Sample records for joint soft multiuser

  1. Joint channel estimation and multi-user detection for multipath fading channels in DS-CDMA systems

    NASA Astrophysics Data System (ADS)

    Wu, Sau-Hsuan; Kuo, C.-C. Jay

    2002-11-01

    The technique of joint blind channel estimation and multiple access interference (MAI) suppression for an asynchronous code-division multiple-access (CDMA) system is investigated in this research. To identify and track dispersive time-varying fading channels and to avoid the phase ambiguity that come with the second-order statistic approaches, a sliding-window scheme using the expectation maximization (EM) algorithm is proposed. The complexity of joint channel equalization and symbol detection for all users increases exponentially with system loading and the channel memory. The situation is exacerbated if strong inter-symbol interference (ISI) exists. To reduce the complexity and the number of samples required for channel estimation, a blind multiuser detector is developed. Together with multi-stage interference cancellation using soft outputs provided by this detector, our algorithm can track fading channels with no phase ambiguity even when channel gains attenuate close to zero.

  2. A joint swarm intelligence algorithm for multi-user detection in MIMO-OFDM system

    NASA Astrophysics Data System (ADS)

    Hu, Fengye; Du, Dakun; Zhang, Peng; Wang, Zhijun

    2014-11-01

    In the multi-input multi-output orthogonal frequency division multiplexing (MIMO-OFDM) system, traditional multi-user detection (MUD) algorithms that usually used to suppress multiple access interference are difficult to balance system detection performance and the complexity of the algorithm. To solve this problem, this paper proposes a joint swarm intelligence algorithm called Ant Colony and Particle Swarm Optimisation (AC-PSO) by integrating particle swarm optimisation (PSO) and ant colony optimisation (ACO) algorithms. According to simulation results, it has been shown that, with low computational complexity, the MUD for the MIMO-OFDM system based on AC-PSO algorithm gains comparable MUD performance with maximum likelihood algorithm. Thus, the proposed AC-PSO algorithm provides a satisfactory trade-off between computational complexity and detection performance.

  3. A joint precoding scheme for indoor downlink multi-user MIMO VLC systems

    NASA Astrophysics Data System (ADS)

    Zhao, Qiong; Fan, Yangyu; Kang, Bochao

    2017-11-01

    In this study, we aim to improve the system performance and reduce the implementation complexity of precoding scheme for visible light communication (VLC) systems. By incorporating the power-method algorithm and the block diagonalization (BD) algorithm, we propose a joint precoding scheme for indoor downlink multi-user multi-input-multi-output (MU-MIMO) VLC systems. In this scheme, we apply the BD algorithm to eliminate the co-channel interference (CCI) among users firstly. Secondly, the power-method algorithm is used to search the precoding weight for each user based on the optimal criterion of signal to interference plus noise ratio (SINR) maximization. Finally, the optical power restrictions of VLC systems are taken into account to constrain the precoding weight matrix. Comprehensive computer simulations in two scenarios indicate that the proposed scheme always has better bit error rate (BER) performance and lower computation complexity than that of the traditional scheme.

  4. An Efficient Downlink Scheduling Strategy Using Normal Graphs for Multiuser MIMO Wireless Systems

    NASA Astrophysics Data System (ADS)

    Chen, Jung-Chieh; Wu, Cheng-Hsuan; Lee, Yao-Nan; Wen, Chao-Kai

    Inspired by the success of the low-density parity-check (LDPC) codes in the field of error-control coding, in this paper we propose transforming the downlink multiuser multiple-input multiple-output scheduling problem into an LDPC-like problem using the normal graph. Based on the normal graph framework, soft information, which indicates the probability that each user will be scheduled to transmit packets at the access point through a specified angle-frequency sub-channel, is exchanged among the local processors to iteratively optimize the multiuser transmission schedule. Computer simulations show that the proposed algorithm can efficiently schedule simultaneous multiuser transmission which then increases the overall channel utilization and reduces the average packet delay.

  5. Uplink transmit beamforming design for SINR maximization with full multiuser channel state information

    NASA Astrophysics Data System (ADS)

    Xi, Songnan; Zoltowski, Michael D.

    2008-04-01

    Multiuser multiple-input multiple-output (MIMO) systems are considered in this paper. We continue our research on uplink transmit beamforming design for multiple users under the assumption that the full multiuser channel state information, which is the collection of the channel state information between each of the users and the base station, is known not only to the receiver but also to all the transmitters. We propose an algorithm for designing optimal beamforming weights in terms of maximizing the signal-to-interference-plus-noise ratio (SINR). Through statistical modeling, we decouple the original mathematically intractable optimization problem and achieved a closed-form solution. As in our previous work, the minimum mean-squared error (MMSE) receiver with successive interference cancellation (SIC) is adopted for multiuser detection. The proposed scheme is compared with an existing jointly optimized transceiver design, referred to as the joint transceiver in this paper, and our previously proposed eigen-beamforming algorithm. Simulation results demonstrate that our algorithm, with much less computational burden, accomplishes almost the same performance as the joint transceiver for spatially independent MIMO channel and even better performance for spatially correlated MIMO channels. And it always works better than our previously proposed eigen beamforming algorithm.

  6. Soft tissue balance changes depending on joint distraction force in total knee arthroplasty.

    PubMed

    Nagai, Kanto; Muratsu, Hirotsugu; Matsumoto, Tomoyuki; Miya, Hidetoshi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2014-03-01

    The influence of joint distraction force on intraoperative soft tissue balance was evaluated using Offset Repo-Tensor® for 78 knees that underwent primary posterior-stabilized total knee arthroplasty. The joint center gap and varus ligament balance were measured between osteotomized surfaces using 20, 40 and 60 lbs of joint distraction force. These values were significantly increased at extension and flexion as the distraction force increased. Furthermore, lateral compartment stiffness was significantly lower than medial compartment stiffness. Thus, larger joint distraction forces led to larger varus ligament balance and joint center gap, because of the difference in soft tissue stiffness between lateral and medial compartments. These findings indicate the importance of the strength of joint distraction force in the assessment of soft tissue balance, especially when using gap-balancing technique. © 2014.

  7. Distributed Compressive CSIT Estimation and Feedback for FDD Multi-User Massive MIMO Systems

    NASA Astrophysics Data System (ADS)

    Rao, Xiongbin; Lau, Vincent K. N.

    2014-06-01

    To fully utilize the spatial multiplexing gains or array gains of massive MIMO, the channel state information must be obtained at the transmitter side (CSIT). However, conventional CSIT estimation approaches are not suitable for FDD massive MIMO systems because of the overwhelming training and feedback overhead. In this paper, we consider multi-user massive MIMO systems and deploy the compressive sensing (CS) technique to reduce the training as well as the feedback overhead in the CSIT estimation. The multi-user massive MIMO systems exhibits a hidden joint sparsity structure in the user channel matrices due to the shared local scatterers in the physical propagation environment. As such, instead of naively applying the conventional CS to the CSIT estimation, we propose a distributed compressive CSIT estimation scheme so that the compressed measurements are observed at the users locally, while the CSIT recovery is performed at the base station jointly. A joint orthogonal matching pursuit recovery algorithm is proposed to perform the CSIT recovery, with the capability of exploiting the hidden joint sparsity in the user channel matrices. We analyze the obtained CSIT quality in terms of the normalized mean absolute error, and through the closed-form expressions, we obtain simple insights into how the joint channel sparsity can be exploited to improve the CSIT recovery performance.

  8. Articular soft tissue anatomy of the archosaur hip joint: Structural homology and functional implications.

    PubMed

    Tsai, Henry P; Holliday, Casey M

    2015-06-01

    Archosaurs evolved a wide diversity of locomotor postures, body sizes, and hip joint morphologies. The two extant archosaurs clades (birds and crocodylians) possess highly divergent hip joint morphologies, and the homologies and functions of their articular soft tissues, such as ligaments, cartilage, and tendons, are poorly understood. Reconstructing joint anatomy and function of extinct vertebrates is critical to understanding their posture, locomotor behavior, ecology, and evolution. However, the lack of soft tissues in fossil taxa makes accurate inferences of joint function difficult. Here, we describe the soft tissue anatomies and their osteological correlates in the hip joint of archosaurs and their sauropsid outgroups, and infer structural homology across the extant taxa. A comparative sample of 35 species of birds, crocodylians, lepidosaurs, and turtles ranging from hatchling to skeletally mature adult were studied using dissection, imaging, and histology. Birds and crocodylians possess topologically and histologically consistent articular soft tissues in their hip joints. Epiphyseal cartilages, fibrocartilages, and ligaments leave consistent osteological correlates. The archosaur acetabulum possesses distinct labrum and antitrochanter structures on the supraacetabulum. The ligamentum capitis femoris consists of distinct pubic- and ischial attachments, and is homologous with the ventral capsular ligament of lepidosaurs. The proximal femur has a hyaline cartilage core attached to the metaphysis via a fibrocartilaginous sleeve. This study provides new insight into soft tissue structures and their osteological correlates (e.g., the antitrochanter, the fovea capitis, and the metaphyseal collar) in the archosaur hip joint. The topological arrangement of fibro- and hyaline cartilage may provide mechanical support for the chondroepiphysis. The osteological correlates identified here will inform systematic and functional analyses of archosaur hindlimb evolution and

  9. Multi-use lunar telescopes

    NASA Technical Reports Server (NTRS)

    Drummond, Mark; Hine, Butler; Genet, Russell; Genet, David; Talent, David; Boyd, Louis; Trueblood, Mark; Filippenko, Alexei V. (Editor)

    1991-01-01

    The objective of multi-use telescopes is to reduce the initial and operational costs of space telescopes to the point where a fair number of telescopes, a dozen or so, would be affordable. The basic approach is to develop a common telescope, control system, and power and communications subsystem that can be used with a wide variety of instrument payloads, i.e., imaging CCD cameras, photometers, spectrographs, etc. By having such a multi-use and multi-user telescope, a common practice for earth-based telescopes, development cost can be shared across many telescopes, and the telescopes can be produced in economical batches.

  10. Multiuse trail intersection safety analysis: A crowdsourced data perspective.

    PubMed

    Jestico, Ben; Nelson, Trisalyn A; Potter, Jason; Winters, Meghan

    2017-06-01

    Real and perceived concerns about cycling safety are a barrier to increased ridership in many cities. Many people prefer to bike on facilities separated from motor vehicles, such as multiuse trails. However, due to underreporting, cities lack data on bike collisions, especially along greenways and multiuse paths. We used a crowdsourced cycling incident dataset (2005-2016) from BikeMaps.org for the Capital Regional District (CRD), BC, Canada. Our goal was to identify design characteristics associated with unsafe intersections between multiuse trails and roads. 92.8% of mapped incidents occurred between 2014 and 2016. We extracted both collision and near miss incidents at intersections from BikeMaps.org. We conducted site observations at 32 intersections where a major multiuse trail intersected with roads. We compared attributes of reported incidents at multiuse trail-road intersections to those at road-road intersections. We then used negative binomial regression to model the relationship between the number of incidents and the infrastructure characteristics at multiuse trail-road intersections. We found a higher proportion of collisions (38%, or 17/45 total reports) at multiuse trail-road intersections compared to road-road intersections (23%, or 62/268 total reports). A higher proportion of incidents resulted in an injury at multiuse trail-road intersections compared to road-road intersections (33% versus 15%). Cycling volumes, vehicle volumes, and trail sight distance were all associated with incident frequency at multiuse trail-road intersections. Supplementing traditional crash records with crowdsourced cycling incident data provides valuable evidence on cycling safety at intersections between multiuse trails and roads, and more generally, when conflicts occur between diverse transportation modes. Copyright © 2017. Published by Elsevier Ltd.

  11. Robust Control of a Cable-Driven Soft Exoskeleton Joint for Intrinsic Human-Robot Interaction.

    PubMed

    Jarrett, C; McDaid, A J

    2017-07-01

    A novel, cable-driven soft joint is presented for use in robotic rehabilitation exoskeletons to provide intrinsic, comfortable human-robot interaction. The torque-displacement characteristics of the soft elastomeric core contained within the joint are modeled. This knowledge is used in conjunction with a dynamic system model to derive a sliding mode controller (SMC) to implement low-level torque control of the joint. The SMC controller is experimentally compared with a baseline feedback-linearised proportional-derivative controller across a range of conditions and shown to be robust to un-modeled disturbances. The torque controller is then tested with six healthy subjects while they perform a selection of activities of daily living, which has validated its range of performance. Finally, a case study with a participant with spastic cerebral palsy is presented to illustrate the potential of both the joint and controller to be used in a physiotherapy setting to assist clinical populations.

  12. Soft tissue distraction using pentagonal frame for long-standing traumatic flexion deformity of interphalangeal joints.

    PubMed

    Nazerani, Shaharm; Keramati, Mohammad Reza; Vahedian, Jalal; Fereshtehnejad, Seyed-Mohammad

    2012-01-01

    Interphalangeal joint contracture is a challenging complication of hand trauma, which reduces the functional capacity of the entire hand. In this study we evaluated the results of soft tissue distraction with no collateral ligament transection or volar plate removal in comparison with traditional operation of contracture release and partial ligament transection and volar plate removal. In this prospective study, a total of 40 patients in two equal groups (A and B) were studied. Patients suffering from chronic flexion contracture of abrasive traumatic nature were included. Group A were treated by soft tissue distraction using pentagonal frame technique and in Group B the contracture release was followed by finger splinting. Analyzed data revealed a significant difference between the two groups for range of motion in the proximal interphalangeal joints (P less than 0.05), while it was not meaningful in the distal interphalangeal joints (P larger than 0.05). There was not a significant difference in the degrees of flexion contracture between groups (P larger than 0.05). Regression analysis showed that using pentagonal frame technique significantly increased the mean improvement in range of motion of proximal interphalangeal joints (P less than 0.001), while the higher the preoperative flexion contracture was observed in proximal interphalangeal joints, the lower improvement was achieved in range of motion of proximal interphalangeal joints after intervention (P less than 0.001). Soft tissue distraction using pentagonal frame technique with gradual and continuous collateral ligament and surrounding joint tissues distraction combined with skin Z-plasty significantly improves the range of motion in patients with chronic traumatic flexion deformity of proximal and/or distal interphalangeal joints.

  13. Can joint sound assess soft and hard endpoints of the Lachman test?: A preliminary study.

    PubMed

    Hattori, Koji; Ogawa, Munehiro; Tanaka, Kazunori; Matsuya, Ayako; Uematsu, Kota; Tanaka, Yasuhito

    2016-05-12

    The Lachman test is considered to be a reliable physical examination for anterior cruciate ligament (ACL) injury. Patients with a damaged ACL demonstrate a soft endpoint feeling. However, examiners judge the soft and hard endpoints subjectively. The purpose of our study was to confirm objective performance of the Lachman test using joint auscultation. Human and porcine knee joints were examined. Knee joint sound during the Lachman test (Lachman sound) was analyzed by fast Fourier transformation. As quantitative indices of Lachman sound, the peak sound as the maximum relative amplitude (acoustic pressure) and its frequency were used. The mean Lachman peak sound for healthy volunteer knees was 86.9 ± 12.9 Hz in frequency and -40 ± 2.5 dB in acoustic pressure. The mean Lachman peak sound for intact porcine knees was 84.1 ± 9.4 Hz and -40.5 ± 1.7 dB. Porcine knees with ACL deficiency had a soft endpoint feeling during the Lachman test. The Lachman peak sounds of porcine knees with ACL deficiency were dispersed into four distinct groups, with center frequencies of around 40, 160, 450, and 1600. The Lachman peak sound was capable of assessing soft and hard endpoints of the Lachman test objectively.

  14. Differential Characteristics Based Iterative Multiuser Detection for Wireless Sensor Networks

    PubMed Central

    Chen, Xiaoguang; Jiang, Xu; Wu, Zhilu; Zhuang, Shufeng

    2017-01-01

    High throughput, low latency and reliable communication has always been a hot topic for wireless sensor networks (WSNs) in various applications. Multiuser detection is widely used to suppress the bad effect of multiple access interference in WSNs. In this paper, a novel multiuser detection method based on differential characteristics is proposed to suppress multiple access interference. The proposed iterative receive method consists of three stages. Firstly, a differential characteristics function is presented based on the optimal multiuser detection decision function; then on the basis of differential characteristics, a preliminary threshold detection is utilized to find the potential wrongly received bits; after that an error bit corrector is employed to correct the wrong bits. In order to further lower the bit error ratio (BER), the differential characteristics calculation, threshold detection and error bit correction process described above are iteratively executed. Simulation results show that after only a few iterations the proposed multiuser detection method can achieve satisfactory BER performance. Besides, BER and near far resistance performance are much better than traditional suboptimal multiuser detection methods. Furthermore, the proposed iterative multiuser detection method also has a large system capacity. PMID:28212328

  15. University multi-user facility survey-2010.

    PubMed

    Riley, Melissa B

    2011-12-01

    Multi-user facilities serve as a resource for many universities. In 2010, a survey was conducted investigating possible changes and successful characteristics of multi-user facilities, as well as identifying problems in facilities. Over 300 surveys were e-mailed to persons identified from university websites as being involved with multi-user facilities. Complete responses were received from 36 facilities with an average of 20 years of operation. Facilities were associated with specific departments (22%), colleges (22%), and university research centers (8.3%) or were not affiliated with any department or college within the university (47%). The five most important factors to succeed as a multi-user facility were: 1) maintaining an experienced, professional staff in an open atmosphere; 2) university-level support providing partial funding; 3) broad client base; 4) instrument training programs; and 5) an effective leader and engaged strategic advisory group. The most significant problems were: 1) inadequate university financial support and commitment; 2) problems recovering full service costs from university subsidies and user fees; 3) availability of funds to repair and upgrade equipment; 4) inability to retain highly qualified staff; and 5) unqualified users dirtying/damaging equipment. Further information related to these issues and to fee structure was solicited. Overall, there appeared to be a decline in university support for facilities and more emphasis on securing income by serving clients outside of the institution and by obtaining grants from entities outside of the university.

  16. Code-division multiple-access multiuser demodulator by using quantum fluctuations.

    PubMed

    Otsubo, Yosuke; Inoue, Jun-Ichi; Nagata, Kenji; Okada, Masato

    2014-07-01

    We examine the average-case performance of a code-division multiple-access (CDMA) multiuser demodulator in which quantum fluctuations are utilized to demodulate the original message within the context of Bayesian inference. The quantum fluctuations are built into the system as a transverse field in the infinite-range Ising spin glass model. We evaluate the performance measurements by using statistical mechanics. We confirm that the CDMA multiuser modulator using quantum fluctuations achieve roughly the same performance as the conventional CDMA multiuser modulator through thermal fluctuations on average. We also find that the relationship between the quality of the original information retrieval and the amplitude of the transverse field is somehow a "universal feature" in typical probabilistic information processing, viz., in image restoration, error-correcting codes, and CDMA multiuser demodulation.

  17. Code-division multiple-access multiuser demodulator by using quantum fluctuations

    NASA Astrophysics Data System (ADS)

    Otsubo, Yosuke; Inoue, Jun-ichi; Nagata, Kenji; Okada, Masato

    2014-07-01

    We examine the average-case performance of a code-division multiple-access (CDMA) multiuser demodulator in which quantum fluctuations are utilized to demodulate the original message within the context of Bayesian inference. The quantum fluctuations are built into the system as a transverse field in the infinite-range Ising spin glass model. We evaluate the performance measurements by using statistical mechanics. We confirm that the CDMA multiuser modulator using quantum fluctuations achieve roughly the same performance as the conventional CDMA multiuser modulator through thermal fluctuations on average. We also find that the relationship between the quality of the original information retrieval and the amplitude of the transverse field is somehow a "universal feature" in typical probabilistic information processing, viz., in image restoration, error-correcting codes, and CDMA multiuser demodulation.

  18. Soft Smart Garments for Lower Limb Joint Position Analysis.

    PubMed

    Totaro, Massimo; Poliero, Tommaso; Mondini, Alessio; Lucarotti, Chiara; Cairoli, Giovanni; Ortiz, Jesùs; Beccai, Lucia

    2017-10-12

    Revealing human movement requires lightweight, flexible systems capable of detecting mechanical parameters (like strain and pressure) while being worn comfortably by the user, and not interfering with his/her activity. In this work we address such multifaceted challenge with the development of smart garments for lower limb motion detection, like a textile kneepad and anklet in which soft sensors and readout electronics are embedded for retrieving movement of the specific joint. Stretchable capacitive sensors with a three-electrode configuration are built combining conductive textiles and elastomeric layers, and distributed around knee and ankle. Results show an excellent behavior in the ~30% strain range, hence the correlation between sensors' responses and the optically tracked Euler angles is allowed for basic lower limb movements. Bending during knee flexion/extension is detected, and it is discriminated from any external contact by implementing in real time a low computational algorithm. The smart anklet is designed to address joint motion detection in and off the sagittal plane. Ankle dorsi/plantar flexion, adduction/abduction, and rotation are retrieved. Both knee and ankle smart garments show a high accuracy in movement detection, with a RMSE less than 4° in the worst case.

  19. Soft Smart Garments for Lower Limb Joint Position Analysis

    PubMed Central

    Totaro, Massimo; Poliero, Tommaso; Mondini, Alessio; Lucarotti, Chiara; Cairoli, Giovanni; Ortiz, Jesùs; Beccai, Lucia

    2017-01-01

    Revealing human movement requires lightweight, flexible systems capable of detecting mechanical parameters (like strain and pressure) while being worn comfortably by the user, and not interfering with his/her activity. In this work we address such multifaceted challenge with the development of smart garments for lower limb motion detection, like a textile kneepad and anklet in which soft sensors and readout electronics are embedded for retrieving movement of the specific joint. Stretchable capacitive sensors with a three-electrode configuration are built combining conductive textiles and elastomeric layers, and distributed around knee and ankle. Results show an excellent behavior in the ~30% strain range, hence the correlation between sensors’ responses and the optically tracked Euler angles is allowed for basic lower limb movements. Bending during knee flexion/extension is detected, and it is discriminated from any external contact by implementing in real time a low computational algorithm. The smart anklet is designed to address joint motion detection in and off the sagittal plane. Ankle dorsi/plantar flexion, adduction/abduction, and rotation are retrieved. Both knee and ankle smart garments show a high accuracy in movement detection, with a RMSE less than 4° in the worst case. PMID:29023365

  20. The in vivo plantar soft tissue mechanical property under the metatarsal head: implications of tissues׳ joint-angle dependent response in foot finite element modeling.

    PubMed

    Chen, Wen-Ming; Lee, Sung-Jae; Lee, Peter Vee Sin

    2014-12-01

    Material properties of the plantar soft tissue have not been well quantified in vivo (i.e., from life subjects) nor for areas other than the heel pad. This study explored an in vivo investigation of the plantar soft tissue material behavior under the metatarsal head (MTH). We used a novel device collecting indentation data at controlled metatarsophalangeal joint angles. Combined with inverse analysis, tissues׳ joint-angle dependent material properties were identified. The results showed that the soft tissue under MTH exhibited joint-angle dependent material responses, and the computed parameters using the Ogden material model were 51.3% and 30.9% larger in the dorsiflexed than in the neutral positions, respectively. Using derived parameters in subject-specific foot finite element models revealed only those models that used tissues׳ joint-dependent responses could reproduce the known plantar pressure pattern under the MTH. It is suggested that, to further improve specificity of the personalized foot finite element models, quantitative mechanical properties of the tissue inclusive of the effects of metatarsophalangeal joint dorsiflexion are needed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Systematic Quantification of Stabilizing Effects of Subtalar Joint Soft-Tissue Constraints in a Novel Cadaveric Model.

    PubMed

    Pellegrini, Manuel J; Glisson, Richard R; Wurm, Markus; Ousema, Paul H; Romash, Michael M; Nunley, James A; Easley, Mark E

    2016-05-18

    Distinguishing between ankle instability and subtalar joint instability is challenging because the contributions of the subtalar joint's soft-tissue constraints are poorly understood. This study quantified the effects on joint stability of systematic sectioning of these constraints followed by application of torsional and drawer loads simulating a manual clinical examination. Subtalar joint motion in response to carefully controlled inversion, eversion, internal rotation, and external rotation moments and multidirectional drawer forces was quantified in fresh-frozen cadaver limbs. Sequential measurements were obtained under axial load approximating a non-weight-bearing clinical setting with the foot in neutral, 10° of dorsiflexion, and 10° and 20° of plantar flexion. The contributions of the components of the inferior extensor retinaculum were documented after incremental sectioning. The calcaneofibular, cervical, and interosseous talocalcaneal ligaments were then sectioned sequentially, in two different orders, to produce five different ligament-insufficiency scenarios. Incremental detachment of the components of the inferior extensor retinaculum had no effect on subtalar motion independent of foot position. Regardless of the subsequent ligament-sectioning order, significant motion increases relative to the intact condition occurred only after transection of the calcaneofibular ligament. Sectioning of this ligament produced increased inversion and external rotation, which was most evident with the foot dorsiflexed. Calcaneofibular ligament disruption results in increases in subtalar inversion and external rotation that might be detectable during a manual examination. Insufficiency of other subtalar joint constraints may result in motion increases that are too subtle to be perceptible. If calcaneofibular ligament insufficiency is established, its reconstruction or repair should receive priority over that of other ankle or subtalar periarticular soft

  2. Multi-User Hardware Solutions to Combustion Science ISS Research

    NASA Technical Reports Server (NTRS)

    Otero, Angel M.

    2001-01-01

    In response to the budget environment and to expand on the International Space Station (ISS) Fluids and Combustion Facility (FCF) Combustion Integrated Rack (CIR), common hardware approach, the NASA Combustion Science Program shifted focus in 1999 from single investigator PI (Principal Investigator)-specific hardware to multi-user 'Minifacilities'. These mini-facilities would take the CIR common hardware philosophy to the next level. The approach that was developed re-arranged all the investigations in the program into sub-fields of research. Then common requirements within these subfields were used to develop a common system that would then be complemented by a few PI-specific components. The sub-fields of research selected were droplet combustion, solids and fire safety, and gaseous fuels. From these research areas three mini-facilities have sprung: the Multi-user Droplet Combustion Apparatus (MDCA) for droplet research, Flow Enclosure for Novel Investigations in Combustion of Solids (FEANICS) for solids and fire safety, and the Multi-user Gaseous Fuels Apparatus (MGFA) for gaseous fuels. These mini-facilities will develop common Chamber Insert Assemblies (CIA) and diagnostics for the respective investigators complementing the capability provided by CIR. Presently there are four investigators for MDCA, six for FEANICS, and four for MGFA. The goal of these multi-user facilities is to drive the cost per PI down after the initial development investment is made. Each of these mini-facilities will become a fixture of future Combustion Science NASA Research Announcements (NRAs), enabling investigators to propose against an existing capability. Additionally, an investigation is provided the opportunity to enhance the existing capability to bridge the gap between the capability and their specific science requirements. This multi-user development approach will enable the Combustion Science Program to drive cost per investigation down while drastically reducing the time

  3. Usability testing of a prototype multi-user telehealth kiosk.

    PubMed

    Courtney, Karen L; Matthews, Judith T; McMillan, Julie M; Person Mecca, Laurel; Smailagic, Asim; Siewiorek, Daniel

    2015-01-01

    The overall purpose of this study was to learn how community-dwelling older adults would interact with our prototype multi-user telehealth kiosk and their views about its usability. Seven subjects participated in laboratory-based usability sessions to evaluate the physical design, appearance, functionality and perceived ease of use of a multi-user telehealth kiosk prototype. During usability testing participants recommended 18 new features (29% of comments), identified 15 software errors (23% of comments) and 29 user interface errors (47% of comments).

  4. On Performance of Linear Multiuser Detectors for Wireless Multimedia Applications

    NASA Astrophysics Data System (ADS)

    Agarwal, Rekha; Reddy, B. V. R.; Bindu, E.; Nayak, Pinki

    In this paper, performance of different multi-rate schemes in DS-CDMA system is evaluated. The analysis of multirate linear multiuser detectors with multiprocessing gain is analyzed for synchronous Code Division Multiple Access (CDMA) systems. Variable data rate is achieved by varying the processing gain. Our conclusion is that bit error rate for multirate and single rate systems can be made same with a tradeoff with number of users in linear multiuser detectors.

  5. Proposal for Implementing Multi-User Database (MUD) Technology in an Academic Library.

    ERIC Educational Resources Information Center

    Filby, A. M. Iliana

    1996-01-01

    Explores the use of MOO (multi-user object oriented) virtual environments in academic libraries to enhance reference services. Highlights include the development of multi-user database (MUD) technology from gaming to non-recreational settings; programming issues; collaborative MOOs; MOOs as distinguished from other types of virtual reality; audio…

  6. PVC gel soft actuator-based wearable assist wear for hip joint support during walking

    NASA Astrophysics Data System (ADS)

    Li, Yi; Hashimoto, Minoru

    2017-12-01

    Plasticized polyvinyl chloride (PVC) gel and mesh electrode-based soft actuators have considerable potential to provide new types of artificial muscle, exhibiting similar responsiveness to biological muscle in air, >10% deformation, >90 kPa output stress, variable stiffness, long cycle life (>5 million cycles), and low power consumption. We have designed and fabricated a prototype of walking assist wear using the PVC gel actuator in previous study. The system has several advantages compared with traditional motor-based exoskeletons, including lower weight and power consumption, and no requirement for rigid external structures that constrain the wearer’s joints. In this study, we designed and established a control and power system to making the whole system portable and wearable outdoors. And we designed two control strategies based on the characteristics of the assist wear and the biological kinematics. In a preliminary experimental evaluation, a hemiparetic stroke patient performed a 10 m to-and-fro straight line walking task with and without assist wear on the affected side. We found that the assist wear enabled natural movement, increasing step length and decreasing muscular activity during straight line walking. We demonstrated that the assistance effect could be adjusted by controlling the on-off time of the PVC gel soft actuators. The results show the effectiveness of the proposed system and suggest the feasibility of PVC gel soft actuators for developing practical soft wearable assistive devices, informing the development of future wearable robots and the other soft actuator technologies for human movement assistance and rehabilitation.

  7. Performance Analysis of Iterative Channel Estimation and Multiuser Detection in Multipath DS-CDMA Channels

    NASA Astrophysics Data System (ADS)

    Li, Husheng; Betz, Sharon M.; Poor, H. Vincent

    2007-05-01

    This paper examines the performance of decision feedback based iterative channel estimation and multiuser detection in channel coded aperiodic DS-CDMA systems operating over multipath fading channels. First, explicit expressions describing the performance of channel estimation and parallel interference cancellation based multiuser detection are developed. These results are then combined to characterize the evolution of the performance of a system that iterates among channel estimation, multiuser detection and channel decoding. Sufficient conditions for convergence of this system to a unique fixed point are developed.

  8. Fatigue Magnification Factors of Arc-Soft-Toe Bracket Joints

    NASA Astrophysics Data System (ADS)

    Fu, Qiang; Li, Huajun; Wang, Hongqing; Wang, Shuqing; Li, Dejiang; Li, Qun; Fang, Hui

    2018-06-01

    Arc-soft-toe bracket (ASTB), as a joint structure in the marine structure, is the hot spot with significant stress concentration, therefore, fatigue behavior of ASTBs is an important point of concern in their design. Since macroscopic geometric factors obviously influence the stress flaws in joints, the shapes and sizes of ASTBs should represent the stress distribution around cracks in the hot spots. In this paper, we introduce a geometric magnification factor for reflecting the macroscopic geometric effects of ASTB crack features and construct a 3D finite element model to simulate the distribution of stress intensity factor (SIF) at the crack endings. Sensitivity analyses with respect to the geometric ratio H t / L b , R/ L b , L t / L b are performed, and the relations between the geometric factor and these parameters are presented. A set of parametric equations with respect to the geometric magnification factor is obtained using a curve fitting technique. A nonlinear relationship exists between the SIF and the ratio of ASTB arm to toe length. When the ratio of ASTB arm to toe length reaches a marginal value, the SIF of crack at the ASTB toe is not influenced by ASTB geometric parameters. In addition, the arc shape of the ASTB slope edge can transform the stress flowing path, which significantly affects the SIF at the ASTB toe. A proper method to reduce stress concentration is setting a slope edge arc size equal to the ASTB arm length.

  9. Physiotherapy and lumbar facet joint injections as a combination treatment for chronic low back pain. A narrative review of lumbar facet joint injections, lumbar spinal mobilizations, soft tissue massage and lower back mobility exercises.

    PubMed

    Chambers, Hannah

    2013-06-01

    The aim of this study was to summarize the available evidence on lumbar facet joint injections and the physiotherapy treatments, land-based lower back mobility exercise, soft tissue massage and lumbar spinal mobilizations for chronic low back pain (CLBP). The plausibility of physiotherapy and lumbar facet joint injections as a combination treatment is discussed. Using a systematic process, an online electronic search was performed using key words utilizing all available databases and hand searching reference lists. Using a critical appraisal tool from the Critical Appraisal Skills Programme (CASP), the literature was screened to include primary research. The main aspects of the research were summarized. The evidence for lumbar facet joint injections suggests an overall short-term positive effect on CLBP. Land-based lower back mobility exercise and soft tissue massage appear to have a positive effect on CLBP in the short term and possibly in the longer term. There is insufficient evidence to draw conclusions for lumbar spinal mobilizations. The review indicates that lumbar facet joint injections create a short period when pain is reduced. Physiotherapy treatments including land-based lower back mobility exercise and soft tissue massage may be of benefit during this time to improve the longer-term outcomes of patients with CLBP. It is not possible to make generalizations or firm conclusions. The current review highlights the need for further research. A randomized controlled trial is recommended to assess the impact of physiotherapy in combination with lumbar facet joint injections on CLBP. Copyright © 2013 John Wiley & Sons, Ltd.

  10. The Influence of Joint Distraction Force on the Soft-Tissue Balance Using Modified Gap-Balancing Technique in Posterior-Stabilized Total Knee Arthroplasty.

    PubMed

    Nagai, Kanto; Muratsu, Hirotsugu; Takeoka, Yoshiki; Tsubosaka, Masanori; Kuroda, Ryosuke; Matsumoto, Tomoyuki

    2017-10-01

    During modified gap-balancing technique, there is no consensus on the best method for obtaining appropriate soft-tissue balance and determining the femoral component rotation. Sixty-five varus osteoarthritic patients underwent primary posterior-stabilized total knee arthroplasty using modified gap-balancing technique. The influence of joint distraction force on the soft-tissue balance measurement during the modified gap-balancing technique was evaluated with Offset Repo-Tensor between the osteotomized surfaces at extension, and between femoral posterior condyles and tibial osteotomized surface at flexion of the knee before the resection of femoral posterior condyles. The joint center gap (millimeters) and varus ligament balance (°) were measured under 20, 40, and 60 pounds of joint distraction forces, and the differences in these values at extension and flexion (the value at flexion minus the value at extension) were also calculated. The differences in joint center gap (-6.7, -6.8, and -6.9 mm for 20, 40, and 60 pounds, respectively) and varus ligament balance (3.5°, 3.8°, and 3.8°) at extension and flexion were not significantly different among different joint distraction forces, although the joint center gap and varus ligament balance significantly increased stepwise at extension and flexion as the joint distraction force increased. The difference in joint center gap and varus ligament balance at extension and flexion were consistent even among the different joint distraction forces. This novel index would be useful for the determination of femoral component rotation during the modified gap-balancing technique. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Broken Pieces of Circlage Wire Lying in Soft Tissue Envelope Around Knee Joint: A Case Report and Review of Literature

    PubMed Central

    Kalia, Anoop; Khatri, Kavin; Singh, Jagdeep; Bansal, Kapil; Sagy, Mohammed

    2016-01-01

    Introduction: The migration of circlage wires used in tension band wiring construct of patella fractures in the posterior soft tissue envelope surrounding the knee joint has been rarely reported. Case Presentation: A 60-year-old woman presented to us with pain over medial aspect of right knee joint. She underwent open reduction and internal fixation for a patellar fracture which she sustained 4 years back and subsequently underwent kirschner wire(k wire) removal for the same around 2 years back. X-rays of the knee joint shows that the circlage wire used in tension band construct which was left in place had broken into multiple pieces and was lying in the soft tissue envelope surrounding the knee joint and one piece migrate to the popliteal fossa. On examination patient did not had distal neuro-vascular deficit. The pain of the patient was due to the osteo-arthritic changes in her medial side of knee joint rather than broken wire pieces. Patient was advised to undergo total knee replacement along with subsequent removal of broken wires but patient refused for any type of surgery and is kept on regular follow up Conclusion: This case report summarizes a rare complication resulting from hardware failure used for fixing patella fractures and throws a light on potential unwarned complications due to broken wires along with early recogonition and removal of broken hardware by surgeons. PMID:28116277

  12. Contact forces in the tibiofemoral joint from soft tissue tensions: Implications to soft tissue balancing in total knee arthroplasty.

    PubMed

    Verstraete, Matthias A; Meere, Patrick A; Salvadore, Gaia; Victor, Jan; Walker, Peter S

    2017-06-14

    Proper tension of the knee's soft tissue envelope is important during total knee arthroplasty; incorrect tensioning potentially leads to joint stiffness or instability. The latter remains an important trigger for revision surgery. The use of sensors quantifying the intra-articular loads, allows surgeons to assess the ligament tension at the time of surgery. However, realistic target values are missing. In the framework of this paper, eight non-arthritic cadaveric specimens were tested and the intra-articular loads transferred by the medial and lateral compartment were measured using custom sensor modules. These modules were inserted below the articulating surfaces of the proximal tibia, with the specimens mounted on a test setup that mimics surgical conditions. For both compartments, the highest loads are observed in full extension. While creating knee flexion by lifting the femur and flexing the hip, mean values (standard deviation) of 114N (71N) and 63N (28N) are observed at 0° flexion for the medial and lateral compartment respectively. Upon flexion, both medial and lateral loads decrease with mean values at 90° flexion of 30N (22N) and 6N (5N) respectively. The majority of the load is transmitted through the medial compartment. These observations are linked to the deformation of the medial and lateral collaterals, in addition to the anatomy of the passive soft tissues surrounding the knee. In conclusion, these findings provide tangible clinical guidance in assessing the soft tissue loads when dealing with anatomically designed total knee implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Managing a Safe and Successful Multi-User Spaceport

    NASA Technical Reports Server (NTRS)

    Dacko, Taylor; Ketterer, Kirk; Meade, Phillip

    2016-01-01

    Encouraged by the creation of the Office of Commercial Space Transportation within the U.S. Federal Aviation Administration (FAA) in 1984 and the Commercial Space Act of 1998, the National Aeronautics and Space Administration (NASA) now relies on an extensive network of support from commercial companies and organizations. At NASA's Kennedy Space Center (KSC), this collaboration opens competitive opportunities for launch providers, including repurposing underutilized Shuttle Program resources, constructing new facilities, and utilizing center services and laboratories. The resulting multi-user spaceport fosters diverse activity, though it engenders risk from hazards associated with various spaceflight processing activities. The KSC Safety & Mission Assurance (S&MA) Directorate, in coordination with the center's Spaceport Integration and Center Planning & Development organizations, has developed a novel approach to protect NASA's workforce, critical assets, and the public from hazardous, space-related activity associated with KSC's multi-user spaceport. For NASA KSC S&MA, the transformation to a multi-user spaceport required implementing methods to foster safe and successful commercial activity while resolving challenges involving: Retirement of the Space Shuttle program; Co-location of multiple NASA programs; Relationships between the NASA programs; Complex relationships between NASA programs and commercial partner operations in exclusive-use facilities; Complex relationships between NASA programs and commercial partner operations in shared-use facilities. NASA KSC S&MA challenges were met with long-term planning and solutions involving cooperation with the Spaceport Integration and Services Directorate. This directorate is responsible for managing active commercial partnerships with customer advocacy and services management, providing a dedicated and consistent level of support to a wide array of commercial operations. This paper explores these solutions, their

  14. A Multi-User Remote Academic Laboratory System

    ERIC Educational Resources Information Center

    Barrios, Arquimedes; Panche, Stifen; Duque, Mauricio; Grisales, Victor H.; Prieto, Flavio; Villa, Jose L.; Chevrel, Philippe; Canu, Michael

    2013-01-01

    This article describes the development, implementation and preliminary operation assessment of Multiuser Network Architecture to integrate a number of Remote Academic Laboratories for educational purposes on automatic control. Through the Internet, real processes or physical experiments conducted at the control engineering laboratories of four…

  15. Multi-user Droplet Combustion Apparatus (MDCA) Hardware Replacement

    NASA Image and Video Library

    2013-10-02

    ISS037-E-004956 (2 Oct. 2013) --- NASA astronaut Karen Nyberg, Expedition 37 flight engineer, performs the Multi-user Droplet Combustion Apparatus (MDCA) hardware replacement in the Harmony node of the International Space Station.

  16. Multi-user Droplet Combustion Apparatus (MDCA) Hardware Replacement

    NASA Image and Video Library

    2013-10-02

    ISS037-E-004959 (2 Oct. 2013) --- NASA astronaut Karen Nyberg, Expedition 37 flight engineer, performs the Multi-user Droplet Combustion Apparatus (MDCA) hardware replacement in the Harmony node of the International Space Station.

  17. Sensor-Based Human Activity Recognition in a Multi-user Scenario

    NASA Astrophysics Data System (ADS)

    Wang, Liang; Gu, Tao; Tao, Xianping; Lu, Jian

    Existing work on sensor-based activity recognition focuses mainly on single-user activities. However, in real life, activities are often performed by multiple users involving interactions between them. In this paper, we propose Coupled Hidden Markov Models (CHMMs) to recognize multi-user activities from sensor readings in a smart home environment. We develop a multimodal sensing platform and present a theoretical framework to recognize both single-user and multi-user activities. We conduct our trace collection done in a smart home, and evaluate our framework through experimental studies. Our experimental result shows that we achieve an average accuracy of 85.46% with CHMMs.

  18. Design of simplified maximum-likelihood receivers for multiuser CPM systems.

    PubMed

    Bing, Li; Bai, Baoming

    2014-01-01

    A class of simplified maximum-likelihood receivers designed for continuous phase modulation based multiuser systems is proposed. The presented receiver is built upon a front end employing mismatched filters and a maximum-likelihood detector defined in a low-dimensional signal space. The performance of the proposed receivers is analyzed and compared to some existing receivers. Some schemes are designed to implement the proposed receivers and to reveal the roles of different system parameters. Analysis and numerical results show that the proposed receivers can approach the optimum multiuser receivers with significantly (even exponentially in some cases) reduced complexity and marginal performance degradation.

  19. Network coding multiuser scheme for indoor visible light communications

    NASA Astrophysics Data System (ADS)

    Zhang, Jiankun; Dang, Anhong

    2017-12-01

    Visible light communication (VLC) is a unique alternative for indoor data transfer and developing beyond point-to-point. However, for realizing high-capacity networks, VLC is facing challenges including the constrained bandwidth of the optical access point and random occlusion. A network coding scheme for VLC (NC-VLC) is proposed, with increased throughput and system robustness. Based on the Lambertian illumination model, theoretical decoding failure probability of the multiuser NC-VLC system is derived, and the impact of the system parameters on the performance is analyzed. Experiments demonstrate the proposed scheme successfully in the indoor multiuser scenario. These results indicate that the NC-VLC system shows a good performance under the link loss and random occlusion.

  20. The Lateral Proximal Phalanx Flap for Contractures and Soft Tissue Defects in the Proximal Interphalangeal Joint

    PubMed Central

    Beltrán, Aldo G.; Romero, Camilo J.

    2016-01-01

    Background: The management of contractures and soft tissue defects in the proximal interphalangeal (PIP) finger joint remains a challenge. We report a transposition flap from the lateral skin of the proximal phalanx that is based on perforating branches of the digital arteries and can be used safely for both palmar and dorsal cover defects. Methods: We first completed an anatomic study, dissecting 20 fingers in fresh cadavers with arterial injections and made the new flap in patients with dorsal or palmar defects in PIP joints. Results: In cadavers, we can reveal 4 constant branches from each digital artery in the proximal phalanx, with the more distal just in the PIP joint constituting the flap pedicle. Between February 2010 and February 2015, we designed 33 flaps in 29 patients, 7 for dorsal and 26 for palmar defects, with no instances of flap necrosis and 4 distal epidermolysis. The patients were between 4 and 69 years with no major complications, and all of the skin defects in the PIP joint were resolved satisfactorily without any relevant sequelae at the donor site. Conclusions: This flap procedure is an easy, reliable, versatile, and safe technique, and could be an important tool for the management of difficult skin defects and contractures at the PIP joint level. PMID:28082850

  1. Architectures for Developing Multiuser, Immersive Learning Scenarios

    ERIC Educational Resources Information Center

    Nadolski, Rob J.; Hummel, Hans G. K.; Slootmaker, Aad; van der Vegt, Wim

    2012-01-01

    Multiuser immersive learning scenarios hold strong potential for lifelong learning as they can support the acquisition of higher order skills in an effective, efficient, and attractive way. Existing virtual worlds, game development platforms, and game engines only partly cater for the proliferation of such learning scenarios as they are often…

  2. The Fluids And Combustion Facility Combustion Integrated Rack And The Multi-User Droplet Combustion Apparatus: Microgravity Combustion Science Using Modular Multi-User Hardware

    NASA Technical Reports Server (NTRS)

    OMalley, Terence F.; Myhre, Craig A.

    2000-01-01

    The Fluids and Combustion Facility (FCF) is a multi-rack payload planned for the International Space Station (ISS) that will enable the study of fluid physics and combustion science in a microgravity environment. The Combustion Integrated Rack (CIR) is one of two International Standard Payload Racks of the FCF and is being designed primarily to support combustion science experiments. The Multi-user Droplet Combustion Apparatus (MDCA) is a multi-user apparatus designed to accommodate four different droplet combustion science experiments and is the first payload for CIR. The CIR will function independently until the later launch of the Fluids Integrated Rack component of the FCF. This paper provides an overview of the capabilities and the development status of the CIR and MDCA.

  3. Privacy and Security in Multi-User Health Kiosks

    PubMed Central

    TAKYI, HAROLD; WATZLAF, VALERIE; MATTHEWS, JUDITH TABOLT; ZHOU, LEMING; DEALMEIDA, DILHARI

    2017-01-01

    Enforcement of the Health Insurance Portability and Accountability Act (HIPAA) and the Health Information Technology for Economic and Clinical Health Act (HITECH) has gotten stricter and penalties have become more severe in response to a significant increase in computer-related information breaches in recent years. With health information said to be worth twice as much as other forms of information on the underground market, making preservation of privacy and security an integral part of health technology development, rather than an afterthought, not only mitigates risks but also helps to ensure HIPAA and HITECH compliance. This paper provides a guide, based on the Office for Civil Rights (OCR) audit protocol, for creating and maintaining an audit checklist for multi-user health kiosks. Implementation of selected audit elements for a multi-user health kiosk designed for use by community-residing older adults illustrates how the guide can be applied. PMID:28814990

  4. Hip joint injection

    MedlinePlus

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  5. Automatic Bluetooth testing for mobile multi-user applications

    NASA Astrophysics Data System (ADS)

    Luck, Dennis; Hörning, Henrik; Edlich, Stefan

    2008-02-01

    In this paper we present a simple approach for the development of multiuser and multimedia applications based on Bluetooth. One main obstacle for Bluetooth synchronization of mobile applications is the lack of a complete specification implementation. Nowadays these applications must be on market as fast as possible. Hence, developers must be able to test several dozens of mobile devices for their Bluetooth capability. And surprisingly, the capabilities differ not only between the Bluetooth specification 1.0 and 2.0. The current development was triggered by the development of mass applications as mobile multiuser games (e.g. Tetris). Our Application can be distributed on several mobile phones. If started, the Bluetooth applications try to connect each other and automatically start to detect device capabilities. These capabilities will be gathered and distributed to a server. The server performs statistical investigations and aggregates them to be presented as a report. The result is a faster development regarding mobile communications.

  6. A Multi-User Microcomputer System for Small Libraries.

    ERIC Educational Resources Information Center

    Leggate, Peter

    1988-01-01

    Describes the development of Bookshelf, a multi-user microcomputer system for small libraries that uses an integrated software package. The discussion covers the design parameters of the package, which were based on a survey of seven small libraries, and some characteristics of the software. (three notes with references) (CLB)

  7. Research on multi-user encrypted search scheme in cloud environment

    NASA Astrophysics Data System (ADS)

    Yu, Zonghua; Lin, Sui

    2017-05-01

    Aiming at the existing problems of multi-user encrypted search scheme in cloud computing environment, a basic multi-user encrypted scheme is proposed firstly, and then the basic scheme is extended to an anonymous hierarchical management authority. Compared with most of the existing schemes, the scheme not only to achieve the protection of keyword information, but also to achieve the protection of user identity privacy; the same time, data owners can directly control the user query permissions, rather than the cloud server. In addition, through the use of a special query key generation rules, to achieve the hierarchical management of the user's query permissions. The safety analysis shows that the scheme is safe and that the performance analysis and experimental data show that the scheme is practicable.

  8. RACOON: a multiuser QoS design for mobile wireless body area networks.

    PubMed

    Cheng, Shihheng; Huang, Chingyao; Tu, Chun Chen

    2011-10-01

    In this study, Random Contention-based Resource Allocation (RACOON) medium access control (MAC) protocol is proposed to support the quality of service (QoS) for multi-user mobile wireless body area networks (WBANs). Different from existing QoS designs that focus on a single WBAN, a multiuser WBAN QoS should further consider both inter-WBAN interference and inter-WBAN priorities. Similar problems have been studied in both overlapped wireless local area networks (WLANs) and Bluetooth piconets that need QoS supports. However, these solutions are designed for non-medical transmissions that do not consider any priority scheme for medical applications. Most importantly, these studies focus on only static or low mobility networks. Network mobility of WBANs will introduce unnecessary inter-network collisions and energy waste, which are not considered by these solutions. The proposed multiuser-QoS protocol, RACOON, simultaneously satisfies the inter WBAN QoS requirements and overcomes the performance degradation caused by WBAN mobility. Simulation results verify that RACOON provides better latency and energy control, as compared with WBAN QoS protocols without considering the inter-WBAN requirements.

  9. MATCON MODIFIED ASPHALT CONTAINMENT SYSTEM FOR MULTI-USE BROWNFIELDS

    EPA Science Inventory

    The concept of putting brownfield real estate back into safe and practical use is very appealing o both the owner and the neighborhood. Environmental regulations often preclude multi-use alterantives because traditional containment solutions rely on water barrier covers. These ar...

  10. Multiuser receiver for DS-CDMA signals in multipath channels: an enhanced multisurface method.

    PubMed

    Mahendra, Chetan; Puthusserypady, Sadasivan

    2006-11-01

    This paper deals with the problem of multiuser detection in direct-sequence code-division multiple-access (DS-CDMA) systems in multipath environments. The existing multiuser detectors can be divided into two categories: (1) low-complexity poor-performance linear detectors and (2) high-complexity good-performance nonlinear detectors. In particular, in channels where the orthogonality of the code sequences is destroyed by multipath, detectors with linear complexity perform much worse than the nonlinear detectors. In this paper, we propose an enhanced multisurface method (EMSM) for multiuser detection in multipath channels. EMSM is an intermediate piecewise linear detection scheme with a run-time complexity linear in the number of users. Its bit error rate performance is compared with existing linear detectors, a nonlinear radial basis function detector trained by the new support vector learning algorithm, and Verdu's optimal detector. Simulations in multipath channels, for both synchronous and asynchronous cases, indicate that it always outperforms all other linear detectors, performing nearly as well as nonlinear detectors.

  11. A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking.

    PubMed

    Panizzolo, Fausto A; Galiana, Ignacio; Asbeck, Alan T; Siviy, Christopher; Schmidt, Kai; Holt, Kenneth G; Walsh, Conor J

    2016-05-12

    Carrying load alters normal walking, imposes additional stress to the musculoskeletal system, and results in an increase in energy consumption and a consequent earlier onset of fatigue. This phenomenon is largely due to increased work requirements in lower extremity joints, in turn requiring higher muscle activation. The aim of this work was to assess the biomechanical and physiological effects of a multi-joint soft exosuit that applies assistive torques to the biological hip and ankle joints during loaded walking. The exosuit was evaluated under three conditions: powered (EXO_ON), unpowered (EXO_OFF) and unpowered removing the equivalent mass of the device (EXO_OFF_EMR). Seven participants walked on an instrumented split-belt treadmill and carried a load equivalent to 30 % their body mass. We assessed their metabolic cost of walking, kinetics, kinematics, and lower limb muscle activation using a portable gas analysis system, motion capture system, and surface electromyography. Our results showed that the exosuit could deliver controlled forces to a wearer. Net metabolic power in the EXO_ON condition (7.5 ± 0.6 W kg(-1)) was 7.3 ± 5.0 % and 14.2 ± 6.1 % lower than in the EXO_OFF_EMR condition (7.9 ± 0.8 W kg(-1); p = 0.027) and in the EXO_OFF condition (8.5 ± 0.9 W kg(-1); p = 0.005), respectively. The exosuit also reduced the total joint positive biological work (sum of hip, knee and ankle) when comparing the EXO_ON condition (1.06 ± 0.16 J kg(-1)) with respect to the EXO_OFF condition (1.28 ± 0.26 J kg(-1); p = 0.020) and to the EXO_OFF_EMR condition (1.22 ± 0.21 J kg(-1); p = 0.007). The results of the present work demonstrate for the first time that a soft wearable robot can improve walking economy. These findings pave the way for future assistive devices that may enhance or restore gait in other applications.

  12. MDCA (Multi-user Drop Combustion Apparatus) operations

    NASA Image and Video Library

    2009-05-12

    ISS019-E-015912 (12 May 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 19/20 flight engineer, works on the Combustion Integrated Rack (CIR) Multi-user Drop Combustion Apparatus (MDCA) in the Destiny laboratory of the International Space Station. Wakata removed and replaced one fuel reservoir, which required temporary opening the front end cap and removing the fuel supply bypass Quick Disconnect (QD).

  13. MDCA (Multi-user Drop Combustion Apparatus) operations

    NASA Image and Video Library

    2009-05-12

    ISS019-E-015906 (12 May 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 19/20 flight engineer, works on the Combustion Integrated Rack (CIR) Multi-user Drop Combustion Apparatus (MDCA) in the Destiny laboratory of the International Space Station. Wakata removed and replaced one fuel reservoir, which required temporary opening the front end cap and removing the fuel supply bypass Quick Disconnect (QD).

  14. MDCA (Multi-user Drop Combustion Apparatus) operations

    NASA Image and Video Library

    2009-05-12

    ISS019-E-015910(12 May 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 19/20 flight engineer, works on the Combustion Integrated Rack (CIR) Multi-user Drop Combustion Apparatus (MDCA) in the Destiny laboratory of the International Space Station. Wakata removed and replaced one fuel reservoir, which required temporary opening the front end cap and removing the fuel supply bypass Quick Disconnect (QD).

  15. Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy.

    PubMed

    Lee, Dae-Hee; Park, Sung-Chul; Park, Hyung-Joon; Han, Seung-Beom

    2016-12-01

    Open-wedge high tibial osteotomy (HTO) cannot always accurately correct limb alignment, resulting in under- or over-correction. This study assessed the relationship between soft tissue laxity of the knee joint and alignment correction in open-wedge HTO. This prospective study involved 85 patients (86 knees) undergoing open-wedge HTO for primary medial osteoarthritis. The mechanical axis (MA), weight-bearing line (WBL) ratio, and joint line convergence angle (JLCA) were measured on radiographs preoperatively and after 6 months, and the differences between the pre- and post-surgery values were calculated. Post-operative WBL ratios of 57-67 % were classified as acceptable correction. WBL ratios <57 and >67 % were classified as under- and over-corrections, respectively. Preoperative JLCA correlated positively with differences in MA (r = 0.358, P = 0.001) and WBL ratio (P = 0.003). Difference in JLCA showed a stronger correlation than preoperative JLCA with differences in MA (P < 0.001) and WBL ratio (P < 0.001). Difference in JLCA was the only predictor of both difference in MA (P < 0.001) and difference in WBL ratio (P < 0.001). The difference between pre- and post-operative JLCA differed significantly between the under-correction, acceptable-correction, and over-correction groups (P = 0.033). Preoperative JLCA, however, did not differ significantly between the three groups. Neither preoperative JLCA nor difference in JLCA correlated with change in posterior slope. Preoperative degree of soft tissue laxity in the knee joint was related to the degree of alignment correction, but not to alignment correction error, in open-wedge HTO. Change in soft tissue laxity around the knee from before to after open-wedge HTO correlated with both correction amount and correction error. Therefore, a too large change in JLCA from before to after open-wedge osteotomy may be due to an overly large reduction in JLCA following osteotomy, suggesting alignment over

  16. Preliminary soft-tissue distraction versus checkrein ligament release after fasciectomy in the treatment of dupuytren proximal interphalangeal joint contractures.

    PubMed

    Craft, Randall O; Smith, Anthony A; Coakley, Brandon; Casey, William J; Rebecca, Alanna M; Duncan, Scott F M

    2011-11-01

    Checkrein ligament release for treatment of proximal interphalangeal joint Dupuytren contractures does not address the shortened arteries or deficient skin. The Digit Widget uses soft-tissue distraction to overcome these issues. This study compares checkrein ligament release after fasciectomy versus preliminary soft-tissue distraction, followed by operative release, for treatment of proximal interphalangeal joint Dupuytren contractures. The authors compared operative and postoperative characteristics of patients treated with either fasciectomy plus checkrein ligament release or Digit Widget distraction between 2001 and 2008. Seventeen patients (20 digits) underwent ligament release (mean contracture, 55.9 degrees); six of these 20 were reoperations. Thirteen patients (17 digits) underwent distraction (mean contracture, 67.6 degrees); 10 of 17 were reoperations. The 20 digits treated with fasciectomy plus ligament release had an average extension improvement of 31.4 degrees (range, -4 to 70 degrees). Digits treated with distraction had an average extension improvement of 53.4 degrees (range, 30 to 75 degrees) (p<0.001 versus ligament release). Three digits treated with distraction improved to full proximal interphalangeal extension. Initial contractures of 60 degrees or less treated by ligament release (n=12) or distraction (n=7) improved by means of 28.8 degrees and 47.7 degrees, respectively (p=0.048). Contractures greater than 60 degrees treated by ligament release (n=8) or distraction (n=10) improved by means of 35.3 degrees and 57.3 degrees, respectively (p=0.02). Soft-tissue distraction followed by operative release showed greater correction than Dupuytren fasciectomy plus checkrein ligament release. Therapeutic, III.

  17. Joint Source-Channel Decoding of Variable-Length Codes with Soft Information: A Survey

    NASA Astrophysics Data System (ADS)

    Guillemot, Christine; Siohan, Pierre

    2005-12-01

    Multimedia transmission over time-varying wireless channels presents a number of challenges beyond existing capabilities conceived so far for third-generation networks. Efficient quality-of-service (QoS) provisioning for multimedia on these channels may in particular require a loosening and a rethinking of the layer separation principle. In that context, joint source-channel decoding (JSCD) strategies have gained attention as viable alternatives to separate decoding of source and channel codes. A statistical framework based on hidden Markov models (HMM) capturing dependencies between the source and channel coding components sets the foundation for optimal design of techniques of joint decoding of source and channel codes. The problem has been largely addressed in the research community, by considering both fixed-length codes (FLC) and variable-length source codes (VLC) widely used in compression standards. Joint source-channel decoding of VLC raises specific difficulties due to the fact that the segmentation of the received bitstream into source symbols is random. This paper makes a survey of recent theoretical and practical advances in the area of JSCD with soft information of VLC-encoded sources. It first describes the main paths followed for designing efficient estimators for VLC-encoded sources, the key component of the JSCD iterative structure. It then presents the main issues involved in the application of the turbo principle to JSCD of VLC-encoded sources as well as the main approaches to source-controlled channel decoding. This survey terminates by performance illustrations with real image and video decoding systems.

  18. Smart LED allocation scheme for efficient multiuser visible light communication networks.

    PubMed

    Sewaiwar, Atul; Tiwari, Samrat Vikramaditya; Chung, Yeon Ho

    2015-05-18

    In a multiuser bidirectional visible light communication (VLC), a large number of LEDs or an LED array needs to be allocated in an efficient manner to ensure sustainable data rate and link quality. Moreover, in order to support an increasing or decreasing number of users in the network, the LED allocation is required to be performed dynamically. In this paper, a novel smart LED allocation scheme for efficient multiuser VLC networks is presented. The proposed scheme allocates RGB LEDs to multiple users in a dynamic and efficient fashion, while satisfying illumination requirements in an indoor environment. The smart LED array comprised of RGB LEDs is divided into sectors according to the location of the users. The allocated sectors then provide optical power concentration toward the users for efficient and reliable data transmission. An algorithm for the dynamic allocation of the LEDs is also presented. To verify its effective resource allocation feature of the proposed scheme, simulations were performed. It is found that the proposed smart LED allocation scheme provides the effect of optical beamforming toward individual users, thereby increasing the collective power concentration of the optical signals on the desirable users and resulting in significantly increased data rate, while ensuring sufficient illumination in a multiuser VLC environment.

  19. Tomlinson-Harashima Precoding for Multiuser MIMO Systems With Quantized CSI Feedback and User Scheduling

    NASA Astrophysics Data System (ADS)

    Sun, Liang; McKay, Matthew R.

    2014-08-01

    This paper studies the sum rate performance of a low complexity quantized CSI-based Tomlinson-Harashima (TH) precoding scheme for downlink multiuser MIMO tansmission, employing greedy user selection. The asymptotic distribution of the output signal to interference plus noise ratio of each selected user and the asymptotic sum rate as the number of users K grows large are derived by using extreme value theory. For fixed finite signal to noise ratios and a finite number of transmit antennas $n_T$, we prove that as K grows large, the proposed approach can achieve the optimal sum rate scaling of the MIMO broadcast channel. We also prove that, if we ignore the precoding loss, the average sum rate of this approach converges to the average sum capacity of the MIMO broadcast channel. Our results provide insights into the effect of multiuser interference caused by quantized CSI on the multiuser diversity gain.

  20. Genetic Local Search for Optimum Multiuser Detection Problem in DS-CDMA Systems

    NASA Astrophysics Data System (ADS)

    Wang, Shaowei; Ji, Xiaoyong

    Optimum multiuser detection (OMD) in direct-sequence code-division multiple access (DS-CDMA) systems is an NP-complete problem. In this paper, we present a genetic local search algorithm, which consists of an evolution strategy framework and a local improvement procedure. The evolution strategy searches the space of feasible, locally optimal solutions only. A fast iterated local search algorithm, which employs the proprietary characteristics of the OMD problem, produces local optima with great efficiency. Computer simulations show the bit error rate (BER) performance of the GLS outperforms other multiuser detectors in all cases discussed. The computation time is polynomial complexity in the number of users.

  1. Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation.

    PubMed

    Richard, Vincent; Cappozzo, Aurelio; Dumas, Raphaël

    2017-09-06

    Estimating joint kinematics from skin-marker trajectories recorded using stereophotogrammetry is complicated by soft tissue artefact (STA), an inexorable source of error. One solution is to use a bone pose estimator based on multi-body kinematics optimisation (MKO) embedding joint constraints to compensate for STA. However, there is some debate over the effectiveness of this method. The present study aimed to quantitatively assess the degree of agreement between reference (i.e., artefact-free) knee joint kinematics and the same kinematics estimated using MKO embedding six different knee joint models. The following motor tasks were assessed: level walking, hopping, cutting, running, sit-to-stand, and step-up. Reference knee kinematics was taken from pin-marker or biplane fluoroscopic data acquired concurrently with skin-marker data, made available by the respective authors. For each motor task, Bland-Altman analysis revealed that the performance of MKO varied according to the joint model used, with a wide discrepancy in results across degrees of freedom (DoFs), models and motor tasks (with a bias between -10.2° and 13.2° and between -10.2mm and 7.2mm, and with a confidence interval up to ±14.8° and ±11.1mm, for rotation and displacement, respectively). It can be concluded that, while MKO might occasionally improve kinematics estimation, as implemented to date it does not represent a reliable solution to the STA issue. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Postoperative Therapy for Chronic Thumb Carpometacarpal (CMC) Joint Dislocation.

