Sample records for joint thesaurus part

  1. NASA Thesaurus Supplement: A Three-Part Cumulative Update of the 1998 Edition of the NASA Thesaurus

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The NASA Thesaurus Supplement is a cumulative update to the 1998 edition of the NASA Thesaurus (NASA/SP-1998-7501). The Supplement, published every six months, includes all new terms and associated hierarchies added since the cutoff for the 1998 edition (December 1997). Parts 1 and 2 (Hierarchical Listing and Rotated Term Display) correspond to Volumes 1 and 2 of the 1998 printed edition of the NASA Thesaurus. Definitions are included in Part 1; uppercase/lowercase forms are provided in both Parts 1 and 2. Part 3 is a list of deletions or changes to valid terms.

  2. NASA Thesaurus Supplement: A three part cumulative supplement to the 1982 edition of the NASA Thesaurus (supplement 2)

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The three part cumulative NASA Thesaurus Supplement to the 1982 edition of the NASA Thesaurus includes: part 1, hierarchical listing; part 2, access vocabulary, and part 3, deletions. The semiannual supplement gives complete hierarchies for new terms and includes new term indications for terms new to this supplement.

  3. NASA Thesaurus Supplement: A three part cumulative supplement to the 1982 edition of the NASA Thesaurus (supplement 3)

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The three part cumulative NASA Thesaurus Supplement to the 1982 edition of the NASA Thesaurus includes Part 1, Hierarchical Listing, Part 2, Access Vocabulary, and Part 3, Deletions. The semiannual supplement gives complete hierarchies for new terms and includes new term indications for entries new to this supplement.

  4. NASA Thesaurus Supplement: A Three-Part Cumulative Update of the 1998 Edition of the NASA Thesaurus. Supplement 5

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The NASA Thesaurus Supplement is a cumulative update to the 1998 edition of the NASA Thesaurus (NASA/SP-1998-7501). The Supplement, published every 6 months, includes all new terms and associated hierarchies added since the cutoff for the 1998 edition (December 1997). Parts 1 and 2 (Hierarchical Listing and Rotated Term Display) correspond to Volumes 1 and 2 of the 1998 printed edition of the NASA Thesaurus. Definitions are included in Part 1; uppercase/lowercase forms are provided in both Parts 1 and 2. Part 3 is a list of deletions or changes to valid terms.

  5. NASA Thesaurus Supplement: A Three-Part Cumulative Update of the 1998 Edition of the NASA Thesaurus. Supplement 7

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The NASA Thesaurus Supplement is a cumulative update to the 1998 edition of the NASA Thesaurus (NASA/SP-1998-7501). The Supplement, published every six months, includes all new terms and associated hierarchies added since the cutoff for the 1998 edition (December 1997). Parts 1 and 2 (Hierarchical Listing and Rotated Term Display) correspond to Volumes 1 and 2 of the 1998 printed edition of the NASA Thesaurus. Definitions are included in Part 1; uppercase/lowercase forms are provided in both Parts 1 and 2. Part 3 is a list of deletions or changes to valid terms.

  6. NASA Thesaurus Supplement: A Three-Part Cumulative Update of the 1998 Edition of the NASA Thesaurus. Supplement 4

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The NASA Thesaurus Supplement is a cumulative update to the 1998 edition of the NASA Thesaurus (NASA/SP-1998-7501). The Supplement, published every six months, includes all new terms and associated hierarchies added since the cutoff for the 1998 edition (December 1997). Parts 1 and 2 (Hierarchical Listing and Rotated Term Display) correspond to Volumes 1 and 2 of the 1998 printed edition. Definitions are included in Part 1; uppercase/lowercase forms are provided in both Parts 1 and 2. Part 3 is a list of deletions or changes to valid terms.

  7. NASA Thesaurus supplement: A four part cumulative supplement to the 1988 edition of the NASA Thesaurus (supplement 3)

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The four-part cumulative supplement to the 1988 edition of the NASA Thesaurus includes the Hierarchical Listing (Part 1), Access Vocabulary (Part 2), Definitions (Part 3), and Changes (Part 4). The semiannual supplement gives complete hierarchies and accepted upper/lowercase forms for new terms.

  8. Flaw Tolerance in Lap Shear Brazed Joints. Part 1

    NASA Technical Reports Server (NTRS)

    Flom, Yury; Wang, Li-Qin

    2003-01-01

    Furnace brazing is a joining process used in the aerospace and other industries to produce strong permanent and hermetic structural joints. As in any joining process, brazed joints have various imperfections and defects. At the present time, our understanding of the influence of the internal defects on the strength of the brazed joints is not adequate. The goal of this 3-part investigation is to better understand the properties and failure mechanisms of the brazed joints containing defects. This study focuses on the behavior of the brazed lap shear joints because of their importance in manufacturing aerospace structures. In Part 1, an average shear strength capability and failure modes of the single lap joints are explored. Stainless steel specimens brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the failure loads and the ultimate shear strength with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap widths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. A damage zone criterion is shown to work quite well in understanding the failure of the braze joints. In Part 2, the findings of the Part 1 will be verified on the larger test specimens. Also, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify that behavior of the flawed ductile lap joints is similar to joints with a reduced braze area. Finally, in Part 3, the results obtained in Parts 1 and 2 will be applied to the actual brazed structure to evaluate the load-carrying capability of a structural lap joint containing discontinuities. In addition, a simplified engineering procedure will be offered for the laboratory testing of the lap shear specimens.

  9. Flaw Tolerance In Lap Shear Brazed Joints. Part 2

    NASA Technical Reports Server (NTRS)

    Wang, Len; Flom, Yury

    2003-01-01

    This paper presents results of the second part of an on-going effort to gain better understanding of defect tolerance in braze joints. In the first part of this three-part series, we mechanically tested and modeled the strength of the lap joints as a function of the overlap distance. A failure criterion was established based on the zone damage theory, which predicts the dependence of the lap joint shear strength on the overlap distance, based on the critical size of a finite damage zone or an overloaded region in the joint. In this second part of the study, we experimentally verified the applicability of the damage zone criterion on prediction of the shear strength of the lap joint and introduced controlled flaws into the lap joints. The purpose of the study was to evaluate the lap joint strength as a function of flaw size and its location through mechanical testing and nonlinear finite element analysis (FEA) employing damage zone criterion for definition of failure. The results obtained from the second part of the investigation confirmed that the failure of the ductile lap shear brazed joints occurs when the damage zone reaches approximately 10% of the overlap width. The same failure criterion was applicable to the lap joints containing flaws.

  10. A thesaurus for a neural population code

    PubMed Central

    Ganmor, Elad; Segev, Ronen; Schneidman, Elad

    2015-01-01

    Information is carried in the brain by the joint spiking patterns of large groups of noisy, unreliable neurons. This noise limits the capacity of the neural code and determines how information can be transmitted and read-out. To accurately decode, the brain must overcome this noise and identify which patterns are semantically similar. We use models of network encoding noise to learn a thesaurus for populations of neurons in the vertebrate retina responding to artificial and natural videos, measuring the similarity between population responses to visual stimuli based on the information they carry. This thesaurus reveals that the code is organized in clusters of synonymous activity patterns that are similar in meaning but may differ considerably in their structure. This organization is highly reminiscent of the design of engineered codes. We suggest that the brain may use this structure and show how it allows accurate decoding of novel stimuli from novel spiking patterns. DOI: http://dx.doi.org/10.7554/eLife.06134.001 PMID:26347983

  11. The NATO thesaurus project

    NASA Technical Reports Server (NTRS)

    Krueger, Jonathan

    1990-01-01

    This document describes functionality to be developed to support the NATO technical thesaurus. Described are the specificity of the thesaurus structure and function; the distinction between the thesaurus information and its representation in a given online, machine readable, or printed form; the enhancement of the thesaurus with the assignment of COSATI codes (fields and groups) to posting terms, the integration of DTIC DRIT and NASA thesauri related terminology, translation of posting terms into French; and the provision of a basis for system design.

  12. The QSPR-THESAURUS: the online platform of the CADASTER project.

    PubMed

    Brandmaier, Stefan; Peijnenburg, Willie; Durjava, Mojca K; Kolar, Boris; Gramatica, Paola; Papa, Ester; Bhhatarai, Barun; Kovarich, Simona; Cassani, Stefano; Roy, Partha Pratim; Rahmberg, Magnus; Öberg, Tomas; Jeliazkova, Nina; Golsteijn, Laura; Comber, Mike; Charochkina, Larisa; Novotarskyi, Sergii; Sushko, Iurii; Abdelaziz, Ahmed; D'Onofrio, Elisa; Kunwar, Prakash; Ruggiu, Fiorella; Tetko, Igor V

    2014-03-01

    The aim of the CADASTER project (CAse Studies on the Development and Application of in Silico Techniques for Environmental Hazard and Risk Assessment) was to exemplify REACH-related hazard assessments for four classes of chemical compound, namely, polybrominated diphenylethers, per and polyfluorinated compounds, (benzo)triazoles, and musks and fragrances. The QSPR-THESAURUS website (http: / /qspr-thesaurus.eu) was established as the project's online platform to upload, store, apply, and also create, models within the project. We overview the main features of the website, such as model upload, experimental design and hazard assessment to support risk assessment, and integration with other web tools, all of which are essential parts of the QSPR-THESAURUS. 2014 FRAME.

  13. Engineering studies on joint bar integrity, part II : finite element analysis

    DOT National Transportation Integrated Search

    2014-04-02

    This paper is the second in a two-part series describing : research sponsored by the Federal Railroad Administration : (FRA) to study the structural integrity of joint bars. In Part I, : observations from field surveys of joint bar inspections : cond...

  14. Quality Assurance of NCI Thesaurus by Mining Structural-Lexical Patterns

    PubMed Central

    Abeysinghe, Rashmie; Brooks, Michael A.; Talbert, Jeffery; Licong, Cui

    2017-01-01

    Quality assurance of biomedical terminologies such as the National Cancer Institute (NCI) Thesaurus is an essential part of the terminology management lifecycle. We investigate a structural-lexical approach based on non-lattice subgraphs to automatically identify missing hierarchical relations and missing concepts in the NCI Thesaurus. We mine six structural-lexical patterns exhibiting in non-lattice subgraphs: containment, union, intersection, union-intersection, inference-contradiction, and inference union. Each pattern indicates a potential specific type of error and suggests a potential type of remediation. We found 809 non-lattice subgraphs with these patterns in the NCI Thesaurus (version 16.12d). Domain experts evaluated a random sample of 50 small non-lattice subgraphs, of which 33 were confirmed to contain errors and make correct suggestions (33/50 = 66%). Of the 25 evaluated subgraphs revealing multiple patterns, 22 were verified correct (22/25 = 88%). This shows the effectiveness of our structurallexical-pattern-based approach in detecting errors and suggesting remediations in the NCI Thesaurus. PMID:29854100

  15. NASA Thesaurus. Volume 2: Access vocabulary

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The NASA Thesaurus -- Volume 2, Access Vocabulary -- contains an alphabetical listing of all Thesaurus terms (postable and nonpostable) and permutations of all multiword and pseudo-multiword terms. Also included are Other Words (non-Thesaurus terms) consisting of abbreviations, chemical symbols, etc. The permutations and Other Words provide 'access' to the appropriate postable entries in the Thesaurus.

  16. Experiences with the New TEST Thesaurus and the New NASA Thesaurus

    ERIC Educational Resources Information Center

    Rainey, Laura

    1970-01-01

    Paper presented at Special Libraries Association Annual Conference (Montreal, June 1969). A survey of 75 special libraries on use of the NASA Thesaurus and Thesaurus of Engineering and Scientific Terms (TEST). The findings reveal wide use and satisfaction with both. (JS)

  17. Australian transport index thesaurus

    DOT National Transportation Integrated Search

    2007-12-01

    This Thesaurus is designed to assist Australian librarians and researchers to access Australian and overseas : literature on transport and roads. Preferred terms have largely been chosen to reflect Australian usage. Terms : from the thesaurus are use...

  18. Torque Limit for Bolted Joint For Composites. Part B; Experimentation

    NASA Technical Reports Server (NTRS)

    Kostreva, Kristian M.

    2003-01-01

    Today, aerospace quality composite parts are generally made from either a unidirectional tape or a fabric prepreg form depending on the application. The matrix material, typically epoxy because of it dimensional stability, is pre-impregnated onto the fibers to ensure uniform distribution. Both of these composite forms are finding themselves used in applications where a joint is required. Two widely used joint methods are the classic mechanically fastened joint, and the contemporary bonded joint; however, the mechanically fastened joint is most commonly used by design engineers. A major portion of the research up-to-date about bolted composite joints has dealt with the inplane static load capacity. This work has helped to spawn standards dealing with filled-hole static joint strength. Other research has clearly shown that the clamp-up load in the mechanical fastener significantly affects the joint strength in a beneficial manner by reducing the bearing strength dependence of the composite laminate. One author reported a maximum increase in joint strength of 28%. This finding has helped to improve the reliability and efficiency of the joint in a composite structure.

  19. NASA Thesaurus. Volume 1: Alphabetical listing

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The NASA Thesaurus -- Volume 1, Alphabetical Listing -- contains all subject terms (postable and nonpostable) approved for use in the NASA scientific and technical information system. Included are the subject terms of the Preliminary Edition of the NASA Thesaurus (NASA SP-7030, December 1967); of the NASA Thesaurus Alphabetical Update (NASA SP-7040, September 1971); and terms approved, added or changed through May 31, 1975. Thesaurus structuring, including scope notes, a generic structure with broader-term/narrower-term (BT-NT) relationships displayed in embedded hierarchies, and other cross references, is provided for each term, as appropriate.

  20. Environmental/chemical thesaurus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shriner, C.R.; Dailey, N.S.; Jordan, A.C.

    The Environmental/Chemical Thesaurus approaches scientific language control problems from a multidisciplinary view. The Environmental/Biomedical Terminology Index (EBTI) was used as a base for the present thesaurus. The Environmental/Chemical Thesaurus, funded by the Environmental Protection Agency, used as its source of new terms those major terms found in 13 Environmental Protection Agency data bases. The scope of this thesaurus includes not only environmental and biomedical sciences, but also the physical sciences with emphasis placed on chemistry. Specific chemical compounds are not included; only classes of chemicals are given. To adhere to this level of classification, drugs and pesticides are identified bymore » class rather than by specific chemical name. An attempt was also made to expand the areas of sociology and economics. Terminology dealing with law, demography, and geography was expanded. Proper names of languages and races were excluded. Geographic terms were expanded to include proper names for oceans, continents, major lakes, rivers, and islands. Political divisions were added to allow for proper names of countries and states. With such a broad scope, terminology for specific sciences does not provide for indexing to the lowest levels in plant, animal, or chemical classifications.« less

  1. Development of Foreign Language Lexical Competence on the Basis of a Learner's Terminological Thesaurus and Dictionary

    ERIC Educational Resources Information Center

    Chainikova, Galina R.; Zatonskiy, Andrey V.; Mitiukov, Nicholas W.; Busygina, Helena L.

    2018-01-01

    The article suggests a method of foreign language lexical competence development on the basis of a Learner's terminological thesaurus and dictionary of software terms which includes four main components: classification part demonstrating the inner logic of the subject area, glossary with definitions of key terms, thesaurus demonstrating logical…

  2. NASA thesaurus. Volume 3: Definitions

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Publication of NASA Thesaurus definitions began with Supplement 1 to the 1985 NASA Thesaurus. The definitions given here represent the complete file of over 3,200 definitions, complimented by nearly 1,000 use references. Definitions of more common or general scientific terms are given a NASA slant if one exists. Certain terms are not defined as a matter of policy: common names, chemical elements, specific models of computers, and nontechnical terms. The NASA Thesaurus predates by a number of years the systematic effort to define terms, therefore not all Thesaurus terms have been defined. Nevertheless, definitions of older terms are continually being added. The following data are provided for each entry: term in uppercase/lowercase form, definition, source, and year the term (not the definition) was added to the NASA Thesaurus. The NASA History Office is the authority for capitalization in satellite and spacecraft names. Definitions with no source given were constructed by lexicographers at the NASA Scientific and Technical Information (STI) Facility who rely on the following sources for their information: experts in the field, literature searches from the NASA STI database, and specialized references.

  3. PARTS: Probabilistic Alignment for RNA joinT Secondary structure prediction

    PubMed Central

    Harmanci, Arif Ozgun; Sharma, Gaurav; Mathews, David H.

    2008-01-01

    A novel method is presented for joint prediction of alignment and common secondary structures of two RNA sequences. The joint consideration of common secondary structures and alignment is accomplished by structural alignment over a search space defined by the newly introduced motif called matched helical regions. The matched helical region formulation generalizes previously employed constraints for structural alignment and thereby better accommodates the structural variability within RNA families. A probabilistic model based on pseudo free energies obtained from precomputed base pairing and alignment probabilities is utilized for scoring structural alignments. Maximum a posteriori (MAP) common secondary structures, sequence alignment and joint posterior probabilities of base pairing are obtained from the model via a dynamic programming algorithm called PARTS. The advantage of the more general structural alignment of PARTS is seen in secondary structure predictions for the RNase P family. For this family, the PARTS MAP predictions of secondary structures and alignment perform significantly better than prior methods that utilize a more restrictive structural alignment model. For the tRNA and 5S rRNA families, the richer structural alignment model of PARTS does not offer a benefit and the method therefore performs comparably with existing alternatives. For all RNA families studied, the posterior probability estimates obtained from PARTS offer an improvement over posterior probability estimates from a single sequence prediction. When considering the base pairings predicted over a threshold value of confidence, the combination of sensitivity and positive predictive value is superior for PARTS than for the single sequence prediction. PARTS source code is available for download under the GNU public license at http://rna.urmc.rochester.edu. PMID:18304945

  4. Machine Aided Indexing and the NASA Thesaurus

    NASA Technical Reports Server (NTRS)

    vonOfenheim, Bill

    2007-01-01

    Machine Aided Indexing (MAI) is a Web-based application program for aiding the indexing of literature in the NASA Scientific and Technical Information (STI) Database. MAI was designed to be a convenient, fully interactive tool for determining the subject matter of documents and identifying keywords. The heart of MAI is a natural-language processor that accepts, as input, any user-supplied text, including abstracts, full documents, and Web pages. Within seconds, the text is analyzed and a ranked list of terms is generated. The 17,800 terms of the NASA Thesaurus serve as the foundation of the knowledge base used by MAI. The NASA Thesaurus defines a standard vocabulary, the use of which enables MAI to assist in ensuring that STI documents are uniformly and consistently accessible. Of particular interest to traditional users of the NASA Thesaurus, MAI incorporates a fully searchable thesaurus display module that affords word-search and hierarchy- navigation capabilities that make it much easier and less time-consuming to look up terms and browse, relative to lookup and browsing in older print and Portable Document Format (PDF) digital versions of the Thesaurus. In addition, because MAI is centrally hosted, the Thesaurus data are always current.

  5. Body Parts Dependent Joint Regressors for Human Pose Estimation in Still Images.

    PubMed

    Dantone, Matthias; Gall, Juergen; Leistner, Christian; Van Gool, Luc

    2014-11-01

    In this work, we address the problem of estimating 2d human pose from still images. Articulated body pose estimation is challenging due to the large variation in body poses and appearances of the different body parts. Recent methods that rely on the pictorial structure framework have shown to be very successful in solving this task. They model the body part appearances using discriminatively trained, independent part templates and the spatial relations of the body parts using a tree model. Within such a framework, we address the problem of obtaining better part templates which are able to handle a very high variation in appearance. To this end, we introduce parts dependent body joint regressors which are random forests that operate over two layers. While the first layer acts as an independent body part classifier, the second layer takes the estimated class distributions of the first one into account and is thereby able to predict joint locations by modeling the interdependence and co-occurrence of the parts. This helps to overcome typical ambiguities of tree structures, such as self-similarities of legs and arms. In addition, we introduce a novel data set termed FashionPose that contains over 7,000 images with a challenging variation of body part appearances due to a large variation of dressing styles. In the experiments, we demonstrate that the proposed parts dependent joint regressors outperform independent classifiers or regressors. The method also performs better or similar to the state-of-the-art in terms of accuracy, while running with a couple of frames per second.

  6. Instructional Materials Thesaurus for Special Education.

    ERIC Educational Resources Information Center

    Council for Exceptional Children, Reston, VA. Information Center on Exceptional Children.

    The thesaurus is intended to clarify and standardize terminology used to index instructional materials for exceptional children within the Special Education Instructional Materials Centers/Regional Media Centers Network. Although most of the approximately 1100 terms are descriptors selected from the thesaurus of the Educational Resources…

  7. Fabrication of Flex Joint Utilizing Additively Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Eddleman, David; Richard, Jim

    2015-01-01

    The Selective Laser Melting (SLM) manufacturing technique has been utilized in the manufacture of a flex joint typical of those found in rocket engine and main propulsion system ducting. The SLM process allowed for the combination of parts that are typically machined separately and welded together. This resulted in roughly a 65% reduction of the total number of parts, roughly 70% reduction in the total number of welds, and an estimated 60% reduction in the number of machining operations. The majority of the new design was in three SLM pieces. These pieces, as well as a few traditionally fabricated parts, were assembled into a complete unit, which has been pressure tested. The design and planned cryogenic testing of the unit will be presented.

  8. Synonym Success--Thanks to the Thesaurus

    ERIC Educational Resources Information Center

    Mountain, Lee

    2007-01-01

    After a class of ninth graders discovered the helpfulness of the thesaurus in such synonym activities as Synonym Tic-Tac-Toe and Cross-Synonym Puzzles, they started using the thesaurus to locate "the exactly right word" while drafting compositions. They also enriched their oral vocabularies during these activities by discussing synonyms from the…

  9. NASA Thesaurus Data File

    NASA Technical Reports Server (NTRS)

    2012-01-01

    The NASA Thesaurus contains the authorized NASA subject terms used to index and retrieve materials in the NASA Aeronautics and Space Database (NA&SD) and NASA Technical Reports Server (NTRS). The scope of this controlled vocabulary includes not only aerospace engineering, but all supporting areas of engineering and physics, the natural space sciences (astronomy, astrophysics, planetary science), Earth sciences, and the biological sciences. The NASA Thesaurus Data File contains all valid terms and hierarchical relationships, USE references, and related terms in machine-readable form. The Data File is available in the following formats: RDF/SKOS, RDF/OWL, ZThes-1.0, and CSV/TXT.

  10. Thesaurus Dataset of Educational Technology in Chinese

    ERIC Educational Resources Information Center

    Wu, Linjing; Liu, Qingtang; Zhao, Gang; Huang, Huan; Huang, Tao

    2015-01-01

    The thesaurus dataset of educational technology is a knowledge description of educational technology in Chinese. The aims of this thesaurus were to collect the subject terms in the domain of educational technology, facilitate the standardization of terminology and promote the communication between Chinese researchers and scholars from various…

  11. A Thesaurus-Linked Science Question-Banking System.

    ERIC Educational Resources Information Center

    Johnson, Sandra; Maher, Brian

    1984-01-01

    Outlines implementation and uses of the computerized question-banking system of the thesaurus-linked browse procedure used by APU National Assessment in Science Programme. The ROOT Thesaurus, a comprehensive indexing and searching tool for technological applications, is described and its modifications are discussed as the basis for the…

  12. NASA thesaurus combined file postings statistics

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The NASA Thesaurus Combined File Postings Statistics is published semiannually (January and July). This alphabetical listing of postable subject terms contained in the NASA Thesaurus is used to display the number of postings (documents) indexed by each subject term from 1968 to date. The postings totals per item are separated by announcement of other media into STAR, IAA, COSMIC, and OTHER, columnar entries covering the NASA document collection (1968 to date). This is a cumulative publication, and except for special cases, no reference is needed to previous issuances. Retention of the January 1992 issue could be helpful for book information. With the July 1992 issue, NALNET book statistics have been replaced by COSMIC statistics for NASA funded software. File postings statistics for the Alternate Data Base covering NASA collection from 1962 through 1967 were published on a one-time basis in September 1975. Subject terms for the Alternate Data Base are derived from the subject Authority List, reprinted 1985, which is available upon request. The distribution of 19,697,748 postings among the 17,446 NASA Thesaurus terms is tabulated on the last page of the NASA Thesaurus Combined File Postings Statistics.

  13. Circumstances of Trauma and Accidents in Children: A Thesaurus-based Survey

    PubMed

    Séjourné, Claire; Philbois, Olivier; Vercherin, Paul; Patural, Hugues

    2016-11-25

    Introduction : Injuries and accidents are major causes of morbidity and mortality in children in France. Identification and description of the mechanisms of accidents are essential to develop adapted prevention methods. For this purpose, a specific thesaurus of ICD-10 codes relating to the circumstances of trauma and accidents in children was created in the French Loire department. The objective of this study was to evaluate the relevance and acceptability of the thesaurus in the pediatric emergency unit of Saint-Etienne university hospital.Material and Methods : This study was conducted in two phases. The first, longitudinal phase was conducted over three periods between May and October 2014 to compare codings by emergency room physicians before using the thesaurus with those defined on the basis of the thesaurus. The second phase retrospectively compared coding in July and August 2014 before introduction of the thesaurus with thesaurus-based coding in July and August 2015.Results : The first phase showed a loss of more than half of the information without the thesaurus. The circumstances of trauma can be described by an appropriate code in more than 90% of cases. The second phase showed a 13% increase in coding of the circumstances of trauma, which nevertheless remains insufficient.Discussion : The thesaurus facilitates coding and generally meets the coding physician’s expectations and should be used in large-scale epidemiological surveys.

  14. CINAHL list of subject headings: a nursing thesaurus revised.

    PubMed

    Fishel, C C; Graham, K E; Greer, D M; Gupta, A D; Lockwood, D K; Prime, E E

    1985-04-01

    The rationale and methods for revising the thesaurus of one of the major health sciences indexing tools are discussed. Computer production of the Cumulative Index to Nursing & Allied Health Literature and the possibility of online access mandated a revision of the list of subject headings. CINAHL has maintained a policy of responding to user needs and to changes in the nursing and allied health literature, and user input was encouraged during revision of the thesaurus. The methods of structural revision are described, and major changes in the thesaurus are detailed. Modification of the thesaurus is expected to have a far-reaching impact on the retrieval of information in nursing and allied health. Nursing and Allied Health (CINAHL) is now available online through DIALOG (file 218) and BRS (access code NAHL).

  15. CINAHL list of subject headings: a nursing thesaurus revised.

    PubMed Central

    Fishel, C C; Graham, K E; Greer, D M; Gupta, A D; Lockwood, D K; Prime, E E

    1985-01-01

    The rationale and methods for revising the thesaurus of one of the major health sciences indexing tools are discussed. Computer production of the Cumulative Index to Nursing & Allied Health Literature and the possibility of online access mandated a revision of the list of subject headings. CINAHL has maintained a policy of responding to user needs and to changes in the nursing and allied health literature, and user input was encouraged during revision of the thesaurus. The methods of structural revision are described, and major changes in the thesaurus are detailed. Modification of the thesaurus is expected to have a far-reaching impact on the retrieval of information in nursing and allied health. Nursing and Allied Health (CINAHL) is now available online through DIALOG (file 218) and BRS (access code NAHL). PMID:3995203

  16. Engineering studies on joint bar integrity, part I : field surveys and observed failure modes

    DOT National Transportation Integrated Search

    2014-04-02

    This paper is the first of a two-part series describing a : research project, sponsored by the Federal Railroad : Administration (FRA), to study the structural integrity of joint : bars. In Part I of this series, observations from field surveys : con...

  17. Implementation of a thesaurus in an electronic photograph imaging system

    NASA Astrophysics Data System (ADS)

    Partlow, Denise

    1995-11-01

    A photograph imaging system presents a unique set of requirements for indexing and retrieving images, unlike a standard imaging system for written documents. This paper presents the requirements, technical design, and development results for a hierarchical ANSI standard thesaurus embedded into a photograph archival system. The thesaurus design incorporates storage reduction techniques, permits fast searches, and contains flexible indexing methods. It can be extended to many applications other than the retrieval of photographs. When photographic images are indexed into an electronic system, they are subject to a variety of indexing problems based on what the indexer `sees.' For instance, the indexer may categorize an image as a boat when others might refer to it as a ship, sailboat, or raft. The thesaurus will allow a user to locate images containing any synonym for boat, regardless of how the image was actually indexed. In addition to indexing problems, photos may need to be retrieved based on a broad category, for instance, flowers. The thesaurus allows a search for `flowers' to locate all images containing a rose, hibiscus, or daisy, yet still allow a specific search for an image containing only a rose. The technical design and method of implementation for such a thesaurus is presented. The thesaurus is implemented using an SQL relational data base management system that supports blobs, binary large objects. The design incorporates unique compression methods for storing the thesaurus words. Words are indexed to photographs using the compressed word and allow for very rapid searches, eliminating lengthy string matches.

  18. Auditing the NCI Thesaurus with Semantic Web Technologies

    PubMed Central

    Mougin, Fleur; Bodenreider, Olivier

    2008-01-01

    Auditing biomedical terminologies often results in the identification of inconsistencies and thus helps to improve their quality. In this paper, we present a method based on Semantic Web technologies for auditing biomedical terminologies and apply it to the NCI thesaurus. We stored the NCI thesaurus concepts and their properties in an RDF triple store. By querying this store, we assessed the consistency of both hierarchical and associative relations from the NCI thesaurus among themselves and with corresponding relations in the UMLS Semantic Network. We show that the consistency is better for associative relations than for hierarchical relations. Causes for inconsistency and benefits from using Semantic Web technologies for auditing purposes are discussed. PMID:18999265

  19. Auditing the NCI thesaurus with semantic web technologies.

    PubMed

    Mougin, Fleur; Bodenreider, Olivier

    2008-11-06

    Auditing biomedical terminologies often results in the identification of inconsistencies and thus helps to improve their quality. In this paper, we present a method based on Semantic Web technologies for auditing biomedical terminologies and apply it to the NCI thesaurus. We stored the NCI thesaurus concepts and their properties in an RDF triple store. By querying this store, we assessed the consistency of both hierarchical and associative relations from the NCI thesaurus among themselves and with corresponding relations in the UMLS Semantic Network. We show that the consistency is better for associative relations than for hierarchical relations. Causes for inconsistency and benefits from using Semantic Web technologies for auditing purposes are discussed.

  20. TESE--Thesaurus for Education Systems in Europe. English Version

    ERIC Educational Resources Information Center

    Eurydice, 2009

    2009-01-01

    The Thesaurus for Education Systems in Europe (TESE-2009 edition) is a multilingual thesaurus and a robust information retrieval tool focusing on European education systems and policies. It is specifically designed to cover the indexation needs of the Eurydice network and to facilitate information retrieval on Eurydice's central website. It can…

  1. Patient Education Thesaurus.

    ERIC Educational Resources Information Center

    Cooper, Lynn

    This thesaurus was compiled to make the materials in the Patient Education Room of the Donald J. Vincent Medical Library at Riverside Methodist Hospital, Columbus, Ohio, more accessible to patients. Subjects are grouped in fairly broad categories (e.g., Aging & Problems of Aging; Alcohol & Alcohol Abuse; Careers in the Medical Field; Childhood and…

  2. Understanding the Reliability of Solder Joints Used in Advanced Structural and Electronics Applications: Part 2 - Reliability Performance.

    DOE PAGES

    Vianco, Paul T.

    2017-03-01

    Whether structural or electronic, all solder joints must provide the necessary level of reliability for the application. The Part 1 report examined the effects of filler metal properties and the soldering process on joint reliability. Filler metal solderability and mechanical properties, as well as the extents of base material dissolution and interface reaction that occur during the soldering process, were shown to affect reliability performance. The continuation of this discussion is presented in this Part 2 report, which highlights those factors that directly affect solder joint reliability. There is the growth of an intermetallic compound (IMC) reaction layer at themore » solder/base material interface by means of solid-state diffusion processes. In terms of mechanical response by the solder joint, fatigue remains as the foremost concern for long-term performance. Thermal mechanical fatigue (TMF), a form of low-cycle fatigue (LCF), occurs when temperature cycling is combined with mismatched values of the coefficient of thermal expansion (CTE) between materials comprising the solder joint “system.” Vibration environments give rise to high-cycle fatigue (HCF) degradation. Although accelerated aging studies provide valuable empirical data, too many variants of filler metals, base materials, joint geometries, and service environments are forcing design engineers to embrace computational modeling to predict the long-term reliability of solder joints.« less

  3. Attribute And-Or Grammar for Joint Parsing of Human Pose, Parts and Attributes.

    PubMed

    Park, Seyoung; Nie, Xiaohan; Zhu, Song-Chun

    2017-07-25

    This paper presents an attribute and-or grammar (A-AOG) model for jointly inferring human body pose and human attributes in a parse graph with attributes augmented to nodes in the hierarchical representation. In contrast to other popular methods in the current literature that train separate classifiers for poses and individual attributes, our method explicitly represents the decomposition and articulation of body parts, and account for the correlations between poses and attributes. The A-AOG model is an amalgamation of three traditional grammar formulations: (i)Phrase structure grammar representing the hierarchical decomposition of the human body from whole to parts; (ii)Dependency grammar modeling the geometric articulation by a kinematic graph of the body pose; and (iii)Attribute grammar accounting for the compatibility relations between different parts in the hierarchy so that their appearances follow a consistent style. The parse graph outputs human detection, pose estimation, and attribute prediction simultaneously, which are intuitive and interpretable. We conduct experiments on two tasks on two datasets, and experimental results demonstrate the advantage of joint modeling in comparison with computing poses and attributes independently. Furthermore, our model obtains better performance over existing methods for both pose estimation and attribute prediction tasks.

  4. International Energy: Subject Thesaurus. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The International Energy Agency: Subject Thesaurus contains the standard vocabulary of indexing terms (descriptors) developed and structured to build and maintain energy information databases. Involved in this cooperative task are (1) the technical staff of the USDOE Office of Scientific and Technical Information (OSTI) in cooperation with the member countries of the International Energy Agency`s Energy Technology Data Exchange (ETDE) and (2) the International Atomic Energy Agency`s International Nuclear Information System (INIS) staff representing the more than 100 countries and organizations that record and index information for the international nuclear information community. ETDE member countries are also members of INIS.more » Nuclear information prepared for INIS by ETDE member countries is included in the ETDE Energy Database, which contains the online equivalent of the printed INIS Atomindex. Indexing terminology is therefore cooperatively standardized for use in both information systems. This structured vocabulary reflects thscope of international energy research, development, and technological programs. The terminology of this thesaurus aids in subject searching on commercial systems, such as ``Energy Science & Technology`` by DIALOG Information Services, ``Energy`` by STN International and the ``ETDE Energy Database`` by SilverPlatter. It is also the thesaurus for the Integrated Technical Information System (ITIS) online databases of the US Department of Energy.« less

  5. NASA thesaurus alphabetical update: Subject terms for indexing scientific and technical information

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The NASA THESAURUS - ALPHABETICAL UPDATE is an alphabetical listing of all subject terms (postable and nonpostable) that are currently approved for use in the NASA scientific and technical information system. Contained in the listing are the subject terms that were listed in the Preliminary Edition of the NASA THESAURUS and the additional subject terms that were approved during the period January 1, 1967 June 30, 1971. Complete Thesaurus structuring, including scope notes, category assignments, and cross-references, is provided for each term as appropriate.

  6. Australian Thesaurus of Education Descriptors. A Word-Stock for Indexing and Retrieving Australian Educational Literature.

    ERIC Educational Resources Information Center

    Lavender, G. B.; Findlay, Margaret A.

    This core thesaurus of terms suitable for indexing Australian educational literature was developed by the Australian Council for Educational Research by means of a systematic and thorough revision of the "Thesaurus of ERIC Descriptors." Based on the actual terminology of education in Australia, this thesaurus includes: key words and…

  7. Toward a Bio-Medical Thesaurus: Building the Foundation of the UMLS

    PubMed Central

    Tuttle, Mark S.; Blois, Marsden S.; Erlbaum, Mark S.; Nelson, Stuart J.; Sherertz, David D.

    1988-01-01

    The Unified Medical Language System (UMLS) is being designed to provide a uniform user interface to heterogeneous machine-readable bio-medical information resources, such as bibliographic databases, genetic databases, expert systems and patient records.1 Such an interface will have to recognize different ways of saying the same thing, and provide links to ways of saying related things. One way to represent the necessary associations is via a domain thesaurus. As no such thesaurus exists, and because, once built, it will be both sizable and in need of continuous maintenance, its design should include a methodology for building and maintaining it. We propose a methodology, utilizing lexically expanded schema inversion, and a design, called T. Lex, which together form one approach to the problem of defining and building a bio-medical thesaurus. We argue that the semantic locality implicit in such a thesaurus will support model-based reasoning in bio-medicine.2

  8. NICEM Thesaurus. First Edition.

    ERIC Educational Resources Information Center

    National Information Center for Educational Media, Albuquerque, NM.

    This thesaurus, developed by the National Information Center for Educational Media (NICEM), represents an expansion of the NICEM subject headings list, which is designed to provide access to a database of bibliographical records of nonprint, educational media. A preface discusses the issues that led to a revamping of the subject headings,…

  9. Evaluation Thesaurus. Second Edition.

    ERIC Educational Resources Information Center

    Scriven, Michael

    This thesaurus to the evaluation field is not restricted to educational evaluation or to program evaluation, but also refers to product, personnel, and proposal evaluation, as well as to quality control, the grading of work samples, and to all the other areas in which disciplined evaluation is practiced. It contains many suggestions, procedures,…

  10. IEDA Thesaurus: A Controlled Vocabulary for IEDA Systems to Advance Integration

    NASA Astrophysics Data System (ADS)

    Ji, P.; Lehnert, K. A.; Arko, R. A.; Song, L.; Hsu, L.; Carter, M. R.; Ferrini, V. L.; Ash, J.

    2014-12-01

    Integrated Earth Data Applications (IEDA) is a community-based facility that serves to support, sustain, and advance the geosciences by providing data services for observational geoscience data from the Ocean, Earth, and Polar Sciences. Many dedicated systems such as the Petrological Database (PetDB), Marine Geoscience Data System (MGDS), System for Earth Sample Registration (SESAR), Data Coordination Center for the U.S. Antarctic Program (USAP-DCC), etc., under the umbrella of the IEDA framework, were developed to support the preservation, discovery, retrieval, and analysis of a wide range of observational field and analytical data types from diverse communities. However, it is currently difficult to maintain consistency of indexing content within IEDA schema, and perform unified or precise searching of the data in these diverse systems as each system maintains separate vocabularies, hierarchies, authority files, or sub taxonomies. We present here the IEDA Thesaurus, a system, which combines existing separate controlled vocabularies from the different systems under the IEDA schema into a single master controlled vocabulary, also introducing some new top facets for future long-term use. The IEDA thesaurus contains structured terminology for petrology, geochemistry, sedimentology, oceanography, geochronology, and volcanology, and other general metadata fields. 18 top facets (also called 'top categories') are defined, including equipment, geographic gazetteer, geologic ages, geologic units, materials, etc. The terms of the thesaurus are cross validated with others popular geoscience vocabularies such as GeoRef Thesaurus, U.S. Geological Survey Library Classification System, Global Change Master Directory (GCMD), and Semantic Web for Earth and Environmental Terminology (SWEET) ontologies. The thesaurus is organized along with the ANSI/NISO Z39.19-2005 Guidelines for the Construction, Format, and Management of Monolingual Controlled Vocabularies, and is published using

  11. Evaluation Thesaurus. Third Edition.

    ERIC Educational Resources Information Center

    Scriven, Michael

    This is a thesaurus of terms used in evaluation. It is not restricted in scope to educational or program evaluation. It refers to product and personnel and proposal evaluation as well as to quality control and the grading of work samples. The text contains practical suggestions and procedures, comments and criticisms, as well as definitions and…

  12. A Thesaurus for Information Technology and Education. Occasional Paper ITE/6/86.

    ERIC Educational Resources Information Center

    Lewis, R.

    Prepared for use by the Information Technology and Education (ITE) Programme of the Economic and Social Science Research Council (ESRC), this draft document is based on the 1984 EUDISED (European Documentation and Information System for Education) Thesaurus for Information Processing. This draft is a modified thesaurus which aims to keep as close…

  13. Rotary Joints With Electrical Connections

    NASA Technical Reports Server (NTRS)

    Osborn, F. W.

    1986-01-01

    Power and data transmitted on many channels. Two different rotary joints equipped with electrical connections between rotating and stationary parts. One joint transmits axial thrust and serves as interface between spinning and nonspinning parts of Galileo spacecraft. Other is scanning (limitedrotation) joint that aims scientific instruments from nonspinning part. Selected features of both useful to designers of robots, advanced production equipment, and remotely controlled instruments.

  14. Defense Technical Information Center Thesaurus

    DTIC Science & Technology

    2000-10-01

    acquisition radar 4 + Indicates existence of further generic levels of the term DTIC Thesaurus Actuators Acridines Actinide series (cont.) Activated sintering...BT Heterocyclic compounds+ Uranium+ BT Sintering Acrilan Actinide series compounds Activated sludge process use Acrylonitrile polymers RT Actinide...Waste treatment+ Protactinium compounds Acronyms Thorium compounds+ Activation use Abbreviations Transuranium compounds+ UF Energizing Uranium compounds

  15. [Temporo-mandibular joint. Morpho-functional considerations].

    PubMed

    Scutariu, M D; Indrei, Anca

    2004-01-01

    The temporo-mandibular joint is distinguished from most other synovial joints of the body by two features: 1. the two jointed components carry teeth whose position and occlusion introduce a very strong influence on the movements of the temporo-mandibular joint and 2. its articular surfaces are not covered by hyaline cartilage, but by a dense, fibrous tissue. This paper describes the parts of the temporo-mandibular joint: the articular surfaces (the condylar process of the mandible and the glenoid part of the temporal bone), the fibrocartilaginous disc which is interposed between the mandibular and the temporal surface, the fibrous capsule of the temporo-mandibular joint and the ligaments of this joint. All these parts present a very strong adaptation at the important functions of the temporo-mandibular joint.

  16. Defense Technical Information Center thesaurus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dickert, J.H.

    This DTIC Thesaurus provides a basic multidisciplinary subject term vocabulary used by DTIC to index and retrieve scientific and technical information from its various data bases and to aid DTIC`s users in their information storage and retrieval operations. It includes an alphabetical posting term display, a hierarchy display, and a Keywork Out of Context (KWOC) display.

  17. Thesaurus for Special Education Instructional Materials.

    ERIC Educational Resources Information Center

    Dailey, Rebecca; And Others

    The thesaurus is intended as a preliminary standardization and clarification of terms used to index special education instructional materials throughout the Special Education Instructional Materials Centers/Regional Media Centers (IMC/RMC) Network. The majority of entries are approved descriptors appearing in the selected standard, the Thesaurus…

  18. An electronic thesaurus of Evidence Based Laboratory Medicine hematological and biochemical diagnostic tests.

    PubMed

    Dorizzi, R M; Maconi, M; Giavarina, D; Loza, G; Aman, M; Moreira, J; Bisoffi, Z; Gennuso, C

    2009-10-01

    The adoption of Evidence Based Laboratory Medicine (EBLM) has been hampered until today by the lack of effective tools. The SIMeL EBLM e-Thesaurus (on-line Repertoire of the diagnostic effectiveness of the laboratory, radiology and cardiology test) provides a useful support to clinical laboratory professionals and to clinicians for the interpretation of the diagnostic tests. The e-Thesaurus is an application developed using Microsoft Active Server Pages technology and carried out with Web Server Microsoft Internet Information Server and is available at the SIMeL website using a browser running JavaScript scripts (Internet Explorer is recommended). It contains a database (in Italian, English and Spanish) of the sensitivity and specificity (including the 95% confidence interval), the positive and negative likelihood ratios, the Diagnostic Odds Ratio and the Number Needed to Diagnose of more than 2000 diagnostic (most laboratory but also cardiology and radiology) tests. The e-Thesaurus improves the previous SIMeL paper and CD Thesaurus; its main features are a three languages search and a continuous and an easy updating capability.

  19. NASA thesaurus: Astronomy vocabulary

    NASA Technical Reports Server (NTRS)

    1988-01-01

    A terminology of descriptors used by the NASA Scientific and Technical information effort to index documents in the area of astronomy is presented. The terms are listed in hierarchical format derived from the 1988 edition of the NASA Thesaurus Volume 1 -- Hierarchical Listing. Over 1600 terms are included. In addition to astronomy, space sciences covered include astrophysics, cosmology, lunar flight and exploration, meteors and meteorites, celestial mechanics, planetary flight and exploration, and planetary science.

  20. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  1. Creation of a master table for checking indication and contraindication of medicine from a knowledge base linked with a thesaurus.

    PubMed

    Ji, Shanmei; Matsumura, Yasushi; Kuwata, Shigeki; Nakano, Hirohiko; Chen, Yufeng; Teratani, Tadamasa; Zhang, Qiyan; Mineno, Takahiro; Takeda, Hiroshi

    2004-12-01

    To develop a system for checking indication and contraindication of medicines in prescription order entry system, a master table consisting of the disease names corresponding to the medicines adopted in a hospital is needed. The creation of this table requires a considerable manpower. We developed a Web-based system for constructing a medicine/disease thesaurus and a knowledge base. By authority management of users, this system enables many specialists to create the thesaurus collaboratively without confusion. It supports the creation of a knowledge base using concept names by referring to the thesaurus, which is automatically converted to the check master table. When a disease name or medicine name was added to the thesaurus, the check table was automatically updated. We constructed a thesaurus and a knowledge base in the field of circulatory system disease. The knowledge base linked with the thesaurus proved to be efficient for making the check master table for indication/contraindication of medicines.

  2. Longitudinal joint study.

    DOT National Transportation Integrated Search

    2001-09-01

    In previous years there has been a problem with longitudinal joint : deterioration, due in part to poor construction techniques. : The degradation of the longitudinal joints has increased the cost of : maintaining these projects and caused unnecessar...

  3. NASA thesaurus aeronautics vocabulary

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The controlled vocabulary used by the NASA Scientific and Technical Information effort to index documents in the area of aeronautics is presented. The terms comprise a subset of the 1988 edition of the NASA Thesaurus and its supplements issued through the end of 1990. The Aeronautics Vocabulary contains over 4700 terms presented in a hierarchical display format. In addition to aeronautics per se, the vocabulary covers supporting terminology from areas such as fluid dynamics, propulsion engineering, and test facilities and instrumentation.

  4. Use of NLM medical subject headings with the MeSH2010 thesaurus in the PORTAL-DOORS system.

    PubMed

    Taswell, Carl

    2010-01-01

    The NLM MeSH Thesaurus has been incorporated for use in the PORTAL-DOORS System (PDS) for resource metadata management on the semantic web. All 25588 descriptor records from the NLM 2010 MeSH Thesaurus have been exposed as web accessible resources by the PDS MeSH2010 Thesaurus implemented as a PDS PORTAL Registry operating as a RESTful web service. Examples of records from the PDS MeSH2010 PORTAL are demonstrated along with their use by records in other PDS PORTAL Registries that reference the concepts from the MeSH2010 Thesaurus. Use of this important biomedical terminology will greatly enhance the quality of metadata content of other PDS records thus improving cross-domain searches between different problem oriented domains and amongst different clinical specialty fields.

  5. European Training Thesaurus: A Multilingual Synopsis

    ERIC Educational Resources Information Center

    Cedefop - European Centre for the Development of Vocational Training, 2012

    2012-01-01

    Education and training issues are similar across Europe, but how can we ensure we mean the same things with the same terms? The new format of the European training thesaurus (ETT) is a multilingual synopsis. It is an online tool enabling those working in education, training and employment to have a common understanding of terms. It helps…

  6. Joint with application in electrochemical devices

    DOEpatents

    Weil, K Scott [Richland, WA; Hardy, John S [Richland, WA

    2010-09-14

    A joint for use in electrochemical devices, such as solid oxide fuel cells (SOFCs), oxygen separators, and hydrogen separators, that will maintain a hermetic seal at operating temperatures of greater than 600.degree. C., despite repeated thermal cycling excess of 600.degree. C. in a hostile operating environment where one side of the joint is continuously exposed to an oxidizing atmosphere and the other side is continuously exposed to a wet reducing gas. The joint is formed of a metal part, a ceramic part, and a flexible gasket. The flexible gasket is metal, but is thinner and more flexible than the metal part. As the joint is heated and cooled, the flexible gasket is configured to flex in response to changes in the relative size of the metal part and the ceramic part brought about by differences in the coefficient of thermal expansion of the metal part and the ceramic part, such that substantially all of the tension created by the differences in the expansion and contraction of the ceramic and metal parts is absorbed and dissipated by flexing the flexible gasket.

  7. Costs and Their Assessment to Users of a Medical Library, Part III: Allocating Fixed Joint Costs.

    ERIC Educational Resources Information Center

    Bres, E.; And Others

    Part III of the study describes a model for completing the cost assessment (justification) process by accounting for the fixed joint costs; a "fair" and equitable mechanism is developed in the context of game-theoretic approach. An n-person game is constructed in which the "players" are the institutions served by the library,…

  8. Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation.

    PubMed

    Frick, Eric; Rahmatalla, Salam

    2018-04-04

    The biomechanical models used to refine and stabilize motion capture processes are almost invariably driven by joint center estimates, and any errors in joint center calculation carry over and can be compounded when calculating joint kinematics. Unfortunately, accurate determination of joint centers is a complex task, primarily due to measurements being contaminated by soft-tissue artifact (STA). This paper proposes a novel approach to joint center estimation implemented via sequential application of single-frame optimization (SFO). First, the method minimizes the variance of individual time frames’ joint center estimations via the developed variance minimization method to obtain accurate overall initial conditions. These initial conditions are used to stabilize an optimization-based linearization of human motion that determines a time-varying joint center estimation. In this manner, the complex and nonlinear behavior of human motion contaminated by STA can be captured as a continuous series of unique rigid-body realizations without requiring a complex analytical model to describe the behavior of STA. This article intends to offer proof of concept, and the presented method must be further developed before it can be reasonably applied to human motion. Numerical simulations were introduced to verify and substantiate the efficacy of the proposed methodology. When directly compared with a state-of-the-art inertial method, SFO reduced the error due to soft-tissue artifact in all cases by more than 45%. Instead of producing a single vector value to describe the joint center location during a motion capture trial as existing methods often do, the proposed method produced time-varying solutions that were highly correlated ( r > 0.82) with the true, time-varying joint center solution.

