Sample records for joints results showed

  1. Results of arthroscopic joint debridement in different stages of chondromalacia of the knee joint.

    PubMed

    Krüger, T; Wohlrab, D; Birke, A; Hein, W

    2000-01-01

    A retrospective study was performed of 161 patients who had undergone arthroscopic operation for chondromalacia of the knee joint. After an average follow-up period of 40 (range 10-72) months, patients with severe articular cartilage lesions who had undergone articular lavage alone showed significantly poorer results (P < 0.001). With the same stage of chondromalacia and having undergone the same surgical procedure, younger patients showed better results than older patients. The more effective interruption of the circulus vitiosus during the development of degenerative joint diseases is the primary cause for better results achieved by mechanical debridement of the joint for patients suffering from grade 2 or higher. According to the literature, aggressive subchondral abrasion in severely degenerated knees does not show any benefits. Apparently, the success of the therapy depends to a great extent on the inferiority of the potential degenerative regenerate (lack of capacity of intrinsic regeneration of the hyaline cartilage) as well as on the grade and the progression of chondromalacia. Almost every second patient suffering from grade 4 chondromalacia complained of recurrent pain 1 year postoperatively. One of every 6 patients received a knee joint prosthesis within the 1st year. Therefore, the patients' preoperative expectations have to be clearly objectified. The surgical procedure as an operation with a low complication risk can also be justified as a temporary alternative to total knee arthroplasty in patients suffering from a high-grade degeneration of the joint.

  2. The Fate of DDH Hips Showing Cartilaginous or Fibrous Tissue-filled Joint Spaces Following Primary Reduction.

    PubMed

    Kim, Hui Taek; Lee, Tae Hoon; Ahn, Tae Young; Jang, Jae Hoon

    Because the use of magnetic resonance imaging is still not universal for the patients with developmental dysplasia of the hip patients, orthopaedists do not generally distinguish widened joint spaces which are "empty" after primary treatment (and therefore still reducible), from those which are filled and much more difficult to treat. To date no studies have focused on the latter hips. We treated and observed the outcomes for 19 hips which showed filled joint spaces after primary treatment. We retrospectively reviewed 19 cases of developmental dysplasia of the hip: (1) who showed a widened joint space on radiographs after primary treatment; and (2) whose magnetic resonance imaging showed that the widened joint space was accompanied by acetabular cartilage hypertrophy and/or was filled with fibrous tissues. All patients were over 1 year old at the time of primary reduction (reduction was closed in 4 patients, open in 6, and open with pelvic osteotomy in 9). Thirteen patients received at least 1 secondary treatment. Final results were classified using a modified Severin classification. Final outcomes were satisfactory in 10 (52.6%) and unsatisfactory in 9 (47.4%). The widened joint spaces gradually filled with bone, resulting in a shallow acetabulum in the patients with unsatisfactory results. Of 9 patients who underwent combined pelvic osteotomy at the time of primary reduction, results were satisfactory in 6 (66.7%), whereas all patients who had only closed or open primary reduction had unsatisfactory results. Combined pelvic osteotomy at the time of primary reduction is advisable in hips with widened joint spaces. However, hips with filled joint spaces after primary treatment often have unsatisfactory results even after additional pelvic and/or femoral osteotomy. Level IV-prognostic study.

  3. 11. Corner of Derrick Showing Bolted Joints and DoublePipe/Wood Beam ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Corner of Derrick Showing Bolted Joints and Double-Pipe/Wood Beam Support For Bull Wheel, Looking Southeast - David Renfrew Oil Rig, East side of Connoquenessing Creek, 0.4 mile North of confluence with Thorn Creek, Renfrew, Butler County, PA

  4. Results and Analysis from Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer

    2010-01-01

    This joint mobility KC lecture included information from two papers, "A Method for and Issues Associated with the Determination of Space Suit Joint Requirements" and "Results and Analysis from Space Suit Joint Torque Testing," as presented for the International Conference on Environmental Systems in 2009 and 2010, respectively. The first paper discusses historical joint torque testing methodologies and approaches that were tested in 2008 and 2009. The second paper discusses the testing that was completed in 2009 and 2010.

  5. Cooled radiofrequency denervation for treatment of sacroiliac joint pain: two-year results from 20 cases

    PubMed Central

    Ho, Kok-Yuen; Hadi, Mohamed Abdul; Pasutharnchat, Koravee; Tan, Kian-Hian

    2013-01-01

    Background Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergy™ cooled radiofrequency system for sacroiliac joint pain. Methods The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergy™ cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction. Results Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale). Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was “improved” (1.4 ± 1.5), and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure. Conclusion Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain. PMID:23869175

  6. Results and Analysis from Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer E.; Aitchison, Lindsay

    2009-01-01

    A space suit s mobility is critical to an astronaut s ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. The term mobility, with respect to space suits, is defined in terms of two key components: joint range of motion and joint torque. Individually these measures describe the path which in which a joint travels and the force required to move it through that path. Previous space suits mobility requirements were defined as the collective result of these two measures and verified by the completion of discrete functional tasks. While a valid way to impose mobility requirements, such a method does necessitate a solid understanding of the operational scenarios in which the final suit will be performing. Because the Constellation space suit system requirements are being finalized with a relatively immature concept of operations, the Space Suit Element team elected to define mobility in terms of its constituent parts to increase the likelihood that the future pressure garment will be mobile enough to enable a broad scope of undefined exploration activities. The range of motion requirements were defined by measuring the ranges of motion test subjects achieved while performing a series of joint maximizing tasks in a variety of flight and prototype space suits. The definition of joint torque requirements has proved more elusive. NASA evaluated several different approaches to the problem before deciding to generate requirements based on unmanned joint torque evaluations of six different space suit configurations being articulated through 16 separate joint movements. This paper discusses the experiment design, data analysis and results, and the process used to determine the final values for the Constellation pressure garment joint torque requirements.

  7. Subjective results of joint lavage and viscosupplementation in hemophilic arthropathy

    PubMed Central

    de Rezende, Márcia Uchoa; Rosa, Thiago Bittencourt Carvalho; Pasqualin, Thiago; Frucchi, Renato; Okazaki, Erica; Villaça, Paula Ribeiro

    2015-01-01

    OBJECTIVE: To assess whether joint lavage, viscosupplementation and triamcinolone improve joint pain, function and quality of life in patients with severe hemophilic arthropathy. METHODS: Fourteen patients with knee and/or ankle hemophilic arthritis with and without involvement of other joints underwent joint lavage and subsequent injection of hylan G-F20 and triamcinolone in all affected joints. The patients answered algo-functional questionnaires (Lequesne and WOMAC), visual analog scale for pain (VAS) and SF-36 preoperatively, and at one, three, six and twelve months postoperatively. RESULTS: Sixteen knees, 15 ankles, 8 elbows and one shoulder were treated in 14 patients. Six patients had musculoskeletal bleeding [ankle (1), leg muscle (2) and knees (4)] at 3 months affecting the results. Pain did not improve significantly. Function improved (WOMAC p=0.02 and Lequesne p=0.01). The physical component of SF-36 improved at all time points except at 3 months, with best results at one-year follow-up (baseline = 33.4; 1 month = 39.6; 3 months= 37.6; 6 months 39.6 and 1 year = 44.6; p < 0.001). CONCLUSION: Joint lavage followed by injection of triamcinolone and hylan G-F20 improves function and quality of life progressively up to a year, even in severe hemophilic arthropathy. Level of Evidence IV, Case Series. PMID:26207096

  8. Distraction for proximal interphalangeal joint contractures: long-term results.

    PubMed

    Houshian, Shirzad; Jing, Shan Shan; Kazemian, Gholam Hussein; Emami-Moghaddam-Tehrani, Mohammad

    2013-10-01

    To report the medium- to long-term outcomes of joint distraction using a unilateral external fixator in the treatment of chronic post-traumatic proximal interphalangaeal (PIP) joint contractures. Between September 2001 and October 2011, 94 consecutive patients (98 PIP joints) with a mean age of 43 years (range, 17-69 y) were treated with external fixation for chronic flexion deformity of the PIP joint from trauma. The average time from injury to surgery was 48 months (range, 6-84 mo), and the duration of joint distraction was 10 days (range, 7-22 d). Patients were followed for a mean period of 54 months (range, 12-72 mo). The average gain in joint flexion was 25° and in joint extension was 40°. The mean improvement in the active range of movement was 67° (range. 30°-90°). There was no loss of motion on the latest follow-up. Patients younger than 40 years fared slightly better than those older than 40 years. Two patients developed swelling, pain, and erythema during treatment, which resolved upon temporarily stopping the distraction process. There were 12 cases of superficial pin-site infections, which were managed conservatively without serious complications or adverse outcome. External fixation is a simple and effective treatment modality for chronic traumatic PIP joint contractures with good predictable medium- to long-term results. Careful patient selection and monitoring are required. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Results and Analysis from Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer

    2010-01-01

    A space suit's mobility is critical to an astronaut's ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. Mobility can be broken down into two parts: range of motion (ROM) and torque. These two measurements describe how the suit moves and how much force it takes to move. Two methods were chosen to define mobility requirements for the Constellation Space Suit Element (CSSE). One method focuses on range of motion and the second method centers on joint torque. A joint torque test was conducted to determine a baseline for current advanced space suit joint torques. This test utilized the following space suits: Extravehicular Mobility Unit (EMU), Advanced Crew Escape Suit (ACES), I-Suit, D-Suit, Enhanced Mobility (EM)- ACES, and Mark III (MK-III). Data was collected data from 16 different joint movements of each suit. The results were then reviewed and CSSE joint torque requirement values were selected. The focus of this paper is to discuss trends observed during data analysis.

  10. Results of a joint NOAA/NASA sounder simulation study

    NASA Technical Reports Server (NTRS)

    Phillips, N.; Susskind, Joel; Mcmillin, L.

    1988-01-01

    This paper presents the results of a joint NOAA and NASA sounder simulation study in which the accuracies of atmospheric temperature profiles and surface skin temperature measuremnents retrieved from two sounders were compared: (1) the currently used IR temperature sounder HIRS2 (High-resolution Infrared Radiation Sounder 2); and (2) the recently proposed high-spectral-resolution IR sounder AMTS (Advanced Moisture and Temperature Sounder). Simulations were conducted for both clear and partial cloud conditions. Data were analyzed at NASA using a physical inversion technique and at NOAA using a statistical technique. Results show significant improvement of AMTS compared to HIRS2 for both clear and cloudy conditions. The improvements are indicated by both methods of data analysis, but the physical retrievals outperform the statistical retrievals.

  11. Sacroiliac Joint Fusion: One Year Clinical and Radiographic Results Following Minimally Invasive Sacroiliac Joint Fusion Surgery

    PubMed Central

    Kube, Richard A.; Muir, Jeffrey M.

    2016-01-01

    Background: Recalcitrant sacroiliac joint pain responds well to minimally-invasive surgical (MIS) techniques, although long-term radiographic and fusion data are limited. Objective: To evaluate the one-year clinical results from a cohort of patients with chronic sacroiliac (SI) joint pain unresponsive to conservative therapies who have undergone minimally invasive SI joint fusion. Methods: SI joint fusion was performed between May 2011 and January 2014. Outcomes included radiographic assessment of fusion status, leg and back pain severity via visual analog scale (VAS), disability via Oswestry Disability Index (ODI) and complication rate. Outcomes were measured at baseline and at follow-up appointments 6 months and 12 months post-procedure. Results: Twenty minimally invasive SI joint fusion procedures were performed on 18 patients (mean age: 47.2 (14.2), mean BMI: 29.4 (5.3), 56% female). At 12 months, the overall fusion rate was 88%. Back and leg pain improved from 81.7 to 44.1 points (p<0.001) and from 63.6 to 27.7 points (p=0.001), respectively. Disability scores improved from 61.0 to 40.5 (p=0.009). Despite a cohort containing patients with multiple comorbidities and work-related injuries, eight patients (50%) achieved the minimal clinically important difference (MCID) in back pain at 12 months, with 9 (69%) patients realizing this improvement in leg pain and 8 (57%) realizing the MCID in ODI scores at 12 months. No major complications were reported. Conclusion: Minimally invasive SI joint surgery is a safe and effective procedure, with a high fusion rate, a satisfactory safety profile and significant improvements in pain severity and disability reported through 12 months post-procedure. PMID:28144378

  12. Joint Soviet-American experiment on hypokinesia: Experimental results

    NASA Technical Reports Server (NTRS)

    Burovskiy, N. N.

    1979-01-01

    Comprehensive results are reported from the Soviet portion of a joint Soviet-American experiment involving hypokinesia. The main emphases are on chemical analyses of blood and urine, functional tests, and examination of the cardiovascular system by electrocardiography, echocardiography, and plethysmography.

  13. CONICAL, RADIOGRAPHIC, AND PATIENT-REPORTED RESULTS OF SURFACE REPLACING PROXIMAL INTERPHALANGEAL JOINT ARTHROPLASTY OF THE HAND

    PubMed Central

    Amirtharajah, Mohana; Fufa, Duretti; Lightdale, Nina; Weiland, Andew

    2011-01-01

    The purpose of this study was to evaluate the one-year clinical, radiologic and patient-reported results of surface-replacing proximal interphalangeal joint arthroplasty (SR-PIP) of the hand. Fifteen patients with 18 joints underwent the procedure, and nine patients with 11 joints had follow-up of at least one year's duration. Of these joints, six had a diagnosis of osteoarthritis with no history of trauma, three had post-traumatic arthritis, one had psoriatic arthritis, and one had erosive arthritis. The mean clinical follow-up was at 3.3 years, and the mean radiographic follow-up was at 3.1 years. The average post-operative gain in range of motion at the PIP joint was 28 degrees and was statistically significant. Six patients completed self-reported questionnaires at a mean of 4.8 years post-operatively. The mean Disabilities of the Arm, Shoulder and Hand (DASH) score post-operatively was 17, and the Michigan Hand Questionnaire (MHQ) score for overall satisfaction was 70. There were three complications but only one reoperation. Seven of 11 joints showed some evidence of subsidence on follow-up radiographic examination. However, no joints were revised sec-ondary to loosening. Longer follow-up is needed to determine if this observable radiologic subsidence leads to symptomatic loosening of the implant PMID:22096433

  14. Description of and preliminary tests results for the Joint Damping Experiment (JDX)

    NASA Technical Reports Server (NTRS)

    Bingham, Jeffrey G.; Folkman, Steven L.

    1995-01-01

    An effort is currently underway to develop an experiment titled joint Damping E_periment (JDX) to fly on the Space Shuttle as Get Away Special Payload G-726. This project is funded by NASA's IN-Space Technology Experiments Program and is scheduled to fly in July 1995 on STS-69. JDX will measure the influence of gravity on the structural damping of a three bay truss having clearance fit pinned joints. Structural damping is an important parameter in the dynamics of space structures. Future space structures will require more precise knowledge of structural damping than is currently available. The mission objectives are to develop a small-scale shuttle flight experiment that allows researchers to: (1) characterize the influence of gravity and joint gaps on structural damping and dynamic behavior of a small-scale truss model, and (2) evaluate the applicability of low-g aircraft test results for predicting on-orbit behavior. Completing the above objectives will allow a better understanding and/or prediction of structural damping occurring in a pin jointed truss. Predicting damping in joints is quite difficult. One of the important variables influencing joint damping is gravity. Previous work has shown that gravity loads can influence damping in a pin jointed truss structure. Flying this experiment as a GAS payload will allow testing in a microgravity environment. The on-orbit data (in micro-gravity) will be compared with ground test results. These data will be used to help develop improved models to predict damping due to pinned joints. Ground and low-g aircraft testing of this experiment has been completed. This paper describes the experiment and presents results of both ground and low-g aircraft tests which demonstrate that damping of the truss is dramatically influenced by gravity.

  15. Sacroiliac Joint Fusion: One Year Clinical and Radiographic Results Following Minimally Invasive Sacroiliac Joint Fusion Surgery.

    PubMed

    Kube, Richard A; Muir, Jeffrey M

    2016-01-01

    Recalcitrant sacroiliac joint pain responds well to minimally-invasive surgical (MIS) techniques, although long-term radiographic and fusion data are limited. To evaluate the one-year clinical results from a cohort of patients with chronic sacroiliac (SI) joint pain unresponsive to conservative therapies who have undergone minimally invasive SI joint fusion. SI joint fusion was performed between May 2011 and January 2014. Outcomes included radiographic assessment of fusion status, leg and back pain severity via visual analog scale (VAS), disability via Oswestry Disability Index (ODI) and complication rate. Outcomes were measured at baseline and at follow-up appointments 6 months and 12 months post-procedure. Twenty minimally invasive SI joint fusion procedures were performed on 18 patients (mean age: 47.2 (14.2), mean BMI: 29.4 (5.3), 56% female). At 12 months, the overall fusion rate was 88%. Back and leg pain improved from 81.7 to 44.1 points (p<0.001) and from 63.6 to 27.7 points (p=0.001), respectively. Disability scores improved from 61.0 to 40.5 (p=0.009). Despite a cohort containing patients with multiple comorbidities and work-related injuries, eight patients (50%) achieved the minimal clinically important difference (MCID) in back pain at 12 months, with 9 (69%) patients realizing this improvement in leg pain and 8 (57%) realizing the MCID in ODI scores at 12 months. No major complications were reported. Minimally invasive SI joint surgery is a safe and effective procedure, with a high fusion rate, a satisfactory safety profile and significant improvements in pain severity and disability reported through 12 months post-procedure.

  16. Current practice patterns in conservative thumb CMC joint care: survey results.

    PubMed

    O'Brien, Virginia H; McGaha, Jamie L

    2014-01-01

    Cross-sectional descriptive survey Best practice for conservative clinical care pathways is not well outlined in the literature for patients with thumb carpometacarpal joint (CMCJ) pain. This self-report survey investigated the current practice patterns of assessments and conservative interventions for the painful thumb CMCJ among hand therapists. An online survey was distributed to members of the American Society of Hand Therapists (ASHT). Questions were included about evaluation measures and intervention techniques used for this population. A descriptive analysis was completed of the results. A total of 23.5% of the ASHT membership responded to the survey. Results were categorized using the International Classification of Functioning and Disability domains as a framework. The survey results report varying use of evaluation measures, therapeutic interventions, including orthotic fabrication, joint protection and patient education all therapeutic interventional techniques, and modalities. Therapists use a comprehensive array of evaluation measures and interventions for body functions and structures in the care of thumb CMC pain. In contrast, more consistent use is needed of psychometrically-sound functional outcome measures that show change in activities and participation. This survey highlights areas to employ current evidence, as well as, future research should address environmental factors and personal factors for this population Not applicable. Copyright © 2014 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  17. Analytical and Numerical Results for an Adhesively Bonded Joint Subjected to Pure Bending

    NASA Technical Reports Server (NTRS)

    Smeltzer, Stanley S., III; Lundgren, Eric

    2006-01-01

    A one-dimensional, semi-analytical methodology that was previously developed for evaluating adhesively bonded joints composed of anisotropic adherends and adhesives that exhibit inelastic material behavior is further verified in the present paper. A summary of the first-order differential equations and applied joint loading used to determine the adhesive response from the methodology are also presented. The method was previously verified against a variety of single-lap joint configurations from the literature that subjected the joints to cases of axial tension and pure bending. Using the same joint configuration and applied bending load presented in a study by Yang, the finite element analysis software ABAQUS was used to further verify the semi-analytical method. Linear static ABAQUS results are presented for two models, one with a coarse and one with a fine element meshing, that were used to verify convergence of the finite element analyses. Close agreement between the finite element results and the semi-analytical methodology were determined for both the shear and normal stress responses of the adhesive bondline. Thus, the semi-analytical methodology was successfully verified using the ABAQUS finite element software and a single-lap joint configuration subjected to pure bending.

  18. Integrating Quantitative and Qualitative Results in Health Science Mixed Methods Research Through Joint Displays

    PubMed Central

    Guetterman, Timothy C.; Fetters, Michael D.; Creswell, John W.

    2015-01-01

    PURPOSE Mixed methods research is becoming an important methodology to investigate complex health-related topics, yet the meaningful integration of qualitative and quantitative data remains elusive and needs further development. A promising innovation to facilitate integration is the use of visual joint displays that bring data together visually to draw out new insights. The purpose of this study was to identify exemplar joint displays by analyzing the various types of joint displays being used in published articles. METHODS We searched for empirical articles that included joint displays in 3 journals that publish state-of-the-art mixed methods research. We analyzed each of 19 identified joint displays to extract the type of display, mixed methods design, purpose, rationale, qualitative and quantitative data sources, integration approaches, and analytic strategies. Our analysis focused on what each display communicated and its representation of mixed methods analysis. RESULTS The most prevalent types of joint displays were statistics-by-themes and side-by-side comparisons. Innovative joint displays connected findings to theoretical frameworks or recommendations. Researchers used joint displays for convergent, explanatory sequential, exploratory sequential, and intervention designs. We identified exemplars for each of these designs by analyzing the inferences gained through using the joint display. Exemplars represented mixed methods integration, presented integrated results, and yielded new insights. CONCLUSIONS Joint displays appear to provide a structure to discuss the integrated analysis and assist both researchers and readers in understanding how mixed methods provides new insights. We encourage researchers to use joint displays to integrate and represent mixed methods analysis and discuss their value. PMID:26553895

  19. Arthroscopic procedures and therapeutic results of anatomical reconstruction of the coracoclavicular ligaments for acromioclavicular Joint dislocation.

    PubMed

    Takase, K; Yamamoto, K

    2016-09-01

    Surgical treatment is recommended for type 5 acromioclavicular joint dislocation on Rockwood's classification. We believe that anatomic repair of the coracoclavicular ligaments best restores the function of the acromioclavicular joint. We attempted to correctly reconstruct the anatomy of the coracoclavicular ligaments under arthroscopy, and describe the minimally invasive arthroscopic procedure. There were 22 patients; mean age at surgery, 38.1 years. Mean time to surgery was 13.2 days. Mean follow-up was 3 years 2 months. The palmaris longus tendon was excised from the ipsilateral side to replace the conoid ligament, while artificial ligament was used for reconstructing the trapezoid ligament. Both ligament reconstructions were performed arthroscopically. No temporary fixation of the acromioclavicular joint was performed. On postoperative radiographic evaluation, 4 patients showed subluxation and 2 showed dislocation of the acromioclavicular joint; the other 16 patients had maintained reduction at the final consultation. MR images 1year after surgery clearly revealed the reconstructed ligaments in 19 patients. Only 1 patient showed osteoarthritis of the acromioclavicular joint. Although it requires resection of the ipsilateral palmaris longus for grafting, we believe that anatomic reconstruction of both coracoclavicular ligaments best restores the function of the acromioclavicular joint. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Disturbed Cartilage and Joint Homeostasis Resulting From a Loss of Mitogen-Inducible Gene 6 in a Mouse Model of Joint Dysfunction

    PubMed Central

    Pest, Michael A.; Russell, Bailey A.; Zhang, Yu-Wen; Jeong, Jae-Wook; Beier, Frank

    2017-01-01

    Objective Mitogen-inducible gene 6 (MIG-6) regulates epidermal growth factor receptor (EGFR) signaling in synovial joint tissues. Whole-body knockout of the Mig6 gene in mice has been shown to induce osteoarthritis and joint degeneration. To evaluate the role of chondrocytes in this process, Mig6 was conditionally deleted from Col2a1-expressing cell types in the cartilage of mice. Methods Bone and cartilage in the synovial joints of cartilage-specific Mig6-deleted (knockout [KO]) mice and control littermates were compared. Histologic staining and immunohistochemical analyses were used to evaluate joint pathology as well as the expression of key extracellular matrix and regulatory proteins. Calcified tissue in synovial joints was assessed by micro–computed tomography (micro-CT) and whole-skeleton staining. Results Formation of long bones was found to be normal in KO animals. Cartilage thickness and proteoglycan staining of articular cartilage in the knee joints of 12-week-old KO mice were increased as compared to controls, with higher cellularity throughout the tissue. Radiopaque chondro-osseous nodules appeared in the knees of KO animals by 12 weeks of age and progressed to calcified bone–like tissue by 36 weeks of age. Nodules were also observed in the spine of 36-week-old animals. Erosion of bone at ligament entheses was evident by 12 weeks of age, by both histologic and micro-CT assessment. Conclusion MIG-6 expression in chondrocytes is important for the maintenance of cartilage and joint homeostasis. Dysregulation of EGFR signaling in chondrocytes results in anabolic activity in cartilage, but erosion of ligament entheses and the formation of ectopic chondro-osseous nodules severely disturb joint physiology. PMID:24966136

  1. One- and multi-segment foot models lead to opposite results on ankle joint kinematics during gait: Implications for clinical assessment.

    PubMed

    Pothrat, Claude; Authier, Guillaume; Viehweger, Elke; Berton, Eric; Rao, Guillaume

    2015-06-01

    Biomechanical models representing the foot as a single rigid segment are commonly used in clinical or sport evaluations. However, neglecting internal foot movements could lead to significant inaccuracies on ankle joint kinematics. The present study proposed an assessment of 3D ankle kinematic outputs using two distinct biomechanical models and their application in the clinical flat foot case. Results of the Plug in Gait (one segment foot model) and the Oxford Foot Model (multisegment foot model) were compared for normal children (9 participants) and flat feet children (9 participants). Repeated measures of Analysis of Variance have been performed to assess the Foot model and Group effects on ankle joint kinematics. Significant differences were observed between the two models for each group all along the gait cycle. In particular for the flat feet group, opposite results between the Oxford Foot Model and the Plug in Gait were revealed at heelstrike, with the Plug in Gait showing a 4.7° ankle dorsal flexion and 2.7° varus where the Oxford Foot Model showed a 4.8° ankle plantar flexion and 1.6° valgus. Ankle joint kinematics of the flat feet group was more affected by foot modeling than normal group. Foot modeling appeared to have a strong influence on resulting ankle kinematics. Moreover, our findings showed that this influence could vary depending on the population. Studies involving ankle joint kinematic assessment should take foot modeling with caution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Horizontal slip along Alleghanian joints of the Appalachian plateau: evidence showing that mild penetrative strain does little to change the pristine appearance of early joints

    NASA Astrophysics Data System (ADS)

    Engelder, Terry; Haith, Benjamin F.; Younes, Amgad

    2001-07-01

    Some Alleghanian joints in black shales of the Geneseo and Middlesex Formations of the Catskill Delta complex, Finger Lakes district, New York, slipped horizontally up to 8 cm. Horizontal slip is measured by the offset of ENE-striking joints. Alleghanian joints striking 330-350° display a right-lateral slip with an average value of 1.9 cm, while joints striking 004-010° slip in the left-lateral sense with an average value of 1.3 cm. The maximum horizontal stress (SH) driving this slip falls between 350° and 004°, the orientation of local Alleghanian layer-parallel shortening as indicated by both disjunctive and pencil cleavage. By commonality of orientation, we infer that slip on Alleghanian joints is driven contemporaneously with layer-parallel shortening. If so, the offset ENE-striking joints predate the Alleghanian stress field. These observations mean that both pre-Alleghanian and early Alleghanian joints persist through a period of penetrative strain.

  3. Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

    NASA Technical Reports Server (NTRS)

    Verhage, Joseph M.; Bower, Mark V.; Gilbert, Paul A. (Technical Monitor)

    2001-01-01

    The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

  4. Joint hyperlaxity prevents relapses in clubfeet treated by Ponseti method-preliminary results.

    PubMed

    Cosma, Dan Ionuţ; Corbu, Andrei; Nistor, Dan Viorel; Todor, Adrian; Valeanu, Madalina; Morcuende, Jose; Man, Sorin

    2018-05-07

    The aim of the study was to evaluate the role of joint hyperlaxity (by Beighton score) as a protective factor for clubfoot relapse. Patients with idiopathic clubfoot treated with the Ponseti method between January 2004 and December 2012, without other congenital foot deformity, and not previously treated by open surgery were included in either the Relapse group (n = 23) if it was a clubfoot relapse or the Control group (n = 19) if no relapse was noted. Joint laxity was evaluated using the Beighton score at the latest follow-up against the Normal group (n = 22, children matched by sex and age without clubfoot deformity). We found a significantly higher joint laxity in the Control group (4.58, 95% confidence interval [CI]: 2.1-7.06) as compared to the Relapse (3.17, 95% CI: 1.53-4.81, p = 0.032) and Normal (3.14, 95% CI: 1.78-4.5, p = 0.03) groups. The univariate logistic regression showed a 5.28-times increase in the risk of relapse for a Beighton score lower than 4/9 points (odds ratio = 5.28; 95% CI = 1.29-21.5; p = 0.018). Joint hyperlaxity could be a protective factor for clubfoot relapse.

  5. Integrating Quantitative and Qualitative Results in Health Science Mixed Methods Research Through Joint Displays.

    PubMed

    Guetterman, Timothy C; Fetters, Michael D; Creswell, John W

    2015-11-01

    Mixed methods research is becoming an important methodology to investigate complex health-related topics, yet the meaningful integration of qualitative and quantitative data remains elusive and needs further development. A promising innovation to facilitate integration is the use of visual joint displays that bring data together visually to draw out new insights. The purpose of this study was to identify exemplar joint displays by analyzing the various types of joint displays being used in published articles. We searched for empirical articles that included joint displays in 3 journals that publish state-of-the-art mixed methods research. We analyzed each of 19 identified joint displays to extract the type of display, mixed methods design, purpose, rationale, qualitative and quantitative data sources, integration approaches, and analytic strategies. Our analysis focused on what each display communicated and its representation of mixed methods analysis. The most prevalent types of joint displays were statistics-by-themes and side-by-side comparisons. Innovative joint displays connected findings to theoretical frameworks or recommendations. Researchers used joint displays for convergent, explanatory sequential, exploratory sequential, and intervention designs. We identified exemplars for each of these designs by analyzing the inferences gained through using the joint display. Exemplars represented mixed methods integration, presented integrated results, and yielded new insights. Joint displays appear to provide a structure to discuss the integrated analysis and assist both researchers and readers in understanding how mixed methods provides new insights. We encourage researchers to use joint displays to integrate and represent mixed methods analysis and discuss their value. © 2015 Annals of Family Medicine, Inc.

  6. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    PubMed

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Public priorities for joint pain research: results from a general population survey

    PubMed Central

    Carter, Pam; Ong, Bie Nio; Bedson, John; Jordan, Kelvin P.; Jinks, Clare

    2012-01-01

    Objective. We aimed to identify the priorities for joint pain research from a large general population survey and identify characteristics associated with these priorities. Methods. A question about research priorities was developed in collaboration with the Arthritis Research UK Primary Care Centre’s Research Users’ Group. The question was embedded in a postal survey to an existing cohort of adults with self-reported joint pain, aged ≥56 years, in North Staffordshire. Respondents were asked to rank their top three priorities for research. Factor mixture modelling was used to determine subgroups of priorities. Results. In all, 1756 (88%) people responded to the survey. Of these, 1356 (77%) gave three priorities for research. Keeping active was rated the top priority by 38%, followed by research around joint replacement (9%) and diet/weight loss (9%). Two clusters of people were identified: 62% preferred lifestyle/self-management topics (e.g. keeping active, weight loss) and 38% preferred medical intervention topics (e.g. joint replacement, tablets). Those who preferred the medical options tended to be older and have hip or foot pain. Conclusion. This study has provided population data on priorities for joint pain research expressed by a large cohort of older people who report joint pain. The most popular topics for research were linked to lifestyle and self-management opportunities. Pharmaceutical and invasive interventions, despite being common topics of research, are of less importance to these respondents than non-medical topics. Specific research questions will be generated from this study with collaboration of the patient’s group. PMID:22886341

  8. Joint Actions of Developmental Toxicants.

    DTIC Science & Technology

    1991-06-01

    antagonistic response may have been the result of poorer absorption of hydroxyurea by the severly malformed embryos, as isoniazid had a much greater...chain carboxylic acids showed concentration additive joint actions for induction of malformation . Combinations of DNA synthesis inhibitors showed...response additive to antagonistic joint actions at malformation -inducing con- centrations. Since each compound inhibits a different enzyme in the process of

  9. Affiliation, joint venture or PSO? Case studies show why provider strategies differ.

    PubMed

    1998-03-01

    Joint venture, affiliation or PSO? Here are three case studies of providers who chose different paths under Medicare risk, plus some key questions you'll want to ask of your own provider organization. Learn from these examples so you'll make the best contracting decisions.

  10. Critical Joints in Large Composite Primary Aircraft Structures. Volume 3: Ancillary Test Results

    NASA Technical Reports Server (NTRS)

    Bunin, Bruce L.; Sagui, R. L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints for composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of a comprehensive ancillary test program are summarized, consisting of single-bolt composite joint specimens tested in a variety of configurations. These tests were conducted to characterize the strength and load deflection properties that are required for multirow joint analysis. The composite material was Toray 300 fiber and Ciba-Geigy 914 resin, in the form of 0.005 and 0.01 inch thick unidirectional tape. Tests were conducted in single and double shear for loaded and unloaded hole configurations under both tensile and compressive loading. Two different layup patterns were examined. All tests were conducted at room temperature. In addition, the results of NASA Standard Toughness Test (NASA RP 1092) are reported, which were conducted for several material systems.

  11. The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.

    2012-01-01

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various

  12. Long-term results of the use of silicone sheets after diskectomy in the temporomandibular joint: clinical, radiographic and histopathologic findings.

    PubMed

    Schliephake, H; Schmelzeisen, R; Maschek, H; Haese, M

    1999-10-01

    The aim of the present study was to evaluate the long-term results of a group of patients who had the disk of the temporomandibular joint (TMJ) removed and permanently replaced by a silicone sheet. The study group comprised 48 patients, treated in the period from 1983 to 1993. In eight patients, the implants had to be removed after an average interval of 5.6 years and they were submitted for histopathological examination. Twenty-five of the 40 patients with silastic implants in place, and five of the 8 patients who had their implants removed, were available for long-term follow-up (mean interval of 7.0 years, SD 2.8 years). Clinical function was rated according to the Helkimo Dysfunction Index and compared to the preoperative findings. Results showed decreased tenderness of muscles and joints to palpation and increased mouth opening, but no statistically significant improvement in joint function. In 4 patients, a decrease in condylar width was found, while another 4 patients presented with thickening of the condyle by appositional bone formation. Histopathology of the failed implants showed scattered fragments of silastic material and dacron fibers with accumulation of histiocytes in immediate contact with the silicone particles and phagocytozed intracellular material. T-lymphocytes were also present in the vicinity of the silicone particles.

  13. The hindlimb in walking horses: 2. Net joint moments and joint powers.

    PubMed

    Clayton, H M; Hodson, E; Lanovaz, J L; Colborne, G R

    2001-01-01

    The objective of the study was to describe net joint moments and joint powers in the equine hindlimb during walking. The subjects were 5 sound horses. Kinematic and force data were collected synchronously and combined with morphometric information to determine net joint moments at each hindlimb joint throughout stance and swing. The results showed that the net joint moment was on the caudal/plantar side of all hindlimb joints at the start of stance when the limb was being actively retracted. It moved to the cranial/dorsal side around 24% stride at the hip and stifle and in terminal stance at the more distal joints. It remained on the cranial/dorsal side of all joints during the first half of swing to provide active limb protraction, then moved to the caudal/plantar aspect to reverse the direction of limb motion prior to ground contact. The hip joint was the main source of energy generation throughout the stride. It was assisted by the tarsal joint in both stance and swing phases and by the fetlock joint during the stance phase. The coffin joint acted as an energy damper during stance, whereas the stifle joint absorbed almost equal amounts of energy in the stance and swing phases. The coffin and fetlock joints absorbed energy as the limb was protracted and retracted during the swing phase, suggesting that their movements were driven by inertial forces. Future studies will apply these findings to detect changes in the energy profiles due to specific soft tissue injuries.

  14. Effects of joints in truss structures

    NASA Technical Reports Server (NTRS)

    Ikegami, R.

    1988-01-01

    The response of truss-type structures for future space applications, such as Large Deployable Reflector (LDR), will be directly affected by joint performance. Some of the objectives of research at BAC were to characterize structural joints, establish analytical approaches that incorporate joint characteristics, and experimentally establish the validity of the analytical approaches. The test approach to characterize joints for both erectable and deployable-type structures was based upon a Force State Mapping Technique. The approach pictorially shows how the nonlinear joint results can be used for equivalent linear analysis. Testing of the Space Station joints developed at LaRC (a hinged joint at 2 Hz and a clevis joint at 2 Hz) successfully revealed the nonlinear characteristics of the joints. The Space Station joints were effectively linear when loaded to plus or minus 500 pounds with a corresponding displacement of about plus or minus 0.0015 inch. It was indicated that good linear joints exist which are compatible with errected structures, but that difficulty may be encountered if nonlinear-type joints are incorporated in the structure.

  15. Deficiency of Hyaluronan Synthase 1 (Has1) Results in Chronic Joint Inflammation and Widespread Intra-Articular Fibrosis in a Murine Model of Knee Joint Cartilage Damage

    PubMed Central

    Chan, Deva D.; Xiao, Wenfeng; Li, Jun; de la Motte, Carol A.; Sandy, John D.; Plaas, Anna

    2015-01-01

    Objective Articular cartilage defects commonly result from traumatic injury and predispose to degenerative joint diseases. To test the hypothesis that aberrant healing responses and chronic inflammation lead to osteoarthritis, we examined spatiotemporal changes in joint tissues after cartilage injury in murine knees. Since intra-articular injection of hyaluronan (HA) can attenuate injury-induced osteoarthritis in wild-type (WT) mice, we investigated a role for HA in the response to cartilage injury in mice lacking HA synthase 1 (Has1−/−). Design Femoral groove cartilage of WT and Has1−/− mice was debrided to generate a non-bleeding wound. Macroscopic imaging, histology, and gene expression were used to evaluate naïve, sham-operated, and injured joints. Results Acute responses (1–2 weeks) in injured joints from WT mice included synovial hyperplasia with HA deposition and joint-wide increases in expression of genes associated with inflammation, fibrosis, and extracellular matrix (ECM) production. By 4 weeks, some resurfacing of damaged cartilage occurred, and early cell responses were normalized. Cartilage damage in Has1−/− mice also induced early responses; however, at 4 weeks, inflammation and fibrosis genes remained elevated with widespread cartilage degeneration and fibrotic scarring in the synovium and joint capsule. Conclusions We conclude that the ineffective repair of injured cartilage in Has1−/− joints can be at least partly explained by the markedly enhanced expression of particular genes in pathways linked to ECM turnover, IL-17/IL-6 cytokine signaling, and apoptosis. Notably, Has1 ablation does not alter gross HA content in the ECM, suggesting that HAS1 has a unique function in the metabolism of inflammatory HA matrices. PMID:26521733

  16. Utilization of Facet Joint and Sacroiliac Joint Interventions in Medicare Population from 2000 to 2014: Explosive Growth Continues!

    PubMed

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Pampati, Vidyasagar; Boswell, Mark V

    2016-10-01

    Increasing utilization of interventional techniques in managing chronic spinal pain, specifically facet joint interventions and sacroiliac joint injections, is a major concern of healthcare policy makers. We analyzed the patterns of utilization of facet and sacroiliac joint interventions in managing chronic spinal pain. The results showed significant increase of facet joint interventions and sacroiliac joint injections from 2000 to 2014 in Medicare FFS service beneficiaries. Overall, the Medicare population increased 35 %, whereas facet joint and sacroiliac joint interventions increased 313.3 % per 100,000 Medicare population with an annual increase of 10.7 %. While the increases were uniform from 2000 to 2014, there were some decreases noted for facet joint interventions in 2007, 2010, and 2013, whereas for sacroiliac joint injections, the decreases were noted in 2007 and 2013. The increases were for cervical and thoracic facet neurolysis at 911.5 % compared to lumbosacral facet neurolysis of 567.8 %, 362.9 % of cervical and thoracic facet joint blocks, 316.9 % of sacroiliac joints injections, and finally 227.3 % of lumbosacral facet joint blocks.

  17. The validation of a human force model to predict dynamic forces resulting from multi-joint motions

    NASA Technical Reports Server (NTRS)

    Pandya, Abhilash K.; Maida, James C.; Aldridge, Ann M.; Hasson, Scott M.; Woolford, Barbara J.

    1992-01-01

    The development and validation is examined of a dynamic strength model for humans. This model is based on empirical data. The shoulder, elbow, and wrist joints were characterized in terms of maximum isolated torque, or position and velocity, in all rotational planes. This data was reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining torque as a function of position and velocity. The isolated joint torque equations were then used to compute forces resulting from a composite motion, in this case, a ratchet wrench push and pull operation. A comparison of the predicted results of the model with the actual measured values for the composite motion indicates that forces derived from a composite motion of joints (ratcheting) can be predicted from isolated joint measures. Calculated T values comparing model versus measured values for 14 subjects were well within the statistically acceptable limits and regression analysis revealed coefficient of variation between actual and measured to be within 0.72 and 0.80.

  18. Adhesive properties and adhesive joints strength of graphite/epoxy composites

    NASA Astrophysics Data System (ADS)

    Rudawska, Anna; Stančeková, Dana; Cubonova, Nadezda; Vitenko, Tetiana; Müller, Miroslav; Valášek, Petr

    2017-05-01

    The article presents the results of experimental research of the adhesive joints strength of graphite/epoxy composites and the results of the surface free energy of the composite surfaces. Two types of graphite/epoxy composites with different thickness were tested which are used to aircraft structure. The single-lap adhesive joints of epoxy composites were considered. Adhesive properties were described by surface free energy. Owens-Wendt method was used to determine surface free energy. The epoxy two-component adhesive was used to preparing the adhesive joints. Zwick/Roell 100 strength device were used to determination the shear strength of adhesive joints of epoxy composites. The strength test results showed that the highest value was obtained for adhesive joints of graphite-epoxy composite of smaller material thickness (0.48 mm). Statistical analysis of the results obtained, the study showed statistically significant differences between the values of the strength of the confidence level of 0.95. The statistical analysis of the results also showed that there are no statistical significant differences in average values of surface free energy (0.95 confidence level). It was noted that in each of the results the dispersion component of surface free energy was much greater than polar component of surface free energy.

  19. Self-aligning exoskeleton hip joint: Kinematic design with five revolute, three prismatic and one ball joint.

    PubMed

    Beil, Jonas; Marquardt, Charlotte; Asfour, Tamim

    2017-07-01

    Kinematic compatibility is of paramount importance in wearable robotic and exoskeleton design. Misalignments between exoskeletons and anatomical joints of the human body result in interaction forces which make wearing the exoskeleton uncomfortable and even dangerous for the human. In this paper we present a kinematically compatible design of an exoskeleton hip to reduce kinematic incompatibilities, so called macro- and micro-misalignments, between the human's and exoskeleton's joint axes, which are caused by inter-subject variability and articulation. The resulting design consists of five revolute, three prismatic and one ball joint. Design parameters such as range of motion and joint velocities are calculated based on the analysis of human motion data acquired by motion capture systems. We show that the resulting design is capable of self-aligning to the human hip joint in all three anatomical planes during operation and can be adapted along the dorsoventral and mediolateral axis prior to operation. Calculation of the forward kinematics and FEM-simulation considering kinematic and musculoskeletal constraints proved sufficient mobility and stiffness of the system regarding the range of motion, angular velocity and torque admissibility needed to provide 50 % assistance for an 80 kg person.

  20. Modeling and optimization of joint quality for laser transmission joint of thermoplastic using an artificial neural network and a genetic algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Xiao; Zhang, Cheng; Li, Pin; Wang, Kai; Hu, Yang; Zhang, Peng; Liu, Huixia

    2012-11-01

    A central composite rotatable experimental design(CCRD) is conducted to design experiments for laser transmission joining of thermoplastic-Polycarbonate (PC). The artificial neural network was used to establish the relationships between laser transmission joining process parameters (the laser power, velocity, clamp pressure, scanning number) and joint strength and joint seam width. The developed mathematical models are tested by analysis of variance (ANOVA) method to check their adequacy and the effects of process parameters on the responses and the interaction effects of key process parameters on the quality are analyzed and discussed. Finally, the desirability function coupled with genetic algorithm is used to carry out the optimization of the joint strength and joint width. The results show that the predicted results of the optimization are in good agreement with the experimental results, so this study provides an effective method to enhance the joint quality.

  1. Btu accounting: Showing results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, K.E.

    1994-10-01

    In the preceding article in this series last month, the author showed how to calculate the energy consumed to make a pound of product. To realize a payoff, however, the results must be presented in graphs or tables that clearly display what has happened. They must call attention to plant performance and ultimately lead to more efficient use of energy. Energy-consumption reporting is particularly valuable when viewed over a period of time. The author recommend compiling data annually and maintaining a ten-year performance history. Four cases are considered: individual plant performance; site performance for sites having more than one plant;more » company performance, for companies having more than one site; and performance based on product, for identical or similar products made at different plants or sites. Of these, individual plant performance is inherently the most useful. It also serves as the best basis for site, company and product performance reports. A key element in energy accounting is the relating of all energy consumption to a common basis. As developed last month in Part 1 in this series, the author chose Btu[sub meth] (i.e., Btu of methane equivalent, expressed as its higher heating value) for this purpose. It represents the amount of methane that would be needed to replace (in the case of fuels) or generate (in the case of steam and power) the energy being used.« less

  2. Conductor and joint test results of JT-60SA CS and EF coils using the NIFS test facility

    NASA Astrophysics Data System (ADS)

    Obana, Tetsuhiro; Takahata, Kazuya; Hamaguchi, Shinji; Kizu, Kaname; Murakami, Haruyuki; Chikaraishi, Hirotaka; Noguchi, Hiroki; Kobuchi, Takashi; Moriuchi, Sadatomo; Imagawa, Shinsaku; Mito, Toshiyuki; Tsuchiya, Katsuhiko; Natsume, Kyohei; Yoshida, Kiyoshi; Nomoto, Kazuhiro; Kim, Tae-hyun

    2016-01-01

    In 2007, JAEA and NIFS launched the test project to evaluate the performance of cable-in-conduit (CIC) conductors and conductor joints for the JT-60SA CS and EF coils. In this project, conductor tests for four types of coil conductor and joint tests for seven types of conductor joint have been conducted for the past eight years using the NIFS test facility. As a result, the test project indicated that the CIC conductors and conductor joints fulfill the design requirement for the CS and EF coils. In addition, the NIFS test facility is expected to be utilized as the test facility for the development of a conductor and conductor joint for the purpose of the DEMO nuclear fusion power plant, provided that the required magnetic field strength is within 9 T.

  3. Strengthening of defected beam-column joints using CFRP.

    PubMed

    Mahmoud, Mohamed H; Afefy, Hamdy M; Kassem, Nesreen M; Fawzy, Tarek M

    2014-01-01

    This paper presents an experimental study for the structural performance of reinforced concrete (RC) exterior beam-column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP). The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered defects include the absence of the transverse reinforcement within the joint core, insufficient bond length for the beam main reinforcement and inadequate spliced implanted column on the joint. Three different strengthening schemes were used to rehabilitate the defected beam-column joints including externally bonded CFRP strips and sheets in addition to near surface mounted (NSM) CFRP strips. The failure criteria including ultimate capacity, mode of failure, initial stiffness, ductility and the developed ultimate strain in the reinforcing steel and CFRP were considered and compared for each group for the control and the CFRP-strengthened specimens. The test results showed that the proposed CFRP strengthening configurations represented the best choice for strengthening the first two defects from the viewpoint of the studied failure criteria. On the other hand, the results of the third group showed that strengthening the joint using NSM strip technique enabled the specimen to outperform the structural performance of the control specimen while strengthening the joints using externally bonded CFRP strips and sheets failed to restore the strengthened joints capacity.

  4. Application of Bionic Design to FRP T-Joints

    NASA Astrophysics Data System (ADS)

    Luo, Guang-Min; Kuo, Chia-Hung

    2017-09-01

    We applied the concepts of bionics to enhance the mechanical strength of fiberglass reinforced plastic T-joints. The failure modes of the designed arthrosis-like and gum-like joints were determined using three-point bending tests and numerical simulations and compared with those of normal T-joints bonded using structural adhesives. In the simulation, we used cohesive elements to simulate the adhesive interface of the structural adhesive. The experimental and simulation results show that the arthrosis-like joint can effectively delay the failure progress and enhance the bonding strength of T-joints, thus confirming that an appropriate bionic design can effectively control the bonding properties of structural adhesives.

  5. Joint attention and language evolution

    NASA Astrophysics Data System (ADS)

    Kwisthout, Johan; Vogt, Paul; Haselager, Pim; Dijkstra, Ton

    2008-06-01

    This study investigates how more advanced joint attentional mechanisms, rather than only shared attention between two agents and an object, can be implemented and how they influence the results of language games played by these agents. We present computer simulations with language games showing that adding constructs that mimic the three stages of joint attention identified in children's early development (checking attention, following attention, and directing attention) substantially increase the performance of agents in these language games. In particular, the rates of improved performance for the individual attentional mechanisms have the same ordering as that of the emergence of these mechanisms in infants' development. These results suggest that language evolution and joint attentional mechanisms have developed in a co-evolutionary way, and that the evolutionary emergence of the individual attentional mechanisms is ordered just like their developmental emergence.

  6. Joint distraction results in clinical and structural improvement of haemophilic ankle arthropathy: a series of three cases.

    PubMed

    Van Meegeren, M E R; Van Veghel, K; De Kleijn, P; Van Roermund, P M; Biesma, D H; Lafeber, F P J G; Roosendaal, G

    2012-09-01

    The incidence of haemophilic arthropathy in multiple joints decreased due to treatment with clotting factor. Nowadays patients are enabled to live a rather normal life, resulting in more (sports) trauma-induced arthropathy in isolated joints like the ankle. As surgical treatment options, fusion of the tibiotalar joint and total ankle replacement are available. Both standard treatments have complications and therefore an alternative treatment is desired. In this study, treatment of haemophilic ankle arthropathy with joint distraction was explored. Three patients with haemophilic ankle arthropathy were treated with joint distraction using an Ilizarov external fixator. Clinical outcomes like function, participation and pain were evaluated in retrospect with three different questionnaires: haemophilia activities list, impact on participation and autonomy and the Van Valburg questionnaire. Structural changes were assessed blinded on X-ray by the Pettersson score and ankle images digital analysis (AIDA) and by an MRI score. All three patients were very satisfied with the clinical outcome of the procedure. They reported a clear improvement for self-perceived functional health, participation in society and autonomy and pain. Partial ankle joint mobility was preserved in the three patients. The Pettersson score remained the same in one patient and slightly improved in the two other patients, while joint space width measured by AIDA and the MRI score demonstrated improvement for all three patients after ankle distraction. This study suggests that joint distraction is a promising treatment for individual cases of haemophilic ankle arthropathy, without additional risk of bleedings during treatment. © 2012 Blackwell Publishing Ltd.

  7. Apollo-Soyuz US-USSR joint mission results

    NASA Technical Reports Server (NTRS)

    Bean, A. L.; Evans, R. E.

    1975-01-01

    The technical and nontechnical objectives of the Apollo-Soyuz mission are briefly considered. The mission demonstrated that Americans and Russians can work together to perform a very complex operation, including rendezvous in space, docking, and the conduction of joint experiments. Certain difficulties which had to be overcome were partly related to differences concerning the role of the astronaut in the basic alignment and docking procedures for space vehicles. Attention is also given to the experiments conducted during the mission and the approach used to overcome the language barrier.

  8. Control of joint motion simulators for biomechanical research

    NASA Technical Reports Server (NTRS)

    Colbaugh, R.; Glass, K.

    1992-01-01

    The authors present a hierarchical adaptive algorithm for controlling upper extremity human joint motion simulators. A joint motion simulator is a computer-controlled, electromechanical system which permits the application of forces to the tendons of a human cadaver specimen in such a way that the cadaver joint under study achieves a desired motion in a physiologic manner. The proposed control scheme does not require knowledge of the cadaver specimen dynamic model, and solves on-line the indeterminate problem which arises because human joints typically possess more actuators than degrees of freedom. Computer simulation results are given for an elbow/forearm system and wrist/hand system under hierarchical control. The results demonstrate that any desired normal joint motion can be accurately tracked with the proposed algorithm. These simulation results indicate that the controller resolved the indeterminate problem redundancy in a physiologic manner, and show that the control scheme was robust to parameter uncertainty and to sensor noise.

  9. Longitudinal joint treatment.

    DOT National Transportation Integrated Search

    2006-03-01

    Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...

  10. Design of a telerobotic controller with joint torque sensors

    NASA Technical Reports Server (NTRS)

    Jansen, J. F.; Herndon, J. N.

    1990-01-01

    The purpose was to analytically show how to design a joint controller for a telerobotic system when joint torque sensors are available. Other sensors such as actuator position, actuator velocity, joint position, and joint velocity are assumed to be accessible; however, the results will also be useful when only partial measurements are available. The controller presented can be applied to either mode of operation of a manipulator (i.e., teleoperation or robotic). Mechanical manipulators with high levels of friction are assumed. The results are applied to a telerobotic system built for NASA. Very high levels of friction have been reduced using high-gain feedback while avoiding limit cycles.

  11. Incudomalleal joint formation: the roles of apoptosis, migration and downregulation

    PubMed Central

    Amin, Susan; Matalova, Eva; Simpson, Carol; Yoshida, Hiroki; Tucker, Abigail S

    2007-01-01

    Background The middle ear of mammals is composed of three endochondrial ossicles, the stapes, incus and malleus. Joints link the malleus to the incus and the incus to the stapes. In the mouse the first arch derived malleus and incus are formed from a single Sox9 and Type II collagen expressing condensation that later subdivides to give rise to two separate ossicles. In contrast the stapes forms from a separate condensation derived from the second branchial arch. Fusion of the malleus and incus is observed in a number of human syndromes and results in conductive hearing loss. Understanding how this joint forms during normal development is thus an important step in furthering our understanding of such defects. Results We show that the developing incudomalleal joint is characterised by a lack of proliferation and discrete areas of apoptosis. Apoptosis has been suggested to aid in the removal of pre-cartilaginous cells from the joint region, allowing for the physical separation of the cartilaginous elements, however, we show that joint initiation is unaffected by blocking apoptosis. There is also no evidence of cell migration out of the presumptive joint region, as observed by labelling of joint and ossicle cells in culture. Using Type II collagen lacZ reporter mice, however, it is evident that cells in the presumptive joint region remain in place and downregulate cartilage markers. Conclusion The malleus and incus first appear as a single united condensation expressing early cartilage markers. The incudomalleal joint region forms by cells in the presumptive joint region switching off cartilage markers and turning on joint markers. Failure in this process may result in fusion of this joint, as observed in human syndromes such as Branchio-Oto-Renal Syndrome or Treacher Collins Syndrome. PMID:18053235

  12. [Viscosity determination of synovial fluids from the canine hip and elbow joint as well as the human knee joint].

    PubMed

    Helms, Gabriele; Rittmann, Pia; Wefstaedt, Patrick; Windhagen, Henning; Pressel, Thomas; Behrens, Bernd-Arno; Nolte, Ingo

    2008-01-01

    The development of pathological changes in both human and canine hip joints is mainly caused by a lack of synovial fluid lubrication. This results in an increased joint abrasion. Even after implantation of joint prosthesis, inadequate lubrication can lead to abrasion in the tribological pair. This can finally result in aseptic loosening of the prosthesis. In spite of the enormous number of studies that have been performed on human, only little knowledge about the tribological properties of the joints in dogs is available in the literature. For this reason the viscosities of synovial fluid, derived from physiological and pathologically changed canine elbow joints were measured. The viscosities were determined by the use of a cone-plate viscometer at different temperatures and shear rates. The obtained values were compared with the viscosity values of pathologically changed synovial fluids from human knee joints as well as with pathological samples from the canine hip joint. The results show that the viscosity values vary within a series of measurements and are inversely proportional to the temperature of the sample and the shear rate. The differences between the average viscosities of canine and human synovial fluids taken from pathologically changed joints are below 4% (22.5 s(-1) at theta1 = 25 degrees C). The findings of this study are being implemented in a FE-Model for the computation of actual forces in the hip joint during different movements. This would represent a contribution to an improved prosthetic treatment of canine and human hips.

  13. Computer simulation of solder joint failure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burchett, S.N.; Frear, D.R.; Rashid, M.M.

    The thermomechanical fatigue failure of solder joints is increasingly becoming an important reliability issue for electronic packages. The purpose of this Laboratory Directed Research and Development (LDRD) project was to develop computational tools for simulating the behavior of solder joints under strain and temperature cycling, taking into account the microstructural heterogeneities that exist in as-solidified near eutectic Sn-Pb joints, as well as subsequent microstructural evolution. The authors present two computational constitutive models, a two-phase model and a single-phase model, that were developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions. Unique metallurgical tests provide themore » fundamental input for the constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations with this model agree qualitatively with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. The single-phase model was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. Special thermomechanical fatigue tests were developed to give fundamental materials input to the models, and an in situ SEM thermomechanical fatigue test system was developed to characterize microstructural evolution and the mechanical behavior of solder joints during the test. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests. The simulation results from the two-phase model showed good fit to the experimental test results.« less

  14. Preliminary results on the fracture analysis of multi-site cracking of lap joints in aircraft skins

    NASA Astrophysics Data System (ADS)

    Beuth, J. L., Jr.; Hutchinson, John W.

    1992-07-01

    Results of a fracture mechanics analysis relevant to fatigue crack growth at rivets in lap joints of aircraft skins are presented. Multi-site damage (MSD) is receiving increased attention within the context of problems of aging aircraft. Fracture analyses previously carried out include small-scale modeling of rivet/skin interactions, larger-scale two-dimensional models of lap joints similar to that developed here, and full scale three-dimensional models of large portions of the aircraft fuselage. Fatigue testing efforts have included flat coupon specimens, two-dimensional lap joint tests, and full scale tests on specimens designed to closely duplicate aircraft sections. Most of this work is documented in the proceedings of previous symposia on the aging aircraft problem. The effect MSD has on the ability of skin stiffeners to arrest the growth of long skin cracks is a particularly important topic that remains to be addressed. One of the most striking features of MSD observed in joints of some test sections and in the joints of some of the older aircraft fuselages is the relative uniformity of the fatigue cracks from rivet to rivet along an extended row of rivets. This regularity suggests that nucleation of the cracks must not be overly difficult. Moreover, it indicates that there is some mechanism which keeps longer cracks from running away from shorter ones, or, equivalently, a mechanism for shorter cracks to catch-up with longer cracks. This basic mechanism has not been identified, and one of the objectives of the work is to see to what extent the mechanism is revealed by a fracture analysis of the MSD cracks. Another related aim is to present accurate stress intensity factor variations with crack length which can be used to estimate fatigue crack growth lifetimes once cracks have been initiated. Results are presented which illustrate the influence of load shedding from rivets with long cracks to neighboring rivets with shorter cracks. Results are also included

  15. Preliminary results on the fracture analysis of multi-site cracking of lap joints in aircraft skins

    NASA Technical Reports Server (NTRS)

    Beuth, J. L., Jr.; Hutchinson, John W.

    1992-01-01

    Results of a fracture mechanics analysis relevant to fatigue crack growth at rivets in lap joints of aircraft skins are presented. Multi-site damage (MSD) is receiving increased attention within the context of problems of aging aircraft. Fracture analyses previously carried out include small-scale modeling of rivet/skin interactions, larger-scale two-dimensional models of lap joints similar to that developed here, and full scale three-dimensional models of large portions of the aircraft fuselage. Fatigue testing efforts have included flat coupon specimens, two-dimensional lap joint tests, and full scale tests on specimens designed to closely duplicate aircraft sections. Most of this work is documented in the proceedings of previous symposia on the aging aircraft problem. The effect MSD has on the ability of skin stiffeners to arrest the growth of long skin cracks is a particularly important topic that remains to be addressed. One of the most striking features of MSD observed in joints of some test sections and in the joints of some of the older aircraft fuselages is the relative uniformity of the fatigue cracks from rivet to rivet along an extended row of rivets. This regularity suggests that nucleation of the cracks must not be overly difficult. Moreover, it indicates that there is some mechanism which keeps longer cracks from running away from shorter ones, or, equivalently, a mechanism for shorter cracks to catch-up with longer cracks. This basic mechanism has not been identified, and one of the objectives of the work is to see to what extent the mechanism is revealed by a fracture analysis of the MSD cracks. Another related aim is to present accurate stress intensity factor variations with crack length which can be used to estimate fatigue crack growth lifetimes once cracks have been initiated. Results are presented which illustrate the influence of load shedding from rivets with long cracks to neighboring rivets with shorter cracks. Results are also included

  16. Joint torques in a freely walking insect reveal distinct functions of leg joints in propulsion and posture control

    PubMed Central

    2016-01-01

    Determining the mechanical output of limb joints is critical for understanding the control of complex motor behaviours such as walking. In the case of insect walking, the neural infrastructure for single-joint control is well described. However, a detailed description of the motor output in form of time-varying joint torques is lacking. Here, we determine joint torques in the stick insect to identify leg joint function in the control of body height and propulsion. Torques were determined by measuring whole-body kinematics and ground reaction forces in freely walking animals. We demonstrate that despite strong differences in morphology and posture, stick insects show a functional division of joints similar to other insect model systems. Propulsion was generated by strong depression torques about the coxa–trochanter joint, not by retraction or flexion/extension torques. Torques about the respective thorax–coxa and femur–tibia joints were often directed opposite to fore–aft forces and joint movements. This suggests a posture-dependent mechanism that counteracts collapse of the leg under body load and directs the resultant force vector such that strong depression torques can control both body height and propulsion. Our findings parallel propulsive mechanisms described in other walking, jumping and flying insects, and challenge current control models of insect walking. PMID:26791608

  17. Tensile strength of simulated and welded butt joints in W-Cu composite sheet

    NASA Technical Reports Server (NTRS)

    Moore, Thomas J.; Watson, Gordon K.

    1994-01-01

    The weldability of W-Cu composite sheet was investigated using simulated and welded joints. The welded joints were produced in a vacuum hot press. Tensile test results showed that simulated joints can provide strength and failure mode data which can be used in joint design for actual weldments. Although all of the welded joints had flaws, a number of these joints were as strong as the W-Cu composite base material.

  18. Joint research effort on vibrations of twisted plates, phase 1: Final results

    NASA Technical Reports Server (NTRS)

    Kielb, R. E.; Leissa, A. W.; Macbain, J. C.; Carney, K. S.

    1985-01-01

    The complete theoretical and experimental results of the first phase of a joint government/industry/university research study on the vibration characteristics of twisted cantilever plates are given. The study is conducted to generate an experimental data base and to compare many different theoretical methods with each other and with the experimental results. Plates with aspect ratios, thickness ratios, and twist angles representative of current gas turbine engine blading are investigated. The theoretical results are generated by numerous finite element, shell, and beam analysis methods. The experimental results are obtained by precision matching a set of twisted plates and testing them at two laboratories. The second and final phase of the study will concern the effects of rotation.

  19. Multi-Country Experience in Delivering a Joint Course on Software Engineering--Numerical Results

    ERIC Educational Resources Information Center

    Budimac, Zoran; Putnik, Zoran; Ivanovic, Mirjana; Bothe, Klaus; Zdravkova, Katerina; Jakimovski, Boro

    2014-01-01

    A joint course, created as a result of a project under the auspices of the "Stability Pact of South-Eastern Europe" and DAAD, has been conducted in several Balkan countries: in Novi Sad, Serbia, for the last six years in several different forms, in Skopje, FYR of Macedonia, for two years, for several types of students, and in Tirana,…

  20. COBRA ATD minefield detection results for the Joint Countermine ACTD Demonstrations

    NASA Astrophysics Data System (ADS)

    Stetson, Suzanne P.; Witherspoon, Ned H.; Holloway, John H., Jr.; Suiter, Harold R.; Crosby, Frank J.; Hilton, Russell J.; McCarley, Karen A.

    2000-08-01

    The Coastal Battlefield Reconnaissance and Analysis)COBRA) system described here was a Marine Corps Advanced Technology Demonstration (ATD) development consisting of an unmanned aerial vehicle (UAV) airborne multispectral video sensor system and ground station which processes the multispectral video data to automatically detect minefields along the flight path. After successful completion of the ATD, the residual COBRA ATD system participated in the Joint Countermine (JCM) Advanced Concept Technology Demonstration (ACTD) Demo I held at Camp Lejeune, North Carolina in conjunction with JTFX97 and Demo II held in Stephenville, Newfoundland in conjunction with MARCOT98. These exercises demonstrated the COBRA ATD system in an operational environment, detecting minefields that included several different mine types in widely varying backgrounds. The COBRA system performed superbly during these demonstrations, detecting mines under water, in the surf zone, on the beach, and inland, and has transitioned to an acquisition program. This paper describes the COBRA operation and performance results for these demonstrations, which represent the first demonstrated capability for remote tactical minefield detection from a UAV. The successful COBRA technologies and techniques demonstrated for tactical UAV minefield detection in the Joint Countermine Advanced Concept Technology Demonstrations have formed the technical foundation for future developments in Marine Corps, Navy, and Army tactical remote airborne mine detection systems.

  1. Design and Performance Analysis of a new Rotary Hydraulic Joint

    NASA Astrophysics Data System (ADS)

    Feng, Yong; Yang, Junhong; Shang, Jianzhong; Wang, Zhuo; Fang, Delei

    2017-07-01

    To improve the driving torque of the robots joint, a wobble plate hydraulic joint is proposed, and the structure and working principle are described. Then mathematical models of kinematics and dynamics was established. On the basis of this, dynamic simulation and characteristic analysis are carried out. Results show that the motion curve of the joint is continuous and the impact is small. Moreover the output torque of the joint characterized by simple structure and easy processing is large and can be rotated continuously.

  2. Evaluation of pipe-type cable joint restraint systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silver, D.A.; Seman, G.W.