    PubMed

    Wollstein, Ronit; Michael, Dafna; Harel, Hani

    2016-01-01

    Surgical arthroplasty of thumb carpometacarpal (CMC) joint osteoarthritis is commonly performed. Postoperative therapeutic protocols aim to improve range of motion and function of the revised thumb. We describe a case in which the thumb CMC joint had been chronically dislocated before surgery, with shortening of the soft-tissue dynamic and static stabilizers of the joint. The postoperative protocol addressed the soft tissues using splinting and exercises aimed at lengthening and strengthening these structures, with good results. It may be beneficial to evaluate soft-tissue tension and the pattern of thumb use after surgery for thumb CMC joint osteoarthritis to improve postoperative functional results. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  3. A Hybrid Multiuser Detector Based on MMSE and AFSA for TDRS System Forward Link

    PubMed Central

    Yin, Zhendong; Liu, Xiaohui

    2014-01-01

    This study mainly focuses on multiuser detection in tracking and data relay satellite (TDRS) system forward link. Minimum mean square error (MMSE) is a low complexity multiuser detection method, but MMSE detector cannot achieve satisfactory bit error ratio and near-far resistance, whereas artificial fish swarm algorithm (AFSA) is expert in optimization and it can realize the global convergence efficiently. Therefore, a hybrid multiuser detector based on MMSE and AFSA (MMSE-AFSA) is proposed in this paper. The result of MMSE and its modified formations are used as the initial values of artificial fishes to accelerate the speed of global convergence and reduce the iteration times for AFSA. The simulation results show that the bit error ratio and near-far resistance performances of the proposed detector are much better, compared with MF, DEC, and MMSE, and are quite close to OMD. Furthermore, the proposed MMSE-AFSA detector also has a large system capacity. PMID:24883418

  4. Introducing ORACLE: Library Processing in a Multi-User Environment.

    ERIC Educational Resources Information Center

    Queensland Library Board, Brisbane (Australia).

    Currently being developed by the State Library of Queensland, Australia, ORACLE (On-Line Retrieval of Acquisitions, Cataloguing, and Circulation Details for Library Enquiries) is a computerized library system designed to provide rapid processing of library materials in a multi-user environment. It is based on the Australian MARC format and fully…

  5. DEEP SPACE: High Resolution VR Platform for Multi-user Interactive Narratives

    NASA Astrophysics Data System (ADS)

    Kuka, Daniela; Elias, Oliver; Martins, Ronald; Lindinger, Christopher; Pramböck, Andreas; Jalsovec, Andreas; Maresch, Pascal; Hörtner, Horst; Brandl, Peter

    DEEP SPACE is a large-scale platform for interactive, stereoscopic and high resolution content. The spatial and the system design of DEEP SPACE are facing constraints of CAVETM-like systems in respect to multi-user interactive storytelling. To be used as research platform and as public exhibition space for many people, DEEP SPACE is capable to process interactive, stereoscopic applications on two projection walls with a size of 16 by 9 meters and a resolution of four times 1080p (4K) each. The processed applications are ranging from Virtual Reality (VR)-environments to 3D-movies to computationally intensive 2D-productions. In this paper, we are describing DEEP SPACE as an experimental VR platform for multi-user interactive storytelling. We are focusing on the system design relevant for the platform, including the integration of the Apple iPod Touch technology as VR control, and a special case study that is demonstrating the research efforts in the field of multi-user interactive storytelling. The described case study, entitled "Papyrate's Island", provides a prototypical scenario of how physical drawings may impact on digital narratives. In this special case, DEEP SPACE helps us to explore the hypothesis that drawing, a primordial human creative skill, gives us access to entirely new creative possibilities in the domain of interactive storytelling.

  6. A Soft Sensor-Based Three-Dimensional (3-D) Finger Motion Measurement System

    PubMed Central

    Park, Wookeun; Ro, Kyongkwan; Kim, Suin; Bae, Joonbum

    2017-01-01

    In this study, a soft sensor-based three-dimensional (3-D) finger motion measurement system is proposed. The sensors, made of the soft material Ecoflex, comprise embedded microchannels filled with a conductive liquid metal (EGaln). The superior elasticity, light weight, and sensitivity of soft sensors allows them to be embedded in environments in which conventional sensors cannot. Complicated finger joints, such as the carpometacarpal (CMC) joint of the thumb are modeled to specify the location of the sensors. Algorithms to decouple the signals from soft sensors are proposed to extract the pure flexion, extension, abduction, and adduction joint angles. The performance of the proposed system and algorithms are verified by comparison with a camera-based motion capture system. PMID:28241414

  7. To what extent is joint and muscle mechanics predicted by musculoskeletal models sensitive to soft tissue artefacts?

    PubMed

    Lamberto, Giuliano; Martelli, Saulo; Cappozzo, Aurelio; Mazzà, Claudia

    2017-09-06

    Musculoskeletal models are widely used to estimate joint kinematics, intersegmental loads, and muscle and joint contact forces during movement. These estimates can be heavily affected by the soft tissue artefact (STA) when input positional data are obtained using stereophotogrammetry, but this aspect has not yet been fully characterised for muscle and joint forces. This study aims to assess the sensitivity to the STA of three open-source musculoskeletal models, implemented in OpenSim. A baseline dataset of marker trajectories was created for each model from experimental data of one healthy volunteer. Five hundred STA realizations were then statistically generated using a marker-dependent model of the pelvis and lower limb artefact and added to the baseline data. The STA׳s impact on the musculoskeletal model estimates was finally quantified using a Monte Carlo analysis. The modelled STA distributions were in line with the literature. Observed output variations were comparable across the three models, and sensitivity to the STA was evident for most investigated quantities. Shape, magnitude and timing of the joint angle and moment time histories were not significantly affected throughout the entire gait cycle, whereas magnitude variations were observed for muscle and joint forces. Ranges of contact force variations differed between joints, with hip variations up to 1.8 times body weight observed. Variations of more than 30% were observed for some of the muscle forces. In conclusion, musculoskeletal simulations using stereophotogrammetry may be safely run when only interested in overall output patterns. Caution should be paid when more accurate estimated values are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Investigation on iterative multiuser detection physical layer network coding in two-way relay free-space optical links with turbulences and pointing errors.

    PubMed

    Abu-Almaalie, Zina; Ghassemlooy, Zabih; Bhatnagar, Manav R; Le-Minh, Hoa; Aslam, Nauman; Liaw, Shien-Kuei; Lee, It Ee

    2016-11-20

    Physical layer network coding (PNC) improves the throughput in wireless networks by enabling two nodes to exchange information using a minimum number of time slots. The PNC technique is proposed for two-way relay channel free space optical (TWR-FSO) communications with the aim of maximizing the utilization of network resources. The multipair TWR-FSO is considered in this paper, where a single antenna on each pair seeks to communicate via a common receiver aperture at the relay. Therefore, chip interleaving is adopted as a technique to separate the different transmitted signals at the relay node to perform PNC mapping. Accordingly, this scheme relies on the iterative multiuser technique for detection of users at the receiver. The bit error rate (BER) performance of the proposed system is examined under the combined influences of atmospheric loss, turbulence-induced channel fading, and pointing errors (PEs). By adopting the joint PNC mapping with interleaving and multiuser detection techniques, the BER results show that the proposed scheme can achieve a significant performance improvement against the degrading effects of turbulences and PEs. It is also demonstrated that a larger number of simultaneous users can be supported with this new scheme in establishing a communication link between multiple pairs of nodes in two time slots, thereby improving the channel capacity.

  9. Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA)

    NASA Image and Video Library

    2013-07-24

    ISS036-E-024569 (24 July 2013) --- European Space Agency astronaut Luca Parmitano, Expedition 36 flight engineer, works on the Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA) at a maintenance work station in the Harmony node of the International Space Station.

  10. Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA)

    NASA Image and Video Library

    2013-07-24

    ISS036-E-024605 (24 July 2013) --- European Space Agency astronaut Luca Parmitano, Expedition 36 flight engineer, works on the Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA) at a maintenance work station in the Harmony node of the International Space Station.

  11. Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA)

    NASA Image and Video Library

    2013-07-24

    ISS036-E-024637 (24 July 2013) --- European Space Agency astronaut Luca Parmitano, Expedition 36 flight engineer, works on the Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA) at a maintenance work station in the Harmony node of the International Space Station.

  12. A Modular Soft Robotic Wrist for Underwater Manipulation.

    PubMed

    Kurumaya, Shunichi; Phillips, Brennan T; Becker, Kaitlyn P; Rosen, Michelle H; Gruber, David F; Galloway, Kevin C; Suzumori, Koichi; Wood, Robert J

    2018-04-19

    This article presents the development of modular soft robotic wrist joint mechanisms for delicate and precise manipulation in the harsh deep-sea environment. The wrist consists of a rotary module and bending module, which can be combined with other actuators as part of a complete manipulator system. These mechanisms are part of a suite of soft robotic actuators being developed for deep-sea manipulation via submersibles and remotely operated vehicles, and are designed to be powered hydraulically with seawater. The wrist joint mechanisms can also be activated with pneumatic pressure for terrestrial-based applications, such as automated assembly and robotic locomotion. Here we report the development and characterization of a suite of rotary and bending modules by varying fiber number and silicone hardness. Performance of the complete soft robotic wrist is demonstrated in normal atmospheric conditions using both pneumatic and hydraulic pressures for actuation and under high ambient hydrostatic pressures equivalent to those found at least 2300 m deep in the ocean. This rugged modular wrist holds the potential to be utilized at full ocean depths (>10,000 m) and is a step forward in the development of jointed underwater soft robotic arms.

  13. Cabana Multi-User Spaceport Tour of KSC

    NASA Image and Video Library

    2017-02-17

    Kennedy Space Center Director Bob Cabana speaks to members of the news media on the balcony of Operations Support Building II describing the site's transition from a primarily government-only facility to a premier, multi-user spaceport. In the background is the Vehicle Assembly Building (VAB). Modifications were recently completed in the VAB where new work platforms were installed to support processing of NASA's Space Launch System rocket designed to send the Orion spacecraft on missions beyond low-Earth orbit.

  14. OpenGL in Multi-User Web-Based Applications

    NASA Astrophysics Data System (ADS)

    Szostek, K.; Piórkowski, A.

    In this article construction and potential of OpenGL multi-user web-based application are presented. The most common technologies like: .NET ASP, Java and Mono were used with specific OpenGL libraries to visualize tree-dimensional medical data. The most important conclusion of this work is that server side applications can easily take advantage of fast GPU and produce efficient results of advanced computation just like the visualization.

  15. The ATLAS multi-user upgrade and potential applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mustapha, B.; Nolen, J. A.; Savard, G.

    With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existingmore » ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~ 1 MeV/u and isotope production at ~ 6 MeV/u or at the full ATLAS energy of ~ 15 MeV/u. The concept and proposed implementation of the ATLAS multi-user upgrade will be presented. Future plans to enhance the flexibility of this upgrade will also be presented.« less

  16. The ATLAS multi-user upgrade and potential applications

    NASA Astrophysics Data System (ADS)

    Mustapha, B.; Nolen, J. A.; Savard, G.; Ostroumov, P. N.

    2017-12-01

    With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existing ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~1 MeV/u, isotope production and radiobiological studies at ~6 MeV/u and at the full ATLAS energy of ~15 MeV/u. The concept and proposed implementation of the ATLAS multi-user upgrade will be discussed. Future plans to enhance the flexibility of this upgrade will be presented.

  17. Cabana Multi-User Spaceport Tour of KSC

    NASA Image and Video Library

    2017-02-17

    Nancy Bray, director of Spaceport Integration and Services at NASA's Kennedy Space Center, speaks to members of the news media on the balcony of Operations Support Building II describing the site's transition from a primarily government-only facility to a premier, multi-user spaceport. In the background is the Vehicle Assembly Building (VAB). Modifications were recently completed in the VAB where new work platforms were installed to support processing of NASA's Space Launch System rocket designed to send the Orion spacecraft on missions beyond low-Earth orbit.

  18. Cabana Multi-User Spaceport Tour of KSC

    NASA Image and Video Library

    2017-02-17

    Tom Engler, director of Center Planning and Development at NASA's Kennedy Space Center, speaks to members of the news media on the balcony of Operations Support Building II describing the site's transition from a primarily government-only facility to a premier, multi-user spaceport. In the background is the Vehicle Assembly Building (VAB). Modifications were recently completed in the VAB where new work platforms were installed to support processing of NASA's Space Launch System rocket designed to send the Orion spacecraft on missions beyond low-Earth orbit.

  19. A Multiuser Detector Based on Artificial Bee Colony Algorithm for DS-UWB Systems

    PubMed Central

    Liu, Xiaohui

    2013-01-01

    Artificial Bee Colony (ABC) algorithm is an optimization algorithm based on the intelligent behavior of honey bee swarm. The ABC algorithm was developed to solve optimizing numerical problems and revealed premising results in processing time and solution quality. In ABC, a colony of artificial bees search for rich artificial food sources; the optimizing numerical problems are converted to the problem of finding the best parameter which minimizes an objective function. Then, the artificial bees randomly discover a population of initial solutions and then iteratively improve them by employing the behavior: moving towards better solutions by means of a neighbor search mechanism while abandoning poor solutions. In this paper, an efficient multiuser detector based on a suboptimal code mapping multiuser detector and artificial bee colony algorithm (SCM-ABC-MUD) is proposed and implemented in direct-sequence ultra-wideband (DS-UWB) systems under the additive white Gaussian noise (AWGN) channel. The simulation results demonstrate that the BER and the near-far effect resistance performances of this proposed algorithm are quite close to those of the optimum multiuser detector (OMD) while its computational complexity is much lower than that of OMD. Furthermore, the BER performance of SCM-ABC-MUD is not sensitive to the number of active users and can obtain a large system capacity. PMID:23983638

  20. Experimental demonstration of multiuser communication in deep water using time reversal.

    PubMed

    Shimura, T; Ochi, H; Song, H C

    2013-10-01

    Multiuser communication is demonstrated using experimental data (450-550 Hz) collected in deep water, south of Japan. The multiple users are spatially distributed either in depth or range while a 114-m long, 20-element vertical array (i.e., base station) is deployed to around the sound channel axis (~1000 m). First, signals received separately from ranges of 150 km and 180 km at various depths are combined asynchronously to generate multiuser communication sequences for subsequent processing, achieving an aggregate data rate of 300 bits/s for up to three users. Adaptive time reversal is employed to separate collided packets at the base station, followed by a single channel decision feedback equalizer. Then it is demonstrated that two users separated by 3 km in range at ~1000 m depth can transmit information simultaneously to the base station at ~500 km range with an aggregate data rate of 200 bits/s.

  1. Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jianchao; Ding, Yonghua, E-mail: yhding@mail.hust.edu.cn; Zhang, Xiaoqing

    2014-11-15

    A new soft X-ray diagnostic system has been designed on the Joint Texas Experimental Tokamak (J-TEXT) aiming to observe and survey the magnetohydrodynamic (MHD) activities. The system consists of five cameras located at the same toroidal position. Each camera has 16 photodiode elements. Three imaging cameras view the internal plasma region (r/a < 0.7) with a spatial resolution about 2 cm. By tomographic method, heat transport outside from the 1/1 mode X-point during the sawtooth collapse is found. The other two cameras with a higher spatial resolution 1 cm are designed for monitoring local MHD activities respectively in plasma coremore » and boundary.« less

  2. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty

    PubMed Central

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-01-01

    Abstract Background: This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Methods: Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. Results: The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (−0.09 mm, 95% confidence interval [CI]: −0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: −1.01 to −0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. Conclusion: The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal

  3. Color coded multiple access scheme for bidirectional multiuser visible light communications in smart home technologies

    NASA Astrophysics Data System (ADS)

    Tiwari, Samrat Vikramaditya; Sewaiwar, Atul; Chung, Yeon-Ho

    2015-10-01

    In optical wireless communications, multiple channel transmission is an attractive solution to enhancing capacity and system performance. A new modulation scheme called color coded multiple access (CCMA) for bidirectional multiuser visible light communications (VLC) is presented for smart home applications. The proposed scheme uses red, green and blue (RGB) light emitting diodes (LED) for downlink and phosphor based white LED (P-LED) for uplink to establish a bidirectional VLC and also employs orthogonal codes to support multiple users and devices. The downlink transmission for data user devices and smart home devices is provided using red and green colors from the RGB LEDs, respectively, while uplink transmission from both types of devices is performed using the blue color from P-LEDs. Simulations are conducted to verify the performance of the proposed scheme. It is found that the proposed bidirectional multiuser scheme is efficient in terms of data rate and performance. In addition, since the proposed scheme uses RGB signals for downlink data transmission, it provides flicker-free illumination that would lend itself to multiuser VLC system for smart home applications.

  4. The Lateral Proximal Phalanx Flap for Contractures and Soft Tissue Defects in the Proximal Interphalangeal Joint: An Anatomical and Clinical Study.

    PubMed

    Beltrán, Aldo G; Romero, Camilo J

    2017-01-01

    Background: The management of contractures and soft tissue defects in the proximal interphalangeal (PIP) finger joint remains a challenge. We report a transposition flap from the lateral skin of the proximal phalanx that is based on perforating branches of the digital arteries and can be used safely for both palmar and dorsal cover defects. Methods: We first completed an anatomic study, dissecting 20 fingers in fresh cadavers with arterial injections and made the new flap in patients with dorsal or palmar defects in PIP joints. Results: In cadavers, we can reveal 4 constant branches from each digital artery in the proximal phalanx, with the more distal just in the PIP joint constituting the flap pedicle. Between February 2010 and February 2015, we designed 33 flaps in 29 patients, 7 for dorsal and 26 for palmar defects, with no instances of flap necrosis and 4 distal epidermolysis. The patients were between 4 and 69 years with no major complications, and all of the skin defects in the PIP joint were resolved satisfactorily without any relevant sequelae at the donor site. Conclusions: This flap procedure is an easy, reliable, versatile, and safe technique, and could be an important tool for the management of difficult skin defects and contractures at the PIP joint level.

  5. Soft tissue artifact compensation in knee kinematics by multi-body optimization: Performance of subject-specific knee joint models.

    PubMed

    Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A

    2015-11-05

    Soft tissue artifact (STA) distort marker-based knee kinematics measures and make them difficult to use in clinical practice. None of the current methods designed to compensate for STA is suitable, but multi-body optimization (MBO) has demonstrated encouraging results and can be improved. The goal of this study was to develop and validate the performance of knee joint models, with anatomical and subject-specific kinematic constraints, used in MBO to reduce STA errors. Twenty subjects were recruited: 10 healthy and 10 osteoarthritis (OA) subjects. Subject-specific knee joint models were evaluated by comparing dynamic knee kinematics recorded by a motion capture system (KneeKG™) and optimized with MBO to quasi-static knee kinematics measured by a low-dose, upright, biplanar radiographic imaging system (EOS(®)). Errors due to STA ranged from 1.6° to 22.4° for knee rotations and from 0.8 mm to 14.9 mm for knee displacements in healthy and OA subjects. Subject-specific knee joint models were most effective in compensating for STA in terms of abduction-adduction, inter-external rotation and antero-posterior displacement. Root mean square errors with subject-specific knee joint models ranged from 2.2±1.2° to 6.0±3.9° for knee rotations and from 2.4±1.1 mm to 4.3±2.4 mm for knee displacements in healthy and OA subjects, respectively. Our study shows that MBO can be improved with subject-specific knee joint models, and that the quality of the motion capture calibration is critical. Future investigations should focus on more refined knee joint models to reproduce specific OA knee geometry and physiology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. First Eigenmode Transmission by High Efficient CSI Estimation for Multiuser Massive MIMO Using Millimeter Wave Bands.

    PubMed

    Maruta, Kazuki; Iwakuni, Tatsuhiko; Ohta, Atsushi; Arai, Takuto; Shirato, Yushi; Kurosaki, Satoshi; Iizuka, Masataka

    2016-07-08

    Drastic improvements in transmission rate and system capacity are required towards 5th generation mobile communications (5G). One promising approach, utilizing the millimeter wave band for its rich spectrum resources, suffers area coverage shortfalls due to its large propagation loss. Fortunately, massive multiple-input multiple-output (MIMO) can offset this shortfall as well as offer high order spatial multiplexing gain. Multiuser MIMO is also effective in further enhancing system capacity by multiplexing spatially de-correlated users. However, the transmission performance of multiuser MIMO is strongly degraded by channel time variation, which causes inter-user interference since null steering must be performed at the transmitter. This paper first addresses the effectiveness of multiuser massive MIMO transmission that exploits the first eigenmode for each user. In Line-of-Sight (LoS) dominant channel environments, the first eigenmode is chiefly formed by the LoS component, which is highly correlated with user movement. Therefore, the first eigenmode provided by a large antenna array can improve the robustness against the channel time variation. In addition, we propose a simplified beamforming scheme based on high efficient channel state information (CSI) estimation that extracts the LoS component. We also show that this approximate beamforming can achieve throughput performance comparable to that of the rigorous first eigenmode transmission. Our proposed multiuser massive MIMO scheme can open the door for practical millimeter wave communication with enhanced system capacity.

  7. Robust THP Transceiver Designs for Multiuser MIMO Downlink with Imperfect CSIT

    NASA Astrophysics Data System (ADS)

    Ubaidulla, P.; Chockalingam, A.

    2009-12-01

    We present robust joint nonlinear transceiver designs for multiuser multiple-input multiple-output (MIMO) downlink in the presence of imperfections in the channel state information at the transmitter (CSIT). The base station (BS) is equipped with multiple transmit antennas, and each user terminal is equipped with one or more receive antennas. The BS employs Tomlinson-Harashima precoding (THP) for interuser interference precancellation at the transmitter. We consider robust transceiver designs that jointly optimize the transmit THP filters and receive filter for two models of CSIT errors. The first model is a stochastic error (SE) model, where the CSIT error is Gaussian-distributed. This model is applicable when the CSIT error is dominated by channel estimation error. In this case, the proposed robust transceiver design seeks to minimize a stochastic function of the sum mean square error (SMSE) under a constraint on the total BS transmit power. We propose an iterative algorithm to solve this problem. The other model we consider is a norm-bounded error (NBE) model, where the CSIT error can be specified by an uncertainty set. This model is applicable when the CSIT error is dominated by quantization errors. In this case, we consider a worst-case design. For this model, we consider robust (i) minimum SMSE, (ii) MSE-constrained, and (iii) MSE-balancing transceiver designs. We propose iterative algorithms to solve these problems, wherein each iteration involves a pair of semidefinite programs (SDPs). Further, we consider an extension of the proposed algorithm to the case with per-antenna power constraints. We evaluate the robustness of the proposed algorithms to imperfections in CSIT through simulation, and show that the proposed robust designs outperform nonrobust designs as well as robust linear transceiver designs reported in the recent literature.

  8. Interfacing laboratory instruments to multiuser, virtual memory computers

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R.; Stang, David B.; Roth, Don J.

    1989-01-01

    Incentives, problems and solutions associated with interfacing laboratory equipment with multiuser, virtual memory computers are presented. The major difficulty concerns how to utilize these computers effectively in a medium sized research group. This entails optimization of hardware interconnections and software to facilitate multiple instrument control, data acquisition and processing. The architecture of the system that was devised, and associated programming and subroutines are described. An example program involving computer controlled hardware for ultrasonic scan imaging is provided to illustrate the operational features.

  9. Center Planning and Development: Multi-User Spaceport Initiatives

    NASA Technical Reports Server (NTRS)

    Kennedy, Christopher John

    2015-01-01

    The Vehicle Assembly building at NASAs Kennedy Space Center has been used since 1966 to vertically assemble every launch vehicle, since the Apollo Program, launched from Launch Complex 39 (LC-39). After the cancellation of the Constellation Program in 2010 and the retirement of the Space Shuttle Program in 2011, the VAB faced an uncertain future. As the Space Launch System (SLS) gained a foothold as the future of American spaceflight to deep space, NASA was only using a portion of the VABs initial potential. With three high bays connected to the Crawler Way transportation system, the potential exists for up to three rockets to be simultaneously processed for launch. The Kennedy Space Center (KSC) Master plan, supported by the Center Planning and Development (CPD) Directorate, is guiding Kennedy toward a 21st century multi-user spaceport. This concept will maintain Kennedy as the United States premier gateway to space and provide multi-user operations through partnerships with the commercial aerospace industry. Commercial aerospace companies, now tasked with transporting cargo and, in the future, astronauts to the International Space Station (ISS) via the Commercial Resupply Service (CRS) and Commercial Crew Program (CCP), are a rapidly growing industry with increasing capabilities to make launch operations more economical for both private companies and the government. Commercial operations to Low Earth Orbit allow the government to focus on travel to farther destinations through the SLS Program. With LC-39B designated as a multi-use launch pad, companies seeking to use it will require an integration facility to assemble, integrate, and test their launch vehicle. An Announcement for Proposals (AFP) was released in June, beginning the process of finding a non-NASA user for High Bay 2 (HB2) and the Mobile Launcher Platforms (MLPs). An Industry Day, a business meeting and tour for interested companies and organizations, was also arranged to identify and answer any

  10. Studying the Effectiveness of Multi-User Immersive Environments for Collaborative Evaluation Tasks

    ERIC Educational Resources Information Center

    Lorenzo, Carlos-Miguel; Sicilia, Miguel Angel; Sanchez, Salvador

    2012-01-01

    Massively Multiuser On-line Learning (MMOL) Platforms, often called "virtual learning worlds", constitute a still unexplored context for communication-enhanced learning, where synchronous communication skills in an explicit social setting enhance the potential of effective collaboration. In this paper, we report on an experimental study of…

  11. Performance Analysis of Physical Layer Security of Opportunistic Scheduling in Multiuser Multirelay Cooperative Networks

    PubMed Central

    Shim, Kyusung; Do, Nhu Tri; An, Beongku

    2017-01-01

    In this paper, we study the physical layer security (PLS) of opportunistic scheduling for uplink scenarios of multiuser multirelay cooperative networks. To this end, we propose a low-complexity, yet comparable secrecy performance source relay selection scheme, called the proposed source relay selection (PSRS) scheme. Specifically, the PSRS scheme first selects the least vulnerable source and then selects the relay that maximizes the system secrecy capacity for the given selected source. Additionally, the maximal ratio combining (MRC) technique and the selection combining (SC) technique are considered at the eavesdropper, respectively. Investigating the system performance in terms of secrecy outage probability (SOP), closed-form expressions of the SOP are derived. The developed analysis is corroborated through Monte Carlo simulation. Numerical results show that the PSRS scheme significantly improves the secure ability of the system compared to that of the random source relay selection scheme, but does not outperform the optimal joint source relay selection (OJSRS) scheme. However, the PSRS scheme drastically reduces the required amount of channel state information (CSI) estimations compared to that required by the OJSRS scheme, specially in dense cooperative networks. PMID:28212286

  12. Design, fabrication and control of soft robots.

    PubMed

    Rus, Daniela; Tolley, Michael T

    2015-05-28

    Conventionally, engineers have employed rigid materials to fabricate precise, predictable robotic systems, which are easily modelled as rigid members connected at discrete joints. Natural systems, however, often match or exceed the performance of robotic systems with deformable bodies. Cephalopods, for example, achieve amazing feats of manipulation and locomotion without a skeleton; even vertebrates such as humans achieve dynamic gaits by storing elastic energy in their compliant bones and soft tissues. Inspired by nature, engineers have begun to explore the design and control of soft-bodied robots composed of compliant materials. This Review discusses recent developments in the emerging field of soft robotics.

  13. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis.

    PubMed

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-09-01

    This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (-0.09 mm, 95% confidence interval [CI]: -0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: -1.01 to -0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal (around 1 mm or 1°) and therefore may have little effect on

  14. Addressing multi-use issues in sustainable forest management with signal-transfer modeling

    Treesearch

    Robert J. Luxmoore; William W. Hargrove; M. Lynn Tharp; W. Mac Post; Michael W. Berry; Karen S. Minser; Wendell P. Cropper; Dale W. Johnson; Boris Zeide; Ralph L. Amateis; Harold E. Burkhart; V. Clark Baldwin; Kelly D. Peterson

    2002-01-01

    Management decisions concerning impacts of projected changes in environmental and social conditions on multi-use forest products and services, such as productivity, water supply or carbon sequestration, may be facilitated with signal-transfer modeling. This simulation method utilizes a hierarchy of simulators in which the integrated responses (signals) from smaller-...

  15. Preservice Teachers Experience Reading Response Pedagogy in a Multi-User Virtual Environment

    ERIC Educational Resources Information Center

    Dooley, Caitlin McMunn; Calandra, Brendan; Harmon, Stephen

    2014-01-01

    This qualitative case study describes how 18 preservice teachers learned to nurture literary meaning-making via activities based on Louise Rosenblatt's Reader Response Theory within a multi-user virtual environment (MUVE). Participants re-created and responded to scenes from selected works of children's literature in Second Life as a way to…

  16. Multiuser TOA Estimation Algorithm in DS-CDMA Sparse Channel for Radiolocation

    NASA Astrophysics Data System (ADS)

    Kim, Sunwoo

    This letter considers multiuser time delay estimation in a sparse channel environment for radiolocation. The generalized successive interference cancellation (GSIC) algorithm is used to eliminate the multiple access interference (MAI). To adapt GSIC to sparse channels the alternating maximization (AM) algorithm is considered, and the continuous time delay of each path is estimated without requiring a priori known data sequences.

  17. Theoretical Limits on Multiuser Molecular Communication in Internet of Nano-Bio Things.

    PubMed

    Dinc, Ergin; Akan, Ozgur B

    2017-06-01

    In nano-bio networks, multiple transmitter-receiver pairs will operate in the same medium. Both inter-symbol interference and multi-user interference can cause saturation at the receiver side, and this effect may cause an outage. Thus, we propose a tractable framework to calculate the theoretical operating points for fully absorbing receiver.

  18. An FPGA-based DS-CDMA multiuser demodulator employing adaptive multistage parallel interference cancellation

    NASA Astrophysics Data System (ADS)

    Li, Xinhua; Song, Zhenyu; Zhan, Yongjie; Wu, Qiongzhi

    2009-12-01

    Since the system capacity is severely limited, reducing the multiple access interfere (MAI) is necessary in the multiuser direct-sequence code division multiple access (DS-CDMA) system which is used in the telecommunication terminals data-transferred link system. In this paper, we adopt an adaptive multistage parallel interference cancellation structure in the demodulator based on the least mean square (LMS) algorithm to eliminate the MAI on the basis of overviewing various of multiuser dectection schemes. Neither a training sequence nor a pilot signal is needed in the proposed scheme, and its implementation complexity can be greatly reduced by a LMS approximate algorithm. The algorithm and its FPGA implementation is then derived. Simulation results of the proposed adaptive PIC can outperform some of the existing interference cancellation methods in AWGN channels. The hardware setup of mutiuser demodulator is described, and the experimental results based on it demonstrate that the simulation results shows large performance gains over the conventional single-user demodulator.

  19. Smart Braid Feedback for the Closed-Loop Control of Soft Robotic Systems.

    PubMed

    Felt, Wyatt; Chin, Khai Yi; Remy, C David

    2017-09-01

    This article experimentally investigates the potential of using flexible, inductance-based contraction sensors in the closed-loop motion control of soft robots. Accurate motion control remains a highly challenging task for soft robotic systems. Precise models of the actuation dynamics and environmental interactions are often unavailable. This renders open-loop control impossible, while closed-loop control suffers from a lack of suitable feedback. Conventional motion sensors, such as linear or rotary encoders, are difficult to adapt to robots that lack discrete mechanical joints. The rigid nature of these sensors runs contrary to the aspirational benefits of soft systems. As truly soft sensor solutions are still in their infancy, motion control of soft robots has so far relied on laboratory-based sensing systems such as motion capture, electromagnetic (EM) tracking, or Fiber Bragg Gratings. In this article, we used embedded flexible sensors known as Smart Braids to sense the contraction of McKibben muscles through changes in inductance. We evaluated closed-loop control on two systems: a revolute joint and a planar, one degree of freedom continuum manipulator. In the revolute joint, our proposed controller compensated for elasticity in the actuator connections. The Smart Braid feedback allowed motion control with a steady-state root-mean-square (RMS) error of [1.5]°. In the continuum manipulator, Smart Braid feedback enabled tracking of the desired tip angle with a steady-state RMS error of [1.25]°. This work demonstrates that Smart Braid sensors can provide accurate position feedback in closed-loop motion control suitable for field applications of soft robotic systems.

  20. A Robotic Coach Architecture for Elder Care (ROCARE) Based on Multi-User Engagement Models.

    PubMed

    Fan, Jing; Bian, Dayi; Zheng, Zhi; Beuscher, Linda; Newhouse, Paul A; Mion, Lorraine C; Sarkar, Nilanjan

    2017-08-01

    The aging population with its concomitant medical conditions, physical and cognitive impairments, at a time of strained resources, establishes the urgent need to explore advanced technologies that may enhance function and quality of life. Recently, robotic technology, especially socially assistive robotics has been investigated to address the physical, cognitive, and social needs of older adults. Most system to date have predominantly focused on one-on-one human robot interaction (HRI). In this paper, we present a multi-user engagement-based robotic coach system architecture (ROCARE). ROCARE is capable of administering both one-on-one and multi-user HRI, providing implicit and explicit channels of communication, and individualized activity management for long-term engagement. Two preliminary feasibility studies, a one-on-one interaction and a triadic interaction with two humans and a robot, were conducted and the results indicated potential usefulness and acceptance by older adults, with and without cognitive impairment.

  1. Next Generation Tissue Engineering of Orthopedic Soft Tissue-to-Bone Interfaces.

    PubMed

    Boys, Alexander J; McCorry, Mary Clare; Rodeo, Scott; Bonassar, Lawrence J; Estroff, Lara A

    2017-09-01

    Soft tissue-to-bone interfaces are complex structures that consist of gradients of extracellular matrix materials, cell phenotypes, and biochemical signals. These interfaces, called entheses for ligaments, tendons, and the meniscus, are crucial to joint function, transferring mechanical loads and stabilizing orthopedic joints. When injuries occur to connected soft tissue, the enthesis must be re-established to restore function, but due to structural complexity, repair has proven challenging. Tissue engineering offers a promising solution for regenerating these tissues. This prospective review discusses methodologies for tissue engineering the enthesis, outlined in three key design inputs: materials processing methods, cellular contributions, and biochemical factors.

  2. Memorandum : feasibility assessment, bicycle or bicycle/pedestrian (multi-user) facility at Appomattox Court house NHP

    DOT National Transportation Integrated Search

    2007-10-12

    This memorandum provides a preliminary feasibility assessment for a bicycle or combined bicycle/pedestrian (i.e., multi-user) facility at Appomattox Court House National Historical Park (NHP). This assessment is based on discussions with park staff, ...

  3. Civic Participation among Seventh-Grade Social Studies Students in Multi-User Virtual Environments

    ERIC Educational Resources Information Center

    Zieger, Laura; Farber, Matthew

    2012-01-01

    Technological advances on the Internet now enable students to develop participation skills in virtual worlds. Similar to controlling a character in a video game, multi-user virtual environments, or MUVEs, allow participants to interact with others in synchronous, online settings. The authors of this study created a link between MUVEs and…

  4. Tunable optical frequency comb enabled scalable and cost-effective multiuser orthogonal frequency-division multiple access passive optical network with source-free optical network units.

    PubMed

    Chen, Chen; Zhang, Chongfu; Liu, Deming; Qiu, Kun; Liu, Shuang

    2012-10-01

    We propose and experimentally demonstrate a multiuser orthogonal frequency-division multiple access passive optical network (OFDMA-PON) with source-free optical network units (ONUs), enabled by tunable optical frequency comb generation technology. By cascading a phase modulator (PM) and an intensity modulator and dynamically controlling the peak-to-peak voltage of a PM driven signal, a tunable optical frequency comb source can be generated. It is utilized to assist the configuration of a multiple source-free ONUs enhanced OFDMA-PON where simultaneous and interference-free multiuser upstream transmission over a single wavelength can be efficiently supported. The proposed multiuser OFDMA-PON is scalable and cost effective, and its feasibility is successfully verified by experiment.

  5. Inspiring Equal Contribution and Opportunity in a 3D Multi-User Virtual Environment: Bringing Together Men Gamers and Women Non-Gamers in Second Life[R

    ERIC Educational Resources Information Center

    deNoyelles, Aimee; Seo, Kay Kyeong-Ju

    2012-01-01

    A 3D multi-user virtual environment holds promise to support and enhance student online learning communities due to its ability to promote global synchronous interaction and collaboration, rich multisensory experience and expression, and elaborate design capabilities. Second Life[R], a multi-user virtual environment intended for adult users 18 and…

  6. Soft Tissue Deformations Contribute to the Mechanics of Walking in Obese Adults

    PubMed Central

    Fu, Xiao-Yu; Zelik, Karl E.; Board, Wayne J.; Browning, Raymond C.; Kuo, Arthur D.

    2014-01-01

    Obesity not only adds to the mass that must be carried during walking, but also changes body composition. Although extra mass causes roughly proportional increases in musculoskeletal loading, less well understood is the effect of relatively soft and mechanically compliant adipose tissue. Purpose To estimate the work performed by soft tissue deformations during walking. The soft tissue would be expected to experience damped oscillations, particularly from high force transients following heel strike, and could potentially change the mechanical work demands for walking. Method We analyzed treadmill walking data at 1.25 m/s for 11 obese (BMI > 30 kg/m2) and 9 non-obese (BMI < 30 kg/m2) adults. The soft tissue work was quantified with a method that compares the work performed by lower extremity joints as derived using assumptions of rigid body segments, with that estimated without rigid body assumptions. Results Relative to body mass, obese and non-obese individuals perform similar amounts of mechanical work. But negative work performed by soft tissues was significantly greater in obese individuals (p= 0.0102), equivalent to about 0.36 J/kg vs. 0.27 J/kg in non-obese individuals. The negative (dissipative) work by soft tissues occurred mainly after heel strike, and for obese individuals was comparable in magnitude to the total negative work from all of the joints combined (0.34 J/kg vs. 0.33 J/kg for obese and non-obese adults, respectively). Although the joints performed a relatively similar amount of work overall, obese individuals performed less negative work actively at the knee. Conclusion The greater proportion of soft tissues in obese individuals results in substantial changes in the amount, location, and timing of work, and may also impact metabolic energy expenditure during walking. PMID:25380475

  7. Managing Cognitive Load in Educational Multi-User Virtual Environments: Reflection on Design Practice

    ERIC Educational Resources Information Center

    Nelson, Brian C.; Erlandson, Benjamin E.

    2008-01-01

    In this paper, we explore how the application of multimedia design principles may inform the development of educational multi-user virtual environments (MUVEs). We look at design principles that have been shown to help learners manage cognitive load within multimedia environments and conduct a conjectural analysis of the extent to which such…

  8. Influence of Four Different Abutment Materials and the Adhesive Joint of Two-Piece Abutments on Cervical Implant Bone and Soft Tissue.

    PubMed

    Mehl, Christian; Gassling, Volker; Schultz-Langerhans, Stephan; Açil, Yahya; Bähr, Telse; Wiltfang, Jörg; Kern, Matthias

    The main aim of this study was to evaluate the influence of four different abutment materials and the adhesive joint of two-piece abutments on the cervical implant bone and soft tissue. Sixty-four titanium implants (Camlog Conelog; 4.3 ± 9 mm) were placed bone level into the edentulous arches of four minipigs. Four different types of abutments were placed at implant exposure: zirconium dioxide, lithium disilicate, and titanium bonded to a titanium luting base with resin cement; one-piece titanium abutments served as the control. The animals were sacrificed 6 months after implant exposure, and the bone-to-implant contact (BIC) area, sulcus depth, the length of the junctional epithelium and the connective tissue, the biologic width, and first cervical BIC-implant shoulder distance were measured using histomorphometry and light and fluorescence microscopy. Overall, 14 implants were lost (22%). At exposure, the implant shoulder-bone distance was 0.6 ± 0.7 mm. Six months later, the bone loss was 2.1 ± 1.2 mm measured histomorphometrically. There was a significant difference between the two measurements (P ≤ .0001). No significant influence could be found between any of the abutment materials with regard to bone loss or soft tissue anatomy (P > .05), with the exception of zirconium dioxide and onepiece titanium abutments when measuring the length of the junctional epithelium (P ≤ .01). The maxilla provided significantly more soft tissue and less bone loss compared with the mandible (P ≤ .02). All tested abutment materials and techniques seem to be comparable with regard to soft tissue properties and the cervical bone level.

  9. Large Osteoarthritic Cyst Presenting as Soft Tissue Tumour – A Case Report

    PubMed Central

    Kosuge, DD; Park, DH; Cannon, SR; Briggs, TW; Pollock, RC; Skinner, JA

    2007-01-01

    Large osteoarthritic cysts can sometimes be difficult to distinguish from primary osseous and soft tissue tumours. We present such a case involving a cyst arising from the hip joint and eroding the acetabulum which presented as a soft tissue malignancy referred to a tertiary bone and soft tissue tumour centre. We discuss the diagnostic problems it may pose, and present a literature review of the subject. PMID:17535605

  10. Soft tissue knee contracture of the knee due to melorheostosis, treated by total knee arthroplasty.

    PubMed

    Moulder, Elizabeth; Marsh, Clayton

    2006-10-01

    Melorheostosis is a rare condition which can cause soft tissue joint contractures. We present a case of melorheostosis causing disabling knee joint contracture, treated successfully by total knee arthroplasty.

  11. Stakeholders Opinions on Multi-Use Deep Water Offshore Platform in Hsiao-Liu-Chiu, Taiwan

    PubMed Central

    Sie, Ya-Tsune; Chang, Yang-Chi; Lu, Shiau-Yun

    2018-01-01

    This paper describes a group model building activity designed to elicit the potential effects a projected multi-use deep water offshore platform may have on its local environment, including ecological and socio-economic issues. As such a platform is proposed for construction around the island of Hsiao-Liu-Chiu, Taiwan, we organized several meetings with the local stakeholders and structured the debates using group modeling methods to promote consensus. During the process, the participants iteratively built and revised a causal-loop diagram that summarizes their opinions. Overall, local stakeholders concluded that a multi-use deep water offshore marine platform might have beneficial effects for Hsiao-Liu-Chiu because more tourists and fish could be attracted by the structure, but they also raised some potential problems regarding the law in Taiwan and the design of the offshore platform, especially its resistance to extreme weather. We report the method used and the main results and insights gained during the process. PMID:29415521

  12. A Robotic Coach Architecture for Elder Care (ROCARE) Based on Multi-user Engagement Models

    PubMed Central

    Fan, Jing; Bian, Dayi; Zheng, Zhi; Beuscher, Linda; Newhouse, Paul A.; Mion, Lorraine C.; Sarkar, Nilanjan

    2017-01-01

    The aging population with its concomitant medical conditions, physical and cognitive impairments, at a time of strained resources, establishes the urgent need to explore advanced technologies that may enhance function and quality of life. Recently, robotic technology, especially socially assistive robotics has been investigated to address the physical, cognitive, and social needs of older adults. Most system to date have predominantly focused on one-on-one human robot interaction (HRI). In this paper, we present a multi-user engagement-based robotic coach system architecture (ROCARE). ROCARE is capable of administering both one-on-one and multi-user HRI, providing implicit and explicit channels of communication, and individualized activity management for long-term engagement. Two preliminary feasibility studies, a one-on-one interaction and a triadic interaction with two humans and a robot, were conducted and the results indicated potential usefulness and acceptance by older adults, with and without cognitive impairment. PMID:28113672

  13. Multiuser Droplet Combustion Apparatus Developed to Conduct Combustion Experiments

    NASA Technical Reports Server (NTRS)

    Myhre, Craig A.

    2001-01-01

    A major portion of the energy produced in the world today comes from the combustion or burning of liquid hydrocarbon fuels in the form of droplets. However, despite vigorous scientific examinations for over a century, researchers still lack a full understanding of many fundamental combustion processes of liquid fuels. Understanding how these fuel droplets ignite, spread, and extinguish themselves will help us develop more efficient ways of energy production and propulsion, as well as help us deal better with the problems of combustion-generated pollution and fire hazards associated with liquid combustibles. The ability to conduct more controlled experiments in space, without the complication of gravity, provides scientists with an opportunity to examine these complicated processes closely. The Multiuser Droplet Combustion Apparatus (MDCA) supports this continued research under microgravity conditions. The objectives are to improve understanding of fundamental droplet phenomena affected by gravity, to use research results to advance droplet combustion science and technology on Earth, and to address issues of fire hazards associated with liquid combustibles on Earth and in space. MDCA is a multiuser facility designed to accommodate different combustion science experiments. The modular approach permits the on-orbit replacement of droplet combustion principal investigator experiments such as different fuels, droplet-dispensing needles, and droplet-tethering mechanisms. Large components such as the avionics, diagnostics, and base-plate remain on the International Space Station to reduce the launch mass of new experiments. MDCA is also designed to operate in concert with ground systems on Earth to minimize the involvement of the crew during orbit.

  14. A Multiuser Manufacturing Resource Service Composition Method Based on the Bees Algorithm

    PubMed Central

    Xie, Yongquan; Zhou, Zude; Pham, Duc Truong; Xu, Wenjun; Ji, Chunqian

    2015-01-01

    In order to realize an optimal resource service allocation in current open and service-oriented manufacturing model, multiuser resource service composition (RSC) is modeled as a combinational and constrained multiobjective problem. The model takes into account both subjective and objective quality of service (QoS) properties as representatives to evaluate a solution. The QoS properties aggregation and evaluation techniques are based on existing researches. The basic Bees Algorithm is tailored for finding a near optimal solution to the model, since the basic version is only proposed to find a desired solution in continuous domain and thus not suitable for solving the problem modeled in our study. Particular rules are designed for handling the constraints and finding Pareto optimality. In addition, the established model introduces a trusted service set to each user so that the algorithm could start by searching in the neighbor of more reliable service chains (known as seeds) than those randomly generated. The advantages of these techniques are validated by experiments in terms of success rate, searching speed, ability of avoiding ingenuity, and so forth. The results demonstrate the effectiveness of the proposed method in handling multiuser RSC problems. PMID:26339232

  15. Soft tissues store and return mechanical energy in human running.

    PubMed

    Riddick, R C; Kuo, A D

    2016-02-08

    During human running, softer parts of the body may deform under load and dissipate mechanical energy. Although tissues such as the heel pad have been characterized individually, the aggregate work performed by all soft tissues during running is unknown. We therefore estimated the work performed by soft tissues (N=8 healthy adults) at running speeds ranging 2-5 m s(-1), computed as the difference between joint work performed on rigid segments, and whole-body estimates of work performed on the (non-rigid) body center of mass (COM) and peripheral to the COM. Soft tissues performed aggregate negative work, with magnitude increasing linearly with speed. The amount was about -19 J per stance phase at a nominal 3 m s(-1), accounting for more than 25% of stance phase negative work performed by the entire body. Fluctuations in soft tissue mechanical power over time resembled a damped oscillation starting at ground contact, with peak negative power comparable to that for the knee joint (about -500 W). Even the positive work from soft tissue rebound was significant, about 13 J per stance phase (about 17% of the positive work of the entire body). Assuming that the net dissipative work is offset by an equal amount of active, positive muscle work performed at 25% efficiency, soft tissue dissipation could account for about 29% of the net metabolic expenditure for running at 5 m s(-1). During running, soft tissue deformations dissipate mechanical energy that must be offset by active muscle work at non-negligible metabolic cost. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Next Generation Tissue Engineering of Orthopedic Soft Tissue-to-Bone Interfaces

    PubMed Central

    Boys, Alexander J.; McCorry, Mary Clare; Rodeo, Scott; Bonassar, Lawrence J.; Estroff, Lara A.

    2017-01-01

    Soft tissue-to-bone interfaces are complex structures that consist of gradients of extracellular matrix materials, cell phenotypes, and biochemical signals. These interfaces, called entheses for ligaments, tendons, and the meniscus, are crucial to joint function, transferring mechanical loads and stabilizing orthopedic joints. When injuries occur to connected soft tissue, the enthesis must be re-established to restore function, but due to structural complexity, repair has proven challenging. Tissue engineering offers a promising solution for regenerating these tissues. This prospective review discusses methodologies for tissue engineering the enthesis, outlined in three key design inputs: materials processing methods, cellular contributions, and biochemical factors. PMID:29333332

  17. ISS Expedition 18 Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA) in Node 2

    NASA Image and Video Library

    2008-12-06

    ISS018-E-010645 (6 Dec. 2008) --- Astronaut Michael Fincke, Expedition 18 commander, works on the Multi-User Droplet Combustion Apparatus (MDCA) Chamber Insert Assembly (CIA) in the Harmony node of the International Space Station.

  18. Prototype design of a wearable metal hydride actuator using a soft bellows for motor rehabilitation.

    PubMed

    Ino, Shuichi; Sato, Mitsuru; Hosono, Minako; Nakajima, Sawako; Yamashita, Kazuhiko; Tanaka, Toshiaki; Izumi, Takashi

    2008-01-01

    A bedside and home rehabilitation system for people with motor disabilities due to stroke or the aging process requires a human-compatible actuator with softness, low noise and a high power-to-weight ratio. To achieve these types of joint motor rehabilitation systems, we designed a wearable metal hydride (MH) actuator using a soft bellows. The purpose of the current study is the development the soft and light bellows made of a polymer laminate film for the MH actuator. As a result of experimental tests, this soft bellows weighs 20 times less and stretches 30 times longer than the metal bellows used in a conventional MH actuator, and it has hydrogen impermeability, flex durability and adequate compliance for human joints. The MH actuator using the soft bellows can drive at a slow and safe enough speed for motor rehabilitation of patients' limbs. These preliminary findings support the efficacy of an MH actuator with a soft bellows for the purpose of developing a system for motor rehabilitation or human power assist.

  19. Socialisation for Learning at a Distance in a 3-D Multi-User Virtual Environment

    ERIC Educational Resources Information Center

    Edirisingha, Palitha; Nie, Ming; Pluciennik, Mark; Young, Ruth

    2009-01-01

    This paper reports findings of a pilot study that examined the pedagogical potential of "Second Life" (SL), a popular three-dimensional multi-user virtual environment (3-D MUVE) developed by the Linden Lab. The study is part of a 1-year research and development project titled "Modelling of Secondlife Environments"…

  20. A Soft Parallel Kinematic Mechanism.

    PubMed

    White, Edward L; Case, Jennifer C; Kramer-Bottiglio, Rebecca

    2018-02-01

    In this article, we describe a novel holonomic soft robotic structure based on a parallel kinematic mechanism. The design is based on the Stewart platform, which uses six sensors and actuators to achieve full six-degree-of-freedom motion. Our design is much less complex than a traditional platform, since it replaces the 12 spherical and universal joints found in a traditional Stewart platform with a single highly deformable elastomer body and flexible actuators. This reduces the total number of parts in the system and simplifies the assembly process. Actuation is achieved through coiled-shape memory alloy actuators. State observation and feedback is accomplished through the use of capacitive elastomer strain gauges. The main structural element is an elastomer joint that provides antagonistic force. We report the response of the actuators and sensors individually, then report the response of the complete assembly. We show that the completed robotic system is able to achieve full position control, and we discuss the limitations associated with using responsive material actuators. We believe that control demonstrated on a single body in this work could be extended to chains of such bodies to create complex soft robots.

  1. Biologically-inspired soft exosuit.

    PubMed

    Asbeck, Alan T; Dyer, Robert J; Larusson, Arnar F; Walsh, Conor J

    2013-06-01

    In this paper, we present the design and evaluation of a novel soft cable-driven exosuit that can apply forces to the body to assist walking. Unlike traditional exoskeletons which contain rigid framing elements, the soft exosuit is worn like clothing, yet can generate moments at the ankle and hip with magnitudes of 18% and 30% of those naturally generated by the body during walking, respectively. Our design uses geared motors to pull on Bowden cables connected to the suit near the ankle. The suit has the advantages over a traditional exoskeleton in that the wearer's joints are unconstrained by external rigid structures, and the worn part of the suit is extremely light, which minimizes the suit's unintentional interference with the body's natural biomechanics. However, a soft suit presents challenges related to actuation force transfer and control, since the body is compliant and cannot support large pressures comfortably. We discuss the design of the suit and actuation system, including principles by which soft suits can transfer force to the body effectively and the biological inspiration for the design. For a soft exosuit, an important design parameter is the combined effective stiffness of the suit and its interface to the wearer. We characterize the exosuit's effective stiffness, and present preliminary results from it generating assistive torques to a subject during walking. We envision such an exosuit having broad applicability for assisting healthy individuals as well as those with muscle weakness.

  2. Sediment Contaminants and Infauna Associated with Recreational Boating Structures in a Multi-Use Marine Park.

    PubMed

    Sim, Vivian X Y; Dafforn, Katherine A; Simpson, Stuart L; Kelaher, Brendan P; Johnston, Emma L

    2015-01-01

    Multi-use marine parks achieve conservation through spatial management of activities. Zoning of marine parks in New South Wales, Australia, includes high conservation areas and special purpose zones (SPZ) where maritime activities are concentrated. Although such measures geographically constrain anthropogenic impacts, we have limited understanding of potential ecological effects. We assessed sediment communities and contaminants adjacent to boating infrastructure (boat ramps, jetties and a marina) in a SPZ from the Clyde Estuary in Batemans Marine Park. Metal concentrations and fines content were elevated at boating structures compared to reference sites. Species richness was higher at sites with boating structures, where capitellid polychaetes and nematodes dominated the communities. Changes associated with boating structures were localised and did not extend beyond breakwalls or to reference sites outside the SPZ. The study highlights the benefits of appropriate zoning in a multi-use marine park and the potential to minimise stress on pristine areas through the application of spatial management.

  3. Sediment Contaminants and Infauna Associated with Recreational Boating Structures in a Multi-Use Marine Park

    PubMed Central

    Sim, Vivian X. Y.; Dafforn, Katherine A.; Simpson, Stuart L.; Kelaher, Brendan P.; Johnston, Emma L.

    2015-01-01

    Multi-use marine parks achieve conservation through spatial management of activities. Zoning of marine parks in New South Wales, Australia, includes high conservation areas and special purpose zones (SPZ) where maritime activities are concentrated. Although such measures geographically constrain anthropogenic impacts, we have limited understanding of potential ecological effects. We assessed sediment communities and contaminants adjacent to boating infrastructure (boat ramps, jetties and a marina) in a SPZ from the Clyde Estuary in Batemans Marine Park. Metal concentrations and fines content were elevated at boating structures compared to reference sites. Species richness was higher at sites with boating structures, where capitellid polychaetes and nematodes dominated the communities. Changes associated with boating structures were localised and did not extend beyond breakwalls or to reference sites outside the SPZ. The study highlights the benefits of appropriate zoning in a multi-use marine park and the potential to minimise stress on pristine areas through the application of spatial management. PMID:26086427

  4. The hindlimb in walking horses: 2. Net joint moments and joint powers.

    PubMed

    Clayton, H M; Hodson, E; Lanovaz, J L; Colborne, G R

    2001-01-01

    The objective of the study was to describe net joint moments and joint powers in the equine hindlimb during walking. The subjects were 5 sound horses. Kinematic and force data were collected synchronously and combined with morphometric information to determine net joint moments at each hindlimb joint throughout stance and swing. The results showed that the net joint moment was on the caudal/plantar side of all hindlimb joints at the start of stance when the limb was being actively retracted. It moved to the cranial/dorsal side around 24% stride at the hip and stifle and in terminal stance at the more distal joints. It remained on the cranial/dorsal side of all joints during the first half of swing to provide active limb protraction, then moved to the caudal/plantar aspect to reverse the direction of limb motion prior to ground contact. The hip joint was the main source of energy generation throughout the stride. It was assisted by the tarsal joint in both stance and swing phases and by the fetlock joint during the stance phase. The coffin joint acted as an energy damper during stance, whereas the stifle joint absorbed almost equal amounts of energy in the stance and swing phases. The coffin and fetlock joints absorbed energy as the limb was protracted and retracted during the swing phase, suggesting that their movements were driven by inertial forces. Future studies will apply these findings to detect changes in the energy profiles due to specific soft tissue injuries.

  5. Successful treatment of a guitarist with a finger joint injury using instrument-assisted soft tissue mobilization: a case report

    PubMed Central

    Terry Loghmani, M.; Bayliss, Amy J.; Clayton, Greg; Gundeck, Evelina

    2015-01-01

    Finger injuries are common and can greatly affect a musician’s quality of life. A 55-year-old man, who had injured the proximal interphalangeal joint of the left index finger 6 months prior to any intervention, was treated with a manual therapy approach incorporating instrument-assisted soft tissue mobilization (IASTM). Initial examination findings included self-reported pain and functional limitations and physical impairments that significantly impeded his ability to play the acoustic guitar. He was treated once a week for 6 weeks with IASTM, joint mobilization, therapeutic exercise, and ice massage. Additionally, a home exercise program and self-care instructions were provided. The patient gained positive outcomes with improvements in pain (Numerical Pain Rating Scale while playing the guitar: initial 5/10, discharge 1/10) and function (Disability Arm Shoulder Hand Sports-Performing Arts Optional Module: initial 75; discharge 6·25), each reaching a minimum clinically important difference. Importantly, he was able to play the guitar with minimal to no pain as desired. Physical measures also improved, including an immediate gain in finger range of motion with IASTM alone. Manual therapy approaches integrating IASTM may provide an effective conservative treatment strategy for patients with finger/hand conditions in the performing arts and other patient populations. PMID:26952165

  6. Background for Joint Systems Aspects of AIR 6000

    DTIC Science & Technology

    2000-04-01

    Checkland’s Soft Systems Methodology [7, 8,9]. The analytical techniques that are proposed for joint systems work are based on calculating probability...Supporting Global Interests 21 DSTO-CR-0155 SLMP Structural Life Management Plan SOW Stand-Off Weapon SSM Soft Systems Methodology UAV Uninhabited Aerial... Systems Methodology in Action, John Wiley & Sons, Chichester, 1990. [101 Pearl, Judea, Probabilistic Reasoning in Intelligent Systems: Networks of Plausible

  7. Melorheostosis with recurrent soft-tissue components: a histologically confirmed case.

    PubMed

    Hasegawa, Shoichi; Kanda, Shotaro; Imada, Hiroki; Yamaguchi, Takehiko; Akiyama, Toru

    2017-03-01

    Melorheostosis is a very rare disorder characterized by irregular cortical thickening seen on radiographs. In this paper, we present a case of melorheostosis with microscopically confirmed soft-tissue components. The patient was a 51-year-old man who complained of severe pain in the lateral aspect of his right knee. The excision of an ossified soft-tissue lesion relieved intractable pain that had lasted 20 years. Microscopically, the cortex of the affected fibula was composed of thick compact bone and the soft-tissue component consisted of dense compact bone without endochondral ossification. The presence of soft-tissue osseous nodules around the joints is one of the specific conditions for melorheostosis and should be differentiated from synovial chondromatosis. The ossified soft-tissue lesion in our patient is to our knowledge the first reported case of the histologically confirmed soft-tissue component of melorheostosis, which differs from that of synovial chondromatosis.

  8. Multiuser Collaboration with Networked Mobile Devices

    NASA Technical Reports Server (NTRS)

    Tso, Kam S.; Tai, Ann T.; Deng, Yong M.; Becks, Paul G.

    2006-01-01

    In this paper we describe a multiuser collaboration infrastructure that enables multiple mission scientists to remotely and collaboratively interact with visualization and planning software, using wireless networked personal digital assistants(PDAs) and other mobile devices. During ground operations of planetary rover and lander missions, scientists need to meet daily to review downlinked data and plan science activities. For example, scientists use the Science Activity Planner (SAP) in the Mars Exploration Rover (MER) mission to visualize downlinked data and plan rover activities during the science meetings [1]. Computer displays are projected onto large screens in the meeting room to enable the scientists to view and discuss downlinked images and data displayed by SAP and other software applications. However, only one person can interact with the software applications because input to the computer is limited to a single mouse and keyboard. As a result, the scientists have to verbally express their intentions, such as selecting a target at a particular location on the Mars terrain image, to that person in order to interact with the applications. This constrains communication and limits the returns of science planning. Furthermore, ground operations for Mars missions are fundamentally constrained by the short turnaround time for science and engineering teams to process and analyze data, plan the next uplink, generate command sequences, and transmit the uplink to the vehicle [2]. Therefore, improving ground operations is crucial to the success of Mars missions. The multiuser collaboration infrastructure enables users to control software applications remotely and collaboratively using mobile devices. The infrastructure includes (1) human-computer interaction techniques to provide natural, fast, and accurate inputs, (2) a communications protocol to ensure reliable and efficient coordination of the input devices and host computers, (3) an application

  9. Joint kinematics estimation using a multi-body kinematics optimisation and an extended Kalman filter, and embedding a soft tissue artefact model.

    PubMed

    Bonnet, Vincent; Richard, Vincent; Camomilla, Valentina; Venture, Gentiane; Cappozzo, Aurelio; Dumas, Raphaël

    2017-09-06

    To reduce the impact of the soft tissue artefact (STA) on the estimate of skeletal movement using stereophotogrammetric and skin-marker data, multi-body kinematics optimisation (MKO) and extended Kalman filters (EKF) have been proposed. This paper assessed the feasibility and efficiency of these methods when they embed a mathematical model of the STA and simultaneously estimate the ankle, knee and hip joint kinematics and the model parameters. A STA model was used that provides an estimate of the STA affecting the marker-cluster located on a body segment as a function of the kinematics of the adjacent joints. The MKO and the EKF were implemented with and without the STA model. To assess these methods, intra-cortical pin and skin markers located on the thigh, shank, and foot of three subjects and tracked during the stance phase of running were used. Embedding the STA model in MKO and EKF reduced the average RMS of marker tracking from 12.6 to 1.6mm and from 4.3 to 1.9mm, respectively, showing that a STA model trial-specific calibration is feasible. Nevertheless, with the STA model embedded in MKO, the RMS difference between the estimated and the reference joint kinematics determined from the pin markers slightly increased (from 2.0 to 2.1deg) On the contrary, when the STA model was embedded in the EKF, this RMS difference was slightly reduced (from 2.0 to 1.7deg) thus showing a better potentiality of this method to attenuate STA effects and improve the accuracy of joint kinematics estimate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. [Distal soft-tissue procedure in hallux valgus deformity].

    PubMed

    Arbab, D; Wingenfeld, C; Frank, D; Bouillon, B; König, D P

    2016-04-01

    Distal, lateral soft tissue release to restore mediolateral balance of the first metatarsophalangeal (MTP) joint in hallux valgus deformity. Incision of the adductor hallucis tendon from the fibular sesamoid, the lateral capsule, the lateral collateral ligament, and the lateral metatarsosesamoid ligament. Hallux valgus deformities or recurrent hallux valgus deformities with an incongruent MTP joint. General medical contraindications to surgical interventions. Painful stiffness of the MTP joint, osteonecrosis, congruent joint. Relative contraindications: connective tissue diseases (Marfan syndrome, Ehler-Danlos syndrome). Longitudinal, dorsal incision in the first intermetatarsal web space between the first and second MTP joint. Blunt dissection and identification of the adductor hallucis tendon. Release of the adductor tendon from the fibular sesamoid. Incision of the lateral capsule, the lateral collateral ligament, and the lateral metatarsosesamoid ligament. Postoperative management depends on bony correction. In joint-preserving procedures, dressing for 3 weeks in corrected position. Subsequently hallux valgus orthosis at night and a toe spreader for a further 3 months. Passive mobilization of the first MTP joint. Postoperative weight-bearing according to the osteotomy. A total of 31 patients with isolated hallux valgus deformity underwent surgery with a Chevron and Akin osteotomy and a distal medial and lateral soft tissue balancing. The mean preoperative intermetatarsal (IMA) angle was 12.3° (range 11-15°); the hallux valgus (HV) angle was 28.2° (25-36°). The mean follow-up was 16.4 months (range 12-22 months). The mean postoperative IMA correction ranged between 2 and 7° (mean 5.2°); the mean HV correction was 15.5° (range 9-21°). In all, 29 patients (93%) were satisfied or very satisfied with the postoperative outcome, while 2 patients (7%) were not satisfied due to one delayed wound healing and one recurrent hallux valgus deformity. There were no

  11. A Multi-User Virtual Environment for Building and Assessing Higher Order Inquiry Skills in Science

    ERIC Educational Resources Information Center

    Ketelhut, Diane Jass; Nelson, Brian C.; Clarke, Jody; Dede, Chris

    2010-01-01

    This study investigated novel pedagogies for helping teachers infuse inquiry into a standards-based science curriculum. Using a multi-user virtual environment (MUVE) as a pedagogical vehicle, teams of middle-school students collaboratively solved problems around disease in a virtual town called River City. The students interacted with "avatars" of…

  12. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    PubMed Central

    Amiri, Shahram; Wilson, David R.

    2012-01-01

    Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty. PMID:23082090

  13. Can a Soft Robotic Probe Use Stiffness Control Like a Human Finger to Improve Efficacy of Haptic Perception?

    PubMed

    Sornkarn, Nantachai; Nanayakkara, Thrishantha

    2017-01-01

    When humans are asked to palpate a soft tissue to locate a hard nodule, they regulate the stiffness, speed, and force of the finger during examination. If we understand the relationship between these behavioral variables and haptic information gain (transfer entropy) during manual probing, we can improve the efficacy of soft robotic probes for soft tissue palpation, such as in tumor localization in minimally invasive surgery. Here, we recorded the muscle co-contraction activity of the finger using EMG sensors to address the question as to whether joint stiffness control during manual palpation plays an important role in the haptic information gain. To address this question, we used a soft robotic probe with a controllable stiffness joint and a force sensor mounted at the base to represent the function of the tendon in a biological finger. Then, we trained a Markov chain using muscle co-contraction patterns of human subjects, and used it to control the stiffness of the soft robotic probe in the same soft tissue palpation task. The soft robotic experiments showed that haptic information gain about the depth of the hard nodule can be maximized by varying the internal stiffness of the soft probe.