  9. Hip joint replacement - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The hip joint is made up of two major parts: ...

  10. NASA Thesaurus. Volumes 1 and 2; Hierarchical Listing with Definitions; Rotated Term Display

    NASA Technical Reports Server (NTRS)

    2012-01-01

    The NASA Thesaurus contains the authorized subject terms by which the documents in the NASA STI Databases are indexed and retrieved. The scope of this controlled vocabulary includes not only aerospace engineering, but all supporting areas of engineering and physics, the natural space sciences (astronomy, astrophysics, planetary science), Earth sciences, and to some extent, the biological sciences. Volume 1 - Hierarchical Listing With Definitions contains over 18,400 subject terms, 4,300 definitions, and more than 4,500 USE cross references. The Hierarchical Listing presents full hierarchical structure for each term along with 'related term' lists, and can serve as an orthographic authority. Volume 2 - Rotated Term Display is a ready-reference tool which provides over 52,700 additional 'access points' to the thesaurus terminology. It contains the postable and nonpostable terms found in the Hierarchical Listing arranged in a KWIC (key-word-in-context) index. This CD-ROM version of the NASA Thesaurus is in PDF format and is updated to the current year of purchase.

  11. Preliminary Evaluation of an Aviation Safety Thesaurus' Utility for Enhancing Automated Processing of Incident Reports

    NASA Technical Reports Server (NTRS)

    Barrientos, Francesca; Castle, Joseph; McIntosh, Dawn; Srivastava, Ashok

    2007-01-01

    This document presents a preliminary evaluation the utility of the FAA Safety Analytics Thesaurus (SAT) utility in enhancing automated document processing applications under development at NASA Ames Research Center (ARC). Current development efforts at ARC are described, including overviews of the statistical machine learning techniques that have been investigated. An analysis of opportunities for applying thesaurus knowledge to improving algorithm performance is then presented.

  12. The NCI Thesaurus quality assurance life cycle.

    PubMed

    de Coronado, Sherri; Wright, Lawrence W; Fragoso, Gilberto; Haber, Margaret W; Hahn-Dantona, Elizabeth A; Hartel, Francis W; Quan, Sharon L; Safran, Tracy; Thomas, Nicole; Whiteman, Lori

    2009-06-01

    The National Cancer Institute Enterprise Vocabulary Services (NCI EVS) uses a wide range of quality assurance (QA) techniques to maintain and extend NCI Thesaurus (NCIt). NCIt is a reference terminology and biomedical ontology used in a growing number of NCI and other systems that extend from translational and basic research through clinical care to public information and administrative activities. Both automated and manual QA techniques are employed throughout the editing and publication cycle, which includes inserting and editing NCIt in NCI Metathesaurus. NCI EVS conducts its own additional periodic and ongoing content QA. External reviews, and extensive evaluation by and interaction with EVS partners and other users, have also played an important part in the QA process. There have always been tensions and compromises between meeting the needs of dependent systems and providing consistent and well-structured content; external QA and feedback have been important in identifying and addressing such issues. Currently, NCI EVS is exploring new approaches to broaden external participation in the terminology development and QA process.

  13. Educatee's Thesaurus as an Object of Measuring Learned Material of the Distance Learning Course

    ERIC Educational Resources Information Center

    Rybanov, Alexander Aleksandrovich

    2013-01-01

    Monitoring and control over the process of studying the distance learning course are based on solving the problem of making out an adequate integral mark to the educatee for mastering entire study course, by testing results. It is suggested to use the degree of correspondence between educatee's thesaurus and the study course thesaurus as an…

  14. Understanding the reliability of solder joints used in advanced structural and electronics applications: Part 1 - Filler metal properties and the soldering process

    DOE PAGES

    Vianco, Paul T.

    2017-02-01

    Soldering technology has made tremendous strides in the past half-century. Whether structural or electronic, all solder joints must provide a level of reliability that is required by the application. This Part 1 report examines the effects of filler metal properties and soldering process on joint reliability. Solder alloy composition must have the appropriate melting and mechanical properties that suit the product's assembly process(es) and use environment. The filler metal must also optimize solderability (wetting-and-spreading) to realize the proper joint geometry. Here, the soldering process also affects joint reliability. The choice of flux and thermal profile support the solderability performance ofmore » the molten filler metal to successfully fill the gap and complete the fillet.« less

  15. Developing a New Thesaurus for Art and Architecture.

    ERIC Educational Resources Information Center

    Petersen, Toni

    1990-01-01

    This description of the development of the Art and Architecture Thesaurus from 1979 to the present explains the processes and policies that were used to construct a language designed to represent knowledge in art and architecture, as well as to be a surrogate for the image and object being described. (EAM)

  16. Occupational exposure factors for mental and behavioral disorders at work: The FOREC thesaurus.

    PubMed

    Chamoux, Alain; Lambert, Céline; Vilmant, Audrey; Lanhers, Charlotte; Agius, Raymond; Boutaleb, Mounir; Bonneterre, Vincent; Naughton, Geraldine; Pereira, Bruno; Djeriri, Khalid; Ben-Brik, Eric; Breton, Christine; De Clavière, Caroline; Letheux, Corinne; Paolillo, Anne-Gaëlle; Valenty, Madeleine; Vandenberghe, Odile; Aeschlimann, Marie-Pierre; Lasfargues, Gérard; Lesage, Francois-Xavier; Dutheil, Frédéric

    2018-01-01

    Mental disorders in the workplace are a major public health problem. Knowledge of the impact of the psychosocial work environment on mental and behavioral disorders can assist occupational physicians in the identification and description of occupational risk situations, and help to define priority actions. However, no classification for occupational exposure factors is currently available. We aimed to build a thesaurus of "Organizational, Relational, Ethical and other Contributing Factors" (FOREC) linked with the onset of mental and behavioral disorders. The French Agency for Food, Environmental and Occupational Health and Safety (ANSES) initiated and supervised a multidisciplinary working group consisting of the representatives of the main French occupational and public health actors. All decisions were accepted on a consensus basis. This collaborative work led to the classification of occupational exposure factors for mental and behavioral disorders in the workplace. To test this thesaurus in clinical practice, a French multicenter study was implemented. Patients were workers referred to the Occupational Disease Centers for mental health issues at work. Factors contributing to mental and behavioral disorders among workers were identified and coded retrospectively from the worker's point of view using the FOREC thesaurus. We recruited 323 workers, aged 44.9±9.2 years, of which 31.3% were men. The most commonly encountered disorders were generalized anxiety disorders (106 workers, 32.8%) and moderate depressive episodes (86 workers, 26.7%). We identified 1357 factors, i.e. an average of 4.2 factors per worker. Among them, 575 (42.4%) were relational and 515 (37.9%) were organizational. All factors identified during consultations were described in the thesaurus. We built the first thesaurus of "Organizational, Relational, Ethical and other Contributing Factors" (FOREC) that may help to generate profiles of mental and behavioral disorders at work. Encoding and

  17. A Method for Search Engine Selection using Thesaurus for Selective Meta-Search Engine

    NASA Astrophysics Data System (ADS)

    Goto, Shoji; Ozono, Tadachika; Shintani, Toramatsu

    In this paper, we propose a new method for selecting search engines on WWW for selective meta-search engine. In selective meta-search engine, a method is needed that would enable selecting appropriate search engines for users' queries. Most existing methods use statistical data such as document frequency. These methods may select inappropriate search engines if a query contains polysemous words. In this paper, we describe an search engine selection method based on thesaurus. In our method, a thesaurus is constructed from documents in a search engine and is used as a source description of the search engine. The form of a particular thesaurus depends on the documents used for its construction. Our method enables search engine selection by considering relationship between terms and overcomes the problems caused by polysemous words. Further, our method does not have a centralized broker maintaining data, such as document frequency for all search engines. As a result, it is easy to add a new search engine, and meta-search engines become more scalable with our method compared to other existing methods.

  18. Self-Alining Quick-Connect Joint

    NASA Technical Reports Server (NTRS)

    Lucy, M. H.

    1983-01-01

    Quick connect tapered joint used with minimum manipulation and force. Split ring retainer holds locking ring in place. Minimal force required to position male in female joint, at which time split-ring retainers are triggered to release split locking rings. Originally developed to assemble large space structures, joint is simple, compact, strong, lightweight, self alining, and has no loose parts.

  19. Resolving Quasi-Synonym Relationships in Automatic Thesaurus Construction Using Fuzzy Rough Sets and an Inverse Term Frequency Similarity Function

    ERIC Educational Resources Information Center

    Davault, Julius M., III.

    2009-01-01

    One of the problems associated with automatic thesaurus construction is with determining the semantic relationship between word pairs. Quasi-synonyms provide a type of equivalence relationship: words are similar only for purposes of information retrieval. Determining such relationships in a thesaurus is hard to achieve automatically. The term…

  20. The Joint Chiefs of Staff and National Policy Volume III 1950-1951, The Korean War: Part One,

    DTIC Science & Technology

    1998-01-01

    National Policy Volume III 1950-1951 The Korean War Part One James F . Schnabel Robert J. Watson Office of Joint History Office of the Chairman...transferred to other du- ties, Mr. James F . Schnabel assumed responsibility for the volume and planned, Foreword researched, and wrote the...into publishable form. JAMES F . SCHNABEL ROBERT J.WATSON vm Contents 1. Korea in US Policy, 1945-1950 1 The Partition of Korea 1 Establishment

  1. Quick-connect threaded attachment joint

    NASA Technical Reports Server (NTRS)

    Lucy, M. H.; Messick, W. R.; Vasquez, P.

    1979-01-01

    Joint is self-aligning and tightens with only sixty-five degrees of rotation for quick connects and disconnects. Made of injection-molded plastics or cast or machined aluminum, joint can carry wires, tubes, liquids, or gases. When two parts of joint are brought together, their shapes align them. Small projections on male section and slots on female section further aid alignment; slight rotation of male form engages projections in slots. At this point, threads engage and male section is rotated until joint is fully engaged.

  2. Motor impairments related to brain injury timing in early hemiparesis. Part II: abnormal upper extremity joint torque synergies.

    PubMed

    Sukal-Moulton, Theresa; Krosschell, Kristin J; Gaebler-Spira, Deborah J; Dewald, Julius P A

    2014-01-01

    Extensive neuromotor development occurs early in human life, and the timing of brain injury may affect the resulting motor impairment. In Part I of this series, it was demonstrated that the distribution of weakness in the upper extremity depended on the timing of brain injury in individuals with childhood-onset hemiparesis. The goal of this study was to characterize how timing of brain injury affects joint torque synergies, or losses of independent joint control. Twenty-four individuals with hemiparesis were divided into 3 groups based on the timing of their injury: before birth (PRE-natal, n = 8), around the time of birth (PERI-natal, n = 8), and after 6 months of age (POST-natal, n = 8). Individuals with hemiparesis and 8 typically developing peers participated in maximal isometric shoulder, elbow, wrist, and finger torque generation tasks while their efforts were recorded by a multiple degree-of-freedom load cell. Motor output in 4 joints of the upper extremity was concurrently measured during 8 primary torque generation tasks to quantify joint torque synergies. There were a number of significant coupling patterns identified in individuals with hemiparesis that differed from the typically developing group. POST-natal differences were most noted in the coupling of shoulder abductors with elbow, wrist, and finger flexors, while the PRE-natal group demonstrated significant distal joint coupling with elbow flexion. The torque synergies measured provide indirect evidence for the use of bulbospinal pathways in the POST-natal group, while those with earlier injury may use relatively preserved ipsilateral corticospinal motor pathways.

  3. Riveting in metal airplane construction. Part IV : strength of riveted joints in duralumin (concluded)

    NASA Technical Reports Server (NTRS)

    Pleines, Wilhelm

    1930-01-01

    Tests were made to determine the crushing strength of a riveted joint, in order to define the difference in crushing stregth between a strictly bolted joint and a riveted joint. The object was to tabulate the crushing strength by failure on various plate thicknesses for a one-rivet double-shear riveted joint.

  4. Articular cartilage. Part II. The osteoarthritic joint.

    PubMed

    Muehleman, C; Arsenis, C H

    1995-05-01

    Articular hyaline cartilage, though a metabolically active tissue, has limited capacity for repair. Though the integrity of the cartilage is dependent upon a certain level of force placed upon it, excessive force leads to damage. It is when the breakdown of the cartilage exceeds the capacity of the cartilage for repair that osteoarthritis results. At present, pharmacologic treatment of osteoarthritis is focused toward the control of pain and stiffness. This treatment, however, masks the symptoms of the disease and effectively allows the patient to do further damage to the joint.

  5. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, J.V.; Novak, R.F.; McBride, J.R.

    1991-08-27

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system. 11 figures.

  6. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, John V.; Novak, Robert F.; McBride, James R.

    1991-01-01

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system.

  7. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    PubMed Central

    Avgoulas, Evangelos I.; Sutcliffe, Michael P. F.

    2016-01-01

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints. PMID:28773688

  8. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints.

    PubMed

    Avgoulas, Evangelos I; Sutcliffe, Michael P F

    2016-07-12

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  9. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Joint ownership. 583.15 Section 583.15 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint...

  10. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Joint ownership. 583.15 Section 583.15 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint...

  11. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Joint ownership. 583.15 Section 583.15 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint...

  12. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Joint ownership. 583.15 Section 583.15 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint...

  13. Fluoroscopic Sacroiliac Joint Injection: Is Oblique Angulation Really Necessary?

    PubMed

    Khuba, Sandeep; Agarwal, Anil; Gautam, Sujeet; Kumar, Sanjay

    2016-01-01

    The conventional technique for sacroiliac (SI) joint injection involves aligning the anterior and posterior aspects of the SI joint under fluoroscopic guidance and then entering the SI joint in the most caudal aspect. We wish to highlight that there is no added advantage to aligning both the anterior and posterior joint lines of the SI joint as it is time consuming, associated with additional radiation exposure, and may make the entry into the posterior SI joint technically more difficult. Observational study. Pain Clinic, Department of Anesthesiology. With the patient lying prone on fluoroscopy table, SI joint injection is performed with a 22 G, 10 cm spinal needle in a true anteroposterior (AP) view, where anterior and posterior SI joint spaces are seen as separate entities, where the medial joint space represents the posterior SI joint and the lateral joint space represents the anterior SI joint. The distal 1 cm of the medial joint space is entered under AP view. If the SI joint is seen as a straight line rather than 2 joint spaces in the AP view then the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint, thus facilitating entry into this part of the joint which was confirmed by administering 0.3 to 0.5 mL of radiopaque contrast medium. Sixty SI joints of 58 patients were injected under an AP fluoroscopic view. Forty-two (70%) SI joints were seen as 2 separate medial and lateral joint spaces and were entered in distal 1 cm of the medial joint space. In 18 (30%) joints seen as a straight line rather than 2 separate spaces, the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint and then the SI joint was entered in its distal 1 cm. Confirmation of entry into the SI joint was confirmed by with 0.3 to 0.5 mL of radiopaque contrast medium. In 4 cases the joints did not show the correct radiopaque contrast spread (3/42 and 1

  14. Construction of the NASA Thesaurus: Computer Processing Support. Final Report.

    ERIC Educational Resources Information Center

    Hammond, William

    Details are given on the necessary computer processing services required to produce a NASA thesaurus. These services included (1) keypunching the terminology to specifications from approximately 19,000 Term Review Forms furnished by NASA; (2) modifying a set of programs to satisfy NASA specifications, principally to accommodate 42 character terms…

  15. A Proposal for a Thesaurus for Web Services in Solar Radiation

    NASA Technical Reports Server (NTRS)

    Gschwind, Benoit; Menard, Lionel; Ranchin, Thierry; Wald, Lucien; Stackhouse, Paul W., Jr.

    2007-01-01

    Metadata are necessary to discover, describe and exchange any type of information, resource and service at a large scale. A significant amount of effort has been made in the field of geography and environment to establish standards. Efforts still remain to address more specific domains such as renewable energies. This communication focuses on solar energy and more specifically on aspects in solar radiation that relate to geography and meteorology. A thesaurus in solar radiation is proposed for the keys elements in solar radiation namely time, space and radiation types. The importance of time-series in solar radiation is outlined and attributes of the key elements are discussed. An XML schema for encoding metadata is proposed. The exploitation of such a schema in web services is discussed. This proposal is a first attempt at establishing a thesaurus for describing data and applications in solar radiation.

  16. NASA combined file postings statistics based on NASA Thesaurus, January 1968 - January 1991

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The NASA Combined File Postings Statistics is published semiannually (January and July). This alphabetical listing of postable subject terms contained in the NASA Thesaurus is used to display the number of postings (documents) indexed by each subject term from 1968 to data. The postings totals per term are separated by announcement or other media into STAR, IAA, NLN, and OTHER columnar entries covering the NASA document collection (1968 to date). Over 595,000 book postings for NALNET Books held by NASA Libraries are included under the NLN column. CSTAR postings as well as some previously unreported series are listed under the 'other' column. The distribution of 18,748,083 postings among the 17,304 Thesaurus terms is tabulated on the last page of Combined File Postings Statistics.

  17. The Pitfalls of Thesaurus Ontologization – the Case of the NCI Thesaurus

    PubMed Central

    Schulz, Stefan; Schober, Daniel; Tudose, Ilinca; Stenzhorn, Holger

    2010-01-01

    Thesauri that are “ontologized” into OWL-DL semantics are highly amenable to modeling errors resulting from falsely interpreting existential restrictions. We investigated the OWL-DL representation of the NCI Thesaurus (NCIT) in order to assess the correctness of existential restrictions. A random sample of 354 axioms using the someValuesFrom operator was taken. According to a rating performed by two domain experts, roughly half of these examples, and in consequence more than 76,000 axioms in the OWL-DL version, make incorrect assertions if interpreted according to description logics semantics. These axioms therefore constitute a huge source for unintended models, rendering most logic-based reasoning unreliable. After identifying typical error patterns we discuss some possible improvements. Our recommendation is to either amend the problematic axioms in the OWL-DL formalization or to consider some less strict representational format. PMID:21347074

  18. NASA thesaurus. Volume 1: Hierarchical Listing

    NASA Technical Reports Server (NTRS)

    1988-01-01

    There are over 17,000 postable terms and nearly 4,000 nonpostable terms approved for use in the NASA scientific and technical information system in the Hierarchical Listing of the NASA Thesaurus. The generic structure is presented for many terms. The broader term and narrower term relationships are shown in an indented fashion that illustrates the generic structure better than the more widely used BT and NT listings. Related terms are generously applied, thus enhancing the usefulness of the Hierarchical Listing. Greater access to the Hierarchical Listing may be achieved with the collateral use of Volume 2 - Access Vocabulary and Volume 3 - Definitions.

  19. NASA thesaurus. Volume 1: Hierarchical listing

    NASA Technical Reports Server (NTRS)

    1985-01-01

    There are 16,835 postable terms and 3,765 nonpostable terms approved for use in the NASA scientific and technical information system in the Hierarchical Listing of the NASA Thesaurus. The generic structure is presented for many terms. The broader term and narrower term relationships are shown in an indented fashion that illustrates the generic structure better than the more widely used BT and NT listings. Related terms are generously applied, thus enhancing the usefulness of the Hierarchical Listing. Greater access to the Hierarchical Listing may be achieved with the collateral use of Volume 2 - Access Vocabulary.

  20. NASA Thesaurus. Volume 1: Hierarchical listing

    NASA Technical Reports Server (NTRS)

    1982-01-01

    There are 16,713 postable terms and 3,716 nonpostable terms approved for use in the NASA scientific and technical information system in the Hierarchical Listing of the NASA Thesaurus. The generic structure is presented for many terms. The broader term and narrower term relationships are shown in an indented fashion that illustrates the generic structure better than the more widely used BT and NT listings. Related terms are generously applied, thus enhancing the usefulness of the Hierarchical Listing. Greater access to the Hierarchical Listing may be achieved with the collateral use of Volume 2 - Access Vocabulary.

  1. Enhancing the MeSH thesaurus to retrieve French online health resources in a quality-controlled gateway.

    PubMed

    Douyère, Magaly; Soualmia, Lina F; Névéol, Aurélie; Rogozan, Alexandrina; Dahamna, Badisse; Leroy, Jean-Philippe; Thirion, Benoît; Darmoni, Stefan J

    2004-12-01

    The amount of health information available on the Internet is considerable. In this context, several health gateways have been developed. Among them, CISMeF (Catalogue and Index of Health Resources in French) was designed to catalogue and index health resources in French. The goal of this article is to describe the various enhancements to the MeSH thesaurus developed by the CISMeF team to adapt this terminology to the broader field of health Internet resources instead of scientific articles for the medline bibliographic database. CISMeF uses two standard tools for organizing information: the MeSH thesaurus and several metadata element sets, in particular the Dublin Core metadata format. The heterogeneity of Internet health resources led the CISMeF team to enhance the MeSH thesaurus with the introduction of two new concepts, respectively, resource types and metaterms. CISMeF resource types are a generalization of the publication types of medline. A resource type describes the nature of the resource and MeSH keyword/qualifier pairs describe the subject of the resource. A metaterm is generally a medical specialty or a biological science, which has semantic links with one or more MeSH keywords, qualifiers and resource types. The CISMeF terminology is exploited for several tasks: resource indexing performed manually, resource categorization performed automatically, visualization and navigation through the concept hierarchies and information retrieval using the Doc'CISMeF search engine. The CISMeF health gateway uses several MeSH thesaurus enhancements to optimize information retrieval, hierarchy navigation and automatic indexing.

  2. Audit of conservative management of chronic low back pain in a secondary care setting--part I: facet joint and sacroiliac joint interventions.

    PubMed

    Chakraverty, Robin; Dias, Richard

    2004-12-01

    The work of a chronic back pain service in secondary care in the West Midlands is reported. The service offers acupuncture, spinal injection procedures, osteopathy and a range of other interventions for patients whose back pain has not responded to conservative management. This section of the report focuses on injection procedures for lumbar facet joint and sacroiliac joint pain, which have been shown to be the cause of chronic low back pain in 16-40% and 13-19% of patients respectively. Diagnosis relies on the use of intra-articular or sensory nerve block injections with local anaesthetic. Possible treatments following diagnosis include intra-articular corticosteroid, radiofrequency denervation (for facet joint pain) or ligament prolotherapy injections (for sacroiliac joint pain). The results of several hospital audits are reported. At six month follow up, 50% of 38 patients undergoing radiofrequency denervation following diagnostic blocks for facet joint pain had improved by more than 50%, compared to 29% of 34 patients treated with intra-articular corticosteroid injection. Sixty three per cent of 19 patients undergoing prolotherapy following diagnostic block injection for sacroiliac joint pain had improved at six months, compared to 33% of 33 who had intra-articular corticosteroid. Both radiofrequency denervation and sacroiliac prolotherapy showed good long-term outcomes at one year.

  3. Anatomy of the pelvic joints--a review.

    PubMed

    Dietrichs, E

    1991-01-01

    In adults, after the os ilium, os ischii and os pubis have joined together by ossification to form the os coxae, there is usually one joint between the hip bones ventrally (the pubic symphysis) and several more complex joints between the hip bones and os sacrum dorsally (sacroiliac, "axial sacroiliac" and accessory sacroiliac joints). These joints carry the weight of the upper part of the body, but they shall also enable pelvic distention during labour. Pathological conditions in these joints are common, and increased knowledge concerning their normal antomy is important for better understanding of these conditions.

  4. A Comparative Evaluation of the Thesaurus of Engineering and Scientific Terms and the DDC Retrieval and Indexing Terminology.

    DTIC Science & Technology

    1977-11-01

    UNLIMITED!IBIR-4J1 * : . C)" A COMPARATIVE EVALUATION OF THE THESAURUS OF, SAENGINEERING AND SCIENTIFIC TERMS AND THE DDC RETRIEVAL AND INDEXING...f cce7,i on For TER1 AND THE DDC RETRIEVAL AND A--" o " INDEXING TERMINOLOGY NTIS - * ByD , 2 _jDitr" : i :/ _ _ . _Av: "jl r " 1 t v Codes...34 . (ii. ABSTRACT A comparative evaluation nas been undertaken or the DDC Retrieval and Indexing Terminology (DRIT) and the Thesaurus of Engineering and

  5. A Thesaurus for Use in a Computer-Aided Abstracting Tool Kit.

    ERIC Educational Resources Information Center

    Craven, Timothy C.

    1993-01-01

    Discusses the use of thesauri in automatic indexing and describes the development of a prototype computerized abstractor's assistant. Topics addressed include TEXNET, a text network management system; the use of TEXNET for abstracting; the structure and use of a thesaurus for abstracting in TEXNET; and weighted terms. (Contains 26 references.)…

  6. Cooperative Engineering as a Joint Action

    ERIC Educational Resources Information Center

    Joffredo-Le Brun, Sophie; Morellato, Mireille; Sensevy, Gérard; Quilio, Serge

    2018-01-01

    This paper describes some elements of a specific kind of design-based research, cooperative engineering. In the first part of the paper, we argue that cooperative engineering can be analyzed through a joint action framework. We first present some conceptual tools that the Joint Action Theory in Didactics proposes in order to understand didactic…

  7. Biomimetic-inspired joining of composite with metal structures: A survey of natural joints and application to single lap joints

    NASA Astrophysics Data System (ADS)

    Avgoulas, Evangelos Ioannis; Sutcliffe, Michael P. F.

    2014-03-01

    Joining composites with metal parts leads, inevitably, to high stress concentrations because of the material property mismatch. Since joining composite to metal is required in many high performance structures, there is a need to develop a new multifunctional approach to meet this challenge. This paper uses the biomimetics approach to help develop solutions to this problem. Nature has found many ingenious ways of joining dissimilar materials and making robust attachments, alleviating potential stress concentrations. A literature survey of natural joint systems has been carried out, identifying and analysing different natural joint methods from a mechanical perspective. A taxonomy table was developed based on the different methods/functions that nature successfully uses to attach dissimilar tissues (materials). This table is used to understand common themes or approaches used in nature for different joint configurations and functionalities. One of the key characteristics that nature uses to joint dissimilar materials is a transitional zone of stiffness in the insertion site. Several biomimetic-inspired metal-to-composite (steel-to-CFRP), adhesively bonded, Single Lap Joints (SLJs) were numerically investigated using a finite element analysis. The proposed solutions offer a transitional zone of stiffness of one joint part to reduce the material stiffness mismatch at the joint. An optimisation procedure was used to identify the variation in material stiffness which minimises potential failure of the joint. It was found that the proposed biomimetic SLJs reduce the asymmetry of the stress distribution along the adhesive area.

  8. Integrating Borrowed Records into a Database: Impact on Thesaurus Development and Retrieval.

    ERIC Educational Resources Information Center

    And Others; Kirtland, Monika

    1980-01-01

    Discusses three approaches to thesaurus and indexing/retrieval language maintenance for combined databases: reindexing, merging, and initial standardization. Two thesauri for a combined database are evaluated in terms of their compatibility, and indexing practices are compared. Tables and figures help illustrate aspects of the comparison. (SW)

  9. Influence of clamp-up force on the strength of bolted composite joints

    NASA Astrophysics Data System (ADS)

    Horn, Walter J.; Schmitt, Ron R.

    1994-03-01

    Composite materials offer the potential for a reduction in the number of individual parts and joints in a structure because large one-piece components can replace multipart assemblies. Nevertheless, there are many situations where composite parts must be joined and often mechanical fasteners provide the only practical method of joining those parts. The long-term strength of mechanically fastened joints of composite members can be directly affected by the clamp-up force of the fastener and thus perhaps by the relaxation of this force due to the viscoelastic character of the composite materials of the joint. Methods for predicting the effect of bolt clamp-up force relaxation on the strength of mechanically fastened joints of thermoplastic composite materials were investigated during the present study. A test program, using two thermoplastic composite materials, was conducted to determine the influence of clamp-up force on joint strength, to measure the relaxation of the joint clamp-up force with time, and to measure the change of joint strength as a function of time.

  10. ASIS Thesaurus of Information Science and Librarianship. ASIS Monograph Series. Second Edition.

    ERIC Educational Resources Information Center

    Milstead, Jessica L., Ed.

    This thesaurus covers the fields of information science and librarianship to a depth that will adequately support indexing, with coverage of related and peripheral fields as warranted by the strength of their relationship to information science and librarianship. Among the related fields are computer science, linguistics, and behavioral and…

  11. Concrete pavement joint deterioration.

    DOT National Transportation Integrated Search

    2015-12-01

    Concrete pavements are an important part of our national infrastructure. In recent years the relatively small number of reported joints deteriorating prematurely in concrete pavements around Indiana has increased. Changes over the past 45 years in IN...

  12. 49 CFR 213.121 - Rail joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... at each joint in Classes 2 through 5 track, and with at least one bolt in Class 1 track. (e) In the... continuous welded rail track prescribed in this part. (g) No rail shall have a bolt hole which is torch cut... 21, 1999. (h) No joint bar shall be reconfigured by torch cutting in Classes 3 through 5 track. ...

  13. Innervation of the Anterior Sacroiliac Joint.

    PubMed

    Cox, Marcus; Ng, Garrett; Mashriqi, Faizullah; Iwanaga, Joe; Alonso, Fernando; Tubbs, Kevin; Loukas, Marios; Oskouian, Rod J; Tubbs, R Shane

    2017-11-01

    Sacroiliac joint pain can be disabling and recalcitrant to medical therapy. The innervation of this joint is poorly understood, especially its anterior aspect. Therefore, the present cadaveric study was performed to better elucidate this anatomy. Twenty-four cadaveric sides underwent dissection of the anterior sacroiliac joint, with special attention given to any branches from regional nerves to this joint. No femoral, obturator, or lumbosacral trunk branches destined to the anterior sacroiliac joint were identified in the 24 sides. In 20 sides, one or two small branches (less than 0.5 mm in diameter) were found to arise from the L4 ventral ramus (10%), the L5 ventral ramus (80%), or simultaneously from both the L4 and L5 ventral rami (10%). The length of the branches ranged from 5 to 31 mm (mean, 14 mm). All these branches arose from the posterior part of the nerves and traveled to the anterior surface of the sacroiliac joint. No statistical significance was found between sides or sexes. An improved knowledge of the innervation of the anterior sacroiliac joint might decrease suffering in patients with chronic sacroiliac joint pain. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Functional anatomy of the temporomandibular joint (I).

    PubMed

    Sava, Anca; Scutariu, Mihaela Monica

    2012-01-01

    Jaw movement is analyzed as the action between two rigid components jointed together in a particular way, the movable mandible against the stabilized cranium. Jaw articulation distinguishes form most other synovial joints of the body by the coincidence of certain characteristic features. Its articular surfaces are not covered by hyaline cartilage as elsewhere. The two jointed components carry teeth the shape, position and occlusion of which having a unique influence on specific positions and movements within the joint. A fibrocartilaginous disc is interposed between upper and lower articular surfaces; this disc compensates for the incongruities in opposing parts and allows sliding, pivoting, and rotating movements between the bony components. These are the reasons for our review of the functional anatomy of the temporomandibular joint.

  15. Thesaurus/Glossary System. User's Guide. Improved Systems for Managing the Control of Paperwork.

    ERIC Educational Resources Information Center

    Hurley, Jeanne S.; And Others

    Intended primarily for the use of NCES (National Center for Education Statistics) staff, this document contains installation-specific information for the Thesaurus/Glossary computer system as installed at the HEW (Health, Education and Welfare) Data Management Center. The first of three sections provides an overview of system objectives,…

  16. Automatic textual annotation of video news based on semantic visual object extraction

    NASA Astrophysics Data System (ADS)

    Boujemaa, Nozha; Fleuret, Francois; Gouet, Valerie; Sahbi, Hichem

    2003-12-01

    In this paper, we present our work for automatic generation of textual metadata based on visual content analysis of video news. We present two methods for semantic object detection and recognition from a cross modal image-text thesaurus. These thesaurus represent a supervised association between models and semantic labels. This paper is concerned with two semantic objects: faces and Tv logos. In the first part, we present our work for efficient face detection and recogniton with automatic name generation. This method allows us also to suggest the textual annotation of shots close-up estimation. On the other hand, we were interested to automatically detect and recognize different Tv logos present on incoming different news from different Tv Channels. This work was done jointly with the French Tv Channel TF1 within the "MediaWorks" project that consists on an hybrid text-image indexing and retrieval plateform for video news.

  17. Basic kinematics and biomechanics of the patellofemoral joint part 2: the patella in total knee arthroplasty.

    PubMed

    Schindler, Oliver S

    2012-02-01

    Patellar and femoral component in total knee arthroplasty are inextricably linked as a functional unit. The configuration of this unit has been a matter of ongoing debate, and the myriad of different patellar and femoral components currently available reflect the lack of consensus with respect to the ideal design. One of the major challenges is to overcome the biomechanical disadvantages of a small contact area through which high contact pressures are transferred, making this mechanical construct the weakest part of the prosthetic knee. Contact areas are highly dependent on the congruency of the patellofemoral joint articulation, and are significantly smaller for dome shaped patellar components compared to those of more anatomic designs. However, when exposed to 3-dimensional movements, the contact areas of the dome shaped patella are significantly greater, indicating enhanced forgiveness regarding patellar malpositioning. Although contact stresses, a function of implant design and surface conformity, can reach levels far beyond the yield strength of UHMWPE, catastrophic failure of resurfaced patellar components, commonly seen in metal backed patellae, fashionable in the 1980s, has rarely been observed since. Although plastic deformation and wear of UHMWPE continue to represent a problem, in the absence of suitable alternatives polyethylene remains the bearing surface of choice. The appreciation of the consequences of the mechanical environment on the behaviour of the patellofemoral joint is of particular importance in the endeavour to develop knee replacement systems which provide satisfactory function together with clinical long-term success.

  18. Water resources thesaurus: A vocabulary for indexing and retrieving the literature of water resources research and development

    USGS Publications Warehouse

    ,

    1980-01-01

    This Water Resources Thesaurus encompasses such broad research areas as the hydrologic cycle, supply of and demand for water, conservation and best use of available supplies of water, methods of increasing supplies, and the economic, legal, social, engineering, recreational, biological, geographical, ecological, and qualitative aspects of water resources. This volume represents a major revision of the previous edition of the Thesaurus, published in 1971. The principal source of terms for this edition has been the indexing used in Selected Water Resources Abstracts (SWRA). Since its inception in 1968, SWRA has indexed tens of thousands of publications. Its indexing terminology has been developed by expert abstracters and researchers, and represents the range of disciplines related to research, development, and management of water resources.

  19. [Tinnitus and temporomandibular joint: State of the art].

    PubMed

    Lina-Granade, G; Truy, E; Ionescu, E; Garnier, P; Thai Van, H

    2016-12-01

    Tinnitus has been described in temporomandibular joint dysfunction for a long time. Yet, other disorders, such as hearing loss, stress, anxiety and depression, play a major role in the pathophysiology of tinnitus. Temporomandibular joint dysfunctions seem to increase the risk of tinnitus in patients with other predisposing factors. Especially somatosensory tinnitus, which is characterized by sound modulations with neck or mandible movements, is frequently associated with temporomandibular joint dysfunction, but it is not pathognomonic of such a disorder. In such cases, functional therapy of the temporomandibular joint should be part of the multidisciplinary rehabilitation of patients with tinnitus. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. 14 CFR Appendix C to Part 151 - Appendix C to Part 151

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Appendix C to Part 151 C Appendix C to Part...) AIRPORTS FEDERAL AID TO AIRPORTS Pt. 151, App. C Appendix C to Part 151 There is set forth below an... Items 1. Maintenance-type work, including: (a) Seal coats. (b) Crack filling. (c) Resealing joints. (d...

  1. Joint hypermobility and headache: the glue that binds the two together--part 2.

    PubMed

    Martin, Vincent T; Neilson, Derek

    2014-09-01

    Past studies have reported that connective tissue disorders (CTDs) are more common in patients with specific types of headache disorders. The objectives of this study are (1) to review and critique the clinical studies reporting an association between joint hypermobility, CTDs and headache and (2) to postulate mechanisms though which CTDs might predispose to headache disorders. PubMed was searched for relevant articles with search terms that included joint hypermobility, Ehlers-Danlos syndrome, Marfan syndrome, and specific headache disorders. A narrative review was performed of these articles as well as those identified from the bibliography of these articles. Case reports and case control studies confirm an association between CTDs and migraine, coat-hanger headaches, carotid arterial dissections, intracranial hypotension, Arnold Chiari malformations-type 1, cervical spine disorders, and temporomandibular joint disorders. Observational cross-sectional studies suggest that the prevalence of CTDs is increased in patients with specific types of headache disorders. It is unknown if the CTDs directly cause these headaches disorders or are associated with them through other mechanisms. © 2014 American Headache Society.

  2. NASA combined file postings statistics based on NASA thesaurus, Jan. 1968 - July 1988

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The NASA Combined File Postings Statistics is published semiannually (January and July). This alphabetical listing of postable subject terms contained in the NASA Thesaurus is used to display the numbers of postings (documents) indexed by each subject term from 1968 to date. The postings total per term are separated by announcement or other media into STAR, IAA, NLN, and OTHER columnar entries covering the NASA document collection (1968 to date). Nearly 594,000 book postings for NALNET Books held by NASA libraries are now included under the NLN column. CSTAR postings as well as some previously unreported series are now listed under the other column. File postings statistics for the Alternate Data Base covering the NASA collection from 1962 through 1967 were published on a one-time basis in September 1975. Subject terms for the Alternate Data Base are derived from the Subject Authority List, reprinted in 1985, which is available on request. The distribution of 16,919,195 postings among the 17,105 Thesaurus terms is tabulated on the last page of Combined File Postings Statistics.

  3. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  4. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  5. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  6. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  7. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  8. The Command and Control of Communications in Joint and Combined Operations

    DTIC Science & Technology

    1994-06-03

    war. The Joint Task Force structure is used as the model for command and control relationships . The first part of the thesis assesses the current...Joint Task Force structure is used as the model for conmand and control relationships . The first part of the thesis assesses the current doctrine and...Message Switch Connectivity . . . . . . . 59 10. C4 Architecture Requirements . . . . . . 81 11. Functional Relationships . . . . . . 84 vi LIST OF

  9. Orthopedic Health: Healthy Joints for a Lifetime / Keep Your Moving Parts Moving

    MedlinePlus

    ... diabetes. The most common form of arthritis is osteoarthritis. It is seen especially among older people and is sometimes called degenerative joint disease. In osteoarthritis, the surface layer of cartilage (the hard but ...

  10. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer constrained... Knee joint femorotibial metal/polymer constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace part...

  11. Design, Static Analysis And Fabrication Of Composite Joints

    NASA Astrophysics Data System (ADS)

    Mathiselvan, G.; Gobinath, R.; Yuvaraja, S.; Raja, T.

    2017-05-01

    The Bonded joints will be having one of the important issues in the composite technology is the repairing of aging in aircraft applications. In these applications and also for joining various composite material parts together, the composite materials fastened together either using adhesives or mechanical fasteners. In this paper, we have carried out design, static analysis of 3-D models and fabrication of the composite joints (bonded, riveted and hybrid). The 3-D model of the composite structure will be fabricated by using the materials such as epoxy resin, glass fibre material and aluminium rivet for preparing the joints. The static analysis was carried out with different joint by using ANSYS software. After fabrication, parametric study was also conducted to compare the performance of the hybrid joint with varying adherent width, adhesive thickness and overlap length. Different joint and its materials tensile test result have compared.

  12. Investigation of premature distress around joints in PCC pavements : parts I & II.

    DOT National Transportation Integrated Search

    2012-10-01

    Some of the Indiana concrete pavements constructed within the last 1020 years have shown signs of premature deterioration, especially in the : areas adjacent to the longitudinal and transverse joints. This deterioration typically manifested itself...

  13. A Study of the Role of Categories in a Thesaurus for Educational Documentation.

    ERIC Educational Resources Information Center

    Foskett, D. J.

    The field of education serves as the basis for this discussion on the use of categories in a thesaurus for information processing and documentation purposes. The author briefly shows how a number of writers concerned with the structure of the field of education, as well as makers of classification schemes, have commented on the value of setting up…

  14. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/composite semi-constrained... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/composite semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace a...

  15. The use of ultrasound in the assessment of the glenoid labrum of the glenohumeral joint. Part II: Examples of labral pathologies

    PubMed Central

    Tarczyńska, Marta

    2012-01-01

    Labral pathologies of the glenohumeral joint are most commonly caused by trauma. The majority of lesions affect the anterior part of labrum, resulting from much higher frequency of anterior shoulder dislocations over posterior ones. Another subgroup of labral lesions, not directly related to joint instability, are SLAP tears. Other findings include degenerative changes of labrum and paralabral cysts. Diagnostic imaging is crucial for making a decision regarding operative treatment. Apart from a standard X-ray examination, the imaging mainly relies on magnetic resonance or computed tomography arthrography. Based on their own experience, the authors propose the use of ultrasound in the assessment of labral tears of the glenohumeral joint. Different signs indicating labral pathology may be discovered and assessed during ultrasound examination. They include permanent displacement of the labrum onto the glenoid, labral instability during dynamic examination, lack of the labrum in the anatomical position, hypoechoic zone at the base of the labrum >2 mm in width, residual or swollen labrum as well as paralabral cyst(s). The most frequent appearance of labral pathology is displacement of the anteroinferior labrum onto the external aspect of the glenoid typically seen after anterior shoulder dislocation. The another most important US feature is labral instability while dynamically examined. The swelling or reduced size of the labrum usually indicates degeneration. This article presents sonographic images of selected labral pathologies. PMID:26672471

  16. The use of ultrasound in the assessment of the glenoid labrum of the glenohumeral joint. Part II: Examples of labral pathologies.

    PubMed

    Krzyżanowski, Wojciech; Tarczyńska, Marta

    2012-09-01

    Labral pathologies of the glenohumeral joint are most commonly caused by trauma. The majority of lesions affect the anterior part of labrum, resulting from much higher frequency of anterior shoulder dislocations over posterior ones. Another subgroup of labral lesions, not directly related to joint instability, are SLAP tears. Other findings include degenerative changes of labrum and paralabral cysts. Diagnostic imaging is crucial for making a decision regarding operative treatment. Apart from a standard X-ray examination, the imaging mainly relies on magnetic resonance or computed tomography arthrography. Based on their own experience, the authors propose the use of ultrasound in the assessment of labral tears of the glenohumeral joint. Different signs indicating labral pathology may be discovered and assessed during ultrasound examination. They include permanent displacement of the labrum onto the glenoid, labral instability during dynamic examination, lack of the labrum in the anatomical position, hypoechoic zone at the base of the labrum >2 mm in width, residual or swollen labrum as well as paralabral cyst(s). The most frequent appearance of labral pathology is displacement of the anteroinferior labrum onto the external aspect of the glenoid typically seen after anterior shoulder dislocation. The another most important US feature is labral instability while dynamically examined. The swelling or reduced size of the labrum usually indicates degeneration. This article presents sonographic images of selected labral pathologies.

  17. Joint hypermobility and headache: understanding the glue that binds the two together--part 1.

    PubMed

    Neilson, Derek; Martin, Vincent T

    2014-09-01

    Heritable connective tissue disorders (HCTD) present with a wide array of findings, including headache. Because of their unusual substrate, headaches in HCTD can derive from both common and uncommon circumstances. Literature review. Ehlers-Danlos hypermobile type can be recognized by multiple joint findings and its tendency to progress to a multisystem chronic pain syndrome. Ehlers-Danlos classic type also manifests joint laxity and similar pain complaints, but is differentiated by its skin laxity and fragility. Ehlers-Danlos vascular type presents the most severe risk due to blood vessel and hollow organ rupture. Marfan syndrome demonstrates skeletal abnormalities, lens dislocations, and aortic root dilation that can result in dissection. In a headache patient, recognizing the presence of an HCTD improves the strategy for diagnosis and management. A brief review of findings related to joints, skin, and arteries may prompt further investigation into the HCTDs. © 2014 American Headache Society.

  18. [Fetal bone and joint disorders].

    PubMed

    Jakobovits, Akos

    2008-12-21

    The article discusses the physiology and pathology of fetal bone and joint development and functions. The bones provide static support for the body. The skull and the bones of spinal column encase the central and part of the peripheral nervous system. The ribs and the sternum shield the heart and the lungs, while the bones of the pelvis protect the intraabdominal organs. Pathological changes of these bony structures may impair the functions of the respective systems or internal organs. Movements of the bones are brought about by muscles. The deriving motions are facilitated by joints. Bony anomalies of the extremities limit their effective functions. Apart from skeletal and joint abnormalities, akinesia may also be caused by neurological, muscular and skin diseases that secondarily affect the functions of bones and joints. Such pathological changes may lead to various degrees of physical disability and even to death. Some of the mentioned anomalies are recognizable in utero by ultrasound. The diagnosis may serve as medical indication for abortion in those instances when the identified abnormality is incompatible with independent life.

  19. Respiratory pattern changes during costovertebral joint movement.

    PubMed

    Shannon, R

    1980-05-01

    Experiments were conducted to determine if costovertebral joint manipulation (CVJM) could influence the respiratory pattern. Phrenic efferent activity (PA) was monitored in dogs that were anesthetized with Dial-urethane, vagotomized, paralyzed, and artificially ventilated. Ribs 6-10 (bilaterally) were cut and separated from ribs 5-11. Branches of thoracic nerves 5-11 were cut, leaving only the joint nerve supply intact. Manual joint movement in an inspiratory or expiratory direction had an inhibitory effect on PA. Sustained displacement of the ribs could inhibit PA for a duration equal to numerous respiratory cycles. CVJM in synchrony with PA resulted in an increased respiratory rate. The inspiratory inhibitory effect of joint receptor stimulation was elicited with manual chest compression in vagotomized spontaneously breathing dogs, but not with artificial lung inflation or deflation. It is concluded that the effect of CVJM on the respiratory pattern is due to stimulation of joint mechanoreceptors, and that they exert their influence in part via the medullary-pontine rhythm generator.

  20. Effect of moisture cycling on truss-plate joint behavior

    Treesearch

    Leslie H. Groom

    1994-01-01

    The structural performance of wood trusses, which are now commonplace in light-frame construction, is dictated in part by the mechanical properties of the truss-plate joints. However, little information exists quantifying the effect of environmental conditions on truss-plate joint properties. The main objective of this paper was to quantify the effect of moisture...

  1. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  2. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemoral polymer/metal semi... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part...

  3. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  4. The Unified Astronomy Thesaurus: Semantic Metadata for Astronomy and Astrophysics

    NASA Astrophysics Data System (ADS)

    Frey, Katie; Accomazzi, Alberto

    2018-05-01

    Several controlled vocabularies have been developed and used by the astronomical community, each designed to serve a specific need and a specific group. The Unified Astronomy Thesaurus (UAT) attempts to provide a highly structured controlled vocabulary that will be relevant and useful across the entire discipline, regardless of content or platform. Because classifying articles and data will be the two major functions of the UAT, we examine the UAT in comparison with the Astronomical Subject Keywords used by major publications and the JWST Science Keywords used by STScI’s Astronomer’s Proposal Tool.

  5. Plating To Reinforce Welded Joints

    NASA Technical Reports Server (NTRS)

    Otousa, J. E.

    1982-01-01

    Electrodeposition used to strengthen welded joints gouged, nicked, or suffered other mechanical damage. Plating cell, typically of acrylic plastic such as poly (Methylmetacrylate), is assembled around part to be plated. Areas not to be plated are masked with plater's tape. Weld area is plated in standard nickel-plating process.

  6. An experimentally based nonlinear viscoelastic model of joint passive moment.

    PubMed

    Esteki, A; Mansour, J M

    1996-04-01

    Previous investigations have not converged on a generally accepted model of the dissipative part of joint passive moment. To provide a basis for developing a model, a series of measurements were performed to characterize the passive moment at the metacarpophalangeal joint of the index finger. Two measurement procedures were used, one in moment relaxation over a range of fixed joint angles and the other at a series of constant joint velocities. Fung's quasi-linear viscoelastic theory motivated the development of the passive moment model. Using this approach, it was not necessary to make restrictive assumptions regarding the viscoelastic behavior of the passive moment. The generality of the formulation allowed specific functions to be chosen based on experimental data rather than finding coefficients which attempted to fit a preselected model of the data. It was shown that a nonlinear viscoelastic model described the passive stiffness. No significant frictional effects were found. Of particular importance was the nonlinear behavior of the dissipative part of the passive moment which was modeled by joint speed raised to a power less than one. This result could explain the differing findings among previous investigations, and may have important implications for control of limb movement.

  7. Advantages of Thesaurus Representation Using the Simple Knowledge Organization System (SKOS) Compared with Proposed Alternatives

    ERIC Educational Resources Information Center

    Pastor-Sanchez, Juan-Antonio; Martinez Mendez, Francisco Javier; Rodriguez-Munoz, Jose Vicente

    2009-01-01

    Introduction: This paper presents an analysis of the Simple Knowledge Organization System (SKOS) compared with other alternatives for thesaurus representation in the Semantic Web. Method: Based on functional and structural changes of thesauri, provides an overview of the current context in which lexical paradigm is abandoned in favour of the…

  8. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  9. The Effectiveness of the Thesaurus Method in Automatic Information Retrieval. Technical Report No. 75-261.

    ERIC Educational Resources Information Center

    Yu, C. T.; Salton, G.

    Formal proofs are given of the effectiveness under well-defined conditions of the thesaurus method in information retrieval. It is shown, in particular, that when certain semantically related terms are added to the information queries originally submitted by the user population, a superior retrieval system is obtained in the sense that for every…

  10. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain

    PubMed Central

    Biswas, Binay Kumar; Dey, Samarjit; Biswas, Saumya; Mohan, Varinder Kumar

    2016-01-01

    Sacroiliac (SI) joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF) neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] – 9/10) with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18th-month follow-up, he is pain free except for mild pain (NRS 2/10) on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment. PMID:28096589

  11. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain.

    PubMed

    Biswas, Binay Kumar; Dey, Samarjit; Biswas, Saumya; Mohan, Varinder Kumar

    2016-01-01

    Sacroiliac (SI) joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF) neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10) with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18 th -month follow-up, he is pain free except for mild pain (NRS 2/10) on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment.

  12. 24 CFR 943.100 - What is the purpose of this part?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... URBAN DEVELOPMENT PUBLIC HOUSING AGENCY CONSORTIA AND JOINT VENTURES General § 943.100 What is the purpose of this part? This part authorizes public housing agencies (PHAs) to form consortia, joint ventures, affiliates, subsidiaries, partnerships, and other business arrangements under section 13 of the...

