Sample records for keitel functional test

  1. Liver function tests

    MedlinePlus

    Liver function tests are common tests that are used to see how well the liver is working. Tests include: ... E, Bowne WB, Bluth MH. Evaluation of liver function. In: McPherson RA, Pincus MR, eds. Henry's Clinical ...

  2. Liver Function Tests

    MedlinePlus

    ... food, store energy, and remove poisons. Liver function tests are blood tests that check to see how well your liver ... hepatitis and cirrhosis. You may have liver function tests as part of a regular checkup. Or you ...

  3. Kidney function tests

    MedlinePlus

    Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...

  4. Functional Task Test (FTT)

    NASA Technical Reports Server (NTRS)

    Bloomberg, Jacob J.; Mulavara, Ajitkumar; Peters, Brian T.; Rescheke, Millard F.; Wood, Scott; Lawrence, Emily; Koffman, Igor; Ploutz-Snyder, Lori; Spiering, Barry A.; Feeback, Daniel L.; hide

    2009-01-01

    This slide presentation reviews the Functional Task Test (FTT), an interdisciplinary testing regimen that has been developed to evaluate astronaut postflight functional performance and related physiological changes. The objectives of the project are: (1) to develop a set of functional tasks that represent critical mission tasks for the Constellation Program, (2) determine the ability to perform these tasks after space flight, (3) Identify the key physiological factors that contribute to functional decrements and (4) Use this information to develop targeted countermeasures.

  5. Classical Testing in Functional Linear Models.

    PubMed

    Kong, Dehan; Staicu, Ana-Maria; Maity, Arnab

    2016-01-01

    We extend four tests common in classical regression - Wald, score, likelihood ratio and F tests - to functional linear regression, for testing the null hypothesis, that there is no association between a scalar response and a functional covariate. Using functional principal component analysis, we re-express the functional linear model as a standard linear model, where the effect of the functional covariate can be approximated by a finite linear combination of the functional principal component scores. In this setting, we consider application of the four traditional tests. The proposed testing procedures are investigated theoretically for densely observed functional covariates when the number of principal components diverges. Using the theoretical distribution of the tests under the alternative hypothesis, we develop a procedure for sample size calculation in the context of functional linear regression. The four tests are further compared numerically for both densely and sparsely observed noisy functional data in simulation experiments and using two real data applications.

  6. Classical Testing in Functional Linear Models

    PubMed Central

    Kong, Dehan; Staicu, Ana-Maria; Maity, Arnab

    2016-01-01

    We extend four tests common in classical regression - Wald, score, likelihood ratio and F tests - to functional linear regression, for testing the null hypothesis, that there is no association between a scalar response and a functional covariate. Using functional principal component analysis, we re-express the functional linear model as a standard linear model, where the effect of the functional covariate can be approximated by a finite linear combination of the functional principal component scores. In this setting, we consider application of the four traditional tests. The proposed testing procedures are investigated theoretically for densely observed functional covariates when the number of principal components diverges. Using the theoretical distribution of the tests under the alternative hypothesis, we develop a procedure for sample size calculation in the context of functional linear regression. The four tests are further compared numerically for both densely and sparsely observed noisy functional data in simulation experiments and using two real data applications. PMID:28955155

  7. 14 CFR 35.40 - Functional test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Functional test. 35.40 Section 35.40... STANDARDS: PROPELLERS Tests and Inspections § 35.40 Functional test. The variable-pitch propeller system must be subjected to the applicable functional tests of this section. The same propeller system used in...

  8. 14 CFR 35.40 - Functional test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Functional test. 35.40 Section 35.40... STANDARDS: PROPELLERS Tests and Inspections § 35.40 Functional test. The variable-pitch propeller system must be subjected to the applicable functional tests of this section. The same propeller system used in...

  9. 14 CFR 35.40 - Functional test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Functional test. 35.40 Section 35.40... STANDARDS: PROPELLERS Tests and Inspections § 35.40 Functional test. The variable-pitch propeller system must be subjected to the applicable functional tests of this section. The same propeller system used in...

  10. Track/train dynamics test procedure transfer function test

    NASA Technical Reports Server (NTRS)

    Vigil, R. A.

    1975-01-01

    A transfer function vibration test was made on an 80 ton open hopper freight car in an effort to obtain validation data on the car's nonlinear elastic model. Test configuration, handling, test facilities, test operations, and data acquisition/reduction activities necessary to meet the conditions of test requirements are given.

  11. 14 CFR 35.40 - Functional test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... representative engine on a test stand or on an airplane. The propeller must complete these tests without evidence... STANDARDS: PROPELLERS Tests and Inspections § 35.40 Functional test. The variable-pitch propeller system must be subjected to the applicable functional tests of this section. The same propeller system used in...

  12. 14 CFR 35.40 - Functional test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... representative engine on a test stand or on an airplane. The propeller must complete these tests without evidence... STANDARDS: PROPELLERS Tests and Inspections § 35.40 Functional test. The variable-pitch propeller system must be subjected to the applicable functional tests of this section. The same propeller system used in...

  13. Functional Task Test: 2. Spaceflight-Induced Cardiovascular Change and Recovery During NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Phillips, Tiffany; Arzeno, Natalia M.; Stenger, Michael; Lee, Stuart M. C.; Bloomberg, Jacob J.; Platts, Steven H.

    2011-01-01

    The overall objective of the functional task test (FTT) is to correlate spaceflight-induced physiological adaptations with changes in performance of high priority exploration mission-critical tasks. This presentation will focus on the recovery from fall/stand test (RFST), which measures the cardiovascular response to the transition from the prone posture (simulated fall) to standing in normal gravity, as well as heart rate (HR) during 11 functional tasks. As such, this test describes some aspects of spaceflight-induced cardiovascular deconditioning and the course of recovery in Space Shuttle and International Space Station (ISS) astronauts. The sensorimotor and neuromuscular components of the FTT are described in two separate abstracts: Functional Task Test 1 and 3.

  14. Liver Function Tests

    MedlinePlus

    ... Liver Function Tests Clinical Trials Liver Transplant FAQs Medical Terminology Diseases of the Liver Alagille Syndrome Alcohol-Related ... the Liver The Progression of Liver Disease FAQs Medical Terminology HOW YOU CAN HELP Sponsorship Ways to Give ...

  15. Track/train dynamics test report transfer function test. Volume 1: Test

    NASA Technical Reports Server (NTRS)

    Vigil, R. A.

    1975-01-01

    A description is presented of the transfer function test performed on an open hopper freight car loaded with 80 tons of coal. Test data and a post-test update of the requirements document and test procedure are presented. Included are a statement of the test objective, a description of the test configurations, test facilities, test methods, data acquisition/reduction operations, and a chronological test summary. An index to the data for the three test configurations (X, Y, and Z-axis tests) is presented along with test sequence, run number, test reference, and input parameters.

  16. Binomial test statistics using Psi functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, Kimiko o

    2007-01-01

    For the negative binomial model (probability generating function (p + 1 - pt){sup -k}) a logarithmic derivative is the Psi function difference {psi}(k + x) - {psi}(k); this and its derivatives lead to a test statistic to decide on the validity of a specified model. The test statistic uses a data base so there exists a comparison available between theory and application. Note that the test function is not dominated by outliers. Applications to (i) Fisher's tick data, (ii) accidents data, (iii) Weldon's dice data are included.

  17. Sweat testing to evaluate autonomic function

    PubMed Central

    Illigens, Ben M.W.; Gibbons, Christopher H.

    2011-01-01

    Sudomotor dysfunction is one of the earliest detectable neurophysiologic abnormalities in distal small fiber neuropathy. Traditional neurophysiologic measurements of sudomotor function include thermoregulatory sweat testing (TST), quantitative sudomotor axon reflex testing (QSART), silicone impressions, the sympathetic skin response (SSR), and the recent addition of quantitative direct and indirect axon reflex testing (QDIRT). These testing techniques, when used in combination, can detect and localized pre- and postganglionic lesions, can provide early diagnosis of sudomotor dysfunction and can monitor disease progression or disease recovery. In this article, we review the common tests available for assessment of sudomotor function, detail the testing methodology, review the limitations and provide examples of test results. PMID:18989618

  18. Functional performance testing for power and return to sports.

    PubMed

    Manske, Robert; Reiman, Michael

    2013-05-01

    Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete's activity. A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity.

  19. Functional Performance Testing for Power and Return to Sports

    PubMed Central

    Manske, Robert; Reiman, Michael

    2013-01-01

    Context: Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete’s activity. Evidence Acquisition: A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Conclusion: Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity. PMID:24427396

  20. Transfer of function and prior derived-relations testing.

    PubMed

    Doughty, Adam H; Best, Lauren

    2017-10-01

    This experiment assessed transfer of function through equivalence relations with and without prior derived-stimulus-relations (DSR) testing. In a DSR-Testing Group, eight college students learned A-B and A-C discriminations in baseline. They then derived the B-C and C-B equivalence relations before being exposed to a transfer-of-function manipulation and test. Eight participants in a No-DSR Testing Group were exposed to the transfer-of-function manipulation and test immediately after learning the baseline discriminations (i.e., B-C and C-B testing were omitted). In the transfer-of-function manipulation, participants learned to respond differently in the presence of B1 and B2 to avoid money loss. In the transfer-of-function test, responding in the presence of C1 and C2 was measured in the absence of differential consequences. Transfer of function occurred reliably only in the DSR-Testing Group (i.e., participants responding to C1 and C2 in the manner they learned to respond to B1 and B2, respectively). These findings support the notion that prior DSR testing can be critical to observing transfer of function. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The functional head impulse test: preliminary data.

    PubMed

    Corallo, Giulia; Versino, Maurizio; Mandalà, Marco; Colnaghi, Silvia; Ramat, Stefano

    2018-06-04

    The functional head impulse test is a new test of vestibular function based on the ability to recognize the orientation of a Landolt C optotype that briefly appears on a computer screen during passive head impulses imposed by the examiner over a range of head accelerations. Here, we compare its results with those of the video head impulse test on a population of vestibular neuritis patients recorded acutely and after 3 months from symptoms onset. The preliminary results presented here show that while both tests are able to identify the affected labyrinth and to show a recovery of vestibular functionality at 3 months, the two tests are not redundant, but complementary.

  2. Nonparametric tests for equality of psychometric functions.

    PubMed

    García-Pérez, Miguel A; Núñez-Antón, Vicente

    2017-12-07

    Many empirical studies measure psychometric functions (curves describing how observers' performance varies with stimulus magnitude) because these functions capture the effects of experimental conditions. To assess these effects, parametric curves are often fitted to the data and comparisons are carried out by testing for equality of mean parameter estimates across conditions. This approach is parametric and, thus, vulnerable to violations of the implied assumptions. Furthermore, testing for equality of means of parameters may be misleading: Psychometric functions may vary meaningfully across conditions on an observer-by-observer basis with no effect on the mean values of the estimated parameters. Alternative approaches to assess equality of psychometric functions per se are thus needed. This paper compares three nonparametric tests that are applicable in all situations of interest: The existing generalized Mantel-Haenszel test, a generalization of the Berry-Mielke test that was developed here, and a split variant of the generalized Mantel-Haenszel test also developed here. Their statistical properties (accuracy and power) are studied via simulation and the results show that all tests are indistinguishable as to accuracy but they differ non-uniformly as to power. Empirical use of the tests is illustrated via analyses of published data sets and practical recommendations are given. The computer code in MATLAB and R to conduct these tests is available as Electronic Supplemental Material.

  3. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    PubMed

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  4. Simple Test Functions in Meshless Local Petrov-Galerkin Methods

    NASA Technical Reports Server (NTRS)

    Raju, Ivatury S.

    2016-01-01

    Two meshless local Petrov-Galerkin (MLPG) methods based on two different trial functions but that use a simple linear test function were developed for beam and column problems. These methods used generalized moving least squares (GMLS) and radial basis (RB) interpolation functions as trial functions. These two methods were tested on various patch test problems. Both methods passed the patch tests successfully. Then the methods were applied to various beam vibration problems and problems involving Euler and Beck's columns. Both methods yielded accurate solutions for all problems studied. The simple linear test function offers considerable savings in computing efforts as the domain integrals involved in the weak form are avoided. The two methods based on this simple linear test function method produced accurate results for frequencies and buckling loads. Of the two methods studied, the method with radial basis trial functions is very attractive as the method is simple, accurate, and robust.

  5. Platelet Function Tests: Preanalytical Variables, Clinical Utility, Advantages, and Disadvantages.

    PubMed

    Hvas, Anne-Mette; Grove, Erik Lerkevang

    2017-01-01

    Platelet function tests are mainly used in the diagnostic work-up of platelet disorders. During the last decade, the additional use of platelet function tests to evaluate the effect of antiplatelet therapy has also emerged in an attempt to identify patients with an increased risk of arterial thrombosis. Furthermore, platelet function tests are increasingly used to measure residual effect of antiplatelet therapy prior to surgery with the aim of reducing the risk of bleeding. To a limited extend, platelet function tests are also used to evaluate hyperaggregability as a potential marker of a prothrombotic state outside the setting of antiplatelet therapy. This multifaceted use of platelet function tests and the development of simpler point-of-care tests with narrower application have increased the use of platelet function testing and also facilitated the use of platelet function tests outside the highly specialized laboratories. The present chapter describes the preanalytical variables, which should be taken into account when planning platelet function testing. Also, the most widely used platelet function tests are introduced, and their clinical utility and their relative advantages and disadvantages are discussed.

  6. HEALTH SIGNIFICANCE OF PULMONARY FUNCTION TESTS

    EPA Science Inventory

    As the sensitivity and precision of functional tests improves, we become increasingly able to measure responses to pollutant exposures with little, if any, demonstrable health significance. Proper interpretation of such functional responses generally requires an ability to evalua...

  7. Indications and interpretation of esophageal function testing.

    PubMed

    Gyawali, C Prakash; de Bortoli, Nicola; Clarke, John; Marinelli, Carla; Tolone, Salvatore; Roman, Sabine; Savarino, Edoardo

    2018-05-12

    Esophageal symptoms are common, and can arise from mucosal, motor, functional, and neoplastic processes, among others. Judicious use of diagnostic testing can help define the etiology of symptoms and can direct management. Endoscopy, esophageal high-resolution manometry (HRM), ambulatory pH or pH-impedance manometry, and barium radiography are commonly used for esophageal function testing; functional lumen imaging probe is an emerging option. Recent consensus guidelines have provided direction in using test findings toward defining mechanisms of esophageal symptoms. The Chicago Classification describes hierarchical steps in diagnosing esophageal motility disorders. The Lyon Consensus characterizes conclusive evidence on esophageal testing for a diagnosis of gastroesophageal reflux disease (GERD), and establishes a motor classification of GERD. Taking these recent advances into consideration, our discussion focuses primarily on the indications, technique, equipment, and interpretation of esophageal HRM and ambulatory reflux monitoring in the evaluation of esophageal symptoms, and describes indications for alternative esophageal tests. © 2018 New York Academy of Sciences.

  8. The Functional Task Test (FTT): An Interdisciplinary Testing Protocol to Investigate the Factors Underlying Changes in Astronaut Functional Performance

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Lawrence, E. L.; Arzeno, N. M.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts. S. H.; hide

    2011-01-01

    Exposure to space flight causes adaptations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. To achieve this goal we developed an interdisciplinary testing protocol (Functional Task Test, FTT) that evaluates both astronaut functional performance and related physiological changes. Functional tests include ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall and object translation tasks. Physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper- and lower-body muscle strength, power, endurance, control, and neuromuscular drive. Crewmembers perform this integrated test protocol before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on two sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Preliminary results from both Shuttle and ISS crewmembers indicate decrement in performance of the functional tasks after both short and long-duration space flight. On-going data collection continues to improve the statistical power required to map changes in functional task performance to alterations in physiological systems. The information obtained from this study will be used to design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

  9. Reference values of renal tubular function tests are dependent on age and kidney function.

    PubMed

    Bech, Anneke P; Wetzels, Jack F M; Nijenhuis, Tom

    2017-12-01

    Electrolyte disorders due to tubular disorders are rare, and knowledge about validated clinical diagnostic tools such as tubular function tests is sparse. Reference values for tubular function tests are based on studies with small sample size in young healthy volunteers. Patients with tubular disorders, however, frequently are older and can have a compromised renal function. We therefore evaluated four tubular function tests in individuals with different ages and renal function. We performed furosemide, thiazide, furosemide-fludrocortisone, and desmopressin tests in healthy individuals aged 18-50 years, healthy individuals aged more than 50 years and individuals with compromised renal function. For each tubular function test we included 10 individuals per group. The responses in young healthy individuals were in line with previously reported values in literature. The maximal increase in fractional chloride excretion after furosemide was below the lower limit of young healthy individuals in 5/10 older subjects and in 2/10 patients with compromised renal function. The maximal increase in fractional chloride excretion after thiazide was below the lower limit of young healthy individuals in 6/10 older subjects and in 7/10 patients with compromised renal function. Median maximal urine osmolality after desmopressin was 1002 mosmol/kg H 2 O in young healthy individuals, 820 mosmol/kg H 2 O in older subjects and 624 mosmol/kg H 2 O in patients with compromised renal function. Reference values for tubular function tests obtained in young healthy adults thus cannot simply be extrapolated to older patients or patients with compromised kidney function. Larger validation studies are needed to define true reference values in these patient categories. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  10. Functional Performance Testing After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Abrams, Geoffrey D.; Harris, Joshua D.; Gupta, Anil K.; McCormick, Frank M.; Bush-Joseph, Charles A.; Verma, Nikhil N.; Cole, Brian J.; Bach, Bernard R.

    2014-01-01

    Background: When to allow an athlete to return to unrestricted sporting activity after anterior cruciate ligament (ACL) reconstruction remains controversial. Purpose: To report the results of functional performance testing reported in the literature for individuals at differing time points following ACL reconstruction and to examine differences between graft types. Study Design: Systematic review; Level of evidence, 4. Methods: A systematic review of Medline, Scopus, and Cochrane Central Register of Controlled Trials was performed using PRISMA guidelines. Inclusion criteria were English-language studies that examined any functional rehabilitation test from 6 months to 2 years following ACL reconstruction. All patient-, limb-, and knee-specific demographics were extracted from included investigations. All functional rehabilitation tests were analyzed and compared when applicable. Results: The search term returned a total of 890 potential studies, with 88 meeting inclusion and exclusion criteria. A total of 4927 patients were included, of which 66% were male. The mean patient age was 26.5 ± 3.4 years. The predominant graft choices for reconstruction were bone–patellar tendon–bone (BPTB) autograft (59.8%) and hamstring autograft (37.9%). The most commonly reported functional tests were the hop tests. The results of these functional tests, as reported in the Limb Symmetry Index (LSI), improved with increasing time, with nearly all results greater than 90% at 1 year following primary ACL reconstruction. At 6 months postoperatively, a number of isokinetic strength measurements failed to reach 80% LSI, most commonly isokinetic knee extension testing in both BPTB and hamstring autograft groups. The knee flexion strength deficit was significantly less in the BPTB autograft group as compared with those having hamstring autograft at 1 year postoperatively, while no significant differences were found in isokinetic extension strength between the 2 groups. Conclusion: Hop

  11. Functional and nonfunctional testing of ATM networks

    NASA Astrophysics Data System (ADS)

    Ricardo, Manuel; Ferreira, M. E. P.; Guimaraes, Francisco E.; Mamede, J.; Henriques, M.; da Silva, Jorge A.; Carrapatoso, E.

    1995-02-01

    ATM network will support new multimedia services that will require new protocols, those services and protocols will need different test strategies and tools. In this paper, the concepts of functional and non-functional testers of ATM networks are discussed, a multimedia service and its requirements are presented and finally, a summary description of an ATM network and of the test tool that will be used to validate it are presented.

  12. Reducing measurement errors during functional capacity tests in elders.

    PubMed

    da Silva, Mariane Eichendorf; Orssatto, Lucas Bet da Rosa; Bezerra, Ewertton de Souza; Silva, Diego Augusto Santos; Moura, Bruno Monteiro de; Diefenthaeler, Fernando; Freitas, Cíntia de la Rocha

    2018-06-01

    Accuracy is essential to the validity of functional capacity measurements. To evaluate the error of measurement of functional capacity tests for elders and suggest the use of the technical error of measurement and credibility coefficient. Twenty elders (65.8 ± 4.5 years) completed six functional capacity tests that were simultaneously filmed and timed by four evaluators by means of a chronometer. A fifth evaluator timed the tests by analyzing the videos (reference data). The means of most evaluators for most tests were different from the reference (p < 0.05), except for two evaluators for two different tests. There were different technical error of measurement between tests and evaluators. The Bland-Altman test showed difference in the concordance of the results between methods. Short duration tests showed higher technical error of measurement than longer tests. In summary, tests timed by a chronometer underestimate the real results of the functional capacity. Difference between evaluators' reaction time and perception to determine the start and the end of the tests would justify the errors of measurement. Calculation of the technical error of measurement or the use of the camera can increase data validity.

  13. Evaluation of abnormal liver function tests.

    PubMed

    Agrawal, Swastik; Dhiman, Radha K; Limdi, Jimmy K

    2016-04-01

    Incidentally detected abnormality in liver function tests is a common situation encountered by physicians across all disciplines. Many of these patients do not have primary liver disease as most of the commonly performed markers are not specific for the liver and are affected by myriad factors unrelated to liver disease. Also, many of these tests like liver enzyme levels do not measure the function of the liver, but are markers of liver injury, which is broadly of two types: hepatocellular and cholestatic. A combination of a careful history and clinical examination along with interpretation of pattern of liver test abnormalities can often identify type and aetiology of liver disease, allowing for a targeted investigation approach. Severity of liver injury is best assessed by composite scores like the Model for End Stage Liver Disease rather than any single parameter. In this review, we discuss the interpretation of the routinely performed liver tests along with the indications and utility of quantitative tests. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. [Tests of hand functionality in upper limb amputation with prosthesis].

    PubMed

    Bazzini, G; Orlandini, D; Moscato, T A; Nicita, D; Panigazzi, M

    2007-01-01

    The need for standardized instruments for clinical measurements has become pressing in the fields of occupational rehabilitation and ergonomics. This is particularly the case for instruments that allow a quantitative evaluation of upper limb function, and especially hand function in patients who have undergone an amputation and then application of an upper limb prosthesis. This study presents a review of the main tests used to evaluate hand function, with a critical analysis of their use in subjects with an upper limb prosthesis. The tests are divided into: tests to evaluate strength, tests to evaluate co-ordination and dexterity, tests of global or overall function, and tests proposed specifically for subjects with an upper limb prosthesis. Of the various tests presented, the authors give their preference to the Bimanual Functional Assessment, Abilhand and/or the ADL Questionnaire, because of the practical usefulness, clinimetric features, simplicity and ease of administration of these tests.

  15. Significance tests for functional data with complex dependence structure.

    PubMed

    Staicu, Ana-Maria; Lahiri, Soumen N; Carroll, Raymond J

    2015-01-01

    We propose an L 2 -norm based global testing procedure for the null hypothesis that multiple group mean functions are equal, for functional data with complex dependence structure. Specifically, we consider the setting of functional data with a multilevel structure of the form groups-clusters or subjects-units, where the unit-level profiles are spatially correlated within the cluster, and the cluster-level data are independent. Orthogonal series expansions are used to approximate the group mean functions and the test statistic is estimated using the basis coefficients. The asymptotic null distribution of the test statistic is developed, under mild regularity conditions. To our knowledge this is the first work that studies hypothesis testing, when data have such complex multilevel functional and spatial structure. Two small-sample alternatives, including a novel block bootstrap for functional data, are proposed, and their performance is examined in simulation studies. The paper concludes with an illustration of a motivating experiment.

  16. Esophageal function testing: Billing and coding update.

    PubMed

    Khan, A; Massey, B; Rao, S; Pandolfino, J

    2018-01-01

    Esophageal function testing is being increasingly utilized in diagnosis and management of esophageal disorders. There have been several recent technological advances in the field to allow practitioners the ability to more accurately assess and treat such conditions, but there has been a relative lack of education in the literature regarding the associated Common Procedural Terminology (CPT) codes and methods of reimbursement. This review, commissioned and supported by the American Neurogastroenterology and Motility Society Council, aims to summarize each of the CPT codes for esophageal function testing and show the trends of associated reimbursement, as well as recommend coding methods in a practical context. We also aim to encourage many of these codes to be reviewed on a gastrointestinal (GI) societal level, by providing evidence of both discrepancies in coding definitions and inadequate reimbursement in this new era of esophageal function testing. © 2017 John Wiley & Sons Ltd.

  17. Do functional tests predict low back pain?

    PubMed

    Takala, E P; Viikari-Juntura, E

    2000-08-15

    A cohort of 307 nonsymptomatic workers and another cohort of 123 workers with previous episodes of low back pain were followed up for 2 years. The outcomes were measured by symptoms, medical consultations, and sick leaves due to low back disorders. To study the predictive value of a set of tests measuring the physical performance of the back in a working population. The hypothesis was that subjects with poor functional capacity are liable to back disorders. Reduced functional performance has been associated with back pain. There are few data to show whether reduced functional capacity is a cause or a consequence of pain. Mobility of the trunk in forward and side bending, maximal isokinetic trunk extension, flexion and lifting strength, and static endurance of back extension were measured. Standing balance and foot reaction time were recorded with a force plate. Clinical tests for the provocation of back or leg pain were performed. Gender, workload, age, and anthropometrics were managed as potential confounders in the analysis. Marked overlapping was seen in the measures of the subjects with different outcomes. Among the nonsymptomatic subjects, low performance in tests of mobility and standing balance was associated with future back disorders. Among workers with previous episodes of back pain, low isokinetic extension strength, poor standing balance, and positive clinical signs predicted future pain. Some associations were found between the functional tests and future low back pain. The wide variation in the results questions the value of the tests in health examinations (e.g., in screening or surveillance of low back disorders).

  18. GALACSI integration and functional tests

    NASA Astrophysics Data System (ADS)

    La Penna, P.; Ströbele, S.; Aller Carpentier, E.; Argomedo, J.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Donaldson, R.; Duchateau, M.; Fedrigo, E.; Gago, F.; Hubin, N.; Quentin, J.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J. L.; Madec, P.-.; Manescau, A.; Mehrgan, L.; Sedghi, B.; Suarez Valles, M.; Soenke, C.; Tordo, S.; Vernet, J.; Zampieri, S.

    2014-07-01

    GALACSI is the Adaptive Optics (AO) modules of the ESO Adaptive Optics Facility (AOF) that will correct the wavefront delivered to the MUSE Integral Field Spectrograph. It will sense with four 40×40 subapertures Shack-Hartmann wavefront sensors the AOF 4 Laser Guide Stars (LGS), acting on the 1170 voice-coils actuators of the Deformable Secondary Mirror (DSM). GALACSI has two operating modes: in Wide Field Mode (WFM), with the four LGS at 64" off axis, the collected energy in a 0.2"×0.2" pixel will be enhanced by a factor 2 at 750 nm over a Field of View (FoV) of 1'×1' using the Ground Layer AO (GLAO) technique. The other mode, the Narrow Field Mode (NFM), provides an enhanced wavefront correction (Strehl Ratio (SR) of 5% (goal 10%) at 650 nm) but in a smaller FoV (7.5"×7.5"), using Laser Tomography AO (LTAO), with the 4 LGS located closer, at 10" off axis. Before being shipped to Paranal, GALACSI will be first integrated and fully tested in stand-alone, and then moved to a dedicated AOF facility to be tested with the DSM in Europe. At present the module is fully assembled, its main functionalities have been implemented and verified, and AO system tests with the DSM are starting. We present here the main system features and the results of the internal functional tests of GALACSI.