  14. Hybrid Augmented Reality for Participatory Learning: The Hidden Efficacy of Multi-User Game-Based Simulation

    ERIC Educational Resources Information Center

    Oh, Seungjae; So, Hyo-Jeong; Gaydos, Matthew

    2018-01-01

    The goal for this research is to articulate and test a new hybrid Augmented Reality (AR) environment for conceptual understanding. From the theoretical lens of embodied interaction, we have designed a multi-user participatory simulation called ARfract where visitors in a science museum can learn about complex scientific concepts on the refraction…

  15. Authenticated multi-user quantum key distribution with single particles

    NASA Astrophysics Data System (ADS)

    Lin, Song; Wang, Hui; Guo, Gong-De; Ye, Guo-Hua; Du, Hong-Zhen; Liu, Xiao-Fen

    2016-03-01

    Quantum key distribution (QKD) has been growing rapidly in recent years and becomes one of the hottest issues in quantum information science. During the implementation of QKD on a network, identity authentication has been one main problem. In this paper, an efficient authenticated multi-user quantum key distribution (MQKD) protocol with single particles is proposed. In this protocol, any two users on a quantum network can perform mutual authentication and share a secure session key with the assistance of a semi-honest center. Meanwhile, the particles, which are used as quantum information carriers, are not required to be stored, therefore the proposed protocol is feasible with current technology. Finally, security analysis shows that this protocol is secure in theory.

  16. A "Second Life" for Gross Anatomy: Applications for Multiuser Virtual Environments in Teaching the Anatomical Sciences

    ERIC Educational Resources Information Center

    Richardson, April; Hazzard, Matthew; Challman, Sandra D.; Morgenstein, Aaron M.; Brueckner, Jennifer K.

    2011-01-01

    This article describes the emerging role of educational multiuser virtual environments, specifically Second Life[TM], in anatomical sciences education. Virtual worlds promote inquiry-based learning and conceptual understanding, potentially making them applicable for teaching and learning gross anatomy. A short introduction to Second Life as an…

  17. Design and Implementation of a 3D Multi-User Virtual World for Language Learning

    ERIC Educational Resources Information Center

    Ibanez, Maria Blanca; Garcia, Jose Jesus; Galan, Sergio; Maroto, David; Morillo, Diego; Kloos, Carlos Delgado

    2011-01-01

    The best way to learn is by having a good teacher and the best language learning takes place when the learner is immersed in an environment where the language is natively spoken. 3D multi-user virtual worlds have been claimed to be useful for learning, and the field of exploiting them for education is becoming more and more active thanks to the…

  18. Multi-User Spaceport Update News Conference

    NASA Image and Video Library

    2014-01-23

    CAPE CANAVERAL, Fla. – Larry Price, Lockheed Martin Space Systems deputy program manager for NASA's Orion spacecraft, joins Sierra Nevada Corporation, or SNC, Space Systems, as the company announces the steps it will take to prepare for a November 2016 orbital flight of its Dream Chaser spacecraft from Florida’s Space Coast. The steps are considered substantial for SNC and important to plans by NASA and Space Florida for Kennedy Space Center’s transformation into a multi-user spaceport for both commercial and government customers. SNC said it plans to work with United Launch Alliance, or ULA, to launch the Dream Chaser spacecraft into orbit atop an Atlas V rocket from Space Launch Complex 41 at Cape Canaveral Air Force Station intends to land the winged spacecraft at Kennedy’s 3.5-mile long runway at the Shuttle Landing Facility lease office space at Exploration Park, right outside Kennedy’s gates and process the spacecraft in the high bay of the Operations and Checkout Building at Kennedy, with Lockheed Martin performing the work. Photo credit: NASA/Kim Shiflett

  19. Multi-User Spaceport Update News Conference

    NASA Image and Video Library

    2014-01-23

    CAPE CANAVERAL, Fla. – Frank DiBello, right, president and CEO of Space Florida, joins Sierra Nevada Corporation, or SNC, Space Systems, as the company announces the steps it will take to prepare for a November 2016 orbital flight of its Dream Chaser spacecraft from Florida’s Space Coast. The steps are considered substantial for SNC and important to plans by NASA and Space Florida for Kennedy Space Center’s transformation into a multi-user spaceport for both commercial and government customers. SNC said it plans to work with United Launch Alliance, or ULA, to launch the Dream Chaser spacecraft into orbit atop an Atlas V rocket from Space Launch Complex 41 at Cape Canaveral Air Force Station intends to land the winged spacecraft at Kennedy’s 3.5-mile long runway at the Shuttle Landing Facility lease office space at Exploration Park, right outside Kennedy’s gates and process the spacecraft in the high bay of the Operations and Checkout Building at Kennedy, with Lockheed Martin performing the work. Photo credit: NASA/Kim Shiflett

  20. Recent advances in computational mechanics of the human knee joint.

    PubMed

    Kazemi, M; Dabiri, Y; Li, L P

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling.

  1. A pilot study on the improvement of the lying area of finishing pigs by a soft lying mat.

    PubMed

    Savary, Pascal; Gygax, Lorenz; Jungbluth, Thomas; Wechsler, Beat; Hauser, Rudolf

    2011-01-01

    In this pilot study, we tested whether a soft mat (foam covered with a heat-sealed thermoplastic) reduces alterations and injuries at the skin and the leg joints.The soft mat in the lying area of partly slatted pens was compared to a lying area consisting of either bare or slightly littered (100 g straw per pig and day) concrete flooring. In this study we focused on skin lesions on the legs of finishing pigs as indicators of impaired welfare. Pigs were kept in 19 groups of 8-10 individuals and were examined for skin lesions around the carpal and tarsal joints either at a weight of <35 kg, or at close to 100 kg. The likelihood of hairless patches and wounds at the tarsal joints was significantly lower in pens with the soft lying mat than in pens with a bare concrete floor. Pens with a littered concrete floor did not differ compared to pens with a bare concrete floor. The soft lying mat thus improved floor quality in the lying area in terms of preventing skin lesions compared to bare and slightly littered concrete flooring. Such soft lying mats have thus the potential to improve lying comfort and welfare of finishing pigs.

  2. Multi-User Domain Object Oriented (MOO) as a High School Procedure for Foreign Language Acquisition.

    ERIC Educational Resources Information Center

    Backer, James A.

    Foreign language students experience added difficulty when they are isolated from native speakers and from the culture of the target language. It has been posited that MOO (Multi-User Domain Object Oriented) may help overcome the geographical isolation of these students. MOOs are Internet-based virtual worlds in which people from all over the real…

  3. Exploring the Integration of Technology into Jewish Education: Multi-User Virtual Environments and Supplementary School Settings

    ERIC Educational Resources Information Center

    Sohn, Johannah Eve

    2014-01-01

    This descriptive case study explores the implementation of a multi-user virtual environment (MUVE) in a Jewish supplemental school setting. The research was conducted to present the recollections and reflections of three constituent populations of a new technology exploring constructivist education in the context of supplemental and online…

  4. Talbot phase-contrast X-ray imaging for the small joints of the hand

    PubMed Central

    Stutman, Dan; Beck, Thomas J; Carrino, John A; Bingham, Clifton O

    2011-01-01

    A high resolution radiographic method for soft tissues in the small joints of the hand would aid in the study and treatment of Rheumatoid Arthritis (RA) and Osteoarthritis (OA), which often attacks these joints. Of particular interest would be imaging with <100 μm resolution the joint cartilage, whose integrity is a main indicator of disease. Differential phase-contrast or refraction based X-ray imaging (DPC) with Talbot grating interferometers could provide such a method, since it enhances soft tissue contrast and it can be implemented with conventional X-ray tubes. A numerical joint phantom was first developed to assess the angular sensitivity and spectrum needed for a hand DPC system. The model predicts that due to quite similar refraction indexes for joint soft tissues, the refraction effects are very small, requiring high angular resolution. To compare our model to experiment we built a high resolution bench-top interferometer using 10 μm period gratings, a W anode tube and a CCD based detector. Imaging experiments on animal cartilage and on a human finger support the model predictions. For instance, the estimated difference between the index of refraction of cartilage and water is of only several percent at ~25 keV mean energy, comparable to that between the linear attenuation coefficients. The potential advantage of DPC imaging comes thus mainly from the edge enhancement at the soft tissue interfaces. Experiments using a cadaveric human finger are also qualitatively consistent with the joint model, showing that refraction contrast is dominated by tendon embedded in muscle, with the cartilage layer difficult to observe in our conditions. Nevertheless, the model predicts that a DPC radiographic system for the small hand joints of the hand could be feasible using a low energy quasi-monochromatic source, such as a K-edge filtered Rh or Mo tube, in conjunction with a ~2 m long ‘symmetric’ interferometer operated in a high Talbot order. PMID:21841214

  5. Talbot phase-contrast x-ray imaging for the small joints of the hand

    NASA Astrophysics Data System (ADS)

    Stutman, Dan; Beck, Thomas J.; Carrino, John A.; Bingham, Clifton O.

    2011-09-01

    A high-resolution radiographic method for soft tissues in the small joints of the hand would aid in the study and treatment of rheumatoid arthritis (RA) and osteoarthritis (OA), which often attacks these joints. Of particular interest would be imaging with <100 µm resolution the joint cartilage, whose integrity is a main indicator of disease. Differential phase-contrast (DPC) or refraction-based x-ray imaging with Talbot grating interferometers could provide such a method, since it enhances soft tissue contrast and can be implemented with conventional x-ray tubes. A numerical joint phantom was first developed to assess the angular sensitivity and spectrum needed for a hand DPC system. The model predicts that, due to quite similar refraction indexes for joint soft tissues, the refraction effects are very small, requiring high angular resolution. To compare our model to experiment we built a high-resolution bench-top interferometer using 10 µm period gratings, a W anode tube and a CCD-based detector. Imaging experiments on animal cartilage and on a human finger support the model predictions. For instance, the estimated difference between the index of refraction of cartilage and water is of only several percent at ~25 keV mean energy, comparable to that between the linear attenuation coefficients. The potential advantage of DPC imaging thus comes mainly from the edge enhancement at the soft tissue interfaces. Experiments using a cadaveric human finger are also qualitatively consistent with the joint model, showing that refraction contrast is dominated by tendon embedded in muscle, with the cartilage layer difficult to observe in our conditions. Nevertheless, the model predicts that a DPC radiographic system for the small hand joints of the hand could be feasible using a low energy quasi-monochromatic source, such as a K-edge filtered Rh or Mo tube, in conjunction with a ~2 m long 'symmetric' interferometer operated in a high Talbot order.

  6. Arthroscopic debridement for soft tissue ankle impingement.

    PubMed

    Brennan, S A; Rahim, F; Dowling, J; Kearns, S R

    2012-06-01

    To assess the response to treatment in patients with soft tissue impingement of the ankle managed with arthroscopic debridement. Forty-one ankle arthroscopies were performed for soft tissue impingement between April 2007 and April 2009. There were 26 men and 15 women and the mean age was 30.1 years. Arthroscopy was performed on an average of 21 months after injury. The Visual-Analogue-Scale Foot and Ankle (VASFA) score and Meislin's criteria were used to assess the response to treatment. The mean pre-operative VASFA score was 44.5. This increased to 78.3 postoperatively (p < 0.0001). According to Meislin's criteria, there were 34 good or excellent results, five fair and two poor results. Pre-operative magnetic resonance imaging was useful in detecting tears of the anterior talofibular ligament and excluding osteochondral defects; however, synovitis and soft tissue impingement was under-reported. Arthroscopy is an effective method for the diagnoses and treatment of soft tissue impingement of the ankle joint. This condition is under-reported on MRI.

  7. DEMES rotary joint: theories and applications

    NASA Astrophysics Data System (ADS)

    Wang, Shu; Hao, Zhaogang; Li, Mingyu; Huang, Bo; Sun, Lining; Zhao, Jianwen

    2017-04-01

    As a kind of dielectric elastomer actuators, dielectric elastomer minimum energy structure (DEMES) can realize large angular deformations by small voltage-induced strains, which make them an attractive candidate for use as biomimetic robotics. Considering the rotary joint is a basic and common component of many biomimetic robots, we have been fabricated rotary joint by DEMES and developed its performances in the past two years. In this paper, we have discussed the static analysis, dynamics analysis and some characteristics of the DEMES rotary joint. Based on theoretical analysis, some different applications of the DEMES rotary joint were presented, such as a flapping wing, a biomimetic fish and a two-legged walker. All of the robots are fabricated by DEMES rotary joint and can realize some basic biomimetic motions. Comparing with traditional rigid robot, the robot based on DEMES is soft and light, so it has advantage on the collision-resistant.

  8. Robust Transceiver Design for Multiuser MIMO Downlink with Channel Uncertainties

    NASA Astrophysics Data System (ADS)

    Miao, Wei; Li, Yunzhou; Chen, Xiang; Zhou, Shidong; Wang, Jing

    This letter addresses the problem of robust transceiver design for the multiuser multiple-input-multiple-output (MIMO) downlink where the channel state information at the base station (BS) is imperfect. A stochastic approach which minimizes the expectation of the total mean square error (MSE) of the downlink conditioned on the channel estimates under a total transmit power constraint is adopted. The iterative algorithm reported in [2] is improved to handle the proposed robust optimization problem. Simulation results show that our proposed robust scheme effectively reduces the performance loss due to channel uncertainties and outperforms existing methods, especially when the channel errors of the users are different.

  9. Recent Advances in Computational Mechanics of the Human Knee Joint

    PubMed Central

    Kazemi, M.; Dabiri, Y.; Li, L. P.

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling. PMID:23509602

  10. Robots, multi-user virtual environments and healthcare: synergies for future directions.

    PubMed

    Moon, Ajung; Grajales, Francisco J; Van der Loos, H F Machiel

    2011-01-01

    The adoption of technology in healthcare over the last twenty years has steadily increased, particularly as it relates to medical robotics and Multi-User Virtual Environments (MUVEs) such as Second Life. Both disciplines have been shown to improve the quality of care and have evolved, for the most part, in isolation from each other. In this paper, we present four synergies between medical robotics and MUVEs that have the potential to decrease resource utilization and improve the quality of healthcare delivery. We conclude with some foreseeable barriers and future research directions for researchers in these fields.

  11. A software for managing chemical processes in a multi-user laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Camino, Fernando E.

    Here, we report a software for logging chemical processes in a multi-user laboratory, which implements a work flow designed to reduce hazardous situations associated with the disposal of chemicals in incompatible waste containers. The software allows users to perform only those processes displayed in their list of authorized chemical processes and provides the location and label code of waste containers, among other useful information. The software has been used for six years in the cleanroom of the Center for Functional Nanomaterials at Brookhaven National Laboratory and has been an important factor for the excellent safety record of the Center.

  12. A software for managing chemical processes in a multi-user laboratory

    DOE PAGES

    Camino, Fernando E.

    2016-10-26

    Here, we report a software for logging chemical processes in a multi-user laboratory, which implements a work flow designed to reduce hazardous situations associated with the disposal of chemicals in incompatible waste containers. The software allows users to perform only those processes displayed in their list of authorized chemical processes and provides the location and label code of waste containers, among other useful information. The software has been used for six years in the cleanroom of the Center for Functional Nanomaterials at Brookhaven National Laboratory and has been an important factor for the excellent safety record of the Center.

  13. Transverse momentum resummation in soft collinear effective theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao Yang; Li Chongsheng; Liu Jianjun

    We present a universal formalism for transverse momentum resummation in the view of soft-collinear effective theory (SCET), and establish the relation between our SCET formula and the well known Collins-Soper-Sterman's pQCD formula at the next-to-leading logarithmic order (NLLO). We also briefly discuss the reformulation of joint resummation in SCET.

  14. Wide temperature range seal for demountable joints

    DOEpatents

    Sixsmith, Herbert; Valenzuela, Javier A.; Nutt, William E.

    1991-07-23

    The present invention is directed to a seal for demountable joints operating over a wide temperature range down to liquid helium temperatures. The seal has anti-extrusion guards which prevent extrusion of the soft ductile sealant material, which may be indium or an alloy thereof.

  15. Evaluation of traction stirrup distraction technique to increase the joint space of the shoulder joint in the dog: A cadaveric study.

    PubMed

    Devesa, V; Rovesti, G L; Urrutia, P G; Sanroman, F; Rodriguez-Quiros, J

    2015-06-01

    The objective of this study was to evaluate technical feasibility and efficacy of a joint distraction technique by traction stirrup to facilitate shoulder arthroscopy and assess potential soft tissue damage. Twenty shoulders were evaluated radiographically before distraction. Distraction was applied with loads from 40 N up to 200 N, in 40 N increments, and the joint space was recorded at each step by radiographic images. The effects of joint flexion and intra-articular air injection at maximum load were evaluated. Radiographic evaluation was performed after distraction to evaluate ensuing joint laxity. Joint distraction by traction stirrup technique produces a significant increase in the joint space; an increase in joint laxity could not be inferred by standard and stress radiographs. However, further clinical studies are required to evaluate potential neurovascular complications. A wider joint space may be useful to facilitate arthroscopy, reducing the likelihood for iatrogenic damage to intra-articular structures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Advancing MEMS Technology Usage through the MUMPS (Multi-User MEMS Processes) Program

    NASA Technical Reports Server (NTRS)

    Koester, D. A.; Markus, K. W.; Dhuler, V.; Mahadevan, R.; Cowen, A.

    1995-01-01

    In order to help provide access to advanced micro-electro-mechanical systems (MEMS) technologies and lower the barriers for both industry and academia, the Microelectronic Center of North Carolina (MCNC) and ARPA have developed a program which provides users with access to both MEMS processes and advanced electronic integration techniques. The four distinct aspects of this program, the multi-user MEMS processes (MUMP's), the consolidated micro-mechanical element library, smart MEMS, and the MEMS technology network are described in this paper. MUMP's is an ARPA-supported program created to provide inexpensive access to MEMS technology in a multi-user environment. It is both a proof-of-concept and educational tool that aids in the development of MEMS in the domestic community. MUMP's technologies currently include a 3-layer poly-silicon surface micromachining process and LIGA (lithography, electroforming, and injection molding) processes that provide reasonable design flexibility within set guidelines. The consolidated micromechanical element library (CaMEL) is a library of active and passive MEMS structures that can be downloaded by the MEMS community via the internet. Smart MEMS is the development of advanced electronics integration techniques for MEMS through the application of flip chip technology. The MEMS technology network (TechNet) is a menu of standard substrates and MEMS fabrication processes that can be purchased and combined to create unique process flows. TechNet provides the MEMS community greater flexibility and enhanced technology accessibility.

  17. Clinical and radiographic study of bone and joint lesions in 26 dogs with leishmaniasis.

    PubMed

    Agut, A; Corzo, N; Murciano, J; Laredo, F G; Soler, M

    2003-11-22

    Twenty-six dogs with parasitologically confirmed leishmaniasis and abnormalities of gait were studied to determine the most common radiological patterns of bone and joint lesions. The clinical findings included either lameness, joint pain and crepitation, soft tissue swelling and/or muscle atrophy. Bone lesions were observed radiographically in 12 of the 26 dogs; the radius and ulna were affected in seven, the tibia in six and the femur in six. Joint lesions were observed radiographically in 15 of the 26 dogs; the carpus and stifle were affected in all 15, and the tarsus in nine. There was a tendency for the bones and joints to be affected bilaterally. The radiographic patterns observed were different in the long bones and the joints. In the long bones, the most common pattern was periosteal and intramedullary proliferation, involving the diaphyses and related to the nutrient foramen; in the joints, two patterns, either non-erosive or erosive polyarthritis with soft-tissue swelling, were observed. The changes observed in the synovial fluid were associated in most cases with osteolytic lesions. However, Leishmania organisms were identified in the synovial fluid from joints without bony radiographic changes.

  18. Support vector machine multiuser receiver for DS-CDMA signals in multipath channels.

    PubMed

    Chen, S; Samingan, A K; Hanzo, L

    2001-01-01

    The problem of constructing an adaptive multiuser detector (MUD) is considered for direct sequence code division multiple access (DS-CDMA) signals transmitted through multipath channels. The emerging learning technique, called support vector machines (SVM), is proposed as a method of obtaining a nonlinear MUD from a relatively small training data block. Computer simulation is used to study this SVM MUD, and the results show that it can closely match the performance of the optimal Bayesian one-shot detector. Comparisons with an adaptive radial basis function (RBF) MUD trained by an unsupervised clustering algorithm are discussed.

  19. Wide temperature range seal for demountable joints

    DOEpatents

    Sixsmith, H.; Valenzuela, J.A.; Nutt, W.E.

    1991-07-23

    The present invention is directed to a seal for demountable joints operating over a wide temperature range down to liquid helium temperatures. The seal has anti-extrusion guards which prevent extrusion of the soft ductile sealant material, which may be indium or an alloy thereof. 6 figures.

  20. Soft connectedness of soft topological space

    NASA Astrophysics Data System (ADS)

    Mishra, Sanjay

    2017-07-01

    Recently, Shabir and Naz in [4] introduced the notion of Soft Topological Spaces (STS). They defined and studied about soft topology on the collection τ of soft sets over X. After the initiation of soft topological space many researcher developed its basic theory as like soft continuity, soft compactness and soft countability. Our main objective in this paper is to study the soft connectedness properties of soft topological space and also establish relations of soft connectedness with other properties of STS.

  1. Reconstructive surgery for patellofemoral joint incongruency.

    PubMed

    Neumann, M V; Stalder, M; Schuster, A J

    2016-03-01

    A retrospective analysis of a heterogeneous patient cohort was performed to determine the outcome and eligibility of a combined trochleaplasty and soft tissue-balancing technique for repair of patellofemoral joint disorders. A strict surgical treatment algorithm including trochleaplasty and reconstruction of the medial patellofemoral ligament and vastus medialis oblique muscle was implemented to restore the patellofemoral joint. A heterogeneous patient cohort including 46 consecutively treated symptomatic knees was reviewed. The median follow-up period was 4.7 years (range 24-109 months). No patellar redislocation occurred post-operatively, and the median Kujala score improved from 62 (9-96) to 88 (47-100) points (p < 0.001) at follow-up. Radiological signs of trochlear dysplasia were corrected, and both patellar height and trochlear depth were significantly restored after surgery. In total, 16% of affected patients with pre-existing patellofemoral degenerative changes showed progression of osteoarthrosis according to the Kellgren and Lawrence classification. The surgical combination of trochleaplasty and reconstruction of the medial patellofemoral ligament and vastus medialis oblique muscle offers excellent clinical and radiological results. The overall results of the present study showed significant improvement of the Kujala score in patients with Dejour grades C and D dysplasia. These results outline the clinical relevance of trochleaplasty with additional soft tissue balancing as an effective joint-preserving method with satisfying results in patients with pre-existing degenerative changes. IV.

  2. Negative pressure wound therapy for the treatment of infected wounds with exposed knee joint after patellar fracture.

    PubMed

    Lee, Sang Yang; Niikura, Takahiro; Miwa, Masahiko; Sakai, Yoshitada; Oe, Keisuke; Fukazawa, Takahiro; Kawakami, Yohei; Kurosaka, Masahiro

    2011-06-14

    Treatment of soft tissue defects with exposed bones and joints, resulting from trauma, infection, and surgical complications, represents a major challenge. The introduction of negative pressure wound therapy has changed many wound management practices. Negative pressure wound therapy has recently been used in the orthopedic field for management of traumatic or open wounds with exposed bone, nerve, tendon, and orthopedic implants. This article describes a case of a patient with a large soft tissue defect and exposed knee joint, in which negative pressure wound therapy markedly improved wound healing. A 50-year-old man presented with an ulceration of his left knee with exposed joint, caused by severe wound infections after open reduction and internal fixation of a patellar fracture. After 20 days of negative pressure wound therapy, a granulated wound bed covered the exposed bones and joint.To our knowledge, this is the first report of negative pressure wound therapy used in a patient with a large soft tissue defect with exposed knee joint. Despite the chronic wound secondary to infection, healing was achieved through the use of the negative pressure wound therapy, thus promoting granulation tissue formation and closing the joint. We suggest negative pressure wound therapy as an alternative option for patients with lower limb wounds containing exposed bones and joints when free flap transfer is contraindicated. Our result added to the growing evidence that negative pressure wound therapy is a useful adjunctive treatment for open wounds around the knee joint. Copyright 2011, SLACK Incorporated.

  3. Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation.

    PubMed

    Frick, Eric; Rahmatalla, Salam

    2018-04-04

    The biomechanical models used to refine and stabilize motion capture processes are almost invariably driven by joint center estimates, and any errors in joint center calculation carry over and can be compounded when calculating joint kinematics. Unfortunately, accurate determination of joint centers is a complex task, primarily due to measurements being contaminated by soft-tissue artifact (STA). This paper proposes a novel approach to joint center estimation implemented via sequential application of single-frame optimization (SFO). First, the method minimizes the variance of individual time frames’ joint center estimations via the developed variance minimization method to obtain accurate overall initial conditions. These initial conditions are used to stabilize an optimization-based linearization of human motion that determines a time-varying joint center estimation. In this manner, the complex and nonlinear behavior of human motion contaminated by STA can be captured as a continuous series of unique rigid-body realizations without requiring a complex analytical model to describe the behavior of STA. This article intends to offer proof of concept, and the presented method must be further developed before it can be reasonably applied to human motion. Numerical simulations were introduced to verify and substantiate the efficacy of the proposed methodology. When directly compared with a state-of-the-art inertial method, SFO reduced the error due to soft-tissue artifact in all cases by more than 45%. Instead of producing a single vector value to describe the joint center location during a motion capture trial as existing methods often do, the proposed method produced time-varying solutions that were highly correlated ( r > 0.82) with the true, time-varying joint center solution.

  4. Characterizing Student Navigation in Educational Multiuser Virtual Environments: A Case Study Using Data from the River City Project

    ERIC Educational Resources Information Center

    Dukas, Georg

    2009-01-01

    Though research in emerging technologies is vital to fulfilling their incredible potential for educational applications, it is often fraught with analytic challenges related to large datasets. This thesis explores these challenges in researching multiuser virtual environments (MUVEs). In a MUVE, users assume a persona and traverse a virtual space…

  5. Soft-Tissue Reconstruction of the Complicated Knee Arthroplasty: Principles and Predictors of Salvage.

    PubMed

    Colen, David L; Carney, Martin J; Shubinets, Valeriy; Lanni, Michael A; Liu, Tiffany; Levin, L Scott; Lee, Gwo-Chin; Kovach, Stephen J

    2018-04-01

    Total knee arthroplasty is a common orthopedic procedure in the United States and complications can be devastating. Soft-tissue compromise or joint infection may cause failure of prosthesis requiring knee fusion or amputation. The role of a plastic surgeon in total knee arthroplasty is critical for cases requiring optimization of the soft-tissue envelope. The purpose of this study was to elucidate factors associated with total knee arthroplasty salvage following complications and clarify principles of reconstruction to optimize outcomes. A retrospective review of patients requiring soft-tissue reconstruction performed by the senior author after total knee arthroplasty over 8 years was completed. Logistic regression and Fisher's exact tests determined factors associated with the primary outcome, prosthesis salvage versus knee fusion or amputation. Seventy-three knees in 71 patients required soft-tissue reconstruction (mean follow-up, 1.8 years), with a salvage rate of 61.1 percent, mostly using medial gastrocnemius flaps. Patients referred to our institution with complicated periprosthetic wounds were significantly more likely to lose their knee prosthesis than patients treated only within our system. Patients with multiple prior knee operations before definitive soft-tissue reconstruction had significantly decreased rates of prosthesis salvage and an increased risk of amputation. Knee salvage significantly decreased with positive joint cultures (Gram-negative greater than Gram-positive organisms) and particularly at the time of definitive reconstruction, which also trended toward an increased risk of amputation. In revision total knee arthroplasty, prompt soft-tissue reconstruction improves the likelihood of success, and protracted surgical courses and contamination increase failure and amputations. The authors show a benefit to involving plastic surgeons early in the course of total knee arthroplasty complications to optimize genicular soft tissues. Therapeutic

  6. FBMC receiver for multi-user asynchronous transmission on fragmented spectrum

    NASA Astrophysics Data System (ADS)

    Doré, Jean-Baptiste; Berg, Vincent; Cassiau, Nicolas; Kténas, Dimitri

    2014-12-01

    Relaxed synchronization and access to fragmented spectrum are considered for future generations of wireless networks. Frequency division multiple access for filter bank multicarrier (FBMC) modulation provides promising performance without strict synchronization requirements contrary to conventional orthogonal frequency division multiplexing (OFDM). The architecture of a FBMC receiver suitable for this scenario is considered. Carrier frequency offset (CFO) compensation is combined with intercarrier interference (ICI) cancellation and performs well under very large frequency offsets. Channel estimation and interpolation had to be adapted and proved effective even for heavily fragmented spectrum usage. Channel equalization can sustain large delay spread. Because all the receiver baseband signal processing functionalities are proposed in the frequency domain, the overall architecture is suitable for multiuser asynchronous transmission on fragmented spectrum.

  7. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  8. Temporomandibular Joint Imaging.

    PubMed

    Tamimi, Dania; Jalali, Elnaz; Hatcher, David

    2018-01-01

    The temporomandibular joint (TMJ) is an anatomically and biomechanically complex structure. Understanding how this structure grows and functions is essential to accurate radiographic evaluation. This article discusses the anatomy, function, and growth and development of the TMJ and how growth changes can affect the morphology of the craniofacial structures. Accordingly, the radiographic appearance of the entities that may alter the TMJ are discussed, including developmental, degenerative, inflammatory, and traumatic changes. Both osseous imaging and soft tissue imaging are shown. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Soft-rigid interaction mechanism towards a lobster-inspired hybrid actuator

    NASA Astrophysics Data System (ADS)

    Chen, Yaohui; Wan, Fang; Wu, Tong; Song, Chaoyang

    2018-01-01

    Soft pneumatic actuators (SPAs) are intrinsically light-weight, compliant and therefore ideal to directly interact with humans and be implemented into wearable robotic devices. However, they also pose new challenges in describing and sensing their continuous deformation. In this paper, we propose a hybrid actuator design with bio-inspirations from the lobsters, which can generate reconfigurable bending movements through the internal soft chamber interacting with the external rigid shells. This design with joint and link structures enables us to exactly track its bending configurations that previously posed a significant challenge to soft robots. Analytic models are developed to illustrate the soft-rigid interaction mechanism with experimental validation. A robotic glove using hybrid actuators to assist grasping is assembled to illustrate their potentials in safe human-robot interactions. Considering all the design merits, our work presents a practical approach to the design of next-generation robots capable of achieving both good accuracy and compliance.

  10. General-purpose interface bus for multiuser, multitasking computer system

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R.; Roth, Don J.; Stang, David B.

    1990-01-01

    The architecture of a multiuser, multitasking, virtual-memory computer system intended for the use by a medium-size research group is described. There are three central processing units (CPU) in the configuration, each with 16 MB memory, and two 474 MB hard disks attached. CPU 1 is designed for data analysis and contains an array processor for fast-Fourier transformations. In addition, CPU 1 shares display images viewed with the image processor. CPU 2 is designed for image analysis and display. CPU 3 is designed for data acquisition and contains 8 GPIB channels and an analog-to-digital conversion input/output interface with 16 channels. Up to 9 users can access the third CPU simultaneously for data acquisition. Focus is placed on the optimization of hardware interfaces and software, facilitating instrument control, data acquisition, and processing.

  11. Knee joint kinematics and kinetics during the hop and cut after soft tissue artifact suppression: Time to reconsider ACL injury mechanisms?

    PubMed

    Smale, Kenneth B; Potvin, Brigitte M; Shourijeh, Mohammad S; Benoit, Daniel L

    2017-09-06

    The recent development of a soft tissue artifact (STA) suppression method allows us to re-evaluate the tibiofemoral kinematics currently linked to non-contact knee injuries. The purpose of this study was therefore to evaluate knee joint kinematics and kinetics in six degrees of freedom (DoF) during the loading phases of a jump lunge and side cut using this in silico method. Thirty-five healthy adults completed these movements and their surface marker trajectories were then scaled and processed with OpenSim's inverse kinematics (IK) and inverse dynamics tools. Knee flexion angle-dependent kinematic constraints defined based on previous bone pin (BP) marker trajectories were then applied to the OpenSim model during IK and these constrained results were then processed with the standard inverse dynamics tool. Significant differences for all hip, knee, and ankle DoF were observed after STA suppression for both the jump lunge and side cut. Using clinically relevant effect size estimates, we conclude that STA contamination had led to misclassifications in hip transverse plane angles, knee frontal and transverse plane angles, medial/lateral and distractive/compressive knee translations, and knee frontal plane moments between the NoBP and the BP IK solutions. Our results have substantial clinical implications since past research has used joint kinematics and kinetics contaminated by STA to identify risk factors for musculoskeletal injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. The influence of intraoperative soft tissue balance on patellar pressure in posterior-stabilized total knee arthroplasty.

    PubMed

    Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-06-01

    Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Bilinear modeling of EMG signals to extract user-independent features for multiuser myoelectric interface.

    PubMed

    Matsubara, Takamitsu; Morimoto, Jun

    2013-08-01

    In this study, we propose a multiuser myoelectric interface that can easily adapt to novel users. When a user performs different motions (e.g., grasping and pinching), different electromyography (EMG) signals are measured. When different users perform the same motion (e.g., grasping), different EMG signals are also measured. Therefore, designing a myoelectric interface that can be used by multiple users to perform multiple motions is difficult. To cope with this problem, we propose for EMG signals a bilinear model that is composed of two linear factors: 1) user dependent and 2) motion dependent. By decomposing the EMG signals into these two factors, the extracted motion-dependent factors can be used as user-independent features. We can construct a motion classifier on the extracted feature space to develop the multiuser interface. For novel users, the proposed adaptation method estimates the user-dependent factor through only a few interactions. The bilinear EMG model with the estimated user-dependent factor can extract the user-independent features from the novel user data. We applied our proposed method to a recognition task of five hand gestures for robotic hand control using four-channel EMG signals measured from subject forearms. Our method resulted in 73% accuracy, which was statistically significantly different from the accuracy of standard nonmultiuser interfaces, as the result of a two-sample t -test at a significance level of 1%.

  14. The right view from the wrong location: depth perception in stereoscopic multi-user virtual environments.

    PubMed

    Pollock, Brice; Burton, Melissa; Kelly, Jonathan W; Gilbert, Stephen; Winer, Eliot

    2012-04-01

    Stereoscopic depth cues improve depth perception and increase immersion within virtual environments (VEs). However, improper display of these cues can distort perceived distances and directions. Consider a multi-user VE, where all users view identical stereoscopic images regardless of physical location. In this scenario, cues are typically customized for one "leader" equipped with a head-tracking device. This user stands at the center of projection (CoP) and all other users ("followers") view the scene from other locations and receive improper depth cues. This paper examines perceived depth distortion when viewing stereoscopic VEs from follower perspectives and the impact of these distortions on collaborative spatial judgments. Pairs of participants made collaborative depth judgments of virtual shapes viewed from the CoP or after displacement forward or backward. Forward and backward displacement caused perceived depth compression and expansion, respectively, with greater compression than expansion. Furthermore, distortion was less than predicted by a ray-intersection model of stereo geometry. Collaboration times were significantly longer when participants stood at different locations compared to the same location, and increased with greater perceived depth discrepancy between the two viewing locations. These findings advance our understanding of spatial distortions in multi-user VEs, and suggest a strategy for reducing distortion.

  15. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    PubMed

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  16. Performance of Improved Channel Allocation for Multicarrier CDMA with Adaptive Frequency Hopping and Multiuser Detection

    DTIC Science & Technology

    2008-08-29

    resulting in much larger system capacity than for a non-adaptive MC direct-sequence ( DS )- CDMA system. This conclusion is confirmed for realistic fading...system capacity than for a non-adaptive MC direct-sequence ( DS )- CDMA system. This conclusion is confirmed for realistic fading channels with correlated...transmission method exploits both frequency and multiuser diversity and improves on non-adaptive MC DS - CDMA sys- tems in [6]. In this paper, we focus on the

  17. Alteration and Implementation of the CP/M-86 Operating System for a Multi-User Environment.

    DTIC Science & Technology

    1982-12-01

    THE CP/M-86 OPERATING SYSTEM FOR A MULTI-USER ENVIRONMENT by Thomas V. Almquist and David S. Stevens C-, December 1982 ,LU Thesis Advisor : U. R. Kodres...tool$ 044, robo O0eA 6^900091 Approved for public release; distribution unlimited Alteration and Implementation of the CP/M-86 Operating System for a...SCIENCE IN COMPUTER SCIENCE from the NAVAL POSTGRADUATE SCHOOL December 1982 Authors: Approved by: ..... .. . . . . . . . . Thesis Advisor Second

  18. Design and Preliminary Feasibility Study of a Soft Robotic Glove for Hand Function Assistance in Stroke Survivors

    PubMed Central

    Yap, Hong Kai; Lim, Jeong Hoon; Nasrallah, Fatima; Yeow, Chen-Hua

    2017-01-01

    Various robotic exoskeletons have been proposed for hand function assistance during activities of daily living (ADL) of stroke survivors. However, traditional exoskeletons involve the use of complex rigid systems that impede the natural movement of joints, and thus reduce the wearability and cause discomfort to the user. The objective of this paper is to design and evaluate a soft robotic glove that is able to provide hand function assistance using fabric-reinforced soft pneumatic actuators. These actuators are made of silicone rubber which has an elastic modulus similar to human tissues. Thus, they are intrinsically soft and compliant. Upon air pressurization, they are able to support finger range of motion (ROM) and generate the desired actuation of the finger joints. In this work, the soft actuators were characterized in terms of their blocked tip force, normal and frictional grip force outputs. Combining the soft actuators and flexible textile materials, a soft robotic glove was developed for grasping assistance during ADL for stroke survivors. The glove was evaluated on five healthy participants for its assisted ROM and grip strength. Pilot test was performed in two stroke survivors to evaluate the efficacy of the glove in assisting functional grasping activities. Our results demonstrated that the actuators designed in this study could generate desired force output at a low air pressure. The glove had a high kinematic transparency and did not affect the active ROM of the finger joints when it was being worn by the participants. With the assistance of the glove, the participants were able to perform grasping actions with sufficient assisted ROM and grip strength, without any voluntary effort. Additionally, pilot test on stroke survivors demonstrated that the patient's grasping performance improved with the presence and assistance of the glove. Patient feedback questionnaires also showed high level of patient satisfaction and comfort. In conclusion, this paper

  19. Preduction of Vehicle Mobility on Large-Scale Soft-Soil Terrain Maps Using Physics-Based Simulation

    DTIC Science & Technology

    2016-08-02

    PREDICTION OF VEHICLE MOBILITY ON LARGE-SCALE SOFT- SOIL TERRAIN MAPS USING PHYSICS-BASED SIMULATION Tamer M. Wasfy, Paramsothy Jayakumar, Dave...NRMM • Objectives • Soft Soils • Review of Physics-Based Soil Models • MBD/DEM Modeling Formulation – Joint & Contact Constraints – DEM Cohesive... Soil Model • Cone Penetrometer Experiment • Vehicle- Soil Model • Vehicle Mobility DOE Procedure • Simulation Results • Concluding Remarks 2UNCLASSIFIED

  20. Distal chevron osteotomy with lateral soft tissue release for moderate to severe hallux valgus decided using intraoperative varus stress radiographs.

    PubMed

    Kim, Hyong-Nyun; Park, Yoo-Jung; Kim, Gab-Lae; Park, Yong-Wook

    2013-01-01

    The purpose of the present study was to investigate the outcomes of distal chevron osteotomy with lateral soft tissue release for moderate to severe hallux valgus. The patients were selected using criteria that included the degree of lateral soft tissue contracture and metatarsocuneiform joint flexibility. The contracture and flexibility were determined from intraoperative varus stress radiographs. From April 2007 to May 2009, 56 feet in 51 consecutive patients with moderate to severe hallux valgus had undergone distal chevron osteotomy with lateral soft tissue release. This was done when the lateral soft tissue contracture was not so severe that passive correction of the hallux valgus deformity was not possible and when the metatarsocuneiform joint was flexible enough to permit additional correction of the first intermetatarsal angle after lateral soft tissue release. The mean patient age was 45.2 (range 23 to 54) years, and the duration of follow-up was 27.5 (range 24 to 46) months. The mean hallux abductus angle decreased from 33.5° ± 3.1° to 11.6° ± 3.3°, and the first intermetatarsal angle decreased from 16.4° ± 2.7° to 9.7° ± 2.1°. The mean American Orthopaedic Foot and Ankle Society hallux-interphalangeal scores increased from 66.6° ± 10.7° to 92.6° ± 9.4° points, and 46 of the 51 patients (90%) were either very satisfied or satisfied with the outcome. No recurrence of deformity or osteonecrosis of the metatarsal head occurred. When lateral soft tissue contracture is not severe and when the metatarsocuneiform joint is flexible enough, distal chevron osteotomy with lateral soft tissue release can be a useful and effective choice for moderate to severe hallux valgus deformity. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Wnt10b and Dkk-1 gene therapy differentially influenced trabecular bone architecture, soft tissue integrity, and osteophytosis in a skeletally mature rat model of osteoarthritis.

    PubMed

    Mason, Jeffrey B; Gurda, Brittney L; Hankenson, Kurt D; Harper, Lindsey R; Carlson, Cathy S; Wilson, James M; Richardson, Dean W

    2017-11-01

    Our goals in the current experiments were to determine if (a) upregulation of Wnt signaling would induce osteoarthritis changes in stable stifle joints and (b) if downregulation of Wnt signaling in destabilized joints would influence the progression of OA. At 37 weeks of age, rats were injected in the stifle joint with a recombinant adeno-associated viral vector containing the Wnt-inhibitor Dkk-1 or a Wnt10b transgene. At 40 weeks of age, rats underwent surgical destabilization of the joint. At 50 weeks of age, stifle joints were submitted for micro-computed tomography and histopathological analysis. Injection of either Wnt10b or Dkk-1 transgenes in stable joints improved bone architectural parameters, but worsened soft tissue integrity. Osteophytosis was decreased by Dkk-1, but unchanged by Wnt10b. Destabilization negatively influenced bone architecture, increased osteophytosis, and decreased soft tissue integrity. Dkk-1 exacerbated the negative effects of destabilization, whereas Wnt10b had little effect on these parameters. Osteophytosis was improved, whereas soft tissue integrity was worsened by both transgenes in destabilized joints. The Wnt-inhibitor Dkk-1 does not appear to completely inhibit the effects of Wnt signaling on bone remodeling. In vivo upregulation of Wnt10b and its inhibitor, Dkk-1, can produce both parallel or contrasting phenotypic responses depending on the specific parameter measured and the fidelity of the examined joint. These observations elucidate different roles for Wnt signaling in stable versus destabilized joints and may help to explain the conflicting results previously reported for the role of Dkk-1 in joint disease.

  2. Multi-user distribution of polarization entangled photon pairs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trapateau, J.; Orieux, A.; Diamanti, E.

    We experimentally demonstrate multi-user distribution of polarization entanglement using commercial telecom wavelength division demultiplexers. The entangled photon pairs are generated from a broadband source based on spontaneous parametric down conversion in a periodically poled lithium niobate crystal using a double path setup employing a Michelson interferometer and active phase stabilisation. We test and compare demultiplexers based on various technologies and analyze the effect of their characteristics, such as losses and polarization dependence, on the quality of the distributed entanglement for three channel pairs of each demultiplexer. In all cases, we obtain a Bell inequality violation, whose value depends on themore » demultiplexer features. This demonstrates that entanglement can be distributed to at least three user pairs of a network from a single source. Additionally, we verify for the best demultiplexer that the violation is maintained when the pairs are distributed over a total channel attenuation corresponding to 20 km of optical fiber. These techniques are therefore suitable for resource-efficient practical implementations of entanglement-based quantum key distribution and other quantum communication network applications.« less

  3. A Magnetic Resonance Compatible Soft Wearable Robotic Glove for Hand Rehabilitation and Brain Imaging.

    PubMed

    Hong Kai Yap; Kamaldin, Nazir; Jeong Hoon Lim; Nasrallah, Fatima A; Goh, James Cho Hong; Chen-Hua Yeow

    2017-06-01

    In this paper, we present the design, fabrication and evaluation of a soft wearable robotic glove, which can be used with functional Magnetic Resonance imaging (fMRI) during the hand rehabilitation and task specific training. The soft wearable robotic glove, called MR-Glove, consists of two major components: a) a set of soft pneumatic actuators and b) a glove. The soft pneumatic actuators, which are made of silicone elastomers, generate bending motion and actuate finger joints upon pressurization. The device is MR-compatible as it contains no ferromagnetic materials and operates pneumatically. Our results show that the device did not cause artifacts to fMRI images during hand rehabilitation and task-specific exercises. This study demonstrated the possibility of using fMRI and MR-compatible soft wearable robotic device to study brain activities and motor performances during hand rehabilitation, and to unravel the functional effects of rehabilitation robotics on brain stimulation.

  4. Osteoarthritis of the distal interphalangeal joint.

    PubMed

    Kaufmann, Robert A; Lögters, Tim T; Verbruggen, Gust; Windolf, Joachim; Goitz, Robert J

    2010-12-01

    Osteoarthritis occurs with the highest prevalence in the distal interphalangeal joint of the hand and has been divided into an erosive and a nonerosive form. The pathogenesis of the early stages of osteoarthritis is poorly understood, but considerable emphasis has been placed on the role of cartilage and subchondral bone as well as soft tissue structures such as collateral ligaments and tendons. Radiographic evaluation represents the most standardized method to quantify disease progression, with different systems having been developed for defining and grading radiographic features. This current concepts article examines the recent knowledge base regarding the etiology, pathogenesis, and evaluation of osteoarthritis of the distal interphalangeal joint. Copyright © 2010. Published by Elsevier Inc.

  5. Softly, Softly

    ERIC Educational Resources Information Center

    Diamond, Abigail

    2008-01-01

    The term "soft skills" encompasses a cluster of personality traits, language abilities, personal habits and, ultimately, values and attitudes. Soft skills complement "harder", more technical, skills, such as being able to read or type a letter, but they also have a significant impact on the ability of people to do their jobs…

  6. Refining patterns of joint hypermobility, habitus, and orthopedic traits in joint hypermobility syndrome and Ehlers-Danlos syndrome, hypermobility type.

    PubMed

    Morlino, Silvia; Dordoni, Chiara; Sperduti, Isabella; Venturini, Marina; Celletti, Claudia; Camerota, Filippo; Colombi, Marina; Castori, Marco

    2017-04-01

    Joint hypermobility syndrome (JHS) and Ehlers-Danlos syndrome, hypermobility type (EDS-HT) are two overlapping heritable disorders (JHS/EDS-HT) recognized by separated sets of diagnostic criteria and still lack a confirmatory test. This descriptive research was aimed at better characterizing the clinical phenotype of JHS/EDS-HT with focus on available diagnostic criteria, and in order to propose novel features and assessment strategies. One hundred and eighty-nine (163 females, 26 males; age: 2-73 years) patients from two Italian reference centers were investigated for Beighton score, range of motion in 21 additional joints, rate and sites of dislocations and sprains, recurrent soft-tissue injuries, tendon and muscle ruptures, body mass index, arm span/height ratio, wrist and thumb signs, and 12 additional orthopedic features. Rough rates were compared by age, sex, and handedness with a series of parametric and non-parametric tools. Multiple correspondence analysis was carried out for possible co-segregations of features. Beighton score and hypermobility at other joints were influenced by age at diagnosis. Rate and sites of joint instability complications did not vary according to age at diagnosis except for soft-tissue injuries. No major difference was registered by sex and dominant versus non-dominant body side. At multiple correspondence analysis, selected features tend to co-segregate in a dichotomous distribution. Dolichostenomelia and arachnodactyly segregated independently. This study pointed out a more protean musculoskeletal phenotype than previously considered according to available diagnostic criteria for JHS/EDS-HT. Our findings corroborated the need for a re-thinking of JHS/EDS-HT on clinical grounds in order to find better therapeutic and research strategies. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. A hard X-ray view of the soft excess in AGN

    NASA Astrophysics Data System (ADS)

    Boissay, R.; Ricci, C.; Paltani, S.

    2017-10-01

    A soft X-ray emission in excess of the extrapolation of the hard X-ray continuum is detected in many Seyfert 1 galaxies below 1 keV. To understand the uncertain nature of this soft excess, which could be due to warm Comptonization or to blurred ionized reflection, we consider the different behaviors of these models above 10 keV. We present the results of a study done on 102 Seyfert 1s from the Swift BAT 70-Month Hard X-ray Survey catalog. We have performed the joint spectral analysis of Swift/BAT and XMM-Newton data in order to get a hard X-ray view of the soft excess. We discuss the links between the soft-excess strength and the reflection at high energy, the slope of the continuum and the Eddington ratio. We compare our results to simulations of blurred ionized-reflection models and show that they are in contradiction. Indeed, we do not find the expected correlation between the reflection and the soft-excess strengths, neither in individual, nor in stacked spectra. We also present our current project of broadband fitting, using different models explaining the soft excess, to simultaneous XMM-Newton and NuSTAR observations of about ten objects of our sample.

  8. Photoacoustic and ultrasound dual-modality imaging of human peripheral joints

    NASA Astrophysics Data System (ADS)

    Xu, Guan; Rajian, Justin R.; Girish, Gandikota; Kaplan, Mariana J.; Fowlkes, J. Brian; Carson, Paul L.; Wang, Xueding

    2013-01-01

    A photoacoustic (PA) and ultrasound (US) dual modality system, for imaging human peripheral joints, is introduced. The system utilizes a commercial US unit for both US control imaging and PA signal acquisition. Preliminary in vivo evaluation of the system, on normal volunteers, revealed that this system can recover both the structural and functional information of intra- and extra-articular tissues. Confirmed by the control US images, the system, on the PA mode, can differentiate tendon from surrounding soft tissue based on the endogenous optical contrast. Presenting both morphological and pathological information in joint, this system holds promise for diagnosis and characterization of inflammatory joint diseases such as rheumatoid arthritis.

  9. [Arthroscopy-guided fracture management. Ankle joint and calcaneus].

    PubMed

    Schoepp, C; Rixen, D

    2013-04-01

    Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.

  10. Soft translations and soft extensions of BCI/BCK-algebras.

    PubMed

    Sultana, Nazra; Rani, Nazia; Ali, Muhammad Irfan; Hussain, Azhar

    2014-01-01

    The concept of soft translations of soft subalgebras and soft ideals over BCI/BCK-algebras is introduced and some related properties are studied. Notions of Soft extensions of soft subalgebras and soft ideals over BCI/BCK-algebras are also initiated. Relationships between soft translations and soft extensions are explored.

  11. Exploring the Educational Potential of Three-Dimensional Multi-User Virtual Worlds for STEM Education: A Mixed-Method Systematic Literature Review

    ERIC Educational Resources Information Center

    Pellas, Nikolaos; Kazanidis, Ioannis; Konstantinou, Nikolaos; Georgiou, Georgia

    2017-01-01

    The present literature review builds on the results of 50 research articles published from 2000 until 2016. All these studies have successfully accomplished various learning tasks in the domain of Science, Technology, Engineering, and Mathematics (STEM) education using three-dimensional (3-D) multi-user virtual worlds for Primary, Secondary and…

  12. Soft Translations and Soft Extensions of BCI/BCK-Algebras

    PubMed Central

    Sultana, Nazra; Rani, Nazia; Ali, Muhammad Irfan

    2014-01-01

    The concept of soft translations of soft subalgebras and soft ideals over BCI/BCK-algebras is introduced and some related properties are studied. Notions of Soft extensions of soft subalgebras and soft ideals over BCI/BCK-algebras are also initiated. Relationships between soft translations and soft extensions are explored. PMID:25298968

  13. Blind information-theoretic multiuser detection algorithms for DS-CDMA and WCDMA downlink systems.

    PubMed

    Waheed, Khuram; Salem, Fathi M

    2005-07-01

    Code division multiple access (CDMA) is based on the spread-spectrum technology and is a dominant air interface for 2.5G, 3G, and future wireless networks. For the CDMA downlink, the transmitted CDMA signals from the base station (BS) propagate through a noisy multipath fading communication channel before arriving at the receiver of the user equipment/mobile station (UE/MS). Classical CDMA single-user detection (SUD) algorithms implemented in the UE/MS receiver do not provide the required performance for modern high data-rate applications. In contrast, multi-user detection (MUD) approaches require a lot of a priori information not available to the UE/MS. In this paper, three promising adaptive Riemannian contra-variant (or natural) gradient based user detection approaches, capable of handling the highly dynamic wireless environments, are proposed. The first approach, blind multiuser detection (BMUD), is the process of simultaneously estimating multiple symbol sequences associated with all the users in the downlink of a CDMA communication system using only the received wireless data and without any knowledge of the user spreading codes. This approach is applicable to CDMA systems with relatively short spreading codes but becomes impractical for systems using long spreading codes. We also propose two other adaptive approaches, namely, RAKE -blind source recovery (RAKE-BSR) and RAKE-principal component analysis (RAKE-PCA) that fuse an adaptive stage into a standard RAKE receiver. This adaptation results in robust user detection algorithms with performance exceeding the linear minimum mean squared error (LMMSE) detectors for both Direct Sequence CDMA (DS-CDMA) and wide-band CDMA (WCDMA) systems under conditions of congestion, imprecise channel estimation and unmodeled multiple access interference (MAI).

  14. Soft tissue-based surgical techniques for treatment of posterior shoulder instability.

    PubMed

    Castagna, Alessandro; Conti, Marco; Garofalo, Raffaele

    2017-01-01

    Posterior shoulder instability is a rare clinical condition that encompasses different degrees of severity including various possible pathologies involving the labrum, capsule, bony lesions, and even locked posterior dislocation. When focusing on soft tissue involvement, the diagnosis of posterior instability may be difficult to make because frequently patients report vague symptoms not associated with a clear history of traumatic shoulder dislocation. Pathological soft tissue conditions associated with posterior instability in most cases are related to posterior labral tear and/or posterior capsular detensioning/tear. The diagnosis can be facilitated by physical examination using specific clinical tests (i. e., jerk test, Kim test, and reinterpreted O'Brien test) together with appropriate imaging studies (i. e., magnetic resonance arthrography). Arthroscopy may help in a complete evaluation of the joint and allows for the treatment of soft tissue lesions in posterior instability. Caution is warranted in the case of concomitant posterior glenoid chondral defect as a potential cause of poor outcome after soft tissue repair in posterior instability.

  15. Multi-User Spaceport Update News Conference

    NASA Image and Video Library

    2014-01-23

    CAPE CANAVERAL, Fla. – Sierra Nevada Corporation, or SNC, Space Systems, announces the steps the company will take to prepare for a November 2016 orbital flight of its Dream Chaser spacecraft from Florida’s Space Coast during a news conference at NASA’s Kennedy Space Center in Florida. Participants are, from left, Michael Curie, NASA spokesman, Bob Cabana, director of Kennedy, Michael Gass, president and CEO of United Launch Alliance, or ULA, Frank DiBello, president and CEO of Space Florida, Mark Sirangelo, corporate vice president and head of SNC Space Systems, Larry Price, Lockheed Martin Space Systems deputy program manager for NASA's Orion spacecraft, and Steve Lindsey, Dream Chaser program manager for SNC Space Systems. The steps are considered substantial for SNC and important to plans by NASA and Space Florida for Kennedy’s transformation into a multi-user spaceport for both commercial and government customers. SNC said it plans to work with ULA to launch the Dream Chaser spacecraft into orbit atop an Atlas V rocket from Space Launch Complex 41 at Cape Canaveral Air Force Station intends to land the winged spacecraft at Kennedy’s 3.5-mile long runway at the Shuttle Landing Facility lease office space at Exploration Park, right outside Kennedy’s gates and process the spacecraft in the high bay of the Operations and Checkout Building at Kennedy, with Lockheed Martin performing the work. Photo credit: NASA/Kim Shiflett

  16. Performance of single-use and multiuse diamond rotary cutting instruments with turbine and electric handpieces.

    PubMed

    Rotella, Mario; Ercoli, Carlo; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong

    2014-01-01

    As single-use rotary cutting instruments and electric handpieces become more available, the performance of these instruments with electric as compared to turbine handpieces requires evaluation. In addition, if rotary cutting instruments marketed as single-use instruments are used for multiple patients, the effects on their performance of cleaning, sterilization, and repeated use are of interest to the clinician. The purpose of the study was to evaluate how the cleaning, autoclaving, and repeated use of single-use and multiuse rotary cutting instruments, with either a turbine or electric handpiece, affected their performance. The effects on cutting performance of 2 handpieces (turbine and electric), 2 cleaning and sterilization conditions (cleaned and autoclaved versus noncleaned and nonautoclaved), and 6 different diamond rotary cutting instruments (4 single-use and 2 multiuse) during simulated tooth preparations were evaluated by using a 24-treatment condition full-factorial experimental design. A computer-controlled dedicated testing apparatus was used to simulate the cutting procedures, and machinable glass ceramic blocks were used as the cutting substrate for tangential cuts. In addition, for each treatment condition, 8 consecutive cuts, for a total of 192 cuts, were measured to assess the durability of the rotary cutting instruments. A linear mixed model was used to study the effect of instrument type, handpiece, cleaning, and sterilization, as well as the status and number of cuts on the outcome variables. The Tukey honestly significant difference test was used for the post hoc pairwise comparisons (α=.05). Performance, as measured by the rate of advancement, decreased with the repeated use of rotary cutting instruments (P<.001), while cleaning and sterilization procedures improved the average performance of the 8 cuts (P=.002). The electric handpiece showed a greater load than the turbine (P<.001) and a lower rate/load metric, but no differences in the rate

  17. Knee Kinematics Estimation Using Multi-Body Optimisation Embedding a Knee Joint Stiffness Matrix: A Feasibility Study.

    PubMed

    Richard, Vincent; Lamberto, Giuliano; Lu, Tung-Wu; Cappozzo, Aurelio; Dumas, Raphaël

    2016-01-01

    The use of multi-body optimisation (MBO) to estimate joint kinematics from stereophotogrammetric data while compensating for soft tissue artefact is still open to debate. Presently used joint models embedded in MBO, such as mechanical linkages, constitute a considerable simplification of joint function, preventing a detailed understanding of it. The present study proposes a knee joint model where femur and tibia are represented as rigid bodies connected through an elastic element the behaviour of which is described by a single stiffness matrix. The deformation energy, computed from the stiffness matrix and joint angles and displacements, is minimised within the MBO. Implemented as a "soft" constraint using a penalty-based method, this elastic joint description challenges the strictness of "hard" constraints. In this study, estimates of knee kinematics obtained using MBO embedding four different knee joint models (i.e., no constraints, spherical joint, parallel mechanism, and elastic joint) were compared against reference kinematics measured using bi-planar fluoroscopy on two healthy subjects ascending stairs. Bland-Altman analysis and sensitivity analysis investigating the influence of variations in the stiffness matrix terms on the estimated kinematics substantiate the conclusions. The difference between the reference knee joint angles and displacements and the corresponding estimates obtained using MBO embedding the stiffness matrix showed an average bias and standard deviation for kinematics of 0.9±3.2° and 1.6±2.3 mm. These values were lower than when no joint constraints (1.1±3.8°, 2.4±4.1 mm) or a parallel mechanism (7.7±3.6°, 1.6±1.7 mm) were used and were comparable to the values obtained with a spherical joint (1.0±3.2°, 1.3±1.9 mm). The study demonstrated the feasibility of substituting an elastic joint for more classic joint constraints in MBO.

  18. The Impact of Student Self-Efficacy on Scientific Inquiry Skills: An Exploratory Investigation in "River City," a Multi-User Virtual Environment

    ERIC Educational Resources Information Center

    Ketelhut, Diane Jass

    2007-01-01

    This exploratory study investigated data-gathering behaviors exhibited by 100 seventh-grade students as they participated in a scientific inquiry-based curriculum project delivered by a multi-user virtual environment (MUVE). This research examined the relationship between students' self-efficacy on entry into the authentic scientific activity and…

  19. Design, characterisation and evaluation of a soft robotic sock device on healthy subjects for assisted ankle rehabilitation.

    PubMed

    Low, Fan-Zhe; Lim, Jeong Hoon; Yeow, Chen-Hua

    2018-01-01

    Motor impairment is one of the common neurological conditions suffered by stroke patients, where this chronic immobility together with the absence of early limb mobilisation can lead to conditions such as joint contracture with spastic limbs. In this study, a soft robotic sock device was developed, which can provide compliant actuation to the ankle joint in the early stage of stroke recovery. The device is fitted with soft extension actuators and when the actuators are inflated, they extend and guide the foot into plantarflexion; upon deflation, the actuators will resume their initial conformations. Each actuator is linked to a pneumatic pump-valve control system that injects pressurised air into or release air from the system. In this study, the design and characterisation of the soft actuators will be presented, where the theoretical and experimental forces generated by the actuators were compared. The performance of the device was also evaluated on healthy subjects and the results had shown that the device was able to move the subjects' ankles into cycles of dorsiflexion-plantarflexion, in the absence of voluntary muscle effort. The findings suggested that the soft wearable robotic device was capable of assisting the subjects in performing repeated cycles of ankle flexion.

  20. Cross-view gait recognition using joint Bayesian

    NASA Astrophysics Data System (ADS)

    Li, Chao; Sun, Shouqian; Chen, Xiaoyu; Min, Xin

    2017-07-01

    Human gait, as a soft biometric, helps to recognize people by walking. To further improve the recognition performance under cross-view condition, we propose Joint Bayesian to model the view variance. We evaluated our prosed method with the largest population (OULP) dataset which makes our result reliable in a statically way. As a result, we confirmed our proposed method significantly outperformed state-of-the-art approaches for both identification and verification tasks. Finally, sensitivity analysis on the number of training subjects was conducted, we find Joint Bayesian could achieve competitive results even with a small subset of training subjects (100 subjects). For further comparison, experimental results, learning models, and test codes are available.

  1. [Generalised Form of Synovial Chondromatosis of the Knee Joint].

    PubMed

    Vališ, P; Vyskočil, R

    2016-01-01

    This study describes a diagnostic and therapeutic algorithm in a 53-year-old male patient who was diagnosed with a synovial chondromatosis of the knee joint extending to the popliteal fossa and soft tissues around the knee. Because of the presence of massive nodules, the patient was indicated for total synovectomy, with removal of pathologically changed cartilaginous tissue, performed by combined anterior and posterior approaches to the knee joint. Despite complete removal of the synovium and loose cartilage bodies and the patient's pain relief in the post-operative time, three years after the operation new problems appeared. Magnetic resonance imaging (MRI) confirmed a relapse of synovial chondromatosis and the patient was indicated for revision surgery of the knee joint. The results of physical examination and MRI scans, and intra-operative findings in the patient are reported. synovial chondromatosis, total synovectomy, direct anterior and posterior approaches to the knee joint.

  2. Design and Validation of Exoskeleton Actuated by Soft Modules toward Neurorehabilitation-Vision-Based Control for Precise Reaching Motion of Upper Limb.

    PubMed

    Oguntosin, Victoria W; Mori, Yoshiki; Kim, Hyejong; Nasuto, Slawomir J; Kawamura, Sadao; Hayashi, Yoshikatsu

    2017-01-01

    We demonstrated the design, production, and functional properties of the Exoskeleton Actuated by the Soft Modules (EAsoftM). Integrating the 3D printed exoskeleton with passive joints to compensate gravity and with active joints to rotate the shoulder and elbow joints resulted in ultra-light system that could assist planar reaching motion by using the vision-based control law. The EAsoftM can support the reaching motion with compliance realized by the soft materials and pneumatic actuation. In addition, the vision-based control law has been proposed for the precise control over the target reaching motion within the millimeter scale. Aiming at rehabilitation exercise for individuals, typically soft actuators have been developed for relatively small motions, such as grasping motion, and one of the challenges has been to extend their use for a wider range reaching motion. The proposed EAsoftM presented one possible solution for this challenge by transmitting the torque effectively along the anatomically aligned with a human body exoskeleton. The proposed integrated systems will be an ideal solution for neurorehabilitation where affordable, wearable, and portable systems are required to be customized for individuals with specific motor impairments.

  3. Design and Validation of Exoskeleton Actuated by Soft Modules toward Neurorehabilitation—Vision-Based Control for Precise Reaching Motion of Upper Limb

    PubMed Central

    Oguntosin, Victoria W.; Mori, Yoshiki; Kim, Hyejong; Nasuto, Slawomir J.; Kawamura, Sadao; Hayashi, Yoshikatsu

    2017-01-01

    We demonstrated the design, production, and functional properties of the Exoskeleton Actuated by the Soft Modules (EAsoftM). Integrating the 3D printed exoskeleton with passive joints to compensate gravity and with active joints to rotate the shoulder and elbow joints resulted in ultra-light system that could assist planar reaching motion by using the vision-based control law. The EAsoftM can support the reaching motion with compliance realized by the soft materials and pneumatic actuation. In addition, the vision-based control law has been proposed for the precise control over the target reaching motion within the millimeter scale. Aiming at rehabilitation exercise for individuals, typically soft actuators have been developed for relatively small motions, such as grasping motion, and one of the challenges has been to extend their use for a wider range reaching motion. The proposed EAsoftM presented one possible solution for this challenge by transmitting the torque effectively along the anatomically aligned with a human body exoskeleton. The proposed integrated systems will be an ideal solution for neurorehabilitation where affordable, wearable, and portable systems are required to be customized for individuals with specific motor impairments. PMID:28736514

  4. Effects of Spearfishing on Reef Fish Populations in a Multi-Use Conservation Area

    PubMed Central

    Frisch, Ashley J.; Cole, Andrew J.; Hobbs, Jean-Paul A.; Rizzari, Justin R.; Munkres, Katherine P.