  13. Medicare Program; Comprehensive Care for Joint Replacement Payment Model for Acute Care Hospitals Furnishing Lower Extremity Joint Replacement Services. Final rule.

    PubMed

    2015-11-24

    This final rule implements a new Medicare Part A and B payment model under section 1115A of the Social Security Act, called the Comprehensive Care for Joint Replacement (CJR) model, in which acute care hospitals in certain selected geographic areas will receive retrospective bundled payments for episodes of care for lower extremity joint replacement (LEJR) or reattachment of a lower extremity. All related care within 90 days of hospital discharge from the joint replacement procedure will be included in the episode of care. We believe this model will further our goals in improving the efficiency and quality of care for Medicare beneficiaries with these common medical procedures.

  14. Extended tensile testing of welded joints of polyethylene pipes

    NASA Astrophysics Data System (ADS)

    Danzanova, E. V.; Gerasimov, A. I.; Botvin, G. V.

    2017-12-01

    The paper introduces the results of testing joints welded in the open air at low climatic temperatures (below minus 15 °C) without heated facilities. Extended tensile testing in an active medium reveals that the same quality standard of welded joints is reached when welded parts are preheated when welding is performed under conditions of low climatic temperatures, and when they are welded at permissible temperatures.

  15. Biomechanical design of escalading lower limb exoskeleton with novel linkage joints.

    PubMed

    Zhang, Guoan; Liu, Gangfeng; Ma, Sun; Wang, Tianshuo; Zhao, Jie; Zhu, Yanhe

    2017-07-20

    In this paper, an obstacle-surmounting-enabled lower limb exoskeleton with novel linkage joints that perfectly mimicked human motions was proposed. Currently, most lower exoskeletons that use linear actuators have a direct connection between the wearer and the controlled part. Compared to the existing joints, the novel linkage joint not only fitted better into compact chasis, but also provided greater torque when the joint was at a large bend angle. As a result, it extended the angle range of joint peak torque output. With any given power, torque was prioritized over rotational speed, because instead of rotational speed, sufficiency of torque is the premise for most joint actions. With insufficient torque, the exoskeleton will be a burden instead of enhancement to its wearer. With optimized distribution of torque among the joints, the novel linkage method may contribute to easier exoskeleton movements.

  16. Solder Creep-Fatigue Interactions with Flexible Leaded Part

    NASA Technical Reports Server (NTRS)

    Ross, R. G., Jr.; Wen, L. C.

    1994-01-01

    In most electronic packaging applications it is not a single high stress event that breaks a component solder joint; rather it is repeated or prolonged load applications that result in fatigue or creep failure of the solder. The principal strain in solder joints is caused by differential expansion between the part and its mounting environment due to hanges in temperature (thermal cycles) and/or due to temperature gradients between the part and the board.

  17. Regular Mechanical Transformation of Rotations Into Translations: Part 2. Kinematic Synthesis of the Elements of High Kinematic Joints, Realizing the Process of Motions Transformation

    NASA Astrophysics Data System (ADS)

    Abadjieva, Emilia; Abadjiev, Valentin

    2017-09-01

    This work is developed on the basis of the illustrated main parts of the kinematic theory (theory of gearing) of the spatial rack drives in Part 1 of this study. The applied theoretical approach to their synthesis, based on the T. Olivier's second principle is defined. A study of the geometric nature of the surface of action (mesh region, respectively) of these class transmissions is shown. Research software programs for synthesis and visualization of these transmissions and their specific elements are elaborated, on the basis of the given algorithms to the synthesis of the elements of high kinematic joints (active tooth surfaces), with which the movable links of the studied gear systems are equipped.

  18. Functional joint regeneration is achieved using reintegration mechanism in Xenopus laevis

    PubMed Central

    Yamada, Shigehito

    2016-01-01

    Abstract A functional joint requires integration of multiple tissues: the apposing skeletal elements should form an interlocking structure, and muscles should insert into skeletal tissues via tendons across the joint. Whereas newts can regenerate functional joints after amputation, Xenopus laevis regenerates a cartilaginous rod without joints, a “spike.” Previously we reported that the reintegration mechanism between the remaining and regenerated tissues has a significant effect on regenerating joint morphogenesis during elbow joint regeneration in newt. Based on this insight into the importance of reintegration, we amputated frogs’ limbs at the elbow joint and found that frogs could regenerate a functional elbow joint between the remaining tissues and regenerated spike. During regeneration, the regenerating cartilage was partially connected to the remaining articular cartilage to reform the interlocking structure of the elbow joint at the proximal end of the spike. Furthermore, the muscles of the remaining part inserted into the regenerated spike cartilage via tendons. This study might open up an avenue for analyzing molecular and cellular mechanisms of joint regeneration using Xenopus. PMID:27499877

  19. [Imaging of the elbow joint with focus MRI. Part 2: muscles, nerves and synovial membranes].

    PubMed

    Rehm, J; Zeifang, F; Weber, M-A

    2014-03-01

    This review article discusses the magnetic resonance imaging (MRI) features and pathological changes of muscles, nerves and the synovial lining of the elbow joint. Typical imaging findings are illustrated and discussed. In addition, the cross-sectional anatomy and anatomical variants, such as accessory muscles and plicae are discussed. Injuries of the muscles surrounding the elbow joint, as well as chronic irritation are particularly common in athletes. Morphological changes in MRI, for example tennis or golfer's elbow are typical and often groundbreaking. By adapting the examination sequences, imaging planes and slices, complete and incomplete tendon ruptures can be reliably diagnosed. Although the clinical and electrophysiological examinations form the basis for the diagnosis of peripheral neuropathies, MRI provides useful additional information about the precise localization due to its high resolution and good soft tissue contrast and helps to rule out differential diagnoses. Synovial diseases, such as inflammatory arthritis, proliferative diseases and also impinging plicae must be considered in the MRI diagnostics of the elbow joint.

  20. 17 CFR 300.105 - Joint accounts.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Joint accounts. 300.105 Section 300.105 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) Schedule A to Part 285 RULES OF THE SECURITIES INVESTOR PROTECTION CORPORATION Accounts of âseparateâ...

  1. 14 CFR 296.4 - Joint loading.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS INDIRECT AIR TRANSPORTATION OF PROPERTY General § 296.4 Joint loading. Nothing in this part shall... transportation as one shipment, under an agreement between two or more indirect air carriers or foreign indirect...

  2. The postnatal development of the temporal part of the human temporomandibular joint. A quantitative study on skulls.

    PubMed

    Dibbets, J M; Dijkman, G E

    1997-12-01

    The morphology of the temporal part of the human temporomandibular joint (TMJ) changes drastically during postnatal development. The glenoid fossa will acquire its characteristic S shape and a tubercle will develop. The combined results of the literature and of this study allow a reconstruction of the actual growth processes. The roof of the glenoid fossa appears to enlarge forward by remodeling while sagittal and vertical growth is mainly achieved by deposition at the top of the tubercle. These latter changes result in a steeper slope of the eminence and take place in 3 phases, parallelling the eruption of the first incisors, the permanent first molars and the permanent second molars. While the zygomatic arch thickens by deposition at all surfaces, it also remodels downward relative to the external meatus. As a result, the neonate anulus occupies a lower position relative to this arch than does the adult meatus.

  3. Automatic Concept-Based Query Expansion Using Term Relational Pathways Built from a Collection-Specific Association Thesaurus

    ERIC Educational Resources Information Center

    Lyall-Wilson, Jennifer Rae

    2013-01-01

    The dissertation research explores an approach to automatic concept-based query expansion to improve search engine performance. It uses a network-based approach for identifying the concept represented by the user's query and is founded on the idea that a collection-specific association thesaurus can be used to create a reasonable representation of…

  4. The Contemporary Thesaurus of Social Science Terms and Synonyms: A Guide for Natural Language Computer Searching.

    ERIC Educational Resources Information Center

    Knapp, Sara D., Comp.

    This book is designed primarily to help users find meaningful words for natural language, or free-text, computer searching of bibliographic and textual databases in the social and behavioral sciences. Additionally, it covers many socially relevant and technical topics not covered by the usual literary thesaurus, therefore it may also be useful for…

  5. Influence of the Gap Width on the Geometry of the Welded Joint in Hybrid Laser-Arc Welding

    NASA Astrophysics Data System (ADS)

    Turichin, G.; Tsibulskiy, I.; Kuznetsov, M.; Akhmetov, A.; Mildebrath, M.; Hassel, T.

    The aim of this research was the experimental investigation of the influence of the gap width and speed of the welding wire on the changes of the geometry in the welded joint in the hybrid laser-arc welding of shipbuilding steel RS E36. The research was divided into three parts. First, in order to understand the influence of the gap width on the welded joint geometry, experimental research was done using continuous wave fiber laser IPG YLS-15000 with arc rectifier VDU-1500DC. The second part involved study of the geometry of the welded joint and hardness test results. Three macrosections from each welded joint were obtained. Influence of the gap width and welding wire speed on the welded joint geometry was researched in the three lines: in the right side of the plates, middle welded joint and in the root welded joint.

  6. Anatomical evidence for the anterior plate fixation of sacroiliac joint.

    PubMed

    Bai, Zhibiao; Gao, Shichang; Liu, Jia; Liang, Anlin; Yu, Weihua

    2018-01-01

    The iatrogenic injuries to the lumbar nerves during the fixation the sacroiliac (SI) joint fractures with anterior plates were often reported. No specific method had been reported to avoid it. This study was done to find a safer way of placing the anterior plates and screws for treating the sacroiliac (SI) joint fracture and/or dislocation. The research was performed using 8 male and 7 female normal corpse pelvic specimens preserved by 10% formalin solution. Try by measuring the horizontal distance from L4, L5 nerve roots to the sacroiliac joint and perpendicular distance from L4, L5 nerve roots to the ala sacralis, the length of L4, L5 nerve roots from intervertebral foramen to the edge of true pelvis, the diameter of L4, L5 nerve roots. The angles between the sacroiliac joint and sagittal plane were measured on the CT images. The horizontal distance between the lateral side of the anterior branches of L4, L5 nerve roots and the sacroiliac joint decreased gradually from the top to the bottom. The widest distances for L4,5 were 2.1 cm (range, 1.74-2.40) and 2.7 cm (range, 2.34-3.02 cm), respectively. The smallest distances for L4, 5 were 1.2 cm (range, 0.82-1.48 cm) and 1.5 cm (range, 1.08-1.74 cm), respectively. On CT images, the angle between the sacroiliac joint and sagittal plane was about 30°. If we use two anterior plates to fix the sacroiliac joint, It is recommended to place one plate on the superior one third part of the joint, with exposing medially no more than 2.5 cm and the other in the middle one third part of the joint, with elevating periosteum medially no more than 1.5 cm. The screws in the sacrum are advised to incline medially about 30° directing to the true pelvis. Copyright © 2017. Published by Elsevier B.V.

  7. Peter Mark Roget: physician, scientist, systematist; his thesaurus and his impact on 19th-century neuroscience.

    PubMed

    Kruger, Lawrence; Finger, Stanley

    2013-01-01

    Peter Mark Roget (1779-1869) is best known for his Thesaurus, a project completed late in his long life. He trained as a physician, practiced medicine, and was interested in many branches of science. Much of his life was dedicated to the systematization of knowledge and identifying relationships. Although not an experimentalist in the modern sense of the word, he contributed to "neuroscience" in journal and encyclopaedia articles, as well as in books and lectures. He wrote extensively on comparative physiology, sensory systems, phrenology, optics, and various disorders affecting the nervous system. He viewed his two-volume Bridgewater Treatise of 1834 as his most significant achievement, turning to physiology and comparative anatomy to argue that God's existence can be seen in how living forms and their components are designed. Roget was active in many scholarly organizations, most notably the Royal Society of London, where he served for more than two decades as its secretary before "retiring" to pursue his Thesaurus. © 2013 Elsevier B.V. All rights reserved.

  8. Thermally Conductive Metal-Tube/Carbon-Composite Joints

    NASA Technical Reports Server (NTRS)

    Copeland, Robert J.

    2004-01-01

    An improved method of fabricating joints between metal and carbon-fiber-based composite materials in lightweight radiators and heat sinks has been devised. Carbon-fiber-based composite materials have been used in such heat-transfer devices because they offer a combination of high thermal conductivity and low mass density. Metal tubes are typically used to carry heat-transfer fluids to and from such heat-transfer devices. The present fabrication method helps to ensure that the joints between the metal tubes and the composite-material parts in such heat-transfer devices have both (1) the relatively high thermal conductances needed for efficient transfer of heat and (2) the flexibility needed to accommodate differences among thermal expansions of dissimilar materials in operation over wide temperature ranges. Techniques used previously to join metal tubes with carbon-fiber-based composite parts have included press fitting and bonding with epoxy. Both of these prior techniques have been found to yield joints characterized by relatively high thermal resistances. The present method involves the use of a solder (63 percent Sn, 37 percent Pb) to form a highly thermally conductive joint between a metal tube and a carbon-fiber-based composite structure. Ordinarily, the large differences among the coefficients of thermal expansion of the metal tube, solder, and carbon-fiber-based composite would cause the solder to pull away from the composite upon post-fabrication cooldown from the molten state. In the present method, the structure of the solder is modified (see figure) to enable it to deform readily to accommodate the differential thermal expansion.

  9. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  10. How weak values emerge in joint measurements on cloned quantum systems.

    PubMed

    Hofmann, Holger F

    2012-07-13

    A statistical analysis of optimal universal cloning shows that it is possible to identify an ideal (but nonpositive) copying process that faithfully maps all properties of the original Hilbert space onto two separate quantum systems, resulting in perfect correlations for all observables. The joint probabilities for noncommuting measurements on separate clones then correspond to the real parts of the complex joint probabilities observed in weak measurements on a single system, where the measurements on the two clones replace the corresponding sequence of weak measurement and postselection. The imaginary parts of weak measurement statics can be obtained by replacing the cloning process with a partial swap operation. A controlled-swap operation combines both processes, making the complete weak measurement statistics accessible as a well-defined contribution to the joint probabilities of fully resolved projective measurements on the two output systems.

  11. 25 CFR 217.4 - Referral of questions by the joint managers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Referral of questions by the joint managers. 217.4... DISTRIBUTION CORP. § 217.4 Referral of questions by the joint managers. The business committee and the board of... manager at the address furnished in accordance with § 217.3 of this part. Copies of all such referrals...

  12. Superior Recess Access of the Lumbar Facet Joint.

    PubMed

    Demir-Deviren, Sibel; Singh, Sukhminder; Hanelin, Joshua

    2017-04-01

    Descriptive approach to accessing the lumbar facet joint by superior recess. This study is aimed to describe an approach to accessing the lumbar facet joint through targeting the superior recess during lumbar facet joint injections. Lumbar facet joint injections are routinely performed for both the diagnosis and treatment of chronic low back pain. Previous studies either did not specify which part of the joint to target, or recommended targeting the inferior aspect of the joint to access the inferior recess. One study did mention the superior recess as an alternative to injecting the inferior recess, but none has focused on description of the technique. This is the first time this technique has been described. The records and fluoroscopic images were reviewed for all patients over a period of 9 months (January-September 2012) using the proposed technique. This resulted in a total of 48 patients; 15 men, 29 women, and a total of 117 facet joint intra-articular injections. Among these 48 patients, injections were repeated in total of 4 cases. The average time of injections among 4 repeat cases was 121 days. The success of the procedure was confirmed with an arthrogram demonstrating contrast flowing from the superior recess inferiorly through the joint space. Successful access of the lumbar facet joint through puncture of the superior recess was seen in 114 cases, with 3 unsuccessful attempts to enter facet joints due to osteophytes at involved levels. There were no complications observed during the procedure. We find this approach to be highly successful, safe, and well tolerated by the patient and recommend it as a technique for access of the lumbar facet joint in those patients in whom direct puncture of the inferior recess is difficult.

  13. Analysis of the stress-strain state in single overlap joints using piezo-ceramic actuators

    NASA Astrophysics Data System (ADS)

    Pǎltânea, Veronica; Pǎltânea, Gheorghe; Popovici, Dorina; Jiga, Gabriel; Papanicolaou, George

    2014-05-01

    In this paper is presented a 2D approach to finite element modeling and an analytical calculus of a single lap bonded joint. As adherent material were selected a sheet of wood, aluminum and titanium. For adhesive part were selected Bison Super Wood D3 in case of the wood single lap joint and an epoxy resin type DGEBA-TETA for gluing together aluminum and titanium parts. In the article is described a combined method, which consists in the placement of the piezoelectric actuator inside of the adhesive part, in order to determine the tensile stress in the overlap joint. A comparison between the analytical and numerical results has been achieved through a multiphysics modeling - electrical and mechanical coupled problem. The technique used to calculate the mechanical parameters (First Principal Stress, displacements) was the three-point bending test, where different forces were applied in the mid-span of the structure, in order to maintain a constant displacement rate. The length of the overlap joint was modified from 20 to 50 mm.

  14. The use of ultrasound in the assessment of the glenoid labrum of the glenohumeral joint. Part I: Ultrasound anatomy and examination technique

    PubMed Central

    2012-01-01

    The glenohumeral joint is a spherical articulation with a remarkable range of motion in several planes and decreased stability. The maintenance of joint stability is influenced by the functioning of specific muscle groups in the shoulder region, a complex system of ligaments reinforcing the joint capsule, and the labrum which augments the glenoid fossa. Lesions of the aforementioned structures require accurate diagnosis prior to a decision for operative treatment. Ultrasound is one of the imaging methods that has been widely used in the assessment of various shoulder pathologies. In the author opinion, this imaging modality may also be applied for the evaluation of labral tears. Being attached along the glenoid rim, the labrum forms a collar deepening the glenoid fossa thus increasing area of its contact with the head of the humerus. To better describe the location of lesions, the glenoid labrum is usually divided into certain zones. Most of them may be visualized sonographically. The US examination of the posterior labrum can be performed during evaluation of the infraspinatus and teres minor muscles. The anterior labrum along with capsulolabral complex is seen at the glenoid edge under the subscapularis tendon. Sonographic examination of the inferior labrum is best performed using axillar approach. The superior labrum is only partially available for US examination. A crucial part of the sonographic assessment of the labrum is the dynamic examination during rotation of the upper extremity. The paper presents normal sonographic anatomy of the glenoid labrum and technique of the examination. PMID:26673515

  15. Prosthetic elbow joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce C. (Inventor)

    1994-01-01

    An artificial, manually positionable elbow joint for use in an upper extremity, above-elbow, prosthetic is described. The prosthesis provides a locking feature that is easily controlled by the wearer. The instant elbow joint is very strong and durable enough to withstand the repeated heavy loadings encountered by a wearer who works in an industrial, construction, farming, or similar environment. The elbow joint of the present invention comprises a turntable, a frame, a forearm, and a locking assembly. The frame generally includes a housing for the locking assembly and two protruding ears. The forearm includes an elongated beam having a cup-shaped cylindrical member at one end and a locking wheel having a plurality of holes along a circular arc on its other end with a central bore for pivotal attachment to the protruding ears of the frame. The locking assembly includes a collar having a central opening with a plurality of internal grooves, a plurality of internal cam members each having a chamfered surface at one end and a V-shaped slot at its other end; an elongated locking pin having a crown wheel with cam surfaces and locking lugs secured thereto; two coiled compression springs; and a flexible filament attached to one end of the elongated locking pin and extending from the locking assembly for extending and retracting the locking pin into the holes in the locking wheel to permit selective adjustment of the forearm relative to the frame. In use, the turntable is affixed to the upper arm part of the prosthetic in the conventional manner, and the cup-shaped cylindrical member on one end of the forearm is affixed to the forearm piece of the prosthetic in the conventional manner. The elbow joint is easily adjusted and locked between maximum flex and extended positions.

  16. Anatomy of the collateral ligaments of the feline elbow joint: functional implications.

    PubMed

    Engelke, E; Pfarrer, C; Waibl, H

    2011-04-01

    Cats show a higher capability to supinate their forearms than dogs. This suggests a special arrangement of the collateral ligaments of the feline elbow joint. Therefore, the course of the ligaments was examined in 13 adult cats. The size of the ligaments was measured, and effects of passive joint movements were studied. Ligaments of five additional cats were examined histologically. The lateral collateral ligament (LCL) had a superficial and deep part, both originating from the humerus. The free humeral portion of the LCL was short and contained fibrous cartilage. Fibre bundles of the deep part inserted into the annular ligament, while the remaining deep fibres and the superficial part inserted with a long antebrachial portion on the radius. The medial collateral ligament (MCL) originated from the humeral epicondyle and divided into cranial and caudal parts. The caudal part inserted medioproximally on the ulna, while the cranial part attached primarily with a long thin part to the caudal aspect of the radius. During supination, the MCL loosened thus allowing medial widening of the joint space, up to 2 mm. A specific feature of the feline elbow is the long thin part of the MCL. Its course through a special furrow distal to the medial coronoid causes the tightening of the feline MCL during pronation. Apart from that, the feline collateral ligaments combine the features of both human and canine cubital anatomy. This explains the range of supination in cats, which is intermediate between humans and dogs. © 2010 Blackwell Verlag GmbH.

  17. Thrust Force Analysis of Tripod Constant Velocity Joint Using Multibody Model

    NASA Astrophysics Data System (ADS)

    Sugiura, Hideki; Matsunaga, Tsugiharu; Mizutani, Yoshiteru; Ando, Yosei; Kashiwagi, Isashi

    A tripod constant velocity joint is used in the driveshaft of front wheel drive vehicles. Thrust force generated by this joint causes lateral vibration in these vehicles. To analyze the thrust force, a detailed model is constructed based on a multibody dynamics approach. This model includes all principal parts of the joint defined as rigid bodies and all force elements of contact and friction acting among these parts. This model utilizes a new contact modeling method of needle roller bearings for more precise and faster computation. By comparing computational and experimental results, the appropriateness of this model is verified and the principal factors inducing the second and third rotating order components of the thrust force are clarified. This paper also describes the influence of skewed needle rollers on the thrust force and evaluates the contribution of friction forces at each contact region to the thrust force.

  18. Effect of static and dynamic muscle stretching as part of warm up procedures on knee joint proprioception and strength.

    PubMed

    Walsh, Gregory S

    2017-10-01

    The importance of warm up procedures prior to athletic performance is well established. A common component of such procedures is muscle stretching. There is conflicting evidence regarding the effect of static stretching (SS) as part of warm up procedures on knee joint position sense (KJPS) and the effect of dynamic stretching (DS) on KJPS is currently unknown. The aim of this study was to determine the effect of dynamic and static stretching as part warm up procedures on KJPS and knee extension and flexion strength. This study had a randomised cross-over design and ten healthy adults (20±1years) attended 3 visits during which baseline KJPS, at target angles of 20° and 45°, and knee extension and flexion strength tests were followed by 15min of cycling and either a rest period (CON), SS, or DS and repeat KJPS and strength tests. All participants performed all conditions, one condition per visit. There were warm up×stretching type interactions for KJPS at 20° (p=0.024) and 45° (p=0.018), and knee flexion (p=0.002) and extension (p<0.001) strength. The SS and DS improved KJPS but CON condition did not and SS decreased strength. No change in strength was present for DS or CON. Both SS and DS improve KJPS as part of pre-exercise warm up procedures. However, the negative impact of SS on muscle strength limits the utility of SS before athletic performance. If stretching is to be performed as part of a warm up, DS should be favoured over SS. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Review on failure prediction techniques of composite single lap joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ab Ghani, A.F., E-mail: ahmadfuad@utem.edu.my; Rivai, Ahmad, E-mail: ahmadrivai@utem.edu.my

    2016-03-29

    Adhesive bonding is the most appropriate joining method in construction of composite structures. The use of reliable design and prediction technique will produce better performance of bonded joints. Several papers from recent papers and journals have been reviewed and synthesized to understand the current state of the art in this area. It is done by studying the most relevant analytical solutions for composite adherends with start of reviewing the most fundamental ones involving beam/plate theory. It is then extended to review single lap joint non linearity and failure prediction and finally on the failure prediction on composite single lap joint.more » The review also encompasses the finite element modelling part as tool to predict the elastic response of composite single lap joint and failure prediction numerically.« less

  20. Degenerative joint disease: multiple joint involvement in young and mature dogs.

    PubMed

    Olsewski, J M; Lust, G; Rendano, V T; Summers, B A

    1983-07-01

    Radiologic, pathologic, and ancillary methods were used to determine the occurrence of degenerative joint disease involving multiple joints of immature and adult dogs. Animals were selected for the development of hip joint dysplasia and chronic degenerative joint disease. Of disease-prone dogs, 82% (45 of 55 dogs) had radiologic changes, indicative of hip dysplasia, by 1 year of age. At necropsy, more abnormal joints were identified than by radiographic examination. Among 92 dogs between 3 to 11 months of age that had joint abnormalities, 71% had hip joint involvement; 38%, shoulder joint involvement; 22%, stifle joint involvement; and 40% had multiple joint involvement. Polyarthritis was asymptomatic and unexpected. Radiographic examination of older dogs also revealed evidence of degenerative joint disease in many joints. Multiple joint involvement was substantiated at necropsy of young and mature dogs. A similar pattern of polyarticular osteoarthritis was revealed in a survey (computer search) of necropsy reports from medical case records of 100 adult and elderly dogs. Usually, the joint disease was an incidental observation, unrelated to the clinical disease or to the cause of death. The frequent occurrence of degenerative changes in several joints of dogs aged 6 months to 17 years indicated that osteoarthritis may be progressive in these joints and raises the possibility that systemic factors are involved in the disease process.

  1. Results and Analysis from Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer

    2010-01-01

    A space suit's mobility is critical to an astronaut's ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. Mobility can be broken down into two parts: range of motion (ROM) and torque. These two measurements describe how the suit moves and how much force it takes to move. Two methods were chosen to define mobility requirements for the Constellation Space Suit Element (CSSE). One method focuses on range of motion and the second method centers on joint torque. A joint torque test was conducted to determine a baseline for current advanced space suit joint torques. This test utilized the following space suits: Extravehicular Mobility Unit (EMU), Advanced Crew Escape Suit (ACES), I-Suit, D-Suit, Enhanced Mobility (EM)- ACES, and Mark III (MK-III). Data was collected data from 16 different joint movements of each suit. The results were then reviewed and CSSE joint torque requirement values were selected. The focus of this paper is to discuss trends observed during data analysis.

  2. Characterization of Nitinol Laser-Weld Joints by Nondestructive Testing

    NASA Astrophysics Data System (ADS)

    Wohlschlögel, Markus; Gläßel, Gunter; Sanchez, Daniela; Schüßler, Andreas; Dillenz, Alexander; Saal, David; Mayr, Peter

    2015-12-01

    Joining technology is an integral part of today's Nitinol medical device manufacturing. Besides crimping and riveting, laser welding is often applied to join components made from Nitinol to Nitinol, as well as Nitinol components to dissimilar materials. Other Nitinol joining techniques include adhesive bonding, soldering, and brazing. Typically, the performance of joints is assessed by destructive mechanical testing, on a process validation base. In this study, a nondestructive testing method—photothermal radiometry—is applied to characterize small Nitinol laser-weld joints used to connect two wire ends via a sleeve. Two different wire diameters are investigated. Effective joint connection cross sections are visualized using metallography techniques. Results of the nondestructive testing are correlated to data from destructive torsion testing, where the maximum torque at fracture is evaluated for the same joints and criteria for the differentiation of good and poor laser-welding quality by nondestructive testing are established.

  3. Rubber Hand Illusion Affects Joint Angle Perception

    PubMed Central

    Butz, Martin V.; Kutter, Esther F.; Lorenz, Corinna

    2014-01-01

    The Rubber Hand Illusion (RHI) is a well-established experimental paradigm. It has been shown that the RHI can affect hand location estimates, arm and hand motion towards goals, the subjective visual appearance of the own hand, and the feeling of body ownership. Several studies also indicate that the peri-hand space is partially remapped around the rubber hand. Nonetheless, the question remains if and to what extent the RHI can affect the perception of other body parts. In this study we ask if the RHI can alter the perception of the elbow joint. Participants had to adjust an angular representation on a screen according to their proprioceptive perception of their own elbow joint angle. The results show that the RHI does indeed alter the elbow joint estimation, increasing the agreement with the position and orientation of the artificial hand. Thus, the results show that the brain does not only adjust the perception of the hand in body-relative space, but it also modifies the perception of other body parts. In conclusion, we propose that the brain continuously strives to maintain a consistent internal body image and that this image can be influenced by the available sensory information sources, which are mediated and mapped onto each other by means of a postural, kinematic body model. PMID:24671172

  4. Spacesuit mobility joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1978-01-01

    Joints for use in interconnecting adjacent segments of an hermetically sealed spacesuit which have low torques, low leakage and a high degree of reliability are described. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics. Linkages which restrain the joint from longitudinal distension and a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli are featured. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  5. The association of sacroiliac joint bridging with other enthesopathies in the human body.

    PubMed

    Dar, Gali; Peleg, Smadar; Masharawi, Youssef; Steinberg, Nili; Rothschild, Bruce M; Hershkovitz, Israel

    2007-05-01

    A descriptive study of the association between sacroiliac joint (extra-articular) bridging and other enthesopathies. To examine the relationship between sacroiliac joint bridging with other entheseal reaction sites in the skeleton, and its prognostic value in spinal diseases. Sacroiliac joint bridging is considered a hallmark of spinal diseases (e.g., ankylosing spondylitis). Nevertheless, its association with other enthesopathies has never been quantified and analyzed. A total of 289 human male skeletons with sacroiliac joint bridging and 127 without (of similar demographic structure) were evaluated for the presence of entheseal ossification, cartilaginous calcification, and other axial skeleton joint fusion (a total of 18 anatomic sites). The presence of diffuse idiopathic skeletal hyperostosis and spondyloarthropathy was also recorded. Sacroiliac joint bridging was strongly associated with entheseal reactions in other parts of the body. Of the sacroiliac joint bridging group, 24.91% had diffuse idiopathic skeletal hyperostosis, and 8.05% had spondyloarthropathy. The presence of sacroiliac joint bridging indicates an intensive general entheseal process in the skeleton.

  6. Simulation and Experiment Research on Fatigue Life of High Pressure Air Pipeline Joint

    NASA Astrophysics Data System (ADS)

    Shang, Jin; Xie, Jianghui; Yu, Jian; Zhang, Deman

    2017-12-01

    High pressure air pipeline joint is important part of high pressure air system, whose reliability is related to the safety and stability of the system. This thesis developed a new type-high pressure air pipeline joint, carried out dynamics research on CB316-1995 and new type-high pressure air pipeline joint with finite element method, deeply analysed the join forms of different design schemes and effect of materials on stress, tightening torque and fatigue life of joint. Research team set up vibration/pulse test bench, carried out joint fatigue life contrast test. The result shows: the maximum stress of the joint is inverted in the inner side of the outer sleeve nut, which is consistent with the failure mode of the crack on the outer sleeve nut in practice. Simulation and experiment of fatigue life and tightening torque of new type-high pressure air pipeline joint are better than CB316-1995 joint.

  7. Numerical simulation of artificial hip joint motion based on human age factor

    NASA Astrophysics Data System (ADS)

    Ramdhani, Safarudin; Saputra, Eko; Jamari, J.

    2018-05-01

    Artificial hip joint is a prosthesis (synthetic body part) which usually consists of two or more components. Replacement of the hip joint due to the occurrence of arthritis, ordinarily patients aged or older. Numerical simulation models are used to observe the range of motion in the artificial hip joint, the range of motion of joints used as the basis of human age. Finite- element analysis (FEA) is used to calculate stress von mises in motion and observes a probability of prosthetic impingement. FEA uses a three-dimensional nonlinear model and considers the position variation of acetabular liner cups. The result of numerical simulation shows that FEA method can be used to analyze the performance calculation of the artificial hip joint at this time more accurate than conventional method.

  8. Preliminary Design and Analysis of an In-plane PRSEUS Joint

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Poplawski, Steven

    2013-01-01

    As part of the National Aeronautics and Space Administration's (NASA's) Environmentally Responsible Aviation (ERA) program, the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) has been designed, developed and tested. However, PRSEUS development efforts to date have only addressed joints required to transfer bending moments between PRSEUS panels. Development of in-plane joints for the PRSEUS concept is necessary to facilitate in-plane transfer of load from PRSEUS panels to an adjacent structure, such as from a wing panel into a fuselage. This paper presents preliminary design and analysis of an in-plane PRSEUS joint for connecting PRSEUS panels at the termination of the rod-stiffened stringers. Design requirements are provided, the PRSEUS blade joint concept is presented, and preliminary design changes and analyses are carried out to examine the feasibility of the proposed in-plane PRSEUS blade joint. The study conducted herein focuses mainly on the PRSEUS structure on one side of the joint. In particular, the design requirements for the rod shear stress and bolt bearing stress are examined. A PRSEUS blade joint design was developed that demonstrates the feasibility of this in-plane PRSEUS joint concept to terminate the rod-stiffened stringers. The presented design only demonstrates feasibility, therefore, some areas of refinement are presented that would lead to a more optimum and realistic design.

  9. Joint Technical Architecture for Robotic Systems (JTARS)-Final Report

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T.; Holloway, Sidney E., III

    2006-01-01

    This document represents the final report for the Joint Technical Architecture for Robotic Systems (JTARS) project, funded by the Office of Exploration as part of the Intramural Call for Proposals of 2005. The project was prematurely terminated, without review, as part of an agency-wide realignment towards the development of a Crew Exploration Vehicle (CEV) and meeting the near-term goals of lunar exploration.

  10. Coracoclavicular joint: osteologic study of 1020 human clavicles

    PubMed Central

    Gumina, S; Salvatore, M; De Santis, P; Orsina, L; Postacchini, F

    2002-01-01

    We examined 1020 dry clavicles from cadavers of Italian origin to determine the prevalence of the coracoclavicular joint (ccj), a diarthrotic synovial joint occasionally present between the conoid tubercle of the clavicle and the superior surface of the horizontal part of the coracoid process. Five hundred and nine clavicles from individuals of different ages were submitted to X-ray examination. Using radiography, we measured the entire length and the index of sinuosity of the anterior lateral curve, on which the distance between the conoid tubercle and the coracoid process depends. We also used radiography to record the differences in prevalence of arthritis in two neighbouring joints, the acromioclavicular and sternoclavicular joints. Of the 1020 clavicles, eight (0.8%) displayed the articular facet of the ccj. No statistical correlation was found between clavicular length and the index of sinuosity of the anterior lateral curve. The prevalence of arthritis in clavicles with ccj was higher than that revealed in clavicles without ccj. The prevalence of ccj in the studied clavicles is lower than that observed in Asian cohorts. Furthermore, ccj is not conditioned by either length or sinuosity of the anterior lateral curve of the clavicle. Finally, the assumption that ccj is a predisposing factor for degenerative changes of neighbouring joints is statistically justified. PMID:12489763

  11. Computational Modelling and Movement Analysis of Hip Joint with Muscles

    NASA Astrophysics Data System (ADS)

    Siswanto, W. A.; Yoon, C. C.; Salleh, S. Md.; Ngali, M. Z.; Yusup, Eliza M.

    2017-01-01

    In this study, the model of hip joint and the main muscles are modelled by finite elements. The parts included in the model are hip joint, hemi pelvis, gluteus maximus, quadratus femoris and gamellus inferior. The materials that used in these model are isotropic elastic, Mooney Rivlin and Neo-hookean. The hip resultant force of the normal gait and stair climbing are applied on the model of hip joint. The responses of displacement, stress and strain of the muscles are then recorded. FEBio non-linear solver for biomechanics is employed to conduct the simulation of the model of hip joint with muscles. The contact interfaces that used in this model are sliding contact and tied contact. From the analysis results, the gluteus maximus has the maximum displacement, stress and strain in the stair climbing. Quadratus femoris and gamellus inferior has the maximum displacement and strain in the normal gait however the maximum stress in the stair climbing. Besides that, the computational model of hip joint with muscles is produced for research and investigation platform. The model can be used as a visualization platform of hip joint.

  12. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    PubMed

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Sensory innervation of the temporomandibular joint in the mouse.

    PubMed

    Dreessen, D; Halata, Z; Strasmann, T

    1990-01-01

    The sensory innervation of the temporomandibular joints (TMJs) of 8 STR/IN mice was investigated by means of light and electron microscopy. Through the cutting of complete semithin sections in series it was possible to investigate the joints thoroughly. Additionally, one joint with its nerve supply was reconstructed three-dimensionally with a computerized three-dimensional programme. The reconstruction was based on one complete semithin section series. The joint's nerve supply originates from the nervus auriculotemporalis and additionally from motor branches of the n. mandibularis: n. massetericus, n. pterygoideus lateralis and the nn. temporales posteriores. The greatest number of nerve fibres and endings is located in the dorsolateral part of the joint capsule. They lie only in the stratum fibrosum and subsynovially. Neither the stratum synoviale nor the discus articularis contain any nerve fibres or endings, whereas the peri-articular loose connective tissue is richly innervated. The only type of nerve ending observed within the joint was the free nerve ending, which is assumed to serve not only as a nociceptor but also as a polymodal mechanoreceptor. Merely within the insertion of the musculus pterygoideus lateralis at the collum mandibulae single stretch receptors of the Ruffini type were observed. Ultrastructurally, they correspond to those described in the cat's knee joint. Neither lamellated nor nerve endings of the Golgi or Pacini type were observed in the joint or in the peri-articular connective tissue. The unexpected paucity of nerve fibres and endings in the TMJ itself of the mouse suggests that the afferent information from the joint is less important for position sense and movement than the afferent information from muscles, tendons and periodontal ligaments.

  14. Facet joint hypertrophy is a misnomer: A retrospective study.

    PubMed

    An, Sang Joon; Seo, Mi Sook; Choi, Soo Il; Lim, Tae-Ha; Shin, So Jin; Kang, Keum Nae; Kim, Young Uk

    2018-06-01

    One of the major causes of lumbar spinal canal stenosis (LSCS) has been considered facet joint hypertrophy (FJH). However, a previous study asserted that "FJH" is a misnomer because common facet joints are no smaller than degenerative facet joints; however, this hypothesis has not been effectively demonstrated. Therefore, in order to verify that FJH is a misnomer in patients with LSCS, we devised new morphological parameters that we called facet joint thickness (FJT) and facet joint cross-sectional area (FJA).We collected FJT and FJA data from 114 patients with LSCS. A total of 86 control subjects underwent lumbar magnetic resonance imaging (MRI) as part of routine medical examinations, and axial T2-weighted MRI images were obtained from all participants. We measured FJT by drawing a line along the facet area and then measuring the narrowest point at L4-L5. We measured FJA as the whole cross-sectional area of the facet joint at the stenotic L4-L5 level.The average FJT was 1.60 ± 0.36 mm in the control group and 1.11 ± 0.32 mm in the LSCS group. The average FJA was 14.46 ± 5.17 mm in the control group and 9.31 ± 3.47 mm in the LSCS group. Patients with LSCS had significantly lower FJTs (P < .001) and FJAs (P < .001).FJH, a misnomer, should be renamed facet joint area narrowing. Using this terminology would eliminate confusion in descriptions of the facet joint.

  15. Chromium content in the human hip joint tissues.

    PubMed

    Brodziak-Dopierała, Barbara; Kwapuliński, Jerzy; Sobczyk, Krzysztof; Wiechuła, Danuta

    2015-02-01

    Chromium has many important functions in the human body. For the osseous tissue, its role has not been clearly defined. This study was aimed at determining chromium content in hip joint tissues. A total of 91 hip joint samples were taken in this study, including 66 from females and 25 from males. The sample tissues were separated according to their anatomical parts. The chromium content was determined by the AAS method. The statistical analysis was performed with U Mann-Whitney's non-parametric test, P≤0.05. The overall chromium content in tissues of the hip joint in the study subjects was as follows: 5.73 µg/g in the articular cartilage, 5.33 µg/g in the cortical bone, 17.86 µg/g in the cancellous bone, 5.95 µg/g in the fragment of the cancellous bone from the intertrochanteric region, and 1.28 µg/g in the joint capsule. The chromium contents were observed in 2 group patients, it was 7.04 µg/g in people with osteoarthritis and 12.59 µg/g in people with fractures. The observed chromium content was highest in the cancellous bone and the lowest in the joint capsule. Chromium content was significantly different between the people with hip joint osteoarthritis and the people with femoral neck fractures. Copyright © 2015 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  16. Disassembly Properties of Cementitious Finish Joints Using an Induction Heating Method

    PubMed Central

    Ahn, Jaecheol; Noguchi, Takafumi; Kitagaki, Ryoma

    2015-01-01

    Efficient maintenance and upgrading of a building during its lifecycle are difficult because a cementitious finish uses materials and parts with low disassembly properties. Additionally, the reuse and recycling processes during building demolition also present numerous problems from the perspective of environmental technology. In this study, an induction heating (IH) method was used to disassemble cementitious finish joints, which are widely used to join building members and materials. The IH rapidly and selectively heated and weakened these joints. The temperature elevation characteristics of the cementitious joint materials were measured as a function of several resistor types, including wire meshes and punching metals, which are usually used for cementitious finishing. The disassembly properties were evaluated through various tests using conductive resistors in cementitious joints such as mortar. When steel fiber, punching metal, and wire mesh were used as conductive resistors, the cementitious modifiers could be weakened within 30 s. Cementitious joints with conductive resistors also showed complete disassembly with little residual bond strength.

  17. Impact extractive fracture of jointed steel plates of a bolted joint

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.

    2012-08-01

    This study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of a bolted joint used in a car body. For the accurate prediction of crash characteristics of car bodies by computer-aided engineering (CAE), it is also necessary to examine the behavior and fracture of jointed steel plates subjected to impact loads. Although the actual impact fracture of jointed steel plates of a bolted joint used in cars is complicated, for simplifying the problem it might be classified into the shear fracture and the extractive fracture of jointed steel plates. Attention is given to the extractive fracture of jointed steel plates in this study. The extractive behavior and fracture of three kinds of steel plates used for cars are examined in experiments and numerical simulations. The impact extraction test of steel plates jointed by a bolt is performed using the one-bar method, together with the static test. In order to understand the mechanism of extractive fracture process of jointed steel plates, numerical simulations by a FEM code LS-DYNA are also carried out. The obtained results suggest that a stress-based fracture criterion may be developed for the impact extractive fracture of jointed steel plates of a bolted joint used in a car body.

  18. Riveting in metal airplane construction. Part III : strength of riveted joints in duralumin (continued)

    NASA Technical Reports Server (NTRS)

    Pleines, Wilhelm

    1930-01-01

    This report includes strength of riveted joints in duralumin, descriptions of test procedure and results of tests. Tabulated data includes: curshing strength by failure for various conditions, shearing strength of hole edge zone in direction of tearing, tearing strengths of plates weakened by rivet holes, and enlargement of holes at beginning of break.

  19. Joint Instability and Osteoarthritis

    PubMed Central

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA. PMID:25741184

  20. Joint instability and osteoarthritis.

    PubMed

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  1. [Trigeminal motor paralysis and dislocation of the temporo-mandibular joints].

    PubMed

    Ohkawa, S; Yoshida, T; Ohsumi, Y; Tabuchi, M

    1996-07-01

    A 64-year-old woman with diabetes mellitus was admitted to our hospital with left hemiparesis of sudden onset. A brain MRI demonstrated a cerebral infarction in the ventral part of the right lower pons. When left hemiparesis worsened, she had dislocation of the temporo-mandibular joints repeatedly. Then, her lower jaw deviated to the right when she opened her mouth. Also, there was decreased contraction of the right masseter when she clenched her teeth. These findings suggest that there was trigeminal motor paralysis on the right side resulting from involvement of the intrapontine trigeminal motor nerve. She has no history of dislocation of the temporo-mandibular joints. An X-ray film showed that the temporo-mandibular joints were intact. Thus, it is possible that deviation of the lower jaw was the cause of this dislocation. We suspect that dislocation of the temporo-mandibular joints may occur as a complication of unilateral trigeminal motor paralysis. This has not been reported to our knowledge.

  2. The hindlimb in walking horses: 2. Net joint moments and joint powers.

    PubMed

    Clayton, H M; Hodson, E; Lanovaz, J L; Colborne, G R

    2001-01-01

    The objective of the study was to describe net joint moments and joint powers in the equine hindlimb during walking. The subjects were 5 sound horses. Kinematic and force data were collected synchronously and combined with morphometric information to determine net joint moments at each hindlimb joint throughout stance and swing. The results showed that the net joint moment was on the caudal/plantar side of all hindlimb joints at the start of stance when the limb was being actively retracted. It moved to the cranial/dorsal side around 24% stride at the hip and stifle and in terminal stance at the more distal joints. It remained on the cranial/dorsal side of all joints during the first half of swing to provide active limb protraction, then moved to the caudal/plantar aspect to reverse the direction of limb motion prior to ground contact. The hip joint was the main source of energy generation throughout the stride. It was assisted by the tarsal joint in both stance and swing phases and by the fetlock joint during the stance phase. The coffin joint acted as an energy damper during stance, whereas the stifle joint absorbed almost equal amounts of energy in the stance and swing phases. The coffin and fetlock joints absorbed energy as the limb was protracted and retracted during the swing phase, suggesting that their movements were driven by inertial forces. Future studies will apply these findings to detect changes in the energy profiles due to specific soft tissue injuries.

  3. An Investigation of the Tensile Strength of a Composite-To-Metal Adhesive Joint

    NASA Astrophysics Data System (ADS)

    Tsouvalis, Nicholas G.; Karatzas, Vassilios A.

    2011-04-01

    The present study examines the feasibility of a simple concept composite-to-metal butt joint through the performance of both numerical and experimental studies. The composite part is made of glass/epoxy unidirectional layers made with the vacuum bag method. The geometry of the joint is typical for marine applications and corresponds to a low stiffness ratio. Two major parameters are investigated, namely the overlap length and the surface preparation of the steel adherent. Manufacturing of specimens and the procedure of the tensile tests are described in detail, giving hints for obtaining a better quality joint. Axial elongation and strains at various places of the joint were monitored and also numerically calculated. The tests revealed that the joint is quite effective, irrespectively of the steel surface preparation method. The failure loads are comparable and in some cases superior to other corresponding values found in the literature. The numerical models proved to adequately predict the structural response of the joint up to the loading where debonding starts.

  4. Root Cause Investigation of Lead-Free Solder Joint Interfacial Failures After Multiple Reflows

    NASA Astrophysics Data System (ADS)

    Li, Yan; Hatch, Olen; Liu, Pilin; Goyal, Deepak

    2017-03-01

    Solder joint interconnects in three-dimensional (3D) packages with package stacking configurations typically must undergo multiple reflow cycles during the assembly process. In this work, interfacial open joint failures between the bulk solder and the intermetallic compound (IMC) layer were found in Sn-Ag-Cu (SAC) solder joints connecting a small package to a large package after multiple reflow reliability tests. Systematic progressive 3D x-ray computed tomography experiments were performed on both incoming and assembled parts to reveal the initiation and evolution of the open failures in the same solder joints before and after the reliability tests. Characterization studies, including focused ion beam cross-sections, scanning electron microscopy, and energy-dispersive x-ray spectroscopy, were conducted to determine the correlation between IMC phase transformation and failure initiation in the solder joints. A comprehensive failure mechanism, along with solution paths for the solder joint interfacial failures after multiple reflow cycles, is discussed in detail.

  5. NASA Thesaurus. Volume 1: Hierarchical listing. Volume 2: Access vocabulary. Volume 3: Definitions

    NASA Technical Reports Server (NTRS)

    1994-01-01

    There are over 17,500 postable terms and some 4,000 nonpostable terms approved for use in the NASA Scientific and Technical Information Database in the Hierarchical Listing of the NASA Thesaurus. The generic structure is presented for many terms. The broader term and narrower term relationships are shown in an indented fashion that illustrates the generic structure better than the more widely used BT and NT listings. Related terms are generously applied, thus enhancing the usefulness of the Hierarchical Listing. Greater access to the Hierarchical Listing may be achieved with the collateral use of Volume 2 - Access Vocabulary and Volume 3 - Definitions.

  6. A Systems Biology Approach to Synovial Joint Lubrication in Health, Injury, and Disease

    PubMed Central

    Hui, Alexander Y.; McCarty, William J.; Masuda, Koichi; Firestein, Gary S.; Sah, Robert L.

    2013-01-01

    The synovial joint contains synovial fluid (SF) within a cavity bounded by articular cartilage and synovium. SF is a viscous fluid that has lubrication, metabolic, and regulatory functions within synovial joints. SF contains lubricant molecules, including proteoglycan-4 and hyaluronan. SF is an ultrafiltrate of plasma with secreted contributions from cell populations lining and within the synovial joint space, including chondrocytes and synoviocytes. Maintenance of normal SF lubricant composition and function are important for joint homeostasis. In osteoarthritis, rheumatoid arthritis, and joint injury, changes in lubricant composition and function accompany alterations in the cytokine and growth factor environment and increased fluid and molecular transport through joint tissues. Thus, understanding the synovial joint lubrication system requires a multi-faceted study of the various parts of the synovial joint and their interactions. Systems biology approaches at multiple scales are being used to describe the molecular, cellular, and tissue components and their interactions that comprise the functioning synovial joint. Analyses of the transcriptome and proteome of SF, cartilage, and synovium suggest that particular molecules and pathways play important roles in joint homeostasis and disease. Such information may be integrated with physicochemical tissue descriptions to construct integrative models of the synovial joint that ultimately may explain maintenance of health, recovery from injury, or development and progression of arthritis. PMID:21826801

  7. The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.

    2012-01-01

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various

  8. Spacesuit mobility knee joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1979-01-01

    Pressure suit mobility joints are for use in interconnecting adjacent segments of an hermetically sealed spacesuit in which low torques, low leakage and a high degree of reliability are required. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics and includes linkages which restrain the joint from longitudinal distension and includes a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  9. Development and validation of a periarticular injection technique of the sacroiliac joint in horses.

