vadim; Fomin, Fedor; Riekehr, Stefan

    2016-11-01

    A Nd:YAG single-sided laser beam welding process study for Ti-6Al-4V butt joints and T-joints was performed to investigate joining techniques with regard to the process-weld morphology relationship. An alloy compatible filler wire was used to avoid underfills and undercuts. The quality of the butt joints and T-joints was characterized in terms of weld morphology, microstructure and mechanical properties. Joints with regular shapes, without visible cracks, pores, and geometrical defects were achieved. Tensile tests revealed high joint integrity in terms of strength and ductility for both the butt joint and T-joint geometries. Both the butt joints and T-joints showed base material levels of strength. The mechanical performance of T-joints was also investigated using pull-out tests. The performance of the T-joints in such tests was sensitive to the shape and morphology of the welds. Fracture always occurred in the weld without any plastic deformation in the base material outside the weld.

  8. 49 CFR 195.216 - Welding: Miter joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding: Miter joints. 195.216 Section 195.216 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.216 Welding: Miter joints. A miter joint is not permitted (not including...

  9. 49 CFR 195.216 - Welding: Miter joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Welding: Miter joints. 195.216 Section 195.216 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.216 Welding: Miter joints. A miter joint is not permitted (not including...

  10. 49 CFR 195.216 - Welding: Miter joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Welding: Miter joints. 195.216 Section 195.216 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.216 Welding: Miter joints. A miter joint is not permitted (not including...

  11. 49 CFR 195.216 - Welding: Miter joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Welding: Miter joints. 195.216 Section 195.216 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.216 Welding: Miter joints. A miter joint is not permitted (not including...

  12. 49 CFR 195.216 - Welding: Miter joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Welding: Miter joints. 195.216 Section 195.216 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.216 Welding: Miter joints. A miter joint is not permitted (not including...

  13. Requirements for Weatherproofing Thin Shell Concrete Roofs. Proceedings of the Conference of Building Research Institute, Division of Engineering and Industrial Research (Spring 1961).

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC.

    Topics discussed include--(1) requirements for weatherproofing and sealant materials for thin shell concrete roof, (2) effect of physical factors on weatherproofing of thin shell concrete roofs, (3) problems and limitations imposed by thin shell concrete roofs and their effect on weatherproofing and sealant materials, and (4) properties and uses…

  14. Corrosion Mitigation and Materials Selection Guide for Military Construction in a Severely Corrosive Environment

    DTIC Science & Technology

    1988-07-01

    Skylights 33 OGS Section No. 07840: Ventilators, Roof: Gravity Type 33 SOGS Section No. 07951: Calking and Sealants 34 4 CONTENTS (Cont’d) Page 7 DOORS...shall be fully bonded to the primed surface. The finished surface shall be smooth, lustrous, and impervious to moisture. Dull or porous spots shall be...Type 1 21, Type I Gloss, TT-P-645 TT-E-1593 TT-E-1593 Sunlight Resistant SOGS Section No. 07810: Skylights Environment - Exposure Materials Selection

  15. Literature Review on the Design of Composite Mechanically Fastened Joints (Revue de la Documentation sur la Conception des Joints a Liaison Mecanique en Composites),

    DTIC Science & Technology

    1986-02-01

    mechanics Eisenmann (32) established a bolted joint static strength prediction model based on fracture mechanics for composite materials. The failure...34 Composite Materials, Volume 2, Academic Press, 1974, pp. 353-431. 32. Eisenmann , J.R., "Bolted Joint Static Strength Model for Composite Materials," NASA

  16. An in vitro study of fibrin sealant as a carrier system for recombinant human bone morphogenetic protein (rhBMP)-9 for bone tissue engineering.

    PubMed

    Fujioka-Kobayashi, Masako; Mottini, Matthias; Kobayashi, Eizaburo; Zhang, Yufeng; Schaller, Benoit; Miron, Richard J

    2017-01-01

    In the craniofacial bone field, fibrin sealants are used as coagulant and adhesive tools to stabilize grafts during surgery. Despite this, their exact role in osteogenesis is poorly characterized. In the present study, we aimed to characterize the osteogenic potential of TISSEEL fibrin sealant and used its technology to incorporate growth factors within its matrix. We focused on recombinant human bone morphogenetic protein (rhBMP)-9, which has previously been characterized as one of the strongest osteogenetic inducers in the BMP family. TISSEEL displayed an excellent ability to retain rhBMP9, which was gradually released over a 10-day period. Although TISSEEL decreased bone stromal ST2 cell attachment at 8 h, it displayed normal cell proliferation at 1, 3, and 5 days when compared to tissue culture plastic. Interestingly, TISSEEL had little influence on osteoblast differentiation; however its combination with rhBMP9 significantly increased ALP activity at 7 days, Alizarin Red staining at 14 days, and mRNA levels of osteoblast differentiation markers ALP, bone sialoprotein, and osteocalcin. In summary, although fibrin sealants were shown to have little influence on osteogenesis, their combination with bone-inducing growth factors such as rhBMP9 may serve as an attractive carrier/scaffold for future bone regenerative strategies. Future animal studies are now necessary. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. A thermomechanical anisotropic model for shock loading of elastic-plastic and elastic-viscoplastic materials with application to jointed rock

    DOE PAGES

    Rubin, M. B.; Vorobiev, O.; Vitali, E.

    2016-04-21

    Here, a large deformation thermomechanical model is developed for shock loading of a material that can exhibit elastic and inelastic anisotropy. Use is made of evolution equations for a triad of microstructural vectors m i(i=1,2,3) which model elastic deformations and directions of anisotropy. Specific constitutive equations are presented for a material with orthotropic elastic response. The rate of inelasticity depends on an orthotropic yield function that can be used to model weak fault planes with failure in shear and which exhibits a smooth transition to isotropic response at high compression. Moreover, a robust, strongly objective numerical algorithm is proposed formore » both rate-independent and rate-dependent response. The predictions of the continuum model are examined by comparison with exact steady-state solutions. Also, the constitutive equations are used to obtain a simplified continuum model of jointed rock which is compared with high fidelity numerical solutions that model a persistent system of joints explicitly in the rock medium.« less

  18. Intradiscal injection of fibrin sealant for the treatment of symptomatic lumbar internal disc disruption: results of a prospective multicenter pilot study with 24-month follow-up.

    PubMed

    Yin, Way; Pauza, Kevin; Olan, Wayne J; Doerzbacher, Jeff F; Thorne, Kevin J

    2014-01-01

    Assess the safety and efficacy of intradiscal fibrin sealant in adults with chronic discogenic low back pain. Prospective, nonrandomized Food and Drug Administration approved pilot study. Three centers in the United States. Fifteen adults with chronic, single, or contiguous two-level lumbar discogenic pain confirmed through meticulous provocation discography. Volume- and pressure-controlled intradiscal delivery of BIOSTAT BIOLOGX(®) Fibrin Sealant with the Biostat(®) Delivery Device into symptomatic lumbar disc(s). Assessments were performed at baseline, 72 hours, and 1, 4, 13, 26, 52, and 104 weeks following intervention. Potential adverse events were evaluated with serial assessment of neurological status, radiographic, and magnetic resonance imaging (MRI). Efficacy measures included serial assessments of low back pain visual analog scale (VAS) measurements and the Roland-Morris Disability Questionnaire (RMDQ). Safety neurological assessments, X-ray, and MRI showed no significant changes. Adverse events were reported in nine subjects. Two instances of low back muscle spasm and one case of discitis were the only events considered related to the procedure or product. Mean low back pain VAS scores (mm) decreased from 72.4 (95% confidence interval 64.6-80.3) at baseline to 31.7 (17.4-46.1), 35.4 (17.7-53.1), and 33.0 (16.3-49.6); mean RMDQ score improved from 15.2 (12.7-17.7) at baseline to 8.9 (5.3-12.5), 6.2 (3.4-9.1), and 5.6 (2.9-8.4) at 26, 52, and 104 weeks, respectively. Intradiscal injection of BIOSTAT BIOLOGX Fibrin Sealant with the Biostat Delivery Device appears safe and may improve pain and function in selected patients with discogenic pain. Wiley Periodicals, Inc.

  19. Common Bolted Joint Analysis Tool

    NASA Technical Reports Server (NTRS)

    Imtiaz, Kauser

    2011-01-01

    Common Bolted Joint Analysis Tool (comBAT) is an Excel/VB-based bolted joint analysis/optimization program that lays out a systematic foundation for an inexperienced or seasoned analyst to determine fastener size, material, and assembly torque for a given design. Analysts are able to perform numerous what-if scenarios within minutes to arrive at an optimal solution. The program evaluates input design parameters, performs joint assembly checks, and steps through numerous calculations to arrive at several key margins of safety for each member in a joint. It also checks for joint gapping, provides fatigue calculations, and generates joint diagrams for a visual reference. Optimum fastener size and material, as well as correct torque, can then be provided. Analysis methodology, equations, and guidelines are provided throughout the solution sequence so that this program does not become a "black box:" for the analyst. There are built-in databases that reduce the legwork required by the analyst. Each step is clearly identified and results are provided in number format, as well as color-coded spelled-out words to draw user attention. The three key features of the software are robust technical content, innovative and user friendly I/O, and a large database. The program addresses every aspect of bolted joint analysis and proves to be an instructional tool at the same time. It saves analysis time, has intelligent messaging features, and catches operator errors in real time.

  20. Low-temperature resistant, elastic adhesives and sealants for gas tank insulation

    NASA Astrophysics Data System (ADS)

    Karrer, R.

    The leading European insulating firms in the domain of liquid natural gas (LNG)/liquid petroleum gas (LPG) carriers have developed special sandwich elements for the insulation of liquid gas tanks. The trend to increasing tank volumes and, at the same time, to reducing the number of cargo tanks in modern liquid gas carriers with loading capacities of up to 135,000 m 3 has in some cases entailed major changes with respect to tank design (Kaefer-Isoliertechnik, Hansa Schiffahrt-Schiffbau-Hafen, 133rd year, 1996, 2, 20-22). These changes have equally influenced both the design and the assembly of the panels used for insulation, as well as the adhesives and sealants applied for this purpose. This article describes the requirement profile and the possible applications of solvent-free two-component polyurethane adhesives (2-K PU) and recently developed polyurethane hot-melt adhesives (PU-HM) for the manufacture and/or assembly of panels. Moreover, it deals with the role of the advanced solvent-free, silane-modified polymers (MS polymers) in the pointing of panels (seam-sealing) exposed to low temperatures.

  1. Sealants and cold regions pavement seals : a review

    DOT National Transportation Integrated Search

    1995-05-01

    A pavement joint seal prevents the passage of liquids into the pavement base and the intrusion of solids into the joint. The primary mechanical requirements of a pavement seal are that it respond elastically or viscoelastically to any movement of the...

  2. Interactions between F-111 Fuselage Fuel Tank Sealants. Part 2. Variation in Performance Properties of Polysulfides after Contact with Polyester Degradation Products,

    DTIC Science & Technology

    1984-08-01

    principally from sebacic acid and neopentyl glycol and that the most significant difference between the sealants was the greater proportion of trihydric...exhaustive hydrolysis of the polyesters would generate sebacic acid and neopentyl glycol , in practice ester units such as (1) which are terminated with both...slight to moderate swelling and softening of the polysulfides with PR-1422 being the most susceptible. Neopentyl glycol suppressed the swelling due to

  3. Adhesive Bonding Characterization of Composite Joints for Cryogenic Usage

    NASA Technical Reports Server (NTRS)

    Graf, Neil A.; Schieleit, Gregory F.; Biggs, Robert

    2000-01-01

    The development of polymer composite cryogenic tanks is a critical step in creating the next generation of launch vehicles. Future reusable launch vehicles need to minimize the gross liftoff weight (GLOW). This weight reduction is possible due to the large reduction in weight that composite materials can provide over current aluminum technology. In addition to composite technology, adhesively bonded joints potentially have several benefits over mechanically fastened joints, such as weight savings and cryogenic fluid containment. Adhesively bonded joints may be used in several areas of these cryogenic tanks, such as in lobe-to-lobe joints (in a multi-lobe concept), skirt-to-tank joint, strut-to-tank joint, and for attaching stringers and ring frames. The bonds, and the tanks themselves, must be able to withstand liquid cryogenic fuel temperatures that they contain. However, the use of adhesively bonded composite joints at liquid oxygen and hydrogen temperatures is largely unknown and must be characterized. Lockheed Martin Space Systems Company, Michoud Operations performed coupon-level tests to determine effects of material selection, cure process parameters, substrate surface preparation, and other factors on the strength of these composite joints at cryogenic temperatures. This led to the selection of a material and process that would be suitable for a cryogenic tank. KEY WORDS: Composites, Adhesive Bonding, Cryogenics

  4. A Rapid Survey of the Compatibility of Selected Seal Materials with Conventional and Semi-Synthetic JP-8

    NASA Technical Reports Server (NTRS)

    Graham, John L.; Striebich, Richard C.; Minus, Donald K.; Harrison, William E., III