    2012-01-01

    Although spearfishing is a popular method of capturing fish, its ecological effects on fish populations are poorly understood, which makes it difficult to assess the legitimacy and desirability of spearfishing in multi-use marine reserves. Recent management changes within the Great Barrier Reef Marine Park (GBRMP) fortuitously created a unique scenario by which to quantify the effects of spearfishing on fish populations. As such, we employed underwater visual surveys and a before-after-control-impact experimental design to investigate the effects of spearfishing on the density and size structure of target and non-target fishes in a multi-use conservation park zone (CPZ) within the GBRMP. Three years after spearfishing was first allowed in the CPZ, there was a 54% reduction in density and a 27% reduction in mean size of coral trout (Plectropomus spp.), the primary target species. These changes were attributed to spearfishing because benthic habitat characteristics and the density of non-target fishes were stable through time, and the density and mean size of coral trout in a nearby control zone (where spearfishing was prohibited) remained unchanged. We conclude that spearfishing, like other forms of fishing, can have rapid and substantial negative effects on target fish populations. Careful management of spearfishing is therefore needed to ensure that conservation obligations are achieved and that fishery resources are harvested sustainably. This is particularly important both for the GBRMP, due to its extraordinarily high conservation value and world heritage status, and for tropical island nations where people depend on spearfishing for food and income. To minimize the effects of spearfishing on target species and to enhance protection of functionally important fishes (herbivores), we recommend that fishery managers adjust output controls such as size- and catch-limits, rather than prohibit spearfishing altogether. This will preserve the cultural and social

  5. Further Results of Soft-Inplane Tiltrotor Aeromechanics Investigation Using Two Multibody Analyses

    NASA Technical Reports Server (NTRS)

    Masarati, Pierangelo; Quaranta, Giuseppe; Piatak, David J.; Singleton, Jeffrey D.

    2004-01-01

    This investigation focuses on the development of multibody analytical models to predict the dynamic response, aeroelastic stability, and blade loading of a soft-inplane tiltrotor wind-tunnel model. Comprehensive rotorcraft-based multibody analyses enable modeling of the rotor system to a high level of detail such that complex mechanics and nonlinear effects associated with control system geometry and joint deadband may be considered. The influence of these and other nonlinear effects on the aeromechanical behavior of the tiltrotor model are examined. A parametric study of the design parameters which may have influence on the aeromechanics of the soft-inplane rotor system are also included in this investigation.

  6. Soft-information flipping approach in multi-head multi-track BPMR systems

    NASA Astrophysics Data System (ADS)

    Warisarn, C.; Busyatras, W.; Myint, L. M. M.

    2018-05-01

    Inter-track interference is one of the most severe impairments in bit-patterned media recording system. This impairment can be effectively handled by a modulation code and a multi-head array jointly processing multiple tracks; however, such a modulation constraint has never been utilized to improve the soft-information. Therefore, this paper proposes the utilization of modulation codes with an encoded constraint defined by the criteria for soft-information flipping during a three-track data detection process. Moreover, we also investigate the optimal offset position of readheads to provide the most improvement in system performance. The simulation results indicate that the proposed systems with and without position jitter are significantly superior to uncoded systems.

  7. Multiscale biomechanical responses of adapted bone-periodontal ligament-tooth fibrous joints

    PubMed Central

    Jang, Andrew T.; Merkle, Arno; Fahey, Kevin; Gansky, Stuart A.; Ho, Sunita P.

    2015-01-01

    Reduced functional loads cause adaptations in organs. In this study, temporal adaptations of bone-ligament-tooth fibrous joints to reduced functional loads were mapped using a holistic approach. Systematic studies were performed to evaluate organ-level and tissue-level adaptations in specimens harvested periodically from rats given powder food for 6 months (N = 60 over 8,12,16,20, and 24 weeks). Bone-periodontal ligament (PDL)-tooth fibrous joint adaptation was evaluated by comparing changes in joint stiffness with changes in functional space between the tooth and alveolar bony socket. Adaptations in tissues included mapping changes in the PDL and bone architecture as observed from collagen birefringence, bone hardness and volume fraction in rats fed soft foods (soft diet, SD) compared to those fed hard pellets as a routine diet (hard diet, HD). In situ biomechanical testing on harvested fibrous joints revealed increased stiffness in SD groups (SD:239-605 N/mm) (p<0.05) at 8 and 12 weeks. Increased joint stiffness in early development phase was due to decreased functional space (at 8wks change in functional space was −33 µm, at 12wks change in functional space was −30 µm) and shifts in tissue quality as highlighted by birefringence, architecture and hardness. These physical changes were not observed in joints that were well into function, that is, in rodents older than 12 weeks of age. Significant adaptations in older groups were highlighted by shifts in bone growth (bone volume fraction 24wks: Δ-0.06) and bone hardness (8wks: Δ−0.04 GPa, 16 wks: Δ−0.07 GPa, 24wks: Δ−0.06 GPa). The response rate (N/s) of joints to mechanical loads decreased in SD groups. Results from the study showed that joint adaptation depended on age. The initial form-related adaptation (observed change in functional space) can challenge strain-adaptive nature of tissues to meet functional demands with increasing age into adulthood. The coupled effect between functional space in

  8. A nondestructive, reproducible method of measuring joint reaction force at the distal radioulnar joint.

    PubMed

    Canham, Colin D; Schreck, Michael J; Maqsoodi, Noorullah; Doolittle, Madison; Olles, Mark; Elfar, John C

    2015-06-01

    To develop a nondestructive method of measuring distal radioulnar joint (DRUJ) joint reaction force (JRF) that preserves all periarticular soft tissues and more accurately reflects in vivo conditions. Eight fresh-frozen human cadaveric limbs were obtained. A threaded Steinmann pin was placed in the middle of the lateral side of the distal radius transverse to the DRUJ. A second pin was placed into the middle of the medial side of the distal ulna colinear to the distal radial pin. Specimens were mounted onto a tensile testing machine using a custom fixture. A uniaxial distracting force was applied across the DRUJ while force and displacement were simultaneously measured. Force-displacement curves were generated and a best-fit polynomial was solved to determine JRF. All force-displacement curves demonstrated an initial high slope where relatively large forces were required to distract the joint. This ended with an inflection point followed by a linear area with a low slope, where small increases in force generated larger amounts of distraction. Each sample was measured 3 times and there was high reproducibility between repeated measurements. The average baseline DRUJ JRF was 7.5 N (n = 8). This study describes a reproducible method of measuring DRUJ reaction forces that preserves all periarticular stabilizing structures. This technique of JRF measurement may also be suited for applications in the small joints of the wrist and hand. Changes in JRF can alter native joint mechanics and lead to pathology. Reliable methods of measuring these forces are important for determining how pathology and surgical interventions affect joint biomechanics. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko

    2012-06-01

    Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Localized cervical facet joint kinematics under physiological and whiplash loading.

    PubMed

    Stemper, Brian D; Yoganandan, Narayan; Gennarelli, Thomas A; Pintar, Frank A

    2005-12-01

    Although facet joints have been implicated in the whiplash injury mechanism, no investigators have determined the degree to which joint motions in whiplash are nonphysiological. The purpose of this investigation was to quantify the correlation between facet joint and segmental motions under physiological and whiplash loading. Human cadaveric cervical spine specimens were exercise tested under physiological extension loading, and intact human head-neck complexes were exercise tested under whiplash loading to correlate the localized component motions of the C4-5 facet joint with segmental extension. Facet joint shear and distraction kinematics demonstrated a linear correlation with segmental extension under both loading modes. Facet joints responded differently to whiplash and physiological loading, with significantly increased kinematics for the same-segmental angulation. The limitations of this study include removal of superficial musculature and the limited sample size for physiological testing. The presence of increased facet joint motions indicated that synovial joint soft-tissue components (that is, synovial membrane and capsular ligament) sustain increased distortion that may subject these tissues to a greater likelihood of injury. This finding is supported by clinical investigations in which lower cervical facet joint injury resulted in similar pain patterns due to the most commonly reported whiplash symptoms.

  11. Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-11-01

    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

  12. Improving Kinematic Accuracy of Soft Wearable Data Gloves by Optimizing Sensor Locations

    PubMed Central

    Kim, Dong Hyun; Lee, Sang Wook; Park, Hyung-Soon

    2016-01-01

    Bending sensors enable compact, wearable designs when used for measuring hand configurations in data gloves. While existing data gloves can accurately measure angular displacement of the finger and distal thumb joints, accurate measurement of thumb carpometacarpal (CMC) joint movements remains challenging due to crosstalk between the multi-sensor outputs required to measure the degrees of freedom (DOF). To properly measure CMC-joint configurations, sensor locations that minimize sensor crosstalk must be identified. This paper presents a novel approach to identifying optimal sensor locations. Three-dimensional hand surface data from ten subjects was collected in multiple thumb postures with varied CMC-joint flexion and abduction angles. For each posture, scanned CMC-joint contours were used to estimate CMC-joint flexion and abduction angles by varying the positions and orientations of two bending sensors. Optimal sensor locations were estimated by the least squares method, which minimized the difference between the true CMC-joint angles and the joint angle estimates. Finally, the resultant optimal sensor locations were experimentally validated. Placing sensors at the optimal locations, CMC-joint angle measurement accuracies improved (flexion, 2.8° ± 1.9°; abduction, 1.9° ± 1.2°). The proposed method for improving the accuracy of the sensing system can be extended to other types of soft wearable measurement devices. PMID:27240364

  13. Soft Ultrathin Electronics Innervated Adaptive Fully Soft Robots.

    PubMed

    Wang, Chengjun; Sim, Kyoseung; Chen, Jin; Kim, Hojin; Rao, Zhoulyu; Li, Yuhang; Chen, Weiqiu; Song, Jizhou; Verduzco, Rafael; Yu, Cunjiang

    2018-03-01

    Soft robots outperform the conventional hard robots on significantly enhanced safety, adaptability, and complex motions. The development of fully soft robots, especially fully from smart soft materials to mimic soft animals, is still nascent. In addition, to date, existing soft robots cannot adapt themselves to the surrounding environment, i.e., sensing and adaptive motion or response, like animals. Here, compliant ultrathin sensing and actuating electronics innervated fully soft robots that can sense the environment and perform soft bodied crawling adaptively, mimicking an inchworm, are reported. The soft robots are constructed with actuators of open-mesh shaped ultrathin deformable heaters, sensors of single-crystal Si optoelectronic photodetectors, and thermally responsive artificial muscle of carbon-black-doped liquid-crystal elastomer (LCE-CB) nanocomposite. The results demonstrate that adaptive crawling locomotion can be realized through the conjugation of sensing and actuation, where the sensors sense the environment and actuators respond correspondingly to control the locomotion autonomously through regulating the deformation of LCE-CB bimorphs and the locomotion of the robots. The strategy of innervating soft sensing and actuating electronics with artificial muscles paves the way for the development of smart autonomous soft robots. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Comparison of distal chevron osteotomy with and without lateral soft tissue release for the treatment of hallux valgus.

    PubMed

    Lee, Ho-Jin; Chung, Jin-Wha; Chu, In-Tak; Kim, Yoon-Chung

    2010-04-01

    A lateral soft tissue release is often performed with distal chevron osteotomy for the correction of hallux valgus deformities. However, many complications of lateral soft tissue release have been reported. To define the necessity of lateral soft tissue release, the authors compared the clinical and radiographic results of distal chevron osteotomy with and without it. 86 consecutive patients (152 feet) were enrolled in this prospective study. In Group A, 45 patients (74 feet) underwent a chevron osteotomy with lateral soft tissue release. In Group B, 41 patients (78 feet) underwent a chevron osteotomy without it. Mean followup was 1.7 years and 2.1 years, respectively. The hallux valgus angle (HVA) and intermetatarsal angle (IMA), and AOFAS score were measured preoperatively, and 1-year followup postoperatively and complications were evaluated. The change in HVA, IMA and AOFAS score were insignificant (p > 0.05) between Group A and Group B, however, the range of motion of the first metatarsophalangeal joint was significantly less in Group A (p < 0.05). Complications of digital neuritis and cosmetically dissatisfied scarring of the dorsal web space were seen only in Group A. No cases had avascular necrosis of the metatarsal head, malunion or nonunion. Lateral soft tissue release may not be needed for mild or moderate hallux valgus deformities which may prevent decreased range of motion of the first metatarsophalangeal joint, neuritis of dorsal or plantar lateral digital nerve and cosmetic dissatisfaction of a dorsal scar.

  15. Neoadjuvant chemotherapy in soft tissue sarcomas: latest evidence and clinical implications

    PubMed Central

    Pasquali, Sandro; Gronchi, Alessandro

    2017-01-01

    Soft tissue sarcomas are a rare and multifaceted group of solid tumours. Neoadjuvant chemotherapy is increasingly used to limit loss of function after wide surgical excision with the ultimate aim of improving patient survival. Recently, advances in the identification of effective treatment strategies and improvements in patient risk stratification have been reached. A randomized trial demonstrated that neoadjuvant epirubicin and ifosfamide improves survival of patients affected by five high-risk soft tissue sarcoma histologies of trunk and extremities, including undifferentiated pleomorphic sarcoma, myxoid liposarcoma, synovial sarcoma, malignant peripheral nerve sheath tumours, and leiomyosarcoma. Selection of patients for these treatments is expected to be improved by the eighth edition of the American Joint Committee on Cancer (AJCC) TNM staging system, as it tailors T-stage categories on primary tumour site and considers a prognostic nomogram for retroperitoneal sarcoma, which also includes soft tissue sarcoma histology and other patient and tumour features not directly included in the TNM staging. Within this framework, this article will present neoadjuvant treatment strategies for high-risk soft tissue sarcoma, emphasizing the most recent advances and discussing the need for further research to improve the effectiveness of neoadjuvant treatments. PMID:28607580

  16. The efficacy of instrument assisted soft tissue mobilization: a systematic review.

    PubMed

    Cheatham, Scott W; Lee, Matt; Cain, Matt; Baker, Russell

    2016-09-01

    Instrument assisted soft tissue mobilization (IASTM) is a popular treatment for myofascial restriction. IASTM uses specially designed instruments to provide a mobilizing effect to scar tissue and myofascial adhesions. Several IASTM tools and techniques are available such as the Graston® technique. Currently, there are no systematic reviews that have specifically appraised the effects of IASTM as a treatment or to enhance joint range of motion (ROM). The purpose of this study was to systematically appraise the current evidence assessing the effects of IASTM as an intervention to treat a musculoskeletal pathology or to enhance joint ROM. A search of the literature was conducted during the month of December 2015 which included the following databases: PubMed, PEDro, Science Direct, and the EBSCOhost collection. A direct search of known journals was also conducted to identify potential publications. The search terms included individual or a combination of the following: instrument; assisted; augmented; soft-tissue; mobilization; Graston®; and technique. A total of 7 randomized controlled trials were appraised. Five of the studies measured an IASTM intervention versus a control or alternate intervention group for a musculoskeletal pathology. The results of the studies were insignificant (p>.05) with both groups displaying equal outcomes. Two studies measured an IASTM intervention versus a control or alternate intervention group on the effects of joint ROM. The IASTM intervention produced significant (P<.05) short term gains up to 24 hours. The literature measuring the effects of IASTM is still emerging. The current research has indicated insignificant results which challenges the efficacy of IASTM as a treatment for common musculoskeletal pathology, which may be due to the methodological variability among studies. There appears to be some evidence supporting its ability to increase short term joint ROM.

  17. MRI-based stereolithographic models of the temporomandibular joint: technical innovation.

    PubMed

    Undt, G; Wild, K; Reuther, G; Ewers, R

    2000-10-01

    A new technique of manufacturing dual-colour stereolithographic models of hard and soft tissues of the temporomandibular joint (TMJ) is presented. Sagittal T1/PD weighted magnetic resonance (MR) images of joints with and without disc displacement were obtained in the closed and open mouth positions. Individual interactive contour identification of bony structures and the articular disc followed by binary interpolation provided the data for the generation of acrylic TMJ models. Three dimensional in vivo visualization of the articular disc in relation to bony structures in the closed and open mouth positions allows a new perception of normal and pathological TMJ anatomy.

  18. Atmospheric lidar multi-user instrument system definition study

    NASA Technical Reports Server (NTRS)

    Greco, R. V. (Editor)

    1980-01-01

    A spaceborne lidar system for atmospheric studies was defined. The primary input was the Science Objectives Experiment Description and Evolutionary Flow Document. The first task of the study was to perform an experiment evolutionary analysis of the SEED. The second task was the system definition effort of the instrument system. The third task was the generation of a program plan for the hardware phase. The fourth task was the supporting studies which included a Shuttle deficiency analysis, a preliminary safety hazard analysis, the identification of long lead items, and development studies required. As a result of the study an evolutionary Lidar Multi-User Instrument System (MUIS) was defined. The MUIS occupies a full Spacelab pallet and has a weight of 1300 kg. The Lidar MUIS laser provides a 2 joule frequency doubled Nd:YAG laser that can also pump a tuneable dye laser wide frequency range and bandwidth. The MUIS includes a 1.25 meter diameter aperture Cassegrain receiver, with a moveable secondary mirror to provide precise alignment with the laser. The receiver can transmit the return signal to three single and multiple photomultiple tube detectors by use of a rotating fold mirror. It is concluded that the Lidar MUIS proceed to program implementation.

  19. [Reconstruction and balance of soft tissue in hemi-shoulder replacement for patients with four-part fracture of the proximal humerus].

    PubMed

    Wu, Xing; Lou, Lie-ming; Chen, Zheng-rong; Zhang, Guang-jian

    2008-10-01

    To explore the effective skills of reconstruction and balance of soft tissue in hemi-shoulder replacement for patients with four-part fracture of the proximal humerus in order to avoid postoperative complications of joint instability and great tubercle displacement. From June 2002 to June 2006, 25 patients with Neer four-part fracture of the proximal humerus were adopted in the study which included 15 females and 10 males, with the mean age of 66 years (ranged from 56 years to 80 years). They were treated with humeral head replacement and should joint reparation simultaneously by modified operation approach and reconstruction and balance skills of soft tissue. The mean duration of follow-up was 2.3 years (ranged from 1 to 4.5 years). No infection, nerve damage and prosthesis loosing were found in all cases. Two cases of infra-forward dislocation or subluxation occurred due to affected limb placed on abduction splint postoperatively. One case occurred prosthesis upward displacement due to early active abduction exercise but no complains. Neither joint instability nor displacement and malunion of great tubercle were found in other patients. According to Neer scoring system, 6 cases were rated as excellent, 15 as good and 5 as fair. The good and excellent rate was 84%. In hemi-shoulder replacement for patients with Neer four-part fracture the modified operation approach and reconstruction and balance of soft tissue skills combined with rational rehabilitation exercise can prevent postoperative shoulder joint instability and displacement and malunion of great tubercle.

  20. Synovial haemangioma of the knee joint: an unusual cause of knee pain in a 14-month old girl.

    PubMed

    Wen, D W; Tan, T J; Rasheed, S

    2016-06-01

    We report a histologically proven case of synovial haemangioma of the knee in a 14-month old girl who presented to the emergency department with an acute 1-day history of refusing to weight-bear on the right leg and a preceding 3-week history of a right knee lump. Physical examination revealed a non-tender, soft lump over the lateral infrapatellar region. Radiographs revealed a poorly defined soft tissue density over the infrapatellar fat pad and a suprapatellar joint effusion. Ultrasound was used to confirm the presence of a vascular soft tissue mass compatible with a synovial haemangioma within the infrapatellar fat pad which showed both intra-articular and extra-articular extension. There was good correlation of the ultrasound findings with magnetic resonance imaging (MRI), highlighting the potential clinical utility of ultrasound as an alternative imaging modality in establishing the pre-operative diagnosis and extent of a synovial haemangioma about the knee joint.

  1. Marky: a tool supporting annotation consistency in multi-user and iterative document annotation projects.

    PubMed

    Pérez-Pérez, Martín; Glez-Peña, Daniel; Fdez-Riverola, Florentino; Lourenço, Anália

    2015-02-01

    Document annotation is a key task in the development of Text Mining methods and applications. High quality annotated corpora are invaluable, but their preparation requires a considerable amount of resources and time. Although the existing annotation tools offer good user interaction interfaces to domain experts, project management and quality control abilities are still limited. Therefore, the current work introduces Marky, a new Web-based document annotation tool equipped to manage multi-user and iterative projects, and to evaluate annotation quality throughout the project life cycle. At the core, Marky is a Web application based on the open source CakePHP framework. User interface relies on HTML5 and CSS3 technologies. Rangy library assists in browser-independent implementation of common DOM range and selection tasks, and Ajax and JQuery technologies are used to enhance user-system interaction. Marky grants solid management of inter- and intra-annotator work. Most notably, its annotation tracking system supports systematic and on-demand agreement analysis and annotation amendment. Each annotator may work over documents as usual, but all the annotations made are saved by the tracking system and may be further compared. So, the project administrator is able to evaluate annotation consistency among annotators and across rounds of annotation, while annotators are able to reject or amend subsets of annotations made in previous rounds. As a side effect, the tracking system minimises resource and time consumption. Marky is a novel environment for managing multi-user and iterative document annotation projects. Compared to other tools, Marky offers a similar visually intuitive annotation experience while providing unique means to minimise annotation effort and enforce annotation quality, and therefore corpus consistency. Marky is freely available for non-commercial use at http://sing.ei.uvigo.es/marky. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. A game-theoretical pricing mechanism for multiuser rate allocation for video over WiMAX

    NASA Astrophysics Data System (ADS)

    Chen, Chao-An; Lo, Chi-Wen; Lin, Chia-Wen; Chen, Yung-Chang

    2010-07-01

    In multiuser rate allocation in a wireless network, strategic users can bias the rate allocation by misrepresenting their bandwidth demands to a base station, leading to an unfair allocation. Game-theoretical approaches have been proposed to address the unfair allocation problems caused by the strategic users. However, existing approaches rely on a timeconsuming iterative negotiation process. Besides, they cannot completely prevent unfair allocations caused by inconsistent strategic behaviors. To address these problems, we propose a Search Based Pricing Mechanism to reduce the communication time and to capture a user's strategic behavior. Our simulation results show that the proposed method significantly reduce the communication time as well as converges stably to an optimal allocation.

  3. Self-sustained lift and low friction via soft lubrication

    PubMed Central

    Saintyves, Baudouin; Jules, Theo; Salez, Thomas; Mahadevan, L.

    2016-01-01

    Relative motion between soft wet solids arises in a number of applications in natural and artificial settings, and invariably couples elastic deformation fluid flow. We explore this in a minimal setting by considering a fluid-immersed negatively buoyant cylinder moving along a soft inclined wall. Our experiments show that there is an emergent robust steady-state sliding regime of the cylinder with an effective friction that is significantly reduced relative to that of rigid fluid-lubricated contacts. A simple scaling approach that couples the cylinder-induced flow to substrate deformation allows us to explain the elastohydrodynamic lift that underlies the self-sustained lubricated motion of the cylinder, consistent with recent theoretical predictions. Our results suggest an explanation for a range of effects such as reduced wear in animal joints and long-runout landslides, and can be couched as a design principle for low-friction interfaces. PMID:27162361

  4. Advanced Hemophilic Arthropathy: Sensitivity of Soft Tissue Discrimination With Musculoskeletal Ultrasound.

    PubMed

    von Drygalski, Annette; Moore, Randy E; Nguyen, Sonha; Barnes, Richard F W; Volland, Lena M; Hughes, Tudor H; Du, Jiang; Chang, Eric Y

    2018-01-24

    Point-of-care musculoskeletal ultrasound (US) is increasingly used by hemophilia providers to guide management; however, pathologic tissue differentiation with US is uncertain. We sought to determine the extent to which point-of-care musculoskeletal US can identify and discriminate pathologic soft tissue changes in hemophilic arthropathy. Thirty-six adult patients with hemophilia A/B were prospectively enrolled. Point-of-care musculoskeletal US examinations were performed on arthropathic joints (16 knees, 10 ankles, and 10 elbows) using standard views by a musculoskeletal US-trained and certified hematologist, who recorded abnormal intra-articular soft tissue accumulation. Within 3 days, magnetic resonance imaging was performed using conventional and multiecho ultrashort echo time sequences. Soft tissue identification (synovial proliferation with or without hemosiderin, fat, and/or blood products) was performed by a musculoskeletal radiologist. Findings obtained with both imaging modalities were compared and correlated in a blinded fashion. There was perfect agreement between the modalities on the presence of abnormal soft tissue (34 of 36 cases). However, musculoskeletal US was unable to discriminate between coagulated blood, synovium, intrasynovial or extrasynovial fat tissue, or hemosiderin deposits because of wide variations in echogenicity. Musculoskeletal US is valuable for point-of-care imaging to determine the presence of soft tissue accumulation in discrete areas. However, because of limitations of musculoskeletal US in discriminating the nature of pathologic soft tissues and detecting hemosiderin, magnetic resonance imaging will be required if such discrimination is clinically important. © 2018 by the American Institute of Ultrasound in Medicine.

  5. Computed tomographic anatomy of the equine stifle joint.

    PubMed

    Vekens, Elke Van der; Bergman, Erik H J; Vanderperren, Katrien; Raes, Els V; Puchalski, Sarah M; Bree, Henri J J van; Saunders, Jimmy H

    2011-04-01

    To provide a detailed computed tomography (CT) reference of the anatomically normal equine stifle joint. Sample-16 hind limbs from 8 equine cadavers; no horses had evidence of orthopedic disease of the stifle joints. CT of the stifle joint was performed on 8 hind limbs. In all limbs, CT was also performed after intra-articular injection of 60 mL of contrast material (150 mg of iodine/mL) in the lateral and medial compartments of the femorotibial joint and 80 mL of contrast material in the femoropatellar joint (CT arthrography). Reformatted CT images in the transverse, parasagittal, and dorsal plane were matched with corresponding anatomic slices of the 8 remaining limbs. The femur, tibia, and patella were clearly visible. The patellar ligaments, common origin of the tendinous portions of the long digital extensor muscle and peroneus tertius muscle, collateral ligaments, tendinous portion of the popliteus muscle, and cranial and caudal cruciate ligaments could also be consistently evaluated. The cruciate ligaments and the meniscotibial ligaments could be completely assessed in the arthrogram sequences. Margins of the meniscofemoral ligament and the lateral and medial femoropatellar ligaments were difficult to visualize on the precontrast and postcontrast images. CT and CT arthrography were used to accurately identify and characterize osseous and soft tissue structures of the equine stifle joint. This technique may be of value when results from other diagnostic imaging techniques are inconclusive. The images provided will serve as a CT reference for the equine stifle joint.

  6. A Soft OR Approach to Fostering Systems Thinking: SODA Maps plus Joint Analytical Process

    ERIC Educational Resources Information Center

    Wang, Shouhong; Wang, Hai

    2016-01-01

    Higher order thinking skills are important for managers. Systems thinking is an important type of higher order thinking in business education. This article investigates a soft Operations Research approach to teaching and learning systems thinking. It outlines the integrative use of Strategic Options Development and Analysis maps for visualizing…

  7. Investigation of improved designs for rotational micromirrors using multiuser MEMS processes

    NASA Astrophysics Data System (ADS)

    Lin, Julianna E.; Michael, Feras S. J.; Kirk, Andrew G.

    2001-04-01

    In recent years, the design of rotational micromirrors for use in optical cross connects has received much attention. Although several companies have already produced and marketed a number of torsional mirror devices, more work is still needed to determine how these mirrors can be integrated into optical systems to form compact optical switches. However, recently several commercial MEMS foundry services have become available. Thus, due to the low cost of these prototyping services, new devices can be fabricated in short amounts of time and the designs adapted to meet the needs of different applications. The purpose of this work is to investigate the fabrication of new micromirror designs using the Multi-User MEMS Processes (MUMPs) foundry service available from Cronos Integrated Microsystems, located in North Carolina, USA). Several sets of mirror designs were submitted for fabrication and the resulting structures characterized using a phase-shifting Mirau interferometer. The results of these devices are presented.

  8. Comparison of two underwater acoustic communications techniques for multi-user access

    NASA Astrophysics Data System (ADS)

    Hursky, Paul; Siderius, T. Martin; Kauaiex Group

    2004-05-01

    Frequency hopped frequency shift keying (FHFSK) and code division multiple access (CDMA) are two different modulation techniques for multiple users to communicate with a single receiver simultaneously. In July 2003, these two techniques were tested alongside each other in a shallow water coastal environment off the coast of Kauai. A variety of instruments were used to measure the prevailing oceanography, enabling detailed modeling of the channel. The channel was acoustically probed using LFM waveforms and m-sequences as well. We will present the results of demodulating the FHFSK and CDMA waveforms and discuss modeling the channel for the purpose of predicting multi-user communications performance. a)Michael B. Porter, Paul Hursky, Martin Siderius (SAIC), Mohsen Badiey (UD), Jerald Caruthers (USM), William S. Hodgkiss, Kaustubha Raghukumar (SIO), Dan Rouseff, Warren Fox (APL-UW), Christian de Moustier, Brian Calder, Barbara J. Kraft (UNH), Keyko McDonald (SPAWARSSC), Peter Stein, James K. Lewis, and Subramaniam Rajan (SSI).

  9. Hyperextension soft tissue injuries of the cervical spine--a review.

    PubMed Central

    Johnson, G

    1996-01-01

    While a full understanding of continuing symptoms following a soft tissue hyperextension injury of the cervical spine remains elusive, recent research has shown that the explanation may lie with occult lesions beyond the musculoskeletal structures of the neck. The balance of the roles of injury, psychological factors, and the effects of litigation has shifted towards the former. However this injury would be unique if the latter two played only a minor role in determining recovery. It seems likely that among the large numbers of patients presenting with symptoms after hyperextension soft tissue injuries, a proportion will have occult bone, joint, or intervertebral disc lesions. Improvements in medical imaging techniques may allow better definition of these specific injuries and the development of more appropriate treatment. The search for a central nervous system lesion in humans continues and until this is demonstrated, many will dispute the existence of an organic brain syndrome. Evidence for significant injury to the temporomandibular joints, ear, and ophthalmic system has been found and this may be amenable to specialist intervention. While there is little evidence for effective treatments of the established injury, reduction in related disability appears most likely to be achieved by prevention. Improvements in automobile design, with particular reference to head restraints, could limit the cost to society of this common and disabling injury. PMID:8821214

  10. Controlling joint pain in older people.

    PubMed

    Paisley, Peter; Serpell, Mick

    2016-01-01

    Jont pain in oldder people The prevalence of chronic pain in older people in the community ranges from 25 to 76% and for those in residential care, it is even higher at 83 to 93%. The most common sites affected are the back, hip, or knee, and other joints. There is increased reporting of pain in women (79%) compared with men (53%). Common conditions include osteoarthritis and, to a lesser extent, the inflammatory arthropathies such as rheumatoid arthritis. The differential diagnosis includes non-articular pain such as vascular limb pain and nocturnal cramp, some neuropathic pain conditions (such as compressive neuropathies and postherpetic neuralgia), soft tissue disorders such as fibromyalgia and myofascial pain syndromes. In addition to an assessment of pain intensity, a biopsychosocial model should be adopted to ascertain the effect of the pain on the patient's degree of background pain at rest. The disease is often localised to the large load-bearing joints, predominantly the hips and knees. In contrast to osteoarthritis, the inflammatory arthritides typically present with symmetrical swollen, stiff, and painful small joints of the hands and feet, usually worse in the morning.

  11. Joint operations planning for space surveillance missions on the MSX satellite

    NASA Technical Reports Server (NTRS)

    Stokes, Grant; Good, Andrew

    1994-01-01

    The Midcourse Space Experiment (MSX) satellite, sponsored by BMDO, is intended to gather broad-band phenomenology data on missiles, plumes, naturally occurring earthlimb backgrounds and deep space backgrounds. In addition the MSX will be used to conduct functional demonstrations of space-based space surveillance. The JHU/Applied Physics Laboratory (APL), located in Laurel, MD, is the integrator and operator of the MSX satellite. APL will conduct all operations related to the MSX and is charged with the detailed operations planning required to implement all of the experiments run on the MSX except the space surveillance experiments. The non-surveillance operations are generally amenable to being defined months ahead of time and being scheduled on a monthly basis. Lincoln Laboratory, Massachusetts Institute of Technology (LL), located in Lexington, MA, is the provider of one of the principle MSX instruments, the Space-Based Visible (SBV) sensor, and the agency charged with implementing the space surveillance demonstrations on the MSX. The planning timelines for the space surveillance demonstrations are fundamentally different from those for the other experiments. They are generally amenable to being scheduled on a monthly basis, but the specific experiment sequence and pointing must be refined shortly before execution. This allocation of responsibilities to different organizations implies the need for a joint mission planning system for conducting space surveillance demonstrations. This paper details the iterative, joint planning system, based on passing responsibility for generating MSX commands for surveillance operations from APL to LL for specific scheduled operations. The joint planning system, including the generation of a budget for spacecraft resources to be used for surveillance events, has been successfully demonstrated during ground testing of the MSX and is being validated for MSX launch within the year. The planning system developed for the MSX forms a

  12. Histopathologic evaluation of the effects of etodolac in established adjuvant arthritis in rats: evidence for reversal of joint damage.

    PubMed

    Weichman, B M; Chau, T T; Rona, G

    1987-04-01

    Histopathologic evaluation of hindpaws from control rats with established adjuvant arthritis showed severe alterations in soft tissue and bone, as well as progressive, moderate-to-severe articular changes. Following treatment with etodolac for 28 days, soft tissue and articular changes were rated mild, and bone changes were rated moderate, but with remodeling. These findings indicate that etodolac partially reversed the joint damage in these rats.

  13. Precharged Pneumatic Soft Actuators and Their Applications to Untethered Soft Robots.

    PubMed

    Li, Yunquan; Chen, Yonghua; Ren, Tao; Li, Yingtian; Choi, Shiu Hong

    2018-06-20

    The past decade has witnessed tremendous progress in soft robotics. Unlike most pneumatic-based methods, we present a new approach to soft robot design based on precharged pneumatics (PCP). We propose a PCP soft bending actuator, which is actuated by precharged air pressure and retracted by inextensible tendons. By pulling or releasing the tendons, the air pressure in the soft actuator is modulated, and hence, its bending angle. The tendons serve in a way similar to pressure-regulating valves that are used in typical pneumatic systems. The linear motion of tendons is transduced into complex motion via the prepressurized bent soft actuator. Furthermore, since a PCP actuator does not need any gas supply, complicated pneumatic control systems used in traditional soft robotics are eliminated. This facilitates the development of compact untethered autonomous soft robots for various applications. Both theoretical modeling and experimental validation have been conducted on a sample PCP soft actuator design. A fully untethered autonomous quadrupedal soft robot and a soft gripper have been developed to demonstrate the superiority of the proposed approach over traditional pneumatic-driven soft robots.

  14. Action tagging in a multi-user indoor environment for behavioural analysis purposes.

    PubMed

    Guerra, Claudio; Bianchi, Valentina; De Munari, Ilaria; Ciampolini, Paolo

    2015-01-01

    EU population is getting older, so that ICT-based solutions are expected to provide support in the challenges implied by the demographic change. At the University of Parma an AAL (Ambient Assisted Living) system, named CARDEA, has been developed. In this paper a new feature of the system is introduced, in which environmental and personal (i.e., wearable) sensors coexist, providing an accurate picture of the user's activity and needs. Environmental devices may greatly help in performing activity recognition and behavioral analysis tasks. However, in a multi-user environment, this implies the need of attributing environmental sensors outcome to a specific user, i.e., identifying the user when he performs a task detected by an environmental device. We implemented such an "action tagging" feature, based on information fusion, within the CARDEA environment, as an inexpensive, alternative solution to the problematic issue of indoor locationing.

  15. Antimicrobial efficacy assessment of multi-use solution to disinfect hydrophilic contact lens, in vitro.

    PubMed

    Lui, Aline Cristina Fioravanti; Netto, Adamo Lui; Silva, Cely Barreto da; Hida, Richard; Mendes, Thais Sousa; Lui, Giovana Arlene Fioravanti; Gemperli, Daniela Barbosa; Vital, Enderson Dantas

    2009-01-01

    To evaluate the efficacy of disinfecting solutions in hydrophilic contact lenses (CL). Two multi-use solutions denominated solution A (0.001% polyquaternium-1 and 0.0005% myristamidopropyl dimethylamine) and solution B (0.0001% polyaminopropyl biguanide) were used. The solutions were tested in hydrophilic contact lenses infected with Pseudomonas aeruginosa (ATCC27583), Staphylococcus epidermidis (ATCC1226), Klebsiella pneumoniae (ATCC13883), Staphylococcus aureus (ATCC25923) and Candida albicans (ATCC 10231) and the decrease in microorganisms growth after the hydrophilic contact lenses were cleaned with the respective solutions was verified. The manufacture's instructions were followed. A decrease of 90% of Pseudomonas aeruginosa, Staphylococcus epidermidis, Staphylococcus aureus, Candida albicans and a decrease 100% of Klebsiella pneumoniae was observed. The solutions decreased the amount of microorganisms tested.

  16. Occupational asthma due to soft corrosive soldering fluxes containing zinc chloride and ammonium chloride.

    PubMed Central

    Weir, D C; Robertson, A S; Jones, S; Burge, P S

    1989-01-01

    Two cases of occupational asthma due to soft corrosive soldering fluxes used in metal jointing are described in which the diagnosis was based on work related deterioration in daily peak expiratory flow rate and positive responses in bronchial provocation tests. Both fluxes contained ammonium chloride and zinc chloride. Occupational asthma provoked by these agents has not previously been reported. PMID:2705153

  17. Microstructure and Hardness Profiles of Bifocal Laser-Welded DP-HSLA Steel Overlap Joints

    NASA Astrophysics Data System (ADS)

    Grajcar, A.; Matter, P.; Stano, S.; Wilk, Z.; Różański, M.

    2017-04-01

    The article presents results related to the bifocal laser welding of overlap joints made of HSLA and DP high-strength steels. The joints were made using a disk laser and a head enabling the 50-50% distribution of laser power. The effects of the laser welding rates and the distance between laser spots on morphological features and hardness profiles were analyzed. It was established that the positioning of beams at angles of 0° or 90° determined the hardness of the individual zones of the joints, without causing significant differences in microstructures of the steels. Microstructural features were inspected using scanning electron microscopy. Both steels revealed primarily martensitic-bainitic microstructures in the fusion zone and in the heat-affected zone. Mixed multiphase microstructures were revealed in the inter-critical heat-affected zone of the joint. The research involved the determination of parameters making it possible to reduce the hardness of joints and prevent the formation of the soft zone in the dual-phase steel.

  18. [Arthroscopic excision of elastofibroma dorsi at scapulothoracic joint: a surgical technique].

    PubMed

    Çakmak, Gökhan; Ergün, Tarkan; Şahin, M Şükrü

    2014-01-01

    Elastofibroma dorsi is a rare soft tissue pseudotumor which is located at the anteroinferior aspect of the scapula. In this article, we report a 19-year-old female case who had arthroscopic marginal excision of elastofibroma dorsi at the scapulothoracic joint without recurrences during follow-up. The arthroscopic marginal excision of the elastofibroma dorsi may have good clinical results in selected cases.

  19. Functional anatomy of the distal radioulnar joint in health and disease.

    PubMed

    Lees, V C

    2013-04-01

    The distal radioulnar joint (DRUJ) is critical to the function of the forearm as a mechanical unit. This paper is concerned with the concepts and observations that have changed understanding of the function of the DRUJ, notably with respect to the biomechanics of this joint. The DRUJ has been shown to be important in acting to distribute load and removal of the ulna head leads to the biomechanical equivalent of a one-bone forearm. The soft tissues with topographical relations to the distal forearm and DRUJ have also been investigated in our experimental series with findings including the description of a clinical disorder termed subluxation-related ulna neuropathy syndrome.

  20. Soft electronics for soft robotics

    NASA Astrophysics Data System (ADS)

    Kramer, Rebecca K.

    2015-05-01

    As advanced as modern machines are, the building blocks have changed little since the industrial revolution, leading to rigid, bulky, and complex devices. Future machines will include electromechanical systems that are soft and elastically deformable, lending them to applications such as soft robotics, wearable/implantable devices, sensory skins, and energy storage and transport systems. One key step toward the realization of soft systems is the development of stretchable electronics that remain functional even when subject to high strains. Liquid-metal traces embedded in elastic polymers present a unique opportunity to retain the function of rigid metal conductors while leveraging the deformable properties of liquid-elastomer composites. However, in order to achieve the potential benefits of liquid-metal, scalable processing and manufacturing methods must be identified.

  1. Design and Characterization of a Soft Robotic Therapeutic Glove for Rheumatoid Arthritis.

    PubMed

    Chua, Matthew Chin Heng; Lim, Jeong Hoon; Yeow, Raye Chen Hua

    2017-07-27

    The modeling and experimentation of a pneumatic actuation system for the development of a soft robotic therapeutic glove is proposed in this article for the prevention of finger deformities in rheumatoid arthritis (RA) patients. The Rehabilitative Arthritis Glove (RA-Glove) is a soft robotic glove fitted with two internal inflatable actuators for lateral compression and massage of the fingers and their joints. Two mechanical models to predict the indentation and bending characteristics of the inflatable actuators based on their geometrical parameters will be presented and validated with experimental results. Experimental validation shows that the model was within a standard deviation of the experimental mean for input pressure range of 0 to 2 bars. Evaluation of the RA-Glove was also performed on six healthy human subjects. The stress distribution along the fingers of the subjects using the RA-Glove was also shown to be even and specific to the finger sizes. This article demonstrates the modeling of soft pneumatic actuators and highlights the potential of the RA-Glove as a therapeutic device for the prevention of arthritic deformities of the fingers.

  2. Soft versus hard occlusal splint therapy in the management of temporomandibular disorders (TMDs)

    PubMed Central

    Seifeldin, Sameh A; Elhayes, Khaled A.

    2015-01-01

    Aim To compare between soft and hard occlusal splint therapy for the management of myofacial pain dysfunction (MPD) or internal derangement (ID) of the temporomandibular joint (TMJ) with reciprocal clicking. Patients and methods This study included 50 patients (age range: 24–47 years) who had been diagnosed with MPD or ID of the TMJ in the form of reciprocal clicking. Patients were divided into two groups. They were treated for 4 months with either a vacuum-formed soft occlusal splint constructed from 2-mm-thick elastic rubber sheets (soft splint group) or a hard flat occlusal splint fabricated from transparent acrylic resin (hard splint group). Monthly follow-up visits were performed during the treatment period. Before treatment and 1, 2, 3 and 4 months after treatment, the dentist measured all parameters of TMJ function (pain visual analog scores, tenderness of masticatory muscles, clicking and tenderness of the TMJ, and range of mouth opening). Results All parameters of TMJ function showed significant improvement in both groups during the follow-up period, with a statistically significant difference between the two groups at the 4-month follow-up visit. Conclusions Both forms of occlusal splints (soft and hard) improved TMJ symptoms in patients with MPD or ID of the TMJ. However, the soft occlusal splints exhibited superior results after 4 months of use. PMID:26644756

  3. Tumours of bones and joints

    PubMed Central

    Misdorp, W.; Van Der Heul, R. O.

    1976-01-01

    Tumours of bones and joints are not infrequent in dogs but are rare in other domestic animals. In the dog, most bone tumours are malignant; osteosarcomas are by far the most frequently encountered tumours, especially in giant breeds and boxers. The following main categories of bone tumour are described: bone-forming, cartilage-forming, giant cell, marrow, vascular, miscellaneous, metastatic, unclassified, and tumour-like lesions. The tumours of joints and related structures are classified as synovial sarcomas, fibroxanthomas, and malignant giant cell tumour of soft tissues. ImagesFig. 21Fig. 22Fig. 23Fig. 24Fig. 17Fig. 18Fig. 19Fig. 20Fig. 29Fig. 30Fig. 31Fig. 32Fig. 33Fig. 34Fig. 35Fig. 36Fig. 25Fig. 26Fig. 27Fig. 28Fig. 1Fig. 2Fig. 3Fig. 4Fig. 37Fig. 38Fig. 39Fig. 40Fig. 5Fig. 6Fig. 7Fig. 8Fig. 13Fig. 14Fig. 15Fig. 16Fig. 9Fig. 10Fig. 11Fig. 12 PMID:1086157

  4. Soft Robotic Grippers.

    PubMed

    Shintake, Jun; Cacucciolo, Vito; Floreano, Dario; Shea, Herbert

    2018-05-07

    Advances in soft robotics, materials science, and stretchable electronics have enabled rapid progress in soft grippers. Here, a critical overview of soft robotic grippers is presented, covering different material sets, physical principles, and device architectures. Soft gripping can be categorized into three technologies, enabling grasping by: a) actuation, b) controlled stiffness, and c) controlled adhesion. A comprehensive review of each type is presented. Compared to rigid grippers, end-effectors fabricated from flexible and soft components can often grasp or manipulate a larger variety of objects. Such grippers are an example of morphological computation, where control complexity is greatly reduced by material softness and mechanical compliance. Advanced materials and soft components, in particular silicone elastomers, shape memory materials, and active polymers and gels, are increasingly investigated for the design of lighter, simpler, and more universal grippers, using the inherent functionality of the materials. Embedding stretchable distributed sensors in or on soft grippers greatly enhances the ways in which the grippers interact with objects. Challenges for soft grippers include miniaturization, robustness, speed, integration of sensing, and control. Improved materials, processing methods, and sensing play an important role in future research. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. [Development of polyaxial locking plate screw system of sacroiliac joint].

    PubMed

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P > 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than

  6. Soft Robotics.

    PubMed

    Whitesides, George M

    2018-04-09

    This description of "soft robotics" is not intended to be a conventional review, in the sense of a comprehensive technical summary of a developing field. Rather, its objective is to describe soft robotics as a new field-one that offers opportunities to chemists and materials scientists who like to make "things" and to work with macroscopic objects that move and exert force. It will give one (personal) view of what soft actuators and robots are, and how this class of soft devices fits into the more highly developed field of conventional "hard" robotics. It will also suggest how and why soft robotics is more than simply a minor technical "tweak" on hard robotics and propose a unique role for chemistry, and materials science, in this field. Soft robotics is, at its core, intellectually and technologically different from hard robotics, both because it has different objectives and uses and because it relies on the properties of materials to assume many of the roles played by sensors, actuators, and controllers in hard robotics. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. MRI evaluation of anterolateral soft tissue impingement of the ankle.

    PubMed

    Ferkel, Richard D; Tyorkin, Max; Applegate, Gregory R; Heinen, Gregory T

    2010-08-01

    The usefulness of magnetic resonance imaging (MRI) has been questioned in evaluating patients with chronic ankle sprain pain. The purpose of this study was to determine the effectiveness and reliability of routine MR imaging in the diagnosis of anterolateral soft tissue impingement. Inclusion criteria required that the MR examinations be performed by the same musculoskeletal radiologist after the most recent scanner upgrade and using a dedicated ankle/hindfoot coil. The surgical and MRI reports of 24 patients who had an arthroscopic diagnosis of anterolateral soft tissue impingement of the ankle were tabulated and categorized. Unlike previous studies, sagittal T1 and Short Tau Inversion Recovery (STIR) images were used primarily in the diagnosis of these lesions. Using this technique, we report a 78.9% accuracy in diagnosis, a sensitivity of 83.3% and a specificity of 78.6%. Fifty-eight percent of patients had an associated diagnosis, which in 33% of patients altered our surgical plan. Although not indicated in all cases of anterolateral ankle impingement, we advocate the use of MR imaging in complicated clinical presentations where the exclusion of additional pathology in the ankle or subtalar joint, and the confirmation of anterolateral soft tissue impingement would be beneficial.

  8. Hierarchical Compliance Control of a Soft Ankle Rehabilitation Robot Actuated by Pneumatic Muscles.

    PubMed

    Liu, Quan; Liu, Aiming; Meng, Wei; Ai, Qingsong; Xie, Sheng Q

    2017-01-01

    Traditional compliance control of a rehabilitation robot is implemented in task space by using impedance or admittance control algorithms. The soft robot actuated by pneumatic muscle actuators (PMAs) is becoming prominent for patients as it enables the compliance being adjusted in each active link, which, however, has not been reported in the literature. This paper proposes a new compliance control method of a soft ankle rehabilitation robot that is driven by four PMAs configured in parallel to enable three degrees of freedom movement of the ankle joint. A new hierarchical compliance control structure, including a low-level compliance adjustment controller in joint space and a high-level admittance controller in task space, is designed. An adaptive compliance control paradigm is further developed by taking into account patient's active contribution and movement ability during a previous period of time, in order to provide robot assistance only when it is necessarily required. Experiments on healthy and impaired human subjects were conducted to verify the adaptive hierarchical compliance control scheme. The results show that the robot hierarchical compliance can be online adjusted according to the participant's assessment. The robot reduces its assistance output when participants contribute more and vice versa , thus providing a potentially feasible solution to the patient-in-loop cooperative training strategy.

  9. Hierarchical Compliance Control of a Soft Ankle Rehabilitation Robot Actuated by Pneumatic Muscles

    PubMed Central

    Liu, Quan; Liu, Aiming; Meng, Wei; Ai, Qingsong; Xie, Sheng Q.

    2017-01-01

    Traditional compliance control of a rehabilitation robot is implemented in task space by using impedance or admittance control algorithms. The soft robot actuated by pneumatic muscle actuators (PMAs) is becoming prominent for patients as it enables the compliance being adjusted in each active link, which, however, has not been reported in the literature. This paper proposes a new compliance control method of a soft ankle rehabilitation robot that is driven by four PMAs configured in parallel to enable three degrees of freedom movement of the ankle joint. A new hierarchical compliance control structure, including a low-level compliance adjustment controller in joint space and a high-level admittance controller in task space, is designed. An adaptive compliance control paradigm is further developed by taking into account patient’s active contribution and movement ability during a previous period of time, in order to provide robot assistance only when it is necessarily required. Experiments on healthy and impaired human subjects were conducted to verify the adaptive hierarchical compliance control scheme. The results show that the robot hierarchical compliance can be online adjusted according to the participant’s assessment. The robot reduces its assistance output when participants contribute more and vice versa, thus providing a potentially feasible solution to the patient-in-loop cooperative training strategy. PMID:29255412

  10. Simulation study on dynamics model of two kinds of on-orbit soft-contact mechanism

    NASA Astrophysics Data System (ADS)

    Ye, X.; Dong, Z. H.; Yang, F.

    2018-05-01

    Aiming at the problem that the operating conditions of the space manipulator is harsh and the space manipulator could not bear the large collision momentum, this paper presents a new concept and technical method, namely soft contact technology. Based on ADAMS dynamics software, this paper compares and simulates the mechanism model of on-orbit soft-contact mechanism based on the bionic model and the integrated double joint model. The main purpose is to verify the path planning ability and the momentum buffering ability based on the different design concept mechanism. The simulation results show that both the two mechanism models have the path planning function before the space target contact, and also has the momentum buffer and controllability during the space target contact process.

  11. Soft lubrication

    NASA Astrophysics Data System (ADS)

    Skotheim, Jan; Mahadevan, Laksminarayanan

    2004-11-01

    We study the lubrication of fluid-immersed soft interfaces and show that elastic deformation couples tangential and normal forces and thus generates lift. We consider materials that deform easily, due to either geometry (e.g a shell) or constitutive properties (e.g. a gel or a rubber), so that the effects of pressure and temperature on the fluid properties may be neglected. Four different system geometries are considered: a rigid cylinder moving tangentially to a soft layer coating a rigid substrate; a soft cylinder moving tangentially to a rigid substrate; a cylindrical shell moving tangentially to a rigid substrate; and finally a journal bearing coated with a thin soft layer, which being a conforming contact allows us to gauge the influence of contact geometry. In addition, for the particular case of a soft layer coating a rigid substrate we consider both elastic and poroelastic material responses. Finally, we consider the role of contact geometry in the context of the journal bearing, a conforming contact. For all these cases we find the same generic behavior: there is an optimal combination of geometric and material parameters that maximizes the dimensionless normal force as a function of the softness.

  12. Joint Source-Channel Coding by Means of an Oversampled Filter Bank Code

    NASA Astrophysics Data System (ADS)

    Marinkovic, Slavica; Guillemot, Christine

    2006-12-01

    Quantized frame expansions based on block transforms and oversampled filter banks (OFBs) have been considered recently as joint source-channel codes (JSCCs) for erasure and error-resilient signal transmission over noisy channels. In this paper, we consider a coding chain involving an OFB-based signal decomposition followed by scalar quantization and a variable-length code (VLC) or a fixed-length code (FLC). This paper first examines the problem of channel error localization and correction in quantized OFB signal expansions. The error localization problem is treated as an[InlineEquation not available: see fulltext.]-ary hypothesis testing problem. The likelihood values are derived from the joint pdf of the syndrome vectors under various hypotheses of impulse noise positions, and in a number of consecutive windows of the received samples. The error amplitudes are then estimated by solving the syndrome equations in the least-square sense. The message signal is reconstructed from the corrected received signal by a pseudoinverse receiver. We then improve the error localization procedure by introducing a per-symbol reliability information in the hypothesis testing procedure of the OFB syndrome decoder. The per-symbol reliability information is produced by the soft-input soft-output (SISO) VLC/FLC decoders. This leads to the design of an iterative algorithm for joint decoding of an FLC and an OFB code. The performance of the algorithms developed is evaluated in a wavelet-based image coding system.

  13. Effect of Zinc Coatings on Joint Properties and Interfacial Reactions in Aluminum to Steel Ultrasonic Spot Welding

    NASA Astrophysics Data System (ADS)

    Haddadi, F.; Strong, D.; Prangnell, P. B.

    2012-03-01

    Dissimilar joining of aluminum to steel sheet in multimaterial automotive structures is an important potential application of ultrasonic spot welding (USW). Here, the weldability of different zinc-coated steels with aluminum is discussed, using a 2.5-kW USW welder. Results show that soft hot-dipped zinc (DX56-Z)-coated steel results in better weld performance than hard (galv-annealed) zinc coatings (DX53-ZF). For Al to hard galv-annealed-coated steel welds, lap shear strengths reached a maximum of ~80% of the strength of an Al-Al joint after a 1.0 s welding time. In comparison, welds between Al6111-T4 and hot dipped soft zinc-coated steel took longer to achieve the same maximum strength, but nearly matched the Al-Al joint properties. The reasons for these different behaviors are discussed in terms of the interfacial reactions between the weld members.

  14. Macrobend optical sensing for pose measurement in soft robot arms

    NASA Astrophysics Data System (ADS)

    Sareh, Sina; Noh, Yohan; Li, Min; Ranzani, Tommaso; Liu, Hongbin; Althoefer, Kaspar

    2015-12-01

    This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic

  15. Equivalent dynamic model of DEMES rotary joint

    NASA Astrophysics Data System (ADS)

    Zhao, Jianwen; Wang, Shu; Xing, Zhiguang; McCoul, David; Niu, Junyang; Huang, Bo; Liu, Liwu; Leng, Jinsong

    2016-07-01

    The dielectric elastomer minimum energy structure (DEMES) can realize large angular deformations by a small voltage-induced strain of the dielectric elastomer (DE), so it is a suitable candidate to make a rotary joint for a soft robot. Dynamic analysis is necessary for some applications, but the dynamic response of DEMESs is difficult to model because of the complicated morphology and viscoelasticity of the DE film. In this paper, a method composed of theoretical analysis and experimental measurement is presented to model the dynamic response of a DEMES rotary joint under an alternating voltage. Based on measurements of equivalent driving force and damping of the DEMES, the model can be derived. Some experiments were carried out to validate the equivalent dynamic model. The maximum angle error between model and experiment is greater than ten degrees, but it is acceptable to predict angular velocity of the DEMES, therefore, it can be applied in feedforward-feedback compound control.

  16. Soft Congruence Relations over Rings

    PubMed Central

    Xin, Xiaolong; Li, Wenting

    2014-01-01

    Molodtsov introduced the concept of soft sets, which can be seen as a new mathematical tool for dealing with uncertainty. In this paper, we initiate the study of soft congruence relations by using the soft set theory. The notions of soft quotient rings, generalized soft ideals and generalized soft quotient rings, are introduced, and several related properties are investigated. Also, we obtain a one-to-one correspondence between soft congruence relations and idealistic soft rings and a one-to-one correspondence between soft congruence relations and soft ideals. In particular, the first, second, and third soft isomorphism theorems are established, respectively. PMID:24949493

  17. The Soft X-ray Imager (SXI) on the SMILE Mission

    NASA Astrophysics Data System (ADS)

    Sembay, S.; Branduardi-Raymont, G.; Drumm, P.; Escoubet, C. P.; Genov, G.; Gow, J.; Hall, D.; Holland, A.; Hudec, R.; Mas-Hesse, J. M.; Kennedy, T.; Kuntz, K. D.; Nakamura, R.; Ostgaard, N.; Ottensamer, R.; Raab, W.; Read, A.; Rebuffat, D.; Romstedt, J.; Schyns, E.; Sibeck, D. G.; Srp, A.; Steller, M.; Sun, T.; Sykes, J. M.; Thornhill, J.; Walsh, B.; Walton, D.; Wang, C.; Wei, F.; Wielders, A.; Whittaker, I. C.

    2016-12-01

    SMILE (Solar wind Magnetosphere Ionosphere Link Explorer) is a space mission dedicated to study the interaction of the solar wind with the Earth's magnetic field. SMILE will investigate the dynamic response of the Earth's magnetosphere to the impact of the solar wind in a unique manner, never attempted before: it will combine soft X-ray imaging of the Earth's magnetic boundaries and magnetospheric cusps with simultaneous UV imaging of the Northern aurora, while simultaneously providing context measurements via an in situ plasma and magnetometer instrument package. SMILE is a joint European Space Agency (ESA) and Chinese Academy of Sciences (CAS) collaborative mission due for launch in 2021. This talk will describe the Soft X-ray Imager (SXI) on SMILE. The SXI is designed for good detection sensitivity of the soft X-rays (0.2 - 2.0 keV) produced in the Earth's exosphere by the solar wind charge exchange process. This process is the mechanism by which it is possible to globally image the Earth's dayside magnetosheath, magnetopause boundary, bowshock and cusps. The wide field of view of the instrument (27° x 16°) is achieved by the use of a micropore optic (MPO) with a Lobster-eye focusing geometry. The detector consists of two large format CCDs (each 8.1 cm x 6.8 cm sensitive area) providing high quantum efficiency and medium energy resolution for soft X-rays. The instrument design will be presented along with simulation results indicating the instrument sensitivity and science return.

  18. Design of a Soft Robot with Multiple Motion Patterns Using Soft Pneumatic Actuators

    NASA Astrophysics Data System (ADS)

    Miao, Yu; Dong, Wei; Du, Zhijiang

    2017-11-01

    Soft robots are made of soft materials and have good flexibility and infinite degrees of freedom in theory. These properties enable soft robots to work in narrow space and adapt to external environment. In this paper, a 2-DOF soft pneumatic actuator is introduced, with two chambers symmetrically distributed on both sides and a jamming cylinder along the axis. Fibers are used to constrain the expansion of the soft actuator. Experiments are carried out to test the performance of the soft actuator, including bending and elongation characteristics. A soft robot is designed and fabricated by connecting four soft pneumatic actuators to a 3D-printed board. The soft robotic system is then established. The pneumatic circuit is built by pumps and solenoid valves. The control system is based on the control board Arduino Mega 2560. Relay modules are used to control valves and pressure sensors are used to measure pressure in the pneumatic circuit. Experiments are conducted to test the performance of the proposed soft robot.

  19. Performance Analysis of Diversity-Controlled Multi-User Superposition Transmission for 5G Wireless Networks.

    PubMed

    Yeom, Jeong Seon; Chu, Eunmi; Jung, Bang Chul; Jin, Hu

    2018-02-10

    In this paper, we propose a novel low-complexity multi-user superposition transmission (MUST) technique for 5G downlink networks, which allows multiple cell-edge users to be multiplexed with a single cell-center user. We call the proposed technique diversity-controlled MUST technique since the cell-center user enjoys the frequency diversity effect via signal repetition over multiple orthogonal frequency division multiplexing (OFDM) sub-carriers. We assume that a base station is equipped with a single antenna but users are equipped with multiple antennas. In addition, we assume that the quadrature phase shift keying (QPSK) modulation is used for users. We mathematically analyze the bit error rate (BER) of both cell-edge users and cell-center users, which is the first theoretical result in the literature to the best of our knowledge. The mathematical analysis is validated through extensive link-level simulations.

  20. Soft-Collinear Mode for Jet Rates in Soft-Collinear Effective Theory

    DOE PAGES

    Chien, Yang-Ting; Lee, Christopher; Hornig, Andrew

    2016-01-29

    We propose the addition of a new "soft-collinear" mode to soft collinear effective theory (SCET) below the usual soft scale to factorize and resum logarithms of jet radii R in jet cross sections. We consider exclusive 2-jet cross sections in e +e - collisions with an energy veto Λ on additional jets. The key observation is that there are actually two pairs of energy scales whose ratio is R: the transverse momentum QR of the energetic particles inside jets and their total energy Q, and the transverse momentum ΛR of soft particles that are cut out of the jet cones and their energy Λ. The soft-collinear mode is necessary to factorize and resum logarithms of the latter hierarchy. We show how this factorization occurs in the jet thrust cross section for cone and k T-type algorithms at O(α s) and using the thrust cone algorithm at O(αmore » $$2\\atop{s}$$). We identify the presence of hard-collinear, in-jet soft, global (veto) soft, and soft-collinear modes in the jet thrust cross section. We also observe here that the in-jet soft modes measured with thrust are actually the "csoft" modes of the theory SCET +. We dub the new theory with both csoft and soft-collinear modes "SCET ++". We go on to explain the relation between the "unmeasured" jet function appearing in total exclusive jet cross sections and the hard-collinear and csoft functions in measured jet thrust cross sections. We do not resum logs that are non-global in origin, arising from the ratio of the scales of soft radiation whose thrust is measured at Q$${{\\tau}}$$/R and of the soft-collinear radiation at 2ΛR. Their resummation would require the introduction of additional operators beyond those we consider here. The steps we outline here are a necessary part of summing logs of R that are global in nature and have not been factorized and resummed beyond leading-log level previously.« less

  1. Soft-Collinear Mode for Jet Rates in Soft-Collinear Effective Theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chien, Yang-Ting; Lee, Christopher; Hornig, Andrew

    We propose the addition of a new "soft-collinear" mode to soft collinear effective theory (SCET) below the usual soft scale to factorize and resum logarithms of jet radii R in jet cross sections. We consider exclusive 2-jet cross sections in e +e - collisions with an energy veto Λ on additional jets. The key observation is that there are actually two pairs of energy scales whose ratio is R: the transverse momentum QR of the energetic particles inside jets and their total energy Q, and the transverse momentum ΛR of soft particles that are cut out of the jet cones and their energy Λ. The soft-collinear mode is necessary to factorize and resum logarithms of the latter hierarchy. We show how this factorization occurs in the jet thrust cross section for cone and k T-type algorithms at O(α s) and using the thrust cone algorithm at O(αmore » $$2\\atop{s}$$). We identify the presence of hard-collinear, in-jet soft, global (veto) soft, and soft-collinear modes in the jet thrust cross section. We also observe here that the in-jet soft modes measured with thrust are actually the "csoft" modes of the theory SCET +. We dub the new theory with both csoft and soft-collinear modes "SCET ++". We go on to explain the relation between the "unmeasured" jet function appearing in total exclusive jet cross sections and the hard-collinear and csoft functions in measured jet thrust cross sections. We do not resum logs that are non-global in origin, arising from the ratio of the scales of soft radiation whose thrust is measured at Q$${{\\tau}}$$/R and of the soft-collinear radiation at 2ΛR. Their resummation would require the introduction of additional operators beyond those we consider here. The steps we outline here are a necessary part of summing logs of R that are global in nature and have not been factorized and resummed beyond leading-log level previously.« less

  2. Prototyping Tool for Web-Based Multiuser Online Role-Playing Game

    NASA Astrophysics Data System (ADS)

    Okamoto, Shusuke; Kamada, Masaru; Yonekura, Tatsuhiro

    This letter proposes a prototyping tool for Web-based Multiuser Online Role-Playing Game (MORPG). The design goal is to make this tool simple and powerful. The tool is comprised of a GUI editor, a translator and a runtime environment. The GUI editor is used to edit state-transition diagrams, each of which defines the behavior of the fictional characters. The state-transition diagrams are translated into C program codes, which plays the role of a game engine in RPG system. The runtime environment includes PHP, JavaScript with Ajax and HTML. So the prototype system can be played on the usual Web browser, such as Fire-fox, Safari and IE. On a click or key press by a player, the Web browser sends it to the Web server to reflect its consequence on the screens which other players are looking at. Prospected users of this tool include programming novices and schoolchildren. The knowledge or skill of any specific programming languages is not required to create state-transition diagrams. Its structure is not only suitable for the definition of a character behavior but also intuitive to help novices understand. Therefore, the users can easily create Web-based MORPG system with the tool.