    1990-03-01

    the purpose of this project was to evaluate two systems for restraining the movement of 345kV high-pressure oil-filled (HPOF) cable joints during load cycling. Problems with joints and adjacent cables due to thermomechanical bending (TMB) experienced by the Consolidated Edison Company of New York and Public Service Electric Gas Company of New Jersey are reviewed. Some approaches to reducing or preventing TMB induced damage to HPOF pipe type cable joints are discussed. The design and operation of a special test apparatus for simulating TMB effects under laboratory conditions is described. One of the two joint restraint systems evaluated under thismore » project was developed by PSE G and employed wedging devices, which could be retrofitted into existing installations, that limited the longitudinal movement of the joints during load cycling. The other system developed by Pirelli Cable Corporation applied the restraining force to the cylindrical portion of the hand applied joint insulation by means of support spiders and steel rods attached to the reducer faces. The test results show that the PSE G restraint system can effectively limit joint longitudinal movement while causing a minimal amount of mechanical disturbance to the joint stress cones. The test results obtained with the PCC system are inconclusive and indicate that further refinement and testing are required to demonstrate the effectiveness of this promising joint restraint system.« less

  3. Generalized Models for Rock Joint Surface Shapes

    PubMed Central

    Du, Shigui; Hu, Yunjin; Hu, Xiaofei

    2014-01-01

    Generalized models of joint surface shapes are the foundation for mechanism studies on the mechanical effects of rock joint surface shapes. Based on extensive field investigations of rock joint surface shapes, generalized models for three level shapes named macroscopic outline, surface undulating shape, and microcosmic roughness were established through statistical analyses of 20,078 rock joint surface profiles. The relative amplitude of profile curves was used as a borderline for the division of different level shapes. The study results show that the macroscopic outline has three basic features such as planar, arc-shaped, and stepped; the surface undulating shape has three basic features such as planar, undulating, and stepped; and the microcosmic roughness has two basic features such as smooth and rough. PMID:25152901

  4. [Endoprosthesis of the ankle joint. Indications and long-term results].

    PubMed

    Endrich, B; Terbrüggen, D

    1991-10-01

    The treatment of a post-traumatic, progressively more painful ankle joint causes increasing disablement. It might require alternatives to conventional surgery if a patient does not consent to ankle arthrodesis to alleviate the pain. Therefore, we report on a retrospective study of 10 patients (age 25-73 years at the time of surgery). All of them refused arthrodesis; thus 10 total ankle arthroplasties were performed between 1982 and 1989. 5 women and 5 men were treated who have been suffering from severe post-traumatic arthrosis for 3-46 years. Since performance of a single-axis arthroplasty (ICLH prosthesis) in each patient, the mean follow-up has been 4.6 years. One year after surgery, the results could be considered good or excellent in 9 of the 10 patients; only 1 person experienced local wound infection, which led to removal of the implant 4 months later and ultimately to arthrodesis. Two years later, 7 patients are eligible for follow-up because 1 underwent surgery in February 1989. Another patient experienced aseptic loosening after 18 months; he was admitted to our hospital for arthrodesis. Three years after endoprosthetic surgery, all except 1 woman with occasional pain and stiffness were found to have satisfactory results on follow-up. The relief of pain was gratifying in all patients, with ankle function well maintained (at least 0-0-30 degrees). At present, the prosthesis is still functional in 6 patients (surgery 1.5-8 years ago). They can go about their usual daily business without apparent pain and with appropriate function; 2 of them, however, show radiolucent lines on standard X-rays of the ankle, suggesting some loosening.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Estimating anatomical wrist joint motion with a robotic exoskeleton.

    PubMed

    Rose, Chad G; Kann, Claudia K; Deshpande, Ashish D; O'Malley, Marcia K

    2017-07-01

    Robotic exoskeletons can provide the high intensity, long duration targeted therapeutic interventions required for regaining motor function lost as a result of neurological injury. Quantitative measurements by exoskeletons have been proposed as measures of rehabilitative outcomes. Exoskeletons, in contrast to end effector designs, have the potential to provide a direct mapping between human and robot joints. This mapping rests on the assumption that anatomical axes and robot axes are aligned well, and that movement within the exoskeleton is negligible. These assumptions hold well for simple one degree-of-freedom joints, but may not be valid for multi-articular joints with unique musculoskeletal properties such as the wrist. This paper presents an experiment comparing robot joint kinematic measurements from an exoskeleton to anatomical joint angles measured with a motion capture system. Joint-space position measurements and task-space smoothness metrics were compared between the two measurement modalities. The experimental results quantify the error between joint-level position measurements, and show that exoskeleton kinematic measurements preserve smoothness characteristics found in anatomical measures of wrist movements.

  6. Preliminary results on the development of vacuum brazed joints for cryogenic wind tunnel aerofoil models

    NASA Technical Reports Server (NTRS)

    Wigley, D. A.; Sandefur, P. G., Jr.; Lawing, P. L.

    1981-01-01

    The results of initial experiments show that high-strength void-free bonds can be formed by vacuum brazing of stainless steels using copper and nickel-based filler metals. In Nitronic 40, brazed joints have been formed with strengths in excess of the yield strength of the parent metal, and even at liquid nitrogen temperatures the excellent mechanical properties of the parent metal are only slightly degraded. The poor toughness of 15-5 P.H. stainless steel at cryogenic temperatures is lowered even further by the presence of the brazed bonds investigated. It is highly unlikely that the technique would be used for any critical areas of aerofoil models intended for low-temperature service. Nevertheless, the potential advantages of this simplified method of construction still have attractions for use at ambient temperatures.

  7. Estimation of joint stiffness with a compliant load.

    PubMed

    Ludvig, Daniel; Kearney, Robert E

    2009-01-01

    Joint stiffness defines the dynamic relationship between the position of the joint and the torque acting about it. It consists of two components: intrinsic and reflex stiffness. Many previous studies have investigated joint stiffness in an open-loop environment, because the current algorithm in use is an open-loop algorithm. This paper explores issues related to the estimation of joint stiffness when subjects interact with compliant loads. First, we show analytically how the bias in closed-loop estimates of joint stiffness depends on the properties of the load, the noise power, and length of the estimated impulse response functions (IRF). We then demonstrate with simulations that the open-loop analysis will fail completely for an elastic load but may succeed for an inertial load. We further show that the open-loop analysis can yield unbiased results with an inertial load and document IRF length, signal-to-noise ratio needed, and minimum inertia needed for the analysis to succeed. Thus, by using a load with a properly selected inertia, open-loop analysis can be used under closed-loop conditions.

  8. Influence of Joint Flexibility on Vibration Analysis of Free-Free Beams

    NASA Astrophysics Data System (ADS)

    Gunda, Jagadish Babu; Krishna, Y.

    2014-12-01

    In present work, joint flexibility (or looseness) of the free-free beam is investigated by using a two noded beam finite element formulation with transverse displacement and joint rotations as the degrees of freedom per node at joint location. Flexibility of the joint is primarily represented by means of a rotational spring analogy, where the stiffness of the rotational spring characterizes the looseness of the flexible joint for an applied bending moment. Influence of joint location as well as joint stiffness on modal behavior of first five modes of slender, uniform free-free beams are discussed for various values of non-dimensional rotational spring stiffness parameter. Numerical accuracy of the results obtained from the present finite element formulation are validated by using the commercially available finite element software which shows the confidence gained on the numerical results discussed in the present study.

  9. Screening Adhesively Bonded Single-Lap-Joint Testing Results Using Nonlinear Calculation Parameters

    DTIC Science & Technology

    2012-03-01

    versus displacement response for single-lap-joints bonded with damage-tolerant adhe- sives, such the polyurea adhesive plotted in Figure 2, is much...displacement response for a single-lap-joint bonded with a polyurea adhesive. Complex x-y plots are commonly fitted using the Levenberg-Marquardt...expected decrease in maximum strength for the polyurea in compar- ison to the epoxy, which could have been obtained using a traditional analysis approach

  10. Discrete and continuous joint coupling relationships in uninjured recreational runners.

    PubMed

    Dierks, Tracy A; Davis, Irene

    2007-06-01

    Abnormal joint coupling is thought to be related to overuse injuries in runners. However, researchers do not yet know what constitutes normal joint coupling during running, which makes abnormal coupling difficult to define. Lower extremity kinematics were collected from 40 recreational runners during stance. Joint coupling methods were applied and, for each method, means and both within- and between-subject variability were calculated. The 95% confidence interval was used to compare differences across coupling relationships and periods of stance. Timing between rearfoot eversion, tibial internal rotation, and knee flexion were relatively synchronous while relationships involving knee internal rotation were more asynchronous. The excursion ratios showed that every 2 degrees of rearfoot eversion was coupled with 1 degrees of both tibial internal rotation and knee internal rotation. Vector coding results showed that just beyond maximum loading, all joint coupling relationships resulted in relatively equal amounts of motion, while the within-subject variability was similar throughout stance. The continuous relative phase results showed that the most out-of-phase coupling occurred in the periods around heel-strike and toe-off while the most in-phase coupling occurred in the period just beyond maximum loading of the leg. The continuous relative phase within-subject variability was greatest at the periods around heel-strike and toe-off and smallest just beyond maximum loading. With a better understanding of joint coupling in uninjured runners, these data will help to serve as a reference for future studies investigating the relationship between running injuries and abnormal joint coupling.

  11. Nikolaus Rüdinger (1832-1896), His Description of Joint Innervation in 1857, and the History of Surgical Joint Denervation.

    PubMed

    Gohritz, Andreas; Kaiser, Erich; Guggenheim, Merlin; Dellon, Arnold Lee

    2018-01-01

     Selective joint denervation has become a reliable palliative treatment, especially for painful joints in the upper and lower extremity.  This article highlights the life and work of Nikolaus Rüdinger (1832-1896) who first described joint innervation which became the basis of later techniques of surgical joint denervation. The historical evolution of this method is outlined.  Rüdinger made a unique career from apprentice barber to military surgeon and anatomy professor in Munich, Germany. His first description of articular innervation of temporomandibular, shoulder, elbow, wrist, finger, sacroiliac, hip, knee, ankle, foot, and toe joints in 1857 stimulated the subsequent history of surgical joint denervation. Comparing his investigations with modern joint denervation methods, developed by pioneers like Albrecht Wilhelm or A. Lee Dellon, shows his great exactitude and anatomical correspondence despite different current terminology. Clinical series of modern surgical joint denervations reveal success rates of up to 80% with reliable long-term results.  The history of joint denervation with Rüdinger as its important protagonist offers inspiring insights into the evolution of surgical techniques and exemplifies the value of descriptive functional anatomy, even if surgical application may not have been realized until a century later. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.

    2010-01-01

    Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.

  13. [Tossy III injuries of the acromioclavicular joint. In what circumstances is surgery still justified? Personal results and literature review].

    PubMed

    Prokop, A; Helling, H J; Andermahr, J; Mönig, S; Rehm, K E

    2003-05-01

    In Germany AC-joint-dislocations type Tossy III are treated in most of the cases operatively. Over two times of period we treated AC-joint-dislocations type Tossy III with biodegradable PDS-cords. 54 patients were operated between 1989 and 1997 and followed up after 39 months. 87.5% of patients are satisfied with results and have 10.2 points at Taftscore. In this period we couldn't differentiated the results by Rockwood classification. 12 patients with Rockwood V were operated between 1998 and 2002 and followed up after 14 months. Excellent and good results were seen in 92% of cases. At Taftscore we seen 10.7 points. 3 patients with Rockwood III were treated conservative with 10.3 points and 3 patients were operated with 10.7 points at Taftscore. AC-joint dislocations should be classified to Rockwood. No differences were seen between operation and conservative treatment in Rockwood III in literature. We recommend operation with PDS cords with good results in Rockwood V.

  14. MR imaging of the metacarpophalangeal joints of the fingers: evaluation of 38 patients with chronic joint disability.

    PubMed

    Theumann, Nicolas H; Pessis, Eric; Lecompte, Martin; Le Viet, Dominique; Valenti, Philippe; Chevrot, Alain; Bittoun, Jacques; Schnyder, Pierre; Resnick, Donald; Drapé, Jean-Luc

    2005-04-01

    To report the MR imaging findings of painful injured metacarpophalangeal (MCP) joints of the fingers. MR imaging of 39 injured MCP joints in 38 patients was performed after a mean delay of 8.8 months. The MR images were obtained with the fingers in extended and flexed positions using T2-weighted and T1-weighted sequences before and after intravenous injection of a gadolinium compound. Ten patients were treated surgically. Mean clinical follow-up was 1.8 years. Tears of the collateral ligaments were the most common lesion (30/39), most being radial in location. Contrast-enhanced axial T1-weighted images with the MCP joint in a flexed position showed these lesions optimally. Ten tears were partial and 20 were complete. In 13 patients, MR images showed 17 associated lesions including injuries of the extensor hood (10/17), interosseous tendon (3/17), palmar plate (3/17), and an osteochondral lesion (1/17). Sagittal MR images were essential to highlight palmar plate tears. Partial or complete tears of the collateral ligaments are prevalent MR imaging findings in patients with chronic disability resulting from injuries to the MCP joints. Although conservative treatment generally is sufficient for isolated injuries of the collateral ligaments, surgical repair is often required in cases of more extensive injuries. MR imaging may clearly delineate associated lesions of and about the MCP joints.

  15. Radiographic progression in weight-bearing joints of patients with rheumatoid arthritis after TNF-blocking therapies.

    PubMed

    Seki, Eiko; Matsushita, Isao; Sugiyama, Eiji; Taki, Hirohumi; Shinoda, Koichiro; Hounoki, Hiroyuki; Motomura, Hiraku; Kimura, Tomoatsu

    2009-04-01

    The aim of the present study was to assess the influence of tumor necrosis factor (TNF)-blocking therapies on weight-bearing joints in patients with rheumatoid arthritis. Changes in clinical variables and radiological findings in 213 weight-bearing joints (69 hip joints, 63 knee joints, and 81 ankle joints) of 42 consecutive patients were investigated at baseline and at 1 year of TNF-blocking therapies. Structural damage to the weight-bearing joints was assessed using the Larsen scoring method. Detailed comparisons of the sizes and locations of erosions were performed for each set of radiographs of the respective joints. Assessment of radiographs of the 213 weight-bearing joints indicated progression of the Larsen grade in eight joints. Another five joints without Larsen grade progression showed apparent radiographic progression of joint damage based on increases in bony erosions. Overall, 13 joints (6%) of eight patients (19%) showed progression of joint damage after 1 year of TNF-blocking therapies. Analysis of each baseline grade indicated that radiographic progression of joint damage was inhibited in most grade 0-II joints. On the other hand, all hip and knee joints with pre-existing damage of grade III/IV showed apparent progression even in patients with good response. The results further suggested that radiographic progression may occur in less damaged joints when the patients were non-responders to the therapy. Among the weight-bearing joints, ankle joints showed different radiographic behavior and four ankle joints displayed improvement of radiographic damage. Early initiation of anti-TNF therapy should be necessary especially when the patients are starting to show early structural damage in weight-bearing joints.

  16. Restoration of horizontal stability in complete acromioclavicular joint separations: surgical technique and preliminary results

    PubMed Central

    2013-01-01

    Background Our purpose was to investigate the clinical efficacy of arthroscope-assisted acromioclavicular ligament reconstruction in combination with double endobutton coracoclavicular ligament reconstruction for the treatment of complete acromioclavicular joint dislocation. Methods During the period from February 2010 to October 2012, ten patients with Rockwood types IV and V acromioclavicular joint dislocation were hospitalized and nine were treated with acromioclavicular ligament reconstruction combined with double endobutton of coracoclavicular ligament reconstruction. The improvement in shoulder functions was assessed using a Constant score and visual analog scale (VAS) system. Results The mean follow-up period was 33.6 ± 5.4 months. The mean Constant scores improved from 25.2 ± 6.6 preoperatively to 92.4 ± 6.5 postoperatively, while the mean VAS score decreased from 5.9 ± 1.4 to 1.2 ± 0.9; significant differences were observed. The final follow-up revealed that excellent outcomes were achieved in eight patients and good outcome in two patients. Conclusion Arthroscope-assisted acromioclavicular ligament reconstruction in combination with double endobutton of coracoclavicular ligament reconstruction is an effective approach for treatment of acute complete acromioclavicular joint dislocation. PMID:24225119

  17. Numerical Model for the Study of the Strength and Failure Modes of Rock Containing Non-Persistent Joints

    NASA Astrophysics Data System (ADS)

    Vergara, Maximiliano R.; Van Sint Jan, Michel; Lorig, Loren

    2016-04-01

    The mechanical behavior of rock containing parallel non-persistent joint sets was studied using a numerical model. The numerical analysis was performed using the discrete element software UDEC. The use of fictitious joints allowed the inclusion of non-persistent joints in the model domain and simulating the progressive failure due to propagation of existing fractures. The material and joint mechanical parameters used in the model were obtained from experimental results. The results of the numerical model showed good agreement with the strength and failure modes observed in the laboratory. The results showed the large anisotropy in the strength resulting from variation of the joint orientation. Lower strength of the specimens was caused by the coalescence of fractures belonging to parallel joint sets. A correlation was found between geometrical parameters of the joint sets and the contribution of the joint sets strength in the global strength of the specimen. The results suggest that for the same dip angle with respect to the principal stresses; the uniaxial strength depends primarily on the joint spacing and the angle between joints tips and less on the length of the rock bridges (persistency). A relation between joint geometrical parameters was found from which the resulting failure mode can be predicted.

  18. Reconstructive surgery for patellofemoral joint incongruency.

    PubMed

    Neumann, M V; Stalder, M; Schuster, A J

    2016-03-01

    A retrospective analysis of a heterogeneous patient cohort was performed to determine the outcome and eligibility of a combined trochleaplasty and soft tissue-balancing technique for repair of patellofemoral joint disorders. A strict surgical treatment algorithm including trochleaplasty and reconstruction of the medial patellofemoral ligament and vastus medialis oblique muscle was implemented to restore the patellofemoral joint. A heterogeneous patient cohort including 46 consecutively treated symptomatic knees was reviewed. The median follow-up period was 4.7 years (range 24-109 months). No patellar redislocation occurred post-operatively, and the median Kujala score improved from 62 (9-96) to 88 (47-100) points (p < 0.001) at follow-up. Radiological signs of trochlear dysplasia were corrected, and both patellar height and trochlear depth were significantly restored after surgery. In total, 16% of affected patients with pre-existing patellofemoral degenerative changes showed progression of osteoarthrosis according to the Kellgren and Lawrence classification. The surgical combination of trochleaplasty and reconstruction of the medial patellofemoral ligament and vastus medialis oblique muscle offers excellent clinical and radiological results. The overall results of the present study showed significant improvement of the Kujala score in patients with Dejour grades C and D dysplasia. These results outline the clinical relevance of trochleaplasty with additional soft tissue balancing as an effective joint-preserving method with satisfying results in patients with pre-existing degenerative changes. IV.

  19. Disclosing the temperature of columnar jointing in lavas.

    PubMed

    Lamur, Anthony; Lavallée, Yan; Iddon, Fiona E; Hornby, Adrian J; Kendrick, Jackie E; von Aulock, Felix W; Wadsworth, Fabian B

    2018-04-12

    Columnar joints form by cracking during cooling-induced contraction of lava, allowing hydrothermal fluid circulation. A lack of direct observations of their formation has led to ambiguity about the temperature window of jointing and its impact on fluid flow. Here we develop a novel thermo-mechanical experiment to disclose the temperature of columnar jointing in lavas. Using basalts from Eyjafjallajökull volcano (Iceland) we show that contraction during cooling induces stress build-up below the solidus temperature (980 °C), resulting in localised macroscopic failure between 890 and 840 °C. This temperature window for incipient columnar jointing is supported by modelling informed by mechanical testing and thermal expansivity measurements. We demonstrate that columnar jointing takes place well within the solid state of volcanic rocks, and is followed by a nonlinear increase in system permeability of <9 orders of magnitude during cooling. Columnar jointing may promote advective cooling in magmatic-hydrothermal environments and fluid loss during geothermal drilling and thermal stimulation.

  20. Generalized Cross Entropy Method for estimating joint distribution from incomplete information

    NASA Astrophysics Data System (ADS)

    Xu, Hai-Yan; Kuo, Shyh-Hao; Li, Guoqi; Legara, Erika Fille T.; Zhao, Daxuan; Monterola, Christopher P.

    2016-07-01

    Obtaining a full joint distribution from individual marginal distributions with incomplete information is a non-trivial task that continues to challenge researchers from various domains including economics, demography, and statistics. In this work, we develop a new methodology referred to as ;Generalized Cross Entropy Method; (GCEM) that is aimed at addressing the issue. The objective function is proposed to be a weighted sum of divergences between joint distributions and various references. We show that the solution of the GCEM is unique and global optimal. Furthermore, we illustrate the applicability and validity of the method by utilizing it to recover the joint distribution of a household profile of a given administrative region. In particular, we estimate the joint distribution of the household size, household dwelling type, and household home ownership in Singapore. Results show a high-accuracy estimation of the full joint distribution of the household profile under study. Finally, the impact of constraints and weight on the estimation of joint distribution is explored.

  1. Impact extractive fracture of jointed steel plates of a bolted joint

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.

    2012-08-01

    This study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of a bolted joint used in a car body. For the accurate prediction of crash characteristics of car bodies by computer-aided engineering (CAE), it is also necessary to examine the behavior and fracture of jointed steel plates subjected to impact loads. Although the actual impact fracture of jointed steel plates of a bolted joint used in cars is complicated, for simplifying the problem it might be classified into the shear fracture and the extractive fracture of jointed steel plates. Attention is given to the extractive fracture of jointed steel plates in this study. The extractive behavior and fracture of three kinds of steel plates used for cars are examined in experiments and numerical simulations. The impact extraction test of steel plates jointed by a bolt is performed using the one-bar method, together with the static test. In order to understand the mechanism of extractive fracture process of jointed steel plates, numerical simulations by a FEM code LS-DYNA are also carried out. The obtained results suggest that a stress-based fracture criterion may be developed for the impact extractive fracture of jointed steel plates of a bolted joint used in a car body.

  2. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    PubMed

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI

  3. Feature-extracted joint transform correlation.

    PubMed

    Alam, M S

    1995-12-10

    A new technique for real-time optical character recognition that uses a joint transform correlator is proposed. This technique employs feature-extracted patterns for the reference image to detect a wide range of characters in one step. The proposed technique significantly enhances the processing speed when compared with the presently available joint transform correlator architectures and shows feasibility for multichannel joint transform correlation.

  4. ULNAR NERVE COMPONENT TO INNERVATION OF THUMB CARPOMETACARPAL JOINT

    PubMed Central

    Miki, Roberto Augusto; Kam, Check C; Gennis, Elisabeth R; Barkin, Jodie A; Riel, Ryan U; Robinson, Philip G; Owens, Patrick W

    2011-01-01

    Purpose Thumb carpometacarpal (CMC) joint arthritis is one of the most common problems addressed by hand surgeons. The gold standard of treatment for thumb CMC joint arthritis is trapeziectomy, ligament reconstruction and tendon interposition. Denervation of the thumb CMC joint is not currently used to treat arthritis in this joint due to the failure of the procedure to yield significant symptomatic relief. The failure of denervation is puzzling, given that past anatomic studies show the radial nerve is the major innervation of the thumb CMC joint with the lateral antebrachial nerve and the median nerve also innervating this joint. Although no anatomic study has ever shown that the ulnar nerve innervates the CMC joint, due to both the failure of denervation and the success of arthroscopic thermal ablation, we suspect that previous anatomic studies may have overlooked innervation of the thumb CMC joint via the ulnar nerve. Methods We dissected 19 formalin-preserved cadaveric hand-to-mid-forearm specimens. The radial, median and ulnar nerves were identified in the proximal forearm and then followed distally. Any branch heading toward the radial side of the hand were followed to see if they innervated the thumb CMC joint. Results Eleven specimens (58%) had superficial radial nerve innervation to the thumb CMC joint. Nine specimens (47%) had median nerve innervation from the motor branch. Nine specimens (47%) had ulnar nerve innervation from the motor branch. Conclusions We believe this is the first study to demonstrate that the ulnar nerve innervates the thumb CMC joint This finding may explain the poor results seen in earlier attempts at denervation of the thumb CMC, but the more favorable results with techniques such as arthroscopy with thermal ablation. PMID:22096446

  5. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    PubMed Central

    Avgoulas, Evangelos I.; Sutcliffe, Michael P. F.

    2016-01-01

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints. PMID:28773688

  6. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints.

    PubMed

    Avgoulas, Evangelos I; Sutcliffe, Michael P F

    2016-07-12

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  7. The Joint Physics Analysis Center: Recent results

    NASA Astrophysics Data System (ADS)

    Fernández-Ramírez, César

    2016-10-01

    We review some of the recent achievements of the Joint Physics Analysis Center, a theoretical collaboration with ties to experimental collaborations, that aims to provide amplitudes suitable for the analysis of the current and forthcoming experimental data on hadron physics. Since its foundation in 2013, the group is focused on hadron spectroscopy in preparation for the forthcoming high statistics and high precision experimental data from BELLEII, BESIII, CLAS12, COMPASS, GlueX, LHCb and (hopefully) PANDA collaborations. So far, we have developed amplitudes for πN scattering, KN scattering, pion and J/ψ photoproduction, two kaon photoproduction and three-body decays of light mesons (η, ω, ϕ). The codes for the amplitudes are available to download from the group web page and can be straightforwardly incorporated to the analysis of the experimental data.

  8. Strength Variation of Parachute Joints

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    A parachute joint is defined as a location where a component is sewn or connected to another component. During the design and developmental phase of a parachute system, the joints for each structural component are isolated and tested through a process called seam and joint testing. The objective of seam and joint testing is to determine the degradation on a single component due to interaction with other components; this data is then used when calculating the margin of safety for that component. During the engineering developmental phase of CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module, testing was completed for every joint of the six subsystems: the four parachutes (main, drogue, pilot, and FBCP [forward bay cover parachute]), the retention release bridle, and the retention panels. The number of joint tests for these subsystems totaled 92, which provides a plethora of data and results for further analysis. In this paper, the data and results of these seam and joint tests are examined to determine the effects, if any, of different operators and sewing machines on the strength of parachute joints. Other variables are also studied to determine their effect on joint strength, such as joint complexity, joint strength magnitude, material type, and material construction. Findings reveal that an optimally-run seam and joint test program could result in an increased understanding of the structure of the parachute; this should lead to a parachute built with optimal components, potentially saving system weight and volume.

  9. Experimental Studies on the Mechanical Behaviour of Rock Joints with Various Openings

    NASA Astrophysics Data System (ADS)

    Li, Y.; Oh, J.; Mitra, R.; Hebblewhite, B.

    2016-03-01

    The mechanical behaviour of rough joints is markedly affected by the degree of joint opening. A systematic experimental study was conducted to investigate the effect of the initial opening on both normal and shear deformations of rock joints. Two types of joints with triangular asperities were produced in the laboratory and subjected to compression tests and direct shear tests with different initial opening values. The results showed that opened rock joints allow much greater normal closure and result in much lower normal stiffness. A semi-logarithmic law incorporating the degree of interlocking is proposed to describe the normal deformation of opened rock joints. The proposed equation agrees well with the experimental results. Additionally, the results of direct shear tests demonstrated that shear strength and dilation are reduced because of reduced involvement of and increased damage to asperities in the process of shearing. The results indicate that constitutive models of rock joints that consider the true asperity contact area can be used to predict shear resistance along opened rock joints. Because rock masses are loosened and rock joints become open after excavation, the model suggested in this study can be incorporated into numerical procedures such as finite-element or discrete-element methods. Use of the model could then increase the accuracy and reliability of stability predictions for rock masses under excavation.

  10. A joint equalization algorithm in high speed communication systems

    NASA Astrophysics Data System (ADS)

    Hao, Xin; Lin, Changxing; Wang, Zhaohui; Cheng, Binbin; Deng, Xianjin

    2018-02-01

    This paper presents a joint equalization algorithm in high speed communication systems. This algorithm takes the advantages of traditional equalization algorithms to use pre-equalization and post-equalization. The pre-equalization algorithm takes the advantage of CMA algorithm, which is not sensitive to the frequency offset. Pre-equalization is located before the carrier recovery loop in order to make the carrier recovery loop a better performance and overcome most of the frequency offset. The post-equalization takes the advantage of MMA algorithm in order to overcome the residual frequency offset. This paper analyzes the advantages and disadvantages of several equalization algorithms in the first place, and then simulates the proposed joint equalization algorithm in Matlab platform. The simulation results shows the constellation diagrams and the bit error rate curve, both these results show that the proposed joint equalization algorithm is better than the traditional algorithms. The residual frequency offset is shown directly in the constellation diagrams. When SNR is 14dB, the bit error rate of the simulated system with the proposed joint equalization algorithm is 103 times better than CMA algorithm, 77 times better than MMA equalization, and 9 times better than CMA-MMA equalization.

  11. Designs and performance of three new microprocessor-controlled knee joints.

    PubMed

    Thiele, Julius; Schöllig, Christina; Bellmann, Malte; Kraft, Marc

    2018-02-09

    A crossover design study with a small group of subjects was used to evaluate the performance of three microprocessor-controlled exoprosthetic knee joints (MPKs): C-Leg 4, Plié 3 and Rheo Knee 3. Given that the mechanical designs and control algorithms of the joints determine the user outcome, the influence of these inherent differences on the functional characteristics was investigated in this study. The knee joints were evaluated during level-ground walking at different velocities in a motion analysis laboratory. Additionally, technical analyses using patents, technical documentations and X-ray computed tomography (CT) for each knee joint were performed. The technical analyses showed that only C-Leg 4 and Rheo Knee 3 allow microprocessor-controlled adaptation of the joint resistances for different gait velocities. Furthermore, Plié 3 is not able to provide stance extension damping. The biomechanical results showed that only if a knee joint adapts flexion and extension resistances by the microprocessor all known advantages of MPKs can become apparent. But not all users may benefit from the examined functions: e.g. a good accommodation to fast walking speeds or comfortable stance phase flexion. Hence, a detailed comparison of user demands and performance of the designated knee joint is mandatory to ensure a maximum in user outcome.

  12. Mechanical Behavior of CFRP Lattice Core Sandwich Bolted Corner Joints

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaolei; Liu, Yang; Wang, Yana; Lu, Xiaofeng; Zhu, Lingxue

    2017-12-01

    The lattice core sandwich structures have drawn more attention for the integration of load capacity and multifunctional applications. However, the connection of carbon fibers reinforced polymer composite (CFRP) lattice core sandwich structure hinders its application. In this paper, a typical connection of two lattice core sandwich panels, named as corner joint or L-joint, was investigated by experiment and finite element method (FEM). The mechanical behavior and failure mode of the corner joints were discussed. The results showed that the main deformation pattern and failure mode of the lattice core sandwich bolted corner joints structure were the deformation of metal connector and indentation of the face sheet in the bolt holes. The metal connectors played an important role in bolted corner joints structure. In order to save the calculation resource, a continuum model of pyramid lattice core was used to replace the exact structure. The computation results were consistent with experiment, and the maximum error was 19%. The FEM demonstrated the deflection process of the bolted corner joints structure visually. So the simplified FEM can be used for further analysis of the bolted corner joints structure in engineering.

  13. Geometrically nonlinear analysis of adhesively bonded joints

    NASA Technical Reports Server (NTRS)

    Dattaguru, B.; Everett, R. A., Jr.; Whitcomb, J. D.; Johnson, W. S.

    1982-01-01

    A geometrically nonlinear finite element analysis of cohesive failure in typical joints is presented. Cracked-lap-shear joints were chosen for analysis. Results obtained from linear and nonlinear analysis show that nonlinear effects, due to large rotations, significantly affect the calculated mode 1, crack opening, and mode 2, inplane shear, strain-energy-release rates. The ratio of the mode 1 to mode 2 strain-energy-relase rates (G1/G2) was found to be strongly affected by he adhesive modulus and the adherend thickness. The ratios between 0.2 and 0.8 can be obtained by varying adherend thickness and using either a single or double cracked-lap-shear specimen configuration. Debond growth rate data, together with the analysis, indicate that mode 1 strain-energy-release rate governs debond growth. Results from the present analysis agree well with experimentally measured joint opening displacements.

  14. Behavior of single lap composite bolted joint under traction loading: Experimental investigation

    NASA Astrophysics Data System (ADS)

    Awadhani, L. V.; Bewoor, Anand

    2018-04-01

    Composite bolted joints are preferred connection in the composite structures to facilitate the dismantling for the replacements/ maintenance work. The joint behavior under tractive forces has been studied in order to understand the safety of the structure designed. The main objective of this paper is to investigate the behavior of single-lap joints in carbon fiber reinforced epoxy composites under traction loading conditions. The experiments were designed to identify the effect of bolt diameter, stacking sequence and loading rate on the properties of the joint. The experimental results show that the parameters influence the joint performance significantly.

  15. Evaluation of narrow transverse contraction joints in jointed plain concrete pavements.

    DOT National Transportation Integrated Search

    2006-03-01

    This report presents the results of a research project conducted at the Louisiana Transportation Research Center (LTRC) to evaluate the performance of narrow transverse contraction joints to control cracking in jointed plain concrete pavements. In ad...

  16. Longitudinal joint treatment : construction report.

    DOT National Transportation Integrated Search

    2000-05-01

    Maine highways have been showing signs of longitudinal joint failure for a number of : years. In an effort to reduce the amount of joint failures the Maine Department of : Transportation (MDOT) is currently evaluating two projects. One project is mon...

  17. Acoustic emission analysis: A test method for metal joints bonded by adhesives

    NASA Technical Reports Server (NTRS)

    Brockmann, W.; Fischer, T.

    1978-01-01

    Acoustic emission analysis is applied to study adhesive joints which had been subjected to mechanical and climatic stresses, taking into account conditions which make results applicable to adhesive joints used in aerospace technology. Specimens consisting of the alloy AlMgSi0.5 were used together with a phenolic resin adhesive, an epoxy resin modified with a polyamide, and an epoxy resin modified with a nitrile. Results show that the acoustic emission analysis provides valuable information concerning the behavior of adhesive joints under load and climatic stresses.

  18. Joint measurement of multiple noncommuting parameters

    NASA Astrophysics Data System (ADS)

    Li, Jiamin; Liu, Yuhong; Cui, Liang; Huo, Nan; Assad, Syed M.; Li, Xiaoying; Ou, Z. Y.

    2018-05-01

    Although quantum metrology allows us to make precision measurements beyond the standard quantum limit, it mostly works on the measurement of only one observable due to the Heisenberg uncertainty relation on the measurement precision of noncommuting observables for one system. In this paper, we study the schemes of joint measurement of multiple observables which do not commute with each other using the quantum entanglement between two systems. We focus on analyzing the performance of a SU(1,1) nonlinear interferometer on fulfilling the task of joint measurement. The results show that the information encoded in multiple noncommuting observables on an optical field can be simultaneously measured with a signal-to-noise ratio higher than the standard quantum limit, and the ultimate limit of each observable is still the Heisenberg limit. Moreover, we find a resource conservation rule for the joint measurement.

  19. Effect of intraarticular tramadol administration in the rat model of knee joint inflammation.

    PubMed

    Garlicki, Jarosław; Dorazil-Dudzik, Magdalena; Wordliczek, Jerzy; Przewłocka, Barbara

    2006-01-01

    Local administration of exogenous opioids may cause effective analgesia without adverse symptoms from the central nervous system. Experiments show that peripheral antinociceptive effect of opioids is observed especially in inflammatory pain. The aim of the research was to estimate the effect of tramadol on nociceptive process at the level of peripheral nervous system, after its local administration in the model of knee joint inflammation. Tramadol was administered intraarticulary into the rat knee joint, before the inflammation as a preemptive analgesia and, for comparison, after the intraarticular injection of carrageenan. The research determined the influence of tramadol injection on pain threshold for thermal stimuli, development of inflammatory processes using the measurement of joint edema and motor function following the induction of knee joint inflammation in the rat. Functional assessment of knee joint with inflammation, in terms of rats' mobility and body position as well as joint loading and mobility were studied. The results of the experiments show that local administration of tramadol induces antinociceptive effect. The effect of tramadol, which elicits also a decrease in inflammatory edema, appears not only after its administration after carrageenan when inflammation was already present, but also in the case of its injection prior to carrageenan in the scheme of preemptive analgesia. The results of the described research show that not only morphine but also another opioid, tramadol, widely used in clinical practice, inhibits nociception, edema and functional impairment of the paw after its local application directly to the inflamed knee joint.

  20. Optimum design of Geodesic dome’s jointing system

    NASA Astrophysics Data System (ADS)

    Tran, Huy. T.

    2018-04-01

    This study attempts to create a new design for joint connector of Geodesic dome. A new type of joint connector design is proposed for flexible rotating connection; comparing it to another, this design is cheaper and workable. After calculating the bearing capacity of the sample according to EC3 and Vietnam standard TCVN 5575-2012, FEM model of the design sample is carried out in many specific situation to consider the stress distribution, the deformation, the local destruction… in the connector. The analytical results and the FE data are consistent. The FE analysis also points out the behavior of some details that simple calculation cannot show. Hence, we can choose the optimum design of joint connector.

  1. Influence of the implant-abutment connection design and diameter on the screw joint stability

    PubMed Central

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung

    2014-01-01

    PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398

  2. Gene-expression changes in knee-joint tissues with aging and menopause: implications for the joint as an organ

    PubMed Central

    Rollick, Natalie C; Lemmex, Devin B; Ono, Yohei; Reno, Carol R; Hart, David A; Lo, Ian KY; Thornton, Gail M

    2018-01-01

    Background When considering the “joint as an organ”, the tissues in a joint act as complementary components of an organ, and the “set point” is the cellular activity for homeostasis of the joint tissues. Even in the absence of injury, joint tissues have adaptive responses to processes, like aging and menopause, which result in changes to the set point. Purpose The purpose of this study in a preclinical model was to investigate age-related and menopause-related changes in knee-joint tissues with the hypothesis that tissues will change in unique ways that reflect their differing contributions to maintaining joint function (as measured by joint laxity) and the differing processes of aging and menopause. Methods Rabbit knee-joint tissues from three groups were evaluated: young adult (gene expression, n=8; joint laxity, n=7; water content, n=8), aging adult (gene expression, n=6; joint laxity, n=7; water content, n=5), and menopausal adult (gene expression, n=8; joint laxity, n=7; water content, n=8). Surgical menopause was induced with ovariohysterectomy surgery and gene expression was assessed using reverse-transcription quantitative polymerase chain reaction. Results Aging resulted in changes to 37 of the 150 gene–tissue combinations evaluated, and menopause resulted in changes to 39 of the 150. Despite the similar number of changes, only eleven changes were the same in both aging and menopause. No differences in joint laxity were detected comparing young adult rabbits with aging adult rabbits or with menopausal adult rabbits. Conclusion Aging and menopause affected the gene-expression patterns of the tissues of the knee joint differently, suggesting unique changes to the set point of the knee. Interestingly, aging and menopause did not affect knee-joint laxity, suggesting that joint function was maintained, despite changes in gene expression. Taken together, these findings support the theory of the joint as an organ where the tissues of the joint adapt to

  3. Clinical Incidence of Sacroiliac Joint Arthritis and Pain after Sacropelvic Fixation for Spinal Deformity

    PubMed Central

    Sainoh, Takeshi; Takaso, Masashi; Inoue, Gen; Orita, Sumihisa; Eguchi, Yawara; Nakamura, Junichi; Aoki, Yasuchika; Ishikawa, Tetsuhiro; Miyagi, Masayuki; Arai, Gen; Kamoda, Hiroto; Suzuki, Miyako; Kubota, Gou; Sakuma, Yoshihiro; Oikawa, Yasuhiro; Yamazaki, Masashi; Toyone, Tomoaki; Takahashi, Kazuhisa

    2012-01-01

    Purpose Sacroiliac fixation using iliac screws for highly unstable lumbar spine has been reported with an improved fusion rate and clinical results. On the other hand, there is a potential for clinical problems related to iliac fixation, including late sacroiliac joint arthritis and pain. Materials and Methods Twenty patients were evaluated. Degenerative scoliosis was diagnosed in 7 patients, failed back syndrome in 6 patients, destructive spondyloarthropathy in 4 patients, and Charcot spine in 3 patients. All patients underwent posterolateral fusion surgery incorporating lumbar, S1 and iliac screws. We evaluated the pain scores, bone union, and degeneration of sacroiliac joints by X-ray imaging and computed tomography before and 3 years after surgery. For evaluation of low back and buttock pain from sacroiliac joints 3 years after surgery, lidocaine was administered in order to examine pain relief thereafter. Results Pain scores significantly improved after surgery. All patients showed bone union at final follow-up. Degeneration of sacroiliac joints was not seen in the 20 patients 3 years after surgery. Patients showed slight low back and buttock pain 3 years after surgery. However, not all patients showed relief of the low back and buttock pain after injection of lidocaine into the sacroiliac joint, indicating that their pain did not originate from sacroiliac joints. Conclusion The fusion rate and clinical results were excellent. Also, degeneration and pain from sacroiliac joints were not seen within 3 years after surgery. We recommend sacroiliac fixation using iliac screws for highly unstable lumbar spine. PMID:22318832

  4. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    PubMed

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  5. A parametric shell analysis of the shuttle 51-L SRB AFT field joint

    NASA Technical Reports Server (NTRS)

    Davis, Randall C.; Bowman, Lynn M.; Hughes, Robert M., IV; Jackson, Brian J.

    1990-01-01

    Following the Shuttle 51-L accident, an investigation was conducted to determine the cause of the failure. Investigators at the Langley Research Center focused attention on the structural behavior of the field joints with O-ring seals in the steel solid rocket booster (SRB) cases. The shell-of-revolution computer program BOSOR4 was used to model the aft field joint of the solid rocket booster case. The shell model consisted of the SRB wall and joint geometry present during the Shuttle 51-L flight. A parametric study of the joint was performed on the geometry, including joint clearances, contact between the joint components, and on the loads, induced and applied. In addition combinations of geometry and loads were evaluated. The analytical results from the parametric study showed that contact between the joint components was a primary contributor to allowing hot gases to blow by the O-rings. Based upon understanding the original joint behavior, various proposed joint modifications are shown and analyzed in order to provide additional insight and information. Finally, experimental results from a hydro-static pressurization of a test rocket booster case to study joint motion are presented and verified analytically.

  6. Correlation between osteoarthritic changes in the stifle joint in dogs and the results of orthopedic, radiographic, ultrasonographic and arthroscopic examinations.

    PubMed

    Ramírez-Flores, Gabriel Ignacio; Del Angel-Caraza, Javier; Quijano-Hernández, Israel Alejandro; Hulse, Don A; Beale, Brian S; Victoria-Mora, José Mauro

    2017-06-01

    Osteoarthritis (OA) is a chronic, degenerative disease affecting the articular cartilage and subchondral bone that causes pain and inhibits movement. The stifle's joint fibrous capsule contains the synovial membrane, which produces cartilage nutrients. A ruptured cranial cruciate ligament injures the joint and produces OA. Osteoarthritis diagnosis starts with clinical radiographic and ultrasonographic tests, although the latter is not used very much in dog and cat clinics for this purpose. The objective of this study was to establish the correlation among the results of orthopedic, radiographic, ultrasonographic examinations and structural anatomical changes revealed by arthroscopic evaluation to diagnose stifle joint OA and determine risk factors in the dogs affected. Of 44 clinical cases of OA included in the study, 88.64% had ruptured of cranial cruciate ligaments. The correlation between synovial fluid effusion and osteophytosis was of 0.84. It was concluded that there is good diagnostic agreement between synovial fluid effusion and osteophytosis when dealing with stifle joint OA. Risk factors for dogs regarding the development of stifle joint OA included: ruptured cranial cruciate ligaments or patella luxation, female dogs and weight over 10 kg.

  7. The mechanoreceptors of the costo-vertebral joints

    PubMed Central

    Godwin-Austen, R. B.

    1969-01-01

    1. Unitary recording in the thoracic dorsal roots of mechanoreceptor discharges from the costo-vertebral joints was carried out in the cat and rabbit. Criteria for the identification of costo-vertebral joint mechanoreceptors were established. 2. The majority of rib joint mechanoreceptors are slowly adapting and fifty-three such receptors were studied. Five rapidly adapting receptors were also identified. 3. The responses of these receptors have been correlated with rib position and movement. The slowly adapting receptors gave a monotonic response to different rib positions. 72% showed an increase of discharge rate with displacements towards expiratory rib positions. 4. In response to manually imposed rib movements slowly adapting joint mechanoreceptors gave a dynamic response which was directly related to the velocity of the movement and adapted within 2 sec. The movements of breathing produced a corresponding alteration of the discharge frequency of the slowly adapting receptors. 5. Slowly adapting receptors were localized to the capsule of the costo-transverse joint by probing. They responded to increased intra-articular pressure with an increase of discharge rate and were silenced by intra-articular lignocaine, 0·4%. 6. Rapidly adapting joint mechanoreceptors responded to rib movement with a brief burst of discharges. 7. The rib joint mechanoreceptors signal rib joint position, and the direction and velocity of rib movement. It is suggested that these afferent discharges provide the basis for the perception of respiratory movements of the chest. The significance of these receptors to the `sense of effort' resulting from a resistance to breathing is discussed. PMID:5789947

  8. Joint Action Coordination in 2½- and 3-Year-Old Children

    PubMed Central

    Meyer, Marlene; Bekkering, Harold; Paulus, Markus; Hunnius, Sabine

    2010-01-01

    When acting jointly with others, adults can be as proficient as when acting individually. However, how young children coordinate their actions with another person and how their action coordination develops during early childhood is not well understood. By means of a sequential button-pressing game, which could be played jointly or individually, the action coordination of 2½- and 3-year-old children was examined. Performance accuracy and variability of response timing were taken as indicators of coordination ability. Results showed substantial improvement in joint action coordination between the age of 2½ and 3, but both age groups performed equally well when acting individually. Interestingly, 3-year-olds performed equally well in the joint and the individual condition, whereas 2½-year-olds did not yet show this adult-like pattern as indicated by less accurate performance in the joint action. The findings suggest that in contrast to 3-year-olds, 2½-year-olds still have difficulties in establishing well-coordinated joint action with an adult partner. Possible underlying cognitive abilities such as action planning and action control are discussed. PMID:21165176

  9. Recrystallization Behavior in Mixed Solder Joints of BGA Components during Thermal Shock

    NASA Astrophysics Data System (ADS)

    Tan, Shihai; Han, Jing; Guo, Fu

    2018-03-01

    Sn-37Pb and Sn-3.0Ag-0.5Cu solder pastes printed onto a board were attached to ball grid array (BGA) samples using Sn-3.0Ag-0.5Cu solder balls. Before thermal shock, the initial grain orientations on the cross-section were obtained by scanning electron microscopy equipped with an electron backscattered diffraction system. Three mixed solder joints (two from the corner and another from the middle of the BGA component) and three lead-free solder joints (at the same positions) were selected to investigate the recrystallization behavior under thermal shock (TS) cycling conditions. All of the mixed and lead-free solder joints were initially single crystal. The results showed that recrystallization occurred in both the mixed and lead-free solder joints after 200 TS. For the mixed solder joints, more recrystallization was observed and the location of samples had a significant influence on their recrystallization behavior, while location was not as important for the lead-free samples after 200 TS in this study. Both the mixed and lead-free solder joints at the corner of BGA components showed the poorest reliability. According to misorientation distribution maps and subgrain rotation behaviors, the reliability of mixed solder joints was much poorer than that of lead-free solder joints.

  10. Sustained inhibition of progressive joint damage with rituximab plus methotrexate in early active rheumatoid arthritis: 2-year results from the randomised controlled trial IMAGE.

    PubMed

    Tak, Paul P; Rigby, William; Rubbert-Roth, Andrea; Peterfy, Charles; van Vollenhoven, Ronald F; Stohl, William; Healy, Emma; Hessey, Eva; Reynard, Mark; Shaw, Tim

    2012-03-01

    In the IMAGEstudy, rituximab plus methotrexate (MTX) inhibited joint damage and improved clinical outcomes at 1 year in MTX-naïve patients with early active rheumatoid arthritis. The aim of this study was to assess joint damage progression and clinical outcomes over 2 years. Patients (n=755) were randomised to receive rituximab 2×500 mg+MTX, 2×1000 mg+MTX or placebo+MTX. The placebo-controlled period continued to week 104. Two-year end points were defined as secondary or exploratory and included change in total Genant-modified Sharp score (mTSS), total erosion score and joint space narrowing score from baseline to week 104. Clinical efficacy and physical function end points were also assessed. At 2 years, rituximab 2×1000 mg+MTX maintained inhibition of progressive joint damage versus MTX alone (mTSS change 0.41 vs 1.95; p<0.0001 (79% inhibition)), and a higher proportion of patients receiving rituximab 2×1000 mg+MTX had no radiographic progression over 2 years compared with those receiving MTX alone (57% vs 37%; p<0.0001). Contrary to 1-year results, exploratory analysis of rituximab 2×500 mg+MTX at 2 years showed that progressive joint damage was slowed by ∼61% versus placebo+MTX (mTSS, exploratory p=0.0041). Improvements in clinical signs and symptoms and physical function seen after 1 year in rituximab-treated patients versus those receiving placebo were maintained at year 2. Safety profiles were similar between groups. Treatment with rituximab 2×1000 mg+MTX was associated with sustained improvements in radiographic, clinical and functional outcomes over 2 years. Clinical trials.gov identifier NCT00299104.

  11. Structural Performance of Inconel 625 Superalloy Brazed Joints

    NASA Astrophysics Data System (ADS)

    Chen, Jianqiang; Demers, Vincent; Cadotte, Eve-Line; Turner, Daniel; Bocher, Philippe

    2017-02-01

    The purpose of this work was to investigate tensile and fatigue behaviors of Inconel 625 superalloy brazed joints after transient liquid-phase bonding process. Brazing was performed in a vacuum furnace using a nickel-based filler metal in a form of paste to join wrought Inconel 625 plates. Mechanical tests were carried out on single-lap joints under various lap distance-to-thickness ratios. The fatigue crack initiation and crack growth modes were examined via metallographic analysis, and the effect of local stress on fatigue life was assessed by finite element simulations. The fatigue results show that fatigue strength and endurance limit increase with overlap distance, leading to a relatively large scatter of results. Fatigue cracks nucleated in the high-stressed region of the weld fillets from brittle eutectic phases or from internal brazing cavities. The present work proposes to rationalize the results by using the local stress at the brazing fillet. When using this local stress, all fatigue-obtained results find themselves on a single S- N curve, providing a design curve for any joint configuration in fatigue solicitation.

  12. Experimental cryo-irrigation of the knee joint.

    PubMed

    Chen, S C; Helal, B; Revell, P A; Brocklehurst, R; Currey, H L

    1986-10-01

    Experiments have been carried out to test the feasibility of using cryo-irrigation as a means of ablating the synovium in the rheumatoid knee joint. Cryo-irrigation was performed by a cooling machine and pump, which circulated cold 200/10 centistoke (cSt) silicone through the knee joint of rabbits anaesthetised with intravenous (IV) 'Saffan'. Fluid left the joint at -5 to -10 degrees C. Sixteen normal New Zealand rabbits received cryo-irrigation of one knee joint for 10-20 minutes and were killed at one day, and one, two, and 12 weeks thereafter. Judged by radioactive sulphate incorporation there was no impairment of chondrocyte function in the articular cartilage of irrigated joints. Histological examination showed mild synovitis and some loss of staining of superficial cartilage in 6/16 irrigated joints (v 1/16 control joints). Similar treatment of rabbit joints in which the Glynn model of synovitis had been induced showed marked reduction of synovitis 14-45 days after silicone treatment. Nine of 26 animals in which synovitis was induced in both knees and cryo-irrigation performed in one knee died either immediately postoperatively or during the next week. These deaths remain unexplained. A single dog received cryo-irrigation of one knee (-6 to -9 degrees C for 22 min) and remained perfectly well up to sacrifice at six months, when the joint appeared histologically completely normal.

  13. Adaptive Postural Control for Joint Immobilization during Multitask Performance

    PubMed Central

    Hsu, Wei-Li

    2014-01-01

    Motor abundance is an essential feature of adaptive control. The range of joint combinations enabled by motor abundance provides the body with the necessary freedom to adopt different positions, configurations, and movements that allow for exploratory postural behavior. This study investigated the adaptation of postural control to joint immobilization during multi-task performance. Twelve healthy volunteers (6 males and 6 females; 21–29 yr) without any known neurological deficits, musculoskeletal conditions, or balance disorders participated in this study. The participants executed a targeting task, alone or combined with a ball-balancing task, while standing with free or restricted joint motions. The effects of joint configuration variability on center of mass (COM) stability were examined using uncontrolled manifold (UCM) analysis. The UCM method separates joint variability into two components: the first is consistent with the use of motor abundance, which does not affect COM position (VUCM); the second leads to COM position variability (VORT). The analysis showed that joints were coordinated such that their variability had a minimal effect on COM position. However, the component of joint variability that reflects the use of motor abundance to stabilize COM (VUCM) was significant decreased when the participants performed the combined task with immobilized joints. The component of joint variability that leads to COM variability (VORT) tended to increase with a reduction in joint degrees of freedom. The results suggested that joint immobilization increases the difficulty of stabilizing COM when multiple tasks are performed simultaneously. These findings are important for developing rehabilitation approaches for patients with limited joint movements. PMID:25329477

  14. Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

    PubMed

    Aeyels, B; Peeraer, L; Vander Sloten, J; Van der Perre, G

    1992-05-01

    The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Study of sealing practices for rigid pavement joints.

    DOT National Transportation Integrated Search

    1971-01-01

    The joint sealing materials and the rigid pavement joint sealing practices employed by Virginia and other highway agencies were studied. The studies showed that Virginia's sealant and joint designs were in need of updating and that higher quality pou...

  16. Model-Based Estimation of Ankle Joint Stiffness

    PubMed Central

    Misgeld, Berno J. E.; Zhang, Tony; Lüken, Markus J.; Leonhardt, Steffen

    2017-01-01

    We address the estimation of biomechanical parameters with wearable measurement technologies. In particular, we focus on the estimation of sagittal plane ankle joint stiffness in dorsiflexion/plantar flexion. For this estimation, a novel nonlinear biomechanical model of the lower leg was formulated that is driven by electromyographic signals. The model incorporates a two-dimensional kinematic description in the sagittal plane for the calculation of muscle lever arms and torques. To reduce estimation errors due to model uncertainties, a filtering algorithm is necessary that employs segmental orientation sensor measurements. Because of the model’s inherent nonlinearities and nonsmooth dynamics, a square-root cubature Kalman filter was developed. The performance of the novel estimation approach was evaluated in silico and in an experimental procedure. The experimental study was conducted with body-worn sensors and a test-bench that was specifically designed to obtain reference angle and torque measurements for a single joint. Results show that the filter is able to reconstruct joint angle positions, velocities and torque, as well as, joint stiffness during experimental test bench movements. PMID:28353683

  17. Longitudinal joint treatment : first interim report.

    DOT National Transportation Integrated Search

    2000-11-01

    Maine highways have been showing signs of longitudinal joint failure for a number of : years. In an effort to reduce the amount of joint failures the Maine Department of : Transportation (MDOT) is currently evaluating two projects. One project is mon...

  18. Longitudinal joint treatment : second interim report.

    DOT National Transportation Integrated Search

    2001-09-01

    Maine highways have been showing signs of longitudinal joint failure for a : number of years. In an effort to reduce the amount of joint failures the Maine : Department of Transportation (MDOT) is currently evaluating two projects. One : project is m...

  19. Shear fracture of jointed steel plates of bolted joints under impact load

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.; Kobayashi, H.; Shin, H.-S.

    2013-07-01

    The present study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of bolted joints used in a car body, which contributes to crash simulations by CAE. We focus our attention on the shear fracture of the jointed steel plates of lap-bolted joints in the suspension of a car under impact load. Members of lap-bolted joints are modelled as a pair of steel plates connected by a bolt. One of the plates is a specimen subjected to plastic deformation and fracture and the other is a jig subjected to elastic deformation only. Three kinds of steel plate specimens are examined, i.e., a common steel plate with a tensile strength of 270 MPa and high tensile strength steel plates of 440 and 590 MPa used for cars. The impact shear test was performed using the split Hopkinson bar technique for tension impact, together with the static test using a universal testing machine INSTRON 5586. The behaviour of the shear stress and deformation up to rupture taking place in the joint was discussed. The obtained results suggest that a stress-based fracture criterion may be developed for the impact fracture of jointed steel plates of a lap-bolted joint.

  20. Factors affecting results of fluoroscopy-guided facet joint injection: Probable differences in the outcome of treatment between pure facet joint hypertrophy and concomitant diseases.

    PubMed

    Albayrak, Akif; Ozkul, Baris; Balioglu, Mehmet Bulent; Atici, Yunus; Gultekin, Muhammet Zeki; Albayrak, Merih Dilan

    2016-01-01

    Retrospective cohort study. Facet joints are considered a common source of chronic low-back pain. To determine whether pathogens related to the facet joint arthritis have any effect on treatment failure. Facet joint injection was applied to 94 patients treated at our hospital between 2011 and 2012 (mean age 59.5 years; 80 women and 14 men). For the purpose of analysis, the patients were divided into two groups. Patients who only had facet hypertrophy were placed in group A (47 patients, 41 women and 6 men, mean age 55.3 years) and patients who had any additional major pathology to facet hypertrophy were placed in group B (47 patients, 39 women and 8 men, mean age 58.9 years). Injections were applied around the facet joint under surgical conditions utilizing fluoroscopy device guidance. A mixture of methylprednisolone and lidocaine was used as the injection ingredient. In terms of Oswestry Disability Index (ODI) and visual analog scale (VAS) scores, no significant difference was found between preinjection and immediate postinjection values in both groups, and the scores of group A patients were significantly lower (P < 0.005) compared with that of group B patients at the end of the third, sixth, and twelfth month. For low-back pain caused by facet hypertrophy, steroid injection around the facet joint is an effective treatment, but if there is an existing major pathology, it is not as effective.

  1. Thermographic Analysis of Stress Distribution in Welded Joints

    NASA Astrophysics Data System (ADS)

    Piršić, T.; Krstulović Opara, L.; Domazet, Ž.

    2010-06-01

    The fatigue life prediction of welded joints based on S-N curves in conjunction with nominal stresses generally is not reliable. Stress distribution in welded area affected by geometrical inhomogeneity, irregular welded surface and weld toe radius is quite complex, so the local (structural) stress concept is accepted in recent papers. The aim of this paper is to determine the stress distribution in plate type aluminum welded joints, to analyze the reliability of TSA (Thermal Stress Analysis) in this kind of investigations, and to obtain numerical values for stress concentration factors for practical use. Stress distribution in aluminum butt and fillet welded joints is determined by using the three different methods: strain gauges measurement, thermal stress analysis and FEM. Obtained results show good agreement - the TSA mutually confirmed the FEM model and stresses measured by strain gauges. According to obtained results, it may be stated that TSA, as a relatively new measurement technique may in the future become a standard tool for the experimental investigation of stress concentration and fatigue in welded joints that can help to develop more accurate numerical tools for fatigue life prediction.

  2. Joint design of QC-LDPC codes for coded cooperation system with joint iterative decoding

    NASA Astrophysics Data System (ADS)

    Zhang, Shunwai; Yang, Fengfan; Tang, Lei; Ejaz, Saqib; Luo, Lin; Maharaj, B. T.

    2016-03-01

    In this paper, we investigate joint design of quasi-cyclic low-density-parity-check (QC-LDPC) codes for coded cooperation system with joint iterative decoding in the destination. First, QC-LDPC codes based on the base matrix and exponent matrix are introduced, and then we describe two types of girth-4 cycles in QC-LDPC codes employed by the source and relay. In the equivalent parity-check matrix corresponding to the jointly designed QC-LDPC codes employed by the source and relay, all girth-4 cycles including both type I and type II are cancelled. Theoretical analysis and numerical simulations show that the jointly designed QC-LDPC coded cooperation well combines cooperation gain and channel coding gain, and outperforms the coded non-cooperation under the same conditions. Furthermore, the bit error rate performance of the coded cooperation employing jointly designed QC-LDPC codes is better than those of random LDPC codes and separately designed QC-LDPC codes over AWGN channels.

  3. Interfacial and Mechanical Behavior of AA5456 Filling Friction-Stir-Welded Lap Joints Using Similar and Dissimilar Pins

    NASA Astrophysics Data System (ADS)

    Behmand, Saleh Alaei; Mirsalehi, Seyyed Ehsan; Omidvar, Hamid; Safarkhanian, Mohammad Ali

    2016-10-01

    In this article, filling friction stir welding (FFSW) of the remaining exit holes of AA5456 alloy friction-stir-welded lap joints was studied. For this purpose, the influences of different rotating speeds, holding times, and pin materials, AA5456 and AA2024, on the metallurgical structure and joint strength were investigated. The observations showed that defect-free lap joints are successfully obtainable by this method using similar and dissimilar consumable pins. The results indicated that the higher rotating speed and holding time adversely affect the weld performance. The best result was achieved for 30 seconds holding time, 500 rpm rotating speed, and AA2024 consumable pin. In this condition, a lap shear strength of 10 pct higher than that of the nonfilled joint, equivalent to about 94 pct of the original defect-free FSW joint, was obtained, whereas the GTAW filled joint showed only approximately 87 pct of the continuous FSW joint strength.

  4. Neuromuscular prehabilitation to prevent osteoarthritis after a traumatic joint injury.

    PubMed

    Tenforde, Adam S; Shull, Pete B; Fredericson, Michael

    2012-05-01

    Post-traumatic osteoarthritis (PTOA) is a process resulting from direct forces applied to a joint that cause injury and degenerative changes. An estimated 12% of all symptomatic osteoarthritis (OA) of the hip, knee, and ankle can be attributed to a post-traumatic cause. Neuromuscular prehabilitation is the process of improving neuromuscular function to prevent development of PTOA after an initial traumatic joint injury. Prehabilitation strategies include restoration of normative movement patterns that have been altered as the result of traumatic injury, along with neuromuscular exercises and gait retraining to prevent the development of OA after an injury occurs. A review of the current literature shows that no studies have been performed to evaluate methods of neuromuscular prehabilitation to prevent PTOA after a joint injury. Instead, current research has focused on management strategies after knee injuries, the value of exercise in the management of OA, and neuromuscular exercises after total knee arthroplasty. Recent work in gait retraining that alters knee joint loading holds promise for preventing the development of PTOA after joint trauma. Future research should evaluate methods of neuromuscular prehabilitation strategies in relationship to the outcome of PTOA after joint injury. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  5. Anand constitutive model of lead-free solder joints in 3D IC device

    NASA Astrophysics Data System (ADS)

    Zhang, Liang; Liu, Zhi-quan; Ji, Yu-tong

    2016-08-01

    Anand constitutive relation of SnAgCu and SnAgCu-nano Al solders were studied under uniaxial tension, and the constitutive model was used in the finite element simulation to analyze the stress-strain response of lead-free solder joints in 3D IC devices. The results showed that the nine parameters of the Anand model can be determined from separated constitutive relations and experimental results. Based on Anand model, the finite element method was selected to calculate the stress-strain response of lead-free solder joints, it was found that in the 3D IC device the maximum stress-strain concentrated in the concern solder joints, the stress-strain of SnAgCu-nano Al solder joints was lower than that of SnAgCu solder joints, which represented that the addition of nano Al particles can enhance the reliability of lead-free solder joints in 3D IC devices.

  6. Sensate Scaffolds Can Reliably Detect Joint Loading

    PubMed Central

    Bliss, C. L.; Szivek, J. A.; Tellis, B. C.; Margolis, D. S.; Schnepp, A. B.; Ruth, J. T.

    2008-01-01

    Treatment of cartilage defects is essential to the prevention of osteoarthritis. Scaffold-based cartilage tissue engineering shows promise as a viable technique to treat focal defects. Added functionality can be achieved by incorporating strain gauges into scaffolds, thereby providing a real-time diagnostic measurement of joint loading. Strain-gauged scaffolds were placed into the medial femoral condyles of 14 adult canine knees and benchtop tested. Loads between 75 and 130 N were applied to the stifle joints at 30°, 50°, and 70° of flexion. Strain-gauged scaffolds were able to reliably assess joint loading at all applied flexion angles and loads. Pressure sensitive films were used to determine joint surface pressures during loading and to assess the effect of scaffold placement on joint pressures. A comparison of peak pressures in control knees and joints with implanted scaffolds, as well as a comparison of pressures before and after scaffold placement, showed that strain-gauged scaffold implantation did not significantly alter joint pressures. Future studies could possibly use strain-gauged scaffolds to clinically establish normal joint loads and to determine loads that are damaging to both healthy and tissue-engineered cartilage. Strain-gauged scaffolds may significantly aid the development of a functional engineered cartilage tissue substitute as well as provide insight into the native environment of cartilage. PMID:16941586

  7. Rubber Hand Illusion Affects Joint Angle Perception

    PubMed Central

    Butz, Martin V.; Kutter, Esther F.; Lorenz, Corinna

    2014-01-01

    The Rubber Hand Illusion (RHI) is a well-established experimental paradigm. It has been shown that the RHI can affect hand location estimates, arm and hand motion towards goals, the subjective visual appearance of the own hand, and the feeling of body ownership. Several studies also indicate that the peri-hand space is partially remapped around the rubber hand. Nonetheless, the question remains if and to what extent the RHI can affect the perception of other body parts. In this study we ask if the RHI can alter the perception of the elbow joint. Participants had to adjust an angular representation on a screen according to their proprioceptive perception of their own elbow joint angle. The results show that the RHI does indeed alter the elbow joint estimation, increasing the agreement with the position and orientation of the artificial hand. Thus, the results show that the brain does not only adjust the perception of the hand in body-relative space, but it also modifies the perception of other body parts. In conclusion, we propose that the brain continuously strives to maintain a consistent internal body image and that this image can be influenced by the available sensory information sources, which are mediated and mapped onto each other by means of a postural, kinematic body model. PMID:24671172

  8. Flaw Tolerance in Lap Shear Brazed Joints. Part 1

    NASA Technical Reports Server (NTRS)

    Flom, Yury; Wang, Li-Qin

    2003-01-01

    Furnace brazing is a joining process used in the aerospace and other industries to produce strong permanent and hermetic structural joints. As in any joining process, brazed joints have various imperfections and defects. At the present time, our understanding of the influence of the internal defects on the strength of the brazed joints is not adequate. The goal of this 3-part investigation is to better understand the properties and failure mechanisms of the brazed joints containing defects. This study focuses on the behavior of the brazed lap shear joints because of their importance in manufacturing aerospace structures. In Part 1, an average shear strength capability and failure modes of the single lap joints are explored. Stainless steel specimens brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the failure loads and the ultimate shear strength with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap widths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. A damage zone criterion is shown to work quite well in understanding the failure of the braze joints. In Part 2, the findings of the Part 1 will be verified on the larger test specimens. Also, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify that behavior of the flawed ductile lap joints is similar to joints with a reduced braze area. Finally, in Part 3, the results obtained in Parts 1 and 2 will be applied to the actual brazed structure to evaluate the load-carrying capability of a structural lap joint containing discontinuities. In addition, a simplified engineering procedure will be offered for the laboratory testing of the lap shear specimens.