    2007-01-01

    Since the synthesis of a liquid hydrocarbon fuel from coal by Franz Fischer and Hans Tropsch in 1923, there has been cyclic interest in developing this fuel for military and commercial applications. In recent years the U.S. Department of Defense has taken interest in producing a unified battlespace fuel using the Fischer Tropsch (FT) process for a variety of reasons including cost, quality, and logistics. In the past year there has been a particular emphasis on moving quickly to demonstrate that an FT fuel can be used in the form of a blend with conventional petroleum-derived jet fuel. The initial objective is to employ this semi-synthetic fuel with blend ratios as high as 50 percent FT with longer range goals to use even high blend ratios and ultimately a fully synthetic jet fuel. A significant concern associated with the use of a semi-synthetic jet fuel with high FT blend ratios is the effect these low aromatic fuels will have on fuel-wetted polymeric materials, most notably seals and sealants. These materials typically swell and soften to some degree when exposed to jet fuel and the aromatic content of these fuels contribute to this effect. Semi-synthetic jet fuels with very low aromatic contents may cause seals and sealants to shrink and harden leading to acute or chronic failure. Unfortunately, most of the material qualification tests are more concerned with excessive swelling than shrinkage and there is little guidance offered as to an acceptable level of shrinkage or other changes in physical properties related to low aromatic content. Given the pressing need for guidance data, a program was developed to rapidly survey the volume swell of selected fuel-wetted materials in a range of conventional and semi-synthetic jet fuels and through a statistical analysis to make a determination as to whether there was a basis to be concerned about using fuels with FT blend ratios as high as 50 percent. Concurrent with this analysis data was obtained as to the composition

  5. The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.

    2012-01-01

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various

  6. Surface Modifications for Improved Wear Performance in Artificial Joints: A Review

    NASA Astrophysics Data System (ADS)

    Sullivan, Stacey J. L.; Topoleski, L. D. Timmie

    2015-11-01

    Artificial joint replacement is one of the most successful treatments for arthritis. Excellent wear and corrosion resistance, together with high strength and fracture toughness, are fundamental requirements for implant materials. Wear and/or corrosion of the materials used in artificial joints may lead to implant failure. Therefore, hard and wear-resistant materials, like cobalt-chromium-molybdenum and ceramic, are currently used as bearing surfaces. However, even using such hard materials, wear and/or corrosion related failure of artificial joints remains a central concern. One primary goal in orthopedic biomaterials research is to create more wear-resistant surfaces. Different technologies have been used to create new surfaces, or to modify existing surfaces, to prevent wear. It is the intent of this overview first to provide a summary of materials currently used as bearing surfaces in artificial joints, their functions, and their contributions to device longevity. Then, we will discuss advancements in modifying those bearing surfaces to produce more wear-resistant artificial joints.

  7. Fatigue properties of dissimilar metal laser welded lap joints

    NASA Astrophysics Data System (ADS)

    Dinsley, Christopher Paul

    This work involves laser welding austenitic and duplex stainless steel to zinc-coated mild steel, more specifically 1.2mm V1437, which is a Volvo Truck Coiporation rephosphorised mild steel. The work investigates both tensile and lap shear properties of similar and dissimilar metal laser welded butt and lap joints, with the majority of the investigation concentrating on the fatigue properties of dissimilar metal laser welded lap joints. The problems encountered when laser welding zinc-coated steel are addressed and overcome with regard to dissimilar metal lap joints with stainless steel. The result being the production of a set of guidelines for laser welding stainless steel to zinc-coated mild steel. The stages of laser welded lap joint fatigue life are defined and the factors affecting dissimilar metal laser welded lap joint fatigue properties are analysed and determined; the findings suggesting that dissimilar metal lap joint fatigue properties are primarily controlled by the local stress at the internal lap face and the early crack growth rate of the material at the internal lap face. The lap joint rotation, in turn, is controlled by sheet thickness, weld width and interfacial gap. Laser welded lap joint fatigue properties are found to be independent of base material properties, allowing dissimilar metal lap joints to be produced without fatigue failure occurring preferentially in the weaker parent material, irrespective of large base material property differences. The effects of Marangoni flow on the compositions of the laser weld beads are experimentally characterised. The results providing definite proof of the stirring mechanism within the weld pool through the use of speeds maps for chromium and nickel. Keywords: Laser welding, dissimilar metal, Zinc-coated mild steel, Austenitic stainless steel, Duplex stainless steel, Fatigue, Lap joint rotation, Automotive.

  8. On the Process-Related Rivet Microstructural Evolution, Material Flow and Mechanical Properties of Ti-6Al-4V/GFRP Friction-Riveted Joints.

    PubMed

    Borba, Natascha Z; Afonso, Conrado R M; Blaga, Lucian; Dos Santos, Jorge F; Canto, Leonardo B; Amancio-Filho, Sergio T

    2017-02-15

    In the current work, process-related thermo-mechanical changes in the rivet microstructure, joint local and global mechanical properties, and their correlation with the rivet plastic deformation regime were investigated for Ti-6Al-4V (rivet) and glass-fiber-reinforced polyester (GF-P) friction-riveted joints of a single polymeric base plate. Joints displaying similar quasi-static mechanical performance to conventional bolted joints were selected for detailed characterization. The mechanical performance was assessed on lap shear specimens, whereby the friction-riveted joints were connected with AA2198 gussets. Two levels of energy input were used, resulting in process temperatures varying from 460 ± 130 °C to 758 ± 56 °C and fast cooling rates (178 ± 15 °C/s, 59 ± 15 °C/s). A complex final microstructure was identified in the rivet. Whereas equiaxial α-grains with β-phase precipitated in their grain boundaries were identified in the rivet heat-affected zone, refined α' martensite, Widmanstätten structures and β-fleck domains were present in the plastically deformed rivet volume. The transition from equiaxed to acicular structures resulted in an increase of up to 24% in microhardness in comparison to the base material. A study on the rivet material flow through microtexture of the α-Ti phase and β-fleck orientation revealed a strong effect of shear stress and forging which induced simple shear deformation. By combining advanced microstructural analysis techniques with local mechanical testing and temperature measurement, the nature of the complex rivet plastic deformational regime could be determined.

  9. On the Process-Related Rivet Microstructural Evolution, Material Flow and Mechanical Properties of Ti-6Al-4V/GFRP Friction-Riveted Joints

    PubMed Central

    Borba, Natascha Z.; Afonso, Conrado R. M.; Blaga, Lucian; dos Santos, Jorge F.; Canto, Leonardo B.; Amancio-Filho, Sergio T.

    2017-01-01

    In the current work, process-related thermo-mechanical changes in the rivet microstructure, joint local and global mechanical properties, and their correlation with the rivet plastic deformation regime were investigated for Ti-6Al-4V (rivet) and glass-fiber-reinforced polyester (GF-P) friction-riveted joints of a single polymeric base plate. Joints displaying similar quasi-static mechanical performance to conventional bolted joints were selected for detailed characterization. The mechanical performance was assessed on lap shear specimens, whereby the friction-riveted joints were connected with AA2198 gussets. Two levels of energy input were used, resulting in process temperatures varying from 460 ± 130 °C to 758 ± 56 °C and fast cooling rates (178 ± 15 °C/s, 59 ± 15 °C/s). A complex final microstructure was identified in the rivet. Whereas equiaxial α-grains with β-phase precipitated in their grain boundaries were identified in the rivet heat-affected zone, refined α′ martensite, Widmanstätten structures and β-fleck domains were present in the plastically deformed rivet volume. The transition from equiaxed to acicular structures resulted in an increase of up to 24% in microhardness in comparison to the base material. A study on the rivet material flow through microtexture of the α-Ti phase and β-fleck orientation revealed a strong effect of shear stress and forging which induced simple shear deformation. By combining advanced microstructural analysis techniques with local mechanical testing and temperature measurement, the nature of the complex rivet plastic deformational regime could be determined. PMID:28772545

  10. Early experience of the use of fibrin sealant in the management of children with pilonidal sinus disease.

    PubMed

    Smith, Caroline Mary; Jones, Abigail; Dass, Dipankar; Murthi, Govind; Lindley, Richard

    2015-02-01

    The use of fibrin sealant in the management of pilonidal sinus disease has not previously been described in children. We present our experience of primary pit excision and use of fibrin sealant (PEF) and compare outcomes with lateralising flap procedures (LFP). A single centre retrospective case note review of all children who had undergone a definitive procedure for pilonidal sinus from August 2006 to Dec 2013 was performed using data expressed as median (range) and compared using Fisher's exact test. P<0.05 was regarded as significant. Forty-one children were identified having undergone 49 procedures, with median age 15 (12-16 years) and follow up 32 (8-92) months. Groups were comparable for disease severity. Ten children underwent primary PEF and twenty-six LFP. Two children had recurrence following primary PEF and had repeat PEF which was curative. Overall recurrence rates following PEF procedure were comparable to LFP (17% vs 21%; P=1.0). There were no wound dehiscences in the PEF group and one wound infection. There was one wound dehiscence and one wound infection in the LFP group. Median operative time for PEF was lower than LFP (20 vs 60 min, P=0.001). 83% of PEF procedures were performed as day cases. One child was lost to follow up, and two children progressed to adult services. We recommend PEF in children with pilonidal sinus disease as primary treatment and for recurrence. PEF has comparable recurrence and wound infection rates to LFPs, is performed as day case, has shorter anaesthetic times, and the risk of wound dehiscence is avoided. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Accuracy of acromioclavicular joint injections.

    PubMed

    Wasserman, Bradley R; Pettrone, Sarah; Jazrawi, Laith M; Zuckerman, Joseph D; Rokito, Andrew S

    2013-01-01

    Injection to the acromioclavicular (AC) joint can be both diagnostic and therapeutic. The purpose of this study was to evaluate the accuracy of in vivo AC joint injections. Case series; Level of evidence, 4. Thirty patients with pain localized to the AC joint were injected with 1 mL of 1% lidocaine and 0.5 mL of radiographic contrast material (Isovue). Radiographs of the AC joint were taken after the injection. Each radiograph was reviewed by a musculoskeletal radiologist and graded as intra-articular, extra-articular, or partially intra-articular. Of the 30 injections performed, 13 (43.3%) were intra-articular, 7 (23.3%) were partially articular, and 10 (33.3%) were extra-articular. When the intra-articular and the partially articular groups were combined, 20 patients (66.7%) had some contrast dye in the AC joint. This study demonstrates that despite the relatively superficial location of the AC joint, the clinical accuracy of AC joint injections remains relatively low.

  12. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    PubMed

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  13. High pressure ceramic joint

    DOEpatents

    Ward, Michael E.; Harkins, Bruce D.

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  14. Stability of Beriplast P fibrin sealant: storage and reconstitution.

    PubMed

    Eberhard, Ulrich; Broder, Martin; Witzke, Günther

    2006-04-26

    This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.

  15. Influence of clamp-up force on the strength of bolted composite joints

    NASA Astrophysics Data System (ADS)

    Horn, Walter J.; Schmitt, Ron R.

    1994-03-01

    Composite materials offer the potential for a reduction in the number of individual parts and joints in a structure because large one-piece components can replace multipart assemblies. Nevertheless, there are many situations where composite parts must be joined and often mechanical fasteners provide the only practical method of joining those parts. The long-term strength of mechanically fastened joints of composite members can be directly affected by the clamp-up force of the fastener and thus perhaps by the relaxation of this force due to the viscoelastic character of the composite materials of the joint. Methods for predicting the effect of bolt clamp-up force relaxation on the strength of mechanically fastened joints of thermoplastic composite materials were investigated during the present study. A test program, using two thermoplastic composite materials, was conducted to determine the influence of clamp-up force on joint strength, to measure the relaxation of the joint clamp-up force with time, and to measure the change of joint strength as a function of time.

  16. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    NASA Astrophysics Data System (ADS)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  17. Computer simulation of solder joint failure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burchett, S.N.; Frear, D.R.; Rashid, M.M.

    The thermomechanical fatigue failure of solder joints is increasingly becoming an important reliability issue for electronic packages. The purpose of this Laboratory Directed Research and Development (LDRD) project was to develop computational tools for simulating the behavior of solder joints under strain and temperature cycling, taking into account the microstructural heterogeneities that exist in as-solidified near eutectic Sn-Pb joints, as well as subsequent microstructural evolution. The authors present two computational constitutive models, a two-phase model and a single-phase model, that were developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions. Unique metallurgical tests provide themore » fundamental input for the constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations with this model agree qualitatively with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. The single-phase model was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. Special thermomechanical fatigue tests were developed to give fundamental materials input to the models, and an in situ SEM thermomechanical fatigue test system was developed to characterize microstructural evolution and the mechanical behavior of solder joints during the test. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests. The simulation results from the two-phase model showed good fit to the experimental test results.« less

  18. Microstructure and Mechanical Properties of Reaction-Formed Joints in Reaction Bonded Silicon Carbide Ceramics

    NASA Technical Reports Server (NTRS)

    Singh, M.