  3. Tensile and Fatigue Properties of Single and Multiple Dissimilar Welded Joints of DP980 and HSLA

    NASA Astrophysics Data System (ADS)

    Cui, Q. L.; Parkes, D.; Westerbaan, D.; Nayak, S. S.; Zhou, Y.; Saha, D. C.; Liu, D.; Goodwin, F.; Bhole, S.; Chen, D. L.

    2017-02-01

    The present study focused on single and multiple dissimilar joints between DP980 and high-strength low-alloy (HSLA) galvanized steels. The tensile properties of the dissimilar joint between the strong DP980 and the relatively soft HSLA reflected only the properties of HSLA with plastic deformation, and final fracture took place entirely in HSLA. The fatigue properties of the dissimilar joints were more intriguing, with the strong DP980 outperforming at high stress amplitude and the ductile HSLA outperforming at low stress amplitude. For different load amplitudes, fatigue failure occurred in different materials and at different locations. The fatigue strength of DP980 was more negatively impaired by weld defects than that of HSLA.

  4. Multi-Use seismic stations offer strong deterrent to clandestine nuclear weapons testing

    NASA Astrophysics Data System (ADS)

    Hennet, C. B.; Van der Vink, G. E.; Richards, P. G.; Adushkin, V. V.; Kopnichev, Y. F.; Geary, R.

    As the United States and other nations push for the signing of a Comprehensive Test Ban Treaty, representatives are meeting in Geneva this year to develop an International Seismic Monitoring System to verify compliance with the treaty's restrictions. In addition to the official monitoring system, regional networks developed for earthquake studies and basic research can provide a strong deterrent against clandestine testing. The recent release of information by the U.S. Department of Energy (DoE) on previously unannounced nuclear tests provides an opportunity to assess the ability of multi-use seismic networks to help monitor nuclear testing across the globe.Here we look at the extent to which the formerly unannounced tests were recorded and identified on the basis of publicly available seismographic data recorded by five seismic networks. The data were recorded by networks in southern Nevada and northern California at stations less than 1500 km from the Nevada Test Site (NTS), and two networks in the former Soviet Union at stations farther than 1500 km from the NTS.

  5. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    PubMed

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  6. Oral splint for temporomandibular joint disorders with revolutionary fluid system

    PubMed Central

    Srivastava, Rahul; Jyoti, Bhuvan; Devi, Parvathi

    2013-01-01

    Temporomandibular joint (TMJ) diseases and disorders refer to a complex and poorly understood set of conditions, manifested by pain in the area of the jaw and associated muscles and limitations in the ability to make the normal movements of speech, facial expression, eating, chewing, and swallowing. The conventional soft occlusal splint therapy is a much safer and effective mode of a conservative line of therapy in comparison to the surgical therapy for temporomandibular joint disorders (TMD). The purpose of this article is to review the Aqualizer™, an hydrostatic oral splint, as accurate, effective treatment and differential diagnostic tool in TMD that allow treating the patient's pain quickly and accurately saving valuable treatment time. The review article has been prepared doing a literature review from the world-wide web and pubmed/medline. PMID:24019797

  7. Ultrasensitive Wearable Soft Strain Sensors of Conductive, Self-healing, and Elastic Hydrogels with Synergistic "Soft and Hard" Hybrid Networks.

    PubMed

    Liu, Yan-Jun; Cao, Wen-Tao; Ma, Ming-Guo; Wan, Pengbo

    2017-08-02

    Robust, stretchable, and strain-sensitive hydrogels have recently attracted immense research interest because of their potential application in wearable strain sensors. The integration of the synergistic characteristics of decent mechanical properties, reliable self-healing capability, and high sensing sensitivity for fabricating conductive, elastic, self-healing, and strain-sensitive hydrogels is still a great challenge. Inspired by the mechanically excellent and self-healing biological soft tissues with hierarchical network structures, herein, functional network hydrogels are fabricated by the interconnection between a "soft" homogeneous polymer network and a "hard" dynamic ferric (Fe 3+ ) cross-linked cellulose nanocrystals (CNCs-Fe 3+ ) network. Under stress, the dynamic CNCs-Fe 3+ coordination bonds act as sacrificial bonds to efficiently dissipate energy, while the homogeneous polymer network leads to a smooth stress-transfer, which enables the hydrogels to achieve unusual mechanical properties, such as excellent mechanical strength, robust toughness, and stretchability, as well as good self-recovery property. The hydrogels demonstrate autonomously self-healing capability in only 5 min without the need of any stimuli or healing agents, ascribing to the reorganization of CNCs and Fe 3+ via ionic coordination. Furthermore, the resulted hydrogels display tunable electromechanical behavior with sensitive, stable, and repeatable variations in resistance upon mechanical deformations. Based on the tunable electromechanical behavior, the hydrogels can act as a wearable strain sensor to monitor finger joint motions, breathing, and even the slight blood pulse. This strategy of building synergistic "soft and hard" structures is successful to integrate the decent mechanical properties, reliable self-healing capability, and high sensing sensitivity together for assembling a high-performance, flexible, and wearable strain sensor.

  8. Enhanced Soft Tissue Attachment and Fixation Using a Mechanically-Stimulated Cytoselective Tissue-Specific ECM Coating

    DTIC Science & Technology

    2012-08-01

    currently used for surgical reinforcement for tendon rotator cuff repair . All scaffolds in this study were seeded using this protocol. PLA fabric...extracellular matrix scaffolds for rotator cuff tendon repair . Biomechanical, biochemical, and cellular properties. J Bone Joint Surg Am 2006;88(12):2665-72...mechanical stimulation of a co-cultured biomaterial scaffold can improve/expedite healing of a tendon-to-bone interface for soft tissue repair . There

  9. Performance Analysis of Diversity-Controlled Multi-User Superposition Transmission for 5G Wireless Networks

    PubMed Central

    Yeom, Jeong Seon; Jung, Bang Chul; Jin, Hu

    2018-01-01

    In this paper, we propose a novel low-complexity multi-user superposition transmission (MUST) technique for 5G downlink networks, which allows multiple cell-edge users to be multiplexed with a single cell-center user. We call the proposed technique diversity-controlled MUST technique since the cell-center user enjoys the frequency diversity effect via signal repetition over multiple orthogonal frequency division multiplexing (OFDM) sub-carriers. We assume that a base station is equipped with a single antenna but users are equipped with multiple antennas. In addition, we assume that the quadrature phase shift keying (QPSK) modulation is used for users. We mathematically analyze the bit error rate (BER) of both cell-edge users and cell-center users, which is the first theoretical result in the literature to the best of our knowledge. The mathematical analysis is validated through extensive link-level simulations. PMID:29439413

  10. [Topographological-anatomic changes in the structure of temporo-mandibular joint in case of fracture of the mandible condylar process at cervical level].

    PubMed

    Volkov, S I; Bazhenov, D V; Semkin, V A

    2011-01-01

    Pathological changes in soft tissues surrounding the fracture site as well as in the structural elements of temporo-mandibular joint always occured in condylar process fracture with shift at cervical mandibular jaw level. Other changes were also seen in the joint on the opposite normal side. Modelling of condylar process fracture at mandibular cervical level by means of three-dimensional computer model of temporo-mandibular joint contributed to proper understanding of this pathology emergence as well as to prediction and elimination of disorders arising in adjacent to the fracture site tissues.

  11. [Osseous and soft tissue operations for treatment of joint malpositioning in infantile cerebral palsy].

    PubMed

    Senst, S

    2013-12-01

    If untreated infantile cerebral palsy (ICP) leads to a progressive shortening of muscles and to progressive joint malpositioning. In addition a number of other disorders also result, in particular sensory disorders, intelligence deficits and epilepsy. In order to optimally treat as many as possible of the problems of multi-handicapped children with ICP it is of immanent importance that physiotherapists, occupational therapists, speech therapists, orthopedic technicians, pediatric orthopedists as well as neuropediatricians and social pediatricians work as a team. Surgical measures to correct joint malpositioning serve to improve the function and also to avoid or alleviate pain. Functional improvement measures are ideally undertaken during or shortly before elementary school age, thus enabling a further verticalization/straightening and mobilization. To improve symmetry and therefore the sitting posture, surgery is also indicated for profoundly disabled patients, sometimes making foot operations necessary. It is only in this way that maximum participation can be guaranteed and if necessary utilizing additional aids, such as Zimmer frames or E-wheelchairs.

  12. Fully Soft 3D-Printed Electroactive Fluidic Valve for Soft Hydraulic Robots.

    PubMed

    Zatopa, Alex; Walker, Steph; Menguc, Yigit

    2018-06-01

    Soft robots are designed to utilize their compliance and contortionistic abilities to both interact safely with their environment and move through it in ways a rigid robot cannot. To more completely achieve this, the robot should be made of as many soft components as possible. Here we present a completely soft hydraulic control valve consisting of a 3D-printed photopolymer body with electrorheological (ER) fluid as a working fluid and gallium-indium-tin liquid metal alloy as electrodes. This soft 3D-printed ER valve weighs less than 10 g and allows for onboard actuation control, furthering the goal of an entirely soft controllable robot. The soft ER valve pressure-holding capabilities were tested under unstrained conditions, cyclic valve activation, and the strained conditions of bending, twisting, stretching, and indentation. It was found that the max holding pressure of the valve when 5 kV was applied across the electrodes was 264 kPa, and that the holding pressure deviated less than 15% from the unstrained max holding pressure under all strain conditions except for indentation, which had a 60% max pressure increase. In addition, a soft octopus-like robot was designed, 3D printed, and assembled, and a soft ER valve was used to stop the fluid flow, build pressure in the robot, and actuate six tentacle-like soft bending actuators.

  13. 'Putting it on the table': direct-manipulative interaction and multi-user display technologies for semi-immersive environments and augmented reality applications.

    PubMed

    Encarnação, L Miguel; Bimber, Oliver

    2002-01-01

    Collaborative virtual environments for diagnosis and treatment planning are increasingly gaining importance in our global society. Virtual and Augmented Reality approaches promised to provide valuable means for the involved interactive data analysis, but the underlying technologies still create a cumbersome work environment that is inadequate for clinical employment. This paper addresses two of the shortcomings of such technology: Intuitive interaction with multi-dimensional data in immersive and semi-immersive environments as well as stereoscopic multi-user displays combining the advantages of Virtual and Augmented Reality technology.

  14. Cascaded neural networks for sequenced propagation estimation, multiuser detection, and adaptive radio resource control of third-generation wireless networks for multimedia services

    NASA Astrophysics Data System (ADS)

    Hortos, William S.

    1999-03-01

    A hybrid neural network approach is presented to estimate radio propagation characteristics and multiuser interference and to evaluate their combined impact on throughput, latency and information loss in third-generation (3G) wireless networks. The latter three performance parameters influence the quality of service (QoS) for multimedia services under consideration for 3G networks. These networks, based on a hierarchical architecture of overlaying macrocells on top of micro- and picocells, are planned to operate in mobile urban and indoor environments with service demands emanating from circuit-switched, packet-switched and satellite-based traffic sources. Candidate radio interfaces for these networks employ a form of wideband CDMA in 5-MHz and wider-bandwidth channels, with possible asynchronous operation of the mobile subscribers. The proposed neural network (NN) architecture allocates network resources to optimize QoS metrics. Parameters of the radio propagation channel are estimated, followed by control of an adaptive antenna array at the base station to minimize interference, and then joint multiuser detection is performed at the base station receiver. These adaptive processing stages are implemented as a sequence of NN techniques that provide their estimates as inputs to a final- stage Kohonen self-organizing feature map (SOFM). The SOFM optimizes the allocation of available network resources to satisfy QoS requirements for variable-rate voice, data and video services. As the first stage of the sequence, a modified feed-forward multilayer perceptron NN is trained on the pilot signals of the mobile subscribers to estimate the parameters of shadowing, multipath fading and delays on the uplinks. A recurrent NN (RNN) forms the second stage to control base stations' adaptive antenna arrays to minimize intra-cell interference. The third stage is based on a Hopfield NN (HNN), modified to detect multiple users on the uplink radio channels to mitigate multiaccess

  15. Soft buckling actuators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dian; Whitesides, George M.

    A soft actuator is described, including: a rotation center having a center of mass; a plurality of bucklable, elastic structural components each comprising a wall defining an axis along its longest dimension, the wall connected to the rotation center in a way that the axis is offset from the center of mass in a predetermined direction; and a plurality of cells each disposed between two adjacent bucklable, elastic structural components and configured for connection with a fluid inflation or deflation source; wherein upon the deflation of the cell, the bucklable, elastic structural components are configured to buckle in the predeterminedmore » direction. A soft actuating device including a plurality of the soft actuators and methods of actuation using the soft actuator or soft actuating device disclosed herein are also described.« less

  16. [Joint dislocation after total knee arthroplasty as an ankle fracture complication. Case report].

    PubMed

    Hrubina, M; Skoták, M

    2012-01-01

    Joint dislocation after total knee arthroplasty is a rare complication. It is described as the result of ligamentous instability. Here we report the case of an 82-year-old women who underwent primary total knee arthroplasty (TKA) for advanced primary grade III gonarthrosis. At 3 post-operative months the joint was stable and painless, with radiographic evidence of good TKA alignment and integration. At 4 months the patient suffered injury to the ankle involving a bimalleolar fracture and damage to knee soft tissues. The fracture was surgically treated. Subsequently, dorsal tibial dislocation was manifested. This was managed by individual intramedullary nail arthrodesis. At 8 months following the operation, the knee condition was satisfactory, with rigid arthrodesis and leg shortening of 4 cm. The patient was satisfied because she was free of pain and able to walk. Arthrodesis of the knee joint with an individual nail is an option for a definitive treatment of TKA instability. When other joints, such as ankle or hip joints, are injured, it is recommended to pay attention also to any TKA implanted previously because of potential development of instability or infection.

  17. Effect of Soft Tissue Releases on Joint Space Opening in Total Knee Arthroplasty.

    PubMed

    Burkhart, Timothy A; Perry, Kevin I; Dobbin, Emily; Howard, James; Lanting, Brent

    2016-12-01

    The purpose of this study was to determine the gap achieved to the medial and lateral compartments following sectioning and release of the relevant soft tissues in preparation for a total knee arthroplasty. A custom-designed knee tensioner allowed the application of forces to the medial and lateral compartments of 12 cadaveric knee specimens. Loads of 100 N and 200 N were applied to each compartment, and the resulting displacement was measured in the following conditions: (1) All soft tissues intact, (2) an arthrotomy, (3) anterior cruciate ligament (ACL) sectioned, (4) posterior cruciate ligament (PCL) sectioned, and (5) release of the anterior aspect of the deep medial collateral ligament (MCL) fibers. Tensions were applied for all conditions from 90° to 0° of knee flexion in 30° increments. No differences were found in medial or lateral displacement after the arthrotomy or releasing the ACL or PCL at either 100 N or 200 N. At the 100 N load application, there was a significant increase in gap width when the anterior portion of the deep MCL was released (7.49 mm) compared to the intact (5.28 mm) and arthrotomy (5.75 mm) conditions. With respect to the 200 N load application, there were statistically significant differences detected between the deep MCL fiber release (11.09 mm) and intact conditions (8.05 mm) and release of the deep MCL and arthrotomy conditions (8.77 mm). The medial parapetellar arthrotomy, ACL and PCL sectioning did not result in medial or lateral displacement changes. The release of the anterior fibers of the deep MCL as part of the surgical exposure increased the medial gap magnitude. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Heavy-tailed distribution of the SSH Brute-force attack duration in a multi-user environment

    NASA Astrophysics Data System (ADS)

    Lee, Jae-Kook; Kim, Sung-Jun; Park, Chan Yeol; Hong, Taeyoung; Chae, Huiseung

    2016-07-01

    Quite a number of cyber-attacks to be place against supercomputers that provide highperformance computing (HPC) services to public researcher. Particularly, although the secure shell protocol (SSH) brute-force attack is one of the traditional attack methods, it is still being used. Because stealth attacks that feign regular access may occur, they are even harder to detect. In this paper, we introduce methods to detect SSH brute-force attacks by analyzing the server's unsuccessful access logs and the firewall's drop events in a multi-user environment. Then, we analyze the durations of the SSH brute-force attacks that are detected by applying these methods. The results of an analysis of about 10 thousands attack source IP addresses show that the behaviors of abnormal users using SSH brute-force attacks are based on human dynamic characteristics of a typical heavy-tailed distribution.

  19. Extreme Mechanics in Soft Pneumatic Robots and Soft Microfluidic Electronics and Sensors

    NASA Astrophysics Data System (ADS)

    Majidi, Carmel

    2012-02-01

    In the near future, machines and robots will be completely soft, stretchable, impact resistance, and capable of adapting their shape and functionality to changes in mission and environment. Similar to biological tissue and soft-body organisms, these next-generation technologies will contain no rigid parts and instead be composed entirely of soft elastomers, gels, fluids, and other non-rigid matter. Using a combination of rapid prototyping tools, microfabrication methods, and emerging techniques in so-called ``soft lithography,'' scientists and engineers are currently introducing exciting new families of soft pneumatic robots, soft microfluidic sensors, and hyperelastic electronics that can be stretched to as much as 10x their natural length. Progress has been guided by an interdisciplinary collection of insights from chemistry, life sciences, robotics, microelectronics, and solid mechanics. In virtually every technology and application domain, mechanics and elasticity have a central role in governing functionality and design. Moreover, in contrast to conventional machines and electronics, soft pneumatic systems and microfluidics typically operate in the finite deformation regime, with materials stretching to several times their natural length. In this talk, I will review emerging paradigms in soft pneumatic robotics and soft microfluidic electronics and highlight modeling and design challenges that arise from the extreme mechanics of inflation, locomotion, sensor operation, and human interaction. I will also discuss perceived challenges and opportunities in a broad range of potential application, from medicine to wearable computing.

  20. Rationale, principles and experimental evaluation of the concept of soft stabilization.

    PubMed

    Mulholland, Robert C; Sengupta, Dilip K

    2002-10-01

    The apparent clinical success of spinal stabilization methods that restrict rather than abolish movement in relieving mechanical back pain indicates that the concept of the aetiology of back pain should be reviewed. Further understanding of how degeneration affects disc biomechanics, and an understanding of how current soft stabilization systems alters them, may allow us to define more precisely what are the essential requirements of an ideal soft stabilization system. It appears that abnormal patterns of loading rather than abnormal movement are the reason that disc degeneration causes back pain in some patients. Abnormal load transmission is the principal cause of pain in osteoarthritic joints, and both osteotomy and, indeed, joint replacement succeed because they alter the load transmission across the joint. This concept is supported by the fact that abnormal patterns of stress distribution measured across the disc correlate with painful discs on discography. Clinically, it is often noted that back pain is primarily related to position or posture, rather than movement of the lumbar spine. Clinical success after solid fusion is unpredictable because it does not necessarily prevent painful loading across the disc, and also it may interfere with maintenance of sagittal balance in varying postures. The Graf ligament restricted flexion, and was modestly successful. It unfortunately increased the load over the posterior annulus. The Dynesys system reduces movement both in flexion and extension, and appears to be more successful. However, often it also unloads the disc to a degree that is unpredictable. The authors believe that this unloading of the disc is an important feature of a flexible stabilization system. A new a design of a flexible stabilization system has recently been described in an in vitro study, which unloads the disc by introduction of a load-sharing fulcrum near the axis of movement together with an elastic posterior ligament. This design produces

  1. [Skin and soft tissue complications after orthopedic interventions on tumors : interdisciplinary management].

    PubMed

    Radtke, C; Calliess, T; Windhagen, H; Vogt, P

    2015-03-01

    Interdisciplinary collaboration between orthopedic and plastic surgeons is indicated in reconstructive surgery of the extremities for both traumatic orthopedic fractures with extensive soft tissue damage and musculoskeletal tumor resection. We want to emphasize the need for close cooperation starting in the preoperative planning for reconstruction after tumor resection in order to discuss and establish a unified approach. This is particularly important to establish a joint approach with special consideration of possibly necessary adjuvant therapies. One collaborative approach is for the orthopedic surgeon to resect the tumor and the plastic surgeon to carry out the defect reconstruction for exclusive soft tissue coverage including flap surgery as well as for functional reconstruction depending on the location and extent of tumor resection. Thus, careful preoperative and postoperative communication on the precise location, extent of tumor resection and the therapy timing between the orthopedic surgeon and the plastic surgeon will allow the most effective subsequent repair of the resection site.

  2. Mechanical model of suture joints with fibrous connective layer

    NASA Astrophysics Data System (ADS)

    Miroshnichenko, Kateryna; Liu, Lei; Tsukrov, Igor; Li, Yaning

    2018-02-01

    A composite model for suture joints with a connective layer of aligned fibers embedded in soft matrix is proposed. Based on the principle of complementary virtual work, composite cylinder assemblage (CCA) approach and generalized self-consistent micro-mechanical models, a hierarchical homogenization methodology is developed to systematically quantify the synergistic effects of suture morphology and fiber orientation on the overall mechanical properties of sutures. Suture joints with regular triangular wave-form serve as an example material system to apply this methodology. Both theoretical and finite element mechanical models are developed and compared to evaluate the overall normal stiffness of sutures as a function of wavy morphology of sutures, fiber orientation, fiber volume fraction, and the mechanical properties of fibers and matrix in the interfacial layer. It is found that generally due to the anisotropy-induced coupling effects between tensile and shear deformation, the effective normal stiffness of sutures is highly dependent on the fiber orientation in the connective layer. Also, the effective shear modulus of the connective layer and the stiffness ratio between the fiber and matrix significantly influence the effects of fiber orientation. In addition, optimal fiber orientations are found to maximize the stiffness of suture joints.

  3. Effect of Retrograde Reaming for Tibiotalocalcaneal Arthrodesis on Subtalar Joint Destruction: A Cadaveric Study.

    PubMed

    Lowe, Jason A; Routh, Lucas K; Leary, Jeffrey T; Buzhardt, Paul C

    2016-01-01

    Recent published data have suggested successful union of subtalar and tibiotalar joints without formal debridement during tibiotalocalcaneal (TTC) fusion procedures. Although previous studies have reported on the importance of the proper guidewire starting point and trajectory to obtain appropriate hindfoot alignment for successful fusion, to our knowledge, no studies have quantified the amount of articular damage to the subtalar joint with retrograde reaming. We hypothesized that reaming would destroy >50% of the posterior facet of the subtalar joint. The bilateral lower extremities of 5 cadavers were obtained and the subtalar joints exposed. Retrograde TTC nail guidewires were inserted, and a 12-mm reamer was passed through the subtalar and ankle joints. Pre- and postreaming images of the subtalar joint were obtained to compare the amount of joint destruction after reaming. We found an average of 5.89% articular destruction of the talar posterior facet and an average of 4.01% articular destruction of the posterior facet of the calcaneus. No damage to the middle facets of the subtalar joint was observed. TTC nailing is a successful procedure for ankle and subtalar joint fusion. Published studies have reported successful subtalar union using TTC nailing without formal open debridement of the subtalar joint, preserving the soft tissue envelope. TTC nail insertion using a 12-mm reamer will destroy 5.89% and 4.01% of the respective talar and calcaneal posterior facets of the subtalar joint. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Interphalangeal joint involvement of the big toe in gout: a rare presentation.

    PubMed

    Dobson, Michael; Alwahab, Yasir; Fazal, Muhammad A

    2012-01-01

    Atypical presentation of gout can cause diagnostic dilemmas. We report a case of gout that presented with an expansile lytic lesion involving the interphalangeal joint of the hallux, lack of a history of gout, and an associated solitary lung nodule. Magnetic resonance imaging showed an expansile destructive bony lesion with soft-tissue involvement suggestive of a possible bony metastasis. A needle biopsy was performed, and histopathologic features were diagnostic of chronic tophaceous gout.

  5. Interaction Design and Usability of Learning Spaces in 3D Multi-user Virtual Worlds

    NASA Astrophysics Data System (ADS)

    Minocha, Shailey; Reeves, Ahmad John

    Three-dimensional virtual worlds are multimedia, simulated environments, often managed over the Web, which users can 'inhabit' and interact via their own graphical, self-representations known as 'avatars'. 3D virtual worlds are being used in many applications: education/training, gaming, social networking, marketing and commerce. Second Life is the most widely used 3D virtual world in education. However, problems associated with usability, navigation and way finding in 3D virtual worlds may impact on student learning and engagement. Based on empirical investigations of learning spaces in Second Life, this paper presents design guidelines to improve the usability and ease of navigation in 3D spaces. Methods of data collection include semi-structured interviews with Second Life students, educators and designers. The findings have revealed that design principles from the fields of urban planning, Human- Computer Interaction, Web usability, geography and psychology can influence the design of spaces in 3D multi-user virtual environments.

  6. Development and experimental validation of downlink multiuser MIMO-OFDM in gigabit wireless LAN systems

    NASA Astrophysics Data System (ADS)

    Ishihara, Koichi; Asai, Yusuke; Kudo, Riichi; Ichikawa, Takeo; Takatori, Yasushi; Mizoguchi, Masato

    2013-12-01

    Multiuser multiple-input multiple-output (MU-MIMO) has been proposed as a means to improve spectrum efficiency for various future wireless communication systems. This paper reports indoor experimental results obtained for a newly developed and implemented downlink (DL) MU-MIMO orthogonal frequency division multiplexing (OFDM) transceiver for gigabit wireless local area network systems in the microwave band. In the transceiver, the channel state information (CSI) is estimated at each user and fed back to an access point (AP) on a real-time basis. At the AP, the estimated CSI is used to calculate the transmit beamforming weight for DL MU-MIMO transmission. This paper also proposes a recursive inverse matrix computation scheme for computing the transmit weight in real time. Experiments with the developed transceiver demonstrate its feasibility in a number of indoor scenarios. The experimental results clarify that DL MU-MIMO-OFDM transmission can achieve a 972-Mbit/s transmission data rate with simple digital signal processing of single-antenna users in an indoor environment.

  7. A power-efficient ZF precoding scheme for multi-user indoor visible light communication systems

    NASA Astrophysics Data System (ADS)

    Zhao, Qiong; Fan, Yangyu; Deng, Lijun; Kang, Bochao

    2017-02-01

    In this study, we propose a power-efficient ZF precoding scheme for visible light communication (VLC) downlink multi-user multiple-input-single-output (MU-MISO) systems, which incorporates the zero-forcing (ZF) and the characteristics of VLC systems. The main idea of this scheme is that the channel matrix used to perform pseudoinverse comes from the set of optical Access Points (APs) shared by more than one user, instead of the set of all involved serving APs as the existing ZF precoding schemes often used. By doing this, the waste of power, which is caused by the transmission of one user's data in the un-serving APs, can be avoided. In addition, the size of the channel matrix needs to perform pseudoinverse becomes smaller, which helps to reduce the computation complexity. Simulation results in two scenarios show that the proposed ZF precoding scheme has higher power efficiency, better bit error rate (BER) performance and lower computation complexity compared with traditional ZF precoding schemes.

  8. Photoacoustic imaging of inflammatory arthritis in human joints

    NASA Astrophysics Data System (ADS)

    Jo, Janggun; Xu, Guan; Marquardt, April; Francis, Sheeja; Yuan, Jie; Girish, Dhanuj; Girish, Gandikota; Wang, Xueding

    2016-02-01

    The ducal imaging with photoacoustic imaging (PAI) that is an emerging technology and clinical ultrasound imaging that is an established modality is developed for the imaging of early inflammatory arthritis. PAI is sensitive to blood volume, not limited by flow like ultrasound, holding great promise for the earliest detection of increase in blood volume and angiogenesis - a key early finding inflammation PAI has the capability of assessing inflammation in superficial human soft tissues, offering potential benefits in diagnosis, treatment and monitoring of inflammatory arthritis. PAI combined with ultrasonography (US), is a real time dual-modality system developed and tested to identify active synovitis in metacarpophalangeal (MCP) joints of 10 arthritis patients and 10 normal volunteers. Photoacoustic images of the joints were acquired at 580-nm laser wavelength, which provided the desired balance between the optical contrast of hemoglobin over bone cortex and the imaging depth. Confirmed by US Doppler imaging, the results from ten patients and ten normal volunteers demonstrated satisfactory sensitivity of PAI in assessing enhanced blood flow due to active synovitis. This preliminary study suggests that photoacoustic imaging, by identifying early increase in blood volume, related to increased vascularity, a hallmark of joint inflammation, could be a valuable supplement to musculoskeletal US.

  9. Joint SSRTNet/ALS-MES Workshop report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shuh, David; Van Hove, Michel

    2001-11-30

    This joint workshop brought together experimentalists and theorists interested in synchrotron radiation and highlighted subjects relevant to molecular environmental science (MES). The strong mutual interest between the participants resulted in joint sessions on the first day, followed by more specialized parallel sessions on the second day. Held in conjunction with the Advanced Light Source (ALS) Users' Association Annual Meeting at the Lawrence Berkeley National Laboratory (Berkeley Lab), the Synchrotron Radiation Research Theory Network (SRRTNet) workshop was co-organized by Michel Van Hove (Berkeley Lab and University of California, Davis) and Andrew Canning (Berkeley Lab), while David Shuh (Berkeley Lab) organized themore » ALS-MES workshop. SRRTNet is a global network that promotes the interaction of theory and experiment (http://www.cse.clrc.ac.uk/Activity/SRRTnet). The ALS-MES project is constructing Beamline 11.0.2.1-2, a new soft x-ray beamline for MES investigations at photon energies from 75 eV to 2 keV, to provide photons for wet spectroscopy end stations and an upgraded scanning transmission x-ray microscope (STXM). The ALS-MES beamline and end stations will be available for users in the late fall of 2002.« less

  10. Biomechanical study of tarsometatarsal joint fusion using finite element analysis.

    PubMed

    Wang, Yan; Li, Zengyong; Zhang, Ming

    2014-11-01

    Complications of surgeries in foot and ankle bring patients with severe sufferings. Sufficient understanding of the internal biomechanical information such as stress distribution, contact pressure, and deformation is critical to estimate the effectiveness of surgical treatments and avoid complications. Foot and ankle is an intricate and synergetic system, and localized intervention may alter the functions to the adjacent components. The aim of this study was to estimate biomechanical effects of the TMT joint fusion using comprehensive finite element (FE) analysis. A foot and ankle model consists of 28 bones, 72 ligaments, and plantar fascia with soft tissues embracing all the segments. Kinematic information and ground reaction force during gait were obtained from motion analysis. Three gait instants namely the first peak, second peak and mid-stance were simulated in a normal foot and a foot with TMT joint fusion. It was found that contact pressure on plantar foot increased by 0.42%, 19% and 37%, respectively after TMT fusion compared with normal foot walking. Navico-cuneiform and fifth meta-cuboid joints sustained 27% and 40% increase in contact pressure at second peak, implying potential risk of joint problems such as arthritis. Von Mises stress in the second metatarsal bone increased by 22% at midstance, making it susceptible to stress fracture. This study provides biomechanical information for understanding the possible consequences of TMT joint fusion. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. A study of cervical spine kinematics and joint capsule strain in rear impacts using a human FE model.

    PubMed

    Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji

    2006-11-01

    Many efforts have been made to understand the mechanism of whiplash injury. Recently, the cervical facet joint capsules have been focused on as a potential site of injury. An experimental approach has been taken to analyze the vertebral motion and to estimate joint capsule stretch that was thought to be a potential cause of pain. The purpose of this study is to analyze the kinematics of the cervical facet joint using a human FE model in order to better understand the injury mechanism. The Total Human Model for Safety (THUMS) was used to visually analyze the local and global kinematics of the spine. Soft tissues in the neck were newly modeled and introduced into THUMS for estimating the loading level in rear impacts. The model was first validated against human test data in the literature by comparing vertebrae motion as well as head and neck responses. Joint capsule strain was estimated from a maximum principal strain output from the elements representing the capsule tissues. A rear-end collision was then simulated using THUMS and a prototype seat model, assuming a delta-V of 25 km/h. The trajectory of the vertebrae was analyzed in a local coordinate system defined along the joint surface. Strain growth in the joint capsules was explained, as related to contact events between the occupant and the seat. A new seat concept was proposed to help lessen the loading level to the neck soft tissues. The foam material of the seat back was softened, the initial gap behind the head was reduced and the head restraint was stiffened for firm support. The lower seat back frame was also reinforced to withstand the impact severity at the given delta-V. Another rear impact simulation was conducted using the new seat concept model to examine the effectiveness of the new concept. The joint capsule strain was found to be relatively lower with the new seat concept. The study also discusses the influence of seat parameters to the vertebral motion and the resultant strain in the joint

  12. FEANICS: A Multi-User Facility For Conducting Solid Fuel Combustion Experiments On ISS

    NASA Technical Reports Server (NTRS)

    Frate, David T.; Tofil, Todd A.

    2001-01-01

    The Destiny Module on the International Space Station (ISS) will soon be home for the Fluids and Combustion Facility's (FCF) Combustion Integrated Rack (CIR), which is being developed at the NASA Glenn Research Center in Cleveland, Ohio. The CIR will be the platform for future microgravity combustion experiments. A multi-user mini-facility called FEANICS (Flow Enclosure Accommodating Novel Investigations in Combustion of Solids) will also be built at NASA Glenn. This mini-facility will be the primary means for conducting solid fuel combustion experiments in the CIR on ISS. The main focus of many of these solid combustion experiments will be to conduct basic and applied scientific investigations in fire-safety to support NASA's Bioastronautics Initiative. The FEANICS project team will work in conjunction with the CIR project team to develop upgradeable and reusable hardware to meet the science requirements of current and future investigators. Currently, there are six experiments that are candidates to use the FEANICS mini-facility. This paper will describe the capabilities of this mini-facility and the type of solid combustion testing and diagnostics that can be performed.

  13. Soft Pion Processes

    DOE R&D Accomplishments Database

    Nambu, Y.

    1968-01-01

    My talk is concerned with a review, not necessarily of the latest theoretical developments, but rather of an old idea which has contributed to recent theoretical activities. By soft pion processes I mean processes in which low energy pions are emitted or absorbed or scattered, just as we use the word soft photon in a similar context. Speaking more quantitatively, we may call a pion soft if its energy is small compared to a natural scale in the reaction. This scale is determined by the particular dynamics of pion interaction, and one may roughly say that a pion is soft if its energy is small compared to the energies of the other individual particles that participate in the reaction. It is important to note at this point that pion is by far the lightest member of all the hadrons, and much of the success of the soft pion formulas depends on this fact.

  14. Necrotizing soft tissue infection

    MedlinePlus

    Necrotizing fasciitis; Fasciitis - necrotizing; Flesh-eating bacteria; Soft tissue gangrene; Gangrene - soft tissue ... Many different types of bacteria can cause this infection. A very severe and usually deadly form of necrotizing soft tissue infection is due to the ...

  15. Repositioning the knee joint in human body FE models using a graphics-based technique.

    PubMed

    Jani, Dhaval; Chawla, Anoop; Mukherjee, Sudipto; Goyal, Rahul; Vusirikala, Nataraju; Jayaraman, Suresh

    2012-01-01

    Human body finite element models (FE-HBMs) are available in standard occupant or pedestrian postures. There is a need to have FE-HBMs in the same posture as a crash victim or to be configured in varying postures. Developing FE models for all possible positions is not practically viable. The current work aims at obtaining a posture-specific human lower extremity model by reconfiguring an existing one. A graphics-based technique was developed to reposition the lower extremity of an FE-HBM by specifying the flexion-extension angle. Elements of the model were segregated into rigid (bones) and deformable components (soft tissues). The bones were rotated about the flexion-extension axis followed by rotation about the longitudinal axis to capture the twisting of the tibia. The desired knee joint movement was thus achieved. Geometric heuristics were then used to reposition the skin. A mapping defined over the space between bones and the skin was used to regenerate the soft tissues. Mesh smoothing was then done to augment mesh quality. The developed method permits control over the kinematics of the joint and maintains the initial mesh quality of the model. For some critical areas (in the joint vicinity) where element distortion is large, mesh smoothing is done to improve mesh quality. A method to reposition the knee joint of a human body FE model was developed. Repositions of a model from 9 degrees of flexion to 90 degrees of flexion in just a few seconds without subjective interventions was demonstrated. Because the mesh quality of the repositioned model was maintained to a predefined level (typically to the level of a well-made model in the initial configuration), the model was suitable for subsequent simulations.

  16. Sea urchin puncture resulting in PIP joint synovial arthritis: case report and MRI study.

    PubMed

    Liram, N; Gomori, M; Perouansky, M

    2000-01-01

    Of the 600 species of sea urchins, approximately 80 may be venomous to humans. The long spined or black sea urchin, Diadema setosum may cause damage by the breaking off of its brittle spines after they penetrate the skin. Synovitis followed by arthritis may be an unusual but apparently not a rare sequel to such injury, when implantation occurs near a joint. In this case report, osseous changes were not seen by plain x-rays. Magnetic resonance imaging (MRI) was used to expose the more salient features of both soft tissue and bone changes of black sea urchin puncture injury 30 months after penetration. In all likelihood, this type of injury may be more common than the existing literature at present suggests. It is believed to be the first reported case in this part of the world as well as the first MRI study describing this type of joint pathology. Local and systemic reactions to puncture injuries from sea urchin spines have been described previously. These may range from mild, local irritation lasting a few days to granuloma formation, infection and on occasions systemic illness. The sea urchin spines are composed of calcium carbonate with proteinaceous covering. The covering tends to cause immune reactions of variable presentation. There are only a handful of reported cases with sea urchin stings on record, none of them from the Red Sea. However, this condition is probably more common than is thought and can present difficulty in diagnosis. In this case report, the inflammation responded well to heat treatment, mobilization and manipulation of the joint in its post acute and chronic stages. As some subtle changes in soft tissues and the changes in bone were not seen either on plain x-rays or ultrasound scan, gadolinium-enhanced MRI was used to unveil the marked changes in the joint.

  17. Ductile fracture mechanism of low-temperature In-48Sn alloy joint under high strain rate loading.

    PubMed

    Kim, Jong-Woong; Jung, Seung-Boo

    2012-04-01

    The failure behaviors of In-48Sn solder ball joints under various strain rate loadings were investigated with both experimental and finite element modeling study. The bonding force of In-48Sn solder on an Ni plated Cu pad increased with increasing shear speed, mainly due to the high strain-rate sensitivity of the solder alloy. In contrast to the cases of Sn-based Pb-free solder joints, the transition of the fracture mode from a ductile mode to a brittle mode was not observed in this solder joint system due to the soft nature of the In-48Sn alloy. This result is discussed in terms of the relationship between the strain-rate of the solder alloy, the work-hardening effect and the resulting stress concentration at the interfacial regions.

  18. Knee joint transplantation combined with surgical angiogenesis in rabbits – a new experimental model

    PubMed Central

    Kremer, Thomas; Giusti, Guilherme; Friedrich, Patricia F.; Willems, Wouter; Bishop, Allen T.; Giessler, Goetz A.

    2012-01-01

    Summary Purpose We have previously described a means to maintain bone allotransplant viability, without long-term immune modulation, replacing allogenic bone vasculature with autogenous vessels. A rabbit model for whole knee joint transplantation was developed and tested using the same methodology, initially as an autotransplant. Materials/Methods Eight New Zealand White rabbit knee joints were elevated on a popliteal vessel pedicle to evaluate limb viability in a non-survival study. Ten additional joints were elevated and replaced orthotopically in a fashion identical to allotransplantation, obviating only microsurgical repairs and immunosuppression. A superficial inferior epigastric facial (SIEF) flap and a saphenous arteriovenous (AV) bundle were introduced into the femur and tibia respectively, generating a neoangiogenic bone circulation. In allogenic transplantation, this step maintains viability after cessation of immunosuppression. Sixteen weeks later, x-rays, microangiography, histology, histomorphometry and biomechanical analysis were performed. Results Limb viability was preserved in the initial 8 animals. Both soft tissue and bone healing occurred in 10 orthotopic transplants. Surgical angiogenesis from the SIEF flap and AV bundle was always present. Bone and joint viability was maintained, with demonstrable new bone formation. Bone strength was less than the opposite side. Arthrosis and joint contractures were frequent. Conclusion We have developed a rabbit knee joint model and evaluation methods suitable for subsequent studies of whole joint allotransplantation. PMID:22113889

  19. Biomedical applications of soft robotics

    NASA Astrophysics Data System (ADS)

    Cianchetti, Matteo; Laschi, Cecilia; Menciassi, Arianna; Dario, Paolo

    2018-06-01

    Soft robotics enables the design of soft machines and devices at different scales. The compliance and mechanical properties of soft robots make them especially interesting for medical applications. Depending on the level of interaction with humans, different levels of biocompatibility and biomimicry are required for soft materials used in robots. In this Review, we investigate soft robots for biomedical applications, including soft tools for surgery, diagnosis and drug delivery, wearable and assistive devices, prostheses, artificial organs and tissue-mimicking active simulators for training and biomechanical studies. We highlight challenges regarding durability and reliability, and examine traditional and novel soft and active materials as well as different actuation strategies. Finally, we discuss future approaches and applications in the field.

  20. SoftLab: A Soft-Computing Software for Experimental Research with Commercialization Aspects

    NASA Technical Reports Server (NTRS)

    Akbarzadeh-T, M.-R.; Shaikh, T. S.; Ren, J.; Hubbell, Rob; Kumbla, K. K.; Jamshidi, M

    1998-01-01

    SoftLab is a software environment for research and development in intelligent modeling/control using soft-computing paradigms such as fuzzy logic, neural networks, genetic algorithms, and genetic programs. SoftLab addresses the inadequacies of the existing soft-computing software by supporting comprehensive multidisciplinary functionalities from management tools to engineering systems. Furthermore, the built-in features help the user process/analyze information more efficiently by a friendly yet powerful interface, and will allow the user to specify user-specific processing modules, hence adding to the standard configuration of the software environment.

  1. Phenomena of nonlinear oscillation and special resonance of a dielectric elastomer minimum energy structure rotary joint

    NASA Astrophysics Data System (ADS)

    Zhao, Jianwen; Niu, Junyang; McCoul, David; Ren, Zhi; Pei, Qibing

    2015-03-01

    The dielectric elastomer minimum energy structure can realize large angular deformations by a small voltage-induced strain of the dielectric elastomer, so it is a suitable candidate to make a rotary joint for a soft robot. Driven with an alternating electric field, the joint deformation vibrational frequency follows the input voltage frequency. However, the authors find that if the rotational inertia increases such that the inertial torque makes the frame deform over a negative angle, then the joint motion will become complicated and the vibrational mode will alter with the change of voltage frequency. The vibration with the largest amplitude does not occur while the voltage frequency is equal to natural response frequency of the joint. Rather, the vibrational amplitude will be quite large over a range of other frequencies at which the vibrational frequency is half of the voltage frequency. This phenomenon was analyzed by a comparison of the timing sequences between voltage and joint vibration. This vibrational mode with the largest amplitude can be applied to the generation lift in a flapping wing actuated by dielectric elastomers.

  2. Histology and imaging of soft tissue sarcomas.

    PubMed

    Kind, Michèle; Stock, Nathalie; Coindre, Jean Michel

    2009-10-01

    Imaging and histology are two complementary morphological techniques which play a fundamental role in the diagnosis and management of soft tissue sarcomas. Imaging allows to identify some pseudosarcomatous benign lesions such as myositis ossificans, intramuscular hemangioma, angiomyolipoma, intramuscular lipoma, giant cell tumour of tendon sheath, desmoid tumour and elastofibroma. There is no formal criterion for diagnosing a sarcoma on magnetic resonance imaging (MRI) but malignancy is strongly suspected with the presence of necrosis and vascular, bone or joint invasion. Imaging may also suggest some histological types of sarcoma such as well-differentiated liposarcoma, dedifferentiated liposarcoma, synovial sarcoma or extraskeletal osteosarcoma. Imaging is also extremely helpful in determining the appropriate kind of sampling to carry out and in guiding the performance of a microbiopsy. The appearance observed on imaging should always be taken into consideration for the interpretation of the microbiopsy by the pathologist.

  3. SOFT ROBOTICS. A 3D-printed, functionally graded soft robot powered by combustion.

    PubMed

    Bartlett, Nicholas W; Tolley, Michael T; Overvelde, Johannes T B; Weaver, James C; Mosadegh, Bobak; Bertoldi, Katia; Whitesides, George M; Wood, Robert J

    2015-07-10

    Roboticists have begun to design biologically inspired robots with soft or partially soft bodies, which have the potential to be more robust and adaptable, and safer for human interaction, than traditional rigid robots. However, key challenges in the design and manufacture of soft robots include the complex fabrication processes and the interfacing of soft and rigid components. We used multimaterial three-dimensional (3D) printing to manufacture a combustion-powered robot whose body transitions from a rigid core to a soft exterior. This stiffness gradient, spanning three orders of magnitude in modulus, enables reliable interfacing between rigid driving components (controller, battery, etc.) and the primarily soft body, and also enhances performance. Powered by the combustion of butane and oxygen, this robot is able to perform untethered jumping. Copyright © 2015, American Association for the Advancement of Science.

  4. Quantifying in vivo laxity in the anterior cruciate ligament and individual knee joint structures.

    PubMed

    Westover, L M; Sinaei, N; Küpper, J C; Ronsky, J L

    2016-11-01

    A custom knee loading apparatus (KLA), when used in conjunction with magnetic resonance imaging, enables in vivo measurement of the gross anterior laxity of the knee joint. A numerical model was applied to the KLA to understand the contribution of the individual joint structures and to estimate the stiffness of the anterior-cruciate ligament (ACL). The model was evaluated with a cadaveric study using an in situ knee loading apparatus and an ElectroForce test system. A constrained optimization solution technique was able to predict the restraining forces within the soft-tissue structures and joint contact. The numerical model presented here allowed in vivo prediction of the material stiffness parameters of the ACL in response to applied anterior loading. Promising results were obtained for in vivo load sharing within the structures. The numerical model overestimated the ACL forces by 27.61-92.71%. This study presents a novel approach to estimate ligament stiffness and provides the basis to develop a robust and accurate measure of in vivo knee joint laxity.

  5. The Effect of the Use of the 3-D Multi-User Virtual Environment "Second Life" on Student Motivation and Language Proficiency in Courses of Spanish as a Foreign Language

    ERIC Educational Resources Information Center

    Pares-Toral, Maria T.

    2013-01-01

    The ever increasing popularity of virtual worlds, also known as 3-D multi-user virtual environments (MUVEs) or simply virtual worlds provides language instructors with a new tool they can exploit in their courses. For now, "Second Life" is one of the most popular MUVEs used for teaching and learning, and although "Second Life"…

  6. Geometry and Material Constraint Effects on Creep Crack Growth Behavior in Welded Joints

    NASA Astrophysics Data System (ADS)

    Li, Y.; Wang, G. Z.; Xuan, F. Z.; Tu, S. T.

    2017-02-01

    In this work, the geometry and material constraint effects on creep crack growth (CCG) and behavior in welded joints were investigated. The CCG paths and rates of two kinds of specimen geometry (C(T) and M(T)) with initial cracks located at soft HAZ (heat-affected zone with lower creep strength) and different material mismatches were simulated. The effect of constraint on creep crack initiation (CCI) time was discussed. The results show that there exists interaction between geometry and material constraints in terms of their effects on CCG rate and CCI time of welded joints. Under the condition of low geometry constraint, the effect of material constraint on CCG rate and CCI time becomes more obvious. Higher material constraint can promote CCG due to the formation of higher stress triaxiality around crack tip. Higher geometry constraint can increase CCG rate and reduce CCI time of welded joints. Both geometry and material constraints should be considered in creep life assessment and design for high-temperature welded components.

  7. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation

    PubMed Central

    Torkaman, Ali; Bagherifard, Abolfazl; Mokhatri, Tahmineh; Haghighi, Mohammad Hossein Shabanpour; Monshizadeh, Siamak; Taraz, Hamid; Hasanvand, Amin

    2016-01-01

    Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH), constant and visual analogue scale (VAS) scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71%) were male and four (14.28%) were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements. There were not any significant differences between right and left coracoclavicular, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments. PMID:26894217

  8. First demonstration and field trial on multi-user UDWDM-PON full duplex PSK-PSK with single monolithic integrated dual-output-DFB-SOA based ONUs.

    PubMed

    Chu, GuangYong; Maho, Anaëlle; Cano, Iván; Polo, Victor; Brenot, Romain; Debrégeas, Hélène; Prat, Josep

    2016-10-15

    We demonstrate a monolithically integrated dual-output DFB-SOA, and conduct the field trial on a multi-user bidirectional coherent ultradense wavelength division multiplexing-passive optical network (UDWDM-PON). To the best of our knowledge, this is the first achievement of simplified single integrated laser-based neighboring coherent optical network units (ONUs) with a 12.5 GHz channel spaced ultra-dense access network, including both downstream and upstream, taking the benefits of low footprint and low-temperature dependence.

  9. Subleading soft theorem for multiple soft gravitons

    NASA Astrophysics Data System (ADS)

    Chakrabarti, Subhroneel; Kashyap, Sitender Pratap; Sahoo, Biswajit; Sen, Ashoke; Verma, Mritunjay

    2017-12-01

    We derive the subleading soft graviton theorem in a generic quantum theory of gravity for arbitrary number of soft external gravitons and arbitrary number of finite energy external states carrying arbitrary mass and spin. Our results are valid to all orders in perturbation theory when the number of non-compact space-time dimensions is six or more, but only for tree amplitudes for five or less non-compact space-time dimensions due to enhanced contribution to loop amplitudes from the infrared region.

  10. Multigait soft robot

    PubMed Central

    Shepherd, Robert F.; Ilievski, Filip; Choi, Wonjae; Morin, Stephen A.; Stokes, Adam A.; Mazzeo, Aaron D.; Chen, Xin; Wang, Michael; Whitesides, George M.

    2011-01-01

    This manuscript describes a unique class of locomotive robot: A soft robot, composed exclusively of soft materials (elastomeric polymers), which is inspired by animals (e.g., squid, starfish, worms) that do not have hard internal skeletons. Soft lithography was used to fabricate a pneumatically actuated robot capable of sophisticated locomotion (e.g., fluid movement of limbs and multiple gaits). This robot is quadrupedal; it uses no sensors, only five actuators, and a simple pneumatic valving system that operates at low pressures (< 10 psi). A combination of crawling and undulation gaits allowed this robot to navigate a difficult obstacle. This demonstration illustrates an advantage of soft robotics: They are systems in which simple types of actuation produce complex motion. PMID:22123978

  11. Changes in ankle joint motion after Supramalleolar osteotomy: a cadaveric model.

    PubMed

    Kim, Hak Jun; Yeo, Eui Dong; Rhyu, Im Joo; Lee, Soon-Hyuck; Lee, Yeon Soo; Lee, Young Koo

    2017-09-09

    Malalignment of the ankle joint has been found after trauma, by neurological disorders, genetic predisposition and other unidentified factors, and results in asymmetrical joint loading. For a medial open wedge supramalleolar osteotomy(SMO), there are some debates as to whether concurrent fibular osteotomy should be performed. We assessed the changes in motion of ankle joint and plantar pressure after supramalleolar osteotomy without fibular osteotomy. Ten lower leg specimens below the knee were prepared from fresh-frozen human cadavers. They were harvested from five males (10 ankles)whose average age was 70 years. We assessed the motion of ankle joint as well as plantar pressure for SS(supra-syndesmotic) SMO and IS(intra-syndesmotic) SMO. After the osteotomy, each specimen was subjected to axial compression from 20 N preload to 350 N representing half-body weight. For the measurement of the motion of ankle joint, the changes in gap and point, angles in ankle joint were measured. The plantar pressure were also recorded using TekScan sensors. The changes in the various gap, point, and angles movements on SS-SMO and IS-SMO showed no statistically significant differences between the two groups. Regarding the shift of plantar center of force (COF) were noted in the anterolateral direction, but not statistically significant. SS-SMO and IS-SMO with intact fibula showed similar biomechanical effect on the ankle joint. We propose that IS-SMO should be considered carefully for the treatment of osteoarthrosis when fibular osteotomy is not performed because lateral cortex fracture was less likely using the intrasyndesmosis plane because of soft tissue support.

  12. Management of Osseous and Soft-Tissue Ankle Equinus During Total Ankle Replacement.

    PubMed

    Roukis, Thomas S; Simonson, Devin C

    2015-10-01

    Obtaining functional alignment of a total ankle replacement, including physiologic sagittal plane range of motion, is paramount for a successful outcome. This article reviews the literature on techniques available for correction of osseous and soft-tissue equinus at the time of index total ankle replacement. These techniques include anterior tibiotalar joint cheilectomy, posterior superficial muscle compartment lengthening, posterior ankle capsule release, and release of the posterior portions of the medial and lateral collateral ligament complexes. The rationale for these procedures and the operative sequence of events for these procedures are presented. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Fundamentals of soft robot locomotion

    PubMed Central

    2017-01-01

    Soft robotics and its related technologies enable robot abilities in several robotics domains including, but not exclusively related to, manipulation, manufacturing, human–robot interaction and locomotion. Although field applications have emerged for soft manipulation and human–robot interaction, mobile soft robots appear to remain in the research stage, involving the somehow conflictual goals of having a deformable body and exerting forces on the environment to achieve locomotion. This paper aims to provide a reference guide for researchers approaching mobile soft robotics, to describe the underlying principles of soft robot locomotion with its pros and cons, and to envisage applications and further developments for mobile soft robotics. PMID:28539483

  14. Fundamentals of soft robot locomotion.

    PubMed

    Calisti, M; Picardi, G; Laschi, C

    2017-05-01

    Soft robotics and its related technologies enable robot abilities in several robotics domains including, but not exclusively related to, manipulation, manufacturing, human-robot interaction and locomotion. Although field applications have emerged for soft manipulation and human-robot interaction, mobile soft robots appear to remain in the research stage, involving the somehow conflictual goals of having a deformable body and exerting forces on the environment to achieve locomotion. This paper aims to provide a reference guide for researchers approaching mobile soft robotics, to describe the underlying principles of soft robot locomotion with its pros and cons, and to envisage applications and further developments for mobile soft robotics. © 2017 The Author(s).

  15. An Evaluation of Global and Local Tensile Properties of Friction-Stir Welded DP980 Dual-Phase Steel Joints Using a Digital Image Correlation Method

    PubMed Central

    Lee, Hyoungwook; Kim, Cheolhee; Song, Jung Han

    2015-01-01

    The effect of the microstructure heterogeneity on the tensile plastic deformation characteristic of friction-stir-welded (FSW) dual-phase (DP) steel was investigated for the potential applications on the lightweight design of vehicles. Friction-stir-welded specimens with a butt joint configuration were prepared, and quasi-static tensile tests were conducted, to evaluate the tensile properties of DP980 dual-phase steels. The friction-stir welding led to the formation of martensite and a significant hardness rise in the stir zone (SZ), but the presence of a soft zone in the heat-affected zone (HAZ) was caused by tempering of the pre-existing martensite. Owing to the appearance of severe soft zone, DP980 FSW joint showed almost 93% joint efficiency with the view-point of ultimate tensile strength and relatively low ductility than the base metal (BM). The local tensile deformation characteristic of the FSW joints was also examined using the digital image correlation (DIC) methodology by mapping the global and local strain distribution, and was subsequently analyzed by mechanics calculation. It is found that the tensile deformation of the FSW joints is highly heterogeneous, leading to a significant decrease in global ductility. The HAZ of the joints is the weakest region where the strain localizes early, and this localization extends until fracture with a strain near 30%, while the strain in the SZ and BM is only 1% and 4%, respectively. Local constitutive properties in different heterogeneous regions through the friction-stir-welded joint was also briefly evaluated by assuming iso-stress conditions. The local stress-strain curves of individual weld zones provide a clear indication of the heterogeneity of the local mechanical properties. PMID:28793720

  16. An Evaluation of Global and Local Tensile Properties of Friction-Stir Welded DP980 Dual-Phase Steel Joints Using a Digital Image Correlation Method.

    PubMed

    Lee, Hyoungwook; Kim, Cheolhee; Song, Jung Han

    2015-12-04

    The effect of the microstructure heterogeneity on the tensile plastic deformation characteristic of friction-stir-welded (FSW) dual-phase (DP) steel was investigated for the potential applications on the lightweight design of vehicles. Friction-stir-welded specimens with a butt joint configuration were prepared, and quasi-static tensile tests were conducted, to evaluate the tensile properties of DP980 dual-phase steels. The friction-stir welding led to the formation of martensite and a significant hardness rise in the stir zone (SZ), but the presence of a soft zone in the heat-affected zone (HAZ) was caused by tempering of the pre-existing martensite. Owing to the appearance of severe soft zone, DP980 FSW joint showed almost 93% joint efficiency with the view-point of ultimate tensile strength and relatively low ductility than the base metal (BM). The local tensile deformation characteristic of the FSW joints was also examined using the digital image correlation (DIC) methodology by mapping the global and local strain distribution, and was subsequently analyzed by mechanics calculation. It is found that the tensile deformation of the FSW joints is highly heterogeneous, leading to a significant decrease in global ductility. The HAZ of the joints is the weakest region where the strain localizes early, and this localization extends until fracture with a strain near 30%, while the strain in the SZ and BM is only 1% and 4%, respectively. Local constitutive properties in different heterogeneous regions through the friction-stir-welded joint was also briefly evaluated by assuming iso-stress conditions. The local stress-strain curves of individual weld zones provide a clear indication of the heterogeneity of the local mechanical properties.

  17. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    PubMed

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Teaching Soft Skills Employers Need

    ERIC Educational Resources Information Center

    Ellis, Maureen; Kisling, Eric; Hackworth, Robbie G.

    2014-01-01

    This study identifies the soft skills community colleges teach in an office technology course and determines whether the skills taught are congruent with the soft skills employers require in today's entry-level office work. A qualitative content analysis of a community college office technology soft skills course was performed using 23 soft skills…

  19. GoQBot: a caterpillar-inspired soft-bodied rolling robot.

    PubMed

    Lin, Huai-Ti; Leisk, Gary G; Trimmer, Barry

    2011-06-01

    Rolling locomotion using an external force such as gravity has evolved many times. However, some caterpillars can curl into a wheel and generate their own rolling momentum as part of an escape repertoire. This change in body conformation occurs well within 100 ms and generates a linear velocity over 0.2 m s(-1), making it one of the fastest self-propelled wheeling behaviors in nature. Inspired by this behavior, we construct a soft-bodied robot to explore the dynamics and control issues of ballistic rolling. This robot, called GoQBot, closely mimics caterpillar rolling. Analyzing the whole body kinematics and 2D ground reaction forces at the robot ground anchor reveals about 1G of acceleration and more than 200 rpm of angular velocity. As a novel rolling robot, GoQBot demonstrates how morphing can produce new modes of locomotion. Furthermore, mechanical coupling of the actuators improves body coordination without sensory feedback. Such coupling is intrinsic to soft-bodied animals because there are no joints to isolate muscle-generated movements. Finally, GoQBot provides an estimate of the mechanical power for caterpillar rolling that is comparable to that of a locust jump. How caterpillar musculature produces such power in such a short time is yet to be discovered.

  20. Joint Transmit Power Allocation and Splitting for SWIPT Aided OFDM-IDMA in Wireless Sensor Networks

    PubMed Central

    Li, Shanshan; Zhou, Xiaotian; Wang, Cheng-Xiang; Yuan, Dongfeng; Zhang, Wensheng

    2017-01-01

    In this paper, we propose to combine Orthogonal Frequency Division Multiplexing-Interleave Division Multiple Access (OFDM-IDMA) with Simultaneous Wireless Information and Power Transfer (SWIPT), resulting in SWIPT aided OFDM-IDMA scheme for power-limited sensor networks. In the proposed system, the Receive Node (RN) applies Power Splitting (PS) to coordinate the Energy Harvesting (EH) and Information Decoding (ID) process, where the harvested energy is utilized to guarantee the iterative Multi-User Detection (MUD) of IDMA to work under sufficient number of iterations. Our objective is to minimize the total transmit power of Source Node (SN), while satisfying the requirements of both minimum harvested energy and Bit Error Rate (BER) performance from individual receive nodes. We formulate such a problem as a joint power allocation and splitting one, where the iteration number of MUD is also taken into consideration as the key parameter to affect both EH and ID constraints. To solve it, a sub-optimal algorithm is proposed to determine the power profile, PS ratio and iteration number of MUD in an iterative manner. Simulation results verify that the proposed algorithm can provide significant performance improvement. PMID:28677636

  1. Joint Transmit Power Allocation and Splitting for SWIPT Aided OFDM-IDMA in Wireless Sensor Networks.

    PubMed

    Li, Shanshan; Zhou, Xiaotian; Wang, Cheng-Xiang; Yuan, Dongfeng; Zhang, Wensheng

    2017-07-04

    In this paper, we propose to combine Orthogonal Frequency Division Multiplexing-Interleave Division Multiple Access (OFDM-IDMA) with Simultaneous Wireless Information and Power Transfer (SWIPT), resulting in SWIPT aided OFDM-IDMA scheme for power-limited sensor networks. In the proposed system, the Receive Node (RN) applies Power Splitting (PS) to coordinate the Energy Harvesting (EH) and Information Decoding (ID) process, where the harvested energy is utilized to guarantee the iterative Multi-User Detection (MUD) of IDMA to work under sufficient number of iterations. Our objective is to minimize the total transmit power of Source Node (SN), while satisfying the requirements of both minimum harvested energy and Bit Error Rate (BER) performance from individual receive nodes. We formulate such a problem as a joint power allocation and splitting one, where the iteration number of MUD is also taken into consideration as the key parameter to affect both EH and ID constraints. To solve it, a sub-optimal algorithm is proposed to determine the power profile, PS ratio and iteration number of MUD in an iterative manner. Simulation results verify that the proposed algorithm can provide significant performance improvement.

  2. Correlative analysis of hard and soft x ray observations of solar flares

    NASA Technical Reports Server (NTRS)

    Zarro, Dominic M.

    1994-01-01

    We have developed a promising new technique for jointly analyzing BATSE hard X-ray observations of solar flares with simultaneous soft X-ray observations. The technique is based upon a model in which electric currents and associated electric fields are responsible for the respective heating and particle acceleration that occur in solar flares. A useful by-product of this technique is the strength and evolution of the coronal electric field. The latter permits one to derive important flare parameters such as the current density, the number of current filaments composing the loop, and ultimately the hard X-ray spectrum produced by the runaway electrons. We are continuing to explore the technique by applying it to additional flares for which we have joint BATSE/Yohkoh observations. A central assumption of our analysis is the constant of proportionality alpha relating the hard X-ray flux above 50 keV and the rate of electron acceleration. For a thick-target model of hard X-ray production, it can be shown that cv is in fact related to the spectral index and low-energy cutoff of precipitating electrons. The next step in our analysis is to place observational constraints on the latter parameters using the joint BATSE/Yohkoh data.

  3. Autofeedback from ultrasound images provides rapid improvement in palpation skills for identifying joint swelling in rheumatoid arthritis.

    PubMed

    Ogasawara, Michihiro; Murayama, Go; Yamada, Yusuke; Nemoto, Takuya; Kageyama, Michiaki; Toyama, Shoko; Kusaoi, Makio; Onuma, Shin; Kon, Takayuki; Sekiya, Fumio; Sugimoto, Kaoru; Matsudaira, Ran; Matsushita, Masakazu; Tada, Kurisu; Kempe, Kazuo; Yamaji, Ken; Tamura, Naoto; Takasaki, Yoshinari

    2012-06-01

    Joint swelling, an important factor in the classification criteria and disease activity assessment in rheumatoid arthritis (RA), renders joint palpation a necessary skill for physicians. Ultrasound (US) examination that visualizes soft tissue abnormalities is now used to assess musculoskeletal disease. We assessed the usefulness of US assessments in enhancing physical joint examination skills. We examined 1944 joints (bilateral shoulder, elbow, wrist, metacarpophalangeal joints 1-5, and knee joints) in 108 patients with RA during April-July 2011. We first physically examined and confirmed joint swelling; subsequently, the same rheumatologist conducted US examinations and multiple assessors graded the joint swelling. When the 2 results differed, we received autofeedback from the US results to improve the physical examination skills. The sensitivities and specificities of physical examination for US-detected swollen joint, the correlation coefficient (CC) of the swollen joint counts, and the concordance rate in each patient for joint swelling sites and power Doppler (PD)-positive sites with the κ coefficients between the physical and US examinations were compared over time. We found that the sensitivity of physical examination increased by 42 percentage points (pp), while the specificity decreased by 18 pp. The average CC in June-July was greater than that in April-May. The percentage of κ coefficients > 0.8 increased from 8.8% to 17% for joint swelling and from 8.3% to 14% for PD-positive sites. Our results suggest that autofeedback from US assessment provides quick improvement in palpation skills for identifying joint swelling in patients with RA.