  19. Physiological and biochemical basis of clinical liver function tests: a review.

    PubMed

    Hoekstra, Lisette T; de Graaf, Wilmar; Nibourg, Geert A A; Heger, Michal; Bennink, Roelof J; Stieger, Bruno; van Gulik, Thomas M

    2013-01-01

    To review the literature on the most clinically relevant and novel liver function tests used for the assessment of hepatic function before liver surgery. Postoperative liver failure is the major cause of mortality and morbidity after partial liver resection and develops as a result of insufficient remnant liver function. Therefore, accurate preoperative assessment of the future remnant liver function is mandatory in the selection of candidates for safe partial liver resection. A MEDLINE search was performed using the key words "liver function tests," "functional studies in the liver," "compromised liver," "physiological basis," and "mechanistic background," with and without Boolean operators. Passive liver function tests, including biochemical parameters and clinical grading systems, are not accurate enough in predicting outcome after liver surgery. Dynamic quantitative liver function tests, such as the indocyanine green test and galactose elimination capacity, are more accurate as they measure the elimination process of a substance that is cleared and/or metabolized almost exclusively by the liver. However, these tests only measure global liver function. Nuclear imaging techniques ((99m)Tc-galactosyl serum albumin scintigraphy and (99m)Tc-mebrofenin hepatobiliary scintigraphy) can measure both total and future remnant liver function and potentially identify patients at risk for postresectional liver failure. Because of the complexity of liver function, one single test does not represent overall liver function. In addition to computed tomography volumetry, quantitative liver function tests should be used to determine whether a safe resection can be performed. Presently, (99m)Tc-mebrofenin hepatobiliary scintigraphy seems to be the most valuable quantitative liver function test, as it can measure multiple aspects of liver function in, specifically, the future remnant liver.

  20. TRL - A FORMAL TEST REPRESENTATION LANGUAGE AND TOOL FOR FUNCTIONAL TEST DESIGNS

    NASA Technical Reports Server (NTRS)

    Hops, J. M.

    1994-01-01

    A Formal Test Representation Language and Tool for Functional Test Designs (TRL) is an automatic tool and a formal language that is used to implement the Category-Partition Method and produce the specification of test cases in the testing phase of software development. The Category-Partition Method is particularly useful in defining the inputs, outputs and purpose of the test design phase and combines the benefits of choosing normal cases with error exposing properties. Traceability can be maintained quite easily by creating a test design for each objective in the test plan. The effort to transform the test cases into procedures is simplified by using an automatic tool to create the cases based on the test design. The method allows the rapid elimination of undesired test cases from consideration, and easy review of test designs by peer groups. The first step in the category-partition method is functional decomposition, in which the specification and/or requirements are decomposed into functional units that can be tested independently. A secondary purpose of this step is to identify the parameters that affect the behavior of the system for each functional unit. The second step, category analysis, carries the work done in the previous step further by determining the properties or sub-properties of the parameters that would make the system behave in different ways. The designer should analyze the requirements to determine the features or categories of each parameter and how the system may behave if the category were to vary its value. If the parameter undergoing refinement is a data-item, then categories of this data-item may be any of its attributes, such as type, size, value, units, frequency of change, or source. After all the categories for the parameters of the functional unit have been determined, the next step is to partition each category's range space into mutually exclusive values that the category can assume. In choosing partition values, all possible kinds

  1. An Efficient Functional Test Generation Method For Processors Using Genetic Algorithms

    NASA Astrophysics Data System (ADS)

    Hudec, Ján; Gramatová, Elena

    2015-07-01

    The paper presents a new functional test generation method for processors testing based on genetic algorithms and evolutionary strategies. The tests are generated over an instruction set architecture and a processor description. Such functional tests belong to the software-oriented testing. Quality of the tests is evaluated by code coverage of the processor description using simulation. The presented test generation method uses VHDL models of processors and the professional simulator ModelSim. The rules, parameters and fitness functions were defined for various genetic algorithms used in automatic test generation. Functionality and effectiveness were evaluated using the RISC type processor DP32.

  2. First State Fitness Test. A Measurement of Functional Health.

    ERIC Educational Resources Information Center

    Brown, Timothy; And Others

    This test is designed to measure the functional health of young people. Functional health refers to those factors relating to personal health that can be improved with regular exercise. This test is unique in comparison to other physical fitness tests because of the absence of motor skill items which have no relationship to an individual's…

  3. MUSCULOSKELETAL SCREENING AND FUNCTIONAL TESTING: CONSIDERATIONS FOR BASKETBALL ATHLETES.

    PubMed

    Bird, Stephen P; Markwick, William J

    2016-10-01

    Youth participation in basketball is on the rise, with basketball one of the top five participation sports in Australia. With increased participation there is a need for greater awareness of the importance of the pre-participation examination, including musculoskeletal screening and functional performance testing as part of a multidisciplinary approach to reducing the risk for future injuries. As majority of all basketball injuries affect the lower extremities, pre-participation musculoskeletal screening and functional performance testing should assess fundamental movement qualities throughout the kinetic chain with an emphasis on lower extremity force characteristics, specifically eccentric loading tasks. Thus, the purpose of this clinical commentary is to review the existing literature elucidating pre-participation musculoskeletal screening and functional performance tests that can be used as a framework for rehabilitation professionals in assessing basketball athletes' readiness to safely perform the movement demands of their sport. Relevant articles published between 2000 and 2016 using the search terms 'musculoskeletal screening', 'functional testing', 'youth athletes', and 'basketball' were identified using MEDLINE. From a basketball-specific perspective, several relevant musculoskeletal assessments were identified, including: the Functional Hop Test Combination, the Landing Error Scoring System, the Tuck Jump Assessment, the Weight-Bearing Lunge Test, and the Star Excursion Balance Test. Each of these assessments creates movement demands that allow for easy identification of inefficient and/or compensatory movement tendencies. A basic understanding of musculoskeletal deficits including bilateral strength and flexibility imbalances, lower crossed syndrome, and dominance-related factors are key components in determination of injury risk. Assessment of sport-specific movement demands through musculoskeletal screening and functional performance testing is

  4. Non-invasive pulmonary function test on Morquio Patients

    PubMed Central

    Kubaski, Francyne; Tomatsu, Shunji; Patel, Pravin; Shimada, Tsutomu; Xie, Li; Yasuda, Eriko; Mason, Robert; Mackenzie, William G.; Theroux, Mary; Bober, Michael B.; Oldham, Helen M.; Orii, Tadao; Shaffer, Thomas H.

    2015-01-01

    In clinical practice, respiratory function tests are difficult to perform in Morquio syndrome patients due to their characteristic skeletal dysplasia, small body size and lack of cooperation of young patients, where in some cases, conventional spirometry for pulmonary function is too challenging. To establish feasible clinical pulmonary endpoints and determine whether age impacts lung function in Morquio patients non-invasive pulmonary tests and conventional spirometry were evaluated. The non-invasive pulmonary tests: impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography in conjunction with conventional spirometry were evaluated in twenty-two Morquio patients (18 Morquio A and 4 Morquio B) (7 males), ranging from 3 and 40 years of age. Twenty-two patients were compliant with non-invasive tests (100%) with exception of IOS (81.8%–18 patients). Seventeen patients (77.3%) were compliant with spirometry testing. All subjects had normal vital signs at rest including > 95% oxygen saturation, end tidal CO2 (38–44 mmHg), and age-appropriate heart rate (mean=98.3, standard deviation=19) (two patients were deviated). All patients preserved normal values in impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography, although predicted forced expiratory volume total (72.8 ± 6.9 SE%) decreased with age and was below normal; phase angle (35.5 ± 16.5 Degrees), %Rib Cage (41.6 ± 12.7%), resonant frequency, and forced expiratory volume in one second/forced expiratory volume total (110.0 ± 3.2 SE%) were normal and not significantly impacted by age. The proposed non-invasive pulmonary function tests are able to cover a greater number of patients (young patients and/or wheel-chair bound), thus providing a new diagnostic approach for the assessment of lung function in Morquio syndrome which in many cases may be difficult to evaluate. Morquio patients studied herein demonstrated no clinical or functional signs

  5. Note: The full function test explosive generator.

    PubMed

    Reisman, D B; Javedani, J B; Griffith, L V; Ellsworth, G F; Kuklo, R M; Goerz, D A; White, A D; Tallerico, L J; Gidding, D A; Murphy, M J; Chase, J B

    2010-03-01

    We have conducted three tests of a new pulsed power device called the full function test. These tests represented the culmination of an effort to establish a high energy pulsed power capability based on high explosive pulsed power (HEPP) technology. This involved an extensive computational modeling, engineering, fabrication, and fielding effort. The experiments were highly successful and a new U.S. record for magnetic energy was obtained.

  6. The Unknown Generals - German Corps Commanders in World War 2.

    DTIC Science & Technology

    1988-06-03

    Rudolf Schnundt: 1.10.42-29.10.44. (Daily Reports of *the Chief of the Army Personnel Office General of Infantry Rudolf Sch undt: October 1, 1942 to...loan. i German officer efficiency reports are discussed by Rudolf S.Hofmann in "German Efficiency Report System" another Historical Division study. The...General der Infanterie Rudolf Schmundt, and General der Infanterie Wilhelm Burgdorf were three of these men. 63 Wilhelm Keitel served as Chief of Staff

  7. Biologic variability and correlation of platelet function testing in healthy dogs.

    PubMed

    Blois, Shauna L; Lang, Sean T; Wood, R Darren; Monteith, Gabrielle

    2015-12-01

    Platelet function tests are influenced by biologic variability, including inter-individual (CVG ) and intra-individual (CVI ), as well as analytic (CVA ) variability. Variability in canine platelet function testing is unknown, but if excessive, would make it difficult to interpret serial results. Additionally, the correlation between platelet function tests is poor in people, but not well described in dogs. The aims were to: (1) identify the effect of variation in preanalytic factors (venipuncture, elapsed time until analysis) on platelet function tests; (2) calculate analytic and biologic variability of adenosine diphosphate (ADP) and arachidonic acid (AA)-induced thromboelastograph platelet mapping (TEG-PM), ADP-, AA-, and collagen-induced whole blood platelet aggregometry (WBA), and collagen/ADP and collagen/epinephrine platelet function analysis (PFA-CADP, PFA-CEPI); and (3) determine the correlation between these variables. In this prospective observational trial, platelet function was measured once every 7 days, for 4 consecutive weeks, in 9 healthy dogs. In addition, CBC, TEG-PM, WBA, and PFA were performed. Overall coefficients of variability ranged from 13.3% to 87.8% for the platelet function tests. Biologic variability was highest for AA-induced maximum amplitude generated during TEG-PM (MAAA; CVG = 95.3%, CVI = 60.8%). Use of population-based reference intervals (RI) was determined appropriate only for PFA-CADP (index of individuality = 10.7). There was poor correlation between most platelet function tests. Use of population-based RI appears inappropriate for most platelet function tests, and tests poorly correlate with one another. Future studies on biologic variability and correlation of platelet function tests should be performed in dogs with platelet dysfunction and those treated with antiplatelet therapy. © 2015 American Society for Veterinary Clinical Pathology.

  8. A Generalized DIF Effect Variance Estimator for Measuring Unsigned Differential Test Functioning in Mixed Format Tests

    ERIC Educational Resources Information Center

    Penfield, Randall D.; Algina, James

    2006-01-01

    One approach to measuring unsigned differential test functioning is to estimate the variance of the differential item functioning (DIF) effect across the items of the test. This article proposes two estimators of the DIF effect variance for tests containing dichotomous and polytomous items. The proposed estimators are direct extensions of the…

  9. 33 CFR 157.12f - Workshop functional test requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements. (a) Each oil content meter and each control section of a monitoring system must be subjected to a... protocol must be received with each unit delivered. (b) A functional test conducted on an oil content meter...

  10. 33 CFR 157.12f - Workshop functional test requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements. (a) Each oil content meter and each control section of a monitoring system must be subjected to a... protocol must be received with each unit delivered. (b) A functional test conducted on an oil content meter...

  11. 33 CFR 157.12f - Workshop functional test requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements. (a) Each oil content meter and each control section of a monitoring system must be subjected to a... protocol must be received with each unit delivered. (b) A functional test conducted on an oil content meter...

  12. Distinguishing transient signals and instrumental disturbances in semi-coherent searches for continuous gravitational waves with line-robust statistics

    NASA Astrophysics Data System (ADS)

    Keitel, David

    2016-05-01

    Non-axisymmetries in rotating neutron stars emit quasi-monochromatic gravitational waves. These long-duration ‘continuous wave’ signals are among the main search targets of ground-based interferometric detectors. However, standard detection methods are susceptible to false alarms from instrumental artefacts that resemble a continuous-wave signal. Past work [Keitel, Prix, Papa, Leaci and Siddiqi 2014, Phys. Rev. D 89 064023] showed that a Bayesian approach, based on an explicit model of persistent single-detector disturbances, improves robustness against such artefacts. Since many strong outliers in semi-coherent searches of LIGO data are caused by transient disturbances that last only a few hours or days, I describe in a recent paper [Keitel D 2015, LIGO-P1500159] how to extend this approach to cover transient disturbances, and demonstrate increased sensitivity in realistic simulated data. Additionally, neutron stars could emit transient signals which, for a limited time, also follow the continuous-wave signal model. As a pragmatic alternative to specialized transient searches, I demonstrate how to make standard semi-coherent continuous-wave searches more sensitive to transient signals. Focusing on the time-scale of a single segment in the semi-coherent search, Bayesian model selection yields a simple detection statistic without a significant increase in computational cost. This proceedings contribution gives a brief overview of both works.

  13. Executive function on the Psychology Experiment Building Language tests.

    PubMed

    Piper, Brian J; Li, Victoria; Eiwaz, Massarra A; Kobel, Yuliyana V; Benice, Ted S; Chu, Alex M; Olsen, Reid H J; Rice, Douglas Z; Gray, Hilary M; Mueller, Shane T; Raber, Jacob

    2012-03-01

    The measurement of executive function has a long history in clinical and experimental neuropsychology. The goal of the present report was to determine the profile of behavior across the lifespan on four computerized measures of executive function contained in the recently developed Psychology Experiment Building Language (PEBL) test battery http://pebl.sourceforge.net/ and evaluate whether this pattern is comparable to data previously obtained with the non-PEBL versions of these tests. Participants (N = 1,223; ages, 5-89 years) completed the PEBL Trail Making Test (pTMT), the Wisconsin Card Sort Test (pWCST; Berg, Journal of General Psychology, 39, 15-22, 1948; Grant & Berg, Journal of Experimental Psychology, 38, 404-411, 1948), the Tower of London (pToL), or a time estimation task (Time-Wall). Age-related effects were found over all four tests, especially as age increased from young childhood through adulthood. For several tests and measures (including pToL and pTMT), age-related slowing was found as age increased in adulthood. Together, these findings indicate that the PEBL tests provide valid and versatile new research tools for measuring executive functions.

  14. Liver function testing with nuclear medicine techniques is coming of age.

    PubMed

    Bennink, Roelof J; Tulchinsky, Mark; de Graaf, Wilmar; Kadry, Zakiyah; van Gulik, Thomas M

    2012-03-01

    Liver function is a broad term, as the organ participates in a multitude of different physiological and biochemical processes, including metabolic, synthetic, and detoxifying functions. However, it is the function of the hepatocyte that is central to sustaining normal life and dealing with disease states. When the liver begins to fail in severely ill patients, it forecasts a terminal outcome. However, unlike the glomerular filtration rate which clearly quantifies the key renal function, at most practice sites, there is no clinically available quantitative test for liver function. Although it is commonplace to assess indirect evidence of that function (by measuring blood levels of its end products and by-products) and to detect an acute injury (by following rising transaminases), a widely available test that would directly measure hepatocellular function is lacking. This article reviews current knowledge on liver function studies and focuses on those nuclear medicine tests available to study the whole liver and regional liver function. The clinical application driving these tests, prediction of remnant liver function after partial hepatectomy for primary liver malignancy or metastatic disease, is addressed here in detail. The test was recently validated for this specific application and was shown to be better than the current standard of practice (computed tomography volumetry), particularly in patients with hepatic comorbidities like cirrhosis, steatosis, or cholestasis. Furthermore, early assessment of regional liver function increase after preoperative portal vein embolization becomes possible with this technology. The limiting factor to a wider acceptance of this test is based on the lack of clinical software that would allow calculation of liver function parameters. This article provides information that enables a clinical nuclear medicine facility to provide this test using readily available equipment. Furthermore, it addresses emerging clinical applications

  15. MUSCULOSKELETAL SCREENING AND FUNCTIONAL TESTING: CONSIDERATIONS FOR BASKETBALL ATHLETES

    PubMed Central

    Markwick, William J.

    2016-01-01

    Background and Purpose Youth participation in basketball is on the rise, with basketball one of the top five participation sports in Australia. With increased participation there is a need for greater awareness of the importance of the pre-participation examination, including musculoskeletal screening and functional performance testing as part of a multidisciplinary approach to reducing the risk for future injuries. As majority of all basketball injuries affect the lower extremities, pre-participation musculoskeletal screening and functional performance testing should assess fundamental movement qualities throughout the kinetic chain with an emphasis on lower extremity force characteristics, specifically eccentric loading tasks. Thus, the purpose of this clinical commentary is to review the existing literature elucidating pre-participation musculoskeletal screening and functional performance tests that can be used as a framework for rehabilitation professionals in assessing basketball athletes’ readiness to safely perform the movement demands of their sport. Methods Relevant articles published between 2000 and 2016 using the search terms ‘musculoskeletal screening’, ‘functional testing’, ‘youth athletes’, and ‘basketball’ were identified using MEDLINE. From a basketball-specific perspective, several relevant musculoskeletal assessments were identified, including: the Functional Hop Test Combination, the Landing Error Scoring System, the Tuck Jump Assessment, the Weight-Bearing Lunge Test, and the Star Excursion Balance Test. Each of these assessments creates movement demands that allow for easy identification of inefficient and/or compensatory movement tendencies. A basic understanding of musculoskeletal deficits including bilateral strength and flexibility imbalances, lower crossed syndrome, and dominance-related factors are key components in determination of injury risk. Discussion Assessment of sport-specific movement demands through

  16. Tests for the extraction of Boer-Mulders functions

    NASA Astrophysics Data System (ADS)

    Christova, Ekaterina; Leader, Elliot; Stoilov, Michail

    2017-12-01

    At present, the Boer-Mulders (BM) functions are extracted from asymmetry data using the simplifying assumption of their proportionality to the Sivers functions for each quark flavour. Here we present two independent tests for this assumption. We subject COMPASS data on semi-inclusive deep inelastic scattering on the 〈cos ϕh 〉, 〈cos 2ϕh 〉 and Sivers asymmetries to these tests. Our analysis shows that the tests are satisfied with the available data if the proportionality constant is the same for all quark flavours, which does not correspond to the flavour dependence used in existing analyses. This suggests that the published information on the BM functions may be unreliable. The 〈cos ϕh 〉, 〈cos 2ϕh 〉 asymmetries receive contributions also from the, in principle, calculable Cahn effect. We succeed in extracting the Cahn contributions from experiment (we believe for the first time) and compare with their calculated values, with interesting implications.

  17. A Powerful Test for Comparing Multiple Regression Functions.

    PubMed

    Maity, Arnab

    2012-09-01

    In this article, we address the important problem of comparison of two or more population regression functions. Recently, Pardo-Fernández, Van Keilegom and González-Manteiga (2007) developed test statistics for simple nonparametric regression models: Y(ij) = θ(j)(Z(ij)) + σ(j)(Z(ij))∊(ij), based on empirical distributions of the errors in each population j = 1, … , J. In this paper, we propose a test for equality of the θ(j)(·) based on the concept of generalized likelihood ratio type statistics. We also generalize our test for other nonparametric regression setups, e.g, nonparametric logistic regression, where the loglikelihood for population j is any general smooth function [Formula: see text]. We describe a resampling procedure to obtain the critical values of the test. In addition, we present a simulation study to evaluate the performance of the proposed test and compare our results to those in Pardo-Fernández et al. (2007).

  18. Development of a battery of functional tests for low vision.

    PubMed

    Dougherty, Bradley E; Martin, Scott R; Kelly, Corey B; Jones, Lisa A; Raasch, Thomas W; Bullimore, Mark A

    2009-08-01

    We describe the development and evaluation of a battery of tests of functional visual performance of everyday tasks intended to be suitable for assessment of low vision patients. The functional test battery comprises-Reading rate: reading aloud 20 unrelated words for each of four print sizes (8, 4, 2, & 1 M); Telephone book: finding a name and reading the telephone number; Medicine bottle label: reading the name and dosing; Utility bill: reading the due date and amount due; Cooking instructions: reading cooking time on a food package; Coin sorting: making a specified amount from coins placed on a table; Playing card recognition: identifying denomination and suit; and Face recognition: identifying expressions of printed, life-size faces at 1 and 3 m. All tests were timed except face and playing card recognition. Fourteen normally sighted and 24 low vision subjects were assessed with the functional test battery. Visual acuity, contrast sensitivity, and quality of life (National Eye Institute Visual Function Questionnaire 25 [NEI-VFQ 25]) were measured and the functional tests repeated. Subsequently, 23 low vision patients participated in a pilot randomized clinical trial with half receiving low vision rehabilitation and half a delayed intervention. The functional tests were administered at enrollment and 3 months later. Normally sighted subjects could perform all tasks but the proportion of trials performed correctly by the low vision subjects ranged from 35% for face recognition at 3 m, to 95% for the playing card identification. On average, low vision subjects performed three times slower than the normally sighted subjects. Timed tasks with a visual search component showed poorer repeatability. In the pilot clinical trial, low vision rehabilitation produced the greatest improvement for the medicine bottle and cooking instruction tasks. Performance of patients on these functional tests has been assessed. Some appear responsive to low vision rehabilitation.

  19. Towards tests of quark-hadron duality with functional analysis and spectral function data

    NASA Astrophysics Data System (ADS)

    Boito, Diogo; Caprini, Irinel

    2017-04-01

    The presence of terms that violate quark-hadron duality in the expansion of QCD Green's functions is a generally accepted fact. Recently, a new approach was proposed for the study of duality violations (DVs), which exploits the existence of a rigorous lower bound on the functional distance, measured in a certain norm, between a "true" correlator and its approximant calculated theoretically along a contour in the complex energy plane. In the present paper, we pursue the investigation of functional-analysis-based tests towards their application to real spectral function data. We derive a closed analytic expression for the minimal functional distance based on the general weighted L2 norm and discuss its relation with the distance measured in the L∞ norm. Using fake data sets obtained from a realistic toy model in which we allow for covariances inspired from the publicly available ALEPH spectral functions, we obtain, by Monte Carlo simulations, the statistical distribution of the strength parameter that measures the magnitude of the DV term added to the usual operator product expansion. The results show that, if the region with large errors near the end point of the spectrum in τ decays is excluded, the functional-analysis-based tests using either L2 or L∞ norms are able to detect, in a statistically significant way, the presence of DVs in realistic spectral function pseudodata.

  20. Test Protocols for Advanced Inverter Interoperability Functions - Appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already

  1. Functional performance testing in participants with functional ankle instability and in a healthy control group.

    PubMed

    Buchanan, Amanda S; Docherty, Carrie L; Schrader, John

    2008-01-01

    Functional ankle instability (FAI) affects a large part of the population. Inconsistent findings have been reported regarding the existence of functional performance deficits in individuals with FAI. To examine functional performance in participants with FAI compared with participants in a control group during 2 hopping tests. Case-control study. Athletic training research laboratory. There were 40 college-aged individuals who participated in our study: 20 with FAI and 20 without FAI. We defined FAI as history of an ankle sprain and residual episodes of "giving way." Participants completed 2 functional performance tests (FPTs): the single-limb hopping and the single-limb hurdle tests. Time to complete each test was recorded. Following each FPT, participants were asked if their ankles felt unstable during the test. We found no difference between participants in the FAI and control groups for the hopping or hurdle tests (P > .05). When asked if their ankles felt unstable during the FPTs, approximately half of the participants in the FAI group and none of the participants in the control group reported a feeling of instability. Subsequently, a secondary analysis of variance was calculated with participants grouped into 3 categories: control participants, FAI participants reporting instability symptoms during FPT (FAI-S), and FAI participants not reporting instability symptoms during FPT (FAI-NS). Results revealed a difference among the 3 groups for the single-limb hopping test (P < .01). Post hoc analysis revealed a difference between the FAI-S participants and both the control and the FAI-NS participants. No difference was identified for the single-limb hurdle test (P = .41). The FAI-S participants had performance deficits during the single-limb hopping test. Therefore, clinicians could use this simple hopping test as an additional method to determine the presence of FAI.

  2. A physical function test for use in the intensive care unit: validity, responsiveness, and predictive utility of the physical function ICU test (scored).

    PubMed

    Denehy, Linda; de Morton, Natalie A; Skinner, Elizabeth H; Edbrooke, Lara; Haines, Kimberley; Warrillow, Stephen; Berney, Sue

    2013-12-01

    Several tests have recently been developed to measure changes in patient strength and functional outcomes in the intensive care unit (ICU). The original Physical Function ICU Test (PFIT) demonstrates reliability and sensitivity. The aims of this study were to further develop the original PFIT, to derive an interval score (the PFIT-s), and to test the clinimetric properties of the PFIT-s. A nested cohort study was conducted. One hundred forty-four and 116 participants performed the PFIT at ICU admission and discharge, respectively. Original test components were modified using principal component analysis. Rasch analysis examined the unidimensionality of the PFIT, and an interval score was derived. Correlations tested validity, and multiple regression analyses investigated predictive ability. Responsiveness was assessed using the effect size index (ESI), and the minimal clinically important difference (MCID) was calculated. The shoulder lift component was removed. Unidimensionality of combined admission and discharge PFIT-s scores was confirmed. The PFIT-s displayed moderate convergent validity with the Timed "Up & Go" Test (r=-.60), the Six-Minute Walk Test (r=.41), and the Medical Research Council (MRC) sum score (rho=.49). The ESI of the PFIT-s was 0.82, and the MCID was 1.5 points (interval scale range=0-10). A higher admission PFIT-s score was predictive of: an MRC score of ≥48, increased likelihood of discharge home, reduced likelihood of discharge to inpatient rehabilitation, and reduced acute care hospital length of stay. Scoring of sit-to-stand assistance required is subjective, and cadence cutpoints used may not be generalizable. The PFIT-s is a safe and inexpensive test of physical function with high clinical utility. It is valid, responsive to change, and predictive of key outcomes. It is recommended that the PFIT-s be adopted to test physical function in the ICU.

  3. Distributed analysis functional testing using GangaRobot in the ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Legger, Federica; ATLAS Collaboration

    2011-12-01

    Automated distributed analysis tests are necessary to ensure smooth operations of the ATLAS grid resources. The HammerCloud framework allows for easy definition, submission and monitoring of grid test applications. Both functional and stress test applications can be defined in HammerCloud. Stress tests are large-scale tests meant to verify the behaviour of sites under heavy load. Functional tests are light user applications running at each site with high frequency, to ensure that the site functionalities are available at all times. Success or failure rates of these tests jobs are individually monitored. Test definitions and results are stored in a database and made available to users and site administrators through a web interface. In this work we present the recent developments of the GangaRobot framework. GangaRobot monitors the outcome of functional tests, creates a blacklist of sites failing the tests, and exports the results to the ATLAS Site Status Board (SSB) and to the Service Availability Monitor (SAM), providing on the one hand a fast way to identify systematic or temporary site failures, and on the other hand allowing for an effective distribution of the work load on the available resources.

  4. Measurement of Function Post Hip Fracture: Testing a Comprehensive Measurement Model of Physical Function

    PubMed Central

    Gruber-Baldini, Ann L.; Hicks, Gregory; Ostir, Glen; Klinedinst, N. Jennifer; Orwig, Denise; Magaziner, Jay

    2015-01-01

    Background Measurement of physical function post hip fracture has been conceptualized using multiple different measures. Purpose This study tested a comprehensive measurement model of physical function. Design This was a descriptive secondary data analysis including 168 men and 171 women post hip fracture. Methods Using structural equation modeling, a measurement model of physical function which included grip strength, activities of daily living, instrumental activities of daily living and performance was tested for fit at 2 and 12 months post hip fracture and among male and female participants and validity of the measurement model of physical function was evaluated based on how well the model explained physical activity, exercise and social activities post hip fracture. Findings The measurement model of physical function fit the data. The amount of variance the model or individual factors of the model explained varied depending on the activity. Conclusion Decisions about the ideal way in which to measure physical function should be based on outcomes considered and participant Clinical Implications The measurement model of physical function is a reliable and valid method to comprehensively measure physical function across the hip fracture recovery trajectory. Practical but useful assessment of function should be considered and monitored over the recovery trajectory post hip fracture. PMID:26492866

  5. [Eosin Y-water test for sperm function examination].