    1998-01-01

    A reaction-bonded silicon carbide (RB-SiC) ceramic material (Carborundum's Cerastar RB-SIC) has been joined using a reaction forming approach. Microstructure and mechanical properties of three types of reaction-formed joints (350 micron, 50-55 micron, and 20-25 micron thick) have been evaluated. Thick (approximately 350 micron) joints consist mainly of silicon with a small amount of silicon carbide. The flexural strength of thick joints is about 44 plus or minus 2 MPa, and fracture always occurs at the joints. The microscopic examination of fracture surfaces of specimens with thick joints tested at room temperature revealed the failure mode to be typically brittle. Thin joints (<50-55 micron) consist of silicon carbide and silicon phases. The room and high temperature flexural strengths of thin (<50-55 micron) reaction-formed joints have been found to be at least equal to that of the bulk Cerastar RB-SIC materials because the flexure bars fracture away from the joint regions. In this case, the fracture origins appear to be inhomogeneities inside the parent material. This was always found to be the case for thin joints tested at temperatures up to 1350C in air. This observation suggests that the strength of Cerastar RB-SIC material containing a thin joint is not limited by the joint strength but by the strength of the bulk (parent) materials.

  19. Practice of Sealants and Preventive Resin Restorations Among Malaysian Dentists.

    PubMed

    Chin, Zhe W; Chong, Wai S; Mani, Shani A

    2016-01-01

    To assess the knowledge, attitude and utilisation regarding fissure sealants (FS) and preventive resin restorations (PRR) among Malaysian dentists. A questionnaire consisting of 35 questions was distributed by mail or an online survey to 425 registered dentists selected according to place of work by stratified random sampling. One hundred fifty-three dentists responded to the survey. A positive attitude towards FS and PRR was noted among most Malaysian dentists. About half of the respondents used FS/PRR occasionally (48.4%), while few (13.7%) applied them routinely. The majority of the dentists agreed that minimally invasive dentistry is important and FS are effective in caries prevention, using them on high caries-risk individuals. Most of the dentists used pumice or paste to clean teeth before placing FS/PRR. A significant number of dentists used a bonding agent prior to placing FS. Although only 57.5% dentists were aware of guidelines for FS use, most dentists agreed that guidelines are important. Although there was a positive attitude towards FS/PRR, few dentists applied them routinely. Some of the steps undertaken for placement of FS and PRR were outdated. Updating local guidelines for dentists to ensure uniform practice of FS and PRR is justified.

  20. Strength of laser welded joints of polypropylene composites

    NASA Astrophysics Data System (ADS)

    Votrubec, V.; Hisem, P.; Vinšová, L.; Lukášová, V.

    2017-11-01

    This paper deals with experimental tests of laser welded polypropylene composites. Polymers, such as polypropylene, are often filled with fibres in order to increase their mechanical properties. The welding procedure can also influence material properties nearby weld joints. Therefore the strength of weld joints is lower than strength of primary materials. This effect is proved by realized shear tests. Polymer specimens were filled with 20 % and 40 % of glass fibres and all possible combinations of specimens were welded for experiments. There is also discussed influence of volume fraction of glass fibres in polypropylene on the strength of weld joint.

  1. Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study.

    PubMed

    Lee, Cheng-Hung; Shih, Cheng-Min; Huang, Kui-Chou; Chen, Kun-Hui; Hung, Li-Kun; Su, Kuo-Chih

    2016-11-01

    Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18 mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. High pressure ceramic joint

    DOEpatents

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  3. Can extended photoactivation time of resin-based fissure sealer materials improve ultimate tensile strength and decrease water sorption/solubility?

    PubMed

    Borges, Boniek Castillo Dutra; Souza-Júnior, Eduardo José; Catelan, Anderson; Paulillo, Luís Alexandre Maffei Sartini; Aguiar, Flávio Henrique Baggio

    2012-10-01

    This study aimed to evaluate the impact of extended photoactivation time on ultimate tensile strength (UTS), water sorption (WS) and solubility (WSB) of resin-based materials used as fissure-sealants. A fissure-sealant (Fluroshield) and a flowable composite (Permaflo) polymerized for 20 and 60 seconds were tested. For UTS, 20 hourglass shaped samples were prepared representing two materials and two photoactivation time (n=5). After 24-h dry-storage, samples were tested in tension using a universal testing machine at a cross-head speed of 0.5 mm/min (UTS was calculated in MPa). For WS and WSB, 20 disks with 5 mm diameter and 1 mm height (n=5) were prepared and volumes were calculated (mm(3)). They were transferred to desiccators until a constant mass was obtained (m1) and were subsequently immersed in distilled water until no alteration in mass was detected (m2). Samples were reconditioned to constant mass in desiccators (m3). WS and WSB were determined using the equations m2-m3/V and m1-m3/V, respectively. Data were subjected to two-way ANOVA and Tukey's HSD test (P<.05). There was no significant difference between materials or photoactivation times for the UTS and WS. Permaflo presented lower but negative WSB compared to Fluroshield. Extended photoactivation time did not improve the physical properties tested. Fluroshield presented physical properties that were similar to or better than Permaflo.

  4. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay; Ensor, Joe E.

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if themore » absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.« less

  5. Advanced Duct Sealing Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, Max H.; Walker, Iain S.

    Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with naturalmore » rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were

  6. The influence of joint technologies on ELV recyclability.

    PubMed

    Soo, Vi Kie; Compston, Paul; Doolan, Matthew

    2017-10-01

    Stricter vehicle emission legislation has led to the increasing use of lightweight materials and multi-material concepts to reduce the vehicle mass. To account for the complexity of multi-material vehicle designs, the choice of joining techniques used is becoming more diverse. Moreover, the different material combinations, and their respective joining methods play an important role in determining the potential of full material separation in a closed-loop system. This paper evaluates the types of joining technologies used in the automotive industry, and identifies those that hinder the sorting of ELV materials. The study is based on an industrial shredding trial of car doors. Observations from the case study showed that steel screws and bolts are increasingly used to combine different material types and are less likely to be perfectly liberated during the shredding process. The characteristics of joints that lead to impurities and valuable material losses, such as joint strength, material type, size, diameter, location, and protrusion level, can influence the material liberation in the current sorting practices and thus, lead to ELV waste minimisation. Additionally, the liberation of joints is also affected by the density and thickness of materials being joined. Correlation analyses are carried out to further support the influence of mechanical screws and bolts on material separation efficiencies. The observations are representative of the initial phases of current global ELV sorting practices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Global-Local Finite Element Analysis of Bonded Single-Lap Joints

    NASA Technical Reports Server (NTRS)

    Kilic, Bahattin; Madenci, Erdogan; Ambur, Damodar R.

    2004-01-01

    Adhesively bonded lap joints involve dissimilar material junctions and sharp changes in geometry, possibly leading to premature failure. Although the finite element method is well suited to model the bonded lap joints, traditional finite elements are incapable of correctly resolving the stress state at junctions of dissimilar materials because of the unbounded nature of the stresses. In order to facilitate the use of bonded lap joints in future structures, this study presents a finite element technique utilizing a global (special) element coupled with traditional elements. The global element includes the singular behavior at the junction of dissimilar materials with or without traction-free surfaces.

  8. Radiation hydrodynamic effects in two beryllium plates with an idealized aluminum joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belkov, S.A.; Mkhitarian, L.S.; Vinokurov, O.A.

    A beryllium capsule formed from two hemispherical shells with a thin bond is one possible ignition target for the National Ignition Facility [J. A. Paisner {ital et al.}, Laser Focus World {bold 30}, 75 (1994)] Nonuniformities in density, opacity, and interface position at the joint between these hemishells will initiate two-dimensional (2-D) perturbations of the shock wave and material behind the shock as the shock passes through the shell perpendicular to the joint width. Rarefaction of material flow behind the shock front can cause the interface between the shell and joint material to oscillate in position. The amplitude of thesemore » oscillations may be comparable to the joint width. The evolution of these perturbations is studied by numerically simulating shock passage through flat beryllium plates containing aluminum joints. Using the MIMOSA-ND code [D. Sofronov {ital et al.}, Vopr. At. Nauki Tekh., Ser: Mat. modelirovanie fizicheskih processov {bold 2}, 3 (1990)] two different cases are calculated{emdash}a wide (10 {mu}m) and a narrow (1 {mu}m) joint of aluminum between two 150 {mu}m long semiinfinite beryllium plates. Both cases showed good agreement with an analytic representation of the oscillation behavior. For the narrow joint, a special technique allows the calculation of mixing between the joint and surrounding material caused by the Kelvin{endash}Helmholtz instability. {copyright} {ital 1999 American Institute of Physics.}« less

  9. Materials based on cellulose fabric and PVC with porous structures formed by jointed aza- and oxa-aza-crown macromolecules

    NASA Astrophysics Data System (ADS)

    Fridman, A. Ya.; Tsivadze, A. Yu.; Morozova, E. M.; Sokolova, N. P.; Shiryaev, A. A.; Petukhova, G. A.; Voloshchuk, A. M.; Bardyshev, I. I.; Gorbunov, A. M.; Polyakova, I. Ya.; Novikov, A. K.; Titova, V. N.; Yavich, A. A.; Petrova, N. V.

    2016-12-01

    A material with porous structures formed by jointed aza- and oxa-aza-crowns with peripheral OHgroups is synthesized on the basis of cellulose fabric and PVC transformed into hydroxyethylcyclam. Mesopores are mainly observed on the fiber surface. The specific surface of the material is 6 m2/g; the volume of free space is 0.112 cm3/g. Assuming the internal pores have a disk-like shape, their width is estimated at 2 nm. The material sorbs vapors of aliphatic and aromatic hydrocarbons, alcohols, aldehydes, ketones, amines, amides, nitriles, and sulfoxides. It also swells to a limited degree in organic solvents. When sulfuric acid or sodium hydroxide is sorbed in the pores, compounds of them with H+- and OH--conducting systems of hydrogen bonds are formed.

  10. The Influence of PV Module Materials and Design on Solder Joint Thermal Fatigue Durability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosco, Nick; Silverman, Timothy J.; Kurtz, Sarah

    Finite element model (FEM) simulations have been performed to elucidate the effect of flat plate photovoltaic (PV) module materials and design on PbSn eutectic solder joint thermal fatigue durability. The statistical method of Latin Hypercube sampling was employed to investigate the sensitivity of simulated damage to each input variable. Variables of laminate material properties and their thicknesses were investigated. Using analysis of variance, we determined that the rate of solder fatigue was most sensitive to solder layer thickness, with copper ribbon and silicon thickness being the next two most sensitive variables. By simulating both accelerated thermal cycles (ATCs) and PVmore » cell temperature histories through two characteristic days of service, we determined that the acceleration factor between the ATC and outdoor service was independent of the variables sampled in this study. This result implies that an ATC test will represent a similar time of outdoor exposure for a wide range of module designs. This is an encouraging result for the standard ATC that must be universally applied across all modules.« less

  11. Fibrin Sealant Improves Hemostasis in Peripheral Vascular Surgery: A Randomized Prospective Trial

    PubMed Central

    Schenk, Worthington G.; Burks, Sandra G.; Gagne, Paul J.; Kagan, Steven A.; Lawson, Jeffrey H.; Spotnitz, William D.

    2003-01-01

    Objective To evaluate the efficacy and safety of an investigational fibrin sealant (FS) in a randomized prospective, partially blinded, controlled, multicenter trial. Summary Background Data Upper extremity vascular access surgery using polytetrafluorethylene (PTFE) graft placement for dialysis was chosen as a reproducible, clinically relevant model for evaluating the usefulness of FS. The FS consisted of pooled human fibrinogen (60 mg/mL) and thrombin (500 NIH U/mL). Time to hemostasis was measured, and adverse events were monitored. Methods Consenting adult patients (n = 48) undergoing placement of a standard PTFE graft were randomized in a 2:1:1 ratio to the treatment group using FS (ZLB Bioplasma AG, Bern, Switzerland), oxidized regenerated cellulose (Surgicel, Johnson & Johnson, New Brunswick, NJ), or pressure. Patients received heparin (3,000 IU IVP) before placement of vascular clamps. If the treatment was FS, clamps were left in place for 120 seconds after the application of study material to permit polymerization. If treatment was Surgicel, clamps were left in place until the agent had been applied according to manufacturer’s instructions. If the treatment was pressure, clamps were released as soon as the investigator was ready to apply compression. Immediately after release of the last clamp, the arterial and venous suture lines were evaluated for bleeding. The time to hemostasis at both the venous and arterial sites was recorded. Results Significant (P ≤ .005) reduction in time to hemostasis was achieved in the FS group. Thirteen (54.2%) patients randomized to FS experienced immediate hemostasis at both suture lines following clamp removal compared to no patients using Surgicel or pressure. Only one patient (7.1%) in the Surgicel group and no patients in the pressure group experienced hemostasis at 120 seconds from clamp removal, compared to 13 (54.2%) patients for FS. Adverse events were comparable in all groups. There were no seroconversions

  12. Gaskets for low-energy houses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harr, D.

    1986-05-01

    New materials and techniques make it easier to build today's tight, energy-efficient homes. One system that has won many converts recently is the airtight drywall approach (ADA). ADA relies heavily on the use of foam gasketing. In the ADA building system, nearly all joints--sill to foundation, band joist, wall plate to subfloor, and drywall to frame-are gasketed with foam tapes. The combination of gaskets, drywall, and caulk creates an airtight envelope. Foam gasketing tape is well suited from many of these joints because it is clean, economical, and easy to apply. The right gasket will maintain the seal even ifmore » the joint moves, and won't squeeze out of the joint under compression. Caulk, on the other hand, is messy, hard to apply, and squeezes out of the joint under compression. Saturated urethanes are elastic sealants that always recover, even after being completely compressed. Some saturated urethanes recover faster than others, depending on what saturant is used, but all exert a force to recover because they are urethanes. In the construction industry, where gaskets are likely to be buried permanently within the framework, saturated urethane foam gaskets really make sense.« less

  13. Disassembly Properties of Cementitious Finish Joints Using an Induction Heating Method

    PubMed Central

    Ahn, Jaecheol; Noguchi, Takafumi; Kitagaki, Ryoma

    2015-01-01

    Efficient maintenance and upgrading of a building during its lifecycle are difficult because a cementitious finish uses materials and parts with low disassembly properties. Additionally, the reuse and recycling processes during building demolition also present numerous problems from the perspective of environmental technology. In this study, an induction heating (IH) method was used to disassemble cementitious finish joints, which are widely used to join building members and materials. The IH rapidly and selectively heated and weakened these joints. The temperature elevation characteristics of the cementitious joint materials were measured as a function of several resistor types, including wire meshes and punching metals, which are usually used for cementitious finishing. The disassembly properties were evaluated through various tests using conductive resistors in cementitious joints such as mortar. When steel fiber, punching metal, and wire mesh were used as conductive resistors, the cementitious modifiers could be weakened within 30 s. Cementitious joints with conductive resistors also showed complete disassembly with little residual bond strength.