    PubMed

    Engeli, E; Haussler, K K; Erb, H N

    2004-05-01

    Sacroiliac joint osteoarthritis has been recognised as a significant cause of poor performance in competition and racehorses. Reliable diagnostic tools are currently lacking. The diagnosis has been based typically on exclusion of other possible causes of poor performance, back pain and hindlimb lameness. To develop a safe, reliable and minimally invasive periarticular or intra-articular injection technique of potential use for diagnosis and therapy of sacroiliac joint disease in horses. Twenty-six horses were used to develop and assess a medial approach to the sacroiliac joint with a 15 gauge, 25 cm long spinal needle. In Part I, the cadaveric study, the spinal needle was introduced cranial to the contralateral tuber sacrale and advanced along the medial aspect of the ipsilateral iliac wing until the dorsal surface of the sacrum was encountered. One ml methylene blue (MB) was injected in both sacroiliac joint regions of the sacropelvic specimens. The location of MB-stained tissues relative to the sacroiliac joints was recorded after dissection and disarticulation of the sacroiliac joint. In Part II, the in vivo study, 18 horses were used to validate the in vivo application of the sacroiliac joint injection technique. Horses were restrained in stocks and sedated in preparation for needle placement. One ml MB was injected bilaterally prior to euthanasia. Stained tissues were identified and recorded at necropsy. Successful joint injections were characterised as having MB located intra-articularly or < or = 2 cm periarticularly from the sacroiliac joint margin and localised to the middle or caudal third of the sacroiliac joint. Intra-articular MB was not observed in any specimen. However, MB-stained tissue was identified periarticularly in all injection sites (n = 48). Based on the predetermined success criteria, 96% of the methylene blue depots were located at the middle or caudal third of the sacroiliac joint. Dye-stained tissue was located < or = 2 cm from the

  10. From intricate to integrated: Biofabrication of articulating joints.

    PubMed

    Groen, Wilhelmina Margaretha; Diloksumpan, Paweena; van Weeren, Paul René; Levato, Riccardo; Malda, Jos

    2017-10-01

    Articulating joints owe their function to the specialized architecture and the complex interplay between multiple tissues including cartilage, bone and synovium. Especially the cartilage component has limited self-healing capacity and damage often leads to the onset of osteoarthritis, eventually resulting in failure of the joint as an organ. Although in its infancy, biofabrication has emerged as a promising technology to reproduce the intricate organization of the joint, thus enabling the introduction of novel surgical treatments, regenerative therapies, and new sets of tools to enhance our understanding of joint physiology and pathology. Herein, we address the current challenges to recapitulate the complexity of articulating joints and how biofabrication could overcome them. The combination of multiple materials, biological cues and cells in a layer-by-layer fashion, can assist in reproducing both the zonal organization of cartilage and the gradual transition from resilient cartilage toward the subchondral bone in biofabricated osteochondral grafts. In this way, optimal integration of engineered constructs with the natural surrounding tissues can be obtained. Mechanical characteristics, including the smoothness and low friction that are hallmarks of the articular surface, can be tuned with multi-head or hybrid printers by controlling the spatial patterning of printed structures. Moreover, biofabrication can use digital medical images as blueprints for printing patient-specific implants. Finally, the current rapid advances in biofabrication hold significant potential for developing joint-on-a-chip models for personalized medicine and drug testing or even for the creation of implants that may be used to treat larger parts of the articulating joint. © 2017 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 35:2089-2097, 2017. © 2017 The Authors. Journal of Orthopaedic

  11. Joint Enabling Capabilities Command

    Science.gov Websites

    Executive Director Chief of Staff Joint Planning Support Element Joint Communications Support Element mission Joint Enabling Capabilities Command provides decisive joint communications, planning and public and responsive support for joint communications, planning and public affairs. Priorities * Deliver

  12. Practitioner-provider joint ventures, the OIG, and the IRS.

    PubMed

    MacKelvie, C F; Handler, M S; Sanborn, A B

    1992-11-01

    Increased forays by hospitals and physicians into joint ventures make both parties subject to a complex network of laws and regulations and to scrutiny by many Federal agencies. Institutional healthcare providers should be aware of the legal pitfalls and exercise extreme caution when creating such arrangements. This is the second of a two-part examination of issues relative to taxes and Medicare and Medicaid fraud and abuse regulations. (Part I was published in the October 1992 issue of HFM.)

  13. Results and Analysis from Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer E.; Aitchison, Lindsay

    2009-01-01

    A space suit s mobility is critical to an astronaut s ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. The term mobility, with respect to space suits, is defined in terms of two key components: joint range of motion and joint torque. Individually these measures describe the path which in which a joint travels and the force required to move it through that path. Previous space suits mobility requirements were defined as the collective result of these two measures and verified by the completion of discrete functional tasks. While a valid way to impose mobility requirements, such a method does necessitate a solid understanding of the operational scenarios in which the final suit will be performing. Because the Constellation space suit system requirements are being finalized with a relatively immature concept of operations, the Space Suit Element team elected to define mobility in terms of its constituent parts to increase the likelihood that the future pressure garment will be mobile enough to enable a broad scope of undefined exploration activities. The range of motion requirements were defined by measuring the ranges of motion test subjects achieved while performing a series of joint maximizing tasks in a variety of flight and prototype space suits. The definition of joint torque requirements has proved more elusive. NASA evaluated several different approaches to the problem before deciding to generate requirements based on unmanned joint torque evaluations of six different space suit configurations being articulated through 16 separate joint movements. This paper discusses the experiment design, data analysis and results, and the process used to determine the final values for the Constellation pressure garment joint torque requirements.

  14. Family joint activities in a cross-national perspective.

    PubMed

    Zaborskis, Apolinaras; Zemaitiene, Nida; Borup, Ina; Kuntsche, Emmanuel; Moreno, Carmen

    2007-05-30

    Parents and children joint activities are considered to be an important factor on healthy lifestyle development throughout adolescence. This study is a part of the Cross-National Survey on Health Behaviour in School-aged Children--World Health Organization Collaborative Study (HBSC). It aims to describe family time in joint activities and to clarify the role of social and structural family profile in a cross-national perspective. The research was carried out according to the methodology of the HBSC study using the anonymous standardized questionnaire. In total, 17,761 students (8,649 boys and 9,112 girls) aged 13 and 15 years from 6 European countries (Czech Republic, Finland, Greenland, Lithuania, Spain, and Ukraine) were surveyed in the 2001-2002 school-year. The evaluation of joint family activity is based on 8 items: (1) watching TV or a video, (2) playing indoor games, (3) eating meals, (4) going for a walk, (5) going places, (6) visiting friends or relatives, (7) playing sports, (8) sitting and talking about things (chatting). Students from Spain and Ukraine reported spending the most time together with their families in almost all kinds of joint activities, whereas students from Greenland and Finland reported spending the least of this time. Boys were more likely than girls to be spending time together with family. Joint family activity goes into decline in age from 13 to 15 years. Variability of family time in a cross-national perspective was relatively small and related to children age category. Considering national, gender and age differences of studied population groups, we found that the distribution of joint family activities tends to be dispersed significantly by family structure (intact/restructured family) and family wealth. Our study compares children and parent joint activities in European countries and reveals differences and similarities in these patterns between countries. The findings underline the role of family structure (intact

  15. MP Joint Arthritis

    MedlinePlus

    ... is extensive and severe, joint replacement or joint fusion are effective surgical options. Learn more about joint ... the tabs at the top (Video, Articles/WEB, Images, JHS, Products/Vendors), or the filters on the ...

  16. [The clinical value of cartilaginous surface and corresponding osseous contour of patellofemoral joint].

    PubMed

    Zhang, Jian-Bing; Chen, Bai-Cheng; Zhang, Jing; Wang, Zhi-Qiang; Yan, Chang-Bao

    2010-11-15

    to investigate if the cartilaginous surface and corresponding osseous contour of the patellofemoral joint match in the axial plane for providing theoretical basis with evaluating alignment of patellofemoral joint and designing the part of patellofemoral joint in knee prosthesis. from January 2009 to March 2010, 9 human cadaver knees were prepared, which chandra of patellofemoral joint didn't degenerate. Each specimen was sectioned in the axial plane at 20° to 30° knee flax. The cross-sections revealed characteristics in the bony anatomy and corresponding articular surface geometry of the patellofemoral joint in the axial plane. Evaluating parameters included osseous patella congruence angle (OPCA), chondral patella congruence angle (CPCA), patella chondral convex point parameter (PCCPP), patella subchondral osseous convex point parameter (PSOCPP), the parameters of the deepest (chondral or osseous) point of the intercondylar sulcus. After that, the osseous and cartilaginous contours and subchondral osseous contours of the patella in the axial plane were analyzed through MRI data of 11 patients who didn't degenerate in patellofemoral joint cartilage. Parameters as same as cadaver knees were compared. data from specimens of OPCA was (-4.5 ± 1.1)°, CPCA was (0.5 ± 0.8)°, PCCPP was 1.13 ± 0.11, PSOCPP was 1.67 ± 0.14, PCDPIS was 1.35 ± 0.28, PODPIS was 1.38 ± 0.33. Date from MRI of OPCA was (-3.8 ± 1.4)°, CPCA was (0.7 ± 1.0)°, PCCPP was 1.05 ± 0.21, PSOCPP was 1.73 ± 0.18, PCDPIS was 1.41 ± 0.21, PODPIS was 1.37 ± 0.27. The patella exhibited significant differences in the bony vs. chondral anatomy (P < 0.05), but the intercondylar sulcus nearly match in the bony vs. chondral anatomy. the cartilaginous surface and corresponding osseous contour of the patella don't match in the patellofemoral joint axial plane, but that of the trochlea nearly matches. This is very important for accurately evaluating alignment of patellofemoral joint because the normal

  17. A Case of Acromioclavicular Joint Dislocation Associated with Coracoid Process Fracture.

    PubMed

    Nakamura, Yosuke; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Yoshikawa, Eiichiro; Uryu, Takuya; Murakami, Hidetaka; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2015-01-01

    Rupture of any two or more parts of the superior shoulder suspensory complex (SSSC) including the distal clavicle, acromion, coracoid process, glenoid cavity of the scapula, acromioclavicular ligament, and coracoclavicular ligament is associated with shoulder girdle instability and is an indication for surgery. Here we report a case of acromioclavicular joint dislocation associated with coracoid process fracture. A 48-year-old man sustained a hard blow to the left shoulder from a fall, and simple radiography detected a coracoid process fracture and acromioclavicular joint dislocation. The injury consisted of a rupture of two parts of the SSSC. For the coracoid process fracture, osteosynthesis was performed using hollow cancellous bone screws. For the acromioclavicular joint dislocation, hook plate fixation and the modified Neviaser's procedure were performed. The bone healed well 5 months after surgery, at which time the screws were removed. At 18 months after initial surgery, the coracoid process fracture had healed with a 10% rate of dislocation on radiography, and the patient currently has no problem performing daily activities, no range of motion limitations, and a Japanese Orthopaedic Association scale score of 93.

  18. Antigenicity of mesenchymal stem cells in an inflamed joint environment.

    PubMed

    Hill, Jacqueline A; Cassano, Jennifer M; Goodale, Margaret B; Fortier, Lisa A

    2017-07-01

    OBJECTIVE To determine whether major histocompatability complex (MHC) class II expression in equine mesenchymal stem cells (MSCs) changes with exposure to a proinflammatory environment reflective of an inflamed joint. SAMPLE Cryopreserved bone marrow-derived MSCs from 12 horses and cartilage and synovium samples from 1 horse euthanized for reasons other than lameness. PROCEDURES In part 1 of a 3-part study, the suitability of a quantitative reverse transcriptase PCR (qRT-PCR) assay for measurement of MHC class II expression in MSCs following stimulation with interferon (IFN)-γ was assessed. In part 2, synoviocyte-cartilage cocultures were or were not stimulated with interleukin (IL)-1β (10 ng/mL) to generate conditioned media that did and did not (control) mimic an inflamed joint environment. In part 3, a qRT-PCR assay was used to measure MSC MHC class II expression after 96 hours of incubation with 1 of 6 treatments (control-conditioned medium, IL-1β-conditioned medium, and MSC medium alone [untreated control] or with IL-1β [10 ng/mL], tumor necrosis factor-α [10 ng/mL], or IFN-γ [100 ng/mL]). RESULTS The qRT-PCR assay accurately measured MHC class II expression. Compared with MHC class II expression for MSCs exposed to the untreated control medium, that for MSCs exposed to IL-1β was decreased, whereas that for MSCs exposed to IFN-γ was increased. Neither the control-conditioned nor tumor necrosis factor-α medium altered MHC class II expression. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that MSC exposure to proinflammatory cytokine IL-1β decreased MHC class II expression and antigenicity. Treatment of inflamed joints with allogeneic MSCs might not be contraindicated, but further investigation is warranted.

  19. Improved TIG weld joint strength in aluminum alloy 2219-T87 by filler metal substitution

    NASA Technical Reports Server (NTRS)

    Poorman, R. M.; Lovoy, C. V.

    1972-01-01

    The results of an investigation on weld joint characteristics of aluminum alloy 2219-T87 are given. Five different alloys were utilized as filler material. The mechanical properties of the joints were determined at ambient and cryogenic temperatures for weldments in the as-welded condition and also, for weldments after elevated temperature exposures. Other evaluations included hardness surveys, stress corrosion susceptibility, and to a limited extent, the internal metallurgical weld structures. The overall results indicate that M-943 filler weldments are superior in strength to weldments containing either the standard 2319 filler or fillers 2014, 2020, and a dual wire feed consisting of three parts 2319 and one part 5652. In addition, no deficiencies were evident in M-934 filler weldments with regard to ductility, joint strength after elevated temperature exposure, weld hardness, metallographic structures, or stress corrosion susceptibility.

  20. An all-joint-control master device for single-port laparoscopic surgery robots.

    PubMed

    Shim, Seongbo; Kang, Taehun; Ji, Daekeun; Choi, Hyunseok; Joung, Sanghyun; Hong, Jaesung

    2016-08-01

    Robots for single-port laparoscopic surgery (SPLS) typically have all of their joints located inside abdomen during surgery, whereas with the da Vinci system, only the tip part of the robot arm is inserted and manipulated. A typical master device that controls only the tip with six degrees of freedom (DOFs) is not suitable for use with SPLS robots because of safety concerns. We designed an ergonomic six-DOF master device that can control all of the joints of an SPLS robot. We matched each joint of the master, the slave, and the human arm to decouple all-joint motions of the slave robot. Counterbalance masses were used to reduce operator fatigue. Mapping factors were determined based on kinematic analysis and were used to achieve all-joint control with minimal error at the tip of the slave robot. The proposed master device has two noteworthy features: efficient joint matching to the human arm to decouple each joint motion of the slave robot and accurate mapping factors, which can minimize the trajectory error of the tips between the master and the slave. We confirmed that the operator can manipulate the slave robot intuitively with the master device and that both tips have similar trajectories with minimal error.

  1. Joint sealant study

    DOT National Transportation Integrated Search

    1987-09-01

    ADOT has approximately 550 lane miles of jointed portland cement pavement under its jurisdiction. The current practice is to saw and seal the joints at the time of construction and reseal the joints under a rehabilitation project. ADOT does not speci...

  2. Use of joint-growth directions and rock textures to infer thermal regimes during solidification of basaltic lava flows

    NASA Astrophysics Data System (ADS)

    Degraff, James M.; Long, Philip E.; Aydin, Atilla

    1989-09-01

    Thermal contraction joints form in the upper and lower solidifying crusts of basaltic lava flows and grow toward the interior as the crusts thicken. Lava flows are thus divided by vertical joints that, by changes in joint spacing and form, define horizontal intraflow layers known as tiers. Entablatures are tiers with joint spacings less than about 40 cm, whereas colonnades have larger joint spacings. We use structural and petrographic methods to infer heat-transfer processes and to constrain environmental conditions that produce these contrasting tiers. Joint-surface morphology indicates overall joint-growth direction and thus identifies the level in a flow where the upper and lower crusts met. Rock texture provides information on relative cooling rates in the tiers of a flow. Lava flows without entablature have textures that develop by relatively slow cooling, and two joint sets that usually meet near their middles, which indicate mostly conductive cooling. Entablature-bearing flows have two main joint sets that meet well below their middles, and textures that indicate fast cooling of entablatures and slow cooling of colonnades. Entablatures always occur in the upper joint sets and sometimes alternate several times with colonnades. Solidification times of entablature-bearing flows, constrained by lower joint-set thicknesses, are much less than those predicted by a purely conductive cooling model. These results are best explained by a cooling model based on conductive heat transfer near a flow base and water-steam convection in the upper part of an entablature-bearing flow. Calculated solidification rates in the upper parts of such flows exceed that of the upper crust of Kilauea Iki lava lake, where water-steam convection is documented. Use of the solidification rates in an available model of water-steam convection yields permeability values that agree with measured values for fractured crystalline rock. We conclude, therefore, that an entablature forms when part

  3. Development of biomimetic quadruped walking robot with 2-DOF waist joint

    NASA Astrophysics Data System (ADS)

    Kim, Kyoung-Ho; Park, Se-Hoon; Lee, Yun-Jung

    2005-12-01

    This paper presented a novel bio-mimetic quadruped walking robot with 2-DOF (Degree Of Freedom) waist joint, which connects the front and the rear parts of the body. The waist-jointed walking robot can guarantee more stable and more animal-like gait than that of a conventional single-rigid-body walking robot. The developed robot, called ELIRO-II (Eating LIzard RObot version 2), can bend its body from side to side by using 1-DOF passive waist joint while the legs is transferred, thereby increasing the stride and speed of the robot. In addition, ELIRO-II has one more active DOF to bend its body up and down, which increases the mobility in irregular terrain such as slope and stairs. We design the mechanical structure of the robot, which is small and light to have high mobility. This research described characteristics of the 2-DOF waists joint and leg mechanism as well as a hardware and software of the controller of ELIRO-II.

  4. Regular paths in SparQL: querying the NCI Thesaurus.

    PubMed

    Detwiler, Landon T; Suciu, Dan; Brinkley, James F

    2008-11-06

    OWL, the Web Ontology Language, provides syntax and semantics for representing knowledge for the semantic web. Many of the constructs of OWL have a basis in the field of description logics. While the formal underpinnings of description logics have lead to a highly computable language, it has come at a cognitive cost. OWL ontologies are often unintuitive to readers lacking a strong logic background. In this work we describe GLEEN, a regular path expression library, which extends the RDF query language SparQL to support complex path expressions over OWL and other RDF-based ontologies. We illustrate the utility of GLEEN by showing how it can be used in a query-based approach to defining simpler, more intuitive views of OWL ontologies. In particular we show how relatively simple GLEEN-enhanced SparQL queries can create views of the OWL version of the NCI Thesaurus that match the views generated by the web-based NCI browser.

  5. Chimpanzee ankle and foot joint kinematics: Arboreal versus terrestrial locomotion.

    PubMed

    Holowka, Nicholas B; O'Neill, Matthew C; Thompson, Nathan E; Demes, Brigitte

    2017-09-01

    Many aspects of chimpanzee ankle and midfoot joint morphology are believed to reflect adaptations for arboreal locomotion. However, terrestrial travel also constitutes a significant component of chimpanzee locomotion, complicating functional interpretations of chimpanzee and fossil hominin foot morphology. Here we tested hypotheses of foot motion and, in keeping with general assumptions, we predicted that chimpanzees would use greater ankle and midfoot joint ranges of motion during travel on arboreal supports than on the ground. We used a high-speed motion capture system to measure three-dimensional kinematics of the ankle and midfoot joints in two male chimpanzees during three locomotor modes: terrestrial quadrupedalism on a flat runway, arboreal quadrupedalism on a horizontally oriented tree trunk, and climbing on a vertically oriented tree trunk. Chimpanzees used relatively high ankle joint dorsiflexion angles during all three locomotor modes, although dorsiflexion was greatest in arboreal modes. They used higher subtalar joint coronal plane ranges of motion during terrestrial and arboreal quadrupedalism than during climbing, due in part to their use of high eversion angles in the former. Finally, they used high midfoot inversion angles during arboreal locomotor modes, but used similar midfoot sagittal plane kinematics across all locomotor modes. The results indicate that chimpanzees use large ranges of motion at their various ankle and midfoot joints during both terrestrial and arboreal locomotion. Therefore, we argue that chimpanzee foot anatomy enables a versatile locomotor repertoire, and urge caution when using foot joint morphology to reconstruct arboreal behavior in fossil hominins. © 2017 Wiley Periodicals, Inc.

  6. Influence of micro-oxidation on joints of C/C composites and GH3044 for large-size aerospace parts

    NASA Astrophysics Data System (ADS)

    Shi, Xiaohong; Jin, Xiuxiu; Yan, Ningning; Yang, Li

    2017-11-01

    To improve the bonding strength of carbon/carbon (C/C) composites and GH3044 nickel-based superalloy, the bonding interlayer with Ti/Ni/Cu/Ni multiple foils were prepared by a two-step technique involving micro-oxidation and partial transient liquid phase (PTLP) process. Interface characteristics and mechanical behavior of joints were investigated by scanning electron microscopy (SEM), X-ray diffraction (XRD), laser scanning confocal microscope (LSCM) and energy X-ray dispersive spectrometer (EDS). Results show that a porous layer on C/C composites is formed by micro-oxidation for more than 2 min at 1073 K in air, which provides a diffusion path for liquid phase to infiltrate into C/C substrate and generate a wedge interlocking interface. After micro-oxidation for 4 min, the shear strength of joints reaches 32.09 ± 1.98 MPa what is 36.73% higher than that of joints without micro-oxidation (23.47 ± 1.15 MPa). The increase of shear strength remarkably depends on physical interlocking and chemical bonding at porous interface.

  7. [Factors affecting the localization of joints in rheumatoid arthritis].

    PubMed

    Keitel, W; Wellmann, C; Gedschold, A; Wille, R

    1981-03-15

    For testing a possible connection between the localization of a joint and anthropometric data in rheumatoid arthritis the numbers of a maximum and minimum affection in the region of the hand were at first determined. Former findings of a more frequent participation of the right hand could be confirmed. In the region of the distal skeleton of the hand the changes were to be found more radially, in the proximal parts more frequently ulnarly. Examinations concerning the influence of the breadth, length and angular measures of the hand showed above all connections of the affection of the joints with the breadth of the hand. An influence of measures and indices of the body on the frequency of the affection of peripheral joints could statistically ascertained only for few of the constellations examined. Future investigations shall take into consideration the regional vessel and nerve supply, shall issue from homogeneous groups of test persons and shall be performed with other methods of evaluation.

  8. Radiating columnar joints in Gyeongju, Korea as a educational site

    NASA Astrophysics Data System (ADS)

    Woo, H.; Kim, J. H.; Jang, Y. D.

    2015-12-01

    Gyeongju is located in the central eastern part of South Korea. There are various directional columnar joint sets in Tertiary trachytic basalt formation along the shore. In particular, rare radiating columnar joints occur in this area. Columnar joints are parallel, prismatic columns that are formed as a result of contraction during the rapid cooling of lava flow, forming a three dimensional fracture network. In general, the radius and direction of the rock column represent the cooling rate and surface respectively. Radiating direction of columns here indicates that dome- or lobe-shaped lava was cooled from its surface to the core during the viscous lava flow. The fact that the trachytic textures of plagioclase laths are indistinct suggests that the radiating columnar joints are equivalent to the frontal end of the lava lobes. This area is currently has a shore trail course, which is being developed into a picturesque educational park. There are corresponding information boards on the trail near each type of columnar joints to explain not only the forming process and geological mechanisms but the importance of nature conservation to visitors, especially students. A variety of educational materials and educational programs linked to regular school curriculum are also being developed.

  9. Joint swelling

    MedlinePlus

    ... of arthritis caused by buildup of uric acid crystals in a joint ( gout ) Arthritis caused by wear ... osteoarthritis ) Arthritis caused by buildup of calcium-type crystals in joints ( pseudogout ) Disorder that involves arthritis and ...

  10. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices... Medical Devices—Part I: Evaluation and Testing,’ ” (ii) “510(k) Sterility Review Guidance of 2/12/90 (K90... device intended to be implanted to replace part of a knee joint in the treatment of primary...

  11. The joint flanker effect and the joint Simon effect: On the comparability of processes underlying joint compatibility effects.

    PubMed

    Dittrich, Kerstin; Bossert, Marie-Luise; Rothe-Wulf, Annelie; Klauer, Karl Christoph

    2017-09-01

    Previous studies observed compatibility effects in different interference paradigms such as the Simon and flanker task even when the task was distributed across two co-actors. In both Simon and flanker tasks, performance is improved in compatible trials relative to incompatible trials if one actor works on the task alone as well as if two co-actors share the task. These findings have been taken to indicate that actors automatically co-represent their co-actor's task. However, recent research on the joint Simon and joint flanker effect suggests alternative non-social interpretations. To which degree both joint effects are driven by the same underlying processes is the question of the present study, and it was scrutinized by manipulating the visibility of the co-actor. While the joint Simon effect was not affected by the visibility of the co-actor, the joint flanker effect was reduced when participants did not see their co-actors but knew where the co-actors were seated. These findings provide further evidence for a spatial interpretation of the joint Simon effect. In contrast to recent claims, however, we propose a new explanation of the joint flanker effect that attributes the effect to an impairment in the focusing of spatial attention contingent on the visibility of the co-actor.

  12. The effect of brazing parameters on corrosion behavior of brazed aluminum joints

    NASA Astrophysics Data System (ADS)

    Ghasimakbari, Farzam; Hadian, Ali Mohammad; Ershadrad, Soheil; Omidazad, Amir Mansour

    2018-01-01

    Fluid transmission pipes made of aluminum are widely used in petrochemical industries. For many applications, they have to be brazed to each other. The brazed joints, in many cases, are encountered with corrosive medias. This paper reports a part of a work to investigate the corrosion behavior of brazed AA6061 using AA4047 as filler metal with and without the use of flux under different brazing atmospheres. The samples brazed under air, vacuum, argon, and hydrogen atmospheres. The interfacial area of the joints was examined to ensure being free of any defects. The sides of each test piece were covered with an insulator and the surface of the joint was encountered to polarization test. The results revealed a significant difference of corrosion resistance. The samples that brazed under argon and hydrogen atmospheres had better corrosion resistance than other samples. The microstructure of the corroded joints revealed that the presence of defects, impurities due to use of flux and depth of filter metal penetration in base metal are crucial variables on the corrosion resistance of the joints.

  13. Experimental and numerical study of Bondura® 6.6 PIN joints

    NASA Astrophysics Data System (ADS)

    Berkani, I.; Karlsen, Ø.; Lemu, H. G.

    2017-12-01

    Pin joints are widely used in heavy-duty machinery such as aircrafts, cranes and offshore drilling equipment to transfer multi-dimensional shear forces. Their strength and service life depend on the clamping force in the contact region that is provided by interference fits. Though the interference fits provide full contact at the pin-hole interface under pretension loads, the contact interface reduces when the pin is subjected to an external load and hence a smaller contact surface leads to dramatic increase of the contact stress. The PIN joint of Bondura® Technology, investigated in this study, is an innovative solution intended to reduce the slack at the contact surface of the pin joint of heavy-duty machinery by using tapered sleeves on each end of the PIN. The study is aimed to better understand the contact pressure build-up and stress distribution in the supporting contact surface under pre-loading of the joint and the influence of temperature difference between part assembly and operation conditions. Numerical simulation using finite element method and diverse experimental tests were conducted. The numerical simulation and the test results, particularly the tests conducted with lubricated joints, show good conformance.

  14. Susceptibility of lava domes to erosion and collapse by toppling on cooling joints

    NASA Astrophysics Data System (ADS)

    Smith, John V.

    2018-01-01

    The shape of lava domes typically leads to the formation of radial patterns of cooling joints. These cooling joints define the orientation of the columnar blocks which plunge toward the center of the dome. In the lower parts of the dome the columns plunge into the dome at low angles and are relatively stable. Higher in the dome the columns plunge into the dome at steep angles. These steeply plunging columns are susceptible to toppling and, if the lower part of a dome is partially removed by erosion or collapse, the unstable part of the dome becomes exposed leading to toppling failure. Examples of this process are provided from coastal erosion of lava domes at Katsura Island, Shimane Peninsula, western Japan. An analogue model is presented to demonstrate the mechanism. It is proposed that the mechanism can contribute to collapse of lava domes during or after emplacement.

  15. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    NASA Astrophysics Data System (ADS)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  16. More than the sum of the parts: forest climate response from joint species distribution models

    Treesearch

    James S. Clark; Alan E. Gelfand; Christopher W. Woodall; Kai Zhu

    2014-01-01

    The perceived threat of climate change is often evaluated from species distribution models that are fitted to many species independently and then added together. This approach ignores the fact that species are jointly distributed and limit one another. Species respond to the same underlying climatic variables, and the abundance of any one species can be constrained by...

  17. Review: Modelling of meniscus of knee joint during soccer kicking

    NASA Astrophysics Data System (ADS)

    Azrul Hisham Mohd Adib, Mohd; Firdaus Jaafar, Mohd

    2013-12-01

    Knee is a part of the body that located between thigh and shank is one of the most complicated and largest joints in the human body. The common injuries that occur are ligaments, meniscus or bone fracture. During soccer games, the knee is the most critical part that will easily injure due to the shock from an external impact. Torn meniscus is one of the effects. This study will investigate the effect towards the meniscus within the knee joint during soccer ball kicking. We conduct a literary review of 14 journals that discuss the general view of meniscus and also soccer kicking. The selected topics for this review paper are meniscal function, meniscal movement, meniscal tears and also instep kick. As a finding, statistics show that most meniscal tears (73%) occurred in athletes who were soccer players, basketball players or skiers. The tear is frequently happening at the medial side rather than lateral side with a percentage of 70%.

  18. Mutual coordination strengthens the sense of joint agency in cooperative joint action.

    PubMed

    Bolt, Nicole K; Poncelet, Evan M; Schultz, Benjamin G; Loehr, Janeen D

    2016-11-01

    Philosophers have proposed that when people coordinate their actions with others they may experience a sense of joint agency, or shared control over actions and their effects. However, little empirical work has investigated the sense of joint agency. In the current study, pairs coordinated their actions to produce tone sequences and then rated their sense of joint agency on a scale ranging from shared to independent control. People felt more shared than independent control overall, confirming that people experience joint agency during joint action. Furthermore, people felt stronger joint agency when they (a) produced sequences that required mutual coordination compared to sequences in which only one partner had to coordinate with the other, (b) held the role of follower compared to leader, and (c) were better coordinated with their partner. Thus, the strength of joint agency is influenced by the degree to which people mutually coordinate with each other's actions. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Joint Chiefs of Staff > Leadership

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Structure Joint Staff Organizational Chart Joint Chiefs of Staff Links Home Today in DOD About DOD Top Issues News Photos/Videos

  20. Temporomandibular disorders. Part 2: conservative management

    PubMed Central

    Shaffer, Stephen M; Brismée, Jean-Michel; Sizer, Phillip S; Courtney, Carol A

    2014-01-01

    Appropriate management of temporomandibular disorders (TMD) requires an understanding of the underlying dysfunction associated with the temporomandibular joint (TMJ) and surrounding structures. A comprehensive examination process, as described in part 1 of this series, can reveal underlying clinical findings that assist in the delivery of comprehensive physical therapy services for patients with TMD. Part 2 of this series focuses on management strategies for TMD. Physical therapy is the preferred conservative management approach for TMD. Physical therapists are professionally well-positioned to step into the void and provide clinical services for patients with TMD. Clinicians should utilize examination findings to design rehabilitation programs that focus on addressing patient-specific impairments. Potentially appropriate plan of care components include joint and soft tissue mobilization, trigger point dry needling, friction massage, therapeutic exercise, patient education, modalities, and outside referral. Management options should address both symptom reduction and oral function. Satisfactory results can often be achieved when management focuses on patient-specific clinical variables. PMID:24976744

  1. Signaling networks in joint development

    PubMed Central

    Salva, Joanna E.; Merrill, Amy E.

    2016-01-01

    Here we review studies identifying regulatory networks responsible for synovial, cartilaginous, and fibrous joint development. Synovial joints, characterized by the fluid-filled synovial space between the bones, are found in high-mobility regions and are the most common type of joint. Cartilaginous joints unite adjacent bones through either a hyaline cartilage or fibrocartilage intermediate. Fibrous joints, which include the cranial sutures, form a direct union between bones through fibrous connective tissue. We describe how the distinct morphologic and histogenic characteristics of these joint classes are established during embryonic development. Collectively, these studies reveal that despite the heterogeneity of joint strength and mobility, joint development throughout the skeleton utilizes common signaling networks via long-range morphogen gradients and direct cell-cell contact. This suggests that different joint types represent specialized variants of homologous developmental modules. Identifying the unifying aspects of the signaling networks between joint classes allows a more complete understanding of the signaling code for joint formation, which is critical to improving strategies for joint regeneration and repair. PMID:27859991

  2. Support and Development of Workflow Protocols for High Throughput Single-Lap-Joint Testing-Experimental

    DTIC Science & Technology

    2013-04-01

    preparation, and presence of an overflow fillet for a high strength epoxy and ductile methacylate adhesive. A unique feature of this study was the...of expanding adhesive joint test configurations as part of the GEMS program. 15. SUBJECT TERMS single lap joint, adhesion, aluminum, epoxy ... epoxy and ductile methacylate adhesive. A unique feature of this study was the use of untrained GEMS (Gains in the Education of Mathematics and Sci

  3. Microstructure of friction stir welded joints of 2017A aluminium alloy sheets.

    PubMed

    Mroczka, K; Dutkiewicz, J; Pietras, A

    2010-03-01

    The present study examines a friction stir welded 2017A aluminium alloy. Transmission electron microscope investigations of the weld nugget revealed the average grain size of 5 microm, moderate density of dislocations as well as the presence of nanometric precipitates located mostly in grains interiors. Scanning electron microscope observations of fractures showed the presence of ductile fracture in the region of the weld nugget with brittle precipitates in the lower part. The microhardness analysis performed on the cross-section of the joints showed fairly small changes; however, after the artificial ageing process an increase in hardness was observed. The change of the joint hardness subject to the ageing process indicates partial supersaturation in the material during friction stir welding and higher precipitation hardening of the joint.

  4. Mobile Phone-Based Joint Angle Measurement for Functional Assessment and Rehabilitation of Proprioception

    PubMed Central

    Mourcou, Quentin; Fleury, Anthony; Diot, Bruno; Franco, Céline; Vuillerme, Nicolas

    2015-01-01

    Assessment of joint functional and proprioceptive abilities is essential for balance, posture, and motor control rehabilitation. Joint functional ability refers to the capacity of movement of the joint. It may be evaluated thereby measuring the joint range of motion (ROM). Proprioception can be defined as the perception of the position and of the movement of various body parts in space. Its role is essential in sensorimotor control for movement acuity, joint stability, coordination, and balance. Its clinical evaluation is commonly based on the assessment of the joint position sense (JPS). Both ROM and JPS measurements require estimating angles through goniometer, scoliometer, laser-pointer, and bubble or digital inclinometer. With the arrival of Smartphones, these costly clinical tools tend to be replaced. Beyond evaluation, maintaining and/or improving joint functional and proprioceptive abilities by training with physical therapy is important for long-term management. This review aims to report Smartphone applications used for measuring and improving functional and proprioceptive abilities. It identifies that Smartphone applications are reliable for clinical measurements and are mainly used to assess ROM and JPS. However, there is lack of studies on Smartphone applications which can be used in an autonomous way to provide physical therapy exercises at home. PMID:26583101

  5. Maloti Drakensberg Transfrontier Park joint management: Sehlabathebe National Park (Lesotho) and the uKhahlamba Drakensberg Park World Heritage Site (South Africa)

    Treesearch

    John M. Crowson

    2011-01-01

    On 8 April 2005, the first Joint Management Committee meeting was held at Qacha's Nek, Lesotho. This was to ensure co-operative management through joint management. The formation of a Joint Management Committee was part of the Bilateral Maloti Drakensberg Transfrontier Project agreement and consisted of officials from the Ministry of Tourism, Environment and...

  6. A guided tour of current research in synovial joints with reference to wavelet methodology

    NASA Astrophysics Data System (ADS)

    Agarwal, Ruchi; Salimath, C. S.; Alam, Khursheed

    2017-10-01

    Main aim of this article is to provide a comprehensive overview of biomechanical aspects of synovial joints of human body. This can be considered as a part of continued research work carried out by various authors over a period of time. Almost every person once in life time has suffered from joint disease; this has triggered intensive investigation into various biomechanical aspects of synovial joints. This has also resulted into an increase of arthroplasty with introduction to various clinical trials. From last few decades new improvements and ideas for new technologies have been introduced to decrease the incidence of joint problem. In this paper a literature survey of recent advances, developments and recognition of wear and tear of human joint is presented. Wavelet method in Computational fluid dynamics (CFD) is relatively a new research field. This review aims to provide a glimpse of wavelet methodology in CFD. Wavelets methodology has played a vital role in the solution of governing equation of synovial fluid flow in the synovial joints represented by Reynolds equation and its modified version.

  7. Geomechanical Response of Jointed Caprock During CO2 Geological Sequestration

    NASA Astrophysics Data System (ADS)

    Newell, P.; Martinez, M. J.; Bishop, J. E.

    2014-12-01

    Geological sequestration of CO2 refers to the injection of supercritical CO2 into deep reservoirs trapped beneath a low-permeability caprock formation. Maintaining caprock integrity during the injection process is the most important factor for a successful injection. In this work we evaluate the potential for jointed caprock during injection scenarios using coupled three-dimensional multiphase flow and geomechanics modeling. Evaluation of jointed/fractured caprock systems is of particular concern to CO2 sequestration because creation or reactivation of joints (mechanical damage) can lead to enhanced pathways for leakage. In this work, we use an equivalent continuum approach to account for the joints within the caprock. Joint's aperture and non-linear stiffness of the caprock will be updated dynamically based on the effective normal stress. Effective permeability field will be updated based on the joints' aperture creating an anisotropic permeability field throughout the caprock. This feature would add another coupling between the solid and fluid in addition to basic Terzaghi's effective stress concept. In this study, we evaluate the impact of the joint's orientation and geometry of caprock and reservoir layers on geomechanical response of the CO2 geological systems. This work is supported as part of the Center for Frontiers of Subsurface Energy Security, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Award Number DE-SC0001114. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  8. Novel joint cupping clinical maneuver for ultrasonographic detection of knee joint effusions.

    PubMed

    Uryasev, Oleg; Joseph, Oliver C; McNamara, John P; Dallas, Apostolos P

    2013-11-01

    Knee effusions occur due to traumatic and atraumatic causes. Clinical diagnosis currently relies on several provocative techniques to demonstrate knee joint effusions. Portable bedside ultrasonography (US) is becoming an adjunct to diagnosis of effusions. We hypothesized that a US approach with a clinical joint cupping maneuver increases sensitivity in identifying effusions as compared to US alone. Using unembalmed cadaver knees, we injected fluid to create effusions up to 10 mL. Each effusion volume was measured in a lateral transverse location with respect to the patella. For each effusion we applied a joint cupping maneuver from an inferior approach, and re-measured the effusion. With increased volume of saline infusion, the mean depth of effusion on ultrasound imaging increased as well. Using a 2-mm cutoff, we visualized an effusion without the joint cupping maneuver at 2.5 mL and with the joint cupping technique at 1 mL. Mean effusion diameter increased on average 0.26 cm for the joint cupping maneuver as compared to without the maneuver. The effusion depth was statistically different at 2.5 and 7.5 mL (P < .05). Utilizing a joint cupping technique in combination with US is a valuable tool in assessing knee effusions, especially those of subclinical levels. Effusion measurements are complicated by uneven distribution of effusion fluid. A clinical joint cupping maneuver concentrates the fluid in one recess of the joint, increasing the likelihood of fluid detection using US. © 2013 Elsevier Inc. All rights reserved.

  9. Shear fracture of jointed steel plates of bolted joints under impact load

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.; Kobayashi, H.; Shin, H.-S.

    2013-07-01

    The present study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of bolted joints used in a car body, which contributes to crash simulations by CAE. We focus our attention on the shear fracture of the jointed steel plates of lap-bolted joints in the suspension of a car under impact load. Members of lap-bolted joints are modelled as a pair of steel plates connected by a bolt. One of the plates is a specimen subjected to plastic deformation and fracture and the other is a jig subjected to elastic deformation only. Three kinds of steel plate specimens are examined, i.e., a common steel plate with a tensile strength of 270 MPa and high tensile strength steel plates of 440 and 590 MPa used for cars. The impact shear test was performed using the split Hopkinson bar technique for tension impact, together with the static test using a universal testing machine INSTRON 5586. The behaviour of the shear stress and deformation up to rupture taking place in the joint was discussed. The obtained results suggest that a stress-based fracture criterion may be developed for the impact fracture of jointed steel plates of a lap-bolted joint.

  10. Dissimilar Brazed Joints Between Steel and Tungsten Carbide

    NASA Astrophysics Data System (ADS)

    Voiculescu, I.; Geanta, V.; Binchiciu, H.; Iovanas, D.; Stefanoiu, R.

    2017-06-01

    Brazing is a joining process used to obtain heterogeneous assemblies between different materials, such as steels, irons, non-ferrous metals, ceramics etc. Some application, like asphalt cutters, require quick solutions to obtain dissimilar joints at acceptable costs, given the very short period of operation of these parts. This paper presents some results obtained during the brazing of dissimilar joints between steel and tungsten carbide by using different types of Ag-Cu system filler materials alloyed with P and Sn. The brazing techniques used were oxygen-gas flame and induction joining. The brazing behaviour was analysed in cross sections by optical and electron microscopy. The metallographic analysis enhanced the adhesion features and the length of penetration in the joining gap. The melting range of the filler materials was measured using thermal analysis.

  11. Object-Part Attention Model for Fine-Grained Image Classification

    NASA Astrophysics Data System (ADS)

    Peng, Yuxin; He, Xiangteng; Zhao, Junjie

    2018-03-01

    Fine-grained image classification is to recognize hundreds of subcategories belonging to the same basic-level category, such as 200 subcategories belonging to the bird, which is highly challenging due to large variance in the same subcategory and small variance among different subcategories. Existing methods generally first locate the objects or parts and then discriminate which subcategory the image belongs to. However, they mainly have two limitations: (1) Relying on object or part annotations which are heavily labor consuming. (2) Ignoring the spatial relationships between the object and its parts as well as among these parts, both of which are significantly helpful for finding discriminative parts. Therefore, this paper proposes the object-part attention model (OPAM) for weakly supervised fine-grained image classification, and the main novelties are: (1) Object-part attention model integrates two level attentions: object-level attention localizes objects of images, and part-level attention selects discriminative parts of object. Both are jointly employed to learn multi-view and multi-scale features to enhance their mutual promotions. (2) Object-part spatial constraint model combines two spatial constraints: object spatial constraint ensures selected parts highly representative, and part spatial constraint eliminates redundancy and enhances discrimination of selected parts. Both are jointly employed to exploit the subtle and local differences for distinguishing the subcategories. Importantly, neither object nor part annotations are used in our proposed approach, which avoids the heavy labor consumption of labeling. Comparing with more than 10 state-of-the-art methods on 4 widely-used datasets, our OPAM approach achieves the best performance.

  12. Single and Multiple Object Tracking Using a Multi-Feature Joint Sparse Representation.

    PubMed

    Hu, Weiming; Li, Wei; Zhang, Xiaoqin; Maybank, Stephen

    2015-04-01

    In this paper, we propose a tracking algorithm based on a multi-feature joint sparse representation. The templates for the sparse representation can include pixel values, textures, and edges. In the multi-feature joint optimization, noise or occlusion is dealt with using a set of trivial templates. A sparse weight constraint is introduced to dynamically select the relevant templates from the full set of templates. A variance ratio measure is adopted to adaptively adjust the weights of different features. The multi-feature template set is updated adaptively. We further propose an algorithm for tracking multi-objects with occlusion handling based on the multi-feature joint sparse reconstruction. The observation model based on sparse reconstruction automatically focuses on the visible parts of an occluded object by using the information in the trivial templates. The multi-object tracking is simplified into a joint Bayesian inference. The experimental results show the superiority of our algorithm over several state-of-the-art tracking algorithms.

  13. 10 CFR 1021.216 - Procurement, financial assistance, and joint ventures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... competitive solicitations, unless the action is categorically excluded from preparation of an EA or EIS under...-source joint ventures, unless the action is categorically excluded from preparation of an EA or EIS under... environmental data and analyses as a discrete part of the offeror's proposal. DOE shall specify in its...

  14. Joint stability characteristics of the ankle complex after lateral ligamentous injury, part I: a laboratory comparison using arthrometric measurement.

    PubMed

    Kovaleski, John E; Heitman, Robert J; Gurchiek, Larry R; Hollis, J M; Liu, Wei; Pearsall, Albert W

    2014-01-01

    The mechanical property of stiffness may be important to investigating how lateral ankle ligament injury affects the behavior of the viscoelastic properties of the ankle complex. A better understanding of injury effects on tissue elastic characteristics in relation to joint laxity could be obtained from cadaveric study. To biomechanically determine the laxity and stiffness characteristics of the cadaver ankle complex before and after simulated injury to the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) during anterior drawer and inversion loading. Cross-sectional study. University research laboratory. Seven fresh-frozen cadaver ankle specimens. All ankles underwent loading before and after simulated lateral ankle injury using an ankle arthrometer. The dependent variables were anterior displacement, anterior end-range stiffness, inversion rotation, and inversion end-range stiffness. Isolated ATFL and combined ATFL and CFL sectioning resulted in increased anterior displacement but not end-range stiffness when compared with the intact ankle. With inversion loading, combined ATFL and CFL sectioning resulted in increased range of motion and decreased end-range stiffness when compared with the intact and ATFL-sectioned ankles. The absence of change in anterior end-range stiffness between the intact and ligament-deficient ankles indicated bony and other soft tissues functioned to maintain stiffness after pathologic joint displacement, whereas inversion loading of the CFL-deficient ankle after pathologic joint displacement indicated the ankle complex was less stiff when supported only by the secondary joint structures.

  15. Early, asymptomatic stage of degenerative joint disease in canine hip joints.

    PubMed

    Lust, G; Summers, B A

    1981-11-01

    The early stages of degenerative joint disease were investigated in coxofemoral joints from dogs with a hereditary predisposition to hip dysplasia. Alterations observed included mild nonsuppurative synovitis, increased volume of both synovial fluid and the ligamentum teres, and focal degenerative articular cartilage lesions. On radiologic examination, subluxation of the femoral head was seen, but only in the most severely affected joints. Synovial inflammation with increased synovial fluid and ligament volumes were indicators of early degenerative joint disease in dogs. These changes seemed to coincide with, or perhaps to precede, microscopic evidence for articular cartilage degeneration and occurred before radiologic abnormalities were detected.

  16. Joint Contact Stress

    PubMed Central

    Brand, Richard A

    2005-01-01

    A joint's normal mechanical history contributes to the maintenance of articular cartilage and underlying bone. Loading facilitates the flow of nutrients into cartilage and waste products away, and additionally provides the mechanical signals essential for normal cell and tissue maintenance. Deleteriously low or high contact stresses have been presumed to result in joint deterioration, and particular aspects of the mechanical environment may facilitate repair of damaged cartilage. For decades, investigators have explored static joint contact stresses (under some more or less arbitrary condition) as a surrogate of the relevant mechanical history. Contact stresses have been estimated in vitro in many joints and in a number of species, although only rarely in vivo. Despite a number of widely varying techniques (and spatial resolutions) to measure these contact stresses, reported ranges of static peak normal stresses are relatively similar from joint to joint across species, and in the range of 0.5 to 5.0 MPa. This suggests vertebrate diarthrodial joints have evolved to achieve similar mechanical design criteria. Available evidence also suggests some disorders of cartilage deterioration are associated with somewhat higher peak pressures ranging from 1-20 MPa, but overlapping the range of normal pressures. Some evidence and considerable logic suggests static contact stresses per se do not predict cartilage responses, but rather temporal aspects of the contact stress history. Static contact stresses may therefore not be a reasonable surrogate for biomechanical studies. Rather, temporal and spatial aspects of the loading history undoubtedly induce beneficial and deleterious biological responses. Finally, since all articular cartilage experiences similar stresses, the concept of a "weight-bearing" versus a "non-weight-bearing" joint seems flawed, and should be abandoned. PMID:16089079

  17. Rocket Motor Joint Construction Including Thermal Barrier

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor); Dunlap, Patrick H., Jr. (Inventor)

    2002-01-01

    A thermal barrier for extremely high temperature applications consists of a carbon fiber core and one or more layers of braided carbon fibers surrounding the core. The thermal barrier is preferably a large diameter ring, having a relatively small cross-section. The thermal barrier is particularly suited for use as part of a joint structure in solid rocket motor casings to protect low temperature elements such as the primary and secondary elastomeric O-ring seals therein from high temperature gases of the rocket motor. The thermal barrier exhibits adequate porosity to allow pressure to reach the radially outward disposed O-ring seals allowing them to seat and perform the primary sealing function. The thermal barrier is disposed in a cavity or groove in the casing joint, between the hot propulsion gases interior of the rocket motor and primary and secondary O-ring seals. The characteristics of the thermal barrier may be enhanced in different applications by the inclusion of certain compounds in the casing joint, by the inclusion of RTV sealant or similar materials at the site of the thermal barrier, and/or by the incorporation of a metal core or plurality of metal braids within the carbon braid in the thermal barrier structure.

  18. Rate dependent strengths of some solder joints

    NASA Astrophysics Data System (ADS)

    Williamson, D. M.; Field, J. E.; Palmer, S. J. P.; Siviour, C. R.

    2007-08-01

    The shear strengths of three lead-free solder joints have been measured over the range of loading rates 10-3 to ~105 mm min-1. Binary (SnAg), ternary (SnAgCu) and quaternary (Castin: SnAgCuSb) alloys have been compared to a conventional binary SnPb solder alloy. Results show that at loading rates from 10-3 to 102 mm min-1, all four materials exhibit a linear relationship between the shear strength and the loading rate when the data are plotted on a log-log plot. At the highest loading rate of 105 mm min-1, the strengths of the binary alloys were in agreement with extrapolations made from the lower loading rate data. In contrast, the strengths of the higher order alloys were found to be significantly lower than those predicted by extrapolation. This is explained by a change in failure mechanism on the part of the higher order alloys. Similar behaviour was found in measurements of the tensile strengths of solder joints using a novel high-rate loading tensile test. Optical and electron microscopy were used to examine the microstructures of interest in conjunction with energy dispersive x-ray analysis for elemental identification. The effect of artificial aging and reflow of the solder joints is also reported.