    PubMed

    Zha, Shu-wei; Lü, Nian-qing; Xu, Hao-qin

    2015-06-01

    Based on the principles of the in vitro staining technique, hypotonic swelling test, and water test, the Eosin Y-water test method was developed to simultaneously detect the integrity of the sperm head and tail and sperm membrane structure and function. As a widely used method in clinical laboratories in China, the Eosin Y-water test is methodologically characterized by three advantages. Firstly, both the sperm head and tail can be detected at the same time, which allows easy and comprehensive assessment of membrane damage in different parts of sperm. Secondly, distilled water is used instead of the usual formula solution to simplify and standardize the test by eliminating any potential effects on the water molecules through the sperm membrane due to different osmotic pressure or different sugar proportions and electrolyte solutions. Thirdly, the test takes less time and thus can be repeated before and after treatment. This article focuses on the fundamental principles and modification of the Eosin Y-water test and its application in sperm function examination and routine semen analysis for male infertility, assessment of the quality of sperm retrieved by testicular fine needle aspiration, semen cryopreservation program development, and evaluation of sperm membrane integrity after microwave radiation.

  6. An automated system for pulmonary function testing

    NASA Technical Reports Server (NTRS)

    Mauldin, D. G.

    1974-01-01

    An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.

  7. Executive Functioning Profiles and Test Anxiety in College Students

    ERIC Educational Resources Information Center

    O'Donnell, Patrick S.

    2017-01-01

    The current study attempted to answer whether a specific executive functioning profile for individuals with test anxiety exists and whether deficits in working memory are associated with an earlier onset of test anxiety. Two hundred eighty-four undergraduate students completed a survey on test anxiety and self-report measures of test anxiety and…

  8. Outcomes of anatomical versus functional testing for coronary artery disease.

    PubMed

    Douglas, Pamela S; Hoffmann, Udo; Patel, Manesh R; Mark, Daniel B; Al-Khalidi, Hussein R; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J; Fordyce, Christopher B; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S; Krucoff, Mitchell W; Malhotra, Vinay; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Yow, Eric; Cooper, Lawton S; Lee, Kerry L

    2015-04-02

    Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P=0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P=0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the National Heart, Lung, and Blood Institute

  9. Outcomes of Anatomical versus Functional Testing for Coronary Artery Disease

    PubMed Central

    Douglas, Pamela S.; Hoffmann, Udo; Patel, Manesh R.; Mark, Daniel B.; Al-Khalidi, Hussein R.; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J.; Fordyce, Christopher B.; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S.; Krucoff, Mitchell W.; Malhotra, Vinay; Picard, Michael H.; Udelson, James E.; Velazquez, Eric J.; Yow, Eric; Cooper, Lawton S.; Lee, Kerry L.

    2015-01-01

    BACKGROUND Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. METHODS We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. RESULTS The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P = 0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P = 0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). CONCLUSIONS In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the

  10. Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

    NASA Technical Reports Server (NTRS)

    Ryder, Jeffrey W.; Wickwire, P. J.; Buxton, R. E.; Bloomberg, J. J.; Ploutz-Snyder, L.

    2011-01-01

    The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely

  11. Functional Test on (TES) Thermal Enclosure System

    NASA Technical Reports Server (NTRS)

    1992-01-01

    MSFC Test Engineer performing a functional test on the TES. The TES can be operated as a refrigerator, with a minimum set point temperature of 4.0 degrees C, or as an incubator, with a maximum set point temperature 40.0 degrees C of the set point. The TES can be set to maintain a constant temperature or programmed to change temperature settings over time, internal temperature recorded by a date logger.

  12. Construct validity of functional capacity tests in healthy workers

    PubMed Central

    2013-01-01

    Background Functional Capacity (FC) is a multidimensional construct within the activity domain of the International Classification of Functioning, Disability and Health framework (ICF). Functional capacity evaluations (FCEs) are assessments of work-related FC. The extent to which these work-related FC tests are associated to bio-, psycho-, or social factors is unknown. The aims of this study were to test relationships between FC tests and other ICF factors in a sample of healthy workers, and to determine the amount of statistical variance in FC tests that can be explained by these factors. Methods A cross sectional study. The sample was comprised of 403 healthy workers who completed material handling FC tests (lifting low, overhead lifting, and carrying) and static work FC tests (overhead working and standing forward bend). The explainable variables were; six muscle strength tests; aerobic capacity test; and questionnaires regarding personal factors (age, gender, body height, body weight, and education), psychological factors (mental health, vitality, and general health perceptions), and social factors (perception of work, physical workloads, sport-, leisure time-, and work-index). A priori construct validity hypotheses were formulated and analyzed by means of correlation coefficients and regression analyses. Results Moderate correlations were detected between material handling FC tests and muscle strength, gender, body weight, and body height. As for static work FC tests; overhead working correlated fair with aerobic capacity and handgrip strength, and low with the sport-index and perception of work. For standing forward bend FC test, all hypotheses were rejected. The regression model revealed that 61% to 62% of material handling FC tests were explained by physical factors. Five to 15% of static work FC tests were explained by physical and social factors. Conclusions The current study revealed that, in a sample of healthy workers, material handling FC tests were

  13. To develop behavioral tests of vestibular functioning in the Wistar rat

    NASA Technical Reports Server (NTRS)

    Nielson, H. C.

    1980-01-01

    Two tests of vestibular functioning in the rat were developed. The first test was the water maze. In the water maze the rat does not have the normal proprioceptive feedback from its limbs to help it maintain its orientation, and must rely primarily on the sensory input from its visual and vestibular systems. By altering lighting conditions and visual cues the vestibular functioning without visual cues was assessed. Whether there was visual compensation for some vestibular dysfunction was determined. The second test measured vestibular functioning of the rat's behavior on a parallel swing. In this test the rat's postural adjustments while swinging on the swing with the otoliths being stimulated were assessed. Less success was achieved in developing the parallel swing as a test of vestibular functioning than with the water maze. The major problem was incorrect initial assumptions of what the rat's probable behavior on the parallel swing would be.

  14. Performance-intensity functions of Mandarin word recognition tests in noise: test dialect and listener language effects.

    PubMed

    Liu, Danzheng; Shi, Lu-Feng

    2013-06-01

    This study established the performance-intensity function for Beijing and Taiwan Mandarin bisyllabic word recognition tests in noise in native speakers of Wu Chinese. Effects of the test dialect and listeners' first language on psychometric variables (i.e., slope and 50%-correct threshold) were analyzed. Thirty-two normal-hearing Wu-speaking adults who used Mandarin since early childhood were compared to 16 native Mandarin-speaking adults. Both Beijing and Taiwan bisyllabic word recognition tests were presented at 8 signal-to-noise ratios (SNRs) in 4-dB steps (-12 dB to +16 dB). At each SNR, a half list (25 words) was presented in speech-spectrum noise to listeners' right ear. The order of the test, SNR, and half list was randomized across listeners. Listeners responded orally and in writing. Overall, the Wu-speaking listeners performed comparably to the Mandarin-speaking listeners on both tests. Compared to the Taiwan test, the Beijing test yielded a significantly lower threshold for both the Mandarin- and Wu-speaking listeners, as well as a significantly steeper slope for the Wu-speaking listeners. Both Mandarin tests can be used to evaluate Wu-speaking listeners. Of the 2, the Taiwan Mandarin test results in more comparable functions across listener groups. Differences in the performance-intensity function between listener groups and between tests indicate a first language and dialectal effect, respectively.

  15. Testing for cognitive function in animals in a regulatory context.

    PubMed

    Bushnell, Philip J

    2015-01-01

    Superior cognitive functions have allowed the human species to proliferate in a world of incredible biological diversity. Threats to these essential capacities cannot be ignored, and a strategy is needed to evaluate the hazard posed by exposure to chemical and other agents. Because people exposed to chemicals often complain about confusion and forgetfulness, it is commonly thought that cognitive functions should be sensitive indicators of adverse consequences of chemical exposure. For these reasons, complex tests of cognitive function have been developed and deployed in experimental animal laboratories for decades. However, the results of these tests are rarely used as points of departure for chemical risk assessments. Due to their high cost in time, animals, and equipment, the efficacy and utility of these tests need to be evaluated in relation to cheaper and faster whole-animal screening methods. This review examines evidence for the assertions that cognitive functions represent uniquely sensitive indicators of chemical exposure, and that animal models of these functions are necessary to detect and quantify the neurotoxicity of chemicals. Studies conducted since the early 1980s to compare these approaches to assess the neurotoxicity of chemicals are reviewed for both adult and perinatal exposures in experimental rodents. Forty-one studies of 35 chemicals were found that directly compared acute effects using complex tests (i.e., tests that require training animals) with acute effects using screening tests (i.e., tests that do not require training animals) in adult rodents. Complex tests detected effects of three substances (bitertanol, iso-amyl nitrite, and Pfiesteria toxin) that had no effect on screening tests; for an additional five chemicals (carbaryl, deltamethrin, methyl mercury, tetraethyl tin, and Isopar-C), complex tests identified effects at lower doses than did screening tests. Fewer comparable cases were found for developmental exposures: screening and

  16. Functional Fitness Testing Results Following Long-Duration ISS Missions.

    PubMed

    Laughlin, Mitzi S; Guilliams, Mark E; Nieschwitz, Bruce A; Hoellen, David

    2015-12-01

    Long-duration spaceflight missions lead to the loss of muscle strength and endurance. Significant reduction in muscle function can be hazardous when returning from spaceflight. To document these losses, NASA developed medical requirements that include measures of functional strength and endurance. Results from this Functional Fitness Test (FFT) battery are also used to evaluate the effectiveness of in-flight exercise countermeasures. The purpose of this paper is to document results from the FFT and correlate this information with performance of in-flight exercise on board the International Space Station. The FFT evaluates muscular strength and endurance, flexibility, and agility and includes the following eight measures: sit and reach, cone agility, push-ups, pull-ups, sliding crunches, bench press, leg press, and hand grip dynamometry. Pre- to postflight functional fitness measurements were analyzed using dependent t-tests and correlation analyses were used to evaluate the relationship between functional fitness measurements and in-flight exercise workouts. Significant differences were noted post space flight with the sit and reach, cone agility, leg press, and hand grip measurements while other test scores were not significantly altered. The relationships between functional fitness and in-flight exercise measurements showed minimal to moderate correlations for most in-flight exercise training variables. The change in FFT results can be partially explained by in-flight exercise performance. Although there are losses documented in the FFT results, it is important to realize that the crewmembers are successfully performing activities of daily living and are considered functional for normal activities upon return to Earth.

  17. An automated testing tool for traffic signal controller functionalities.

    DOT National Transportation Integrated Search

    2010-03-01

    The purpose of this project was to develop an automated tool that facilitates testing of traffic controller functionality using controller interface device (CID) technology. Benefits of such automated testers to traffic engineers include reduced test...

  18. Integrated Locomotor Function Tests for Countermeasure Evaluation

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Landsness, E. C.; Black, F. O.

    2005-01-01

    Following spaceflight crewmembers experience locomotor dysfunction due to inflight adaptive alterations in sensorimotor function. Countermeasures designed to mitigate these postflight gait alterations need to be assessed with a new generation of tests that evaluate the interaction of various sensorimotor sub-systems central to locomotor control. The goal of the present study was to develop new functional tests of locomotor control that could be used to test the efficacy of countermeasures. These tests were designed to simultaneously examine the function of multiple sensorimotor systems underlying the control of locomotion and be operationally relevant to the astronaut population. Traditionally, gaze stabilization has been studied almost exclusively in seated subjects performing target acquisition tasks requiring only the involvement of coordinated eye-head movements. However, activities like walking involve full-body movement and require coordination between lower limbs and the eye-head-trunk complex to achieve stabilized gaze during locomotion. Therefore the first goal of this study was to determine how the multiple, interdependent, full-body sensorimotor gaze stabilization subsystems are functionally coordinated during locomotion. In an earlier study we investigated how alteration in gaze tasking changes full-body locomotor control strategies. Subjects walked on a treadmill and either focused on a central point target or read numeral characters. We measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. In comparison to the point target fixation condition, the results of the number reading task showed that compensatory head pitch movements increased, peak head acceleration was reduced and knee flexion at heel-strike was increased. In a more recent study we investigated the

  19. Aging of vestibular function evaluated using correlational vestibular autorotation test

    PubMed Central

    Hsieh, Li-Chun; Lin, Hung-Ching; Lee, Guo-She

    2014-01-01

    Background Imbalance from degeneration of vestibular end organs is a common problem in the elderly. However, the decline of vestibular function with aging was revealed in few vestibular function tests such as vestibular autorotation test (VAT). In the current VAT, there are drawbacks of poor test–retest reliability, slippage of the sensor at high-speed rotations, and limited data about the effect of aging. We developed a correlational-VAT (cVAT) system that included a small, light sensor (less than 20 g) with wireless data transmission technique to evaluate the aging of vestibular function. Material and methods We enrolled 53 healthy participants aged between 25 and 75 years and divided them into five age groups. The test conditions were vertical and horizontal head autorotations of frequencies from 0 to 3 Hz with closed eyes or open eyes. The cross-correlation coefficient (CCC) between eye velocity and head velocity was obtained for the head autorotations between 1 Hz and 3 Hz. The mean of the CCCs was used to represent the vestibular function. Results Age was significantly and negatively correlated with the mean CCC for all test conditions, including horizontal or vertical autorotations with open eyes or closed eyes (P<0.05). The mean CCC with open eyes declined significantly at 55–65 years old and the mean CCC with closed eyes declined significantly at 65–75 years old. Conclusion Vestibular function evaluated using mean CCC revealed a decline with age, and the function of visual-vestibulo-ocular reflex declined 10 years earlier than the function of vestibulo-ocular reflex. PMID:25214774

  20. Hubble Space Telescope On-orbit Transfer Function Test

    NASA Technical Reports Server (NTRS)

    Vadlamudi, N.; Blair, M. A.; Clapp, B. R.

    1992-01-01

    The paper describes the On-orbit Transfer Function Test (TFT) designed for on-orbit vibration testing of the Hubble Space Telescope (HST). The TFT provides means for extracting accurate on-orbit characteristics of HST flexible body dynamics, making it possible to check periodically the state of the vehicle on-orbit and to assess changes in modal parameters.

  1. IDENTIFICATION AND CHARACTERIZATION OF DISEASE USING PULMONARY FUNCTION TESTS

    EPA Science Inventory

    Abstract
    Pulmonary function testing is used routinely in human medicine to objectively define functional deficits in individuals with respiratory disease. Despite the fact that respiratory disease is a common problem in veterinary medicine, evaluation of the small animal pa...

  2. A test for measuring gustatory function.

    PubMed

    Smutzer, Gregory; Lam, Si; Hastings, Lloyd; Desai, Hetvi; Abarintos, Ray A; Sobel, Marc; Sayed, Nabil

    2008-08-01

    The purpose of this study was to determine the usefulness of edible taste strips for measuring human gustatory function. The physical properties of edible taste strips were examined to determine their potential for delivering threshold and suprathreshold amounts of taste stimuli to the oral cavity. Taste strips were then assayed by fluorescence to analyze the uniformity and distribution of bitter tastant in the strips. Finally, taste recognition thresholds for sweet taste were examined to determine whether or not taste strips could detect recognition thresholds that were equal to or better than those obtained from aqueous tests. Edible strips were prepared from pullulan-hydroxypropyl methylcellulose solutions that were dried to a thin film. The maximal amount of a tastant that could be incorporated in a 2.54 cm2 taste strip was identified by including representative taste stimuli for each class of tastant (sweet, sour, salty, bitter, and umami) during strip formation. Distribution of the bitter tastant quinine hydrochloride in taste strips was assayed by fluorescence emission spectroscopy. The efficacy of taste strips for evaluating human gustatory function was examined by using a single series ascending method of limits protocol. Sucrose taste recognition threshold data from edible strips was then compared with results that were obtained from a standard "sip and spit" recognition threshold test. Edible films that formed from a pullulan-hydroxypropyl methylcellulose polymer mixture can be used to prepare clear, thin strips that have essentially no background taste and leave no physical presence after release of tastant. Edible taste strips could uniformly incorporate up to 5% of their composition as tastant. Taste recognition thresholds for sweet taste were over one order of magnitude lower with edible taste strips when compared with an aqueous taste test. Edible taste strips are a highly sensitive method for examining taste recognition thresholds in humans. This

  3. Transfer function tests of the Joy longwall shearer

    NASA Technical Reports Server (NTRS)

    Fisher, P. H., Jr.

    1978-01-01

    A series of operational tests was performed on the Joy longwall shearer located at the Bureau of Mines in Bructon, Pennsylvania. The purpose of these tests was to determine the transfer function and operational characteristics of the system. These characteristics will be used to generate a simulation model of the longwall shearer used in the development of the closed-loop vertical control system.

  4. Real-Time Fall Risk Assessment Using Functional Reach Test.

    PubMed

    Williams, Brian; Allen, Brandon; Hu, Zhen; True, Hanna; Cho, Jin; Harris, Austin; Fell, Nancy; Sartipi, Mina

    2017-01-01

    Falls are common and dangerous for survivors of stroke at all stages of recovery. The widespread need to assess fall risk in real time for individuals after stroke has generated emerging requests for a reliable, inexpensive, quantifiable, and remote clinical measure/tool. In order to meet these requests, we explore the Functional Reach Test (FRT) for real-time fall risk assessment and implement the FRT function in mStroke , a real-time and automatic mobile health system for poststroke recovery and rehabilitation. mStroke is designed, developed, and delivered as an Application (App) running on a hardware platform consisting of an iPad and one or two wireless body motion sensors based on different mobile health functions. The FRT function in mStroke is extensively tested on healthy human subjects to verify its concept and feasibility. Preliminary performance will be presented to justify the further exploration of the FRT function in mStroke through clinical trials on individuals after stroke, which may guide its ubiquitous exploitation in the near future.

  5. Incidence of Pneumothorax in Patients With Lymphangioleiomyomatosis Undergoing Pulmonary Function and Exercise Testing.

    PubMed

    Taveira-DaSilva, Angelo M; Julien-Williams, Patricia; Jones, Amanda M; Moss, Joel

    2016-07-01

    Because pneumothorax is frequent in lymphangioleiomyomatosis, patients have expressed concerns regarding the risk of pneumothorax associated with pulmonary function or exercise testing. Indeed, pneumothorax has been reported in patients with lung disease after both of these tests. The aim of this study was to determine the incidence of pneumothorax in patients with lymphangioleiomyomatosis during admissions to the National Institutes of Health Clinical Research Center between 1995 and 2015. Medical records were reviewed to identify patients who had a pneumothorax during their stay at the National Institutes of Health. A total of 691 patients underwent 4,523 pulmonary function tests and 1,900 exercise tests. Three patients developed pneumothorax after pulmonary function tests and/or exercise tests. The incidence of pneumothorax associated with lung function testing was 0.14 to 0.29 of 100 patients or 0.02 to 0.04 of 100 tests. The incidence of pneumothorax in patients undergoing exercise testing was 0.14 to 0.28 of 100 patients or 0.05 to 0.10 of 100 tests. The risk of pneumothorax associated with pulmonary function or exercise testing in patients with lymphangioleiomyomatosis is low. Published by Elsevier Inc.

  6. Test-retest and interrater reliability of the functional lower extremity evaluation.

    PubMed

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  7. Counting-backward test for executive function in idiopathic normal pressure hydrocephalus.

    PubMed

    Kanno, S; Saito, M; Hayashi, A; Uchiyama, M; Hiraoka, K; Nishio, Y; Hisanaga, K; Mori, E

    2012-10-01

    The aim of this study was to develop and validate a bedside test for executive function in patients with idiopathic normal pressure hydrocephalus (INPH). Twenty consecutive patients with INPH and 20 patients with Alzheimer's disease (AD) were enrolled in this study. We developed the counting-backward test for evaluating executive function in patients with INPH. Two indices that are considered to be reflective of the attention deficits and response suppression underlying executive dysfunction in INPH were calculated: the first-error score and the reverse-effect index. Performance on both the counting-backward test and standard neuropsychological tests for executive function was assessed in INPH and AD patients. The first-error score, reverse-effect index and the scores from the standard neuropsychological tests for executive function were significantly lower for individuals in the INPH group than in the AD group. The two indices for the counting-backward test in the INPH group were strongly correlated with the total scores for Frontal Assessment Battery and Phonemic Verbal Fluency. The first-error score was also significantly correlated with the error rate of the Stroop colour-word test and the score of the go/no-go test. In addition, we found that the first-error score highly distinguished patients with INPH from those with AD using these tests. The counting-backward test is useful for evaluating executive dysfunction in INPH and for differentiating between INPH and AD patients. In particular, the first-error score may reflect deficits in the response suppression related to executive dysfunction in INPH. © 2012 John Wiley & Sons A/S.

  8. Classroom-Based Strategies to Incorporate Hypothesis Testing in Functional Behavior Assessments

    ERIC Educational Resources Information Center

    Lloyd, Blair P.; Weaver, Emily S.; Staubitz, Johanna L.

    2017-01-01

    When results of descriptive functional behavior assessments are unclear, hypothesis testing can help school teams understand how the classroom environment affects a student's challenging behavior. This article describes two hypothesis testing strategies that can be used in classroom settings: structural analysis and functional analysis. For each…

  9. An Effect Size Measure for Raju's Differential Functioning for Items and Tests

    ERIC Educational Resources Information Center

    Wright, Keith D.; Oshima, T. C.

    2015-01-01

    This study established an effect size measure for differential functioning for items and tests' noncompensatory differential item functioning (NCDIF). The Mantel-Haenszel parameter served as the benchmark for developing NCDIF's effect size measure for reporting moderate and large differential item functioning in test items. The effect size of…

  10. NASA's Functional Task Test: Providing Information for an Integrated Countermeasure System

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Feiveson, A. H.; Laurie, S. S.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; Ploutz-Snyder, L. L.; Reschke, M. F.; Ryder, J. W.; hide

    2015-01-01

    Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goals of the Functional Task Test (FTT) study were to determine the effects of spaceflight on functional tests that are representative of critical exploration mission tasks and to identify the key physiological factors that contribute to decrements in performance. The FTT was comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and ISS crewmembers participated in this study. Additionally, we conducted a supporting study using the FTT protocol on subjects before and after 70 days of 6? head-down bed rest. The bed rest analog allowed us to investigate the impact of body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare them with the results obtained in our spaceflight study. Spaceflight data were collected on three sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Bed rest subjects were tested three times before bed rest and immediately after getting up from bed rest as well as 1, 6, and 12 days after reambulation. We have shown that for Shuttle, ISS and bed rest subjects, functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for

  11. Using Operational Analysis to Improve Access to Pulmonary Function Testing.

    PubMed

    Ip, Ada; Asamoah-Barnieh, Raymond; Bischak, Diane P; Davidson, Warren J; Flemons, W Ward; Pendharkar, Sachin R

    2016-01-01

    Background. Timely pulmonary function testing is crucial to improving diagnosis and treatment of pulmonary diseases. Perceptions of poor access at an academic pulmonary function laboratory prompted analysis of system demand and capacity to identify factors contributing to poor access. Methods. Surveys and interviews identified stakeholder perspectives on operational processes and access challenges. Retrospective data on testing demand and resource capacity was analyzed to understand utilization of testing resources. Results. Qualitative analysis demonstrated that stakeholder groups had discrepant views on access and capacity in the laboratory. Mean daily resource utilization was 0.64 (SD 0.15), with monthly average utilization consistently less than 0.75. Reserved testing slots for subspecialty clinics were poorly utilized, leaving many testing slots unfilled. When subspecialty demand exceeded number of reserved slots, there was sufficient capacity in the pulmonary function schedule to accommodate added demand. Findings were shared with stakeholders and influenced scheduling process improvements. Conclusion. This study highlights the importance of operational data to identify causes of poor access, guide system decision-making, and determine effects of improvement initiatives in a variety of healthcare settings. Importantly, simple operational analysis can help to improve efficiency of health systems with little or no added financial investment.

  12. Biochemical tests of placental function for assessment in pregnancy.

    PubMed

    Neilson, James P

    2012-08-15

    Biochemical tests of placental or feto-placental function were widely used in the 1960s and 1970s in high-risk pregnancies to try to predict, and thus try to avoid, adverse fetal outcome. To assess the effects of performing biochemical tests of placental function in high-risk, low-risk, or unselected pregnancies. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (10 May 2012). Controlled trials (randomized or 'quasi-randomized') that compare the use of biochemical tests of placental function in pregnancy with non-use. Trial quality was assessed and data were extracted by the review author. A single eligible trial of poor quality was identified. It involved 622 women with high-risk pregnancies who had had plasma (o)estriol estimations. Women were allocated to have their (o)estriol results revealed or concealed on the basis of hospital record number (with attendant risk of selection bias). There were no obvious differences in perinatal mortality (relative risk (RR) 0.88, 95% confidence interval (CI) 0.36 to 2.13) or planned delivery (RR 0.97, 95% CI 0.81 to 1.15) between the two groups. The available trial data do not support the use of (o)estriol estimation in high-risk pregnancies. The single small trial available does not have the power to exclude a beneficial effect but this is probably of historical interest since biochemical testing has been superseded by biophysical testing in antepartum fetal assessment.

  13. 33 CFR 157.12f - Workshop functional test requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements... the specific design of equipment. A completed workshop certificate including the delivery test... several ppm values on all measurement scales when operated on an oil appropriate for the application of...

  14. 33 CFR 157.12f - Workshop functional test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements... the specific design of equipment. A completed workshop certificate including the delivery test... several ppm values on all measurement scales when operated on an oil appropriate for the application of...

  15. Memory Hazard Functions: A Vehicle for Theory Development and Test

    ERIC Educational Resources Information Center

    Chechile, Richard A.

    2006-01-01

    A framework is developed to rigorously test an entire class of memory retention functions by examining hazard properties. Evidence is provided that the memory hazard function is not monotonically decreasing. Yet most of the proposals for retention functions, which have emerged from the psychological literature, imply that memory hazard is…

  16. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    PubMed

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  17. GROUND-WATER MODEL TESTING: SYSTEMATIC EVALUATION AND TESTING OF CODE FUNCTIONALITY AND PERFORMANCE

    EPA Science Inventory

    Effective use of ground-water simulation codes as management decision tools requires the establishment of their functionality, performance characteristics, and applicability to the problem at hand. This is accomplished through application of a systematic code-testing protocol and...

  18. An Evaluation of the Sniffer Global Optimization Algorithm Using Standard Test Functions

    NASA Astrophysics Data System (ADS)

    Butler, Roger A. R.; Slaminka, Edward E.

    1992-03-01

    The performance of Sniffer—a new global optimization algorithm—is compared with that of Simulated Annealing. Using the number of function evaluations as a measure of efficiency, the new algorithm is shown to be significantly better at finding the global minimum of seven standard test functions. Several of the test functions used have many local minima and very steep walls surrounding the global minimum. Such functions are intended to thwart global minimization algorithms.

  19. The interpretation and management of abnormal liver function tests.

    PubMed

    Simpson, M A; Freshwater, D A

    2015-01-01

    Liver function tests (LFTs) are frequently requested as part of routine health assessments on serving members of the Royal Navy (RN). In common with many investigations there are a number of abnormal results in healthy individuals (0.5 - 9% depending on test and study population). There are established patterns of LFT derangement such as cholestatic derangement, hepatocellular derangement, and failure of synthetic function. There can be indicators to the cause of the derangement by assessing the ratios of elevated assays in relation to one another. This article aims to address the definition, potential causes and further investigation of common patterns of LFT derangement found in primary care in the RN.

  20. Testing modified gravity using a marked correlation function

    NASA Astrophysics Data System (ADS)

    Armijo, Joaquí n.; Cai, Yan-Chuan; Padilla, Nelson; Li, Baojiu; Peacock, John A.