  14. Fabrication of gas impervious edge seal for a bipolar gas distribution assembly for use in a fuel cell

    DOEpatents

    Kaufman, Arthur; Werth, John

    1986-01-01

    A bipolar gas reactant distribution assembly for use in a fuel cell is disclosed, the assembly having a solid edge seal to prevent leakage of gaseous reactants wherein a pair of porous plates are provided with peripheral slits generally parallel to, and spaced apart from two edges of the plate, the slit being filled with a solid, fusible, gas impervious edge sealing compound. The plates are assembled with opposite faces adjacent one another with a layer of a fusible sealant material therebetween the slits in the individual plates being approximately perpendicular to one another. The plates are bonded to each other by the simultaneous application of heat and pressure to cause a redistribution of the sealant into the pores of the adjacent plate surfaces and to cause the edge sealing compound to flow and impregnate the region of the plates adjacent the slits and comingle with the sealant layer material to form a continuous layer of sealant along the edges of the assembled plates.

  15. Effect of resealing on microleakage of resin composite restorations in relationship to margin design and composite type

    PubMed Central

    Antonson, Sibel A.; Yazici, A. Ruya; Okte, Zeynep; Villalta, Patricia; Antonson, Donald E.; Hardigan, Patrick C.

    2012-01-01

    Objective: To determine the relationship between margin preparation design and resin-composite type on microleakage with or without re-application of surface-penetrating sealant. Methods: Class-I resin-composite restorations were completed for 128 extracted human molars. Half of the margins were beveled, the other half, butt-joint. Half of each group was restored with Filtek-Supreme (FS), the other half with Esthet-X (EX) using their respective adhesive systems. Margins were etched and sealed with a surface-penetrating sealant, Fortify. The samples were stored in water 24h, and thermocycled (5,000 cycles, 5°C–55°C). Then, samples were abraded using a toothbrush machine (6,000 strokes). Half of the restorations from each sealant group (n=16) were resealed, and the other half had no further treatment. Thermocycling and tooth brushing were repeated. The samples were sealed with nail polish, immersed in methylene-blue for 8h, sectioned, and magnified digital photographs were taken. Three examiners assessed dye penetration. A 2×2×2 multi-layered Chi-Square analysis, using Cochran-Mantel-Haenszel test was conducted for statistical analysis. Results: No difference was observed between sealed and resealed FS and EX restorations with butt-joint margins. In beveled margins, resealing caused significantly less microleakage (P<.01). No differences were found between restorations either sealed or resealed with bevel margins. In butt-joint margins, at the leakage level deeper than 2/3 of the preparation depth, resealed FS showed less microleakage than EX resealed restorations (P<.01). Conclusion: Resealing reduced microleakage in bevel margins, however, in butt-joint margins resealing did not affect the leakage. A significant statistical relationship exists between and within resealing, margin preparation design, type of composite, and microleakage. PMID:23077418

  16. Adhesive-bonded scarf and stepped-lap joints

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1973-01-01

    Continuum mechanics solutions are derived for the static load-carrying capacity of scarf and stepped-lap adhesive-bonded joints. The analyses account for adhesive plasticity and adherend stiffness imbalance and thermal mismatch. The scarf joint solutions include a simple algebraic formula which serves as a close lower bound, within a small fraction of a per cent of the true answer for most practical geometries and materials. Digital computer programs were developed and, for the stepped-lap joints, the critical adherend and adhesive stresses are computed for each step. The scarf joint solutions exhibit grossly different behavior from that for double-lap joints for long overlaps inasmuch as that the potential bond shear strength continues to increase with indefinitely long overlaps on the scarf joints. The stepped-lap joint solutions exhibit some characteristics of both the scarf and double-lap joints. The stepped-lap computer program handles arbitrary (different) step lengths and thickness and the solutions obtained have clarified potentially weak design details and the remedies. The program has been used effectively to optimize the joint proportions.

  17. The fatigue strength of riveted joints and lugs

    NASA Technical Reports Server (NTRS)

    Schijve, J

    1956-01-01

    This report deals with a number of tests on riveted joints and lugs for the primary purpose of comparing the several types of riveted joints and to study the effect of various factors on the fatigue strength of lugs. A check was made to ascertain whether or not an estimate of the fatigue life at a certain loading could be made from the dimensions of the joint and the fatigue data of the unnotched materials. Recommendations are made on the proportioning of joints to obtain better fatigue behavior.

  18. [The development of research in tribology of artificial joints].

    PubMed

    Dai, Zhendong; Gong, Juanqing

    2006-06-01

    Aseptic loosening of the prosthesis is a major form for the failure of artificial joints, which results in the conglomeration of wear particles at the bone-implant interface. This paper briefly reviews the recent development of tribology of artificial joints preserving good lubrication, enhancing the wear resistance of materials for the joints, reducing the generation of sensitive-size particles and depressing the debris-tissue reactions. Suggestion for improvement in the design of artificial joints is presented.

  19. A comparative evaluation of the tensile strength of silver soldered joints of stainless steel and cobalt chromium orthodontic wires with band material--an in vitro study.

    PubMed

    Dua, R; Nandlal, B

    2004-03-01

    The present study was conducted to compare and evaluate the tensile strength of silver soldered joints of stainless steel and cobalt-chromium orthodontic wires with band material. An attempt was made to observe the effect of joint site preparation by incorporation of tack welding and increasing metal to metal surface contact area by flattening an end of the wire prior to soldering along with the regularly used round wires without tack welding. A total of 180 wire specimens were soldered to 180 band specimens. Fifteen samples according to joint site preparation were included for each of the wire groups i.e. Gloria (S.S.), Remanium (S.S.) and Remaloy (Co-Cr) wires of 0.036" in diameter. The findings of the study were suggestive that all three wires may be used for preparing silver soldered joints irrespective of the quality of the wire. However, when subjecting the wire to joint site preparation, Gloria (S.S.) wire showed less tensile strength as compared to Remanium and Remaloy.

  20. The Stromal Vascular Fraction From Fat Tissue in the Treatment of Osteochondral Knee Defect: Case Report

    PubMed Central

    Salikhov, Ramil Z.; Masgutov, Ruslan F.; Chekunov, Mikhail A.; Tazetdinova, Leysan G.; Masgutova, Galina; Teplov, Oleg V.; Galimov, Damir; Plakseichuk, Yuri; Yagudin, Ramil; Pankov, Igor O.; Rizvanov, Albert

    2018-01-01

    In this study we applied autologous fat tissue stromal vascular fraction (SVF) cells in combination with microfracturing technique in a 36-year-old man with an osteochondral lesion of the medial femoral condyle 8 months after the injury. Cell material was generated by fat tissue liposuction from the anterior abdominal wall with subsequent extraction of the SVF and injected through a mini-arthrotomy portal with subsequent fibrin sealant fixation. The follow-up period was 2 years. Clinical score improved from 23 to 96 according to IKDC and from 10 to 90 according to EQ-VAS at 24 months follow-up. Magnetic resonance imaging (MRI) before the surgery revealed an osteochondral lesion with development of significant trabecular edema that remained unchanged for 6 months despite conservative treatment. MRI 1 and 2 years after the surgery showed the recovery of the damaged cartilage thickness with somewhat uneven structure and a decrease in the trabecular edema of the femoral condyle. The use of SVF cells with fibrin sealant fixation might be a promising approach in the treatment of osteochondral joint lesions. Further studies are required. PMID:29900170

  1. Ultrasonic Welding of Hybrid Joints

    NASA Astrophysics Data System (ADS)

    Wagner, Guntram; Balle, Frank; Eifler, Dietmar

    2012-03-01

    A central research field of the Institute of Materials Science and Engineering at the University of Kaiserslautern (WKK), Germany, is the realization of innovative hybrid joints by ultrasonic metal welding. This article gives an overview of suitable ultrasonic welding systems as well as of essential machine and material parameters, which influence the quality of the welds. Besides the ultrasonic welding of dissimilar metals such as Al to Cu or Al to steels, the welds between newly developed materials like aluminum foam sandwiches or flat flexible cables also can be realized. Moreover, the joining of glass and ceramic to sheet metals is a point of interest at the WKK. By using the ultrasonic metal welding process, it is possible to realize metal/glass welds with tensile shear strengths of 50 MPa. For metal/ceramic joints, the shear strengths values up to 150 MPa were measured. Finally, selected results about the occurring bonding mechanisms will be discussed.

  2. Thermally Conductive Metal-Tube/Carbon-Composite Joints

    NASA Technical Reports Server (NTRS)

    Copeland, Robert J.

    2004-01-01

    An improved method of fabricating joints between metal and carbon-fiber-based composite materials in lightweight radiators and heat sinks has been devised. Carbon-fiber-based composite materials have been used in such heat-transfer devices because they offer a combination of high thermal conductivity and low mass density. Metal tubes are typically used to carry heat-transfer fluids to and from such heat-transfer devices. The present fabrication method helps to ensure that the joints between the metal tubes and the composite-material parts in such heat-transfer devices have both (1) the relatively high thermal conductances needed for efficient transfer of heat and (2) the flexibility needed to accommodate differences among thermal expansions of dissimilar materials in operation over wide temperature ranges. Techniques used previously to join metal tubes with carbon-fiber-based composite parts have included press fitting and bonding with epoxy. Both of these prior techniques have been found to yield joints characterized by relatively high thermal resistances. The present method involves the use of a solder (63 percent Sn, 37 percent Pb) to form a highly thermally conductive joint between a metal tube and a carbon-fiber-based composite structure. Ordinarily, the large differences among the coefficients of thermal expansion of the metal tube, solder, and carbon-fiber-based composite would cause the solder to pull away from the composite upon post-fabrication cooldown from the molten state. In the present method, the structure of the solder is modified (see figure) to enable it to deform readily to accommodate the differential thermal expansion.

  3. Reusable Solid Rocket Motor Nozzle Joint-4 Thermal Analysis

    NASA Technical Reports Server (NTRS)

    Clayton, J. Louie

    2001-01-01

    This study provides for development and test verification of a thermal model used for prediction of joint heating environments, structural temperatures and seal erosions in the Space Shuttle Reusable Solid Rocket Motor (RSRM) Nozzle Joint-4. The heating environments are a result of rapid pressurization of the joint free volume assuming a leak path has occurred in the filler material used for assembly gap close out. Combustion gases flow along the leak path from nozzle environment to joint O-ring gland resulting in local heating to the metal housing and erosion of seal materials. Analysis of this condition was based on usage of the NASA Joint Pressurization Routine (JPR) for environment determination and the Systems Improved Numerical Differencing Analyzer (SINDA) for structural temperature prediction. Model generated temperatures, pressures and seal erosions are compared to hot fire test data for several different leak path situations. Investigated in the hot fire test program were nozzle joint-4 O-ring erosion sensitivities to leak path width in both open and confined joint geometries. Model predictions were in generally good agreement with the test data for the confined leak path cases. Worst case flight predictions are provided using the test-calibrated model. Analysis issues are discussed based on model calibration procedures.

  4. Strength evaluation of socket joints

    NASA Technical Reports Server (NTRS)

    Rash, Larry C.

    1994-01-01

    This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.

  5. Comparison of cephalonium alone and in combination with an internal teat sealant for dry cow therapy in seasonally calving dairy cows.