  9. Early medication use in new-onset rheumatoid arthritis may delay joint replacement: results of a large population-based study.

    PubMed

    Moura, Cristiano S; Abrahamowicz, Michal; Beauchamp, Marie-Eve; Lacaille, Diane; Wang, Yishu; Boire, Gilles; Fortin, Paul R; Bessette, Louis; Bombardier, Claire; Widdifield, Jessica; Hanly, John G; Feldman, Debbie; Maksymowych, Walter; Peschken, Christine; Barnabe, Cheryl; Edworthy, Steve; Bernatsky, Sasha

    2015-08-03

    Use of disease-modifying anti-rheumatic drugs (DMARDs) in rheumatoid arthritis (RA) may prevent joint damage and potentially reduce joint replacement surgeries. We assessed the association between RA drug use and joint replacement in Quebec, Canada. A cohort of new-onset RA patients was identified from Quebec's physician billing and hospitalization databases from 2002-2011. The outcome was defined using procedure codes submitted by orthopedic surgeons. Medication use was obtained from pharmacy databases. We used alternative Cox regression models with time-dependent variables measuring the cumulative effects of past use during different time windows (one model focussing on the first year after cohort entry) for methotrexate (MTX), and other DMARDs. Models were adjusted for baseline sociodemographics, co-morbidity and prior health service use, time-dependent cumulative use of other drugs (anti-tumor necrosis factor [anti-TNF] agents, other biologics, cyclooxygenase-2 inhibitors [COXIBs], nonselective nonsteroidal antiinflammatory drugs [NSAIDs], and systemic steroids), and markers of disease severity. During follow-up, 608 joint replacements occurred among 11,333 patients (median follow-up: 4.6 years). The best-fitting model relied on the cumulative early use (within the first year after cohort entry) of MTX and of other DMARDs, with an interaction between MTX and other DMARDs. In this model, greater exposure within the first year, to either MTX (adjusted hazard ratio, HR = 0.95 per 1 month, 95% confidence interval, 95% CI 0.93-0.97) or other DMARDs (HR = 0.97, 95% CI 0.95-0.99) was associated with longer time to joint replacement. Our results suggest that longer exposure to either methotrexate (MTX) or other DMARDs within the first year after RA diagnosis is associated with longer time to joint replacement surgery.

  10. Artificial atlanto-odontoid joint replacement through a transoral approach.

    PubMed

    Lu, Bin; He, Xi Jing; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2009-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P B 0.021) and NZ (P B 0.002) and a significantly increased stiffness (P \\ 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P C 0.719), NZ (P C 0.580), and stiffness (P C 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test

  11. Artificial atlanto-odontoid joint replacement through a transoral approach

    PubMed Central

    Lu, Bin; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2008-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1–C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P ≤ 0.021) and NZ (P ≤ 0.002) and a significantly increased stiffness (P < 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P ≥ 0.719), NZ (P ≥ 0.580), and stiffness (P ≥ 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and

  12. Strength evaluation of socket joints

    NASA Technical Reports Server (NTRS)

    Rash, Larry C.

    1994-01-01

    This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.

  13. 13. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF POOR CONSTRUCTION WORK. THOUGH NOT A SERIOUS STRUCTURAL DEFICIENCY, THE 'HONEYCOMB' TEXTURE OF THE CONCRETE SURFACE WAS THE RESULT OF INADEQUATE TAMPING AT THE TIME OF THE INITIAL 'POUR'. - Hume Lake Dam, Sequioa National Forest, Hume, Fresno County, CA

  14. [SOMATOTYPE JOINT MOBILITY AND RANGES OF HIP AND KNEE OF COLLEGE STUDENTS].

    PubMed

    Godoy-Cumillaf, Andrés; Valdés-Badilla, Pablo; García Sandoval, Alan; Grandón Fuentes, Monica; Lagos Del Canto, Loreto; Aravena Turra, Raúl; Herrera-Valenzuela, Tomás; Bruneau Chavez, José; Durán Agüero, Samuel

    2015-12-01

    several studies indicate a consistency between the physical inactivity and low levels of mobility in hip and knee joint. to determine the differences in the motion range of the hip and knee joint between the different classifications of somatotype in students of Pedagogy in Physical Education of the Universidad Autónoma de Chile, campus Temuco. the sample included 102 physical education students (31.3% female), somatotype was obtained through the protocol of the International Society for the Advancement of Kinanthropometry (ISAK) and the motion range of the hip and knee joint (ROM) using a universal goniometer. the mean somatotype was endo-mesomorphic (4.8 - 3.4 - 2) for the women and meso-endomorphic (3.5 - 5.7 - 2) for the males, while the ROM evaluation indicated that the 50% of the students presented mobility values of joint lower than the normal ones. Furthermore, the endo-mesomorphic women showed lower ROM values of medial rotation of the right hip (45.5 ° ± 10.2 °; P = 0.0125, t = 2.732) and left hip side rotation (41.7 ° ± 10.3 °; P = 0.0256; p = 2.402) than the women meso-endomorphic. the results shows a relationship between the somatotype and hip ROM in the women, showing that in the women the most favorable results of joint mobility are related with a greater muscle mass. In contrasts, no significant differences were observed in men. It is important to encourage the development of joint mobility exercises according to the specific needs of each sex. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  15. Mechanical and Functional Properties of Nickel Titanium Adhesively Bonded Joints

    NASA Astrophysics Data System (ADS)

    Niccoli, F.; Alfano, M.; Bruno, L.; Furgiuele, F.; Maletta, C.

    2014-07-01

    In this study, adhesive joints made up of commercial NiTi sheets with shape memory capabilities are analyzed. Suitable surface pre-treatments, i.e., degreasing, sandblasting, and chemical etching, are preliminary compared in terms of surface roughness, surface energy, and substrate thinning. Results indicate that chemical etching induces marked substrate thinning without substantial gains in terms of surface roughness and free energy. Therefore, adhesive joints with degreased and sandblasted substrates are prepared and tested under both static and cyclic conditions, and damage development within the adhesive layer is monitored in situ using a CCD camera. Sandblasted specimens have a significantly higher mechanical static strength with respect to degreased ones, although they essentially fail in similar fashion, i.e., formation of microcracks followed by decohesion along the adhesive/substrate interface. In addition, the joints show a good functional response with almost complete shape memory recovery after thermo-mechanical cycling, i.e., a small accumulation of residual deformations occurs. The present results show that adhesive bonding is a viable joining technique for NiTi alloys.

  16. Thoracic costotransverse joint pain patterns: a study in normal volunteers.

    PubMed

    Young, Brian A; Gill, Howard E; Wainner, Robert S; Flynn, Timothy W

    2008-10-15

    Pain referral patterns of asymptomatic costotransverse joints have not been established. The objective of this study was to determine the pain referral patterns of asymptomatic costotransverse joints via provocative intra-articular injection. Eight asymptomatic male volunteers received a combined total of 21 intra-articular costotransverse joint injections. Fluoroscopic imaging was used to identify and isolate each costotransverse joint and guide placement of a 25 gauge, 2.5 inch spinal needle into the costotransverse joint. Following contrast medium injection, the quality, intensity, and distribution of the resultant pain produced were recorded. Of the 21 costotransverse joint injections, 16 (76%) were classified as being intra-articular via arthrograms taken at the time of injection, and 14 of these injections produced a pain sensation distinctly different from that of needle placement. Average pain produced was 3.3/10 on a 0-10 verbal pain scale. Pain was described generally as a deep, dull ache, and pressure sensation. Pain patterns were located superficial to the injected joint, with only the right T2 injections showing referred pain 2 segments cranially and caudally. No chest wall, upper extremity or pseudovisceral pains were reported. This study provides preliminary data of the pain referral patterns of costotransverse joints. Further research is needed to compare these findings with those elicited from symptomatic subjects.

  17. Statistical Investigation of the Effect of Process Parameters on the Shear Strength of Metal Adhesive Joints

    NASA Astrophysics Data System (ADS)

    Rajkumar, Goribidanur Rangappa; Krishna, Munishamaih; Narasimhamurthy, Hebbale Narayanrao; Keshavamurthy, Yalanabhalli Channegowda

    2017-06-01

    The objective of the work was to optimize sheet metal joining parameters such as adhesive material, adhesive thickness, adhesive overlap length and surface roughness for single lap joint of aluminium sheet shear strength using robust design. An orthogonal array, main effect plot, signal-to-noise ratio and analysis of variance were employed to investigate the shear strength of the joints. The statistical result shows vinyl ester is best candidate among other two polymers viz. epoxy and polyester due to its low viscosity value compared to other two polymers. The experiment results shows that the adhesive thickness 0.6 mm, overlap length 50 mm and surface roughness 2.12 µm for obtained maximum shear strength of Al sheet joints. The ANOVA result shows one of the most significant factors is overlap length which affect joint strength in addition to adhesive thickness, adhesive material, and surface roughness. A confirmation test was carried out as the optimal combination of parameters will not match with the any of the experiments in the orthogonal array.

  18. The effect of sacroiliac joint mobilization on pelvic deformation and the static balance ability of female university students with si joint dysfunction.

    PubMed

    Son, Jeong-Hyun; Park, Gi Duck; Park, Hoo Sung

    2014-06-01

    [Purpose] The present study aimed to determine the effect of an 8-week program of joint mobilization on changes in pelvic obliquity and pain level in seventeen female university students aged in their 20's with sacroiliac joint dysfunction by dividing them into two groups: a joint mobilization group (MWM) and a control group. [Subjects] Seventeen subjects were selected from female university students aged in their 20's attending N University in Cheon-An City, Korea, The subjects had sacroiliac joint syndrome, but experienced no problems with daily living and had no previous experience of joint mobilization exercise. The subjects were randomly assigned to a joint mobilization group of eight and a control group of nine who performed joint mobilization exercise. [Methods] Body fat and lean body mass were measured using InBody 7.0 (Biospace, Korea). The Direct Segmental Multi-frequency Bioelectrical Impedance Analysis Method (DSM-BIA) was used for body composition measurement. A pressure footstool (Pedoscan, DIERS, Germany) and a trunk measurement system (Formetric 4D, DIERS, Germany), a 3D image processing apparatus with high resolution for vertebrae, were used to measure 3D trunk images of the vertebrae and pelvis obliquity, as well as static balance ability. [Result] The MWM group showed a significantly better Balance than the control group. In addition, the results of the left/right and the front/rear balance abilities were significantly better than those of the control group. [Conclusion] This study proved that a combination of mobilization with movement and functional training was effective in reducing pelvis malposition and pain, and improving static stability control.

  19. Experimental Investigation on Friction Stir Welding of Cryorolled AA2219 Aluminum Alloy Joints

    NASA Astrophysics Data System (ADS)

    Babu, K. Kamal; Panneerselvam, K.; Sathiya, P.; Haq, A. Noorul; Sundarrajan, S.; Mastanaiah, P.; Murthy, C. V. Srinivasa

    2017-07-01

    In this paper, experimental investigation on cryorolled aluminum AA2219-T87 plate by using friction stir welding (FSW) process is carried out. AA2219-T87 plates with a size of 200×100×22.4 mm were rolled and reduced to 12.2mm thickness (more than 45% of reduction in total thickness of the base material) at cryogenic temperature (operating temperature range -90--30∘C). The cryorolled (CR) plates have reduced grain size, improved hardness and increased corrosion resistance property compared with the uncryorolled AA2219-T87 plates. FSW joints of cryorolled AA2219-T87 plates were prepared using cylindrical threaded FSW tool pin profile. Mechanical and metallurgical behaviors of friction stir welded joints were analyzed and the effects of the FSW process parameters are discussed in this paper. The variation of microhardness in the FSW joint regions were correlated with the microstructure of FSW joints. Cryorolled plate and FSW joints were tested for corrosion resistance using potentiodynamic polarization test. FSW joints shows better result during the corrosion resistance analysis compared to base AA2219-T87. The X-ray diffraction (XRD) test results showed that fine α-Al grains with eutectic phase (Al2Cu) were present in the weld nugget (WN). The large clusters of strengthening precipitates were reduced in size and merged with the weld nugget portion.

  20. Simulation and Experiment Research on Fatigue Life of High Pressure Air Pipeline Joint

    NASA Astrophysics Data System (ADS)

    Shang, Jin; Xie, Jianghui; Yu, Jian; Zhang, Deman

    2017-12-01

    High pressure air pipeline joint is important part of high pressure air system, whose reliability is related to the safety and stability of the system. This thesis developed a new type-high pressure air pipeline joint, carried out dynamics research on CB316-1995 and new type-high pressure air pipeline joint with finite element method, deeply analysed the join forms of different design schemes and effect of materials on stress, tightening torque and fatigue life of joint. Research team set up vibration/pulse test bench, carried out joint fatigue life contrast test. The result shows: the maximum stress of the joint is inverted in the inner side of the outer sleeve nut, which is consistent with the failure mode of the crack on the outer sleeve nut in practice. Simulation and experiment of fatigue life and tightening torque of new type-high pressure air pipeline joint are better than CB316-1995 joint.

  1. Audit of conservative management of chronic low back pain in a secondary care setting--part I: facet joint and sacroiliac joint interventions.

    PubMed

    Chakraverty, Robin; Dias, Richard

    2004-12-01

    The work of a chronic back pain service in secondary care in the West Midlands is reported. The service offers acupuncture, spinal injection procedures, osteopathy and a range of other interventions for patients whose back pain has not responded to conservative management. This section of the report focuses on injection procedures for lumbar facet joint and sacroiliac joint pain, which have been shown to be the cause of chronic low back pain in 16-40% and 13-19% of patients respectively. Diagnosis relies on the use of intra-articular or sensory nerve block injections with local anaesthetic. Possible treatments following diagnosis include intra-articular corticosteroid, radiofrequency denervation (for facet joint pain) or ligament prolotherapy injections (for sacroiliac joint pain). The results of several hospital audits are reported. At six month follow up, 50% of 38 patients undergoing radiofrequency denervation following diagnostic blocks for facet joint pain had improved by more than 50%, compared to 29% of 34 patients treated with intra-articular corticosteroid injection. Sixty three per cent of 19 patients undergoing prolotherapy following diagnostic block injection for sacroiliac joint pain had improved at six months, compared to 33% of 33 who had intra-articular corticosteroid. Both radiofrequency denervation and sacroiliac prolotherapy showed good long-term outcomes at one year.

  2. Joint Contact Stress

    PubMed Central

    Brand, Richard A

    2005-01-01

    A joint's normal mechanical history contributes to the maintenance of articular cartilage and underlying bone. Loading facilitates the flow of nutrients into cartilage and waste products away, and additionally provides the mechanical signals essential for normal cell and tissue maintenance. Deleteriously low or high contact stresses have been presumed to result in joint deterioration, and particular aspects of the mechanical environment may facilitate repair of damaged cartilage. For decades, investigators have explored static joint contact stresses (under some more or less arbitrary condition) as a surrogate of the relevant mechanical history. Contact stresses have been estimated in vitro in many joints and in a number of species, although only rarely in vivo. Despite a number of widely varying techniques (and spatial resolutions) to measure these contact stresses, reported ranges of static peak normal stresses are relatively similar from joint to joint across species, and in the range of 0.5 to 5.0 MPa. This suggests vertebrate diarthrodial joints have evolved to achieve similar mechanical design criteria. Available evidence also suggests some disorders of cartilage deterioration are associated with somewhat higher peak pressures ranging from 1-20 MPa, but overlapping the range of normal pressures. Some evidence and considerable logic suggests static contact stresses per se do not predict cartilage responses, but rather temporal aspects of the contact stress history. Static contact stresses may therefore not be a reasonable surrogate for biomechanical studies. Rather, temporal and spatial aspects of the loading history undoubtedly induce beneficial and deleterious biological responses. Finally, since all articular cartilage experiences similar stresses, the concept of a "weight-bearing" versus a "non-weight-bearing" joint seems flawed, and should be abandoned. PMID:16089079

  3. Deformations and strains in adhesive joints by moire interferometry

    NASA Technical Reports Server (NTRS)

    Post, D.; Czarnek, R.; Wood, J.; John, D.; Lubowinski, S.

    1984-01-01

    Displacement fields in a thick adherend lap joint and a cracked lap shear specimen were measured by high sensitivity moire interferometry. Contour maps of in-plane U and V displacements were obtained across adhesive and adherent surfaces. Loading sequences ranged from modest loads to near-failure loads. Quantitative results are given for displacements and certain strains in the adhesive and along the adhesive/adherend boundary lines. The results show nonlinear displacements and strains as a function of loads or stresses and they show viscoelastic or time-dependent response. Moire interferometry is an excellent method for experimental studies of adhesive joint performance. Subwavelength displacement resolution of a few micro-inches, and spatial resolution corresponding to 1600 fringes/inch (64 fringes/mm), were obtained in these studies. The whole-field contour maps offer insights not available from local measurements made by high sensitivity gages.

  4. Hip and knee joints are more stabilized than driven during the stance phase of gait: an analysis of the 3D angle between joint moment and joint angular velocity.

    PubMed

    Dumas, R; Cheze, L

    2008-08-01

    Joint power is commonly used in orthopaedics, ergonomics or sports analysis but its clinical interpretation remains controversial. Some basic principles on muscle actions and energy transfer have been proposed in 2D. The decomposition of power on 3 axes, although questionable, allows the same analysis in 3D. However, these basic principles have been widely criticized, mainly because bi-articular muscles must be considered. This requires a more complex computation in order to determine how the individual muscle force contributes to drive the joint. Conversely, with simple 3D inverse dynamics, the analysis of both joint moment and angular velocity directions is essential to clarify when the joint moment can contribute or not to drive the joint. The present study evaluates the 3D angle between the joint moment and the joint angular velocity and investigates when the hip, knee and ankle joints are predominantly driven (angle close to 0 degrees and 180 degrees ) or stabilized (angle close to 90 degrees ) during gait. The 3D angle curves show that the three joints are never fully but only partially driven and that the hip and knee joints are mainly stabilized during the stance phase. The notion of stabilization should be further investigated, especially for subjects with motion disorders or prostheses.

  5. Numerical simulation of artificial hip joint motion based on human age factor

    NASA Astrophysics Data System (ADS)

    Ramdhani, Safarudin; Saputra, Eko; Jamari, J.

    2018-05-01

    Artificial hip joint is a prosthesis (synthetic body part) which usually consists of two or more components. Replacement of the hip joint due to the occurrence of arthritis, ordinarily patients aged or older. Numerical simulation models are used to observe the range of motion in the artificial hip joint, the range of motion of joints used as the basis of human age. Finite- element analysis (FEA) is used to calculate stress von mises in motion and observes a probability of prosthetic impingement. FEA uses a three-dimensional nonlinear model and considers the position variation of acetabular liner cups. The result of numerical simulation shows that FEA method can be used to analyze the performance calculation of the artificial hip joint at this time more accurate than conventional method.

  6. Joint modeling of longitudinal data and discrete-time survival outcome.

    PubMed

    Qiu, Feiyou; Stein, Catherine M; Elston, Robert C

    2016-08-01

    A predictive joint shared parameter model is proposed for discrete time-to-event and longitudinal data. A discrete survival model with frailty and a generalized linear mixed model for the longitudinal data are joined to predict the probability of events. This joint model focuses on predicting discrete time-to-event outcome, taking advantage of repeated measurements. We show that the probability of an event in a time window can be more precisely predicted by incorporating the longitudinal measurements. The model was investigated by comparison with a two-step model and a discrete-time survival model. Results from both a study on the occurrence of tuberculosis and simulated data show that the joint model is superior to the other models in discrimination ability, especially as the latent variables related to both survival times and the longitudinal measurements depart from 0. © The Author(s) 2013.

  7. Shoulder and Lower Back Joint Reaction Forces in Seated Double Poling.

    PubMed

    Lund Ohlsson, Marie; Danvind, Jonas; Holmberg, L Joakim

    2018-04-13

    Overuse injuries in the shoulders and lower back are hypothesized to be common in cross-country sit-skiing. Athletes with reduced trunk muscle control mainly sits with their knees higher than hips (KH). To reduce spinal flexion, a position with the knees below the hips (KL) was enabled for these athletes using a frontal trunk support. The aim of the study was to compare the shoulder joint (glenohumeral joint) and L4-L5 joint reactions between the sitting positions KL and KH. Five able-bodied female athletes performed submaximal and maximal exercise tests in the sitting positions KL and KH on a ski-ergometer. Measured pole forces and 3-dimensional kinematics served as input for inverse-dynamics simulations to compute the muscle forces and joint reactions in the shoulder and L4-L5 joint. This was the first musculoskeletal simulation study of seated double poling. The results showed that the KH position was favorable for higher performance and decreased values of the shoulder joint reactions for female able-bodied athletes with full trunk control. The KL position was favorable for lower L4-L5 joint reactions and might therefore reduce the risk of lower back injuries. These results indicate that it is hard to optimize both performance and safety in the same sit-ski.

  8. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Joint facilities. 154.307 Section 154.307 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment...

  9. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Joint facilities. 154.307 Section 154.307 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment...

  10. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Joint facilities. 154.307 Section 154.307 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment...

  11. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Joint facilities. 154.307 Section 154.307 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment...

  12. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Joint facilities. 154.307 Section 154.307 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment...

  13. High pressure ceramic joint

    DOEpatents

    Ward, Michael E.; Harkins, Bruce D.

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  14. Stress analyses for the glass joints of contemporary sodium sulfur batteries

    NASA Astrophysics Data System (ADS)

    Jung, Keeyoung; Lee, Solki; Kim, Goun; Kim, Chang-Soo

    2014-12-01

    During the manufacturing and thermal cycles of advanced contemporary large sized sodium sulfur (NaS) batteries, thermally driven stresses can be applied to the glass sealing joints, which may result in catastrophic cell failure. To minimize the thermal stresses at the joints, there is a need to develop a method to properly estimate the maximum thermal stresses by varying the materials properties and shapes of the sealing area, and thereby determine the properties and shapes of sealing material at the joints. In the present study, the optimum coefficient of thermal expansion (CTE) of the glass sealant and end shape of the glass sealing area (i.e., concave, flat, and convex shapes) have been determined using the finite-element analysis (FEA) computation technique. The results showed that the CTE value of 7.8 × 10-6 K-1 with a convex end shape would have the lowest stress concentration in the vicinity of glass sealing joints for the prototype tubular NaS cell design adopted in this work.

  15. Seal Joint Analysis and Design for the Ares-I Upper Stage LOX Tank

    NASA Technical Reports Server (NTRS)

    Phillips, Dawn R.; Wingate, Robert J.

    2011-01-01

    The sealing capability of the Ares-I Upper Stage liquid oxygen tank-to-sump joint is assessed by analyzing the deflections of the joint components. Analyses are performed using three-dimensional symmetric wedge finite element models and the ABAQUS commercial finite element software. For the pressure loads and feedline interface loads, the analyses employ a mixed factor of safety approach to comply with the Constellation Program factor of safety requirements. Naflex pressure-assisted seals are considered first because they have been used successfully in similar seal joints in the Space Shuttle External Tank. For the baseline sump seal joint configuration with a Naflex seal, the predicted joint opening greatly exceeds the seal design specification. Three redesign options of the joint that maintain the use of a Naflex seal are studied. The joint openings for the redesigned seal joints show improvement over the baseline configuration; however, these joint openings still exceed the seal design specification. RACO pressure-assisted seals are considered next because they are known to also be used on the Space Shuttle External Tank, and the joint opening allowable is much larger than the specification for the Naflex seals. The finite element models for the RACO seal analyses are created by modifying the models that were used for the Naflex seal analyses. The analyses show that the RACO seal may provide sufficient sealing capability for the sump seal joint. The results provide reasonable data to recommend the design change and plan a testing program to determine the capability of RACO seals in the Ares-I Upper Stage liquid oxygen tank sump seal joint.

  16. Translational and rotational knee joint stability in anterior and posterior cruciate-retaining knee arthroplasty.

    PubMed

    Lo, JiaHsuan; Müller, Otto; Dilger, Torsten; Wülker, Nikolaus; Wünschel, Markus

    2011-12-01

    This study investigated passive translational and rotational stability properties of the intact knee joint, after bicruciate-retaining bi-compartmental knee arthroplasty (BKA) and after posterior cruciate retaining total knee arthroplasty (TKA). Fourteen human cadaveric knee specimens were used in this study, and a robotic manipulator with six-axis force/torque sensor was used to test the joint laxity in anterior-posterior translation, valgus-varus, and internal-external rotation. The results show the knee joint stability after bicruciate-retaining BKA is similar to that of the native knee. On the other hand, the PCL-retaining TKA results in inferior joint stability in valgus, varus, external rotation, anterior and, surprisingly, posterior directions. Our findings suggest that, provided functional ligamentous structures, bicruciate-retaining BKA is a biomechanically attractive treatment for joint degenerative disease. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Single strip lesions radiofrequency denervation for treatment of sacroiliac joint pain: two years' results.

    PubMed

    Bellini, Martina; Barbieri, Massimo

    2016-01-01

    Sacroiliac joint pain can be managed by intra-articular injections or radiofrequency of its innervation. Single strip lesions radiofrequency denervation is a new system. The objective of this study was to present one of the first utilizations of this innovative technique. 60 patients who met the diagnostic criteria for sacroiliac joint syndrome were enrolled in the study. In total, 102 single strip lesions radiofrequency denervations were performed. Pain intensity was measured with the Oswestry low back pain disability questionnaire and the Oswestry Disability Index whose scores were assessed at 1, 3, 6 and 12 months after the procedure. 91.8 % of the 102 radiofrequency treatments resulted in a reduction of more than 50% pain intensity relief at 1 month, 81.6% at 3 months and 59.16% at 6 months. In 35.7% of cases, the relief was continuative up to 1 year. No relief was observed in 12.24% of cases. The ODI scores improved significantly 1 month after the procedure, compared with the baseline scores. The ODI scores after 6 months improved very clearly compared with the baseline scores and with the 3-month scores. Single strip lesions radiofrequency denervation using the Simplicity III probe is a potential modality for intermediate term relief for patients with sacroiliac pain.

  18. A critical examination of stresses in an elastic single lap joint

    NASA Technical Reports Server (NTRS)

    Cooper, P. A.; Sawyer, J. W.

    1979-01-01

    The results of an approximate nonlinear finite-element analysis of a single lap joint are presented and compared with the results of a linear finite-element analysis, and the geometric nonlinear effects caused by the load-path eccentricity on the adhesive stress distributions are determined. The results from finite-element, Goland-Reissner, and photoelastic analyses show that for a single lap joint the effect of the geometric nonlinear behavior of the joint has a sizable effect on the stresses in the adhesive. The Goland-Reissner analysis is sufficiently accurate in the prediction of stresses along the midsurface of the adhesive bond to be used for qualitative evaluation of the influence of geometric or material parametric variations. Detailed stress distributions in both the adherend and adhesive obtained from the finite-element analysis are presented to provide a basis for comparison with other solution techniques.

  19. Gait analysis and weight bearing in pre-clinical joint pain research.

    PubMed

    Ängeby Möller, Kristina; Svärd, Heta; Suominen, Anni; Immonen, Jarmo; Holappa, Johanna; Stenfors, Carina

    2018-04-15

    There is a need for better joint pain treatment, but development of new medication has not been successful. Pre-clinical models with readouts that better reflect the clinical situation are needed. In patients with joint pain, pain at rest and pain at walking are two major complaints. We describe a new way of calculating results from gait analysis using the CatWalk™ setup. Rats with monoarthritis induced by injection of Complete Freund's Adjuvant (CFA) intra-articularly into the ankle joint of one hind limb were used to assess gait and dynamic weight bearing. The results show that dynamic weight bearing was markedly reduced for the injected paw. Gait parameters such as amount of normal step sequences, walking speed and duration of step placement were also affected. Treatment with naproxen (an NSAID commonly used for inflammatory pain) attenuated the CFA-induced effects. Pregabalin, which is used for neuropathic pain, had no effect. Reduced dynamic weight bearing during locomotion, assessed and calculated in the way we present here, showed a dose-dependent and lasting normalization after naproxen treatment. In contrast, static weight bearing while standing (Incapacitance tester) showed a significant effect for a limited time only. Mechanical sensitivity (von Frey Optihairs) was completely normalized by naproxen, and the window for testing pharmacological effect disappeared. Objective and reproducible effects, with an endpoint showing face validity compared to pain while walking in patients with joint pain, are achieved by a new way of calculating dynamic weight bearing in monoarthritic rats. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Modeling joint restoration strategies for interdependent infrastructure systems

    PubMed Central

    Simonovic, Slobodan P.

    2018-01-01

    Life in the modern world depends on multiple critical services provided by infrastructure systems which are interdependent at multiple levels. To effectively respond to infrastructure failures, this paper proposes a model for developing optimal joint restoration strategy for interdependent infrastructure systems following a disruptive event. First, models for (i) describing structure of interdependent infrastructure system and (ii) their interaction process, are presented. Both models are considering the failure types, infrastructure operating rules and interdependencies among systems. Second, an optimization model for determining an optimal joint restoration strategy at infrastructure component level by minimizing the economic loss from the infrastructure failures, is proposed. The utility of the model is illustrated using a case study of electric-water systems. Results show that a small number of failed infrastructure components can trigger high level failures in interdependent systems; the optimal joint restoration strategy varies with failure occurrence time. The proposed models can help decision makers to understand the mechanisms of infrastructure interactions and search for optimal joint restoration strategy, which can significantly enhance safety of infrastructure systems. PMID:29649300

  1. Modeling joint restoration strategies for interdependent infrastructure systems.

    PubMed

    Zhang, Chao; Kong, Jingjing; Simonovic, Slobodan P

    2018-01-01

    Life in the modern world depends on multiple critical services provided by infrastructure systems which are interdependent at multiple levels. To effectively respond to infrastructure failures, this paper proposes a model for developing optimal joint restoration strategy for interdependent infrastructure systems following a disruptive event. First, models for (i) describing structure of interdependent infrastructure system and (ii) their interaction process, are presented. Both models are considering the failure types, infrastructure operating rules and interdependencies among systems. Second, an optimization model for determining an optimal joint restoration strategy at infrastructure component level by minimizing the economic loss from the infrastructure failures, is proposed. The utility of the model is illustrated using a case study of electric-water systems. Results show that a small number of failed infrastructure components can trigger high level failures in interdependent systems; the optimal joint restoration strategy varies with failure occurrence time. The proposed models can help decision makers to understand the mechanisms of infrastructure interactions and search for optimal joint restoration strategy, which can significantly enhance safety of infrastructure systems.

  2. Multipacting in a grooved choke joint at SRF gun for BNL ERL prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, W.; Ben-Zvi, I.; Belomestnykh, S.

    2011-03-28

    The 703 MHz superconducting gun for BNL ERL prototype was tested at JLab with and without choke-joint and cathode stalk. Without choke-joint and cathode stalk, the gradient reached was 25 MV/m with Q{sup 0} {approx} 6E9. The gun cathode insertion port is equipped with a grooved choke joint for multipacting suppression. We carried out tests with choke-joint and cathode stalk. The test results show that there are at least two barriers at about 3.5 MV/m and 5 MV/m. We considered several possibilities and finally found that fine details of the grooved shape are important for multipacting suppression. A triangular groovemore » with round crest may cause strong multipacting in the choke-joint at 3.5 MV/m, 5 MV/m and 10 MV/m. This paper presents the primary test results of the gun and discusses the multipacting analysis in the choke-joint. It also suggests possible solutions for the gun and multipacting suppressing for a similar structure.« less

  3. Expose : procedure and results of the joint experiment verification tests

    NASA Astrophysics Data System (ADS)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  4. Estimation of ground reaction forces and joint moments on the basis on plantar pressure insoles and wearable sensors for joint angle measurement.

    PubMed

    Ostaszewski, Michal; Pauk, Jolanta

    2018-05-16

    Gait analysis is a useful tool medical staff use to support clinical decision making. There is still an urgent need to develop low-cost and unobtrusive mobile health monitoring systems. The goal of this study was twofold. Firstly, a wearable sensor system composed of plantar pressure insoles and wearable sensors for joint angle measurement was developed. Secondly, the accuracy of the system in the measurement of ground reaction forces and joint moments was examined. The measurements included joint angles and plantar pressure distribution. To validate the wearable sensor system and examine the effectiveness of the proposed method for gait analysis, an experimental study on ten volunteer subjects was conducted. The accuracy of measurement of ground reaction forces and joint moments was validated against the results obtained from a reference motion capture system. Ground reaction forces and joint moments measured by the wearable sensor system showed a root mean square error of 1% for min. GRF and 27.3% for knee extension moment. The correlation coefficient was over 0.9, in comparison with the stationary motion capture system. The study suggests that the wearable sensor system could be recommended both for research and clinical applications outside a typical gait laboratory.

  5. Quantitative three-dimensional photoacoustic tomography of the finger joints: an in vivo study

    NASA Astrophysics Data System (ADS)

    Sun, Yao; Sobel, Eric; Jiang, Huabei

    2009-11-01

    We present for the first time in vivo full three-dimensional (3-D) photoacoustic tomography (PAT) of the distal interphalangeal joint in a human subject. Both absorbed energy density and absorption coefficient images of the joint are quantitatively obtained using our finite-element-based photoacoustic image reconstruction algorithm coupled with the photon diffusion equation. The results show that major anatomical features in the joint along with the side arteries can be imaged with a 1-MHz transducer in a spherical scanning geometry. In addition, the cartilages associated with the joint can be quantitatively differentiated from the phalanx. This in vivo study suggests that the 3-D PAT method described has the potential to be used for early diagnosis of joint diseases such as osteoarthritis and rheumatoid arthritis.

  6. Influence of the implant-abutment connection design and diameter on the screw joint stability.

    PubMed

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo

    2014-04-01

    This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

  7. Biomechanical Effects of Stiffness in Parallel With the Knee Joint During Walking.

    PubMed

    Shamaei, Kamran; Cenciarini, Massimo; Adams, Albert A; Gregorczyk, Karen N; Schiffman, Jeffrey M; Dollar, Aaron M

    2015-10-01

    The human knee behaves similarly to a linear torsional spring during the stance phase of walking with a stiffness referred to as the knee quasi-stiffness. The spring-like behavior of the knee joint led us to hypothesize that we might partially replace the knee joint contribution during stance by utilizing an external spring acting in parallel with the knee joint. We investigated the validity of this hypothesis using a pair of experimental robotic knee exoskeletons that provided an external stiffness in parallel with the knee joints in the stance phase. We conducted a series of experiments involving walking with the exoskeletons with four levels of stiffness, including 0%, 33%, 66%, and 100% of the estimated human knee quasi-stiffness, and a pair of joint-less replicas. The results indicated that the ankle and hip joints tend to retain relatively invariant moment and angle patterns under the effects of the exoskeleton mass, articulation, and stiffness. The results also showed that the knee joint responds in a way such that the moment and quasi-stiffness of the knee complex (knee joint and exoskeleton) remains mostly invariant. A careful analysis of the knee moment profile indicated that the knee moment could fully adapt to the assistive moment; whereas, the knee quasi-stiffness fully adapts to values of the assistive stiffness only up to ∼80%. Above this value, we found biarticular consequences emerge at the hip joint.

  8. Reduced-order modeling approach for frictional stick-slip behaviors of joint interface

    NASA Astrophysics Data System (ADS)

    Wang, Dong; Xu, Chao; Fan, Xuanhua; Wan, Qiang

    2018-03-01

    The complex frictional stick-slip behaviors of mechanical joint interface have a great effect on the dynamic properties of assembled structures. In this paper, a reduced-order modeling approach based on the constitutive Iwan model is proposed to describe the stick-slip behaviors of joint interface. An improved Iwan model is developed to describe the non-zero residual stiffness at macro-slip regime and smooth transition of joint stiffness from micro-slip to macro-slip regime, and the power-law relationship of energy dissipation during the micro-slip regime. In allusion to these nonlinear behaviors, the finite element method is used to calculate the recycle force under monolithic loading and the energy dissipation per cycle under oscillatory loading. The proposed model is then used to predict the nonlinear stick-slip behaviors of joint interface by curve-fitting to the results of finite element analysis, and the results show good agreements with the finite element analysis. A comparison with the experiment results in literature is also made. The proposed model agrees very well with the experiment results.

  9. Immediate effects of different treatments for the wrist joints of subdominant hands, using electromechanical reaction time.

    PubMed

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Zhou, Yue; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-08-01

    [Purpose] The aim of this study was to examine the immediate effects of muscle strength training and neuromuscular joint facilitation distal resistance training on wrist joints by using electromechanical reaction time. [Subjects and Methods] The subjects were 12 healthy young people (24.2 ± 3.1 years, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two kinds of isotonic contraction techniques were applied on the wrist joint: the wrist joint extension muscle strength training and the wrist joint extension pattern of neuromuscular joint facilitation. The electromechanical reaction time, premotor time, and motor time of the left upper limb were measured before and after each intervention session of muscle strength training and neuromuscular joint facilitation. [Results] The neuromuscular joint facilitation group showed significant shortening of the electromechanical reaction time and motor time after the intervention. [Conclusion] These results suggest that the electromechanical reaction time and motor time of the wrist joint can be improved by neuromuscular joint facilitation together with proximal resistance training, which can be used as a new form of exercise for improving the functions of subdominant hand wrist joints.

  10. Spatial and temporal modulation of joint stiffness during multijoint movement.

    PubMed

    Mah, C D

    2001-02-01

    Joint stiffness measurements during small transient perturbations have suggested that stiffness during movement is different from that observed during posture. These observations are problematic for theories like the classical equilibrium point hypothesis, which suggest that desired trajectories during movement are enforced by joint stiffness. We measured arm impedances during large, slow perturbations to obtain detailed information about the spatial and temporal modulation of stiffness and viscosity during movement. While our measurements of stiffness magnitudes during movement generally agreed with the results of measurements using fast perturbations, they revealed that joint stiffness undergoes stereotyped changes in magnitude and aspect ratio which depend on the direction of movement and show a strong dependence on joint angles. Movement simulations using measured parameters show that the measured modulation of impedance acts as an energy conserving force field to constrain movement. This mechanism allows for a computationally simplified account of the execution of multijoint movement. While our measurements do not rule out a role for afferent feedback in force generation, the observed stereotyped restoring forces can allow a dramatic relaxation of the accuracy requirements for forces generated by other control mechanisms, such as inverse dynamical models.

  11. The surface geometry of inherited joint and fracture trace patterns resulting from active and passive deformation

    NASA Technical Reports Server (NTRS)

    Podwysocki, M. H.; Gold, D. P.

    1974-01-01

    Hypothetical models are considered for detecting subsurface structure from the fracture or joint pattern, which may be influenced by the structure and propagated to the surface. Various patterns of an initially orthogonal fracture grid are modeled according to active and passive deformation mechanisms. In the active periclinal structure with a vertical axis, fracture frequency increased both over the dome and basin, and remained constant with decreasing depth to the structure. For passive periclinal features such as a reef or sand body, fracture frequency is determined by the arc of curvature and showed a reduction over the reefmound and increased over the basin.

  12. A novel multi-item joint replenishment problem considering multiple type discounts.

    PubMed

    Cui, Ligang; Zhang, Yajun; Deng, Jie; Xu, Maozeng

    2018-01-01

    In business replenishment, discount offers of multi-item may either provide different discount schedules with a single discount type, or provide schedules with multiple discount types. The paper investigates the joint effects of multiple discount schemes on the decisions of multi-item joint replenishment. In this paper, a joint replenishment problem (JRP) model, considering three discount (all-unit discount, incremental discount, total volume discount) offers simultaneously, is constructed to determine the basic cycle time and joint replenishment frequencies of multi-item. To solve the proposed problem, a heuristic algorithm is proposed to find the optimal solutions and the corresponding total cost of the JRP model. Numerical experiment is performed to test the algorithm and the computational results of JRPs under different discount combinations show different significance in the replenishment cost reduction.

  13. Field homogeneity improvement of maglev NdFeB magnetic rails from joints.

    PubMed

    Li, Y J; Dai, Q; Deng, C Y; Sun, R X; Zheng, J; Chen, Z; Sun, Y; Wang, H; Yuan, Z D; Fang, C; Deng, Z G

    2016-01-01

    An ideal magnetic rail should provide a homogeneous magnetic field along the longitudinal direction to guarantee the reliable friction-free operation of high temperature superconducting (HTS) maglev vehicles. But in reality, magnetic field inhomogeneity may occur due to lots of reasons; the joint gap is the most direct one. Joint gaps inevitably exist between adjacent segments and influence the longitudinal magnetic field homogeneity above the rail since any magnetic rails are consisting of many permanent magnet segments. To improve the running performance of maglev systems, two new rail joints are proposed based on the normal rail joint, which are named as mitered rail joint and overlapped rail joint. It is found that the overlapped rail joint has a better effect to provide a competitive homogeneous magnetic field. And the further structure optimization has been done to ensure maglev vehicle operation as stable as possible when passing through those joint gaps. The results show that the overlapped rail joint with optimal parameters can significantly reduce the magnetic field inhomogeneity comparing with the other two rail joints. In addition, an appropriate gap was suggested when balancing the thermal expansion of magnets and homogenous magnetic field, which is considered valuable references for the future design of the magnetic rails.

  14. 14. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF INADEQUATE TAMPING. THE SIZE OF THE GRANITE AGGREGATE USED IN THE DAMS CONCRETE IS CLEARLY SHOWN. - Hume Lake Dam, Sequioa National Forest, Hume, Fresno County, CA

  15. Safety assessment of Cracked K-joint Structure Based on Fracture Mechanics

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Pengyu, Yan; Jianwei, Du; Fuhai, Cai

    2017-05-01

    The K-joint is the main bearing structure of lattice jib crane. During frequent operation of the crane, surface cracks often occur at its weld toe, and then continue to expand until failure. The safety of the weak structure K-joint of the crane jib can be evaluated by BS7910 failure assessment standard in order to improve its utilization. The finite element model of K-joint structure with cracks is established, and its mechanical properties is analyzed by ABAQUS software, the results show that the crack depth has a great influence on the bearing capacity of the structure compared with the crack length. It is assumed that the K-joint with the semi-elliptical surface crack under the action of the tension propagate stably under the condition that the c/a (ratio of short axis to long axis of ellipse) is about 0.3. The safety assessment of K-joint with different lengths crack is presented according to the 2A failure assessment diagram of BS7910, and the critical crack of K-joint under different loads can be obtained.

  16. Joint Manipulation: Toward a General Theory of High-Velocity, Low-Amplitude Thrust Techniques.

    PubMed

    Harwich, Andrew S

    2017-12-01

    The objective of this study was to describe the initial stage of a generalized theory of high-velocity, low-amplitude thrust (HVLAT) techniques for joint manipulation. This study examined the movements described by authors from the fields of osteopathy, chiropractic, and physical therapy to produce joint cavitation in both the metacarpophalangeal (MCP) joint and the cervical spine apophysial joint. This study qualitatively compared the kinetics, the similarities, and the differences between MCP cavitation and cervical facet joint cavitation. A qualitative vector analysis of forces and movements was undertaken by constructing computer-generated, simplified graphical models of the MCP joint and a typical cervical apophysial joint and imposing the motions dictated by the clinical technique. Comparing the path to cavitation of 2 modes of HVLAT for the MCP joint, namely, distraction and hyperflexion, it was found that the hyperflexion method requires an axis of rotation, the hinge axis, which is also required for cervical HVLAT. These results show that there is an analogue of cervical HVLAT in one of the MCP joint HVLATs. The study demonstrated that in a theoretical model, the path to joint cavitation is the same for asymmetric separation of the joint surfaces in the cervical spine and the MCP joints.

  17. [Effects of exercise on joints.

    PubMed

    Moriyama, Hideki

    Joints are composed of several different tissues(cartilage, capsule, meniscus, and ligament), and articular cartilage plays an important role in maintaining mechanical competence during exercise. Weight-bearing exercise has several benefit, including improved blood and synovial fluid circulation in a given joint. Consistent moderate activities facilitate cycles of anabolism and catabolism. Mechanical stresses are crucial for the maintenance of the morphologic and functional integrity of articular cartilage. Healthy cartilage is exposed by hydrostatic pressure and tensile strain, when cartilage degeneration develops, abnormal cartilage is exposed by shear stress. Moderate(physiological)exercise is characterized by a range of equilibrium between matrix anabolic and catabolic processes, or anabolism beyond catabolism. Joints are susceptible to insufficient or excessive activities, leading to joint degeneration. Lack of exercise is known to induce joint contracture seen clinically as a consequence of disuse changes, and excess mechanical stresses induce joint destruction such as osteoarthritis. Joint diseases resulting from insufficient or excessive activities are new and major challenging issues with our aging population. Thus, it is highly desirable to have an effective and efficient treatment to improve and protect against these joint diseases, and thereby to solve these clearly unanswered issues.

  18. Clinical synovitis in a particular joint is associated with progression of erosions and joint space narrowing in that same joint, but not in patients initially treated with infliximab.

    PubMed

    Klarenbeek, N B; Güler-Yüksel, M; van der Heijde, D M F M; Hulsmans, H M J; Kerstens, P J S M; Molenaar, T H E; de Sonnaville, P B J; Huizinga, T W J; Dijkmans, B A C; Allaart, C F

    2010-12-01

    To assess the relationship between joint tenderness, swelling and joint damage progression in individual joints and to evaluate the influence of treatment on these relationships. First-year data of the Behandel Strategieën (BeSt) study were used, in which patients recently diagnosed as having rheumatoid arthritis (RA) were randomly assigned into four different treatment strategies. Baseline and 1-year x-rays of the hands and feet were assessed using the Sharp-van der Heijde score (SHS). With generalised estimating equations, 3-monthly assessments of tender and swollen joints of year 1 were related to erosion progression, joint space narrowing (JSN) progression and total SHS progression at the individual joint level (definition > 0.5 SHS units) in year 1, corrected for potential confounders and within-patient correlation for multiple joints per patient. During year 1, 59% of all 13 959 joints analysed were ever tender and 45% ever swollen, 2.1% showed erosion progression, 1.9% JSN progression and 3.6% SHS progression. Swelling and tenderness were both independently associated with erosion and JSN progression with comparable OR, although with higher OR in the hands than in the feet. Local swelling and tenderness were not associated with local damage progression in patients initially treated with infliximab. Clinical signs of synovitis are associated with erosion and JSN progression in individual joints after 1 year in RA. A disconnect between synovitis and joint damage progression was observed at joint level in patients who were treated with methotrexate and infliximab as initial treatment, confirming the disconnect between synovitis and the development of joint damage in tumour necrosis factor blockers seen at patient level.

  19. Evaluation of effects of different treatments for the wrist joints of subdominant hands using joint proprioception and writing time.

    PubMed

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Hu, Yue; Rongming, Xia; Li, Zhou; Xiaojiao, Fu; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-05-01

    [Purpose] The purpose of this study was to examine immediate effects of strength training and NJF distal resistance training in wrist joints by using writing time and evaluation of proprioception using the JPE test. [Subjects and Methods] The subjects were 12 young healthy people (24.2 ± 3.1 y, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two isotonic contraction techniques were applied on the wrist joint: wrist joint extension muscle strength training (MST) and the wrist joint extension pattern of NJF. The uppercase English alphabet writing time and joint position errors of the left upper limb were measured before and after one intervention session of MST and NJF. [Results] The decrease in errors in wrist extension angle repetition and the writing time represented the improvement resulting from NJF. [Conclusion] This result suggests that the subdominant hands wrist joint proprioception and writing function can be improved by NJF together with proximal resistance training.

  20. All joint moments significantly contribute to trunk angular acceleration

    PubMed Central

    Nott, Cameron R.; Zajac, Felix E.; Neptune, Richard R.; Kautz, Steven A.

    2010-01-01

    Computationally advanced biomechanical analyses of gait demonstrate the often counter intuitive roles of joint moments on various aspects of gait such as propulsion, swing initiation, and balance. Each joint moment can produce linear and angular acceleration of all body segments (including those on which the moment does not directly act) due to the dynamic coupling inherent in the interconnected musculoskeletal system. This study presents the quantitative relationships between individual joint moments and trunk control with respect to balance during gait to show that the ankle, knee, and hip joint moments all affect the angular acceleration of the trunk. We show that trunk angular acceleration is affected by all the joints in the leg with varying degrees of dependence during the gait cycle. Furthermore, it is shown that inter-planar coupling exists and a two dimensional analysis of trunk balance neglects important out-of-plane joint moments that affect trunk angular acceleration. PMID:20646711

  1. SU-E-T-171: Evaluation of the Analytical Anisotropic Algorithm in a Small Finger Joint Phantom Using Monte Carlo Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chow, J; Owrangi, A; Jiang, R

    2014-06-01

    Purpose: This study investigated the performance of the anisotropic analytical algorithm (AAA) in dose calculation in radiotherapy concerning a small finger joint. Monte Carlo simulation (EGSnrc code) was used in this dosimetric evaluation. Methods: Heterogeneous finger joint phantom containing a vertical water layer (bone joint or cartilage) sandwiched by two bones with dimension 2 × 2 × 2 cm{sup 3} was irradiated by the 6 MV photon beams (field size = 4 × 4 cm{sup 2}). The central beam axis was along the length of the bone joint and the isocenter was set to the center of the joint. Themore » joint width and beam angle were varied from 0.5–2 mm and 0°–15°, respectively. Depth doses were calculated using the AAA and DOSXYZnrc. For dosimetric comparison and normalization, dose calculations were repeated in water phantom using the same beam geometry. Results: Our AAA and Monte Carlo results showed that the AAA underestimated the joint doses by 10%–20%, and could not predict joint dose variation with changes of joint width and beam angle. The calculated bone dose enhancement for the AAA was lower than Monte Carlo and the depth of maximum dose for the phantom was smaller than that for the water phantom. From Monte Carlo results, there was a decrease of joint dose as its width increased. This reflected the smaller the joint width, the more the bone scatter contributed to the depth dose. Moreover, the joint dose was found slightly decreased with an increase of beam angle. Conclusion: The AAA could not handle variations of joint dose well with changes of joint width and beam angle based on our finger joint phantom. Monte Carlo results showed that the joint dose decreased with increase of joint width and beam angle. This dosimetry comparison should be useful to radiation staff in radiotherapy related to small bone joint.« less

  2. Finite Element Analysis of the Maximum Stress at the Joints of the Transmission Tower

    NASA Astrophysics Data System (ADS)

    Itam, Zarina; Beddu, Salmia; Liyana Mohd Kamal, Nur; Bamashmos, Khaled H.

    2016-03-01

    Transmission towers are tall structures, usually a steel lattice tower, used to support an overhead power line. Usually, transmission towers are analyzed as frame-truss systems and the members are assumed to be pin-connected without explicitly considering the effects of joints on the tower behavior. In this research, an engineering example of joint will be analyzed with the consideration of the joint detailing to investigate how it will affect the tower analysis. A static analysis using STAAD Pro was conducted to indicate the joint with the maximum stress. This joint will then be explicitly analyzed in ANSYS using the Finite Element Method. Three approaches were used in the software which are the simple plate model, bonded contact with no bolts, and beam element bolts. Results from the joint analysis show that stress values increased with joint details consideration. This proves that joints and connections play an important role in the distribution of stress within the transmission tower.

  3. Joint Angular Velocity in Spastic Gait and the Influence of Muscle-Tendon Lengthening*

    PubMed Central

    GRANATA, KEVIN P.; ABEL, MARK F.; DAMIANO, DIANE L.

    2006-01-01

    Background Joint angular velocity (the rate of flexion and extension of a joint) is related to the dynamics of muscle activation and force generation during walking. Therefore, the goal of this research was to examine the joint angular velocity in normal and spastic gait and changes resulting from muscle-tendon lengthening (recession and tenotomy) in patients who have spastic cerebral palsy. Methods The gait patterns of forty patients who had been diagnosed with spastic cerebral palsy (mean age, 8.3 years; range, 3.7 to 14.8 years) and of seventy-three age-matched, normally developing subjects were evaluated with three-dimensional motion analysis and electromyography. The patients who had cerebral palsy were evaluated before muscle-tendon lengthening and nine months after treatment. Results The gait patterns of the patients who had cerebral palsy were characterized by increased flexion of the knee in the stance phase, premature plantar flexion of the ankle, and reduced joint angular velocities compared with the patterns of the normally developing subjects. Even though muscle-tendon lengthening altered sagittal joint angles in gait, the joint angular velocities were generally unchanged at the hip and knee. Only the ankle demonstrated modified angular velocities, including reduced dorsiflexion velocity at foot-strike and improved dorsiflexion velocity through midstance, after treatment. Electromyographic changes included reduced amplitude of the gastrocnemius-soleus during the loading phase and decreased knee coactivity (the ratio of quadriceps and hamstring activation) at toe-off. Principal component analyses showed that, compared with joint-angle data, joint angular velocity was better able to discriminate between the gait patterns of the normal and cerebral palsy groups. Conclusions This study showed that muscle-tendon lengthening corrects biomechanical alignment as reflected by changes in sagittal joint angles. However, joint angular velocity and

  4. High pressure ceramic joint

    DOEpatents

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  5. The Effect of Tool Profiles on Mechanical Properties of Friction Stir Welded Al5052 T-Joints.

    PubMed

    Kim, Byeong-Jin; Bang, Hee-Seon; Bang, Han-Sur

    2018-03-01

    Al5052 T butt joints with two skins (5 mm) and one stringer (3 mm) has been successfully welded by friction stir welding (FSW). Notably, this paper has been investigated the effect of tool shape on welded formation mechanism and mechanical properties. The used shapes of tool pin are two types which are cylinder (type 1) and frustum (type 2). Dimension on two types of tool pin shape is respectively pin length of 4.7 mm and pin diameter of frustum type of top (5 mm) and bottom (3 mm). The results of experiment show that inner defects in FSWed T-joints increase significantly in accordance with traverse speed. The maximum tensile strength of welded joint fabricated using type 1 is equivalent to 85% that of the base metal, which is approximately 10% higher than that of type 2. Because welded joint of type 1 has more smoothly plastic flow in comparison with type 2. Consequently, the results show that type 1 is better appropriate for friction stir welded Al5052 T butt joints than type 2.

  6. Joint imaging in polymyalgia rheumatica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Duffy, J.D.; Wahner, H.W.; Hunder, G.G.

    1976-08-01

    Technetium pertechnetate joint scintigrams were abnormal in 24 of 25 patients with polymyalgia rheumatica, in all 16 with rheumatoid arthritis, in 4 of 13 with nonarticular rheumatism, but in none of 26 control patients. Abnormal uptake in polymyalgia patients was commonest in shoulders and was less likely to be symmetric than in patients with rheumatoid arthritis, in whom distal joint abnormalities predominated. The pattern of abnormal uptake in polymyalgia rheumatica was not different in those with biopsy-proved giant cell arteritis. Correlation between symptoms and abnormal scintigrams was 72%, and abnormal uptake was present in 81% of joints of patients havingmore » physical abnormalities. Biopsy showed lymphocytic synovitis in the knee of one patient. After treatment the number of abnormal joints declined. These findings suggest that synovitis is common in polymyalgia rheumatica, and that it may account for some or most of the symptoms in this condition.« less

  7. Performance of a rigid and a flexible adhesive in lumber joints subjected to moisture content changes

    Treesearch

    G. P. Krueger; R. F. Blomquist

    1964-01-01

    Experimental work was undertaken to investigate the extent and magnitude of deterioration that can occur in typical plywood-to-lumber glue joints subjected to stresses resulting from changes in the moisture content of the wood, and to compare the performance of a somewhat flexible or deformable adhesive to that of a rigid adhesive in these joints. Results showed that...

  8. Joint attention studies in normal and autistic children using NIRS

    NASA Astrophysics Data System (ADS)

    Chaudhary, Ujwal; Hall, Michael; Gutierrez, Anibal; Messinger, Daniel; Rey, Gustavo; Godavarty, Anuradha

    2011-03-01

    Autism is a socio-communication brain development disorder. It is marked by degeneration in the ability to respond to joint attention skill task, from as early as 12 to 18 months of age. This trait is used to distinguish autistic from nonautistic. In this study Near infrared spectroscopy (NIRS) is being applied for the first time to study the difference in activation and connectivity in the frontal cortex of typically developing (TD) and autistic children between 4-8 years of age in response to joint attention task. The optical measurements are acquired in real time from frontal cortex using Imagent (ISS Inc.) - a frequency domain based NIRS system in response to video clips which engenders a feeling of joint attention experience in the subjects. A block design consisting of 5 blocks of following sequence 30 sec joint attention clip (J), 30 sec non-joint attention clip (NJ) and 30 sec rest condition is used. Preliminary results from TD child shows difference in brain activation (in terms of oxy-hemoglobin, HbO) during joint attention interaction compared to the nonjoint interaction and rest. Similar activation study did not reveal significant differences in HbO across the stimuli in, unlike in an autistic child. Extensive studies are carried out to validate the initial observations from both brain activation as well as connectivity analysis. The result has significant implication for research in neural pathways associated with autism that can be mapped using NIRS.

  9. The Treatment of Joint Pain with Intra-articular Pulsed Radiofrequency.

    PubMed

    Schianchi, Pietro M; Sluijter, Menno E; Balogh, Susan E

    2013-09-01

    The intra-articular (IA) application of pulsed radiofrequency (PRF) for pain in small and large joints represents a recent development that has proven to be effective in many cases. We performed a retrospective study of 89 such procedures in 57 consecutive patients with chronic articular pain. The aim of this retrospective study is to evaluate the effectiveness of intraarticular PRF in a group of 57 consecutive patients with chronic joint pain. Patients with intractable joint pain for more than 6 months were treated with IA PRF 40-45V for 10-15 min in small joints and 60V for 15 min in large joints using fluoroscopic confirmation of correct needle position. A total of 28 shoulders, 40 knees, 10 trapezio-metacarpal, and 11 first metatarso-phalangeal joints were treated. Results were evaluated at 1, 2, and 5 months. The procedure was repeated after 1 month in 10 patients with initial suboptimal results. Success was defined as a reduction of pain score by at least 50%. All groups showed significant reductions in pain scores at all three follow-up visits. Success rates were higher in small joints (90% and 82%, respectively) than large ones (64% and 60%, respectively). Interestingly, IA PRF was successful in 6 out of 10 patients who had undergone previous surgery, including 3 with prosthetic joint replacement and in 6 of the 10 repeated procedures. There were no significant adverse effects or complications. IA PRF induced significant pain relief of long duration in a majority of our patients with joint pain. The exact mechanism is unclear, but may be related to the exposure of immune cells to low-strength RF fields, inducing an anti-inflammatory effect. The success rate appears to be highest in small joints. We recommend additional research including control groups to further investigate and clarify this method; our data suggest that it may represent a useful modality in the treatment of arthrogenic pain.

  10. A clamping force measurement system for monitoring the condition of bolted joints on railway track joints and points

    NASA Astrophysics Data System (ADS)

    Tesfa, B.; Horler, G.; Thobiani, F. Al; Gu, F.; Ball, A. D.

    2012-05-01

    Many industrial structures associated with railway infrastructures rely on a large number of bolted joint connections to ensure safe and reliable operation of the track and trackside furniture. Significant sums of money are spent annually to repair the damage caused by bolt failures and to maintain the integrity of bolted structures. In the UK, Network Rail (the organization responsible for rail network maintenance and safety) conducts corrective and preventive maintenance manually on 26,000 sets of points (each having approximately 30 bolted joints per set), in order to ensure operational success and safety for the travelling public. Such manual maintenance is costly, disruptive, unreliable and prone to human error. The aim of this work is to provide a means of automatically measuring the clamping force of each individual bolted joint, by means of an instrumented washer. This paper describes the development of a sensor means to be used in the washer, which satisfies the following criteria. Sense changes in the clamping force of the joint and report this fact. Provide compatibility with the large dynamic range of clamping force. Satisfy the limitations in terms of physical size. Provide the means to electronically interface with the washer. Provide a means of powering the washer in situ. Provide a solution at an acceptable cost. Specifically the paper focuses on requirements 1, 2 and 3 and presents the results that support further development of the proposed design and the realization of a pre-prototype system. In the paper, various options for the force sensing element (strain gage, capacitor, piezo-resistive) have been compared, using design optimization techniques. As a result of the evaluation, piezo-resistive sensors in concert with a proprietary force attenuation method, have been found to offer the best performance and cost trade-off The performance of the novel clamping force sensor has been evaluated experimentally and the results show that a smart washer

  11. Restoration of horizontal stability in complete acromioclavicular joint separations: surgical technique and preliminary results.

    PubMed

    Li, Haoqing; Wang, Chuanshun; Wang, Jiandong; Wu, Kai; Hang, Donghua

    2013-11-13

    Our purpose was to investigate the clinical efficacy of arthroscope-assisted acromioclavicular ligament reconstruction in combination with double endobutton coracoclavicular ligament reconstruction for the treatment of complete acromioclavicular joint dislocation. During the period from February 2010 to October 2012, ten patients with Rockwood types IV and V acromioclavicular joint dislocation were hospitalized and nine were treated with acromioclavicular ligament reconstruction combined with double endobutton of coracoclavicular ligament reconstruction. The improvement in shoulder functions was assessed using a Constant score and visual analog scale (VAS) system. The mean follow-up period was 33.6 ± 5.4 months. The mean Constant scores improved from 25.2 ± 6.6 preoperatively to 92.4 ± 6.5 postoperatively, while the mean VAS score decreased from 5.9 ± 1.4 to 1.2 ± 0.9; significant differences were observed. The final follow-up revealed that excellent outcomes were achieved in eight patients and good outcome in two patients. Arthroscope-assisted acromioclavicular ligament reconstruction in combination with double endobutton of coracoclavicular ligament reconstruction is an effective approach for treatment of acute complete acromioclavicular joint dislocation.

  12. Posterior subtalar joint synoviography and corticosteroid injection in rheumatoid arthritis.

    PubMed Central

    Beaudet, F; Dixon, A S

    1981-01-01

    Ten posterior subtalar joints of 8 patients with rheumatoid arthritis and 12 posterior subtalar joints of 6 cadavers were studied by contrast synoviography. In the rheumatoid group the abnormalities included posterior capsule distension, filling defects caused by hypertrophic synovitis, limited or irregular filling of the anterior recess of the joint in 5 out of 10, and communication with the ankle joint in 3 out of 10. None of the cadaveric joints showed posterior capsule distension or limited or irregular filling of the anterior recess of the joint, but communication with the ankle was present in 2 joints. The joints of the patients were injected with a 1:1 mixture of sodium iothalamate 70% (Conray 420) and triamcinolone hexacetonide (Lederspan) 20 mg/ml. All patients noticed a decrease in and an improvement in walking beginning 24-48 hours after the examination. Quantitative thermography was done immediately before and 1 after injection in 2 patients who showed an improvement in thermographic index. We conclude that hindfoot inflammatory pain arising from the posterior subtalar joint is caused by distension with hypertrophic synovitis which can be difficult to detect clinically. Images PMID:7224686

  13. Degenerative joint disease: multiple joint involvement in young and mature dogs.

    PubMed

    Olsewski, J M; Lust, G; Rendano, V T; Summers, B A

    1983-07-01

    Radiologic, pathologic, and ancillary methods were used to determine the occurrence of degenerative joint disease involving multiple joints of immature and adult dogs. Animals were selected for the development of hip joint dysplasia and chronic degenerative joint disease. Of disease-prone dogs, 82% (45 of 55 dogs) had radiologic changes, indicative of hip dysplasia, by 1 year of age. At necropsy, more abnormal joints were identified than by radiographic examination. Among 92 dogs between 3 to 11 months of age that had joint abnormalities, 71% had hip joint involvement; 38%, shoulder joint involvement; 22%, stifle joint involvement; and 40% had multiple joint involvement. Polyarthritis was asymptomatic and unexpected. Radiographic examination of older dogs also revealed evidence of degenerative joint disease in many joints. Multiple joint involvement was substantiated at necropsy of young and mature dogs. A similar pattern of polyarticular osteoarthritis was revealed in a survey (computer search) of necropsy reports from medical case records of 100 adult and elderly dogs. Usually, the joint disease was an incidental observation, unrelated to the clinical disease or to the cause of death. The frequent occurrence of degenerative changes in several joints of dogs aged 6 months to 17 years indicated that osteoarthritis may be progressive in these joints and raises the possibility that systemic factors are involved in the disease process.