  4. Repair of large full-thickness articular cartilage defects in the rabbit: the effects of joint distraction and autologous bone-marrow-derived mesenchymal cell transplantation.

    PubMed

    Yanai, T; Ishii, T; Chang, F; Ochiai, N

    2005-05-01

    We produced large full-thickness articular cartilage defects in 33 rabbits in order to evaluate the effect of joint distraction and autologous culture-expanded bone-marrow-derived mesenchymal cell transplantation (ACBMT) at 12 weeks. After fixing the knee on a hinged external fixator, we resected the entire surface of the tibial plateau. We studied three groups: 1) with and without joint distraction; 2) with joint distraction and collagen gel, and 3) with joint distraction and ACBMT and collagen gel. The histological scores were significantly higher in the groups with ACBMT collagen gel (p < 0.05). The area of regenerated soft tissue was smaller in the group allowed to bear weight (p < 0.05). These findings suggest that the repair of large defects of cartilage can be enhanced by joint distraction, collagen gel and ACBMT.

  5. Efficiently Multi-User Searchable Encryption Scheme with Attribute Revocation and Grant for Cloud Storage

    PubMed Central

    Wang, Shangping; Zhang, Xiaoxue; Zhang, Yaling

    2016-01-01

    Cipher-policy attribute-based encryption (CP-ABE) focus on the problem of access control, and keyword-based searchable encryption scheme focus on the problem of finding the files that the user interested in the cloud storage quickly. To design a searchable and attribute-based encryption scheme is a new challenge. In this paper, we propose an efficiently multi-user searchable attribute-based encryption scheme with attribute revocation and grant for cloud storage. In the new scheme the attribute revocation and grant processes of users are delegated to proxy server. Our scheme supports multi attribute are revoked and granted simultaneously. Moreover, the keyword searchable function is achieved in our proposed scheme. The security of our proposed scheme is reduced to the bilinear Diffie-Hellman (BDH) assumption. Furthermore, the scheme is proven to be secure under the security model of indistinguishability against selective ciphertext-policy and chosen plaintext attack (IND-sCP-CPA). And our scheme is also of semantic security under indistinguishability against chosen keyword attack (IND-CKA) in the random oracle model. PMID:27898703

  6. Efficiently Multi-User Searchable Encryption Scheme with Attribute Revocation and Grant for Cloud Storage.

    PubMed

    Wang, Shangping; Zhang, Xiaoxue; Zhang, Yaling

    2016-01-01

    Cipher-policy attribute-based encryption (CP-ABE) focus on the problem of access control, and keyword-based searchable encryption scheme focus on the problem of finding the files that the user interested in the cloud storage quickly. To design a searchable and attribute-based encryption scheme is a new challenge. In this paper, we propose an efficiently multi-user searchable attribute-based encryption scheme with attribute revocation and grant for cloud storage. In the new scheme the attribute revocation and grant processes of users are delegated to proxy server. Our scheme supports multi attribute are revoked and granted simultaneously. Moreover, the keyword searchable function is achieved in our proposed scheme. The security of our proposed scheme is reduced to the bilinear Diffie-Hellman (BDH) assumption. Furthermore, the scheme is proven to be secure under the security model of indistinguishability against selective ciphertext-policy and chosen plaintext attack (IND-sCP-CPA). And our scheme is also of semantic security under indistinguishability against chosen keyword attack (IND-CKA) in the random oracle model.

  7. Experimental soft-matter science

    NASA Astrophysics Data System (ADS)

    Nagel, Sidney R.

    2017-04-01

    Soft materials consist of basic units that are significantly larger than an atom but much smaller than the overall dimensions of the sample. The label "soft condensed matter" emphasizes that the large basic building blocks of these materials produce low elastic moduli that govern a material's ability to withstand deformations. Aside from softness, there are many other properties that are also caused by the large size of the constituent building blocks. Soft matter is dissipative, disordered, far from equilibrium, nonlinear, thermal and entropic, slow, observable, gravity affected, patterned, nonlocal, interfacially elastic, memory forming, and active. This is only a partial list of how matter created from large component particles is distinct from "hard matter" composed of constituents at an atomic scale. Issues inherent in soft matter raise problems that are broadly important in diverse areas of science and require multiple modes of attack. For example, far-from-equilibrium behavior is confronted in biology, chemistry, geophysics, astrophysics, and nuclear physics. Similarly, issues dealing with disorder appear broadly throughout many branches of inquiry wherever rugged landscapes are invoked. This article reviews the discussions that occurred during a workshop held on 30-31 January 2016 in which opportunities in soft-matter experiment were surveyed. Soft matter has had an exciting history of discovery and continues to be a fertile ground for future research.

  8. Fatal hemorrhage following sacroiliac joint fusion surgery: A case report.

    PubMed

    Palmiere, Cristian; Augsburger, Marc; Del Mar Lesta, Maria; Grabherr, Silke; Borens, Olivier

    2017-05-01

    Threaded pins and wires are commonly used in orthopedic practice and their migration intra- or post-operatively may be responsible for potentially serious complications. Vascular and visceral injury from intra-pelvic pin or guide-wire migration during or following hip surgery has been reported frequently in the literature and may result in progression through soft tissues with subsequent perforation of organs and vessels. In this report, we describe an autopsy case involving a 40-year old man suffering from chronic low back pain due to sacroiliac joint disruption. The patient underwent minimally invasive sacroiliac joint arthrodesis. Some intra-operative bleeding was noticed when a drill was retrieved, though the patient died postoperatively. Postmortem investigations allowed the source of bleeding to be identified (a perforation of a branch of the right internal iliac artery) and a potentially toxic tramadol concentration in peripheral blood to be measured. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Application of three-dimensional rendering in joint-related ganglion cysts.

    PubMed

    Spinner, Robert J; Edwards, Phillip K; Amrami, Kimberly K

    2006-05-01

    with standard MR imaging. We believe that these joint-related cysts have a common pathogenesis; they dissect through a capsular rent and follow the path of least resistance; they may form simple cysts by dissecting out into the soft tissue, or more complex cysts by dissecting within the epineurium of nerves or adventitia of vessels (along an articular branch), or various combinations of all of these types of cysts. Understanding the pathogenesis for cyst formation will improve surgical management and outcomes. We have adapted this 3D technique to enhance the visualization of cysts occurring at other joints.

  10. [Treatment of bacterial infection in the interphalangeal joints of the hand].

    PubMed

    Vorderwinkler, K-P; Mühldorfer, M; Pillukat, T; van Schoonhoven, J

    2011-07-01

    Radical debridement of joint infection, prevention of further infection-related tissue destruction. Septic arthritis of interphalangeal joints in the thumb and fingers. Extensive soft tissue defects. Severe impairment of blood circulation, finger gangrene. Noncompliance for immobilization or for treatment with external fixator. Arthrotomy and irrigation with isotonic solution. Radical tissue debridement. Joint preservation possible only in the absence of infection-related macroscopic cartilage damage. Otherwise, resection of the articular surfaces and secondary arthrodesis. Insertion of antibiotic-coated devices. Temporary immobilization with external fixator. Inpatient postoperative treatment with 5-day intravenous administration of a second-generation cephalosporine (e.g., Cefuroxim®) followed by 7-10 days oral application. Adaptation of antibiotics according to antibiogram results. In joint-preserving procedures, radiographs and fixator removal after 4 weeks, active joint mobilization. If joint surfaces were resected, removal of fixator after 6 weeks; arthrodesis under 3-day intravenous broad-band antibiotic prophylaxis. Splint immobilization until consolidation (6-8 weeks). In 10 of 40 patients, the infected joint could be preserved. All infections healed. After an average duration of therapy of 6 (3-11) weeks, 4 individuals were free of complaints, and 6 patients had minor symptoms. Overall range of motion in the affected finger was reduced by 25-50° in 5 patients. All patients could return to work after 6.6 (4-11) weeks. A total of 30 patients were treated with joint resection and external fixator. After 5.6 (4-8) weeks, arthrodesis was performed, leading to consolidation in 29 patients. One patient underwent amputation after 4 months due to delayed gangrene. Treatment duration was 15.7 (7-25) weeks. Eight patients reported no complaints, 14 suffered mild symptoms, 5 had moderate, and 3 had severe symptoms in daily life. In 15 cases, range

  11. Computational dynamics of soft machines

    NASA Astrophysics Data System (ADS)

    Hu, Haiyan; Tian, Qiang; Liu, Cheng

    2017-06-01

    Soft machine refers to a kind of mechanical system made of soft materials to complete sophisticated missions, such as handling a fragile object and crawling along a narrow tunnel corner, under low cost control and actuation. Hence, soft machines have raised great challenges to computational dynamics. In this review article, recent studies of the authors on the dynamic modeling, numerical simulation, and experimental validation of soft machines are summarized in the framework of multibody system dynamics. The dynamic modeling approaches are presented first for the geometric nonlinearities of coupled overall motions and large deformations of a soft component, the physical nonlinearities of a soft component made of hyperelastic or elastoplastic materials, and the frictional contacts/impacts of soft components, respectively. Then the computation approach is outlined for the dynamic simulation of soft machines governed by a set of differential-algebraic equations of very high dimensions, with an emphasis on the efficient computations of the nonlinear elastic force vector of finite elements. The validations of the proposed approaches are given via three case studies, including the locomotion of a soft quadrupedal robot, the spinning deployment of a solar sail of a spacecraft, and the deployment of a mesh reflector of a satellite antenna, as well as the corresponding experimental studies. Finally, some remarks are made for future studies.

  12. Joint hypermobility syndrome in childhood. A not so benign multisystem disorder?

    PubMed

    Adib, N; Davies, K; Grahame, R; Woo, P; Murray, K J

    2005-06-01

    Joint hypermobility (JH) or "ligamentous laxity" is felt to be an underlying risk factor for many types of musculoskeletal presentation in paediatrics, and joint hypermobility syndrome (JHS) describes such disorders where symptoms become chronic, often more generalized and associated with functional impairment. Clinical features are felt to have much in common with more severe disorders, including Ehlers-Danlos syndrome (EDS), osteogenesis imperfecta and Marfan syndrome, although this has not been formally studied in children. We defined the clinical characteristics of all patients with joint hypermobility-related presentations seen from 1999 to 2002 in a tertiary referral paediatric rheumatology unit. Patients were identified and recruited from paediatric rheumatology clinic and ward, and a dedicated paediatric rheumatology hypermobility clinic at Great Ormond Street Hospital. Data were collected retrospectively on the patients from the paediatric rheumatology clinics (1999-2002) and prospectively on patients seen in the hypermobility clinic (2000-2002). Specifically, historical details of developmental milestones, musculoskeletal or soft tissue diagnoses and symptoms, and significant past medical history were recorded. Examination features sought included measurements of joint and soft tissue laxity, and associated conditions such as scoliosis, dysmorphic features, cardiac murmurs and eye problems. One hundred and twenty-five children (64 females) were included on whom sufficient clinical data could be identified and who had clinical problems ascribed to JH present for longer than 3 months. Sixty-four were from the paediatric rheumatology clinic and 61 from the hypermobility clinic. No differences were found in any of the measures between the two populations and results are presented in a combined fashion. Three-quarters of referrals came from paediatricians and general practitioners but in only 10% was hypermobility recognized as a possible cause of joint

  13. A multi-user real time inventorying system for radioactive materials: a networking approach.

    PubMed

    Mehta, S; Bandyopadhyay, D; Hoory, S

    1998-01-01

    A computerized system for radioisotope management and real time inventory coordinated across a large organization is reported. It handles hundreds of individual users and their separate inventory records. Use of highly efficient computer network and database technologies makes it possible to accept, maintain, and furnish all records related to receipt, usage, and disposal of the radioactive materials for the users separately and collectively. The system's central processor is an HP-9000/800 G60 RISC server and users from across the organization use their personal computers to login to this server using the TCP/IP networking protocol, which makes distributed use of the system possible. Radioisotope decay is automatically calculated by the program, so that it can make the up-to-date radioisotope inventory data of an entire institution available immediately. The system is specifically designed to allow use by large numbers of users (about 300) and accommodates high volumes of data input and retrieval without compromising simplicity and accuracy. Overall, it is an example of a true multi-user, on-line, relational database information system that makes the functioning of a radiation safety department efficient.

  14. Neuropathic Arthropathy of the Glenohumeral Joint A Review of the Literature.

    PubMed

    Santiesteban, Lauren; Mollon, Brent; Zuckerman, Joseph D

    2018-06-01

    Neuropathic arthropathy, also known as Charcot arthropathy, is a degenerative disorder most commonly characterized by rapid destruction of the joint with extensive involvement of the bone and soft tissue. The underlying pathophysiology is thought to be due to loss of nociception (pain sensation), most frequently caused by diabetes mellitus, syphilitic myelopathy, or syringomyelia. A neuropathic shoulder is rare, with historic case series forming the bulk of the literature. The purpose of this review is to better understand the pathogenesis, clinical presentation, and management of neuropathic arthropathy of the glenohumeral joint. It should be stressed that the identification and management of the underlying etiology is paramount if the disease process is to be positively impacted. Although the mainstay of orthopedic management is non-surgical, little evidence exists to support the use of any specific therapeutic intervention. Recent literature suggests surgical reconstruction may be considered in very select patients.

  15. Live theater on a virtual stage: incorporating soft skills and teamwork in computer graphics education.

    PubMed

    Schweppe, M; Geigel, J

    2011-01-01

    Industry has increasingly emphasized the need for "soft" or interpersonal skills development and team-building experience in the college curriculum. Here, we discuss our experiences with providing such opportunities via a collaborative project called the Virtual Theater. In this joint project between the Rochester Institute of Technology's School of Design and Department of Computer Science, the goal is to enable live performance in a virtual space with participants in different physical locales. Students work in teams, collaborating with other students in and out of their disciplines.

  16. Soft optics in intelligent optical networks

    NASA Astrophysics Data System (ADS)

    Shue, Chikong; Cao, Yang

    2001-10-01

    In addition to the recent advances in Hard-optics that pushes the optical transmission speed, distance, wave density and optical switching capacity, Soft-optics provides the necessary intelligence and control software that reduces operational costs, increase efficiency, and enhances revenue generating services by automating optimal optical circuit placement and restoration, and enabling value-added new services like Optical VPN. This paper describes the advances in 1) Overall Hard-optics and Soft-optics 2) Layered hierarchy of Soft-optics 3) Component of Soft-optics, including hard-optics drivers, Management Soft-optics, Routing Soft-optics and System Soft-optics 4) Key component of Routing and System Soft-optics, namely optical routing and signaling (including UNI/NNI and GMPLS signaling). In summary, the soft-optics on a new generation of OXC's enables Intelligent Optical Networks to provide just-in-time service delivery and fast restoration, and real-time capacity management that eliminates stranded bandwidth. It reduces operational costs and provides new revenue opportunities.

  17. [Soft-drinks and health].

    PubMed

    Amato, D; Maravilla, A; García-Contreras, F; Paniagua, R

    1997-01-01

    To analyze published papers about soft drinks use, and to describe possible health benefits, risks, and damages related to soft drink consumption. INFORMATION SOURCE: A search was done in the MEDLINE compact disks, from January 1970 to January 1997, with the keywords soft drink, beverages, carbonated beverages, cola, Coca-Cola and sweetening-agents. Ninety nine papers reporting health-related damages or benefits in clinical or experimental studies were reviewed. All articles with a clear description of at least one beneficial or harmful effect related to soft drink consumption were considered. There were reports on 25 harmful effects and of 7 possibly beneficial effects. Data are classified in prophylactic and therapeutic uses, dental caries and other dental disorders, mineral metabolism disorders, acid-peptic disease, neoplasm, risk factors for cardiovascular disease, effects on central nervous system, reproduction, allergy, and miscellaneous. High prevalence of exposure and excessive consumption of soft drinks may represent a public health problem in Mexico. Data analysis shows that soft drink consumption may not be as harmless as generally believed. Many of the reports are anecdotal, without a suitable methodological design. A wide field for research is present in this area.

  18. Infrared target recognition based on improved joint local ternary pattern

    NASA Astrophysics Data System (ADS)

    Sun, Junding; Wu, Xiaosheng

    2016-05-01

    This paper presents a simple, efficient, yet robust approach, named joint orthogonal combination of local ternary pattern, for automatic forward-looking infrared target recognition. It gives more advantages to describe the macroscopic textures and microscopic textures by fusing variety of scales than the traditional LBP-based methods. In addition, it can effectively reduce the feature dimensionality. Further, the rotation invariant and uniform scheme, the robust LTP, and soft concave-convex partition are introduced to enhance its discriminative power. Experimental results demonstrate that the proposed method can achieve competitive results compared with the state-of-the-art methods.

  19. Intra-articular soft-tissue masses of the ankle. Meniscoid lesions and transarticular fibrous bands.

    PubMed

    Stienstra, J J

    1994-07-01

    Meniscoid lesions and fibrous bands are unique lesions, most likely of differing origin. Although they are similar in clinical presentation, their appearance at arthroscopy is clearly different. The meniscoid lesion is attached only at its origin at the inferolateral gutter on the anterior talofibular ligament. Fibrous bands are attached at two ends and may be found anywhere in the joint but are most common extending dramatically over the anterior joint line. Unexpected encountering of a fibrous band should alert the surgeon to carefully inspect the joint for other associated (occult) pathology. Because of the frequent association of bands with antecedent fracture, the observation of this lesion should lead the clinician to consider antecedent intra-articular fracture (transchondral fracture, malleolar fracture, and tibial pilon fracture) as a likely co-pathology. Careful examination of the ankle and review of the radiographs and other available images may be helpful in assessing the joint for these injuries when fibrous bands are encountered. The association of meniscoid lesion with prior soft tissue injury (sprain) is also important to understanding this lesion. Excision of both these abnormal lesions in concert with repair of coexistent pathology is associated with improvement of symptoms. Finally, both fibrous bands and meniscoid lesions are associated with symptoms that warrant closer inspection and observation. Whether the operative intervention is open or closed, the reader can benefit from the information presented.

  20. Fetlock joint kinematics differ with age in Thoroughbred [was thoroughbred] racehorses.

    PubMed

    Butcher, Michael T; Ashley-Ross, M A

    2002-05-01

    Fetlock joint kinematics during galloping in 2-, 3-, 4-, and 5-year-old Thoroughbreds in race training were quantified to determine if differences due to age could account for the observation that 2-year old Thoroughbred racehorses incur a high number of injuries to the bones and soft tissues in the distal forelimbs during training and at the outset of racing. Twelve Thoroughbred racehorses were videotaped in the sagittal plane at 250 frames/s during their daily galloping workout on a 7/8 mile sand-surface training track. Four galloping strides were recorded for each horse and subsequently digitized to determine fetlock joint angles of the leading forelimb during the limb support period of a stride. Four kinematic variables were measured from each stride's angular profile: angle of fetlock joint dorsi-flexion at mid-stance, negative angular velocity, positive angular velocity and time from hoof impact to mid-stance phase of limb support. The 2-year old Thoroughbreds had significantly quicker rates of dorsi-flexion of their fetlock joints than 3- (p=0.01), 4- (p=0.01), and 5-year old (p<0.01) Thoroughbreds following impact of the leading forelimb during moderate galloping (avg. 14 m/s). Higher rates of dorsi-flexion in young Thoroughbreds may reflect immaturity (lack of stiffness) of the suspensory apparatus tissues.

  1. The Geminga Pulsar: Soft X-Ray Variability and an EUVE Observation

    NASA Technical Reports Server (NTRS)

    Halpern, Jules P.; Martin, Christopher; Marshall, Herman L.; Oliversen, Ronald (Technical Monitor)

    2001-01-01

    We observed the Geminga pulsar with the EUVE satellite, detecting pulsed emission in the Deep Survey imager. Joint spectral fits of the EUVE flux with ROSAT PSPC data are consistent with thermal plus power-law models in which the thermal component makes the dominant contribution to the soft X-ray flux seen by EUVE and ROSAT. The data are consistent with blackbody emission of T = (4 - 6) x 10(exp 5) K over most of the surface of the star at the measured parallax distance of 160 pc. Although model atmospheres are more realistic, and can fit the data with effective temperatures a factor of 2 lower, current data would not discriminate between these and blackbody models. We also find evidence for variability of Geminga's soft X-ray pulse shape. Narrow dips in the light curve that were present in 1991 had largely disappeared in 1993/1994, causing the pulsed fraction to decline from 32% to 18%. If the dips are attributed to cyclotron resonance scattering by an e1 plasma on closed magnetic field lines, then the process that resupplies that plasma must be variable.

  2. The Geminga Pulsar: Soft X-Ray Variability and an EUVE Observation

    NASA Technical Reports Server (NTRS)

    Halpern, Jules P.; Martin, Christopher; Marshall, Herman L.

    1996-01-01

    We observed the Geminga pulsar with the EUVE satellite, detecting pulsed emission in the Deep Survey imager. Joint spectral fits of the EUVE flux with ROSAT PSPC data are consistent with thermal plus power-law models in which the thermal component makes the dominant contribution to the soft X-ray flux seen by EUVE and ROSAT. The data are consistent with blackbody emission of T = (4-6) x 10(exp 5) K over most of the surface of the star at the measured parallax distance of 160 pc. Although model atmospheres are more realistic, and can fit the data with effective temperatures a factor of 2 lower, current data would not discriminate between these and blackbody models. We also find evidence for variability of Geminga's soft X-ray pulse shape. Narrow dips in the light curve that were present in 1991 had largely disappeared in 1993/1994, causing the pulsed fraction to decline from 32% to 18%. If the dips are attributed to cyclotron resonance scattering by an e(+/-) plasma on closed magnetic field lines, then the process that resupplies that plasma must be variable.

  3. Surgical anatomy of the sternoclavicular joint: a qualitative and quantitative anatomical study.

    PubMed

    Lee, Jared T; Campbell, Kevin J; Michalski, Max P; Wilson, Katharine J; Spiegl, Ulrich J A; Wijdicks, Coen A; Millett, Peter J

    2014-10-01

    The quantitative anatomical relationships of the main ligamentous, tendinous, and osseous structures of the sternoclavicular joint have not been widely investigated. The purpose of this study was to provide a quantitative description of the sternoclavicular joint in relation to relevant surgical landmarks. We dissected eleven nonpaired, fresh-frozen cadaveric sternoclavicular joints from four men and seven women (mean age at death, fifty-three years; range, thirty-three to sixty-four years) and measured the ligaments, musculature, and osseous landmarks with use of a three-dimensional coordinate-measuring device. The clavicular pectoralis ridge, located at the 9:30 clock-face position on a right clavicle, served as a reliable osseous landmark for reference to the soft-tissue attachments around the sternoclavicular joint. The costoclavicular ligament was the largest ligament of the sternoclavicular joint, with 80% greater footprint area than that of the posterior sternoclavicular ligament. Articular cartilage covered 67% of the medial end of the clavicle and was located anteroinferiorly. The sternohyoid muscle inserted directly over the posterior sternoclavicular joint and the medial end of the clavicle, whereas the sternothyroid muscle inserted 9.5 mm inferior to the posterior-superior articular margin of the manubrium and coursed 19.8 mm laterally along the first rib. An avascular plane that can serve as a "safe zone" for posterior dissection was observed in each specimen, posterior to the sternoclavicular joint and anterior to the sternohyoid and sternothyroid muscles. The clavicular pectoralis ridge can be used as an intraoperative guide for clavicle orientation and tunnel placement in sternoclavicular ligament reconstruction. Sternoclavicular joint resection arthroplasty should avoid injuring the costoclavicular ligament, which is the largest sternoclavicular joint ligament. Resection of only the anteroinferior aspect of the medial end of the clavicle may

  4. Soft Hair on Black Holes

    NASA Astrophysics Data System (ADS)

    Hawking, Stephen W.; Perry, Malcolm J.; Strominger, Andrew

    2016-06-01

    It has recently been shown that Bondi-van der Burg-Metzner-Sachs supertranslation symmetries imply an infinite number of conservation laws for all gravitational theories in asymptotically Minkowskian spacetimes. These laws require black holes to carry a large amount of soft (i.e., zero-energy) supertranslation hair. The presence of a Maxwell field similarly implies soft electric hair. This Letter gives an explicit description of soft hair in terms of soft gravitons or photons on the black hole horizon, and shows that complete information about their quantum state is stored on a holographic plate at the future boundary of the horizon. Charge conservation is used to give an infinite number of exact relations between the evaporation products of black holes which have different soft hair but are otherwise identical. It is further argued that soft hair which is spatially localized to much less than a Planck length cannot be excited in a physically realizable process, giving an effective number of soft degrees of freedom proportional to the horizon area in Planck units.

  5. Fast-moving soft electronic fish.

    PubMed

    Li, Tiefeng; Li, Guorui; Liang, Yiming; Cheng, Tingyu; Dai, Jing; Yang, Xuxu; Liu, Bangyuan; Zeng, Zedong; Huang, Zhilong; Luo, Yingwu; Xie, Tao; Yang, Wei

    2017-04-01

    Soft robots driven by stimuli-responsive materials have unique advantages over conventional rigid robots, especially in their high adaptability for field exploration and seamless interaction with humans. The grand challenge lies in achieving self-powered soft robots with high mobility, environmental tolerance, and long endurance. We are able to advance a soft electronic fish with a fully integrated onboard system for power and remote control. Without any motor, the fish is driven solely by a soft electroactive structure made of dielectric elastomer and ionically conductive hydrogel. The electronic fish can swim at a speed of 6.4 cm/s (0.69 body length per second), which is much faster than previously reported untethered soft robotic fish driven by soft responsive materials. The fish shows consistent performance in a wide temperature range and permits stealth sailing due to its nearly transparent nature. Furthermore, the fish is robust, as it uses the surrounding water as the electric ground and can operate for 3 hours with one single charge. The design principle can be potentially extended to a variety of flexible devices and soft robots.

  6. Soft Hair on Black Holes.

    PubMed

    Hawking, Stephen W; Perry, Malcolm J; Strominger, Andrew

    2016-06-10

    It has recently been shown that Bondi-van der Burg-Metzner-Sachs supertranslation symmetries imply an infinite number of conservation laws for all gravitational theories in asymptotically Minkowskian spacetimes. These laws require black holes to carry a large amount of soft (i.e., zero-energy) supertranslation hair. The presence of a Maxwell field similarly implies soft electric hair. This Letter gives an explicit description of soft hair in terms of soft gravitons or photons on the black hole horizon, and shows that complete information about their quantum state is stored on a holographic plate at the future boundary of the horizon. Charge conservation is used to give an infinite number of exact relations between the evaporation products of black holes which have different soft hair but are otherwise identical. It is further argued that soft hair which is spatially localized to much less than a Planck length cannot be excited in a physically realizable process, giving an effective number of soft degrees of freedom proportional to the horizon area in Planck units.

  7. Soft skills and dental education.

    PubMed

    Gonzalez, M A G; Abu Kasim, N H; Naimie, Z

    2013-05-01

    Soft skills and hard skills are essential in the practice of dentistry. While hard skills deal with technical proficiency, soft skills relate to a personal values and interpersonal skills that determine a person's ability to fit in a particular situation. These skills contribute to the success of organisations that deal face-to-face with clients. Effective soft skills benefit the dental practice. However, the teaching of soft skills remains a challenge to dental schools. This paper discusses the different soft skills, how they are taught and assessed and the issues that need to be addressed in their teaching and assessment. The use of the module by the Faculty of Dentistry, University of Malaya for development of soft skills for institutions of higher learning introduced by the Ministry of Higher Education, Malaysia. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  8. Shoulder model validation and joint contact forces during wheelchair activities.

    PubMed

    Morrow, Melissa M B; Kaufman, Kenton R; An, Kai-Nan

    2010-09-17

    Chronic shoulder impingement is a common problem for manual wheelchair users. The loading associated with performing manual wheelchair activities of daily living is substantial and often at a high frequency. Musculoskeletal modeling and optimization techniques can be used to estimate the joint contact forces occurring at the shoulder to assess the soft tissue loading during an activity and to possibly identify activities and strategies that place manual wheelchair users at risk for shoulder injuries. The purpose of this study was to validate an upper extremity musculoskeletal model and apply the model to wheelchair activities for analysis of the estimated joint contact forces. Upper extremity kinematics and handrim wheelchair kinetics were measured over three conditions: level propulsion, ramp propulsion, and a weight relief lift. The experimental data were used as input to a subject-specific musculoskeletal model utilizing optimization to predict joint contact forces of the shoulder during all conditions. The model was validated using a mean absolute error calculation. Model results confirmed that ramp propulsion and weight relief lifts place the shoulder under significantly higher joint contact loading than level propulsion. In addition, they exhibit large superior contact forces that could contribute to impingement. This study highlights the potential impingement risk associated with both the ramp and weight relief lift activities. Level propulsion was shown to have a low relative risk of causing injury, but with consideration of the frequency with which propulsion is performed, this observation is not conclusive.

  9. Strategies of Parkour practitioners for executing soft precision landings.

    PubMed

    Maldonado, Galo; Soueres, Philippe; Watier, Bruno

    2018-04-25

    Parkour landing techniques differ from performances of other sports as they are practiced in urban spaces with uncontrolled surfaces and drop heights. Due to the relatively young age of the sport, few studies have tried to understand how practitioners - called traceurs - succeed at performing these dynamic performances. In this paper, we focus on the precision landing technique, which has a fundamental role in most of the Parkour motions. We analyzed the lower limbs motion of traceurs executing the precision landings from two different heights and compared their performance with untrained participants. We found that traceurs perform a soft landing extending its duration twice than untrained participants do [Formula: see text], increasing the range of motion [Formula: see text] and generating more mechanical energy [Formula: see text] to dissipate the impact. In the Parkour technique, the knee accounted for half of the energy dissipated. The peak joint torques [Formula: see text] and power [Formula: see text] were reduced in the Parkour technique. The increase of the landing height did not modify the proportion of individual joint mechanical energy contribution for dissipation. Our results could be used to enhance Parkour performance, and to understand new ways in which sport practitioners can land in order to prevent injuries.

  10. Does increased femoral antetorsion predispose to cartilage lesions of the patellofemoral joint?

    PubMed

    Oppermann, Johannes; Bredow, Jan; Wissusek, Boris; Spies, Christian Karl; Boese, Christoph Kolja; Chang, Shi-Min; Eysel, Peer; Dargel, Jens

    2017-09-01

    The purpose of this study was to investigate whether there was a relationship between femoral neck antetorsion and the presence and pattern of osteoarthritis of the patellofemoral joint. It was hypothesized that an increased femoral neck antetorsion (1) correlates with osteoarthritic changes of the lateral facet of the patellofemoral joint and (2) correlates with an increased lateral trochlear height and a decreased sulcus angle. Seventy-eight formalin-embedded cadaveric lower extremities from thirty-nine subjects with a median age of 74 years (range 60-88) were used. Surrounding soft tissues of the lower limb were removed. The femoral neck antetorsion was measured and referenced to the transepicondylar axis and the posterior condylar line. The height of the medial and lateral facet of the trochlea and the sulcus angle was measured. The location and the degree of patellofemoral cartilage degeneration were recorded. A Pearson's correlation analysis was performed to correlate the femoral neck antetorsion with the measured knee parameters. No significant correlation could be found between the femoral antetorsion and cartilage degeneration of the lateral patellofemoral joint (n.s.), the height of the lateral trochlea (n.s.) and the sulcus angle (n.s.). This study could not document that the femoral neck antetorsion and subsequent internal rotation of the distal femur correlated with the degree of degeneration of the lateral facet of the patellofemoral joint. Clinically, femoral internal rotation may play a minor role in the development of lateral patellofemoral joint degeneration.

  11. [Imaging of the elbow joint with focus MRI. Part 2: muscles, nerves and synovial membranes].

    PubMed

    Rehm, J; Zeifang, F; Weber, M-A

    2014-03-01

    This review article discusses the magnetic resonance imaging (MRI) features and pathological changes of muscles, nerves and the synovial lining of the elbow joint. Typical imaging findings are illustrated and discussed. In addition, the cross-sectional anatomy and anatomical variants, such as accessory muscles and plicae are discussed. Injuries of the muscles surrounding the elbow joint, as well as chronic irritation are particularly common in athletes. Morphological changes in MRI, for example tennis or golfer's elbow are typical and often groundbreaking. By adapting the examination sequences, imaging planes and slices, complete and incomplete tendon ruptures can be reliably diagnosed. Although the clinical and electrophysiological examinations form the basis for the diagnosis of peripheral neuropathies, MRI provides useful additional information about the precise localization due to its high resolution and good soft tissue contrast and helps to rule out differential diagnoses. Synovial diseases, such as inflammatory arthritis, proliferative diseases and also impinging plicae must be considered in the MRI diagnostics of the elbow joint.

  12. NENIMF: Northeast National Ion Microprobe Facility - A Multi-User Facility for SIMS Microanalysis

    NASA Astrophysics Data System (ADS)

    Layne, G. D.; Shimizu, N.

    2002-12-01

    The MIT-Brown-Harvard Regional Ion Microprobe Facility was one of the earliest multi-user facilities enabled by Dan Weill's Instrumentation and Facilities Program - and began with the delivery of a Cameca IMS 3f ion microprobe to MIT in 1978. The Northeast National Ion Microprobe Facility (NENIMF) is the direct descendant of this original facility. Now housed at WHOI, the facility incorporates both the original IMS 3f, and a new generation, high transmission-high resolution instrument - the Cameca IMS 1270. Purchased with support from NSF, and from a consortium of academic institutions in the Northeast (The American Museum of Natural History, Brown University, The Lamont-Doherty Earth Observatory, MIT, Rensselaer Polytechnic Institute, WHOI) - this latest instrument was delivered and installed during 1996. NENIMF continues to be supported by NSF EAR I&F as a multi-user facility for geochemical research. Work at NENIMF has extended the original design strength of the IMS 1270 for microanalytical U-Pb zircon geochronology to a wide variety of novel and improved techniques for geochemical research. Isotope microanalysis for studies in volcanology and petrology is currently the largest single component of facility activity. This includes the direct measurement of Pb isotopes in melt inclusions, an application developed at NENIMF, which is making an increasingly significant contribution to our understanding of basalt petrogenesis. This same technique has also been extended to the determination of Pb isotopes in detrital feldspar grains, for the study of sedimentary provenance and tectonics of the Himalayas and other terrains. The determination of δ11B in volcanic melt inclusions has also proven to be a powerful tool in the modeling of subduction-related magmatism. The recent development of δ34S and δ37Cl determination in glasses is being applied to studies of the behavior of these volatile elements in both natural and experimental systems. Other recent undertakings

  13. Mechanochemically Active Soft Robots.

    PubMed

    Gossweiler, Gregory R; Brown, Cameron L; Hewage, Gihan B; Sapiro-Gheiler, Eitan; Trautman, William J; Welshofer, Garrett W; Craig, Stephen L

    2015-10-14

    The functions of soft robotics are intimately tied to their form-channels and voids defined by an elastomeric superstructure that reversibly stores and releases mechanical energy to change shape, grip objects, and achieve complex motions. Here, we demonstrate that covalent polymer mechanochemistry provides a viable mechanism to convert the same mechanical potential energy used for actuation in soft robots into a mechanochromic, covalent chemical response. A bis-alkene functionalized spiropyran (SP) mechanophore is cured into a molded poly(dimethylsiloxane) (PDMS) soft robot walker and gripper. The stresses and strains necessary for SP activation are compatible with soft robot function. The color change associated with actuation suggests opportunities for not only new color changing or camouflaging strategies, but also the possibility for simultaneous activation of latent chemistry (e.g., release of small molecules, change in mechanical properties, activation of catalysts, etc.) in soft robots. In addition, mechanochromic stress mapping in a functional robotic device might provide a useful design and optimization tool, revealing spatial and temporal force evolution within the robot in a way that might be coupled to autonomous feedback loops that allow the robot to regulate its own activity. The demonstration motivates the simultaneous development of new combinations of mechanophores, materials, and soft, active devices for enhanced functionality.

  14. Multiuser virtual worlds in healthcare education: A systematic review.

    PubMed

    Liaw, Sok Ying; Carpio, Guiller Augustin C; Lau, Ying; Tan, Seng Chee; Lim, Wee Shiong; Goh, Poh Sun

    2018-06-01

    The use of multiuser virtual worlds (MUVWs) for collaborative learning has generated interest among healthcare educators. Published evidence to support its use is growing, but none has synthesized the evidence to guide future work. This study sought to provide a comprehensive and systematic evaluation of MUVWs in healthcare education. A systematic review METHODS: A systematic search of five databases including CINAHL, Cochrane library, EMBASE, PubMed, and Scopus, was conducted from inception up to January 2017. Two independent researchers selected studies that met the inclusion criteria and assessed for methodological quality using the Medical Education Research Study Quality Instrument (MERSQI). A total of 18 studies were reviewed and their data were synthesized narratively using a 3-P model (presage-process-product). Average scores in the MERSQI for methodological quality are 10/18, which is modest. A rally by the government or professional bodies towards more collaborative working among healthcare professionals is a key driver behind implementing MUVWs. Funding is important for its development and evaluation. Team training in acute care and communication training were the most frequent learning objectives, and predominant learning activities include practice on simulation scenario and debriefing. Two-thirds of the studies did not explain their theoretical framework that underpinned their design and implementation of MUVWs. While MUVWs in healthcare education is generally well-received, learning outcomes remain inconclusive. Despite a growth of studies on the use of MUVW in healthcare education, there is a need for more understanding of the application of theories to inform the learning activities. Therefore, we suggest educators to incorporate a theoretical model to explain the learning processes behind MUVWs. To improve the quality of evidence, we call for researchers to employ a more rigorous and broader approach to evaluation that explicates longer

  15. Fast-moving soft electronic fish

    PubMed Central

    Li, Tiefeng; Li, Guorui; Liang, Yiming; Cheng, Tingyu; Dai, Jing; Yang, Xuxu; Liu, Bangyuan; Zeng, Zedong; Huang, Zhilong; Luo, Yingwu; Xie, Tao; Yang, Wei

    2017-01-01

    Soft robots driven by stimuli-responsive materials have unique advantages over conventional rigid robots, especially in their high adaptability for field exploration and seamless interaction with humans. The grand challenge lies in achieving self-powered soft robots with high mobility, environmental tolerance, and long endurance. We are able to advance a soft electronic fish with a fully integrated onboard system for power and remote control. Without any motor, the fish is driven solely by a soft electroactive structure made of dielectric elastomer and ionically conductive hydrogel. The electronic fish can swim at a speed of 6.4 cm/s (0.69 body length per second), which is much faster than previously reported untethered soft robotic fish driven by soft responsive materials. The fish shows consistent performance in a wide temperature range and permits stealth sailing due to its nearly transparent nature. Furthermore, the fish is robust, as it uses the surrounding water as the electric ground and can operate for 3 hours with one single charge. The design principle can be potentially extended to a variety of flexible devices and soft robots. PMID:28435879

  16. Periodontal Ligament Entheses and their Adaptive Role in the Context of Dentoalveolar Joint Function

    PubMed Central

    Lin, Jeremy D.; Jang, Andrew T.; Kurylo, Michael P.; Hurng, Jonathan; Yang, Feifei; Yang, Lynn; Pal, Arvin; Chen, Ling; Ho, Sunita P.

    2017-01-01

    Objectives The dynamic bone-periodontal ligament (PDL)-tooth fibrous joint consists of two adaptive functionally graded interfaces (FGI), the PDL-bone and PDL-cementum that respond to mechanical strain transmitted during mastication. In general, from a materials and mechanics perspective, FGI prevent catastrophic failure during prolonged cyclic loading. This review is a discourse of results gathered from literature to illustrate the dynamic adaptive nature of the fibrous joint in response to physiologic and pathologic simulated functions, and experimental tooth movement. Methods Historically, studies have investigated soft to hard tissue transitions through analytical techniques that provided insights into structural, biochemical, and mechanical characterization methods. Experimental approaches included two dimensional to three dimensional advanced in situ imaging and analytical techniques. These techniques allowed mapping and correlation of deformations to physicochemical and mechanobiological changes within volumes of the complex subjected to concentric and eccentric loading regimes respectively. Results Tooth movement is facilitated by mechanobiological activity at the interfaces of the fibrous joint and generates elastic discontinuities at these interfaces in response to eccentric loading. Both concentric and eccentric loads mediated cellular responses to strains, and prompted self-regulating mineral forming and resorbing zones that in turn altered the functional space of the joint. Significance A multiscale biomechanics and mechanobiology approach is important for correlating joint function to tissue-level strain-adaptive properties with overall effects on joint form as related to physiologic and pathologic functions. Elucidating the shift in localization of biomolecules specifically at interfaces during development, function, and therapeutic loading of the joint is critical for developing “functional regeneration and adaptation” strategies with an

  17. Simple Ontology Format (SOFT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorokine, Alexandre

    2011-10-01

    Simple Ontology Format (SOFT) library and file format specification provides a set of simple tools for developing and maintaining ontologies. The library, implemented as a perl module, supports parsing and verification of the files in SOFt format, operations with ontologies (adding, removing, or filtering of entities), and converting of ontologies into other formats. SOFT allows users to quickly create ontologies using only a basic text editor, verify it, and portray it in a graph layout system using customized styles.

  18. Tuberculous osteomyelitis/arthritis of the first costo-clavicular joint and sternum

    PubMed Central

    Patel, Prasan; Gray, Robin R

    2014-01-01

    A young Somali immigrant presents with a two-year history of a large, firm, painful right anterolateral chest wall sternal mass. The patient denied any history of trauma or infection at the site and did not have a fever, erythematous lesion at the site, clubbing, or lymphadenopathy. A lateral chest radiograph demonstrated a low density mass isolated to the subcutaneous soft tissue overlying the sternum, ribs and clavicle. Computed tomography (CT) with contrast demonstrated a cystic lesion in the right anterolateral chest wall deep to the pectoralis muscle. Enhanced CT of the chest demonstrated sclerosis and destruction of the rib and costochondral joint and manubrio-sternal joint narrowing. Ultrasound-guided biopsy and aspiration returned 500 cc of purulent, cloudy yellow, foul-smelling fluid. Acid-fact bacilli stain and the nucleic acid amplification test identified and confirmed Mycobacterium tuberculosis. A diagnosis of tuberculous osteomyelitis/septic arthritis was made and antibiotic coverage for tuberculosis was initiated. PMID:25550999

  19. Tuberculous osteomyelitis/arthritis of the first costo-clavicular joint and sternum.

    PubMed

    Patel, Prasan; Gray, Robin R

    2014-12-28

    A young Somali immigrant presents with a two-year history of a large, firm, painful right anterolateral chest wall sternal mass. The patient denied any history of trauma or infection at the site and did not have a fever, erythematous lesion at the site, clubbing, or lymphadenopathy. A lateral chest radiograph demonstrated a low density mass isolated to the subcutaneous soft tissue overlying the sternum, ribs and clavicle. Computed tomography (CT) with contrast demonstrated a cystic lesion in the right anterolateral chest wall deep to the pectoralis muscle. Enhanced CT of the chest demonstrated sclerosis and destruction of the rib and costochondral joint and manubrio-sternal joint narrowing. Ultrasound-guided biopsy and aspiration returned 500 cc of purulent, cloudy yellow, foul-smelling fluid. Acid-fact bacilli stain and the nucleic acid amplification test identified and confirmed Mycobacterium tuberculosis. A diagnosis of tuberculous osteomyelitis/septic arthritis was made and antibiotic coverage for tuberculosis was initiated.

  20. Glenoid labrum ossification and mechanical restriction of joint motion: extraosseous manifestations of melorheostosis.

    PubMed

    Subhas, N; Sundaram, M; Bauer, T W; Seitz, W H; Recht, M P

    2008-02-01

    We report a case of a 47-year-old man who presented with progressive loss of motion and pain in the right shoulder. Radiographs of the shoulder demonstrated dense ossification in the glenoid and humeral head with extension into the periarticular soft tissues. CT and MRI scans confirmed the radiographic findings and also revealed ossification of the glenoid labrum. A radiographic diagnosis of melorheostosis, an uncommon benign sclerosing bone dysplasia, was made. Because of the patient's severe symptomatology, he underwent total shoulder arthroplasty. Histological analysis of the resected masses was consistent with melorheostosis with a few areas covered by a cartilage cap. This case illustrates several uncommon but important features of melorheostosis, including mechanical obstruction of joint motion requiring joint replacement, ossification of the glenoid labrum, and cartilage-covering portions of the intra-articular masses, not to be confused with cartilage-producing tumors.

  1. Preparing soft-bodied arthropods for microscope examination: Soft Scales (Insecta: Hemiptera: Coccidae)

    USDA-ARS?s Scientific Manuscript database

    Proper identification of soft scales (Hemiptera:Coccidae) requires preparation of the specimen on a microscope slide. This training video provides visual instruction on how to prepare soft scale specimens on microscope slides for examination and identification. Steps ranging from collection, speci...

  2. Japanese plan for SSF utilization

    NASA Technical Reports Server (NTRS)

    Mizuno, Toshio

    1992-01-01

    The Japanese Experiment Module (JEM) program has made significant progress. The JEM preliminary design review was completed in July 1992; construction of JEM operation facilities has begun; and the micro-G airplane, drop shaft, and micro-G experiment rocket are all operational. The national policy for JEM utilization was also established. The Space Experiment Laboratory (SEL) opened in June '92 and will function as a user support center. Eight JEM multiuser facilities are in phase B, and scientific requirements are being defined for 17 candidate multiuser facilities. The National Joint Research Program is about to start. Precursor missions and early Space Station utilization activities are being defined. This paper summarizes the program in outline and graphic form.

  3. Development of a soft-soldering system for aluminum

    NASA Astrophysics Data System (ADS)

    Falke, W. L.; Lee, A. Y.; Neumeier, L. A.

    1983-03-01

    The method employs application of a thin nickel copper alloy coating to the substrate, which enables the tin lead solders to wet readily and spread over the areas to be joined. The aluminum substrate is mechanically or chemically cleaned to facilitate bonding to a minute layer of zinc that is subsequently applied, with an electroless zincate solution. The nickel copper alloy (30 to 70 pct Ni) coating is then applied electrolytically over the zinc, using immersion cell or brush coating techniques. Development of acetate electrolytes has permitted deposition of the proper alloys coatings. The coated areas can then be readily joined with conventional tin lead solders and fluxs. The joints so formed are ductile, strong, and relatively corrosion resistant, and exhibit strengths equivalent to those formed on copper and brass when the same solders and fluxes are used. The method has also been employed to soft solder magnesium alloys.

  4. Threshold and Jet Radius Joint Resummation for Single-Inclusive Jet Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xiaohui; Moch, Sven -Olaf; Ringer, Felix

    Here, we present the first threshold and jet radius jointly resummed cross section for single-inclusive hadronic jet production. We work at next-to-leading logarithmic accuracy and our framework allows for a systematic extension beyond the currently achieved precision. Long-standing numerical issues are overcome by performing the resummation directly in momentum space within soft collinear effective theory. We present the first numerical results for the LHC and observe an improved description of the available data. Our results are of immediate relevance for LHC precision phenomenology including the extraction of parton distribution functions and the QCD strong coupling constant.

  5. Open Dislocation of the High Ankle Joint After Fibular Graft Harvesting.

    PubMed

    Anđelković, Slađana Z; Vučković, Čedo Đ; Palibrk, Tomislav D; Milutinović, Suzana M; Bumbaširević, Marko Ž

    2015-01-01

    The free microvascular fibula and soft tissue transfer has become a widely used method for reconstruction of different regions. Donor site morbidity for free fibula microvascular flaps has generally been reported to be low, or at least acceptable. We describe the case of a patient who underwent vascularized free fibula graft harvest for mandibular reconstruction. After 21 months, he had sustained an open dislocation of the left high ankle joint during recreational sports activity. We did not found such case in the published data. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Threshold and Jet Radius Joint Resummation for Single-Inclusive Jet Production

    DOE PAGES

    Liu, Xiaohui; Moch, Sven -Olaf; Ringer, Felix

    2017-11-20

    Here, we present the first threshold and jet radius jointly resummed cross section for single-inclusive hadronic jet production. We work at next-to-leading logarithmic accuracy and our framework allows for a systematic extension beyond the currently achieved precision. Long-standing numerical issues are overcome by performing the resummation directly in momentum space within soft collinear effective theory. We present the first numerical results for the LHC and observe an improved description of the available data. Our results are of immediate relevance for LHC precision phenomenology including the extraction of parton distribution functions and the QCD strong coupling constant.

  7. Soft Tissue Sarcoma—Patient Version

    Cancer.gov

    Soft tissue sarcoma is a cancer that starts in soft tissues like muscle, tendons, fat, lymph vessels, blood vessels, and nerves. These cancers can develop anywhere in the body but are found mostly in the arms, legs, chest, and abdomen. Start here to find information on soft tissue sarcoma treatment and research.

  8. Soft bioelectronics using nanomaterials

    NASA Astrophysics Data System (ADS)

    Lee, Hyunjae; Kim, Dae-Hyeong

    2016-09-01

    Recently, soft bioelectronics has attracted significant attention because of its potential applications in biointegrated healthcare devices and minimally invasive surgical tools. Mechanical mismatch between conventional electronic/optoelectronic devices and soft human tissues/organs, however, causes many challenges in materials and device designs of bio-integrated devices. Intrinsically soft hybrid materials comprising twodimensional nanomaterials are utilized to solve these issues. In this paper, we describe soft bioelectronic devices based on graphene synthesized by a chemical vapor deposition process. These devices have unique advantages over rigid electronics, particularly in biomedical applications. The functionalized graphene is hybridized with other nanomaterials and fabricated into high-performance sensors and actuators toward wearable and minimally invasive healthcare devices. Integrated bioelectronic systems constructed using these devices solve pending issues in clinical medicine while providing new opportunities in personalized healthcare.

  9. Role of intraoperative varus stress test for lateral soft tissue release during chevron bunion procedure.

    PubMed

    Kim, Hyong-Nyun; Suh, Dong-Hyun; Hwang, Pil-Sung; Yu, Sun-O; Park, Yong-Wook

    2011-04-01

    The purpose of this study was to evaluate the clinical results of distal chevron osteotomy performed in conjunction with selective lateral soft tissue release. The criterion for doing a lateral soft tissue release was assessed by determining the ease and completeness of passive hallux valgus correction at the time of surgery. Between August 2005 and November 2007, 48 feet in 43 patients classified as having mild to moderate hallux valgus were retrospectively studied. Distal chevron osteotomy without lateral soft tissue release was performed in 26 cases (Group 1) when passive correction of the hallux valgus deformity was possible. Distal chevron osteotomy with lateral soft tissue release was performed in 22 cases (Group 2) when passive correction was not possible. Average followup was 23 (range, 12 to 28) months. Clinical results were assessed using radiographic parameters [hallux valgus angle (HVA), first and second intermetatarsal angle (1,2 IMA)], AOFAS scale and patient's subjective satisfaction. For Group 1: the average correction of HVA was 12.8 degrees, the average correction of IMA was 4.7 degrees, and the AOFAS score improved an average of 29.2 points at the last followup. Thirteen patients were very satisfied and ten patients were satisfied with the results. No patient was dissatisfied. For Group 2: the average correction of HVA was 19.1 degrees, the average correction of IMA was 7 degrees and AOFAS score improved at an average of 31.8 points at the last followup. Twelve patients were very satisfied, seven patients were satisfied and one patient, who had stiffness of the first metatarsophalangeal joint, was dissatisfied with the result. Distal chevron osteotomy with selective lateral soft tissue release based on the ability to passively correct the hallux valgus deformity lead to safe and stable correction.

  10. Concept design theory and model for multi-use space facilities: Analysis of key system design parameters through variance of mission requirements

    NASA Astrophysics Data System (ADS)

    Reynerson, Charles Martin

    This research has been performed to create concept design and economic feasibility data for space business parks. A space business park is a commercially run multi-use space station facility designed for use by a wide variety of customers. Both space hardware and crew are considered as revenue producing payloads. Examples of commercial markets may include biological and materials research, processing, and production, space tourism habitats, and satellite maintenance and resupply depots. This research develops a design methodology and an analytical tool to create feasible preliminary design information for space business parks. The design tool is validated against a number of real facility designs. Appropriate model variables are adjusted to ensure that statistical approximations are valid for subsequent analyses. The tool is used to analyze the effect of various payload requirements on the size, weight and power of the facility. The approach for the analytical tool was to input potential payloads as simple requirements, such as volume, weight, power, crew size, and endurance. In creating the theory, basic principles are used and combined with parametric estimation of data when necessary. Key system parameters are identified for overall system design. Typical ranges for these key parameters are identified based on real human spaceflight systems. To connect the economics to design, a life-cycle cost model is created based upon facility mass. This rough cost model estimates potential return on investments, initial investment requirements and number of years to return on the initial investment. Example cases are analyzed for both performance and cost driven requirements for space hotels, microgravity processing facilities, and multi-use facilities. In combining both engineering and economic models, a design-to-cost methodology is created for more accurately estimating the commercial viability for multiple space business park markets.

  11. Bidirectional and Multi-User Telerehabilitation System: Clinical Effect on Balance, Functional Activity, and Satisfaction in Patients with Chronic Stroke Living in Long-Term Care Facilities

    PubMed Central

    Lin, Kwan-Hwa; Chen, Chin-Hsing; Chen, You-Yin; Huang, Wen-Tzeng; Lai, Jin-Shin; Yu, Shang-Ming; Chang, Yuan-Jen

    2014-01-01

    Background The application of internet technology for telerehabilitation in patients with stroke has developed rapidly. Objective The current study aimed to evaluate the effect of a bidirectional and multi-user telerehabilitation system on balance and satisfaction in patients with chronic stroke living in long-term care facilities (LTCFs). Method This pilot study used a multi-site, blocked randomization design. Twenty-four participants from three LTCFs were recruited, and the participants were randomly assigned into the telerehabilitation (Tele) and conventional therapy (Conv) groups within each LTCF. Tele group received telerehabilitation but the Conv group received conventional therapy with two persons in each group for three sessions per week and for four weeks. The outcome measures included Berg Balance Scale (BBS), Barthel Index (BI), and the telerehabilitation satisfaction of the participants. Setting A telerehabilitation system included “therapist end” in a laboratory, and the “client end” in LTCFs. The conventional therapy was conducted in LTCFs. Results Training programs conducted for both the Tele and Conv groups showed significant effects within groups on the participant BBS as well as the total and self-care scores of BI. No significant difference between groups could be demonstrated. The satisfaction of participants between the Tele and the Conv groups also did not show significant difference. Conclusions This pilot study indicated that the multi-user telerehabilitation program is feasible for improving the balance and functional activity similar to conventional therapy in patients with chronic stroke living in LTCFs. PMID:25019632

  12. Performance of a novel LED lamp arrangement to reduce SNR fluctuation for multi-user visible light communication systems.

    PubMed

    Wang, Zixiong; Yu, Changyuan; Zhong, Wen-De; Chen, Jian; Chen, Wei

    2012-02-13

    This paper investigates the performance of our recently proposed LED lamp arrangement to reduce the SNR fluctuation from different locations in the room for multi-user visible light communications. The LED lamp arrangement consists of 4 LED lamps positioned in the corners and 12 LED lamps spread evenly on a circle. Our studies show that the SNR fluctuation under such a LED lamp arrangement is reduced from 14.5 dB to 0.9 dB, which guarantees that users can obtain almost identical communication quality, regardless of their locations. After time domain zero-forcing (ZF) equalization, the BER performances and channel capacities of 100-Mbit/s and 200-Mbit/s bipolar on-off-keying (OOK) signal with most significant inter-symbol interference (ISI) are very close to that of the channel without any ISI caused by this LED lamp arrangement.

  13. Exploring the Use of Individualized, Reflective Guidance In an Educational Multi-User Virtual Environment

    NASA Astrophysics Data System (ADS)

    Nelson, Brian C.

    2007-02-01

    This study examines the patterns of use and potential impact of individualized, reflective guidance in an educational Multi-User Virtual Environment (MUVE). A guidance system embedded within a MUVE-based scientific inquiry curriculum was implemented with a sample of middle school students in an exploratory study investigating (a) whether access to the guidance system was associated with improved learning, (b) whether students viewing more guidance messages saw greater improvement on content tests than those viewing less, and (c) whether there were any differences in guidance use among boys and girls. Initial experimental findings showed that basic access to individualized guidance used with a MUVE had no measurable impact on learning. However, post-hoc exploratory analyses indicated that increased use of the system among those with access to it was positively associated with content test score gains. In addition, differences were found in overall learning outcomes by gender and in patterns of guidance use by boys and girls, with girls outperforming boys across a spectrum of guidance system use. Based on these exploratory findings, the paper suggests design guidelines for the development of guidance systems embedded in MUVEs and outlines directions for further research.

  14. Computer Simulation and Field Experiment for Downlink Multiuser MIMO in Mobile WiMAX System.

    PubMed

    Yamaguchi, Kazuhiro; Nagahashi, Takaharu; Akiyama, Takuya; Matsue, Hideaki; Uekado, Kunio; Namera, Takakazu; Fukui, Hiroshi; Nanamatsu, Satoshi

    2015-01-01

    The transmission performance for a downlink mobile WiMAX system with multiuser multiple-input multiple-output (MU-MIMO) systems in a computer simulation and field experiment is described. In computer simulation, a MU-MIMO transmission system can be realized by using the block diagonalization (BD) algorithm, and each user can receive signals without any signal interference from other users. The bit error rate (BER) performance and channel capacity in accordance with modulation schemes and the number of streams were simulated in a spatially correlated multipath fading environment. Furthermore, we propose a method for evaluating the transmission performance for this downlink mobile WiMAX system in this environment by using the computer simulation. In the field experiment, the received power and downlink throughput in the UDP layer were measured on an experimental mobile WiMAX system developed in Azumino City in Japan. In comparison with the simulated and experimented results, the measured maximum throughput performance in the downlink had almost the same performance as the simulated throughput. It was confirmed that the experimental mobile WiMAX system for MU-MIMO transmission successfully increased the total channel capacity of the system.

  15. Computer Simulation and Field Experiment for Downlink Multiuser MIMO in Mobile WiMAX System

    PubMed Central

    Yamaguchi, Kazuhiro; Nagahashi, Takaharu; Akiyama, Takuya; Matsue, Hideaki; Uekado, Kunio; Namera, Takakazu; Fukui, Hiroshi; Nanamatsu, Satoshi

    2015-01-01

    The transmission performance for a downlink mobile WiMAX system with multiuser multiple-input multiple-output (MU-MIMO) systems in a computer simulation and field experiment is described. In computer simulation, a MU-MIMO transmission system can be realized by using the block diagonalization (BD) algorithm, and each user can receive signals without any signal interference from other users. The bit error rate (BER) performance and channel capacity in accordance with modulation schemes and the number of streams were simulated in a spatially correlated multipath fading environment. Furthermore, we propose a method for evaluating the transmission performance for this downlink mobile WiMAX system in this environment by using the computer simulation. In the field experiment, the received power and downlink throughput in the UDP layer were measured on an experimental mobile WiMAX system developed in Azumino City in Japan. In comparison with the simulated and experimented results, the measured maximum throughput performance in the downlink had almost the same performance as the simulated throughput. It was confirmed that the experimental mobile WiMAX system for MU-MIMO transmission successfully increased the total channel capacity of the system. PMID:26421311

  16. Multi-user quantum key distribution with entangled photons from an AlGaAs chip

    NASA Astrophysics Data System (ADS)

    Autebert, C.; Trapateau, J.; Orieux, A.; Lemaître, A.; Gomez-Carbonell, C.; Diamanti, E.; Zaquine, I.; Ducci, S.

    2016-12-01

    In view of real-world applications of quantum information technologies, the combination of miniature quantum resources with existing fibre networks is a crucial issue. Among such resources, on-chip entangled photon sources play a central role for applications spanning quantum communications, computing and metrology. Here, we use a semiconductor source of entangled photons operating at room temperature in conjunction with standard telecom components to demonstrate multi-user quantum key distribution, a core protocol for securing communications in quantum networks. The source consists of an AlGaAs chip-emitting polarisation entangled photon pairs over a large bandwidth in the main telecom band around 1550 nm without the use of any off-chip compensation or interferometric scheme; the photon pairs are directly launched into a dense wavelength division multiplexer (DWDM) and secret keys are distributed between several pairs of users communicating through different channels. We achieve a visibility measured after the DWDM of 87% and show long-distance key distribution using a 50-km standard telecom fibre link between two network users. These results illustrate a promising route to practical, resource-efficient implementations adapted to quantum network infrastructures.

  17. A three-dimensional back-analysis of the collapse of an underground cavity in soft rocks

    NASA Astrophysics Data System (ADS)

    Fazio, Nunzio Luciano; Lollino, Piernicola; Perrotti, Michele; Parise, Mario; Bonamini, Marco; Di Maggio, Cipriano; Madonia, Giuliana; Vattano, Marco

    2016-04-01

    Anthropogenic sinkholes have recently occurred in built-up areas of Sicily (southern Italy) and are generally associated with the presence of ancient underground quarries for the extraction of soft calcarenite rock, used as building material. These quarries were poorly excavated and then were abandoned in the following decades; urban expansion has recently enlarged to involve the areas affected by presence of the cavities, so that the likely collapse of the underground systems poses serious risks to people, buildings and infrastructures. The present work focuses on the case of the town of Marsala, where in 2003 a sinkhole opened at the outskirts of town, near peri-urban buildings. Field surveys, structural analysis of the joint networks in the rock mass and numerical modeling were carried out in order to investigate the most significant factors responsible of the instability processes of the underground quarry. In particular, a geotechnical three-dimensional model has been defined based on in-situ measurements and surveys. The FEM analyses have been performed with the code Plaxis-3D, by using initially the Mohr-Coulomb elasto-plastic model and then assessing the influence of the joint systems on the rock-mass stability with a jointed rock anisotropic model. Discrete planar bands have been also used to simulate the effect of specific joints, as an alternative to the jointed rock model. The results are in good agreement with the failure mechanism generated during the 2003 sinkhole event, and confirm that reliable analyses of these problems requires 3-D sophisticated tools.

  18. [Anatomy typological and clinical parallels in case of disturbance of soft tissue formations of shoulder girdle].

    PubMed

    Volkov, A V; Shutov, Iu M; Shutova, M Z

    2012-01-01

    The influence of anthropology on topographical anatomical structure peculiarities of soft tissue formations of shoulder girdle has been investigated. The dependence of anatomical structure and topography of muscles, ligaments, tendon sheaths, synovial bursae, rotator cuffs on patient's body constitution type has been examined. The influence of a somatotype on topical damage of soft tissue structures of shoulder girdle has been proved. The so-called "holes" or weak areas, joint capsules, places where ligaments attach to bones and cartilages, where vascular formations also take place have been revealed. It is in these areas that degenerative inflammatory process begins. First of all this process influences hemolymph circulation, then it results in disturbance in production and resorption of synovial fluid and causes destructive processes in ligaments, tendons and osteochondral tissue. Due to research the ability to conduct differential diagnosis has been determined, methods of modality treatment and prevention of periarticular tissue diseases have been optimized.

  19. Nanobiotechnology: soft lithography.

    PubMed

    Mele, Elisa; Pisignano, Dario

    2009-01-01

    An entirely new scientific and technological area has been born from the combination of nanotechnology and biology: nanobiotechnology. Such a field is primed especially by the strong potential synergy enabled by the integration of technologies, protocols, and investigation methods, since, while biomolecules represent functional nanosystems interesting for nanotechnology, micro- and nano-devices can be very useful instruments for studying biological materials. In particular, the research of new approaches for manipulating matter and fabricating structures with micrometre- and sub-micrometre resolution has determined the development of soft lithography, a new set of non-photolithographic patterning techniques applied to the realization of selective proteins and cells attachment, microfluidic circuits for protein and DNA chips, and 3D scaffolds for tissue engineering. Today, soft lithographies have become an asset of nanobiotechnology. This Chapter examines the biological applications of various soft lithographic techniques, with particular attention to the main general features of soft lithography and of materials commonly employed with these methods. We present approaches particularly suitable for biological materials, such as microcontact printing (muCP) and microfluidic lithography, and some key micro- and nanobiotechnology applications, such as the patterning of protein and DNA microarrays and the realization of microfluidic-based analytical devices.

  20. Soft tissue modelling with conical springs.

    PubMed

    Omar, Nadzeri; Zhong, Yongmin; Jazar, Reza N; Subic, Aleksandar; Smith, Julian; Shirinzadeh, Bijan

    2015-01-01

    This paper presents a new method for real-time modelling soft tissue deformation. It improves the traditional mass-spring model with conical springs to deal with nonlinear mechanical behaviours of soft tissues. A conical spring model is developed to predict soft tissue deformation with reference to deformation patterns. The model parameters are formulated according to tissue deformation patterns and the nonlinear behaviours of soft tissues are modelled with the stiffness variation of conical spring. Experimental results show that the proposed method can describe different tissue deformation patterns using one single equation and also exhibit the typical mechanical behaviours of soft tissues.