    2018-05-01

    In theories of modified gravity with the chameleon screening mechanism, the strength of the fifth force depends on environment. This induces an environment dependence of structure formation, which differs from ΛCDM. We show that these differences can be captured by the marked correlation function. With the galaxy correlation functions and number densities calibrated to match between f(R) and ΛCDM models in simulations, we show that the marked correlation functions from using either the local galaxy number density or halo mass as the marks encode extra information, which can be used to test these theories. We discuss possible applications of these statistics in observations.

  1. NASA's Functional Task Test: Informing the Design of an Integrated Countermeasure System

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2015-01-01

    The goals of the Functional Task Test (FTT) study were to determine the effects of spaceflight on functional tests that are representative of critical exploration mission tasks and to identify the key physiological factors that contribute to decrements in performance.

  2. Longitudinal timed function tests in Duchenne muscular dystrophy: ImagingDMD cohort natural history.

    PubMed

    Arora, Harneet; Willcocks, Rebecca J; Lott, Donovan J; Harrington, Ann T; Senesac, Claudia R; Zilke, Kirsten L; Daniels, Michael J; Xu, Dandan; Tennekoon, Gihan I; Finanger, Erika L; Russman, Barry S; Finkel, Richard S; Triplett, William T; Byrne, Barry J; Walter, Glenn A; Sweeney, H Lee; Vandenborne, Krista

    2018-05-09

    Tests of ambulatory function are common clinical trial endpoints in Duchenne muscular dystrophy (DMD). The ImagingDMD study has generated a large data set using these tests, which can describe the contemporary natural history of DMD in 5-12.9 year olds. 92 corticosteroid treated boys with DMD and 45 controls participated in this longitudinal study. Subjects performed the 6 minute walk test (6MWT) and timed function tests (TFTs: 10m walk/run, 4 stairs, supine to stand). Boys with DMD had impaired functional performance even at 5-6.9 years. Boys older than 7 had significant declines in function over 1 year for 10m walk/run and 6MWT. 80% of subjects could perform all functional tests at 9 years old. TFTs appear to be slightly more responsive and predictive of disease progression than 6MWT in 7-12.9 year olds. This study provides insight into the contemporary natural history of key functional endpoints in DMD. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  3. Identifying Differential Item Functioning in Multi-Stage Computer Adaptive Testing

    ERIC Educational Resources Information Center

    Gierl, Mark J.; Lai, Hollis; Li, Johnson

    2013-01-01

    The purpose of this study is to evaluate the performance of CATSIB (Computer Adaptive Testing-Simultaneous Item Bias Test) for detecting differential item functioning (DIF) when items in the matching and studied subtest are administered adaptively in the context of a realistic multi-stage adaptive test (MST). MST was simulated using a 4-item…

  4. Functional performance testing of the hip in athletes: a systematic review for reliability and validity.

    PubMed

    Kivlan, Benjamin R; Martin, Robroy L

    2012-08-01

    The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. 2b (Systematic Review of Literature).

  5. Effect of Multiple Testing Adjustment in Differential Item Functioning Detection

    ERIC Educational Resources Information Center

    Kim, Jihye; Oshima, T. C.

    2013-01-01

    In a typical differential item functioning (DIF) analysis, a significance test is conducted for each item. As a test consists of multiple items, such multiple testing may increase the possibility of making a Type I error at least once. The goal of this study was to investigate how to control a Type I error rate and power using adjustment…

  6. The interval testing procedure: A general framework for inference in functional data analysis.

    PubMed

    Pini, Alessia; Vantini, Simone

    2016-09-01

    We introduce in this work the Interval Testing Procedure (ITP), a novel inferential technique for functional data. The procedure can be used to test different functional hypotheses, e.g., distributional equality between two or more functional populations, equality of mean function of a functional population to a reference. ITP involves three steps: (i) the representation of data on a (possibly high-dimensional) functional basis; (ii) the test of each possible set of consecutive basis coefficients; (iii) the computation of the adjusted p-values associated to each basis component, by means of a new strategy here proposed. We define a new type of error control, the interval-wise control of the family wise error rate, particularly suited for functional data. We show that ITP is provided with such a control. A simulation study comparing ITP with other testing procedures is reported. ITP is then applied to the analysis of hemodynamical features involved with cerebral aneurysm pathology. ITP is implemented in the fdatest R package. © 2016, The International Biometric Society.

  7. The relationship between neuropsychological tests of visuospatial function and lobar cortical thickness.

    PubMed

    Zink, Davor N; Miller, Justin B; Caldwell, Jessica Z K; Bird, Christopher; Banks, Sarah J

    2018-06-01

    Tests of visuospatial function are often administered in comprehensive neuropsychological evaluations. These tests are generally considered assays of parietal lobe function; however, the neural correlates of these tests, using modern imaging techniques, are not well understood. In the current study we investigated the relationship between three commonly used tests of visuospatial function and lobar cortical thickness in each hemisphere. Data from 374 patients who underwent a neuropsychological evaluation and MRI scans in an outpatient dementia clinic were included in the analysis. We examined the relationships between cortical thickness, as assessed with Freesurfer, and performance on three tests: Judgment of Line Orientation (JoLO), Block Design (BD) from the Fourth edition of the Wechsler Adult Intelligence Scale, and Brief Visuospatial Memory Test-Revised Copy Trial (BVMT-R-C) in patients who showed overall average performance on these tasks. Using a series of multiple regression models, we assessed which lobe's overall cortical thickness best predicted test performance. Among the individual lobes, JoLO performance was best predicted by cortical thickness in the right temporal lobe. BD performance was best predicted by cortical thickness in the right parietal lobe, and BVMT-R-C performance was best predicted by cortical thickness in the left parietal lobe. Performance on constructional tests of visuospatial function appears to correspond best with underlying cortical thickness of the parietal lobes, while performance on visuospatial judgment tests appears to correspond best to temporal lobe thickness. Future research using voxel-wise and connectivity techniques and including more diverse samples will help further understanding of the regions and networks involved in visuospatial tests.

  8. Smoke alarm tests may not adequately indicate smoke alarm function.

    PubMed

    Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Young, Tracy

    2011-01-01

    Smoke alarms are one of the most promoted prevention strategies to reduce residential fire deaths, and they can reduce residential fire deaths by half. Smoke alarm function can be measured by two tests: the smoke alarm button test and the chemical smoke test. Using results from a randomized trial of smoke alarms, we compared smoke alarm response to the button test and the smoke test. The smoke alarms found in the study homes at baseline were tested, as well as study alarms placed into homes as part of the randomized trial. Study alarms were tested at 12 and 42 months postinstallation. The proportion of alarms that passed the button test but not the smoke test ranged from 0.5 to 5.8% of alarms; this result was found most frequently among ionization alarms with zinc or alkaline batteries. These alarms would indicate to the owner (through the button test) that the smoke alarm was working, but the alarm would not actually respond in the case of a fire (as demonstrated by failing the smoke test). The proportion of alarms that passed the smoke test but not the button test ranged from 1.0 to 3.0%. These alarms would appear nonfunctional to the owner (because the button test failed), even though the alarm would operate in response to a fire (as demonstrated by passing the smoke test). The general public is not aware of the potential for inaccuracy in smoke alarm tests, and burn professionals can advocate for enhanced testing methods. The optimal test to determine smoke alarm function is the chemical smoke test.

  9. The Functional Task Test: Results from the One-Year Mission

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2017-01-01

    Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems including sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goal of our recently completed Functional Task Test (FTT) study was to determine the effects of spaceflight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. The FTT is comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures specifically targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and International Space Station (ISS) astronauts were tested before and after spaceflight. Additionally, we conducted a supporting study in which subjects performed the FTT protocol before and after 70 days of 6 deg head-down bed rest, an analog for spaceflight. Two groups of bed rest subjects were studied: one group who performed aerobic and resistive exercise during bed rest using protocols similar to astronauts and one group who served as non-exercise controls. The bed rest analog allowed us to isolate the impact of body unloading without other spaceflight environmental factors on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare those results with the results obtained in our spaceflight study. As an extension to the FTT study we collected data from one ISS crewmember who experienced 340 days in space using the same FTT protocol used previously to test spaceflight and bed rest subjects. Data were collected three times preflight and 1.7, 7.5 and 36.5 days after

  10. Test Protocols for Advanced Inverter Interoperability Functions – Main Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are

  11. FUNCTIONAL PERFORMANCE TESTING OF THE HIP IN ATHLETES: A SYSTEMATIC REVIEW FOR RELIABILITY AND VALIDITY

    PubMed Central

    Martin, RobRoy L.

    2012-01-01

    Purpose/Background: The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. Methods: A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. Results: The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Conclusions: Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. Level of Evidence: 2b (Systematic Review of Literature) PMID:22893860

  12. INTERPRETATIONS AND LIMITATION OF PULMONARY FUNCTION TESTING IN SMALL LABORATORY ANIMALS

    EPA Science Inventory

    Pulmonary function tests are tools available to the researcher and clinician to evaluate the ability of the lung to perform its essential function of gas exchange. o meet this principal function, the lung needs to operate efficiently with minimal mechanical work as well as provid...

  13. Limits of clinical tests to screen autonomic function in diabetes type 1.

    PubMed

    Ducher, M; Bertram, D; Sagnol, I; Cerutti, C; Thivolet, C; Fauvel, J P

    2001-11-01

    A precocious detection of cardiac autonomic dysfunction is of major clinical interest that could lead to a more intensive supervision of diabetic patients. However, classical clinical exploration of cardiac autonomic function is not easy to undertake in a reproducible way. Thus, respective interests of autonomic nervous parameters provided by both clinical tests and computerized analysis of resting blood pressure were checked in type 1 diabetic patients without orthostatic hypotension and microalbuminuria. Thirteen diabetic subjects matched for age and gender to thirteen healthy subjects volunteered to participate to the study. From clinical tests (standing up, deep breathing, Valsalva maneuver, handgrip test), autonomic function was scored according to Ewing's methodology. Analysis of resting beat to beat blood pressure provided autonomic indices of the cardiac function (spectral analysis or Z analysis). 5 of the 13 diabetic patients exhibited a pathological score (more than one pathological response) suggesting the presence of cardiovascular autonomic dysfunction. The most discriminative test was the deep breathing test. However, spectral indices of BP recordings and baro-reflex sensitivity (BRS) of these 5 subjects were similar to those of healthy subjects and of remaining diabetic subjects. Alteration in Ewing's score given by clinical tests may not reflect an alteration of cardiac autonomic function in asymptomatic type 1 diabetic patients, because spectral indices of sympathetic and parasympathetic (including BRS) function were within normal range. Our results strongly suggest to confront results provided by both methodologies before concluding to an autonomic cardiac impairment in asymptomatic diabetic patients.

  14. Test functions for three-dimensional control-volume mixed finite-element methods on irregular grids

    USGS Publications Warehouse

    Naff, R.L.; Russell, T.F.; Wilson, J.D.; ,; ,; ,; ,; ,

    2000-01-01

    Numerical methods based on unstructured grids, with irregular cells, usually require discrete shape functions to approximate the distribution of quantities across cells. For control-volume mixed finite-element methods, vector shape functions are used to approximate the distribution of velocities across cells and vector test functions are used to minimize the error associated with the numerical approximation scheme. For a logically cubic mesh, the lowest-order shape functions are chosen in a natural way to conserve intercell fluxes that vary linearly in logical space. Vector test functions, while somewhat restricted by the mapping into the logical reference cube, admit a wider class of possibilities. Ideally, an error minimization procedure to select the test function from an acceptable class of candidates would be the best procedure. Lacking such a procedure, we first investigate the effect of possible test functions on the pressure distribution over the control volume; specifically, we look for test functions that allow for the elimination of intermediate pressures on cell faces. From these results, we select three forms for the test function for use in a control-volume mixed method code and subject them to an error analysis for different forms of grid irregularity; errors are reported in terms of the discrete L2 norm of the velocity error. Of these three forms, one appears to produce optimal results for most forms of grid irregularity.

  15. Video Head Impulse Testing (vHIT) and the Assessment of Horizontal Semicircular Canal Function.

    PubMed

    Riska, Kristal M; Murnane, Owen; Akin, Faith W; Hall, Courtney

    2015-05-01

    Vestibular function (specifically, horizontal semicircular canal function) can be assessed across a broad frequency range using several different techniques. The head impulse test is a qualitative test of horizontal semicircular canal function that can be completed at bedside. Recently, a new instrument (video head impulse test [vHIT]) has been developed to provide an objective assessment to the clinical test. Questions persist regarding how this test may be used in the overall vestibular test battery. The purpose of this case report is to describe vestibular test results (vHIT, rotational testing, vestibular evoked myogenic potentials, and balance and gait performance) in an individual with a 100% unilateral caloric weakness who was asymptomatic for dizziness, vertigo or imbalance. Comprehensive assessment was completed to evaluate vestibular function. Caloric irrigations, rotary chair testing, vHIT, and vestibular evoked myogenic potentials were completed. A 100% left-sided unilateral caloric weakness was observed in an asymptomatic individual. vHIT produced normal gain with covert saccades. This case demonstrates the clinical usefulness of vHIT as a diagnostic tool and indicator of vestibular compensation and functional status. American Academy of Audiology.

  16. Overcoming EMT-driven therapeutic resistance by BH3 mimetics.

    PubMed

    Keitel, Ulrike; Scheel, Christina; Dobbelstein, Matthias

    2014-01-01

    Epithelial-mesenchymal transition (EMT) contributes to the progression of cancer through enhanced invasion and stem-like properties of cancer cells. Additionally, EMT confers resistance towards many chemotherapeutics. We recently described a mechanism that mediates EMT-driven chemoresistance through augmented levels of Bcl-xL, an anti-apoptotic member of the Bcl-2 family (Keitel et al., Oncotarget, in press). Here, we elaborate on how these findings pertain to cancer cells dispersed in the tumor-adjacent stroma of breast cancer tissues, and how BH3-mimetics may provide a therapeutic strategy to eliminate cancer cell populations that have passed through an EMT.

  17. Motor function tests for 0-2-year-old children - a systematic review.

    PubMed

    Kjølbye, Camilla Buch; Drivsholm, Thomas Bo; Ertmann, Ruth Kirk; Lykke, Kirsten; Rasmussen, Rasmus Køster

    2018-06-01

    There is no evidence on how motor function is best evaluated in children in a low-risk setting. The method used in the Danish Preventive Child Health Examination Programme (DPCHEP) in general practise has not been validated. The objective of this review was to identify existing motor function tests for 0-2-year-old children that were validated for use in the background population and which are suitable for use in the DPCHEP. This systematic review was conducted in accordance with the PRISMA guidelines. A systematic literature search was performed in PubMed, Embase, SwedMed, PsycInfo and CINAHL in accordance with the inclusion and exclusion criteria. Five motor function tests were identified. The Alberta Infant Motor Scale (AIMS) exclusively assesses motor function, the Harris Infant Neuromotor Assessment also assesses cognition and the Early Motor Questionnaire (EMQ) additionally assesses perception-action integration skills. The Ages and Stages Questionnaire (ASQ) and The Brigance Infant and Toddler Screen include further aspects of development. All test methods, except for the AIMS, are based on parent involvement. For implementation in the DPCHEP, five motor function tests were potentially adequate. However, the time consumption and extensive use of tools render three of the five tests unsuitable for implementation in the existing programme. The two remaining tests, the ASQ and the EMQ, are parent questionnaires. We suggest that these should be pilot tested with a view to their subsequent implementation in the DPCHEP. It may be considered to present the test elements in a more manageable and systematic way, possibly with illustrations. Articles published in the DMJ are “open access”. This means that the articles are distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits any non-commercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

  18. Improving the Sandia Test Protocols with Advanced Inverter Functionality Testing of INV3, VV11, FW21, and L/HVRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean

    2013-11-01

    Sandia National Laboratories has created a test protocol for IEC TR 61850-90-7 advanced distributed energy resource (DER) functions, titled "Test Protocols for Advanced Inverter Interoperability Functions," often referred to as the Sandia Test Protocols. This document is currently in draft form, but has been shared with stakeholders around the world with the ultimate goal of collaborating to create a consensus set of test protocols which can be then incorporated into an International Electrotechnical Commission (IEC) and/or Underwriters Laboratories (UL) certification standard. The protocols are designed to ensure functional interoperability of DER (primarily photovoltaic (PV) inverters and energy storage systems) asmore » specified by the IEC technical report through communication and electrical tests. In this report, Sandia exercises the electrical characterization portion of the test protocols for four functions: constant power factor (INV3), volt-var (VV11), frequency-watt (FW21), and Low and High Voltage Ride Through (L/HVRT). The goal of the tests reported here was not to characterize the performance of the equipment under test (EUT), but rather to (a) exercise the draft Sandia Test Protocols in order to identify any revisions needed in test procedures, conditions, or equipment and (b) gain experience with state-of-the-art DER equipment to determine if the tests put unrealistic or overly aggressive requirements on EUT operation. In performing the work according to the current versions of the protocols, Sandia was able to identify weaknesses in the current versions and suggest improvements to the test protocols.« less

  19. 13C-Mixed Triglyceride Breath Test and Fecal Elastase as an Indirect Pancreatic Function Test in Cystic Fibrosis Infants.

    PubMed

    Kent, Dorothea Stark; Remer, Thomas; Blumenthal, Caron; Hunt, Sharon; Simonds, Sharon; Egert, Sarah; Gaskin, Kevin J

    2018-05-01

    The 'gold standard' test for the indirect determination of pancreatic function status in infants with cystic fibrosis (CF), the 72-hour fecal fat excretion test, is likely to become obsolete in the near future. Alternative indirect pancreatic function tests with sufficient sensitivity and specificity to determine pancreatic phenotype need further evaluation in CF infants. Evaluation of the clinical utility of both the noninvasive, nonradioactive C-mixed triglyceride (MTG) breath test and fecal elastase-1 (FE1) in comparison with the 72-hour fecal fat assessment in infants with CF. C-MTG breath test and the monoclonal and polyclonal FE1 assessment in stool was compared with the 72-hour fecal fat assessment in 24 infants with CF. Oral pancreatic enzyme substitution (PERT; if already commenced) was stopped before the tests. Sensitivity rates between 82% and 100% for CF patients with pancreatic insufficiency assessed by both the C-MTG breath test and the FE1 tests proved to be high and promising. The C-MTG breath test (31%-38%) as well as both FE1 tests assessed by the monoclonal (46%-54%) and the polyclonal (45%) ELISA kits, however, showed unacceptably low-sensitivity rates for the detection of pancreatic-sufficient CF patients in the present study. The C-MTG breath test with nondispersive infrared spectroscopy (NDIRS) technique, as well as both FE1 tests, are not alternatives to the fecal fat balance test for the evaluation of pancreatic function in CF infants during the first year of life.

  20. Effect of Differential Item Functioning on Test Equating

    ERIC Educational Resources Information Center

    Kabasakal, Kübra Atalay; Kelecioglu, Hülya

    2015-01-01

    This study examines the effect of differential item functioning (DIF) items on test equating through multilevel item response models (MIRMs) and traditional IRMs. The performances of three different equating models were investigated under 24 different simulation conditions, and the variables whose effects were examined included sample size, test…

  1. Test-specific control conditions for functional analyses.

    PubMed

    Fahmie, Tara A; Iwata, Brian A; Querim, Angie C; Harper, Jill M

    2013-01-01

    Most functional analyses of problem behavior include a common condition (play or noncontingent reinforcement) as a control for both positive and negative reinforcement. However, test-specific conditions that control for each potential source of reinforcement may be beneficial occasionally. We compared responding during alone, ignore, play, and differential reinforcement of other behavior (DRO) control conditions for individuals whose problem behavior was maintained by positive or negative reinforcement. Results showed that all of the conditions were effective controls for problem behavior maintained by positive reinforcement; however, the DRO condition was consistently ineffective as a control for problem behavior maintained by negative reinforcement. Implications for the design of functional analyses and future research are discussed. © Society for the Experimental Analysis of Behavior.

  2. An automated miniaturized Haploscope for testing binocular visual function

    NASA Technical Reports Server (NTRS)

    Decker, T. A.; Williams, R. E.; Kuether, C. L.; Wyman-Cornsweet, D.

    1976-01-01

    A computer-controlled binocular vision testing device has been developed as one part of a system designed for NASA to test the vision of astronauts during spaceflight. The device, called the Mark III Haploscope, utilizes semi-automated psychophysical test procedures to measure visual acuity, stereopsis, phorias, fixation disparity and accommodation/convergence relationships. All tests are self-administered, yield quantitative data and may be used repeatedly without subject memorization. Future applications of this programmable, compact device include its use as a clinical instrument to perform routine eye examinations or vision screening, and as a research tool to examine the effects of environment or work-cycle upon visual function.

  3. Reliability and validity of functional performance tests in dancers with hip dysfunction.

    PubMed

    Kivlan, Benjamin R; Carcia, Christopher R; Clemente, F Richard; Phelps, Amy L; Martin, Robroy L

    2013-08-01

    Quasi-experimental, repeated measures. Functional performance tests that identify hip joint impairments and assess the effect of intervention have not been adequately described for dancers. The purpose of this study was to examine the reliability and validity of hop and balance tests among a group of dancers with musculoskeletal pain in the hip region. NINETEEN FEMALE DANCERS (AGE: 18.90±1.11 years; height: 164.85±6.95 cm; weight: 60.37±8.29 kg) with unilateral hip pain were assessed utilizing the cross-over reach, medial triple hop, lateral triple hop, and cross-over hop tests on two occasions, 2 days apart. Test-retest reliability and comparisons between the involved and uninvolved side for each respective test were determined. Intra-class correlation coefficients for the functional performance tests ranged from 0.89-0.96. The cross-over reach test had a SEM of 2.79 cm and a MDC of 7.73 cm. The medial and lateral triple hop tests had SEM values of 7.51 cm and 8.17 cm, and MDC values of 20.81 cm and 22.62 cm, respectively. The SEM was 0.15 seconds and the MDC was 0.42 seconds for the cross-over hop test. Performance on the medial triple hop test was significantly less on the involved side (370.21±38.26 cm) compared to the uninvolved side (388.05±41.49 cm); t(18) = -4.33, p<0.01. The side-to-side comparisons of the cross-over reach test (involved mean=61.68±10.9 cm; uninvolved mean=61.69±8.63 cm); t(18) = -0.004, p=0.99, lateral triple hop test (involved mean=306.92±35.79 cm; uninvolved mean=310.68±24.49 cm); t(18) = -0.55, p=0.59, and cross-over hop test (involved mean=2.49±0.34 seconds; uninvolved mean= 2.61±0.42 seconds; t(18) = -1.84, p=0.08) were not statistically different between sides. The functional performance tests used in this study can be reliably performed on dancers with unilateral hip pain. The medial triple hop test was the only functional performance test with evidence of validity in side-to-side comparisons. These results suggest that

  4. RELIABILITY AND VALIDITY OF FUNCTIONAL PERFORMANCE TESTS IN DANCERS WITH HIP DYSFUNCTION

    PubMed Central

    Carcia, Christopher R.; Clemente, F. Richard; Phelps, Amy L.; Martin, RobRoy L.

    2013-01-01

    Study Design: Quasi-experimental, repeated measures. Purpose/Background: Functional performance tests that identify hip joint impairments and assess the effect of intervention have not been adequately described for dancers. The purpose of this study was to examine the reliability and validity of hop and balance tests among a group of dancers with musculoskeletal pain in the hip region. Methods: Nineteen female dancers (age: 18.90±1.11 years; height: 164.85±6.95 cm; weight: 60.37±8.29 kg) with unilateral hip pain were assessed utilizing the cross-over reach, medial triple hop, lateral triple hop, and cross-over hop tests on two occasions, 2 days apart. Test-retest reliability and comparisons between the involved and uninvolved side for each respective test were determined. Results: Intra-class correlation coefficients for the functional performance tests ranged from 0.89-0.96. The cross-over reach test had a SEM of 2.79 cm and a MDC of 7.73 cm. The medial and lateral triple hop tests had SEM values of 7.51 cm and 8.17 cm, and MDC values of 20.81 cm and 22.62 cm, respectively. The SEM was 0.15 seconds and the MDC was 0.42 seconds for the cross-over hop test. Performance on the medial triple hop test was significantly less on the involved side (370.21±38.26 cm) compared to the uninvolved side (388.05±41.49 cm); t(18) = −4.33, p<0.01. The side-to-side comparisons of the cross-over reach test (involved mean=61.68±10.9 cm; uninvolved mean=61.69±8.63 cm); t(18) = −0.004, p=0.99, lateral triple hop test (involved mean=306.92±35.79 cm; uninvolved mean=310.68±24.49 cm); t(18) = −0.55, p=0.59, and cross-over hop test (involved mean=2.49±0.34 seconds; uninvolved mean= 2.61±0.42 seconds; t(18) = −1.84, p=0.08) were not statistically different between sides. Conclusion: The functional performance tests used in this study can be reliably performed on dancers with unilateral hip pain. The medial triple hop test was the only functional performance test with

  5. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    ERIC Educational Resources Information Center

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  6. Muscular exercise can cause highly pathological liver function tests in healthy men.

    PubMed

    Pettersson, Jonas; Hindorf, Ulf; Persson, Paula; Bengtsson, Thomas; Malmqvist, Ulf; Werkström, Viktoria; Ekelund, Mats

    2008-02-01

    The occurrence of idiosyncratic drug hepatotoxicity is a major problem in all phases of clinical drug development and the leading cause of postmarketing warnings and withdrawals. Physical exercise can result in transient elevations of liver function tests. There is no consensus in the literature on which forms of exercise may cause changes in liver function tests and to what extent. Weightlifting results in profound increases in liver function tests in healthy men used to moderate physical activity, not including weightlifting. Liver function tests are significantly increased for at least 7 days after weightlifting. It is important to impose relevant restrictions on heavy muscular exercise prior to and during clinical studies. To investigate the effect of intensive muscular exercise (weightlifting) on clinical chemistry parameters reflecting liver function in healthy men. Fifteen healthy men, used to moderate physical activity not including weightlifting, performed an 1 h long weightlifting programme. Blood was sampled for clinical chemistry parameters [aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LD), gamma-glutamyl transferase (gamma GT), alkaline phosphatase (ALP), bilirubin, creatine kinase (CK) and myoglobin] at repeated intervals during 7 days postexercise and at a follow-up examination 10-12 days postexercise. Five out of eight studied clinical chemistry parameters (AST, ALT, LD, CK and myoglobin) increased significantly after exercise (P < 0.01) and remained increased for at least 7 days postexercise. Bilirubin, gamma GT and ALP remained within the normal range. The liver function parameters, AST and ALT, were significantly increased for at least 7 days after the exercise. In addition, LD and, in particular, CK and myoglobin showed highly elevated levels. These findings highlight the importance of imposing restrictions on weightlifting prior to and during clinical studies. Intensive muscular exercise, e

  7. QDIRT: Quantitative Direct and Indirect Testing of Sudomotor Function

    PubMed Central

    Gibbons, Christopher H.; Illigens, Ben MW; Centi, Justin; Freeman, Roy

    2011-01-01

    Objective To develop a novel assessment of sudomotor function. Background Post-ganglionic sudomotor function is currently evaluated using quantitative sudomotor axon reflex testing (QSART) or silicone impressions. We hypothesize that high-resolution digital photography has advanced sufficiently to allow quantitative direct and indirect testing of sudomotor function (QDIRT) with spatial and temporal resolution comparable to these techniques. Methods Sweating in 10 humans was stimulated on both forearms by iontophoresis of 10% acetylcholine. Silicone impressions were made and topical indicator dyes were digitally photographed every 15 seconds for 7 minutes after iontophoresis. Sweat droplets were quantified by size, location and percent surface area. Each test was repeated 8 times in each subject on alternating arms over 2 months. Another 10 subjects had silicone impressions, QDIRT and QSART performed on the dorsum of the right foot. Results The percent area of sweat photographically imaged correlated with silicone impressions at 5 minutes on the forearm (r = 0.92, p<0.01) and dorsal foot (r=0.85, p<0.01). The number of sweat droplets assessed with QDIRT correlated with the silicone impression although the droplet number was lower (162±28 vs. 341±56, p<0.01; r =0.83, p<0.01). QDIRT and QSART sudomotor assessments measured at the dorsum of the foot correlated (sweat response (r=0.63, p<0.05) and sweat onset latency (r=0.52, p<0.05). Conclusions QDIRT measured both the direct and indirect sudomotor response with spatial resolution similar to silicone impressions, and with temporal resolution that is similar to QSART. QDIRT provides a novel tool for the evaluation of post-ganglionic sudomotor function. PMID:18541883

  8. The impact of pancreaticoduodenectomy on endocrine and exocrine pancreatic function: A prospective cohort study based on pre- and postoperative function tests.