  14. Symptomatic lumbar facet joint cysts treated by CT-guided intracystic and intra-articular steroid injections.

    PubMed

    Amoretti, Nicolas; Huwart, Laurent; Foti, Pauline; Boileau, Pascal; Amoretti, Marie-Eve; Pellegrin, Amelie; Marcy, Pierre-Yves; Hauger, Olivier

    2012-12-01

    To evaluate percutaneous computed tomography (CT)-guided intracystic and intra-articular steroid injections for the treatment of lumbar facet joint cyst causing radicular pain. A single-centre prospective study involving 120 consecutive patients with symptomatic lumbar facet joint cyst-induced radicular pain was done (72 women, 48 men). The average age was 68.2 years (52-84). Patients were treated by percutaneous CT-guided intracystic and intra-articular steroid injections. The clinical course of nerve root pain was evaluated after 1 day, and 1, 3 and 6 months, with long-term follow-up after 12 months. Patient follow-ups in our series show supportive results: within 120 patients, 54% of patients were satisfied with a long-lasting result from the first intra-cystic and intra-articular steroid injections (n = 65), while 20.8% were satisfied with a long-lasting result from a second intervention. Combining these two results shows that 75% of patients were satisfied with a long-lasting result. Our results showed that percutaneous treatment of vertebral lumbar facet joint cysts by double injections is an effective and economic therapeutic technical management among 75% of our patients. Thus we recommend that it should be considered as a first choice of treatment. Lumbar facet joint cysts are a common feature of back and radicular pain. They may be treated effectively by interventional radiologists using CT guidance. Percutaneous treatment using double injections can save surgery in 75% of patients.

  15. [Clinical Trial to Test the iFuse Implant System® in Patients with Sacroiliac Joint Syndrome: One Year Results].

    PubMed

    Bornemann, R; Pflugmacher, R; Webler, M; Koch, E M W; Dengler, J; Wirtz, D C; Frey, S P

    2016-12-01

    Background: This study reports one year post-operative monitoring of the efficacy and safety of iFuse Implant System® in patients with sacroiliac joint syndrome. Material and Methods: After 6 months of inadequate conservative treatment, patients with properly proven ISG syndrome were selected for surgery. The iFuse implants had a triangular profile and coating of porous titanium plasma spray and were used in the minimally invasive procedures. The procedure was performed under general anaesthesia and fluoroscopic control. In each case, three implants were placed. Results: 24 patients (22 f; 92 %; 54.9 ± 14 years) participated in the study. The operations were performed in 11 patients (46 %) on the left and in 13 patients (54 %) on the right. The mean operative time was 42.4 minutes (95 % CI: 35.6-49.3). The reduction in pain intensity on the VAS scale was 58 ± 11 mm (68 ± 7 %). The Oswestry score showed a median decrease of 44 percentage points (57 %). After 12 months, 15 patients (63 %) reported that they were taking no more painkillers. Conclusion: The minimally invasive treatment of patients with sacroiliac joint syndrome using the iFuse Implant System leads to significant analgesic effects over the period of one year; it also contributes significantly to improving the functioning of the patient. Georg Thieme Verlag KG Stuttgart · New York.

  16. Biomechanical evaluation of native acromioclavicular joint ligaments and two reconstruction techniques in the presence of the sternoclavicular joint: A cadaver study.

    PubMed

    Masionis, Povilas; Šatkauskas, Igoris; Mikelevičius, Vytautas; Ryliškis, Sigitas; Bučinskas, Vytautas; Griškevičius, Julius; Martin Oliva, Xavier; Monzó Planella, Mariano; Porvaneckas, Narūnas; Uvarovas, Valentinas

    2017-01-01

    Where is over 100 reconstruction techniques described for acromioclavicular (AC) joint reconstruction. Although, it is not clear whether the presence of the sternoclavicular (SC) joint influences the biomechanical properties of native AC ligaments and reconstruction techniques. The purpose of the present study was to investigate the biomechanical properties of native AC joint ligaments and two reconstruction techniques in cadavers with the SC joint still present. We tested eight fresh-frozen cadaver hemithoraces for superior translation (70 N load) and translation increment after 1000 cycles (loading from 20 to 70 N) in a controlled laboratory study. There were three testing groups created: native ligaments, the single coracoclavicular loop (SCL) technique, and the two coracoclavicular loops (TCL) technique. Superior translation was measured after static loading. Translation increment was calculated as the difference between superior translation after cyclic and static loading. Native AC ligaments showed significantly lower translation than the SCL ( p = 0.023) and TCL ( p = 0.046) groups. The SCL had a significantly lower translation increment than native AC ligaments ( p = 0.028). There was no significant difference between reconstruction techniques in terms of translation ( p = 0.865) and translation increment ( p = 0.113). Native AC joint ligaments had better static properties than both reconstruction techniques and worse dynamic biomechanical properties than the SCL technique. The SCL technique appeared to be more secure than the TCL technique. The presence of the SC joint did not have an observable influence on test results.

  17. Shear joint capability versus bolt clearance

    NASA Technical Reports Server (NTRS)

    Lee, H. M.

    1992-01-01

    The results of a conservative analysis approach into the determination of shear joint strength capability for typical space-flight hardware as a function of the bolt-hole clearance specified in the design are presented. These joints are comprised of high-strength steel fasteners and abutments constructed of aluminum alloys familiar to the aerospace industry. A general analytical expression was first arrived at which relates bolt-hole clearance to the bolt shear load required to place all joint fasteners into a shear transferring position. Extension of this work allowed the analytical development of joint load capability as a function of the number of fasteners, shear strength of the bolt, bolt-hole clearance, and the desired factor of safety. Analysis results clearly indicate that a typical space-flight hardware joint can withstand significant loading when less than ideal bolt hole clearances are used in the design.

  18. Thermal Fatigue Evaluation of Pb-Free Solder Joints: Results, Lessons Learned, and Future Trends

    NASA Astrophysics Data System (ADS)

    Coyle, Richard J.; Sweatman, Keith; Arfaei, Babak

    2015-09-01

    Thermal fatigue is a major source of failure of solder joints in surface mount electronic components and it is critically important in high reliability applications such as telecommunication, military, and aeronautics. The electronic packaging industry has seen an increase in the number of Pb-free solder alloy choices beyond the common near-eutectic Sn-Ag-Cu alloys first established as replacements for eutectic SnPb. This paper discusses the results from Pb-free solder joint reliability programs sponsored by two industry consortia. The characteristic life in accelerated thermal cycling is reported for 12 different Pb-free solder alloys and a SnPb control in 9 different accelerated thermal cycling test profiles in terms of the effects of component type, accelerated thermal cycling profile and dwell time. Microstructural analysis on assembled and failed samples was performed to investigate the effect of initial microstructure and its evolution during accelerated thermal cycling test. A significant finding from the study is that the beneficial effect of Ag on accelerated thermal cycling reliability (measured by characteristic lifetime) diminishes as the severity of the accelerated thermal cycling, defined by greater ΔT, higher peak temperature, and longer dwell time increases. The results also indicate that all the Pb-free solders are more reliable in accelerated thermal cycling than the SnPb alloy they have replaced. Suggestions are made for future work, particularly with respect to the continued evolution of alloy development for emerging application requirements and the value of using advanced analytical methods to provide a better understanding of the effect of microstructure and its evolution on accelerated thermal cycling performance.

  19. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  20. Experimental characterization of deployable trusses and joints

    NASA Technical Reports Server (NTRS)

    Ikegami, R.; Church, S. M.; Keinholz, D. A.; Fowler, B. L.

    1987-01-01

    The structural dynamic properties of trusses are strongly affected by the characteristics of joints connecting the individual beam elements. Joints are particularly significant in that they are often the source of nonlinearities and energy dissipation. While the joints themselves may be physically simple, direct measurement is often necessary to obtain a mathematical description suitable for inclusion in a system model. Force state mapping is a flexible, practical test method for obtaining such a description, particularly when significant nonlinear effects are present. It involves measurement of the relationship, nonlinear or linear, between force transmitted through a joint and the relative displacement and velocity across it. An apparatus and procedure for force state mapping are described. Results are presented from tests of joints used in a lightweight, composite, deployable truss built by the Boeing Aerospace Company. The results from the joint tests are used to develop a model of a full 4-bay truss segment. The truss segment was statically and dynamically tested. The results of the truss tests are presented and compared with the analytical predictions from the model.

  1. Excluding joint probabilities from quantum theory

    NASA Astrophysics Data System (ADS)

    Allahverdyan, Armen E.; Danageozian, Arshag

    2018-03-01

    Quantum theory does not provide a unique definition for the joint probability of two noncommuting observables, which is the next important question after the Born's probability for a single observable. Instead, various definitions were suggested, e.g., via quasiprobabilities or via hidden-variable theories. After reviewing open issues of the joint probability, we relate it to quantum imprecise probabilities, which are noncontextual and are consistent with all constraints expected from a quantum probability. We study two noncommuting observables in a two-dimensional Hilbert space and show that there is no precise joint probability that applies for any quantum state and is consistent with imprecise probabilities. This contrasts with theorems by Bell and Kochen-Specker that exclude joint probabilities for more than two noncommuting observables, in Hilbert space with dimension larger than two. If measurement contexts are included into the definition, joint probabilities are not excluded anymore, but they are still constrained by imprecise probabilities.

  2. Spacesuit mobility joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1978-01-01

    Joints for use in interconnecting adjacent segments of an hermetically sealed spacesuit which have low torques, low leakage and a high degree of reliability are described. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics. Linkages which restrain the joint from longitudinal distension and a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli are featured. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  3. [An attempt to use ultrasonic technique for confirming the diagnosis, planning and observation of long-term treatment results of painful temporo-mandibular joint dysfunction].

    PubMed

    Ey-Chmielewska, H

    1998-01-01

    The author presents an attempt of using ultrasonographic technique in diagnosis, planning and observation of treatment results of temporo-mandibular joint pain dysfunctions. Temporo-mandibular joint pain dysfunctions are interchangeably also called temporo-mandibular joint functional disorders. The assessment of pain symptoms in temporo-mandibular joint dysfunctions pain symptoms is principally based on a subjective estimation by the examining practitioner. There is no univocal definition of the disease or a simple index evidencing important symptoms in decision making. Additionally X-ray technique examinations, being hitherto used, in early stages of the disorder do not allow to diagnose it, and are also burdensome to a patient. The aim of this study was to confirm visibility of anatomical elements of the temporo-mandibular joint in an ultrasound examination, assess the mobility of the articular disc before, during and after prosthetic treatment with and without the use of ultrasound technique, and to determine the period of time necessary to obtain a therapeutic effect. The study material consisted of 180 patients, 128 women and 52 men, aged 20 to 60 years, treated by applying prostheses because of temporo-mandibular joint pain dysfunction, in the Department of Prosthetic Dentistry of the Pomeranian Medical Academy. The patients were divided into 2 groups, control and study group. The control group consisted of 90 patients, 63 women and 27 men. In this group prosthetic treatment planning and observation of results was based on a subjective estimation of the practitioner. The study group here comprised 90 patients, 65 women and 25 men, aged 26 to 60 years. In this group prosthetic treatment planning and observation of treatment results were carried on with the use of ultrasound technique. Data from both groups concerning history, results of examinations carried out by ultrasound technique, and the assessment of ultrasound examination were noted on standard

  4. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system.

    PubMed

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry(®) SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed.

  5. Airborne laser topographic mapping results from initial joint NASA/US Army Corps of Engineers experiment

    NASA Technical Reports Server (NTRS)

    Krabill, W. B.; Collins, J. G.; Swift, R. N.; Butler, M. L.

    1980-01-01

    Initial results from a series of joint NASA/US Army Corps of Engineers experiments are presented. The NASA Airborne Oceanographic Lidar (AOL) was exercised over various terrain conditions, collecting both profile and scan data from which river basin cross sections are extracted. Comparisons of the laser data with both photogrammetry and ground surveys are made, with 12 to 27 cm agreement observed over open ground. Foliage penetration tests, utilizing the unique time-waveform sampling capability of the AOL, indicate 50 cm agreement with photogrammetry (known to have difficulty in foliage covered terrain).

  6. Analysis of polyethylene terephthalate PET plastic bottle jointing system using finite element method (FEM)

    NASA Astrophysics Data System (ADS)

    Zaidi, N. A.; Rosli, Muhamad Farizuan; Effendi, M. S. M.; Abdullah, Mohamad Hariri

    2017-09-01

    For almost all injection molding applications of Polyethylene Terephthalate (PET) plastic was analyzed the strength, durability and stiffness of properties by using Finite Element Method (FEM) for jointing system of wood furniture. The FEM was utilized for analyzing the PET jointing system for Oak and Pine as wood based material of furniture. The difference pattern design of PET as wood jointing furniture gives the difference value of strength furniture itself. The results show the wood specimen with grooves and eclipse pattern design PET jointing give lower global estimated error is 28.90%, compare to the rectangular and non-grooves wood specimen of global estimated error is 63.21%.

  7. A model to explain joint patterns found in ignimbrite deposits

    NASA Astrophysics Data System (ADS)

    Tibaldi, A.; Bonali, F. L.

    2018-03-01

    The study of fracture systems is of paramount importance for economic applications, such as CO2 storage in rock successions, geothermal and hydrocarbon exploration and exploitation, and also for a better knowledge of seismogenic fault formation. Understanding the origin of joints can be useful for tectonic studies and for a geotechnical characterisation of rock masses. Here, we illustrate a joint pattern discovered in ignimbrite deposits of South America, which can be confused with conjugate tectonic joint sets but which have another origin. The pattern is probably common, but recognisable only in plan view and before tectonic deformation obscures and overprints it. Key sites have been mostly studied by field surveys in Bolivia and Chile. The pattern is represented by hundreds-of-meters up to kilometre-long swarms of master joints, which show circular to semi-circular geometries and intersections that have "X" and "Y" patterns. Inside each swarm, joints are systematic, rectilinear or curvilinear in plan view, and as much as 900 m long. In section view, they are from sub-vertical to vertical and do not affect the underlying deposits. Joints with different orientation mostly interrupt each other, suggesting they have the same age. This joint architecture is here interpreted as resulting from differential contraction after emplacement of the ignimbrite deposit above a complex topography. The set of the joint pattern that has suitable orientation with respect to tectonic stresses may act to nucleate faults.

  8. Real-Time Visualization of Joint Cavitation

    PubMed Central

    Rowe, Lindsay

    2015-01-01

    Cracking sounds emitted from human synovial joints have been attributed historically to the sudden collapse of a cavitation bubble formed as articular surfaces are separated. Unfortunately, bubble collapse as the source of joint cracking is inconsistent with many physical phenomena that define the joint cracking phenomenon. Here we present direct evidence from real-time magnetic resonance imaging that the mechanism of joint cracking is related to cavity formation rather than bubble collapse. In this study, ten metacarpophalangeal joints were studied by inserting the finger of interest into a flexible tube tightened around a length of cable used to provide long-axis traction. Before and after traction, static 3D T1-weighted magnetic resonance images were acquired. During traction, rapid cine magnetic resonance images were obtained from the joint midline at a rate of 3.2 frames per second until the cracking event occurred. As traction forces increased, real-time cine magnetic resonance imaging demonstrated rapid cavity inception at the time of joint separation and sound production after which the resulting cavity remained visible. Our results offer direct experimental evidence that joint cracking is associated with cavity inception rather than collapse of a pre-existing bubble. These observations are consistent with tribonucleation, a known process where opposing surfaces resist separation until a critical point where they then separate rapidly creating sustained gas cavities. Observed previously in vitro, this is the first in-vivo macroscopic demonstration of tribonucleation and as such, provides a new theoretical framework to investigate health outcomes associated with joint cracking. PMID:25875374

  9. Effect of Nd:YAG laser beam welding on weld morphology and mechanical properties of Ti-6Al-4V butt joints and T-joints

    NASA Astrophysics Data System (ADS)

    Kashaev, Nikolai; Ventzke, Volker; Fomichev, Vadim; Fomin, Fedor; Riekehr, Stefan

    2016-11-01

    A Nd:YAG single-sided laser beam welding process study for Ti-6Al-4V butt joints and T-joints was performed to investigate joining techniques with regard to the process-weld morphology relationship. An alloy compatible filler wire was used to avoid underfills and undercuts. The quality of the butt joints and T-joints was characterized in terms of weld morphology, microstructure and mechanical properties. Joints with regular shapes, without visible cracks, pores, and geometrical defects were achieved. Tensile tests revealed high joint integrity in terms of strength and ductility for both the butt joint and T-joint geometries. Both the butt joints and T-joints showed base material levels of strength. The mechanical performance of T-joints was also investigated using pull-out tests. The performance of the T-joints in such tests was sensitive to the shape and morphology of the welds. Fracture always occurred in the weld without any plastic deformation in the base material outside the weld.

  10. [Meniscoids of the intervertebral joints].

    PubMed

    Kos, J; Hert, J; Sevcík, P

    2002-01-01

    developed meniscoids were fat pads, in the others, these were synovial meniscoids. Spines of younger individuals showed a predominance of synovial meniscoids with smooth surfaces that arched against the articular cavity. In spines of elderly individuals, meniscoids were rough, in some cases fibrous in structure, and had a lobulated or frayed edge. The shape, location of meniscoids and their presence in every joint indicate their definite role for the spine: they compensate the incongruence of articular surfaces, fill in empty spaces and facilitate spread of synovial fluid during translation movements. Variability in shape, size and location of meniscoids give support to the view that meniscoids developed secondarily in relation to the morphogenesis of articular surfaces and that they are fully adapted to the shape and function of the joint. Mobile meniscoids, particularly fibrous ones, can get wedged between articular surfaces due to a sudden, rush movement (entrapment theory) or can be caught between the edge of an articular surface and the articular capsule attachment (extrapment theory). This situation may result in either mechanical or functional blockade of the spine and a subsequent painful condition due to compression of nerves and reflex contraction of muscles. Direct evidence of such blockade and the validity of either hypothesis can today be provided by magnetic resonance imaging. All intervertebral joints, along the length of spine, possess capsule processes, i.e., meniscoids, which can be classified as synovial, fat and fibrous. Meniscoids are most developed in the lumbar and cervical spine. They serve to compensate for the incongruence of articular surfaces and to fill in empty spaces. Mobile, peduncular meniscoids can, at sudden or non-physiological movements, be caught between articular surfaces and cause spinal blockade and painful conditions. Manipulative treatment is, therefore, justified in indicated cases.

  11. Functionally Graded Adhesives for Composite Joints

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    Adhesives with functionally graded material properties are being considered for use in adhesively bonded joints to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. An enhanced joint finite element, which uses an analytical formulation to obtain exact shape functions, is used to model the joint. Furthermore, proof of concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint.

  12. [Trigeminal motor paralysis and dislocation of the temporo-mandibular joints].

    PubMed

    Ohkawa, S; Yoshida, T; Ohsumi, Y; Tabuchi, M

    1996-07-01

    A 64-year-old woman with diabetes mellitus was admitted to our hospital with left hemiparesis of sudden onset. A brain MRI demonstrated a cerebral infarction in the ventral part of the right lower pons. When left hemiparesis worsened, she had dislocation of the temporo-mandibular joints repeatedly. Then, her lower jaw deviated to the right when she opened her mouth. Also, there was decreased contraction of the right masseter when she clenched her teeth. These findings suggest that there was trigeminal motor paralysis on the right side resulting from involvement of the intrapontine trigeminal motor nerve. She has no history of dislocation of the temporo-mandibular joints. An X-ray film showed that the temporo-mandibular joints were intact. Thus, it is possible that deviation of the lower jaw was the cause of this dislocation. We suspect that dislocation of the temporo-mandibular joints may occur as a complication of unilateral trigeminal motor paralysis. This has not been reported to our knowledge.

  13. Dynamic Cytology and Transcriptional Regulation of Rice Lamina Joint Development.

    PubMed

    Zhou, Li-Juan; Xiao, Lang-Tao; Xue, Hong-Wei

    2017-07-01

    Rice ( Oryza sativa ) leaf angle is determined by lamina joint and is an important agricultural trait determining leaf erectness and, hence, the photosynthesis efficiency and grain yield. Genetic studies reveal a complex regulatory network of lamina joint development; however, the morphological changes, cytological transitions, and underlying transcriptional programming remain to be elucidated. A systemic morphological and cytological study reveals a dynamic developmental process and suggests a common but distinct regulation of the lamina joint. Successive and sequential cell division and expansion, cell wall thickening, and programmed cell death at the adaxial or abaxial sides form the cytological basis of the lamina joint, and the increased leaf angle results from the asymmetric cell proliferation and elongation. Analysis of the gene expression profiles at four distinct developmental stages ranging from initiation to senescence showed that genes related to cell division and growth, hormone synthesis and signaling, transcription (transcription factors), and protein phosphorylation (protein kinases) exhibit distinct spatiotemporal patterns during lamina joint development. Phytohormones play crucial roles by promoting cell differentiation and growth at early stages or regulating the maturation and senescence at later stages, which is consistent with the quantitative analysis of hormones at different stages. Further comparison with the gene expression profile of leaf inclination1 , a mutant with decreased auxin and increased leaf angle, indicates the coordinated effects of hormones in regulating lamina joint. These results reveal a dynamic cytology of rice lamina joint that is fine-regulated by multiple factors, providing informative clues for illustrating the regulatory mechanisms of leaf angle and plant architecture. © 2017 American Society of Plant Biologists. All Rights Reserved.

  14. Sea urchin puncture resulting in PIP joint synovial arthritis: case report and MRI study.

    PubMed

    Liram, N; Gomori, M; Perouansky, M

    2000-01-01

    Of the 600 species of sea urchins, approximately 80 may be venomous to humans. The long spined or black sea urchin, Diadema setosum may cause damage by the breaking off of its brittle spines after they penetrate the skin. Synovitis followed by arthritis may be an unusual but apparently not a rare sequel to such injury, when implantation occurs near a joint. In this case report, osseous changes were not seen by plain x-rays. Magnetic resonance imaging (MRI) was used to expose the more salient features of both soft tissue and bone changes of black sea urchin puncture injury 30 months after penetration. In all likelihood, this type of injury may be more common than the existing literature at present suggests. It is believed to be the first reported case in this part of the world as well as the first MRI study describing this type of joint pathology. Local and systemic reactions to puncture injuries from sea urchin spines have been described previously. These may range from mild, local irritation lasting a few days to granuloma formation, infection and on occasions systemic illness. The sea urchin spines are composed of calcium carbonate with proteinaceous covering. The covering tends to cause immune reactions of variable presentation. There are only a handful of reported cases with sea urchin stings on record, none of them from the Red Sea. However, this condition is probably more common than is thought and can present difficulty in diagnosis. In this case report, the inflammation responded well to heat treatment, mobilization and manipulation of the joint in its post acute and chronic stages. As some subtle changes in soft tissues and the changes in bone were not seen either on plain x-rays or ultrasound scan, gadolinium-enhanced MRI was used to unveil the marked changes in the joint.

  15. [Arthrodesis of the infected ankle joint: results with the Ilizarov external fixator].

    PubMed

    Gessmann, J; Ozokyay, L; Fehmer, T; Muhr, G; Seybold, D

    2011-04-01

    The treatment of severe bacterial infections of the ankle joint is difficult and complex. In the case of a chronic infection with destruction of the ankle joint, a tibiotalar arthrodesis with external fixation is the treatment of choice. In this study the results of ankle arthrodesis due to bacterial infection using the Ilizarov external fixator are presented. Between 2001 and 2004 37 patients (10 female, 27 male, mean age 58 years) were treated with a tibiotalar arthrodesis using the Ilizarov fixator. All patients had a confirmed infection in the course of their disease. Active infection was present in 20 patients at the time of the operation. Most secondary ankle arthritides (81 %) were caused post-traumatically after various internal fixation procedures. Previous ankle arthrodeses were tried in 14 cases (12 cases with internal fixation, two cases with external monolateral fixation). Patients were treated with a four-ring Ilizarov frame (in two cases with a five-ring frame) and stainless steel wires. All patients could be included at a mean follow-up of 46 (12-49) months. A modified AOFAS score was used for the functional outcome. The operation took 141 minutes at an average ranging from 90 to 252 minutes. The inpatient treatment lasted between 10 and 63 days (mean 26 days). The time spent in the fixator was 116.7 (69-245) days. All patients were mobilised under full weight bearing with the external fixator. Surgical revision was necessary in 13 patients: four patients needed wound revisions due to ongoing infection, six patients needed wire exchange due to deep infection in three cases and wire breakage in three cases, one patient needed additional wires because of an initially instable frame configuration and two patients needed secondary skin grafting. Bony consolidation was achieved in 32 patients (86.5 %). With a re-arthrodesis performed in four patients using the Ilizarov fixator, the overall fusion rate was 94.6 %. Infection was persistent in two cases

  16. Reusable Solid Rocket Motor Nozzle Joint 5 Redesign

    NASA Technical Reports Server (NTRS)

    Lui, R. C.; Stratton, T. C.; LaMont, D. T.

    2003-01-01

    Torque tension testing of a newly designed Reusable Solid Rocket Motor nozzle bolted assembly was successfully completed. Test results showed that the 3-sigma preload variation was as expected at the required input torque level and the preload relaxation were within the engineering limits. A shim installation technique was demonstrated as a simple process to fill a shear lip gap between nozzle housings in the joint region. A new automated torque system was successfully demonstrated in this test. This torque control tool was found to be very precise and accurate. The bolted assembly performance was further evaluated using the Nozzle Structural Test Bed. Both current socket head cap screw and proposed multiphase alloy bolt configurations were tested. Results indicated that joint skip and bolt bending were significantly reduced with the new multiphase alloy bolt design. This paper summarizes all the test results completed to date.

  17. Arthroscopic sternoclavicular joint resection arthroplasty: a technical note and illustrated case report.

    PubMed

    Warth, Ryan J; Lee, Jared T; Campbell, Kevin J; Millett, Peter J

    2014-02-01

    Open resection arthroplasty of the sternoclavicular (SC) joint has historically provided good long-term results in patients with symptomatic osteoarthritis of the SC joint. However, the procedure is rarely performed because of the risk of injury to vital mediastinal structures and concern regarding postoperative joint instability. Arthroscopic decompression of the SC joint has therefore emerged as a potential treatment option because of many recognized advantages including minimal tissue dissection, maintenance of joint stability, avoidance of posterior SC joint dissection, expeditious recovery, and improved cosmesis. There are, however, safety concerns given the proximity of neurovascular structures. In this article we demonstrate a technique for arthroscopic SC joint resection arthroplasty in a 26-year-old active man with bilateral, painful, idiopathic degenerative SC joint osteoarthritis. This case also highlights the pearls and pitfalls of arthroscopic resection arthroplasty for the SC joint. There were no perioperative complications. Four months postoperatively, the patient had returned to full activities, including weightlifting, without pain or evidence of SC joint instability. One year postoperatively, the patient showed substantial improvements in the American Shoulder and Elbow Surgeons score; Single Assessment Numeric Evaluation score; Quick Disabilities of the Arm, Shoulder and Hand score; and Short Form 12 Physical Component Summary score over preoperative baseline values.

  18. Functional disorders of the temporomandibular joints: Internal derangement of the temporomandibular joint.

    PubMed

    Chang, Chih-Ling; Wang, Ding-Han; Yang, Mu-Chen; Hsu, Wun-Eng; Hsu, Ming-Lun

    2018-04-01

    Temporomandibular joint (TMJ) is one of the most complex joints of the human body. Due to its unique movement, in terms of combination of rotation and translator movement, disc of the joint plays an important role to maintain its normal function. In order to sustain the normal function of the TMJ, disc must be kept in proper position as well as maintain normal shape in all circumstances. Once the disc is not any more in its normal position during function of the joint, disturbance of the joint can be occurred which will lead to subsequent distortion of the disc. Shape of the disc can be influenced by many factors i.e.: abnormal function or composition of the disc itself. Etiology of the internal derangement of the disc remains controversial. Multifactorial theory has been postulated in most of previous manuscripts. Disc is composed of mainly extracellular matrix. Abnormal proportion of collagen type I & III may also leads to joint hypermobility which may be also a predisposing factor of this disorder. Thus it can be recognized as local manifestation of a systemic disorder. Different treatment modalities with from conservative treatment to surgical intervention distinct success rate have been reported. Recently treatment with extracellular matrix injection becomes more and more popular to strengthen the joint itself. Since multifactorial in character, the best solution of the treatment modalities should be aimed to resolve possible etiology from different aspects. Team work may be indication to reach satisfied results. Copyright © 2018. Published by Elsevier Taiwan.

  19. Microstructure and mechanical properties of China low activation martensitic steel joint by TIG multi-pass welding with a new filler wire

    NASA Astrophysics Data System (ADS)

    Huang, Bo; Zhang, Junyu; Wu, Qingsheng

    2017-07-01

    Tungsten Inner Gas (TIG) welding is employed for joining of China low activation martensitic (CLAM) steel. A new filler wire was proposed, and the investigation on welding with various heat input and welding passes were conducted to lower the tendency towards the residual of δ ferrite in the joint. With the optimized welding parameters, a butt joint by multi-pass welding with the new filler wire was prepared to investigate the microstructure and mechanical properties. The microstructure of the joint was observed by optical microscope (OM) and scanning electron microscope (SEM). The hardness, Charpy impact and tensile tests of the joint were implemented at room temperature (25 °C). The results revealed that almost full martensite free from ferrite in the joints were obtained by multipass welding with the heat input of 2.26 kJ/mm. A certain degree of softening occurred at the heat affected zone of the joint according to the results of tensile and hardness tests. The as welded joints showed brittle fracture in the impact tests. However, the joints showed toughness fracture after tempering and relatively better comprehensive performance were achieved when the joints were tempered at 740 °C for 2 h.

  20. Poly(ethylene glycol)/chitosan/sodium glycerophosphate gel replaced the joint capsule with slow-release lubricant after joint surgery.

    PubMed

    Lu, Hailin; Ren, Shanshan; Li, Xing; Guo, Junde; Dong, Guangneng; Li, Jianhui; Gao, Li

    2018-08-01

    Body fluid is normally the only lubricant after joint replacement surgery, but wear problems have occurred because body fluid has poor lubrication ability. However, traditional lubricant would be diluted by body fluids and then absorbed by the human body. Therefore, an injectable gel with the ability to slow-release lubricant was designed to replace the joint capsule. The proposed gel, poly(ethylene glycol)/chitosan/sodium glycerophosphate (PEG/CS/GP) composite gel was then tested. The tribology results showed that the PEG/CS/GP gel had excellent slow-release properties, especially under pressure, and the PEG played an important role in improving the gel's rheological and mechanical properties. Moreover, this study revealed that the release solution had a good lubrication effect because the PEG and GP could crosslink via the hydrogen bond effect.

  1. Facet joint laser radiation: tissue effects of a new clinical laser application

    NASA Astrophysics Data System (ADS)

    Werkmann, Klaus; Thal, Dietmar R.

    1996-01-01

    Chronic unilateral and bilateral back pain with pseudoradicular symptoms, is a common clinical syndrome, which in many cases can be related to the facet joint syndrome. The pain is caused by mechanical affection of synovial and capsular nerve terminals. Therefore, current therapeutical attempts including physical therapy, intra-articular injection of local anesthetics and steroids and thermocoagulation of the facet joint with a thermocoagulator, are performed. We confirmed laser coagulation of the facet joint. Porcine cadaveric spines were treated immediately after death by intra-articular facet joint laser radiation. With the pulsed Nd:YAG laser (1064 nm) altogether 600 J were applied in three different places 4 mm apart at the top of the facet joint. The results showed that facet joint laser radiation leads to a small (about 1 - 2 mm diameter) lesion restricted to the facet joint cavity and its synovia. Histologically, we found a central carbonization zone and necrosis, including almost the whole cartilage and approximately 0.2 mm of the adjacent bone. These changes are similar to Nd:Yag-laser applications in other skeletal regions. It is suggested that these changes may lead to facet joint denervation by coagulation of the synovial nerve terminals. Cicatration of the laser lesion might cause ankylosis of this joint. In sum, facet joint laser radiation could be an alternative therapeutical tool for lower back pain of the facet joint syndrome type. Therefore, future clinical application of this technique seems to be very promising.

  2. Changes in ankle joint motion after Supramalleolar osteotomy: a cadaveric model.

    PubMed

    Kim, Hak Jun; Yeo, Eui Dong; Rhyu, Im Joo; Lee, Soon-Hyuck; Lee, Yeon Soo; Lee, Young Koo

    2017-09-09

    Malalignment of the ankle joint has been found after trauma, by neurological disorders, genetic predisposition and other unidentified factors, and results in asymmetrical joint loading. For a medial open wedge supramalleolar osteotomy(SMO), there are some debates as to whether concurrent fibular osteotomy should be performed. We assessed the changes in motion of ankle joint and plantar pressure after supramalleolar osteotomy without fibular osteotomy. Ten lower leg specimens below the knee were prepared from fresh-frozen human cadavers. They were harvested from five males (10 ankles)whose average age was 70 years. We assessed the motion of ankle joint as well as plantar pressure for SS(supra-syndesmotic) SMO and IS(intra-syndesmotic) SMO. After the osteotomy, each specimen was subjected to axial compression from 20 N preload to 350 N representing half-body weight. For the measurement of the motion of ankle joint, the changes in gap and point, angles in ankle joint were measured. The plantar pressure were also recorded using TekScan sensors. The changes in the various gap, point, and angles movements on SS-SMO and IS-SMO showed no statistically significant differences between the two groups. Regarding the shift of plantar center of force (COF) were noted in the anterolateral direction, but not statistically significant. SS-SMO and IS-SMO with intact fibula showed similar biomechanical effect on the ankle joint. We propose that IS-SMO should be considered carefully for the treatment of osteoarthrosis when fibular osteotomy is not performed because lateral cortex fracture was less likely using the intrasyndesmosis plane because of soft tissue support.

  3. Comparative Study of ENIG and ENEPIG as Surface Finishes for a Sn-Ag-Cu Solder Joint

    NASA Astrophysics Data System (ADS)

    Yoon, Jeong-Won; Noh, Bo-In; Jung, Seung-Boo

    2011-09-01

    Interfacial reactions and joint reliability of Sn-3.0Ag-0.5Cu solder with two different surface finishes, electroless nickel-immersion gold (ENIG) and electroless nickel-electroless palladium-immersion gold (ENEPIG), were evaluated during a reflow process. We first compared the interfacial reactions of the two solder joints and also successfully revealed a connection between the interfacial reaction behavior and mechanical reliability. The Sn-Ag-Cu/ENIG joint exhibited a higher intermetallic compound (IMC) growth rate and a higher consumption rate of the Ni(P) layer than the Sn-Ag-Cu/ENEPIG joint. The presence of the Pd layer in the ENEPIG suppressed the growth of the interfacial IMC layer and the consumption of the Ni(P) layer, resulting in the superior interfacial stability of the solder joint. The shear test results show that the ENIG joint fractured along the interface, exhibiting indications of brittle failure possibly due to the brittle IMC layer. In contrast, the failure of the ENEPIG joint only went through the bulk solder, supporting the idea that the interface is mechanically reliable. The results from this study confirm that the Sn-Ag-Cu/ENEPIG solder joint is mechanically robust and, thus, the combination is a viable option for a Pb-free package system.

  4. Mechanical Behavior of Dowel-Type Joints Made of Wood Scrimber Composite

    PubMed Central

    He, Minjuan; Tao, Duo; Li, Zheng; Li, Maolin

    2016-01-01

    As a renewable building material with low embodied energy characteristics, wood has gained more and more attention in the green and sustainable building industry. In terms of material resource and physical properties, scrimber composite not only makes full use of fast-growing wood species, but also has better mechanical performance and less inherent variability than natural wood material. In this study, the mechanical behavior of bolted beam-to-column joints built with a kind of scrimber composite was investigated both experimentally and numerically. Two groups of specimens were tested under monotonic and low frequency cyclic loading protocols. The experimental results showed that the bolted joints built with scrimber composite performed well in initial stiffness, ductility, and energy dissipation. A three-dimensional (3D) non-linear finite element model (FEM) for the bolted beam-to-column joints was then developed and validated by experimental results. The validated model was further used to investigate the failure mechanism of the bolted joints through stress analysis. This study can contribute to the application of the proposed scrimber composite in structural engineering, and the developed FEM can serve as a useful tool to evaluate the mechanical behavior of such bolted beam-to-column joints with different configurations in future research. PMID:28773703

  5. Mechanical Behavior of Dowel-Type Joints Made of Wood Scrimber Composite.

    PubMed

    He, Minjuan; Tao, Duo; Li, Zheng; Li, Maolin

    2016-07-15

    As a renewable building material with low embodied energy characteristics, wood has gained more and more attention in the green and sustainable building industry. In terms of material resource and physical properties, scrimber composite not only makes full use of fast-growing wood species, but also has better mechanical performance and less inherent variability than natural wood material. In this study, the mechanical behavior of bolted beam-to-column joints built with a kind of scrimber composite was investigated both experimentally and numerically. Two groups of specimens were tested under monotonic and low frequency cyclic loading protocols. The experimental results showed that the bolted joints built with scrimber composite performed well in initial stiffness, ductility, and energy dissipation. A three-dimensional (3D) non-linear finite element model (FEM) for the bolted beam-to-column joints was then developed and validated by experimental results. The validated model was further used to investigate the failure mechanism of the bolted joints through stress analysis. This study can contribute to the application of the proposed scrimber composite in structural engineering, and the developed FEM can serve as a useful tool to evaluate the mechanical behavior of such bolted beam-to-column joints with different configurations in future research.

  6. Parameter identification and optimization of slide guide joint of CNC machine tools

    NASA Astrophysics Data System (ADS)

    Zhou, S.; Sun, B. B.

    2017-11-01

    The joint surface has an important influence on the performance of CNC machine tools. In order to identify the dynamic parameters of slide guide joint, the parametric finite element model of the joint is established and optimum design method is used based on the finite element simulation and modal test. Then the mode that has the most influence on the dynamics of slip joint is found through harmonic response analysis. Take the frequency of this mode as objective, the sensitivity analysis of the stiffness of each joint surface is carried out using Latin Hypercube Sampling and Monte Carlo Simulation. The result shows that the vertical stiffness of slip joint surface constituted by the bed and the slide plate has the most obvious influence on the structure. Therefore, this stiffness is taken as the optimization variable and the optimal value is obtained through studying the relationship between structural dynamic performance and stiffness. Take the stiffness values before and after optimization into the FEM of machine tool, and it is found that the dynamic performance of the machine tool is improved.

  7. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system

    PubMed Central

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry® SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed. PMID:24851059

  8. Joint source based analysis of multiple brain structures in studying major depressive disorder

    NASA Astrophysics Data System (ADS)

    Ramezani, Mahdi; Rasoulian, Abtin; Hollenstein, Tom; Harkness, Kate; Johnsrude, Ingrid; Abolmaesumi, Purang

    2014-03-01

    We propose a joint Source-Based Analysis (jSBA) framework to identify brain structural variations in patients with Major Depressive Disorder (MDD). In this framework, features representing position, orientation and size (i.e. pose), shape, and local tissue composition are extracted. Subsequently, simultaneous analysis of these features within a joint analysis method is performed to generate the basis sources that show signi cant di erences between subjects with MDD and those in healthy control. Moreover, in a cross-validation leave- one-out experiment, we use a Fisher Linear Discriminant (FLD) classi er to identify individuals within the MDD group. Results show that we can classify the MDD subjects with an accuracy of 76% solely based on the information gathered from the joint analysis of pose, shape, and tissue composition in multiple brain structures.

  9. A microstructurally based model of solder joints under conditions of thermomechanical fatigue

    NASA Astrophysics Data System (ADS)

    Frear, D. R.; Burchett, S. N.; Rashid, M. M.

    The thermomechanical fatigue failure of solder joints is increasingly becoming an important reliability issue. We present two computational methodologies that have been developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions that are based on metallurgical tests as fundamental input for constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations from this model agree well with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. The single phase model is a computational technique that was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests and the results showed an adequate fit to experimental results. The single-phase model could be very useful for conditions where microstructural evolution is not a dominant factor in fatigue.

  10. [Arthroscopic therapy of ankle joint impingement syndrome after operation of ankle joint fracture dislocation].

    PubMed

    Feng, Zhibin; Mi, Kun; Wei, Renzhi; Liu, Wu; Wang, Bin

    2011-07-01

    To study the operative procedure and the effectiveness of arthroscopic therapy for ankle joint impingement syndrome after operation of ankle joint fracture dislocation. Between March 2008 and April 2010, 38 patients with ankle joint impingement syndrome after operation of ankle joint fracture dislocation were treated. Among them, there were 28 males and 10 females with an average age of 28 years (range, 18 to 42 years). The time from internal fixation to admission was 12-16 months (mean, 13.8 months). There were pressing pain in anterolateral and anterior ankle. The dorsal extension ranged from -20 to -5 degrees (mean, -10.6 degrees), and the palmar flexion was 30-40 degrees (mean, 35.5 degrees). The total score was 48.32 +/- 9.24 and the pain score was 7.26 +/- 1.22 before operation according to American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. The X-ray films showed osteophyte formation in anterior tibia and talus; MRI showed cartilage injury in 22 cases. Arthroscopic intervention included removing osteophytes, debriding fabric scars and synovial membrane tissues, and removing osteochondral fragments. Arthroscopic microfracture technique was used in 22 patients with cartilage injury. All incisions healed primarily. Thirty-eight cases were followed up 10-26 months (mean, 16 months). At last follow-up, 26 patients had normal range of motion (ROM); the dorsal extension was 15-25 degrees (mean, 19.6 degrees) and the palmar flexion was 35-45 degrees (mean, 40.7 degrees). Eight patients had mild limited ROM; the dorsal extension was 5-15 degrees (mean, 7.2 degrees) and the palmar flexion was 35-45 degrees (mean, 39.5 degrees). Four patients had mild limited ROM and pain in posterior portion of the ankle after a long walking (3-4 hours); the dorsal extension was 0-5 degrees (mean, 2.6 degrees) and the palmar flexion was 35-40 degrees (mean, 37.5 degrees). The total score was 89.45 +/- 9.55 and the pain score was 1.42 +/- 1.26 after

  11. Behavior of stress generated in semiconductor chips with high-temperature joints: Influence of mechanical properties of joint materials

    NASA Astrophysics Data System (ADS)

    Ito, H.; Kuwahara, M.; Ohta, R.; Usui, M.

    2018-04-01

    High-temperature joint materials are indispensable to realizing next-generation power modules with high-output performance. However, crack initiation resulting from stress concentration in semiconductor chips joined with high-temperature joint materials remains a critical problem in high-temperature operation. Therefore, clarifying the quantitative influence of joint materials on the stress generated in chips is essential. This study investigates the stress behavior of chips joined by Ni-Sn solid-liquid interdiffusion (SLID), which results in a high-temperature joint material likely to generate cracks after joining or when under thermal cycling. The results are compared with those fabricated using three types of solders, Pb-10%Sn, Sn-0.7%Cu, and Sn-10%Sb (mass %), which are conventional joint materials with different melting points and mechanical properties. Using Ni-Sn SLID results in the generation of high compressive stress (500 MPa) without stress relaxation after the joining process in contrast to the case of solders in which the compressive stresses are low (<300 MPa) and decrease to still lower levels (<250 MPa). In addition, no stress relaxation occurs during thermal cycling when using Ni-Sn SLID, whereas stress relaxation is clearly observed during heating to 200 °C using solders. Different stress behaviors between Ni-Sn SLID and other joint materials are illustrated by their mechanical strength and resistance against plastic and creep deformation. These results suggest that stress relaxation in a chip is key in suppressing crack initiation in highly reliable modules during high-temperature operation.

  12. Hállux Rígidus: prospective study of joint replacement with hemiarthroplasty

    PubMed Central

    dos Santos, Alexandre Leme Godoy; Duarte, Fernando Aires; Seito, Carlos Augusto Itiu; Ortiz, Rafael Trevisan; Sakaki, Marcos Hideyo; Fernandes, Túlio Diniz

    2013-01-01

    OBJECTIVE: To report the results of medium-term follow-up after deploying Arthrosurface-HemiCap(r) in patients with diagnosis of Hállux Rigidus (HR). METHOD: Eleven patients underwent partial Arthroplasty of the first metatarsal-phalangeal joint. Six women and five men with an average age 51.9 years (46 to 58 years) and average postoperative follow-up of 3.73 years (3-4 years); were classified through the Kravitz system and evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) scales for hállux, Visual Analogical Scale (VAS) - analog functional pain - and range of motion in the first metatarsal joint in preoperative, postoperative after six months and present post-operative. RESULTS: The results show significant improvement of the three analyzed parameters, both for overall analysis and for pre and post-operative comparisons individually. The comparative analysis of each variable in the six months and the current postoperative periods do not show statistically significant differences, indicating maintenance of parameters during this interval. CONCLUSION: hemiarthroplasty of first metatarsophalangeal joint is a reproducible and safe option for the surgical treatment of hállux rigidus II and III, with significant improvement of the evaluated parameters for the studied population. Level of Evidence IV, Case Series. PMID:24453646

  13. Joint NASA/EPA AVIRIS Analysis in the Chesapeake Bay Region: Plans and Initial Results

    NASA Technical Reports Server (NTRS)

    Johnson, Lee; Stokely, Peter; Lobitz, Brad; Shelton, Gary

    1998-01-01

    NASA's Ames Research Center is performing an AVIRIS demonstration project in conjunction with the U. S. Environmental Protection Agency (Region 3). NASA and EPA scientists have jointly defined a Study Area in eastern Virginia to include portions of the Chesapeake Bay, southern Delmarva Peninsula, and the mouths of the York and James Rivers. Several environmental issues have been identified for study. These include, by priority: 1) water constituent analysis in the Chesapeake Bay, 2) mapping of submerged aquatic vegetation in the Bay, 3) detection of vegetation stress related to Superfund sites at the Yorktown Naval Weapons Station, and 4) wetland species analysis in the York River vicinity. In support of this project, three lines of AVIRIS data were collected during the Wallops Island deployment on 17 August 1997. The remote sensing payload included AVIRIS, MODIS Airborne Simulator and an RC-10 color infrared film camera. The AVIRIS data were delivered to Ames from the JPL AVIRIS Data Facility, on 29 September 1997. Quicklook images indicate nominal data acquisition, and at the current time an atmospheric correction is being applied. Water constituent analysis of the Bay is our highest priority based on EPA interest and available collateral data, both from the surface and from other remote sensing instruments. Constituents of interest include suspended sediments, chlorophyll-a and accessory pigments, Analysis steps will include: verification of data quality, location of study sites in imagery, incorporation of relevant field data from EPA and other Chesapeake Bay cooperators, processing of imagery to show phenomenon of interest, verification of results with cooperators. By 1st quarter CY98 we plan to circulate initial results to NASA and EPA management for review. In the longer term we will finalize documentation, prepare results for publication, and complete any needed technology transfer to EPA remote sensing personnel.

  14. Effect of joint spacing and joint dip on the stress distribution around tunnels using different numerical methods

    NASA Astrophysics Data System (ADS)

    Nikadat, Nooraddin; Fatehi Marji, Mohammad; Rahmannejad, Reza; Yarahmadi Bafghi, Alireza

    2016-11-01

    Different conditions may affect the stability of tunnels by the geometry (spacing and orientation) of joints in the surrounded rock mass. In this study, by comparing the results obtained by the three novel numerical methods i.e. finite element method (Phase2), discrete element method (UDEC) and indirect boundary element method (TFSDDM), the effects of joint spacing and joint dips on the stress distribution around rock tunnels are numerically studied. These comparisons indicate the validity of the stress analyses around circular rock tunnels. These analyses also reveal that for a semi-continuous environment, boundary element method gives more accurate results compared to the results of finite element and distinct element methods. In the indirect boundary element method, the displacements due to joints of different spacing and dips are estimated by using displacement discontinuity (DD) formulations and the total stress distribution around the tunnel are obtained by using fictitious stress (FS) formulations.

  15. Joint attention in Down syndrome: A meta-analysis.

    PubMed

    Hahn, Laura J; Loveall, Susan J; Savoy, Madison T; Neumann, Allie M; Ikuta, Toshikazu

    2018-07-01

    Some studies have indicated that joint attention may be a relative strength in Down syndrome (DS), but other studies have not. To conduct a meta-analysis of joint attention in DS to more conclusively determine if this is a relative strength or weakness when compared to children with typical development (TD), developmental disabilities (DD), and autism spectrum disorder (ASD). Journal articles published before September 13, 2016, were identified by using the search terms "Down syndrome" and "joint attention" or "coordinating attention". Identified studies were reviewed and coded for inclusion criteria, descriptive information, and outcome variables. Eleven studies (553 participants) met inclusion criteria. Children with DS showed similar joint attention as TD children and higher joint attention than children with DD and ASD. Meta-regression revealed a significant association between age and joint attention effect sizes in the DS vs. TD contrast. Joint attention appears to not be a weakness for children with DS, but may be commensurate with developmental level. Joint attention may be a relative strength in comparison to other skills associated with the DS behavioral phenotype. Early interventions for children with DS may benefit from leveraging joint attention skills. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Influence of altered gait patterns on the hip joint contact forces.

    PubMed

    Carriero, Alessandra; Zavatsky, Amy; Stebbins, Julie; Theologis, Tim; Lenaerts, Gerlinde; Jonkers, Ilse; Shefelbine, Sandra J

    2014-01-01

    Children who exhibit gait deviations often present a range of bone deformities, particularly at the proximal femur. Altered gait may affect bone growth and lead to deformities by exerting abnormal stresses on the developing bones. The objective of this study was to calculate variations in the hip joint contact forces with different gait patterns. Muscle and hip joint contact forces of four children with different walking characteristics were calculated using an inverse dynamic analysis and a static optimisation algorithm. Kinematic and kinetic analyses were based on a generic musculoskeletal model scaled down to accommodate the dimensions of each child. Results showed that for all the children with altered gaits both the orientation and magnitude of the hip joint contact force deviated from normal. The child with the most severe gait deviations had hip joint contact forces 30% greater than normal, most likely due to the increase in muscle forces required to sustain his crouched stance. Determining how altered gait affects joint loading may help in planning treatment strategies to preserve correct loading on the bone from a young age.

  17. Effect of Thread and Rotating Speed on Material Flow Behavior and Mechanical Properties of Friction Stir Lap Welding Joints

    NASA Astrophysics Data System (ADS)

    Ji, Shude; Li, Zhengwei; Zhou, Zhenlu; Wu, Baosheng

    2017-10-01

    This study focused on the effects of thread on hook and cold lap formation, lap shear property and impact toughness of alclad 2024-T4 friction stir lap welding (FSLW) joints. Except the traditional threaded pin tool (TR-tool), three new tools with different thread locations and orientations were designed. Results showed that thread significantly affected hook, cold lap morphologies and lap shear properties. The tool with tip-threaded pin (T-tool) fabricated joint with flat hook and cold lap, which resulted in shear fracture mode. The tools with bottom-threaded pin (B-tool) eliminated the hook. The tool with reverse-threaded pin (R-tool) widened the stir zone width. When using configuration A, the joints fabricated by the three new tools showed higher failure loads than the joint fabricated by the TR-tool. The joint using the T-tool owned the optimum impact toughness. This study demonstrated the significance of thread during FSLW and provided a reference to optimize tool geometry.

  18. Effects of free-range and confined housing on joint health in a herd of fattening pigs.

    PubMed

    Etterlin, Pernille Engelsen; Ytrehus, Bjørnar; Lundeheim, Nils; Heldmer, Eva; Österberg, Julia; Ekman, Stina

    2014-09-11

    Free-range housing, in which pigs have access to both indoor and outdoor areas, is mandatory in organic pig production in Europe, but little is known about the effects of this housing on joint health in pigs. A high level of joint condemnations at slaughter has been reported in organic free-range pigs in Sweden, compared with pigs raised in conventional confined housing. We hypothesised that biomechanical forces imposed on the joints of pigs that range freely promote the development of osteochondrosis and lead to joint condemnation. We compared the prevalence of osteochondrosis and other joint lesions (e.g. arthritis, traumatic) in the elbow and hock joints of 91 crossbred Hampshire (Yorkshire × Landrace) fattening pigs that were housed in a free-range indoor/outdoor system with that in 45 pigs housed in confined indoor pens. A larger proportion of free-range than confined pigs had osteochondrosis in the elbow joints (69 vs. 50%, p < 0.05), and a higher proportion of these joints in free-range pigs showed moderate or severe lesions (33 vs. 16%, p < 0.05). The free-range pigs also showed a higher prevalence of osteochondrosis in the hock joints (83 vs. 62%, p < 0.05) and a larger proportion of these joints had moderate or severe lesions (69 vs. 33%, p < 0.001). At slaughter, 4.2% of the free-range pigs had condemned joints, all of which showed severe osteochondrosis, while no joints of confined pigs were condemned. In this experiment the prevalence of osteochondrosis in the elbow and the hock was higher, and lesions were more severe, in free-range than in confined pigs, suggesting that free-range housing increases the risk of acquiring osteochondrosis. Increased biomechanical stress to vulnerable joint structures may be the mechanism behind this effect, however more studies are needed to verify these results. This study suggests that modification of housing, and breeding for joints that are more adapted to free-range movement may be needed in free-range pig

  19. Virtual Passive Controller for Robot Systems Using Joint Torque Sensors

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.; Juang, Jer-Nan

    1997-01-01

    This paper presents a control method based on virtual passive dynamic control that will stabilize a robot manipulator using joint torque sensors and a simple joint model. The method does not require joint position or velocity feedback for stabilization. The proposed control method is stable in the sense of Lyaponov. The control method was implemented on several joints of a laboratory robot. The controller showed good stability robustness to system parameter error and to the exclusion of nonlinear dynamic effects on the joints. The controller enhanced position tracking performance and, in the absence of position control, dissipated joint energy.

  20. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    PubMed

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Lower limb joint work and joint work contribution during downhill and uphill walking at different inclinations.

    PubMed

    Alexander, Nathalie; Strutzenberger, Gerda; Ameshofer, Lisa Maria; Schwameder, Hermann

    2017-08-16

    Work performance and individual joint contribution to total work are important information for creating training protocols, but were not assessed so far for sloped walking. Therefore, the purpose of this study was to analyze lower limb joint work and joint contribution of the hip, knee and ankle to total lower limb work during sloped walking in a healthy population. Eighteen male participants (27.0±4.7yrs, 1.80±0.05m, 74.5±8.2kg) walked on an instrumented ramp at inclination angles of 0°, ±6°, ±12° and ±18° at 1.1m/s. Kinematic and kinetic data were captured using a motion-capture system (Vicon) and two force plates (AMTI). Joint power curves, joint work (positive, negative, absolute) and each joint's contribution to total lower limb work were analyzed throughout the stance phase using an ANOVA with repeated measures. With increasing inclination positive joint work increased for the ankle and hip joint and in total during uphill walking. Negative joint work increased for each joint and in total work during downhill walking. Absolute work was increased during both uphill (all joints) and downhill (ankle & knee) walking. Knee joint contribution to total negative and absolute work increased during downhill walking while hip and ankle contributions decreased. This study identified, that, when switching from level to a 6° and from 6° to a 12° inclination the gain of individual joint work is more pronounced compared to switching from 12° to an 18° inclination. The results might be used for training recommendations and specific training intervention with respect to sloped walking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Effect of shoe inserts on kinematics, center of pressure, and leg joint moments during running.

    PubMed

    Nigg, Benno M; Stergiou, Pro; Cole, Gerald; Stefanyshyn, Darren; Mündermann, Anne; Humble, Neil

    2003-02-01

    The purposes of this project were to assess the effect of four different shoe inserts on the path of the center of pressure (COP), to quantify the effect of these inserts on selected knee joint moments during running, and to assess the potential of COP data to predict the effects of inserts/orthotics on knee joint moments. Kinematics for the lower extremities, resultant ankle and knee joint moments, and the path of the COP were collected from the right foot of 15 male subjects while running heel-toe with five different shoe inserts (full or half with 4.5-mm postings). Individual movement changes with respect to the neutral insert condition were typically small and not systematic. Significant changes for the path of the COP were registered only for the full lateral insert condition with an average shift toward the lateral side. The mediolateral shift of the COP was not consistent for the full medial and the two half-shoe inserts. The subject-specific reactions to the inserts' intervention in the corresponding knee joint moments were typically not consistent. Compared with the neutral insert condition, subjects showed increases or decreases of the knee joint moments. The correlation between the individual COP shifts and the resultant knee joint moment was generally small. The results of this study showed that subject-specific reactions to the tested inserts were often not as expected. Additionally, reactions were not consistent between the subjects. This result suggests that the prescription of inserts and/or orthotics is a difficult task and that methods must be developed to test and assess these effects. Such methods, however, are not currently available.

  3. Gun Shows and Gun Violence: Fatally Flawed Study Yields Misleading Results

    PubMed Central

    Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A.

    2010-01-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled “The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas” outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors’ prior research. The study should not be used as evidence in formulating gun policy. PMID:20724672

  4. Gun shows and gun violence: fatally flawed study yields misleading results.

    PubMed

    Wintemute, Garen J; Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A

    2010-10-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled "The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas" outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors' prior research. The study should not be used as evidence in formulating gun policy.

  5. Kinetic and kinematic evaluation of the ankle joint after achilles tendon reconstruction with free semitendinosus tendon graft: preliminary results.

    PubMed

    Lins, Carolina; Ninomya, André Felipe; Bittar, Cintia Kelly; de Carvalho, Antônio Egydio; Cliquet, Alberto

    2013-03-01

    Chronic rupture of the Achilles tendon (AT) is a surgical challenge and has effects on the gait. The purpose of this study was to evaluate the kinetic and kinematic parameters of the ankle joint in patients with AT rupture operated using a free semitendinosus tendon graft. Thirteen patients were analyzed 6 and 12 months after surgery in a force platform, while the movements were recorded by six infrared cameras. The kinematic variables analyzed included speed, cadence, step length, percentage of stance phase, and range of movement (ROM) of the ankle joint in the sagittal and frontal planes. Kinetic data were obtained by joint movement in different phases of the gait cycle. Functional assessment was performed using the American Orthopaedic Foot and Ankle Society (AOFAS) score. The patients showed a significant increase (P = 0.0215) in AOFAS from 68.5 (±18.7) to 85.2 (±18.0). Speed, cadence, and length of step of the four groups (1A, 1B, 2A, 2B) were lower than the control group (group 3), and the percentage in stance phase was higher for the nonoperated foot 6-month group (1B) compared to the control group (group 3). For the kinematic data, the ROM of the ankle in stance phase increased from 6 to 12 months showing an effect of time between four groups (1A, 1B, 2A, 2B). During swing phase, the ankle ROM was lower in the operated side (effect of side, P = 0.0255) and groups 1A and 2A demonstrated statistical differences when compared with the control group (group 3) (P = 0.0240 and P = 0.0414, respectively). ROM of inversion and eversion presented effect of time among the same groups (P = 0.0059) cited before. There were no differences in kinetic data between groups. This study showed close proximity between the control group and the operated group. Furthermore, improvement was shown when comparing the 6 and 12 months postsurgery periods. The surgical procedure is therefore helpful for the patient and few changes were present in gait and ankle

  6. Joint Coordination and Muscle Activities of Ballet Dancers During Tiptoe Standing.

    PubMed

    Tanabe, Hiroko; Fujii, Keisuke; Kouzaki, Motoki

    2017-01-01

    We aimed to investigate joint coordination of lower limbs in dancers during tiptoe standing and the relationship between joint coordination and muscle coactivation. Seven female ballet dancers performed tiptoe standing with six leg positions (fi e classical dance positions and one modern dance position) for 10 s. The kinematic data of the metatarsophalangeal (MP), ankle, knee, and hip joints was collected, and surface electromyography (EMG) of over 13 lower limb muscles was conducted. Principal component analysis was performed to determine joint coordination. MP-ankle and ankle-knee had in-phase coordination, whereas knee-hip showed anti-phase coordination in the sagittal plane. In addition, most EMG-EMG coherence around the MP and ankle joints was significant up to 50 Hz when these two joints swayed with in-phase. This suggests that different joint coordination patterns are associated with neural processing related to different muscle coactivation patterns. In conclusion, ballet dancers showed in-phase coordination from the MP to knee joints, which was associated with muscle coactivation to a higher frequency domain (up to 50 Hz) in comparison with anti-phase coordination.

  7. Comparative effectiveness of open versus minimally invasive sacroiliac joint fusion.

    PubMed

    Ledonio, Charles Gt; Polly, David W; Swiontkowski, Marc F; Cummings, John T

    2014-01-01

    The mainstay of sacroiliac joint disruption/degenerative sacroiliitis therapy has been nonoperative management. This nonoperative management often includes a regimen of physical therapy, chiropractic treatment, therapeutic injections, and possibly radiofrequency ablation at the discretion of the treating physician. When these clinical treatments fail, sacroiliac joint fusion has been recommended as the standard treatment. Open and minimally invasive (MIS) surgical techniques are typical procedures. This study aims to compare the perioperative measures and Oswestry Disability Index (ODI) outcomes associated with each of these techniques. A comparative retrospective chart review of patients with sacroiliac joint fusion and a minimum of 1 year of follow-up was performed. Perioperative measures and ODI scores were compared using the Fisher's exact test and two nonparametric tests, ie, the Mann-Whitney U test and the Wilcoxon signed-rank test. The results are presented as percent or median with range, as appropriate. Forty-nine patients from two institutions underwent sacroiliac joint fusion between 2006 and 2012. Ten patients were excluded because of incomplete data, leaving 39 evaluable patients, of whom 22 underwent open and 17 underwent MIS sacroiliac joint fusion. The MIS group was significantly older (median age 66 [39-82] years) than the open group (median age 51 [34-74] years). Surgical time and hospital stay were significantly shorter in the MIS group than in the open group. Preoperative ODI was significantly greater in the open group (median 64 [44-78]) than in the MIS group (median 53 [14-84]). Postoperative improvement in ODI was statistically significant within and between groups, with MIS resulting in greater improvement. The open and MIS sacroiliac joint fusion techniques resulted in statistically and clinically significant improvement for patients with degenerative sacroiliitis refractory to nonoperative management. However, the number of patients

  8. Functional outcome from sacroiliac joint prolotherapy in patients with sacroiliac joint instability.

    PubMed

    Hoffman, Martin D; Agnish, Vikram

    2018-04-01

    Examine the effectiveness of sacroiliac (SI) joint prolotherapy for SI joint instability, and characterize the patients most likely to benefit from this treatment. Retrospective cohort study. Department of Veterans Affairs outpatient physical medicine clinic. Patients referred for low back pain and diagnosed with SI joint instability received a series of three SI joint prolotherapy injections (15% dextrose in lidocaine) at approximately a one-month interval. The outcome of those completing treatment was retrospectively examined, and characteristics were compared between those with at least a minimum clinically important improvement and those without improvement. Patients completed the Oswestry Disability Index (ODI) before treatment was initiated, immediately preceding each prolotherapy injection, and at 3-4 month follow-up. Of 103 treated patients returning for post-treatment follow-up at a median of 117 days, 24 (23%) showed a minimum clinically important improvement despite a median of 2 years with low back pain and a mean (±SD) pre-intervention ODI of 54 ± 15 points. Much of the improvement was evident after the initial prolotherapy injection, and a 15-point improvement in ODI prior to the second prolotherapy injection had a sensitivity of 92% and specificity of 80% for determining which patients would improve. A satisfactory proportion of patients with symptomatic SI joint instability as an etiology of low back pain can have clinically meaningful functional gains with prolotherapy treatment. The patients who are not likely to improve with prolotherapy are generally evident by lack of improvement following the initial prolotherapy injection. Published by Elsevier Ltd.

  9. Exercise may decrease further destruction in the adult haemophilic joint.

    PubMed

    Harris, S; Boggio, L N

    2006-05-01

    The effect of exercise on adult haemophilic joints was investigated. Forty-six subjects with existing joint disease were evaluated and range of motion (ROM) in joints was measured. The effect of exercise of large joint ROM in haemophilia was evaluated by comparing the ranges of motion in subjects who exercised at least three times weekly against those subjects who did not exercise. The exercise group showed improvement in the majority of joint ranges of motion compared with the non-exercise group (P = 0.003). Thus regular exercise may help reduce further destruction in haemophilic joints by strengthening muscle ligaments and tendons surrounding the joint thereby protecting them from damage caused by recurrent haemarthrotic events.

  10. The Cultural Context of Learning in International Joint Ventures.

    ERIC Educational Resources Information Center

    Liu, Shimin; Vince, Russ

    1999-01-01

    A study of Chinese-Western joint business ventures showed that cultural context and different modes of managing and organizing must be considered. Successful joint ventures involve a process of collective, two-way learning. (SK)

  11. Temporo mandibular joint ankylosis.

    PubMed

    Vasconcelos, Belmiro Cavalcanti do Egito; Porto, Gabriela Granja; Bessa-Nogueira, Ricardo Viana

    2008-01-01

    Ankylosis may be defined as joint surfaces fusion. The treatment of temporomandibular joint ankylosis poses a significant challenge because of the high recurrence rate. The aim of this study is to report six cases treated by joint reconstruction, evaluate the results of these surgeries and review the literature. The sample in this retrospective study was obtained from the records of the university hospital, patients who had to undergo ankylosis treatment by alloplastic or autogenous graft between March 2001 and October 2005. Pre - and post-operative assessment included a throughout history and physical examination to determine the cause of ankylosis, the Maximum mouth opening (MMO), etiology and type of ankylosis, recurrence rate and presence of facial nerve paralysis. The mean MMO in the pre-operative period was 9.6 mm (0 mm to 17 mm) and in the post-operative period it was of 31.33 mm (14 mm to 41 mm), there was no facial nerve paralysis and there was recurrence in just one case. The joint reconstruction with alloplastic or autogenous grafts for the ankylosis treatment proved to be efficient in relation to the post-operative MMO, recurrence and joint function.