  1. Knee Kinematics Estimation Using Multi-Body Optimisation Embedding a Knee Joint Stiffness Matrix: A Feasibility Study

    PubMed Central

    Richard, Vincent; Lamberto, Giuliano; Lu, Tung-Wu; Cappozzo, Aurelio; Dumas, Raphaël

    2016-01-01

    The use of multi-body optimisation (MBO) to estimate joint kinematics from stereophotogrammetric data while compensating for soft tissue artefact is still open to debate. Presently used joint models embedded in MBO, such as mechanical linkages, constitute a considerable simplification of joint function, preventing a detailed understanding of it. The present study proposes a knee joint model where femur and tibia are represented as rigid bodies connected through an elastic element the behaviour of which is described by a single stiffness matrix. The deformation energy, computed from the stiffness matrix and joint angles and displacements, is minimised within the MBO. Implemented as a “soft” constraint using a penalty-based method, this elastic joint description challenges the strictness of “hard” constraints. In this study, estimates of knee kinematics obtained using MBO embedding four different knee joint models (i.e., no constraints, spherical joint, parallel mechanism, and elastic joint) were compared against reference kinematics measured using bi-planar fluoroscopy on two healthy subjects ascending stairs. Bland-Altman analysis and sensitivity analysis investigating the influence of variations in the stiffness matrix terms on the estimated kinematics substantiate the conclusions. The difference between the reference knee joint angles and displacements and the corresponding estimates obtained using MBO embedding the stiffness matrix showed an average bias and standard deviation for kinematics of 0.9±3.2° and 1.6±2.3 mm. These values were lower than when no joint constraints (1.1±3.8°, 2.4±4.1 mm) or a parallel mechanism (7.7±3.6°, 1.6±1.7 mm) were used and were comparable to the values obtained with a spherical joint (1.0±3.2°, 1.3±1.9 mm). The study demonstrated the feasibility of substituting an elastic joint for more classic joint constraints in MBO. PMID:27314586

  2. Controversies In The Surgical Management Of Shoulder Instability: Associated Soft Tissue Procedures.

    PubMed

    Marco, Santos Moros; Lafuente, José Luis Ávila; Ibán, Miguel Angel Ruiz; Heredia, Jorge Diaz

    2017-01-01

    The glenohumeral joint is a ball-and-socket joint that is inherently unstable and thus, susceptible to dislocation. The traditional and most common anatomic finding is the Bankart lesion (anterior-inferior capsule labral complex avulsion), but there is a wide variety of anatomic alterations that can cause shoulder instability or may be present as a concomitant injury or in combination, including bone loss (glenoid or humeral head), complex capsule-labral tears, rotator cuff tears, Kim´s lesions (injuries to the posterior-inferior labrum) and rotator interval pathology. A review of articles related to shoulder anatomy and soft tissue procedures that are performed during shoulder instability arthroscopic management was conducted by querying the Pubmed database and conclusions and controversies regarding this injury were exposed. Due to the complex anatomy of the shoulder and the large range of movement of this joint, a wide variety of anatomic injuries and conditions can lead to shoulder instability, specially present in young population. Recognizing and treating all of them including Bankart repair, capsule-labral plicatures, SLAP repair, circumferential approach to pan-labral lesions, rotator interval closure, rotator cuff injuries and HAGL lesion repair is crucial to achieve the goal of a stable, full range of movement and not painful joint. Physicians must be familiarized with all the lesions involved in shoulder instability, and should be able to recognize and subsequently treat them to achieve the goal of a stable non-painful shoulder. Unrecognized or not treated lesions may result in recurrence of instability episodes and pain while overuse of some of the techniques previously described can lead to stiffness, thus the importance of an accurate diagnosis and treatment when facing a shoulder instability.

  3. Kinetic analysis of reactions of Si-based epoxy resins by near-infrared spectroscopy, 13C NMR and soft-hard modelling.

    PubMed

    Garrido, Mariano; Larrechi, Maria Soledad; Rius, F Xavier; Mercado, Luis Adolfo; Galià, Marina

    2007-02-05

    Soft- and hard-modelling strategy was applied to near-infrared spectroscopy data obtained from monitoring the reaction between glycidyloxydimethylphenyl silane, a silicon-based epoxy monomer, and aniline. On the basis of the pure soft-modelling approach and previous chemical knowledge, a kinetic model for the reaction was proposed. Then, multivariate curve resolution-alternating least squares optimization was carried out under a hard constraint, that compels the concentration profiles to fulfil the proposed kinetic model at each iteration of the optimization process. In this way, the concentration profiles of each species and the corresponding kinetic rate constants of the reaction, unpublished until now, were obtained. The results obtained were contrasted with 13C NMR. The joint interval test of slope and intercept for detecting bias was not significant (alpha=5%).

  4. Random Walk Graph Laplacian-Based Smoothness Prior for Soft Decoding of JPEG Images.

    PubMed

    Liu, Xianming; Cheung, Gene; Wu, Xiaolin; Zhao, Debin

    2017-02-01

    Given the prevalence of joint photographic experts group (JPEG) compressed images, optimizing image reconstruction from the compressed format remains an important problem. Instead of simply reconstructing a pixel block from the centers of indexed discrete cosine transform (DCT) coefficient quantization bins (hard decoding), soft decoding reconstructs a block by selecting appropriate coefficient values within the indexed bins with the help of signal priors. The challenge thus lies in how to define suitable priors and apply them effectively. In this paper, we combine three image priors-Laplacian prior for DCT coefficients, sparsity prior, and graph-signal smoothness prior for image patches-to construct an efficient JPEG soft decoding algorithm. Specifically, we first use the Laplacian prior to compute a minimum mean square error initial solution for each code block. Next, we show that while the sparsity prior can reduce block artifacts, limiting the size of the overcomplete dictionary (to lower computation) would lead to poor recovery of high DCT frequencies. To alleviate this problem, we design a new graph-signal smoothness prior (desired signal has mainly low graph frequencies) based on the left eigenvectors of the random walk graph Laplacian matrix (LERaG). Compared with the previous graph-signal smoothness priors, LERaG has desirable image filtering properties with low computation overhead. We demonstrate how LERaG can facilitate recovery of high DCT frequencies of a piecewise smooth signal via an interpretation of low graph frequency components as relaxed solutions to normalized cut in spectral clustering. Finally, we construct a soft decoding algorithm using the three signal priors with appropriate prior weights. Experimental results show that our proposal outperforms the state-of-the-art soft decoding algorithms in both objective and subjective evaluations noticeably.

  5. Mapping on complex neutrosophic soft expert sets

    NASA Astrophysics Data System (ADS)

    Al-Quran, Ashraf; Hassan, Nasruddin

    2018-04-01

    We introduce the mapping on complex neutrosophic soft expert sets. Further, we investigated the basic operations and other related properties of complex neutrosophic soft expert image and complex neutrosophic soft expert inverse image of complex neutrosophic soft expert sets.

  6. Soft-tissue tension total knee arthroplasty.

    PubMed

    Asano, Hiroshi; Hoshino, Akiho; Wilton, Tim J

    2004-08-01

    It is far from clear how best to define the proper strength of soft-tissue tensioning in total knee arthroplasty (TKA). We attached a torque driver to the Monogram balancer/tensor device and measured soft-tissue tension in full extension and 90 degrees flexion during TKA. In our surgical procedure, when we felt proper soft-tissue tension was being applied, the mean distraction force was noted to be 126N in extension and 121N in flexion. There was no significant correlation between soft-tissue tension and the postoperative flexion angle finally achieved. To the best of our knowledge, this is the first study to assess the actual distraction forces in relation to soft-tissue tension in TKA. Further study may reveal the most appropriate forces to achieve proper soft-tissue tension in the wide variety of circumstances presenting at knee arthroplasty.

  7. Palmar reconstruction of the triangular fibrocartilage complex for instability of the distal radioulnar joint: a biomechanical study.

    PubMed

    Kataoka, T; Moritomo, H; Omokawa, S; Iida, A; Wada, T; Aoki, M

    2013-06-01

    We developed a new triangular fibrocartilage complex reconstruction technique for distal radioulnar joint instability in which the palmar portion of the triangular fibrocartilage complex was predominantly reconstructed, and evaluated whether such reconstruction can restore stability of the distal radioulnar joint in seven fresh cadaver upper extremities. Distal radioulnar joint instability was induced by cutting all soft-tissue stabilizers around the distal ulna. Using a palmar approach, a palmaris longus tendon graft was sutured to the remnant of the palmar radioulnar and ulnocarpal ligaments. The graft was then passed through a bone tunnel created at the fovea and was sutured. Loads were applied to the radius, and dorsopalmar displacements of the radius relative to the ulna were measured using an electromagnetic tracking device in neutral rotation, 60° supination and 60° pronation. We compared the dorsopalmar displacements before sectioning, before reconstruction and after reconstruction. Dorsopalmar instability produced by sectioning significantly improved in all forearm positions after reconstruction.

  8. Soft Tissue Sarcoma—Health Professional Version

    Cancer.gov

    Soft tissue sarcomas are malignant tumors that arise in any of the mesodermal tissues of the extremities, trunk and retroperitoneum, or head and neck. Soft tissue sarcomas may be heterogeneous. Find evidence-based information on soft tissue sarcoma treatment and research.

  9. HiL simulation in biomechanics: a new approach for testing total joint replacements.

    PubMed

    Herrmann, Sven; Kaehler, Michael; Souffrant, Robert; Rachholz, Roman; Zierath, János; Kluess, Daniel; Mittelmeier, Wolfram; Woernle, Christoph; Bader, Rainer

    2012-02-01

    Instability of artificial joints is still one of the most prevalent reasons for revision surgery caused by various influencing factors. In order to investigate instability mechanisms such as dislocation under reproducible, physiologically realistic boundary conditions, a novel test approach is introduced by means of a hardware-in-the-loop (HiL) simulation involving a highly flexible mechatronic test system. In this work, the underlying concept and implementation of all required units is presented enabling comparable investigations of different total hip and knee replacements, respectively. The HiL joint simulator consists of two units: a physical setup composed of a six-axes industrial robot and a numerical multibody model running in real-time. Within the multibody model, the anatomical environment of the considered joint is represented such that the soft tissue response is accounted for during an instability event. Hence, the robot loads and moves the real implant components according to the information provided by the multibody model while transferring back the position and resisting moment recorded. Functionality of the simulator is proved by testing the underlying control principles, and verified by reproducing the dislocation process of a standard total hip replacement. HiL simulations provide a new biomechanical testing tool for analyzing different joint replacement systems with respect to their instability behavior under realistic movements and physiological load conditions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Histologic anatomy of the lesser metatarsophalangeal joint plantar plate.

    PubMed

    Gregg, J; Marks, P; Silberstein, M; Schneider, T; Kerr, J

    2007-03-01

    The plantar plate is the fibrocartilaginous structure that supports the ball of the foot, withstanding considerable compressive and tensile forces. This study describes the morphology of the plantar plate in order to understand its function and the pathologic disorders associated with it. Eight lesser metatarsophalangeal joint plantar plates from three soft-embalmed cadavers (74-92 years, two males, one female), and eight lesser metatarsophalangeal joint plantar plates from a fresh cadaver (19-year-old male) were obtained for histology assessment. Paraffin sections (10 microm) in the longitudinal and transverse planes were analyzed with bright-field and polarized light microscopy. The central plantar plate collagen bundles run in the longitudinal plane with varying degrees of undulation. The plantar plate borders run transversely and merge with collateral ligaments and the deep transverse intermetatarsal ligament. Bright-field microscopic evaluation shows the plantar aspect of the plantar plate becomes ligament-like the further distally it tapers, containing fewer chondrocytes, and a greater abundance of fibroblasts. The enthesis reveals longitudinal and interwoven collagen bundles entering the proximal phalanx with multiple interdigitations. Longer interdigitations centrally compared to the dorsal and plantar aspects suggest that the central fibers experience the greatest loads.

  11. Exploring the potential of polyurethane-based soft foam as cell-free scaffold for soft tissue regeneration.

    PubMed

    Gerges, Irini; Tamplenizza, Margherita; Martello, Federico; Recordati, Camilla; Martelli, Cristina; Ottobrini, Luisa; Tamplenizza, Mariacaterina; Guelcher, Scott A; Tocchio, Alessandro; Lenardi, Cristina

    2018-06-01

    Reconstructive treatment after trauma and tumor resection would greatly benefit from an effective soft tissue regeneration. The use of cell-free scaffolds for adipose tissue regeneration in vivo is emerging as an attractive alternative to tissue-engineered constructs, since this approach avoids complications due to cell manipulation and lack of synchronous vascularization. In this study, we developed a biodegradable polyurethane-based scaffold for soft tissue regeneration, characterized by an exceptional combination between softness and resilience. Exploring the potential as a cell-free scaffold required profound understanding of the impact of its intrinsic physico-chemical properties on the biological performance in vivo. We investigated the effect of the scaffold's hydrophilic character, degradation kinetics, and internal morphology on (i) the local inflammatory response and activation of MGCs (foreign body response); (ii) its ability to promote rapid vascularisation, cell infiltration and migration through the scaffold over time; and (iii) the grade of maturation of the newly formed tissue into vascularized soft tissue in a murine model. The study revealed that soft tissue regeneration in vivo proceeded by gradual infiltration of undifferentiated mesenchymal cells though the periphery toward the center of the scaffold, where the rapid formation of a functional and well-formed vascular network supported cell viability overtime. Exploring the potential of polyurethane-based soft foam as cell-free scaffold for soft tissue regeneration. In this work, we address the unmet need for synthetic functional soft tissue substitutes that provide adequate biological and mechanical support to soft tissue. We developed a series of flexible cross-linked polyurethane copolymer scaffolds with remarkable fatigue-resistance and tunable physico-chemical properties for soft tissue regeneration in vivo. Accordingly, we could extend the potential of this class of biomaterials, which was

  12. Leading multi-soft limits from scattering equations

    NASA Astrophysics Data System (ADS)

    Zlotnikov, Michael

    2017-10-01

    A Cachazo-He-Yuan (CHY) type formula is derived for the leading gluon, bi-adjoint scalar ϕ 3, Yang-Mills-scalar and non-linear sigma model m-soft factors S m in arbitrary dimension. The general formula is used to evaluate explicit examples for up to three soft legs analytically and up to four soft legs numerically via comparison with amplitude ratios under soft kinematics. A structural pattern for gluon m-soft factor is inferred and a simpler formula for its calculation is conjectured. In four dimensions, a Cachazo-Svrček-Witten (CSW) recursive procedure producing the leading m-soft gluon factor in spinor helicity formalism is developed as an alternative, and Britto-Cachazo-Feng-Witten (BCFW) recursion is used to obtain the leading four-soft gluon factor for all analytically distinct helicity configurations.

  13. Soft Decision Analyzer

    NASA Technical Reports Server (NTRS)

    Lansdowne, Chatwin; Steele, Glen; Zucha, Joan; Schlesinger, Adam

    2013-01-01

    We describe the benefit of using closed-loop measurements for a radio receiver paired with a counterpart transmitter. We show that real-time analysis of the soft decision output of a receiver can provide rich and relevant insight far beyond the traditional hard-decision bit error rate (BER) test statistic. We describe a Soft Decision Analyzer (SDA) implementation for closed-loop measurements on single- or dual- (orthogonal) channel serial data communication links. The analyzer has been used to identify, quantify, and prioritize contributors to implementation loss in live-time during the development of software defined radios. This test technique gains importance as modern receivers are providing soft decision symbol synchronization as radio links are challenged to push more data and more protocol overhead through noisier channels, and software-defined radios (SDRs) use error-correction codes that approach Shannon's theoretical limit of performance.

  14. Soft pneumatic grippers embedded with stretchable electroadhesion

    NASA Astrophysics Data System (ADS)

    Guo, J.; Elgeneidy, K.; Xiang, C.; Lohse, N.; Justham, L.; Rossiter, J.

    2018-05-01

    Current soft pneumatic grippers cannot robustly grasp flat materials and flexible objects on curved surfaces without distorting them. Current electroadhesive grippers, on the other hand, are difficult to actively deform to complex shapes to pick up free-form surfaces or objects. An easy-to-implement PneuEA gripper is proposed by the integration of an electroadhesive gripper and a two-fingered soft pneumatic gripper. The electroadhesive gripper was fabricated by segmenting a soft conductive silicon sheet into a two-part electrode design and embedding it in a soft dielectric elastomer. The two-fingered soft pneumatic gripper was manufactured using a standard soft lithography approach. This novel integration has combined the benefits of both the electroadhesive and soft pneumatic grippers. As a result, the proposed PneuEA gripper was not only able to pick-and-place flat and flexible materials such as a porous cloth but also delicate objects such as a light bulb. By combining two soft touch sensors with the electroadhesive, an intelligent and shape-adaptive PneuEA material handling system has been developed. This work is expected to widen the applications of both soft gripper and electroadhesion technologies.

  15. Ideal Theory in Semigroups Based on Intersectional Soft Sets

    PubMed Central

    Song, Seok Zun; Jun, Young Bae

    2014-01-01

    The notions of int-soft semigroups and int-soft left (resp., right) ideals are introduced, and several properties are investigated. Using these notions and the notion of inclusive set, characterizations of subsemigroups and left (resp., right) ideals are considered. Using the notion of int-soft products, characterizations of int-soft semigroups and int-soft left (resp., right) ideals are discussed. We prove that the soft intersection of int-soft left (resp., right) ideals (resp., int-soft semigroups) is also int-soft left (resp., right) ideals (resp., int-soft semigroups). The concept of int-soft quasi-ideals is also introduced, and characterization of a regular semigroup is discussed. PMID:25101310

  16. Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation

    PubMed Central

    Koh, Tze Hui; Cheng, Nicholas; Yap, Hong Kai; Yeow, Chen-Hua

    2017-01-01

    The provision of continuous passive, and intent-based assisted movements for neuromuscular training can be incorporated into a robotic elbow sleeve. The objective of this study is to propose the design and test the functionality of a soft robotic elbow sleeve in assisting flexion and extension of the elbow, both passively and using intent-based motion reinforcement. First, the elbow sleeve was developed, using elastomeric and fabric-based pneumatic actuators, which are soft and lightweight, in order to address issues of non-portability and poor alignment with joints that conventional robotic rehabilitation devices are faced with. Second, the control system was developed to allow for: (i) continuous passive actuation, in which the actuators will be activated in cycles, alternating between flexion and extension; and (ii) an intent-based actuation, in which user intent is detected by surface electromyography (sEMG) sensors attached to the biceps and triceps, and passed through a logic sequence to allow for flexion or extension of the elbow. Using this setup, the elbow sleeve was tested on six healthy subjects to assess the functionality of the device, in terms of the range of motion afforded by the device while in the continuous passive actuation. The results showed that the elbow sleeve is capable of achieving approximately 50% of the full range of motion of the elbow joint among all subjects. Next, further experiments were conducted to test the efficacy of the intent-based actuation on these healthy subjects. The results showed that all subjects were capable of achieving electromyography (EMG) control of the elbow sleeve. These preliminary results show that the elbow sleeve is capable of carrying out continuous passive and intent-based assisted movements. Further investigation of the clinical implementation of the elbow sleeve for the neuromuscular training of neurologically-impaired persons, such as stroke survivors, is needed. PMID:29118693

  17. Quantum key distribution in a multi-user network at gigahertz clock rates

    NASA Astrophysics Data System (ADS)

    Fernandez, Veronica; Gordon, Karen J.; Collins, Robert J.; Townsend, Paul D.; Cova, Sergio D.; Rech, Ivan; Buller, Gerald S.

    2005-07-01

    In recent years quantum information research has lead to the discovery of a number of remarkable new paradigms for information processing and communication. These developments include quantum cryptography schemes that offer unconditionally secure information transport guaranteed by quantum-mechanical laws. Such potentially disruptive security technologies could be of high strategic and economic value in the future. Two major issues confronting researchers in this field are the transmission range (typically <100km) and the key exchange rate, which can be as low as a few bits per second at long optical fiber distances. This paper describes further research of an approach to significantly enhance the key exchange rate in an optical fiber system at distances in the range of 1-20km. We will present results on a number of application scenarios, including point-to-point links and multi-user networks. Quantum key distribution systems have been developed, which use standard telecommunications optical fiber, and which are capable of operating at clock rates of up to 2GHz. They implement a polarization-encoded version of the B92 protocol and employ vertical-cavity surface-emitting lasers with emission wavelengths of 850 nm as weak coherent light sources, as well as silicon single-photon avalanche diodes as the single photon detectors. The point-to-point quantum key distribution system exhibited a quantum bit error rate of 1.4%, and an estimated net bit rate greater than 100,000 bits-1 for a 4.2 km transmission range.

  18. Radiosynoviorthesis of acromioclavicular joint using 169Er-citrate: prospective evaluation of efficacy.

    PubMed

    Vereb, Marika; Liepe, Knut; Fischer, Manfred; Kaliska, Lucia; Noskovicova, Lucia; Balogova, Sona

    2018-01-01

    There is a clinical need for therapeutic alternative in patients with persisting painful arthritis of AC-joint and failure of previous treatments. However, no radiopharmaceutical is currently explicitly approved for radiosynoviorthesis of acromioclavicular joint. The aim of our study was to prospectively assess the efficacy and safety of radiosynoviorthesis of acromioclavicular joint using erbium-169 citrate. Radiosynoviorthesis of acromioclavicular joint was performed in 51 consecutive patients (18 males, 33 females) mean age 64.3 (range 43.8-82.6, median 63.6) years with clinically confirmed arthritis of 85 acromioclavicular joints. The efficacy of RSO was reported by patients according to 10-step visual analogue scale of pain (VAS) (0 = no pain, 10 = most severe pain) at 6 months after radiosynoviorthesis and by ranking the global therapeutic effect of RSO in 4 categories (1 = the best effect, 4 = no change). To assess the variation of blood perfusion in treated joints, the efficacy of RSO was also evaluated by variation of target (acromioclavicular joint)/non-target (soft tissue) uptake ratio (T/NTR) of metylendiphosphonate (99mTc) measured as number of counts over region of interest on blood pool phase of two-phase bone scintigraphy performed before and 6 months after RSO. Radiosynoviorthesis was followed by significant decrease in VAS, mean - 3.1 (-47%). Excellent, good, moderate and bad response was observed in 57 (67%), 25 (29%), 1 (1%) and in 2 (2%) of acromioclavicular joints respectively. A significant correlation between decrease of T/NTR and variation of VAS in % (ρ = 0.532, p < 0.0001) and between T/NTR and subjective evaluation of therapeutic effect in scale 1-4 (ρ = 0.388, p = 0.0002) was observed. However, it was not possible to identify the cut-off value of relative decrease in T/NTR showing sufficient sensitivity and specificity to detect the therapeutic response. Results of this prospective study permit to conclude a good efficacy and safety

  19. Adaptive and Resilient Soft Tensegrity Robots.

    PubMed

    Rieffel, John; Mouret, Jean-Baptiste

    2018-04-17

    Living organisms intertwine soft (e.g., muscle) and hard (e.g., bones) materials, giving them an intrinsic flexibility and resiliency often lacking in conventional rigid robots. The emerging field of soft robotics seeks to harness these same properties to create resilient machines. The nature of soft materials, however, presents considerable challenges to aspects of design, construction, and control-and up until now, the vast majority of gaits for soft robots have been hand-designed through empirical trial-and-error. This article describes an easy-to-assemble tensegrity-based soft robot capable of highly dynamic locomotive gaits and demonstrating structural and behavioral resilience in the face of physical damage. Enabling this is the use of a machine learning algorithm able to discover effective gaits with a minimal number of physical trials. These results lend further credence to soft-robotic approaches that seek to harness the interaction of complex material dynamics to generate a wealth of dynamical behaviors.

  20. Alveolar soft part sarcoma causing perianal abscess.

    PubMed

    Sullivan, Niall; McCulloch, Tom; Leverton, David

    2011-07-01

    A 34-year-old woman presented with a perianal abscess that communicated with the vagina. There was a background of a one-year history of a conservatively treated, traumatic, paravaginal haematoma. Histology of the fistula tract showed alveolar soft part sarcoma and subsequent imaging identified a large soft tissue mass in the pelvis with lung metastases. Alveolar soft part sarcoma is a rare soft tissue sarcoma of unknown cellular origin affecting predominantly young women, often in deep soft tissues and lower extremities.

  1. Soft tissue and intra-articular injection of bupivacaine, epinephrine, and morphine has a beneficial effect after total knee arthroplasty.

    PubMed

    Lombardi, Adolph V; Berend, Keith R; Mallory, Thomas H; Dodds, Kathleen L; Adams, Joanne B

    2004-11-01

    The purpose of this study was to determine if an intraoperative intraarticular and soft-tissue injection of local anaesthetic, epinephrine, and morphine has a beneficial effect for total knee arthroplasty. A control group of 138 patients (181 knees) received no intraoperative injection. The study group of 171 patients (197 knees) received intraoperative injection of 0.25% bupivacaine with epinephrine and morphine with 2/3 injected into the soft tissues and 1/3 injected into the joint. Patients having bilateral simultaneous procedures received a divided dose. The pain treatment protocol otherwise was identical. Pain, sedation, rescue narcotic usage, narcotic reversal and blood loss were examined. Pain levels during the immediate postoperative period, blood loss, and bleeding indices were reduced with injection. Considerably more control patients required rescue doses of narcotics. Preemptive analgesia with soft tissue and intra-articular injection of long-acting local anesthetic with epinephrine and morphine provides better pain control in the immediate postoperative period, decreases blood loss, and decreases the need for rescue narcotics and reversal agents. This simple, inexpensive method provides an effective adjunct to a multimodal approach in improving the postoperative course of primary total knee arthroplasty.

  2. Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.

    PubMed

    Hast, Michael W; Piazza, Stephen J

    2013-02-01

    Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.

  3. Not-so-Soft Skills

    ERIC Educational Resources Information Center

    Curran, Mary

    2010-01-01

    Much recent discussion about the skills needed to secure Britain's economic recovery has focused on skills for employability. However, too often, these fundamental skills are understood in narrow functional or vocational terms. So-called "soft skills", what Penelope Tobin, in her 2008 paper "Soft Skills: the hard facts", terms "traits and…

  4. Joint hypermobility in children with idiopathic scoliosis: SOSORT award 2011 winner

    PubMed Central

    2011-01-01

    Background Generalized joint hypermobility (JHM) refers to increased joint mobility with simultaneous absence of any other systemic disease. JHM involves proprioception impairment, increased frequency of pain within joints and tendency to injure soft tissues while performing physical activities. Children with idiopathic scoliosis (IS) often undergo intensive physiotherapy requiring good physical capacities. Further, some physiotherapy methods apply techniques that increase joint mobility and thus may be contraindicated. The aim of this paper was to assess JHM prevalence in children with idiopathic scoliosis and to analyze the relationship between JHM prevalence and the clinical and radiological parameters of scoliosis. The methods of assessment of generalized joint hypermobility were also described. Materials and methods This case-control study included 70 subjects with IS, aged 9-18 years (mean 13.2 ± 2.2), Cobb angle range 10°-53° (mean 24.3 ± 11.7), 34 presenting single curve thoracic scoliosis and 36 double curve thoracic and lumbar scoliosis. The control group included 58 children and adolescents aged 9-18 years (mean 12.6 ± 2.1) selected at random. The presence of JHM was determined using Beighton scale complemented with the questionnaire by Hakim and Grahame. The relationship between JHM and the following variables was evaluated: curve severity, axial rotation of the apical vertebra, number of curvatures (single versus double), number of vertebrae within the curvature (long versus short curves), treatment type (physiotherapy versus bracing) and age. Statistical analysis was performed with Statistica 8.1 (StatSoft, USA). The Kolmogorov-Smirnov test, U Mann-Whitney test, Chi2 test, Pearson and Spermann correlation rank were conducted. The value p = 0.05 was adopted as the level of significance. Results JHM was diagnosed in more than half of the subjects with idiopathic scoliosis (51.4%), whilst in the control group it was diagnosed in only 19% of cases (p

  5. Changing patterns of soft drug use prior to and during pregnancy: a prospective study.

    PubMed

    Fried, P A; Watkinson, B; Grant, A; Knights, R M

    1980-11-01

    Two hundred and seventeen women were interviewed during various stages of pregnancy to determine the extent and changing patterns of alcohol, nicotine and marihuana use in the year before pregnancy and during each trimester of pregnancy. Nutritional intake did not vary among women in the various drug using categories. Before pregnancy, 18% of the women were heavy social drinkers. During the first trimester this proportion was reduced by two-thirds and, in contrast to the other levels of social drinking, continued to decline during the last two trimesters. Age, income, education and smoking were all positively associated with heavy social drinking. Heavy cigarette smoking was reported by 13% of the women before pregnancy and by 8% during each of the trimesters. Education and income were negatively associated with heavy smoking. Three per cent of the women reported smoking more than five joints of marihuana per week before pregnancy and most continued to smoke marihuana heavily during pregnancy. The heavy marihuana users had a lower family income and less formal education than the overall sample. Marihuana use in general was associated with cigarette smoking and was not reported by women over 32 years of age. Except for heavy social drinking, soft drug habits at all levels of usage remained essentially unchanged after the first trimester. The likelihood of any one particular soft drug being reduced once pregnancy was established did not vary as a function of the concomitant use of other soft drug(s).

  6. The effect of soft tissue release of the hips on walking in myelomeningocele.

    PubMed

    Correll, J; Gabler, C

    2000-06-01

    Walking and standing capacity in myelomeningocele is highly dependent on the level of the neurological lesion. Deformities, mainly flexion deformities, of the hip can severely interfere with mobility. In a retrospective study, undertaken in our hospital, we evaluated the role of soft tissue release of the hip in patients with hip flexion contractures. A special surgical technique was performed in 55 hips. The results show a good effect on verticalization, even if the hip joints cannot be extended actively. A subluxated or dislocated hip did not influence the final outcome. During the mean follow-up of approximately 4 years, only a slight recurrence of the former deformity was observed. Most of the patients obtained great advantage from the operation.

  7. 3D printing of soft robotic systems

    NASA Astrophysics Data System (ADS)

    Wallin, T. J.; Pikul, J.; Shepherd, R. F.

    2018-06-01

    Soft robots are capable of mimicking the complex motion of animals. Soft robotic systems are defined by their compliance, which allows for continuous and often responsive localized deformation. These features make soft robots especially interesting for integration with human tissues, for example, the implementation of biomedical devices, and for robotic performance in harsh or uncertain environments, for example, exploration in confined spaces or locomotion on uneven terrain. Advances in soft materials and additive manufacturing technologies have enabled the design of soft robots with sophisticated capabilities, such as jumping, complex 3D movements, gripping and releasing. In this Review, we examine the essential soft material properties for different elements of soft robots, highlighting the most relevant polymer systems. Advantages and limitations of different additive manufacturing processes, including 3D printing, fused deposition modelling, direct ink writing, selective laser sintering, inkjet printing and stereolithography, are discussed, and the different techniques are investigated for their application in soft robotic fabrication. Finally, we explore integrated robotic systems and give an outlook for the future of the field and remaining challenges.

  8. Flexocoupling impact on the generalized susceptibility and soft phonon modes in the ordered phase of ferroics

    DOE PAGES

    Morozovska, Anna N.; Vysochanskii, Yulian M.; Varenyk, Oleksandr V.; ...

    2015-09-29

    The impact of the flexoelectric effect on the generalized susceptibility and soft phonon dispersion is not well known in the long-range-ordered phases of ferroics. Within the Landau-Ginzburg-Devonshire approach we obtained analytical expressions for the generalized susceptibility and phonon dispersion relations in the ferroelectric phase. The joint action of the static and dynamic flexoelectric effects induces nondiagonal components of the generalized susceptibility, whose amplitude is proportional to the convolution of the spontaneous polarization with the flexocoupling constants. The flexocoupling essentially broadens the k spectrum of the generalized susceptibility and leads to an additional “pushing away” of the optical and acoustic softmore » mode phonon branches. The degeneracy of the transverse optical and acoustic modes disappears in the ferroelectric phase in comparison with the paraelectric phase due to the joint action of flexoelectric coupling and ferroelectric nonlinearity. Lastly, the results obtained might be mainly important for theoretical analyses of a broad spectrum of experimental data, including neutron and Brillouin scattering.« less

  9. Flow-Through Free Fibula Osteocutaneous Flap in Reconstruction of Tibial Bone, Soft Tissue, and Main Artery Segmental Defects.

    PubMed

    Li, Zonghuan; Yu, Aixi; Qi, Baiwen; Pan, Zhenyu; Ding, Junhui

    2017-08-01

    The aim of this report was to present the use of flow-through free fibula osteocutaneous flap for the repair of complex tibial bone, soft tissue, and main artery segmental defects. Five patients with bone, soft tissue, and segmental anterior tibial artery defects were included. The lengths of injured tibial bones ranged from 4 to 7 cm. The sizes of impaired soft tissues were between 9 × 4 and 15 × 6 cm. The lengths of defect of anterior tibial artery segments ranged from 6 to 10 cm. Two patients had distal limb perfusion problems. Flow-through free fibula osteocutaneous flap was performed for all 5 patients. Patients were followed for 12 to 18 months. All wounds healed after 1-stage operation, and all flow-through flaps survived. The distal perfusion after vascular repair was normal in all patients. Superficial necrosis of flap edge was noted in 1 case. After the local debridement and partial thickness skin graft, the flap healed uneventfully, and the surgical operation did not increase injury to the donor site. Satisfactory bone union was achieved in all patients in 2 to 4 months postoperation. Enlargement of fibula graft was observed during follow-up from 12 to 18 months. The functions of adjacent joints were recovered, and all patients were able to walk normally. Flow-through free fibula osteocutaneous flap was shown to be an effective and efficient technique for repairing composite tibial bone, soft tissue, and main artery segmental defects. This 1-stage operation should be useful in clinical practice for the treatment of complex bone, soft tissue, and vessel defects.

  10. Temporomandibular joint injury potential imposed by the low-velocity extension-flexion maneuver.

    PubMed

    Howard, R P; Hatsell, C P; Guzman, H M

    1995-03-01

    It has been proposed that significant temporomandibular joint injury can occur as a result of rapid extension-flexion motion of the neck (whip-lash). This motion, which is experienced by passengers in vehicles that undergo rear-end collisions, has been described as causing rapid protrusion and opening of the mandible. It has been speculated that this relative motion between the mandible and the cranium produces forces at the temporomandibular joint (TMJ) that injure the articular elements. The objective of this study was to measure these forces by an experimental method. Accelerometer sensor and high-speed cinematographic data were obtained from the kinematic responses of live human test subjects positioned as occupants in motor vehicles that underwent staged low-velocity rear-end collisions. Linear and moment forces generated at the TMJs were obtained from the resultant acceleration pulse at the craniomandibular complex, estimation of the mass properties of the mandible and its appended soft tissues, and the application of Newton's Second Law of motion. The maximum linear forces generated at the TMJ in a rear-end collision resulting in a velocity change of the test subject of 8 km/h (5 mph) were in the 7 to 10 N (1.6 to 2.2 lb) range. Moment forces at the joint peaked briefly at 0.55 N.m (4.81 lb-in). These force magnitudes generated at the TMJ constitute a minor fraction of the forces experienced at the joint during normal physiologic function. It is a conclusion of this study that injuries to the TMJ attributed to low-velocity "whiplash" cannot be accounted for by the joint forces produced by this maneuver.

  11. Medial joint line bone bruising at MRI complicating acute ankle inversion injury: what is its clinical significance?

    PubMed

    Chan, V O; Moran, D E; Shine, S; Eustace, S J

    2013-10-01

    To assess the incidence and clinical significance of medial joint line bone bruising following acute ankle inversion injury. Forty-five patients who underwent ankle magnetic resonance imaging (MRI) within 2 weeks of acute ankle inversion injury were included in this prospective study. Integrity of the lateral collateral ligament complex, presence of medial joint line bone bruising, tibio-talar joint effusion, and soft-tissue swelling were documented. Clinical follow-up at 6 months was carried out to determine the impact of injury on length of time out of work, delay in return to normal walking, delay in return to sports activity, and persistence of medial joint line pain. Thirty-seven patients had tears of the anterior talofibular ligament (ATFL). Twenty-six patients had medial joint line bone bruising with altered marrow signal at the medial aspect of the talus and congruent surface of the medial malleolus. A complete ATFL tear was seen in 92% of the patients with medial joint line bone bruising (p = 0.05). Patients with an ATFL tear and medial joint line bone bruising had a longer delay in return to normal walking (p = 0.0002), longer delay in return to sports activity (p = 0.0001), and persistent medial joint line pain (p = 0.0003). There was no statistically significant difference in outcome for the eight patients without ATFL tears. Medial joint line bone bruising following an acute ankle inversion injury was significantly associated with a complete ATFL tear, longer delay in the return to normal walking and sports activity, as well as persistent medial joint line pain. Its presence should prompt detailed assessment of the lateral collateral ligament complex, particularly the ATFL. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. Soft Robotics: from scientific challenges to technological applications

    NASA Astrophysics Data System (ADS)

    Laschi, C.

    2016-05-01

    Soft robotics is a recent and rapidly growing field of research, which aims at unveiling the principles for building robots that include soft materials and compliance in the interaction with the environment, so as to exploit so-called embodied intelligence and negotiate natural environment more effectively. Using soft materials for building robots poses new technological challenges: the technologies for actuating soft materials, for embedding sensors into soft robot parts, for controlling soft robots are among the main ones. This is stimulating research in many disciplines and many countries, such that a wide community is gathering around initiatives like the IEEE TAS TC on Soft Robotics and the RoboSoft CA - A Coordination Action for Soft Robotics, funded by the European Commission. Though still in its early stages of development, soft robotics is finding its way in a variety of applications, where safe contact is a main issue, in the biomedical field, as well as in exploration tasks and in the manufacturing industry. And though the development of the enabling technologies is still a priority, a fruitful loop is growing between basic research and application-oriented research in soft robotics.

  13. Windchill-201 - Custom Soft-Type Construction

    NASA Technical Reports Server (NTRS)

    Jones, Corey; LaPha, Steven

    2013-01-01

    This presentation will explain Windchill soft-types-what they are, how they work, and how to construct custom ones, configured specifically for your system. The process and particulars of creating and implementing a WTDocument soft-type will be discussed, and the interaction between soft-types and Windchill objects will be shown.

  14. In vivo anteroposterior translation after meniscal-bearing total knee arthroplasty: effects of soft tissue conditions and flexion angle.

    PubMed

    Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Sakurai, Tetsuya; Toyabe, Shin-Ichi

    2014-08-01

    Anteroposterior (AP) joint translation is an important indicator of good clinical outcome following total knee arthroplasty (TKA). This study evaluated the in vivo relationship between changes in the degree of voluntary soft tissue tension and flexion angle versus simultaneous AP translation after TKA. A posterior cruciate ligament (PCL)-retaining meniscal-bearing design was investigated in 20 knees of 20 patients. AP translation was measured at 30° and 75° flexion with the KT-2000 arthrometer while patients were anesthetized and non-anesthetized. The mean translations at 30° and 75° were 10.5 and 10.4 mm, respectively, in non-anesthetized patients and 13.8 and 12.7 mm, respectively, in patients under anesthesia. AP translation showed a significant positive correlation with soft tissue tension (p < 0.001), but not with flexion angle (p = 0.366). No interaction was observed between soft tissue tension and the flexion angle in terms of AP translation (p = 0.431). Surgeons should recognize that AP translation is greater in anesthetized patients than in non-anesthetized patients, regardless of the flexion angle, with no significant correlation between flexion angle and translation, regardless of the level of consciousness. Because conformity between the tibial insert and femoral component decreases with flexion, whereas the opposing effects of supporting structures, such as muscles, ligaments, and capsules, increases, proper soft tissue tension, particularly retention of a functional PCL, could have an important role in determining AP translation in the current prosthesis design.

  15. [Application of radiofrequency vaporization in arthroscopic treatment of patellofemoral joint disorders].

    PubMed

    Xuan, Tao; Xu, Bin; Xu, Honggang; Wang, Hao

    2009-01-01

    To explore the treatment of patellofemoral joint disorders with radiofrequency vaporization under arthroscopy. From June 2004 to June 2007, 86 cases of patellofemoral joint disorder (98 knees) were treated by lateral retinacular release or medial retinacular tighten added, and combined with bipolar radiofrequency chondroplasty under arthroscopy. There were 30 males (34 knees) and 56 females (64 knees), aging 15-68 years (mean 40 years). The locations were left in 42 cases, right in 32 cases, both sides in 12 cases. The disease course was 3 months to 6 years (mean 30.5 months). In 98 knees, there were 28 knees of static patellar tilt, 10 knees of static patellar subluxation, 45 knees of dynamic patellar tilt and 15 knees of dynamic patellar subluxation. The Lysholm knee score preoperatively was 57.72 +/- 8.86. The patellofemoral cartilage abnormality were classified according to the Outerbridge grade (18 knees of grade I, 36 knees of grade II, 32 knees of grade III and 12 knees of grade IV). The incisions healed by first intention without complications such as infection or hemarthrosis. Seventy-five cases (82 knees) were followed up 8-37 months (mean 20.6 months). One month after operation, the patellofemoral joint pain was relieved remarkably, the knee joint activity was good and the radiological outcomes was also satisfactory. Six months after operation, the Lysholm knee score was improved significantly in patients of grades I, II and III (P < 0.05), while there was no significant change in patients of grade IV (P > 0.05). The postoperative score was 69.95 +/- 5.42 (P < 0.05). Radiofrequency vaporization chondroplasty and soft tissue balance under arthroscopy are advantageous in terms of easy operation, less injury, slight reaction and have good effect on patellofemoral joint disorders.

  16. Distributed Wind Soft Costs: A Beginning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jimenez, Tony; Forsyth,Trudy; Preus, Robert

    2016-06-14

    Tony Jimenez presented this overview of distributed wind soft costs at the 2016 Small Wind Conference in Stevens Point, Wisconsin, on June 14, 2016. Soft costs are any non-hardware project costs, such as costs related to permitting fees, installer/developer profit, taxes, transaction costs, permitting, installation, indirect corporate costs, installation labor, and supply chain costs. This presentation provides an overview of soft costs, a distributed wind project taxonomy (of which soft costs are a subset), an alpha data set project demographics, data summary, and future work in this area.

  17. Controversies In The Surgical Management Of Shoulder Instability: Associated Soft Tissue Procedures

    PubMed Central

    Moros Marco, Santos; Ávila Lafuente, José Luis; Ruiz Ibán, Miguel Angel; Diaz Heredia, Jorge

    2017-01-01

    Background: The glenohumeral joint is a ball-and-socket joint that is inherently unstable and thus, susceptible to dislocation. The traditional and most common anatomic finding is the Bankart lesion (anterior-inferior capsule labral complex avulsion), but there is a wide variety of anatomic alterations that can cause shoulder instability or may be present as a concomitant injury or in combination, including bone loss (glenoid or humeral head), complex capsule-labral tears, rotator cuff tears, Kim´s lesions (injuries to the posterior-inferior labrum) and rotator interval pathology. Methods: A review of articles related to shoulder anatomy and soft tissue procedures that are performed during shoulder instability arthroscopic management was conducted by querying the Pubmed database and conclusions and controversies regarding this injury were exposed. Results: Due to the complex anatomy of the shoulder and the large range of movement of this joint, a wide variety of anatomic injuries and conditions can lead to shoulder instability, specially present in young population. Recognizing and treating all of them including Bankart repair, capsule-labral plicatures, SLAP repair, circumferential approach to pan-labral lesions, rotator interval closure, rotator cuff injuries and HAGL lesion repair is crucial to achieve the goal of a stable, full range of movement and not painful joint. Conclusion: Physicians must be familiarized with all the lesions involved in shoulder instability, and should be able to recognize and subsequently treat them to achieve the goal of a stable non-painful shoulder. Unrecognized or not treated lesions may result in recurrence of instability episodes and pain while overuse of some of the techniques previously described can lead to stiffness, thus the importance of an accurate diagnosis and treatment when facing a shoulder instability. PMID:28979603

  18. On the symmetry foundation of double soft theorems

    NASA Astrophysics Data System (ADS)

    Li, Zhi-Zhong; Lin, Hung-Hwa; Zhang, Shun-Qing

    2017-12-01

    Double-soft theorems, like its single-soft counterparts, arises from the underlying symmetry principles that constrain the interactions of massless particles. While single soft theorems can be derived in a non-perturbative fashion by employing current algebras, recent attempts of extending such an approach to known double soft theorems has been met with difficulties. In this work, we have traced the difficulty to two inequivalent expansion schemes, depending on whether the soft limit is taken asymmetrically or symmetrically, which we denote as type A and B respectively. The soft-behaviour for type A scheme can simply be derived from single soft theorems, and are thus non-perturbatively protected. For type B, the information of the four-point vertex is required to determine the corresponding soft theorems, and thus are in general not protected. This argument can be readily extended to general multi-soft theorems. We also ask whether unitarity can be emergent from locality together with the two kinds of soft theorems, which has not been fully investigated before.

  19. Safety profile of sural nerve in posterolateral approach to the ankle joint: MRI study.

    PubMed

    Ellapparadja, Pregash; Husami, Yaya; McLeod, Ian

    2014-05-01

    The posterolateral approach to ankle joint is well suited for ORIF of posterior malleolar fractures. There are no major neurovascular structures endangering this approach other than the sural nerve. The sural nerve is often used as an autologous peripheral nerve graft and provides sensation to the lateral aspect of the foot. The aim of this paper is to measure the precise distance of the sural nerve from surrounding soft tissue structures so as to enable safe placement of skin incision in posterolateral approach. This is a retrospective image review study involving 64 MRI scans. All measurements were made from Axial T1 slices. The key findings of the paper is the safety window for the sural nerve from the lateral border of tendoachilles (TA) is 7 mm, 1.3 cm and 2 cm at 3 cm above ankle joint, at the ankle joint and at the distal tip of fibula respectively. Our study demonstrates the close relationship of the nerve in relation to TA and fibula in terms of exact measurements. The safety margins established in this study should enable the surgeon in preventing endangerment of the sural nerve encountered in this approach.

  20. Management of chronic ankle pain using joint mobilization and ASTYM® treatment: a case report.

    PubMed

    Slaven, Emily J; Mathers, Jessie

    2011-05-01

    Treatment of ankle sprains predominately focuses on the acute management of this condition; less emphasis is placed on the treatment of ankle sprains in the chronic phase of recovery. Manual therapy, in the form of joint mobilization and manipulation, has been shown to be effective in the management of this condition, but the combination of joint mobilization and manipulation in tandem with ASTYM® treatment has not been explored. The purpose of this case report is to chronicle the management of a patient with chronic ankle pain who was treated with manual therapy including manipulation and ASTYM treatment. As a result of a fall down stairs 6 months previously, the patient sustained a severe ankle sprain. The soft tissue damage was accompanied by bony disruptions which warranted the patient spending 3 weeks in a walking boot. At the initial evaluation, the patient reported difficulty with descending stairs reciprocally and not being able to run more than 4 minutes on the treadmill before the pain escalated to the level that she had to stop running. After five sessions of therapy consisting of joint mobilization, manipulation and ASTYM, the patient was able to descend stairs and run 40 minutes without pain.

  1. Energy efficiency of mobile soft robots.

    PubMed

    Shui, Langquan; Zhu, Liangliang; Yang, Zhe; Liu, Yilun; Chen, Xi

    2017-11-15

    The performance of mobile soft robots is usually characterized by their locomotion/velocity efficiency, whereas the energy efficiency is a more intrinsic and fundamental criterion for the performance evaluation of independent or integrated soft robots. In this work, a general framework is established to evaluate the energy efficiency of mobile soft robots by considering the efficiency of the energy source, actuator and locomotion, and some insights for improving the efficiency of soft robotic systems are presented. Proposed as the ratio of the desired locomotion kinetic energy to the input mechanical energy, the energy efficiency of locomotion is found to play a critical role in determining the overall energy efficiency of soft robots. Four key factors related to the locomotion energy efficiency are identified, that is, the locomotion modes, material properties, geometric sizes, and actuation states. It is found that the energy efficiency of most mobile soft robots reported in the literature is surprisingly low (mostly below 0.1%), due to the inefficient mechanical energy that essentially does not contribute to the desired locomotion. A comparison of the locomotion energy efficiency for several representative locomotion modes in the literature is presented, showing a descending ranking as: jumping ≫ fish-like swimming > snake-like slithering > rolling > rising/turning over > inchworm-like inching > quadruped gait > earthworm-like squirming. Besides, considering the same locomotion mode, soft robots with lower stiffness, higher density and larger size tend to have higher locomotion energy efficiency. Moreover, a periodic pulse actuation instead of a continuous actuation mode may significantly reduce the input mechanical energy, thus improving the locomotion energy efficiency, especially when the pulse actuation matches the resonant states of the soft robots. The results presented herein indicate a large and necessary space for improving the locomotion energy

  2. Wanted: Soft Skills for Today's Jobs

    ERIC Educational Resources Information Center

    Hirsch, Barton J.

    2017-01-01

    Educating high school students for both college and career is difficult. Teaching trade skills seems alien to the academic culture. But new research indicates that soft skills are quite important to judgments of employability and that youth learn many soft skills in traditional academic subjects (e.g., literature). A focus on soft skills allows…

  3. Multi-User Space Link Extension (SLE) System

    NASA Technical Reports Server (NTRS)

    Perkins, Toby

    2013-01-01

    The Multi-User Space (MUS) Link Extension system, a software and data system, provides Space Link Extension (SLE) users with three space data transfer services in timely, complete, and offline modes as applicable according to standards defined by the Consultative Committee for Space Data Systems (CCSDS). MUS radically reduces the schedule, cost, and risk of implementing a new SLE user system, minimizes operating costs with a lights-out approach to SLE, and is designed to require no sustaining engineering expense during its lifetime unless changes in the CCSDS SLE standards, combined with new provider implementations, force changes. No software modification to MUS needs to be made to support a new mission. Any systems engineer with Linux experience can begin testing SLE user service instances with MUS starting from a personal computer (PC) within five days. For flight operators, MUS provides a familiar-looking Web page for entering SLE configuration data received from SLE. Operators can also use the Web page to back up a space mission's entire set of up to approximately 500 SLE service instances in less than five seconds, or to restore or transfer from another system the same amount of data from a MUS backup file in about the same amount of time. Missions operate each MUS SLE service instance independently by sending it MUS directives, which are legible, plain ASCII strings. MUS directives are usually (but not necessarily) sent through a TCP-IP (Transmission Control Protocol Internet Protocol) socket from a MOC (Mission Operations Center) or POCC (Payload Operations Control Center) system, under scripted control, during "lights-out" spacecraft operation. MUS permits the flight operations team to configure independently each of its data interfaces; not only commands and telemetry, but also MUS status messages to the MOC. Interfaces can use single- or multiple-client TCP/IP server sockets, TCP/IP client sockets, temporary disk files, the system log, or standard in

  4. [Ultrasound in complex of radiological studies in diagnosis of ankle joint medial aspect pathologies].

    PubMed

    Gurgenidze, T; Mizandari, M

    2011-10-01

    The aim of the research is to study sonosemiotics of ankle joint pathology by means of ultrasound in order to optimize the diagnostic process and improve the treatment. 130 patients (age ranges from 5 to 70 years) underwent the radiological study of ankle joint medial aspect. Pathology types: degenerative-dystrophic diseases - 39 (30%), inflammatory pathology - 21 (16.2%), traumatic injuries - 20 (15.2%), vascular pathologies - 26 (20%), neurogenic problems -7 (5.4%), soft tissue neoplasms - 5 (3.8%), congenital anomalies - 7 (5.4%) and vertebral pathology - 5 (4.0%). The diagnostic studies include: a) Ultrasound, performed on digital ultrasound system using high frequency (7.5-12.0 MHz) linear probe with Doppler capability (all patients); b) X-Ray filming in antero-posterior and lateral projections (6 patients- 4.5%); c) MRI - T1 and T2 weighted images in saggital and transverse planes 10 patients (10.0%) and d) CT - 2 patients (1.5%); To 2 (1.5%) patient biopsy has been performed. This study showed that ultrasound was successful in ankle joint medial aspect pathology diagnosis in 108 cases (84.0%); It was ineffective in osseous pathology definition. In final diagnosis of impingment syndrom MRI was required in 4 (3.6%) cases. It is concluded that ultrasound should be used as a Gold Standard in diagnosis of localized pain and swelling in the ankle joint.

  5. Soft-Input Soft-Output Modules for the Construction and Distributed Iterative Decoding of Code Networks

    NASA Technical Reports Server (NTRS)

    Benedetto, S.; Divsalar, D.; Montorsi, G.; Pollara, F.

    1998-01-01

    Soft-input soft-output building blocks (modules) are presented to construct and iteratively decode in a distributed fashion code networks, a new concept that includes, and generalizes, various forms of concatenated coding schemes.

  6. In vitro method for assessing the biomechanics of the patellofemoral joint following total knee arthroplasty.

    PubMed

    Coles, L G; Gheduzzi, S; Miles, A W

    2014-12-01

    The patellofemoral joint is a common site of pain and failure following total knee arthroplasty. A contributory factor may be adverse patellofemoral biomechanics. Cadaveric investigations are commonly used to assess the biomechanics of the joint, but are associated with high inter-specimen variability and often cannot be carried out at physiological levels of loading. This study aimed to evaluate the suitability of a novel knee simulator for investigating patellofemoral joint biomechanics. This simulator specifically facilitated the extended assessment of patellofemoral joint biomechanics under physiological levels of loading. The simulator allowed the knee to move in 6 degrees of freedom under quadriceps actuation and included a simulation of the action of the hamstrings. Prostheses were implanted on synthetic bones and key soft tissues were modelled with a synthetic analogue. In order to evaluate the physiological relevance and repeatability of the simulator, measurements were made of the quadriceps force and the force, contact area and pressure within the patellofemoral joint using load cells, pressure-sensitive film, and a flexible pressure sensor. The results were in agreement with those previously reported in the literature, confirming that the simulator is able to provide a realistic physiological loading situation. Under physiological loading, average standard deviations of force and area measurements were substantially lower and comparable to those reported in previous cadaveric studies, respectively. The simulator replicates the physiological environment and has been demonstrated to allow the initial investigation of factors affecting patellofemoral biomechanics following total knee arthroplasty. © IMechE 2014.

  7. Astym® Therapy for the Management of Recalcitrant Knee Joint Stiffness after Total Knee Arthroplasty.

    PubMed

    Bhave, Anil; Corcoran, James; Cherian, Jeffery J; Mont, Michael A

    2016-01-01

    Knee stiffness is a common complication after total knee arthroplasty (TKA). Despite studies published on the surgical management of reduced range of motion (ROM) after TKA, there is limited evidence on the nonoperative management of joint and soft tissue imbalances possibly contributing to reduced knee ROM. This report assesses changes in ROM, pain, function, and patellar tendon length after Astym® joint mobilization use. A 38-year-old male professional skier had a right TKA 3 months before presentation with 2 subsequent manipulations under anesthesia secondary to persistent knee stiffness. He had patellar baja on radiograph, a reduced arc of ROM, reduced patellar mobility and muscular extensibility, and pain to palpation along the patellar tendon. He had 12 visits of physical therapy with the use of Astym®, patellar mobilization, and tibio-femoral mobilizations with movement. The patient also used a customized knee device at home for prolonged knee extension stretching. The patient was treated for 12 visits, along with home use of customized bracing for knee extension. Significant improvements were seen in pain, function, and ROM. He returned to work full-time, ambulated prolonged distances, and negotiated stairs pain-free. He also demonstrated resolution of patellar baja radiographically. Conservative management of recalcitrant knee joint stiffness after primary TKA can be effective in restoring knee mobility and reducing pain and activity limitation. A multimodal approach using Astym® treatment, customized knee bracing, and targeted joint mobilization can be effective in resolving knee joint stiffness.

  8. PRESERVATION OF SOFT FRUIT BY RADIOPASTEURISATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vidal, P.

    Aspects of the problem of soft fruit preservation by radiation are discussed. Particular attention is given to fresh soft fruit treatment techniques, packaging, types of installations, and economic considerations. It is pointed out that the clearest and most consistent results were obtained with soft, thin-skinned fruit such as strawberries, blackberries, and raspberries. (H.M.G.)

  9. Wavelength calibration of x-ray imaging crystal spectrometer on Joint Texas Experimental Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, W.; Chen, Z. Y., E-mail: zychen@hust.edu.cn; Jin, W.

    2014-11-15

    The wavelength calibration of x-ray imaging crystal spectrometer is a key issue for the measurements of plasma rotation. For the lack of available standard radiation source near 3.95 Å and there is no other diagnostics to measure the core rotation for inter-calibration, an indirect method by using tokamak plasma itself has been applied on joint Texas experimental tokamak. It is found that the core toroidal rotation velocity is not zero during locked mode phase. This is consistent with the observation of small oscillations on soft x-ray signals and electron cyclotron emission during locked-mode phase.

  10. Further links between the maximum hardness principle and the hard/soft acid/base principle: insights from hard/soft exchange reactions.

    PubMed

    Chattaraj, Pratim K; Ayers, Paul W; Melin, Junia

    2007-08-07

    Ayers, Parr, and Pearson recently showed that insight into the hard/soft acid/base (HSAB) principle could be obtained by analyzing the energy of reactions in hard/soft exchange reactions, i.e., reactions in which a soft acid replaces a hard acid or a soft base replaces a hard base [J. Chem. Phys., 2006, 124, 194107]. We show, in accord with the maximum hardness principle, that the hardness increases for favorable hard/soft exchange reactions and decreases when the HSAB principle indicates that hard/soft exchange reactions are unfavorable. This extends the previous work of the authors, which treated only the "double hard/soft exchange" reaction [P. K. Chattaraj and P. W. Ayers, J. Chem. Phys., 2005, 123, 086101]. We also discuss two different approaches to computing the hardness of molecules from the hardness of the composing fragments, and explain how the results differ. In the present context, it seems that the arithmetic mean of fragment softnesses is the preferable definition.

  11. Soft Lithography

    NASA Astrophysics Data System (ADS)

    Xia, Younan; Whitesides, George M.

    1998-08-01

    Soft lithography represents a non-photolithographic strategy based on selfassembly and replica molding for carrying out micro- and nanofabrication. It provides a convenient, effective, and low-cost method for the formation and manufacturing of micro- and nanostructures. In soft lithography, an elastomeric stamp with patterned relief structures on its surface is used to generate patterns and structures with feature sizes ranging from 30 nm to 100 mum. Five techniques have been demonstrated: microcontact printing (muCP), replica molding (REM), microtransfer molding (muTM), micromolding in capillaries (MIMIC), and solvent-assisted micromolding (SAMIM). In this chapter we discuss the procedures for these techniques and their applications in micro- and nanofabrication, surface chemistry, materials science, optics, MEMS, and microelectronics.

  12. Local deformation for soft tissue simulation

    PubMed Central

    Omar, Nadzeri; Zhong, Yongmin; Smith, Julian; Gu, Chengfan

    2016-01-01

    ABSTRACT This paper presents a new methodology to localize the deformation range to improve the computational efficiency for soft tissue simulation. This methodology identifies the local deformation range from the stress distribution in soft tissues due to an external force. A stress estimation method is used based on elastic theory to estimate the stress in soft tissues according to a depth from the contact surface. The proposed methodology can be used with both mass-spring and finite element modeling approaches for soft tissue deformation. Experimental results show that the proposed methodology can improve the computational efficiency while maintaining the modeling realism. PMID:27286482

  13. Effects of Soft Tissue Surgery on Pelvic and Hip Rotation in Patients with Spastic Diplegia: A Meta-Analysis.

    PubMed

    Jung, Hun Jae; Yoon, Ji Yeon; Oh, Min Kyung; Kim, Young Chang; Kim, Jae Hyun; Eom, Tae Woong; Park, Kun Bo

    2016-06-01

    There are several different opinions regarding the improvements seen on the transverse plane after soft tissue surgery alone in independently ambulant patients with cerebral palsy. We performed a meta-analysis using data from previous studies to identify the effects of soft tissue surgery alone on pelvic and hip rotation in children with spastic diplegia. We conducted a pilot study to evaluate the improvement in pelvic and hip rotation after muscle-tendon lengthening surgery in children with spastic diplegia. We also searched EMBASE and PubMed and selected 2 previous studies using the same test conditions with kinematic data on the pelvis and hip joints. A meta-analysis of the results of these 3 studies, including this pilot study, was then performed. The meta-analysis results showed an external rotation decrease (p = 0.005) in the mean difference of pelvic rotation of -3.61 (95% confidence interval [CI], -6.13 to -1.09) and a mean difference in hip rotation of 6.60 (95% CI, 3.34 to 9.86), indicating a significant increase in the hip external rotation after surgery (p < 0.001). In independently community-ambulant pediatric patients with spastic diplegia, pelvic retraction and hip internal rotation could be improved after soft tissue surgery.

  14. Differences in knee joint kinematics and forces after posterior cruciate retaining and stabilized total knee arthroplasty.

    PubMed

    Wünschel, Markus; Leasure, Jeremi M; Dalheimer, Philipp; Kraft, Nicole; Wülker, Nikolaus; Müller, Otto

    2013-12-01

    Posterior cruciate ligament (PCL) retaining (CR) and -sacrificing (PS) total knee arthroplasties (TKA) are widely-used to treat osteoarthritis of the knee joint. The PS design substitutes the function of the PCL with a cam-spine mechanism which may produce adverse changes to joint kinematics and kinetics. CR- and PS-TKA were performed on 11 human knee specimens. Joint kinematics were measured with a dynamic knee simulator and motion tracking equipment. In-situ loads of the PCL and cam-spine were measured with a robotic force sensor system. Partial weight bearing flexions were simulated and external forces were applied. The PS-TKA rotated significantly less throughout the whole flexion range compared to the CR-TKA. Femoral roll back was greater in the PS-TKA; however, this was not correlated with lower quadriceps forces. Application of external loads produced significantly different in-situ force profiles between the TKA systems. Our data demonstrate that the PS-design significantly alters kinematics of the knee joint. Our data also suggest the cam-spine mechanism may have little influence on high flexion kinematics (such as femoral rollback) with most of the load burden shared by supporting implant and soft-tissue structures. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Soft Decision Analyzer and Method

    NASA Technical Reports Server (NTRS)

    Zucha, Joan P. (Inventor); Schlesinger, Adam M. (Inventor); Lansdowne, Chatwin (Inventor); Steele, Glen F. (Inventor)

    2015-01-01

    A soft decision analyzer system is operable to interconnect soft decision communication equipment and analyze the operation thereof to detect symbol wise alignment between a test data stream and a reference data stream in a variety of operating conditions.

  16. Soft Decision Analyzer and Method

    NASA Technical Reports Server (NTRS)

    Zucha, Joan P. (Inventor); Schlesinger, Adam M. (Inventor); Lansdowne, Chatwin (Inventor); Steele, Glen F. (Inventor)

    2016-01-01

    A soft decision analyzer system is operable to interconnect soft decision communication equipment and analyze the operation thereof to detect symbol wise alignment between a test data stream and a reference data stream in a variety of operating conditions.

  17. A practical solution to reduce soft tissue artifact error at the knee using adaptive kinematic constraints.

    PubMed

    Potvin, Brigitte M; Shourijeh, Mohammad S; Smale, Kenneth B; Benoit, Daniel L

    2017-09-06

    Musculoskeletal modeling and simulations have vast potential in clinical and research fields, but face various challenges in representing the complexities of the human body. Soft tissue artifact from skin-mounted markers may lead to non-physiological representation of joint motions being used as inputs to models in simulations. To address this, we have developed adaptive joint constraints on five of the six degree of freedom of the knee joint based on in vivo tibiofemoral joint motions recorded during walking, hopping and cutting motions from subjects instrumented with intra-cortical pins inserted into their tibia and femur. The constraint boundaries vary as a function of knee flexion angle and were tested on four whole-body models including four to six knee degrees of freedom. A musculoskeletal model developed in OpenSim simulation software was constrained to these in vivo boundaries during level gait and inverse kinematics and dynamics were then resolved. Statistical parametric mapping indicated significant differences (p<0.05) in kinematics between bone pin constrained and unconstrained model conditions, notably in knee translations, while hip and ankle flexion/extension angles were also affected, indicating the error at the knee propagates to surrounding joints. These changes to hip, knee, and ankle kinematics led to measurable changes in hip and knee transverse plane moments, and knee frontal plane moments and forces. Since knee flexion angle can be validly represented using skin mounted markers, our tool uses this reliable measure to guide the five other degrees of freedom at the knee and provide a more valid representation of the kinematics for these degrees of freedom. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Degenerative joint disease: multiple joint involvement in young and mature dogs.