    PubMed

    Bates, A J; Chambers, G; Laven, R A

    2016-03-01

    To assess the effect of combining an internal teat sealant (ITS) and a long-acting cephalonium-based dry cow therapy (DCT) on the prevalence of cows with a somatic cell count (SCC) >150,000 cells/mL 60-80 days after calving, and the incidence of clinical mastitis diagnosed by farm staff in the first 100 days after calving. Cows from a spring-calving, pasture-based, dairy farm in the South Canterbury region of New Zealand were randomly allocated to receive cephalonium DCT (n=289) or cephalonium and internal teat sealant (n=304) at the end of lactation. Cows were inspected twice daily by farm staff during the dry period and following calving for signs of mastitis. Individual SCC were determined from herd tests conducted in the previous lactation and following calving. Logistic regression models were used to determine relationships with the prevalence of cows with a SCC >150,000 cells/mL after calving, and survival analysis was used to model time to the first case of clinical mastitis following calving at the cow and quarter level. The OR for a cow with a SCC >150,000 cells/mL after calving, including age and individual SCC in the preceding lactation in the model, was 0.53 (95% CI=0.32-0.89) for cows treated with combination therapy compared to cows receiving cephalonium (p=0.017). At the cow level, including age and preceding SCC in the model, the hazard ratio for diagnosis of clinical mastitis by farm staff in the first 100 days of lactation was 0.60 (95% CI=0.39-0.98) for cows treated with combination therapy compared to cows receiving cephalonium (p=0.04). At the quarter level, the hazard ratio for diagnosis of clinical mastitis, with age included in the model, was 0.41 (95% CI=0.23-0.74) for the combination therapy compared to cephalonium alone (p<0.001). The combination of internal teat sealant and cephalonium DCT was more effective than cephalonium alone at reducing clinical mastitis diagnosed by farm staff in the 100 days after calving, and the prevalence of

  6. Functionally Graded Adhesives for Composite Joints

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    Adhesives with functionally graded material properties are being considered for use in adhesively bonded joints to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. An enhanced joint finite element, which uses an analytical formulation to obtain exact shape functions, is used to model the joint. Furthermore, proof of concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint.

  7. Computed tomographic anatomy of the equine stifle joint.

    PubMed

    Vekens, Elke Van der; Bergman, Erik H J; Vanderperren, Katrien; Raes, Els V; Puchalski, Sarah M; Bree, Henri J J van; Saunders, Jimmy H

    2011-04-01

    To provide a detailed computed tomography (CT) reference of the anatomically normal equine stifle joint. Sample-16 hind limbs from 8 equine cadavers; no horses had evidence of orthopedic disease of the stifle joints. CT of the stifle joint was performed on 8 hind limbs. In all limbs, CT was also performed after intra-articular injection of 60 mL of contrast material (150 mg of iodine/mL) in the lateral and medial compartments of the femorotibial joint and 80 mL of contrast material in the femoropatellar joint (CT arthrography). Reformatted CT images in the transverse, parasagittal, and dorsal plane were matched with corresponding anatomic slices of the 8 remaining limbs. The femur, tibia, and patella were clearly visible. The patellar ligaments, common origin of the tendinous portions of the long digital extensor muscle and peroneus tertius muscle, collateral ligaments, tendinous portion of the popliteus muscle, and cranial and caudal cruciate ligaments could also be consistently evaluated. The cruciate ligaments and the meniscotibial ligaments could be completely assessed in the arthrogram sequences. Margins of the meniscofemoral ligament and the lateral and medial femoropatellar ligaments were difficult to visualize on the precontrast and postcontrast images. CT and CT arthrography were used to accurately identify and characterize osseous and soft tissue structures of the equine stifle joint. This technique may be of value when results from other diagnostic imaging techniques are inconclusive. The images provided will serve as a CT reference for the equine stifle joint.

  8. Time- and temperature-dependent failures of a bonded joint

    NASA Astrophysics Data System (ADS)

    Sihn, Sangwook

    This dissertation summarizes my study of time- and temperature-dependent behavior of a tubular lap bonded joint to provide a design methodology for windmill blade structures. The bonded joint is between a cast-iron rod and a GFRP composite pipe. The adhesive material is an epoxy containing chopped glass fibers. We proposed a new fabrication method to make concentric and void-less specimens of the tubular joint with a thick adhesive bondline to stimulate the root bond of a blade. The thick bondline facilitates the joint assembly of actual blades. For a better understanding of the behavior of the bonded joint, we studied viscoelastic behavior of the adhesive materials by measuring creep compliance at several temperatures during loading period. We observed that the creep compliance depends highly on the period of loading and the temperature. We applied time-temperature equivalence to the creep compliance of the adhesive material to obtain time-temperature shift factors. We also performed constant-rate of monotonically increased uniaxial tensile tests to measure static strength of the tubular lap joint at several temperatures and different strain-rates. We observed two failure modes from load-deflection curves and failed specimens. One is the brittle mode, which was caused by weakness of the interfacial strength occurring at low temperature and short period of loading. The other is the ductile mode, which was caused by weakness of the adhesive material at high temperature and long period of loading. Transition from the brittle to the ductile mode appeared as the temperature or the loading period increased. We also performed tests under uniaxial tensile-tensile cyclic loadings to measure fatigue strength of the bonded joint at several temperatures, frequencies and stress ratios. The fatigue data are analyzed statistically by applying the residual strength degradation model to calculate statistical distribution of the fatigue life. Combining the time

  9. Asian/Pacific Joint Production Programme of Materials for Neo-Literates in Rural Areas Planning Meeting (Tokyo, Japan, March 4-5, 1991). Report.

    ERIC Educational Resources Information Center

    Asian Cultural Centre for UNESCO, Tokyo (Japan).

    This document reports on the 1991 Planning Meeting on Asian/Pacific Joint Production (AJP) Program of Materials for Neo-Literates in Rural Areas, the purpose of which was to discuss Asian Cultural Center for Unesco (ACCU) literacy programs to be carried out under regional cooperation. Opening addresses focused on the success of the cooperative…

  10. Selenide isotope generators for the Galileo Mission: SIG hermetic bimetal weld transition joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnett, W.J.

    1979-08-01

    The successful development of the commercial 6061-T651/Silver/304L explosive clad plate material as a bimetal weld transition joint material, as described herein, satisfies all SIG Galileo design requirements for hermetic weld attachment of stainless steel subassemblies to aluminum alloy generator housing or end cover structures. The application of this type weld transition joint to the hermetic attachment of stainless steel shell connectors is well-developed and tested. Based on on-going life tests of stainless steel receptacle/bimetal ring attachment assemblies and metallurgical characterization studies of this transition joint material, it appears evident that this transition joint material has more than adequate capability tomore » meet the 250 to 300/sup 0/F and 50,000 hr. design life of the SIG/Galileo mission. Its extended life temperture capability may well approach 350 to 400/sup 0/F.« less

  11. Basic in vitro experiment on the adhesive effects of sheet-type hemostatic agents used in combination with a liquid fibrin sealant.

    PubMed

    Ishii, Keiichi; Kawashima, Hideki; Hayama, Takuma; Mayabashira, Sumika; Oka, Shiro; Sugimoto, Toshikado

    2011-11-01

    Various hemostatic agents have been used quite effectively for hemostasis, as well as for providing effective adhesion during laparoscopic partial nephrectomies. In this study, we investigated the adhesiveness to the renal tissue of some sheet-type hemostatic agents used in combination with a liquid fibrin sealant. In Experiment A, component solutions of the fibrin glue (liquid fibrin sealant) were dripped onto a kite string placed annularly on a porcine kidney slice. Then, one of the sheet-type hemostats--namely, the collagen, gelatin, or cellulose hemostat--was placed on the slices, and a string scale was used to measure the force needed to pull the string apart vertically from the kidney slice. Twelve slices were used for each group, and the weight data were analyzed statistically. The tissue adhering to each sheet-type hemostatic agent was fixed in formalin and sliced and then examined by light microscopy after hematoxylin and eosin staining. In Experiment B, the solutions were dripped onto the sheet-type hemostatic agent placed first on the slice, and the force needed for pulling apart the hemostat sheet from the slice was similarly examined. The combination of fibrin glue plus a collagen hemostat was clearly superior in Experiment A, but the hemostat and renal tissue could be pulled apart more easily in Experiment B. These results showed that fibrin glue could not exert its expected adhesive effect unless it is used in combination with another hemostatic agent or is directly applied to renal tissue. It is important to obtain further comparative data among agents and select the appropriate agents, taking into consideration the type of surgery.

  12. Tensile strength of simulated and welded butt joints in W-Cu composite sheet

    NASA Technical Reports Server (NTRS)

    Moore, Thomas J.; Watson, Gordon K.

    1994-01-01

    The weldability of W-Cu composite sheet was investigated using simulated and welded joints. The welded joints were produced in a vacuum hot press. Tensile test results showed that simulated joints can provide strength and failure mode data which can be used in joint design for actual weldments. Although all of the welded joints had flaws, a number of these joints were as strong as the W-Cu composite base material.

  13. Effectiveness of audiovisual distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder.

    PubMed

    Fakhruddin, Kausar Sadia; El Batawi, Hisham Yehia

    2017-01-01

    The aim of this study was to evaluate the effectiveness of audiovisual (AV) distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder. This study was conducted on 28 children diagnosed with autism spectrum disorder, aged 6.5-9.8 years. Children underwent one introductory (desensitization) appointment and three treatment sessions. During the introductory session, children had the procedures explained to them, they watched a movie projected on a screen while oral screening and assessment of cooperation level were carried out. In treatment session I, oral examination, charting, and dental x-rays were undertaken, whereas the children watched movies with or without video eyewear. During treatment sessions II/III, dental prophylaxis was carried out on upper and lower jaws in addition to the application of dental sealants on the right upper and lower and the left upper and lower permanent molars, respectively, while the children were distracted by cartoon movies using video eyewear. Changes in pulse oximeter and heart rate were recorded every 5 min. Independent samples t -test was used to assess the significance of changes in pulse and O 2 saturation levels during each visit. International Caries Detection and Assessment System-code 2 was found to be the most prevalent ( n = 58; 52%). A significant difference ( P < 0.02) was observed in mean heart rate during dental screening of the upper and lower jaws with and without video eyewear. A decrease was observed in the mean heart rate during subsequent treatment sessions. Initial desensitization appointment and "tell-show-do" approach, followed by short and positive treatment sessions, assisted in gaining cooperation and improving behavior in the subjects. Video eyewear distraction proved an effective tool in managing children with autism spectrum disorder during noninvasive preventive dental procedures.

  14. 49 CFR 192.285 - Plastic pipe: Qualifying persons to make joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Plastic pipe: Qualifying persons to make joints... Materials Other Than by Welding § 192.285 Plastic pipe: Qualifying persons to make joints. (a) No person may make a plastic pipe joint unless that person has been qualified under the applicable joining procedure...

  15. 49 CFR 192.285 - Plastic pipe: Qualifying persons to make joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Plastic pipe: Qualifying persons to make joints... Materials Other Than by Welding § 192.285 Plastic pipe: Qualifying persons to make joints. (a) No person may make a plastic pipe joint unless that person has been qualified under the applicable joining procedure...

  16. 49 CFR 192.285 - Plastic pipe: Qualifying persons to make joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Plastic pipe: Qualifying persons to make joints... Materials Other Than by Welding § 192.285 Plastic pipe: Qualifying persons to make joints. (a) No person may make a plastic pipe joint unless that person has been qualified under the applicable joining procedure...

  17. 49 CFR 192.285 - Plastic pipe: Qualifying persons to make joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Plastic pipe: Qualifying persons to make joints... Materials Other Than by Welding § 192.285 Plastic pipe: Qualifying persons to make joints. (a) No person may make a plastic pipe joint unless that person has been qualified under the applicable joining procedure...

  18. Recent advances in computational mechanics of the human knee joint.

    PubMed

    Kazemi, M; Dabiri, Y; Li, L P

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling.

  19. Analysis on the Fracture of Al-Cu Dissimilar Materials Friction Stir Welding Lap Joint

    NASA Astrophysics Data System (ADS)

    Sun, Hongyu; Zhou, Qi; Zhu, Jun; Peng, Yong

    2017-12-01

    Friction stir welding (FWS) is regarded as a more plausible alternative to other welding methods for Al-Cu dissimilar joining. However, the structure of an FSW joint is different from others. In this study, lap joints of 6061 aluminum alloy and commercially pure copper were produced by FSW, and the effects of rotation rate on macromorphology, microstructure and mechanical properties were investigated. In addition, a fracture J integral model was used to analyze the effect of microstructure on the mechanical properties. The results revealed that the macrodefect-free joints were obtained at a feed rate of 150 mm/min and 1100 rpm and that the failure load of the joint reached as high as 4.57 kN and only reached 2.91 kN for the 900 rpm, where tunnel defects were identified. Particle-rich zones composed of Cu particles dispersed in an Al matrix, and "Flow tracks" were observed by the EDS. The J integral results showed that the microdefects on the advancing side cause serious stress concentration compared with the microdefects located on the Al-Cu interface, resulting in the fracture of the joints.