  12. Experiments and kinematics analysis of a hand rehabilitation exoskeleton with circuitous joints.

    PubMed

    Zhang, Fuhai; Fu, Yili; Zhang, Qinchao; Wang, Shuguo

    2015-01-01

    Aiming at the hand rehabilitation of stroke patients, a wearable hand exoskeleton with circuitous joint is proposed. The circuitous joint adopts the symmetric pinion and rack mechanism (SPRM) with the parallel mechanism. The exoskeleton finger is a serial mechanism composed of three closed-chain SPRM joints in series. The kinematic equations of the open chain of the finger and the closed chains of the SPRM joints were built to analyze the kinematics of the hand rehabilitation exoskeleton. The experimental setup of the hand rehabilitation exoskeleton was built and the continuous passive motion (CPM) rehabilitation experiment and the test of human-robot interaction force measurement were conducted. Experiment results show that the mechanical design of the hand rehabilitation robot is reasonable and that the kinematic analysis is correct, thus the exoskeleton can be used for the hand rehabilitation of stroke patients.

  13. Analysis on the Fracture of Al-Cu Dissimilar Materials Friction Stir Welding Lap Joint

    NASA Astrophysics Data System (ADS)

    Sun, Hongyu; Zhou, Qi; Zhu, Jun; Peng, Yong

    2017-12-01

    Friction stir welding (FWS) is regarded as a more plausible alternative to other welding methods for Al-Cu dissimilar joining. However, the structure of an FSW joint is different from others. In this study, lap joints of 6061 aluminum alloy and commercially pure copper were produced by FSW, and the effects of rotation rate on macromorphology, microstructure and mechanical properties were investigated. In addition, a fracture J integral model was used to analyze the effect of microstructure on the mechanical properties. The results revealed that the macrodefect-free joints were obtained at a feed rate of 150 mm/min and 1100 rpm and that the failure load of the joint reached as high as 4.57 kN and only reached 2.91 kN for the 900 rpm, where tunnel defects were identified. Particle-rich zones composed of Cu particles dispersed in an Al matrix, and "Flow tracks" were observed by the EDS. The J integral results showed that the microdefects on the advancing side cause serious stress concentration compared with the microdefects located on the Al-Cu interface, resulting in the fracture of the joints.

  14. Debonding of Stitched Composite Joints: Testing and Analysis

    NASA Technical Reports Server (NTRS)

    Glaessgen, E. H.; Raju, I. S.; Poe, C. C., Jr.

    1999-01-01

    The effect of stitches on the failure of a single lap joint configuration was determined in a combined experimental and analytical study. The experimental study was conducted to determine debond growth under static monotonic loading. The stitches were shown to delay the initiation ofthe debond and provide load transfer beyond the load necessary to completely debond the stitched lap joint. The strain energy release rates at the debond front were calculated using a finite element-based technique. Models of the unstitched configuration showed significant values of modes I and II across the width of the joint and showed that mode III is zero at the centerline but increases near the free edge. Models of the stitched configuration showed that the stitches effectively reduced mode I to zero, but had less of an effect on modes II and III.

  15. Effect of stress concentration on the fatigue strength of A7N01S-T5 welded joints

    NASA Astrophysics Data System (ADS)

    Zhang, Mingyue; Gou, Guoqing; Hang, Zongqiu; Chen, Hui

    2017-07-01

    Stress concentration is a key factor that affects the fatigue strength of welded joints. In this study, the fatigue strengths of butt joints with and without the weld reinforcement were tested to quantify the effect of stress concentration. The fatigue strength of the welded joints was measured with a high-frequency fatigue machine. The P-S-N curves were drawn under different confidence levels and failure probabilities. The results show that butt joints with the weld reinforcement have much lower fatigue strength than joints without the weld reinforcement. Therefore, stress concentration introduced by the weld reinforcement should be controlled.

  16. Conarticular congruence of the hominoid subtalar joint complex with implications for joint function in Plio-Pleistocene hominins.

    PubMed

    Prang, Thomas C

    2016-07-01

    The purpose of this study is to test the hypothesis that conarticular surfaces areas and curvatures are correlates of mobility at the hominoid talocalcaneal and talonavicular joints. Articular surface areas and curvatures of the talonavicular, anterior talocalcaneal, and posterior talocalcaneal joints were quantified using a total of 425 three-dimensional surface models of extant hominoid and fossil hominin tali, calcanei, and naviculars. Quadric surface fitting was used to calculate curvatures, pairwise comparisons were used to evaluate statistical differences between taxa, and regression was used to test for the effects of allometry. Pairwise comparisons show that the distributions of values for joint curvature indices follow the predicted arboreal-terrestrial morphocline in hominoid primates with no effect of body mass (PGLS p > 0.05). OH 8 (Homo habilis) and LB 1 (Homo floresiensis) can be accommodated within the range of human variation for the talonavicular joint, whereas MH2 (Australopithecus sediba) falls within the ranges of variation for Pan troglodytes and Gorilla gorilla in measures of posterior talocalcaneal joint congruity. Joint curvature indices are better discriminators than joint surface area indices, which may reflect a greater contribution of rotation, rather than translation, to joint movement in plantigrade taxa due to discrepancies in conarticular congruence and the "convex-concave" rule. The pattern of joint congruence in Au. sediba contributes to other data on the foot and ankle suggesting that the lateral side of the foot was more mobile than the medial side, which is consistent with suggestions of increased medial weight transfer associated with hyperpronation. Am J Phys Anthropol 160:446-457, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    PubMed

    Jiang, Shangyuan; Gan, Rong Z

    2018-04-01

    The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the dynamic properties of the human ISJ measured in eight samples using a dynamic mechanical analyzer (DMA) for frequencies from 1 to 80 Hz at three temperatures of 5, 25 and 37 °C. The frequency-temperature superposition (FTS) principle was used to extrapolate the results to 8 kHz. The complex modulus of ISJ was measured with a mean storage modulus of 1.14 MPa at 1 Hz that increased to 3.01 MPa at 8 kHz, and a loss modulus that increased from 0.07 to 0.47 MPa. A 3-dimensional finite element (FE) model consisting of the articular cartilage, joint capsule and synovial fluid was then constructed to derive mechanical properties of ISJ components by matching the model results to experimental data. Modeling results showed that mechanical properties of the joint capsule and synovial fluid affected the dynamic behavior of the joint. This study contributes to a better understanding of the structure-function relationship of the ISJ for sound transmission. Copyright © 2018. Published by Elsevier Ltd.

  18. Knee joint mobilization reduces secondary mechanical hyperalgesia induced by capsaicin injection into the ankle joint.

    PubMed

    Sluka, K A; Wright, A

    2001-01-01

    Joint mobilization is a treatment approach commonly used by physical therapists for the management of a variety of painful conditions. However, the clinical effectiveness when compared to placebo and the neurophysiological mechanism of action are not known. The purpose of this study was to establish that application of a manual therapy technique will produce antihyperalgesia in an animal model of joint inflammation and that the antihyperalgesia produced by joint mobilization depends on the time of treatment application. Capsaicin (0.2%, 50 microl) was injected into the lateral aspect of the left ankle joint and mechanical withdrawal threshold assessed before and after capsaicin injection in Sprague-Dawley rats. Joint mobilization of the ipsilateral knee joint was performed 2 h after capsaicin injection for a total of 3 min, 9 min or 15 min under halothane anaesthesia. Control groups included animals that received halothane for the same time as the group that received joint mobilization and those whose limbs were held for the same duration as the mobilization (no halothane). Capsaicin resulted in a decreased mechanical withdrawal threshold by 2 h after injection that was maintained through 4 h. Both 9 and 15 min of mobilization, but not 3 min of mobilization, increased the withdrawal threshold to mechanical stimuli to baseline values when compared with control groups. The antihyperalgesic effect of joint mobilization lasted 30 min. Thus, joint mobilization (9 or 15 min duration) produces a significant reversal of secondary mechanical hyperalgesia induced by intra-articular injection of capsaicin. Copyright 2001 European Federation of Chapters of the International Association for the Study of Pain.

  19. Joint Laxity in Preschool Children Born Preterm.

    PubMed

    Romeo, Domenico M; Velli, Chiara; Lucibello, Simona; Ferrantini, Gloria; Leo, Giuseppina; Brogna, Claudia; Cota, Francesco; Ricci, Daniela; Gallini, Francesca; Romagnoli, Costantino; Vento, Giovanni; Mercuri, Eugenio

    2018-06-01

    To evaluate the prevalence of joint laxity in children born preterm assessed in the first 2 years, the relationship between joint laxity and motor performance at preschool age, and possible changes over time in a subgroup of children followed longitudinally. The revised scale of Beighton Score was used to evaluate joint laxity in a population of 132 preschool children born preterm between 24 and 32 weeks of gestational age. All were assessed for joint laxity between 12 and 24 months of age. Children also performed the Movement Assessment Battery for Children-Second Edition between the age of 3 years and 6 months and 4 years; the age at onset of independent walking also was recorded. The total Beighton Score ranged between 0 and 8. Twenty percent of the cohort showed joint laxity. No differences related to sex or gestational age were observed. Children born preterm with joint laxity achieved later independent walking and achieved lower scores on Movement Assessment Battery for Children-Second Edition than those without joint laxity. In 76 children born preterm, an assessment for joint laxity was repeated once between 25 and 36 months and again after >36 months. No statistically significant difference was observed between the 3 assessments. The Beighton Score can be used to assess generalized joint laxity in children born preterm. As the presence of joint laxity influenced motor competences, the possibility to early identify these infants in the first 2 years is of interest to benefit from early intervention and potentially improve gross motor skills and coordination. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Fatigue Damage Monitoring of a Composite Step Lap Joint Using Distributed Optical Fibre Sensors

    PubMed Central

    Wong, Leslie; Chowdhury, Nabil; Wang, John; Chiu, Wing Kong; Kodikara, Jayantha

    2016-01-01

    Over the past few decades, there has been a considerable interest in the use of distributed optical fibre sensors (DOFS) for structural health monitoring of composite structures. In aerospace-related work, health monitoring of the adhesive joints of composites has become more significant, as they can suffer from cracking and delamination, which can have a significant impact on the integrity of the joint. In this paper, a swept-wavelength interferometry (SWI) based DOFS technique is used to monitor the fatigue in a flush step lap joint composite structure. The presented results will show the potential application of distributed optical fibre sensor for damage detection, as well as monitoring the fatigue crack growth along the bondline of a step lap joint composite structure. The results confirmed that a distributed optical fibre sensor is able to enhance the detection of localised damage in a structure. PMID:28773496

  1. Acquisition of joint attention by olive baboons gesturing toward humans.

    PubMed

    Lamaury, Augustine; Cochet, Hélène; Bourjade, Marie

    2017-07-10

    Joint attention is a core ability of human social cognition which broadly refers to the coordination of attention with both the presence and activity of social partners. In both human and non-human primates, joint attention can be assessed from behaviour; gestures and gaze alternation between the partner and a distal object are standard behavioural manifestations of joint attention. Here we examined the acquisition of joint attention in olive baboons as a function of their individual experience of a human partner's attentional states during training regimes. Eleven olive baboons (Papio anubis) were observed during their training to perform food-requesting gestures, which occurred either by (1) a human facing them (face condition), or (2) by a human positioned in profile who never turned to them (profile condition). We found neither gestures nor gaze alternation were present at the start of the training but rather developed over the training period. Only baboons in the face condition showed an increase in the number of gaze alternations, and their gaze pattern progressively shifted to a coordinated sequence in which gazes and gestures were coordinated in time. In contrast, baboons trained by a human in profile showed significantly less coordination of gazes with gestures but still learned to request food with their gestures. These results suggest that the partner's social attention plays an important role in the acquisition of visual joint attention and, to a lesser extent, in gesture learning in baboons. Interspecific interactions appear to offer rich opportunities to manipulate and thus identify the social contexts in which socio-communicative skills develop.

  2. Gait changes after using a temporomandibular joint exerciser in patients who underwent lower limb joint surgery

    PubMed Central

    Chung, Gu-Young; Choi, Geun-Seok; Shin, Ki-Young; Park, Joon-Soo

    2016-01-01

    [Purpose] The improvements in gait of the patients with lower limb disease who used a temporomandibular joint (TMJ) exerciser were verified. [Subjects and Methods] Eleven subjects were included. Their mean age was 53.2 years. The lower limb joint angles before and after using the TMJ exerciser were measured using a gait analyzer. Before the gait experiment, the TMJ exerciser setting process and one-leg stance balance test (OLST) were repeated until the balance maintenance time improved. [Results] Because of the OLST, the mean change in the body center point after the subjects used the exerciser improved from 5.76 mm to 4.20 mm. When the TMJ exerciser was used, the joint angle range of the subjects approached that of the normal individuals. [Conclusion] According to the gait experiments, the angles of the subjects’ hips, knees, and ankle joints approached to those of the normal individuals after the subjects used the TMJ exerciser; however, the results did not completely match. The changes in the hip, knee, and ankle joint angles were statistically significant, which confirm the usefulness of the TMJ exerciser. PMID:27313377

  3. Cerebellar ataxia: abnormal control of interaction torques across multiple joints.

    PubMed

    Bastian, A J; Martin, T A; Keating, J G; Thach, W T

    1996-07-01

    1. We studied seven subjects with cerebellar lesions and seven control subjects as they made reaching movements in the sagittal plane to a target directly in front of them. Reaches were made under three different conditions: 1) "slow-accurate," 2) "fast-accurate," and 3) "fast as possible." All subjects were videotaped moving in a sagittal plane with markers on the index finger, wrist, elbow, and shoulder. Marker positions were digitized and then used to calculate joint angles. For each of the shoulder, elbow and wrist joints, inverse dynamics equations based on a three-segment limb model were used to estimate the net torque (sum of components) and each of the component torques. The component torques consisted of the torque due to gravity, the dynamic interaction torques induced passively by the movement of the adjacent joint, and the torque produced by the muscles and passive tissue elements (sometimes called "residual" torque). 2. A kinematic analysis of the movement trajectory and the change in joint angles showed that the reaches of subjects with cerebellar lesions were abnormal compared with reaches of control subjects. In both the slow-accurate and fast-accurate conditions the cerebellar subjects made abnormally curved wrist paths; the curvature was greater in the slow-accurate condition. During the slow-accurate condition, cerebellar subjects showed target undershoot and tended to move one joint at a time (decomposition). During the fast-accurate reaches, the cerebellar subjects showed target overshoot. Additionally, in the fast-accurate condition, cerebellar subjects moved the joints at abnormal rates relative to one another, but the movements were less decomposed. Only three subjects were tested in the fast as possible condition; this condition was analyzed only to determine maximal reaching speeds of subjects with cerebellar lesions. Cerebellar subjects moved more slowly than controls in all three conditions. 3. A kinetic analysis of torques generated at

  4. Some new evidence on human joint lubrication.

    PubMed Central

    Unsworth, A; Dowson, D; Wright, V

    1975-01-01

    Theoretical consideration has been given to the use of pendulum machines which are used to examine the frictional properties of human joints by incorporating them as fulcra. As a result, a new type of pendulum machine has been built which incorporates the facility to apply sudden loads to the joint on starting the swinging motion, and also the ability to measure directly the frictional torque experienced by the joint. The results obtained from natural hip joints indicate the presence of squeeze film lubrication under conditions of sudden loading of a joint. In addition, a self-generated fluid film process was observed at low loads while at higher loads boundary lubrication appeared to be important. These results have been used to describe the lubrication regimens occurring in a normal activity such as walking. A single experiment carried out on a hip from a patient suffering from severe rheumatoid arthritis has also been reported and the frictional resistance was seen to be increased fifteenfold compared to a normal hip. Images PMID:1190847

  5. Limited distal clavicle excision of acromioclavicular joint osteoarthritis.

    PubMed

    Gokkus, K; Saylik, M; Atmaca, H; Sagtas, E; Aydin, A T

    2016-05-01

    Resection of the distal aspect of clavicle has a well-documented treatment modality in case of acromioclavicular joint osteoarthritis resistant to conservative treatment. Limited (mean ∼0.5cm distal end of clavicle resection) distal clavicle excision of A-C joint arthritis in cases resistant to conservative treatment may reduce the pain and improve the shoulder function. In this study, we retrospectively evaluated the results of limited distal clavicle excision of acromioclavicular joint osteoarthritis resistant to conservative treatment. All patients were evaluated by using the Visual Analogue Scale (VAS) and UCLA shoulder rating scale (University of California Los Angeles), either before surgery or final follow-up period for pain and functional results, respectively. A total of 110 patients (48 male, 62 female) with AC joint arthritis, treated between the years of 2008-2012, were retrospectively analyzed. A total of 30 patients (12 male, 18 female) who failed to show improvement with conservative treatment underwent limited surgical open excision of distal clavicle. The mean age of the study population was 52.5±1.2 years. The mean follow-up period was 27±1.3 months. The mean preoperative VAS score was 83.6±5.58 (range, 70-90) while mean VAS was 26.6±9.3 (range, 10-50) at the final follow-up. There was a statistically significant difference between pre- and postoperative VAS scores in patients who had treated by surgical approach (P<0.001). The mean UCLA score of the patients increased postoperatively from 11.5 (range, 9-14) to 29.2 (range, 27-32) at the final follow-up. There was a statistically significant difference between the two time periods with respect to UCLA scores (P<0.001). In patients with AC osteoarthritis resistant to conservative therapy, the hypothesized limited clavicle excision (mean ∼0.5cm distal end of clavicle resection with preserving coracoclavicular ligaments and inferior capsule) reduced the pain and improved the shoulder function

  6. Joint Instability and Osteoarthritis

    PubMed Central

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA. PMID:25741184

  7. Joint instability and osteoarthritis.

    PubMed

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  8. Evaluation of Rock Joint Coefficients

    NASA Astrophysics Data System (ADS)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.

  9. A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints

    PubMed Central

    Chyr, Anthony; Qiu, Mingfeng; Speltz, Jared; Jacobsen, Ronald L.; Sanders, Anthony P.; Raeymaekers, Bart

    2014-01-01

    More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily as a result of polyethylene wear and wear debris incited disease. The current engineering paradigm to increase the longevity of prosthetic hip joints is to improve the mechanical properties of the polyethylene component, and to manufacture ultra-smooth articulating surfaces. In contrast, we show that adding a patterned microtexture to the ultra-smooth CoCr femoral head reduces friction when articulating with the polyethylene acetabular liner. The microtexture increases the load-carrying capacity and the thickness of the joint lubricant film, which reduces contact between the articulating surfaces. As a result, friction and wear is reduced. We have used a lubrication model to design the geometry of the patterned microtexture, and experimentally demonstrate reduced friction for the microtextured compared to conventional smooth surrogate prosthetic hip joints. PMID:25013240

  10. Comparative effectiveness of open versus minimally invasive sacroiliac joint fusion

    PubMed Central

    Ledonio, Charles GT; Polly, David W; Swiontkowski, Marc F; Cummings, John T

    2014-01-01

    Background The mainstay of sacroiliac joint disruption/degenerative sacroiliitis therapy has been nonoperative management. This nonoperative management often includes a regimen of physical therapy, chiropractic treatment, therapeutic injections, and possibly radiofrequency ablation at the discretion of the treating physician. When these clinical treatments fail, sacroiliac joint fusion has been recommended as the standard treatment. Open and minimally invasive (MIS) surgical techniques are typical procedures. This study aims to compare the perioperative measures and Oswestry Disability Index (ODI) outcomes associated with each of these techniques. Methods A comparative retrospective chart review of patients with sacroiliac joint fusion and a minimum of 1 year of follow-up was performed. Perioperative measures and ODI scores were compared using the Fisher’s exact test and two nonparametric tests, ie, the Mann–Whitney U test and the Wilcoxon signed-rank test. The results are presented as percent or median with range, as appropriate. Results Forty-nine patients from two institutions underwent sacroiliac joint fusion between 2006 and 2012. Ten patients were excluded because of incomplete data, leaving 39 evaluable patients, of whom 22 underwent open and 17 underwent MIS sacroiliac joint fusion. The MIS group was significantly older (median age 66 [39–82] years) than the open group (median age 51 [34–74] years). Surgical time and hospital stay were significantly shorter in the MIS group than in the open group. Preoperative ODI was significantly greater in the open group (median 64 [44–78]) than in the MIS group (median 53 [14–84]). Postoperative improvement in ODI was statistically significant within and between groups, with MIS resulting in greater improvement. Conclusion The open and MIS sacroiliac joint fusion techniques resulted in statistically and clinically significant improvement for patients with degenerative sacroiliitis refractory to nonoperative

  11. Clinical results of resection arthrodesis by triangular external fixation for posttraumatic arthrosis of the ankle joint in 89 cases

    PubMed Central

    2009-01-01

    The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. Patients and Methods From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Results: Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Conclusion Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations. PMID:19258207

  12. Atlantoaxial manual realignment in a patient with traumatic atlantoaxial joint disruption.

    PubMed

    Goel, Atul; Figueiredo, Antonio; Maheshwari, Shradha; Shah, Abhidha

    2010-05-01

    We report a patient with complex traumatic translatory atlantoaxial dislocation, who we treated by joint exposure and reduction of the dislocation by facet manipulation and subsequent plate and screw atlantoaxial fixation. A 28-year-old male had fallen 7.6m (25 feet), and following the fall had severe neck pain but no neurological deficit. Investigations revealed a fracture at the base of the odontoid process and posterior displacement of the entire atlas over the axis, resulting in a translatory atlantoaxial dislocation. Head traction failed as he developed severe vertigo following its application. The patient was operated upon in a prone position. We opened the atlantoaxial joint and realigned the facets using distraction and manipulation techniques and secured the joint using a plate and screw interarticular method. The patient tolerated the treatment well and was symptom-free after 28 months. Postoperative images showed good craniovertebral alignment. Although technically challenging, direct manipulation of the facets of the atlas and axis can result in excellent craniovertebral realignment.

  13. Characteristics of solder joints under fatigue loads using piezomechanical actuation

    NASA Astrophysics Data System (ADS)

    Shim, Dong-Jin; Spearing, S. Mark

    2003-07-01

    Crack initiation and growth characteristics of solder joints under fatigue loads are investigated using piezomechanical actuation. Cracks in solder joints, which can cause failure in microelectronics components, are induced via piezoelectricity in piezo-ceramic bonded joints. Lead-zirconate-titanate ceramic plates and eutectic Sn-Pb solder bonded in a double-lap shear configuration are used in the investigation. Electric field across each piezo-ceramic plate is applied such that shear stresses/strains are induced in the solder joints. The experiments show that cracks initiate in the solder joints around defects such as voids and grow in length until they coalesce with other cracks from adjacent voids. These observations are compared with the similar thermal cycling tests from the literature to show feasibility and validity of the current method in investigating the fatigue characteristics of solder joints. In some specimens, cracks in the piezo-ceramic plates are observed, and failure in the specimens generally occurred due to piezo-ceramic plate fracture. The issues encountered in implementing this methodology such as low actuation and high processing temperatures are further discussed.

  14. [Classification and Treatment of Sacroiliac Joint Dislocation].

    PubMed

    Tan, Zhen; Huang, Zhong; Li, Liang; Meng, Wei-Kun; Liu, Lei; Zhang, Hui; Wang, Guang-Lin; Huang, Fu-Guo

    2017-09-01

    To develop a renewed classification and treatment regimen for sacroiliac joint dislocation. According to the direction of dislocation of sacroiliac joint,combined iliac,sacral fractures,and fracture morphology,sacroiliac joint dislocation was classified into 4 types. Type Ⅰ (sacroiliac anterior dislocation): main fracture fragments of posterior iliac wing dislocated in front of sacroiliac joint. Type Ⅱ (sacroiliac posterior dislocation): main fracture fragments of posterior iliac wing dislocated in posterior of sacroiliac joint. Type Ⅲ (Crescent fracturedislocation of the sacroiliac joint): upward dislocation of posterior iliac wing with oblique fracture through posterior iliac wing. Type ⅢA: a large crescent fragment and dislocation comprises no more than onethird of sacroiliac joint,which is typically inferior. Type ⅢB: intermediatesize crescent fragment and dislocation comprises between one and twothirds of joint. Type ⅢC: a small crescent fragment where dislocation comprises most,but not the entire joint. Different treatment regimens were selected for different types of fractures. Treatment for type Ⅰ sacroiliac joint dislocation: anterior iliac fossa approach pry stripping reset; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅱ sacroiliac joint dislocation: posterior sacroiliac joint posterior approach; sacroiliac joint fixed with sacroiliac screw under computer guidance. Treatment for type ⅢA and ⅢB sacroiliac joint dislocation: posterior sacroiliac joint approach; sacroiliac joint fixed with reconstruction plate. Treatment for type ⅢC sacroiliac joint dislocation: sacroiliac joint closed reduction; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅳ sacroiliac joint dislocation: posterior approach; sacroiliac joint fixed with spinal pelvic fixation. Results of 24 to 72 months patient follow-up (mean 34.5 months): 100% survival,100% wound healing,and 100

  15. Inflammation is more distinct in temporomandibular joint osteoarthritis compared to the knee joint.

    PubMed

    Vos, Lukas M; Kuijer, Roel; Huddleston Slater, James J R; Bulstra, Sjoerd K; Stegenga, Boudewijn

    2014-01-01

    Most of the current understanding of articular cartilage maintenance and degradation is derived from large load-bearing synovial joints, in particular the knee joint. The aim of this study was to identify valuable degradation markers for cartilage degradation in the temporomandibular joint (TMJ) by comparing the relative concentrations of carboxyterminal telopeptides of collagen types I and II (CTX-I and CTX-II), cartilage oligomeric matrix protein (COMP), and prostaglandin E2 (PGE2) in synovial fluid (SF) of TMJ and knee joints with cartilage degradation. In this cross-sectional comparative study, participants were recruited from the University Medical Center Groningen, The Netherlands. Patients with TMJ osteoarthritis were compared with patients with knee osteoarthritis. The outcome variables were the relative SF concentrations of CTX-I, CTX-II, COMP, and PGE2. An independent samples Mann-Whitney U test was used to compare the relative concentrations. Thirty consecutive patients (9 male, 21 female; mean age, 40.1 yr; standard deviation, 15.3 yr) with TMJ osteoarthritis and 31 consecutive patients (20 male, 11 female; mean age, 37.4 yr; standard deviation, 13.7 yr) who were scheduled for arthroscopy of the knee joint participated in this study. Significant differences were found between relative concentrations of COMP (P = .000) and PGE2 (P = .005), and no significant differences were found between relative concentrations of CTX-I (P = .720) and CTX-II (P = .242). Relative SF concentrations of COMP and PGE2 showed significant differences between the TMJ and the knee joint, suggesting that there are differences in pathophysiology and that the inflammatory component may be more distinct in the TMJ. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Play and Joint Attention of Children with Autism in the Preschool Special Education Classroom

    PubMed Central

    Kasari, Connie

    2014-01-01

    The purpose of this study was to examine play and joint attention in children with autism (n=27) as compared to children with other developmental delays (n=28) in public preschool special education classrooms. The participants were observed in their classroom environment for 2 h over 3 separate days. Results show that children with autism spent more of their time unengaged and less time engaged in symbolic play and joint attention behaviors as compared to children with other developmental delays. Additionally, teachers seldom focused directly on symbolic play and joint attention in their teaching. These findings suggest the importance of educating teachers to target play and joint attention skills in their preschool special education classes, specifically for children with autism. PMID:22350340

  17. 11 CFR 9034.8 - Joint fundraising.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Permissible participants. Presidential primary candidates who receive matching funds under this subchapter may engage in joint fundraising with other candidates, political committees or unregistered committees or organizations. (2) Use of funds. Contributions received as a result of a candidate's participation in a joint...

  18. Quantitative in vivo MRI evaluation of lumbar facet joints and intervertebral discs using axial T2 mapping.

    PubMed

    Stelzeneder, David; Messner, Alina; Vlychou, Marianna; Welsch, Goetz H; Scheurecker, Georg; Goed, Sabine; Pieber, Karin; Pflueger, Verena; Friedrich, Klaus M; Trattnig, Siegfried

    2011-11-01

    To assess the feasibility of T2 mapping of lumbar facet joints and intervertebral discs in a single imaging slab and to compare the findings with morphological grading. Sixty lumbar spine segments from 10 low back pain patients and 5 healthy volunteers were examined by axial T2 mapping and morphological MRI at 3.0 Tesla. Regions of interest were drawn on a single slice for the facet joints and the intervertebral discs (nucleus pulposus, anterior and posterior annulus fibrosus). The Weishaupt grading was used for facet joints and the Pfirrmann score was used for morphological disc grading ("normal" vs. "abnormal" discs). The inter-rater agreement was excellent for the facet joint T2 evaluation (r = 0.85), but poor for the morphological Weishaupt grading (kappa = 0.15). The preliminary results show similar facet joint T2 values in segments with normal and abnormal Pfirrmann scores. There was no difference in mean T2 values between facet joints in different Weishaupt grading groups. Facet joint T2 values showed a weak correlation with T2 values of the posterior annulus (r = 0.32) This study demonstrates the feasibility of a combined T2 mapping approach for the facet joints and intervertebral discs using a single axial slab.

  19. Dynamic Cytology and Transcriptional Regulation of Rice Lamina Joint Development1[OPEN

    PubMed Central

    2017-01-01

    Rice (Oryza sativa) leaf angle is determined by lamina joint and is an important agricultural trait determining leaf erectness and, hence, the photosynthesis efficiency and grain yield. Genetic studies reveal a complex regulatory network of lamina joint development; however, the morphological changes, cytological transitions, and underlying transcriptional programming remain to be elucidated. A systemic morphological and cytological study reveals a dynamic developmental process and suggests a common but distinct regulation of the lamina joint. Successive and sequential cell division and expansion, cell wall thickening, and programmed cell death at the adaxial or abaxial sides form the cytological basis of the lamina joint, and the increased leaf angle results from the asymmetric cell proliferation and elongation. Analysis of the gene expression profiles at four distinct developmental stages ranging from initiation to senescence showed that genes related to cell division and growth, hormone synthesis and signaling, transcription (transcription factors), and protein phosphorylation (protein kinases) exhibit distinct spatiotemporal patterns during lamina joint development. Phytohormones play crucial roles by promoting cell differentiation and growth at early stages or regulating the maturation and senescence at later stages, which is consistent with the quantitative analysis of hormones at different stages. Further comparison with the gene expression profile of leaf inclination1, a mutant with decreased auxin and increased leaf angle, indicates the coordinated effects of hormones in regulating lamina joint. These results reveal a dynamic cytology of rice lamina joint that is fine-regulated by multiple factors, providing informative clues for illustrating the regulatory mechanisms of leaf angle and plant architecture. PMID:28500269

  20. Summary and results of the joint WMD-DAC/Alameda County bioterrorism response plan exercise.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manley, Dawn Kataoka; Lipkin, Joel; West, Todd H.

    2003-11-01

    On June 12,2003, the Alameda County Public Health Department and Sandia National Laboratories/CA jointly conducted an exercise that used a Weapons of Mass Destruction-Decision Analysis Center (WMD-DAC) bioterrorism attack simulation to test the effectiveness of the county's emergency response plan. The exercise was driven by an assumed release (in the vicinity of the Berkeley Marina), and subsequent spread, of a small quantity of aerosolized, weapons-grade anthrax spores. The simulation used several key WMD-DAC capabilities, namely: (1) integration with an atmospheric dispersion model to calculate expected dose levels in the affected areas, (2) a individual-tracking capability for both infected and non-infectedmore » persons as they made decisions, sought treatment, and received prophylaxis drugs, and (3) a user interface that allows exercise participants to affect the scenario evolution and outcome. The analysis of the county's response plan included documenting and reviewing the decisions made by participants during the exercise. Twenty-six local and regional officials representing the health care system, emergency medical services and law enforcement were involved in responding to the simulated attack. The results of this joint effort include lessons learned both by the Alameda County officials regarding implementation of their bioterrorism response plan and by the Sandia representatives about conducting exercises of this type. These observations are reviewed in this report, and they form a basis for providing a better understanding of group/individual decision processes and for identifying effective communication options among decision makers.« less

  1. Using virtual reality environment to improve joint attention associated with pervasive developmental disorder.

    PubMed

    Cheng, Yufang; Huang, Ruowen

    2012-01-01

    The focus of this study is using data glove to practice Joint attention skill in virtual reality environment for people with pervasive developmental disorder (PDD). The virtual reality environment provides a safe environment for PDD people. Especially, when they made errors during practice in virtual reality environment, there is no suffering or dangerous consequences to deal with. Joint attention is a critical skill in the disorder characteristics of children with PDD. The absence of joint attention is a deficit frequently affects their social relationship in daily life. Therefore, this study designed the Joint Attention Skills Learning (JASL) systems with data glove tool to help children with PDD to practice joint attention behavior skills. The JASL specifically focus the skills of pointing, showing, sharing things and behavior interaction with other children with PDD. The system is designed in playroom-scene and presented in the first-person perspectives for users. The functions contain pointing and showing, moving virtual objects, 3D animation, text, speaking sounds, and feedback. The method was employed single subject multiple-probe design across subjects' designs, and analysis of visual inspection in this study. It took 3 months to finish the experimental section. Surprisingly, the experiment results reveal that the participants have further extension in improving the joint attention skills in their daily life after using the JASL system. The significant potential in this particular treatment of joint attention for each participant will be discussed in details in this paper. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. The relation between residual stress, interfacial structure and the joint property in the SiO2f/SiO2-Nb joints.

    PubMed

    Ma, Qiang; Li, Zhuo Ran; Yang, Lai Shan; Lin, Jing Huang; Ba, Jin; Wang, Ze Yu; Qi, Jun Lei; Feng, Ji Cai

    2017-06-23

    In order to achieve a high-quality joint between SiO 2f /SiO 2 and metals, it is necessary to address the poor wettability of SiO 2f /SiO 2 and the high residual stress in SiO 2f /SiO 2 -Nb joint. Here, we simultaneously realize good wettability and low residual stress in SiO 2f /SiO 2 -Nb joint by combined method of HF etching treatment and Finite Element Analysis (FEA). After etching treatment, the wettability of E-SiO 2f /SiO 2 was improved, and the residual stress in the joint was decreased. In order to better control the quality of joints, efforts were made to understand the relationship between surface structure of E-SiO 2f /SiO 2 and residual stress in joint using FEA. Based on the direction of FEA results, a relationship between residual stress, surface structure and joint property in the brazed joints were investigated by experiments. As well the FEA and the brazing test results both realized the high-quality joint of E-SiO 2f /SiO 2 -Nb and the shear strength of the joint reached 61.9 MPa.

  3. Cancer risk among patients with finger and hand joint and temporo-mandibular joint prostheses in Denmark.

    PubMed

    Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H

    1999-05-31

    The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.

  4. Reduced Temporal-Central EEG Alpha Coherence during Joint Attention Perception in Adolescents with Autism Spectrum Disorder

    PubMed Central

    Jaime, Mark; McMahon, Camilla M.; Davidson, Bridget C.; Newell, Lisa C.; Mundy, Peter C.; Henderson, Heather A.

    2016-01-01

    Although prior studies have demonstrated reduced resting state EEG coherence in adults with autism spectrum disorder (ASD), no studies have explored the nature of EEG coherence during joint attention. We examined the EEG coherence of the joint attention network in adolescents with and without ASD during congruent and incongruent joint attention perception and an eyes-open resting condition. Across conditions, adolescents with ASD showed reduced right hemisphere temporal–central alpha coherence compared to typically developing adolescents. Greater right temporal–central alpha coherence during joint attention was positively associated with social cognitive performance in typical development but not in ASD. These results suggest that, in addition to a resting state, EEG coherence during joint attention perception is reduced in ASD. PMID:26659813

  5. Alloplastic total temporomandibular joint replacements: do they perform like natural joints? Prospective cohort study with a historical control.

    PubMed

    Wojczyńska, A; Leiggener, C S; Bredell, M; Ettlin, D A; Erni, S; Gallo, L M; Colombo, V

    2016-10-01

    The aim of this study was to qualitatively and quantitatively describe the biomechanics of existing total alloplastic reconstructions of temporomandibular joints (TMJ). Fifteen patients with unilateral or bilateral TMJ total joint replacements and 15 healthy controls were evaluated via dynamic stereometry technology. This non-invasive method combines three-dimensional imaging of the subject's anatomy with jaw tracking. It provides an insight into the patient's jaw joint movements in real time and provides a quantitative evaluation. The patients were also evaluated clinically for jaw opening, protrusive and laterotrusive movements, pain, interference with eating, and satisfaction with the joint replacements. The qualitative assessment revealed that condyles of bilateral total joint replacements displayed similar basic motion patterns to those of unilateral prostheses. Quantitatively, mandibular movements of artificial joints during opening, protrusion, and laterotrusion were all significantly shorter than those of controls. A significantly restricted mandibular range of motion in replaced joints was also observed clinically. Fifty-three percent of patients suffered from chronic pain at rest and 67% reported reduced chewing function. Nonetheless, patients declared a high level of satisfaction with the replacement. This study shows that in order to gain a comprehensive understanding of complex therapeutic measures, a multidisciplinary approach is needed. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Elasto-Plastic Analysis of Tee Joints Using HOT-SMAC

    NASA Technical Reports Server (NTRS)

    Arnold, Steve M. (Technical Monitor); Bednarcyk, Brett A.; Yarrington, Phillip W.

    2004-01-01

    The Higher Order Theory - Structural/Micro Analysis Code (HOT-SMAC) software package is applied to analyze the linearly elastic and elasto-plastic response of adhesively bonded tee joints. Joints of this type are finding an increasing number of applications with the increased use of composite materials within advanced aerospace vehicles, and improved tools for the design and analysis of these joints are needed. The linearly elastic results of the code are validated vs. finite element analysis results from the literature under different loading and boundary conditions, and new results are generated to investigate the inelastic behavior of the tee joint. The comparison with the finite element results indicates that HOT-SMAC is an efficient and accurate alternative to the finite element method and has a great deal of potential as an analysis tool for a wide range of bonded joints.

  7. Robust Joint Graph Sparse Coding for Unsupervised Spectral Feature Selection.

    PubMed

    Zhu, Xiaofeng; Li, Xuelong; Zhang, Shichao; Ju, Chunhua; Wu, Xindong

    2017-06-01

    In this paper, we propose a new unsupervised spectral feature selection model by embedding a graph regularizer into the framework of joint sparse regression for preserving the local structures of data. To do this, we first extract the bases of training data by previous dictionary learning methods and, then, map original data into the basis space to generate their new representations, by proposing a novel joint graph sparse coding (JGSC) model. In JGSC, we first formulate its objective function by simultaneously taking subspace learning and joint sparse regression into account, then, design a new optimization solution to solve the resulting objective function, and further prove the convergence of the proposed solution. Furthermore, we extend JGSC to a robust JGSC (RJGSC) via replacing the least square loss function with a robust loss function, for achieving the same goals and also avoiding the impact of outliers. Finally, experimental results on real data sets showed that both JGSC and RJGSC outperformed the state-of-the-art algorithms in terms of k -nearest neighbor classification performance.

  8. Longitudinal joint treatment, interim report - third year, March 2004.

    DOT National Transportation Integrated Search

    2004-03-01

    Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...

  9. Longitudinal joint treatment, interim report - fourth year, March 2005.

    DOT National Transportation Integrated Search

    2005-03-01

    Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...

  10. Quantification of joint inflammation in rheumatoid arthritis by time-resolved diffuse optical spectroscopy and tracer kinetic modeling

    NASA Astrophysics Data System (ADS)

    Ioussoufovitch, Seva; Morrison, Laura B.; Lee, Ting-Yim; St. Lawrence, Keith; Diop, Mamadou

    2015-03-01

    Rheumatoid arthritis (RA) is characterized by chronic synovial inflammation, which can cause progressive joint damage and disability. Diffuse optical spectroscopy (DOS) and imaging have the potential to become potent monitoring tools for RA. We devised a method that combined time-resolved DOS and tracer kinetics modeling to rapidly and reliably quantify blood flow in the joint. Preliminary results obtained from two animals show that the technique can detect joint inflammation as early as 5 days after onset.

  11. A microstructurally based model of solder joints under conditions of thermomechanical fatigue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frear, D.R.; Burchett, S.N.; Rashid, M.M.

    The thermomechanical fatigue failure of solder joints in increasingly becoming an important reliability issue. In this paper we present two computational methodologies that have been developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions that are based on metallurgical tests as fundamental input for constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations from this model agree well with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. Themore » single phase model is a computational technique that was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests and the results showed an adequate fit to experimental results. The single-phase model could be very useful for conditions where microstructural evolution is not a dominant factor in fatigue.« less

  12. An in vitro simulation method for the tribological assessment of complete natural hip joints

    PubMed Central

    Fisher, John; Williams, Sophie

    2017-01-01

    The use of hip joint simulators to evaluate the tribological performance of total hip replacements is widely reported in the literature, however, in vitro simulation studies investigating the tribology of the natural hip joint are limited with heterogeneous methodologies reported. An in vitro simulation system for the complete natural hip joint, enabling the acetabulum and femoral head to be positioned with different orientations whilst maintaining the correct joint centre of rotation, was successfully developed for this study. The efficacy of the simulation system was assessed by testing complete, matched natural porcine hip joints and porcine hip hemiarthroplasty joints in a pendulum friction simulator. The results showed evidence of biphasic lubrication, with a non-linear increase in friction being observed in both groups. Lower overall mean friction factor values in the complete natural joint group that increased at a lower rate over time, suggest that the exudation of fluid and transition to solid phase lubrication occurred more slowly in the complete natural hip joint compared to the hip hemiarthroplasty joint. It is envisaged that this methodology will be used to investigate morphological risk factors for developing hip osteoarthritis, as well as the effectiveness of early interventional treatments for degenerative hip disease. PMID:28886084

  13. Experimental and numerical study of Bondura® 6.6 PIN joints

    NASA Astrophysics Data System (ADS)

    Berkani, I.; Karlsen, Ø.; Lemu, H. G.

    2017-12-01

    Pin joints are widely used in heavy-duty machinery such as aircrafts, cranes and offshore drilling equipment to transfer multi-dimensional shear forces. Their strength and service life depend on the clamping force in the contact region that is provided by interference fits. Though the interference fits provide full contact at the pin-hole interface under pretension loads, the contact interface reduces when the pin is subjected to an external load and hence a smaller contact surface leads to dramatic increase of the contact stress. The PIN joint of Bondura® Technology, investigated in this study, is an innovative solution intended to reduce the slack at the contact surface of the pin joint of heavy-duty machinery by using tapered sleeves on each end of the PIN. The study is aimed to better understand the contact pressure build-up and stress distribution in the supporting contact surface under pre-loading of the joint and the influence of temperature difference between part assembly and operation conditions. Numerical simulation using finite element method and diverse experimental tests were conducted. The numerical simulation and the test results, particularly the tests conducted with lubricated joints, show good conformance.

  14. Structural analysis of Aircraft fuselage splice joint

    NASA Astrophysics Data System (ADS)

    Udaya Prakash, R.; Kumar, G. Raj; Vijayanandh, R.; Senthil Kumar, M.; Ramganesh, T.

    2016-09-01

    In Aviation sector, composite materials and its application to each component are one of the prime factors of consideration due to the high strength to weight ratio, design flexibility and non-corrosive so that the composite materials are widely used in the low weight constructions and also it can be treated as a suitable alternative to metals. The objective of this paper is to estimate and compare the suitability of a composite skin joint in an aircraft fuselage with different joints by simulating the displacement, normal stress, vonmises stress and shear stress with the help of numerical solution methods. The reference Z-stringer component of this paper is modeled by CATIA and numerical simulation is carried out by ANSYS has been used for splice joint presents in the aircraft fuselage with three combinations of joints such as riveted joint, bonded joint and hybrid joint. Nowadays the stringers are using to avoid buckling of fuselage skin, it has joined together by rivets and they are connected end to end by splice joint. Design and static analysis of three-dimensional models of joints such as bonded, riveted and hybrid are carried out and results are compared.

  15. Multi-joint postural behavior in patients with knee osteoarthritis.

    PubMed

    Turcot, Katia; Sagawa, Yoshimasa; Hoffmeyer, Pierre; Suvà, Domizio; Armand, Stéphane

    2015-12-01

    Previous studies have demonstrated balance impairment in patients with knee osteoarthritis (OA). Although it is currently accepted that postural control depends on multi-joint coordination, no study has previously considered this postural strategy in patients suffering from knee OA. The objectives of this study were to investigate the multi-joint postural behavior in patients with knee OA and to evaluate the association with clinical outcomes. Eighty-seven patients with knee OA and twenty-five healthy elderly were recruited to the study. A motion analysis system and two force plates were used to investigate the joint kinematics (trunk and lower body segments), the lower body joint moments, the vertical ground reaction force ratio and the center of pressure (COP) during a quiet standing task. Pain, functional capacity and quality of life status were also recorded. Patients with symptomatic and severe knee OA adopt a more flexed posture at all joint levels in comparison with the control group. A significant difference in the mean ratio was found between groups, showing an asymmetric weight distribution in patients with knee OA. A significant decrease in the COP range in the anterior-posterior direction was also observed in the group of patients. Only small associations were observed between postural impairments and clinical outcomes. This study brings new insights regarding the postural behavior of patients with severe knee OA during a quiet standing task. The results confirm the multi-joint asymmetric posture adopted by this population. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Passive Joint Forces Are Tuned to Limb Use in Insects and Drive Movements without Motor Activity

    PubMed Central

    Ache, Jan M.; Matheson, Thomas

    2013-01-01

    Summary Background Limb movements are generally driven by active muscular contractions working with and against passive forces arising in muscles and other structures. In relatively heavy limbs, the effects of gravity and inertia predominate, whereas in lighter limbs, passive forces intrinsic to the limb are of greater consequence. The roles of passive forces generated by muscles and tendons are well understood, but there has been little recognition that forces originating within joints themselves may also be important, and less still that these joint forces may be adapted through evolution to complement active muscle forces acting at the same joint. Results We examined the roles of passive joint forces in insect legs with different arrangements of antagonist muscles. We first show that passive forces modify actively generated movements of a joint across its working range, and that they can be sufficiently strong to generate completely passive movements that are faster than active movements observed in natural behaviors. We further demonstrate that some of these forces originate within the joint itself. In legs of different species adapted to different uses (walking, jumping), these passive joint forces complement the balance of strength of the antagonist muscles acting on the joint. We show that passive joint forces are stronger where they assist the weaker of two antagonist muscles. Conclusions In limbs where the dictates of a key behavior produce asymmetry in muscle forces, passive joint forces can be coadapted to provide the balance needed for the effective generation of other behaviors. PMID:23871240

  17. Dubious space for Artelon joint resurfacing for basal thumb (trapeziometacarpal joint) osteoarthritis. A systematic review.

    PubMed

    Smeraglia, Francesco; Mariconda, Massimo; Balato, Giovanni; Di Donato, Sigismondo Luca; Criscuolo, Giovanni; Maffulli, Nicola

    2018-06-01

    Trapeziometacarpal arthritis is a common and disabling condition. There is no evidence in the literature of superiority of one surgical procedure over others. Several prosthetic implants have been introduced to preserve joint mobility. We searched the on Medline (PubMed), Web of Science and Scopus databases using the combined keywords 'artelon', 'thumb', 'carpometacarpal', 'trapeziometacarpal' and 'rhizoarthrosis'; 11 studies were identified. The use of Artelon implant is not recommended because of its high revision rate and worse outcomes compared to conventional techniques. Inert materials subjected to compressive and shearing forces could produce debris and subsequent inflammatory response. There is debate in the published scientific literature regarding the role of preoperative antibiotic profilaxis and post-surgery inflammatory response. Standard techniques such as trapeziectomy alone or combined with interposition or suspensionplasty offer effective treatment for thumb basal joint arthritis. Several prosthetic implants show promising results in terms of pain relief and functional request, but there is a need of long-term randomized controlled trials to demonstrate their equivalence, and eventually superiority, compared to standard techniques.

  18. Spacesuit mobility knee joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1979-01-01

    Pressure suit mobility joints are for use in interconnecting adjacent segments of an hermetically sealed spacesuit in which low torques, low leakage and a high degree of reliability are required. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics and includes linkages which restrain the joint from longitudinal distension and includes a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  19. Robotic joint experiments under ultravacuum

    NASA Technical Reports Server (NTRS)

    Borrien, A.; Petitjean, L.

    1988-01-01

    First, various aspects of a robotic joint development program, including gearbox technology, electromechanical components, lubrication, and test results, are discussed. Secondly, a test prototype of the joint allowing simulation of robotic arm dynamic effects is presented. This prototype is tested under vacuum with different types of motors and sensors to characterize the functional parameters: angular position error, mechanical backlash, gearbox efficiency, and lifetime.

  20. Joint angle sensors for closed-loop control

    NASA Astrophysics Data System (ADS)

    Ko, Wen H.; Miao, Chih-Lei

    In order to substitute braces that have built-in goniometers and to provide feedback signals for closed loop control of lower extremity Functional Neuromuscular System in paraplegics, a stretchable capacitive sensor was developed to accurately detect angular movement in joints. Promising clinical evaluations on the knee joints of a paraplegic and a volunteer were done. The evaluations show great promise for the possibility of implantation applications.

  1. Magnetic resonance-guided focused ultrasound treatment of facet joint pain: summary of preclinical phase

    PubMed Central

    2014-01-01

    Study design A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted to test the feasibility, safety, and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for treating facet joint pain. Objective The goal of the current study was to develop a novel method for accurate and safe noninvasive facet joint ablation using MRgFUS. Summary of background data Facet joints are a common source of chronic back pain. Direct facet joint interventions include medial branch nerve ablation and intra-articular injections, which are widely used, but limited in the short and long term. MRgFUS is a breakthrough technology that enables accurate delivery of high-intensity focused ultrasound energy to create a localized temperature rise for tissue ablation, using MR guidance for treatment planning and real-time feedback. Methods We validated the feasibility, safety, and efficacy of MRgFUS for facet joint ablation using the ExAblate 2000® System (InSightec Ltd., Tirat Carmel, Israel) and confirmed the system's ability to ablate the edge of the facet joint and all terminal nerves innervating the joint. A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted. Results The experiments showed that targeting the facet joint with energies of 150–450 J provides controlled and accurate heating at the facet joint edge without penetration to the vertebral body, spinal canal, or root foramina. Treating with reduced diameter of the acoustic beam is recommended since a narrower beam improves access to the targeted areas. Conclusions MRgFUS can safely and effectively target and ablate the facet joint. These results are highly significant, given that this is the first study to demonstrate the potential of MRgFUS to treat facet joint pain. PMID:24921048

  2. The John Charnley Award Paper. The role of joint fluid in the tribology of total joint arthroplasty.

    PubMed

    Mazzucco, Daniel; Spector, Myron

    2004-12-01

    The effect of joint fluid on the tribology (ie, lubrication, friction, and wear) of total hip arthroplasty has not yet been investigated adequately. In the current study, a friction assay was used to assess four hypotheses relating to the effect of human joint fluid and its principal components on the articulation of metal-on-polyethylene. First, joint fluid was found to produce a widely varying amount of friction between cobalt-chromium and polyethylene; this range exceeded the range produced when the articulation was lubricated by water or bovine serum. Second, it was shown that hyaluronic acid, phospholipid, albumin, and gamma-globulin were not acting as boundary lubricants, but that one or more other proteins (as yet unidentified) were responsible for reducing friction in this couple. Third, lower friction was found when oxidized zirconium alloy replaced cobalt-chromium as a bearing surface on polyethylene. Finally, a pilot study suggested that lubricin, which contributes to cartilage-on-cartilage lubrication, is not a protein responsible for the tribological variabiation found among joint fluid samples. The current study showed that joint fluid is a patient factor that influences the tribology of metal-on-polyethylene arthroplasty.

  3. Joint inversion of fundamental and higher mode Rayleigh waves

    USGS Publications Warehouse

    Luo, Y.-H.; Xia, J.-H.; Liu, J.-P.; Liu, Q.-S.

    2008-01-01

    In this paper, we analyze the characteristics of the phase velocity of fundamental and higher mode Rayleigh waves in a six-layer earth model. The results show that fundamental mode is more sensitive to the shear velocities of shallow layers (< 7 m) and concentrated in a very narrow band (around 18 Hz) while higher modes are more sensitive to the parameters of relatively deeper layers and distributed over a wider frequency band. These properties provide a foundation of using a multi-mode joint inversion to define S-wave velocity. Inversion results of both synthetic data and a real-world example demonstrate that joint inversion with the damped least squares method and the SVD (Singular Value Decomposition) technique to invert Rayleigh waves of fundamental and higher modes can effectively reduce the ambiguity and improve the accuracy of inverted S-wave velocities.

  4. Tribological performance of the biological components of synovial fluid in artificial joint implants

    NASA Astrophysics Data System (ADS)

    Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Moradi, Ali; Masjuki, H. H.; Pingguan-Murphy, Belinda

    2015-08-01

    The concentration of biological components of synovial fluid (such as albumin, globulin, hyaluronic acid, and lubricin) varies between healthy persons and osteoarthritis (OA) patients. The aim of the present study is to compare the effects of such variation on tribological performance in a simulated hip joint model. The study was carried out experimentally by utilizing a pin-on-disk simulator on ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) hip joint implants. The experimental results show that both friction and wear of artificial joints fluctuate with the concentration level of biological components. Moreover, the performance also varies between material combinations. Wear debris sizes and shapes produced by ceramic and polyethylene were diverse. We conclude that the biological components of synovial fluid and their concentrations should be considered in order to select an artificial hip joint to best suit that patient.

  5. Repair of massively defected hemi-joints using demineralized osteoarticular allografts with protected cartilage.

    PubMed

    Li, Siming; Yang, Xiaohong; Tang, Shenghui; Zhang, Xunmeng; Feng, Zhencheng; Cui, Shuliang

    2015-08-01

    Surgical replacement of massively defected joints necessarily relies on osteochondral grafts effective to both of bone and cartilage. Demineralized bone matrix (DBM) retains the osteoconductivity but destroys viable chondrocytes in the cartilage portion essential for successful restoration of defected joints. This study prepared osteochondral grafts of DBM with protected cartilage. Protected cartilage portions was characterized by cellular and molecular biology and the grafts were allogenically used for grafting. Protected cartilage showed similar histomorphological structure and protected proteins estimated by total proteins and cartilage specific proteins as in those of fresh controls when DBMs were generated in bone portions. Such grafts were successfully used for simultaneously repair of bone and cartilage in massively defected osteoarticular joints within 16 weeks post-surgery. These results present an allograft with clinical potential for simultaneous restoration of bone and cartilage in defected joints.

  6. Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint.

    PubMed

    McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A

    2012-08-30

    Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.

  7. The Effect of Preoperative Antimicrobial Prophylaxis on Intraoperative Culture Results in Patients with a Suspected or Confirmed Prosthetic Joint Infection: a Systematic Review.

    PubMed

    Wouthuyzen-Bakker, Marjan; Benito, Natividad; Soriano, Alex

    2017-09-01

    Obtaining reliable cultures during revision arthroplasty is important to adequately diagnose and treat a prosthetic joint infection (PJI). The influence of antimicrobial prophylaxis on culture results remains unclear. Since withholding prophylaxis increases the risk for surgical site infections, clarification on this topic is critical. A systematic review was performed with the following research question: in patients who undergo revision surgery of a prosthetic joint, does preoperative antimicrobial prophylaxis affect the culture yield of intraoperative samples in comparison with nonpreoperative antimicrobial prophylaxis? Seven articles were included in the final analysis. In most studies, standard diagnostic culture techniques were used. In patients with a PJI, pooled analysis showed a culture yield of 88% (145/165) in the prophylaxis group versus 95% (344/362) in the nonprophylaxis group ( P = 0.004). Subanalysis of patients with chronic PJIs showed positive cultures in 88% (78/89) versus 91% (52/57), respectively ( P = 0.59). In patients with a suspected chronic infection, a maximum difference of 4% in culture yield between the prophylaxis and nonprophylaxis groups was observed. With the use of standard culture techniques, antimicrobial prophylaxis seems to affect cultures in a minority of patients. Along with the known risk of surgical site infections due to inadequate timing of antimicrobial prophylaxis, we discourage the postponement of prophylaxis until tissue samples are obtained in revision surgery. Future studies are necessary to conclude whether the small percentage of false-negative cultures after prophylaxis can be further reduced with the use of more-sensitive culture techniques, like sonication. Copyright © 2017 American Society for Microbiology.

  8. The Effect of Preoperative Antimicrobial Prophylaxis on Intraoperative Culture Results in Patients with a Suspected or Confirmed Prosthetic Joint Infection: a Systematic Review

    PubMed Central

    Benito, Natividad; Soriano, Alex

    2017-01-01

    ABSTRACT Obtaining reliable cultures during revision arthroplasty is important to adequately diagnose and treat a prosthetic joint infection (PJI). The influence of antimicrobial prophylaxis on culture results remains unclear. Since withholding prophylaxis increases the risk for surgical site infections, clarification on this topic is critical. A systematic review was performed with the following research question: in patients who undergo revision surgery of a prosthetic joint, does preoperative antimicrobial prophylaxis affect the culture yield of intraoperative samples in comparison with nonpreoperative antimicrobial prophylaxis? Seven articles were included in the final analysis. In most studies, standard diagnostic culture techniques were used. In patients with a PJI, pooled analysis showed a culture yield of 88% (145/165) in the prophylaxis group versus 95% (344/362) in the nonprophylaxis group (P = 0.004). Subanalysis of patients with chronic PJIs showed positive cultures in 88% (78/89) versus 91% (52/57), respectively (P = 0.59). In patients with a suspected chronic infection, a maximum difference of 4% in culture yield between the prophylaxis and nonprophylaxis groups was observed. With the use of standard culture techniques, antimicrobial prophylaxis seems to affect cultures in a minority of patients. Along with the known risk of surgical site infections due to inadequate timing of antimicrobial prophylaxis, we discourage the postponement of prophylaxis until tissue samples are obtained in revision surgery. Future studies are necessary to conclude whether the small percentage of false-negative cultures after prophylaxis can be further reduced with the use of more-sensitive culture techniques, like sonication. PMID:28659322

  9. Joint Enabling Capabilities Command

    Science.gov Websites

    Executive Director Chief of Staff Joint Planning Support Element Joint Communications Support Element mission Joint Enabling Capabilities Command provides decisive joint communications, planning and public and responsive support for joint communications, planning and public affairs. Priorities * Deliver

  10. Fluoroscopic Sacroiliac Joint Injection: Is Oblique Angulation Really Necessary?

    PubMed

    Khuba, Sandeep; Agarwal, Anil; Gautam, Sujeet; Kumar, Sanjay

    2016-01-01

    The conventional technique for sacroiliac (SI) joint injection involves aligning the anterior and posterior aspects of the SI joint under fluoroscopic guidance and then entering the SI joint in the most caudal aspect. We wish to highlight that there is no added advantage to aligning both the anterior and posterior joint lines of the SI joint as it is time consuming, associated with additional radiation exposure, and may make the entry into the posterior SI joint technically more difficult. Observational study. Pain Clinic, Department of Anesthesiology. With the patient lying prone on fluoroscopy table, SI joint injection is performed with a 22 G, 10 cm spinal needle in a true anteroposterior (AP) view, where anterior and posterior SI joint spaces are seen as separate entities, where the medial joint space represents the posterior SI joint and the lateral joint space represents the anterior SI joint. The distal 1 cm of the medial joint space is entered under AP view. If the SI joint is seen as a straight line rather than 2 joint spaces in the AP view then the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint, thus facilitating entry into this part of the joint which was confirmed by administering 0.3 to 0.5 mL of radiopaque contrast medium. Sixty SI joints of 58 patients were injected under an AP fluoroscopic view. Forty-two (70%) SI joints were seen as 2 separate medial and lateral joint spaces and were entered in distal 1 cm of the medial joint space. In 18 (30%) joints seen as a straight line rather than 2 separate spaces, the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint and then the SI joint was entered in its distal 1 cm. Confirmation of entry into the SI joint was confirmed by with 0.3 to 0.5 mL of radiopaque contrast medium. In 4 cases the joints did not show the correct radiopaque contrast spread (3/42 and 1

  11. Brief Report: High and Low Level Initiations of Joint Attention, and Response to Joint Attention--Differential Relationships with Language and Imitation

    ERIC Educational Resources Information Center

    Pickard, Katherine E.; Ingersoll, Brooke R.

    2015-01-01

    Frequency of high-level (showing/pointing) and low-level (coordinated gaze shifts) behaviors on the Early Social Communication Scales are often used as a measure of joint attention initiations (IJA). This study examined the degree to which these skills and response to joint attention (RJA; e.g. gaze following) were differentially related to…

  12. Experimental analysis of mechanical joints strength by means of energy dissipation

    NASA Astrophysics Data System (ADS)

    Wolf, Alexander; Lafarge, Remi; Kühn, Tino; Brosius, Alexander

    2018-05-01

    Designing complex structures with the demand for weight reduction leads directly to a multi-material concept. This mixture has to be joined securely and welding, mechanical joining and the usage of adhesives are commonly used for that purpose. Sometimes also a mix of at least two materials is useful to combine the individual advantages. The challenge is the non-destructive testing of these connections because destructive testing requires a lot of preparation and expensive testing equipment. The authors show a testing method by measuring and analysing the energy dissipation in mechanical joints. Known methods are radiography, thermography and ultrasound testing. Unfortunately, the usage of these methods is difficult and often not usable in fibre-reinforced-plastics. The presented approach measures the propagation of the elastic strain wave through the joint. A defined impact strain is detected with by strain-gauges whereby the transmitter is located on one side of the joint and the receiver on the other, respectively. Because of different mechanisms, energy dissipates by passing the joint areas. Main reasons are damping caused by friction and material specific damping. Insufficient performed joints lead to an effect especially in the friction damping. By the measurement of the different strains and the resulting energy loss a statement to the connection quality is given. The possible defect during the execution of the joint can be identified by the energy loss and strain vs. time curve. After the description of the method, the authors present the results of energy dissipation measurements at a bolted assembly with different locking torques. By the adjustable tightening torques for the screw connections easily a variation of the contact pressure can be applied and analysed afterwards. The outlook will give a statement for the usability for other mechanical joints and fibre-reinforced-plastics.

  13. Adaptive independent joint control of manipulators - Theory and experiment

    NASA Technical Reports Server (NTRS)

    Seraji, H.

    1988-01-01

    The author presents a simple decentralized adaptive control scheme for multijoint robot manipulators based on the independent joint control concept. The proposed control scheme for each joint consists of a PID (proportional integral and differential) feedback controller and a position-velocity-acceleration feedforward controller, both with adjustable gains. The static and dynamic couplings that exist between the joint motions are compensated by the adaptive independent joint controllers while ensuring trajectory tracking. The proposed scheme is implemented on a MicroVAX II computer for motion control of the first three joints of a PUMA 560 arm. Experimental results are presented to demonstrate that trajectory tracking is achieved despite strongly coupled, highly nonlinear joint dynamics. The results confirm that the proposed decentralized adaptive control of manipulators is feasible, in spite of strong interactions between joint motions. The control scheme presented is computationally very fast and is amenable to parallel processing implementation within a distributed computing architecture, where each joint is controlled independently by a simple algorithm on a dedicated microprocessor.

  14. Common Bolted Joint Analysis Tool

    NASA Technical Reports Server (NTRS)

    Imtiaz, Kauser

    2011-01-01

    Common Bolted Joint Analysis Tool (comBAT) is an Excel/VB-based bolted joint analysis/optimization program that lays out a systematic foundation for an inexperienced or seasoned analyst to determine fastener size, material, and assembly torque for a given design. Analysts are able to perform numerous what-if scenarios within minutes to arrive at an optimal solution. The program evaluates input design parameters, performs joint assembly checks, and steps through numerous calculations to arrive at several key margins of safety for each member in a joint. It also checks for joint gapping, provides fatigue calculations, and generates joint diagrams for a visual reference. Optimum fastener size and material, as well as correct torque, can then be provided. Analysis methodology, equations, and guidelines are provided throughout the solution sequence so that this program does not become a "black box:" for the analyst. There are built-in databases that reduce the legwork required by the analyst. Each step is clearly identified and results are provided in number format, as well as color-coded spelled-out words to draw user attention. The three key features of the software are robust technical content, innovative and user friendly I/O, and a large database. The program addresses every aspect of bolted joint analysis and proves to be an instructional tool at the same time. It saves analysis time, has intelligent messaging features, and catches operator errors in real time.

  15. Joint sparse coding based spatial pyramid matching for classification of color medical image.

    PubMed

    Shi, Jun; Li, Yi; Zhu, Jie; Sun, Haojie; Cai, Yin

    2015-04-01

    Although color medical images are important in clinical practice, they are usually converted to grayscale for further processing in pattern recognition, resulting in loss of rich color information. The sparse coding based linear spatial pyramid matching (ScSPM) and its variants are popular for grayscale image classification, but cannot extract color information. In this paper, we propose a joint sparse coding based SPM (JScSPM) method for the classification of color medical images. A joint dictionary can represent both the color information in each color channel and the correlation between channels. Consequently, the joint sparse codes calculated from a joint dictionary can carry color information, and therefore this method can easily transform a feature descriptor originally designed for grayscale images to a color descriptor. A color hepatocellular carcinoma histological image dataset was used to evaluate the performance of the proposed JScSPM algorithm. Experimental results show that JScSPM provides significant improvements as compared with the majority voting based ScSPM and the original ScSPM for color medical image classification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Clinical results of resection arthrodesis by triangular external fixation for posttraumatic arthrosis of the ankle joint in 89 cases.

    PubMed

    Kiene, J; Schulz, Arndt P; Hillbricht, S; Jürgens, Ch; Paech, A

    2009-01-28

    The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations.