  19. Development of a Lubricant Therapy to Prevent Development of Osteoarthritis after Acute Injury of Synovial Joints

    DTIC Science & Technology

    2016-10-01

    test whether the pathological accumulation of a specific substance found in joint fluid following an injury mediated altered synovial fluid...joint injury contributes to the development of post-traumatic OA and is due, in part, to the pathological accumulation of a...studies, SF samples will be analyzed for the suspected pathological substance as well as lubrication function. 3.b.ii. Aim 2b

  20. Upper extremity interaction with a helicopter side airbag: injury criteria for dynamic hyperextension of the female elbow joint.

    PubMed

    Duma, Stefan M; Hansen, Gail A; Kennedy, Eric A; Rath, Amber L; McNally, Craig; Kemper, Andrew R; Smith, Eric P; Brolinson, P Gunnar; Stitzel, Joel D; Davis, Martin B; Bass, Cameron R; Brozoski, Frederick T; McEntire, B Joseph; Alem, Nabih M; Crowley, John S

    2004-11-01

    This paper describes a three part analysis to characterize the interaction between the female upper extremity and a helicopter cockpit side airbag system and to develop dynamic hyperextension injury criteria for the female elbow joint. Part I involved a series of 10 experiments with an original Army Black Hawk helicopter side airbag. A 5(th) percentile female Hybrid III instrumented upper extremity was used to demonstrate side airbag upper extremity loading. Two out of the 10 tests resulted in high elbow bending moments of 128 Nm and 144 Nm. Part II included dynamic hyperextension tests on 24 female cadaver elbow joints. The energy source was a drop tower utilizing a three-point bending configuration to apply elbow bending moments matching the previously conducted side airbag tests. Post-test necropsy showed that 16 of the 24 elbow joint tests resulted in injuries. Injury severity ranged from minor cartilage damage to more moderate joint dislocations and severe transverse fractures of the distal humerus. Peak elbow bending moments ranged from 42.4 Nm to 146.3 Nm. Peak bending moment proved to be a significant indicator of any elbow injury (p = 0.02) as well as elbow joint dislocation (p = 0.01). Logistic regression analyses were used to develop single and multiple variate injury risk functions. Using peak moment data for the entire test population, a 50% risk of obtaining any elbow injury was found at 56 Nm while a 50% risk of sustaining an elbow joint dislocation was found at 93 Nm for the female population. These results indicate that the peak elbow bending moments achieved in Part I are associated with a greater than 90% risk for elbow injury. Subsequently, the airbag was re-designed in an effort to mitigate this as well as the other upper extremity injury risks. Part III assessed the redesigned side airbag module to ensure injury risks had been reduced prior to implementing the new system. To facilitate this, 12 redesigned side airbag deployments were conducted

  1. Joint principles: Integrating behavioral health care into the patient-centered medical home.

    PubMed

    2014-06-01

    The Patient-centered Medical Home (PCMH) is an innovative, improved, and evolving approach to providing primary care that has gained broad acceptance in the United States. The Joint Principles of the PCMH, formulated and endorsed in February 2007, are sound and describe the ideal toward which we aspire. However, there is an element running implicitly through these joint principles that is difficult to achieve yet indispensable to the success of the entire PCMH concept. The incorporation of behavioral health care has not always been included as practices transform to accommodate to the PCMH ideals. This is an alarming development because the PCMH will be incomplete and ineffective without the full incorporation of this element, and retrofitting will be much more difficult than prospectively integrating into the original design of the PCMH. Therefore we offer a complementary set of joint principles that recognizes the centrality of behavioral health care as part of the PCMH. This document follows the order and language of the original joint principles while emphasizing what needs to be addressed to insure incorporation of the essential behavioral elements. It is intended to supplement and not replace the original Joint Principles document, which still stands.

  2. Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.

    2010-01-01

    Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.

  3. Gender differences exist in the hip joint moments of healthy older walkers.

    PubMed

    Boyer, Katherine A; Beaupre, Gary S; Andriacchi, Thomas P

    2008-12-05

    Gender differences in the incidence of symptomatic hip osteoarthritis (OA), changes in hip cartilage volume and hip joint space and rates hip arthroplasty of older people are reported in the literature. As the rate of progression of OA is in part mechanically modulated it is possible that this gender bias may be related to inherent differences (if they exist) in walking mechanics between older males and females. The purpose of this study was to examine potential mechanisms for gender differences in hip joint mechanics during walking by testing the hypotheses that females would exhibit higher hip flexion, adduction and internal rotation moments but not significantly greater normalized ground reaction forces (GRFs). Forty-two healthy subjects (21 male, 21 female), ages 50-79yr were recruited for gait analysis. In support of the hypotheses, greater external hip adduction and internal rotation along with hip extension moments were found for females compared to males after normalizing for body size for all self-selected walking speeds. Differences in walking style (kinematics) were the main determinants in the joint kinetic differences as no differences in the normalized GRFs were found. As external joint moments are surrogate measures of the joint contact forces, the results of this study suggest the hip joint stress for the female population is higher compared to male population. This is in favor of a hypothesis that the increased joint contact stress in a female population could contribute to a greater joint degeneration at the hip in females as compared with males.

  4. Modeling of Human Joint Structures.

    DTIC Science & Technology

    1982-09-01

    Acromioclavicular Joint .... ............. ... 20 Glenohumeral Joint .... ................ . 20 HIP JOINT .................. ...... 21 Iliofemoral Ligament...clavicle articulates with the manubrium of the sternum, and the acromioclavicular joint, where the clavicle articulates with the acromion process of the...the interclavicular ligament. Acromioclavicular Joint This articulation between the distal end of the clavicle and the acromion of the scapula is

  5. An interdigit signalling centre instructs coordinate phalanx-joint formation governed by 5′Hoxd–Gli3 antagonism

    PubMed Central

    Huang, Bau-Lin; Trofka, Anna; Furusawa, Aki; Norrie, Jacqueline L.; Rabinowitz, Adam H.; Vokes, Steven A.; Mark Taketo, M.; Zakany, Jozsef; Mackem, Susan

    2016-01-01

    The number of phalanges and joints are key features of digit ‘identity' and are central to limb functionality and evolutionary adaptation. Prior chick work indicated that digit phalanges and their associated joints arise in a different manner than the more sparsely jointed long bones, and their identity is regulated by differential signalling from adjacent interdigits. Currently, there is no genetic evidence for this model, and the molecular mechanisms governing digit joint specification remain poorly understood. Using genetic approaches in mouse, here we show that functional 5′Hoxd–Gli3 antagonism acts indirectly, through Bmp signalling from the interdigital mesenchyme, to regulate specification of joint progenitors, which arise in conjunction with phalangeal precursors at the digit tip. Phalanx number, although co-regulated, can be uncoupled from joint specification. We propose that 5′Hoxd genes and Gli3 are part of an interdigital signalling centre that sets net Bmp signalling levels from different interdigits to coordinately regulate phalanx and joint formation. PMID:27713395

  6. Prototype integration of the joint munitions assessment and planning model with the OSD threat methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lynn, R.Y.S.; Bolmarcich, J.J.

    The purpose of this Memorandum is to propose a prototype procedure which the Office of Munitions might employ to exercise, in a supportive joint fashion, two of its High Level Conventional Munitions Models, namely, the OSD Threat Methodology and the Joint Munitions Assessment and Planning (JMAP) model. The joint application of JMAP and the OSD Threat Methodology provides a tool to optimize munitions stockpiles. The remainder of this Memorandum comprises five parts. The first is a description of the structure and use of the OSD Threat Methodology. The second is a description of JMAP and its use. The third discussesmore » the concept of the joint application of JMAP and OSD Threat Methodology. The fourth displays sample output of the joint application. The fifth is a summary and epilogue. Finally, three appendices contain details of the formulation, data, and computer code.« less

  7. The Effect of Surface Irregularities on Wing Drag. II - Lap Joints. 2; Lap Joints

    NASA Technical Reports Server (NTRS)

    Hood, Manley J.

    1938-01-01

    Tests have been made in the NACA 8-foot high-speed wind tunnel of the drag caused by four types of lap joint. The tests were made on an airfoil of NACA 23012 section and 5-foot chord and covered in a range of speeds from 80 to 500 miles per hour and lift coefficients from 0 to 0.30. The increases in profile drag caused by representative arrangements of laps varied from 4 to 9%. When there were protruding rivet heads on the surface, the addition of laps increased the drag only slightly. Laps on the forward part of a wing increased the drag considerably more than those farther back.

  8. Joint Chiefs of Staff > Media

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Media News Videos Chairman's

  9. 12 CFR 533.11 - Other definitions and rules of construction used in this part.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., association, trust, joint venture, joint stock company, corporation, limited liability corporation, company... of construction used in this part. (a) Affiliate. Affiliate means— (1) Any company that controls, is controlled by, or is under common control with another company; and (2) For the purpose of determining...

  10. Comparison of 3-Dimensional Shoulder Complex Kinematics in Individuals With and Without Shoulder Pain, Part 1: Sternoclavicular, Acromioclavicular, and Scapulothoracic Joints

    PubMed Central

    LAWRENCE, REBEKAH L.; BRAMAN, JONATHAN P.; LAPRADE, ROBERT F.; LUDEWIG, PAULA M.

    2015-01-01

    STUDY DESIGN Cross-sectional. OBJECTIVES To compare sternoclavicular, acromioclavicular, and scapulothoracic joint motion between symptomatic and asymptomatic individuals during shoulder motion performed in 3 planes of humerothoracic elevation. BACKGROUND Differences in scapulothoracic kinematics are associated with shoulder pain. Several studies have measured these differences using surface sensors, but the results of this technique may be affected by skin-motion artifact. Furthermore, previous studies have not included the simultaneous measurement of sternoclavicular and acromioclavicular joint motion. METHODS Transcortical bone pins were inserted into the clavicle, scapula, and humerus of 12 asymptomatic and 10 symptomatic individuals for direct, bone-fixed tracking using electromagnetic sensors. Angular positions for the sternoclavicular, acromioclavicular, and scapulothoracic joints were measured during shoulder flexion, abduction, and scapular plane abduction. RESULTS Differences between groups were found for sternoclavicular and scapulothoracic joint positions. Symptomatic individuals consistently demonstrated less sternoclavicular posterior rotation, regardless of angle, phase, or plane of shoulder motion. Symptomatic individuals also demonstrated less scapulothoracic upward rotation at 30° and 60° of humerothoracic elevation during shoulder abduction and scapular plane abduction. CONCLUSION The results of this study show that differences in shoulder complex kinematics exist between symptomatic and asymptomatic individuals. However, the magnitude of these differences was small, and the resulting clinical implications are not yet fully understood. The biomechanical coupling of the sternoclavicular and acromioclavicular joints requires further research to better understand scapulothoracic movement deviations and to improve manual therapy and exercise-based physical therapy interventions. PMID:25103135

  11. Experimental and numerical evaluation of the fatigue behaviour in a welded joint

    NASA Astrophysics Data System (ADS)

    Almaguer, P.; Estrada, R.

    2014-07-01

    Welded joints are an important part in structures. For this reason, it is always necessary to know the behaviour of them under cyclic loads. In this paper a S - N curve of a butt welded joint of the AISI 1015 steel and Cuban manufacturing E6013 electrode is showed. Fatigue tests were made in an universal testing machine MTS810. The stress ratio used in the test was 0,1. Flaws in the fatigue specimens were characterized by means of optical and scanning electron microscopy. SolidWorks 2013 software was used to modeling the specimens geometry, while to simulate the fatigue behaviour Simulation was used. The joint fatigue limit is 178 MPa, and a cut point at 2 039 093 cycles. Some points of the simulations are inside of the 95% confidence band.

  12. T2 Mapping of the Sacroiliac Joints With 3-T MRI: A Preliminary Study.

    PubMed

    Lefebvre, Guillaume; Bergère, Antonin; Rafei, Mazen El; Duhamel, Alain; Teixeira, Pedro; Cotten, Anne

    2017-08-01

    The objective of this study was to assess the feasibility of T2 relaxation time measurements of the sacroiliac joints. The sacroiliac joints of 40 patients were imaged by 3-T MRI using an oblique axial multislice multiecho spin-echo T2-weighted sequence. Manual plotting and automatic subdivision of ROIs allowed us to obtain T2 values for up to 48 different areas per patient (posterior and anterior parts, sacral, intermediate, and iliac parts). Intraand interobserver reproducibility of T2 values were calculated after independent assessment by two musculoskeletal radiologists. A total of 1656 measurement sites could be analyzed. Mean (± SD) T2 values were 40.6 ± 6.7 ms and 41.2 ± 6.3 ms for observer 1 and 39.9 ± 6.6 ms for observer 2. The intraobserver intraclass correlation coefficient was 0.72 (95% CI, 0.70-0.74), and the interobserver intraclass correlation coefficient was 0.71 (95% CI, 0.68-0.72). Our study shows the feasibility of T2 relaxation time measurements at the sacroiliac joints.

  13. Experimental joint immobilization in guinea pigs. Effects on the knee joint

    NASA Technical Reports Server (NTRS)

    Marcondesdesouza, J. P.; Machado, F. F.; Sesso, A.; Valeri, V.

    1980-01-01

    In young and adult guinea pigs, the aftermath experimentally induced by the immobilization of the knee joint in hyperextended forced position was studied. Joint immobilization which varied from one to nine weeks was attained by plaster. Eighty knee joints were examined macro and microscopically. Findings included: (1) muscular hypotrophy and joint stiffness in all animals, directly proportional to the length of immobilization; (2) haemoarthrosis in the first week; (3) intra-articular fibrous tissue proliferation ending up with fibrous ankylosis; (4) hyaline articular cartilage erosions; (5) various degrees of destructive menisci changes. A tentative explanation of the fibrous tissue proliferation and of the cartilage changes is offered.

  14. Comparison of 3-Dimensional Shoulder Complex Kinematics in Individuals With and Without Shoulder Pain, Part 2: Glenohumeral Joint

    PubMed Central

    LAWRENCE, REBEKAH L.; BRAMAN, JONATHAN P.; STAKER, JUSTIN L.; LAPRADE, ROBERT F.; LUDEWIG, PAULA M.

    2015-01-01

    STUDY DESIGN Cross-sectional. OBJECTIVES To compare differences in glenohumeral joint angular motion and linear translations between symptomatic and asymptomatic individuals during shoulder motion performed in 3 planes of humerothoracic elevation. BACKGROUND Numerous clinical theories have linked abnormal glenohumeral kinematics, including decreased glenohumeral external rotation and increased superior translation, to individuals with shoulder pain and impingement diagnoses. However, relatively few studies have investigated glenohumeral joint angular motion and linear translations in this population. METHODS Transcortical bone pins were inserted into the scapula and humerus of 12 a symptomatic and 10 symptomatic participants for direct bone-fixed tracking using electromagnetic sensors. Glenohumeral joint angular positions and linear translations were calculated during active shoulder flexion, abduction, and scapular plane abduction. RESULTS Differences between groups in angular positions were limited to glenohumeral elevation, coinciding with a reduction in scapulothoracic upward rotation. Symptomatic participants demonstrated 1.4 mm more anterior glenohumeral translation between 90° and 120° of shoulder flexion and an average of 1 mm more inferior glenohumeral translation throughout shoulder abduction. CONCLUSION Differences in glenohumeral kinematics exist between symptomatic and a symptomatic individuals. The clinical implications of these differences are not yet understood, and more research is needed to understand the relationship between abnormal kinematics, shoulder pain, and pathoanatomy. PMID:25103132

  15. Deficiency of Hyaluronan Synthase 1 (Has1) Results in Chronic Joint Inflammation and Widespread Intra-Articular Fibrosis in a Murine Model of Knee Joint Cartilage Damage

    PubMed Central

    Chan, Deva D.; Xiao, Wenfeng; Li, Jun; de la Motte, Carol A.; Sandy, John D.; Plaas, Anna

    2015-01-01

    Objective Articular cartilage defects commonly result from traumatic injury and predispose to degenerative joint diseases. To test the hypothesis that aberrant healing responses and chronic inflammation lead to osteoarthritis, we examined spatiotemporal changes in joint tissues after cartilage injury in murine knees. Since intra-articular injection of hyaluronan (HA) can attenuate injury-induced osteoarthritis in wild-type (WT) mice, we investigated a role for HA in the response to cartilage injury in mice lacking HA synthase 1 (Has1−/−). Design Femoral groove cartilage of WT and Has1−/− mice was debrided to generate a non-bleeding wound. Macroscopic imaging, histology, and gene expression were used to evaluate naïve, sham-operated, and injured joints. Results Acute responses (1–2 weeks) in injured joints from WT mice included synovial hyperplasia with HA deposition and joint-wide increases in expression of genes associated with inflammation, fibrosis, and extracellular matrix (ECM) production. By 4 weeks, some resurfacing of damaged cartilage occurred, and early cell responses were normalized. Cartilage damage in Has1−/− mice also induced early responses; however, at 4 weeks, inflammation and fibrosis genes remained elevated with widespread cartilage degeneration and fibrotic scarring in the synovium and joint capsule. Conclusions We conclude that the ineffective repair of injured cartilage in Has1−/− joints can be at least partly explained by the markedly enhanced expression of particular genes in pathways linked to ECM turnover, IL-17/IL-6 cytokine signaling, and apoptosis. Notably, Has1 ablation does not alter gross HA content in the ECM, suggesting that HAS1 has a unique function in the metabolism of inflammatory HA matrices. PMID:26521733

  16. Medicare Reimbursement for Total Joint Arthroplasty: The Driving Forces.

    PubMed

    Padegimas, Eric M; Verma, Kushagra; Zmistowski, Benjamin; Rothman, Richard H; Purtill, James J; Howley, Michael

    2016-06-15

    Total joint arthroplasty is a large and growing part of the U.S. Medicare budget, drawing attention to how much providers are paid for their services. The purpose of this study was to examine the variables that affect total joint arthroplasty reimbursement. Along with standard economic variables, we include unique health-care variables. Given the focus on value in the Affordable Care Act, the model examines the relationship of the quality of care to total joint arthroplasty reimbursement. We hoped to find that reimbursement patterns reward quality and reflect standard economic principles. Multivariable regression was performed to identify variables that correlate with Medicare reimbursement for total joint arthroplasty. Inpatient charge or reimbursement data on Medicare reimbursements were available for 2,750 hospitals with at least 10 discharges for uncomplicated total joint arthroplasty from the Centers for Medicare & Medicaid Services (CMS) for fiscal year 2011. Reimbursement variability was examined by using the Dartmouth Atlas to group institutions into hospital referral regions and hospital service areas. Independent variables were taken from the Dartmouth Atlas, CMS, the WWAMI (Washington, Wyoming, Alaska, Montana, Idaho) Rural Health Research Center, and the United States Census. There were 427,207 total joint arthroplasties identified, with a weighted mean reimbursement of $14,324.84 (range, $9,103 to $38,686). Nationally, the coefficient of variation for reimbursements was 0.19. The regression model accounted for 52.5% of reimbursement variation among providers. The total joint arthroplasty provider volume (p < 0.001) and patient satisfaction (p < 0.001) were negatively correlated with reimbursement. Government ownership of a hospital (p < 0.001) and higher Medicare costs (p < 0.001) correlated positively with reimbursement. Medicare reimbursements for total joint arthroplasty are highly variable. Greater reimbursement was associated with lower patient

  17. Understanding the Impact of Expertise in Joint and Solo-Improvisation.

    PubMed

    Issartel, Johann; Gueugnon, Mathieu; Marin, Ludovic

    2017-01-01

    Joint-improvisation is not only an open-ended creative action that two or more people perform together in the context of an artistic performance (e.g., theatre, music or dance). Joint-improvisation also takes place in daily life activities when humans take part in collective performance such as toddlers at play or adults engaged in a conversation. In the context of this article, joint-improvisation has been looked at from a social motor coordination perspective. In the literature, the nature of the social motor coordination characteristics of joint-improvisation for either the creative aspect or daily life features of this motor performance remains unclear. Additionally, both solo-improvisation and joint-improvisation need to be studied conjointly to establish the influence of the social element of improvisation in the emergence of multi-agent motor coordination. In order to better understand those two types of improvisation, we compared three level of expertise - novice, intermediate and professional in dance improvisation to identify movement characteristics for each of the groups. Pairs of the same level were asked to improvise together. Each individual was also asked to perform an improvisation on his/her own. We found that each of the three groups present specific movement organization with movement complexity increasing with the level of expertise. Experts performed shorter movement duration in conjunction with an increase range of movement. The direct comparison of individual and paired Conditions highlighted that the joint-improvisation reduced the complexity of the movement organization and those for all three levels while maintaining the differences between the groups. This direct comparison amongst those three distinct groups provides an original insight onto the nature of movement patterns in joint-improvisation situation. Overall, it reveals the role of both individual and collective properties in the emergence of social coordination.

  18. Understanding the Impact of Expertise in Joint and Solo-Improvisation

    PubMed Central

    Issartel, Johann; Gueugnon, Mathieu; Marin, Ludovic

    2017-01-01

    Joint-improvisation is not only an open-ended creative action that two or more people perform together in the context of an artistic performance (e.g., theatre, music or dance). Joint-improvisation also takes place in daily life activities when humans take part in collective performance such as toddlers at play or adults engaged in a conversation. In the context of this article, joint-improvisation has been looked at from a social motor coordination perspective. In the literature, the nature of the social motor coordination characteristics of joint-improvisation for either the creative aspect or daily life features of this motor performance remains unclear. Additionally, both solo-improvisation and joint-improvisation need to be studied conjointly to establish the influence of the social element of improvisation in the emergence of multi-agent motor coordination. In order to better understand those two types of improvisation, we compared three level of expertise – novice, intermediate and professional in dance improvisation to identify movement characteristics for each of the groups. Pairs of the same level were asked to improvise together. Each individual was also asked to perform an improvisation on his/her own. We found that each of the three groups present specific movement organization with movement complexity increasing with the level of expertise. Experts performed shorter movement duration in conjunction with an increase range of movement. The direct comparison of individual and paired Conditions highlighted that the joint-improvisation reduced the complexity of the movement organization and those for all three levels while maintaining the differences between the groups. This direct comparison amongst those three distinct groups provides an original insight onto the nature of movement patterns in joint-improvisation situation. Overall, it reveals the role of both individual and collective properties in the emergence of social coordination. PMID:28713301

  19. 12 CFR 35.11 - Other definitions and rules of construction used in this part.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...” is any partnership, association, trust, joint venture, joint stock company, corporation, limited... construction used in this part. (a) Affiliate. “Affiliate” means— (1) Any company that controls, is controlled by, or is under common control with another company; and (2) For the purpose of determining whether...

  20. 12 CFR 346.11 - Other definitions and rules of construction used in this part.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...” is any partnership, association, trust, joint venture, joint stock company, corporation, limited... definitions and rules of construction used in this part. (a) Affiliate. “Affiliate” means— (1) Any company that controls, is controlled by, or is under common control with another company; and (2) For the...

  1. 24 CFR 943.150 - What procurement standards apply to a PHA's joint venture partner?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false What procurement standards apply to... Subsidiaries, Affiliates, Joint Ventures in Public Housing § 943.150 What procurement standards apply to a PHA..., accordingly, is not required to comply with part 84 or part 85 of this title in its procurement of goods and...

  2. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    NASA Astrophysics Data System (ADS)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  3. The Joint Master Operational Planner

    DTIC Science & Technology

    2016-04-04

    Daniel H. Hibner, United States Army Joint Forces Staff College Joint Advanced Warfighting School 7800 Hampton Blvd. Norfolk, VA 23511-1702 Approved...Operational Art. Unclass Unclass Unclass Unclassified Unlimited 66 757-443-6301 NATIONAL DEFENSE UNIVERSITY JOINT FORCES STAFF COLLEGE JOINT ADVANCED...of this paper reflect my own personal views and are not necessarily endorsed by the Joint Forces Staff College or the department of Defense. Thesis

  4. An effective framework for finding similar cases of dengue from audio and text data using domain thesaurus and case base reasoning

    NASA Astrophysics Data System (ADS)

    Sandhu, Rajinder; Kaur, Jaspreet; Thapar, Vivek

    2018-02-01

    Dengue, also known as break-bone fever, is a tropical disease transmitted by mosquitoes. If the similarity between dengue infected users can be identified, it can help government's health agencies to manage the outbreak more effectively. To find similarity between cases affected by Dengue, user's personal and health information are the two fundamental requirements. Identification of similar symptoms, causes, effects, predictions and treatment procedures, is important. In this paper, an effective framework is proposed which finds similar patients suffering from dengue using keyword aware domain thesaurus and case base reasoning method. This paper focuses on the use of ontology dependent domain thesaurus technique to extract relevant keywords and then build cases with the help of case base reasoning method. Similar cases can be shared with users, nearby hospitals and health organizations to manage the problem more adequately. Two million case bases were generated to test the proposed similarity method. Experimental evaluations of proposed framework resulted in high accuracy and low error rate for finding similar cases of dengue as compared to UPCC and IPCC algorithms. The framework developed in this paper is for dengue but can easily be extended to other domains also.

  5. Does Talocrural Joint-Thrust Manipulation Improve Outcomes After Inversion Ankle Sprain?

    PubMed

    Krueger, Brett; Becker, Laura; Leemkuil, Greta; Durall, Christopher

    2015-08-01

    Clinical Scenario: Ankle sprains account for roughly 10% of sport-related injuries in the active population. The majority of these injuries occur from excessive ankle inversion, leading to lateral ligamentous injury. In addition to pain and swelling, limitations in ankle range of motion (ROM) and self-reported function are common findings. These limitations are thought to be due in part to loss of mobility in the talocrural joint. Accordingly, some investigators have reported using high-velocity, low-amplitude thrust-manipulation techniques directed at the talocrural joint to address deficits in dorsiflexion (DF) ROM and function. This review was conducted to ascertain the impact of talocrural joint-thrust manipulation (TJM) on DF ROM, self-reported function, and pain in patients with a history of ankle sprain. Focused Clinical Question: In patients with a history of inversion ankle sprain, does TJM improve outcomes in DF ROM, self-reported function, and/or pain?

  6. Improving Therapeutic Relationships: Joint Crisis Planning for Individuals With Psychotic Disorders.

    PubMed

    Farrelly, Simone; Lester, Helen; Rose, Diana; Birchwood, Max; Marshall, Max; Waheed, Waquas; Henderson, R Claire; Szmukler, George; Thornicroft, Graham

    2015-12-01

    Outcomes for individuals with psychosis remain far from acceptable. Recently, prominent psychiatrists have called for an improved understanding of the impact of social contexts, and how social contexts might influence the development and maintenance of mental health problems. A key social context for individuals with psychosis is the therapeutic relationship. As part of a trial of joint crisis planning in England, this qualitative study aimed to determine the mechanism through which joint crisis planning might affect the therapeutic relationship. Results suggest that routine processes in mental health care are affected by policy and organizational requirements for risk mitigation-aspects that undermine person-centered approaches. In contrast, strong therapeutic relationships are characterized by individualized care and reliable and respectful treatment. The Joint Crisis Plan intervention partially succeeded in reducing contextual influences on routine role enactments, facilitating the demonstration of respect and improving the therapeutic relationship. © The Author(s) 2015.

  7. Cellular Pressure-Actuated Joint

    NASA Technical Reports Server (NTRS)

    McGuire, John R.

    2003-01-01

    A modification of a pressure-actuated joint has been proposed to improve its pressure actuation in such a manner as to reduce the potential for leakage of the pressurizing fluid. The specific joint for which the modification is proposed is a field joint in a reusable solid-fuel rocket motor (RSRM), in which the pressurizing fluid is a mixture of hot combustion gases. The proposed modification could also be applicable to other pressure-actuated joints of similar configuration.

  8. Mechanics of Suture Joints

    NASA Astrophysics Data System (ADS)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  9. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    PubMed

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  10. The Interface of Mechanics and Nociception in Joint Pathophysiology: Insights From the Facet and Temporomandibular Joints

    PubMed Central

    Sperry, Megan M.; Ita, Meagan E.; Kartha, Sonia; Zhang, Sijia; Yu, Ya-Hsin; Winkelstein, Beth

    2017-01-01

    Chronic joint pain is a widespread problem that frequently occurs with aging and trauma. Pain occurs most often in synovial joints, the body's load bearing joints. The mechanical and molecular mechanisms contributing to synovial joint pain are reviewed using two examples, the cervical spinal facet joints and the temporomandibular joint (TMJ). Although much work has focused on the macroscale mechanics of joints in health and disease, the combined influence of tissue mechanics, molecular processes, and nociception in joint pain has only recently become a focus. Trauma and repeated loading can induce structural and biochemical changes in joints, altering their microenvironment and modifying the biomechanics of their constitutive tissues, which themselves are innervated. Peripheral pain sensors can become activated in response to changes in the joint microenvironment and relay pain signals to the spinal cord and brain where pain is processed and perceived. In some cases, pain circuitry is permanently changed, which may be a potential mechanism for sustained joint pain. However, it is most likely that alterations in both the joint microenvironment and the central nervous system (CNS) contribute to chronic pain. As such, the challenge of treating joint pain and degeneration is temporally and spatially complicated. This review summarizes anatomy, physiology, and pathophysiology of these joints and the sensory pain relays. Pain pathways are postulated to be sensitized by many factors, including degeneration and biochemical priming, with effects on thresholds for mechanical injury and/or dysfunction. Initiators of joint pain are discussed in the context of clinical challenges including the diagnosis and treatment of pain. PMID:28056123

  11. Strength Variation of Parachute Joints

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    A parachute joint is defined as a location where a component is sewn or connected to another component. During the design and developmental phase of a parachute system, the joints for each structural component are isolated and tested through a process called seam and joint testing. The objective of seam and joint testing is to determine the degradation on a single component due to interaction with other components; this data is then used when calculating the margin of safety for that component. During the engineering developmental phase of CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module, testing was completed for every joint of the six subsystems: the four parachutes (main, drogue, pilot, and FBCP [forward bay cover parachute]), the retention release bridle, and the retention panels. The number of joint tests for these subsystems totaled 92, which provides a plethora of data and results for further analysis. In this paper, the data and results of these seam and joint tests are examined to determine the effects, if any, of different operators and sewing machines on the strength of parachute joints. Other variables are also studied to determine their effect on joint strength, such as joint complexity, joint strength magnitude, material type, and material construction. Findings reveal that an optimally-run seam and joint test program could result in an increased understanding of the structure of the parachute; this should lead to a parachute built with optimal components, potentially saving system weight and volume.

  12. FBG in PVC foils for monitoring the knee joint movement during the rehabilitation process.

    PubMed

    Rocha, R P; Silva, A F; Carmo, J P; Correia, J H

    2011-01-01

    This paper presents a sensing electronic-free wearable solution for monitoring the body kinematics. The measuring of the knee movements, flexion and extension, with the corresponding joint acting as the rotation axis is shown as working principle. The proposed sensing system is based on a single optical Fiber-Bragg Grating (FBG) with a resonance wavelength of 1547.76 nm. The optical fiber with the FBG is placed inside a new polymeric foil composed by three flexible layers which facilitates its placement in the anatomic parts under investigation while maintaining full sensing capabilities. The way the device is placed in the specific body part to be measured enables the clear detection of the movements in respect to the joint. The proposed solution was tested using a prototype that was built to evaluate the device under different condition tests and also to assess the system's consistency. The designed and fabricated system demonstrates clear advantages in medical fields like physical therapy applications as optical fiber is not affected by electromagnetic interference nor does the system needs complex and expensive electronic systems and mechanical parts. Another advantage is the possibility to measure, record and evaluate specific mechanical parameters of the limbs' motion. Patients with bone, muscular and joint related health conditions, as well as athletes, are within the most important end-user applications.

  13. Lower extremity joint kinetics and lumbar curvature during squat and stoop lifting

    PubMed Central

    Hwang, Seonhong; Kim, Youngeun; Kim, Youngho

    2009-01-01

    Background In this study, kinematics and kinetics of the lower extremity joint and the lumbar lordosis during two different symmetrical lifting techniques(squat and stoop) were examined using the three-dimensional motion analysis. Methods Twenty-six young male volunteers were selected for the subjects in this study. While they lifted boxes weighing 5, 10 and 15 kg by both squat and stoop lifting techniques, their motions were captured and analyzed using the 3D motion analysis system which was synchronized with two forceplates and the electromyographic system. Joint kinematics was determined by the forty-three reflective markers which were attached on the anatomical locations based on the VICON Plug-in-Gait marker placement protocol. Joint kinetics was analyzed by using the inverse dynamics. Paired t-test and Kruskal-Wallis test was used to compare the differences of variables between two techniques, and among three different weights. Correlation coefficient was calculated to explain the role of lower limb joint motion in relation to the lumbar lordosis. Results There were not significant differences in maximum lumbar joint moments between two techniques. The hip and ankle contributed the most part of the support moment during squat lifting, and the knee flexion moment played an important role in stoop lifting. The hip, ankle and lumbar joints generated power and only the knee joint absorbed power in the squat lifting. The knee and ankle joints absorbed power, the hip and lumbar joints generated power in the stoop lifting. The bi-articular antagonist muscles' co-contraction around the knee joint during the squat lifting and the eccentric co-contraction of the gastrocnemius and the biceps femoris were found important for maintaining the straight leg during the stoop lifting. At the time of lordotic curvature appearance in the squat lifting, there were significant correlations in all three lower extremity joint moments with the lumbar joint. Differently, only the hip

  14. Lower extremity joint kinetics and lumbar curvature during squat and stoop lifting.

    PubMed

    Hwang, Seonhong; Kim, Youngeun; Kim, Youngho

    2009-02-02

    In this study, kinematics and kinetics of the lower extremity joint and the lumbar lordosis during two different symmetrical lifting techniques(squat and stoop) were examined using the three-dimensional motion analysis. Twenty-six young male volunteers were selected for the subjects in this study. While they lifted boxes weighing 5, 10 and 15 kg by both squat and stoop lifting techniques, their motions were captured and analyzed using the 3D motion analysis system which was synchronized with two forceplates and the electromyographic system. Joint kinematics was determined by the forty-three reflective markers which were attached on the anatomical locations based on the VICON Plug-in-Gait marker placement protocol. Joint kinetics was analyzed by using the inverse dynamics. Paired t-test and Kruskal-Wallis test was used to compare the differences of variables between two techniques, and among three different weights. Correlation coefficient was calculated to explain the role of lower limb joint motion in relation to the lumbar lordosis. There were not significant differences in maximum lumbar joint moments between two techniques. The hip and ankle contributed the most part of the support moment during squat lifting, and the knee flexion moment played an important role in stoop lifting. The hip, ankle and lumbar joints generated power and only the knee joint absorbed power in the squat lifting. The knee and ankle joints absorbed power, the hip and lumbar joints generated power in the stoop lifting. The bi-articular antagonist muscles' co-contraction around the knee joint during the squat lifting and the eccentric co-contraction of the gastrocnemius and the biceps femoris were found important for maintaining the straight leg during the stoop lifting. At the time of lordotic curvature appearance in the squat lifting, there were significant correlations in all three lower extremity joint moments with the lumbar joint. Differently, only the hip moment had significant

  15. Joint Enrollment Report, 2014

    ERIC Educational Resources Information Center

    Iowa Department of Education, 2014

    2014-01-01

    The Iowa Department of Education collects information on joint enrollment in Iowa's 15 community colleges. Jointly enrolled students are high school students enrolled in community college credit coursework. Most jointly enrolled students enroll through Senior Year Plus (SYP) programs such as Postsecondary Enrollment Options (PSEO) and concurrent…

  16. Joint Enrollment Report, 2015

    ERIC Educational Resources Information Center

    Iowa Department of Education, 2015

    2015-01-01

    The Iowa Department of Education collects information on joint enrollment from Iowa's 15 community colleges. Jointly enrolled students are high school students enrolled in community college credit coursework. Most jointly enrolled students enroll through Senior Year Plus programs such as Postsecondary Enrollment Options (PSEO) and concurrent…

  17. Preclinical Animal Models for Temporomandibular Joint Tissue Engineering.

    PubMed

    Almarza, Alejandro J; Brown, Bryan N; Arzi, Boaz; Ângelo, David Faustino; Chung, William; Badylak, Stephen F; Detamore, Michael

    2018-06-01

    There is a paucity of in vivo studies that investigate the safety and efficacy of temporomandibular joint (TMJ) tissue regeneration approaches, in part due to the lack of established animal models. Review of disease models for study of TMJ is presented herein with an attempt to identify relevant preclinical animal models for TMJ tissue engineering, with emphasis on the disc and condyle. Although degenerative joint disease models have been mainly performed on mice, rats, and rabbits, preclinical regeneration approaches must employ larger animal species. There remains controversy regarding the preferred choice of larger animal models between the farm pig, minipig, goat, sheep, and dog. The advantages of the pig and minipig include their well characterized anatomy, physiology, and tissue properties. The advantages of the sheep and goat are their easier surgical access, low cost per animal, and its high tissue availability. The advantage of the dog is that the joint space is confined, so migration of interpositional devices should be less likely. However, each species has limitations as well. For example, the farm pig has continuous growth until about 18 months of age, and difficult surgical access due to the zygomatic arch covering the lateral aspect of joint. The minipig is not widely available and somewhat costly. The sheep and the goat are herbivores, and their TMJs mainly function in translation. The dog is a carnivore, and the TMJ is a hinge joint that can only rotate. Although no species provides the gold standard for all preclinical TMJ tissue engineering approaches, the goat and sheep have emerged as the leading options, with the minipig as the choice when cost is less of a limitation; and with the dog and farm pig serving as acceptable alternatives. Finally, naturally occurring TMJ disorders in domestic species may be harnessed on a preclinical trial basis as a clinically relevant platform for translation.

  18. Migrating lumbar facet joint cysts.

    PubMed

    Palmieri, Francesco; Cassar-Pullicino, Victor N; Lalam, Radhesh K; Tins, Bernhard J; Tyrrell, Prudencia N M; McCall, Iain W

    2006-04-01

    The majority of lumbar facet joint cysts (LFJCs) are located in the spinal canal, on the medial aspect of the facet joint with characteristic diagnostic features. When they migrate away from the joint of origin, they cause diagnostic problems. In a 7-year period we examined by computed tomography (CT) and magnetic resonance (MR) imaging five unusual cases of facet joint cysts which migrated from the facet joint of origin. Three LFJCs were identified in the right S1 foramen, one in the right L5-S1 neural foramen and one in the left erector spinae and multifidus muscles between the levels of L2-L4 spinous process. Awareness that spinal lesions identified at MRI and CT could be due to migrating facet joint cyst requires a high level of suspicion. The identification of the appositional contact of the cyst and the facet joint needs to be actively sought in the presence of degenerative facet joints.

  19. Joint Chiefs of Staff > Directorates > J7 | Joint Force Development

    Science.gov Websites

    development: Doctrine, Education, Concept Development & Experimentation, Training, Exercises and Lessons Coalition Partners. Joint Education Develop policies governing officer and enlisted Joint Professional Military Education (JPME), and the National Defense University. Direct JPME educational advisory group and

  20. Joint Mobilization Enhances Mechanisms of Conditioned Pain Modulation in Individuals With Osteoarthritis of the Knee.

    PubMed

    Courtney, Carol A; Steffen, Alana D; Fernández-de-Las-Peñas, César; Kim, John; Chmell, Samuel J

    2016-03-01

    An experimental laboratory study with a repeated-measures crossover design. Treatment effects of joint mobilization may occur in part by decreasing excitability of central nociceptive pathways. Impaired conditioned pain modulation (CPM) has been found experimentally in persons with knee and hip osteoarthritis, indicating impaired inhibition of central nociceptive pathways. We hypothesized increased effectiveness of CPM following application of joint mobilization, determined via measures of deep tissue hyperalgesia. To examine the effect of joint mobilization on impaired CPM. An examination of 40 individuals with moderate/severe knee osteoarthritis identified 29 (73%) with impaired CPM. The subjects were randomized to receive 6 minutes of knee joint mobilization (intervention) or manual cutaneous input only, 1 week apart. Deep tissue hyperalgesia was examined via pressure pain thresholds bilaterally at the knee medial joint line and the hand at baseline, postintervention, and post-CPM testing. Further, vibration perception threshold was measured at the medial knee epicondyle at baseline and post-CPM testing. Joint mobilization, but not cutaneous input intervention, resulted in a global increase in pressure pain threshold, indicated by diminished hyperalgesic responses to pressure stimulus. Further, CPM was significantly enhanced following joint mobilization. Diminished baseline vibration perception threshold acuity was enhanced following joint mobilization at the knee that received intervention, but not at the contralateral knee. Resting pain was also significantly lower following the joint intervention. Conditioned pain modulation was enhanced following joint mobilization, demonstrated by a global decrease in deep tissue pressure sensitivity. Joint mobilization may act via enhancement of descending pain mechanisms in patients with painful knee osteoarthritis.

  1. Effects of joints in truss structures

    NASA Technical Reports Server (NTRS)

    Ikegami, R.

    1988-01-01

    The response of truss-type structures for future space applications, such as Large Deployable Reflector (LDR), will be directly affected by joint performance. Some of the objectives of research at BAC were to characterize structural joints, establish analytical approaches that incorporate joint characteristics, and experimentally establish the validity of the analytical approaches. The test approach to characterize joints for both erectable and deployable-type structures was based upon a Force State Mapping Technique. The approach pictorially shows how the nonlinear joint results can be used for equivalent linear analysis. Testing of the Space Station joints developed at LaRC (a hinged joint at 2 Hz and a clevis joint at 2 Hz) successfully revealed the nonlinear characteristics of the joints. The Space Station joints were effectively linear when loaded to plus or minus 500 pounds with a corresponding displacement of about plus or minus 0.0015 inch. It was indicated that good linear joints exist which are compatible with errected structures, but that difficulty may be encountered if nonlinear-type joints are incorporated in the structure.

  2. Culture - joint fluid

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003742.htm Culture - joint fluid To use the sharing features on this page, please enable JavaScript. Joint fluid culture is a laboratory test to detect infection-causing ...

  3. Joint Chiefs of Staff > About > Joint Staff Inspector General

    Science.gov Websites

    DD Form 2949, Joint Inspector General Action Request (available at the link below). However, if you action if you intentionally make false statements. When you sign a DD Form 2949, you are signing a . DD Form 2949, Joint Inspector General Action Request Click here to expand content Click here to

  4. Cardiovascular Aspects of Aging (Part 1 of 2).

    ERIC Educational Resources Information Center

    Van Camp, Steven P.; Boyer, John L.

    1989-01-01

    Reviews cardiovascular changes occurring during the aging process and the trainability of older persons. Although cardiovascular changes are part of life, activity levels need not decrease. Beneficial aspects of exercise include improvements in muscle strength, joint mobility, flexibility, coordination, and weight control. (SM)

  5. Ceramic joints

    DOEpatents

    Miller, Bradley J.; Patten, Jr., Donald O.

    1991-01-01

    Butt joints between materials having different coefficients of thermal expansion are prepared having a reduced probability of failure of stress facture. This is accomplished by narrowing/tapering the material having the lower coefficient of thermal expansion in a direction away from the joint interface and not joining the narrow-tapered surface to the material having the higher coefficient of thermal expansion.

  6. Sacroiliac joint dysfunction.

    PubMed

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  7. Cytokine mRNA expression in synovial fluid of affected and contralateral stifle joints and the left shoulder joint in dogs with unilateral disease of the stifle joint.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Duchateau, Luc; Cox, Eric

    2007-09-01

    To examine mRNA expression of cytokines in synovial fluid (SF) cells from dogs with cranial cruciate ligament (CrCL) rupture and medial patellar luxation (MPL) and determine mRNA expression for 3 joints (affected stifle, unaffected contralateral stifle, and left shoulder joints) in dogs with unilateral CrCL rupture. 29 stifle joints with CrCL rupture (29 dogs), 8 stifle joints with MPL (7 dogs), and 24 normal stifle joints (16 clinically normal dogs). Immediately before reconstructive surgery, SF was aspirated from the cruciate-deficient stifle joint or stifle joint with MPL. Fourteen of 29 dogs had unilateral CrCL rupture; SF was also aspirated from the unaffected contralateral stifle joint and left shoulder joint. Those 14 dogs were examined 6 and 12 months after reconstructive surgery. Total RNA was extracted from SF cells and reverse transcription-PCR assay was performed to obtain cDNA. Canine-specific cytokine mRNA expression was determined by use of a real-time PCR assay. Interleukin (IL)-8 and -10 and interferon-gamma expression differed significantly between dogs with arthropathies and dogs with normal stifle joints. For the 14 dogs with unilateral CrCL rupture, a significant difference was found for IL-8 expression. Before reconstructive surgery, IL-8 expression differed significantly between the affected stifle joint and left shoulder joint or contralateral stifle joint. Six months after surgery, IL-8 expression was significantly increased in the unaffected contralateral stifle joint, compared with the shoulder joint. No conclusions can be made regarding the role of the examined cytokines in initiation of CrCL disease.

  8. Hip joint injection

    MedlinePlus

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  9. Investigation Leads to Improved Understanding of Space Shuttle RSRM Internal Insulation Joints

    NASA Technical Reports Server (NTRS)

    McWhorter, Bruce B.; Bolton, Doug E.; Hicken, Steve V.; Allred, Larry D.; Cook, Dave J.

    2003-01-01

    PSA has been weakened due to humidity, then the J-joint will partially pull apart (inboard side), and the J-joint surfaces will be charred by exposure to hot gases. After early operation, a J-joint that has been pulled apart will come back together as the J-joint deformation decreases. This J-joint heating event is relatively short and occurs only during the first part of motor operation. Internal instrumentation was developed for another full-scale static test in February 2000. The static test instrumentation did indeed prove this theory to be correct. Post-test inspection revealed very similar charring characteristics as observed on RSRM-55. This experience of the development of a new PSA, its testing, the RSRM-55 flight, followed by the J-joint investigation led to good 'lessons learned' and to an additional fundamental understanding of the RSRM J-joint function.

  10. Joint Aspiration (Arthrocentesis)

    MedlinePlus

    ... arthritis, or JRA), systemic lupus erythematosus (SLE), and Lyme disease. Joint aspiration is diagnostic but it also can ... topic for: Parents Kids Teens Evaluate Your Child's Lyme Disease Risk Living With Lupus Bones, Muscles, and Joints ...

  11. Estimation of Vickers hardness uncertainty for a heterogeneous welded joint (S235JR+AR and X2CrNiMo17-12-2)

    NASA Astrophysics Data System (ADS)

    Dijmărescu, M. C.; Dijmărescu, M. R.

    2017-08-01

    When talking about tests that include measurements, the uncertainty of measurement is an essential element because it is important to know the limits within the obtained results may be assumed to lie and the influence the measurement technological system elements have on these results. The research presented in this paper focuses on the estimation of the Vickers hardness uncertainty of measurement for the heterogeneous welded joint between S235JR+AR and X2CrNiMo17-12-2 materials in order to establish the results relevance and the quality assessment of this joint. The paper contents are structured in three main parts. In the first part, the initial data necessary for the experiment is presented in terms of the welded joint and technological means characterisation. The second part presents the physical experiment development and its results and in the third part the uncertainty of the measurements is calculated and a results discussion is undertaken.

  12. Joint Control for Dummies: An Elaboration of Lowenkron's Model of Joint (Stimulus) Control

    ERIC Educational Resources Information Center

    Sidener, David W.

    2006-01-01

    The following paper describes Lowenkron's model of joint (stimulus) control. Joint control is described as a means of accounting for performances, especially generalized performances, for which a history of contingency control does not provide an adequate account. Examples are provided to illustrate instances in which joint control may facilitate…

  13. 50 CFR Appendix C to Part 404 - Boundary Coordinated for Papaha

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 11 2013-10-01 2013-10-01 false Boundary Coordinated for Papaha C Appendix C to Part 404 Wildlife and Fisheries JOINT REGULATIONS (UNITED STATES FISH AND WILDLIFE SERVICE... HAWAIIAN ISLANDS MARINE NATIONAL MONUMENT Pt. 404, App. C Appendix C to Part 404—Boundary Coordinated for...

  14. 50 CFR Appendix C to Part 404 - Boundary Coordinated for Papaha

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false Boundary Coordinated for Papaha C Appendix C to Part 404 Wildlife and Fisheries JOINT REGULATIONS (UNITED STATES FISH AND WILDLIFE SERVICE... HAWAIIAN ISLANDS MARINE NATIONAL MONUMENT Pt. 404, App. C Appendix C to Part 404—Boundary Coordinated for...

  15. 50 CFR Appendix D to Part 404 - Boundary Coordinates for Papaha

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Boundary Coordinates for Papaha D Appendix D to Part 404 Wildlife and Fisheries JOINT REGULATIONS (UNITED STATES FISH AND WILDLIFE SERVICE... HAWAIIAN ISLANDS MARINE NATIONAL MONUMENT Pt. 404, App. D Appendix D to Part 404—Boundary Coordinates for...

  16. Isolation and Characterization of Human Mesenchymal Stem Cells From Facet Joints and Interspinous Ligaments.

    PubMed

    Kristjánsson, Baldur; Limthongkul, Worawat; Yingsakmongkol, Wicharn; Thantiworasit, Pattarawat; Jirathanathornnukul, Napaphat; Honsawek, Sittisak

    2016-01-01

    A descriptive in vitro study on isolation and differentiation of human mesenchymal stem cells (MSCs) derived from the facet joints and interspinous ligaments. To isolate cells from the facet joints and interspinous ligaments and investigate their surface marker profile and differentiation potentials. Lumbar spinal canal stenosis and ossification of the posterior longitudinal ligament are progressive conditions characterized by the hypertrophy and ossification of ligaments and joints within the spinal canal. MSCs are believed to play a role in the advancement of these diseases and the existence of MSCs has been demonstrated within the ligamentum flavum and posterior longitudinal ligament. The aim of this study was to investigate whether these cells could also be found within facet joints and interspinous ligaments. Samples were harvested from 10 patients undergoing spinal surgery. The MSCs from facet joints and interspinous ligaments were isolated using direct tissue explant technique. Cell surface antigen profilings were performed via flow cytometry. Their lineage differentiation potentials were analyzed. The facet joints and interspinous ligaments-derived MSCs have the tri-lineage potential to be differentiated into osteogenic, adipogenic, and chondrogenic cells under appropriate inductions. Flow cytometry analysis revealed both cell lines expressed MSCs markers. Both facet joints and interspinous ligaments-derived MSCs expressed marker genes for osteoblasts, adipocytes, and chondrocytes. The facet joints and interspinous ligaments may provide alternative sources of MSCs for tissue engineering applications. The facet joints and interspinous ligaments-derived MSCs are part of the microenvironment of the human ligaments of the spinal column and might play a crucial role in the development and progression of degenerative spine conditions.