  20. Carboxylate and amino group coated silver nanoparticles as joining materials for copper-to-copper silver joints.

    PubMed

    Oestreicher, A; Röhrich, T; Lerch, M

    2012-12-01

    Organic silver complexes are introduced where silver is linked either with a carboxyl group or with an amino group. Upon heating, nanoparticles are generated if the respective ligands are long enough to act as stabilizing agents in the nanoparticulate regime. With decomposition and volatilization of the organic material, the sintering of silver occurs. The thermal characteristics of the carboxylates silver-n-octanoate, silver-n-decanoate, and AgOOC(CH2OCH2)2CH2OCH3 are compared with silver-n-alkylamines (n = 8, 9, and 12), and their thermal behavior is discussed based on thermogravimetry (TG) measurements. The consecutive stages of a metallization process are addressed based on the properties of AgOOC(CH2OCH2)2CH2OCH3, and the usable effects of the individual phases of this metal organic compound are analyzed by cross-sectional scanning electron microscope (SEM) images of silver joints. Selection criteria are addressed based on the thermal behavior. A mechanism for the joining process is proposed, considering formation and sintering of the nanoparticles. It was found that the bulk material can be used for low-temperature joining processes. Strong adherence to copper as a basic material can be achieved.

  1. Investigation of displacement, strain and stress in single step transversely isotropic elastic bonded joint

    NASA Astrophysics Data System (ADS)

    Apu, Md. Jakaria; Islam, Md. Shahidul

    2016-07-01

    Bi-material joint is often used in many advanced materials and structures. Determination of the bonding strength at the interface is very difficult because of the presence of the stress singularity. In this paper, the displacement and stress fields of a transversely isotropic bi-material joint around an interface edge are determined. Autodesk Simulation Mechanical 2015 is used to carry out the numerical computations. Stress and displacement fields demonstrate that the values near the edge of joint where the stress singularity occurs are larger than that at the inner portion. From the numerical results, it is suggested that de-bonding of the interface may occur at the interface edge of the joint due to the higher stress concentration at the free edge.

  2. Tribological characterization of the drill pipe tool joints reconditioned by using welding technologies

    NASA Astrophysics Data System (ADS)

    Caltaru, M.; Badicioiu, M.; Ripeanu, R. G.; Dinita, A.; Minescu, M.; Laudacescu, E.

    2018-01-01

    Drill pipe is a seamless steel pipe with upset ends fitted with special threaded ends that are known as tool joints. During drilling operations, the wall thickness of the drill pipe and the outside diameter of the tool joints will be gradually reduced due to wear. The present research work investigate the possibility of reconditioning the drill pipe tool joints by hardbanding with a new metal-cored coppered flux cored wire, Cr-Mo alloyed, using the gas metal active welding process, taking into considerations two different hardbanding technologies, consisting in: hardbanding drill pipe tool joints after removing the old hardbanding material and surface reconstruction with a compensation material (case A), and hardbanding tool joint drill pipe, without removing the old hardbanding material (case B). The present paper brings forward the experimental researches regarding the tribological characterization of the reconditioned drill pipe tool joint by performing macroscopic analyses, metallographic analyses, Vickers hardness measurement, chemical composition measurement and wear tests conducted on ball on disk friction couples, in order to certify the quality of the hardbanding obtained by different technological approaches, to validate the optimum technology.

  3. Progressive Damage Analysis of Bonded Composite Joints

    NASA Technical Reports Server (NTRS)

    Leone, Frank A., Jr.; Girolamo, Donato; Davila, Carlos G.

    2012-01-01

    The present work is related to the development and application of progressive damage modeling techniques to bonded joint technology. The joint designs studied in this work include a conventional composite splice joint and a NASA-patented durable redundant joint. Both designs involve honeycomb sandwich structures with carbon/epoxy facesheets joined using adhesively bonded doublers.Progressive damage modeling allows for the prediction of the initiation and evolution of damage within a structure. For structures that include multiple material systems, such as the joint designs under consideration, the number of potential failure mechanisms that must be accounted for drastically increases the complexity of the analyses. Potential failure mechanisms include fiber fracture, intraply matrix cracking, delamination, core crushing, adhesive failure, and their interactions. The bonded joints were modeled using highly parametric, explicitly solved finite element models, with damage modeling implemented via custom user-written subroutines. Each ply was discretely meshed using three-dimensional solid elements. Layers of cohesive elements were included between each ply to account for the possibility of delaminations and were used to model the adhesive layers forming the joint. Good correlation with experimental results was achieved both in terms of load-displacement history and the predicted failure mechanism(s).

  4. Experimental determination of satellite bolted joints thermal resistance

    NASA Technical Reports Server (NTRS)

    Mantelli, Marcia Barbosa Henriques; Basto, Jose Edson

    1990-01-01

    The thermal resistance was experimentally determined of the bolted joints of the first Brazilian satellite (SCD 01). These joints, used to connect the satellite structural panels, are reproduced in an experimental apparatus, keeping, as much as possible, the actual dimensions and materials. A controlled amount of heat is forced to pass through the joint and the difference of temperature between the panels is measured. The tests are conducted in a vacuum chamber with liquid nitrogen cooled walls, that simulates the space environment. Experimental procedures are used to avoid much heat losses, which are carefully calculated. Important observations about the behavior of the joint thermal resistance with the variation of the mean temperature are made.

  5. Thermal-stress-free fasteners for joining orthotropic materials

    NASA Technical Reports Server (NTRS)

    Blosser, M. L.

    1987-01-01

    Hot structures fabricated from orthotropic materials are an attractive design option for future high speed vehicles. Joining subassemblies of these materials with standard cylindrical fasteners can lead to loose joints or highly stressed joints due to thermal stress. A method has been developed to eliminate thermal stresses and maintain a tight joint by shaping the fastener and mating hole. This method allows both materials (fastener and structure), with different coefficients of thermal expansion (CTEs) in each of the three material directions, to expand freely with temperature yet remain in contact. For the assumptions made in the analysis, the joint will remain snug, yet free of thermal stress at any temperature. Finite element analysis was used to verify several thermal-stress-free fasteners and to show that conical fasteners, which are thermal-stress-free for isotropic materials, can reduce thermal stresses for transversely isotropic materials compared to a cylindrical fastener. Equations for thermal-stress-free shapes are presented and typical fastener shapes are shown.

  6. Recent Advances in Computational Mechanics of the Human Knee Joint

    PubMed Central

    Kazemi, M.; Dabiri, Y.; Li, L. P.

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling. PMID:23509602

  7. Mechanical Behavior of Dowel-Type Joints Made of Wood Scrimber Composite

    PubMed Central

    He, Minjuan; Tao, Duo; Li, Zheng; Li, Maolin

    2016-01-01

    As a renewable building material with low embodied energy characteristics, wood has gained more and more attention in the green and sustainable building industry. In terms of material resource and physical properties, scrimber composite not only makes full use of fast-growing wood species, but also has better mechanical performance and less inherent variability than natural wood material. In this study, the mechanical behavior of bolted beam-to-column joints built with a kind of scrimber composite was investigated both experimentally and numerically. Two groups of specimens were tested under monotonic and low frequency cyclic loading protocols. The experimental results showed that the bolted joints built with scrimber composite performed well in initial stiffness, ductility, and energy dissipation. A three-dimensional (3D) non-linear finite element model (FEM) for the bolted beam-to-column joints was then developed and validated by experimental results. The validated model was further used to investigate the failure mechanism of the bolted joints through stress analysis. This study can contribute to the application of the proposed scrimber composite in structural engineering, and the developed FEM can serve as a useful tool to evaluate the mechanical behavior of such bolted beam-to-column joints with different configurations in future research. PMID:28773703

  8. Mechanical Behavior of Dowel-Type Joints Made of Wood Scrimber Composite.

    PubMed

    He, Minjuan; Tao, Duo; Li, Zheng; Li, Maolin

    2016-07-15

    As a renewable building material with low embodied energy characteristics, wood has gained more and more attention in the green and sustainable building industry. In terms of material resource and physical properties, scrimber composite not only makes full use of fast-growing wood species, but also has better mechanical performance and less inherent variability than natural wood material. In this study, the mechanical behavior of bolted beam-to-column joints built with a kind of scrimber composite was investigated both experimentally and numerically. Two groups of specimens were tested under monotonic and low frequency cyclic loading protocols. The experimental results showed that the bolted joints built with scrimber composite performed well in initial stiffness, ductility, and energy dissipation. A three-dimensional (3D) non-linear finite element model (FEM) for the bolted beam-to-column joints was then developed and validated by experimental results. The validated model was further used to investigate the failure mechanism of the bolted joints through stress analysis. This study can contribute to the application of the proposed scrimber composite in structural engineering, and the developed FEM can serve as a useful tool to evaluate the mechanical behavior of such bolted beam-to-column joints with different configurations in future research.

  9. Dissimilar Brazed Joints Between Steel and Tungsten Carbide

    NASA Astrophysics Data System (ADS)

    Voiculescu, I.; Geanta, V.; Binchiciu, H.; Iovanas, D.; Stefanoiu, R.

    2017-06-01

    Brazing is a joining process used to obtain heterogeneous assemblies between different materials, such as steels, irons, non-ferrous metals, ceramics etc. Some application, like asphalt cutters, require quick solutions to obtain dissimilar joints at acceptable costs, given the very short period of operation of these parts. This paper presents some results obtained during the brazing of dissimilar joints between steel and tungsten carbide by using different types of Ag-Cu system filler materials alloyed with P and Sn. The brazing techniques used were oxygen-gas flame and induction joining. The brazing behaviour was analysed in cross sections by optical and electron microscopy. The metallographic analysis enhanced the adhesion features and the length of penetration in the joining gap. The melting range of the filler materials was measured using thermal analysis.

  10. Wear-screening and joint simulation studies vs. materials selection and prosthesis design.

    PubMed

    Clarke, I C

    1982-01-01

    Satisfactory friction and wear performance of orthomedic biomaterials is an essential criterion for both hemiarthroplasty and total joint replacements. This report will chart the clinical historical experience of candidate biomaterials with their wear resistance and compare/contrast these data to experimental test predictions. The latter review will encompass publications dealing with both joint simulators and the more basic friction and wear screening devices. Special consideration will be given to the adequacy of the test protocol, the design of the experimental machines, and the accuracy of the measurement techniques. The discussion will then center on clinical reality vs. experimental adequacy and summarize current developments.

  11. Solar Alpha Rotary Joint Anomaly: The Materials and Processes Perspective

    NASA Technical Reports Server (NTRS)

    Basta, Erin A.; Dasgupta, Rijib; Figert, John; Jerman, Greg; Wright, Clara; Petrakis, Dennis; Golden, Johnny L.

    2009-01-01

    This slide presentation reviews the anomaly discovered on the Solar Alpha Rotary Joint (SARJ). This anomaly was discovered when the SARJ mechanism produced anomalous telemetry and noticeable vibrations. Metallic debris was discovered throughout the vicinity of the mechanism. Samples were taken from the SARJ, and the findings of the analysis are discussed.

  12. Initial experience with the use of fibrin sealant for the fixation of the prosthetic mesh in laparoscopic transabdominal preperitoneal hernia repair.

    PubMed

    Langrehr, J M; Schmidt, S C; Neuhaus, P

    2005-08-01

    Laparoscopic inguinal hernia repair offers more rapid recovery and less pain than with the traditional open approach. However, injury to the nerves of the lumbar plexus with subsequent chronic pain or neuralgia has a reported incidence of 2% during laparoscopic hernia repair, particularly when the transabdominal preperitoneal technique (TAPP) is used. These complications are inherent to the use of staples for fixation of the mesh. To avoid nerve irritation, we considered the use of fibrin sealant for the fixation of the mesh instead of staples. The aim of this study was to evaluate this technique and to compare the short-term follow-up of these patients with patients who underwent the staple repair technique. This is the first reported use of fibrin sealant in laparoscopic TAPP hernia repair. Between September and November 2004, we performed 17 consecutive laparoscopic hernia repairs (TAPP) in 14 patients (3 bilateral hernias) with primary hernias. The prosthetic mesh was fixed (10 x 15 cm) with 1 ml fibrin. The fibrin was applied using a special laparoscopic applicator. The peritoneum was closed with absorbable sutures. The postoperative course of these patients was compared with a cohort of matched patients who received the traditional staple fixation of the prosthetic mesh. Patients were evaluated at a median follow-up of 10.4 months (3.8-16.0 months). All patients underwent postoperative physical examinations. No recurrent hernia was found. There were 2 seromas and one hematoma in the stapled group. In the stapled group, one patient had pain in the area of the lateral femoral cutaneous nerve. There was no postoperative complication in the non-stapled group. Fibrin fixation of the mesh during laparoscopic transabdominal preperitoneal inguinal hernia repair is feasible without higher risk of recurrences. In addition the fibrin fixation method may decrease postoperative neuralgia and reduce the incidence of postoperative seromas and hematomas.

  13. Coal-tar-based pavement sealants—a potent source of PAHs

    USGS Publications Warehouse

    Mahler, Barbara J.; Van Metre, Peter C.