  17. Diminishing friction of joint surfaces as initiating factor for destabilising permafrost rocks?

    NASA Astrophysics Data System (ADS)

    Funk, Daniel; Krautblatter, Michael

    2010-05-01

    Degrading alpine permafrost due to changing climate conditions causes instabilities in steep rock slopes. Due to a lack in process understanding, the hazard is still difficult to asses in terms of its timing, location, magnitude and frequency. Current research is focused on ice within joints which is considered to be the key-factor. Monitoring of permafrost-induced rock failure comprises monitoring of temperature and moisture in rock-joints. The effect of low temperatures on the strength of intact rock and its mechanical relevance for shear strength has not been considered yet. But this effect is signifcant since compressive and tensile strength is reduced by up to 50% and more when rock thaws (Mellor, 1973). We hypotheisze, that the thawing of permafrost in rocks reduces the shear strength of joints by facilitating the shearing/damaging of asperities due to the drop of the compressive/tensile strength of rock. We think, that decreasing surface friction, a neglected factor in stability analysis, is crucial for the onset of destabilisation of permafrost rocks. A potential rock slide within the permafrost zone in the Wetterstein Mountains (Zugspitze, Germany) is the basis for the data we use for the empirical joint model of Barton (1973) to estimate the peak shear strength of the shear plane. Parameters are the JRC (joint roughness coefficient), the JCS (joint compressive strength) and the residual friction angle (φr). The surface roughness is measured in the field with a profile gauge to create 2D-profiles of joint surfaces. Samples of rock were taken to the laboratory to measure compressive strength using a high-impact Schmidt-Hammer under air-dry, saturated and frozen conditions on weathered and unweathered surfaces. Plugs where cut out of the rock and sand blasted for shear tests under frozen and unfrozen conditions. Peak shear strength of frozen and unfrozen rocks will be calculated using Barton's model. First results show a mean decrease of compressive

  18. Titanium clip ball joint: a partial ossicular reconstruction prosthesis.

    PubMed

    Beutner, Dirk; Luers, Jan Christoffer; Bornitz, Matthias; Zahnert, Thomas; Huttenbrink, Karl-Bernd

    2011-06-01

    To describe a new titanium clip prosthesis for partial ossicular reconstruction with a micro ball joint in the headplate for compensation of tympanic membrane displacements. Laboratory experiments followed by 18 consecutive patients. A micro ball joint was implemented into a headplate of titanium middle ear prosthesis. First, the new prosthesis was tested in the laboratory in temporal bone experiments. Second, the new prosthesis was clinically installed in 18 patients. Results of laser Doppler vibrometry and force measurements in the laboratory experiments, analysis of a questionnaire, and preoperative and postoperative pure tone audiometry. The frictional resistance in the joint was measured to be 12 mN that should allow for adequate mobility under physiologic conditions. The effective sound transmission of the prosthesis was demonstrated by laser Doppler vibrometry. Intraoperatively, the installation of the prosthesis was always straightforward with headplate prosthesis shaft angles between 60 and 90 degrees. Postoperatively, pure tone audiometry revealed satisfying hearing results with a remaining average air-bone gap of 18.2 dB over the frequencies 500, 1,000, 2,000, and 3,000 Hz. No signs of prosthesis dislocation were discovered within the follow-up period of approximately 6 months. The experimental data show that the new modified prosthesis headplate fulfills the requirements necessary for sound transmission. The joint allows the plate to follow movements of the tympanic membrane. This characteristic in conjunction with the proven clip design ensure for optimal prosthesis placement and effectiveness.

  19. [Development of polyaxial locking plate screw system of sacroiliac joint].

    PubMed

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P > 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than

  20. Fatigue strength of socket welded pipe joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higuchi, Makoto; Hayashi, Makoto; Yamauchi, Takayoshi

    1995-12-01

    Fully reversed four point bending fatigue tests were carried out on small diameter socket welded joints made of carbon steels. Experimental parameters were pipe diameter, thicknesses of pipe and socket wall, throat depth and shape of fillet welds, slip-on and diametral gaps in the socket welding, lack of penetration at the root of fillet welds, and peening of fillet welds. In most cases a fatigue crack started from the root of the fillet, but in the case of higher stress amplitude, it tended to start from the toe of fillet. The standard socket welded joint for a pipe with amore » 50 mm nominal diameter showed a relatively low fatigue strength of 46 MPa in stress amplitude at the 10{sup 7} cycles failure life. This value corresponds to about 1/5 of that for the smoothed base metal specimens in axial fatigue. The fatigue strength decreased with increasing pipe diameter, and increased with increasing thickness of the pipe and socket wall. The effects of throat depth and shape of fillet welds on fatigue strength were not significant. Contrary to expectation, the fatigue strength of a socket welded joint without slip-on gap is Higher than that of the joint with a normal gap. A lack of penetration at the root deleteriously reduced fatigue strength, showing 14 MPa in stress amplitude at the 10{sup 7} cycles failure life for the 50 mm diameter socket joint.« less

  1. Creep properties of Pb-free solder joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, H.G.; Morris Jr., J.W.; Hua, F.

    2002-04-01

    Describes the creep behavior of three Sn-rich solders that have become candidates for use in Pb-free solder joints: Sn-3.5Ag, Sn-3Ag-0.5Cu and Sn-0.7Cu. The three solders show the same general behavior when tested in thin joints between Cu and Ni/Au metallized pads at temperatures between 60 and 130 C. Their steady-state creep rates are separated into two regimes with different stress exponents(n). The low-stress exponents range from {approx}3-6, while the high-stress exponents are anomalously high (7-12). Strikingly, the high-stress exponent has a strong temperature dependence near room temperature, increasing significantly as the temperature drops from 95 to 60 C. The anomalousmore » creep behavior of the solders appears to be due to the dominant Sn constituent. Joints of pure Sn have stress exponents, n, that change with stress and temperature almost exactly like those of the Sn-rich solder joints. Research on creep in bulk samples of pure Sn suggests that the anomalous temperature dependence of the stress exponent may show a change in the dominant mechanism of creep. Whatever its source, it has the consequence that conventional constitutive relations for steady-state creep must be used with caution in treating Sn-rich solder joints, and qualification tests that are intended to verify performance should be carefully designed.« less

  2. Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations.

    PubMed

    Koelewijn, Anne D; van den Bogert, Antonie J

    2016-09-01

    Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Corrosion behavior in high-temperature pressurized water of Zircaloy-4 joints brazed with Zr-Cu-based amorphous filler alloys

    NASA Astrophysics Data System (ADS)

    Lee, Jung Gu; Lee, Gyoung-Ja; Park, Jin-Ju; Lee, Min-Ku

    2017-05-01

    The compositional effects of ternary Zr-Cu-X (X: Al, Fe) amorphous filler alloys on galvanic corrosion susceptibility in high-temperature pressurized water were investigated for Zircaloy-4 brazed joints. Through an Al-induced microgalvanic reaction that deteriorated the overall nobility of the joint, application of the Zr-Cu-Al filler alloy caused galvanic coupling to develop readily between the Al-bearing joint and the Al-free base metal, finally leading to massive localized corrosion of the joint. Contrastingly, joints prepared with a Zr-Cu-Fe filler alloy showed excellent corrosion resistance comparable to that of the Zircaloy-4 base metal, since the Cu and Fe elements forming fine intermetallic particles with Zr did not influence the electrochemical stability of the resultant joints. The present results demonstrate that Fe is a more suitable alloying element than Al for brazing filler alloys subjected to high-temperature corrosive environments.

  4. Computer-aided classification of optical images for diagnosis of osteoarthritis in the finger joints.

    PubMed

    Zhang, Jiang; Wang, James Z; Yuan, Zhen; Sobel, Eric S; Jiang, Huabei

    2011-01-01

    This study presents a computer-aided classification method to distinguish osteoarthritis finger joints from healthy ones based on the functional images captured by x-ray guided diffuse optical tomography. Three imaging features, joint space width, optical absorption, and scattering coefficients, are employed to train a Least Squares Support Vector Machine (LS-SVM) classifier for osteoarthritis classification. The 10-fold validation results show that all osteoarthritis joints are clearly identified and all healthy joints are ruled out by the LS-SVM classifier. The best sensitivity, specificity, and overall accuracy of the classification by experienced technicians based on manual calculation of optical properties and visual examination of optical images are only 85%, 93%, and 90%, respectively. Therefore, our LS-SVM based computer-aided classification is a considerably improved method for osteoarthritis diagnosis.

  5. [A new type sternoclavicular hook plate for unstable sternoclavicular joint dislocation and fracture].

    PubMed

    Zhang, Chuan-Yi; Lin, Lie; Liang, Jun-Bo; Wang, Bin; Chen, Guo-Fu; Chen, Hai-Xiao

    2016-11-25

    To evaluate the therapeutic effect of a new type sternoclavicular hook plate fixation in treating unstable sternoclavicular joint dislocation and fracture. From June 2011 to December 2013, 32 patients with sternoclavicular joint dislocation and fracture were treated with a new type sternoclavicular hook plate fixation, including 24 males and 8 females with an average age of 42 years ranging from 25 to 76 years;12 patients were anterior dislocation, 5 pations were posterior dislocation, 10 patients were internal extremity of clavicle fracture and 5 patients were sternoclavicular joint dislocation combined with fracture. The anterior fracture dislocation of the sternoclavicular joint adopted standard sternoclavicular joint hook plate, and the posterior dislocation was at the distal end of the hook of the steel plate, that is, the front part of the handle of the breast was added with a nut and a gasket to prevent the re-dislocation after operation. The results were evaluated according to Rockwood score. No complication happened in all patients. X-ray and CT showed that the dislocation and fracture of the sternoclavicular joint was well reduced and the plate was on right position. All patients were followed up for 6 to 24 months with an average of 10 months. At 6 to 3 months after operation, the fracture was healing without re-dislocation of the sternoclavicular joint, the medial end of the clavicle anatomical structure were restored, functional satisfaction, in which 9 patients with the swelling around sternoclavicular joint, but no pain and other symptoms. The total Rockwood score was 12.78±1.43; the results were excellent in 24 cases, good in 8 cases. The use of the new type of locking hook plate for the treatment of unstable fracture of the sternoclavicular joint, internal fixation is reliable, high security, easy to operate, to provide a reliable method for the treatment of such trauma.

  6. Evaluation of Serum Cytokines in Cats with and without Degenerative Joint Disease and Associated Pain

    PubMed Central

    Gruen, Margaret E.; Messenger, Kristen M.; Thomson, Andrea E.; Griffith, Emily H.; Aldrich, Lauren A.; Vaden, Shelly; Lascelles, BDX

    2017-01-01

    Degenerative joint disease is common in cats, with signs of pain frequently found on orthopedic examination and radiographs often showing evidence of disease. However, understanding of the pathophysiology of degenerative joint disease and associated pain remains limited. Several cytokines have been identified as having a role in pain in humans, but this has not been investigated in cats. The present study was performed to use a multiplex platform to evaluate the concentration of 19 cytokines and chemokines in serum samples obtained from cats with and without degenerative joint disease and associated pain. Samples from a total of 186 cats were analyzed, with cats representing a range of severity on radiographic and orthopedic evaluations and categorized by degenerative joint disease scores and pain scores. Results showed that cats with higher radiographic degenerative joint disease scores have higher serum concentrations of IL-4 and IL-8, while cats with higher orthopedic exam pain scores have higher concentrations of IL-8, IL-2, and TNF-α increased concentration of IL-8 in degenerative joint disease and pain may be confounded by the association with age. Discriminant analysis was unable to identify one or more cytokines that distinguish between groups of cats classified based on degenerative joint disease score category or pain score category. Finally, cluster analysis driven by analyte concentrations show separation of groups of cats, but features defining the groups remain unknown. Further studies are warranted to investigate any changes in cytokine concentrations in response to analgesic therapies, and further evaluate the elevations in cytokine concentrations found here, particularly focused on studies of local cytokines present in synovial fluid. PMID:28063477

  7. Mechanical Properties and Microstructure of TIG and FSW Joints of a New Al-Mg-Mn-Sc-Zr Alloy

    NASA Astrophysics Data System (ADS)

    Xu, Guofu; Qian, Jian; Xiao, Dan; Deng, Ying; Lu, Liying; Yin, Zhimin

    2016-04-01

    A new Al-5.8%Mg-0.4%Mn-0.25%Sc-0.10%Zr (wt.%) alloy was successfully welded by tungsten inert gas (TIG) and friction stir welding (FSW) techniques, respectively. The mechanical properties and microstructure of the welded joints were investigated by microhardness measurements, tensile tests, and microscopy methods. The results show that the ultimate tensile strength, yield strength, and elongation to failure are 358, 234 MPa, and 27.6% for TIG welded joint, and 376, 245 MPa and 31.9% for FSW joint, respectively, showing high strength and superior ductility. The TIG welded joint fails in the heat-affected zone and the fracture of FSW joint is located in stirred zone. Al-Mg-Mn-Sc-Zr alloy is characterized by lots of dislocation tangles and secondary coherent Al3(Sc,Zr) particles. The superior mechanical properties of the TIG and FSW joints are mainly derived from the Orowan strengthening and grain boundary strengthening caused by secondary coherent Al3(Sc,Zr) nano-particles (20-40 nm). For new Al-Mg-Mn-Sc-Zr alloy, the positive effect from secondary Al3(Sc, Zr) particles in the base metal can be better preserved in FSW joint than in TIG welded joint.

  8. NASA Boeing 737 Aircraft Test Results from 1996 Joint Winter Runway Friction Measurement Program

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.

    1996-01-01

    A description of the joint test program objectives and scope is given together with the performance capability of the NASA Langley B-737 instrumented aircraft. The B-737 test run matrix conducted during the first 8 months of this 5-year program is discussed with a description of the different runway conditions evaluated. Some preliminary test results are discussed concerning the Electronic Recording Decelerometer (ERD) readings and a comparison of B-737 aircraft braking performance for different winter runway conditions. Detailed aircraft parameter time history records, analysis of ground vehicle friction measurements and harmonization with aircraft braking performance, assessment of induced aircraft contaminant drag, and evaluation of the effects of other factors on aircraft/ground vehicle friction performance will be documented in a NASA Technical Report which is being prepared for publication next year.

  9. Model test study on propagation law of plane stress wave in jointed rock mass under different in-situ stresses

    NASA Astrophysics Data System (ADS)

    Dong, Qian

    2017-12-01

    The study of propagation law of plane stress wave in jointed rock mass under in-situ stress has important significance for safety excavation of underground rock mass engineering. A model test of the blasting stress waves propagating in the intact rock and jointed rock mass under different in-situ stresses was carried out, and the influencing factors on the propagation law, such as the scale of static loads and the number of joints were studied respectively. The results show that the transmission coefficient of intact rock is larger than that of jointed rock mass under the same loading condition. With the increase of confining pressure, the transmission coefficients of intact rock and jointed rock mass both show an trend of increasing first and then decreasing, and the variation of transmission coefficients in intact rock is smaller than that of jointed rock mass. Transmission coefficient of jointed rock mass decreases with the increase of the number of joints under the same loading condition, when the confining pressure is relatively small, the reduction of transmission coefficients decreases with the increasing of the number of joints, and the variation law of the reduction of transmission coefficients is contrary when the confining pressure is large.

  10. Single and Multiple Object Tracking Using a Multi-Feature Joint Sparse Representation.

    PubMed

    Hu, Weiming; Li, Wei; Zhang, Xiaoqin; Maybank, Stephen

    2015-04-01

    In this paper, we propose a tracking algorithm based on a multi-feature joint sparse representation. The templates for the sparse representation can include pixel values, textures, and edges. In the multi-feature joint optimization, noise or occlusion is dealt with using a set of trivial templates. A sparse weight constraint is introduced to dynamically select the relevant templates from the full set of templates. A variance ratio measure is adopted to adaptively adjust the weights of different features. The multi-feature template set is updated adaptively. We further propose an algorithm for tracking multi-objects with occlusion handling based on the multi-feature joint sparse reconstruction. The observation model based on sparse reconstruction automatically focuses on the visible parts of an occluded object by using the information in the trivial templates. The multi-object tracking is simplified into a joint Bayesian inference. The experimental results show the superiority of our algorithm over several state-of-the-art tracking algorithms.

  11. MP Joint Arthritis

    MedlinePlus

    ... is extensive and severe, joint replacement or joint fusion are effective surgical options. Learn more about joint ... the tabs at the top (Video, Articles/WEB, Images, JHS, Products/Vendors), or the filters on the ...

  12. Microstructural Characteristics and Mechanical Properties of an Electron Beam-Welded Ti/Cu/Ni Joint

    NASA Astrophysics Data System (ADS)

    Zhang, Feng; Wang, Ting; Jiang, Siyuan; Zhang, Binggang; Feng, Jicai

    2018-04-01

    Electron beam welding experiments of TA15 titanium alloy to GH600 nickel superalloy with and without a copper sheet interlayer were carried out. Surface appearance, microstructure and phase constitution of the joint were examined by optical microscopy, scanning electron microscopy and x-ray diffraction analysis. Mechanical properties of Ti/Ni and Ti/Cu/Ni joint were evaluated based on tensile strength and microhardness tests. The results showed that cracking occurred in Ti/Ni electron beam weldment for the formation of brittle Ni-Ti intermetallics, while a crack-free electron beam-welded Ti/Ni joint can be obtained by using a copper sheet as filler metal. The addition of copper into the weld affected the welding metallurgical process of the electron beam-welded Ti/Ni joint significantly and was helpful for restraining the formation of Ti-Ni intermetallics in Ti/Ni joint. The microstructure of the weld was mainly characterized by a copper-based solid solution and Ti-Cu interfacial intermetallic compounds. Ti-Ni intermetallic compounds were almost entirely suppressed. The hardness of the weld zone was significantly lower than that of Ti/Ni joint, and the tensile strength of the joint can be up to 282 MPa.

  13. Microstructural Characteristics and Mechanical Properties of an Electron Beam-Welded Ti/Cu/Ni Joint

    NASA Astrophysics Data System (ADS)

    Zhang, Feng; Wang, Ting; Jiang, Siyuan; Zhang, Binggang; Feng, Jicai

    2018-05-01

    Electron beam welding experiments of TA15 titanium alloy to GH600 nickel superalloy with and without a copper sheet interlayer were carried out. Surface appearance, microstructure and phase constitution of the joint were examined by optical microscopy, scanning electron microscopy and x-ray diffraction analysis. Mechanical properties of Ti/Ni and Ti/Cu/Ni joint were evaluated based on tensile strength and microhardness tests. The results showed that cracking occurred in Ti/Ni electron beam weldment for the formation of brittle Ni-Ti intermetallics, while a crack-free electron beam-welded Ti/Ni joint can be obtained by using a copper sheet as filler metal. The addition of copper into the weld affected the welding metallurgical process of the electron beam-welded Ti/Ni joint significantly and was helpful for restraining the formation of Ti-Ni intermetallics in Ti/Ni joint. The microstructure of the weld was mainly characterized by a copper-based solid solution and Ti-Cu interfacial intermetallic compounds. Ti-Ni intermetallic compounds were almost entirely suppressed. The hardness of the weld zone was significantly lower than that of Ti/Ni joint, and the tensile strength of the joint can be up to 282 MPa.

  14. RSRM Nozzle-to-Case Joint J-leg Development

    NASA Technical Reports Server (NTRS)

    Albrechtsen, Kevin U.; Eddy, Norman F.; Ewing, Mark E.; McGuire, John R.

    2003-01-01

    Since the beginning of the Space Shuttle Reusable Solid Rocket Motor (RSRM) program, nozzle-to-case joint polysulfide adhesive gas paths have occurred on several flight motors. These gas paths have allowed hot motor gases to reach the wiper O-ring. Even though these motors continue to fly safely with this condition, a desire was to reduce such occurrences. The RSRM currently uses a J-leg joint configuration on case field joints and igniter inner and outer joints. The J-leg joint configuration has been successfully demonstrated on numerous RSRM flight and static test motors, eliminating hot gas intrusion to the critical O-ring seals on these joints. Using the proven technology demonstrated on the case field joints and igniter joints, a nozzle-to-case joint J-leg design was developed for implementation on RSRM flight motors. This configuration provides an interference fit with nozzle fixed housing phenolics at assembly, with a series of pressurization gaps incorporated outboard of the joint mating surface to aid in joint pressurization and to eliminate any circumferential flow in this region. The joint insulation is bonded to the nozzle phenolics using the same pressure sensitive adhesive used in the case field joints and igniter joints. An enhancement to the nozzle-to-case joint J-leg configuration is the implementation of a carbon rope thermal barrier. The thermal barrier is located downstream of the joint bondline and is positioned within the joint in a manner where any hot gas intrusion into the joint passes through the thermal barrier, reducing gas temperatures to a level that would not affect O-rings downstream of the thermal barrier. This paper discusses the processes used in reaching a final nozzle-to-case joint J-leg design, provides structural and thermal results in support of the design, and identifies fabrication techniques and demonstrations used in arriving at the final configuration.

  15. How weak values emerge in joint measurements on cloned quantum systems.

    PubMed

    Hofmann, Holger F

    2012-07-13

    A statistical analysis of optimal universal cloning shows that it is possible to identify an ideal (but nonpositive) copying process that faithfully maps all properties of the original Hilbert space onto two separate quantum systems, resulting in perfect correlations for all observables. The joint probabilities for noncommuting measurements on separate clones then correspond to the real parts of the complex joint probabilities observed in weak measurements on a single system, where the measurements on the two clones replace the corresponding sequence of weak measurement and postselection. The imaginary parts of weak measurement statics can be obtained by replacing the cloning process with a partial swap operation. A controlled-swap operation combines both processes, making the complete weak measurement statistics accessible as a well-defined contribution to the joint probabilities of fully resolved projective measurements on the two output systems.

  16. Brief Report: Reduced Temporal-Central EEG Alpha Coherence During Joint Attention Perception in Adolescents with Autism Spectrum Disorder.

    PubMed

    Jaime, Mark; McMahon, Camilla M; Davidson, Bridget C; Newell, Lisa C; Mundy, Peter C; Henderson, Heather A

    2016-04-01

    Although prior studies have demonstrated reduced resting state EEG coherence in adults with autism spectrum disorder (ASD), no studies have explored the nature of EEG coherence during joint attention. We examined the EEG coherence of the joint attention network in adolescents with and without ASD during congruent and incongruent joint attention perception and an eyes-open resting condition. Across conditions, adolescents with ASD showed reduced right hemisphere temporal-central alpha coherence compared to typically developing adolescents. Greater right temporal-central alpha coherence during joint attention was positively associated with social cognitive performance in typical development but not in ASD. These results suggest that, in addition to a resting state, EEG coherence during joint attention perception is reduced in ASD.

  17. Phalangeal joints kinematics during ostrich (Struthio camelus) locomotion

    PubMed Central

    Ji, Qiaoli; Luo, Gang; Xue, Shuliang; Ma, Songsong; Li, Jianqiao

    2017-01-01

    The ostrich is a highly cursorial bipedal land animal with a permanently elevated metatarsophalangeal joint supported by only two toes. Although locomotor kinematics in walking and running ostriches have been examined, these studies have been largely limited to above the metatarsophalangeal joint. In this study, kinematic data of all major toe joints were collected from gaits with double support (slow walking) to running during stance period in a semi-natural setup with two selected cooperative ostriches. Statistical analyses were conducted to investigate the effect of locomotor gait on toe joint kinematics. The MTP3 and MTP4 joints exhibit the largest range of motion whereas the first phalangeal joint of the 4th toe shows the largest motion variability. The interphalangeal joints of the 3rd and 4th toes present very similar motion patterns over stance phases of slow walking and running. However, the motion patterns of the MTP3 and MTP4 joints and the vertical displacement of the metatarsophalangeal joint are significantly different during running and slow walking. Because of the biomechanical requirements, osctriches are likely to select the inverted pendulum gait at low speeds and the bouncing gait at high speeds to improve movement performance and energy economy. Interestingly, the motions of the MTP3 and MTP4 joints are highly synchronized from slow to fast locomotion. This strongly suggests that the 3rd and 4th toes really work as an “integrated system” with the 3rd toe as the main load bearing element whilst the 4th toe as the complementary load sharing element with a primary role to ensure the lateral stability of the permanently elevated metatarsophalangeal joint. PMID:28097064

  18. NORTH NORTHWEST, SHOWING ABUTMENTS AND PIER MADE OF CUT, SQUARED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTH NORTHWEST, SHOWING ABUTMENTS AND PIER MADE OF CUT, SQUARED STONE WITH MORTARED JOINTS. - Crum Bridge, Spanning Little Muskingum River, TR 384A (formerly Old Camp Road), Rinard Mills, Monroe County, OH

  19. Effect of Post-Weld Heat Treatment on Microstructure and Mechanical Properties of X52 Linepipe HFIW Joints

    NASA Astrophysics Data System (ADS)

    Kavousi Sisi, A.; Mirsalehi, S. E.

    2015-04-01

    In the present paper, influences of normalization heat treatment on microstructural and mechanical properties of high-frequency induction welded (HFIW) joints of X52 steel have been investigated. HFIW joints were post-weld heat treated at different times and temperatures. The microstructure and mechanical properties of the heat treated joints were then comprehensively investigated. Based on the results, a proper normalization of the primary fine grain steel caused the grain size to increase; but because of converting brittle microstructure into ductile microstructure, it caused the toughness to increase also. In addition, the ductility of the joints was enhanced. Nevertheless, tensile strength, yield strength, and hardness were reduced. The results showed that 950 °C was the optimum normalization temperature from the standpoint of fracture toughness for the X52 steel joints. At 1050 °C, the carbides and/or nitrides in the steel dissolved, and excessive grain growth occurred. Hence, the maximum allowable temperature for normalization was found to be 1000 °C.

  20. Flaw Tolerance In Lap Shear Brazed Joints. Part 2

    NASA Technical Reports Server (NTRS)

    Wang, Len; Flom, Yury

    2003-01-01

    This paper presents results of the second part of an on-going effort to gain better understanding of defect tolerance in braze joints. In the first part of this three-part series, we mechanically tested and modeled the strength of the lap joints as a function of the overlap distance. A failure criterion was established based on the zone damage theory, which predicts the dependence of the lap joint shear strength on the overlap distance, based on the critical size of a finite damage zone or an overloaded region in the joint. In this second part of the study, we experimentally verified the applicability of the damage zone criterion on prediction of the shear strength of the lap joint and introduced controlled flaws into the lap joints. The purpose of the study was to evaluate the lap joint strength as a function of flaw size and its location through mechanical testing and nonlinear finite element analysis (FEA) employing damage zone criterion for definition of failure. The results obtained from the second part of the investigation confirmed that the failure of the ductile lap shear brazed joints occurs when the damage zone reaches approximately 10% of the overlap width. The same failure criterion was applicable to the lap joints containing flaws.

  1. Ultrasonic guided wave inspection of Inconel 625 brazed lap joints

    NASA Astrophysics Data System (ADS)

    Comot, Pierre; Bocher, Philippe; Belanger, Pierre

    2016-04-01

    The aerospace industry has been investigating the use of brazing for structural joints, as a mean of reducing cost and weight. There therefore is a need for a rapid, robust, and cost-effective non-destructive testing method for evaluating the structural integrity of the joints. The mechanical strength of brazed joints depends mainly on the amount of brittle phases in their microstructure. Ultrasonic guided waves offer the possibility of detecting brittle phases in joints using spatio-temporal measurements. Moreover, they offer the opportunity to inspect complex shape joints. This study focused on the development of a technique based on ultrasonic guided waves for the inspection of Inconel 625 lap joints brazed with BNi-2 filler metal. A finite element model of a lap joint was used to optimize the inspection parameters and assess the feasibility of detecting the amount of brittle phases in the joint. A finite element parametric study simulating the input signal shape, the center frequency, and the excitation direction was performed. The simulations showed that the ultrasonic guided wave energy transmitted through, and reflected from, the joints was proportional to the amount of brittle phases in the joint.

  2. Fabrication and Testing of Durable Redundant and Fluted-Core Joints for Composite Sandwich Structures

    NASA Technical Reports Server (NTRS)

    Lin, Shih-Yung; Splinter, Scott C.; Tarkenton, Chris; Paddock, David A.; Smeltzer, Stanley S.; Ghose, Sayata; Guzman, Juan C.; Stukus, Donald J.; McCarville, Douglas A.

    2013-01-01

    The development of durable bonded joint technology for assembling composite structures is an essential component of future space technologies. While NASA is working toward providing an entirely new capability for human space exploration beyond low Earth orbit, the objective of this project is to design, fabricate, analyze, and test a NASA patented durable redundant joint (DRJ) and a NASA/Boeing co-designed fluted-core joint (FCJ). The potential applications include a wide range of sandwich structures for NASA's future launch vehicles. Three types of joints were studied -- splice joint (SJ, as baseline), DRJ, and FCJ. Tests included tension, after-impact tension, and compression. Teflon strips were used at the joint area to increase failure strength by shifting stress concentration to a less sensitive area. Test results were compared to those of pristine coupons fabricated utilizing the same methods. Tensile test results indicated that the DRJ design was stiffer, stronger, and more impact resistant than other designs. The drawbacks of the DRJ design were extra mass and complex fabrication processes. The FCJ was lighter than the DRJ but less impact resistant. With barely visible but detectable impact damages, all three joints showed no sign of tensile strength reduction. No compression test was conducted on any impact-damaged sample due to limited scope and resource. Failure modes and damage propagation were also studied to support progressive damage modeling of the SJ and the DRJ.

  3. Acromioclavicular joint dislocations: coracoclavicular reconstruction with and without additional direct acromioclavicular repair.

    PubMed

    Weiser, Lukas; Nüchtern, Jakob V; Sellenschloh, Kay; Püschel, Klaus; Morlock, Michael M; Rueger, Johannes M; Hoffmann, Michael; Lehmann, Wolfgang; Großterlinden, Lars G

    2017-07-01

    To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20-70 N and vertical load to failure determined after cyclic testing. Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.

  4. Automated inspection of solder joints for surface mount technology

    NASA Technical Reports Server (NTRS)

    Savage, Robert M.; Park, Hyun Soo; Fan, Mark S.

    1993-01-01

    Researchers at NASA/GSFC evaluated various automated inspection systems (AIS) technologies using test boards with known defects in surface mount solder joints. These boards were complex and included almost every type of surface mount device typical of critical assemblies used for space flight applications: X-ray radiography; X-ray laminography; Ultrasonic Imaging; Optical Imaging; Laser Imaging; and Infrared Inspection. Vendors, representative of the different technologies, inspected the test boards with their particular machine. The results of the evaluation showed limitations of AIS. Furthermore, none of the AIS technologies evaluated proved to meet all of the inspection criteria for use in high-reliability applications. It was found that certain inspection systems could supplement but not replace manual inspection for low-volume, high-reliability, surface mount solder joints.

  5. Adaptive plasticity in mammalian masticatory joints

    NASA Astrophysics Data System (ADS)

    Ravosa, Matthew J.; Kunwar, Ravinder; Nicholson, Elisabeth K.; Klopp, Emily B.; Pinchoff, Jessie; Stock, Stuart R.; Stack, M. Sharon; Hamrick, Mark W.

    2006-08-01

    Genetically similar white rabbits raised on diets of different mechanical properties, as well as wild-type and myostatin-deficient mice raised on similar diets, were compared to assess the postweaning effects of elevated masticatory loads due to increased jaw-adductor muscle and bite forces on the proportions and properties of the mandibular symphysis and temporomandibular joint (TMJ). Microcomputed tomography (microCT) was used to quantify bone structure at a series of equidistant external and internal sites in coronal sections for a series of joint locations. Discriminant function analyses and non-parametric ANOVAs were used to characterize variation in biomineralization within and between loading cohorts. In both species, long-term excessive loading results in larger joint proportions, thicker articular and cortical bone, and increased biomineralization of hard tissues. Such adaptive plasticity appears designed to maintain the postnatal integrity of masticatory joint systems for a primary loading environment(s). This behavioral signal may be increasingly mitigated in older organisms by the interplay between adaptive and degradative joint tissue responses.

  6. Atypical prefrontal cortical responses to joint/non-joint attention in children with autism spectrum disorder (ASD): A functional near-infrared spectroscopy study

    PubMed Central

    Zhu, Huilin; Li, Jun; Fan, Yuebo; Li, Xinge; Huang, Dan; He, Sailing

    2015-01-01

    Autism spectrum disorder (ASD) is a neuro-developmental disorder, characterized by impairments in one’s capacity for joint attention. In this study, functional near-infrared spectroscopy (fNIRS) was applied to study the differences in activation and functional connectivity in the prefrontal cortex between children with autism spectrum disorder (ASD) and typically developing (TD) children. 21 ASD and 20 TD children were recruited to perform joint and non-joint attention tasks. Compared with TD children, children with ASD showed reduced activation and atypical functional connectivity pattern in the prefrontal cortex during joint attention. The atypical development of left prefrontal cortex might play an important role in social cognition defects of children with ASD. PMID:25798296

  7. Arthrodesis of the thumb interphalangeal joint and finger distal interphalangeal joints with a headless compression screw.

    PubMed

    Cox, Christopher; Earp, Brandon E; Floyd, W Emerson; Blazar, Philip E

    2014-01-01

    To study the results of using a small, headless compression screw (AcuTwist) for thumb interphalangeal (IP) joint and finger distal interphalangeal (DIP) joint arthrodeses. Between November 2007 and January 2012, 48 primary arthrodeses of the thumb IP joint or DIP joint in the other digits were performed in 29 consecutive patients with AcuTwist devices. Indications for arthrodesis included 19 cases of osteoarthritis in 25 fingers, 3 cases of lupus in 9 fingers, 2 cases of post-traumatic osteoarthritis in 2 fingers, and 1 case and finger each of acute trauma, neuromuscular disorder, postinfectious osteoarthritis, boutonniere deformity, and Dupuytren contracture. Charts were reviewed for clinical data, and radiographs were assessed for alignment and healing. Age averaged 59 years and follow-up averaged 12 months (range, 2-50 mo). Union occurred in 43 out of 46 fingers (94%). There were no cases of nail deformity, wound complications, tip hypersensitivity, or clinically notable malalignment. Three arthrodeses failed to fuse, including 2 asymptomatic nonunions and 1 fixation loss requiring revision with autograft. The complication rate was 9%. Distal digital joint arthrodesis with the AcuTwist resulted in a fusion rate of 94% with a complication rate of 9%. Our rate of fusion compares favorably with prior series using other methods of fixation. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. IRS memorandum limits joint ventures.

    PubMed

    Herman, A W

    1992-08-01

    Based on a new memorandum, the Internal Revenue Service (IRS) will be looking at joint hospital/physician activities with greater attention to the nuances of public versus private benefit. As a result, hospitals face greater risk of losing their tax-exempt status in the maze of joint ventures, physician recruitment, and practice acquisition. To be successful, ventures will have to be backed by sound reasoning and thorough documentation.

  9. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  10. Why Do Staff of Joint-Use Libraries Sometimes Fail to Integrate? Investigating Cultures and Ethics in a Public-Tertiary Joint-Use Library

    ERIC Educational Resources Information Center

    Calvert, Philip James

    2010-01-01

    Joint-use libraries have identified staff integration as a problem. Using focus groups, this project investigated the culture, professional ethics, and attitudes of staff in a public-tertiary joint-use library in Auckland, New Zealand. Findings show some difference in organizational cultures, but more variation at the lower level of roles and…

  11. Joint sealant study

    DOT National Transportation Integrated Search

    1987-09-01

    ADOT has approximately 550 lane miles of jointed portland cement pavement under its jurisdiction. The current practice is to saw and seal the joints at the time of construction and reseal the joints under a rehabilitation project. ADOT does not speci...

  12. Interdependence of torque, joint angle, angular velocity and muscle action during human multi-joint leg extension.

    PubMed

    Hahn, Daniel; Herzog, Walter; Schwirtz, Ansgar

    2014-08-01

    Force and torque production of human muscles depends upon their lengths and contraction velocity. However, these factors are widely assumed to be independent of each other and the few studies that dealt with interactions of torque, angle and angular velocity are based on isolated single-joint movements. Thus, the purpose of this study was to determine force/torque-angle and force/torque-angular velocity properties for multi-joint leg extensions. Human leg extension was investigated (n = 18) on a motor-driven leg press dynamometer while measuring external reaction forces at the feet. Extensor torque in the knee joint was calculated using inverse dynamics. Isometric contractions were performed at eight joint angle configurations of the lower limb corresponding to increments of 10° at the knee from 30 to 100° of knee flexion. Concentric and eccentric contractions were performed over the same range of motion at mean angular velocities of the knee from 30 to 240° s(-1). For contractions of increasing velocity, optimum knee angle shifted from 52 ± 7 to 64 ± 4° knee flexion. Furthermore, the curvature of the concentric force/torque-angular velocity relations varied with joint angles and maximum angular velocities increased from 866 ± 79 to 1,238 ± 132° s(-1) for 90-50° knee flexion. Normalised eccentric forces/torques ranged from 0.85 ± 0.12 to 1.32 ± 0.16 of their isometric reference, only showing significant increases above isometric and an effect of angular velocity for joint angles greater than optimum knee angle. The findings reveal that force/torque production during multi-joint leg extension depends on the combined effects of angle and angular velocity. This finding should be accounted for in modelling and optimisation of human movement.

  13. Rate dependent strengths of some solder joints

    NASA Astrophysics Data System (ADS)

    Williamson, D. M.; Field, J. E.; Palmer, S. J. P.; Siviour, C. R.

    2007-08-01

    The shear strengths of three lead-free solder joints have been measured over the range of loading rates 10-3 to ~105 mm min-1. Binary (SnAg), ternary (SnAgCu) and quaternary (Castin: SnAgCuSb) alloys have been compared to a conventional binary SnPb solder alloy. Results show that at loading rates from 10-3 to 102 mm min-1, all four materials exhibit a linear relationship between the shear strength and the loading rate when the data are plotted on a log-log plot. At the highest loading rate of 105 mm min-1, the strengths of the binary alloys were in agreement with extrapolations made from the lower loading rate data. In contrast, the strengths of the higher order alloys were found to be significantly lower than those predicted by extrapolation. This is explained by a change in failure mechanism on the part of the higher order alloys. Similar behaviour was found in measurements of the tensile strengths of solder joints using a novel high-rate loading tensile test. Optical and electron microscopy were used to examine the microstructures of interest in conjunction with energy dispersive x-ray analysis for elemental identification. The effect of artificial aging and reflow of the solder joints is also reported.

  14. Operative tactics and results of treatment of patients with coxarthrosis secondary to congenital high luxation of hip joints.

    PubMed

    Król, Roman; Rojewski, Marek; Kamiński, Adam; Popławski, Tomasz

    2007-01-01

    Treatment of the sequelae of congenital high luxation of the hip joint is a major challenge in prosthetic surgery, demanding from the operator thorough familiarity with the problem and experience in hop reconstructive surgery. The results of 4 years observation, of the treatment of 14 woman in the average age of 38 years old with 18 hip joints with congenital high luxation are presented. In all cases cementless total hip arthroplasty was made. Acetabular component of the prosthesis was implanted correctly and stable in its physiological placement. Femur was shortened average 4 cm and stabilized by cementless press-fit stem of prosthesis. The place of femur osteotomy was covered with autogenic spongy bone from resected caput of femur. The union was achieved after average 10 weeks. In clinical assessment there were obtained 10 very good, 5 good and 3 satisfactory clinical results. There were no superficial or deep infections, no neurological disorders and no loosening of components of implanted prostheses observed. 1. Careful planning and carrying out the operative procedures allow to insert the acetabular component of the prosthesis in its physiological place and achieve good results. 2. Shortening of femur and repositioning of components of prosthesis in 90 degrees knee flexion and also position on broken bed after operative procedure allowed to avoid neurological disorders. 3. Cementless and hydroxyapatite-covered femoral component of the prosthesis correctly stabilize place of femur osteotomy.

  15. Analysis of Network Vulnerability Under Joint Node and Link Attacks

    NASA Astrophysics Data System (ADS)

    Li, Yongcheng; Liu, Shumei; Yu, Yao; Cao, Ting

    2018-03-01

    The security problem of computer network system is becoming more and more serious. The fundamental reason is that there are security vulnerabilities in the network system. Therefore, it’s very important to identify and reduce or eliminate these vulnerabilities before they are attacked. In this paper, we are interested in joint node and link attacks and propose a vulnerability evaluation method based on the overall connectivity of the network to defense this attack. Especially, we analyze the attack cost problem from the attackers’ perspective. The purpose is to find the set of least costs for joint links and nodes, and their deletion will lead to serious network connection damage. The simulation results show that the vulnerable elements obtained from the proposed method are more suitable for the attacking idea of the malicious persons in joint node and link attack. It is easy to find that the proposed method has more realistic protection significance.

  16. Bone alterations are associated with ankle osteoarthritis joint pain

    PubMed Central

    Nakamura, Yukio; Uchiyama, Shigeharu; Kamimura, Mikio; Komatsu, Masatoshi; Ikegami, Shota; Kato, Hiroyuki

    2016-01-01

    The etiology of ankle osteoarthritis (OA) is largely unknown. We analyzed 24 ankle OA of 21 patients diagnosed by plain radiographs using magnetic resonance imaging (MRI). Ankle joint pain disappeared in 22 out of 24 joints by conservative treatment. MRI bone signal changes in and around the ankle joints were observed in 22 of 24 joints. Bone signal changes along the joint line were seen in 10 of 11 joints as a Kellgren-Lawrence (KL) grade of II to IV. Such signal changes were witnessed in only 4 of 13 joints with KL grade 0 or I. In the talocrural joint, bone alterations occurred in both tibia and talus bones through the joint line in cases of KL grade III or IV, while focal bone alterations were present in the talus only in KL grade I or II cases. Sixteen of 24 joints exhibited intraosseous bone signal changes, which tended to correspond to joint pain of any ankle OA stage. Our results suggest that bone alterations around the ankle joint might be one of the etiologies of OA and associated with ankle joint pain. PMID:26776564

  17. Bone alterations are associated with ankle osteoarthritis joint pain.

    PubMed

    Nakamura, Yukio; Uchiyama, Shigeharu; Kamimura, Mikio; Komatsu, Masatoshi; Ikegami, Shota; Kato, Hiroyuki

    2016-01-18

    The etiology of ankle osteoarthritis (OA) is largely unknown. We analyzed 24 ankle OA of 21 patients diagnosed by plain radiographs using magnetic resonance imaging (MRI). Ankle joint pain disappeared in 22 out of 24 joints by conservative treatment. MRI bone signal changes in and around the ankle joints were observed in 22 of 24 joints. Bone signal changes along the joint line were seen in 10 of 11 joints as a Kellgren-Lawrence (KL) grade of II to IV. Such signal changes were witnessed in only 4 of 13 joints with KL grade 0 or I. In the talocrural joint, bone alterations occurred in both tibia and talus bones through the joint line in cases of KL grade III or IV, while focal bone alterations were present in the talus only in KL grade I or II cases. Sixteen of 24 joints exhibited intraosseous bone signal changes, which tended to correspond to joint pain of any ankle OA stage. Our results suggest that bone alterations around the ankle joint might be one of the etiologies of OA and associated with ankle joint pain.

  18. Joint Blind Source Separation by Multi-set Canonical Correlation Analysis

    PubMed Central

    Li, Yi-Ou; Adalı, Tülay; Wang, Wei; Calhoun, Vince D

    2009-01-01

    In this work, we introduce a simple and effective scheme to achieve joint blind source separation (BSS) of multiple datasets using multi-set canonical correlation analysis (M-CCA) [1]. We first propose a generative model of joint BSS based on the correlation of latent sources within and between datasets. We specify source separability conditions, and show that, when the conditions are satisfied, the group of corresponding sources from each dataset can be jointly extracted by M-CCA through maximization of correlation among the extracted sources. We compare source separation performance of the M-CCA scheme with other joint BSS methods and demonstrate the superior performance of the M-CCA scheme in achieving joint BSS for a large number of datasets, group of corresponding sources with heterogeneous correlation values, and complex-valued sources with circular and non-circular distributions. We apply M-CCA to analysis of functional magnetic resonance imaging (fMRI) data from multiple subjects and show its utility in estimating meaningful brain activations from a visuomotor task. PMID:20221319

  19. Experimental investigation of the dynamic installation of a slip joint connection between the monopile and tower of an offshore wind turbine

    NASA Astrophysics Data System (ADS)

    Segeren, M. L. A.; Hermans, K. W.

    2014-06-01

    The failure of the traditional grouted connections of offshore wind turbines has led to the investigation of alternatives that provide a connection between the foundation pile and the turbine tower. An alternative to the traditional joint is a steel-to-steel connection also called a slip joint. To ensure a proper fit of the slip joint a dynamic installation of the joint is proposed. In this contribution, the effectiveness of harmonic excitation as an installation procedure is experimentally investigated using a 1:10 scaled model of the joint. During the dynamic installation test the applied static load, settlements and dynamic response of the joint are monitored using respectively load cells, taut wires and strain gauges placed both inside and outside the conical surfaces. The results show that settlement occurs only when applying a harmonic load at specific forcing frequencies. The settlement stabilizes to a certain level for each of the specific frequencies, indicating that a controlled way of installation is possible. The results show that it is essential to vibrate at specific frequencies and that a larger amplitude of the harmonic force does not automatically lead to additional settlement.

  20. Genetic conditions of joint Nordic genetic evaluations of lifetime competition performance in warmblood sport horses.

    PubMed

    Viklund, Å; Furre, S; Eriksson, S; Vangen, O; Philipsson, J

    2015-08-01

    Breeding programmes for warmblood sport horses are similar in the Nordic countries Sweden, Denmark, Finland and Norway, and stallions of same origin are used. The aim was to investigate whether a joint Nordic genetic evaluation based on lifetime competition performance is feasible and beneficial for breeding competitive sport horses in the Nordic countries. Results for almost 45,000 horses in show jumping and 30,000 horses in dressage were available. The larger populations in Sweden and Denmark contributed with 85% of the results. Heritabilities and genetic correlations between performances in the different countries were estimated, and comparisons of accuracies of estimated breeding values (EBVs) and number of stallions with EBVs based on national or joint data were studied. The heritabilities ranged between 0.25 and 0.42 for show jumping and between 0.14 and 0.55 for dressage. The genetic correlations between competition performances in the Nordic countries were estimated to 0.63-1.00. EBVs based on joint data increased accuracies for EBVs for stallions by 38-81% and increased the number of available stallions with EBVs by 40-288%, compared to EBVs based on national data only. A joint Nordic genetic evaluation for sport horses is recommended. © 2015 Blackwell Verlag GmbH.

  1. Clinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis

    PubMed Central

    Inoue, Daisuke; Kajino, Yoshitomo; Taga, Tadashi; Yamamoto, Takashi; Takagi, Tomoharu

    2018-01-01

    Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short- to mid-term results can be achieved by improving the durability of the implant. This paper reports the mid- to long-term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X-rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis. PMID:29666733

  2. Autonomy and control in dyads: effects on interaction quality and joint creative performance.

    PubMed

    Weinstein, Netta; Hodgins, Holley S; Ryan, Richard M

    2010-12-01

    Two studies examined interaction quality and joint performance on two creative tasks in unacquainted dyads primed for autonomy or control orientations. It was hypothesized that autonomy-primed dyads would interact more constructively, experience more positive mood, and engage the task more readily, and as a result these dyads would perform better. To test this, Study 1 primed orientation and explored verbal creative performance on the Remote Associates Task (RAT). In Study 2, dyads were primed with autonomy and control orientation and videotaped during two joint creative tasks, one verbal (RAT) and one nonverbal (charades). Videotapes were coded for behavioral indicators of closeness and task engagement. Results showed that autonomy-primed dyads felt closer, were more emotionally and cognitively attuned, provided empathy and encouragement to partners, and performed more effectively. The effects of primed autonomy on creative performance were mediated by interpersonal quality, mood, and joint engagement.

  3. Impact of Acid Attack on the Shear Behaviour of a Carbonate Rock Joint

    NASA Astrophysics Data System (ADS)

    Nouailletas, O.; Perlot, C.; Rivard, P.; Ballivy, G.; La Borderie, C.

    2017-06-01

    The mechanical behaviour of structural discontinuities in rock mass is a key element of the stability analysis in civil engineering, petroleum engineering and mining engineering. In this paper, the mechanical analysis is coupled with the acidic attack of a rock joint associated with leakage of CO2 through a geological fault in the context of carbon sequestration. Experiments were conducted at the laboratory scale to assess the shear behaviour of degraded joint: direct shear tests were performed on rock joints that have been previously immersed into water or into an acidic solution (pH 0.2). The shear behaviour of joints is governed by the roughness of its walls: the parameters Z2, Z3, Z4 and RL characterize the rough surfaces. They are calculated from the scans of joint surfaces after and before immersion. Their comparison pointed out a slight impact of the acidic attack. However, the results of the direct shear tests show significant modifications in the shear behaviour for the degraded joints: the tangential stress peak disappears, the tangential stiffness decreases in the stress/displacement curve, and the contraction increases, the dilation angle decreases in the dilation curve. Acid attack has a greater impact on the mechanical properties of the asperities than their geometric characteristics. The results of this study will be used to improve chemo-mechanical modelling to better simulate with higher accuracy the fault stability in different cases of civil engineering, petroleum engineering and mining engineering.

  4. Joint Polar Satellite System

    NASA Technical Reports Server (NTRS)

    Trenkle, Timothy; Driggers, Phillip

    2011-01-01

    The Joint Polar Satellite System (JPSS) is a joint NOAA/NASA mission comprised of a series of polar orbiting weather and climate monitoring satellites which will fly in a sun-synchronous orbit, with a 1330 equatorial crossing time. JPSS resulted from the decision to reconstitute the National Polar-orbiting Operational Environmental Satellite System (NPOESS) into two separate programs, one to be run by the Department of Defense (DOD) and the other by NOAA. This decision was reached in early 2010, after numerous development issues caused a series of unacceptable delays in launching the NPOESS system.

  5. Measurement of body joint angles for physical therapy based on mean shift tracking using two low cost Kinect images.

    PubMed

    Chen, Y C; Lee, H J; Lin, K H

    2015-08-01

    Range of motion (ROM) is commonly used to assess a patient's joint function in physical therapy. Because motion capture systems are generally very expensive, physical therapists mostly use simple rulers to measure patients' joint angles in clinical diagnosis, which will suffer from low accuracy, low reliability, and subjective. In this study we used color and depth image feature from two sets of low-cost Microsoft Kinect to reconstruct 3D joint positions, and then calculate moveable joint angles to assess the ROM. A Gaussian background model is first used to segment the human body from the depth images. The 3D coordinates of the joints are reconstructed from both color and depth images. To track the location of joints throughout the sequence more precisely, we adopt the mean shift algorithm to find out the center of voxels upon the joints. The two sets of Kinect are placed three meters away from each other and facing to the subject. The joint moveable angles and the motion data are calculated from the position of joints frame by frame. To verify the results of our system, we take the results from a motion capture system called VICON as golden standard. Our 150 test results showed that the deviation of joint moveable angles between those obtained by VICON and our system is about 4 to 8 degree in six different upper limb exercises, which are acceptable in clinical environment.

  6. Reliability of a smartphone-based goniometer for knee joint goniometry.

    PubMed

    Ferriero, Giorgio; Vercelli, Stefano; Sartorio, Francesco; Muñoz Lasa, Susana; Ilieva, Elena; Brigatti, Elisa; Ruella, Carolina; Foti, Calogero

    2013-06-01

    The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.

  7. Aircraft and ground vehicle friction correlation test results obtained under winter runway conditions during joint FAA/NASA Runway Friction Program

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.; Vogler, William A.; Baldasare, Paul

    1988-01-01

    Aircraft and ground vehicle friction data collected during the Joint FAA/NASA Runway Friction Program under winter runway conditions are discussed and test results are summarized. The relationship between the different ground vehicle friction measurements obtained on compacted snow- and ice-covered conditions is defined together with the correlation to aircraft tire friction performance under similar runway conditions.

  8. Investigation of Hydrogen Embrittlement Susceptibility of X80 Weld Joints by Thermal Simulation

    NASA Astrophysics Data System (ADS)

    Peng, Huangtao; An, Teng; Zheng, Shuqi; Luo, Bingwei; Wang, Siyu; Zhang, Shuai

    2018-05-01

    The objective of this study was to investigate the hydrogen embrittlement (HE) susceptibility and influence mechanism of X80 weld joints. Slow strain rate testing (SSRT) under in situ H-charging, combined with microstructure and fracture analysis, was performed on the base metal (BM), weld metal (WM), thermally simulated fine-grained heat-affected zone (FGHAZ) and coarse-grained heat-affected zone (CGHAZ). Results showed that the WM and simulated HAZ had a greater degree of high local strain distribution than the BM; compared to the CGHAZ, the FGHAZ had lower microhardness and more uniformly distributed stress. SSRT results showed that the weld joint was highly sensitive to HE; the HE index decreased in the following sequence: FGHAZ, WM, CGHAZ and BM. The effect of the microstructure on HE was mainly reflected in microstructure, local stress distribution and microhardness.

  9. Taking two to tango: fMRI analysis of improvised joint action with physical contact

    PubMed Central

    Belyk, Michel; Brown, Steven

    2018-01-01

    Many forms of joint action involve physical coupling between the participants, such as when moving a sofa together or dancing a tango. We report the results of a novel two-person functional MRI study in which trained couple dancers engaged in bimanual contact with an experimenter standing next to the bore of the magnet, and in which the two alternated between being the leader and the follower of joint improvised movements. Leading showed a general pattern of self-orientation, being associated with brain areas involved in motor planning, navigation, sequencing, action monitoring, and error correction. In contrast, following showed a far more sensory, externally-oriented pattern, revealing areas involved in somatosensation, proprioception, motion tracking, social cognition, and outcome monitoring. We also had participants perform a “mutual” condition in which the movement patterns were pre-learned and the roles were symmetric, thereby minimizing any tendency toward either leading or following. The mutual condition showed greater activity in brain areas involved in mentalizing and social reward than did leading or following. Finally, the analysis of improvisation revealed the dual importance of motor-planning and working-memory areas. We discuss these results in terms of theories of both joint action and improvisation. PMID:29324862

  10. Results of the fourth joint U.S.-Russian Bering and Chukchi Seas expedition (BERPAC)

    USDA-ARS?s Scientific Manuscript database

    It is important to monitor the status of arctic oceans especially in terms of the impact human activities are making on these sensitive ecosystems. This is a compilation of research findings from a joint US/Russian expedition to the Bering and Chukchi seas that focuses on the significance of long-t...

  11. Joint swelling

    MedlinePlus

    ... of arthritis caused by buildup of uric acid crystals in a joint ( gout ) Arthritis caused by wear ... osteoarthritis ) Arthritis caused by buildup of calcium-type crystals in joints ( pseudogout ) Disorder that involves arthritis and ...

  12. Outcome of Joint-Preserving Arthroplasty for Rheumatoid Forefoot Deformities.

    PubMed

    Fukushi, Jun-ichi; Nakashima, Yasuharu; Okazaki, Ken; Yamada, Hisakata; Mawatari, Taro; Ohishi, Masanobu; Oyamada, Akiko; Akasaki, Yukio; Iwamoto, Yukihide

    2016-03-01

    Along with the recent advances in the pharmacological management of rheumatoid arthritis, there is a trend toward the use of joint-preserving surgery in the treatment of rheumatoid forefoot deformities. However, the clinical outcomes of joint-preserving surgery for rheumatoid forefoot deformities have not been assessed in comparison to resection arthroplasty. We retrospectively evaluated 23 feet in 17 patients with rheumatoid forefoot deformities who underwent surgery between January 2010 and December 2013. The patients included 1 male (1 foot) and 16 females (22 feet), with a mean age of 62 years. The mean length of follow-up was 28 months. The patients were treated by 3 surgeons. One surgeon performed joint-preserving procedures (JP group) to the feet in which (1) no pain with motion existed, and (2) the range of motion in the first metatarsophalangeal (MTP) joint was greater than 30 degrees (n = 10); otherwise, resection arthroplasty with arthrodesis of the first MTP joint was performed (n = 3). The other surgeons performed resection arthroplasty in all cases (n = 10) (RA group, n = 13 in total). The clinical outcomes of the patients were evaluated using the Japanese Society for Surgery of the Foot (JSSF) hallux and lesser toe scales. There were no significant differences in the preoperative total JSSF scores for either the hallux (54.5 and 61.4 points) or the lesser toe (45.2 and 57.4 points) between the RA and JP groups, respectively. Postoperatively, the total JSSF scores for both the hallux (79.4 and 88.2 points) and lesser toes (73.6 and 87.7 points) showed significant improvement in both the RA and JP groups, respectively; however, the JP group showed a greater postoperative improvement. The scores relating to the function category on the hallux scale and the alignment category on the lesser toe scale were significantly higher in the JP group. With regard to the function of the hallux and the alignment of the lesser toes, the joint-preserving procedures

  13. Kinematics fingerprints of leader and follower role-taking during cooperative joint actions.

    PubMed

    Sacheli, Lucia Maria; Tidoni, Emmanuele; Pavone, Enea Francesco; Aglioti, Salvatore Maria; Candidi, Matteo

    2013-05-01

    Performing online complementary motor adjustments is quintessential to joint actions since it allows interacting people to coordinate efficiently and achieve a common goal. We sought to determine whether, during dyadic interactions, signaling strategies and simulative processes are differentially implemented on the basis of the interactional role played by each partner. To this aim, we recorded the kinematics of the right hand of pairs of individuals who were asked to grasp as synchronously as possible a bottle-shaped object according to an imitative or complementary action schedule. Task requirements implied an asymmetric role assignment so that participants performed the task acting either as (1) Leader (i.e., receiving auditory information regarding the goal of the task with indications about where to grasp the object) or (2) Follower (i.e., receiving instructions to coordinate their movements with their partner's by performing imitative or complementary actions). Results showed that, when acting as Leader, participants used signaling strategies to enhance the predictability of their movements. In particular, they selectively emphasized kinematic parameters and reduced movement variability to provide the partner with implicit cues regarding the action to be jointly performed. Thus, Leaders make their movements more "communicative" even when not explicitly instructed to do so. Moreover, only when acting in the role of Follower did participants tend to imitate the Leader, even in complementary actions where imitation is detrimental to joint performance. Our results show that mimicking and signaling are implemented in joint actions according to the interactional role of the agent, which in turn is reflected in the kinematics of each partner.

  14. Joint modelling rationale for chained equations

    PubMed Central

    2014-01-01

    Background Chained equations imputation is widely used in medical research. It uses a set of conditional models, so is more flexible than joint modelling imputation for the imputation of different types of variables (e.g. binary, ordinal or unordered categorical). However, chained equations imputation does not correspond to drawing from a joint distribution when the conditional models are incompatible. Concurrently with our work, other authors have shown the equivalence of the two imputation methods in finite samples. Methods Taking a different approach, we prove, in finite samples, sufficient conditions for chained equations and joint modelling to yield imputations from the same predictive distribution. Further, we apply this proof in four specific cases and conduct a simulation study which explores the consequences when the conditional models are compatible but the conditions otherwise are not satisfied. Results We provide an additional “non-informative margins” condition which, together with compatibility, is sufficient. We show that the non-informative margins condition is not satisfied, despite compatible conditional models, in a situation as simple as two continuous variables and one binary variable. Our simulation study demonstrates that as a consequence of this violation order effects can occur; that is, systematic differences depending upon the ordering of the variables in the chained equations algorithm. However, the order effects appear to be small, especially when associations between variables are weak. Conclusions Since chained equations is typically used in medical research for datasets with different types of variables, researchers must be aware that order effects are likely to be ubiquitous, but our results suggest they may be small enough to be negligible. PMID:24559129

  15. VES/TEM 1D joint inversion by using Controlled Random Search (CRS) algorithm

    NASA Astrophysics Data System (ADS)

    Bortolozo, Cassiano Antonio; Porsani, Jorge Luís; Santos, Fernando Acácio Monteiro dos; Almeida, Emerson Rodrigo

    2015-01-01

    Electrical (DC) and Transient Electromagnetic (TEM) soundings are used in a great number of environmental, hydrological, and mining exploration studies. Usually, data interpretation is accomplished by individual 1D models resulting often in ambiguous models. This fact can be explained by the way as the two different methodologies sample the medium beneath surface. Vertical Electrical Sounding (VES) is good in marking resistive structures, while Transient Electromagnetic sounding (TEM) is very sensitive to conductive structures. Another difference is VES is better to detect shallow structures, while TEM soundings can reach deeper layers. A Matlab program for 1D joint inversion of VES and TEM soundings was developed aiming at exploring the best of both methods. The program uses CRS - Controlled Random Search - algorithm for both single and 1D joint inversions. Usually inversion programs use Marquadt type algorithms but for electrical and electromagnetic methods, these algorithms may find a local minimum or not converge. Initially, the algorithm was tested with synthetic data, and then it was used to invert experimental data from two places in Paraná sedimentary basin (Bebedouro and Pirassununga cities), both located in São Paulo State, Brazil. Geoelectric model obtained from VES and TEM data 1D joint inversion is similar to the real geological condition, and ambiguities were minimized. Results with synthetic and real data show that 1D VES/TEM joint inversion better recovers simulated models and shows a great potential in geological studies, especially in hydrogeological studies.

  16. [Case control study of fractures-dislocations of ankle joint with conservative and operative treatment].

    PubMed

    Zhang, Song-Tu; Lin, Yi-Rong; Chen, Lian-Yuan

    2010-10-01

    To compare the clinical efficacy of grade III, IV supination-eversion fractures-dislocations of ankle joint between manipulative treatment and operative treatment. From September 2007 to December 2008, the clinical data of 60 patients with grade III, IV supination-eversion fractures-dislocations of ankle joint were retrospectively analyzed. There were 32 males and 28 females, ranging in age from 18 to 70 years with an average age of 38.17 years. All patients were respectively treated with manipulative treatment (conservative group, 30 cases) and operative treatment (operative group, 30 cases). The joint function was compared with Mazur standard; the reduction and shifting of fractures were observed with X-ray; the hospitalization day and the therapeutic cost were compared between two groups. All patients were followed up with an average of 15.27 months (ranged, 6 to 25 months). In conservative group, 16 cases got excellent result in joint function, 10 good, 3 fair, 1 poor; in operative group, 20 cases got excellent result, 8 good, 2 fair, 0 poor. In conservative group in the X-ray showed 25 cases obtained excellent and good reduction, 4 fair, 1 poor; and in operative group in the X-ray showed 28 cases obtained excellent and good reduction, 2 fair, 0 poor. There was no significant difference at the joint function and X-ray film after treatment between two groups (P > 0.05). The hospital day was respectively (7.87 +/- 3.34), (17.37 +/- 4.64) d in conservative group and operative group; and the therapeutic cost was respectively (2 506.67 +/- 649.10), (11 473.33 +/- 1 564.90) yuan. There was significant difference at hospital day and therapeutic cost between two groups (P < 0.05). Conservative treatment and operative treatment can both reach a very good result in treating grade III, IV supination-eversion fractures and dislocations of ankle joint. However, conservative treatment has advantage of high safety factor, low therapeutic cost, can reduce medical costs for

  17. The joint flanker effect and the joint Simon effect: On the comparability of processes underlying joint compatibility effects.

    PubMed

    Dittrich, Kerstin; Bossert, Marie-Luise; Rothe-Wulf, Annelie; Klauer, Karl Christoph

    2017-09-01

    Previous studies observed compatibility effects in different interference paradigms such as the Simon and flanker task even when the task was distributed across two co-actors. In both Simon and flanker tasks, performance is improved in compatible trials relative to incompatible trials if one actor works on the task alone as well as if two co-actors share the task. These findings have been taken to indicate that actors automatically co-represent their co-actor's task. However, recent research on the joint Simon and joint flanker effect suggests alternative non-social interpretations. To which degree both joint effects are driven by the same underlying processes is the question of the present study, and it was scrutinized by manipulating the visibility of the co-actor. While the joint Simon effect was not affected by the visibility of the co-actor, the joint flanker effect was reduced when participants did not see their co-actors but knew where the co-actors were seated. These findings provide further evidence for a spatial interpretation of the joint Simon effect. In contrast to recent claims, however, we propose a new explanation of the joint flanker effect that attributes the effect to an impairment in the focusing of spatial attention contingent on the visibility of the co-actor.

  18. Delamination and Stitched Failure in Stitched Composite Joints

    NASA Technical Reports Server (NTRS)

    Glaessgen, E. H.; Raju, I. S.; Poe, C. C., Jr.

    1999-01-01

    The effect of stitches on the failure of a single lap joint configuration was determined in a combined experimental and finite element study. The experimental program was conducted to determine debond growth under static monotonic loading. The stitches were shown to delay the initiation of the debond and provide load transfer beyond the load necessary to completely debond the stitched lap joint. The experimentally determined debond length vs. applied load was used as an input parameter in the finite element analysis of both configurations. The strain energy release rates at the debond from were calculated using plate finite elements. Nonlinear fastener elements were used to model the stitches and multipoint constraints were used to model the contact problem. Models of the unstitched configuration showed significant values of modes I and II across the width of the joint and showed that mode III is zero at the centerline but increases near the free edge. Models of the stitched configuration showed that the stitches were effective in reducing mode I to zero, but had less of an effect on modes II and III.

  19. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    NASA Astrophysics Data System (ADS)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  20. Topical versus systemic diclofenac in the treatment of temporo-mandibular joint dysfunction symptoms.