    PubMed

    Roeyen, Geert; Jansen, Miet; Hartman, Vera; Chapelle, Thiery; Bracke, Bart; Ysebaert, Dirk; De Block, Christophe

    Studies reporting on function after pancreatic surgery are frequently based on diabetes history, fasting glycemia or random glycemia. The aim of this study was to investigate prospectively the evolution of pancreatic function in patients undergoing pancreaticoduodenectomy based on proper pre- and postoperative function tests. It was hypothesised that pancreatic function deteriorates after pancreaticoduodenectomy. Between 2013 and 2016, 78 patients undergoing pancreaticoduodenectomy for oncologic indications had a prospective evaluation of their endocrine and exocrine pancreatic function. Endocrine function was evaluated with the 75 g oral glucose tolerance test (OGTT) and the 1 mg intravenous glucagon test. Exocrine function was evaluated with a 13C-labelled mixed-triglyceride breath test. Tests were performed pre- and postoperatively. In 90.5% (19/21) of patients with preoperatively known diabetes, no change in endocrine function was observed. In contrast, endocrine function improved in 68.1% (15/22) of patients with newly diagnosed diabetes. 40% (14/35) of patients with a preoperative normal OGTT or prediabetes experienced deterioration in function. In multivariate analysis, improvement of newly diagnosed diabetes was correlated with preoperative bilirubin levels (p = 0.045), while progression towards diabetes was correlated with preoperative C-peptidogenic index T 30 (p = 0.037). A total of 20.5% (16/78) of patients had pancreatic exocrine insufficiency preoperatively. Another 51.3% (40/78) of patients deteriorated on exocrine level. In total, 64.1% (50/78) of patients required pancreatic enzyme-replacement therapy postoperatively. Although deterioration of endocrine function was expected after pancreatic resection, improvement is frequently observed in patients with newly diagnosed diabetes. Exocrine function deteriorates after pancreaticoduodenectomy. Copyright © 2017 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  9. Advanced Grid Support Functionality Testing for Florida Power and Light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Austin; Martin, Gregory; Hurtt, James

    This report describes the results of laboratory testing of advanced photovoltaic (PV) inverter testing undertaken by the National Renewable Energy Laboratory (NREL) on behalf of the Florida Power and Light Company (FPL). FPL recently commissioned a 1.1 MW-AC PV installation on a solar carport at the Daytona International Speedway in Daytona Beach, Florida. In addition to providing a source of clean energy production, the site serves as a live test bed with 36 different PV inverters from eight different manufacturers. Each inverter type has varied support for advanced grid support functions (GSFs) that are becoming increasingly commonplace, and are beingmore » required through revised interconnection standards such as UL1741, IEEE1547, and California (CA) Rule 21. FPL is interested in evaluating the trade-offs between different GSFs, their compliance to emerging standards, and their effects on efficiency and reliability. NREL has provided a controlled laboratory environment to undertake such a study. This work covered nine different classes of tests to compare inverter capabilities and performance for four different inverters that were selected by FPL. The test inverters were all three-phase models rated between 24-36 kW, and containing multiple PV input power point trackers. Advanced grid support functions were tested for functional behavior, and included fixed power factor operation, voltage-ride through, frequency ride-through, volt-var control, and frequency-Watt control. Response to abnormal grid conditions with GSFs enabled was studied through anti-islanding, fault, and load rejection overvoltage tests. Finally, efficiency was evaluated across a range of operating conditions that included power factor, output power, and input voltage variations. Test procedures were derived from requirements of a draft revision of UL741, CA Rule 21, and/or previous studies at NREL. This reports summarizes the results of each test case, providing a comparative performance

  10. Analysis of current thyroid function test ordering practices.

    PubMed

    Kluesner, Joseph K; Beckman, Darrick J; Tate, Joshua M; Beauvais, Alexis A; Kravchenko, Maria I; Wardian, Jana L; Graybill, Sky D; Colburn, Jeffrey A; Folaron, Irene; True, Mark W

    2018-04-01

    Current guidelines recommend thyroid stimulating hormone (TSH) alone as the best test to detect and monitor thyroid dysfunction, yet free thyroxine (FT4) and free triiodothyronine (FT3) are commonly ordered when not clinically indicated. Excessive testing can lead to added economic burden in an era of rising healthcare costs, while rarely contributing to the evaluation or management of thyroid disease. To evaluate our institution's practice in ordering thyroid function tests (TFTs) and to identify strategies to reduce inappropriate FT4 and FT3 testing. A record of all TFTs obtained in the San Antonio Military Health System during a 3-month period was extracted from the electronic medical record. The TFTs of interest were TSH, FT4, thyroid panel (TSH + FT4), FT3, total thyroxine (T4), and total triiodothyronine (T3). These were categorized based on the presence or absence of hypothyroidism. Between August 1 and October 31, 2016, there were 38 214 individual TFTs ordered via 28 597 total laboratory requests; 11 486 of these requests were in patients with a history of hypothyroidism. The number (percent) of laboratory requests fell into these patterns: TSH alone 14 919 (52.14%), TSH + FT4 7641 (26.72%), FT3 alone 3039 (10.63%), FT4 alone 1219 (4.26%), TSH + FT4 + FT3 783 (2.74%), and others 996 (3.48%); 36.0% of TFTs ordered were free thyroid hormones. Projected out to a year, using Department of Defense laboratory costs, $317 429 worth of TFTs would be ordered, with free thyroid hormone testing accounting for $107 720. Inappropriate ordering of free thyroid hormone tests is common. In an era of rising healthcare costs, inappropriate thyroid function testing is an ideal target for efforts to reduce laboratory overutilization, which in our system, could save up to $120 000 per year. Further evaluation is needed to determine strategies that can reduce excessive thyroid hormone testing. Published 2017. This article is a U.S. Government work and is in the

  11. A computer system for processing data from routine pulmonary function tests.

    PubMed Central

    Pack, A I; McCusker, R; Moran, F

    1977-01-01

    In larger pulmonary function laboratories there is a need for computerised techniques of data processing. A flexible computer system, which is used routinely, is described. The system processes data from a relatively large range of tests. Two types of output are produced--one for laboratory purposes, and one for return to the referring physician. The system adds an automatic interpretative report for each set of results. In developing the interpretative system it has been necessary to utilise a number of arbitrary definitions. The present terminology for reporting pulmonary function tests has limitations. The computer interpretation system affords the opportunity to take account of known interaction between measurements of function and different pathological states. Images PMID:329462

  12. Request of thyroid function tests from Primary Care in Spain.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Pomares, Francisco J; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2016-01-01

    Laboratory tests are crucial for diagnosis and monitoring of thyroid disorders. It is therefore necessary to study the pattern and variability in requests of thyroid function tests. The study objectives were to compare the inter-regional variability in the request of laboratory thyroid tests by general practitioners (GPs) in Spain, and to investigate the potential economic savings if the goals set for some suitability indicators were reached. Test requests per 1,000 inhabitants and test ratios (free thyroxine (FT4)/thyrotropin (TSH), free triiodothyronine (FT3)/TSH, thyroglobulin antibody (TgAb)/peroxidase antibody (TPOAb)) were compared between the different areas, according to their setting, location, and management. The resulting savings if each department achieved the goals for indicator (0.25 for FT4/TSH, 0.1 for FT3/TSH) were estimated. Seventy-six laboratories covering a population of 17,679,195 inhabitants participated in the study. TSH was requested significantly less in urban-rural areas, and the requests for FT3/1,000 inhabitants, FT3/TSH, and TgAb/TPOAb were higher in departments with private management. The savings generated if specifications for the ratios of related tests were met would be 937,260.5 €. The high variability reported in requests for thyroid function and autoimmunity tests in Spain suggests the need for implementing strategies to improve use of such tests. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  13. Pulmonary Function Tests

    MedlinePlus

    ... heavily for at least 30 minutes before the test. ■■ Do not wear tight clothing that makes it difficult for you ... be blowing into a tube connected to a machine (spirometer). To get the “best” test result, the test is repeated three times. You ...

  14. Patient and Societal Value Functions for the Testing Morbidities Index

    PubMed Central

    Swan, John Shannon; Kong, Chung Yin; Lee, Janie M.; Akinyemi, Omosalewa; Halpern, Elkan F.; Lee, Pablo; Vavinskiy, Sergey; Williams, Olubunmi; Zoltick, Emilie S.; Donelan, Karen

    2013-01-01

    Background We developed preference-based and summated scale scoring for the Testing Morbidities Index (TMI) classification, which addresses short-term effects on quality of life from diagnostic testing before, during and after a testing procedure. Methods The two TMI value functions utilize multiattribute value techniques; one is patient-based and the other has a societal perspective. 206 breast biopsy patients and 466 (societal) subjects informed the models. Due to a lack of standard short-term methods for this application, we utilized the visual analog scale (VAS). Waiting trade-off (WTO) tolls provided an additional option for linear transformation of the TMI. We randomized participants to one of three surveys: the first derived weights for generic testing morbidity attributes and levels of severity with the VAS; a second developed VAS values and WTO tolls for linear transformation of the TMI to a death-healthy scale; the third addressed initial validation in a specific test (breast biopsy). 188 patients and 425 community subjects participated in initial validation, comparing direct VAS and WTO values to the TMI. Alternative TMI scoring as a non-preference summated scale was included, given evidence of construct and content validity. Results The patient model can use an additive function, while the societal model is multiplicative. Direct VAS and the VAS-scaled TMI were correlated across modeling groups (r=0.45 to 0.62) and agreement was comparable to the value function validation of the Health Utilities Index 2. Mean Absolute Difference (MAD) calculations showed a range of 0.07–0.10 in patients and 0.11–0.17 in subjects. MAD for direct WTO tolls compared to the WTO-scaled TMI varied closely around one quality-adjusted life day. Conclusions The TMI shows initial promise in measuring short-term testing-related health states. PMID:23689044

  15. Validity of an Interactive Functional Reach Test.

    PubMed

    Galen, Sujay S; Pardo, Vicky; Wyatt, Douglas; Diamond, Andrew; Brodith, Victor; Pavlov, Alex

    2015-08-01

    Videogaming platforms such as the Microsoft (Redmond, WA) Kinect(®) are increasingly being used in rehabilitation to improve balance performance and mobility. These gaming platforms do not have built-in clinical measures that offer clinically meaningful data. We have now developed software that will enable the Kinect sensor to assess a patient's balance using an interactive functional reach test (I-FRT). The aim of the study was to test the concurrent validity of the I-FRT and to establish the feasibility of implementing the I-FRT in a clinical setting. The concurrent validity of the I-FRT was tested among 20 healthy adults (mean age, 25.8±3.4 years; 14 women). The Functional Reach Test (FRT) was measured simultaneously by both the Kinect sensor using the I-FRT software and the Optotrak Certus(®) 3D motion-capture system (Northern Digital Inc., Waterloo, ON, Canada). The feasibility of implementing the I-FRT in a clinical setting was assessed by performing the I-FRT in 10 participants with mild balance impairments recruited from the outpatient physical therapy clinic (mean age, 55.8±13.5 years; four women) and obtaining their feedback using a NASA Task Load Index (NASA-TLX) questionnaire. There was moderate to good agreement between FRT measures made by the two measurement systems. The greatest agreement between the two measurement system was found with the Kinect sensor placed at a distance of 2.5 m [intraclass correlation coefficient (2,k)=0.786; P<0.001] from the participant. Participants with mild balance impairments whose balance was assessed using the I-FRT software scored their experience favorably by assigning lower scores for the Frustration, Mental Demand, and Temporal Demand subscales on the NASA/TLX questionnaire. FRT measures made using the Kinect sensor I-FRT software provides a valid clinical measure that can be used with the gaming platforms.

  16. Atherosclerosis and Liver Function Tests in Coronary Angiography Patients.

    PubMed

    Doganer, Y C; Rohrer, J E; Aydogan, U; Agerter, D C; Cayci, T; Barcin, C

    2015-09-01

    Elevated aminotransferase levels indicating liver function, even in the normal range, have attracted great concern as potential novel markers of cardiovascular risk assessment. We hypothesized the possibility that liver function test variations in the normal range might be meaningfully associated to coronary artery disease (CAD). Eighty-eight patients were randomly selected from those who underwent coronary angiography from June 2010 to June 2011 after applying to the outpatient cardiology clinic in Gulhane Military Medical Academy. According to the results of angiographies, patients were classified into three groups as normal, non-critical (< 50% involvement in coronaries), and critical (≥ 50% involvement in coronaries). In addition to angiographic intervention, measurements of serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) concentrations, albumin and the other serum parameters were performed in all patients. The patient groups of CAD were balanced (28 critical cases, 30 non-critical cases and 30 normal cases). Mean age was 51.93 ± 9.3 (range 32-65) years and 19.3 per cent (n = 17) were females. Multiple linear regression analysis of all three liver function tests explained a significant portion of the variance, but adjusted r-squares were small (AST = 0.174, ALT = 0.242, albumin = 0.124). Albumin was significantly higher for patients with critical CAD than for patients with no CAD (beta = 3.205, p = 0.002). Non-critical CAD was not significantly different from no CAD for any of the dependent variables. Mean AST was significantly higher for patients taking aspirin (beta = 0.218, p = 0.049), as was mean ALT (beta = 0.264, p = 0.015). Alanine aminotransferase and AST may not be associated with angiographically determined coronary atherosclerosis. Albumin may be more sensitive to demonstrate the burden of atherosclerosis. These results indicate that the association between the liver function tests and coronary atherosclerosis may be more

  17. Thyroid Function Tests.

    ERIC Educational Resources Information Center

    Glover, Irving T.

    1979-01-01

    Describes two tests, T-4 and T-3, for hypothyroid based on the binding of the hormones by proteins. The tests were performed in courses for physicians, clinical chemists, laboratory technicians, and undergraduate science students by the individuals involved and on their own sera. These tests are commercially available in kit form. (GA)

  18. Advanced Techniques in Pulmonary Function Test Analysis Interpretation and Diagnosis

    PubMed Central

    Gildea, T.J.; Bell, C. William

    1980-01-01

    The Pulmonary Functions Analysis and Diagnostic System is an advanced clinical processing system developed for use at the Pulmonary Division, Department of Medicine at the University of Nebraska Medical Center. The system generates comparative results and diagnostic impressions for a variety of routine and specialized pulmonary functions test data. Routine evaluation deals with static lung volumes, breathing mechanics, diffusing capacity, and blood gases while specialized tests include lung compliance studies, small airways dysfunction studies and dead space to tidal volume ratios. Output includes tabular results of normal vs. observed values, clinical impressions and commentary and, where indicated, a diagnostic impression. A number of pulmonary physiological and state variables are entered or sampled (A to D) with periodic status reports generated for the test supervisor. Among the various physiological variables sampled are respiratory frequency, minute ventilation, oxygen consumption, carbon dioxide production, and arterial oxygen saturation.

  19. The twelve-flavor β-function and dilaton tests of the sextet scalar

    NASA Astrophysics Data System (ADS)

    Fodor, Zoltan; Holland, Kieran; Kuti, Julius; Nogradi, Daniel; Him Wong, Chik

    2018-03-01

    We discuss near-conformal gauge theories beyond the standard model (BSM) where interesting results on the twelve-flavor β-function of massless fermions in the fundamental representation of the SU(3) color gauge group and dilaton tests of the light scalar with two massless fermions in the two-index symmetric tensor (sextet) representation can be viewed as parts of the same BSM paradigm under investigation. The clear trend in the decreasing size of β-functions at fixed renormalized gauge coupling is interpreted as a first indicator how the conformal window (CW) is approached in correlation with emergent near-conformal light scalars. BSM model building close to the CW will be influenced by differing expectations on the properties of the emergent light 0++ scalar either as a σ-particle of chiral symmetry breaking (ΧS B), or as a dilaton of scale symmetry breaking. The twelve-flavor β-function emerges as closest to the CW, perhaps near-conformal, or perhaps with an infrared fixed point (IRFP) at some unexplored strong coupling inside the CW. It is premature to speculate on dilaton properties of the twelveflavor model since the near-conformal realization remains an open question. However, it is interesting and important to investigate dilaton tests of the light sextet scalar whose β-function is closest to the CW in the symmetry breaking phase and emerges as the leading candidate for dilaton tests of the light scalar. We report results from high precision analysis of the twelve-flavor β-function [1] refuting its published IRFP [2, 3]. We present our objections to recent claims [4, 5] for non-universal behavior of staggered fermions used in our analysis. We also report our first analysis of dilaton tests of the light 0++ scalar in the sextet model and comment on related post-conference developments. The dilaton test is the main thrust of this conference contribution including presentation #405 on the nf = 12 β-function and presentation #260 on dilaton tests of the

  20. Muscular exercise can cause highly pathological liver function tests in healthy men

    PubMed Central

    Pettersson, Jonas; Hindorf, Ulf; Persson, Paula; Bengtsson, Thomas; Malmqvist, Ulf; Werkström, Viktoria; Ekelund, Mats

    2008-01-01

    Aim To investigate the effect of intensive muscular exercise (weightlifting) on clinical chemistry parameters reflecting liver function in healthy men. Methods Fifteen healthy men, used to moderate physical activity not including weightlifting, performed an 1 h long weightlifting programme. Blood was sampled for clinical chemistry parameters [aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LD), gamma-glutamyl transferase (γGT), alkaline phosphatase (ALP), bilirubin, creatine kinase (CK) and myoglobin] at repeated intervals during 7 days postexercise and at a follow-up examination 10–12 days postexercise. Results Five out of eight studied clinical chemistry parameters (AST, ALT, LD, CK and myoglobin) increased significantly after exercise (P < 0.01) and remained increased for at least 7 days postexercise. Bilirubin, γGT and ALP remained within the normal range. Conclusion The liver function parameters, AST and ALT, were significantly increased for at least 7 days after the exercise. In addition, LD and, in particular, CK and myoglobin showed highly elevated levels. These findings highlight the importance of imposing restrictions on weightlifting prior to and during clinical studies. Intensive muscular exercise, e.g. weightlifting, should also be considered as a cause of asymptomatic elevations of liver function tests in daily clinical practice. What is already known about this subject The occurrence of idiosyncratic drug hepatotoxicity is a major problem in all phases of clinical drug development and the leading cause of postmarketing warnings and withdrawals.Physical exercise can result in transient elevations of liver function tests.There is no consensus in the literature on which forms of exercise may cause changes in liver function tests and to what extent. What this study adds Weightlifting results in profound increases in liver function tests in healthy men used to moderate physical activity, not including

  1. [Circulatory Function Tests for Home & Community Use.

    PubMed

    Shimetani, Naoto

    2016-05-01

    Currently, the main circulatory function-testing tools for home use are blood pressure monitors and elec- trocardiography devices. Just like blood pressure monitors that are already widespread for home use, some devices with an electrocardiographic function have recently become available for purchase for personal use by the general public. On the other hand, clinic equipment on loan from doctors to patients in need can perform circulatory function tests like 24-hour ambulatory blood pressure monitoring (ABPM), Holter monitoring, and real-time electrocardiography. We introduce the actual clinical usage of ABPM and real-time electro- cardiography, and discuss the usefulness of these procedures. ABPM uses a blood pressure measurement device worn on the body for 24 hours a day to measure blood pressure at regular intervals. This makes it possible to check blood pressure changes throughout the day in a way in which conventional home-use blood pressure monitors cannot, like during sleep. This method al- lows the identification of masked hypertension like early-morning and nocturnal hypertension, stress hyper- tension including workplace hypertension, and white coat hypertension that only occurs in the doctor's office. Under routine care, there are few opportunities to perform electrocardiography at the time a patient is experiencing symptoms. Now, real-time electrocardiography has begun to be used in routine care, and pa- tients can record an electrocardiogram by themselves anytime, anywhere, and send the data by telephone or the Internet for analysis and diagnosis. Transmission-capable electrocardiography devices can play an im- portant role in the event of dangerous symptoms like arrhythmia, angina, or acute myocardial infarction. The spread of ABPM and event heart monitors is likely to make the early treatment and prevention of stroke and heart disease possible. We are expecting rapid development in this field in the future.

  2. A simple behavioral test for locomotor function after brain injury in mice.

    PubMed

    Tabuse, Masanao; Yaguchi, Masae; Ohta, Shigeki; Kawase, Takeshi; Toda, Masahiro

    2010-11-01

    To establish a simple and reliable test for assessing locomotor function in mice with brain injury, we developed a new method, the rotarod slip test, in which the number of slips of the paralytic hind limb from a rotarod is counted. Brain injuries of different severity were created in adult C57BL/6 mice, by inflicting 1-point, 2-point and 4-point cryo-injuries. These mice were subjected to the rotarod slip test, the accelerating rotarod test and the elevated body swing test (EBST). Histological analyses were performed to assess the severity of the brain damage. Significant and consistent correlations between test scores and severity were observed for the rotarod slip test and the EBST. Only the rotarod slip test detected the mild hindlimb paresis in the acute and sub-acute phase after injury. Our results suggest that the rotarod slip test is the most sensitive and reliable method for assessing locomotor function after brain damage in mice. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Performance of exchange-correlation functionals in density functional theory calculations for liquid metal: A benchmark test for sodium

    NASA Astrophysics Data System (ADS)

    Han, Jeong-Hwan; Oda, Takuji

    2018-04-01

    The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.

  4. Performance of exchange-correlation functionals in density functional theory calculations for liquid metal: A benchmark test for sodium.

    PubMed

    Han, Jeong-Hwan; Oda, Takuji

    2018-04-14

    The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.

  5. Test-retest reliability of functional connectivity networks during naturalistic fMRI paradigms.

    PubMed

    Wang, Jiahui; Ren, Yudan; Hu, Xintao; Nguyen, Vinh Thai; Guo, Lei; Han, Junwei; Guo, Christine Cong

    2017-04-01

    Functional connectivity analysis has become a powerful tool for probing the human brain function and its breakdown in neuropsychiatry disorders. So far, most studies adopted resting-state paradigm to examine functional connectivity networks in the brain, thanks to its low demand and high tolerance that are essential for clinical studies. However, the test-retest reliability of resting-state connectivity measures is moderate, potentially due to its low behavioral constraint. On the other hand, naturalistic neuroimaging paradigms, an emerging approach for cognitive neuroscience with high ecological validity, could potentially improve the reliability of functional connectivity measures. To test this hypothesis, we characterized the test-retest reliability of functional connectivity measures during a natural viewing condition, and benchmarked it against resting-state connectivity measures acquired within the same functional magnetic resonance imaging (fMRI) session. We found that the reliability of connectivity and graph theoretical measures of brain networks is significantly improved during natural viewing conditions over resting-state conditions, with an average increase of almost 50% across various connectivity measures. Not only sensory networks for audio-visual processing become more reliable, higher order brain networks, such as default mode and attention networks, but also appear to show higher reliability during natural viewing. Our results support the use of natural viewing paradigms in estimating functional connectivity of brain networks, and have important implications for clinical application of fMRI. Hum Brain Mapp 38:2226-2241, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. Varying the valuating function and the presentable bank in computerized adaptive testing.

    PubMed

    Barrada, Juan Ramón; Abad, Francisco José; Olea, Julio

    2011-05-01

    In computerized adaptive testing, the most commonly used valuating function is the Fisher information function. When the goal is to keep item bank security at a maximum, the valuating function that seems most convenient is the matching criterion, valuating the distance between the estimated trait level and the point where the maximum of the information function is located. Recently, it has been proposed not to keep the same valuating function constant for all the items in the test. In this study we expand the idea of combining the matching criterion with the Fisher information function. We also manipulate the number of strata into which the bank is divided. We find that the manipulation of the number of items administered with each function makes it possible to move from the pole of high accuracy and low security to the opposite pole. It is possible to greatly improve item bank security with much fewer losses in accuracy by selecting several items with the matching criterion. In general, it seems more appropriate not to stratify the bank.

  7. A function approximation approach to anomaly detection in propulsion system test data

    NASA Technical Reports Server (NTRS)

    Whitehead, Bruce A.; Hoyt, W. A.

    1993-01-01

    Ground test data from propulsion systems such as the Space Shuttle Main Engine (SSME) can be automatically screened for anomalies by a neural network. The neural network screens data after being trained with nominal data only. Given the values of 14 measurements reflecting external influences on the SSME at a given time, the neural network predicts the expected nominal value of a desired engine parameter at that time. We compared the ability of three different function-approximation techniques to perform this nominal value prediction: a novel neural network architecture based on Gaussian bar basis functions, a conventional back propagation neural network, and linear regression. These three techniques were tested with real data from six SSME ground tests containing two anomalies. The basis function network trained more rapidly than back propagation. It yielded nominal predictions with, a tight enough confidence interval to distinguish anomalous deviations from the nominal fluctuations in an engine parameter. Since the function-approximation approach requires nominal training data only, it is capable of detecting unknown classes of anomalies for which training data is not available.

  8. Improving ATLAS grid site reliability with functional tests using HammerCloud

    NASA Astrophysics Data System (ADS)

    Elmsheuser, Johannes; Legger, Federica; Medrano Llamas, Ramon; Sciacca, Gianfranco; van der Ster, Dan

    2012-12-01

    With the exponential growth of LHC (Large Hadron Collider) data in 2011, and more coming in 2012, distributed computing has become the established way to analyse collider data. The ATLAS grid infrastructure includes almost 100 sites worldwide, ranging from large national computing centers to smaller university clusters. These facilities are used for data reconstruction and simulation, which are centrally managed by the ATLAS production system, and for distributed user analysis. To ensure the smooth operation of such a complex system, regular tests of all sites are necessary to validate the site capability of successfully executing user and production jobs. We report on the development, optimization and results of an automated functional testing suite using the HammerCloud framework. Functional tests are short lightweight applications covering typical user analysis and production schemes, which are periodically submitted to all ATLAS grid sites. Results from those tests are collected and used to evaluate site performances. Sites that fail or are unable to run the tests are automatically excluded from the PanDA brokerage system, therefore avoiding user or production jobs to be sent to problematic sites.

  9. Psychometric evaluation of the Chinese version of short-form Test of Functional Health Literacy in Adolescents.

    PubMed

    Chang, Li-Chun; Hsieh, Pei-Lin; Liu, Chieh-Hsing

    2012-09-01

    The purpose of this study is to develop and evaluate the psychometric properties of the Chinese version of short-form Test of Functional Health Literacy in Adolescents. Assessing health literacy is vital to design health education programme; however, there are no measurement tools exist for use specifically in Chinese adolescents. A non-experimental design was used to test the psychometric properties of the Test of Functional Health Literacy in Adolescents. The short-form Test of Functional Health Literacy in Adolescents was translated and back translated into a Chinese language version. Thirty high school students were recruited to validate the scenario of Test of Functional Health Literacy in Adolescents. Based on the multiple-stage stratified random sampling method, 300 high school students from four counties in Taiwan were invited to participate in this study to evaluate the psychometric properties of Test of Functional Health Literacy in Adolescents. The Functional Health Literacy in Adolescents had good internal consistency reliability and excellent test-retest reliability. Confirmatory factor analysis resulted in a one-factor solution. Contrary to the original version of the Test of Functional Health Literacy in Adolescents, the findings revealed that the 36-item, one-factor model for the Test of Functional Health Literacy in Adolescents is the best-fit model. This is a suitable instrument to assess health literacy levels in Chinese adolescents before health education programmes can be appropriately planned, implemented and evaluated. © 2012 Blackwell Publishing Ltd.