  17. Behaviour of Frictional Joints in Steel Arch Yielding Supports

    NASA Astrophysics Data System (ADS)

    Horyl, Petr; Šňupárek, Richard; Maršálek, Pavel

    2014-10-01

    The loading capacity and ability of steel arch supports to accept deformations from the surrounding rock mass is influenced significantly by the function of the connections and in particular, the tightening of the bolts. This contribution deals with computer modelling of the yielding bolt connections for different torques to determine the load-bearing capacity of the connections. Another parameter that affects the loading capacity significantly is the value of the friction coefficient of the contacts between the elements of the joints. The authors investigated both the behaviour and conditions of the individual parts for three values of tightening moment and the relation between the value of screw tightening and load-bearing capacity of the connections for different friction coefficients. ANSYS software and the finite element method were used for the computer modelling. The solution is nonlinear because of the bi-linear material properties of steel and the large deformations. The geometry of the computer model was created from designs of all four parts of the structure. The calculation also defines the weakest part of the joint's structure based on stress analysis. The load was divided into two loading steps: the pre-tensioning of connecting bolts and the deformation loading corresponding to 50-mm slip of one support. The full Newton-Raphson method was chosen for the solution. The calculations were carried out on a computer at the Supercomputing Centre VSB-Technical University of Ostrava.

  18. High pressure ceramic joint

    DOEpatents

    Ward, Michael E.; Harkins, Bruce D.

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  19. Joint Implications for Contracted Logistics

    DTIC Science & Technology

    2007-03-30

    authority with the host nation country and policy on using UCMJ for contracted personnel. As tailored theater policies are developed and contracting...responsibility, this paper recommends better joint training, leader development and joint enablers for contracting operations. JOINT...U.S. Joint Forces Command (JFCOM) are analyzing Congressional and DOD policy to develop procedures and force structure to support contractor

  20. Comparison of the use of notched wedge joints vs. traditional butt joints in Connecticut

    DOT National Transportation Integrated Search

    2008-11-07

    Performance of Hot Mix Asphalt (HMA) longitudinal joints have been an item of increasing scrutiny in : Connecticut. The traditional butt joint has typically been the method used in Connecticut. These joints : have been reportedly opening up, creating...

  1. The Load Distribution in Bolted or Riveted Joints in Light-Alloy Structures

    NASA Technical Reports Server (NTRS)

    Vogt, F.

    1947-01-01

    This report contains a theoretical discussion of the load distribution in bolted or riveted joints in light-alloy structures which is applicable not only for loads below the limit of proportionality but also for loads above this limit. The theory is developed for double and single shear joints. The methods given are illustrated by numerical examples and the values assumed for the bolt (or rivet) stiffnesses are based partly on theory and partly on known experimental values. It is shown that the load distribution does not vary greatly with the bolt (or rivet) stiffnesses and that for design purposes it is usually sufficient to know their order of magnitude. The theory may also be directly used for spot-welded structures and, with small modifications, for seam-welded structures, The computational work involved in the methods described is simple and may be completed in a reasonable time for most practical problems. A summary of earlier theoretical and experimental investigations on the subject is included in the report.

  2. Correlations between iron content in knee joint tissues and chosen indices of peripheral blood morphology.

    PubMed

    Brodziak-Dopierała, Barbara; Roczniak, Wojciech; Jakóbik-Kolon, Agata; Kluczka, Joanna; Koczy, Bogdan; Kwapuliński, Jerzy; Babuśka-Roczniak, Magdalena

    2017-10-01

    Iron as a cofactor of enzymes takes part in the synthesis of the bone matrix. Severe deficiency of iron reduces the strength and mineral density of bones, whereas its excess may increase oxidative stress. In this context, it is essential to determine the iron content in knee joint tissues. The study objective was to determine the level of iron in the tissues of the knee joint, i.e., in the femoral bone, tibia and meniscus. Material for analysis was obtained during endoprosthetic surgery of the knee joint. Within the knee joint, the tibia, femur and meniscus were analyzed. Samples were collected from 50 patients, including 36 women and 14 men. The determination of iron content was performed with the ICP-AES method, using Varian 710-ES. The lowest iron content was in the tibia (27.04 μg/g), then in the meniscus (38.68 μg/g) and the highest in the femur (41.93 μg/g). Statistically significant differences were noted in the content of iron in knee joint tissues. In patients who underwent endoprosthesoplasty of the knee joint, statistically significant differences were found in the levels of iron in various components of the knee joint. The highest iron content was found in the femoral bone of the knee joint and then in the meniscus, the lowest in the tibia. The differences in iron content in the knee joint between women and men were not statistically significant.

  3. Evaluation of narrow transverse contraction joints in jointed plain concrete pavements.

    DOT National Transportation Integrated Search

    2006-03-01

    This report presents the results of a research project conducted at the Louisiana Transportation Research Center (LTRC) to evaluate the performance of narrow transverse contraction joints to control cracking in jointed plain concrete pavements. In ad...

  4. Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

    NASA Technical Reports Server (NTRS)

    Verhage, Joseph M.; Bower, Mark V.; Gilbert, Paul A. (Technical Monitor)

    2001-01-01

    The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

  5. Longitudinal joint treatment.

    DOT National Transportation Integrated Search

    2006-03-01

    Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...

  6. Thermal Cycling Fatigue in DIPs Mounted with Eutectic Tin-Lead Solder Joints in Stub and Gullwing Geometries

    NASA Technical Reports Server (NTRS)

    Winslow, J. W.; Silveira, C. de

    1993-01-01

    It has long been known that solder joints under mechanical stress are subject to failure. In early electronic systems, such failures were avoided primarily by avoiding the use of solder as a mechanical structural component. The rule was first to make sound wire connections that did not depend mechanically on solder, and only then to solder them. Careful design and miniaturization in modern electronic systems limits the mechanical stresses exerted on solder joints to values less than their yield points, and these joints have become integral parts of the mechanical structures. Unfortunately, while these joints are strong enough when new, they have proven vulnerable to fatigue failures as they age. Details of the fatigue process are poorly understood, making predictions of expected lifetimes difficult.

  7. Microstructure and Mechanical Properties of Hybrid Welded Joints with Laser and CO2-Shielded Arc

    NASA Astrophysics Data System (ADS)

    Wahba, M.; Mizutani, M.; Katayama, S.

    2016-07-01

    With the objective of reducing the operating costs, argon-rich shielding gas was replaced by 100% CO2 gas in hybrid laser-arc welding of shipbuilding steel. The welding parameters were optimized to obtain buried-arc transfer in order to mitigate spatter formation. Sound butt joints could be successfully produced for plates of 14 and 17 mm thickness in one welding pass. Subsequently, the welded joints were subjected to different tests to evaluate the influence of CO2 shielding gas on the mechanical properties of the welded joints. All tensile-tested specimens failed in the base material, indicating the higher strength of the welded joints. The impact toughness of the welded joints, measured at -20 °C, reached approximately 76% of that of the base material, which was well above the limit set by the relevant standard. The microstructure of the fusion zone consisted of grain boundary ferrite and acicular ferrite uniformly over the plate thickness except for the joint root where the microstructure was chiefly ferrite with an aligned second phase. This resulted in higher hardness in the root region compared with the top and middle parts of the fusion zone.

  8. Vocabulary Development and Maintenance--Descriptors. ERIC Processing Manual, Section VIII (Part 1).

    ERIC Educational Resources Information Center

    Houston, Jim, Ed.

    Comprehensive rules, guidelines, and examples are provided for use by ERIC indexers and lexicographers in developing and maintaining the "Thesaurus of ERIC Descriptors." Evaluation and decision criteria, research procedures, and inputting details for adding new Descriptors are documented. Instructions for modifying existing Thesaurus…

  9. Determination of representative dimension parameter values of Korean knee joints for knee joint implant design.

    PubMed

    Kwak, Dai Soon; Tao, Quang Bang; Todo, Mitsugu; Jeon, Insu

    2012-05-01

    Knee joint implants developed by western companies have been imported to Korea and used for Korean patients. However, many clinical problems occur in knee joints of Korean patients after total knee joint replacement owing to the geometric mismatch between the western implants and Korean knee joint structures. To solve these problems, a method to determine the representative dimension parameter values of Korean knee joints is introduced to aid in the design of knee joint implants appropriate for Korean patients. Measurements of the dimension parameters of 88 male Korean knee joint subjects were carried out. The distribution of the subjects versus each measured parameter value was investigated. The measured dimension parameter values of each parameter were grouped by suitable intervals called the "size group," and average values of the size groups were calculated. The knee joint subjects were grouped as the "patient group" based on "size group numbers" of each parameter. From the iterative calculations to decrease the errors between the average dimension parameter values of each "patient group" and the dimension parameter values of the subjects, the average dimension parameter values that give less than the error criterion were determined to be the representative dimension parameter values for designing knee joint implants for Korean patients.

  10. Novel Ultrasound Joint Selection Methods Using a Reduced Joint Number Demonstrate Inflammatory Improvement when Compared to Existing Methods and Disease Activity Score at 28 Joints.

    PubMed

    Tan, York Kiat; Allen, John C; Lye, Weng Kit; Conaghan, Philip G; D'Agostino, Maria Antonietta; Chew, Li-Ching; Thumboo, Julian

    2016-01-01

    A pilot study testing novel ultrasound (US) joint-selection methods in rheumatoid arthritis. Responsiveness of novel [individualized US (IUS) and individualized composite US (ICUS)] methods were compared with existing US methods and the Disease Activity Score at 28 joints (DAS28) for 12 patients followed for 3 months. IUS selected up to 7 and 12 most ultrasonographically inflamed joints, while ICUS additionally incorporated clinically symptomatic joints. The existing, IUS, and ICUS methods' standardized response means were -0.39, -1.08, and -1.11, respectively, for 7 joints; -0.49, -1.00, and -1.16, respectively, for 12 joints; and -0.94 for DAS28. Novel methods effectively demonstrate inflammatory improvement when compared with existing methods and DAS28.

  11. Accuracy of acromioclavicular joint injections.

    PubMed

    Wasserman, Bradley R; Pettrone, Sarah; Jazrawi, Laith M; Zuckerman, Joseph D; Rokito, Andrew S

    2013-01-01

    Injection to the acromioclavicular (AC) joint can be both diagnostic and therapeutic. The purpose of this study was to evaluate the accuracy of in vivo AC joint injections. Case series; Level of evidence, 4. Thirty patients with pain localized to the AC joint were injected with 1 mL of 1% lidocaine and 0.5 mL of radiographic contrast material (Isovue). Radiographs of the AC joint were taken after the injection. Each radiograph was reviewed by a musculoskeletal radiologist and graded as intra-articular, extra-articular, or partially intra-articular. Of the 30 injections performed, 13 (43.3%) were intra-articular, 7 (23.3%) were partially articular, and 10 (33.3%) were extra-articular. When the intra-articular and the partially articular groups were combined, 20 patients (66.7%) had some contrast dye in the AC joint. This study demonstrates that despite the relatively superficial location of the AC joint, the clinical accuracy of AC joint injections remains relatively low.

  12. What a Joint. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in helping students become familiar with meat processing--livestock at the stockyards, meat packers (wholesalers), and butcher shops--to the cooked state and to become familiar with the different joints (cuts or parts) of beef, lamb, and pork. The guide…

  13. Concept for a fast analysis method of the energy dissipation at mechanical joints

    NASA Astrophysics Data System (ADS)

    Wolf, Alexander; Brosius, Alexander

    2017-10-01

    When designing hybrid parts and structures one major challenge is the design, production and quality assessment of the joining points. While the polymeric composites themselves have excellent material properties, the necessary joints are often the weak link in assembled structures. This paper presents a method of measuring and analysing the energy dissipation at mechanical joining points of hybrid parts. A simplified model is applied based on the characteristic response to different excitation frequencies and amplitudes. The dissipation from damage is the result of relative moments between joining partners und damaged fibres within the composite, whereas the visco-elastic material behaviour causes the intrinsic dissipation. The ambition is to transfer these research findings to the characterisation of mechanical joints in order to quickly assess the general quality of the joint with this non-destructive testing method. The inherent challenge for realising this method is the correct interpretation of the measured energy dissipation and its attribution to either a bad joining point or intrinsic material properties. In this paper the authors present the concept for energy dissipation measurements at different joining points. By inverse analysis a simplified fast semi-analytical model will be developed that allows for a quick basic quality assessment of a given joining point.

  14. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    PubMed

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Joint project of the international network of agencies for health technology assessment--Part 1: Survey results on diffusion, assessment, and clinical use of positron emission tomography.

    PubMed

    Hastings, John; Adams, Elizabeth J

    2006-01-01

    The International Network of Agencies for Health Technology Assessment (INAHTA) has been tracking activities associated with the clinical use of positron emission tomography (PET) in its members' healthcare systems since 1997 and published its first Joint Project report on PET in 1999. Part 1 of this Joint Project report presents survey results on diffusion, assessment activities, and policy for clinical use related to PET among INAHTA members since 1999. INAHTA members were surveyed in 2003-2004. Twenty-seven INAHTA agencies (69 percent response rate) from nineteen countries responded to the survey. Dedicated PET systems are the most universally installed systems to date. Mobile scanners and modified gamma cameras are used occasionally as lower cost alternatives, and interest in PET-computed tomography hybrid models is rising despite limited assessment of impact on service planning. PET was used and assessed most commonly for managing patients with cancer. All respondents reported having some form of public funding for clinical PET frequently linked to data collection for the purpose of gathering evidence to refine clinical use and guide resource allocation toward indications that maximize clinical and cost-effectiveness. The use of HTA within a continuous quality improvement framework can help optimize scarce resources for evaluation and use of high cost diagnostic technologies such as PET, particularly where potential clinical or cost-effectiveness is considerable but conclusive evidence is lacking.

  16. Design of a simple, lightweight, passive-elastic ankle exoskeleton supporting ankle joint stiffness

    NASA Astrophysics Data System (ADS)

    Kim, Seyoung; Son, Youngsu; Choi, Sangkyu; Ham, Sangyong; Park, Cheolhoon

    2015-09-01

    In this study, a passive-elastic ankle exoskeleton (PEAX) with a one-way clutch mechanism was developed and then pilot-tested with vertical jumping to determine whether the PEAX is sufficiently lightweight and comfortable to be used in further biomechanical studies. The PEAX was designed to supplement the function of the Achilles tendon and ligaments as they passively support the ankle torque with their inherent stiffness. The main frame of the PEAX consists of upper and lower parts connected to each other by tension springs (N = 3) and lubricated hinge joints. The upper part has an offset angle of 5° with respect to the vertical line when the springs are in their resting state. Each spring has a slack length of 8 cm and connects the upper part to the tailrod of the lower part in the neutral position. The tailrod freely rotates with low friction but has a limited range of motion due to the stop pin working as a one-way clutch. Because of the one-way clutch system, the tension springs store the elastic energy only due to an ankle dorsiflexion when triggered by the stop pin. This clutch mechanism also has the advantage of preventing any inconvenience during ankle plantarflexion because it does not limit the ankle joint motion during the plantarflexion phase. In pilot jumping tests, all of the subjects reported that the PEAX was comfortable for jumping due to its lightweight (approximately 1 kg) and compact (firmly integrated with shoes) design, and subjects were able to nearly reach their maximum vertical jump heights while wearing the PEAX. During the countermovement jump, elastic energy was stored during dorsiflexion by spring extension and released during plantarflexion by spring restoration, indicating that the passive spring torque (i.e., supportive torque) generated by the ankle exoskeleton partially supported the ankle joint torque throughout the process.

  17. Design of a simple, lightweight, passive-elastic ankle exoskeleton supporting ankle joint stiffness.

    PubMed

    Kim, Seyoung; Son, Youngsu; Choi, Sangkyu; Ham, Sangyong; Park, Cheolhoon

    2015-09-01

    In this study, a passive-elastic ankle exoskeleton (PEAX) with a one-way clutch mechanism was developed and then pilot-tested with vertical jumping to determine whether the PEAX is sufficiently lightweight and comfortable to be used in further biomechanical studies. The PEAX was designed to supplement the function of the Achilles tendon and ligaments as they passively support the ankle torque with their inherent stiffness. The main frame of the PEAX consists of upper and lower parts connected to each other by tension springs (N = 3) and lubricated hinge joints. The upper part has an offset angle of 5° with respect to the vertical line when the springs are in their resting state. Each spring has a slack length of 8 cm and connects the upper part to the tailrod of the lower part in the neutral position. The tailrod freely rotates with low friction but has a limited range of motion due to the stop pin working as a one-way clutch. Because of the one-way clutch system, the tension springs store the elastic energy only due to an ankle dorsiflexion when triggered by the stop pin. This clutch mechanism also has the advantage of preventing any inconvenience during ankle plantarflexion because it does not limit the ankle joint motion during the plantarflexion phase. In pilot jumping tests, all of the subjects reported that the PEAX was comfortable for jumping due to its lightweight (approximately 1 kg) and compact (firmly integrated with shoes) design, and subjects were able to nearly reach their maximum vertical jump heights while wearing the PEAX. During the countermovement jump, elastic energy was stored during dorsiflexion by spring extension and released during plantarflexion by spring restoration, indicating that the passive spring torque (i.e., supportive torque) generated by the ankle exoskeleton partially supported the ankle joint torque throughout the process.

  18. [Effects of exercise on joints.

    PubMed

    Moriyama, Hideki

    Joints are composed of several different tissues(cartilage, capsule, meniscus, and ligament), and articular cartilage plays an important role in maintaining mechanical competence during exercise. Weight-bearing exercise has several benefit, including improved blood and synovial fluid circulation in a given joint. Consistent moderate activities facilitate cycles of anabolism and catabolism. Mechanical stresses are crucial for the maintenance of the morphologic and functional integrity of articular cartilage. Healthy cartilage is exposed by hydrostatic pressure and tensile strain, when cartilage degeneration develops, abnormal cartilage is exposed by shear stress. Moderate(physiological)exercise is characterized by a range of equilibrium between matrix anabolic and catabolic processes, or anabolism beyond catabolism. Joints are susceptible to insufficient or excessive activities, leading to joint degeneration. Lack of exercise is known to induce joint contracture seen clinically as a consequence of disuse changes, and excess mechanical stresses induce joint destruction such as osteoarthritis. Joint diseases resulting from insufficient or excessive activities are new and major challenging issues with our aging population. Thus, it is highly desirable to have an effective and efficient treatment to improve and protect against these joint diseases, and thereby to solve these clearly unanswered issues.

  19. [A new type sternoclavicular hook plate for unstable sternoclavicular joint dislocation and fracture].

    PubMed

    Zhang, Chuan-Yi; Lin, Lie; Liang, Jun-Bo; Wang, Bin; Chen, Guo-Fu; Chen, Hai-Xiao

    2016-11-25

    To evaluate the therapeutic effect of a new type sternoclavicular hook plate fixation in treating unstable sternoclavicular joint dislocation and fracture. From June 2011 to December 2013, 32 patients with sternoclavicular joint dislocation and fracture were treated with a new type sternoclavicular hook plate fixation, including 24 males and 8 females with an average age of 42 years ranging from 25 to 76 years;12 patients were anterior dislocation, 5 pations were posterior dislocation, 10 patients were internal extremity of clavicle fracture and 5 patients were sternoclavicular joint dislocation combined with fracture. The anterior fracture dislocation of the sternoclavicular joint adopted standard sternoclavicular joint hook plate, and the posterior dislocation was at the distal end of the hook of the steel plate, that is, the front part of the handle of the breast was added with a nut and a gasket to prevent the re-dislocation after operation. The results were evaluated according to Rockwood score. No complication happened in all patients. X-ray and CT showed that the dislocation and fracture of the sternoclavicular joint was well reduced and the plate was on right position. All patients were followed up for 6 to 24 months with an average of 10 months. At 6 to 3 months after operation, the fracture was healing without re-dislocation of the sternoclavicular joint, the medial end of the clavicle anatomical structure were restored, functional satisfaction, in which 9 patients with the swelling around sternoclavicular joint, but no pain and other symptoms. The total Rockwood score was 12.78±1.43; the results were excellent in 24 cases, good in 8 cases. The use of the new type of locking hook plate for the treatment of unstable fracture of the sternoclavicular joint, internal fixation is reliable, high security, easy to operate, to provide a reliable method for the treatment of such trauma.

  20. Functional disorders of the temporomandibular joints: Internal derangement of the temporomandibular joint.

    PubMed

    Chang, Chih-Ling; Wang, Ding-Han; Yang, Mu-Chen; Hsu, Wun-Eng; Hsu, Ming-Lun

    2018-04-01

    Temporomandibular joint (TMJ) is one of the most complex joints of the human body. Due to its unique movement, in terms of combination of rotation and translator movement, disc of the joint plays an important role to maintain its normal function. In order to sustain the normal function of the TMJ, disc must be kept in proper position as well as maintain normal shape in all circumstances. Once the disc is not any more in its normal position during function of the joint, disturbance of the joint can be occurred which will lead to subsequent distortion of the disc. Shape of the disc can be influenced by many factors i.e.: abnormal function or composition of the disc itself. Etiology of the internal derangement of the disc remains controversial. Multifactorial theory has been postulated in most of previous manuscripts. Disc is composed of mainly extracellular matrix. Abnormal proportion of collagen type I & III may also leads to joint hypermobility which may be also a predisposing factor of this disorder. Thus it can be recognized as local manifestation of a systemic disorder. Different treatment modalities with from conservative treatment to surgical intervention distinct success rate have been reported. Recently treatment with extracellular matrix injection becomes more and more popular to strengthen the joint itself. Since multifactorial in character, the best solution of the treatment modalities should be aimed to resolve possible etiology from different aspects. Team work may be indication to reach satisfied results. Copyright © 2018. Published by Elsevier Taiwan.

  1. Predicting the Functional Roles of Knee Joint Muscles from Internal Joint Moments.

    PubMed

    Flaxman, Teresa E; Alkjær, Tine; Simonsen, Erik B; Krogsgaard, Michael R; Benoit, Daniel L

    2017-03-01

    Knee muscles are commonly labeled as flexors or extensors and aptly stabilize the knee against sagittal plane loads. However, how these muscles stabilize the knee against adduction-abduction and rotational loads remains unclear. Our study sought 1) to classify muscle roles as they relate to joint stability by quantifying the relationship between individual muscle activation patterns and internal net joint moments in all three loading planes and 2) to determine whether these roles change with increasing force levels. A standing isometric force matching protocol required subjects to modulate ground reaction forces to elicit various combinations and magnitudes of sagittal, frontal, and transverse internal joint moments. Surface EMG measured activities of 10 lower limb muscles. Partial least squares regressions determined which internal moment(s) were significantly related to the activation of individual muscles. Rectus femoris and tensor fasciae latae were classified as moment actuators for knee extension and hip flexion. Hamstrings were classified as moment actuators for hip extension and knee flexion. Gastrocnemius and hamstring muscles were classified as specific joint stabilizers for knee rotation. Vastii were classified as general joint stabilizers because activation was independent of moment generation. Muscle roles did not change with increasing effort levels. Our findings indicate muscle activation is not dependent on anatomical orientation but perhaps on its role in maintaining knee joint stability in the frontal and transverse loading planes. This is useful for delineating the roles of biarticular knee joint muscles and could have implications in robotics, musculoskeletal modeling, sports sciences, and rehabilitation.

  2. Approaches to the construction of a medical informatics glossary and thesaurus.

    PubMed

    Rada, R; Ghaoui, C; Russell, J; Taylor, M

    1993-01-01

    In a project concerned with establishing a glossary and thesaurus for the medical informatics domain, various approaches to the task have been investigated. The developers take the view that a glossary should be a coherent system of terms, reflecting a coherent system of concepts that underlies a body of knowledge about a domain. A framework for the conceptual analysis of the concepts/terms underlying the domain has been developed. The emphasis of this framework is on how the concepts relate together. This work has given an important insight into how the practical task of establishing well-structured vocabularies for a field can be better achieved. An eclectic approach to term selection was adopted. Criteria for assessing what constitutes good definitions for concepts in a field were examined. Using all these approaches glossaries, thesauri and domain models of the medical informatics field are being developed. Another aspect of our work of particular interest is the development of attributed definitions from which inheritance patterns can be defined.

  3. New Joint Sealants. Criteria, Design and Materials.

    ERIC Educational Resources Information Center

    Building Research Inst., Inc., Washington, DC.

    Contents include--(1) sealing concrete joints, (2) sealing glass and metal joints, (3) metal and glass joint sealants from a fabricator's viewpoint, (4) a theory of adhesion for joint sealants, (5) geometry of simple joint seals under strain, (6) joint sealant specifications from a manufacturer's viewpoint, (7) joint sealant requirements from an…

  4. Apollo-Soyuz US-USSR joint mission results

    NASA Technical Reports Server (NTRS)

    Bean, A. L.; Evans, R. E.

    1975-01-01

    The technical and nontechnical objectives of the Apollo-Soyuz mission are briefly considered. The mission demonstrated that Americans and Russians can work together to perform a very complex operation, including rendezvous in space, docking, and the conduction of joint experiments. Certain difficulties which had to be overcome were partly related to differences concerning the role of the astronaut in the basic alignment and docking procedures for space vehicles. Attention is also given to the experiments conducted during the mission and the approach used to overcome the language barrier.

  5. Steroid injections - tendon, bursa, joint

    MedlinePlus

    ... a small amount of corticosteroid and a local anesthetic into the bursa. JOINT Any joint problem, such ... A small amount of corticosteroid and a local anesthetic will be injected into the joint. TENDON A ...

  6. High pressure ceramic joint

    DOEpatents

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  7. [Classification and Treatment of Sacroiliac Joint Dislocation].

    PubMed

    Tan, Zhen; Huang, Zhong; Li, Liang; Meng, Wei-Kun; Liu, Lei; Zhang, Hui; Wang, Guang-Lin; Huang, Fu-Guo

    2017-09-01

    To develop a renewed classification and treatment regimen for sacroiliac joint dislocation. According to the direction of dislocation of sacroiliac joint,combined iliac,sacral fractures,and fracture morphology,sacroiliac joint dislocation was classified into 4 types. Type Ⅰ (sacroiliac anterior dislocation): main fracture fragments of posterior iliac wing dislocated in front of sacroiliac joint. Type Ⅱ (sacroiliac posterior dislocation): main fracture fragments of posterior iliac wing dislocated in posterior of sacroiliac joint. Type Ⅲ (Crescent fracturedislocation of the sacroiliac joint): upward dislocation of posterior iliac wing with oblique fracture through posterior iliac wing. Type ⅢA: a large crescent fragment and dislocation comprises no more than onethird of sacroiliac joint,which is typically inferior. Type ⅢB: intermediatesize crescent fragment and dislocation comprises between one and twothirds of joint. Type ⅢC: a small crescent fragment where dislocation comprises most,but not the entire joint. Different treatment regimens were selected for different types of fractures. Treatment for type Ⅰ sacroiliac joint dislocation: anterior iliac fossa approach pry stripping reset; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅱ sacroiliac joint dislocation: posterior sacroiliac joint posterior approach; sacroiliac joint fixed with sacroiliac screw under computer guidance. Treatment for type ⅢA and ⅢB sacroiliac joint dislocation: posterior sacroiliac joint approach; sacroiliac joint fixed with reconstruction plate. Treatment for type ⅢC sacroiliac joint dislocation: sacroiliac joint closed reduction; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅳ sacroiliac joint dislocation: posterior approach; sacroiliac joint fixed with spinal pelvic fixation. Results of 24 to 72 months patient follow-up (mean 34.5 months): 100% survival,100% wound healing,and 100

  8. Sacroiliac joint tuberculosis

    PubMed Central

    Govender, S.

    2006-01-01

    Infections of the sacroiliac joint are uncommon and the diagnosis is usually delayed. In a retrospective study, 17 patients who had been treated for tuberculosis sacroiliitis between 1994 and 2004 were reviewed. Two patients were excluded due to a short follow-up (less than 2 years). Low back pain and difficulty in walking were the most common presenting features. Two patients presented with a buttock abscess and spondylitis of the lumbar spine was noted in two patients. The Gaenslen’s and FABER (flexion, abduction and external rotation) tests were positive in all patients. Radiological changes included loss of cortical margins with erosion of the joints. An open biopsy and curettage was performed in all patients; histology revealed chronic infection and acid-fast bacilli were isolated in nine patients. Antituberculous (TB) medication was administered for 18 months and the follow-up ranged from 3 to 10 years (mean: 5 years). The sacroiliac joint fused spontaneously within 2 years. Although all patients had mild discomfort in the lower back following treatment they had no difficulty in walking. Sacroiliac joint infection must be included in the differential diagnosis of lower back pain and meticulous history and clinical evaluation of the joint are essential. PMID:16673102

  9. Lower limb joint work and joint work contribution during downhill and uphill walking at different inclinations.

    PubMed

    Alexander, Nathalie; Strutzenberger, Gerda; Ameshofer, Lisa Maria; Schwameder, Hermann

    2017-08-16

    Work performance and individual joint contribution to total work are important information for creating training protocols, but were not assessed so far for sloped walking. Therefore, the purpose of this study was to analyze lower limb joint work and joint contribution of the hip, knee and ankle to total lower limb work during sloped walking in a healthy population. Eighteen male participants (27.0±4.7yrs, 1.80±0.05m, 74.5±8.2kg) walked on an instrumented ramp at inclination angles of 0°, ±6°, ±12° and ±18° at 1.1m/s. Kinematic and kinetic data were captured using a motion-capture system (Vicon) and two force plates (AMTI). Joint power curves, joint work (positive, negative, absolute) and each joint's contribution to total lower limb work were analyzed throughout the stance phase using an ANOVA with repeated measures. With increasing inclination positive joint work increased for the ankle and hip joint and in total during uphill walking. Negative joint work increased for each joint and in total work during downhill walking. Absolute work was increased during both uphill (all joints) and downhill (ankle & knee) walking. Knee joint contribution to total negative and absolute work increased during downhill walking while hip and ankle contributions decreased. This study identified, that, when switching from level to a 6° and from 6° to a 12° inclination the gain of individual joint work is more pronounced compared to switching from 12° to an 18° inclination. The results might be used for training recommendations and specific training intervention with respect to sloped walking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Development of the joint munitions planning system - a planning tool for the ammunition community.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hummel, J. R.; Winiecki, A. L.; Fowler, R. S.

    2004-10-01

    The United States Army Joint Munitions Command (JMC) is the executive agent for the Single Manager for Conventional Ammunition (SMCA). As such the JMC is responsible for the storage and transportation of all Service's SMCA as well as non-SMCA munitions. Part of the JMC mission requires that complex depot capacity studies, transportation capabilities analyses, peacetime re-allocations/ redistribution plans and time-phased deployment distribution plans be developed. Beginning in 1999 the Joint Munitions Planning System (JMPS) was developed to provide sourcing and movement solutions of ammunition for military planners.

  11. Utilization of Facet Joint and Sacroiliac Joint Interventions in Medicare Population from 2000 to 2014: Explosive Growth Continues!

    PubMed

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Pampati, Vidyasagar; Boswell, Mark V

    2016-10-01

    Increasing utilization of interventional techniques in managing chronic spinal pain, specifically facet joint interventions and sacroiliac joint injections, is a major concern of healthcare policy makers. We analyzed the patterns of utilization of facet and sacroiliac joint interventions in managing chronic spinal pain. The results showed significant increase of facet joint interventions and sacroiliac joint injections from 2000 to 2014 in Medicare FFS service beneficiaries. Overall, the Medicare population increased 35 %, whereas facet joint and sacroiliac joint interventions increased 313.3 % per 100,000 Medicare population with an annual increase of 10.7 %. While the increases were uniform from 2000 to 2014, there were some decreases noted for facet joint interventions in 2007, 2010, and 2013, whereas for sacroiliac joint injections, the decreases were noted in 2007 and 2013. The increases were for cervical and thoracic facet neurolysis at 911.5 % compared to lumbosacral facet neurolysis of 567.8 %, 362.9 % of cervical and thoracic facet joint blocks, 316.9 % of sacroiliac joints injections, and finally 227.3 % of lumbosacral facet joint blocks.

  12. Ball-joint grounding ring

    NASA Technical Reports Server (NTRS)

    Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.

    1981-01-01

    In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

  13. A low cost wearable optical-based goniometer for human joint monitoring

    NASA Astrophysics Data System (ADS)

    Lim, Chee Kian; Luo, Zhiqiang; Chen, I.-Ming; Yeo, Song Huat

    2011-03-01

    Widely used in the fields of physical and occupational therapy, goniometers are indispensible when it comes to angular measurement of the human joint. In both fields, there is a need to measure the range of motion associated with various joints and muscle groups. For example, a goniometer may be used to help determine the current status of the range of motion in bend the arm at the elbow, bending the knee, or bending at the waist. The device can help to establish the range of motion at the beginning of the treatment series, and also allow the therapist to monitor progress during subsequent sessions. Most commonly found are the mechanical goniometers which are inexpensive but bulky. As the parts are mechanically linked, accuracy and resolution are largely limited. On the other hand, electronic and optical fiberbased goniometers promise better performance over its mechanical counterpart but due to higher cost and setup requirements does not make it an attractive proposition as well. In this paper, we present a reliable and non-intrusive design of an optical-based goniometer for human joint measurement. This device will allow continuous and longterm monitoring of human joint motion in everyday setting. The proposed device was benchmarked against mechanical goniometer and optical based motion capture system to validate its performance. From the empirical results, it has been proven that this design can be use as a robust and effective wearable joint monitoring device.

  14. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  15. Wrist joint assembly

    NASA Technical Reports Server (NTRS)

    Kersten, L.; Johnson, J. D. (Inventor)

    1978-01-01

    A wrist joint assembly is provided for use with a mechanical manipulator arm for finely positioning an end-effector carried by the wrist joint on the terminal end of the manipulator arm. The wrist joint assembly is pivotable about a first axis to produce a yaw motion, a second axis is to produce a pitch motion, and a third axis to produce a roll motion. The wrist joint assembly includes a disk segment affixed to the terminal end of the manipulator arm and a first housing member, a second housing member, and a third housing member. The third housing member and the mechanical end-effector are moved in the yaw, pitch, and roll motion. Drive means are provided for rotating each of the housings about their respective axis which includes a cluster of miniature motors having spur gears carried on the output drive shaft which mesh with a center drive gear affixed on the housing to be rotated.

  16. Design of Revolute Joints for In-Mold Assembly Using Insert Molding.

    PubMed

    Ananthanarayanan, Arvind; Ehrlich, Leicester; Desai, Jaydev P; Gupta, Satyandra K

    2011-12-01

    Creating highly articulated miniature structures requires assembling a large number of small parts. This is a very challenging task and increases cost of mechanical assemblies. Insert molding presents the possibility of creating a highly articulated structure in a single molding step. This can be accomplished by placing multiple metallic bearings in the mold and injecting plastic on top of them. In theory, this idea can generate a multi degree of freedom structures in just one processing step without requiring any post molding assembly operations. However, the polymer material has a tendency to shrink on top of the metal bearings and hence jam the joints. Hence, until now insert molding has not been used to create articulated structures. This paper presents a theoretical model for estimating the extent of joint jamming that occurs due to the shrinkage of the polymer on top of the metal bearings. The level of joint jamming is seen as the effective torque needed to overcome the friction in the revolute joints formed by insert molding. We then use this model to select the optimum design parameters which can be used to fabricate functional, highly articulating assemblies while meeting manufacturing constraints. Our analysis shows that the strength of weld-lines formed during the in-mold assembly process play a significant role in determining the minimum joint dimensions necessary for fabricating functional revolute joints. We have used the models and methods described in this paper to successfully fabricate the structure for a minimally invasive medical robot prototype with potential applications in neurosurgery. To the best of our knowledge, this is the first demonstration of building an articulated structure with multiple degrees of freedom using insert molding.

  17. Active and passive characteristics of muscle tone and their relationship to models of subluxation/joint dysfunction

    PubMed Central

    Knutson, Gary A.; Owens, Edward F.

    2003-01-01

    The relationship of muscles to the causes and effects of the pathophysiologic entity referred to as chiropractic subluxation or joint dysfunction is critical. Part I of this paper reviewed the complexities of skeletal muscle in regards to anatomy, active and passive tone, detection of muscle tone, neurophysiology, and how muscle function fits into a variety of subluxation/joint dysfunction models. The concluding part of the review culminates in a hypothesis to describe and explain varying degrees of muscle tone that may be encountered clinically. It is hoped that knowledge of the differing levels of muscle tone and their causes will help the clinician to better determine the underlying cause of a neuromusculoskeletal problem allowing application of necessary and proper intervention.

  18. Quality assurance, an administrative means to a managerial end: Part IV.

    PubMed

    Clark, G B

    1992-01-01

    This is the fourth and final part of a series of articles on laboratory quality surveillance. Part I addressed the historical background of medical quality assurance. Part II covered surveillance guidelines of the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) and the College of American Pathologists with emphasis on quality assurance (QA) and the ten-step process. Part III focused on the JCAHO transition from QA to quality assessment and improvement. Part IV concludes the series by discussing the systematic identification of quality indicators in the total quality management and continuous quality improvement environment.

  19. Product evaluation : Ruscoe 983 joint sealant

    DOT National Transportation Integrated Search

    1986-07-10

    This report contains a product evaluation of Ruscoe's 983 joint sealant. Ruscoe 983 is an asphalt base single compound joint sealant. It contains an aluminum fortified adhesive and is designed for use on highway expansion joints, bridge joints, and r...

  20. Measurement of complex joint trajectories using slice-to-volume 2D/3D registration and cine MR

    NASA Astrophysics Data System (ADS)

    Bloch, C.; Figl, M.; Gendrin, C.; Weber, C.; Unger, E.; Aldrian, S.; Birkfellner, W.

    2010-02-01

    A method for studying the in vivo kinematics of complex joints is presented. It is based on automatic fusion of single slice cine MR images capturing the dynamics and a static MR volume. With the joint at rest the 3D scan is taken. In the data the anatomical compartments are identified and segmented resulting in a 3D volume of each individual part. In each of the cine MR images the joint parts are segmented and their pose and position are derived using a 2D/3D slice-to-volume registration to the volumes. The method is tested on the carpal joint because of its complexity and the small but complex motion of its compartments. For a first study a human cadaver hand was scanned and the method was evaluated with artificially generated slice images. Starting from random initial positions of about 5 mm translational and 12° rotational deviation, 70 to 90 % of the registrations converged successfully to a deviation better than 0.5 mm and 5°. First evaluations using real data from a cine MR were promising. The feasibility of the method was demonstrated. However we experienced difficulties with the segmentation of the cine MR images. We therefore plan to examine different parameters for the image acquisition in future studies.

  1. Gene-expression changes in knee-joint tissues with aging and menopause: implications for the joint as an organ

    PubMed Central

    Rollick, Natalie C; Lemmex, Devin B; Ono, Yohei; Reno, Carol R; Hart, David A; Lo, Ian KY; Thornton, Gail M

    2018-01-01

    Background When considering the “joint as an organ”, the tissues in a joint act as complementary components of an organ, and the “set point” is the cellular activity for homeostasis of the joint tissues. Even in the absence of injury, joint tissues have adaptive responses to processes, like aging and menopause, which result in changes to the set point. Purpose The purpose of this study in a preclinical model was to investigate age-related and menopause-related changes in knee-joint tissues with the hypothesis that tissues will change in unique ways that reflect their differing contributions to maintaining joint function (as measured by joint laxity) and the differing processes of aging and menopause. Methods Rabbit knee-joint tissues from three groups were evaluated: young adult (gene expression, n=8; joint laxity, n=7; water content, n=8), aging adult (gene expression, n=6; joint laxity, n=7; water content, n=5), and menopausal adult (gene expression, n=8; joint laxity, n=7; water content, n=8). Surgical menopause was induced with ovariohysterectomy surgery and gene expression was assessed using reverse-transcription quantitative polymerase chain reaction. Results Aging resulted in changes to 37 of the 150 gene–tissue combinations evaluated, and menopause resulted in changes to 39 of the 150. Despite the similar number of changes, only eleven changes were the same in both aging and menopause. No differences in joint laxity were detected comparing young adult rabbits with aging adult rabbits or with menopausal adult rabbits. Conclusion Aging and menopause affected the gene-expression patterns of the tissues of the knee joint differently, suggesting unique changes to the set point of the knee. Interestingly, aging and menopause did not affect knee-joint laxity, suggesting that joint function was maintained, despite changes in gene expression. Taken together, these findings support the theory of the joint as an organ where the tissues of the joint adapt to

  2. Cost Minimization for Joint Energy Management and Production Scheduling Using Particle Swarm Optimization

    NASA Astrophysics Data System (ADS)

    Shah, Rahul H.

    Production costs account for the largest share of the overall cost of manufacturing facilities. With the U.S. industrial sector becoming more and more competitive, manufacturers are looking for more cost and resource efficient working practices. Operations management and production planning have shown their capability to dramatically reduce manufacturing costs and increase system robustness. When implementing operations related decision making and planning, two fields that have shown to be most effective are maintenance and energy. Unfortunately, the current research that integrates both is limited. Additionally, these studies fail to consider parameter domains and optimization on joint energy and maintenance driven production planning. Accordingly, production planning methodology that considers maintenance and energy is investigated. Two models are presented to achieve well-rounded operating strategy. The first is a joint energy and maintenance production scheduling model. The second is a cost per part model considering maintenance, energy, and production. The proposed methodology will involve a Time-of-Use electricity demand response program, buffer and holding capacity, station reliability, production rate, station rated power, and more. In practice, the scheduling problem can be used to determine a joint energy, maintenance, and production schedule. Meanwhile, the cost per part model can be used to: (1) test the sensitivity of the obtained optimal production schedule and its corresponding savings by varying key production system parameters; and (2) to determine optimal system parameter combinations when using the joint energy, maintenance, and production planning model. Additionally, a factor analysis on the system parameters is conducted and the corresponding performance of the production schedule under variable parameter conditions, is evaluated. Also, parameter optimization guidelines that incorporate maintenance and energy parameter decision making in the

  3. Effect of a 6-week dynamic neuromuscular training programme on ankle joint function: A Case report.

    PubMed

    O'Driscoll, Jeremiah; Kerin, Fearghal; Delahunt, Eamonn

    2011-06-09

    Ankle joint sprain and the subsequent development of chronic ankle instability (CAI) are commonly encountered by clinicians involved in the treatment and rehabilitation of musculoskeletal injuries. It has recently been advocated that ankle joint post-sprain rehabilitation protocols should incorporate dynamic neuromuscular training to enhance ankle joint sensorimotor capabilities. To date no studies have reported on the effects of dynamic neuromuscular training on ankle joint positioning during landing from a jump, which has been reported as one of the primary injury mechanisms for ankle joint sprain. This case report details the effects of a 6-week dynamic neuromuscular training programme on ankle joint function in an athlete with CAI. The athlete took part in a progressive 6-week dynamic neuromuscular training programme which incorporated postural stability, strengthening, plyometric, and speed/agility drills. The outcome measures chosen to assess for interventional efficacy were: 1 Cumberland Ankle Instability Tool (CAIT) scores, 2 Star Excursion Balance Test (SEBT) reach distances, 3 ankle joint plantar flexion during drop landing and drop vertical jumping, and 4 ground reaction forces (GRFs) during walking. CAIT and SEBT scores improved following participation in the programme. The angle of ankle joint plantar flexion decreased at the point of initial contact during the drop landing and drop vertical jumping tasks, indicating that the ankle joint was in a less vulnerable position upon landing following participation in the programme. Furthermore, GRFs were reduced whilst walking post-intervention. The 6-week dynamic neuromuscular training programme improved parameters of ankle joint sensorimotor control in an athlete with CAI. Further research is now required in a larger cohort of subjects to determine the effects of neuromuscular training on ankle joint injury risk factors.

  4. Manual treatment effects to the upper cervical apophysial joints before, during, and after endotracheal anesthesia: a placebo-controlled comparison.

    PubMed

    Buchmann, Johannes; Wende, Klaus; Kundt, Guenther; Haessler, Frank

    2005-04-01

    In this preliminary, placebo-controlled clinical trial, two different manual treatments were compared, spinal manipulation and postisometric relaxation, for dysfunctional motion segments of the upper cervical spinal column. The influence of the muscular portion on the joint-play restriction of a motion segment can be ignored in anesthesia, and the manual evaluation of this joint-play restriction must be focused on nonmuscular structures. By retesting in anesthesia, it is possible to examine whether mobilization and manipulation affect exclusively the muscular structures or also affect the other parts of the motion segment. Conclusions can be drawn about the superiority of one or both treatments and about the structural basis of the restricted joint play and its palpation. A total of 26 inpatients at the surgical or orthopedic department of the University of Rostock were examined manually at four testing times: before and after manual treatment, in anesthesia, and within 24 hrs of completing anesthesia. They were randomized into three groups: postisometric relaxation (mobilization), spinal manipulation (thrust technique), and placebo. A highly significant effect for both treatments was found posttherapeutically (P < 0.01) but not for placebo. In anesthesia, the treatment effect of spinal manipulation was further significant (P < 0.01) when compared with placebo. For postisometric relaxation, however, it was not (P = 0.160). A significant difference between spinal manipulation and postisometric relaxation was not found in anesthesia (P = 0.137). The treatment effect postnarcotically was further significant when compared with placebo only for spinal manipulation (P = 0.011). Both treatments are superior to placebo. Postisometric relaxation seems to affect mainly the muscular parts of the treated segments and less so the other parts, such as the joint capsule or the segmental affiliated ligaments and fascia. Spinal manipulation seems to influence all other segmental

  5. Knee joint mobilization reduces secondary mechanical hyperalgesia induced by capsaicin injection into the ankle joint.

    PubMed

    Sluka, K A; Wright, A

    2001-01-01

    Joint mobilization is a treatment approach commonly used by physical therapists for the management of a variety of painful conditions. However, the clinical effectiveness when compared to placebo and the neurophysiological mechanism of action are not known. The purpose of this study was to establish that application of a manual therapy technique will produce antihyperalgesia in an animal model of joint inflammation and that the antihyperalgesia produced by joint mobilization depends on the time of treatment application. Capsaicin (0.2%, 50 microl) was injected into the lateral aspect of the left ankle joint and mechanical withdrawal threshold assessed before and after capsaicin injection in Sprague-Dawley rats. Joint mobilization of the ipsilateral knee joint was performed 2 h after capsaicin injection for a total of 3 min, 9 min or 15 min under halothane anaesthesia. Control groups included animals that received halothane for the same time as the group that received joint mobilization and those whose limbs were held for the same duration as the mobilization (no halothane). Capsaicin resulted in a decreased mechanical withdrawal threshold by 2 h after injection that was maintained through 4 h. Both 9 and 15 min of mobilization, but not 3 min of mobilization, increased the withdrawal threshold to mechanical stimuli to baseline values when compared with control groups. The antihyperalgesic effect of joint mobilization lasted 30 min. Thus, joint mobilization (9 or 15 min duration) produces a significant reversal of secondary mechanical hyperalgesia induced by intra-articular injection of capsaicin. Copyright 2001 European Federation of Chapters of the International Association for the Study of Pain.

  6. Glass Masonry - Experimental Verification of Bed Joint under Shear

    NASA Astrophysics Data System (ADS)

    Fíla, J.; Eliášová, M.; Sokol, Z.

    2017-10-01

    Glass is considered as a traditional material for building industry but was mostly used for glazing of the windows. At present, glass is an integral part of contemporary architecture where glass structural elements such as beams, stairs, railing ribs or columns became popular in the last two decades. However, using glass as structural material started at the beginning of 20th century, when masonry from hollow glass blocks were used. Using solid glass brick is very rare and only a few structures with solid glass bricks walls have been built in the last years. Pillars and walls made from solid glass bricks are mainly loaded by compression and/or bending from the eccentricity of vertical load or wind load. Due to high compressive strength of glass, the limiting factor of the glass masonry is the joint between the glass bricks as the smooth surface requires another type of mortar / glue compared to traditional masonry. Shear resistance and failure modes of brick bed joint was determined during series of tests using various mortars, two types of surface treatment and different thickness of the mortar joint. Shear tests were completed by small scale tests for mortar - determination of flexural and compressive strength of hardened mortar.

  7. Adjustable bias column end joint assembly

    NASA Technical Reports Server (NTRS)

    Wallsom, Richard E. (Inventor); Bush, Harold G. (Inventor)

    1994-01-01

    An adjustable mechanical end joint system for connecting structural column elements and eliminating the possibility of free movement between joint halves during loading or vibration has a node joint body having a cylindrical engaging end and a column end body having a cylindrical engaging end. The column end joint body has a compressible preload mechanism and plunger means housed therein. The compressible preload mechanism may be adjusted from the exterior of the column end joint body through a port.

  8. Arch structure is associated with unique joint work, relative joint contributions and stiffness during landing.

    PubMed

    Powell, Douglas W; Queen, Robin M; Williams, D S Blaise

    2016-10-01

    To examine lower extremity joint contributions to a landing task in high-(HA) and low-arched (LA) female athletes by quantifying vertical stiffness, joint work and relative joint contributions to landing. Twenty healthy female recreational athletes (10 HA and 10 LA) performed five barefoot drop landings from a height of 30cm. Three-dimensional kinematics (240Hz) and ground reaction forces (960Hz) were recorded simultaneously. Vertical stiffness, joint work values and relative joint work values were calculated using Visual 3D and MatLab. HA athletes had significantly greater vertical stiffness compared to LA athletes (p=0.013). Though no differences in ankle joint work were observed (p=0.252), HA athletes had smaller magnitudes of knee (p=0.046), hip (p=0.019) and total lower extremity joint work values (p=0.016) compared to LA athletes. HA athletes had greater relative contributions of the ankle (p=0.032) and smaller relative contributions of the hip (p=0.049) compared to LA athletes. No differences in relative contributions of the knee were observed (p=0.255). These findings demonstrate that aberrant foot structure is associated with unique contributions of lower extremity joints to load attenuation during landing. These data may provide insight into the unique injury mechanisms associated with arch height in female athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Dissimilar metals joint evaluation

    NASA Technical Reports Server (NTRS)

    Wakefield, M. E.; Apodaca, L. E.