    PubMed

    Di Rienzo Businco, L; Di Rienzo Businco, A; D'Emilia, M; Lauriello, M; Coen Tirelli, G

    2004-10-01

    The most frequent symptom of craniomandibular dysfunction is pain in the preauricular area or in the temporo-mandibular joint, usually localized at the level of the masticatory musculature. Patients sometimes also complain of reflect otalgia, headaches and facial pain. Osteoarthrosis is a frequent degenerative debilitating chronic disorder that can affect the temporomandibular joint. It causes pain and articular rigidity, a reduction in mobility, and radiological alterations are visible in stratigraphy. The aim of this study was to compare the efficacy of a topically applied non-steroid anti-inflammatory drug that has recently become commercially available (diclofenac sodium in a patented carrier containing dimethyl sulfoxide, that favours transcutaneous absorption) which is commonly used to alleviate pain in knee or elbow joints, versus oral diclofenac, in the treatment of symptoms of temporomandibular joint dysfunction. Dysfunction of the temporomandibular joint was diagnosed in 36 adult patients. The patients were randomized in two age- and gender -matched groups. Group A (18 patients) received oral diclofenac sodium administered after a meal in 50-mg tablets twice a day for 14 days. Group B (18 patients) received 16 mg/ml topical diclofenac (diclofenac topical solution, 10 drops 4 times a day for 14 days). All patients completed a questionnaire at the start and end of therapy. Patients were asked to quantify on a graded visual analogue scale and to reply to questions about the pain and tenderness of the temporomandibular joint and the functional limitation of mouth opening. Patients were also requested to report side-effects of the treatment. All patients showed relief from pain after treatment: the difference between the two groups was not significant (p > 0.05). Post-treatment, 16 patients of group A had epigastralgic symptoms. Three patients treated with topical diclofenac showed a modest irritation of the temporomandibular joint region, and disappeared

  1. Evaluation of an intact, an ACL-deficient, and a reconstructed human knee joint finite element model.

    PubMed

    Vairis, Achilles; Stefanoudakis, George; Petousis, Markos; Vidakis, Nectarios; Tsainis, Andreas-Marios; Kandyla, Betina

    2016-02-01

    The human knee joint has a three-dimensional geometry with multiple body articulations that produce complex mechanical responses under loads that occur in everyday life and sports activities. Understanding the complex mechanical interactions of these load-bearing structures is of use when the treatment of relevant diseases is evaluated and assisting devices are designed. The anterior cruciate ligament (ACL) in the knee is one of four main ligaments that connects the femur to the tibia and is often torn during sudden twisting motions, resulting in knee instability. The objective of this work is to study the mechanical behavior of the human knee joint and evaluate the differences in its response for three different states, i.e., intact, ACL-deficient, and surgically treated (reconstructed) knee. The finite element models corresponding to these states were developed. For the reconstructed model, a novel repair device was developed and patented by the author in previous work. Static load cases were applied, as have already been presented in a previous work, in order to compare the calculated results produced by the two models the ACL-deficient and the surgically reconstructed knee joint, under the exact same loading conditions. Displacements were calculated in different directions for the load cases studied and were found to be very close to those from previous modeling work and were in good agreement with experimental data presented in literature. The developed finite element model for both the intact and the ACL-deficient human knee joint is a reliable tool to study the kinematics of the human knee, as results of this study show. In addition, the reconstructed human knee joint model had kinematic behavior similar to the intact knee joint, showing that such reconstruction devices can restore human knee stability to an adequate extent.

  2. Management of chronic unstable acromioclavicular joint injuries.

    PubMed

    Cisneros, Luis Natera; Reiriz, Juan Sarasquete

    2017-12-01

    The acromioclavicular joint represents the link between the clavicle and the scapula, which is responsible for the synchronized dynamic of the shoulder girdle. Chronic acromioclavicular joint instability involves changes in the orientation of the scapula, which provokes cinematic alterations that might result in chronic pain. Several surgical strategies for the management of patients with chronic and symptomatic acromioclavicular joint instability have been described. The range of possibilities includes anatomical and non-anatomical techniques, open and arthroscopy-assisted procedures, and biological and synthetic grafts. Surgical management of chronic acromioclavicular joint instability should involve the reconstruction of the torn ligaments because it is accepted that from three weeks after the injury, these structures may lack healing potential. Here, we provide a review of the literature regarding the management of chronic acromioclavicular joint instability. Expert opinion, Level V.

  3. Progressive Damage Analysis of Bonded Composite Joints

    NASA Technical Reports Server (NTRS)

    Leone, Frank A., Jr.; Girolamo, Donato; Davila, Carlos G.

    2012-01-01

    The present work is related to the development and application of progressive damage modeling techniques to bonded joint technology. The joint designs studied in this work include a conventional composite splice joint and a NASA-patented durable redundant joint. Both designs involve honeycomb sandwich structures with carbon/epoxy facesheets joined using adhesively bonded doublers.Progressive damage modeling allows for the prediction of the initiation and evolution of damage within a structure. For structures that include multiple material systems, such as the joint designs under consideration, the number of potential failure mechanisms that must be accounted for drastically increases the complexity of the analyses. Potential failure mechanisms include fiber fracture, intraply matrix cracking, delamination, core crushing, adhesive failure, and their interactions. The bonded joints were modeled using highly parametric, explicitly solved finite element models, with damage modeling implemented via custom user-written subroutines. Each ply was discretely meshed using three-dimensional solid elements. Layers of cohesive elements were included between each ply to account for the possibility of delaminations and were used to model the adhesive layers forming the joint. Good correlation with experimental results was achieved both in terms of load-displacement history and the predicted failure mechanism(s).

  4. Characterization of friction stir welded joint of low nickel austenitic stainless steel and modified ferritic stainless steel

    NASA Astrophysics Data System (ADS)

    Mondal, Mounarik; Das, Hrishikesh; Ahn, Eun Yeong; Hong, Sung Tae; Kim, Moon-Jo; Han, Heung Nam; Pal, Tapan Kumar

    2017-09-01

    Friction stir welding (FSW) of dissimilar stainless steels, low nickel austenitic stainless steel and 409M ferritic stainless steel, is experimentally investigated. Process responses during FSW and the microstructures of the resultant dissimilar joints are evaluated. Material flow in the stir zone is investigated in detail by elemental mapping. Elemental mapping of the dissimilar joints clearly indicates that the material flow pattern during FSW depends on the process parameter combination. Dynamic recrystallization and recovery are also observed in the dissimilar joints. Among the two different stainless steels selected in the present study, the ferritic stainless steels shows more severe dynamic recrystallization, resulting in a very fine microstructure, probably due to the higher stacking fault energy.

  5. Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging

    NASA Astrophysics Data System (ADS)

    Gooda Sahib, M. I.; Leong, S. J.; Chia, C. C.; Mustapha, F.

    2017-12-01

    Joints in aero-mechanical structures are critical elements that ensure the structural integrity but they are prone to damages. Inspection of such joints that have no prior baseline data is really challenging but it can be possibly done using the Ultrasonic Propagation Imager (UPI). The feasibility of applying UPI for detection of loosened fastener is investigated in this study. A simple lap joint specimen made by connecting two pieces of 2.5mm thick SAE304 stainless steel plates using five M6 screws and nuts has been used in this study. All fasteners are tightened to 10Nm but one of them is completely loosened to simulate the damage. The wavefield data is processed into ultrasonic wavefield propagation video and a series of spectral amplitude images. The spectral images showed noticeable amplitude difference at the loosened fastener, hence confirmed the feasibility of using UPI for structural joints inspection. A simple contrast maximization method is also introduced to improve the result.

  6. Size effects in tin-based lead-free solder joints: Kinetics of bond formation and mechanical characteristics

    NASA Astrophysics Data System (ADS)

    Abdelhadi, Ousama Mohamed Omer

    , η-phase (Cu6Sn 5) and epsilon-phase (Cu3Sn), were found in almost all the cases regardless of the process parameters and size levels. The physics-based analytical model was successfully able to capture the governing mechanisms of IMC growth: chemical reaction controlled and diffusion-controlled. Examination of microstructures of solder joints of different sizes revealed the size of the solder joint has no effect on the type of IMCs formed during the process. Joint size, however, affected the thickness of IMC layers significantly. IMC layers formed in the solder joints of smaller sizes were found to be thicker than those in the solder joints of larger sizes. The growth rate constants and activation energies of Cu3Sn IMC layer were also reported and related to joint thickness. In an effort to optimize the EBSD imaging in the multi-layer configuration, an improved specimen preparation technique and optimum software parameters were determined. Nanoindentation results show that size effects play a major role on the mechanical properties of micro-scale solder joints. Smaller joints show higher Young's modulus, hardness, and yield strength and lower work hardening exponents comparing to thicker joints. To obtain the stress concentration factors in a multilayer specimen with IMC layer as bonding material, a four-point bending notched configuration was used. The analytical solutions developed for peeling and shear stresses in notched structure were used to evaluate the stresses at IMC interface layers. Results were in good agreement with the finite-element simulation. The values of interfacial stresses were utilized in obtaining fracture toughness of the IMC material. (Abstract shortened by UMI.)

  7. Mutual coordination strengthens the sense of joint agency in cooperative joint action.

    PubMed

    Bolt, Nicole K; Poncelet, Evan M; Schultz, Benjamin G; Loehr, Janeen D

    2016-11-01

    Philosophers have proposed that when people coordinate their actions with others they may experience a sense of joint agency, or shared control over actions and their effects. However, little empirical work has investigated the sense of joint agency. In the current study, pairs coordinated their actions to produce tone sequences and then rated their sense of joint agency on a scale ranging from shared to independent control. People felt more shared than independent control overall, confirming that people experience joint agency during joint action. Furthermore, people felt stronger joint agency when they (a) produced sequences that required mutual coordination compared to sequences in which only one partner had to coordinate with the other, (b) held the role of follower compared to leader, and (c) were better coordinated with their partner. Thus, the strength of joint agency is influenced by the degree to which people mutually coordinate with each other's actions. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Joint Chiefs of Staff > Leadership

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Structure Joint Staff Organizational Chart Joint Chiefs of Staff Links Home Today in DOD About DOD Top Issues News Photos/Videos

  9. [Injuries of the acromioclavicular joint].

    PubMed

    Meeder, P J; Dannöhl, C

    1988-07-01

    The injuries of the acromio-clavicular joint require a differentiated diagnosis and treatment. The classification of the acromio-clavicular dislocations from grade I to grade III according to Tossy is proved. The diagnosis of a complete acromio-clavicular dislocation (Tossy III) is an indication for a surgical repair. Many and different methods are reported in the literature. 178 patients with a fresh acromio-clavicular dislocation (Typ Tossy II and III) were treated at the BG-Unfallklinik Tübingen from 1970 to 1987 by suturing the ligaments, inserting pins across the joint and tension wire bending. In old cases with Tossy III dislocation of the acromio-clavicular joint an oblique osteotomy combined with the reduction of the clavicle is recommended as a method of choice. The results of these procedures and there possible intra- and postoperative complications are reported. The incision along the clavicle quite often gives scar problems. Therefore the advantages of an arched incision across the acromio-clavicular joint is pointed out. Because of there biomechanical relationship fractures in the lateral third of the clavicle are similar to dislocations of the acromio-clavicular joint. The classification of these fractures according to Jäger, Buschle and Breitner allows a differentiated management of these lesions.

  10. The Preferred Movement Path Paradigm: Influence of Running Shoes on Joint Movement.

    PubMed

    Nigg, Benno M; Vienneau, Jordyn; Smith, Aimée C; Trudeau, Matthieu B; Mohr, Maurice; Nigg, Sandro R

    2017-08-01

    (A) To quantify differences in lower extremity joint kinematics for groups of runners subjected to different running footwear conditions, and (B) to quantify differences in lower extremity joint kinematics on an individual basis for runners subjected to different running footwear conditions. Three-dimensional ankle and knee joint kinematics were collected for 35 heel-toe runners when wearing three different running shoes and when running barefoot. Absolute mean differences in ankle and knee joint kinematics were computed between running shoe conditions. The percentage of individual runners who displayed differences below a 2°, 3°, and 5° threshold were also calculated. The results indicate that the mean kinematics of the ankle and knee joints were similar between running shoe conditions. Aside from ankle dorsiflexion and knee flexion, the percentage of runners maintaining their movement path between running shoes (i.e., less than 3°) was in the order of magnitude of about 80% to 100%. Many runners showed ankle and knee joint kinematics that differed between a conventional running shoe and barefoot by more than 3°, especially for ankle dorsiflexion and knee flexion. Many runners stay in the same movement path (the preferred movement path) when running in various different footwear conditions. The percentage of runners maintaining their preferred movement path depends on the magnitude of the change introduced by the footwear condition.

  11. Towards understanding knee joint laxity: errors in non-invasive assessment of joint rotation can be corrected.

    PubMed

    Moewis, P; Boeth, H; Heller, M O; Yntema, C; Jung, T; Doyscher, R; Ehrig, R M; Zhong, Y; Taylor, W R

    2014-07-01

    The in vivo quantification of rotational laxity of the knee joint is of importance for monitoring changes in joint stability or the outcome of therapies. While invasive assessments have been used to study rotational laxity, non-invasive methods are attractive particularly for assessing young cohorts. This study aimed to determine the conditions under which tibio-femoral rotational laxity can be assessed reliably and accurately in a non-invasive manner. The reliability and error of non-invasive examinations of rotational joint laxity were determined by comparing the artefact associated with surface mounted markers against simultaneous measurements using fluoroscopy in five knees including healthy and ACL deficient joints. The knees were examined at 0°, 30°, 60° and 90° flexion using a device that allows manual axial rotation of the joint. With a mean RMS error of 9.6°, the largest inaccuracy using non-invasive assessment was present at 0° knee flexion, whereas at 90° knee flexion, a smaller RMS error of 5.7° was found. A Bland and Altman assessment indicated that a proportional bias exists between the non-invasive and fluoroscopic approaches, with limits of agreement that exceeded 20°. Correction using average linear regression functions resulted in a reduction of the RMS error to below 1° and limits of agreement to less than ±1° across all knees and flexion angles. Given the excellent reliability and the fact that a correction of the surface mounted marker based rotation values can be achieved, non-invasive evaluation of tibio-femoral rotation could offer opportunities for simplified devices for use in clinical settings in cases where invasive assessments are not justified. Although surface mounted marker based measurements tend to overestimate joint rotation, and therefore joint laxity, our results indicate that it is possible to correct for this error. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Electrical stimulation on joint contracture: an experiment in rat model with direct current.

    PubMed

    Akai, M; Shirasaki, Y; Tateishi, T

    1997-04-01

    To examine whether electrical stimulation could decrease the degree of joint stiffness in a rat lower extremity model. Rat knee joints were surgically immobilized in a flexed position for 3 weeks. Two groups of rats were stimulated with 20 microA and 50 microA constant direct current. Another group had surgical intervention and sham electrodes without electricity. The hind leg was extirpated and prepared for a sample with the femur-knee joint-tibia unit. Recording the knee flexion angle with extension torque, the degree of joint contracture was assessed biomechanically by measuring the bone-joint-bone sample as a cantilever. Measurement was performed with (1) spectral analysis of transfer function measurement using random mechanical noise with frequency range from 1 to 50Hz, and (2) dynamic stiffness and loss tangent with steady-state sinusoidal excitation (11 and 35Hz). The results showed that no significant difference or trend was found in vibration analysis among three groups. However, spectral analysis of transfer function measurement revealed more deformation against load, and more viscous nature in the stimulation groups, especially in low frequency band, than in the sham group. Electrical stimulation with constant direct current has a possibility of reducing the degree of joint contracture.

  13. Radiologic changes of ankle joint after total knee arthroplasty.

    PubMed

    Lee, Jung Hee; Jeong, Bi O

    2012-12-01

    The authors noticed that ankle joint osteoarthritis was not uncommon when lower extremity malalignment, such as a knee varus deformity, was present as a result of severe osteoarthritis of the knee. The purpose of this study was to analyze radiologic changes of the ankle joint after total knee arthroplasty. This study included 142 cases in 110 patients who underwent total knee arthroplasty and were followed for at least 3 years. The varus knee group included 128 cases and the valgus knee group included 14 cases. On anteroposterior standing lower extremity radiographs, varus and valgus angles of the knee were measured preoperatively and at the last follow-up. The angle between the ground surface and the distal tibial plafond as well as the upper talus was also measured. In addition, tibial anterior surface angle, talar tilt, space between the medial malleolar distal tip and the medial articular surface of the talus, and medial tibiotalar joint space of the ankle joint were measured. Out of 142 cases, 50 (35.2%) had arthritis in the ankle before total knee arthroplasty and 31 (21.8%) had newly developed or progressive arthritis after surgery. In particular, the varus knee group demonstrated statistically significant differences in preoperative varus deformity, preoperative talar tilt, and postoperative correction angle between the cases that developed or had progressive arthritis and those that did not show any changes (p < .05). After total knee arthroplasty, arthritis developed or progressed in the ankle of many cases radiographically. In particular, when the preoperative talar tilt increased medial to the ankle or the postoperative correction angle was large, the incidence of arthritis in the ankle joint increased. The authors recommend more cautious follow-up on the symptoms of the ankle joint after total knee arthroplasty.

  14. Influence of groove size and reinforcements addition on mechanical properties and microstructure of friction stir welded joints

    NASA Astrophysics Data System (ADS)

    Reddy Baridula, Ravinder; Ibrahim, Abdullah Bin; Yahya, Che Ku Mohammad Faizal Bin Che Ku; Kulkarni, Ratnakar; Varma Ramaraju, Ramgopal

    2018-03-01

    The butt joints fabricated by friction stir welding were found to have more strength than the joints obtained by conventional joining process. The important outcome of this process is the successful fabrication of surface composites with improved properties. Thus in order to further enhance the strength of the dissimilar alloy joints the reinforcements can be deposited in to the aluminium matrix during the process of friction stir welding. In the present study the multi-walled carbon nanotubes were embedded in to the groove by varying the width during joining of dissimilar alloys AA2024 and AA7075. Four widths were selected with constant depth and optimum process parameters were selected to fabricate the sound welded joints. The results show that the mechanical properties of the fabricated butt joints were influenced by the size of the groove, due to variation in the deposition of reinforcement in the stir zone. The microstructural study and identification of the elements of the welded joints show that the reinforcements deposition is influenced by the size of the groove. It has also been observed that the groove with minimum width is more effective than higher width. The mechanical properties are found to be improved due to the pinning of grain boundaries.

  15. Signaling networks in joint development

    PubMed Central

    Salva, Joanna E.; Merrill, Amy E.

    2016-01-01

    Here we review studies identifying regulatory networks responsible for synovial, cartilaginous, and fibrous joint development. Synovial joints, characterized by the fluid-filled synovial space between the bones, are found in high-mobility regions and are the most common type of joint. Cartilaginous joints unite adjacent bones through either a hyaline cartilage or fibrocartilage intermediate. Fibrous joints, which include the cranial sutures, form a direct union between bones through fibrous connective tissue. We describe how the distinct morphologic and histogenic characteristics of these joint classes are established during embryonic development. Collectively, these studies reveal that despite the heterogeneity of joint strength and mobility, joint development throughout the skeleton utilizes common signaling networks via long-range morphogen gradients and direct cell-cell contact. This suggests that different joint types represent specialized variants of homologous developmental modules. Identifying the unifying aspects of the signaling networks between joint classes allows a more complete understanding of the signaling code for joint formation, which is critical to improving strategies for joint regeneration and repair. PMID:27859991

  16. Kinematics Simulation Analysis of Packaging Robot with Joint Clearance

    NASA Astrophysics Data System (ADS)

    Zhang, Y. W.; Meng, W. J.; Wang, L. Q.; Cui, G. H.

    2018-03-01

    Considering the influence of joint clearance on the motion error, repeated positioning accuracy and overall position of the machine, this paper presents simulation analysis of a packaging robot — 2 degrees of freedom(DOF) planar parallel robot based on the characteristics of high precision and fast speed of packaging equipment. The motion constraint equation of the mechanism is established, and the analysis and simulation of the motion error are carried out in the case of turning the revolute clearance. The simulation results show that the size of the joint clearance will affect the movement accuracy and packaging efficiency of the packaging robot. The analysis provides a reference point of view for the packaging equipment design and selection criteria and has a great significance on the packaging industry automation.

  17. Optimization of joint energy micro-grid with cold storage

    NASA Astrophysics Data System (ADS)

    Xu, Bin; Luo, Simin; Tian, Yan; Chen, Xianda; Xiong, Botao; Zhou, Bowen

    2018-02-01

    To accommodate distributed photovoltaic (PV) curtailment, to make full use of the joint energy micro-grid with cold storage, and to reduce the high operating costs, the economic dispatch of joint energy micro-grid load is particularly important. Considering the different prices during the peak and valley durations, an optimization model is established, which takes the minimum production costs and PV curtailment fluctuations as the objectives. Linear weighted sum method and genetic-taboo Particle Swarm Optimization (PSO) algorithm are used to solve the optimization model, to obtain optimal power supply output. Taking the garlic market in Henan as an example, the simulation results show that considering distributed PV and different prices in different time durations, the optimization strategies are able to reduce the operating costs and accommodate PV power efficiently.

  18. Mechanical performance and parameter sensitivity analysis of 3D braided composites joints.

    PubMed

    Wu, Yue; Nan, Bo; Chen, Liang

    2014-01-01

    3D braided composite joints are the important components in CFRP truss, which have significant influence on the reliability and lightweight of structures. To investigate the mechanical performance of 3D braided composite joints, a numerical method based on the microscopic mechanics is put forward, the modeling technologies, including the material constants selection, element type, grid size, and the boundary conditions, are discussed in detail. Secondly, a method for determination of ultimate bearing capacity is established, which can consider the strength failure. Finally, the effect of load parameters, geometric parameters, and process parameters on the ultimate bearing capacity of joints is analyzed by the global sensitivity analysis method. The results show that the main pipe diameter thickness ratio γ, the main pipe diameter D, and the braided angle α are sensitive to the ultimate bearing capacity N.

  19. One-degree-of-freedom spherical model for the passive motion of the human ankle joint.

    PubMed

    Sancisi, Nicola; Baldisserri, Benedetta; Parenti-Castelli, Vincenzo; Belvedere, Claudio; Leardini, Alberto

    2014-04-01

    Mathematical modelling of mobility at the human ankle joint is essential for prosthetics and orthotic design. The scope of this study is to show that the ankle joint passive motion can be represented by a one-degree-of-freedom spherical motion. Moreover, this motion is modelled by a one-degree-of-freedom spherical parallel mechanism model, and the optimal pivot-point position is determined. Passive motion and anatomical data were taken from in vitro experiments in nine lower limb specimens. For each of these, a spherical mechanism, including the tibiofibular and talocalcaneal segments connected by a spherical pair and by the calcaneofibular and tibiocalcaneal ligament links, was defined from the corresponding experimental kinematics and geometry. An iterative procedure was used to optimize the geometry of the model, able to predict original experimental motion. The results of the simulations showed a good replication of the original natural motion, despite the numerous model assumptions and simplifications, with mean differences between experiments and predictions smaller than 1.3 mm (average 0.33 mm) for the three joint position components and smaller than 0.7° (average 0.32°) for the two out-of-sagittal plane rotations, once plotted versus the full flexion arc. The relevant pivot-point position after model optimization was found within the tibial mortise, but not exactly in a central location. The present combined experimental and modelling analysis of passive motion at the human ankle joint shows that a one degree-of-freedom spherical mechanism predicts well what is observed in real joints, although its computational complexity is comparable to the standard hinge joint model.

  20. Subtalar joint stress imaging with tomosynthesis.

    PubMed

    Teramoto, Atsushi; Watanabe, Kota; Takashima, Hiroyuki; Yamashita, Toshihiko

    2014-06-01

    The purpose of this study was to perform stress imaging of hindfoot inversion and eversion using tomosynthesis and to assess the subtalar joint range of motion (ROM) of healthy subjects. The subjects were 15 healthy volunteers with a mean age of 29.1 years. Coronal tomosynthesis stress imaging of the subtalar joint was performed in a total of 30 left and right ankles. A Telos stress device was used for the stress load, and the load was 150 N for both inversion and eversion. Tomographic images in which the posterior talocalcaneal joint could be confirmed on the neutral position images were used in measurements. The angle of the intersection formed by a line through the lateral articular facet of the posterior talocalcaneal joint and a line through the surface of the trochlea of the talus was measured. The mean change in the angle of the calcaneus with respect to the talus was 10.3 ± 4.8° with inversion stress and 5.0 ± 3.8° with eversion stress from the neutral position. The result was a clearer depiction of the subtalar joint, and inversion and eversion ROM of the subtalar joint was shown to be about 15° in healthy subjects. Diagnostic, Level IV.

  1. Tinnitus in Temporomandibular Joint Disorders: Is it a Specific Somatosensory Tinnitus Subtype?

    PubMed

    Algieri, Giuseppe Maria Antonio; Leonardi, Alessandra; Arangio, Paolo; Vellone, Valentino; Paolo, Carlo Di; Cascone, Piero

    2017-04-19

    The most significant otologic symptoms, consisting of ear pain, tinnitus, dizziness, hearing loss and auricolar "fullness", generally arise within the auditory system, often are associated with extra auricolar disorders, particularly disorder of the temporo-mandibular joint. In our study we examined a sample of 200 consecutive patients who had experienced severe disabling symptom. The patiens came to maxillofacial specialist assessment for temporomandibular disorder. Each patient was assessed by a detailed anamnestic and clinical temporomandibular joint examination and they are divided into five main groups according classification criteria established by Wilkes; tinnitus and subjective indicators of pain are evaluated. The results of this study provide a close correlation between the joint pathology and otologic symptoms, particularly regarding tinnitus and balance disorders, and that this relationship is greater the more advanced is the stage of joint pathology. Moreover, this study shows that TMD-related tinnitus principally affects a younger population (average fifth decade of life) and mainly women (more than 2/3 of the cases). Such evidence suggests the existence of a specific tinnitus subtype that may be defined as "TMD-related somatosensory tinnitus".

  2. Does metaphyseal cement augmentation in fracture management influence the adjacent subchondral bone and joint cartilage?: an in vivo study in sheep stifle joints.

    PubMed

    Goetzen, Michael; Hofmann-Fliri, Ladina; Arens, Daniel; Zeiter, Stephan; Stadelmann, Vincent; Nehrbass, Dirk; Richards, R Geoff; Blauth, Michael

    2015-01-01

    Augmentation of implants with polymethylmethacrylate (PMMA) bone cement in osteoporotic fractures is a promising approach to increase implant purchase. Side effects of PMMA for the metaphyseal bone, particularly for the adjacent subchondral bone plate and joint cartilage, have not yet been studied. The following experimental study investigates whether subchondral PMMA injection compromises the homeostasis of the subchondral bone and/or the joint cartilage.Ten mature sheep were used to simulate subchondral PMMA injection. Follow-ups of 2 (4 animals) and 4 (6 animals) months were chosen to investigate possible cartilage damage and subchondral plate alterations in the knee. Evaluation was completed by means of high-resolution peripheral quantitative computed tomography (HRpQCT) imaging, histopathological osteoarthritis scoring, and determination of glycosaminoglycan content in the joint cartilage. Results were compared with the untreated contralateral knee and statistically analyzed using nonparametric tests.Evaluation of the histological osteoarthritis score revealed no obvious cartilage damage for the treated knee; median histological score after 2 months 0 (range 4), after 4 months 1 (range 5). There was no significant difference when compared with the untreated control site after 2 and 4 months (P = 0.23 and 0.76, respectively). HRpQCT imaging showed no damage to the metaphyseal trabeculae. Glycosaminoglycan measurements of the treated joint cartilage after 4 months revealed no significant difference compared with the untreated cartilage (P = 0.24).The findings of this study support initial clinical observation that PMMA implant augmentation of metaphyseal fractures appears to be a safe procedure for fixation without harming the subchondral bone plate and adjacent joint cartilage.

  3. High-strength braze joints between copper and steel

    NASA Technical Reports Server (NTRS)

    Kuhn, R. F.

    1967-01-01

    High-strength braze joints between copper and steel are produced by plating the faying surface of the copper with a layer of gold. This reduces porosity in the braze area and strengthens the resultant joint.

  4. Subperiosteal Transmission Of Intra-Articular Pressure Between Articulated And Stationary Joints

    PubMed Central

    Pitkin, Mark; Muppavarapu, Raghuveer; Cassidy, Charles; Pitkin, Emil

    2015-01-01

    Hydrostatic pressures can be transmitted between synovial capsules. In each of ten rabbits, we simultaneously measured pressure in two joints, one of which was passively ranged, and the other of which was kept stationary. The intra-articular pressure inside the stationary joint changed every time its companion joint was ranged. But the pressure in the stationary joint did not change when the periosteum was transected above the ranged joint. This phenomenon was observed in all four animals that served as their own controls. The study suggests that the intra-articular pressure was transmitted through the space between the periosteum and the bone surface. Alternative explanations, like measurements of venous blood pressure, did not show correlation with hydrostatic pressure changes in the joints. The Floating Skeleton concept suggests a biomechanical rationale for this newly observed phenomenon: that there exists a subperiosteal hydrostatic connection of synovial joints, and that this “net” distributes excess pressures among joints through the periosteal sheath to sustain the integrity of the joint contacting surfaces over a lifetime. PMID:25632015

  5. Joint optimization of a partially coherent Gaussian beam for free-space optical communication over turbulent channels with pointing errors.

    PubMed

    Lee, It Ee; Ghassemlooy, Zabih; Ng, Wai Pang; Khalighi, Mohammad-Ali

    2013-02-01

    Joint beam width and spatial coherence length optimization is proposed to maximize the average capacity in partially coherent free-space optical links, under the combined effects of atmospheric turbulence and pointing errors. An optimization metric is introduced to enable feasible translation of the joint optimal transmitter beam parameters into an analogous level of divergence of the received optical beam. Results show that near-ideal average capacity is best achieved through the introduction of a larger receiver aperture and the joint optimization technique.

  6. Joint hypermobility leading to osteoarthrosis and chondrocalcinosis.

    PubMed

    Bird, H A; Tribe, C R; Bacon, P A

    1978-06-01

    We have reviewed 21 adults referred to rheumatology clinic and considered to have generalised joint hypermobility by the criteria of Carter and Wilkinson (1964), modified by Beighton et al. (1973). They fell into two categories. 5 patients had a raised plasma viscosity (PV) and in each case a definite pathology was found to account for this, superimposed on hypermobile joints. The remaining 16 had a normal PV and this group was thought to represent the late natural history of hypermobility. 5 of these (aged 32 to 54 years) had no evidence of osteoarthrosis but the remaining 11 (aged 34 to 80 years) had widespread radiological osteoarthrosis. Synovial histology was obtained at arthroscopy in 6 of these patients and 4 (aged 60 to 75) had chondrocalcinosis. This previously undescribed finding may be the end result of hypermobile joints. Hypermobile patients with joint deformity (lax connective tissue), widespread synovial thickening (traumatic), and hot joint effusions (chondrocalcinosis) may mimic rheumatoid arthritis. They must be distinguished from patients who develop rheumatoid arthritis in hypermobile joints.

  7. Joint hypermobility leading to osteoarthrosis and chondrocalcinosis.

    PubMed Central

    Bird, H A; Tribe, C R; Bacon, P A

    1978-01-01

    We have reviewed 21 adults referred to rheumatology clinic and considered to have generalised joint hypermobility by the criteria of Carter and Wilkinson (1964), modified by Beighton et al. (1973). They fell into two categories. 5 patients had a raised plasma viscosity (PV) and in each case a definite pathology was found to account for this, superimposed on hypermobile joints. The remaining 16 had a normal PV and this group was thought to represent the late natural history of hypermobility. 5 of these (aged 32 to 54 years) had no evidence of osteoarthrosis but the remaining 11 (aged 34 to 80 years) had widespread radiological osteoarthrosis. Synovial histology was obtained at arthroscopy in 6 of these patients and 4 (aged 60 to 75) had chondrocalcinosis. This previously undescribed finding may be the end result of hypermobile joints. Hypermobile patients with joint deformity (lax connective tissue), widespread synovial thickening (traumatic), and hot joint effusions (chondrocalcinosis) may mimic rheumatoid arthritis. They must be distinguished from patients who develop rheumatoid arthritis in hypermobile joints. Images PMID:686857

  8. Ball-and-Socket Joint Can Be Disassembled

    NASA Technical Reports Server (NTRS)

    Totah, R. S.

    1982-01-01

    Ball-and-socket joint originally developed for construction of large platforms in zero g could be used in such Earth-based temporary structures as scaffolding, camping equipment, tent posts, trade shows and displays. New joint consists of a socket mounted on central hub or union and ball-ended bolt or fitting mounted at end of a column or any structural member. Unit is self-contained, requires no loose hardware and is engaged or disengaged without tools manually, or remotely by a manipulator.

  9. Immediate effects of bilateral manipulation of talocrural joints on standing stability in healthy subjects.

    PubMed

    Alburquerque-Sendín, Francisco; Fernández-de-las-Peñas, César; Santos-del-Rey, Miguel; Martín-Vallejo, Francisco Javier

    2009-02-01

    The purpose of this study was to investigate the immediate effects of bilateral talocrural joint manipulation on standing stability in healthy subjects. Sixty-two healthy subjects, 16 males and 46 females, aged from 18 to 32 years old (mean: 21+/-3 years old) participated in the study. Subjects were randomly divided into two groups: an intervention group (n=32), who received manipulation of bilateral talocrural joints and a control group (n=30) which did not receive any intervention. Baropodometric and stabilometric evaluations were assessed pre- and 5 min post-intervention by an assessor blinded to the treatment allocation. Intra-group and inter-group comparisons were analysed using appropriate parametric tests. The results indicated that changes on the X coordinate range, length of motion, and mean speed approximated to statistical significance (P=0.06), and changes on the Y coordinate range reached statistical significance (P=0.02). Average X and Y motions, and anterior-posterior or lateral velocities did not show significant differences. Our results showed that bilateral thrust manipulation of the talocrural joint did not modify standing stability, that is, the behavioural pattern of the projection of the centre of pressure, in healthy subjects.

  10. [Influence of Restricting the Ankle Joint Complex Motions on Gait Stability of Human Body].

    PubMed

    Li, Yang; Zhang, Junxia; Su, Hailong; Wang, Xinting; Zhang, Yan

    2016-10-01

    The purpose of this study is to determine how restricting inversion-eversion and pronation-supination motions of the ankle joint complex influences the stability of human gait.The experiment was carried out on a slippery level ground walkway.Spatiotemporal gait parameter,kinematics and kinetics data as well as utilized coefficient of friction(UCOF)were compared between two conditions,i.e.with restriction of the ankle joint complex inversion-eversion and pronation-supination motions(FIXED)and without restriction(FREE).The results showed that FIXED could lead to a significant increase in velocity and stride length and an obvious decrease in double support time.Furthermore,FIXED might affect the motion angle range of knee joint and ankle joint in the sagittal plane.In FIXED condition,UCOF was significantly increased,which could lead to an increase of slip probability and a decrease of gait stability.Hence,in the design of a walker,bipedal robot or prosthetic,the structure design which is used to achieve the ankle joint complex inversion-eversion and pronation-supination motions should be implemented.

  11. [The development of research in tribology of artificial joints].

    PubMed

    Dai, Zhendong; Gong, Juanqing

    2006-06-01

    Aseptic loosening of the prosthesis is a major form for the failure of artificial joints, which results in the conglomeration of wear particles at the bone-implant interface. This paper briefly reviews the recent development of tribology of artificial joints preserving good lubrication, enhancing the wear resistance of materials for the joints, reducing the generation of sensitive-size particles and depressing the debris-tissue reactions. Suggestion for improvement in the design of artificial joints is presented.

  12. Market for ethanol feed joint products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertzmark, D.; Gould, B.

    1979-10-01

    This report presents results of econometric estimations and mathematical simulations of markets for joint feed products of motor ethanol. The major issues considered are the nature of current market price relationships, effects on prices, including feed substitutes prices, and effects of demands for increased use of distillers' grains and gluten meal. The econometric section shows that soybean meal was by far the dominant force in the pricing of the two products. However, neither one could be adequately explained without the inclusion of corn in the estimating equations. Later research shows that this was due to the importance of both feedsmore » for metabolizable energy as well as for protein in livestock diets. Current ration formulations would require some discounting of the value of the protein content of the two feeds. Careful siting of the ethanol facilities, and flexible design of the plants so that a maximum number of products may be extracted from the feedstock, seem necessary. Finally, the analysis indicates that substitution in animal diets of these joint products for the corn or milo used originally requires that additional energy be supplied to the animal by some type of forage crop. This implies that additional land may be required for energy production, for such marginal crops as hay and alfalfa, rather than for row crops.« less

  13. A preliminary study on effects of increment of loads to lower extremity joints during kettlebell swing activity

    NASA Astrophysics Data System (ADS)

    Zin, Muhammad Athif Mat; Rambely, Azmin Sham; Ariff, Noratiqah Mohd

    2018-04-01

    The purpose of the study was to determine the effects of increment of loads to lower extremity joints during the two-hand kettlebell swing (KS) activity with loads of 4 kg, 6 kg and 8 kg. Three male adults participated in this study. Subjects were required to perform a two-hand KS with three different loads which were 4 kg, 6 kg and 8 kg. A Vicon Nexus system (v1.5.2) with three infrared cameras adjusted with 100 Hz speed were used to capture KS motion to produce kinematics data for lower extremity joints which were ankle, knee and hip joints. The results showed that mean maximum flexion angle (MFA) of ankle, knee and hip joints decreased as load increased. Mean MFA of knee joint was the highest while mean MFA of ankle joint was the smallest recorded. Mean MFA of ipsilateral leg was higher than that of contralateral leg for a right-dominant subject.

  14. Evaluation of scattered light distributions of cw-transillumination for functional diagnostic of rheumatic disorders in interphalangeal joints

    NASA Astrophysics Data System (ADS)

    Prapavat, Viravuth; Schuetz, Rijk; Runge, Wolfram; Beuthan, Juergen; Mueller, Gerhard J.

    1995-12-01

    This paper presents in-vitro-studies using the scattered intensity distribution obtained by cw- transillumination to examine the condition of rheumatic disorders of interphalangeal joints. Inflammation of joints, due to rheumatic diseases, leads to changes in the synovial membrane, synovia composition and content, and anatomic geometrical variations. Measurements have shown that these rheumatic induced inflammation processes result in a variation in optical properties of joint systems. With a scanning system the interphalangeal joint is transilluminated with diode lasers (670 nm, 905 nm) perpendicular to the joint cavity. The detection of the entire distribution of the transmitted radiation intensity was performed with a CCD camera. As a function of the structure and optical properties of the transilluminated volume we achieved distributions of scattered radiation which show characteristic variations in intensity and shape. Using signal and image processing procedures we evaluated the measured scattered distributions regarding their information weight, shape and scale features. Mathematical methods were used to find classification criteria to determine variations of the joint condition.

  15. Improved decryption quality and security of a joint transform correlator-based encryption system

    NASA Astrophysics Data System (ADS)

    Vilardy, Juan M.; Millán, María S.; Pérez-Cabré, Elisabet

    2013-02-01

    Some image encryption systems based on modified double random phase encoding and joint transform correlator architecture produce low quality decrypted images and are vulnerable to a variety of attacks. In this work, we analyse the algorithm of some reported methods that optically implement the double random phase encryption in a joint transform correlator. We show that it is possible to significantly improve the quality of the decrypted image by introducing a simple nonlinear operation in the encrypted function that contains the joint power spectrum. This nonlinearity also makes the system more resistant to chosen-plaintext attacks. We additionally explore the system resistance against this type of attack when a variety of probability density functions are used to generate the two random phase masks of the encryption-decryption process. Numerical results are presented and discussed.

  16. Management of acromioclavicular joint injuries.

    PubMed

    Li, Xinning; Ma, Richard; Bedi, Asheesh; Dines, David M; Altchek, David W; Dines, Joshua S

    2014-01-01

    Acromioclavicular joint injuries are among the most common shoulder girdle injuries in athletes and most commonly result from a direct force to the acromion with the arm in an adducted position. Acromioclavicular joint injuries often present with associated injuries to the glenohumeral joint, including an increased incidence of superior labrum anterior posterior (SLAP) tears that may warrant further evaluation and treatment. Anteroposterior stability of the acromioclavicular joint is conferred by the capsule and acromioclavicular ligaments, of which the posterior and superior ligaments are the strongest. Superior-inferior stability is maintained by the coracoclavicular (conoid and trapezoid) ligaments. Type-I or type-II acromioclavicular joint injuries have been treated with sling immobilization, early shoulder motion, and physical therapy, with favorable outcomes. Return to activity can occur when normal shoulder motion and strength are obtained and the shoulder is asymptomatic as compared with the contralateral normal extremity. The management of type-III injuries remains controversial and is individualized. While a return to the previous level of functional activity with nonsurgical treatment has been documented in a number of case series, surgical reduction and coracoclavicular ligament reconstruction has been associated with a favorable outcome and can be considered in patients who place high functional demands on their shoulders or in athletes who participate in overhead sports. Surgical management is indicated for high-grade (≥type IV) acromioclavicular joint injuries to achieve anatomic reduction of the acromioclavicular joint, reconstruction of the coracoclavicular ligaments, and repair of the deltotrapezial fascia. Outcomes after surgical reconstruction of the coracoclavicular ligaments have been satisfactory with regard to achieving pain relief and return to functional activities, but further improvements in the biomechanical strength of these

  17. 2D joint inversion of dc and scalar audio-magnetotelluric data in the evaluation of low enthalpy geothermal fields

    NASA Astrophysics Data System (ADS)

    Monteiro Santos, Fernando A.; Afonso, António R. Andrade; Dupis, André

    2007-03-01

    Audio-magnetotelluric (AMT) and resistivity (dc) surveys are often used in environmental, hydrological and geothermal evaluation. The separate interpretation of those geophysical data sets assuming two-dimensional models frequently produces ambiguous results. The joint inversion of AMT and dc data is advocated by several authors as an efficient method for reducing the ambiguity inherent to each of those methods. This paper presents results obtained from the two-dimensional joint inversion of dipole-dipole and scalar AMT data acquired in a low enthalpy geothermal field situated in a graben. The joint inverted models show a better definition of shallow and deep structures. The results show that the extension of the benefits using joint inversion depends on the number and spacing of the AMT sites. The models obtained from experimental data display a low resistivity zone (<20 Ω m) in the central part of the graben that was correlated with the geothermal reservoir. The resistivity distribution models were used to estimate the distribution of the porosity in the geothermal reservoir applying two different approaches and considering the clay minerals effect. The results suggest that the maximum porosity of the reservoir is not uniform and might be in the range of 12% to 24%.

  18. Efficient finite element modelling for the investigation of the dynamic behaviour of a structure with bolted joints

    NASA Astrophysics Data System (ADS)

    Omar, R.; Rani, M. N. Abdul; Yunus, M. A.; Mirza, W. I. I. Wan Iskandar; Zin, M. S. Mohd

    2018-04-01

    A simple structure with bolted joints consists of the structural components, bolts and nuts. There are several methods to model the structures with bolted joints, however there is no reliable, efficient and economic modelling methods that can accurately predict its dynamics behaviour. Explained in this paper is an investigation that was conducted to obtain an appropriate modelling method for bolted joints. This was carried out by evaluating four different finite element (FE) models of the assembled plates and bolts namely the solid plates-bolts model, plates without bolt model, hybrid plates-bolts model and simplified plates-bolts model. FE modal analysis was conducted for all four initial FE models of the bolted joints. Results of the FE modal analysis were compared with the experimental modal analysis (EMA) results. EMA was performed to extract the natural frequencies and mode shapes of the test physical structure with bolted joints. Evaluation was made by comparing the number of nodes, number of elements, elapsed computer processing unit (CPU) time, and the total percentage of errors of each initial FE model when compared with EMA result. The evaluation showed that the simplified plates-bolts model could most accurately predict the dynamic behaviour of the structure with bolted joints. This study proved that the reliable, efficient and economic modelling of bolted joints, mainly the representation of the bolting, has played a crucial element in ensuring the accuracy of the dynamic behaviour prediction.

  19. Novel joint cupping clinical maneuver for ultrasonographic detection of knee joint effusions.

    PubMed

    Uryasev, Oleg; Joseph, Oliver C; McNamara, John P; Dallas, Apostolos P

    2013-11-01

    Knee effusions occur due to traumatic and atraumatic causes. Clinical diagnosis currently relies on several provocative techniques to demonstrate knee joint effusions. Portable bedside ultrasonography (US) is becoming an adjunct to diagnosis of effusions. We hypothesized that a US approach with a clinical joint cupping maneuver increases sensitivity in identifying effusions as compared to US alone. Using unembalmed cadaver knees, we injected fluid to create effusions up to 10 mL. Each effusion volume was measured in a lateral transverse location with respect to the patella. For each effusion we applied a joint cupping maneuver from an inferior approach, and re-measured the effusion. With increased volume of saline infusion, the mean depth of effusion on ultrasound imaging increased as well. Using a 2-mm cutoff, we visualized an effusion without the joint cupping maneuver at 2.5 mL and with the joint cupping technique at 1 mL. Mean effusion diameter increased on average 0.26 cm for the joint cupping maneuver as compared to without the maneuver. The effusion depth was statistically different at 2.5 and 7.5 mL (P < .05). Utilizing a joint cupping technique in combination with US is a valuable tool in assessing knee effusions, especially those of subclinical levels. Effusion measurements are complicated by uneven distribution of effusion fluid. A clinical joint cupping maneuver concentrates the fluid in one recess of the joint, increasing the likelihood of fluid detection using US. © 2013 Elsevier Inc. All rights reserved.

  20. Joint JSC/GSFC two-TDRS navigation certification results for STS-29, STS-30, and STS-32

    NASA Technical Reports Server (NTRS)

    Schmidt, Thomas G.; Brown, Edward T.; Murdock, Valerie E.; Cappellari, James O., Jr.; Smith, Evan A.; Schmitt, Mark W.; Omalley, James W.; Lowes, Flora B.; Joyce, James B.

    1990-01-01

    The procedures used and the results obtained in the joint Johnson Space Center (JSC)/Goddard Space Flight Center (GSFC) navigation certification of the two-Tracking and Data Relay Satellite (TDRS) S-band tracking configuration for support of low- to medium-inclination (28.5 to 62 degrees) Shuttle missions (STS-29 and STS-30) and Shuttle rendezvous missions (STS-32) are described. The objective of this certification effort was to certify the two-TDRS configuration for nominal Space Transportation System (STS) on-orbit navigation support, thereby making it possible to significantly reduce the ground tracking support requirements for routine STS on-orbit navigation. JSC had the primary responsibility for certification of the two-TDRS configuration for STS support, and GSFC supported the effort by performing Ground Network (GN) and Space Network (SN) tracking data evaluation, parallel orbit solutions, and solution comparisons. In the certification process, two types of orbit determination solutions were generated by JSC and by GSFC for each tracking arc evaluated, one type using TDRS-East and TDRS-West tracking data combined with ground tracking data (the reference solutions) and one type using only TDRS-East and TDRS-West tracking data. The two types of solutions were then compared to determine the maximum position differences over the solution arcs and whether these differences satisfied the navigation certification criteria. The certification criteria were a function of the type of Shuttle activity in the tracking arc, i.e., quiet, moderate, or active. Quiet periods included no attitude maneuvers or ventings; moderate periods included one or two maneuvers or ventings; and active periods included more than two maneuvers or ventings. The results of the individual JSC and GSFC certification analyses for the STS-29, STS-30, and STS-32 missions and the joint JSC/GSFC conclusions regarding certification of the two-TDRS S-band configuration for STS support are presented.

  1. Design of a knee joint mechanism that adapts to individual physiology.

    PubMed

    Jiun-Yih Kuan; Pasch, Kenneth A; Herr, Hugh M

    2014-01-01

    This paper describes the design of a new knee joint mechanism, called the Adaptive Coupling Joint (ACJ). The new mechanism has an adaptive trajectory of the center of rotations (COR) that automatically matches those of the attached biological joint. The detailed design is presented as well as characterization results of the ACJ. Conventional exoskeleton and assistive devices usually consider limb joints as a one to three degrees of freedom (DOFs) joint synthesized by multiple one-DOF hinge joints in a single plane. However, the biological joints are complex and usually rotate with respect to a changing COR. As a result, the mismatch between limb joint motion and mechanical interface motion can lead to forces that cause undesired ligament and muscle length changes and internal mechanical changes. These undesired changes contribute to discomfort, as well as to the slippage and sluggish interaction between humans and devices. It is shown that the ACJ can transmit planetary torques from either active or passive devices to the limbs without altering the normal biological joint motion.

  2. Anaerobic prosthetic joint infection.

    PubMed

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  3. Joint mobilization acutely improves landing kinematics in chronic ankle instability.

    PubMed

    Delahunt, Eamonn; Cusack, Kim; Wilson, Laura; Doherty, Cailbhe

    2013-03-01

    The objective of this study is to examine the acute effect of ankle joint mobilizations akin to those performed in everyday clinical practice on sagittal plane ankle joint kinematics during a single-leg drop landing in participants with chronic ankle instability (CAI). Fifteen participants with self-reported CAI (defined as <24 on the Cumberland Ankle Instability Tool) performed three single-leg drop landings under two different conditions: 1) premobilization and, 2) immediately, postmobilization. The mobilizations performed included Mulligan talocrural joint dorsiflexion mobilization with movement, Mulligan inferior tibiofibular joint mobilization, and Maitland anteroposterior talocrural joint mobilization. Three CODA cx1 units (Charnwood Dynamics Ltd., Leicestershire, UK) were used to provide information on ankle joint sagittal plane angular displacement. The dependent variable under investigation was the angle of ankle joint plantarflexion at the point of initial contact during the drop landing. There was a statistically significant acute decrease in the angle of ankle joint plantarflexion from premobilization (34.89° ± 4.18°) to postmobilization (31.90° ± 5.89°), t(14) = 2.62, P < 0.05 (two-tailed). The mean decrease in the angle of ankle joint plantarflexion as a result of the ankle joint mobilization was 2.98° with a 95% confidence interval ranging from 0.54 to 5.43. The eta squared statistic (0.32) indicated a large effect size. These results indicate that mobilization acted to acutely reduce the angle of ankle joint plantarflexion at initial contact during a single-leg drop landing. Mobilization applied to participants with CAI has a mechanical effect on the ankle joint, thus facilitating a more favorable positioning of the ankle joint when landing from a jump.

  4. Movement coordination patterns between the foot joints during walking.

    PubMed

    Arnold, John B; Caravaggi, Paolo; Fraysse, François; Thewlis, Dominic; Leardini, Alberto

    2017-01-01

    In 3D gait analysis, kinematics of the foot joints are usually reported via isolated time histories of joint rotations and no information is provided on the relationship between rotations at different joints. The aim of this study was to identify movement coordination patterns in the foot during walking by expanding an existing vector coding technique according to an established multi-segment foot and ankle model. A graphical representation is also described to summarise the coordination patterns of joint rotations across multiple patients. Three-dimensional multi-segment foot kinematics were recorded in 13 adults during walking. A modified vector coding technique was used to identify coordination patterns between foot joints involving calcaneus, midfoot, metatarsus and hallux segments. According to the type and direction of joints rotations, these were classified as in-phase (same direction), anti-phase (opposite directions), proximal or distal joint dominant. In early stance, 51 to 75% of walking trials showed proximal-phase coordination between foot joints comprising the calcaneus, midfoot and metatarsus. In-phase coordination was more prominent in late stance, reflecting synergy in the simultaneous inversion occurring at multiple foot joints. Conversely, a distal-phase coordination pattern was identified for sagittal plane motion of the ankle relative to the midtarsal joint, highlighting the critical role of arch shortening to locomotor function in push-off. This study has identified coordination patterns between movement of the calcaneus, midfoot, metatarsus and hallux by expanding an existing vector cording technique for assessing and classifying coordination patterns of foot joints rotations during walking. This approach provides a different perspective in the analysis of multi-segment foot kinematics, and may be used for the objective quantification of the alterations in foot joint coordination patterns due to lower limb pathologies or following injuries.

  5. DETAIL VIEW ON THE MAIN ASSEMBLY LEVEL OF ELEVATOR SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL VIEW ON THE MAIN ASSEMBLY LEVEL OF ELEVATOR SHOWING THE DOUBLED COLUMN FOR THE BUILDING EXPANSION JOINT AT COLUMN LINE AA-18. - Offutt Air Force Base, Glenn L. Martin-Nebraska Bomber Plant, Building D, Peacekeeper Drive, Bellevue, Sarpy County, NE

  6. Postoperative Therapy for Chronic Thumb Carpometacarpal (CMC) Joint Dislocation.

    PubMed

    Wollstein, Ronit; Michael, Dafna; Harel, Hani

    2016-01-01

    Surgical arthroplasty of thumb carpometacarpal (CMC) joint osteoarthritis is commonly performed. Postoperative therapeutic protocols aim to improve range of motion and function of the revised thumb. We describe a case in which the thumb CMC joint had been chronically dislocated before surgery, with shortening of the soft-tissue dynamic and static stabilizers of the joint. The postoperative protocol addressed the soft tissues using splinting and exercises aimed at lengthening and strengthening these structures, with good results. It may be beneficial to evaluate soft-tissue tension and the pattern of thumb use after surgery for thumb CMC joint osteoarthritis to improve postoperative functional results. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  7. Joint working. Local differences.

    PubMed

    Hudson, B

    1997-09-18

    The interface between social care and primary healthcare remains underdeveloped. Where joint working is effective, it is the result of co-operation, trust and mutual respect. Successful local networks take account of professional autonomy.

  8. Structure and Mechanical Properties of Friction Stir Weld Joints of Magnesium Alloy AZ31

    NASA Astrophysics Data System (ADS)

    Nagasawa, T.; Otsuka, M.; Yokota, T.; Ueki, T.

    The applicability of friction stir welding to hot rolled sheet of commercial magnesium alloy AZ31 plates has been investigated. Friction stir weld joint showed mechanical strength comparable to that of base material, though the ductility remained at one half of that of the latter. The results are consistent with the microstructure which is characterized by a fine grained bond layer bounded by-intermediate grained base metals. It is found that both anodizing treatment and insertion of aluminum foil between batting faces do not degrade the joint properties at all. The results suggest that friction stir welding can be potentially applied to magnesium alloy.

  9. Design, Static Analysis And Fabrication Of Composite Joints

    NASA Astrophysics Data System (ADS)

    Mathiselvan, G.; Gobinath, R.; Yuvaraja, S.; Raja, T.

    2017-05-01

    The Bonded joints will be having one of the important issues in the composite technology is the repairing of aging in aircraft applications. In these applications and also for joining various composite material parts together, the composite materials fastened together either using adhesives or mechanical fasteners. In this paper, we have carried out design, static analysis of 3-D models and fabrication of the composite joints (bonded, riveted and hybrid). The 3-D model of the composite structure will be fabricated by using the materials such as epoxy resin, glass fibre material and aluminium rivet for preparing the joints. The static analysis was carried out with different joint by using ANSYS software. After fabrication, parametric study was also conducted to compare the performance of the hybrid joint with varying adherent width, adhesive thickness and overlap length. Different joint and its materials tensile test result have compared.

  10. Self-perceived weather sensitivity and joint pain in older people with osteoarthritis in six European countries: results from the European Project on OSteoArthritis (EPOSA)

    PubMed Central

    2014-01-01

    Background People with osteoarthritis (OA) frequently report that their joint pain is influenced by weather conditions. This study aimed to examine whether there are differences in perceived joint pain between older people with OA who reported to be weather-sensitive versus those who did not in six European countries with different climates and to identify characteristics of older persons with OA that are most predictive of perceived weather sensitivity. Methods Baseline data from the European Project on OSteoArthritis (EPOSA) were used. ACR classification criteria were used to determine OA. Participants with OA were asked about their perception of weather as influencing their pain. Using a two-week follow-up pain calendar, average self-reported joint pain was assessed (range: 0 (no pain)-10 (greatest pain intensity)). Linear regression analyses, logistic regression analyses and an independent t-test were used. Analyses were adjusted for several confounders. Results The majority of participants with OA (67.2%) perceived the weather as affecting their pain. Weather-sensitive participants reported more pain than non-weather-sensitive participants (M = 4.1, SD = 2.4 versus M = 3.1, SD = 2.4; p < 0.001). After adjusting for several confounding factors, the association between self-perceived weather sensitivity and joint pain remained present (B = 0.37, p = 0.03). Logistic regression analyses revealed that women and more anxious people were more likely to report weather sensitivity. Older people with OA from Southern Europe were more likely to indicate themselves as weather-sensitive persons than those from Northern Europe. Conclusions Weather (in)stability may have a greater impact on joint structures and pain perception in people from Southern Europe. The results emphasize the importance of considering weather sensitivity in daily life of older people with OA and may help to identify weather-sensitive older people with OA. PMID:24597710

  11. MRI-based modeling for radiocarpal joint mechanics: validation criteria and results for four specimen-specific models.

    PubMed

    Fischer, Kenneth J; Johnson, Joshua E; Waller, Alexander J; McIff, Terence E; Toby, E Bruce; Bilgen, Mehmet

    2011-10-01

    The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations

  12. Modeling and analysis of passive dynamic bipedal walking with segmented feet and compliant joints

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Wang, Qi-Ning; Gao, Yue; Xie, Guang-Ming

    2012-10-01

    Passive dynamic walking has been developed as a possible explanation for the efficiency of the human gait. This paper presents a passive dynamic walking model with segmented feet, which makes the bipedal walking gait more close to natural human-like gait. The proposed model extends the simplest walking model with the addition of flat feet and torsional spring based compliance on ankle joints and toe joints, to achieve stable walking on a slope driven by gravity. The push-off phase includes foot rotations around the toe joint and around the toe tip, which shows a great resemblance to human normal walking. This paper investigates the effects of the segmented foot structure on bipedal walking in simulations. The model achieves satisfactory walking results on even or uneven slopes.

  13. Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.

    PubMed

    Hast, Michael W; Piazza, Stephen J

    2013-02-01

    Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.

  14. Analysis and optimization of the active rigidity joint

    NASA Astrophysics Data System (ADS)

    Manzo, Justin; Garcia, Ephrahim

    2009-12-01

    The active rigidity joint is a composite mechanism using shape memory alloy and shape memory polymer to create a passively rigid joint with thermally activated deflection. A new model for the active rigidity joint relaxes constraints of earlier methods and allows for more accurate deflection predictions compared to finite element results. Using an iterative process to determine the strain distribution and deflection, the method demonstrates accurate results for both surface bonded and embedded actuators with and without external loading. Deflection capabilities are explored through simulated annealing heuristic optimization using a variety of cost functions to explore actuator performance. A family of responses presents actuator characteristics in terms of load bearing and deflection capabilities given material and thermal constraints. Optimization greatly expands the available workspace of the active rigidity joint from the initial configuration, demonstrating specific work capabilities comparable to those of muscle tissue.

  15. Modulation of shoulder muscle and joint function using a powered upper-limb exoskeleton.

    PubMed

    Wu, Wen; Fong, Justin; Crocher, Vincent; Lee, Peter V S; Oetomo, Denny; Tan, Ying; Ackland, David C

    2018-04-27

    Robotic-assistive exoskeletons can enable frequent repetitive movements without the presence of a full-time therapist; however, human-machine interaction and the capacity of powered exoskeletons to attenuate shoulder muscle and joint loading is poorly understood. This study aimed to quantify shoulder muscle and joint force during assisted activities of daily living using a powered robotic upper limb exoskeleton (ArmeoPower, Hocoma). Six healthy male subjects performed abduction, flexion, horizontal flexion, reaching and nose touching activities. These tasks were repeated under two conditions: (i) the exoskeleton compensating only for its own weight, and (ii) the exoskeleton providing full upper limb gravity compensation (i.e., weightlessness). Muscle EMG, joint kinematics and joint torques were simultaneously recorded, and shoulder muscle and joint forces calculated using personalized musculoskeletal models of each subject's upper limb. The exoskeleton reduced peak joint torques, muscle forces and joint loading by up to 74.8% (0.113 Nm/kg), 88.8% (5.8%BW) and 68.4% (75.6%BW), respectively, with the degree of load attenuation strongly task dependent. The peak compressive, anterior and superior glenohumeral joint force during assisted nose touching was 36.4% (24.6%BW), 72.4% (13.1%BW) and 85.0% (17.2%BW) lower than that during unassisted nose touching, respectively. The present study showed that upper limb weight compensation using an assistive exoskeleton may increase glenohumeral joint stability, since deltoid muscle force, which is the primary contributor to superior glenohumeral joint shear, is attenuated; however, prominent exoskeleton interaction moments are required to position and control the upper limb in space, even under full gravity compensation conditions. The modeling framework and results may be useful in planning targeted upper limb robotic rehabilitation tasks. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Early, asymptomatic stage of degenerative joint disease in canine hip joints.

    PubMed

    Lust, G; Summers, B A

    1981-11-01

    The early stages of degenerative joint disease were investigated in coxofemoral joints from dogs with a hereditary predisposition to hip dysplasia. Alterations observed included mild nonsuppurative synovitis, increased volume of both synovial fluid and the ligamentum teres, and focal degenerative articular cartilage lesions. On radiologic examination, subluxation of the femoral head was seen, but only in the most severely affected joints. Synovial inflammation with increased synovial fluid and ligament volumes were indicators of early degenerative joint disease in dogs. These changes seemed to coincide with, or perhaps to precede, microscopic evidence for articular cartilage degeneration and occurred before radiologic abnormalities were detected.

  17. Time-lapse joint inversion of geophysical data with automatic joint constraints and dynamic attributes

    NASA Astrophysics Data System (ADS)

    Rittgers, J. B.; Revil, A.; Mooney, M. A.; Karaoulis, M.; Wodajo, L.; Hickey, C. J.

    2016-12-01

    Joint inversion and time-lapse inversion techniques of geophysical data are often implemented in an attempt to improve imaging of complex subsurface structures and dynamic processes by minimizing negative effects of random and uncorrelated spatial and temporal noise in the data. We focus on the structural cross-gradient (SCG) approach (enforcing recovered models to exhibit similar spatial structures) in combination with time-lapse inversion constraints applied to surface-based electrical resistivity and seismic traveltime refraction data. The combination of both techniques is justified by the underlying petrophysical models. We investigate the benefits and trade-offs of SCG and time-lapse constraints. Using a synthetic case study, we show that a combined joint time-lapse inversion approach provides an overall improvement in final recovered models. Additionally, we introduce a new approach to reweighting SCG constraints based on an iteratively updated normalized ratio of model sensitivity distributions at each time-step. We refer to the new technique as the Automatic Joint Constraints (AJC) approach. The relevance of the new joint time-lapse inversion process is demonstrated on the synthetic example. Then, these approaches are applied to real time-lapse monitoring field data collected during a quarter-scale earthen embankment induced-piping failure test. The use of time-lapse joint inversion is justified by the fact that a change of porosity drives concomitant changes in seismic velocities (through its effect on the bulk and shear moduli) and resistivities (through its influence upon the formation factor). Combined with the definition of attributes (i.e. specific characteristics) of the evolving target associated with piping, our approach allows localizing the position of the preferential flow path associated with internal erosion. This is not the case using other approaches.

  18. Effect of Gold on the Microstructural Evolution and Integrity of a Sintered Silver Joint

    NASA Astrophysics Data System (ADS)

    Muralidharan, Govindarajan; Leonard, Donovan N.; Meyer, Harry M.

    2017-07-01

    There is a need for next-generation, high-performance power electronic packages and systems employing wide-bandgap devices to operate at high temperatures in automotive and electric grid applications. Sintered silver joints are currently being evaluated as an alternative to Pb-free solder joints. Of particular interest is the development of joints based on silver paste consisting of nano- or micron-scale particles that can be processed without application of external pressure. The microstructural evolution at the interface of a pressureless-sintered silver joint formed between a SiC die with Ti/Ni/Au metallization and an active metal brazed (AMB) substrate with Ag metallization at 250°C has been evaluated using scanning electron microscopy (SEM), x-ray microanalysis, and x-ray photoelectron spectroscopy (XPS). Results from focused ion beam (FIB) cross-sections show that, during sintering, pores in the sintered region near to the Au layer tend to be narrow and elongated with long axis oriented parallel to the interface. Further densification results in formation of many small, relatively equiaxed pores aligned parallel to the interface, creating a path for easy crack propagation. X-ray microanalysis results confirm interdiffusion between Au and Ag and that a region with poor mechanical strength is formed at the edge of this region of interdiffusion.

  19. Radiological study of the knee joint line position measured from the fibular head and proximal tibial landmarks.

    PubMed

    Havet, Eric; Gabrion, Antoine; Leiber-Wackenheim, Frederic; Vernois, Joël; Olory, Bruno; Mertl, Patrice

    2007-06-01

    Restoring the joint line level is one of the surgical challenges during revision of total knee arthroplasty. The position of the tibial surface is commonly estimated by its distance to the apex of fibular head, but no study evaluating this distance accurately has been published yet. The purpose of this work was to study the distance between the knee joint line and the apex of the fibular head and the proximal tibia, particularly the tibial tuberosity. Variability with clinical data and relations with other local measurements have been evaluated on knee radiographs (an antero-posterior view, a medio-lateral view and an anteroposterior full length view) of 100 subjects (125 knees). Results showed no correlation between the joint line-fibular head apex distance and any clinical data of the patients, or any other performed measurements. Relations between tibial measurements and the sexe or the height of the subjects were noted. Besides, the review of the 25 bilateral cases did not show statistically significant side difference but the descriptive analysis showed too large discrepancies for the joint line-fibular head apex distance to be used as a landmark. We conclude that the fibular head apex cannot be used as a morphologic landmark to determine the knee joint line position. Its interest in clinical and surgical practice must be discussed.