  10. Work-related measures of physical and behavioral health function: Test-retest reliability.

    PubMed

    Marino, Molly Elizabeth; Meterko, Mark; Marfeo, Elizabeth E; McDonough, Christine M; Jette, Alan M; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K; Brandt, Diane E; Chan, Leighton

    2015-10-01

    The Work Disability Functional Assessment Battery (WD-FAB), developed for potential use by the US Social Security Administration to assess work-related function, currently consists of five multi-item scales assessing physical function and four multi-item scales assessing behavioral health function; the WD-FAB scales are administered as Computerized Adaptive Tests (CATs). The goal of this study was to evaluate the test-retest reliability of the WD-FAB Physical Function and Behavioral Health CATs. We administered the WD-FAB scales twice, 7-10 days apart, to a sample of 376 working age adults and 316 adults with work-disability. Intraclass correlation coefficients were calculated to measure the consistency of the scores between the two administrations. Standard error of measurement (SEM) and minimal detectable change (MDC90) were also calculated to measure the scales precision and sensitivity. For the Physical Function CAT scales, the ICCs ranged from 0.76 to 0.89 in the working age adult sample, and 0.77-0.86 in the sample of adults with work-disability. ICCs for the Behavioral Health CAT scales ranged from 0.66 to 0.70 in the working age adult sample, and 0.77-0.80 in the adults with work-disability. The SEM ranged from 3.25 to 4.55 for the Physical Function scales and 5.27-6.97 for the Behavioral Health function scales. For all scales in both samples, the MDC90 ranged from 7.58 to 16.27. Both the Physical Function and Behavioral Health CATs of the WD-FAB demonstrated good test-retest reliability in adults with work-disability and general adult samples, a critical requirement for assessing work related functioning in disability applicants and in other contexts. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Work-related measures of Physical and Behavioral Health Function: Test-Retest Reliability

    PubMed Central

    Marino, Molly Elizabeth; Meterko, Mark; Marfeo, Elizabeth E.; McDonough, Christine M.; Jette, Alan M.; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K.; Brandt, Diane E.; Chan, Leighton

    2015-01-01

    Background The Work Disability Functional Assessment Battery (WD-FAB), developed for potential use by the US Social Security Administration to assess work-related function, currently consists of five multi-item scales assessing physical function and four multi-item scales assessing behavioral health function; the WD-FAB scales are administered as Computerized Adaptive Tests (CATs). Objective The goal of this study was to evaluate the test-retest reliability of the WD-FAB Physical Function and Behavioral Health CATs. Methods We administered the WD-FAB scales twice, 7–10 days apart, to a sample of 376 working age adults and 316 adults with work-disability. Intraclass correlation coefficients were calculated to measure the consistency of the scores between the two administrations. Standard error of measurement (SEM) and minimal detectable change (MDC90) were also calculated to measure the scales precision and sensitivity. Results For the Physical Function CAT scales, the ICCs ranged from 0.76–0.89 in the working age adult sample, and 0.77–0.86 in the sample of adults with work-disability. ICCs for the Behavioral Health CAT scales ranged from 0.66–0.70 in the working age adult sample, and 0.77–0.80 in the adults with work-disability. The SEM ranged from 3.25–4.55 for the Physical Function scales and 5.27–6.97 for the Behavioral Health function scales. For all scales in both samples, the MDC90 ranged from 7.58–16.27. Conclusion Both the Physical Function and Behavioral Health CATs of the WD-FAB demonstrated good test-retest reliability in adults with work-disability and general adult samples, a critical requirement for assessing work related functioning in disability applicants and in other contexts. PMID:25991419

  12. Differential item functioning analysis of the Vanderbilt Expertise Test for cars

    PubMed Central

    Lee, Woo-Yeol; Cho, Sun-Joo; McGugin, Rankin W.; Van Gulick, Ana Beth; Gauthier, Isabel

    2015-01-01

    The Vanderbilt Expertise Test for cars (VETcar) is a test of visual learning for contemporary car models. We used item response theory to assess the VETcar and in particular used differential item functioning (DIF) analysis to ask if the test functions the same way in laboratory versus online settings and for different groups based on age and gender. An exploratory factor analysis found evidence of multidimensionality in the VETcar, although a single dimension was deemed sufficient to capture the recognition ability measured by the test. We selected a unidimensional three-parameter logistic item response model to examine item characteristics and subject abilities. The VETcar had satisfactory internal consistency. A substantial number of items showed DIF at a medium effect size for test setting and for age group, whereas gender DIF was negligible. Because online subjects were on average older than those tested in the lab, we focused on the age groups to conduct a multigroup item response theory analysis. This revealed that most items on the test favored the younger group. DIF could be more the rule than the exception when measuring performance with familiar object categories, therefore posing a challenge for the measurement of either domain-general visual abilities or category-specific knowledge. PMID:26418499

  13. Differential item functioning analysis of the Vanderbilt Expertise Test for cars.

    PubMed

    Lee, Woo-Yeol; Cho, Sun-Joo; McGugin, Rankin W; Van Gulick, Ana Beth; Gauthier, Isabel

    2015-01-01

    The Vanderbilt Expertise Test for cars (VETcar) is a test of visual learning for contemporary car models. We used item response theory to assess the VETcar and in particular used differential item functioning (DIF) analysis to ask if the test functions the same way in laboratory versus online settings and for different groups based on age and gender. An exploratory factor analysis found evidence of multidimensionality in the VETcar, although a single dimension was deemed sufficient to capture the recognition ability measured by the test. We selected a unidimensional three-parameter logistic item response model to examine item characteristics and subject abilities. The VETcar had satisfactory internal consistency. A substantial number of items showed DIF at a medium effect size for test setting and for age group, whereas gender DIF was negligible. Because online subjects were on average older than those tested in the lab, we focused on the age groups to conduct a multigroup item response theory analysis. This revealed that most items on the test favored the younger group. DIF could be more the rule than the exception when measuring performance with familiar object categories, therefore posing a challenge for the measurement of either domain-general visual abilities or category-specific knowledge.

  14. [Assessment of the horizontal semicircular canal function after cochlear implantation by video head impulse test and caloric test].

    PubMed

    Zeng, Jie; Huang, Hong Ming; Wang, Xiao Qian; Zhong, Kai Bang; Wu, Pei Na

    2018-01-20

    Objective: To analyze the functional change of horizontal semicircular canals after cochlear implantation. Method: Eighteen patients were enrolled in this study.Their vestibular function was evaluated by using the caloric test and video head impulse test before and one week,one month after CI surgery,respectively.The unilateral weakness(UW),slow phase velocity(SPV)in caloric test and gain in video head impulse test(vHIT-G)were observed.Caloric test was abnormal when UW>25% or SPV mean<6°/s,while vHIT was abnormal when vHIT-G<0.8. Result: The SPV of the implanted ear were[(10.36±8.01)°/s;(14.77±14.24)°/s]pre-operatively,[(6.45±7.52)°/s;(5.14±4.67)°/s]1 week post-operatively and[(6.05±3.86)°/s;(6.27±4.17)°/s]1 month post-operatively.Statistically significant difference( P <0.05)was found between pre-and post-operative period.The vHIT-G of the implanted ear were(0.73±0.33)pre-operatively,(0.65±0.32)1 week post-operatively and(0.71±0.36)1 month post-operatively.There was no statistically significant difference of vHIT-G between preand post-operative period( P (pre-operative/1 week post-operative)=0.084, P (pre-operative/1 month post-operative)=0.679).Four patients presented with vertigo and one of them manifested slight unsteadiness post-operatively.All symptoms resolved within 7 days.These symptoms had no correlate with age,gender,implantedear and results of vestibular test. Conclusion: Cochlear implantation can affect the horizontal semicircular canal function,and the video head impulse test and caloric test should be used in a complementary fashion.

  15. Sensitivity and Specificity of Eustachian Tube Function Tests in Adults

    PubMed Central

    Doyle, William J.; Swarts, J. Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M.

    2013-01-01

    Objective Determine if Eustachian Tube (ET) function (ETF) tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and define the inter-relatedness of ETF test parameters. Methods ETF was evaluated using the Forced-Response, Inflation-Deflation, Valsalva and Sniffing tests in 15 control ears of adult subjects after unilateral myringotomy (Group I) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (Group II). Data were analyzed using logistic regression including each parameter independently and then a step-down Discriminant Analysis including all ETF test parameters to predict group assignment. Factor Analysis operating over all parameters was used to explore relatedness. Results The Discriminant Analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency and % positive pressure equilibrated) that together correctly assigned ears to Group II at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters, the first had negative loadings of the ETF structural parameters, the second had positive loadings of the muscle-assisted ET opening parameters and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. Discussion These results show that ETF tests can correctly assign individual ears to physician-diagnosed ETD with high sensitivity and specificity and that ETF test parameters can be grouped into structural-functional categories. PMID:23868429

  16. DVA as a Diagnostic Test for Vestibulo-Ocular Reflex Function

    NASA Technical Reports Server (NTRS)

    Wood, Scott J.; Appelbaum, Meghan

    2010-01-01

    The vestibulo-ocular reflex (VOR) stabilizes vision on earth-fixed targets by eliciting eyes movements in response to changes in head position. How well the eyes perform this task can be functionally measured by the dynamic visual acuity (DVA) test. We designed a passive, horizontal DVA test to specifically study the acuity and reaction time when looking in different target locations. Visual acuity was compared among 12 subjects using a standard Landolt C wall chart, a computerized static (no rotation) acuity test and dynamic acuity test while oscillating at 0.8 Hz (+/-60 deg/s). In addition, five trials with yaw oscillation randomly presented a visual target in one of nine different locations with the size and presentation duration of the visual target varying across trials. The results showed a significant difference between the static and dynamic threshold acuities as well as a significant difference between the visual targets presented in the horizontal plane versus those in the vertical plane when comparing accuracy of vision and reaction time of the response. Visual acuity increased proportional to the size of the visual target and increased between 150 and 300 msec duration. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of rotation. This DVA test could be used as a functional diagnostic test for visual-vestibular and neuro-cognitive impairments by assessing both accuracy and reaction time to acquire visual targets.

  17. Survey of clinical infant lung function testing practices.

    PubMed

    Peterson-Carmichael, Stacey L; Rosenfeld, Margaret; Ascher, Simon B; Hornik, Christoph P; Arets, H G M; Davis, Stephanie D; Hall, Graham L

    2014-02-01

    Data supporting the clinical use of infant lung function (ILF) tests are limited making the interpretation of clinical ILF measures difficult. To evaluate current ILF testing practices and to survey users regarding the indications, limitations and perceived clinical benefits of ILF testing. We created a 26-item survey hosted on the European Respiratory Society (ERS) website between January and May 2010. Notifications were sent to members of the ERS, American Thoracic Society and the Asian Pacific Society of Respirology. Responses were sought from ILF laboratory directors and pediatric respirologists. The survey assessed the clinical indications, patient populations, equipment and reference data used, and perceived limitations of ILF testing. We received 148 responses with 98 respondents having ILF equipment and performing testing in a clinical capacity. Centers in North America were less likely to perform ≥50 studies/year than centers in Europe or other continents (13% vs. 41%). Most respondents used ILF data to either "start a new therapy" (78%) or "help decide about initiation of further diagnostic workup such as bronchoscopy, chest CT or serological testing" (69%). Factors reported as limiting clinical ILF testing were need for sedation, uncertainty regarding clinical impact of study results and time intensive nature of the study. Clinical practices associated with ILF testing vary significantly; centers that perform more studies are more likely to use the results for clinical purposes and decision making. The future of ILF testing is uncertain in the face of the limitations perceived by the survey respondents. © 2013 Wiley Periodicals, Inc.

  18. Outcomes of anatomical vs. functional testing for coronary artery disease : Lessons from the PROMISE trial.

    PubMed

    Shah, R; Foldyna, B; Hoffmann, U

    2016-08-01

    The development of coronary artery disease (CAD) is a major, final common pathway in heart disease worldwide. With a rise in stress testing and increased scrutiny on cost-effectiveness and radiation exposure in medical imaging, a focus on the relative merits of anatomic versus functional characterization of CAD has emerged. In this context, coronary computed tomography angiography (CCTA) is a noninvasive alternative to functional testing as a first-line test for CAD detection but is complimentary in its nature. Here, we discuss the design, results, and implications of the PROMISE trial, a randomized comparative effectiveness study of 10,003 patients across 193 sites in the United States and Canada comparing the prognostic and diagnostic power of CCTA and standard stress testing. Specifically, we discuss the safety (e. g., contrast, radiation exposure) of CCTA versus functional testing in CAD, the need for improved selection for noninvasive testing, the frequency of downstream testing after anatomic or functional imaging, the use of imaging results in clinical management, and novel modalities of CAD risk determination using CCTA. PROMISE demonstrated that in a real-world, low-to-intermediate risk patient population referred to noninvasive testing for CAD, both CCTA and functional testing approaches have similar clinical, economic, and safety-based outcomes. We conclude with open questions in CAD imaging, specifically as they pertain to the utilization of CCTA.

  19. Impairment in Occupational Functioning and Adult ADHD: The Predictive Utility of Executive Function (EF) Ratings Versus EF Tests

    PubMed Central

    Barkley, Russell A.; Murphy, Kevin R.

    2010-01-01

    Attention deficit hyperactivity disorder (ADHD) is associated with deficits in executive functioning (EF). ADHD in adults is also associated with impairments in major life activities, particularly occupational functioning. We investigated the extent to which EF deficits assessed by both tests and self-ratings contributed to the degree of impairment in 11 measures involving self-reported occupational problems, employer reported workplace adjustment, and clinician rated occupational adjustment. Three groups of adults were recruited as a function of their severity of ADHD: ADHD diagnosis (n = 146), clinical controls self-referring for ADHD but not diagnosed with it (n = 97), and community controls (n = 109). Groups were combined and regression analyses revealed that self-ratings of EF were significantly predictive of impairments in all 11 measures of occupational adjustment. Although several tests of EF also did so, they contributed substantially less than did the EF ratings, particularly when analyzed jointly with the ratings. We conclude that EF deficits contribute to the impairments in occupational functioning that occur in conjunction with adult ADHD. Ratings of EF in daily life contribute more to such impairments than do EF tests, perhaps because, as we hypothesize, each assesses a different level in the hierarchical organization of EF as a meta-construct. PMID:20197297

  20. AN EVALUATION OF HEURISTICS FOR THRESHOLD-FUNCTION TEST-SYNTHESIS,

    DTIC Science & Technology

    Linear programming offers the most attractive procedure for testing and obtaining optimal threshold gate realizations for functions generated in...The design of the experiments may be of general interest to students of automatic problem solving; the results should be of interest in threshold logic and linear programming. (Author)

  1. Pulmonary Function Tests

    MedlinePlus

    ... clinical research. More Information Related Health Topics Asbestos-Related Lung Diseases Asthma Chest X-Ray COPD Cough Electrocardiogram Heart Failure How the Lungs Work Idiopathic Pulmonary Fibrosis Oxygen Therapy Sarcoidosis Stress Testing NHLBI Resources Taking a Spirometry Test Building ...

  2. Design and test of an automated version of the modified Jebsen test of hand function using Microsoft Kinect.

    PubMed

    Simonsen, Daniel; Nielsen, Ida F; Spaich, Erika G; Andersen, Ole K

    2017-05-02

    The present paper describes the design and evaluation of an automated version of the Modified Jebsen Test of Hand Function (MJT) based on the Microsoft Kinect sensor. The MJT was administered twice to 11 chronic stroke subjects with varying degrees of hand function deficits. The test times of the MJT were evaluated manually by a therapist using a stopwatch, and automatically using the Microsoft Kinect sensor. The ground truth times were assessed based on inspection of the video-recordings. The agreement between the methods was evaluated along with the test-retest performance. The results from Bland-Altman analysis showed better agreement between the ground truth times and the automatic MJT time evaluations compared to the agreement between the ground truth times and the times estimated by the therapist. The results from the test-retest performance showed that the subjects significantly improved their performance in several subtests of the MJT, indicating a practice effect. The results from the test showed that the Kinect can be used for automating the MJT.

  3. An integrative method for testing form–function linkages and reconstructed evolutionary pathways of masticatory specialization

    PubMed Central

    Tseng, Z. Jack; Flynn, John J.

    2015-01-01

    Morphology serves as a ubiquitous proxy in macroevolutionary studies to identify potential adaptive processes and patterns. Inferences of functional significance of phenotypes or their evolution are overwhelmingly based on data from living taxa. Yet, correspondence between form and function has been tested in only a few model species, and those linkages are highly complex. The lack of explicit methodologies to integrate form and function analyses within a deep-time and phylogenetic context weakens inferences of adaptive morphological evolution, by invoking but not testing form–function linkages. Here, we provide a novel approach to test mechanical properties at reconstructed ancestral nodes/taxa and the strength and direction of evolutionary pathways in feeding biomechanics, in a case study of carnivorous mammals. Using biomechanical profile comparisons that provide functional signals for the separation of feeding morphologies, we demonstrate, using experimental optimization criteria on estimation of strength and direction of functional changes on a phylogeny, that convergence in mechanical properties and degree of evolutionary optimization can be decoupled. This integrative approach is broadly applicable to other clades, by using quantitative data and model-based tests to evaluate interpretations of function from morphology and functional explanations for observed macroevolutionary pathways. PMID:25994295

  4. Thyroid function testing in neonates born to women with hypothyroidism.

    PubMed

    McGovern, Matthew; Reyani, Zahra; O'Connor, Pamela; White, Martin; Miletin, Jan

    2016-12-01

    Our aim was to assess the utility of serum thyroxine and thyroid stimulating hormone performed at 10-14 days of life in diagnosing congenital hypothyroidism (CH) in babies born to mothers with hypothyroidism. This was a retrospective study of all babies born in a tertiary referral centre for neonatology over a 12-month period. Infants who had thyroid function testing (TFT) checked at 10-14 days of life because of maternal hypothyroidism during the period of study were included. The results of the newborn bloodspot and day 10-14 TFT were recorded along with whether or not patients were subsequently treated. Of the 319 patients included in the study, only two patients were found to have CH and in both cases the newborn blood spot had been abnormal. No extra cases of CH were detected from the thyroid test at 10-14 days and this practice should be discontinued due to the robust nature of existing newborn screening programmes. What is Known: • Congenital hypothyroidism(CH) is the commonest preventable cause of childhood intellectual impairment. • Family history of hypothyroidism has been implicated as a risk factor for CH. • CH has formed part of newborn screening since the 1970s. What is New: • There is no research recommending thyroid function testing at 10-14 days of life to detect CH in neonates born to mothers with hypothyroidism. • Thyroid function testing at 10-14 days of life does not improve diagnostic yield for CH in babies born to mothers with hypothyroidism. • Newborn blood spot remains the mainstay for accurate and timely diagnosis of CH.

  5. The Jebsen Taylor Test of Hand Function: A Pilot Test-Retest Reliability Study in Typically Developing Children.

    PubMed

    Reedman, Sarah Elizabeth; Beagley, Simon; Sakzewski, Leanne; Boyd, Roslyn N

    2016-08-01

    The aim of this pilot study was to evaluate reproducibility of the Jebsen Taylor Test of Hand Function (JTTHF) in children. Eighty-seven typically developing children 5 to 10 years old were included from five Outside School Hours Care centers in the Greater Brisbane Region, Australia. Hand function was assessed on two occasions with a modified JTTHF, then reproducibility was assessed using Intraclass Correlation Coefficient (ICC [3,1]) and the Standard Error of Measurement (SEM). Total scores for male and female children were not significantly different. Five-year-old children were significantly different to all other age groups and were excluded from further analysis. Results for 71 children, 6 to 10 years old were analyzed (mean age 8.31 years (SD 1.32); 33 males). Test-retest reliability for total scores on the dominant and nondominant hands were ICC 0.74 (95% CI 0.61, 0.83) and ICC 0.72 (95% CI 0.59, 0.82), respectively. 'Writing' and 'Simulated Feeding' subtests demonstrated poor reproducibility. The Smallest Real Difference was 5.09 seconds for total score on the dominant hand. Findings indicate good test-retest reliability for the JTTHF total score to measure hand function in typically developing children aged 6 to 10 years.

  6. Functional Task Test: 1. Sensorimotor changes Associated with Postflight Alterations in Astronaut Functional Task Performance

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Arzeno, N. H.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Platts, S. H.; Peters, B. T.; hide

    2011-01-01

    Space flight is known to cause alterations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. This presentation will focus on the sensorimotor contributions to postflight functional performance.

  7. The Role of Tests in Assessing Intellectual Functioning of Children with Special Needs.

    ERIC Educational Resources Information Center

    Mearig, Judith S.

    1981-01-01

    Various testing methods have been developed to assess the intellectual functioning of children with learning disabilities, but testing is only one tool in the comprehensive process of assessment. The alternatives to relying exclusively on intelligence testing include ability tests, individual education plans, and beginning the teaching/programing…

  8. Validation of Cardiovascular Parameters During NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, Steven H.

    2008-01-01

    Microgravity-induced physiological changes, including cardiovascular deconditioning may impair crewmembers f capabilities during exploration missions on the Moon and Mars. The Functional Task Test (FTT), which will be used to assess task performance in short and long duration astronauts, consists of 7 functional tests to evaluate crewmembers f ability to perform activities to be conducted in a partial-gravity environment or following an emergency landing on Earth. The Recovery from Fall/Stand Test (RFST) tests both the subject fs ability to get up from a prone position and orthostatic intolerance. PURPOSE: Crewmembers have never become presyncopal in the first 3 min of quiet stand, yet it is unknown whether 3 min is long enough to cause similar heart rate fluctuations to a 5-min stand. The purpose of this study was to validate and test the reliability of heart rate variability (HRV) analysis of a 3-min quiet stand. METHODS: To determine the validity of using 3 vs. 5-min of standing to assess HRV, 7 healthy subjects remained in a prone position for 2 min, stood up quickly and stood quietly for 6 min. ECG and continuous blood pressure data were recorded. Mean R-R interval and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the complete FTT on separate days, including the RFST with a 3-min stand test. Analysis of variance (ANOVA) was performed on the HRV measures. RESULTS: Spectral HRV measures reflecting autonomic activity were not different (p>0.05) during the 0-3 and 0-5 min segment (mean R-R interval: 738+/-74 ms, 728+/-69 ms; low frequency to high frequency ratio: 6.5+/-2.2, 7.7+/-2.7; normalized high frequency: 0.19+/-0.03, 0.18+/-0.04). The average coefficient of variation for mean R-R interval, systolic and diastolic blood pressures

  9. Sensitivity and specificity of eustachian tube function tests in adults.

    PubMed

    Doyle, William J; Swarts, J Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M

    2013-07-01

    The study demonstrates the utility of eustachian tube (ET) function (ETF) test results for accurately assigning ears to disease state. To determine if ETF tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and to define the interrelatedness of ETF test parameters. Through use of the forced-response, inflation-deflation, Valsalva, and sniffing tests, ETF was evaluated in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). Data were analyzed using logistic regression including each parameter independently and then a step-down discriminant analysis including all ETF test parameters to predict group assignment. Factor analysis operating over all parameters was used to explore relatedness. ETF testing. ETF parameters for the forced response, inflation-deflation, Valsalva, and sniffing tests measured in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). The discriminant analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency, and percentage of positive pressure equilibrated) that together correctly assigned ears to group 2 at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters: the first had negative loadings of the ETF structural parameters; the second had positive loadings of the muscle-assisted ET opening parameters; and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. These results show that ETF tests can correctly assign individual ears to

  10. On testing an unspecified function through a linear mixed effects model with multiple variance components

    PubMed Central

    Wang, Yuanjia; Chen, Huaihou

    2012-01-01

    Summary We examine a generalized F-test of a nonparametric function through penalized splines and a linear mixed effects model representation. With a mixed effects model representation of penalized splines, we imbed the test of an unspecified function into a test of some fixed effects and a variance component in a linear mixed effects model with nuisance variance components under the null. The procedure can be used to test a nonparametric function or varying-coefficient with clustered data, compare two spline functions, test the significance of an unspecified function in an additive model with multiple components, and test a row or a column effect in a two-way analysis of variance model. Through a spectral decomposition of the residual sum of squares, we provide a fast algorithm for computing the null distribution of the test, which significantly improves the computational efficiency over bootstrap. The spectral representation reveals a connection between the likelihood ratio test (LRT) in a multiple variance components model and a single component model. We examine our methods through simulations, where we show that the power of the generalized F-test may be higher than the LRT, depending on the hypothesis of interest and the true model under the alternative. We apply these methods to compute the genome-wide critical value and p-value of a genetic association test in a genome-wide association study (GWAS), where the usual bootstrap is computationally intensive (up to 108 simulations) and asymptotic approximation may be unreliable and conservative. PMID:23020801

  11. On testing an unspecified function through a linear mixed effects model with multiple variance components.

    PubMed

    Wang, Yuanjia; Chen, Huaihou

    2012-12-01

    We examine a generalized F-test of a nonparametric function through penalized splines and a linear mixed effects model representation. With a mixed effects model representation of penalized splines, we imbed the test of an unspecified function into a test of some fixed effects and a variance component in a linear mixed effects model with nuisance variance components under the null. The procedure can be used to test a nonparametric function or varying-coefficient with clustered data, compare two spline functions, test the significance of an unspecified function in an additive model with multiple components, and test a row or a column effect in a two-way analysis of variance model. Through a spectral decomposition of the residual sum of squares, we provide a fast algorithm for computing the null distribution of the test, which significantly improves the computational efficiency over bootstrap. The spectral representation reveals a connection between the likelihood ratio test (LRT) in a multiple variance components model and a single component model. We examine our methods through simulations, where we show that the power of the generalized F-test may be higher than the LRT, depending on the hypothesis of interest and the true model under the alternative. We apply these methods to compute the genome-wide critical value and p-value of a genetic association test in a genome-wide association study (GWAS), where the usual bootstrap is computationally intensive (up to 10(8) simulations) and asymptotic approximation may be unreliable and conservative. © 2012, The International Biometric Society.

  12. The partial coherence modulation transfer function in testing lithography lens

    NASA Astrophysics Data System (ADS)

    Huang, Jiun-Woei

    2018-03-01

    Due to the lithography demanding high performance in projection of semiconductor mask to wafer, the lens has to be almost free in spherical and coma aberration, thus, in situ optical testing for diagnosis of lens performance has to be established to verify the performance and to provide the suggesting for further improvement of the lens, before the lens has been build and integrated with light source. The measurement of modulation transfer function of critical dimension (CD) is main performance parameter to evaluate the line width of semiconductor platform fabricating ability for the smallest line width of producing tiny integrated circuits. Although the modulation transfer function (MTF) has been popularly used to evaluation the optical system, but in lithography, the contrast of each line-pair is in one dimension or two dimensions, analytically, while the lens stand along in the test bench integrated with the light source coherent or near coherent for the small dimension near the optical diffraction limit, the MTF is not only contributed by the lens, also by illumination of platform. In the study, the partial coherence modulation transfer function (PCMTF) for testing a lithography lens is suggested by measuring MTF in the high spatial frequency of in situ lithography lens, blended with the illumination of partial and in coherent light source. PCMTF can be one of measurement to evaluate the imperfect lens of lithography lens for further improvement in lens performance.

  13. Functional Testing Airborne Radars

    DTIC Science & Technology

    1981-03-27

    recorded, and presented in accordance with this TOP? Yes No Comment : 2. Were the facilities, test equipment, instrumentation, and support accommo- dations...adequate to accomplish the test objectives? Yes No Comment : 3. Have all data collected been reviewed for correctness and completeness? Yes No ... Comment : 4. Were the test results compromised in any way due to insufficient test planning? Yes No . Comment : 5. Were the test results compromised in any

  14. Spaceflight-induced cardiovascular changes and recovery during NASA's Functional Task Test

    NASA Astrophysics Data System (ADS)

    Arzeno, Natalia M.; Stenger, Michael B.; Bloomberg, Jacob J.; Platts, Steven H.