    2017-01-01

    P avement sealants are applied to the asphalt pavement of many parking lots, driveways, and even playgrounds in North America (Figure 1), where, when first applied, they render the pavement glossy black and looking like new. Sealant products used commercially in the central, eastern, and northern United States typically are coal-tarbased, whereas those used in the western United States typically are asphalt-based. Although the products look similar, they are chemically different. Coal-tarbased pavement sealants typically are 25-35 percent (by weight) coal tar or coal-tar pitch, materials that are known human carcinogens and that contain high concentrations of polycyclic aromatic hydrocarbons (PAHs) and related chemicals (unless otherwise noted, all Figure 1. Pavement sealant is commonly used to seal parking lots, playgrounds, and driveways throughout the United States. Sealants used in the central, northern, eastern, and southern United States typically contain coal tar or coal-tar pitch, both of which are known human carcinogens. Photos by the U.S. Geological Survey. data in this article are from Mahler et al. 2012 and references therein).

  14. Torque Limit for Bolted Joint For Composites. Part B; Experimentation

    NASA Technical Reports Server (NTRS)

    Kostreva, Kristian M.

    2003-01-01

    Today, aerospace quality composite parts are generally made from either a unidirectional tape or a fabric prepreg form depending on the application. The matrix material, typically epoxy because of it dimensional stability, is pre-impregnated onto the fibers to ensure uniform distribution. Both of these composite forms are finding themselves used in applications where a joint is required. Two widely used joint methods are the classic mechanically fastened joint, and the contemporary bonded joint; however, the mechanically fastened joint is most commonly used by design engineers. A major portion of the research up-to-date about bolted composite joints has dealt with the inplane static load capacity. This work has helped to spawn standards dealing with filled-hole static joint strength. Other research has clearly shown that the clamp-up load in the mechanical fastener significantly affects the joint strength in a beneficial manner by reducing the bearing strength dependence of the composite laminate. One author reported a maximum increase in joint strength of 28%. This finding has helped to improve the reliability and efficiency of the joint in a composite structure.

  15. Analysis of a Preloaded Bolted Joint in a Ceramic Composite Combustor

    NASA Technical Reports Server (NTRS)

    Hissam, D. Andy; Bower, Mark V.

    2003-01-01

    This paper presents the detailed analysis of a preloaded bolted joint incorporating ceramic materials. The objective of this analysis is to determine the suitability of a joint design for a ceramic combustor. The analysis addresses critical factors in bolted joint design including preload, preload uncertainty, and load factor. The relationship between key joint variables is also investigated. The analysis is based on four key design criteria, each addressing an anticipated failure mode. The criteria are defined in terms of margin of safety, which must be greater than zero for the design criteria to be satisfied. Since the proposed joint has positive margins of safety, the design criteria are satisfied. Therefore, the joint design is acceptable.

  16. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

    PubMed Central

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung

    2014-01-01

    PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material. PMID:25551010

  17. A Single-Lap Joint Adhesive Bonding Optimization Method Using Gradient and Genetic Algorithms

    NASA Technical Reports Server (NTRS)

    Smeltzer, Stanley S., III; Finckenor, Jeffrey L.

    1999-01-01

    A natural process for any engineer, scientist, educator, etc. is to seek the most efficient method for accomplishing a given task. In the case of structural design, an area that has a significant impact on the structural efficiency is joint design. Unless the structure is machined from a solid block of material, the individual components which compose the overall structure must be joined together. The method for joining a structure varies depending on the applied loads, material, assembly and disassembly requirements, service life, environment, etc. Using both metallic and fiber reinforced plastic materials limits the user to two methods or a combination of these methods for joining the components into one structure. The first is mechanical fastening and the second is adhesive bonding. Mechanical fastening is by far the most popular joining technique; however, in terms of structural efficiency, adhesive bonding provides a superior joint since the load is distributed uniformly across the joint. The purpose of this paper is to develop a method for optimizing single-lap joint adhesive bonded structures using both gradient and genetic algorithms and comparing the solution process for each method. The goal of the single-lap joint optimization is to find the most efficient structure that meets the imposed requirements while still remaining as lightweight, economical, and reliable as possible. For the single-lap joint, an optimum joint is determined by minimizing the weight of the overall joint based on constraints from adhesive strengths as well as empirically derived rules. The analytical solution of the sin-le-lap joint is determined using the classical Goland-Reissner technique for case 2 type adhesive joints. Joint weight minimization is achieved using a commercially available routine, Design Optimization Tool (DOT), for the gradient solution while an author developed method is used for the genetic algorithm solution. Results illustrate the critical design variables

  18. Testing of household products and materials for emission of toluene diisocyanate.

    PubMed

    Kelly, T J; Myers, J D; Holdren, M W

    1999-06-01

    Polyurethane products were subjected to chamber testing to determine their emission rates of 2,4- and 2,6-toluene diisocyanate (TDI). The polyurethane (PU) products included carpet padding, furniture cushions, sheet foam, varnishes, and sealants, as well as a commercially-applied water sealant product for concrete that contained up to 4 percent TDI by weight. The PU products were screened in a 9-L glass chamber, under elevated temperature and chamber loading conditions, using both a time-integrated sampling and analysis method specific for TDI and a continuous but non-specific real-time monitor for isocyanates. None of the products normally found in residences showed a positive response in the screening tests, indicating that TDI emissions and consequently toxic effects from such products are negligible. However, the commercially-applied water sealant gave a positive response in the screening test. Further testing of that product at realistic temperatures showed initial TDI emission rates of about 300,000 micrograms/m2/hr, with emissions lasting only one hour or less. At 21 and 27 degrees C, about 1 percent and 5 percent, respectively, of the TDI content of the product was released to the air. The emitted TDI was predominantly the 2,6-isomer, although the TDI originally present in the product was predominantly the 2,4-isomer.

  19. Developing a Sealing Material: Effect of Epoxy Modification on Specific Physical and Mechanical Properties.

    PubMed

    Schoberleitner, Christoph; Archodoulaki, Vasiliki-Maria; Koch, Thomas; Lüftl, Sigrid; Werderitsch, Markus; Kuschnig, Gerhard

    2013-11-27

    To develop a matched sealing material for socket rehabilitation of grey cast iron pipes, an epoxy resin is modified by the addition of different components to improve the flexibility. Three different modifications are made by adding ethylene-propylene diene monomer (EPDM) rubber powder, reactive liquid polymer (ATBN) and epoxidized modifier. In this paper the effect of the modification method as well as the influence of absorption of water on the mechanical and physical properties are analyzed in terms of: tensile strength, modulus of elasticity, adhesion performance, pressure resistance, glass transition temperature and water content. A comparison with neat epoxy shows for all materials that the modulus of elasticity and strength decrease. Unlike other tested modification methods, the modification with rubber powder did not enhance the flexibility. All materials absorb water and a plasticization effect arises with further changes of mechanical and physical properties. The application of the sealant on the grey cast iron leads to a reduction of the strain at break (in comparison to the common tensile test of the pure materials) and has to be evaluated. The main requirement of pressure resistance up to 1 MPa was tested on two chosen materials. Both materials fulfill this requirement.

  20. The effect of TISSEEL fibrin sealant on seroma formation following complex abdominal wall hernia repair: a single institutional review and derived cost analysis.

    PubMed

    Azoury, S C; Rodriguez-Unda, N; Soares, K C; Hicks, C W; Baltodano, P A; Poruk, K E; Hu, Q L; Cooney, C M; Cornell, P; Burce, K; Eckhauser, F E

    2015-12-01

    The authors evaluated the ability of a fibrin sealant (TISSEEL™: Baxter Healthcare Corp, Deerfield, IL, USA) to reduce the incidence of post-operative seroma following abdominal wall hernia repair. We performed a 4-year retrospective review of patients undergoing abdominal wall hernia repair, with and without TISSEEL, by a single surgeon (FEE) at The Johns Hopkins Hospital. Demographics, surgical risk factors, operative data and 30-day outcomes, including wound complications and related interventions, were compared. The quantity and cost of Tisseel per case was reviewed. A total of 250 patients were evaluated: 127 in the TISSEEL group and 123 in the non-TISSEEL control group. The average age for both groups was 56.6 years (P = 0.97). The majority of patients were female (TISSEEL 52.8%, non-TISSEEL 56.1%, P = 0.59) and ASA Class III (TISSEEL 56.7%, non-TISSEEL 58.5%, P = 0.40). There was no difference in the average defect size for both groups (TISSEEL 217 ± 187.6 cm(2), non-TISSEEL 161.3 ± 141.5 cm(2), P = 0.36). Surgical site occurrences occurred in 18.1% of the TISSEEL and 13% of the non-TISSEEL group (P = 0.27). There was a trend towards an increased incidence of seroma in the TISSEEL group (TISSEEL 11%, non-TISSEEL 4.9%, P = 0.07). A total of $124,472.50 was spent on TISSEEL, at an average cost of $995.78 per case. In the largest study to date, TISSEEL™ application offered no advantage for the reduction of post-operative seroma formation following complex abdominal hernia repair. Moreover, the use of this sealant was associated with significant costs.

  1. Impact of mechanical heterogeneity on joint density in a welded ignimbrite

    NASA Astrophysics Data System (ADS)

    Soden, A. M.; Lunn, R. J.; Shipton, Z. K.

    2016-08-01

    Joints are conduits for groundwater, hydrocarbons and hydrothermal fluids. Robust fluid flow models rely on accurate characterisation of joint networks, in particular joint density. It is generally assumed that the predominant factor controlling joint density in layered stratigraphy is the thickness of the mechanical layer where the joints occur. Mechanical heterogeneity within the layer is considered a lesser influence on joint formation. We analysed the frequency and distribution of joints within a single 12-m thick ignimbrite layer to identify the controls on joint geometry and distribution. The observed joint distribution is not related to the thickness of the ignimbrite layer. Rather, joint initiation, propagation and termination are controlled by the shape, spatial distribution and mechanical properties of fiamme, which are present within the ignimbrite. The observations and analysis presented here demonstrate that models of joint distribution, particularly in thicker layers, that do not fully account for mechanical heterogeneity are likely to underestimate joint density, the spatial variability of joint distribution and the complex joint geometries that result. Consequently, we recommend that characterisation of a layer's compositional and material properties improves predictions of subsurface joint density in rock layers that are mechanically heterogeneous.

  2. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

    PubMed

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-12-01

    This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

  3. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint

    PubMed Central

    Zhang, Xiangming

    2011-01-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint. PMID:21061141

  4. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    PubMed

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

  5. Strength of Welded Joints in Tubular Members for Aircraft

    NASA Technical Reports Server (NTRS)

    Whittemore, H L; Brueggeman, W C

    1931-01-01

    The object of this investigation is to make available to the aircraft industry authoritative information on the strength, weight, and cost of a number of types of welded joints. This information will, also, assist the aeronautics branch in its work of licensing planes by providing data from which the strength of a given joint may be estimated. As very little material on the strength of aircraft welds has been published, it is believed that such tests made by a disinterested governmental laboratory should be of considerable value to the aircraft industry. Forty joints were welded under procedure specifications and tested to determine their strengths. The weight and time required to fabricate were also measured for each joint.

  6. Nano Enabled Thermo-Mechanical Materials in Adhesive Joints: A New Paradigm to Materials Functionality (Preprint)

    DTIC Science & Technology

    2006-12-01

    interface as well as to minimize the interface contact resistance. There is an on- going effort by numerous researchers of dispersing conductive nano...constituents (single wall carbon nanotube (SWCNT), multi wall carbon nano tube ( MWCNT )) in polymers (adhesive) to enhance its thermal conductivity [1...propose to use vertically aligned MWCNT in joints to enhance through-thickness conductivity [10] because of its known high thermal conductivity

  7. Structural behavior of the space shuttle SRM Tang-Clevis joint

    NASA Technical Reports Server (NTRS)

    Greene, W. H.; Knight, N. F., Jr.; Stockwell, A. E.

    1986-01-01

    The space shuttle Challenger accident investigation focused on the failure of a tang-clevis joint on the right solid rocket motor. The existence of relative motion between the inner arm of the clevis and the O-ring sealing surface on the tang has been identified as a potential contributor to this failure. This motion can cause the O-rings to become unseated and therefore lose their sealing capability. Finite element structural analyses have been performed to predict both deflections and stresses in the joint under the primary, pressure loading condition. These analyses have demonstrated the difficulty of accurately predicting the structural behavior of the tang-clevis joint. Stresses in the vicinity of the connecting pins, obtained from elastic analyses, considerably exceed the material yield allowables indicating that inelastic analyses are probably necessary. Two modifications have been proposed to control the relative motion between the inner clevis arm and the tang at the O-ring sealing surface. One modification, referred to as the capture feature, uses additional material on the inside of the tang to restrict motion of the inner clevis arm. The other modification uses external stiffening rings above and below the joint to control the local bending in the shell near the joint. Both of these modifications are shown to be effective in controlling the relative motion in the joint.