    1974-01-01

    Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

  10. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  11. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  12. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  13. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  14. Padalka and Polansky in the Node 1 during Joint Operations

    NASA Image and Video Library

    2009-07-21

    S127-E-007430 (21 July 2009) --- Astronaut Mark Polansky (right) and Russian Federal Space Agency cosmonaut Gennady Padalka take a break from a busy agenda onboard the International Space Station on the eve of the third of five spacewalks scheduled as part of more than a week's worth of joint activities for Endeavour and ISS crewmembers. Polansky is STS-127 commander, and Padalka is the station commander.

  15. Polansky and Padalka in the Node 1 during Joint Operations

    NASA Image and Video Library

    2009-07-21

    S127-E-007453 (21 July 2009) --- Astronaut Mark Polansky (left) and Russian Federal Space Agency cosmonaut Gennady Padalka take a break from a busy agenda onboard the International Space Station on the eve of the third of five spacewalks scheduled as part of more than a week's worth of joint activities for Endeavour and ISS crewmembers. Polansky is STS-127 commander, and Padalka is the station commander.

  16. The contribution of quasi-joint stiffness of the ankle joint to gait in patients with hemiparesis.

    PubMed

    Sekiguchi, Yusuke; Muraki, Takayuki; Kuramatsu, Yuko; Furusawa, Yoshihito; Izumi, Shin-Ichi

    2012-06-01

    The role of ankle joint stiffness during gait in patients with hemiparesis has not been clarified. The purpose of this study was to determine the contribution of quasi-joint stiffness of the ankle joint to spatiotemporal and kinetic parameters regarding gait in patients with hemiparesis due to brain tumor or stroke and healthy individuals. Spatiotemporal and kinetic parameters regarding gait in twelve patients with hemiparesis due to brain tumor or stroke and nine healthy individuals were measured with a 3-dimensional motion analysis system. Quasi-joint stiffness was calculated from the slope of the linear regression of the moment-angle curve of the ankle joint during the second rocker. There was no significant difference in quasi-joint stiffness among both sides of patients and the right side of controls. Quasi-joint stiffness on the paretic side of patients with hemiparesis positively correlated with maximal ankle power (r=0.73, P<0.01) and gait speed (r=0.66, P<0.05). In contrast, quasi-joint stiffness in controls negatively correlated with maximal ankle power (r=-0.73, P<0.05) and gait speed (r=-0.76, P<0.05). Our findings suggested that ankle power during gait might be generated by increasing quasi-joint stiffness in patients with hemiparesis. In contrast, healthy individuals might decrease quasi-joint stiffness to avoid deceleration of forward tilt of the tibia. Our findings might be useful for selecting treatment for increased ankle stiffness due to contracture and spasticity in patients with hemiparesis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Double slotted socket spherical joint

    DOEpatents

    Bieg, Lothar F.; Benavides, Gilbert L.

    2001-05-22

    A new class of spherical joints is disclosed. These spherical joints are capable of extremely large angular displacements (full cone angles in excess of 270.degree.), while exhibiting no singularities or dead spots in their range of motion. These joints can improve or simplify a wide range of mechanical devices.

  18. Role of hormones in cartilage and joint metabolism: understanding an unhealthy metabolic phenotype in osteoarthritis.

    PubMed

    Bay-Jensen, Anne C; Slagboom, Eline; Chen-An, Pingping; Alexandersen, Peter; Qvist, Per; Christiansen, Claus; Meulenbelt, Ingrid; Karsdal, Morten A

    2013-05-01

    Joint health is affected by local and systemic hormones. It is well accepted that systemic factors regulate the metabolism of joint tissues, and that substantial cross-talk between tissues actively contributes to homeostasis. In the current review, we try to define a subtype of osteoarthritis (OA), metabolic OA, which is dependent on an unhealthy phenotype. Peer-reviewed research articles and reviews were reviewed and summarized. Only literature readily available online, either by download or by purchase order, was included. OA is the most common joint disease and is more common in women after menopause. OA is a disease that affects the whole joint, including cartilage, subchondral bone, synovium, tendons, and muscles. The clinical endpoints of OA are pain and joint space narrowing, which is characterized by cartilage erosion and subchondral sclerosis, suggesting that cartilage is a central tissue of joint health. Thus, the joint, more specifically the cartilage, may be considered a target of endocrine function in addition to the well-described traditional risk factors of disease initiation and progression such as long-term loading of the joint due to obesity. Metabolic syndrome affects a range of tissues and may in part be molecularly described as a dysregulation of cytokines, adipokines, and hormones (e.g., estrogen and thyroid hormone). Consequently, metabolic imbalance may both directly and indirectly influence joint health and cartilage turnover, altering the progression of diseases such as OA. There is substantial evidence for a connection between metabolic health and development of OA. We propose that more focus be directed to understanding this connection to improve the management of menopausal health and associated comorbidities.

  19. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce-Part 2: reliability and application to multiple joints of a standardised consensus-based scoring system

    PubMed Central

    Terslev, Lene; Naredo, Esperanza; Aegerter, Philippe; Wakefield, Richard J; Backhaus, Marina; Balint, Peter; Bruyn, George A W; Iagnocco, Annamaria; Jousse-Joulin, Sandrine; Schmidt, Wolfgang A; Szkudlarek, Marcin; Conaghan, Philip G; Filippucci, Emilio

    2017-01-01

    Objectives To test the reliability of new ultrasound (US) definitions and quantification of synovial hypertrophy (SH) and power Doppler (PD) signal, separately and in combination, in a range of joints in patients with rheumatoid arthritis (RA) using the European League Against Rheumatisms–Outcomes Measures in Rheumatology (EULAR-OMERACT) combined score for PD and SH. Methods A stepwise approach was used: (1) scoring static images of metacarpophalangeal (MCP) joints in a web-based exercise and subsequently when scanning patients; (2) scoring static images of wrist, proximal interphalangeal joints, knee and metatarsophalangeal joints in a web-based exercise and subsequently when scanning patients using different acquisitions (standardised vs usual practice). For reliability, kappa coefficients (κ) were used. Results Scoring MCP joints in static images showed substantial intraobserver variability but good to excellent interobserver reliability. In patients, intraobserver reliability was the same for the two acquisition methods. Interobserver reliability for SH (κ=0.87) and PD (κ=0.79) and the EULAR-OMERACT combined score (κ=0.86) were better when using a ‘standardised’ scan. For the other joints, the intraobserver reliability was excellent in static images for all scores (κ=0.8–0.97) and the interobserver reliability marginally lower. When using standardised scanning in patients, the intraobserver was good (κ=0.64 for SH and the EULAR-OMERACT combined score, 0.66 for PD) and the interobserver reliability was also good especially for PD (κ range=0.41–0.92). Conclusion The EULAR-OMERACT score demonstrated moderate-good reliability in MCP joints using a standardised scan and is equally applicable in non-MCP joints. This scoring system should underpin improved reliability and consequently the responsiveness of US in RA clinical trials. PMID:28948984

  20. Clinical synovitis in a particular joint is associated with progression of erosions and joint space narrowing in that same joint, but not in patients initially treated with infliximab.

    PubMed

    Klarenbeek, N B; Güler-Yüksel, M; van der Heijde, D M F M; Hulsmans, H M J; Kerstens, P J S M; Molenaar, T H E; de Sonnaville, P B J; Huizinga, T W J; Dijkmans, B A C; Allaart, C F

    2010-12-01

    To assess the relationship between joint tenderness, swelling and joint damage progression in individual joints and to evaluate the influence of treatment on these relationships. First-year data of the Behandel Strategieën (BeSt) study were used, in which patients recently diagnosed as having rheumatoid arthritis (RA) were randomly assigned into four different treatment strategies. Baseline and 1-year x-rays of the hands and feet were assessed using the Sharp-van der Heijde score (SHS). With generalised estimating equations, 3-monthly assessments of tender and swollen joints of year 1 were related to erosion progression, joint space narrowing (JSN) progression and total SHS progression at the individual joint level (definition > 0.5 SHS units) in year 1, corrected for potential confounders and within-patient correlation for multiple joints per patient. During year 1, 59% of all 13 959 joints analysed were ever tender and 45% ever swollen, 2.1% showed erosion progression, 1.9% JSN progression and 3.6% SHS progression. Swelling and tenderness were both independently associated with erosion and JSN progression with comparable OR, although with higher OR in the hands than in the feet. Local swelling and tenderness were not associated with local damage progression in patients initially treated with infliximab. Clinical signs of synovitis are associated with erosion and JSN progression in individual joints after 1 year in RA. A disconnect between synovitis and joint damage progression was observed at joint level in patients who were treated with methotrexate and infliximab as initial treatment, confirming the disconnect between synovitis and the development of joint damage in tumour necrosis factor blockers seen at patient level.

  1. Sacroiliac joint pain - aftercare

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000610.htm Sacroiliac joint pain - aftercare To use the sharing features on this page, please enable JavaScript. The sacroiliac joint (SIJ) is a term used to describe ...

  2. Metacarpophalangeal joint arthroscopy: indications revisited.

    PubMed

    Choi, Alexander K Y; Chow, Esther C S; Ho, P C; Chow, Y Y

    2011-08-01

    Arthroscopic surgery has become the gold standard for the diagnosis and treatment of major joint disorders. With advancement in arthroscopic technique, arthroscopy has become feasible in most human joints, even those as small as the finger joints. The metacarpophalangeal joint (MCPJ) can become spacious with simple traction, the intra-articular anatomy is simple, and its major structures can be easily visualized and identified. However, MCPJ arthroscopy has never been popular. This article describes our experience with MCPJ arthroscopy and seeks to establish its role in clinical practice. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Perceptions and misconceptions regarding the Joint Commission's view of quality monitoring.

    PubMed

    Patterson, C H

    1989-10-01

    The Joint Commission recently has revised its hospital standards for infection control to reflect more accurately current state-of-the-art practices. In addition, the Joint Commission's Agenda for Change initiatives include the development of clinical indicators; one of the topics that will be included in those clinical indicator sets will be infection control. How the hospital chooses to organize itself to conduct the historically required monitoring and evaluation of clinical patient care currently required by the standards of the Joint Commission is at the option of the hospital. How the hospital will organize and collect data specific to infection control indicators yet to be developed by the Joint Commission has not been determined and will not be defined until specific research and development projects are completed. The hospital is expected to have in place infection prevention, surveillance, and control programs; it also is expected to have in place a quality assurance program that focuses not only on solving identified problems but also on the improvement of patient care quality. How the hospitals organize and/or integrate these activities is also at its option. It is expected that qualified professionals will direct and enforce infection prevention, surveillance, and control practices; indicators for infection control can provide data that will help assess the relative success of those practices and activities. The Joint Commission is not developing the capability to judge, on its own part, the actual quality of care provided by an organization seeking accreditation. Rather, the Joint Commission is committed to developing more accurate means to evaluate the structures, processes, and outcomes of diagnosis and treatment activities, as well as their interrelationships. Clinical excellence is supported by quality in the organizational environment and the managerial and leadership contexts within which patient care is delivered. Both clinical and

  4. Joint Attention in Autism: Teaching Smiling Coordinated with Gaze to Respond to Joint Attention Bids

    ERIC Educational Resources Information Center

    Krstovska-Guerrero, Ivana; Jones, Emily A.

    2013-01-01

    Children with autism demonstrate early deficits in joint attention and expressions of affect. Interventions to teach joint attention have addressed gaze behavior, gestures, and vocalizations, but have not specifically taught an expression of positive affect such as smiling that tends to occur during joint attention interactions. Intervention was…

  5. Sacroiliac joint tuberculosis: surgical management by posterior open-window focal debridement and joint fusion.

    PubMed

    Zhu, Guo; Jiang, Li-Yuan; Yi, Zhang; Ping, Li; Duan, Chun-Yue; Yong, Cao; Liu, Jin-Yang; Hu, Jian-Zhong

    2017-11-29

    Sacroiliac joint tuberculosis(SJT) is relatively uncommon, but it may cause severe sacroiliac joint destruction and functional disorder. Few studies in the literature have been presented on SJT, reports of surgical treatment for SJT are even fewer. In this study, we retrospectively reviewed surgical management of patients with severe SJT of 3 different types and proposed to reveal the clinical manifestations and features and aim to determine the efficiency and security of such surgical treatment. We reviewed 17 patients with severe SJT of 3 different types who underwent posterior open-window focal debridement and bone graft for joint fusion. Among them,five patients with anterior sacral abscess had anterior abscess curettage before debridement. Two patients with lumbar vertebral tuberculosis received one-stage posterior tuberculous debridement, interbody fusion and instrumentation. Follow-up was performed 36 months (26 to 45 months) using the following parameters: erythrocyte sedimentation rate(ESR), status of joint bony fusion on CT scan, visual analogue scale (VAS) and the Oswestry Disability Index (ODI). Buttock pain and low back pain were progressively relieved with time. 6 months later, pain was not obvious, and ESR resumed to normal levels within 3 months. Solid fusion of the sacroiliac joint occurred within 12 months in all cases. No complications or recurrence occurred. At final follow-up, all patients had no pain or only minimal discomfort over the affected joint and almost complete functional recovery. Posterior open-window focal debridement and joint fusion is an efficient and secure surgical method to treat severe SJT. If there is an abscess in the front of the sacroiliac joint, anterior abscess curettage should be performed as a supplement.

  6. Numerical analysis of dynamic behavior of pre-stressed shape memory alloy concrete beam-column joints

    NASA Astrophysics Data System (ADS)

    Yan, S.; Xiao, Z. F.; Lin, M. Y.; Niu, J.

    2018-04-01

    Beam-column joints are important parts of a main frame structure. Mechanical properties of beam-column joints have a great influence on dynamic performances of the frame structure. Shape memory alloy (SMA) as a new type of intelligent metal materials has wide applications in civil engineering. The paper aims at proposing a novel beam-column joint reinforced with pre-stressed SMA tendons to increase its dynamic performance. Based on the finite element analysis (FEA) software ABAQUS, a numerical simulation for 6 beam-column scaled models considering different SMA reinforcement ratios and pre-stress levels was performed, focusing on bearing capacities, energy-dissipation and self-centering capacities, etc. These models were numerically tested under a pseudo-static load on the beam end, companying a constant vertical compressive load on the top of the column. The numerical results show that the proposed SMA-reinforced joint has a significantly increased bearing capacity and a good self-centering capability after unloading even though the energy-dissipation capacity becomes smaller due the less residual deformation. The concept and mechanism of the novel joint can be used as an important reference for civil engineering applications.

  7. Jointness for the Rest of Us: Reforming Joint Professional Development

    DTIC Science & Technology

    2016-06-10

    where service capabilities are combined to maximize effectiveness while minimizing vulnerabilities. However, despite the passage of thirty years ...staff of the Joint Advance Warfighting School and the Joint Forces Staff College for their support during the academic year . Special thanks to my...seminar faculty Colonel Chris Rogers, Dr. Mike Pavlec, and Captain Miguel “Boo” Peko for the lessons and laughs that have made this year so enjoyable

  8. 41. DISCOVERY, SEARCH, AND COMMUNICATION OF TEXTUAL KNOWLEDGE RESOURCES IN DISTRIBUTED SYSTEMS a. Discovering and Utilizing Knowledge Sources for Metasearch Knowledge Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zamora, Antonio

    Advanced Natural Language Processing Tools for Web Information Retrieval, Content Analysis, and Synthesis. The goal of this SBIR was to implement and evaluate several advanced Natural Language Processing (NLP) tools and techniques to enhance the precision and relevance of search results by analyzing and augmenting search queries and by helping to organize the search output obtained from heterogeneous databases and web pages containing textual information of interest to DOE and the scientific-technical user communities in general. The SBIR investigated 1) the incorporation of spelling checkers in search applications, 2) identification of significant phrases and concepts using a combination of linguisticmore » and statistical techniques, and 3) enhancement of the query interface and search retrieval results through the use of semantic resources, such as thesauri. A search program with a flexible query interface was developed to search reference databases with the objective of enhancing search results from web queries or queries of specialized search systems such as DOE's Information Bridge. The DOE ETDE/INIS Joint Thesaurus was processed to create a searchable database. Term frequencies and term co-occurrences were used to enhance the web information retrieval by providing algorithmically-derived objective criteria to organize relevant documents into clusters containing significant terms. A thesaurus provides an authoritative overview and classification of a field of knowledge. By organizing the results of a search using the thesaurus terminology, the output is more meaningful than when the results are just organized based on the terms that co-occur in the retrieved documents, some of which may not be significant. An attempt was made to take advantage of the hierarchy provided by broader and narrower terms, as well as other field-specific information in the thesauri. The search program uses linguistic morphological routines to find relevant entries regardless of

  9. 12 CFR 347.107 - Joint ventures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Joint ventures. 347.107 Section 347.107 Banks... INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly, acquires or holds an equity interest in a foreign organization that is a joint venture, and the bank or its...

  10. About the Joint Chiefs of Staff

    Science.gov Websites

    JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman J8 | Force Structure, Resources & Assessment Contact Joint Staff Structure Home : About About the Joint Chiefs of Staff Download the CJCS Historic Guide The Joint Chiefs of Staff consist of the Chairman

  11. Joint attention responses of children with autism spectrum disorder to simple versus complex music.

    PubMed

    Kalas, Amy

    2012-01-01

    Joint attention deficits are viewed as one of the earliest manifestations and most characteristic features of the social deficits in Autism Spectrum Disorder (ASD). The purpose of this study was to examine the effect of simple versus complex music on joint attention of children with ASD. Thirty children with a diagnosis of ASD participated in this study. Fifteen of the participants were diagnosed with severe ASD and 15 were diagnosed with mild/moderate ASD. Each participant took part in six, 10-minute individual music conditions (3 simple & 3 complex) over a 3-week period. Each condition was designed to elicit responses to joint attention. RESULTS indicated a statistically significant interaction between music modality and functioning level. Therefore, the effect of simple versus complex music was dependent on functioning level. Specifically, the Simple Music Condition was more effective in eliciting Responses to Joint Attention (RJA) for children diagnosed with severe ASD, whereas the Complex Music Condition was more effective in eliciting RJA for children diagnosed with mild/moderate ASD. The results of the present study indicate that for children in the severe range of functioning, music that is simple, with clear and predictable pattems, may be most effective in eliciting responses to bids for joint attention. On the contrary, for children in the mild/moderate range of functioning, music that is more complex and variable may be most effective in eliciting responses to bids for joint attention. These results demonstrate that careful manipulation of specific musical elements can help provide the optimal conditions for facilitating joint attention with children with ASD.

  12. 26 CFR 1.6015-1 - Relief from joint and several liability on a joint return.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... they claim losses attributable to H's limited partnership interest in Partnership A. In January 2006... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Relief from joint and several liability on a... joint and several liability on a joint return. (a) In general. (1) An individual who qualifies and...

  13. Large displacement spherical joint

    DOEpatents

    Bieg, Lothar F.; Benavides, Gilbert L.

    2002-01-01

    A new class of spherical joints has a very large accessible full cone angle, a property which is beneficial for a wide range of applications. Despite the large cone angles, these joints move freely without singularities.

  14. Finite element modelling of the articular disc behaviour of the temporo-mandibular joint under dynamic loads.

    PubMed

    Jaisson, Maxime; Lestriez, Philippe; Taiar, Redha; Debray, Karl

    2011-01-01

    The proposed biodynamic model of the articular disc joint has the ability to affect directly the complete chewing mechanism process and its related muscles defining its kinematics. When subjected to stresses from the mastication muscles, the disc absorbs one part and redistributes the other to become completely distorted. To develop a realistic model of this intricate joint a CT scan and MRI images from a patient were obtained to create sections (layers) and MRI images to create an anatomical joint CAD model, and its corresponding mesh element using a finite element method. The boundary conditions are described by the external forces applied to the joint model through a decomposition of the maximum muscular force developed by the same individual. In this study, the maximum force was operating at frequencies close to the actual chewing frequency measured through a cyclic loading condition. The reaction force at the glenoid fossa was found to be around 1035 N and is directly related to the frequency of indentation. It is also shown that over the years the areas of maximum stresses are located at the lateral portion of the disc and on its posterior rim. These forces can reach 13.2 MPa after a period of 32 seconds (s) at a frequency of 0.5 Hz. An important part of this study is to highlight resilience and the areas where stresses are at their maximum. This study provides a novel approach to improve the understanding of this complex joint, as well as to assess the different pathologies associated with the disc disease that would be difficult to study otherwise.

  15. Transition Plan For the Technology Demonstration of the Joint Network Defence and Management System (JNDMS)

    DTIC Science & Technology

    2009-11-01

    Technology Demonstration of the Joint Network Defence and Management System (JNDMS) Brett Trask; Novembre 2009. Dès le départ, nous avons mis au point le... 13 5.1 System Specification... 13 5.1.1 Scope ............................................................................................................. 13 5.2 Security

  16. Effect of a 6-week dynamic neuromuscular training programme on ankle joint function: A Case report

    PubMed Central

    2011-01-01

    Background Ankle joint sprain and the subsequent development of chronic ankle instability (CAI) are commonly encountered by clinicians involved in the treatment and rehabilitation of musculoskeletal injuries. It has recently been advocated that ankle joint post-sprain rehabilitation protocols should incorporate dynamic neuromuscular training to enhance ankle joint sensorimotor capabilities. To date no studies have reported on the effects of dynamic neuromuscular training on ankle joint positioning during landing from a jump, which has been reported as one of the primary injury mechanisms for ankle joint sprain. This case report details the effects of a 6-week dynamic neuromuscular training programme on ankle joint function in an athlete with CAI. Methods The athlete took part in a progressive 6-week dynamic neuromuscular training programme which incorporated postural stability, strengthening, plyometric, and speed/agility drills. The outcome measures chosen to assess for interventional efficacy were: [1] Cumberland Ankle Instability Tool (CAIT) scores, [2] Star Excursion Balance Test (SEBT) reach distances, [3] ankle joint plantar flexion during drop landing and drop vertical jumping, and [4] ground reaction forces (GRFs) during walking. Results CAIT and SEBT scores improved following participation in the programme. The angle of ankle joint plantar flexion decreased at the point of initial contact during the drop landing and drop vertical jumping tasks, indicating that the ankle joint was in a less vulnerable position upon landing following participation in the programme. Furthermore, GRFs were reduced whilst walking post-intervention. Conclusions The 6-week dynamic neuromuscular training programme improved parameters of ankle joint sensorimotor control in an athlete with CAI. Further research is now required in a larger cohort of subjects to determine the effects of neuromuscular training on ankle joint injury risk factors. PMID:21658224

  17. Spherical Joint Piston and Connecting Rod Developed

    NASA Technical Reports Server (NTRS)

    1996-01-01

    load symmetry, reduced bearing stresses, reduced running clearances, and reduced oil consumption. The spherical joint piston is a monolithic, squeeze-cast, fiber-reinforced aluminum piston. The connecting rod has a ball end that seats on a spherical saddle within the piston and is retained by a pair of aluminum bronze holder rings. The holder rings are secured by a threaded ring that mates with the piston. As part of the ongoing research and development activity, the Cummins Engine Company successfully completed a 100-hr test of the spherical joint piston and connecting rod at LE- 55 peak steady-state engine conditions. In addition, a 100-hr transient cycle test that varied engine conditions between LE-55 no-load and LE-55 full-load was successfully completed.

  18. Imaging and Analysis of Void-defects in Solder Joints Formed in Reduced Gravity using High-Resolution Computed Tomography

    NASA Technical Reports Server (NTRS)

    Easton, John W.; Struk, Peter M.; Rotella, Anthony

    2008-01-01

    As a part of efforts to develop an electronics repair capability for long duration space missions, techniques and materials for soldering components on a circuit board in reduced gravity must be developed. This paper presents results from testing solder joint formation in low gravity on a NASA Reduced Gravity Research Aircraft. The results presented include joints formed using eutectic tin-lead solder and one of the following fluxes: (1) a no-clean flux core, (2) a rosin flux core, and (3) a solid solder wire with external liquid no-clean flux. The solder joints are analyzed with a computed tomography (CT) technique which imaged the interior of the entire solder joint. This replaced an earlier technique that required the solder joint to be destructively ground down revealing a single plane which was subsequently analyzed. The CT analysis technique is described and results presented with implications for future testing as well as implications for the overall electronics repair effort discussed.

  19. Does Success Of Arthroscopic Laser Surgery In The Knee Joint Warrant Its Extension To "Non-Knee" Joints?

    NASA Astrophysics Data System (ADS)

    Smith, Chadwick F.; Johansen, W. Edward; Vangness, C. Thomas; Yamaguchi, Ken; McEleney, Emmett T.; Bales, Peter

    1987-03-01

    One of the authors has performed 162 arthroscopic laser surgeries in the knee joint without any major complication. Other investigators have recently proposed diagnostic arthroscopy and arthroscopic surgery for "non-knee" joints. The authors have proposed that arthroscopic laser surgery he extended to "non-knee" joints. The authors have performed arthroscopic laser surgery on "non-knee" joints of twelve cadavers. One of the authors have performed one successful arthroscopic surgery on a shoulder joint with only a minor, transient complication of subcutaneous emphysema. Is laser arthroscopic surgery safe and effective in "non-knee" joints? The evolving answer appears to be a qualified "Yes," which needs to be verified by a multicenter trial.

  20. Estimation of Time-Varying, Intrinsic and Reflex Dynamic Joint Stiffness during Movement. Application to the Ankle Joint

    PubMed Central

    Guarín, Diego L.; Kearney, Robert E.

    2017-01-01

    Dynamic joint stiffness determines the relation between joint position and torque, and plays a vital role in the control of posture and movement. Dynamic joint stiffness can be quantified during quasi-stationary conditions using disturbance experiments, where small position perturbations are applied to the joint and the torque response is recorded. Dynamic joint stiffness is composed of intrinsic and reflex mechanisms that act and change together, so that nonlinear, mathematical models and specialized system identification techniques are necessary to estimate their relative contributions to overall joint stiffness. Quasi-stationary experiments have demonstrated that dynamic joint stiffness is heavily modulated by joint position and voluntary torque. Consequently, during movement, when joint position and torque change rapidly, dynamic joint stiffness will be Time-Varying (TV). This paper introduces a new method to quantify the TV intrinsic and reflex components of dynamic joint stiffness during movement. The algorithm combines ensemble and deterministic approaches for estimation of TV systems; and uses a TV, parallel-cascade, nonlinear system identification technique to separate overall dynamic joint stiffness into intrinsic and reflex components from position and torque records. Simulation studies of a stiffness model, whose parameters varied with time as is expected during walking, demonstrated that the new algorithm accurately tracked the changes in dynamic joint stiffness using as little as 40 gait cycles. The method was also used to estimate the intrinsic and reflex dynamic ankle stiffness from an experiment with a healthy subject during which ankle movements were imposed while the subject maintained a constant muscle contraction. The method identified TV stiffness model parameters that predicted the measured torque very well, accounting for more than 95% of its variance. Moreover, both intrinsic and reflex dynamic stiffness were heavily modulated through the

  1. Is cannabis an effective treatment for joint pain?

    PubMed

    Miller, Richard J; Miller, Rachel E

    2017-01-01

    Cannabis has been used to treat pain for thousands of years. However, since the early part of the 20th century, laws restricting cannabis use have limited its evaluation using modern scientific criteria. Over the last decade, the situation has started to change because of the increased availability of cannabis in the United States for either medical or recreational purposes, making it important to provide the public with accurate information as to the effectiveness of the drug for joint pain among other indications. The major psychotropic component of cannabis is Δ9-tetrahydrocannabinol (THC), one of some 120 naturally occurring phytocannabinoids. Cannabidiol (CBD) is another molecule found in herbal cannabis in large amounts. Although CBD does not produce psychotropic effects, it has been shown to produce a variety of pharmacological effects. Hence, the overall effects of herbal cannabis represent the collective activity of THC, CBD and a number of minor components. The action of THC is mediated by two major G-protein coupled receptors, cannabinoid receptor type 1 (CB1) and CB2, and recent work has suggested that other targets may also exist. Arachidonic acid derived endocannabinoids are the normal physiological activators of the two cannabinoid receptors. Natural phytocannabinoids and synthetic derivatives have produced clear activity in a variety of models of joint pain in animals. These effects are the result of both inhibition of pain pathway signalling (mostly CB1) and anti-inflammatory effects (mostly CB2). There are also numerous anecdotal reports of the effectiveness of smoking cannabis for joint pain. Indeed, it is the largest medical request for the use of the drug. However, these reports generally do not extend to regulated clinical trials for rheumatic diseases. Nevertheless, the preclinical and human data that do exist indicate that the use of cannabis should be taken seriously as a potential treatment of joint pain.

  2. Latest trends in parts SEP susceptibility from heavy ions

    NASA Technical Reports Server (NTRS)

    Nichols, Donald K.; Smith, L. S.; Soli, George A.; Koga, R.; Kolasinski, W. A.

    1989-01-01

    JPL and Aerospace have collected a third set of heavy-ion single-event phenomena (SEP) test data since their last joint IEEE publications in December 1985 and December 1987. Trends in SEP susceptibility (e.g., soft errors and latchup) for state-of-the-art parts are presented. Results of the study indicate that hard technologies and unacceptably soft technologies can be flagged. In some instances, specific tested parts can be taken as candidates for key microprocessors or memories. As always with radiation test data, specific test data for qualified flight parts is recommended for critical applications.

  3. Hip and knee joints are more stabilized than driven during the stance phase of gait: an analysis of the 3D angle between joint moment and joint angular velocity.

    PubMed

    Dumas, R; Cheze, L

    2008-08-01

    Joint power is commonly used in orthopaedics, ergonomics or sports analysis but its clinical interpretation remains controversial. Some basic principles on muscle actions and energy transfer have been proposed in 2D. The decomposition of power on 3 axes, although questionable, allows the same analysis in 3D. However, these basic principles have been widely criticized, mainly because bi-articular muscles must be considered. This requires a more complex computation in order to determine how the individual muscle force contributes to drive the joint. Conversely, with simple 3D inverse dynamics, the analysis of both joint moment and angular velocity directions is essential to clarify when the joint moment can contribute or not to drive the joint. The present study evaluates the 3D angle between the joint moment and the joint angular velocity and investigates when the hip, knee and ankle joints are predominantly driven (angle close to 0 degrees and 180 degrees ) or stabilized (angle close to 90 degrees ) during gait. The 3D angle curves show that the three joints are never fully but only partially driven and that the hip and knee joints are mainly stabilized during the stance phase. The notion of stabilization should be further investigated, especially for subjects with motion disorders or prostheses.

  4. Swivel Joint For Liquid Nitrogen

    NASA Technical Reports Server (NTRS)

    Milner, James F.

    1988-01-01

    Swivel joint allows liquid-nitrogen pipe to rotate through angle of 100 degree with respect to mating pipe. Functions without cracking hard foam insulation on lines. Pipe joint rotates on disks so mechanical stress not transmitted to thick insulation on pipes. Inner disks ride on fixed outer disks. Disks help to seal pressurized liquid nitrogen flowing through joint.

  5. The Standard Joint Unit.

    PubMed

    Casajuana Kögel, Cristina; Balcells-Olivero, María Mercedes; López-Pelayo, Hugo; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Nutt, David John; Rehm, Jürgen; Gual, Antoni

    2017-07-01

    Reliable data on cannabis quantities is required to improve assessment of cannabis consumption for epidemiological analysis and clinical assessment, consequently a Standard Joint Unit (SJU) based on quantity of 9-Tetrahydrocannabinol (9-THC) has been established. Naturalistic study of a convenience sample recruited from February 2015-June 2016 in universities, leisure spaces, mental health services and cannabis clubs in Barcelona. Adults, reporting cannabis use in the last 60 days, without cognitive impairment or language barriers, answered a questionnaire on cannabis use and were asked to donate a joint to further determine their 9-THC and Cannabidiol (CBD) content. 492 participants donated 315 valid joints. Donators were on average 29 years old, mostly men (77%), single (75%), with at least secondary studies (73%) and in active employment (63%). Marijuana joints (N=232) contained a median of 6.56mg of 9-THC (Interquartile range-IQR=10,22) and 0.02mg of CBD (IQR=0.02); hashish joints (N=83) a median of 7.94mg of 9-THC (IQR=10,61) and 3.24mg of CBD (IQR=3.21). Participants rolled 4 joints per gram of cannabis and paid 5€ per gram (median values). Consistent 9-THC-content in joints lead to a SJU of 7mg of 9-THC, the integer number closest to the median values shared by both cannabis types. Independently if marijuana or hashish, 1 SJU = 1 joint = 0.25 g of cannabis = 7 mg of 9-THC. For CBD, only hashish SJU contained relevant levels. Similarly to the Standard Drink Unit for alcohol, the SJU is useful for clinical, epidemiological and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. 29 CFR Appendix to Part 1440 - FIFRA Arbitration Rules

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DATA DISPUTES Pt. 1440, App. Appendix to Part 1440—FIFRA Arbitration Rules Section 1 These rules shall apply as published in the Federal Register unless modified by FMCS. Sec. 2. Definitions For the purpose... Rules or filing a claim concerning joint development of data. (6) Compulsory arbitration means...

  7. 29 CFR Appendix to Part 1440 - FIFRA Arbitration Rules

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... DATA DISPUTES Pt. 1440, App. Appendix to Part 1440—FIFRA Arbitration Rules Section 1 These rules shall apply as published in the Federal Register unless modified by FMCS. Sec. 2. Definitions For the purpose... Rules or filing a claim concerning joint development of data. (6) Compulsory arbitration means...

  8. 29 CFR Appendix to Part 1440 - FIFRA Arbitration Rules

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... DATA DISPUTES Pt. 1440, App. Appendix to Part 1440—FIFRA Arbitration Rules Section 1 These rules shall apply as published in the Federal Register unless modified by FMCS. Sec. 2. Definitions For the purpose... Rules or filing a claim concerning joint development of data. (6) Compulsory arbitration means...

  9. 29 CFR Appendix to Part 1440 - FIFRA Arbitration Rules

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... DATA DISPUTES Pt. 1440, App. Appendix to Part 1440—FIFRA Arbitration Rules Section 1 These rules shall apply as published in the Federal Register unless modified by FMCS. Sec. 2. Definitions For the purpose... Rules or filing a claim concerning joint development of data. (6) Compulsory arbitration means...

  10. Temporo mandibular joint ankylosis.

    PubMed

    Vasconcelos, Belmiro Cavalcanti do Egito; Porto, Gabriela Granja; Bessa-Nogueira, Ricardo Viana

    2008-01-01

    Ankylosis may be defined as joint surfaces fusion. The treatment of temporomandibular joint ankylosis poses a significant challenge because of the high recurrence rate. The aim of this study is to report six cases treated by joint reconstruction, evaluate the results of these surgeries and review the literature. The sample in this retrospective study was obtained from the records of the university hospital, patients who had to undergo ankylosis treatment by alloplastic or autogenous graft between March 2001 and October 2005. Pre - and post-operative assessment included a throughout history and physical examination to determine the cause of ankylosis, the Maximum mouth opening (MMO), etiology and type of ankylosis, recurrence rate and presence of facial nerve paralysis. The mean MMO in the pre-operative period was 9.6 mm (0 mm to 17 mm) and in the post-operative period it was of 31.33 mm (14 mm to 41 mm), there was no facial nerve paralysis and there was recurrence in just one case. The joint reconstruction with alloplastic or autogenous grafts for the ankylosis treatment proved to be efficient in relation to the post-operative MMO, recurrence and joint function.

  11. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system.

    PubMed

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry(®) SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed.

  12. Unloading joints to treat osteoarthritis, including joint distraction.

    PubMed

    Lafeber, Floris P J G; Intema, Femke; Van Roermund, Peter M; Marijnissen, Anne C A

    2006-09-01

    Patients are increasingly becoming interested in nonpharmacologic approaches to manage their osteoarthritis. This review examines the recent literature on the potential beneficial effects of unloading joints in the treatment of osteoarthritis, with a focus on joint distraction. Mechanical factors are involved in the development and progression of osteoarthritis. If "loading" is a major cause in development and progression of osteoarthritis, then "unloading" may be able to prevent progression. There is evidence that unloading may be effective in reducing pain and slowing down structural damage. This review describes unloading by footwear and bracing (nonsurgical), unloading by osteotomy (surgical), and has a focus on unloading by joint distraction. Excellent reviews in all these three fields have been published over the past few years. Recent studies argue for the usefulness of a biomechanical approach to improve function and possibly reduce disease progression in osteoarthritis. To improve patient function and possibly reduce disease progression, a biomechanical approach should be considered in treating patients with osteoarthritis. Further research (appropriate high-quality clinical trials) and analysis (clinical as well as preclinical and fundamental) are still necessary, however, to understand, validate, and refine the different approaches of unloading to treat osteoarthritis.

  13. Joint design of QC-LDPC codes for coded cooperation system with joint iterative decoding

    NASA Astrophysics Data System (ADS)

    Zhang, Shunwai; Yang, Fengfan; Tang, Lei; Ejaz, Saqib; Luo, Lin; Maharaj, B. T.

    2016-03-01

    In this paper, we investigate joint design of quasi-cyclic low-density-parity-check (QC-LDPC) codes for coded cooperation system with joint iterative decoding in the destination. First, QC-LDPC codes based on the base matrix and exponent matrix are introduced, and then we describe two types of girth-4 cycles in QC-LDPC codes employed by the source and relay. In the equivalent parity-check matrix corresponding to the jointly designed QC-LDPC codes employed by the source and relay, all girth-4 cycles including both type I and type II are cancelled. Theoretical analysis and numerical simulations show that the jointly designed QC-LDPC coded cooperation well combines cooperation gain and channel coding gain, and outperforms the coded non-cooperation under the same conditions. Furthermore, the bit error rate performance of the coded cooperation employing jointly designed QC-LDPC codes is better than those of random LDPC codes and separately designed QC-LDPC codes over AWGN channels.

  14. Importance of dowels in transversal joints in concrete pavements

    NASA Astrophysics Data System (ADS)

    Grosek, Jiri; Chupik, Vladimir; Stryk, Josef; Brezina, Ilja

    2017-09-01

    Concrete pavements are designed for heavy loaded road structures. Their usage brings a number of specific issues. It is necessary to solve them all to ensure that concrete pavements will fulfil their function along the whole design period. One of these issues concerns dowels, which are located in transversal joints. Modelling of load, caused by heavy vehicles, with the use of the finite element method, provides valuable information about the stress condition of concrete pavement. The results of modelling can be verified by measurements or experiments in practice. Dowels and tie bars in jointed unreinforced concrete pavements and the importance of their correct placement, dimensions and material quality on pavement behaviour and lifespan were studied as a part of R&D projects of Technology Agency of the Czech Republic Nos. TA02031195 and TE01020168. The paper presents the experience from the modelling and performed experiments and makes conclusions which are important for the use in practice.

  15. Astronaut Stafford and Cosmonaut Leonov during joint crew training at JSC

    NASA Image and Video Library

    1975-02-24

    S75-21945 (24 Feb. 1975) --- Cosmonaut Aleksey A. Leonov (left) and astronaut Thomas P. Stafford take part in Apollo-Soyuz Test Project joint crew training in Building 35 at NASA's Johnson Space Center. They are commanders of their respective prime crews. The training session simulated the activities of the second day in Earth orbit. Stafford and Leonov are in the Docking Module mock-up.

  16. The joint venture alternative to mergers.

    PubMed

    Enders, R J

    1995-02-01

    However, while a joint venture may be "safe" from antitrust challenge, it is not without some practical difficulties, especially with respect to consolidating services at one location or jointly offering services provided at multiple facilities. These practical concerns include: 1. Who will exercise operational management of the joint venture? 2. How will the joint venture deal with different pricing for services that will be provided at multiple locations? 3. What criteria will be used to decide the location at which consolidated tertiary services will be offered? 4. In what circumstances can the joint venture be unwound, either in its entirety or as to discrete functions? When clinical services have been consolidated at one location, there is an appropriate concern by the other hospital that it will be unable to provide or re-enter the market for those services if the joint venture dissolves. These operational concerns, of course, are not addressed in the Consent Decree. Thus, even if a joint venture relationship survives antitrust scrutiny, the parties must still negotiate and resolve these operational issues in order for the joint venture to be viable.

  17. Bolted joints in graphite-epoxy composites

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1976-01-01

    All-graphite/epoxy laminates and hybrid graphite-glass/epoxy laminates were tested. The tests encompassed a range of geometries for each laminate pattern to cover the three basic failure modes - net section tension failure through the bolt hole, bearing and shearout. Static tensile and compressive loads were applied. A constant bolt diameter of 6.35 mm (0.25 in.) was used in the tests. The interaction of stress concentrations associated with multi-row bolted joints was investigated by testing single- and double-row bolted joints and open-hole specimens in tension. For tension loading, linear interaction was found to exist between the bearing stress reacted at a given bolt hole and the remaining tension stress running by that hole to be reacted elsewhere. The interaction under compressive loading was found to be non-linear. Comparative tests were run using single-lap bolted joints and double-lap joints with pin connection. Both of these joint types exhibited lower strengths than were demonstrated by the corresponding double-lap joints. The analysis methods developed here for single bolt joints are shown to be capable of predicting the behavior of multi-row joints.

  18. Space Station alpha joint bearing

    NASA Technical Reports Server (NTRS)

    Everman, Michael R.; Jones, P. Alan; Spencer, Porter A.

    1987-01-01

    Perhaps the most critical structural system aboard the Space Station is the Solar Alpha Rotary Joint which helps align the power generation system with the sun. The joint must provide structural support and controlled rotation to the outboard transverse booms as well as power and data transfer across the joint. The Solar Alpha Rotary Joint is composed of two transition sections and an integral, large diameter bearing. Alpha joint bearing design presents a particularly interesting problem because of its large size and need for high reliability, stiffness, and on orbit maintability. The discrete roller bearing developed is a novel refinement to cam follower technology. It offers thermal compensation and ease of on-orbit maintenance that are not found in conventional rolling element bearings. How the bearing design evolved is summarized. Driving requirements are reviewed, alternative concepts assessed, and the selected design is described.

  19. Geometric features of workspace and joint-space paths of 3D reaching movements.

    PubMed

    Klein Breteler, M D; Meulenbroek, R G; Gielen, S C

    1998-11-01

    The present study focuses on geometric features of workspace and joint-space paths of three-dimensional reaching movements. Twelve subjects repeatedly performed a three-segment, triangular-shaped movement pattern in an approximately 60 degrees tilted horizontal plane. Task variables elicited movement patterns that varied in position, rotational direction and speed. Trunk, arm, hand and finger-tip movements were recorded by means of a 3D motion-tracking system. Angular excursions of the shoulder and elbow joints were extracted from position data. Analyses of the shape of 3D workspace and joint-space paths focused on the extent to which the submovements were produced in a plane, and on the curvature of the central parts of the submovements. A systematic tendency to produce movements in a plane was found in addition to an increase of finger-tip path curvature with increasing speed. The findings are discussed in relation to the role of optimization principles in trajectory-formation models.

  20. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    PubMed

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  1. Reliability of a smartphone-based goniometer for knee joint goniometry.

    PubMed

    Ferriero, Giorgio; Vercelli, Stefano; Sartorio, Francesco; Muñoz Lasa, Susana; Ilieva, Elena; Brigatti, Elisa; Ruella, Carolina; Foti, Calogero

    2013-06-01

    The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.

  2. Phase 1 Program Joint Report

    NASA Technical Reports Server (NTRS)

    Nield, George C. (Editor); Vorobiev, Pavel Mikhailovich (Editor)

    1999-01-01

    This report consists of inputs from each of the Phase I Program Joint Working Groups. The Working Groups were tasked to describe the organizational structure and work processes that they used during the program, joint accomplishments, lessons learned, and applications to the International Space Station Program. This report is a top-level joint reference document that contains information of interest to both countries.

  3. Feature-extracted joint transform correlation.

    PubMed

    Alam, M S

    1995-12-10

    A new technique for real-time optical character recognition that uses a joint transform correlator is proposed. This technique employs feature-extracted patterns for the reference image to detect a wide range of characters in one step. The proposed technique significantly enhances the processing speed when compared with the presently available joint transform correlator architectures and shows feasibility for multichannel joint transform correlation.

  4. Cancer risk among patients with finger and hand joint and temporo-mandibular joint prostheses in Denmark.

    PubMed

    Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H

    1999-05-31

    The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.

  5. JointMMCC: Joint Maximum-Margin Classification and Clustering of Imaging Data

    PubMed Central

    Filipovych, Roman; Resnick, Susan M.; Davatzikos, Christos

    2012-01-01

    A number of conditions are characterized by pathologies that form continuous or nearly-continuous spectra spanning from the absence of pathology to very pronounced pathological changes (e.g., normal aging, Mild Cognitive Impairment, Alzheimer's). Moreover, diseases are often highly heterogeneous with a number of diagnostic subcategories or subconditions lying within the spectra (e.g., Autism Spectrum Disorder, schizophrenia). Discovering coherent subpopulations of subjects within the spectrum of pathological changes may further our understanding of diseases, and potentially identify subconditions that require alternative or modified treatment options. In this paper, we propose an approach that aims at identifying coherent subpopulations with respect to the underlying MRI in the scenario where the condition is heterogeneous and pathological changes form a continuous spectrum. We describe a Joint Maximum-Margin Classification and Clustering (JointMMCC) approach that jointly detects the pathologic population via semi-supervised classification, as well as disentangles heterogeneity of the pathological cohort by solving a clustering subproblem. We propose an efficient solution to the non-convex optimization problem associated with JointMMCC. We apply our proposed approach to an MRI study of aging, and identify coherent subpopulations (i.e., clusters) of cognitively less stable adults. PMID:22328179

  6. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system

    PubMed Central

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry® SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed. PMID:24851059

  7. 16 CFR Appendix C to Part 698 - Model Forms for Affiliate Marketing Opt-Out Notices

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Notices C Appendix C to Part 698 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT MODEL FORMS AND DISCLOSURES Pt. 698, App. C Appendix C to Part 698—Model Forms for Affiliate... of opt-outs by joint consumers to comply with § 680.23(a)(2) of part 680. C-1 Model Form for Initial...

  8. 16 CFR Appendix C to Part 698 - Model Forms for Affiliate Marketing Opt-Out Notices

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Notices C Appendix C to Part 698 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT MODEL FORMS AND DISCLOSURES Pt. 698, App. C Appendix C to Part 698—Model Forms for Affiliate... of opt-outs by joint consumers to comply with § 680.23(a)(2) of part 680. C-1 Model Form for Initial...

  9. 16 CFR Appendix C to Part 698 - Model Forms for Affiliate Marketing Opt-Out Notices

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Notices C Appendix C to Part 698 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT MODEL FORMS AND DISCLOSURES Pt. 698, App. C Appendix C to Part 698—Model Forms for Affiliate... of opt-outs by joint consumers to comply with § 680.23(a)(2) of part 680. C-1 Model Form for Initial...

  10. HMA Longitudinal Joint Evaluation and Construction

    DOT National Transportation Integrated Search

    2011-02-01

    Longitudinal joint quality is essential to the successful performance of asphalt pavements. A number of states have begun to implement longitudinal joint specifications, and most are based on determinations of density. However, distress at the joint ...

  11. Radiographic inspection of porosity in Ti-6Al-4V laser-welded joints.

    PubMed

    Nuñez-Pantoja, Juliana Maria Costa; Takahashi, Jessica Mie Ferreira Koyama; Nóbilo, Mauro Antônio de Arruda; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz

    2011-01-01

    Widely used in dentistry, Ti-6Al-4V alloy is difficult to cast and solder, as it frequently exhibits pores inside the structure. This study was conducted to evaluate the effect of joint openings and diameters of laser-welded joints executed in Ti-6Al-4V structures on the presence of pores as checked by radiographic procedures. Sixty dumbbell rods with central diameters of 1.5, 2.0 and 3.5 mm were created from Ti-6Al-4V-wrought bars. Specimens were sectioned and welded using two joint openings (0.0 and 0.6 mm). The combination of variables created six groups (n = 10). Laser welding was executed using 360V/8ms (1.5 and 2.0 mm) and 380V/9ms (3.5 mm), with the focus and frequency set to zero. The joints were finished, polished and submitted to radiographic examination. The radiographs were visually examined for the presence of pores in the joints, qualitatively. The percentage of radiographic presence of pores was calculated without counting pores per joint. Data were analyzed using a chi-square test (α = 0.05). For the 1.5-mm specimens, the incidence of pore presence was significantly higher (p = 0.0001) when using 0.6-mm joint openings (40%) compared to 0.0-mm openings (0%). For the 2.0-mm specimens, there was no significant difference between groups (p = 0.2008). However, for the 3.5-mm specimens, the incidence of pore presence was lower (p = 0.0061) for 0.6-mm openings (50%) compared to 0.0-mm openings (70%). Therefore, laser welding of Ti-6Al-4V structures with thin diameters provides the best condition for the juxtaposition of the parts.

  12. Intra-articular calcaneal fractures: effect of open reduction and internal fixation on the contact characteristics of the subtalar joint.

    PubMed

    Mulcahy, D M; McCormack, D M; Stephens, M M

    1998-12-01

    Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.

  13. The volume of the human knee joint.

    PubMed

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  14. Method of forming a joint

    DOEpatents

    Butt, Darryl Paul; Cutler, Raymond Ashton; Rynders, Steven Walton; Carolan, Michael Francis

    2006-08-22

    A method of joining at least two sintered bodies to form a composite structure, including providing a first multicomponent metallic oxide having a perovskitic or fluorite crystal structure; providing a second sintered body including a second multicomponent metallic oxide having a crystal structure of the same type as the first; and providing at an interface a joint material containing at least one metal oxide containing at least one metal identically contained in at least one of the first and second multicomponent metallic oxides. The joint material is free of cations of Si, Ge, Sn, Pb, P and Te and has a melting point below the sintering temperatures of both sintered bodies. The joint material is heated to a temperature above the melting point of the metal oxide(s) and below the sintering temperatures of the sintered bodies to form the joint. Structures containing such joints are also disclosed.

  15. RSRM Nozzle-to-Case Joint J-leg Development

    NASA Technical Reports Server (NTRS)

    Albrechtsen, Kevin U.; Eddy, Norman F.; Ewing, Mark E.; McGuire, John R.