    2013-11-01

    Microgravity-induced physiologic changes could impair a crewmember's performance upon return to a gravity environment. The Functional Task Test aims to correlate these physiologic alterations with changes in performance during mission-critical tasks. In this study, we evaluated spaceflight-induced cardiovascular changes during 11 functional tasks in 7 Shuttle astronauts before spaceflight, on landing day, and 1, 6, and 30 days after landing. Mean heart rate was examined during each task and autonomic activity was approximated by heart rate variability during the Recovery from Fall/Stand Test, a 2-min prone rest followed by a 3-min stand. Heart rate was increased on landing day during all of the tasks, and remained elevated 6 days after landing during 6 of the 11 tasks. Parasympathetic modulation was diminished and sympathovagal balance was increased on landing day. Additionally, during the stand test 6 days after landing, parasympathetic modulation remained suppressed and heart rate remained elevated compared to preflight levels. Heart rate and autonomic activity were not different from preflight levels 30 days after landing. We detected changes in heart rate and autonomic activity during a 3-min stand and a variety of functional tasks, where cardiovascular deconditioning was still evident 6 days after returning from short-duration spaceflight. The delayed recovery times for heart rate and parasympathetic modulation indicate the necessity of assessing functional performance after long-duration spaceflight to ensure crew health and safety.

  15. 75 FR 50853 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... airplanes. 1. Function and Reliability Testing. Flight tests: In place of 14 CFR 21.35(b)(2), the following...; Function and Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final special... to CAR part 3 became effective January 15, 1951, and deleted the service test requirements in Section...

  16. A computer vision based candidate for functional balance test.

    PubMed

    Nalci, Alican; Khodamoradi, Alireza; Balkan, Ozgur; Nahab, Fatta; Garudadri, Harinath

    2015-08-01

    Balance in humans is a motor skill based on complex multimodal sensing, processing and control. Ability to maintain balance in activities of daily living (ADL) is compromised due to aging, diseases, injuries and environmental factors. Center for Disease Control and Prevention (CDC) estimate of the costs of falls among older adults was $34 billion in 2013 and is expected to reach $54.9 billion in 2020. In this paper, we present a brief review of balance impairments followed by subjective and objective tools currently used in clinical settings for human balance assessment. We propose a novel computer vision (CV) based approach as a candidate for functional balance test. The test will take less than a minute to administer and expected to be objective, repeatable and highly discriminative in quantifying ability to maintain posture and balance. We present an informal study with preliminary data from 10 healthy volunteers, and compare performance with a balance assessment system called BTrackS Balance Assessment Board. Our results show high degree of correlation with BTrackS. The proposed system promises to be a good candidate for objective functional balance tests and warrants further investigations to assess validity in clinical settings, including acute care, long term care and assisted living care facilities. Our long term goals include non-intrusive approaches to assess balance competence during ADL in independent living environments.

  17. Single-legged Hop Tests as Predictors of Self-reported Knee Function After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Logerstedt, David; Grindem, Hege; Lynch, Andrew; Eitzen, Ingrid; Engebretsen, Lars; Risberg, May Arna; Axe, Michael J.; Snyder-Mackler, Lynn

    2012-01-01

    Background Single-legged hop tests are commonly used functional performance measures that can capture limb asymmetries in patients after anterior cruciate ligament (ACL) reconstruction. Hop tests hold potential as predictive factors of self-reported knee function in individuals after ACL reconstruction. Hypothesis Single-legged hop tests conducted preoperatively would not and 6 months after ACL reconstruction would predict self-reported knee function (International Knee Documentation Committee [IKDC] 2000) 1 year after ACL reconstruction. Study Design Cohort study (prognosis); Level of evidence, 2. Methods One hundred twenty patients who were treated with ACL reconstruction performed 4 single-legged hop tests preoperatively and 6 months after ACL reconstruction. Self-reported knee function within normal ranges was defined as IKDC 2000 scores greater than or equal to the age- and sex-specific normative 15th percentile score 1 year after surgery. Logistic regression analyses were performed to identify predictors of self-reported knee function within normal ranges. The area under the curve (AUC) from receiver operating characteristic curves was used as a measure of discriminative accuracy. Results Eighty-five patients completed single-legged hop tests 6 months after surgery and the 1-year follow-up with 68 patients classified as having self-reported knee function within normal ranges 1 year after reconstruction. The crossover hop and 6-m timed hop limb symmetry index (LSI) 6 months after ACL reconstruction were the strongest individual predictors of self-reported knee function (odds ratio, 1.09 and 1.10) and the only 2 tests in which the confidence intervals of the discriminatory accuracy (AUC) were above 0.5 (AUC = 0.68). Patients with knee function below normal ranges were over 5 times more likely of having a 6-m timed hop LSI lower than the 88% cutoff than those with knee function within normal ranges. Patients with knee function within normal ranges were 4 times

  18. Development and testing of the Test of Functional Health Literacy in Dentistry (TOFHLiD).

    PubMed

    Gong, Debra A; Lee, Jessica Y; Rozier, R Gary; Pahel, Bhavna T; Richman, Julia A; Vann, William F

    2007-01-01

    This study aims to evaluate the reliability and validity of the Test of Functional Health Literacy in Dentistry (TOFHLiD), a new instrument to measure functional oral health literacy. TOFHLiD uses text passages and prompts related to fluoride use and access to care to assess reading comprehension and numerical ability. Parents of pediatric dental patients (n = 102) were administered TOFHLiD, a medical literacy comprehension test (TOFHLA), and two word recognition tests [Rapid Estimate of Adult Literacy in Dentistry (REALD), Rapid Estimate of Adult Literacy in Medicine (REALM)]. This design provided assessments of dental and medical health literacy by all subjects, both measured with two different methods (reading/numeracy ability and word recognition). Construct validity of TOFHLiD was assessed by entering the correlation coefficients for all pairwise comparisons of literacy instruments into a multitrait-multimethod matrix. Internal reliability of TOFHLiD was assessed with Cronbach's alpha. Criterion-related predictive validity was tested by associations between the TOFHLiD scores and the three measures of oral health in multivariate regression analyses. The correlation coefficient for TOFHLiD and REALD-99 scores (monotrait-heteromethod) was high (r = 0.82, P < 0.05). Coefficients between TOFHLiD and TOFHLA (heterotrait-monomethod: r = 0.52) and REALM (heterotrait-heteromethod: r = 0.53) were smaller than coefficients for convergent validity Cronbach's alpha for TOFHLiD was 0.63. TOFHLiD was positively correlated with OHIP-14 (P < 0.05), but not with parent or child oral health. TOFHLA was not related to dental outcomes. TOFHLiD demonstrates good convergent validity but only moderate ability to discriminate between dental and medical health literacy. Its predictive validity is only partially established, and internal consistency just meets the threshold for acceptability. Results provide solid support for more research, but not widespread use in clinical or public

  19. Structure of four executive functioning tests in healthy older adults.

    PubMed

    de Frias, Cindy M; Dixon, Roger A; Strauss, Esther

    2006-03-01

    The authors examined the factor structure of 4 indicators of executive functioning derived from 2 new (i.e., Hayling and Brixton) and 2 traditional (i.e., Stroop and Color Trails) tests. Data were from a cross-sectional sample of 55- to 85-year-old healthy adults (N=427) from the Victoria Longitudinal Study. Confirmatory factor analysis (LISREL 8.52) tested both a 2-factor model of Inhibition (Hayling, Stroop) and Shifting (Brixton, Color Trails) and a single-factor model. The 2-factor model did not fit the data because the covariance matrix of the factors was not positive definite. The single-factor model fit the data well, chi(2)(2, N=427)=0.32, p=.85, root-mean-square error of approximation (RMSEA)=.00, comparative fit index (CFI)=1.00, goodness-of-fit index (GFI)=1.00. Moreover, the single-factor structure of executive functioning was invariant (configural and metric) across gender, and invariant (configural with limited metric) across age. Structural relations showed that poorer executive functioning performance was related to older age and lower fluid intelligence, chi(2)(11, N=418)=23.04, p=.02, RMSEA=.05, CFI=.97, GFI=.98.

  20. Bayesian modelling of lung function data from multiple-breath washout tests.

    PubMed

    Mahar, Robert K; Carlin, John B; Ranganathan, Sarath; Ponsonby, Anne-Louise; Vuillermin, Peter; Vukcevic, Damjan

    2018-05-30

    Paediatric respiratory researchers have widely adopted the multiple-breath washout (MBW) test because it allows assessment of lung function in unsedated infants and is well suited to longitudinal studies of lung development and disease. However, a substantial proportion of MBW tests in infants fail current acceptability criteria. We hypothesised that a model-based approach to analysing the data, in place of traditional simple empirical summaries, would enable more efficient use of these tests. We therefore developed a novel statistical model for infant MBW data and applied it to 1197 tests from 432 individuals from a large birth cohort study. We focus on Bayesian estimation of the lung clearance index, the most commonly used summary of lung function from MBW tests. Our results show that the model provides an excellent fit to the data and shed further light on statistical properties of the standard empirical approach. Furthermore, the modelling approach enables the lung clearance index to be estimated by using tests with different degrees of completeness, something not possible with the standard approach. Our model therefore allows previously unused data to be used rather than discarded, as well as routine use of shorter tests without significant loss of precision. Beyond our specific application, our work illustrates a number of important aspects of Bayesian modelling in practice, such as the importance of hierarchical specifications to account for repeated measurements and the value of model checking via posterior predictive distributions. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Variation is function: Are single cell differences functionally important?: Testing the hypothesis that single cell variation is required for aggregate function.

    PubMed

    Dueck, Hannah; Eberwine, James; Kim, Junhyong

    2016-02-01

    There is a growing appreciation of the extent of transcriptome variation across individual cells of the same cell type. While expression variation may be a byproduct of, for example, dynamic or homeostatic processes, here we consider whether single-cell molecular variation per se might be crucial for population-level function. Under this hypothesis, molecular variation indicates a diversity of hidden functional capacities within an ensemble of identical cells, and this functional diversity facilitates collective behavior that would be inaccessible to a homogenous population. In reviewing this topic, we explore possible functions that might be carried by a heterogeneous ensemble of cells; however, this question has proven difficult to test, both because methods to manipulate molecular variation are limited and because it is complicated to define, and measure, population-level function. We consider several possible methods to further pursue the hypothesis that variation is function through the use of comparative analysis and novel experimental techniques. © 2015 The Authors. BioEssays published by WILEY Periodicals, Inc.

  2. Testing a Model of Functional Impairment in Telephone Crisis Support Workers.

    PubMed

    Kitchingman, Taneile A; Wilson, Coralie J; Caputi, Peter; Wilson, Ian; Woodward, Alan

    2017-11-01

    It is well known that helping professionals experience functional impairment related to elevated symptoms of psychological distress as a result of frequent empathic engagement with distressed others. Whether telephone crisis support workers are impacted in a similar way is not currently reported in the literature. The purpose of this study was to test a hypothesized model of factors contributing to functional impairment in telephone crisis support workers. A national sample of 210 telephone crisis support workers completed an online survey including measures of emotion regulation, symptoms of general psychological distress and suicidal ideation, intentions to seek help for symptoms, and functional impairment. Structural equation modeling was used to test the fit of the data to the hypothesized model. Goodness-of-fit indices were adequate and supported the interactive effects of emotion regulation, general psychological distress, suicidal ideation, and intentions to seek help for ideation on functional impairment. These results warrant the deliberate management of telephone crisis support workers' impairment through service selection, training, supervision, and professional development strategies. Future research replicating and extending this model will further inform the modification and/or development of strategies to optimize telephone crisis support workers' well-being and delivery of support to callers.

  3. Differential Item Functioning in While-Listening Performance Tests: The Case of the International English Language Testing System (IELTS) Listening Module

    ERIC Educational Resources Information Center

    Aryadoust, Vahid

    2012-01-01

    This article investigates a version of the International English Language Testing System (IELTS) listening test for evidence of differential item functioning (DIF) based on gender, nationality, age, and degree of previous exposure to the test. Overall, the listening construct was found to be underrepresented, which is probably an important cause…

  4. Functional Task Test: Data Review

    NASA Technical Reports Server (NTRS)

    Cromwell, Ronita

    2014-01-01

    After space flight there are changes in multiple physiological systems including: Cardiovascular function; Sensorimotor function; and Muscle function. How do changes in these physiological system impact astronaut functional performance?

  5. Functional Performance Testing and Patient Reported Outcomes following ACL Reconstruction: A Systematic Scoping Review

    PubMed Central

    Herrington, Lee

    2014-01-01

    Objective. A systematic scoping review of the literature to identify functional performance tests and patient reported outcomes for patients who undergo anterior cruciate ligament (ACL) reconstruction and rehabilitation that are used in clinical practice and research during the last decade. Methods. A literature search was conducted. Electronic databases used included Medline, PubMed, Cochrane Library, EMBASE, CINAHL, SPORTDiscus, PEDro, and AMED. The inclusion criteria were English language, publication between April 2004 and April 2014, and primary ACL reconstruction with objective and/or subjective outcomes used. Two authors screened the selected papers for title, abstract, and full-text in accordance with predefined inclusion and exclusion criteria. The methodological quality of all papers was assessed by a checklist of the Critical Appraisal Skills Programme (CASP). Results. A total of 16 papers were included with full-text. Different authors used different study designs for functional performance testing which led to different outcomes that could not be compared. All papers used a measurement for quantity of functional performance except one study which used both quantity and quality outcomes. Several functional performance tests and patient reported outcomes were identified in this review. Conclusion. No extensive research has been carried out over the past 10 years to measure the quality of functional performance testing and control stability of patients following ACL reconstruction. However this study found that the measurement of functional performance following ACL reconstruction consisting of a one-leg hop for a set distance or a combination of different hops using limb symmetry index (LSI) was a main outcome parameter of several studies. A more extensive series of tests is suggested to measure both the quantitative and qualitative aspects of functional performance after the ACL reconstruction. The KOOS and the IKDC questionnaires are both measures that

  6. Quantitative pilomotor axon reflex test: a novel test of pilomotor function.

    PubMed

    Siepmann, Timo; Gibbons, Christopher H; Illigens, Ben M; Lafo, Jacob A; Brown, Christopher M; Freeman, Roy

    2012-11-01

    Cutaneous autonomic function can be quantified by the assessment of sudomotor and vasomotor responses. Although piloerector muscles are innervated by the sympathetic nervous system, there are at present no methods to quantify pilomotor function. To quantify piloerection using phenylephrine hydrochloride in humans. Pilot study. Hospital-based study. Twenty-two healthy volunteers (18 males,4 females) aged 24 to 48 years participated in 6 studies. Piloerection was stimulated by iontophoresis of 1% phenylephrine. Silicone impressions of piloerection were quantified by number and area. The direct and indirect responses to phenylephrine iontophoresis were compared on both forearms after pre treatment to topical and subcutaneous lidocaine and iontophoresis of normal saline. Iontophoresis of phenylephrine induced piloerection in both the direct and axon reflex–mediated regions, with similar responses in both arms. Topical lidocaine blocked axon reflex–mediated piloerection post-iontophoresis (mean [SD], 66.6 [19.2] for control impressions vs 7.2 [4.3] for lidocaine impressions;P.001). Subcutaneous lidocaine completely blocked piloerection.The area of axon reflex–mediated piloerection was also attenuated in the lidocaine-treated region postiontophoresis (mean [SD], 46.2 [16.1]cm2 vs 7.2 [3.9]cm2; P.001). Piloerection was delayed in the axon reflex region compared with the direct region. Normal saline did not cause piloerection. Phenylephrine provoked piloerection directly and indirectly through an axon reflex–mediated response that is attenuated by lidocaine. Piloerection is not stimulated by iontophoresis of normal saline alone.The quantitative pilomotor axon reflex test (QPART) may complement other measures of cutaneous autonomic nerve fiber function.

  7. Assessment of platelet function in healthy sedated cats using three whole blood platelet function tests.

    PubMed

    Ho, Kimberly K; Abrams-Ogg, Anthony C G; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L

    2015-05-01

    The objectives of this study were to establish feline references intervals for 3 commercial whole blood platelet function test analyzer systems: Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), Platelet Function Analyzer-100 (PF: Siemens Canada, Mississauga, Ontario, Canada), and Plateletworks Combo-25 kit (PW; Helena Laboratories, Beaumont, TX). Venipuncture was performed on 55 healthy sedated cats, and platelet aggregation in response to adenosine diphosphate (ADP), collagen (COL), and arachidonic acid (AA; MP only) was assessed using citrated blood. For the MP analyzer, median (95% confidence intervals [CIs]) area under curve (Units) for ADP, COL, and AA agonists were 87 (11-176), 81 (32-129), and 91 (59-129), respectively. For the PF analyzer, median (95% CIs) closure time, using COL-ADP cartridges, was 69 (46-89) sec. For the PW assay, median (95% CIs) percent aggregations for ADP and COL agonists were 71 (18-92) and 49 (9-96), respectively, using impedance hematology analyzer platelet counts, and 94 (25-98) and 68 (14-119), respectively, using flow cytometry hematology analyzer platelet counts. There were low correlations between the PF analyzer (COL-ADP cartridge) and MP analyzer (COL agonist; ρ = 0.11), and between the PF analyzer (COL-ADP cartridge) and PW assay (COL agonist using impedance platelet counts; ρ = 0.14). The PW assay percent aggregations using impedance and flow cytometric platelet counts were correlated for both ADP (ρ = 0.64) and COL (ρ = 0.64) agonists. Platelet function testing using these tests are feasible in cats, but 95% CIs are wide, so single results may be difficult to interpret. Platelet counting by impedance or flow cytometry may be used for the PW assay but are not interchangeable. © 2015 The Author(s).

  8. Validation of Cardiovascular Parameters during NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, S. H.

    2009-01-01

    Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p<0.006) than inter-session variability (p>0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1

  9. Economic Outcomes With Anatomical Versus Functional Diagnostic Testing for Coronary Artery Disease.

    PubMed

    Mark, Daniel B; Federspiel, Jerome J; Cowper, Patricia A; Anstrom, Kevin J; Hoffmann, Udo; Patel, Manesh R; Davidson-Ray, Linda; Daniels, Melanie R; Cooper, Lawton S; Knight, J David; Lee, Kerry L; Douglas, Pamela S

    2016-07-19

    PROMISE (PROspective Multicenter Imaging Study for Evaluation of Chest Pain) found that initial use of at least 64-slice multidetector computed tomography angiography (CTA) versus functional diagnostic testing strategies did not improve clinical outcomes in stable symptomatic patients with suspected coronary artery disease (CAD) requiring noninvasive testing. To conduct an economic analysis for PROMISE (a major secondary aim of the study). Prospective economic study from the U.S. perspective. Comparisons were made according to the intention-to-treat principle, and CIs were calculated using bootstrap methods. (ClinicalTrials.gov: NCT01174550). 190 U.S. centers. 9649 U.S. patients enrolled in PROMISE between July 2010 and September 2013. Median follow-up was 25 months. Technical costs of the initial (outpatient) testing strategy were estimated from Premier Research Database data. Hospital-based costs were estimated using hospital bills and Medicare cost-charge ratios. Physician fees were taken from the Medicare Physician Fee Schedule. Costs were expressed in 2014 U.S. dollars, discounted at 3% annually, and estimated out to 3 years using inverse probability weighting methods. The mean initial testing costs were $174 for exercise electrocardiography; $404 for CTA; $501 to $514 for pharmacologic and exercise stress echocardiography, respectively; and $946 to $1132 for exercise and pharmacologic stress nuclear testing, respectively. Mean costs at 90 days were $2494 for the CTA strategy versus $2240 for the functional strategy (mean difference, $254 [95% CI, -$634 to $906]). The difference was associated with more revascularizations and catheterizations (4.25 per 100 patients) with CTA use. After 90 days, the mean cost difference between the groups out to 3 years remained small. Cost weights for test strategies were obtained from sources outside PROMISE. Computed tomography angiography and functional diagnostic testing strategies in patients with suspected CAD have

  10. Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.

    PubMed

    Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W

    2017-01-01

    Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2  = 0.839; p < 0.001). The mean increase in thoracic volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Liver function tests abnormality and clinical severity of dengue infection in adult patients.

    PubMed

    Kittitrakul, Chatporn; Silachamroon, Udomsak; Phumratanaprapin, Weerapong; Krudsood, Srivicha; Wilairatana, Polrat; Treeprasertsuk, Sombat

    2015-01-01

    The clinical manifestations of dengue infection in the adult are different from those in children, i.e. having less prevalence to bleeding, and more commonly, abnormal liver function tests. The primary objective is to describe the clinical manifestations of dengue infection in adult patients. The secondary objective is to compare the clinical manifestations of dengue infection between the groups of normal and abnormal liver function tests in adult patients. Retrospective study was done in adults (age 15 years) dengue patients admitted at the Hospital for Tropical Diseases from 2000-2002. Dengue infection diagnosed by WHO clinical criteria 1997 with serological tests confirmed by ELISA test or Rapid Immunochromatographic test. Liver function test was recorded by day of fever. There were 127 adult dengue patients with mean age 26.4 ± 11.5 years. Classifications of dengue infection by WHO criteria were DF 4.7%, DHF grade 126.0%, DHF grade 2 63.0% and DHF grade 3 6.3%. Mean duration of fever clearance time was 6.0 ± 1.9 days but the fever lasted longer in cases of high-level transaminases (> 10 folds). The common presenting symptoms and signs were myalgia (95.9%), nausea/vomiting (87.7%), positive tourniquet test (77.2%), abdominal pain (42.7%), hepatomegaly (34.6%), and bleeding (20.5%). The ratio of AST and ALTwas 1.8:1. Abnormal AST and ALT were found in 88.2% and 69.3% of the patients, respectively. Patients with nausea/vomiting, petechiae or duration of fever > 7 days more frequently had abnormal transaminases. Abnormal AST during the febrile stage was associated with bleeding. High-level AST and ALT occurred in 11.0% and 7.0%, respectively. Shock was associated with high-level ALT during the febrile stage. Adult dengue patients commonly showed abnormal liver function tests and accounted for at least two-thirds of them. High-level ALT during the febrile stage showed association with shock.

  12. Mononuclear leucocyte function tests in the assessment of the biocompatibility of peritoneal dialysis fluids.

    PubMed

    Brulez, H F; ter Wee, P M; Snijders, S V; Donker, A J; Verbrugh, H A

    1999-12-01

    Previous studies showed that the currently used dextrose based peritoneal dialysis fluids impair several leucocyte functions. To determine which in vitro mononuclear leucocyte (monocyte) function tests most clearly reflect the biocompatibility of peritoneal dialysis fluid. Monocytes were tested for phagocytic capacity, bactericidal activity, Fc and C3 receptor expression, and chemiluminescence response, and by analysis of the release of interleukin 8 (IL-8) and tumour necrosis factor alpha (TNF alpha) in the presence of test fluids. Cytokine release was studied in an alternative dynamic in vitro peritoneal dialysis model in which monocytes were exposed to test fluid that was continuously equilibrated with an interstitial fluid-like medium through a microporous membrane. The chemiluminescence response by stressed monocytes was also tested after an 18 h recovery period. All tests were performed during or after exposure to different degrees of glycerol induced osmotic stress and after exposure to a 1% milk-whey derived, polypeptide enriched test fluid. Cells incubated in 0.1% gel Hanks buffer (GH) served as control. Osmotic stress induced impairment of leucocyte function was found by the chemiluminescence assay (mean (SEM): 179 (20)% v 138 (23)% after 30 minutes in 0.5% and 1.5% glycerol, respectively) and by the analysis of IL-8 released by monocytes (44 (9) ng in 0.7% glycerol v 40 (7) ng in 2.0% glycerol). Only the chemiluminescence assay showed a protective effect of polypeptides on leucocyte function (after > or = 60 minutes). If monocytes were allowed to recover in culture medium after exposure to test fluids, the changes in chemiluminescence response appeared to be reversible after a 30 minute exposure, but became more pronounced after 60 and 120 minutes. The phagocytosis and bacterial killing assays were less sensitive. The observations carried out with the phagocytosis assay did not correspond with the Fc or C3 receptor density data. The release of IL-8 by

  13. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    PubMed

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes

  14. The Mid-Term Changes of Pulmonary Function Tests After Phrenic Nerve Transfer.

    PubMed

    Yavari, Masoud; Hassanpour, Seyed Esmail; Khodayari, Mohammad

    2016-03-01

    In the restoration of elbow flexion, the phrenic nerve has proven to be a good donor, but considering the role of the phrenic nerve in respiratory function, we cannot disregard the potential dangers of this method. In the current study, we reviewed the results of pulmonary function tests (PFT) in four patients who underwent phrenic nerve transfer. We reviewed the results of serial spirometry tests, which were performed before and after phrenic nerve transfer surgery. All patients regained Biceps power to M3 strength or above. None of our patients experienced pulmonary problems or respiratory complaints, but a significant reduction of spirometric parameters occurred after surgery. This study highlights the close link between the role of the phrenic nerve and pulmonary function, such that the use of this nerve as a transfer donor leads to spirometric impairments.

  15. Functionally graded bioactive coatings: From fabrication to testing

    NASA Astrophysics Data System (ADS)

    Foppiano, Silvia

    Every year about half a million Americans undergo total joint replacement surgery of some kind. This number is expected to steadily increase in the future. About 20% of these patients will need a revision surgery because of implant failure, with a significant increase in health care cost. Current implant materials for load bearing applications must be strong enough to support the loads involved in daily activities, and bioinert, to limit reactivity in the body that may cause inflammatory and other adverse reactions. Metal alloys are typically used as materials for load bearing implants and rely on mechanical interlocking to achieve fixation which can be improved by using bone cements. To improve implant osteointegration, metal implants have been coated with a bone-like mineral: hydroxyapatite (HA). The plasma spray technique is commonly used to apply the HA coating. Such implants do not require the use of bone cement. Plasma sprayed HA coated implants are FDA approved and currently on the market, but their properties are not reproducible or reliable. Thus, coating delamination can occur. Our research group developed a novel family of bioactive glasses which were enameled onto titanium alloy using a functionally graded approach. We stratified the coating with different glass compositions to fulfill different functions. We coupled a first glass layer, with a good CTE match to the alloy, with a second layer of bioactive glass obtaining a functionally graded bioactive coating (FGC). In this thesis for the first time the cytocompatibility of novel bioactive glasses, and their functionally graded coatings on Ti6Al4V, was studied with an in vitro bone model (MC3T3-E1.4 mouse preosteblast cells). The novel bioactive glasses are cytocompatible and no compositional change is required. The fabrication process is reproducible, introduces a small (average 6 vol%) amount of crystallization, which does not significantly affect bioactivity in SBF as tested. The coatings are

  16. Intrinsic motivation, neurocognition and psychosocial functioning in schizophrenia: testing mediator and moderator effects.

    PubMed

    Nakagami, Eri; Xie, Bin; Hoe, Maanse; Brekke, John S

    2008-10-01

    This study examined the nature of the relationships among neurocognition, intrinsic motivation, and psychosocial functioning for persons with schizophrenia. Hypotheses concerning both mediator and moderator mechanisms were tested. 120 individuals diagnosed with schizophrenia were recruited as they entered outpatient psychosocial rehabilitation programs. Measures of psychosocial functioning and intrinsic motivation were administered at baseline. Measures of neurocognition were administered at baseline by testers blind to scores on other study variables. Data were analyzed using latent construct modeling to test for mediator and moderator effects. There were strong bivariate relationships between neurocognition, intrinsic motivation, and psychosocial functioning. The results demonstrated that intrinsic motivation strongly mediated the relationship between neurocognition and psychosocial functioning. This mediation was evidenced by: (i) the direct path from neurocognition to functional outcome no longer being statistically significant after the introduction of motivation into the model, (ii) the statistical significance of the indirect path from neurocognition through motivation to functional outcome. There was no support for the two moderation hypotheses: the level of neurocognition did not influence the relationship between intrinsic motivation and psychosocial functioning, nor did the level of intrinsic motivation influence the relationship between neurocognition and psychosocial functioning. Neurocognition influences psychosocial functioning through its relationship with intrinsic motivation. Intrinsic motivation is a critical mechanism for explaining the relationship between neurocognition and psychosocial functioning. Implications for the theoretical understanding and psychosocial treatment of intrinsic motivation in schizophrenia are discussed.

  17. Safety and Function Test Report for the Viryd CS8 Wind Turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roadman, J.; Murphy, M.; van Dam, J.