  8. Structural behavior of the space shuttle SRM tang-clevis joint

    NASA Technical Reports Server (NTRS)

    Greene, William H.; Knight, Norman F., Jr.; Stockwell, Alan E.

    1988-01-01

    The space shuttle Challenger accident investigation focused on the failure of a tang-clevis joint on the right solid rocket motor. The existence of relative motion between the inner arm of the clevis and the O-ring sealing surface on the tang has been identified as a potential contributor to this failure. This motion can cause the O-rings to become unseated and therefore lose their sealing capability. Finite element structural analyses have been performed to predict both deflections and stresses in the joint under the primary, pressure loading condition. These analyses have demonstrated the difficulty of accurately predicting the structural behavior of the tang-clevis joint. Stresses in the vicinity of the connecting pins, obtained from elastic analyses, considerably exceed the material yield allowables indicating that inelastic analyses are probably necessary. Two modifications have been proposed to control the relative motion between the inner clevis arm and the tang at the O-ring sealing surface. One modification, referred to as the capture feature, uses additional material on the inside of the tang to restrict motion of the inner clevis arm. The other modification uses external stiffening rings above and below the joint to control the local bending in the shell near the joint. Both of these modifications are shown to be effective in controlling the relative motion in the joint.

  9. Challenges and Opportunities in Design, Fabrication, and Testing of High Temperature Joints in Ceramics and Ceramic Composites

    NASA Technical Reports Server (NTRS)

    Singh, M.; Levine, S. R. (Technical Monitor)

    2001-01-01

    Ceramic joining has been recognized as an enabling technology for successful utilization of advanced ceramics and composite materials. A number of joint design and testing issues have been discussed for ceramic joints in silicon carbide-based ceramics and fiber-reinforced composites. These joints have been fabricated using an affordable, robust ceramic joining technology (ARCJoinT). The microstructure and good high temperature mechanical capability (compressive and flexural strengths) of ceramic joints in silicon carbide-based ceramics and composite materials are reported.

  10. Stimulation of morphofunctional repair of the facial nerve with photobiomodulation, using the end-to-side technique or a new heterologous fibrin sealant.

    PubMed

    Rosso, Marcelie Priscila de Oliveira; Rosa Júnior, Geraldo Marco; Buchaim, Daniela Vieira; German, Iris Jasmin Santos; Pomini, Karina Torres; de Souza, Rafael Gomes; Pereira, Mizael; Favaretto Júnior, Idvaldo Aparecido; Bueno, Cleuber Rodrigo de Souza; Gonçalves, Jéssica Barbosa de Oliveira; Ferreira Júnior, Rui Seabra; Barraviera, Benedito; Andreo, Jesus Carlos; Buchaim, Rogério Leone

    2017-10-01

    This research evaluated the influence of Photobiomodulation Therapy (PBMT) on lesions of the facial nerve repaired with the end-to-side technique or coaptation with a new heterologous fibrin sealant. Thirty-two Wistar rats were separated into 5 groups: Control group (CG), where the buccal branch of the facial nerve was collected; Experimental Suture Group (ESG) and Experimental Fibrin Group (EFG), in which the buccal branch was end-to-side sutured to the zygomatic branch on the right side of the face or coaptated with fibrin sealant on the left side; Experimental Suture Laser Group (ESLG) and Experimental Fibrin Laser Group (EFLG), in which the same procedures were performed as the ESG and EFG, associated with PBMT (wavelength of 830nm, energy density 6.2J/cm 2 , power output 30mW, beam area of 0.116cm 2 , power density 0.26W/cm 2 , total energy per session 2.16J, cumulative dose of 34.56J). The laser was applied for 24s/site at 3 points on the skin's surface, for a total application time of 72s, performed immediately after surgery and 3 times a week for 5weeks. A statistically significant difference was observed in the fiber nerve area between the EFG and EFLG (57.49±3.13 and 62.52±3.56μm 2 , respectively). For the area of the axon, fiber diameter, axon diameter, myelin sheath area and myelin sheath thickness no statistically significant differences were found (p<0.05). The functional recovery of whisker movement occurred faster in the ESLG and EFLG, which were associated with PBMT, with results closer to the CG. Therefore, PBMT accelerated morphological and functional nerve repair in both techniques. Copyright © 2017. Published by Elsevier B.V.

  11. Experimental analysis of mechanical joints strength by means of energy dissipation

    NASA Astrophysics Data System (ADS)

    Wolf, Alexander; Lafarge, Remi; Kühn, Tino; Brosius, Alexander

    2018-05-01

    Designing complex structures with the demand for weight reduction leads directly to a multi-material concept. This mixture has to be joined securely and welding, mechanical joining and the usage of adhesives are commonly used for that purpose. Sometimes also a mix of at least two materials is useful to combine the individual advantages. The challenge is the non-destructive testing of these connections because destructive testing requires a lot of preparation and expensive testing equipment. The authors show a testing method by measuring and analysing the energy dissipation in mechanical joints. Known methods are radiography, thermography and ultrasound testing. Unfortunately, the usage of these methods is difficult and often not usable in fibre-reinforced-plastics. The presented approach measures the propagation of the elastic strain wave through the joint. A defined impact strain is detected with by strain-gauges whereby the transmitter is located on one side of the joint and the receiver on the other, respectively. Because of different mechanisms, energy dissipates by passing the joint areas. Main reasons are damping caused by friction and material specific damping. Insufficient performed joints lead to an effect especially in the friction damping. By the measurement of the different strains and the resulting energy loss a statement to the connection quality is given. The possible defect during the execution of the joint can be identified by the energy loss and strain vs. time curve. After the description of the method, the authors present the results of energy dissipation measurements at a bolted assembly with different locking torques. By the adjustable tightening torques for the screw connections easily a variation of the contact pressure can be applied and analysed afterwards. The outlook will give a statement for the usability for other mechanical joints and fibre-reinforced-plastics.

  12. Integral gas seal for fuel cell gas distribution assemblies and method of fabrication

    DOEpatents

    Dettling, Charles J.; Terry, Peter L.

    1985-03-19

    A porous gas distribution plate assembly for a fuel cell, such as a bipolar assembly, includes an inner impervious region wherein the bipolar assembly has good surface porosity but no through-plane porosity and wherein electrical conductivity through the impervious region is maintained. A hot-pressing process for forming the bipolar assembly includes placing a layer of thermoplastic sealant material between a pair of porous, electrically conductive plates, applying pressure to the assembly at elevated temperature, and allowing the assembly to cool before removing the pressure whereby the layer of sealant material is melted and diffused into the porous plates to form an impervious bond along a common interface between the plates holding the porous plates together. The distribution of sealant within the pores along the surface of the plates provides an effective barrier at their common interface against through-plane transmission of gas.

  13. Method of fabricating an integral gas seal for fuel cell gas distribution assemblies

    DOEpatents

    Dettling, Charles J.; Terry, Peter L.

    1988-03-22

    A porous gas distribution plate assembly for a fuel cell, such as a bipolar assembly, includes an inner impervious region wherein the bipolar assembly has good surface porosity but no through-plane porosity and wherein electrical conductivity through the impervious region is maintained. A hot-pressing process for forming the bipolar assembly includes placing a layer of thermoplastic sealant material between a pair of porous, electrically conductive plates, applying pressure to the assembly at elevated temperature, and allowing the assembly to cool before removing the pressure whereby the layer of sealant material is melted and diffused into the porous plates to form an impervious bond along a common interface between the plates holding the porous plates together. The distribution of sealant within the pores along the surface of the plates provides an effective barrier at their common interface against through-plane transmission of gas.

  14. Joining of advanced materials by superplastic deformation

    DOEpatents

    Goretta, Kenneth C.; Routbort, Jules L.; Gutierrez-Mora, Felipe

    2008-08-19

    A method for utilizing superplastic deformation with or without a novel joint compound that leads to the joining of advanced ceramic materials, intermetallics, and cermets. A joint formed by this approach is as strong as or stronger than the materials joined. The method does not require elaborate surface preparation or application techniques.

  15. Joining of advanced materials by superplastic deformation

    DOEpatents

    Goretta, Kenneth C.; Routbort, Jules L.; Gutierrez-Mora, Felipe

    2005-12-13

    A method for utilizing superplastic deformation with or without a novel joint compound that leads to the joining of advanced ceramic materials, intermetallics, and cermets. A joint formed by this approach is as strong as or stronger than the materials joined. The method does not require elaborate surface preparation or application techniques.

  16. How Many Peripheral Solder Joints in a Surface Mounted Design Experience Inelastic Strains?

    NASA Astrophysics Data System (ADS)

    Suhir, E.; Yi, S.; Ghaffarian, R.

    2017-03-01

    It has been established that it is the peripheral solder joints that are the most vulnerable in the ball-grid-array (BGA) and column-grid-array (CGA) designs and most often fail. As far as the long-term reliability of a soldered microelectronics assembly as a whole is concerned, it makes a difference, if just one or more peripheral joints experience inelastic strains. It is clear that the low cycle fatigue lifetime of the solder system is inversely proportional to the number of joints that simultaneously experience inelastic strains. A simple and physically meaningful analytical expression (formula) is obtained for the prediction, at the design stage, of the number of such joints, if any, for the given effective thermal expansion (contraction) mismatch of the package and PCB; materials and geometrical characteristics of the package/PCB assembly; package size; and, of course, the level of the yield stress in the solder material. The suggested formula can be used to determine if the inelastic strains in the solder material could be avoided by the proper selection of the above characteristics and, if not, how many peripheral joints are expected to simultaneously experience inelastic strains. The general concept is illustrated by a numerical example carried out for a typical BGA package. The suggested analytical model (formula) is applicable to any soldered microelectronics assembly. The roles of other important factors, such as, e.g., solder material anisotropy, grain size, and their random orientation within a joint, are viewed in this analysis as less important factors than the level of the interfacial stress. The roles of these factors will be accounted for in future work and considered, in addition to the location of the joint, in a more complicated, more sophisticated, and more comprehensive reliability/fatigue model.

  17. Joining dissimilar materials using Friction Stir scribe technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upadhyay, Piyush; Hovanski, Yuri; Jana, Saumyadeep

    2016-10-03

    The ability to effectively join materials with vastly different melting points like Aluminum-Steel, Polymer composites - metals has been one of the road blocks in realizing multi-material components for light weighting efforts. Friction stir scribe (FSS) technique is a promising method that produces continuous overlap joint between materials with vastly different melting regimes and high temperature flow characteristics. FSS uses an offset cutting tool at the tip of the FSW pin to create an insitu mechanical interlock between material interfaces. With investments from Vehicle Technology office, US DOE and several automotive manufacturers and suppliers PNNL is developing the FSS processmore » and has demonstrated viability of joining several material combinations. Details of welding trails, unique challenges and mitigation strategies in different material combinations will be discussed. Joint characterization including mechanical tests and joint performances will also be presented.« less

  18. Secure closure of the tracheal incision after natural orifice transluminal endoscopic surgery with a surgical sealant (CoSeal).

    PubMed

    Liu, Yun-Hen; Wu, Yi-Cheng; Chen, Tzu-Ping; Ko, Po-Jen

    2011-09-01

    To evaluate the effectiveness of surgical sealant (CoSeal) in sealing the tracheal assess sites after transtracheal thoracoscopy. Two dogs underwent transtracheal thoracic exploration and pericardial window creation. The thoracic cavity was approached with flexible bronchoscope through a 9-mm tracheal incision. The pericardial window was performed with a needle knife via the working channel of the bronchoscope, and the tracheal assess site was closed with CoSeal using a rubber catheter. The integrity of tracheal healing was evaluated under positive pressure ventilation. Transtracheal creation of pericardial window and closure of tracheal incision with CoSeal was successfully performed in both dogs. There was no evidence of air leaks from the chest tube during positive pressure ventilation. Autopsy revealed no injury to the mediastinum and intrathoracic structure. Endoscopic closure of tracheal access site of NOTES with CoSeal appears to be a feasible technique.

  19. Elasto-Plastic Analysis of Tee Joints Using HOT-SMAC

    NASA Technical Reports Server (NTRS)

    Arnold, Steve M. (Technical Monitor); Bednarcyk, Brett A.; Yarrington, Phillip W.

    2004-01-01

    The Higher Order Theory - Structural/Micro Analysis Code (HOT-SMAC) software package is applied to analyze the linearly elastic and elasto-plastic response of adhesively bonded tee joints. Joints of this type are finding an increasing number of applications with the increased use of composite materials within advanced aerospace vehicles, and improved tools for the design and analysis of these joints are needed. The linearly elastic results of the code are validated vs. finite element analysis results from the literature under different loading and boundary conditions, and new results are generated to investigate the inelastic behavior of the tee joint. The comparison with the finite element results indicates that HOT-SMAC is an efficient and accurate alternative to the finite element method and has a great deal of potential as an analysis tool for a wide range of bonded joints.

  20. Joint Actinide Shock Physics Experimental Research - JASPER

    ScienceCinema

    None

    2018-01-16

    Commonly known as JASPER the Joint Actinide Shock Physics Experimental Research facility is a two stage light gas gun used to study the behavior of plutonium and other materials under high pressures, temperatures, and strain rates.