  20. Joint kinematics of surgeons during lumbar pedicle screw placement.

    PubMed

    Park, Jeong-Yoon; Kim, Kyung-Hyun; Kuh, Sung-Uk; Chin, Dong-Kyu; Kim, Keun-Su; Cho, Yong-Eun

    2016-12-01

    A surgical robot for spine surgery has recently been developed. The objective is to assess the joint kinematics of the surgeon during spine surgery. We enrolled 18 spine surgeons, who each performed pedicle screw placement, and used an optoelectronic motion analysis system. Using three-dimensional (3D) motion images, distance changes in five joints and angle changes in six joints were calculated during surgery. Distance fluctuations increased gradually from the proximal to the distal joint. Angle fluctuations were largest at the distal point but did not gradually increase, and the elbow showed the second largest fluctuation. Changes along the X axis were larger than those of the Y and Z axes. The distances gradually increased from proximal portions of the body to the hand. In angle changes, the elbow was most dynamic during pedicle screw placement. The surgeons' whole joints carry out a harmonic role during lumbar pedicle screw placement. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  1. The Influence of Weather Conditions on Joint Pain in Older People with Osteoarthritis: Results from the European Project on OSteoArthritis.

    PubMed

    Timmermans, Erik J; Schaap, Laura A; Herbolsheimer, Florian; Dennison, Elaine M; Maggi, Stefania; Pedersen, Nancy L; Castell, Maria Victoria; Denkinger, Michael D; Edwards, Mark H; Limongi, Federica; Sánchez-Martínez, Mercedes; Siviero, Paola; Queipo, Rocio; Peter, Richard; van der Pas, Suzan; Deeg, Dorly J H

    2015-10-01

    This study examined whether daily weather conditions, 3-day average weather conditions, and changes in weather conditions influence joint pain in older people with osteoarthritis (OA) in 6 European countries. Data from the population-based European Project on OSteoArthritis were used. The American College of Rheumatology classification criteria were used to diagnose OA in older people (65-85 yrs). After the baseline interview, at 6 months, and after the 12-18 months followup interview, joint pain was assessed using 2-week pain calendars. Daily values for temperature, precipitation, atmospheric pressure, relative humidity, and wind speed were obtained from local weather stations. Multilevel regression modelling was used to examine the pain-weather associations, adjusted for several confounders. The study included 810 participants with OA in the knee, hand, and/or hip. After adjustment, there were significant associations of joint pain with daily average humidity (B = 0.004, p < 0.01) and 3-day average humidity (B = 0.004, p = 0.01). A significant interaction effect was found between daily average humidity and temperature on joint pain. The effect of humidity on pain was stronger in relatively cold weather conditions. Changes in weather variables between 2 consecutive days were not significantly associated with reported joint pain. The associations between pain and daily average weather conditions suggest that a causal relationship exist between joint pain and weather variables, but the associations between day-to-day weather changes and pain do not confirm causation. Knowledge about the relationship between joint pain in OA and weather may help individuals with OA, physicians, and therapists to better understand and manage fluctuations in pain.

  2. Audio-based bolt-loosening detection technique of bolt joint

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Zhao, Xuefeng; Su, Wensheng; Xue, Zhigang

    2018-03-01

    Bolt joint, as the commonest coupling structure, is widely used in electro-mechanical system. However, it is the weakest part of the whole system. The increase of preload tension force can raise the reliability and strength of the bolt joint. Therefore, the pretension force is one of the most important factors to ensure the stability of bolt joint. According to the way of generating pretension force, the pretension force can be monitored by bolt torque, degrees and elongation. The existing bolt-loosening monitoring methods all require expensive equipment, which greatly restricts the practicality of the bolt-loosening monitoring. In this paper, a new method of bolt-loosening detection technique based on audio is proposed. The sound that bolt is hit by a hammer is recorded on the Smartphone, and the collected audio signal is classified and identified by support vector machine algorithm. First, a verification test was designed and the results show that this new method can identify the damage of bolt looseness accurately. Second, a variety of bolt-loosening was identified. The results indicate that this method has a high accuracy in multiclass classification of the bolt looseness. This bolt-loosening detection technique based on audio not only can reduce the requirements of technical and professional experience, but also make bolt-loosening monitoring simpler and easier.

  3. Arthrofibrosis involving the middle facet of the talocalcaneal joint in children and adolescents.

    PubMed

    El Rassi, George; Riddle, Eric C; Kumar, S Jay

    2005-10-01

    Pain over the anterolateral aspect of the ankle in a patient with a history of repeated ankle sprains and with restricted subtalar movement may be associated with a tarsal coalition. Nineteen patients presented with such a history, but conventional imaging did not reveal a cartilaginous or osseous coalition. Since symptoms persisted despite nonoperative treatment, the middle facet was explored surgically. The purpose of this study was to discuss the operative findings and to report the results of treatment. Nineteen patients (twenty-three feet) with pain over the anterolateral aspect of the ankle or a history of repeated ankle sprains had restricted subtalar joint motion and inconclusive findings on diagnostic imaging, except for bone-scanning. Their ages ranged from 9.1 to 18.5 years. The middle facet of the subtalar joint was explored surgically through a 3 to 4-cm-long incision centered over the sustentaculum tali. The results at a mean of 5.8 years were classified as good, fair, or poor on the basis of pain, talocalcaneal joint motion, and shoe wear. Routine radiographs, computed tomography, and magnetic resonance imaging revealed no major abnormality, whereas technetium-99m bone scintigraphy consistently showed slightly increased isotope uptake in the middle facet. Surgical removal of a hypervascular and thickened capsule and synovium in the area of the middle facet of the subtalar joint decreased pain and improved subtalar motion. The final result was good in seventeen patients (twenty feet) and fair in two patients (three feet). There were no poor results. A diagnosis of inflammatory arthrofibrosis should be considered when a patient with a painful rigid flatfoot has normal findings on radiographs and hematological studies but increased isotope uptake in the middle facet of the talocalcaneal joint on bone scintigraphy. Excision of the hypervascular capsule and synovium from this area can result in resolution of the symptoms. Therapeutic Level IV.

  4. Microstructural Evolution of HSLA ISO 3183 X80M (API 5L X80) Friction Stir Welded Joints

    NASA Astrophysics Data System (ADS)

    Hermenegildo, Tahiana F. C.; Santos, Tiago F. A.; Torres, Edwar A.; Afonso, Conrado R. M.; Ramirez, Antonio J.

    2018-03-01

    Evaluation was made of friction stir welded joints, identifying conditions that resulted in satisfactory welded joints free from defects and with microstructural characteristics that provided good mechanical properties. Microstructural characterization and cooling curve analysis of the joints with lower and higher heat inputs evidenced deformation below and above the non-recrystallization temperature (Tnr) and dynamic recrystallization during microstructural evolution. Microscopy analyses showed acicular ferrite, bainitic ferrite, and coalesced bainite microstructures in the stir zone of the cold weld (lower heat input), while the stir zone of the hot weld (higher heat input) contained bainitic ferrite, acicular ferrite, coalesced bainite, martensite, and dispersed carbides. Granular bainite and dispersed carbides were observed in all the heat affected zones. Analysis of the microstructural transformations, together with the thermal history of the joints, showed that the variable that had the greatest influence on the morphology of the bainite (granular bainite/bainitic ferrite) was the deformation temperature.

  5. The influence of joint parameters on normal fault evolution and geometry: a parameter study using analogue modeling

    NASA Astrophysics Data System (ADS)

    Kettermann, Michael; von Hagke, Christoph; Urai, Janos L.

    2017-04-01

    Dilatant faults often form in rocks containing pre-existing joints, but the effects of joints on fault segment linkage and fracture connectivity is not well understood. Studying evolution of dilatancy and influence of fractures on fault development provides insights into geometry of fault zones in brittle rocks and will eventually allow for predicting their subsurface appearance. In an earlier study we recognized the effect of different angles between strike direction of vertical joints and a basement fault on the geometry of a developing fault zone. We now systematically extend the results by varying geometric joint parameters such as joint spacing and vertical extent of the joints and measuring fracture density and connectivity. A reproducibility study shows a small error-range for the measurements, allowing for a confident use of the experimental setup. Analogue models were carried out in a manually driven deformation box (30x28x20 cm) with a 60° dipping pre-defined basement fault and 4.5 cm of displacement. To produce open joints prior to faulting, sheets of paper were mounted in the box to a depth of 5 cm at a spacing of 2.5 cm. We varied the vertical extent of the joints from 5 to 50 mm. Powder was then sieved into the box, embedding the paper almost entirely (column height of 19 cm), and the paper was removed. During deformation we captured structural information by time-lapse photography that allows particle imaging velocimetry analyses (PIV) to detect localized deformation at every increment of displacement. Post-mortem photogrammetry preserves the final 3-dimensional structure of the fault zone. A counterintuitive result is that joint depth is of only minor importance for the evolution of the fault zone. Even very shallow joints form weak areas at which the fault starts to form and propagate. More important is joint spacing. Very large joint spacing leads to faults and secondary fractures that form subparallel to the basement fault. In contrast, small

  6. Respiratory pattern changes during costovertebral joint movement.

    PubMed

    Shannon, R

    1980-05-01

    Experiments were conducted to determine if costovertebral joint manipulation (CVJM) could influence the respiratory pattern. Phrenic efferent activity (PA) was monitored in dogs that were anesthetized with Dial-urethane, vagotomized, paralyzed, and artificially ventilated. Ribs 6-10 (bilaterally) were cut and separated from ribs 5-11. Branches of thoracic nerves 5-11 were cut, leaving only the joint nerve supply intact. Manual joint movement in an inspiratory or expiratory direction had an inhibitory effect on PA. Sustained displacement of the ribs could inhibit PA for a duration equal to numerous respiratory cycles. CVJM in synchrony with PA resulted in an increased respiratory rate. The inspiratory inhibitory effect of joint receptor stimulation was elicited with manual chest compression in vagotomized spontaneously breathing dogs, but not with artificial lung inflation or deflation. It is concluded that the effect of CVJM on the respiratory pattern is due to stimulation of joint mechanoreceptors, and that they exert their influence in part via the medullary-pontine rhythm generator.

  7. The International Space Station Solar Alpha Rotary Joint Anomaly Investigation

    NASA Technical Reports Server (NTRS)

    Harik, Elliot P.; McFatter, Justin; Sweeney, Daniel J.; Enriquez, Carlos F.; Taylor, Deneen M.; McCann, David S.

    2010-01-01

    The Solar Alpha Rotary Joint (SARJ) is a single-axis pointing mechanism used to orient the solar power generating arrays relative to the sun for the International Space Station (ISS). Approximately 83 days after its on-orbit installation, one of the two SARJ mechanisms aboard the ISS began to exhibit high drive motor current draw. Increased structural vibrations near the joint were also observed. Subsequent inspections via Extravehicular Activity (EVA) discovered that the nitrided case-hardened steel bearing race on the outboard side of the joint had extensive damage to one of its three rolling surfaces. A farreaching investigation of the anomaly was undertaken. The investigation included metallurgical inspections, coupon tests, traction kinematics tests, detailed bearing measurements, and thermal and structural analyses. The results of the investigation showed that the anomaly had most probably been caused by high bearing edge stresses that resulted from inadequate lubrication of the rolling contact. The profile of the roller bearings and the metallurgical properties of the race ring were also found to be significant contributing factors. To mitigate the impact of the damage, astronauts cleaned and lubricated the race ring surface with grease. This corrective action led to significantly improved performance of the mechanism both in terms of drive motor current and induced structural vibration.

  8. The International Space Station Solar Alpha Rotary Joint Anomaly Investigation

    NASA Technical Reports Server (NTRS)

    Harik, Elliot P.; McFatter, Justin; Sweeney, Daniel J.; Enriquez, Carlos F.; Taylor, Deneen M.; McCann, David S.

    2010-01-01

    The Solar Alpha Rotary Joint (SARJ) is a single-axis pointing mechanism used to orient the solar power generating arrays relative to the sun for the International Space Station (ISS). Approximately 83 days after its on-orbit installation, one of the two SARJ mechanisms aboard the ISS began to exhibit high drive motor current draw. Increased structural vibrations near the joint were also observed. Subsequent inspections via Extravehicular Activity (EVA) discovered that the nitrided case hardened steel bearing race on the outboard side of the joint had extensive damage to one of its three rolling surfaces. A far-reaching investigation of the anomaly was undertaken. The investigation included metallurgical inspections, coupon tests, traction kinematics tests, detailed bearing measurements, and thermal and structural analyses. The results of the investigation showed that anomaly had most probably been caused by high bearing edge stresses that resulted from inadequate lubrication of the rolling contact. The profile of the roller bearings and the metallurgical properties of the race ring were also found to be significant contributing factors. To mitigate the impact of the damage astronauts cleaned and lubricated the race ring surface with grease. This corrective action led to significantly improved performance of the mechanism both in terms of drive motor current and induced structural vibration.

  9. Reusable Solid Rocket Motor Nozzle Joint-4 Thermal Analysis

    NASA Technical Reports Server (NTRS)

    Clayton, J. Louie

    2001-01-01

    This study provides for development and test verification of a thermal model used for prediction of joint heating environments, structural temperatures and seal erosions in the Space Shuttle Reusable Solid Rocket Motor (RSRM) Nozzle Joint-4. The heating environments are a result of rapid pressurization of the joint free volume assuming a leak path has occurred in the filler material used for assembly gap close out. Combustion gases flow along the leak path from nozzle environment to joint O-ring gland resulting in local heating to the metal housing and erosion of seal materials. Analysis of this condition was based on usage of the NASA Joint Pressurization Routine (JPR) for environment determination and the Systems Improved Numerical Differencing Analyzer (SINDA) for structural temperature prediction. Model generated temperatures, pressures and seal erosions are compared to hot fire test data for several different leak path situations. Investigated in the hot fire test program were nozzle joint-4 O-ring erosion sensitivities to leak path width in both open and confined joint geometries. Model predictions were in generally good agreement with the test data for the confined leak path cases. Worst case flight predictions are provided using the test-calibrated model. Analysis issues are discussed based on model calibration procedures.

  10. Augmenting a Ballet Dance Show Using the Dancer's Emotion: Conducting Joint Research in Dance and Computer Science

    NASA Astrophysics Data System (ADS)

    Clay, Alexis; Delord, Elric; Couture, Nadine; Domenger, Gaël

    We describe the joint research that we conduct in gesture-based emotion recognition and virtual augmentation of a stage, bridging together the fields of computer science and dance. After establishing a common ground for dialogue, we could conduct a research process that equally benefits both fields. As computer scientists, dance is a perfect application case. Dancer's artistic creativity orient our research choices. As dancers, computer science provides new tools for creativity, and more importantly a new point of view that forces us to reconsider dance from its fundamentals. In this paper we hence describe our scientific work and its implications on dance. We provide an overview of our system to augment a ballet stage, taking a dancer's emotion into account. To illustrate our work in both fields, we describe three events that mixed dance, emotion recognition and augmented reality.

  11. [Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].

    PubMed

    Acevedo González, Juan C; Quintero Oliveros, Silvia

    2015-01-01

    Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  12. Increasing Running Step Rate Reduces Patellofemoral Joint Forces

    PubMed Central

    Lenhart, Rachel L.; Thelen, Darryl G.; Wille, Christa M.; Chumanov, Elizabeth S.; Heiderscheit, Bryan C.

    2013-01-01

    Purpose Increasing step rate has been shown to elicit changes in joint kinematics and kinetics during running, and has been suggested as a possible rehabilitation strategy for runners with patellofemoral pain. The purpose of this study was to determine how altering step rate affects internal muscle forces and patellofemoral joint loads, and then to determine what kinematic and kinetic factors best predict changes in joint loading. Methods We recorded whole body kinematics of 30 healthy adults running on an instrumented treadmill at three step rate conditions (90%, 100%, and 110% of preferred step rate). We then used a 3D lower extremity musculoskeletal model to estimate muscle, patellar tendon, and patellofemoral joint forces throughout the running gait cycles. Additionally, linear regression analysis allowed us to ascertain the relative influence of limb posture and external loads on patellofemoral joint force. Results Increasing step rate to 110% of preferred reduced peak patellofemoral joint force by 14%. Peak muscle forces were also altered as a result of the increased step rate with hip, knee and ankle extensor forces, and hip abductor forces all reduced in mid-stance. Compared to the 90% step rate condition, there was a concomitant increase in peak rectus femoris and hamstring loads during early and late swing, respectively, at higher step rates. Peak stance phase knee flexion decreased with increasing step rate, and was found to be the most important predictor of the reduction in patellofemoral joint loading. Conclusion Increasing step rate is an effective strategy to reduce patellofemoral joint forces and could be effective in modulating biomechanical factors that can contribute to patellofemoral pain. PMID:23917470

  13. Modeling of Human Joint Structures.

    DTIC Science & Technology

    1982-09-01

    Acromioclavicular Joint .... ............. ... 20 Glenohumeral Joint .... ................ . 20 HIP JOINT .................. ...... 21 Iliofemoral Ligament...clavicle articulates with the manubrium of the sternum, and the acromioclavicular joint, where the clavicle articulates with the acromion process of the...the interclavicular ligament. Acromioclavicular Joint This articulation between the distal end of the clavicle and the acromion of the scapula is

  14. Radiographic followup of joints injected with triamcinolone hexacetonide for the management of childhood arthritis.

    PubMed

    Sparling, M; Malleson, P; Wood, B; Petty, R

    1990-06-01

    Evidence of deleterious effects following intraarticular injection of triamcinolone hexacetonide was sought through a review of radiographs of 145 joints of 55 children with chronic arthritis. Possible deleterious effects were noted in 16 joints of 11 patients. These effects included: small patella (2 joints), patellar osteochondritis dissecans (1 joint), periarticular calcification (9 joints), intraarticular tibial bony spur (1 joint), avascular necrosis of the distal radial epiphysis (2 joints), and avascular necrosis of the proximal femoral epiphysis (1 joint). Only the latter possible complication was symptomatic. Serial radiographs of 76 joints of 30 children showed mild progressive changes compatible with the underlying disease, except in the hip joint, where changes were more severe. The intraarticular injection of triamcinolone hexacetonide is a procedure that appears to be associated with an acceptably low frequency of radiologic abnormalities for many joints in children with chronic arthritis, but its effects on the hip joint remain uncertain.

  15. Knee joint distraction compared with high tibial osteotomy: a randomized controlled trial.

    PubMed

    van der Woude, J A D; Wiegant, K; van Heerwaarden, R J; Spruijt, S; van Roermund, P M; Custers, R J H; Mastbergen, S C; Lafeber, F P J G

    2017-03-01

    Both, knee joint distraction as a relatively new approach and valgus-producing opening-wedge high tibial osteotomy (HTO), are knee-preserving treatments for knee osteoarthritis (OA). The efficacy of knee joint distraction compared to HTO has not been reported. Sixty-nine patients with medial knee joint OA with a varus axis deviation of <10° were randomized to either knee joint distraction (n = 23) or HTO (n = 46). Questionnaires were assessed at baseline and 3, 6, and 12 months. Joint space width (JSW) as a surrogate measure for cartilage thickness was determined on standardized semi-flexed radiographs at baseline and 1-year follow-up. All patient-reported outcome measures (PROMS) improved significantly over 1 year (at 1 year p < 0.02) in both groups. At 1 year, the HTO group showed slightly greater improvement in 4 of the 16 PROMS (p < 0.05). The minimum medial compartment JSW increased 0.8 ± 1.0 mm in the knee joint distraction group (p = 0.001) and 0.4 ± 0.5 mm in the HTO group (p < 0.001), with minimum JSW improvement in favour of knee joint distraction (p = 0.05). The lateral compartment showed a small increase in the knee joint distraction group and a small decrease in the HTO group, leading to a significant increase in mean JSW for knee joint distraction only (p < 0.02). Cartilaginous repair activity, as indicated by JSW, and clinical outcome improvement occurred with both, knee joint distraction and HTO. These findings suggest that knee joint distraction may be an alternative therapy for medial compartmental OA with a limited mechanical leg malalignment. Randomized controlled trial, Level I.

  16. Joint Chiefs of Staff > Media

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Media News Videos Chairman's

  17. Incidence of the coracoclavicular joint in South African populations.

    PubMed Central

    Nalla, S; Asvat, R

    1995-01-01

    The presence of a diarthrotic coracoclavicular joint, as represented by an articular facet on the conoid tubercle of the clavicle and the superior surface of the coracoid process of the scapula, was investigated. The sample consisted of 60 white and 180 black South African (60 Sotho, 60 Xhosa and 60 Zulu) skeletons. Each group consisted of 30 male and 30 female skeletons. The presence of the articular facet was recorded as either bilateral, unilateral left or unilateral right. The effect of clavicular length, scapular size and first rib angle on the presence of the coracoclavicular joint was also investigated. The presence of the articular facet was noted in 23 (9.6%) of the 240 individuals studied. Of these 23 individuals, 6 (26.1%) were white and 17 (73.9%) were black. Males (56.5%) presented a higher incidence of this anomaly than females (43.5%). The articular facet occurred bilaterally in 47.9% (11/23), unilaterally on the left in 30.4% (7/23) and unilaterally on the right in 21.7% (5/23). Sexual, racial and tribal differences were not statistically significant. Individuals possessing the joint showed statistically significantly (P < 0.01) larger scapulae (increased border lengths and superior angles), longer clavicles and longer first ribs. No statistically significant differences in the first rib angles were observed between individuals who possessed the joint and those who did not, thus implying similar thoracic inlet size. It is proposed that the aforementioned morphometry of the scapulae, clavicles and first ribs may restrict associated movements of the scapulae, resulting in the development of the coracoclavicular joint. Images Fig. 4 Fig. 5 PMID:7559137

  18. Haemophilia Joint Health Score in healthy adults playing sports.

    PubMed

    Sluiter, D; Foppen, W; de Kleijn, P; Fischer, K

    2014-03-01

    To evaluate outcome of prophylactic clotting factor replacement in children with haemophilia, the Haemophilia Joint Health Score (HJHS) was developed aiming at scoring early joint changes in children aged 4-18. The HJHS has been used for adults on long-term prophylaxis but interpretation of small changes remains difficult. Some changes in these patients may be due to sports-related injuries. Evaluation of HJHS score in healthy adults playing sports could improve the interpretation of this score in haemophilic patients. The aim of this study was to evaluate the HJHS scores in a cohort of young, healthy men participating in sports. Concomitant with a project collecting MRI images of ankles and knees in normal young adults, HJHS scores were assessed in 30 healthy men aged 18-26, participating in sports one to three times per week. One physiotherapist assessed their clinical function using the HJHS 2.1. History of joint injuries was documented. MRI images were scored by a single radiologist, using the International Prophylaxis Study Group additive MRI score. Median age of the study group was 24.3 years (range 19.0-26.4) and median frequency of sports activities was three times per week (range 1-4). Six joints (five knees, one ankle) had a history of sports-related injury. The median overall HJHS score was 0 out of 124 (range 0-3), with 60% of subjects showing no abnormalities on HJHS. All joints were normal on MRI. These results suggest that frequent sports participation and related injuries are not related with abnormalities in HJHS scores. © 2013 John Wiley & Sons Ltd.

  19. SouthWest Elevation, Plan Showing Deck Framing, Deck Plan, Plan of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    South-West Elevation, Plan Showing Deck Framing, Deck Plan, Plan of Collar Beams, Etc., Typical Framing Details, End Elevations, Elevation of Scarf Top Chord, Joint Details - Perrine's Bridge, Spanning Wallkill River, Rifton, Ulster County, NY

  20. Predictive value of bone scintigraphy for the detection of joint involvement in Behçet's disease: Dermatologists' perspectives.

    PubMed

    Seo, Jimyung; Lee, Minseok; Choi, Min Ju; Zheng, Zhenlong; Cho, Arthur; Bang, Dongsik; Kim, Do Young

    2015-01-01

    Behçet's disease (BD) is a multisystemic inflammatory disease with articular involvement. Non-specific arthralgia without objective signs of arthritis, such as swelling or effusion, is common in such patients. Thus, an accurate diagnosis of joint involvement may be challenging for dermatologists. To evaluate the validity of (99m)Tc-methylene diphosphonate (Tc-99m-MDP) bone scintigraphy for joint involvement assessment in patients with BD. In 211 patients with BD who had scintigraphic evaluations due to joint symptoms, agreement between bone scintigraphy findings and clinically evaluated joint complaints was retrospectively assessed using Cohen's kappa (κ) statistic. A patient subset (n = 104) showing agreement between joint complaints and scintigraphy results was re-evaluated by a rheumatologist to determine the level of diagnostic specificity attained by combining bone scintigraphy with clinical examinations of dermatologists. The total kappa value (211 patients) was 0.604, indicating fair agreement between joint complaints and scintigraphy results. Individual analysis of eleven joint categories revealed statistically significant correlations for wrist (κ = 0.677), shoulder (κ = 0.661), and foot joints (κ = 0.618). Of the 104 referrals to a rheumatologist, 95 (91.34%) were confirmed as having BD-associated articular involvement. Joint acral areas (e.g., foot, hand, wrist and shoulder) that had the highest kappa value correlations also ranked highest in diagnostic specificity. Bone scintigraphy presents a simple and useful option for dermatologists to assess joint involvement in BD patients, especially for specific anatomic sites.

  1. Microseismic monitoring of columnar jointed basalt fracture activity: a trial at the Baihetan Hydropower Station, China

    NASA Astrophysics Data System (ADS)

    Chen, Bing-Rui; Li, Qing-Peng; Feng, Xia-Ting; Xiao, Ya-Xun; Feng, Guang-Liang; Hu, Lian-Xing

    2014-10-01

    Severe stress release has occurred to the surrounding rocks of the typically columnar jointed basalt after excavation at the Baihetan Hydropower Station, Jinsha River, China, where cracking, collapse, and other types of failure may take place occasionally due to relaxation fracture. In order to understand the relaxation fracture characteristics of the columnar jointed basalt in the entire excavation process at the diversion tunnel of the Baihetan Hydropower Station, real-time microseismic monitoring tests were performed. First, the applicability of a geophone and accelerometer was analyzed in the columnar jointed basalt tunnel, and the results show that the accelerometer was more applicable to the cracking monitoring of the columnar jointed basalt. Next, the waveform characteristics of the microseismic signals were analyzed, and the microseismic signals were identified as follows: rock fracture signal, drilling signal, electrical signal, heavy vehicle passing signal, and blast signal. Then, the attenuation characteristics of the microseismic signals in the columnar jointed basalt tunnel were studied, as well as the types and characteristics of the columnar jointed basalt fracture. Finally, location analysis was conducted on the strong rock fracture events, in which four or more sensors were triggered, to obtain the temporal and spatial evolution characteristics and laws of the columnar jointed basalt relaxation fracture after excavation. The test results are not only of important reference value to the excavation and support of diversion tunnel at the Baihetan Hydropower Station, but also of great referential significance and value to the conduction of similar tests.

  2. Nonlinear structural joint model updating based on instantaneous characteristics of dynamic responses

    NASA Astrophysics Data System (ADS)

    Wang, Zuo-Cai; Xin, Yu; Ren, Wei-Xin

    2016-08-01

    This paper proposes a new nonlinear joint model updating method for shear type structures based on the instantaneous characteristics of the decomposed structural dynamic responses. To obtain an accurate representation of a nonlinear system's dynamics, the nonlinear joint model is described as the nonlinear spring element with bilinear stiffness. The instantaneous frequencies and amplitudes of the decomposed mono-component are first extracted by the analytical mode decomposition (AMD) method. Then, an objective function based on the residuals of the instantaneous frequencies and amplitudes between the experimental structure and the nonlinear model is created for the nonlinear joint model updating. The optimal values of the nonlinear joint model parameters are obtained by minimizing the objective function using the simulated annealing global optimization method. To validate the effectiveness of the proposed method, a single-story shear type structure subjected to earthquake and harmonic excitations is simulated as a numerical example. Then, a beam structure with multiple local nonlinear elements subjected to earthquake excitation is also simulated. The nonlinear beam structure is updated based on the global and local model using the proposed method. The results show that the proposed local nonlinear model updating method is more effective for structures with multiple local nonlinear elements. Finally, the proposed method is verified by the shake table test of a real high voltage switch structure. The accuracy of the proposed method is quantified both in numerical and experimental applications using the defined error indices. Both the numerical and experimental results have shown that the proposed method can effectively update the nonlinear joint model.

  3. Experimental joint immobilization in guinea pigs. Effects on the knee joint

    NASA Technical Reports Server (NTRS)

    Marcondesdesouza, J. P.; Machado, F. F.; Sesso, A.; Valeri, V.

    1980-01-01

    In young and adult guinea pigs, the aftermath experimentally induced by the immobilization of the knee joint in hyperextended forced position was studied. Joint immobilization which varied from one to nine weeks was attained by plaster. Eighty knee joints were examined macro and microscopically. Findings included: (1) muscular hypotrophy and joint stiffness in all animals, directly proportional to the length of immobilization; (2) haemoarthrosis in the first week; (3) intra-articular fibrous tissue proliferation ending up with fibrous ankylosis; (4) hyaline articular cartilage erosions; (5) various degrees of destructive menisci changes. A tentative explanation of the fibrous tissue proliferation and of the cartilage changes is offered.

  4. A field evaluation of Transflex bridge joint performance.

    DOT National Transportation Integrated Search

    1972-01-01

    Presented are the results of a field evaluation of the various types of the General Tire Transflex joint known to be in use in Virginia. An effort was made, whenever possible, to qualitatively evaluate the joints with respect to their (1) watertightn...

  5. Experimental investigation on the failure of T-joints at elevated temperature under unaxial loading

    NASA Astrophysics Data System (ADS)

    Bahri, N. F.; Afendi, M.; Razlan, Z. M.; Nor, A.; Baharuddin, S. A.

    2017-09-01

    In this study, the mechanical properties and maximum failure load of a bulk and T-joints subjected to tensile loading were investigated experimentally. A bulk and the T-joint specimens were fabricated and tested in order to investigate the effects of temperature conditions on the failure of the joints. The adherent and adhesive used for T-joint are 304 L stainless steel and Hysol E 214 HP with the adhesive thickness of 1.0 mm. The tensile test of the bulk specimen and adhesively T-joint were conducted by using a universal testing machine (UTM) at room temperature (RT), 55 °C, 75 °C, 100 °C and 120 °C, respectively. It was found that as the temperature increases, the failure force strength decreases for bulk and T-joint specimen. Data obtained from the tests at 120 °C showed the failure force of the bulk adhesive decreased by approximately 44 % compared to the specimen tested at RT. Next, the bulk of Hysol failure force result was compared with Araldite at RT and 100 °C. Araldite data was taken from the previous study [1]. It has also been found that the bulk for Hysol has higher failure force compared to Araldite at RT and 100 °C.

  6. Correlation between MRI evidence of degenerative condylar surface changes, induction of articular disc displacement and pathological joint sounds in the temporomandibular joint.

    PubMed

    Honda, Kosuke; Natsumi, Yoshiko; Urade, Masahiro

    2008-12-01

    The relationship of bony changes in the condylar surfaces in articular disc displacement without reduction in temporomandibular joint (TMJ) was investigated using diagnostic imaging. The study also evaluated whether the bony changes in the condylar surfaces limit disc and condyle motion, and produce pathological joint sounds. Thirty-seven joints in 28 patients diagnosed with degenerative bony changes in the condylar surfaces radiographically and anterior disc displacement without reduction using magnetic resonance imaging (MRI) were studied. The bony changes were assessed by radiographic examination and classified into two types: pathological bone changes (PBCs) including erosion, osteophyte formation and deformity, and adaptive bone changes (ABCs) including flattening and concavity. MRI was performed on the TMJ to examine the configuration and position of the discs. Joint sounds in the TMJ were determined using electrovibratograghy with a joint vibration analysis. The articular disc motion to the condyle in the PBC group was smaller than in the ABC group irrespective of the configuration of the disc, even though there were no significant differences between the two types of bony changes in the disc position during jaw closing. The joint vibration analysis of the TMJ showed that joint sounds with a higher frequency were observed in the PBC group than in the ABC group. High energy levels needed to produce the higher frequencies (over 300 Hz) were observed only in the PBC group.

  7. Investigation Leads to Improved Understanding of Space Shuttle RSRM Internal Insulation Joints

    NASA Technical Reports Server (NTRS)

    McWhorter, Bruce B.; Bolton, Doug E.; Hicken, Steve V.; Allred, Larry D.; Cook, Dave J.

    2003-01-01

    The Space Shuttle Reusable Solid Rocket Motor (RSRM) uses an internal insulation J-joint design for the mated insulation interface between two assembled RSRM segments. In this assembled (mated) segment configuration, this J-joint design serves as a thermal barrier to prevent hot gases from affecting the case field joint metal surfaces and O-rings. A pressure sensitive adhesive (PSA) provides some adhesion between the two mated insulation surfaces. In 1995, after extensive testing, a new ODC-free PSA (free of ozone depleting chemicals) was selected for flight on RSRM-55 (STS-78). Post-flight inspection revealed that the J-joint, equipped with the new ODC-free PSA, did not perform well. Hot gas seeped inside the J-joint interface. Although not a flight safety threat, the J-joint hot gas intrusion on RSRM-55 was a mystery to the investigators since the PSA had previously worked well on a full-scale static test. A team was assembled to study the J-joint and PSA further. All J-joint design parameters, measured data, and historical performance data were re-reviewed and evaluated by subscale testing and analysis. Although both the ODC-free and old PSA were weakened by humidity, the ODC-free PSA strength was lower to start with. Another RSRM full-scale static test was conducted in 1998 and intentionally duplicated the gas intrusion. This test, along with many concurring tests, showed that if a J-joint was 1) mated with the new ODC-free PSA, 2) exposed to a history of high humidity (Kennedy Space Center levels), and 3) also a joint which experienced significant but normal joint motion (J-joint deformation resulting from motor pressurization dynamics) then that J-joint would open (allow gas intrusion) during motor operation. When all of the data from the analyses, subscale tests, and full-scale tests were considered together, a theory emerged. Most of the joint motion on the RSRM occurs early in motor operation at which point the J-joints are pulled into tension. If the new

  8. Thermal imaging in screening of joint inflammation and rheumatoid arthritis in children.

    PubMed

    Lasanen, R; Piippo-Savolainen, E; Remes-Pakarinen, T; Kröger, L; Heikkilä, A; Julkunen, P; Karhu, J; Töyräs, J

    2015-02-01

    Potential of modern thermal imaging for screening and differentiation of joint inflammation has not been assessed in child and juvenile patient populations, typically demanding groups in diagnostics of musculoskeletal disorders. We hypothesize that thermal imaging can detect joint inflammation in patients with juvenile idiopathic arthritis or autoimmune disease with arthritis such as systemic lupus erythematosus. To evaluate the hypothesis, we studied 58 children exhibiting symptoms of joint inflammation. First, the patients' joints were examined along clinical procedure supplemented with ultrasound imaging when deemed necessary by the clinician. Second, thermal images were acquired from patients' knees and ankles. Results of thermal imaging were compared to clinical evaluations in knee and ankle. The temperatures were significantly (pmax = 0.044, pmean < 0.001) higher in inflamed ankle joints, but not in inflamed knee joints. No significant difference was found between the skin surface temperatures of medial and lateral aspects of ankle joints. In knee joints the mean temperatures of medial and lateral aspect differed significantly (p = 0.004). We have demonstrated that thermal imaging may have potential for detecting joint inflammation in ankle joints of children. For knee joints our results are inconclusive and further research is warranted.

  9. Preload Monitoring of Bolted L-Shaped Lap Joints Using Virtual Time Reversal Method.

    PubMed

    Du, Fei; Xu, Chao; Wu, Guannan; Zhang, Jie

    2018-06-13

    L-shaped bolt lap joints are commonly used in aerospace and civil structures. However, bolt joints are frequently subjected to loosening, and this has a significant effect on the safety and reliability of these structures. Therefore, bolt preload monitoring is very important, especially at the early stage of loosening. In this paper, a virtual time reversal guided wave method is presented to monitor preload of bolted L-shaped lap joints accurately and simply. In this method, a referenced reemitting signal (RRS) is extracted from the bolted structure in fully tightened condition. Then the RRS is utilized as the excitation signal for the bolted structure in loosening states, and the normalized peak amplitude of refocused wave packet is used as the tightness index (TI A ). The proposed method is experimentally validated by L-shaped bolt joints with single and multiple bolts. Moreover, the selections of guided wave frequency and tightness index are also discussed. The results demonstrate that the relationship between TI A and bolt preload is linear. The detection sensitivity is improved significantly compared with time reversal (TR) method, particularly when bolt loosening is at its embryo stage. The results also show that TR method is an effective method for detection of the number of loosening bolts.

  10. Multiscale biomechanical responses of adapted bone-periodontal ligament-tooth fibrous joints

    PubMed Central

    Jang, Andrew T.; Merkle, Arno; Fahey, Kevin; Gansky, Stuart A.; Ho, Sunita P.

    2015-01-01

    Reduced functional loads cause adaptations in organs. In this study, temporal adaptations of bone-ligament-tooth fibrous joints to reduced functional loads were mapped using a holistic approach. Systematic studies were performed to evaluate organ-level and tissue-level adaptations in specimens harvested periodically from rats given powder food for 6 months (N = 60 over 8,12,16,20, and 24 weeks). Bone-periodontal ligament (PDL)-tooth fibrous joint adaptation was evaluated by comparing changes in joint stiffness with changes in functional space between the tooth and alveolar bony socket. Adaptations in tissues included mapping changes in the PDL and bone architecture as observed from collagen birefringence, bone hardness and volume fraction in rats fed soft foods (soft diet, SD) compared to those fed hard pellets as a routine diet (hard diet, HD). In situ biomechanical testing on harvested fibrous joints revealed increased stiffness in SD groups (SD:239-605 N/mm) (p<0.05) at 8 and 12 weeks. Increased joint stiffness in early development phase was due to decreased functional space (at 8wks change in functional space was −33 µm, at 12wks change in functional space was −30 µm) and shifts in tissue quality as highlighted by birefringence, architecture and hardness. These physical changes were not observed in joints that were well into function, that is, in rodents older than 12 weeks of age. Significant adaptations in older groups were highlighted by shifts in bone growth (bone volume fraction 24wks: Δ-0.06) and bone hardness (8wks: Δ−0.04 GPa, 16 wks: Δ−0.07 GPa, 24wks: Δ−0.06 GPa). The response rate (N/s) of joints to mechanical loads decreased in SD groups. Results from the study showed that joint adaptation depended on age. The initial form-related adaptation (observed change in functional space) can challenge strain-adaptive nature of tissues to meet functional demands with increasing age into adulthood. The coupled effect between functional space in

  11. Microstructural evolution and IMCs growth behavior of Sn-58Bi-0.25Mo solder joint during aging treatment

    NASA Astrophysics Data System (ADS)

    Yang, Li; Zhu, Lu; Zhang, Yaocheng; Zhou, Shiyuan; Xiong, Yifeng; Wu, Pengcheng

    2018-02-01

    The microstructural evolution and IMCs growth behavior of Sn-58Bi and Sn-58Bi-0.25Mo solder joints were investigated. The results showed that the microstructure is coarsened, the IMCs layer thickness is increased and the tensile strength of Sn-58Bi and Sn-58Bi-0.25Mo solder joints is decreased with increasing aging time and temperature. Aging temperature is the key factor that causes the excessive IMCs growth of the solder joint compared with aging time, and the activation energy of IMCs layer growth of Sn-58Bi and Sn-58Bi-0.25Mo solder joints is 48.94 kJ mol-1 and 53.79 kJ mol-1, respectively. During the aging treatment, the microstructure of Sn-58Bi solder joint is refined by adding Mo nanoparticles, and the appropriate IMCs layer thickness and improved mechanical properties are obtained by Sn-58Bi-0.25Mo solder joint.

  12. Joint reconstruction via coupled Bregman iterations with applications to PET-MR imaging

    NASA Astrophysics Data System (ADS)

    Rasch, Julian; Brinkmann, Eva-Maria; Burger, Martin

    2018-01-01

    Joint reconstruction has recently attracted a lot of attention, especially in the field of medical multi-modality imaging such as PET-MRI. Most of the developed methods rely on the comparison of image gradients, or more precisely their location, direction and magnitude, to make use of structural similarities between the images. A challenge and still an open issue for most of the methods is to handle images in entirely different scales, i.e. different magnitudes of gradients that cannot be dealt with by a global scaling of the data. We propose the use of generalized Bregman distances and infimal convolutions thereof with regard to the well-known total variation functional. The use of a total variation subgradient respectively the involved vector field rather than an image gradient naturally excludes the magnitudes of gradients, which in particular solves the scaling behavior. Additionally, the presented method features a weighting that allows to control the amount of interaction between channels. We give insights into the general behavior of the method, before we further tailor it to a particular application, namely PET-MRI joint reconstruction. To do so, we compute joint reconstruction results from blurry Poisson data for PET and undersampled Fourier data from MRI and show that we can gain a mutual benefit for both modalities. In particular, the results are superior to the respective separate reconstructions and other joint reconstruction methods.

  13. Microstructures and Mechanical Properties of 12Cr1MoVG Tube Welded Joints With/Without Post-weld Heat Treatment

    NASA Astrophysics Data System (ADS)

    Wang, Jingjing; Sun, Jian; Yu, Xinhai; Chen, Guohong; Fu, Qiuhua; Gao, Chao; Tang, Wenming

    2017-10-01

    Small-caliber, thick-wall 12Cr1MoVG seamless steel tube welded joints were fabricated in this study by gas tungsten arc welding and shielded metal arc welding techniques, then the microstructures, mechanical properties, and residual stress distributions of the joints with or without post-weld heat treatment (PWHT) were compared. The welded joints are mainly composed of bcc ferrite (F), Fe3C, and M7C3 carbides. PWHT did not cause an apparent microstructure evolution in the joints, but promoted granular pearlite decomposition and growth of F grains and carbides, therefore decreasing the yield, tensile strength, and hardness while increasing the impact toughness and elongation of the welded joints. PWHT also released the circumferential residual stress and altered the stress state in the joint from tensile to compressive. Although the mechanical properties and bending performance of the small-caliber, thick-wall 12Cr1MoVG seamless welded joints without PWHT are acceptable, our results show that the joints with PWHT are more reliable.

  14. Fatigue properties of dissimilar metal laser welded lap joints

    NASA Astrophysics Data System (ADS)

    Dinsley, Christopher Paul

    This work involves laser welding austenitic and duplex stainless steel to zinc-coated mild steel, more specifically 1.2mm V1437, which is a Volvo Truck Coiporation rephosphorised mild steel. The work investigates both tensile and lap shear properties of similar and dissimilar metal laser welded butt and lap joints, with the majority of the investigation concentrating on the fatigue properties of dissimilar metal laser welded lap joints. The problems encountered when laser welding zinc-coated steel are addressed and overcome with regard to dissimilar metal lap joints with stainless steel. The result being the production of a set of guidelines for laser welding stainless steel to zinc-coated mild steel. The stages of laser welded lap joint fatigue life are defined and the factors affecting dissimilar metal laser welded lap joint fatigue properties are analysed and determined; the findings suggesting that dissimilar metal lap joint fatigue properties are primarily controlled by the local stress at the internal lap face and the early crack growth rate of the material at the internal lap face. The lap joint rotation, in turn, is controlled by sheet thickness, weld width and interfacial gap. Laser welded lap joint fatigue properties are found to be independent of base material properties, allowing dissimilar metal lap joints to be produced without fatigue failure occurring preferentially in the weaker parent material, irrespective of large base material property differences. The effects of Marangoni flow on the compositions of the laser weld beads are experimentally characterised. The results providing definite proof of the stirring mechanism within the weld pool through the use of speeds maps for chromium and nickel. Keywords: Laser welding, dissimilar metal, Zinc-coated mild steel, Austenitic stainless steel, Duplex stainless steel, Fatigue, Lap joint rotation, Automotive.

  15. Microstructure and mechanical properties of friction stir lap welded Mg/Al joint assisted by stationary shoulder

    NASA Astrophysics Data System (ADS)

    Ji, Shude; Li, Zhengwei

    2017-11-01

    Using magnesium alloy as upper sheet, 3 mm-thick AZ31 magnesium alloy and 6061 aluminum alloy were joined using friction stir lap welding assisted by stationary shoulder. The effects of tool rotating speed on cross-sections, microstructure and mechanical properties of Mg/Al lap joints were mainly discussed. Results showed that stationary shoulder contributed to joint formation, by which stir zones (SZ) were characterized by big onion rings after welding. Because of the big forging force exerted by stationary shoulder, the upper region of hook was well bonded. SZ showed much higher hardness because of intermetallic compounds (IMCs). The bonding conditions at the base material (BM)/SZ interface at advancing side and the hook region played important roles on joint lap shear properties. The X-ray diffraction pattern analysis revealed that the main IMCs were Al3Mg2 and Al12Mg17.

  16. Impact of mechanical heterogeneity on joint density in a welded ignimbrite

    NASA Astrophysics Data System (ADS)

    Soden, A. M.; Lunn, R. J.; Shipton, Z. K.

    2016-08-01

    Joints are conduits for groundwater, hydrocarbons and hydrothermal fluids. Robust fluid flow models rely on accurate characterisation of joint networks, in particular joint density. It is generally assumed that the predominant factor controlling joint density in layered stratigraphy is the thickness of the mechanical layer where the joints occur. Mechanical heterogeneity within the layer is considered a lesser influence on joint formation. We analysed the frequency and distribution of joints within a single 12-m thick ignimbrite layer to identify the controls on joint geometry and distribution. The observed joint distribution is not related to the thickness of the ignimbrite layer. Rather, joint initiation, propagation and termination are controlled by the shape, spatial distribution and mechanical properties of fiamme, which are present within the ignimbrite. The observations and analysis presented here demonstrate that models of joint distribution, particularly in thicker layers, that do not fully account for mechanical heterogeneity are likely to underestimate joint density, the spatial variability of joint distribution and the complex joint geometries that result. Consequently, we recommend that characterisation of a layer's compositional and material properties improves predictions of subsurface joint density in rock layers that are mechanically heterogeneous.

  17. Effect of Board Thickness on Sn-Ag-Cu Joint Interconnect Mechanical Shock Performance

    NASA Astrophysics Data System (ADS)

    Lee, Tae-Kyu; Xie, Weidong

    2014-12-01

    The mechanical stability of solder joints with Sn-Ag-Cu alloy joints on various board thicknesses was investigated with a high G level shock environment. A test vehicle with three different board thicknesses was used for board drop shock performance tests. These vehicles have three different strain and shock level condition couples per board, and are used to identify the joint stability and failure modes based on the board responses. The results revealed that joint stability is sensitive to board thickness. The board drop shock test showed that the first failure location shifts from the corner location near the standoff to the center with increased board thickness due to the shock wave response. From analysis of the thickness variation and failure cycle number, the strain rate during the pulse strain cycle is the dominant factor, which defines the life cycle number per board thickness, and not the maximum strain value. The failure location shift and the shock performance differentiation are discussed from the perspective of maximum principal strain, cycle frequency and strain rate per cycle.

  18. [Determination of joint contact area using MRI].

    PubMed

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  19. Experiments and simulation for 6061-T6 aluminum alloy resistance spot welded lap joints

    NASA Astrophysics Data System (ADS)

    Florea, Radu Stefanel

    This comprehensive study is the first to quantify the fatigue performance, failure loads, and microstructure of resistance spot welding (RSW) in 6061-T6 aluminum (Al) alloy according to welding parameters and process sensitivity. The extensive experimental, theoretical and simulated analyses will provide a framework to optimize the welding of lightweight structures for more fuel-efficient automotive and military applications. The research was executed in four primary components. The first section involved using electron back scatter diffraction (EBSD) scanning, tensile testing, laser beam profilometry (LBP) measurements, and optical microscopy(OM) images to experimentally investigate failure loads and deformation of the Al-alloy resistance spot welded joints. Three welding conditions, as well as nugget and microstructure characteristics, were quantified according to predefined process parameters. Quasi-static tensile tests were used to characterize the failure loads in specimens based upon these same process parameters. Profilometer results showed that increasing the applied welding current deepened the weld imprints. The EBSD scans revealed the strong dependency between the grain sizes and orientation function on the process parameters. For the second section, the fatigue behavior of the RSW'ed joints was experimentally investigated. The process optimization included consideration of the forces, currents, and times for both the main weld and post-heating. Load control cyclic tests were conducted on single weld lap-shear joint coupons to characterize the fatigue behavior in spot welded specimens. Results demonstrate that welding parameters do indeed significantly affect the microstructure and fatigue performance for these welds. The third section comprised residual strains of resistance spot welded joints measured in three different directions, denoted as in-plane longitudinal, in-plane transversal, and normal, and captured on the fusion zone, heat affected zone

  20. Potential of optical spectral transmission measurements for joint inflammation measurements in rheumatoid arthritis patients

    NASA Astrophysics Data System (ADS)

    Meier, A. J. Louise; Rensen, Wouter H. J.; de Bokx, Pieter K.; de Nijs, Ron N. J.

    2012-08-01

    Frequent monitoring of rheumatoid arthritis (RA) patients enables timely treatment adjustments and improved outcomes. Currently this is not feasible due to a shortage of rheumatologists. An optical spectral transmission device is presented for objective assessment of joint inflammation in RA patients, while improving diagnostic accuracy and clinical workflow. A cross-sectional, nonrandomized observational study was performed with this device. In the study, 77 proximal interphalangeal (PIP) joints in 67 patients have been analyzed. Inflammation of these PIP joints was also assessed by a rheumatologist with a score varying from 1 (not inflamed) to 5 (severely inflamed). Out of 77 measurements, 27 were performed in moderate to strongly inflamed PIP joints. Comparison between the clinical assessment and an optical measurement showed a correlation coefficient r=0.63, p<0.001, 95% CI [0.47, 0.75], and a ROC curve (AUC=0.88) that shows a relative good specificity and sensitivity. Optical spectral transmission measurements in a single joint correlate with clinical assessment of joint inflammation, and therefore might be useful in monitoring joint inflammation in RA patients.

  1. Quantitative metal magnetic memory reliability modeling for welded joints

    NASA Astrophysics Data System (ADS)

    Xing, Haiyan; Dang, Yongbin; Wang, Ben; Leng, Jiancheng

    2016-03-01

    Metal magnetic memory(MMM) testing has been widely used to detect welded joints. However, load levels, environmental magnetic field, and measurement noises make the MMM data dispersive and bring difficulty to quantitative evaluation. In order to promote the development of quantitative MMM reliability assessment, a new MMM model is presented for welded joints. Steel Q235 welded specimens are tested along the longitudinal and horizontal lines by TSC-2M-8 instrument in the tensile fatigue experiments. The X-ray testing is carried out synchronously to verify the MMM results. It is found that MMM testing can detect the hidden crack earlier than X-ray testing. Moreover, the MMM gradient vector sum K vs is sensitive to the damage degree, especially at early and hidden damage stages. Considering the dispersion of MMM data, the K vs statistical law is investigated, which shows that K vs obeys Gaussian distribution. So K vs is the suitable MMM parameter to establish reliability model of welded joints. At last, the original quantitative MMM reliability model is first presented based on the improved stress strength interference theory. It is shown that the reliability degree R gradually decreases with the decreasing of the residual life ratio T, and the maximal error between prediction reliability degree R 1 and verification reliability degree R 2 is 9.15%. This presented method provides a novel tool of reliability testing and evaluating in practical engineering for welded joints.

  2. Contribution of Large Region Joint Associations to Complex Traits Genetics

    PubMed Central

    Paré, Guillaume; Asma, Senay; Deng, Wei Q.

    2015-01-01

    A polygenic model of inheritance, whereby hundreds or thousands of weakly associated variants contribute to a trait’s heritability, has been proposed to underlie the genetic architecture of complex traits. However, relatively few genetic variants have been positively identified so far and they collectively explain only a small fraction of the predicted heritability. We hypothesized that joint association of multiple weakly associated variants over large chromosomal regions contributes to complex traits variance. Confirmation of such regional associations can help identify new loci and lead to a better understanding of known ones. To test this hypothesis, we first characterized the ability of commonly used genetic association models to identify large region joint associations. Through theoretical derivation and simulation, we showed that multivariate linear models where multiple SNPs are included as independent predictors have the most favorable association profile. Based on these results, we tested for large region association with height in 3,740 European participants from the Health and Retirement Study (HRS) study. Adjusting for SNPs with known association with height, we demonstrated clustering of weak associations (p = 2x10-4) in regions extending up to 433.0 Kb from known height loci. The contribution of regional associations to phenotypic variance was estimated at 0.172 (95% CI 0.063-0.279; p < 0.001), which compared favorably to 0.129 explained by known height variants. Conversely, we showed that suggestively associated regions are enriched for known height loci. To extend our findings to other traits, we also tested BMI, HDLc and CRP for large region associations, with consistent results for CRP. Our results demonstrate the presence of large region joint associations and suggest these can be used to pinpoint weakly associated SNPs. PMID:25856144

  3. A New Technique for Compensating Joint Limits in a Robot Manipulator

    NASA Technical Reports Server (NTRS)

    Litt, Jonathan; Hickman, Andre; Guo, Ten-Huei

    1996-01-01

    A new robust, optimal, adaptive technique for compensating rate and position limits in the joints of a six degree-of-freedom elbow manipulator is presented. In this new algorithm, the unmet demand as a result of actuator saturation is redistributed among the remaining unsaturated joints. The scheme is used to compensate for inadequate path planning, problems such as joint limiting, joint freezing, or even obstacle avoidance, where a desired position and orientation are not attainable due to an unrealizable joint command. Once a joint encounters a limit, supplemental commands are sent to other joints to best track, according to a selected criterion, the desired trajectory.

  4. Electromigration in solder joints and solder lines

    NASA Astrophysics Data System (ADS)

    Gan, H.; Choi, W. J.; Xu, G.; Tu, K. N.

    2002-06-01

    Electromigration may affect the reliability of flip-chip solder joints. Eutectic solder is a two-phase alloy, so its electromigration behavior is different from that in aluminum or copper interconnects. In addition, a flipchip solder joint has a built-in currentcrowding configuration to enhance electromigration failure. To better understand electromigration in SnPb and lead-free solder alloys, the authors prepared solder lines in v-grooves etched on Si (001). This article discusses the results of those tests and compares the electromigration failure modes of eutectic SnPb and SnAgCu flip-chip solder joints along with the mean-timeto-failure.

  5. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    NASA Astrophysics Data System (ADS)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  6. The Joint Master Operational Planner

    DTIC Science & Technology

    2016-04-04

    Daniel H. Hibner, United States Army Joint Forces Staff College Joint Advanced Warfighting School 7800 Hampton Blvd. Norfolk, VA 23511-1702 Approved...Operational Art. Unclass Unclass Unclass Unclassified Unlimited 66 757-443-6301 NATIONAL DEFENSE UNIVERSITY JOINT FORCES STAFF COLLEGE JOINT ADVANCED...of this paper reflect my own personal views and are not necessarily endorsed by the Joint Forces Staff College or the department of Defense. Thesis

  7. Recrystallization Behavior in SAC305 and SAC305 + 3.0POSS Solder Joints Under Thermal Shock

    NASA Astrophysics Data System (ADS)

    Han, Jing; Gu, Penghao; Ma, Limin; Guo, Fu; Liu, Jianping

    2018-04-01

    Sn-3.0Ag-0.5Cu (SAC305) and SAC305 + 3.0 polyhedral oligomeric silsesquioxanes (POSS) ball grid array (BGA) assemblies have been prepared, observed, and subjected to thermal shock. The microstructure and grain orientation evolution of the solder joints located at the same position of the package were characterized by scanning electron microscopy and electron backscattering diffraction, respectively. The results showed that the microstructure of the solder joints was refined by addition of POSS particles. In addition, compared with the single-grained or tricrystal joints normally observed in SAC305 BGA solder joints, the frequency of single-grained as-reflowed SAC305 + 3.0POSS BGA joints was greatly reduced, and the solder joints were typically composed of multicrystals with orientations separated by high-angle grain boundaries. These multicrystal joints appear to be obtained by dominant tricrystals or double tricrystals with deviation of the preferred [110] and [1\\bar{1}0] growth directions of Sn dendrites in Sn-Ag-based solder alloys during solidification from the melt. After 928 thermal shock cycles, the SAC305 solder joint had large-area recrystallization and cracks in contrast to the SAC305 + 3.0POSS solder joint located at the same position of the package, indicating that addition of POSS to SAC305 solder joints may contribute to postponement of recrystallization and subsequent crack initiation and propagation along recrystallized grain boundaries by pinning grain boundaries and movement of dislocations. This finding also confirms the double tricrystal solidification twinning nucleation behavior in Pb-free solder joints.

  8. Cellular Pressure-Actuated Joint

    NASA Technical Reports Server (NTRS)

    McGuire, John R.

    2003-01-01

    A modification of a pressure-actuated joint has been proposed to improve its pressure actuation in such a manner as to reduce the potential for leakage of the pressurizing fluid. The specific joint for which the modification is proposed is a field joint in a reusable solid-fuel rocket motor (RSRM), in which the pressurizing fluid is a mixture of hot combustion gases. The proposed modification could also be applicable to other pressure-actuated joints of similar configuration.

  9. The carry-over effect of competition in task-sharing: evidence from the joint Simon task.

    PubMed

    Iani, Cristina; Anelli, Filomena; Nicoletti, Roberto; Rubichi, Sandro

    2014-01-01

    The Simon effect, that is the advantage of the spatial correspondence between stimulus and response locations when stimulus location is a task-irrelevant dimension, occurs even when the task is performed together by two participants, each performing a go/no-go task. Previous studies showed that this joint Simon effect, considered by some authors as a measure of self-other integration, does not emerge when during task performance co-actors are required to compete. The present study investigated whether and for how long competition experienced during joint performance of one task can affect performance in a following joint Simon task. In two experiments, we required pairs of participants to perform together a joint Simon task, before and after jointly performing together an unrelated non-spatial task (the Eriksen flanker task). In Experiment 1, participants always performed the joint Simon task under neutral instructions, before and after performing the joint flanker task in which they were explicitly required either to cooperate with (i.e., cooperative condition) or to compete against a co-actor (i.e., competitive condition). In Experiment 2, they were required to compete during the joint flanker task and to cooperate during the subsequent joint Simon task. Competition experienced in one task affected the way the subsequent joint task was performed, as revealed by the lack of the joint Simon effect, even though, during the Simon task participants were not required to compete (Experiment 1). However, prior competition no longer affected subsequent performance if a new goal that created positive interdependence between the two agents was introduced (Experiment 2). These results suggest that the emergence of the joint Simon effect is significantly influenced by how the goals of the co-acting individuals are related, with the effect of competition extending beyond the specific competitive setting and affecting subsequent interactions.

  10. Mechanics of Suture Joints

    NASA Astrophysics Data System (ADS)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  11. Push-off tests and strength evaluation of joints combining shrink fitting with bonding

    NASA Astrophysics Data System (ADS)

    Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi

    1997-03-01

    Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.

  12. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    PubMed

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  13. Joint angle affects volitional and magnetically-evoked neuromuscular performance differentially.

    PubMed

    Minshull, C; Rees, D; Gleeson, N P

    2011-08-01

    This study examined the volitional and magnetically-evoked neuromuscular performance of the quadriceps femoris at functional knee joint angles adjacent to full extension. Indices of volitional and magnetically-evoked neuromuscular performance (N=15 healthy males, 23.5 ± 2.9 years, 71.5 ± 5.4 kg, 176.5 ± 5.5 cm) were obtained at 25°, 35° and 45° of knee flexion. Results showed that volitional and magnetically-evoked peak force (PF(V) and P(T)F(E), respectively) and electromechanical delay (EMD(V) and EMD(E), respectively) were enhanced by increased knee flexion. However, greater relative improvements in volitional compared to evoked indices of neuromuscular performance were observed with increasing flexion from 25° to 45° (e.g. EMD(V), EMD(E): 36% vs. 11% improvement, respectively; F([2,14])=6.8, p<0.05). There were no significant correlations between EMD(V) and EMD(E) or PF(V) and P(T)F(E), at analogous joint positions. These findings suggest that the extent of the relative differential between volitional and evoked neuromuscular performance capabilities is joint angle-specific and not correlated with performance capabilities at adjacent angles, but tends to be smaller with increased flexion. As such, effective prediction of volitional from evoked performance capabilities at both analogous and adjacent knee joint positions would lack robustness. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Room Temperature and Elevated Temperature Composite Sandwich Joint Testing

    NASA Technical Reports Server (NTRS)

    Walker, Sandra P.

    1998-01-01

    Testing of composite sandwich joint elements has been completed to verify the strength capacity of joints designed to carry specified running loads representative of a high speed civil transport wing. Static tension testing at both room and an elevated temperature of 350 F and fatigue testing at room temperature were conducted to determine strength capacity, fatigue life, and failure modes. Static tension test results yielded failure loads above the design loads for the room temperature tests, confirming the ability of the joint concepts tested to carry their design loads. However, strength reductions as large as 30% were observed at the elevated test temperature, where all failure loads were below the room temperature design loads for the specific joint designs tested. Fatigue testing resulted in lower than predicted fatigue lives.

  15. Flat H Redundant Frangible Joint Development

    NASA Technical Reports Server (NTRS)

    Brown, Chris

    2016-01-01

    Orion and Commercial Crew Program (CCP) Partners have chosen to use frangible joints for certain separation events. The joints currently available are zero failure tolerant and will be used in mission safety applications. The goal is to further develop a NASA designed redundant frangible joint that will lower flight risk and increase reliability. FY16 testing revealed a successful design in subscale straight test specimens that gained efficiency and supports Orion load requirements. Approach / Innovation A design constraint is that the redundant joint must fit within the current Orion architecture, without the need for additional vehicle modification. This limitation required a design that changed the orientation of the expanding tube assemblies (XTAs), by rotating them 90deg from the standard joint configuration. The change is not trivial and affects the fracture mechanism and structural load paths. To address these changes, the design incorporates cantilevered arms on the break plate. The shock transmission and expansion of the XTA applies force to these arms and creates a prying motion to push the plate walls outward to the point of structural failure at the notched section. The 2014 test design revealed that parts could slip during functioning wasting valuable energy needed to separate the structure with only a single XTA functioning. Dual XTA functioning fully separated the assembly showing a discrepancy can be backed up with redundancy. Work on other fully redundant systems outside NASA is limited to a few patents that have not been subjected to functionality testing Design changes to prevent unwanted slippage (with ICA funding in 2015) showed success with a single XTA. The main goal for FY 2016 was to send the new Flat H RFJ to WSTF where single XTA test failures occurred back in 2014. The plan was to gain efficiency in this design by separating the Flat H RFJ with thicker ligaments with dimensions baselined in 2014. Other modifications included geometry

  16. The Interface of Mechanics and Nociception in Joint Pathophysiology: Insights From the Facet and Temporomandibular Joints

    PubMed Central

    Sperry, Megan M.; Ita, Meagan E.; Kartha, Sonia; Zhang, Sijia; Yu, Ya-Hsin; Winkelstein, Beth

    2017-01-01

    Chronic joint pain is a widespread problem that frequently occurs with aging and trauma. Pain occurs most often in synovial joints, the body's load bearing joints. The mechanical and molecular mechanisms contributing to synovial joint pain are reviewed using two examples, the cervical spinal facet joints and the temporomandibular joint (TMJ). Although much work has focused on the macroscale mechanics of joints in health and disease, the combined influence of tissue mechanics, molecular processes, and nociception in joint pain has only recently become a focus. Trauma and repeated loading can induce structural and biochemical changes in joints, altering their microenvironment and modifying the biomechanics of their constitutive tissues, which themselves are innervated. Peripheral pain sensors can become activated in response to changes in the joint microenvironment and relay pain signals to the spinal cord and brain where pain is processed and perceived. In some cases, pain circuitry is permanently changed, which may be a potential mechanism for sustained joint pain. However, it is most likely that alterations in both the joint microenvironment and the central nervous system (CNS) contribute to chronic pain. As such, the challenge of treating joint pain and degeneration is temporally and spatially complicated. This review summarizes anatomy, physiology, and pathophysiology of these joints and the sensory pain relays. Pain pathways are postulated to be sensitized by many factors, including degeneration and biochemical priming, with effects on thresholds for mechanical injury and/or dysfunction. Initiators of joint pain are discussed in the context of clinical challenges including the diagnosis and treatment of pain. PMID:28056123

  17. Experimental evaluation of joint designs for a space-shuttle orbiter ablative leading edge

    NASA Technical Reports Server (NTRS)

    Tompkins, S. S.; Kabana, W. P.

    1975-01-01

    The thermal performance of two types of ablative leading-edge joints for a space-shuttle orbiter were tested and evaluated. Chordwise joints between ablative leading-edge segments, and spanwise joints between ablative leading-edge segments and reusable surface insulation tiles were exposed to simulated shuttle heating environments. The data show that the thermal performance of models with chordwise joints to be as good as jointless models in simulated ascent-heating and orbital cold-soak environments. The suggestion is made for additional work on the joint seals, and, in particular, on the effects of heat-induced seal-material surface irregularities on the local flow.

  18. Joint weak value for all order coupling using continuous variable and qubit probe

    NASA Astrophysics Data System (ADS)

    Kumari, Asmita; Pan, Alok Kumar; Panigrahi, Prasanta K.

    2017-11-01

    The notion of weak measurement in quantum mechanics has gained a significant and wide interest in realizing apparently counterintuitive quantum effects. In recent times, several theoretical and experimental works have been reported for demonstrating the joint weak value of two observables where the coupling strength is restricted to the second order. In this paper, we extend such a formulation by providing a complete treatment of joint weak measurement scenario for all-order-coupling for the observable satisfying A 2 = 𝕀 and A 2 = A, which allows us to reveal several hitherto unexplored features. By considering the probe state to be discrete as well as continuous variable, we demonstrate how the joint weak value can be inferred for any given strength of the coupling. A particularly interesting result we pointed out that even if the initial pointer state is uncorrelated, the single pointer displacement can provide the information about the joint weak value, if at least third order of the coupling is taken into account. As an application of our scheme, we provide an all-order-coupling treatment of the well-known Hardy paradox by considering the continuous as well as discrete meter states and show how the negative joint weak probabilities emerge in the quantum paradoxes at the weak coupling limit.

  19. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint

    PubMed Central

    Zhang, Xiangming

    2011-01-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint. PMID:21061141

  20. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    PubMed

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.