    2003-01-01

    Since the beginning of the Space Shuttle Reusable Solid Rocket Motor (RSRM) program, nozzle-to-case joint polysulfide adhesive gas paths have occurred on several flight motors. These gas paths have allowed hot motor gases to reach the wiper O-ring. Even though these motors continue to fly safely with this condition, a desire was to reduce such occurrences. The RSRM currently uses a J-leg joint configuration on case field joints and igniter inner and outer joints. The J-leg joint configuration has been successfully demonstrated on numerous RSRM flight and static test motors, eliminating hot gas intrusion to the critical O-ring seals on these joints. Using the proven technology demonstrated on the case field joints and igniter joints, a nozzle-to-case joint J-leg design was developed for implementation on RSRM flight motors. This configuration provides an interference fit with nozzle fixed housing phenolics at assembly, with a series of pressurization gaps incorporated outboard of the joint mating surface to aid in joint pressurization and to eliminate any circumferential flow in this region. The joint insulation is bonded to the nozzle phenolics using the same pressure sensitive adhesive used in the case field joints and igniter joints. An enhancement to the nozzle-to-case joint J-leg configuration is the implementation of a carbon rope thermal barrier. The thermal barrier is located downstream of the joint bondline and is positioned within the joint in a manner where any hot gas intrusion into the joint passes through the thermal barrier, reducing gas temperatures to a level that would not affect O-rings downstream of the thermal barrier. This paper discusses the processes used in reaching a final nozzle-to-case joint J-leg design, provides structural and thermal results in support of the design, and identifies fabrication techniques and demonstrations used in arriving at the final configuration.

  16. Certificated Master Contract Agreement for 1987-90, Shasta-Tehama-Trinity Joint Community College District.

    ERIC Educational Resources Information Center

    Shasta-Tehama-Trinity Joint Community Coll. District, Redding, CA.

    This collective bargaining agreement between the Shasta-Tehama-Trinity Joint Community College District and the Shasta College Faculty Association establishes conditions of employment for all full- and part-time regular or contracted certificated employees of the district. The articles of the agreement set forth provisions related to: (1)…

  17. Minority Business Participation in Public/Private Partnerships: A Manual on Joint Development. Final Report.

    ERIC Educational Resources Information Center

    Beltran, Celestino M.; And Others

    The Urban Mass Transportation Association promotes Commercial real estate development projects in and adjacent to transit facilities as a means of generating additional revenues to defray part of local transit agency operating cost. Transit-related real estate development, or joint development, provides unique financial benefits for investors and…

  18. Prosthetic Joint Infections

    PubMed Central

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  19. Audio-based bolt-loosening detection technique of bolt joint

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Zhao, Xuefeng; Su, Wensheng; Xue, Zhigang

    2018-03-01

    Bolt joint, as the commonest coupling structure, is widely used in electro-mechanical system. However, it is the weakest part of the whole system. The increase of preload tension force can raise the reliability and strength of the bolt joint. Therefore, the pretension force is one of the most important factors to ensure the stability of bolt joint. According to the way of generating pretension force, the pretension force can be monitored by bolt torque, degrees and elongation. The existing bolt-loosening monitoring methods all require expensive equipment, which greatly restricts the practicality of the bolt-loosening monitoring. In this paper, a new method of bolt-loosening detection technique based on audio is proposed. The sound that bolt is hit by a hammer is recorded on the Smartphone, and the collected audio signal is classified and identified by support vector machine algorithm. First, a verification test was designed and the results show that this new method can identify the damage of bolt looseness accurately. Second, a variety of bolt-loosening was identified. The results indicate that this method has a high accuracy in multiclass classification of the bolt looseness. This bolt-loosening detection technique based on audio not only can reduce the requirements of technical and professional experience, but also make bolt-loosening monitoring simpler and easier.

  20. Common Bolted Joint Analysis Tool

    NASA Technical Reports Server (NTRS)

    Imtiaz, Kauser

    2011-01-01

    Common Bolted Joint Analysis Tool (comBAT) is an Excel/VB-based bolted joint analysis/optimization program that lays out a systematic foundation for an inexperienced or seasoned analyst to determine fastener size, material, and assembly torque for a given design. Analysts are able to perform numerous what-if scenarios within minutes to arrive at an optimal solution. The program evaluates input design parameters, performs joint assembly checks, and steps through numerous calculations to arrive at several key margins of safety for each member in a joint. It also checks for joint gapping, provides fatigue calculations, and generates joint diagrams for a visual reference. Optimum fastener size and material, as well as correct torque, can then be provided. Analysis methodology, equations, and guidelines are provided throughout the solution sequence so that this program does not become a "black box:" for the analyst. There are built-in databases that reduce the legwork required by the analyst. Each step is clearly identified and results are provided in number format, as well as color-coded spelled-out words to draw user attention. The three key features of the software are robust technical content, innovative and user friendly I/O, and a large database. The program addresses every aspect of bolted joint analysis and proves to be an instructional tool at the same time. It saves analysis time, has intelligent messaging features, and catches operator errors in real time.

  1. Adhesive-bonded scarf and stepped-lap joints

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1973-01-01

    Continuum mechanics solutions are derived for the static load-carrying capacity of scarf and stepped-lap adhesive-bonded joints. The analyses account for adhesive plasticity and adherend stiffness imbalance and thermal mismatch. The scarf joint solutions include a simple algebraic formula which serves as a close lower bound, within a small fraction of a per cent of the true answer for most practical geometries and materials. Digital computer programs were developed and, for the stepped-lap joints, the critical adherend and adhesive stresses are computed for each step. The scarf joint solutions exhibit grossly different behavior from that for double-lap joints for long overlaps inasmuch as that the potential bond shear strength continues to increase with indefinitely long overlaps on the scarf joints. The stepped-lap joint solutions exhibit some characteristics of both the scarf and double-lap joints. The stepped-lap computer program handles arbitrary (different) step lengths and thickness and the solutions obtained have clarified potentially weak design details and the remedies. The program has been used effectively to optimize the joint proportions.

  2. Exercises focusing on rotator cuff and scapular muscles do not improve shoulder joint position sense in healthy subjects.

    PubMed

    Lin, Yin-Liang; Karduna, Andrew

    2016-10-01

    Proprioception is essential for shoulder neuromuscular control and shoulder stability. Exercise of the rotator cuff and scapulothoracic muscles is an important part of shoulder rehabilitation. The purpose of this study was to investigate the effect of rotator cuff and scapulothoracic muscle exercises on shoulder joint position sense. Thirty-six healthy subjects were recruited and randomly assigned into either a control or training group. The subjects in the training group received closed-chain and open-chain exercises focusing on rotator cuff and scapulothoracic muscles for four weeks. Shoulder joint position sense errors in elevation, including the humerothoracic, glenohumeral and scapulothoracic joints, was measured. After four weeks of exercise training, strength increased overall in the training group, which demonstrated the effect of exercise on the muscular system. However, the changes in shoulder joint position sense errors in any individual joint of the subjects in the training group were not different from those of the control subjects. Therefore, exercises specifically targeting individual muscles with low intensity may not be sufficient to improve shoulder joint position sense in healthy subjects. Future work is needed to further investigate which types of exercise are more effective in improving joint position sense, and the mechanisms associated with those changes. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Exercises focusing on rotator cuff and scapular muscles do not improve shoulder joint position sense in healthy subjects

    PubMed Central

    Lin, Yin-Liang; Karduna, Andrew

    2016-01-01

    Proprioception is essential for shoulder neuromuscular control and shoulder stability. Exercise of the rotator cuff and scapulothoracic muscles is an important part of shoulder rehabilitation. The purpose of this study was to investigate the effect of rotator cuff and scapulothoracic muscle exercises on shoulder joint position sense. Thirty-six healthy subjects were recruited and randomly assigned into either a control or training group. The subjects in the training group received closed-chain and open-chain exercises focusing on rotator cuff and scapulothoracic muscles for four weeks. Shoulder joint position sense errors in elevation, including the humerothoracic, glenohumeral and scapulothoracic joints, was measured. After four weeks of exercise training, strength increased overall in the training group, which demonstrated the effect of exercise on the muscular system. However, the changes in shoulder joint position sense errors in any individual joint of the subjects in the training group were not different from those of the control subjects. Therefore, exercises specifically targeting individual muscles with low intensity may not be sufficient to improve shoulder joint position sense in healthy subjects. Future work is needed to further investigate which types of exercise are more effective in improving joint position sense, and the mechanisms associated with those changes. PMID:27475714

  4. Relationship of HS CRP and Sacroiliac Joint Inflammation in Undifferentiated Spondyloarthritis.

    PubMed

    Liu, Te-Jung; Chang, Cheng-Chiang; Chen, Liang-Cheng; Chu, Heng-Yi; Hsu, Chun-Sheng; Chang, Shin-Tsu

    2018-01-01

    Elevation of serum high sensitivity C-reactive protein (hs-CRP) level has been demonstrated as a risk factor for varying diseases, as well as a biomarker for predicting recovery after operation of lumber disc herniation. Our objective was to investigate the relationship between serum hs-CRP and sacroiliac (SI) joint inflammation in patients with undifferentiated spondyloarthritis (uSpA). In this retrospective study, we enrolled patients with uSpA who underwent hs-CRP testing between January 2007 and September 2013. Serum hs-CRP was analyzed at our central laboratory. All enrolled patients underwent skeletal scintigraphic scan with quantitative sacroiliac measurement. A total of 29 patients were enrolled with mean age 32.27 years and female:male ratio of 6:23. Pearson's correlation coefficient showed a significant difference between hs-CRP in serum and SI/S ratio in uSpA, particularly the middle part of the sacroiliac joint, either right side or left side. The significantly high concentration of serum hs-CRP might indicate a systemic inflammatory response to flare-up of the SI joint and might be an indicator of SI inflammation in uSpA.

  5. Relationship of HS CRP and Sacroiliac Joint Inflammation in Undifferentiated Spondyloarthritis

    PubMed Central

    Liu, Te-Jung; Chang, Cheng-Chiang; Chen, Liang-Cheng; Chu, Heng-Yi; Hsu, Chun-Sheng; Chang, Shin-Tsu

    2018-01-01

    Abstract Objective Elevation of serum high sensitivity C-reactive protein (hs-CRP) level has been demonstrated as a risk factor for varying diseases, as well as a biomarker for predicting recovery after operation of lumber disc herniation. Our objective was to investigate the relationship between serum hs-CRP and sacroiliac (SI) joint inflammation in patients with undifferentiated spondyloarthritis (uSpA). Methods In this retrospective study, we enrolled patients with uSpA who underwent hs-CRP testing between January 2007 and September 2013. Serum hs-CRP was analyzed at our central laboratory. All enrolled patients underwent skeletal scintigraphic scan with quantitative sacroiliac measurement. Results A total of 29 patients were enrolled with mean age 32.27 years and female:male ratio of 6:23. Pearson’s correlation coefficient showed a significant difference between hs-CRP in serum and SI/S ratio in uSpA, particularly the middle part of the sacroiliac joint, either right side or left side. The significantly high concentration of serum hs-CRP might indicate a systemic inflammatory response to flare-up of the SI joint and might be an indicator of SI inflammation in uSpA. PMID:29785410

  6. 76 FR 28040 - Medicare and Medicaid Programs; Application by the Joint Commission for Continued Deeming...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ... furnish information for use in enforcement activities; monitoring procedures for provider entities found... agreements are at 42 CFR part 489 and those pertaining to activities relating to the survey and certification... for monitoring CAHs found out of compliance with the Joint Commission's program requirements. These...

  7. Dynamic Analyses Including Joints Of Truss Structures

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith

    1991-01-01

    Method for mathematically modeling joints to assess influences of joints on dynamic response of truss structures developed in study. Only structures with low-frequency oscillations considered; only Coulomb friction and viscous damping included in analysis. Focus of effort to obtain finite-element mathematical models of joints exhibiting load-vs.-deflection behavior similar to measured load-vs.-deflection behavior of real joints. Experiments performed to determine stiffness and damping nonlinearities typical of joint hardware. Algorithm for computing coefficients of analytical joint models based on test data developed to enable study of linear and nonlinear effects of joints on global structural response. Besides intended application to large space structures, applications in nonaerospace community include ground-based antennas and earthquake-resistant steel-framed buildings.

  8. Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations.

    PubMed

    Koelewijn, Anne D; van den Bogert, Antonie J

    2016-09-01

    Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. [Interpretation of ultrasound findings in otorhinolaryngology. Salivary glands, paraganglioma, angioma, esophagus, hypopharynx, extra cranial vessels and temporomandibular joint].

    PubMed

    Bozzato, A

    2015-06-01

    The second part of this continuing medical education article focuses on sonographic assessment of the salivary glands, cervical paraganglioma, angioma, esophagus, extra cranial blood vessels and the temporomandibular joint. The currently available minimally invasive therapeutic options (e. g. sialendoscopy, lithotripsy, therapeutic duct lavage and extracapsular dissection) for salivary gland disease presuppose a precise imaging modality. Modern ultrasound is able to meet this challenge, making additional imaging a rare necessity. Regions of the neck with a difficult topography (esophagus and hypopharynx) can often be successfully portrayed sonographically. Furthermore, ultrasound enables functional evaluation of swallowing in the cervical parts of the esophagus in dysphagia patients. In addition to the branchial cleft anomalies and lymph nodes discussed in part 1, paraganglioma, angiomatosis and neurogenic tumors are important differential diagnoses of solid lesions of the neck. Finally, venous and arterial alterations of the extracranial vessels of the neck relevant to clinical routine are depicted, as are pathological conditions of the temporomandibular joint relevant to the otorhinolaryngologist.

  10. 77 FR 39560 - International Joint Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ... DEPARTMENT OF STATE [Public Notice 7945] International Joint Commission International Joint Commission Invites Public Comment on Upper Great Lakes Report The International Joint Commission (IJC) announced today that it is inviting public comment on the final report of its International Upper Great...

  11. Joint torques in a freely walking insect reveal distinct functions of leg joints in propulsion and posture control

    PubMed Central

    2016-01-01

    Determining the mechanical output of limb joints is critical for understanding the control of complex motor behaviours such as walking. In the case of insect walking, the neural infrastructure for single-joint control is well described. However, a detailed description of the motor output in form of time-varying joint torques is lacking. Here, we determine joint torques in the stick insect to identify leg joint function in the control of body height and propulsion. Torques were determined by measuring whole-body kinematics and ground reaction forces in freely walking animals. We demonstrate that despite strong differences in morphology and posture, stick insects show a functional division of joints similar to other insect model systems. Propulsion was generated by strong depression torques about the coxa–trochanter joint, not by retraction or flexion/extension torques. Torques about the respective thorax–coxa and femur–tibia joints were often directed opposite to fore–aft forces and joint movements. This suggests a posture-dependent mechanism that counteracts collapse of the leg under body load and directs the resultant force vector such that strong depression torques can control both body height and propulsion. Our findings parallel propulsive mechanisms described in other walking, jumping and flying insects, and challenge current control models of insect walking. PMID:26791608

  12. Student perspectives on the development and evaluation of a joint international education to promote employability in Europe.

    PubMed

    Craig, Claire; Piškur, Barbara

    2012-01-01

    This article presents a student evaluation of a joint international education developed as part of a European project which sought to equip health care practitioners with the skills to support employability of individuals furthest removed from the labour market, disadvantaged on account of age, gender, migration or ethnicity. Thirty eight students out of the forty one students that participated in the pilot of four modules (NL, UK, SE, DE) returned completed digital questionnaires (92.6% response rate). The study is descriptive by nature. A questionnaire was used to collect the data from students. Additionally students attending the module in the UK also took part in a series of qualitative interviews which sought to explore their experiences in more detail. These were recorded, transcribed and analyzed. Students reported that joint education facilitates competence development. The competencies they identified (Information Communications Technology) were recognised as being key to enhancing employability of disadvantaged groups. The joint international education exemplified by EEE4all offers one model of how to build a responsive international curriculum to ensure that the workforce of the future is well placed to meet the needs of this changing world.

  13. Early Osteoarthritis of the Trapeziometacarpal Joint Is Not Associated With Joint Instability during Typical Isometric Loading

    PubMed Central

    Halilaj, Eni; Moore, Douglas C.; Patel, Tarpit K.; Ladd, Amy L.; Weiss, Arnold-Peter C.; Crisco, Joseph J.

    2015-01-01

    The saddle-shaped trapeziometacarpal (TMC) joint contributes importantly to the function of the human thumb. A balance between mobility and stability is essential in this joint, which experiences high loads and is prone to osteoarthritis (OA). Since instability is considered a risk factor for TMC OA, we assessed TMC joint instability during the execution of three isometric functional tasks (key pinch, jar grasp, and jar twist) in 76 patients with early TMC OA and 44 asymptomatic controls. Computed tomography images were acquired while subjects held their hands relaxed and while they applied 80% of their maximum effort for each task. Six degree-of-freedom rigid body kinematics of the metacarpal with respect to the trapezium from the unloaded to the loaded task positions were computed in terms of a TMC joint coordinate system. Joint instability was expressed as a function of the metacarpal translation and the applied force. We found that the TMC joint was more unstable during a key pinch task than during a jar grasp or a jar twist task. Sex, age, and early OA did not have an effect on TMC joint instability, suggesting that instability during these three tasks is not a predisposing factor in TMC OA. PMID:25941135

  14. Outline and Evaluation of a Joint European and Canadian Virtual Mobility: e-Learning Project

    ERIC Educational Resources Information Center

    Hilliard, Alan

    2006-01-01

    The "virtual mobility" project was created as part of a joint Canadian and European Commission funded project to explore cross-cultural clinical curricular developments in the radiation sciences. The aim of the project was to facilitate student learning of the cross-cultural differences in the delivery of healthcare within the…

  15. Improved Automatically Locking/Unlocking Orthotic Knee Joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1995-01-01

    Proposed orthotic knee joint improved version of one described in "Automatically Locking/Unlocking Orthotic Knee Joint" (MFS-28633). Locks automatically upon initial application of radial force (wearer's weight) and unlocks automatically, but only when all loads (radial force and bending) relieved. Joints lock whenever wearer applies weight to knee at any joint angle between full extension and 45 degree bend. Both devices offer increased safety and convenience relative to conventional orthotic knee joints.

  16. Real-Time Visualization of Joint Cavitation

    PubMed Central

    Rowe, Lindsay

    2015-01-01

    Cracking sounds emitted from human synovial joints have been attributed historically to the sudden collapse of a cavitation bubble formed as articular surfaces are separated. Unfortunately, bubble collapse as the source of joint cracking is inconsistent with many physical phenomena that define the joint cracking phenomenon. Here we present direct evidence from real-time magnetic resonance imaging that the mechanism of joint cracking is related to cavity formation rather than bubble collapse. In this study, ten metacarpophalangeal joints were studied by inserting the finger of interest into a flexible tube tightened around a length of cable used to provide long-axis traction. Before and after traction, static 3D T1-weighted magnetic resonance images were acquired. During traction, rapid cine magnetic resonance images were obtained from the joint midline at a rate of 3.2 frames per second until the cracking event occurred. As traction forces increased, real-time cine magnetic resonance imaging demonstrated rapid cavity inception at the time of joint separation and sound production after which the resulting cavity remained visible. Our results offer direct experimental evidence that joint cracking is associated with cavity inception rather than collapse of a pre-existing bubble. These observations are consistent with tribonucleation, a known process where opposing surfaces resist separation until a critical point where they then separate rapidly creating sustained gas cavities. Observed previously in vitro, this is the first in-vivo macroscopic demonstration of tribonucleation and as such, provides a new theoretical framework to investigate health outcomes associated with joint cracking. PMID:25875374

  17. Joint Disorders - Multiple Languages

    MedlinePlus

    ... a new window. Arabic (العربية) Expand Section Home Care After Total Joint Replacement - العربية (Arabic) Bilingual PDF Health Information Translations Bosnian (bosanski) Expand Section Home Care After Total Joint Replacement - bosanski (Bosnian) Bilingual PDF Health Information ...

  18. 15 CFR 296.8 - Joint venture agreement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS TECHNOLOGY INNOVATION PROGRAM General § 296.8 Joint venture agreement. NIST shall not issue a TIP award to a joint venture and... joint venture agreement has been executed by all of the joint venture members and approved by NIST. ...

  19. 15 CFR 296.8 - Joint venture agreement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS TECHNOLOGY INNOVATION PROGRAM General § 296.8 Joint venture agreement. NIST shall not issue a TIP award to a joint venture and... joint venture agreement has been executed by all of the joint venture members and approved by NIST. ...

  20. 15 CFR 296.8 - Joint venture agreement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS TECHNOLOGY INNOVATION PROGRAM General § 296.8 Joint venture agreement. NIST shall not issue a TIP award to a joint venture and... joint venture agreement has been executed by all of the joint venture members and approved by NIST. ...

  1. 15 CFR 296.8 - Joint venture agreement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS TECHNOLOGY INNOVATION PROGRAM General § 296.8 Joint venture agreement. NIST shall not issue a TIP award to a joint venture and... joint venture agreement has been executed by all of the joint venture members and approved by NIST. ...

  2. 15 CFR 296.8 - Joint venture agreement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS TECHNOLOGY INNOVATION PROGRAM General § 296.8 Joint venture agreement. NIST shall not issue a TIP award to a joint venture and... joint venture agreement has been executed by all of the joint venture members and approved by NIST. ...

  3. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    PubMed

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  4. Structural analysis of Aircraft fuselage splice joint

    NASA Astrophysics Data System (ADS)

    Udaya Prakash, R.; Kumar, G. Raj; Vijayanandh, R.; Senthil Kumar, M.; Ramganesh, T.

    2016-09-01

    In Aviation sector, composite materials and its application to each component are one of the prime factors of consideration due to the high strength to weight ratio, design flexibility and non-corrosive so that the composite materials are widely used in the low weight constructions and also it can be treated as a suitable alternative to metals. The objective of this paper is to estimate and compare the suitability of a composite skin joint in an aircraft fuselage with different joints by simulating the displacement, normal stress, vonmises stress and shear stress with the help of numerical solution methods. The reference Z-stringer component of this paper is modeled by CATIA and numerical simulation is carried out by ANSYS has been used for splice joint presents in the aircraft fuselage with three combinations of joints such as riveted joint, bonded joint and hybrid joint. Nowadays the stringers are using to avoid buckling of fuselage skin, it has joined together by rivets and they are connected end to end by splice joint. Design and static analysis of three-dimensional models of joints such as bonded, riveted and hybrid are carried out and results are compared.

  5. Dorsoradial capsulodesis for trapeziometacarpal joint instability.

    PubMed

    Rayan, Ghazi; Do, Viet

    2013-02-01

    We describe an alternative method for treating chronic trapeziometacarpal (TM) joint instability after acute injury or chronic repetitive use of the thumb by performing a dorsoradial capsulodesis procedure. The procedure is done by imbricating the redundant TM joint dorsoradial ligament and capsule after reducing the joint by pronating the thumb. The dorsoradial capsulodesis is a reasonable reconstructive option for chronic TM joint instability and subluxation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. Flat H Frangible Joint Evolution

    NASA Technical Reports Server (NTRS)

    Diegelman, Thomas E.; Hinkel, Todd J.; Benjamin, Andrew; Rochon, Brian V.; Brown, Christopher W.

    2016-01-01

    three-dimensional envelope as current designs as well as meet structural loads requirements. There is increased mass associated with the redundant design, and the goal is to minimize the weight impact as much as possible. These requirements presented significant challenges, both technically and financially; these challenges will be explored in this paper. Perhaps greater than the technical issues confronted during this design process, were the financial considerations. These were a significant part of the story of this design and development plan. Insufficient financial and labor resources were formidable barriers to completing this project. Nevertheless, JSC personnel successfully conducted several test series at JSC with very useful results. The many lessons learned drove design improvements, performance efficiency, and increased functional reliability. This paper examines the significant technical and financial challenges that these requirements posed to the project team. It discusses the evolution of the SFT frangible joint design, including optimization, testing, and successful partnering of the Johnson Space Center (JSC) engineering and JSC safety organizations, to enhance the flight safety margin for America's next generation of human-rated space vehicles.

  7. 17 CFR Appendix A to Part 190 - Bankruptcy Forms

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... foreign futures or foreign options secured amount, as defined in § 1.3 of this chapter. a. The trustee... undersigned futures commission merchant]; 7. [The account is held by the undersigned as part owner of a joint... member of the debtor which is an officer, director or manager]; 6. [An employee of such individual...

  8. 17 CFR Appendix A to Part 190 - Bankruptcy Forms

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... foreign futures or foreign options secured amount, as defined in § 1.3 of this chapter. a. The trustee... undersigned futures commission merchant]; 7. [The account is held by the undersigned as part owner of a joint... member of the debtor which is an officer, director or manager]; 6. [An employee of such individual...

  9. Numerical Investigation of T-joints with 3D Four Directional Braided Composite Fillers Under Tensile Loading

    NASA Astrophysics Data System (ADS)

    Li, Xiao-kang; Liu, Zhen-guo; Hu, Long; Wang, Yi-bo; Lei, Bing; Huang, Xiang

    2017-02-01

    Numerical studied on T-joints with three-dimensional four directional (3D4D) braided composite fillers was presented in this article. Compared with conventional unidirectional prepreg fillers, the 3D braided composite fillers have excellent ability to prevent crack from penetrating trigone fillers, which constantly occurred in the conventional fillers. Meanwhile, the 3D braided composite fillers had higher fiber volume fraction and eliminated the fiber folding problem in unidirectional prepreg fillers. The braiding technology and mechanical performance of 3D4D braided fillers were studied. The numerical model of carbon fiber T-joints with 3D4D braided composite fillers was built by finite element analysis software. The damage formation, extension and failing process of T-joints with 3D4D braided fillers under tensile load were investigated. Further investigation was extended to the effect of 3D4D braided fillers with different braiding angles on mechanical behavior of the T-joints. The study results revealed that the filling area was the weakest part of the T-joints where the damage first appeared and the crack then rapidly spread to the glue film around the filling area and the interface between over-laminate and soleplate. The 3D4D braided fillers were undamaged and the braiding angle change induced a little effect on the bearing capacity of T-joints.

  10. [Human joint capsule in osteoarthrosis (morpholocical changes) (author's transl)].

    PubMed

    Dettmer, N; Barz, B

    1977-07-29

    Morphological investigations of the joint capsules in osteoarthrotic-changed joints have given rise to doubts about the present theory of the causal aetiology of the osteoarthrosis. In every inspected and demonstrated illustration beside the partly normal capsules segments could be found every transition between mild regressive alterations and most massive proliferative changes of the conective tissue and the lining cell layer. It was extraordinary, that the strongly dilated vessels were filled with red blood cells. In another part of the same case was found a massive stricture caused by concentrically deposited substances, which were impregnated with collagenous fibers. Regeneration of the vessels frequently happened adjacent totally obstructed ones. Round-cell infiltrations, granulocytes or other indications of an inflammatory synovitis are found only in a few cases. The intracartilaginous enzymatic reactions, which have been much talked of and which were explained as characteristic of the osteoarthrosis cannot be the cause of the degradation of the cartilage, particularly, because of the normal cell count which is to be found in the synovial fluid. We can answer this problem, if we can prove that the substrates of the chondral metabolism themselves exert a direct or indirect influence on the interstitial connective tissue with induction of the powerful proliferation of the same tissue. The changes in the transit zone would be secondary and their effect on the lining cell layer would increase the progression of the arthrotic events.

  11. CLINICAL AND TREATMENT FEATURES OF OPEN INFECTED FRACTURES IN THE KNEE JOINT REGION IN CONJUNCTION WITH RADIATION SICKNESS (EXPERIMENTAL STUDY)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakharov, B.V.

    1963-08-01

    Clinical aspects and the course of treatment of open infected fractures in the knee joint region against a background of moderate and severe radiation sickness are discussed. The experiment involved 35 healthy dogs of both sexes. In all, three experiments were involved: on open infected fractures in the knee joint region in conjunction with radiation sickness; open infected fractures in the knee joint region without radiation sickness; radiation sickness without trauma. Infected open injury to the knee joint against a radiation sickness background is a severe affection. The use of delayed surgical and drug treatment (antibiotics, vitamins, antihistamine preparations) affordedmore » survival of at least one-half of the animals. Oral use of phenoxymethyl-penicillin in large doses established in the blood and synovial fluid of the damaged knee joint a therapeutic concentration of antibiotic of long duration (not less than a day). In radiation damage to knee joint accompanied by fracture of the bone fragment, the best method of surgical treatment is osteosynthesis using metal parts. In open infection of a damaged knee joint against a radiation sickness background, even with proper treatment a tendency toward formation of deforming arthrosis was observed. (OTS)« less

  12. Imaging of juvenile idiopathic arthritis. Part I: Clinical classifications and radiographs

    PubMed Central

    Matuszewska, Genowefa; Gietka, Piotr; Płaza, Mateusz; Walentowska-Janowicz, Marta

    2016-01-01

    Juvenile idiopathic arthritis is the most common autoimmune systemic disease of the connective tissue affecting individuals at the developmental age. Radiography is the primary modality employed in the diagnostic imaging in order to identify changes typical of this disease entity and rule out other bone-related pathologies, such as neoplasms, posttraumatic changes, developmental defects and other forms of arthritis. The standard procedure involves the performance of comparative joint radiographs in two planes. Radiographic changes in juvenile idiopathic arthritis are detected in later stages of the disease. Bone structures are assessed in the first place. Radiographs can also indirectly indicate the presence of soft tissue inflammation (i.e. in joint cavities, sheaths and bursae) based on swelling and increased density of the soft tissue as well as dislocation of fat folds. Signs of articular cartilage defects are also seen in radiographs indirectly – based on joint space width changes. The first part of the publication presents the classification of juvenile idiopathic arthritis and discusses its radiographic images. The authors list the affected joints as well as explain the spectrum and specificity of radiographic signs resulting from inflammatory changes overlapping with those caused by the maturation of the skeletal system. Moreover, certain dilemmas associated with the monitoring of the disease are reviewed. The second part of the publication will explain issues associated with ultrasonography and magnetic resonance imaging, which are more and more commonly applied in juvenile idiopathic arthritis for early detection of pathological features as well as the disease complications. PMID:27679726

  13. Cold forging and chemical heat treatment of the casing of the internal joint for VAZ cars

    NASA Astrophysics Data System (ADS)

    Arzamastsev, V. A.; Sardaev, N. L.; Kochergin, A. S.

    1996-11-01

    The technological process of cold forging applied for the first time in the production of the casing of the internal joint with races is described. The process operations of cold forging and the annealing and carburizing regimes for this part me described.

  14. Look before You Leap: Underestimating Chinese Student History, Chinese University Setting and Chinese University Steering in Sino-British HE Joint Ventures?

    ERIC Educational Resources Information Center

    Dow, Ewan G.

    2010-01-01

    This article makes the case--in three parts--that many Anglo-Chinese university collaborations (joint ventures) to date have seriously underestimated Chinese (student) history, the Chinese university setting and Chinese national governmental steering as part of the process of "glocalisation". Recent turbulence in this particular HE…

  15. Increased expression of damage-associated molecular patterns (DAMPs) in osteoarthritis of human knee joint compared to hip joint.

    PubMed

    Rosenberg, John H; Rai, Vikrant; Dilisio, Matthew F; Sekundiak, Todd D; Agrawal, Devendra K

    2017-12-01

    Osteoarthritis (OA) is a degenerative disease characterized by the destruction of cartilage. The greatest risk factors for the development of OA include age and obesity. Recent studies suggest the role of inflammation in the pathogenesis of OA. The two most common locations for OA to occur are in the knee and hip joints. The knee joint experiences more mechanical stress, cartilage degeneration, and inflammation than the hip joint. This could contribute to the increased incidence of OA in the knee joint. Damage-associated molecular patterns (DAMPs), including high-mobility group box-1, receptor for advanced glycation end products, and alarmins (S100A8 and S100A9), are released in the joint in response to stress-mediated chondrocyte and cartilage damage. This facilitates increased cartilage degradation and inflammation in the joint. Studies have documented the role of DAMPs in the pathogenesis of OA; however, the comparison of DAMPs and its influence on OA has not been discussed. In this study, we compared the DAMPs between OA knee and hip joints and found a significant difference in the levels of DAMPs expressed in the knee joint compared to the hip joint. The increased levels of DAMPs suggest a difference in the underlying pathogenesis of OA in the knee and the hip and highlights DAMPs as potential therapeutic targets for OA in the future.

  16. Transcription factor ERG and joint and articular cartilage formation during mouse limb and spine skeletogenesis.

    PubMed

    Iwamoto, Masahiro; Tamamura, Yoshihiro; Koyama, Eiki; Komori, Toshihisa; Takeshita, Nobuo; Williams, Julie A; Nakamura, Takashi; Enomoto-Iwamoto, Motomi; Pacifici, Maurizio

    2007-05-01

    Articular cartilage and synovial joints are critical for skeletal function, but the mechanisms regulating their development are largely unknown. In previous studies we found that the ets transcription factor ERG and its alternatively-spliced variant C-1-1 have roles in joint formation in chick. Here, we extended our studies to mouse. We found that ERG is also expressed in developing mouse limb joints. To test regulation of ERG expression, beads coated with the joint master regulator protein GDF-5 were implanted close to incipient joints in mouse limb explants; this led to rapid and strong ectopic ERG expression. We cloned and characterized several mammalian ERG variants and expressed a human C-1-1 counterpart (hERG3Delta81) throughout the cartilaginous skeleton of transgenic mice, using Col2a1 gene promoter/enhancer sequences. The skeletal phenotype was severe and neonatal lethal, and the transgenic mice were smaller than wild type littermates and their skeletons were largely cartilaginous. Limb long bone anlagen were entirely composed of chondrocytes actively expressing collagen IX and aggrecan as well as articular markers such as tenascin-C. Typical growth plates were absent and there was very low expression of maturation and hypertrophy markers, including Indian hedgehog, collagen X and MMP-13. The results suggest that ERG is part of molecular mechanisms leading chondrocytes into a permanent developmental path and become joint forming cells, and may do so by acting downstream of GDF-5.

  17. Three-part joint modeling methods for complex functional data mixed with zero-and-one-inflated proportions and zero-inflated continuous outcomes with skewness.

    PubMed

    Li, Haocheng; Staudenmayer, John; Wang, Tianying; Keadle, Sarah Kozey; Carroll, Raymond J

    2018-02-20

    We take a functional data approach to longitudinal studies with complex bivariate outcomes. This work is motivated by data from a physical activity study that measured 2 responses over time in 5-minute intervals. One response is the proportion of time active in each interval, a continuous proportions with excess zeros and ones. The other response, energy expenditure rate in the interval, is a continuous variable with excess zeros and skewness. This outcome is complex because there are 3 possible activity patterns in each interval (inactive, partially active, and completely active), and those patterns, which are observed, induce both nonrandom and random associations between the responses. More specifically, the inactive pattern requires a zero value in both the proportion for active behavior and the energy expenditure rate; a partially active pattern means that the proportion of activity is strictly between zero and one and that the energy expenditure rate is greater than zero and likely to be moderate, and the completely active pattern means that the proportion of activity is exactly one, and the energy expenditure rate is greater than zero and likely to be higher. To address these challenges, we propose a 3-part functional data joint modeling approach. The first part is a continuation-ratio model to reorder the ordinal valued 3 activity patterns. The second part models the proportions when they are in interval (0,1). The last component specifies the skewed continuous energy expenditure rate with Box-Cox transformations when they are greater than zero. In this 3-part model, the regression structures are specified as smooth curves measured at various time points with random effects that have a correlation structure. The smoothed random curves for each variable are summarized using a few important principal components, and the association of the 3 longitudinal components is modeled through the association of the principal component scores. The difficulties in

  18. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... replaced. (d) Each rail shall be bolted with at least two bolts at each joint. (e) Each joint bar shall be... in this subpart. (f) No rail shall have a bolt hole which is torch cut or burned. (g) No joint bar shall be reconfigured by torch cutting. ...

  19. Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint.

    PubMed

    McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A

    2012-08-30

    Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.

  20. Joint Newspaper Operating Agreements.

    ERIC Educational Resources Information Center

    Parsons, Marie

    The number of competing daily newspapers in American cities has dwindled until only about 50 cities boast two papers. Of the newspapers in those cities, 23 now maintain separate editorial operations but have joint printing, advertising, and circulation departments. The concept of joint operation is 50 years old, dating from the Depression years…

  1. Strength evaluation of socket joints

    NASA Technical Reports Server (NTRS)

    Rash, Larry C.

    1994-01-01

    This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.

  2. 37 CFR 1.45 - Joint inventors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... joint application under 35 U.S.C. 116. If multiple inventors are named in a provisional application... disclosed in the provisional application and the provisional application will be considered to be a joint... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Joint inventors. 1.45 Section...

  3. BIOMECHANICS AND PATHOMECHANICS OF THE PATELLOFEMORAL JOINT

    PubMed Central

    2016-01-01

    The patellofemoral joint is a joint that can be an area of concern for athletes of various sports and ages. The joint is somewhat complex with multiple contact points and numerous tissues that attach to the patella. Joint forces are variable and depend on the degree of knee flexion and whether the foot is in contact with the ground. The sports medicine specialist must have a good working knowledge of the anatomy and biomechanics of the patellofemoral joint in order to treat it effectively. PMID:27904787

  4. NASA-DoD Lead-Free Electronics Project. DRAFT Joint Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt

    2011-01-01

    . The longer the transition period, the greater the likelihood of Pb-free parts inadvertently being mixed with Pb parts and ending up on what are supposed to be Pb systems. As a result, OEMs, depots, and support contractors need to take action now to either abate the influx of Pb-free parts, or accept it and deal with the likely interim consequences of reduced reliability due to a wide variety of matters, such as Pb contamination, high temperature incompatibility, and tin whiskering. Allowance of Pb-free components produces one of the greatest risks to the reliability of a weapon system. This is due to new and poorly understood failure mechanisms, as well as unknown long-term reliability. If the decision is made to consciously allow Pb-free solder and component finishes into SnPb electronics, additional effort (and cost) will be required to make the significant number of changes to drawings and task order procedures. This project is a follow-on effort to the Joint Council on Aging Aircraft/Joint Group on Pollution Prevention (JCAA/JG-PP) Pb-free Solder Project which was the first group to test the reliability of Pb-free solder joints against the requirements of the aerospace and military community.

  5. Fault and joint geometry at Raft River Geothermal Area, Idaho

    NASA Astrophysics Data System (ADS)

    Guth, L. R.; Bruhn, R. L.; Beck, S. L.

    1981-07-01

    Raft River geothermal reservoir is formed by fractures in sedimentary strata of the Miocene and Pliocene salt lake formation. The fracturing is most intense at the base of the salt lake formation, along a decollement that dips eastward at less than 50 on top of metamorphosed precambrian and lower paleozoic rocks. Core taken from less than 200 m above the decollement contains two sets of normal faults. The major set of faults dips between 500 and 700. These faults occur as conjugate pairs that are bisected by vertical extension fractures. The second set of faults dips 100 to 200 and may parallel part of the basal decollement or reflect the presence of listric normal faults in the upper plate. Surface joints form two suborthogonal sets that dip vertically. East-northeast-striking joints are most frequent on the limbs of the Jim Sage anticline, a large fold that is associated with the geothermal field.

  6. Geared Electromechanical Rotary Joint

    NASA Technical Reports Server (NTRS)

    Vranish, John M.

    1994-01-01

    Geared rotary joint provides low-noise ac or dc electrical contact between electrical subsystems rotating relative to each other. Designed to overcome some disadvantages of older electromechanical interfaces, especially intermittency of sliding-contact and rolling-contact electromechanical joints. Hollow, springy planetary gears provide continuous, redundant, low-noise electrical contact between inner and outer gears.

  7. Space Shuttle Main Engine Joint Data List Applying Today's Desktop Technologies to Facilitate Engine Processing

    NASA Technical Reports Server (NTRS)

    Jacobs, Kenneth; Drobnick, John; Krell, Don; Neuhart, Terry; McCool, A. (Technical Monitor)

    2001-01-01

    Boeing-Rocketdyne's Space Shuttle Main Engine (SSME) is the world's first large reusable liquid rocket engine. The space shuttle propulsion system has three SSMEs, each weighing 7,400 lbs and providing 470,000 lbs of thrust at 100% rated power level. To ensure required safety and reliability levels are achieved with the reusable engines, each SSME is partially disassembled, inspected, reassembled, and retested at Kennedy Space Center between each flight. Maintenance processing must be performed very carefully to replace any suspect components, maintain proper engine configuration, and avoid introduction of contaminants that could affect performance and safety. The long service life, and number, complexity, and pedigree of SSME components makes logistics functions extremely critical. One SSME logistics challenge is documenting the assembly and disassembly of the complex joint configurations. This data (joint nomenclature, seal and fastener identification and orientation, assembly sequence, fastener torques, etc.) must be available to technicians and engineers during processing. Various assembly drawings and procedures contain this information, but in this format the required (practical) joint data can be hard to find, due to the continued use of archaic engineering drawings and microfilm for field site use. Additionally, the release system must traverse 2,500 miles between design center and field site, across three time zones, which adds communication challenges and time lags for critical engine configuration data. To aid in information accessibility, a Joint Data List (JDL) was developed that allows efficient access to practical joint data. The published JDL has been a very useful logistics product, providing illustrations and information on the latest SSME configuration. The JDL identifies over 3,350 unique parts across seven fluid systems, over 300 joints, times two distinct engine configurations. The JDL system was recently converted to a web-based, navigable

  8. Temporal gene expression profiling of the rat knee joint capsule during immobilization-induced joint contractures.

    PubMed

    Wong, Kayleigh; Sun, Fangui; Trudel, Guy; Sebastiani, Paola; Laneuville, Odette

    2015-05-26

    Contractures of the knee joint cause disability and handicap. Recovering range of motion is recognized by arthritic patients as their preference for improved health outcome secondary only to pain management. Clinical and experimental studies provide evidence that the posterior knee capsule prevents the knee from achieving full extension. This study was undertaken to investigate the dynamic changes of the joint capsule transcriptome during the progression of knee joint contractures induced by immobilization. We performed a microarray analysis of genes expressed in the posterior knee joint capsule following induction of a flexion contracture by rigidly immobilizing the rat knee joint over a time-course of 16 weeks. Fold changes of expression values were measured and co-expressed genes were identified by clustering based on time-series analysis. Genes associated with immobilization were further analyzed to reveal pathways and biological significance and validated by immunohistochemistry on sagittal sections of knee joints. Changes in expression with a minimum of 1.5 fold changes were dominated by a decrease in expression for 7732 probe sets occurring at week 8 while the expression of 2251 probe sets increased. Clusters of genes with similar profiles of expression included a total of 162 genes displaying at least a 2 fold change compared to week 1. Functional analysis revealed ontology categories corresponding to triglyceride metabolism, extracellular matrix and muscle contraction. The altered expression of selected genes involved in the triglyceride biosynthesis pathway; AGPAT-9, and of the genes P4HB and HSP47, both involved in collagen synthesis, was confirmed by immunohistochemistry. Gene expression in the knee joint capsule was sensitive to joint immobility and provided insights into molecular mechanisms relevant to the pathophysiology of knee flexion contractures. Capsule responses to immobilization was dynamic and characterized by modulation of at least three

  9. Conarticular congruence of the hominoid subtalar joint complex with implications for joint function in Plio-Pleistocene hominins.

    PubMed

    Prang, Thomas C

    2016-07-01

    The purpose of this study is to test the hypothesis that conarticular surfaces areas and curvatures are correlates of mobility at the hominoid talocalcaneal and talonavicular joints. Articular surface areas and curvatures of the talonavicular, anterior talocalcaneal, and posterior talocalcaneal joints were quantified using a total of 425 three-dimensional surface models of extant hominoid and fossil hominin tali, calcanei, and naviculars. Quadric surface fitting was used to calculate curvatures, pairwise comparisons were used to evaluate statistical differences between taxa, and regression was used to test for the effects of allometry. Pairwise comparisons show that the distributions of values for joint curvature indices follow the predicted arboreal-terrestrial morphocline in hominoid primates with no effect of body mass (PGLS p > 0.05). OH 8 (Homo habilis) and LB 1 (Homo floresiensis) can be accommodated within the range of human variation for the talonavicular joint, whereas MH2 (Australopithecus sediba) falls within the ranges of variation for Pan troglodytes and Gorilla gorilla in measures of posterior talocalcaneal joint congruity. Joint curvature indices are better discriminators than joint surface area indices, which may reflect a greater contribution of rotation, rather than translation, to joint movement in plantigrade taxa due to discrepancies in conarticular congruence and the "convex-concave" rule. The pattern of joint congruence in Au. sediba contributes to other data on the foot and ankle suggesting that the lateral side of the foot was more mobile than the medial side, which is consistent with suggestions of increased medial weight transfer associated with hyperpronation. Am J Phys Anthropol 160:446-457, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Complying with current Joint Commission Statement of Conditions (SOC) requirements.

    PubMed

    Erickson, D; Berek, B; Mills, G

    1997-01-01

    This Technical Document has been developed to provide the reader with insight into the Joint Commission on Accreditation of Healthcare Organizations' (JCAHO) Statement of Conditions (SOC) process and recent changes for completing the SOC for Business Occupancies. The intent of this document is not to replace the instructions in Part 1 of the SOC or to give a complete review of the National Fire Protection Agency's (NFPA) Life Safety Code for health care or business occupancies, but rather to complement them.

  11. Functional outcome from sacroiliac joint prolotherapy in patients with sacroiliac joint instability.

    PubMed

    Hoffman, Martin D; Agnish, Vikram

    2018-04-01

    Examine the effectiveness of sacroiliac (SI) joint prolotherapy for SI joint instability, and characterize the patients most likely to benefit from this treatment. Retrospective cohort study. Department of Veterans Affairs outpatient physical medicine clinic. Patients referred for low back pain and diagnosed with SI joint instability received a series of three SI joint prolotherapy injections (15% dextrose in lidocaine) at approximately a one-month interval. The outcome of those completing treatment was retrospectively examined, and characteristics were compared between those with at least a minimum clinically important improvement and those without improvement. Patients completed the Oswestry Disability Index (ODI) before treatment was initiated, immediately preceding each prolotherapy injection, and at 3-4 month follow-up. Of 103 treated patients returning for post-treatment follow-up at a median of 117 days, 24 (23%) showed a minimum clinically important improvement despite a median of 2 years with low back pain and a mean (±SD) pre-intervention ODI of 54 ± 15 points. Much of the improvement was evident after the initial prolotherapy injection, and a 15-point improvement in ODI prior to the second prolotherapy injection had a sensitivity of 92% and specificity of 80% for determining which patients would improve. A satisfactory proportion of patients with symptomatic SI joint instability as an etiology of low back pain can have clinically meaningful functional gains with prolotherapy treatment. The patients who are not likely to improve with prolotherapy are generally evident by lack of improvement following the initial prolotherapy injection. Published by Elsevier Ltd.

  12. Comparison of the use of a notched wedge joint vs. traditional butt joints in Connecticut : phase 1 report.

    DOT National Transportation Integrated Search

    2008-05-14

    Performance of Hot Mix Asphalt (HMA) longitudinal joints have been an : item of increasing scrutiny in Connecticut. The traditional butt joint : has typically been the method used in Connecticut. These joints have : been reportedly opening up creatin...

  13. The sacroiliac joint: anatomy, physiology and clinical significance.

    PubMed

    Forst, Stacy L; Wheeler, Michael T; Fortin, Joseph D; Vilensky, Joel A

    2006-01-01

    The sacroiliac joint (SIJ) is a putative source of low back pain. The objective of this article is to provide clinicians with a concise review of SIJ structure and function, diagnostic indicators of SIJ-mediated pain, and therapeutic considerations. The SIJ is a true diarthrodial joint with unique characteristics not typically found in other diarthrodial joints. The joint differs with others in that it has fibrocartilage in addition to hyaline cartilage, there is discontinuity of the posterior capsule, and articular surfaces have many ridges and depressions. The sacroiliac joint is well innervated. Histological analysis of the sacroiliac joint has verified the presence of nerve fibers within the joint capsule and adjoining ligaments. It has been variously described that the sacroiliac joint receives its innervation from the ventral rami of L4 and L5, the superior gluteal nerve, and the dorsal rami of L5, S1, and S2, or that it is almost exclusively derived from the sacral dorsal rami. Even though the sacroiliac joint is a known putative source of low back and lower extremity pain, there are few findings that are pathognomonic of sacroiliac joint pain. The controlled diagnostic blocks utilizing the International Association for the Study of Pain (IASP) criteria demonstrated the prevalence of pain of sacroiliac joint origin in 19% to 30% of the patients suspected to have sacroiliac joint pain. Conservative management includes manual medicine techniques, pelvic stabilization exercises to allow dynamic postural control, and muscle balancing of the trunk and lower extremities. Interventional treatments include sacroiliac joint, intra-articular joint injections, radiofrequency neurotomy, prolotherapy, cryotherapy, and surgical treatment. The evidence for intra-articular injections and radiofrequency neurotomy has been shown to be limited in managing sacroiliac joint pain.

  14. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    PubMed

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Nikolaus Rüdinger (1832-1896), His Description of Joint Innervation in 1857, and the History of Surgical Joint Denervation.

    PubMed

    Gohritz, Andreas; Kaiser, Erich; Guggenheim, Merlin; Dellon, Arnold Lee

    2018-01-01

     Selective joint denervation has become a reliable palliative treatment, especially for painful joints in the upper and lower extremity.  This article highlights the life and work of Nikolaus Rüdinger (1832-1896) who first described joint innervation which became the basis of later techniques of surgical joint denervation. The historical evolution of this method is outlined.  Rüdinger made a unique career from apprentice barber to military surgeon and anatomy professor in Munich, Germany. His first description of articular innervation of temporomandibular, shoulder, elbow, wrist, finger, sacroiliac, hip, knee, ankle, foot, and toe joints in 1857 stimulated the subsequent history of surgical joint denervation. Comparing his investigations with modern joint denervation methods, developed by pioneers like Albrecht Wilhelm or A. Lee Dellon, shows his great exactitude and anatomical correspondence despite different current terminology. Clinical series of modern surgical joint denervations reveal success rates of up to 80% with reliable long-term results.  The history of joint denervation with Rüdinger as its important protagonist offers inspiring insights into the evolution of surgical techniques and exemplifies the value of descriptive functional anatomy, even if surgical application may not have been realized until a century later. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder head and block of the engine shall be fitted with a metal or metal-clad gasket satisfactory to MSHA...

  17. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder head and block of the engine shall be fitted with a metal or metal-clad gasket satisfactory to MSHA...

  18. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder head and block of the engine shall be fitted with a metal or metal-clad gasket satisfactory to MSHA...

  19. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder head and block of the engine shall be fitted with a metal or metal-clad gasket satisfactory to MSHA...

  20. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder head and block of the engine shall be fitted with a metal or metal-clad gasket satisfactory to MSHA...