    PubMed

    Olsewski, J M; Lust, G; Rendano, V T; Summers, B A

    1983-07-01

    Radiologic, pathologic, and ancillary methods were used to determine the occurrence of degenerative joint disease involving multiple joints of immature and adult dogs. Animals were selected for the development of hip joint dysplasia and chronic degenerative joint disease. Of disease-prone dogs, 82% (45 of 55 dogs) had radiologic changes, indicative of hip dysplasia, by 1 year of age. At necropsy, more abnormal joints were identified than by radiographic examination. Among 92 dogs between 3 to 11 months of age that had joint abnormalities, 71% had hip joint involvement; 38%, shoulder joint involvement; 22%, stifle joint involvement; and 40% had multiple joint involvement. Polyarthritis was asymptomatic and unexpected. Radiographic examination of older dogs also revealed evidence of degenerative joint disease in many joints. Multiple joint involvement was substantiated at necropsy of young and mature dogs. A similar pattern of polyarticular osteoarthritis was revealed in a survey (computer search) of necropsy reports from medical case records of 100 adult and elderly dogs. Usually, the joint disease was an incidental observation, unrelated to the clinical disease or to the cause of death. The frequent occurrence of degenerative changes in several joints of dogs aged 6 months to 17 years indicated that osteoarthritis may be progressive in these joints and raises the possibility that systemic factors are involved in the disease process.

  19. Design and Fabrication of a Universal Soft Gripper

    NASA Astrophysics Data System (ADS)

    Sabzehzar, Amin

    Inspired from nature, soft robots capable of actively tuning their mechanical rigidity can rapidly transition between a broad range of motor tasks, from lifting heavy loads to dexterous manipulation of delicate objects. Reversible rigidity tuning also enables soft robotic actuators to reroute their internal loading and alter their mode of deformation in response to intrinsic activation. In this study, we demonstrate this principle with a three-fingered pneumatic gripper that contains programmable ligaments that change stiness when activated with electrical current. The ligaments are composed of a conductive thermoplastic elastomer composite that reversibly softens under resistive heating. Depending on which ligaments are activated, the gripper will bend inward to pick up an object, bend laterally to twist it, or bend outward to release it. Each finger consists of three PDMS phalanges that are attached with two Ecoflex joints. Three ligaments (strips of a cPBE-PDMS composite layer) are attached along the finger and are stimulated with electricity individually. When the high pressure air is injected in the hollow middle part of the finger, the finger will be bent in the opposite direction of the stimulated cPBE-PDMS element (softer wall). This enables the gripper's fingers to grab and twist objects with dierent sizes and shapes. All of the gripper motions are generated with a single pneumatic source of pressure and are controlled with an electrical board. The ability to incorporate electrically programmable ligaments in pneumatic or hydraulic actuators has the potential to enhance versatility and reduce dependency on tubing and valves. In this study, an activation/deactivation cycle can be completed within 15 s.

  20. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  1. Collateral ligament strains during knee joint laxity evaluation before and after TKA.

    PubMed

    Delport, Hendrik; Labey, Luc; De Corte, Ronny; Innocenti, Bernardo; Vander Sloten, Jos; Bellemans, Johan

    2013-08-01

    Passive knee stability is provided by the soft tissue envelope. There is consensus among orthopedic surgeons that good outcome in Total Knee Arthroplasty requires equal tension in the medial/lateral compartment of the knee joint, as well as equal tension in the flexion/extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after Posterior-Stabilized Total Knee Arthroplasty. We hypothesized that the Medial/Lateral Collateral Ligament shows minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to reconstruct using a Posterior-Stabilized Total Knee. Six specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. This study enabled a precise measurement of varus-valgus laxity as compared with the clinical assessment. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the Medial Collateral Ligament tends to relax and the Lateral Collateral Ligament remains tight. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend to avoid overstuffing the joint, when using this type of Posterior-Stabilized Total Knee Arthroplasty, in order to obtain varus/valgus laxity close to the native joint. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. 3D printing for soft robotics - a review.

    PubMed

    Gul, Jahan Zeb; Sajid, Memoon; Rehman, Muhammad Muqeet; Siddiqui, Ghayas Uddin; Shah, Imran; Kim, Kyung-Hwan; Lee, Jae-Wook; Choi, Kyung Hyun

    2018-01-01

    Soft robots have received an increasing attention due to their advantages of high flexibility and safety for human operators but the fabrication is a challenge. Recently, 3D printing has been used as a key technology to fabricate soft robots because of high quality and printing multiple materials at the same time. Functional soft materials are particularly well suited for soft robotics due to a wide range of stimulants and sensitive demonstration of large deformations, high motion complexities and varied multi-functionalities. This review comprises a detailed survey of 3D printing in soft robotics. The development of key 3D printing technologies and new materials along with composites for soft robotic applications is investigated. A brief summary of 3D-printed soft devices suitable for medical to industrial applications is also included. The growing research on both 3D printing and soft robotics needs a summary of the major reported studies and the authors believe that this review article serves the purpose.

  3. Spacesuit mobility joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1978-01-01

    Joints for use in interconnecting adjacent segments of an hermetically sealed spacesuit which have low torques, low leakage and a high degree of reliability are described. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics. Linkages which restrain the joint from longitudinal distension and a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli are featured. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  4. Dental plaque pH variation with regular soft drink, diet soft drink and high energy drink: an in vivo study.

    PubMed

    Jawale, Bhushan Arun; Bendgude, Vikas; Mahuli, Amit V; Dave, Bhavana; Kulkarni, Harshal; Mittal, Simpy

    2012-03-01

    A high incidence of dental caries and dental erosion associated with frequent consumption of soft drinks has been reported. The purpose of this study was to evaluate the pH response of dental plaque to a regular, diet and high energy drink. Twenty subjects were recruited for this study. All subjects were between the ages of 20 and 25 and had at least four restored tooth surfaces present. The subjects were asked to refrain from brushing for 48 hours prior to the study. At baseline, plaque pH was measured from four separate locations using harvesting method. Subjects were asked to swish with 15 ml of the respective soft drink for 1 minute. Plaque pH was measured at the four designated tooth sites at 5, 10 and 20 minutes intervals. Subjects then repeated the experiment using the other two soft drinks. pH was minimum for regular soft drink (2.65 ± 0.026) followed by high energy drink (3.39 ± 0.026) and diet soft drink (3.78 ± 0.006). The maximum drop in plaque pH was seen with regular soft drink followed by high energy drink and diet soft drink. Regular soft drink possesses a greater acid challenge potential on enamel than diet and high energy soft drinks. However, in this clinical trial, the pH associated with either soft drink did not reach the critical pH which is expected for enamel demineralization and dissolution.

  5. Nociceptive role of substance-P in the knee joint of a patient with congenital insensitivity to pain.

    PubMed

    Derwin, K A; Glover, R A; Wojtys, E M

    1994-01-01

    This case report describes the immunocytochemical examination of tissue from a 9-year-old black child diagnosed with congenital insensitivity to pain at age 5. A recent fall and resulting patella fracture required surgical treatment. Biopsies of the distal pole and surrounding soft tissue, as well as a sample of his patellofemoral joint fluid, were taken at the time of partial patellectomy and analyzed for substance-P (SP). Morphologic staining of the patella showed a grossly degenerated patellofemoral articular surface. Examination of tissue sections stained either immunocytochemically with diaminobenzidine DAB or by a rhodamine fluorescent labeling technique showed no evidence of SP-positive nerve fibers. Furthermore, only a trace amount of SP (7.29 pg/ml) was detected in a sample of the patient's knee joint synovial fluid. This patient's absence of pain sensation in conjunction with the absence of SP nerve fibers in stained patella sections and identification of only trace levels of SP in his synovial fluid, further implicates this neuropeptide in nociceptive innervation of diarthrodial joints.

  6. Fiber-reinforced scaffolds in soft tissue engineering

    PubMed Central

    Wang, Wei; Fan, Yubo; Wang, Xiumei; Watari, Fumio

    2017-01-01

    Abstract Soft tissue engineering has been developed as a new strategy for repairing damaged or diseased soft tissues and organs to overcome the limitations of current therapies. Since most of soft tissues in the human body are usually supported by collagen fibers to form a three-dimensional microstructure, fiber-reinforced scaffolds have the advantage to mimic the structure, mechanical and biological environment of natural soft tissues, which benefits for their regeneration and remodeling. This article reviews and discusses the latest research advances on design and manufacture of novel fiber-reinforced scaffolds for soft tissue repair and how fiber addition affects their structural characteristics, mechanical strength and biological activities in vitro and in vivo. In general, the concept of fiber-reinforced scaffolds with adjustable microstructures, mechanical properties and degradation rates can provide an effective platform and promising method for developing satisfactory biomechanically functional implantations for soft tissue engineering or regenerative medicine. PMID:28798872

  7. The Viking viewer for connectomics: scalable multi-user annotation and summarization of large volume data sets

    PubMed Central

    ANDERSON, JR; MOHAMMED, S; GRIMM, B; JONES, BW; KOSHEVOY, P; TASDIZEN, T; WHITAKER, R; MARC, RE

    2011-01-01

    Modern microscope automation permits the collection of vast amounts of continuous anatomical imagery in both two and three dimensions. These large data sets present significant challenges for data storage, access, viewing, annotation and analysis. The cost and overhead of collecting and storing the data can be extremely high. Large data sets quickly exceed an individual's capability for timely analysis and present challenges in efficiently applying transforms, if needed. Finally annotated anatomical data sets can represent a significant investment of resources and should be easily accessible to the scientific community. The Viking application was our solution created to view and annotate a 16.5 TB ultrastructural retinal connectome volume and we demonstrate its utility in reconstructing neural networks for a distinctive retinal amacrine cell class. Viking has several key features. (1) It works over the internet using HTTP and supports many concurrent users limited only by hardware. (2) It supports a multi-user, collaborative annotation strategy. (3) It cleanly demarcates viewing and analysis from data collection and hosting. (4) It is capable of applying transformations in real-time. (5) It has an easily extensible user interface, allowing addition of specialized modules without rewriting the viewer. PMID:21118201

  8. Mapping quantitative trait loci for a unique 'super soft' kernel trait in soft white wheat

    USDA-ARS?s Scientific Manuscript database

    Wheat (Triticum sp.) kernel texture is an important factor affecting milling, flour functionality, and end-use quality. Kernel texture is normally characterized as either hard or soft, the two major classes of texture. However, further variation is typically encountered in each class. Soft wheat var...

  9. Dynamic soft variable structure control of singular systems

    NASA Astrophysics Data System (ADS)

    Liu, Yunlong; Zhang, Caihong; Gao, Cunchen

    2012-08-01

    The dynamic soft variable structure control (VSC) of singular systems is discussed in this paper. The definition of soft VSC and the design of its controller modes are given. The stability of singular systems with the dynamic soft VSC is proposed. The dynamic soft variable structure controller is designed, and the concrete algorithm on the dynamic soft VSC is given. The dynamic soft VSC of singular systems which was developed for the purpose of intentionally precluding chattering, achieving high regulation rates and shortening settling times enhanced the dynamic quality of the systems. It is illustrated the feasibility and validity of the proposed strategy by a simulation example, and an outlook on its auspicious further development is presented.

  10. [Soft tissue melanoma: a clinical case].

    PubMed

    Frikh, Rachid; Oumakhir, Siham; Chahdi, Hafsa; Oukabli, Mohammed; Albouzidi, Abderrahmane; Baba, Noureddine; Hjira, Naoufal; Boui, Mohammed

    2017-01-01

    Soft tissue melanoma was first described by Enzinger in 1965 under the name of clear cell sarcoma. In 1983, Chung and Enzinger renamed it soft tissue melanoma due to its immunohistochemical similarities with melanoma. We here report the case of a 22-year old young man with this rare type of melanoma, presenting with molluscoid lesion on his ankle without any clinical sign of malignancy. Histology examination confirmed the diagnosis of soft tissue melanoma.

  11. A Case of Simultaneous Traumatic Dorsal Dislocation of All Five Metatarsophalangeal Joints Treated Successfully With Closed Reduction.

    PubMed

    Bhide, Pushkar P; Anantharaman, Chinnadurai; Mohan, Ganesan; Raju, Karuppanna

    2016-01-01

    Simultaneous dislocation of multiple metatarsophalangeal joints is a rare injury, because of the impediment presented by the anatomy of the lesser metatarsophalangeal joints. To the best of our knowledge, only 1 case of simultaneous dislocation of all 5 metatarsophalangeal joints has been previously reported in peer-reviewed studies. Owing to the same anatomic structures that obstruct relocation, closed reduction has been known to fail in a large proportion of cases. We report a case of simultaneous dorsal dislocation of all 5 metatarsophalangeal joints of the right foot after a motor vehicle accident. The highlight of our case was successful closed reduction after application of the reduction maneuver to all lesser metatarsophalangeal joints simultaneously in the second attempt with the patient under anesthesia. On confirming the stability of the reduction, the foot was immobilized in a short-leg, posterior slab cast for 3 weeks without placing Kirschner wires across the joints. At the 3-month follow-up evaluation, the patient had reacquired their preinjury level of activity with a good range of motion . At the 2-year follow-up evaluation, this range of motion was maintained with no radiologic evidence of arthrosis. We have inferred that the reduction was successful the second time because the maneuver freed the soft tissue structures from the contiguous impingement in the metatarsophalangeal joints by the exact reversal of the mode of injury using simultaneous application of the maneuver to all the lesser metatarsophalangeal joints. We encourage a trial of this modification of the closed reduction method in the emergency setting before proceeding to open reduction, because the results of closed reduction can be biologically rewarding without the risks associated with open surgical dissection. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Single-user MIMO versus multi-user MIMO in distributed antenna systems with limited feedback

    NASA Astrophysics Data System (ADS)

    Schwarz, Stefan; Heath, Robert W.; Rupp, Markus

    2013-12-01

    This article investigates the performance of cellular networks employing distributed antennas in addition to the central antennas of the base station. Distributed antennas are likely to be implemented using remote radio units, which is enabled by a low latency and high bandwidth dedicated link to the base station. This facilitates coherent transmission from potentially all available antennas at the same time. Such distributed antenna system (DAS) is an effective way to deal with path loss and large-scale fading in cellular systems. DAS can apply precoding across multiple transmission points to implement single-user MIMO (SU-MIMO) and multi-user MIMO (MU-MIMO) transmission. The throughput performance of various SU-MIMO and MU-MIMO transmission strategies is investigated in this article, employing a Long-Term evolution (LTE) standard compliant simulation framework. The previously theoretically established cell-capacity improvement of MU-MIMO in comparison to SU-MIMO in DASs is confirmed under the practical constraints imposed by the LTE standard, even under the assumption of imperfect channel state information (CSI) at the base station. Because practical systems will use quantized feedback, the performance of different CSI feedback algorithms for DASs is investigated. It is shown that significant gains in the CSI quantization accuracy and in the throughput of especially MU-MIMO systems can be achieved with relatively simple quantization codebook constructions that exploit the available temporal correlation and channel gain differences.

  13. Entirely soft dielectric elastomer robots

    NASA Astrophysics Data System (ADS)

    Henke, E.-F. Markus; Wilson, Katherine E.; Anderson, Iain A.

    2017-04-01

    Multifunctional Dielectric Elastomer (DE) devices are well established as actuators, sensors and energy har- vesters. Since the invention of the Dielectric Elastomer Switch (DES), a piezoresistive electrode that can directly switch charge on and off, it has become possible to expand the wide functionality of DE structures even more. We show the application of fully soft DE subcomponents in biomimetic robotic structures. It is now possible to couple arrays of actuator/switch units together so that they switch charge between them- selves on and off. One can then build DE devices that operate as self-controlled oscillators. With an oscillator one can produce a periodic signal that controls a soft DE robot - a DE device with its own DE nervous system. DESs were fabricated using a special electrode mixture, and imprinting technology at an exact pre-strain. We have demonstrated six orders of magnitude change in conductivity within the DES over 50% strain. The control signal can either be a mechanical deformation from another DE or an electrical input to a connected dielectric elastomer actuator (DEA). We have demonstrated a variety of fully soft multifunctional subcomponents that enable the design of autonomous soft robots without conventional electronics. The combination of digital logic structures for basic signal processing, data storage in dielectric elastomer flip-flops and digital and analogue clocks with adjustable frequencies, made of dielectric elastomer oscillators (DEOs), enables fully soft, self-controlled and electronics-free robotic structures. DE robotic structures to date include stiff frames to maintain necessary pre-strains enabling sufficient actuation of DEAs. Here we present a design and production technology for a first robotic structure consisting only of soft silicones and carbon black.

  14. Effect of Al-Si Coating on Weld Microstructure and Properties of 22MnB5 Steel Joints for Hot Stamping

    NASA Astrophysics Data System (ADS)

    Lin, Wenhu; Li, Fang; Wu, Dongsheng; Chen, Xiaoguan; Hua, Xueming; Pan, Hua

    2018-03-01

    22MnB5 hot stamping steels are gradually being used in tailor-welded blank applications. In this experiment, 1-mm-thick Al-Si coated and de-coated 22MnB5 steels were laser-welded and then hot-stamped. The chemical compositions, solidification process, microstructure and mechanical properties were investigated to reveal the effect of Al-Si coating and heat treatment. In the welded condition, the coated joints had an Al content of approximately 2.5 wt.% in the fusion zone and the de-coated joints had 0.5 wt.% Al. The aluminum promoted the δ-ferrite formation as the skeletal structure during solidification. In the high-aluminum weld, the microstructure consisted of martensite and long and band-like δ-ferrite. Meanwhile, the low-aluminum weld was full of lath martensite. After the hot stamping process, the δ-ferrite fraction increased from 10 to 24% in the coated joints and the lath martensite became finer in the de-coated joints. The tensile strengths of the coated joints or de-coated joints were similar to that before hot stamping, but the strength of the coated joints was reduced heavily after hot stamping compared to the de-coated joints and base material. The effect of δ-ferrite on the tensile properties became stronger when the fusion zone was soft and deformed first in the hot-stamped specimens. The coated weld showed a brittle fracture surface with many cleavage planes, and the de-coated weld showed a ductile fracture surface with many dimples in hot-stamped conditions.

  15. Introductory physics going soft

    NASA Astrophysics Data System (ADS)

    Langbeheim, Elon; Livne, Shelly; Safran, Samuel A.; Yerushalmi, Edit

    2012-01-01

    We describe an elective course on soft matter at the level of introductory physics. Soft matter physics serves as a context that motivates the presentation of basic ideas in statistical thermodynamics and their applications. It also is an example of a contemporary field that is interdisciplinary and touches on chemistry, biology, and physics. We outline a curriculum that uses the lattice gas model as a quantitative and visual tool, initially to introduce entropy, and later to facilitate the calculation of interactions. We demonstrate how free energy minimization can be used to teach students to understand the properties of soft matter systems such as the phases of fluid mixtures, wetting of interfaces, self-assembly of surfactants, and polymers. We discuss several suggested activities in the form of inquiry projects which allow students to apply the concepts they have learned to experimental systems.

  16. Facial Soft Tissue Trauma

    PubMed Central

    Kretlow, James D.; McKnight, Aisha J.; Izaddoost, Shayan A.

    2010-01-01

    Traumatic facial soft tissue injuries are commonly encountered in the emergency department by plastic surgeons and other providers. Although rarely life-threatening, the treatment of these injuries can be complex and may have significant impact on the patient's facial function and aesthetics. This article provides a review of the relevant literature related to this topic and describes the authors' approach to the evaluation and management of the patient with facial soft tissue injuries. PMID:22550459

  17. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    PubMed

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Soft Shoulders Ahead: Spurious Signatures of Soft and Partial Selective Sweeps Result from Linked Hard Sweeps

    PubMed Central

    Schrider, Daniel R.; Mendes, Fábio K.; Hahn, Matthew W.; Kern, Andrew D.

    2015-01-01

    Characterizing the nature of the adaptive process at the genetic level is a central goal for population genetics. In particular, we know little about the sources of adaptive substitution or about the number of adaptive variants currently segregating in nature. Historically, population geneticists have focused attention on the hard-sweep model of adaptation in which a de novo beneficial mutation arises and rapidly fixes in a population. Recently more attention has been given to soft-sweep models, in which alleles that were previously neutral, or nearly so, drift until such a time as the environment shifts and their selection coefficient changes to become beneficial. It remains an active and difficult problem, however, to tease apart the telltale signatures of hard vs. soft sweeps in genomic polymorphism data. Through extensive simulations of hard- and soft-sweep models, here we show that indeed the two might not be separable through the use of simple summary statistics. In particular, it seems that recombination in regions linked to, but distant from, sites of hard sweeps can create patterns of polymorphism that closely mirror what is expected to be found near soft sweeps. We find that a very similar situation arises when using haplotype-based statistics that are aimed at detecting partial or ongoing selective sweeps, such that it is difficult to distinguish the shoulder of a hard sweep from the center of a partial sweep. While knowing the location of the selected site mitigates this problem slightly, we show that stochasticity in signatures of natural selection will frequently cause the signal to reach its zenith far from this site and that this effect is more severe for soft sweeps; thus inferences of the target as well as the mode of positive selection may be inaccurate. In addition, both the time since a sweep ends and biologically realistic levels of allelic gene conversion lead to errors in the classification and identification of selective sweeps. This

  19. Soft shoulders ahead: spurious signatures of soft and partial selective sweeps result from linked hard sweeps.

    PubMed

    Schrider, Daniel R; Mendes, Fábio K; Hahn, Matthew W; Kern, Andrew D

    2015-05-01

    Characterizing the nature of the adaptive process at the genetic level is a central goal for population genetics. In particular, we know little about the sources of adaptive substitution or about the number of adaptive variants currently segregating in nature. Historically, population geneticists have focused attention on the hard-sweep model of adaptation in which a de novo beneficial mutation arises and rapidly fixes in a population. Recently more attention has been given to soft-sweep models, in which alleles that were previously neutral, or nearly so, drift until such a time as the environment shifts and their selection coefficient changes to become beneficial. It remains an active and difficult problem, however, to tease apart the telltale signatures of hard vs. soft sweeps in genomic polymorphism data. Through extensive simulations of hard- and soft-sweep models, here we show that indeed the two might not be separable through the use of simple summary statistics. In particular, it seems that recombination in regions linked to, but distant from, sites of hard sweeps can create patterns of polymorphism that closely mirror what is expected to be found near soft sweeps. We find that a very similar situation arises when using haplotype-based statistics that are aimed at detecting partial or ongoing selective sweeps, such that it is difficult to distinguish the shoulder of a hard sweep from the center of a partial sweep. While knowing the location of the selected site mitigates this problem slightly, we show that stochasticity in signatures of natural selection will frequently cause the signal to reach its zenith far from this site and that this effect is more severe for soft sweeps; thus inferences of the target as well as the mode of positive selection may be inaccurate. In addition, both the time since a sweep ends and biologically realistic levels of allelic gene conversion lead to errors in the classification and identification of selective sweeps. This

  20. Soft Thermal Sensor with Mechanical Adaptability.

    PubMed

    Yang, Hui; Qi, Dianpeng; Liu, Zhiyuan; Chandran, Bevita K; Wang, Ting; Yu, Jiancan; Chen, Xiaodong

    2016-11-01

    A soft thermal sensor with mechanical adaptability is fabricated by the combination of single-wall carbon nanotubes with carboxyl groups and self-healing polymers. This study demonstrates that this soft sensor has excellent thermal response and mechanical adaptability. It shows tremendous promise for improving the service life of soft artificial-intelligence robots and protecting thermally sensitive electronics from the risk of damage by high temperature. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Integrating soft sensor systems using conductive thread

    NASA Astrophysics Data System (ADS)

    Teng, Lijun; Jeronimo, Karina; Wei, Tianqi; Nemitz, Markus P.; Lyu, Geng; Stokes, Adam A.

    2018-05-01

    We are part of a growing community of researchers who are developing a new class of soft machines. By using mechanically soft materials (MPa modulus) we can design systems which overcome the bulk-mechanical mismatches between soft biological systems and hard engineered components. To develop fully integrated soft machines—which include power, communications, and control sub-systems—the research community requires methods for interconnecting between soft and hard electronics. Sensors based upon eutectic gallium alloys in microfluidic channels can be used to measure normal and strain forces, but integrating these sensors into systems of heterogeneous Young’s modulus is difficult due the complexity of finding a material which is electrically conductive, mechanically flexible, and stable over prolonged periods of time. Many existing gallium-based liquid alloy sensors are not mechanically or electrically robust, and have poor stability over time. We present the design and fabrication of a high-resolution pressure-sensor soft system that can transduce normal force into a digital output. In this soft system, which is built on a monolithic silicone substrate, a galinstan-based microfluidic pressure sensor is integrated with a flexible printed circuit board. We used conductive thread as the interconnect and found that this method alleviates problems arising due to the mechanical mismatch between conventional metal wires and soft or liquid materials. Conductive thread is low-cost, it is readily wetted by the liquid metal, it produces little bending moment into the microfluidic channel, and it can be connected directly onto the copper bond-pads of the flexible printed circuit board. We built a bridge-system to provide stable readings from the galinstan pressure sensor. This system gives linear measurement results between 500-3500 Pa of applied pressure. We anticipate that integrated systems of this type will find utility in soft-robotic systems as used for wearable

  2. Shear thinning in soft particle suspensions

    NASA Astrophysics Data System (ADS)

    Voudouris, Panayiotis; van der Zanden, Berco; Florea, Daniel; Fahimi, Zahra; Wyss, Hans

    2012-02-01

    Suspensions of soft deformable particles are encountered in a wide range of food and biological materials. Examples are biological cells, micelles, vesicles or microgel particles. While the behavior of suspenions of hard spheres - the classical model system of colloid science - is reasonably well understood, a full understanding of these soft particle suspensions remains elusive. The relation between single particle properties and macroscopic mechanical behavior still remains poorly understood in these materials. Here we examine the surprising shear thinning behavior that is observed in soft particle suspensions as a function of particle softness. We use poly-N-isopropylacrylamide (p-NIPAM) microgel particles as a model system to study this effect in detail. These soft spheres show significant shear thinning even at very large Peclet numbers, where this would not be observed for hard particles. The degree of shear thinning is directly related to the single particle elastic properties, which we characterize by the recently developed Capillary Micromechanics technique. We present a simple model that qualitatively accounts for the observed behavior.

  3. An electromechanical based deformable model for soft tissue simulation.

    PubMed

    Zhong, Yongmin; Shirinzadeh, Bijan; Smith, Julian; Gu, Chengfan

    2009-11-01

    Soft tissue deformation is of great importance to surgery simulation. Although a significant amount of research efforts have been dedicated to simulating the behaviours of soft tissues, modelling of soft tissue deformation is still a challenging problem. This paper presents a new deformable model for simulation of soft tissue deformation from the electromechanical viewpoint of soft tissues. Soft tissue deformation is formulated as a reaction-diffusion process coupled with a mechanical load. The mechanical load applied to a soft tissue to cause a deformation is incorporated into the reaction-diffusion system, and consequently distributed among mass points of the soft tissue. Reaction-diffusion of mechanical load and non-rigid mechanics of motion are combined to govern the simulation dynamics of soft tissue deformation. An improved reaction-diffusion model is developed to describe the distribution of the mechanical load in soft tissues. A three-layer artificial cellular neural network is constructed to solve the reaction-diffusion model for real-time simulation of soft tissue deformation. A gradient based method is established to derive internal forces from the distribution of the mechanical load. Integration with a haptic device has also been achieved to simulate soft tissue deformation with haptic feedback. The proposed methodology does not only predict the typical behaviours of living tissues, but it also accepts both local and large-range deformations. It also accommodates isotropic, anisotropic and inhomogeneous deformations by simple modification of diffusion coefficients.

  4. Decomposition of Fuzzy Soft Sets with Finite Value Spaces

    PubMed Central

    Jun, Young Bae

    2014-01-01

    The notion of fuzzy soft sets is a hybrid soft computing model that integrates both gradualness and parameterization methods in harmony to deal with uncertainty. The decomposition of fuzzy soft sets is of great importance in both theory and practical applications with regard to decision making under uncertainty. This study aims to explore decomposition of fuzzy soft sets with finite value spaces. Scalar uni-product and int-product operations of fuzzy soft sets are introduced and some related properties are investigated. Using t-level soft sets, we define level equivalent relations and show that the quotient structure of the unit interval induced by level equivalent relations is isomorphic to the lattice consisting of all t-level soft sets of a given fuzzy soft set. We also introduce the concepts of crucial threshold values and complete threshold sets. Finally, some decomposition theorems for fuzzy soft sets with finite value spaces are established, illustrated by an example concerning the classification and rating of multimedia cell phones. The obtained results extend some classical decomposition theorems of fuzzy sets, since every fuzzy set can be viewed as a fuzzy soft set with a single parameter. PMID:24558342

  5. Decomposition of fuzzy soft sets with finite value spaces.

    PubMed

    Feng, Feng; Fujita, Hamido; Jun, Young Bae; Khan, Madad

    2014-01-01

    The notion of fuzzy soft sets is a hybrid soft computing model that integrates both gradualness and parameterization methods in harmony to deal with uncertainty. The decomposition of fuzzy soft sets is of great importance in both theory and practical applications with regard to decision making under uncertainty. This study aims to explore decomposition of fuzzy soft sets with finite value spaces. Scalar uni-product and int-product operations of fuzzy soft sets are introduced and some related properties are investigated. Using t-level soft sets, we define level equivalent relations and show that the quotient structure of the unit interval induced by level equivalent relations is isomorphic to the lattice consisting of all t-level soft sets of a given fuzzy soft set. We also introduce the concepts of crucial threshold values and complete threshold sets. Finally, some decomposition theorems for fuzzy soft sets with finite value spaces are established, illustrated by an example concerning the classification and rating of multimedia cell phones. The obtained results extend some classical decomposition theorems of fuzzy sets, since every fuzzy set can be viewed as a fuzzy soft set with a single parameter.

  6. BACTERIOLOGICAL EXAMINATION OF SOFT DRINKS

    PubMed Central

    Stokes, William Royal

    1920-01-01

    Prohibition has boomed soft drinks so that more than ever there is need of rigid inspection. Dr. Stokes finds beverages with five-figure counts and empty “sterile” bottles always with some bacteria, sometimes with millions. This paper should attract the attention of health officers to their soft drink problems. PMID:18010284

  7. [Soft contactlenses in general practice (author's transl)].

    PubMed

    Miller, B

    1975-07-01

    In contrast to the hard lenses the soft lens has enough permeability for oxygen and water-soluble substances, whereas high molecular substances, bacteria and virus cannot penetrate the soft lenses, so long as their surfaces are intact. The two principal production methods, the spin cast method and the lathe-turned method are compared. The duration of wearing of the soft lens depends on the deposits of proteins from the tears on the surface of the lens and the desinfection method. The daily boiling of the lenses shortens their useful life, while chemical desinfection causes besides bacteriolysis, damage of the corneal cell protein. The new cleaners on the base of proteolytic plant enzymes promise good results. For the optical correction of astigmatism with more than 1 cyl, soft lenses with conic outer surface are used or combinations of a soft and a hard lens (Duosystem). The therapeutic use of soft lenses has as aim: protection of the cornea against mechanical irritation, release of pain, protracted administration output of medicaments. Further indications for use: aseptic corneal inflammation and corneal defects.

  8. Clover: Compiler directed lightweight soft error resilience

    DOE PAGES

    Liu, Qingrui; Lee, Dongyoon; Jung, Changhee; ...

    2015-05-01

    This paper presents Clover, a compiler directed soft error detection and recovery scheme for lightweight soft error resilience. The compiler carefully generates soft error tolerant code based on idem-potent processing without explicit checkpoint. During program execution, Clover relies on a small number of acoustic wave detectors deployed in the processor to identify soft errors by sensing the wave made by a particle strike. To cope with DUE (detected unrecoverable errors) caused by the sensing latency of error detection, Clover leverages a novel selective instruction duplication technique called tail-DMR (dual modular redundancy). Once a soft error is detected by either themore » sensor or the tail-DMR, Clover takes care of the error as in the case of exception handling. To recover from the error, Clover simply redirects program control to the beginning of the code region where the error is detected. Lastly, the experiment results demonstrate that the average runtime overhead is only 26%, which is a 75% reduction compared to that of the state-of-the-art soft error resilience technique.« less

  9. Experimental Research on Fatigue Failure for 2219-T6 Aluminum Alloy Friction Stir-Welded Joints

    NASA Astrophysics Data System (ADS)

    Sun, Guo-Qin; Niu, Jiang-Pei; Chen, Ya-Jing; Sun, Feng-Yang; Shang, De-Guang; Chen, Shu-Jun

    2017-08-01

    The fatigue experiment was executed for the 2219-T6 aluminum alloy friction stir-welded joints at the rotation speed of 800 r/min and the welding velocity of 150 mm/min. Most fatigue failures occurred in the weld nugget zone (WNZ), the thermo-mechanical affected zone and the nearby areas. The experimental results demonstrated that the sudden hardness gradient increases sites corresponding to the fatigue failure locations. The high-angle grain boundaries with the highest concentration were scattered within the WNZ. The microcracks initiated at the intersection of the soft grains. More than one crack initiation site was observed within the WNZ and the thermo-mechanical affected zone, when the fracture occurred in these areas. The rough surface of the welding area should be one of the main reasons for the fatigue failure occurrence. The fatigue crack growth rate in the WNZ at the first stage was fastest in comparison with the fatigue crack growth rate in the other areas of the joint.

  10. Water and fat separation in real-time MRI of joint movement with phase-sensitive bSSFP.

    PubMed

    Mazzoli, Valentina; Nederveen, Aart J; Oudeman, Jos; Sprengers, Andre; Nicolay, Klaas; Strijkers, Gustav J; Verdonschot, Nico

    2017-07-01

    To introduce a method for obtaining fat-suppressed images in real-time MRI of moving joints at 3 Tesla (T) using a bSSFP sequence with phase detection to enhance visualization of soft tissue structures during motion. The wrist and knee of nine volunteers were imaged with a real-time bSSFP sequence while performing dynamic tasks. For appropriate choice of sequence timing parameters, water and fat pixels showed an out-of-phase behavior, which was exploited to reconstruct water and fat images. Additionally, a 2-point Dixon sequence was used for dynamic imaging of the joints, and resulting water and fat images were compared with our proposed method. The joints could be visualized with good water-fat separation and signal-to-noise ratio (SNR), while maintaining a relatively high temporal resolution (5 fps in knee imaging and 10 fps in wrist imaging). The proposed method produced images of moving joints with higher SNR and higher image quality when compared with the Dixon method. Water-fat separation is feasible in real-time MRI of moving knee and wrist at 3 T. PS-bSSFP offers movies with higher SNR and higher diagnostic quality when compared with Dixon scans. Magn Reson Med 78:58-68, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Soft Active Materials for Actuation, Sensing, and Electronics

    NASA Astrophysics Data System (ADS)

    Kramer, Rebecca Krone

    Future generations of robots, electronics, and assistive medical devices will include systems that are soft and elastically deformable, allowing them to adapt their morphology in unstructured environments. This will require soft active materials for actuation, circuitry, and sensing of deformation and contact pressure. The emerging field of soft robotics utilizes these soft active materials to mimic the inherent compliance of natural soft-bodied systems. As the elasticity of robot components increases, the challenges for functionality revert to basic questions of fabrication, materials, and design - whereas such aspects are far more developed for traditional rigid-bodied systems. This thesis will highlight preliminary materials and designs that address the need for soft actuators and sensors, as well as emerging fabrication techniques for manufacturing stretchable circuits and devices based on liquid-embedded elastomers.

  12. Using taphonomy to infer differences in soft tissues between taxa: an example using basal and derived forms of Solnhofen pterosaurs.

    PubMed

    Beardmore, S R; Lawlor, E; Hone, D W E

    2017-08-01

    In fossilised vertebrates, the presence of soft tissues is the most obvious way to determine aspects of anatomy and functional morphology; however, occurrences are rare and other lines of evidence must be sought to indicate its extent and strength. For example, pterosaurs possessed a large wing membrane that enabled powered flight but other tissues are not widely preserved. A semi-quantitative analysis comparing skeletal articulation and completeness of the pterodactyloid Pterodactylus and non-pterodactyloid pterosaur Rhamphorhynchus from Solnhofen-type deposits implies there were anatomical differences between soft-tissue structure and attachments articulating skeletal joints of each. Typically, skeletons of Pterodactylus disarticulate to a greater extent than those of Rhamphorhynchus, which in turn suggests decay progressed to more advanced states in the former. However, this generalisation masks a mosaic of differences between different body parts, for example Rhamphorhynchus tends to lose the wings as complete units but retains a complete and still articulated tail in a greater number of specimens than Pterodactylus.

  13. Using taphonomy to infer differences in soft tissues between taxa: an example using basal and derived forms of Solnhofen pterosaurs

    NASA Astrophysics Data System (ADS)

    Beardmore, S. R.; Lawlor, E.; Hone, D. W. E.

    2017-08-01

    In fossilised vertebrates, the presence of soft tissues is the most obvious way to determine aspects of anatomy and functional morphology; however, occurrences are rare and other lines of evidence must be sought to indicate its extent and strength. For example, pterosaurs possessed a large wing membrane that enabled powered flight but other tissues are not widely preserved. A semi-quantitative analysis comparing skeletal articulation and completeness of the pterodactyloid Pterodactylus and non-pterodactyloid pterosaur Rhamphorhynchus from Solnhofen-type deposits implies there were anatomical differences between soft-tissue structure and attachments articulating skeletal joints of each. Typically, skeletons of Pterodactylus disarticulate to a greater extent than those of Rhamphorhynchus, which in turn suggests decay progressed to more advanced states in the former. However, this generalisation masks a mosaic of differences between different body parts, for example Rhamphorhynchus tends to lose the wings as complete units but retains a complete and still articulated tail in a greater number of specimens than Pterodactylus.

  14. A biomechanical evaluation to optimize the configuration of a hinged external fixator for the primary treatment of severely displaced intraarticular calcaneus fractures with soft tissue damage.

    PubMed

    Besch, Lutz; Schmidt, Ina; Mueller, Michael; Daniels-Wredenhagen, Mark; Hilgert, Ralf-Eric; Varoga, Deike; Seekamp, Andreas

    2008-01-01

    The purpose of this investigation was to develop an optimized hinged external fixator for the primary treatment of dislocated, intra-articular calcaneus fractures with associated soft tissue damage. To this end, a calcaneus model was made out of a polyurethane block, and a steel cylinder served as the ankle joint and was connected to a synthetic model of the tibia via a metal clamp. A saw cut served as the fracture in the model. A Steinmann nail and Schanz screw were placed in defined positions in the model and connected medially and laterally with longitudinal support rods. The fixator allowed a total of 20 degrees of plantar- and dorsiflexion, with rotation in the virtual axis of the upper ankle joint. Changes in the model fracture were measured during cyclical strain, and at different screw positions in the model tibia and calcaneus. Miniature force sensors located on the longitudinal support rods, and a plantar tension spring, were used to measure pressure and tension. Reproducible values were determined and, with the optimal configuration, shifting within the osteotomy was minimal. In the experimental configuration, optimal tibial screw placement was 70 mm proximal to the rotation axis of the upper ankle joint, and optimal placement of the Steinmann nail was in the posterior surface of the calcaneus. These findings indicated that the hinged fixator allows 20 degrees of ankle movement without alteration of the rotation axis, and suggest that this type of external fixator can be used in all types of calcaneal fracture regardless of the soft tissue damage. ACFAS Level of Clinical Evidence: 5c.

  15. Impact extractive fracture of jointed steel plates of a bolted joint

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.

    2012-08-01

    This study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of a bolted joint used in a car body. For the accurate prediction of crash characteristics of car bodies by computer-aided engineering (CAE), it is also necessary to examine the behavior and fracture of jointed steel plates subjected to impact loads. Although the actual impact fracture of jointed steel plates of a bolted joint used in cars is complicated, for simplifying the problem it might be classified into the shear fracture and the extractive fracture of jointed steel plates. Attention is given to the extractive fracture of jointed steel plates in this study. The extractive behavior and fracture of three kinds of steel plates used for cars are examined in experiments and numerical simulations. The impact extraction test of steel plates jointed by a bolt is performed using the one-bar method, together with the static test. In order to understand the mechanism of extractive fracture process of jointed steel plates, numerical simulations by a FEM code LS-DYNA are also carried out. The obtained results suggest that a stress-based fracture criterion may be developed for the impact extractive fracture of jointed steel plates of a bolted joint used in a car body.

  16. Can Soft Drink Taxes Reduce Population Weight?

    PubMed

    Fletcher, Jason M; Frisvold, David; Tefft, Nathan

    2010-01-01

    Soft drink consumption has been hypothesized as one of the major factors in the growing rates of obesity in the US. Nearly two-thirds of all states currently tax soft drinks using excise taxes, sales taxes, or special exemptions to food exemptions from sales taxes to reduce consumption of this product, raise revenue, and improve public health. In this paper, we evaluate the impact of changes in state soft drink taxes on body mass index (BMI), obesity, and overweight. Our results suggest that soft drink taxes influence BMI, but that the impact is small in magnitude.

  17. Can Soft Drink Taxes Reduce Population Weight?

    PubMed Central

    Fletcher, Jason M.; Frisvold, David

    2009-01-01

    Soft drink consumption has been hypothesized as one of the major factors in the growing rates of obesity in the US. Nearly two-thirds of all states currently tax soft drinks using excise taxes, sales taxes, or special exemptions to food exemptions from sales taxes to reduce consumption of this product, raise revenue, and improve public health. In this paper, we evaluate the impact of changes in state soft drink taxes on body mass index (BMI), obesity, and overweight. Our results suggest that soft drink taxes influence BMI, but that the impact is small in magnitude. PMID:20657817

  18. Glass transition of soft colloids

    NASA Astrophysics Data System (ADS)

    Philippe, Adrian-Marie; Truzzolillo, Domenico; Galvan-Myoshi, Julian; Dieudonné-George, Philippe; Trappe, Véronique; Berthier, Ludovic; Cipelletti, Luca

    2018-04-01

    We explore the glassy dynamics of soft colloids using microgels and charged particles interacting by steric and screened Coulomb interactions, respectively. In the supercooled regime, the structural relaxation time τα of both systems grows steeply with volume fraction, reminiscent of the behavior of colloidal hard spheres. Computer simulations confirm that the growth of τα on approaching the glass transition is independent of particle softness. By contrast, softness becomes relevant at very large packing fractions when the system falls out of equilibrium. In this nonequilibrium regime, τα depends surprisingly weakly on packing fraction, and time correlation functions exhibit a compressed exponential decay consistent with stress-driven relaxation. The transition to this novel regime coincides with the onset of an anomalous decrease in local order with increasing density typical of ultrasoft systems. We propose that these peculiar dynamics results from the combination of the nonequilibrium aging dynamics expected in the glassy state and the tendency of colloids interacting through soft potentials to refluidize at high packing fractions.

  19. Vibrio cholerae Colonization of Soft-Shelled Turtles

    PubMed Central

    Wang, Jiazheng; Yan, Meiying; Gao, He; Lu, Xin

    2017-01-01

    ABSTRACT Vibrio cholerae is an important human pathogen and environmental microflora species that can both propagate in the human intestine and proliferate in zooplankton and aquatic organisms. Cholera is transmitted through food and water. In recent years, outbreaks caused by V. cholerae-contaminated soft-shelled turtles, contaminated mainly with toxigenic serogroup O139, have been frequently reported, posing a new foodborne disease public health problem. In this study, the colonization by toxigenic V. cholerae on the body surfaces and intestines of soft-shelled turtles was explored. Preferred colonization sites on the turtle body surfaces, mainly the carapace and calipash of the dorsal side, were observed for the O139 and O1 strains. Intestinal colonization was also found. The colonization factors of V. cholerae played different roles in the colonization of the soft-shelled turtle's body surface and intestine. Mannose-sensitive hemagglutinin (MSHA) of V. cholerae was necessary for body surface colonization, but no roles were found for toxin-coregulated pili (TCP) or N-acetylglucosamine-binding protein A (GBPA). Both TCP and GBPA play important roles for colonization in the intestine, whereas the deletion of MSHA revealed only a minor colonization-promoting role for this factor. Our study demonstrated that V. cholerae can colonize the surfaces and the intestines of soft-shelled turtles and indicated that the soft-shelled turtles played a role in the transmission of cholera. In addition, this study showed that the soft-shelled turtle has potential value as an animal model in studies of the colonization and environmental adaption mechanisms of V. cholerae in aquatic organisms. IMPORTANCE Cholera is transmitted through water and food. Soft-shelled turtles contaminated with Vibrio cholerae (commonly the serogroup O139 strains) have caused many foodborne infections and outbreaks in recent years, and they have become a foodborne disease problem. Except for

  20. Vibrio cholerae Colonization of Soft-Shelled Turtles.

    PubMed

    Wang, Jiazheng; Yan, Meiying; Gao, He; Lu, Xin; Kan, Biao

    2017-07-15

    Vibrio cholerae is an important human pathogen and environmental microflora species that can both propagate in the human intestine and proliferate in zooplankton and aquatic organisms. Cholera is transmitted through food and water. In recent years, outbreaks caused by V. cholerae -contaminated soft-shelled turtles, contaminated mainly with toxigenic serogroup O139, have been frequently reported, posing a new foodborne disease public health problem. In this study, the colonization by toxigenic V. cholerae on the body surfaces and intestines of soft-shelled turtles was explored. Preferred colonization sites on the turtle body surfaces, mainly the carapace and calipash of the dorsal side, were observed for the O139 and O1 strains. Intestinal colonization was also found. The colonization factors of V. cholerae played different roles in the colonization of the soft-shelled turtle's body surface and intestine. Mannose-sensitive hemagglutinin (MSHA) of V. cholerae was necessary for body surface colonization, but no roles were found for toxin-coregulated pili (TCP) or N -acetylglucosamine-binding protein A (GBPA). Both TCP and GBPA play important roles for colonization in the intestine, whereas the deletion of MSHA revealed only a minor colonization-promoting role for this factor. Our study demonstrated that V. cholerae can colonize the surfaces and the intestines of soft-shelled turtles and indicated that the soft-shelled turtles played a role in the transmission of cholera. In addition, this study showed that the soft-shelled turtle has potential value as an animal model in studies of the colonization and environmental adaption mechanisms of V. cholerae in aquatic organisms. IMPORTANCE Cholera is transmitted through water and food. Soft-shelled turtles contaminated with Vibrio cholerae (commonly the serogroup O139 strains) have caused many foodborne infections and outbreaks in recent years, and they have become a foodborne disease problem. Except for epidemiological

  1. Computer-Based Instruction (CBI): Considerations for a User-Oriented Technology Data Base.

    DTIC Science & Technology

    1985-10-14

    CBI works primarily because of the systematic attention to instructional material it brings to the development process , and the extent to which quality...looked at CBI software multi-use potential, support and maintenance from a joint service perspective, and described requirements for a software...computer support for some aspect of the instructional process . Personnel involved in other TDAC projects are reviewing commercially available CBI and

  2. Hard evidence on soft skills.

    PubMed

    Heckman, James J; Kautz, Tim

    2012-08-01

    This paper summarizes recent evidence on what achievement tests measure; how achievement tests relate to other measures of "cognitive ability" like IQ and grades; the important skills that achievement tests miss or mismeasure, and how much these skills matter in life. Achievement tests miss, or perhaps more accurately, do not adequately capture, soft skills -personality traits, goals, motivations, and preferences that are valued in the labor market, in school, and in many other domains. The larger message of this paper is that soft skills predict success in life, that they causally produce that success, and that programs that enhance soft skills have an important place in an effective portfolio of public policies.

  3. Hard evidence on soft skills✩

    PubMed Central

    Heckman, James J.; Kautz, Tim

    2012-01-01

    This paper summarizes recent evidence on what achievement tests measure; how achievement tests relate to other measures of “cognitive ability” like IQ and grades; the important skills that achievement tests miss or mismeasure, and how much these skills matter in life. Achievement tests miss, or perhaps more accurately, do not adequately capture, soft skills—personality traits, goals, motivations, and preferences that are valued in the labor market, in school, and in many other domains. The larger message of this paper is that soft skills predict success in life, that they causally produce that success, and that programs that enhance soft skills have an important place in an effective portfolio of public policies. PMID:23559694

  4. Interventions for preventing lower limb soft-tissue running injuries.

    PubMed

    Yeung, Simon S; Yeung, Ella W; Gillespie, Lesley D

    2011-07-06

    Overuse soft-tissue injuries occur frequently in runners. Stretching exercises, modification of training schedules, and the use of protective devices such as braces and insoles are often advocated for prevention. This is an update of a review first published in 2001. To assess the effects of interventions for preventing lower limb soft-tissue running injuries. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (March 2011); The Cochrane Library 2010, Issue 4; MEDLINE (1966 to January 2011); EMBASE (1980 to January 2011); and international trial registries (17 January 2011). Randomised or quasi-randomised trials evaluating interventions to prevent lower limb soft-tissue running injuries. Two authors independently assessed risk of bias (relating to sequence generation, allocation concealment, blinding, incomplete outcome data) and extracted data. Data were adjusted for clustering if necessary and pooled using the fixed-effect model when appropriate. We included 25 trials (30,252 participants). Participants were military recruits (19 trials), runners from the general population (three trials), soccer referees (one trial), and prisoners (two trials). The interventions tested in the included trials fell into four main preventive strategies: exercises, modification of training schedules, use of orthoses, and footwear and socks. All 25 included trials were judged as 'unclear' or 'high' risk of bias for at least one of the four domains listed above.We found no evidence that stretching reduces lower limb soft-tissue injuries (6 trials; 5130 participants; risk ratio [RR] 0.85, 95% confidence interval [95% CI] 0.65 to 1.12). As with all non-significant results, this is compatible with either a reduction or an increase in soft-tissue injuries. We found no evidence to support a training regimen of conditioning exercises to improve strength, flexibility and coordination (one trial; 1020 participants; RR 1.20, 95% CI 0.77 to 1.87).We found no

  5. Measuring information transfer in a soft robotic arm.

    PubMed

    Nakajima, K; Schmidt, N; Pfeifer, R

    2015-05-13

    Soft robots can exhibit diverse behaviors with simple types of actuation by partially outsourcing control to the morphological and material properties of their soft bodies, which is made possible by the tight coupling between control, body, and environment. In this paper, we present a method that will quantitatively characterize these diverse spatiotemporal dynamics of a soft body based on the information-theoretic approach. In particular, soft bodies have the ability to propagate the effect of actuation through the entire body, with a certain time delay, due to their elasticity. Our goal is to capture this delayed interaction in a quantitative manner based on a measure called momentary information transfer. We extend this measure to soft robotic applications and demonstrate its power using a physical soft robotic platform inspired by the octopus. Our approach is illustrated in two ways. First, we statistically characterize the delayed actuation propagation through the body as a strength of information transfer. Second, we capture this information propagation directly as local information dynamics. As a result, we show that our approach can successfully characterize the spatiotemporal dynamics of the soft robotic platform, explicitly visualizing how information transfers through the entire body with delays. Further extension scenarios of our approach are discussed for soft robotic applications in general.

  6. Resonant soft X-ray scattering for polymer materials

    DOE PAGES

    Liu, Feng; Brady, Michael A.; Wang, Cheng

    2016-04-16

    Resonant Soft X-ray Scattering (RSoXS) was developed within the last few years, and the first dedicated resonant soft X-ray scattering beamline for soft materials was constructed at the Advanced Light Source, LBNL. RSoXS combines soft X-ray spectroscopy with X-ray scattering and thus offers statistical information for 3D chemical morphology over a large length scale range from nanometers to micrometers. Using RSoXS to characterize multi-length scale soft materials with heterogeneous chemical structures, we have demonstrated that soft X-ray scattering is a unique complementary technique to conventional hard X-ray and neutron scattering. Its unique chemical sensitivity, large accessible size scale, molecular bondmore » orientation sensitivity with polarized X-rays, and high coherence have shown great potential for chemically specific structural characterization for many classes of materials.« less

  7. Joint Instability and Osteoarthritis

    PubMed Central

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA. PMID:25741184

  8. Joint instability and osteoarthritis.

    PubMed

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  9. 3D printing for soft robotics – a review

    PubMed Central

    Gul, Jahan Zeb; Sajid, Memoon; Rehman, Muhammad Muqeet; Siddiqui, Ghayas Uddin; Shah, Imran; Kim, Kyung-Hwan; Lee, Jae-Wook; Choi, Kyung Hyun

    2018-01-01

    Abstract Soft robots have received an increasing attention due to their advantages of high flexibility and safety for human operators but the fabrication is a challenge. Recently, 3D printing has been used as a key technology to fabricate soft robots because of high quality and printing multiple materials at the same time. Functional soft materials are particularly well suited for soft robotics due to a wide range of stimulants and sensitive demonstration of large deformations, high motion complexities and varied multi-functionalities. This review comprises a detailed survey of 3D printing in soft robotics. The development of key 3D printing technologies and new materials along with composites for soft robotic applications is investigated. A brief summary of 3D-printed soft devices suitable for medical to industrial applications is also included. The growing research on both 3D printing and soft robotics needs a summary of the major reported studies and the authors believe that this review article serves the purpose. PMID:29707065

  10. The Natural-CCD Algorithm, a Novel Method to Solve the Inverse Kinematics of Hyper-redundant and Soft Robots.

    PubMed

    Martín, Andrés; Barrientos, Antonio; Del Cerro, Jaime

    2018-03-22

    This article presents a new method to solve the inverse kinematics problem of hyper-redundant and soft manipulators. From an engineering perspective, this kind of robots are underdetermined systems. Therefore, they exhibit an infinite number of solutions for the inverse kinematics problem, and to choose the best one can be a great challenge. A new algorithm based on the cyclic coordinate descent (CCD) and named as natural-CCD is proposed to solve this issue. It takes its name as a result of generating very harmonious robot movements and trajectories that also appear in nature, such as the golden spiral. In addition, it has been applied to perform continuous trajectories, to develop whole-body movements, to analyze motion planning in complex environments, and to study fault tolerance, even for both prismatic and rotational joints. The proposed algorithm is very simple, precise, and computationally efficient. It works for robots either in two or three spatial dimensions and handles a large amount of degrees-of-freedom. Because of this, it is aimed to break down barriers between discrete hyper-redundant and continuum soft robots.

  11. Soft Actuators for Small-Scale Robotics.

    PubMed

    Hines, Lindsey; Petersen, Kirstin; Lum, Guo Zhan; Sitti, Metin

    2017-04-01

    This review comprises a detailed survey of ongoing methodologies for soft actuators, highlighting approaches suitable for nanometer- to centimeter-scale robotic applications. Soft robots present a special design challenge in that their actuation and sensing mechanisms are often highly integrated with the robot body and overall functionality. When less than a centimeter, they belong to an even more special subcategory of robots or devices, in that they often lack on-board power, sensing, computation, and control. Soft, active materials are particularly well suited for this task, with a wide range of stimulants and a number of impressive examples, demonstrating large deformations, high motion complexities, and varied multifunctionality. Recent research includes both the development of new materials and composites, as well as novel implementations leveraging the unique properties of soft materials. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A Recipe for Soft Fluidic Elastomer Robots

    PubMed Central

    Marchese, Andrew D.; Katzschmann, Robert K.

    2015-01-01

    Abstract This work provides approaches to designing and fabricating soft fluidic elastomer robots. That is, three viable actuator morphologies composed entirely from soft silicone rubber are explored, and these morphologies are differentiated by their internal channel structure, namely, ribbed, cylindrical, and pleated. Additionally, three distinct casting-based fabrication processes are explored: lamination-based casting, retractable-pin-based casting, and lost-wax-based casting. Furthermore, two ways of fabricating a multiple DOF robot are explored: casting the complete robot as a whole and casting single degree of freedom (DOF) segments with subsequent concatenation. We experimentally validate each soft actuator morphology and fabrication process by creating multiple physical soft robot prototypes. PMID:27625913

  13. A Recipe for Soft Fluidic Elastomer Robots.

    PubMed

    Marchese, Andrew D; Katzschmann, Robert K; Rus, Daniela

    2015-03-01

    This work provides approaches to designing and fabricating soft fluidic elastomer robots. That is, three viable actuator morphologies composed entirely from soft silicone rubber are explored, and these morphologies are differentiated by their internal channel structure, namely, ribbed, cylindrical, and pleated. Additionally, three distinct casting-based fabrication processes are explored: lamination-based casting, retractable-pin-based casting, and lost-wax-based casting. Furthermore, two ways of fabricating a multiple DOF robot are explored: casting the complete robot as a whole and casting single degree of freedom (DOF) segments with subsequent concatenation. We experimentally validate each soft actuator morphology and fabrication process by creating multiple physical soft robot prototypes.

  14. Kennedy Space Center: Apollo to Multi-User Spaceport

    NASA Technical Reports Server (NTRS)

    Weber, Philip J.; Kanner, Howard S.

    2017-01-01

    future efforts of the transformation of the KSC Apollo and Space Shuttle heritage infrastructure into a more versatile, multi-user spaceport. The paper will also discuss the US Congressional and NASA initiatives for developing and supporting multiple commercial partners, while simultaneously supporting NASAs human exploration initiative, consisting of Space Launch System (SLS), Orion spacecraft and associated ground launch systems. In addition, the paper explains the approach with examples for NASA KSC to leverage new technologies and innovative capabilities developed to reduce the cost to individual users.

  15. Intake of high-fructose corn syrup sweetened soft drinks, fruit drinks and apple juice is associated with prevalent arthritis in US adults, aged 20-30 years.

    PubMed

    DeChristopher, L R; Uribarri, J; Tucker, K L

    2016-03-07

    There is a link between joint and gut inflammation of unknown etiology in arthritis. Existing research indicates that regular consumption of high-fructose corn syrup sweetened (HFCS) soft drinks, but not diet soft drinks, may be associated with increased risk of seropositive rheumatoid arthritis (RA) in women, independent of other dietary and lifestyle factors. One unexplored hypothesis for this association is that fructose malabsorption, due to regular consumption of excess free fructose (EFF) and HFCS, contributes to fructose reactivity in the gastrointestinal tract and intestinal in situ formation of enFruAGEs, which once absorbed, travel beyond the intestinal boundaries to other tissues and promote inflammation. In separate studies, the accumulation of advanced glycation end-products has been associated with joint inflammation in RA. Objective of this study was to assess the association between EFF beverages intake and non-age, non-wear and tear-associated arthritis in US young adults. In this cross sectional study of 1209 adults aged 20-30y, (Nutrition and Health Examination Surveys 2003-2006) exposure variables were high EFF beverages, including HFCS sweetened soft drinks, and any combination of HFCS sweetened soft drinks, fruit drinks (FD) and apple juice, referred to as tEFF. Analyses of diet soda and diet FD were included for comparison. The outcome was self-reported arthritis. Rao Scott Ҳ(2) was used for prevalence differences and logistic regression for associations, adjusted for confounders. Young adults consuming any combination of high EFF beverages (tEFF) ⩾5 times/week (but not diet soda) were three times as likely to have arthritis as non/low consumers (odds ratios=3.01; p⩽0.021; 95% confidence intervals=1.20-7.59), independent of all covariates, including physical activity, other dietary factors, blood glucose and smoking. EFF beverage intake is significantly associated with arthritis in US adults aged 20-30 years, possibly due to the

  16. Monolithic microfabricated valves and pumps by multilayer soft lithography.

    PubMed

    Unger, M A; Chou, H P; Thorsen, T; Scherer, A; Quake, S R

    2000-04-07

    Soft lithography is an alternative to silicon-based micromachining that uses replica molding of nontraditional elastomeric materials to fabricate stamps and microfluidic channels. We describe here an extension to the soft lithography paradigm, multilayer soft lithography, with which devices consisting of multiple layers may be fabricated from soft materials. We used this technique to build active microfluidic systems containing on-off valves, switching valves, and pumps entirely out of elastomer. The softness of these materials allows the device areas to be reduced by more than two orders of magnitude compared with silicon-based devices. The other advantages of soft lithography, such as rapid prototyping, ease of fabrication, and biocompatibility, are retained.

  17. From elasticity to capillarity in soft materials indentation

    NASA Astrophysics Data System (ADS)

    Pham, Jonathan T.; Schellenberger, Frank; Kappl, Michael; Butt, Hans-Jürgen

    2017-06-01

    For soft materials with Young's moduli below 100 kPa, quantifying mechanical and interfacial properties by small scale indentation is challenging because in addition to adhesion and elasticity, surface tension plays a critical role. Until now, microscale contact of very soft materials has only been studied by static experiments under zero external loading. Here we introduce a combination of the colloidal probe technique and confocal microscopy to characterize the force-indentation and force-contact radius relationships during microindentation of soft silicones. We confirm that the widespread Johnson-Kendall-Roberts theory must be extended to predict the mechanical contact for soft materials. Typically a liquid component is found within very soft materials. With a simple analytical model, we illustrate that accounting for this liquid surface tension can capture the contact behavior. Our results highlight the importance of considering liquid that is often associated with soft materials during small scale contact.

  18. Soft tissue modelling through autowaves for surgery simulation.

    PubMed

    Zhong, Yongmin; Shirinzadeh, Bijan; Alici, Gursel; Smith, Julian

    2006-09-01

    Modelling of soft tissue deformation is of great importance to virtual reality based surgery simulation. This paper presents a new methodology for simulation of soft tissue deformation by drawing an analogy between autowaves and soft tissue deformation. The potential energy stored in a soft tissue as a result of a deformation caused by an external force is propagated among mass points of the soft tissue by non-linear autowaves. The novelty of the methodology is that (i) autowave techniques are established to describe the potential energy distribution of a deformation for extrapolating internal forces, and (ii) non-linear materials are modelled with non-linear autowaves other than geometric non-linearity. Integration with a haptic device has been achieved to simulate soft tissue deformation with force feedback. The proposed methodology not only deals with large-range deformations, but also accommodates isotropic, anisotropic and inhomogeneous materials by simply changing diffusion coefficients.

  19. The SMILE Soft X-ray Imager (SXI) CCD design and development

    NASA Astrophysics Data System (ADS)

    Soman, M. R.; Hall, D. J.; Holland, A. D.; Burgon, R.; Buggey, T.; Skottfelt, J.; Sembay, S.; Drumm, P.; Thornhill, J.; Read, A.; Sykes, J.; Walton, D.; Branduardi-Raymont, G.; Kennedy, T.; Raab, W.; Verhoeve, P.; Agnolon, D.; Woffinden, C.

    2018-01-01

    SMILE, the Solar wind Magnetosphere Ionosphere Link Explorer, is a joint science mission between the European Space Agency and the Chinese Academy of Sciences. The spacecraft will be uniquely equipped to study the interaction between the Earth's magnetosphere-ionosphere system and the solar wind on a global scale. SMILE's instruments will explore this science through imaging of the solar wind charge exchange soft X-ray emission from the dayside magnetosheath, simultaneous imaging of the UV northern aurora and in-situ monitoring of the solar wind and magnetosheath plasma and magnetic field conditions. The Soft X-ray Imager (SXI) is the instrument being designed to observe X-ray photons emitted by the solar wind charge exchange process at photon energies between 200 eV and 2000 eV . X-rays will be collected using a focal plane array of two custom-designed CCDs, each consisting of 18 μm square pixels in a 4510 by 4510 array. SMILE will be placed in a highly elliptical polar orbit, passing in and out of the Earth's radiation belts every 48 hours. Radiation damage accumulated in the CCDs during the mission's nominal 3-year lifetime will degrade their performance (such as through decreases in charge transfer efficiency), negatively impacting the instrument's ability to detect low energy X-rays incident on the regions of the CCD image area furthest from the detector outputs. The design of the SMILE-SXI CCDs is presented here, including features and operating methods for mitigating the effects of radiation damage and expected end of life CCD performance. Measurements with a PLATO device that has not been designed for soft X-ray signal levels indicate a temperature-dependent transfer efficiency performance varying between 5×10-5 and 9×10-4 at expected End of Life for 5.9 keV photons, giving an initial set of measurements from which to extrapolate the performance of the SXI CCDs.

  20. Levitation properties of maglev systems using soft ferromagnets

    NASA Astrophysics Data System (ADS)

    Huang, Chen-Guang; Zhou, You-He

    2015-03-01

    Soft ferromagnets are widely used as flux-concentration materials in the design of guideways for superconducting magnetic levitation transport systems. In order to fully understand the influence of soft ferromagnets on the levitation performance, in this work we apply a numerical model based on the functional minimization method and the Bean’s critical state model to study the levitation properties of an infinitely long superconductor immersed in the magnetic field created by a guideway of different sets of infinitely long parallel permanent magnets with soft ferromagnets between them. The levitation force, guidance force, magnetic stiffness and magnetic pole density are calculated considering the coupling between the superconductor and soft ferromagnets. The results show that the levitation performance is closely associated with the permanent magnet configuration and with the location and dimension of the soft ferromagnets. Introducing the soft ferromagnet with a certain width in a few configurations always decreases the levitation force. However, for most configurations, the soft ferromagnets contribute to improve the levitation performance only when they have particular locations and dimensions in which the optimized location and thickness exist to increase the levitation force the most. Moreover, if the superconductor is laterally disturbed, the presence of soft ferromagnets can effectively improve the lateral stability for small lateral displacement and reduce the degradation of levitation force.