    2013-10-01

    This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. Several turbines were selected for testing at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) as a part of the Small Wind Turbine Independent Testing project. Safety and function testing is one of up to five tests that may be performed on the turbines. Other tests include duration, power performance, acoustic noise, and power quality. Viryd Technologies, Inc.more » of Austin, Texas, was the recipient of the DOE grant and provided the turbine for testing.« less

  18. The six-minute walk test is an excellent predictor of functional ambulation after total knee arthroplasty

    PubMed Central

    2013-01-01

    Background The Six-minute walk (6MW) and Timed-Up-and-Go (TUG) are short walk tests commonly used to evaluate functional recovery after total knee arthroplasty (TKA). However, little is known about walking capacity of TKA recipients over extended periods typical of everyday living and whether these short walk tests actually predict longer, more functional distances. Further, short walk tests only correlate moderately with patient-reported outcomes. The overarching aims of this study were to compare the performance of TKA recipients in an extended walk test to healthy age-matched controls and to determine the utility of this extended walk test as a research tool to evaluate longer term functional mobility in TKA recipients. Methods The mobility of 32 TKA recipients one year post-surgery and 43 healthy age-matched controls were assessed using the TUG, 6MW and 30-minute walk (30MW) tests. The latter test was repeated one week later. Self-reported function was measured using the WOMAC Index and a physical activity questionnaire. Results 30MW distance was significantly shorter amongst TKA recipients (mean 2108 m [95% CI 1837 to 2381 m]; Controls 3086 m [2981 to 3191 m], P < 0.001). Test-retest repeatability was high (ICC = 0.97, TKA; 0.96, Controls). Amongst TKA recipients, the 30MW distance correlated strongly with the shorter tests (6MW, r = 0.97, P < 0.001; TUG, r = −0.82, P < 0.001). Multiple regression modeling found 6MW distance to be the only significant predictor (P < 0.001) of 30MW distance, explaining 96% of the variability. The TUG test models were moderate predictors of WOMAC function (55%) and physical activity (36%) and were stronger predictors than 6MW and 30 MW tests. Conclusions Though TKA recipients are able to walk for 30 minutes one year post-surgery, their performance falls significantly short of age-matched norms. The 30MW test is strongly predicted by 6MW test performance, thus providing strong construct validity for the use of the 6MW test in

  19. Security of the arbitrated quantum signature protocols revisited

    NASA Astrophysics Data System (ADS)

    Kejia, Zhang; Dan, Li; Qi, Su

    2014-01-01

    Recently, much attention has been paid to the study of arbitrated quantum signature (AQS). Among these studies, the cryptanalysis of some AQS protocols and a series of improved ideas have been proposed. Compared with the previous analysis, we present a security criterion, which can judge whether an AQS protocol is able to prevent the receiver (i.e. one participant in the signature protocol) from forging a legal signature. According to our results, it can be seen that most AQS protocols which are based on the Zeng and Keitel (ZK) model are susceptible to a forgery attack. Furthermore, we present an improved idea of the ZK protocol. Finally, some supplement discussions and several interesting topics are provided.

  20. Evaluation of the Olfactory Function With the "Sniffin' Sticks" Test After Endoscopic Transsphenoidal Pituitary Surgery.

    PubMed

    Cingoz, Ilker Deniz; Kizmazoglu, Ceren; Guvenc, Gonul; Sayin, Murat; Imre, Abdulkadir; Yuceer, Nurullah

    2018-06-01

    The aim of this study was to evaluate the olfactory function of patients who had undergone endoscopic transsphenoidal pituitary surgery. In this prospective study, the "Sniffin' Sticks" test was performed between June 2016 and April 2017 at Izmir Katip Celebi University Ataturk Training and Research Hospital. Thirty patients who were scheduled to undergo endoscopic transsphenoidal pituitary surgery were evaluated preoperatively and 8 weeks postoperatively using the Sniffin' Sticks test battery for olfactory function, odor threshold, smell discrimination, and odor identification. The patients were evaluated preoperatively by an otolaryngologist. The patients' demographic data and olfactory functions were analyzed with a t test and Wilcoxon-labeled sequential test. The study group comprised 14 women (46.7%) and 16 men (53.3%) patients. The mean age of the patients was 37.50 ± 9.43 years (range: 16-53 years). We found a significant difference in the preoperative and postoperative values of the odor recognition test (P = 0.017); however, there was no significant difference between the preoperative and postoperative odor threshold values (P = 0.172) and odor discrimination values (P = 0.624). The threshold discrimination identification test scores were not significant (P = 0.110). The olfactory function of patients who were normosmic preoperatively was not affected postoperatively. This study shows that the endoscopic transsphenoidal technique for pituitary surgery without nasal flap has no negative effect on the olfactory function.

  1. Effect of Exercise on Pulmonary Function Tests in Obese Malaysian Patients.

    PubMed

    Christopher, L K S; Kosai, N R; Reynu, R; Levin, K B; Taher, M M; Sutton, P A; Sukor, N; Das, S

    2015-01-01

    Obesity has taken the 21st century by storm, posing negative effects on of the various facades of health, healthcare and global economy. With regards to pulmonary performance, numerous studies have proven the detrimental effects of obesity while reinstating the positive effects of weight loss on overall pulmonary function. However, effects of exercise on pulmonary function and correlation between changes in pulmonary function test with weight loss have yet to be described. We performed a prospective interventional study to determine the effects of regular exercise on Pulmonary Function Tests (PFT) and ascertain the relationship between weight loss and change in PFT in obese patients. Twenty-five obese patients were enrolled, giving an 80% power of study. Baseline weight and PFT consisting of FEV1, FVC, TLC, mean ERV and VC were recorded prior to commencement of the 8 week long Standard Exercise Regimen (SER). PFT and weight were recorded again at the end of 8 weeks. All parameters of the PFT studied improved significantly with exercise. The participants lost an average of 1kg of body weight post-exercise (p<0.0005). The correlations between mean changes in weight and PFT were negligible. A period of supervised regular exercise improves the pulmonary function of obese patients and this improvement is independent of the amount of weight loss. Hence, SER should be recommended to all obese patients, especially when bariatric surgery is desired.

  2. Pulmonary function tests

    MedlinePlus

    ... exhale, and how quickly you exhale, spirometry can evaluate a broad range of lung diseases. In a ... expiratory volume in 1 second (FEV1) Forced expiratory flow 25% to 75% (FEF25-75) Functional residual capacity ( ...

  3. Effect of exercise test on pulmonary function of obese adolescents.

    PubMed

    Faria, Alethéa Guimarães; Ribeiro, Maria Angela G O; Marson, Fernando Augusto Lima; Schivinski, Camila Isabel S; Severino, Silvana Dalge; Ribeiro, José Dirceu; Barros Filho, Antônio A

    2014-01-01

    to investigate the pulmonary response to exercise of non-morbidly obese adolescents, considering the gender. a prospective cross-sectional study was conducted with 92 adolescents (47 obese and 45 eutrophic), divided in four groups according to obesity and gender. Anthropometric parameters, pulmonary function (spirometry and oxygen saturation [SatO2]), heart rate (HR), blood pressure (BP), respiratory rate (RR), and respiratory muscle strength were measured. Pulmonary function parameters were measured before, during, and after the exercise test. BP and HR were higher in obese individuals during the exercise test (p = 0.0001). SatO2 values decreased during exercise in obese adolescents (p = 0.0001). Obese males had higher levels of maximum inspiratory and expiratory pressures (p = 0.0002) when compared to obese and eutrophic females. Obese males showed lower values of maximum voluntary ventilation, forced vital capacity, and forced expiratory volume in the first second when compared to eutrophic males, before and after exercise (p = 0.0005). Obese females had greater inspiratory capacity compared to eutrophic females (p = 0.0001). Expiratory reserve volume was lower in obese subjects when compared to controls (p ≤ 0,05). obese adolescents presented changes in pulmonary function at rest and these changes remained present during exercise. The spirometric and cardiorespiratory values were different in the four study groups. The present data demonstrated that, in spite of differences in lung growth, the model of fat distribution alters pulmonary function differently in obese female and male adolescents. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  4. Cardio-Pulmonary Function Testing. Continuing Education Curriculum for Respiratory Therapy.

    ERIC Educational Resources Information Center

    Saint Paul Technical Vocational Inst., MN.

    Compiled from interviews with personnel in pulmonary function testing (PFT) laboratories in the Minneapolis/St. Paul area, this competency-based curriculum guide is intended to provide a knowledge of PFT for persons who provide respiratory care. The guide contains 20 sections covering the following topics: vital capacity, flow measurements,…

  5. Nominal and functional task difficulty in skill acquisition: Effects on performance in two tests of transfer.

    PubMed

    Sanli, Elizabeth A; Lee, Timothy D

    2015-06-01

    The influence of nominal and functional task difficulty during the acquisition of a motor skill was examined in two tests of transfer of learning. The task involved a ballistic, target-directed, finger action. Nominal task difficulty was defined as the distance of the target from the home position. Functional task difficulty was created by manipulating the progression of target distances during practice. Based on the challenge point framework (Guadagnoli & Lee, 2004), we predicted that practice with a set of targets farther away from the performer would benefit from less functional task difficulty, while practice with a closer set of targets would benefit from more functional task difficulty. In single-task transfer tests, learners who practiced using the high nominal task difficulty targets benefitted in terms of persistence of performance over time. In dual-task transfer tests, groups with an intermediate combined (nominal and functional) task difficulty performed with greater persistence over time on tests of transfer than those who practiced with the highest or lowest combined difficulty. Together these findings suggest that the influences of nominal and functional task difficulty during acquisition are weighted differentially depending upon the transfer test context. The challenge point framework does not accurately capture this complex relationship in its current form. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Functional MR imaging or Wada test: which is the better predictor of individual postoperative memory outcome?

    PubMed

    Dupont, Sophie; Duron, Emmanuelle; Samson, Séverine; Denos, Marisa; Volle, Emmanuelle; Delmaire, Christine; Navarro, Vincent; Chiras, Jacques; Lehéricy, Stéphane; Samson, Yves; Baulac, Michel

    2010-04-01

    To retrospectively determine whether blood oxygen level-dependent functional magnetic resonance (MR) imaging can aid prediction of postoperative memory changes in epileptic patients after temporal lobe surgery. This study was approved by the local ethics committee, and informed consent was obtained from all patients. Data were analyzed from 25 patients (12 women, 13 men; age range, 19-52 years) with refractory epilepsy in whom temporal lobe surgery was performed after they underwent preoperative functional MR imaging, the Wada test, and neuropsychological testing. The functional MR imaging protocol included three different memory tasks (24-hour delayed recognition, encoding, and immediate recognition). Individual activations were measured in medial temporal lobe (MTL) regions of both hemispheres. The prognostic accuracy of functional MR imaging for prediction of postoperative memory changes was compared with the accuracy of the Wada test and preoperative neuropsychological testing by using a backward multiple regression analysis. An equation that was based on left functional MR imaging MTL activation during delayed recognition, side of the epileptic focus, and preoperative global verbal memory score was used to correctly predict worsening of verbal memory in 90% of patients. The right functional MR imaging MTL activation did not substantially correlate with the nonverbal memory outcome, which was only predicted by using the preoperative nonverbal global score. Wada test data were not good predictors of changes in either verbal or nonverbal memory. Findings suggest that functional MR imaging activation during a delayed-recognition task is a better predictor of individual postoperative verbal memory outcome than is the Wada test. RSNA, 2010

  7. Comparison of Combined Endoscopic Ultrasonography and Endoscopic Secretin Testing With the Traditional Secretin Pancreatic Function Test in Patients With Suspected Chronic Pancreatitis: A Prospective Crossover Study.

    PubMed

    Kothari, Darshan; Ketwaroo, Gyanprakash; Sawhney, Mandeep S; Freedman, Steven D; Sheth, Sunil G

    2017-07-01

    We aimed to determine the feasibility and accuracy of a combined endoscopic ultrasonography (EUS) with a shortened pancreatic function testing (sEUS) for structural and functional assessment using a single instrument in patients with suspected chronic pancreatitis (CP). We completed a prospective crossover study, enrolling patients with suspected CP. Patients who underwent both traditional 1-hour secretin pancreatic function test (sPFT) and sEUS were included in the analysis. We compared study results for test concordance and for correlation of peak bicarbonate concentrations. Eleven (64.7%) of 17 patients had concordant sPFT and sEUS findings when the cutoff for peak bicarbonate was 80 mEq/L. Six patients had discordant findings with a negative sPFT and positive sEUS. This poor concordance suggests that sEUS is an unreliable functional test. Lowering the sEUS cutoff to 70 mEq/L resulted in improved concordance (64.7% vs 70.6%). Finally, there was no significant correlation between peak bicarbonate concentrations (r = 0.47; 95% confidence interval, -0.02 to 0.79) in these 2 functional tests. We demonstrate poor concordance between sPFT and sEUS suggesting that a combined shortened functional and structural test using a single instrument may not be a feasible test for diagnosis of suspected CP when a cutoff of 80 mEq/L is used.

  8. Economic Outcomes with Anatomic versus Functional Diagnostic Testing for Coronary Artery Disease

    PubMed Central

    Mark, Daniel B.; Federspiel, Jerome J.; Cowper, Patricia A.; Anstrom, Kevin J.; Hoffmann, Udo; Patel, Manesh R.; Davidson-Ray, Linda; Daniels, Melanie R.; Cooper, Lawton S.; Knight, J. David; Lee, Kerry L.; Douglas, Pamela S.

    2016-01-01

    Background The PROMISE trial found that initial use of ≥64-slice multidetector computed tomographic angiography (CTA) versus functional diagnostic testing strategies did not improve clinical outcomes in stable symptomatic patients with suspected coronary artery disease (CAD) requiring noninvasive testing. Objective Economic analysis of PROMISE, a major secondary aim. Design Prospective economic study from the US perspective. Comparisons were made by intention-to-treat. Confidence intervals were calculated using bootstrap methods. Setting 190 U.S. centers Patients 9649 U.S. patients enrolled in PROMISE. Enrollment began July 2010 and completed September 2013. Median follow-up was 25 months. Measurements Technical costs of the initial (outpatient) testing strategy were estimated from Premier Research Database data. Hospital-based costs were estimated using hospital bills and Medicare cost-to-charge ratios. Physician fees were taken from the Medicare Fee Schedule. Costs were expressed in 2014 US dollars discounted at 3% and estimated out to 3 years using inverse probability weighting methods. Results The mean initial testing costs were: $174 for exercise ECG; $404 for CTA; $501 to $514 for (exercise, pharmacologic) stress echo; $946 to $1132 for (exercise, pharmacologic) stress nuclear. Mean costs at 90 days for the CTA strategy were $2494 versus $2240 for the functional strategy (mean difference $254, 95% CI −$634 to $906). The difference was associated with more revascularizations and catheterizations (4.25 per 100 patients) with CTA use. After 90 days, the mean cost difference between the arms out to 3 years remained small ($373). Limitations Cost weights for test strategies obtained from sources outside PROMISE. Conclusions CTA and functional diagnostic testing strategies in patients with suspected CAD have similar costs through three years of follow-up. PMID:27214597

  9. Causes of altered liver function tests - the role of alpha-1 antitrypsin.

    PubMed

    Stollenwerk, J; Schepke, M; Biecker, E

    2016-09-01

    Altered liver function tests are a common finding in clinical practice. Our retrospective study aimed to identify the diagnoses in a non-selected cohort of patients with altered liver tests and to investigate whether alpha-1 antitrypsin genotyping should be part of the diagnostic workup. 501 patients who were admitted to our outpatient clinic for further evaluation of altered liver function tests were included in the study. The patients underwent a standardized diagnostic program with history taking, physical examination, laboratory tests and ultrasonography. Liver biopsy was performed if appropriate. More than 50 % of the patients had nonalcoholic fatty liver disease. Alcoholic and drug-induced liver injury were found in 8.6 % and 7 % of patients, respectively. Chronic hepatitis B and C, autoimmune liver disease and inherited causes of liver disease made up for approximately 16 % of the diagnoses. The remaining patients were diagnosed with kryptogenic liver disease or had miscellaneous diagnoses. In 3.7 % of the genotyped patients, the alpha-1 antitrypsin genotype PiMZ was found. Nonalcoholic fatty liver disease is nowadays the most frequent cause of altered liver tests. Alcoholic liver disease might be underrepresented in our study since these patients less often seek medical attention or the diagnosis is already made by the primary care physician. Drug-induced liver injury was found in more patients than expected and might therefore be underdiagnosed in practice. The alpha-1 antitrypsin genotype PiMZ was found in absence of other possible causes of liver disease, indicating that the PiMZ genotype is itself a risk factor for liver disease. Genotyping for alpha-1 antitrypsin should therefore be done when other causes for altered liver function tests have been ruled out. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Inter-rater reliability of three standardized functional tests in patients with low back pain

    PubMed Central

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  11. Spaceflight-Induced Cardiovascular Changes and Recovery During NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, S. H.

    2010-01-01

    Microgravity-induced physiological changes could impair a crewmember s performance upon return to a gravity environment. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in mission-critical tasks. The Recovery from Fall/Stand Test (RFST) simulates one such task, measuring the ability to recover from a prone position and the cardiovascular response to orthostasis. The purpose of this study was to evaluate spaceflight-induced cardiovascular changes during the FTT. METHODS: Five astronauts participated in the FTT before 10-15 day missions, on landing day (R+0), and one (R+1), six (R+6) and thirty (R+30) days after landing. The RFST consisted of a 2-minute prone rest followed by a 3-minute stand during which heart rate (HR, Holter) and continuous blood pressure (BP, Finometer) were measured. Spectral heart rate variability (HRV) was calculated during the RFST to approximate autonomic function. Statistical analysis was performed with two-factor repeated measures ANOVA. RESULTS: During RFST, HR was higher on R+0 than preflight (p<0.004). This increase in HR persisted on R+1 and R+6 during the stand portion of RFST (p<0.026). BP was well-regulated on all test days. Parasympathetic activity was diminished on R+0 (p=0.035). Sympathovagal balance tended to be affected by spaceflight (main effect, p=0.072), appearing to be slightly elevated during postflight RFST except on R+30. Additionally, analysis of HR during the functional tasks yielded a higher HR on R+0 than preflight during 8 of 11 tasks analyzed, where all tasks had HR return to preflight values by R+30 (p<0.05). CONCLUSION: Spaceflight causes an increase in HR, decrease in parasympathetic activity, and increase in sympathovagal balance, which we confirmed during RFST. These spaceflight-induced changes seen in the RFST, along with the increased postflight HR in most functional tasks, can be used to assess functional performance after short-duration spaceflight.

  12. Prediction of postoperative outcome after hepatectomy with a new bedside test for maximal liver function capacity.

    PubMed

    Stockmann, Martin; Lock, Johan F; Riecke, Björn; Heyne, Karsten; Martus, Peter; Fricke, Michael; Lehmann, Sina; Niehues, Stefan M; Schwabe, Michael; Lemke, Arne-Jörn; Neuhaus, Peter

    2009-07-01

    To validate the LiMAx test, a new bedside test for the determination of maximal liver function capacity based on C-methacetin kinetics. To investigate the diagnostic performance of different liver function tests and scores including the LiMAx test for the prediction of postoperative outcome after hepatectomy. Liver failure is a major cause of mortality after hepatectomy. Preoperative prediction of residual liver function has been limited so far. Sixty-four patients undergoing hepatectomy were analyzed in a prospective observational study. Volumetric analysis of the liver was carried out using preoperative computed tomography and intraoperative measurements. Perioperative factors associated with morbidity and mortality were analyzed. Cutoff values of the LiMAx test were evaluated by receiver operating characteristic. Residual LiMAx demonstrated an excellent linear correlation with residual liver volume (r = 0.94, P < 0.001) after hepatectomy. The multivariate analysis revealed LiMAx on postoperative day 1 as the only predictor of liver failure (P = 0.003) and mortality (P = 0.004). AUROC for the prediction of liver failure and liver failure related death by the LiMAx test was both 0.99. Preoperative volume/function analysis combining CT volumetry and LiMAx allowed an accurate calculation of the remnant liver function capacity prior to surgery (r = 0.85, P < 0.001). Residual liver function is the major factor influencing the outcome of patients after hepatectomy and can be predicted preoperatively by a combination of LiMAx and CT volumetry.

  13. Testing for Differential Item Functioning with Measures of Partial Association

    ERIC Educational Resources Information Center

    Woods, Carol M.

    2009-01-01

    Differential item functioning (DIF) occurs when an item on a test or questionnaire has different measurement properties for one group of people versus another, irrespective of mean differences on the construct. There are many methods available for DIF assessment. The present article is focused on indices of partial association. A family of average…

  14. Development and validation of a new instrument for testing functional health literacy in Japanese adults.

    PubMed

    Nakagami, Katsuyuki; Yamauchi, Toyoaki; Noguchi, Hiroyuki; Maeda, Tohru; Nakagami, Tomoko

    2014-06-01

    This study aimed to develop a reliable and valid measure of functional health literacy in a Japanese clinical setting. Test development consisted of three phases: generation of an item pool, consultation with experts to assess content validity, and comparison with external criteria (the Japanese Health Knowledge Test) to assess criterion validity. A trial version of the test was administered to 535 Japanese outpatients. Internal consistency reliability, calculated by Cronbach's alpha, was 0.81, and concurrent validity was moderate. Receiver Operating Characteristics and Item Response Theory were used to classify patients as having adequate, marginal, or inadequate functional health literacy. Both inadequate and marginal functional health literacy were associated with older age, lower income, lower educational attainment, and poor health knowledge. The time required to complete the test was 10-15 min. This test should enable health workers to better identify patients with inadequate health literacy. © 2013 Wiley Publishing Asia Pty Ltd.

  15. It Might Not Make a Big DIF: Improved Differential Test Functioning Statistics That Account for Sampling Variability

    ERIC Educational Resources Information Center

    Chalmers, R. Philip; Counsell, Alyssa; Flora, David B.

    2016-01-01

    Differential test functioning, or DTF, occurs when one or more items in a test demonstrate differential item functioning (DIF) and the aggregate of these effects are witnessed at the test level. In many applications, DTF can be more important than DIF when the overall effects of DIF at the test level can be quantified. However, optimal statistical…

  16. Clinical measurement of gastrointestinal motility and function: who, when and which test?

    PubMed

    Fox, Mark R; Kahrilas, Peter J; Roman, Sabine; Gyawali, C Prakash; Scott, S Mark; Rao, Satish S; Keller, Jutta; Camilleri, Michael

    2018-06-05

    Symptoms related to abnormal gastrointestinal motility and function are common. Oropharyngeal and oesophageal dysphagia, heartburn, bloating, abdominal pain and alterations in bowel habits are among the most frequent reasons for seeking medical attention from internists or general practitioners and are also common reasons for referral to gastroenterologists and colorectal surgeons. However, the nonspecific nature of gastrointestinal symptoms, the absence of a definitive diagnosis on routine investigations (such as endoscopy, radiology or blood tests) and the lack of specific treatments make disease management challenging. Advances in technology have driven progress in the understanding of many of these conditions. This Review serves as an introduction to a series of Consensus Statements on the clinical measurements of gastrointestinal motility, function and sensitivity. A structured, evidence-based approach to the initial assessment and empirical treatment of patients presenting with gastrointestinal symptoms is discussed, followed by an outline of the contribution of modern physiological measurement on the management of patients in whom the cause of symptoms has not been identified with other tests. Discussions include the indications for and utility of high-resolution manometry, ambulatory pH-impedance monitoring, gastric emptying studies, breath tests and investigations of anorectal structure and function in day-to-day practice and clinical management.

  17. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis.

    PubMed

    Tilanus, T B M; Groothuis, J T; TenBroek-Pastoor, J M C; Feuth, T B; Heijdra, Y F; Slenders, J P L; Doorduin, J; Van Engelen, B G; Kampelmacher, M J; Raaphorst, J

    2017-07-25

    Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity (FVC), peak cough flow (PCF), maximum inspiratory and expiratory pressure (MIP and MEP) and sniff nasal inspiratory pressure (SNIP) in patients with ALS. Patients who had had at least one assessment of respiratory function and one visit at the HVS, were included. Our aim was to detect the test with the highest predictive value for the need for elective NIV in the following 3 months. We analysed time curves, currently used cut-off values for referral, and respiratory function test results between 'NIV indication' and 'no-NIV indication' patients. One hundred ten patients with ALS were included of whom 87 received an NIV indication; 11.5% had one assessment before receiving an NIV indication, 88.5% had two or more assessments. The NIV indication was based on complaints of hypoventilation and/or proven (nocturnal) hypercapnia. The five respiratory function tests showed a descending trend during disease progression, where SNIP showed the greatest decline within the latest 3 months before NIV indication (mean = -22%). PCF at the time of referral to the HVS significantly discriminated between the groups 'NIV-indication' and 'no NIV-indication yet' patients at the first HVS visit: 259 (±92) vs. 348 (±137) L/min, p = 0.019. PCF and SNIP showed the best predictive characteristics in terms of sensitivity. SNIP showed the greatest decline prior to NIV indication and PCF significantly differentiated 'NIV-indication' from 'no NIV-indication yet' patients with ALS. Currently used cut-off values might be

  18. Timed function tests, motor function measure, and quantitative thigh muscle MRI in ambulant children with Duchenne muscular dystrophy: A cross-sectional analysis.

    PubMed

    Schmidt, Simone; Hafner, Patricia; Klein, Andrea; Rubino-Nacht, Daniela; Gocheva, Vanya; Schroeder, Jonas; Naduvilekoot Devasia, Arjith; Zuesli, Stephanie; Bernert, Guenther; Laugel, Vincent; Bloetzer, Clemens; Steinlin, Maja; Capone, Andrea; Gloor, Monika; Tobler, Patrick; Haas, Tanja; Bieri, Oliver; Zumbrunn, Thomas; Fischer, Dirk; Bonati, Ulrike

    2018-01-01

    The development of new therapeutic agents for the treatment of Duchenne muscular dystrophy has put a focus on defining outcome measures most sensitive to capture treatment effects. This cross-sectional analysis investigates the relation between validated clinical assessments such as the 6-minute walk test, motor function measure and quantitative muscle MRI of thigh muscles in ambulant Duchenne muscular dystrophy patients, aged 6.5 to 10.8 years (mean 8.2, SD 1.1). Quantitative muscle MRI included the mean fat fraction using a 2-point Dixon technique, and transverse relaxation time (T2) measurements. All clinical assessments were highly significantly inter-correlated with p < 0.001. The strongest correlation with the motor function measure and its D1-subscore was shown by the 6-minute walk test. Clinical assessments showed no correlation with age. Importantly, quantitative muscle MRI values significantly correlated with all clinical assessments with the extensors showing the strongest correlation. In contrast to the clinical assessments, quantitative muscle MRI values were highly significantly correlated with age. In conclusion, the motor function measure and timed function tests measure disease severity in a highly comparable fashion and all tests correlated with quantitative muscle MRI values quantifying fatty muscle degeneration. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Highly adaptive tests for group differences in brain functional connectivity.

    PubMed

    Kim, Junghi; Pan, Wei

    2015-01-01

    Resting-state functional magnetic resonance imaging (rs-fMRI) and other technologies have been offering evidence and insights showing that altered brain functional networks are associated with neurological illnesses such as Alzheimer's disease. Exploring brain networks of clinical populations compared to those of controls would be a key inquiry to reveal underlying neurological processes related to such illnesses. For such a purpose, group-level inference is a necessary first step in order to establish whether there are any genuinely disrupted brain subnetworks. Such an analysis is also challenging due to the high dimensionality of the parameters in a network model and high noise levels in neuroimaging data. We are still in the early stage of method development as highlighted by Varoquaux and Craddock (2013) that "there is currently no unique solution, but a spectrum of related methods and analytical strategies" to learn and compare brain connectivity. In practice the important issue of how to choose several critical parameters in estimating a network, such as what association measure to use and what is the sparsity of the estimated network, has not been carefully addressed, largely because the answers are unknown yet. For example, even though the choice of tuning parameters in model estimation has been extensively discussed in the literature, as to be shown here, an optimal choice of a parameter for network estimation may not be optimal in the current context of hypothesis testing. Arbitrarily choosing or mis-specifying such parameters may lead to extremely low-powered tests. Here we develop highly adaptive tests to detect group differences in brain connectivity while accounting for unknown optimal choices of some tuning parameters. The proposed tests combine statistical evidence against a null hypothesis from multiple sources across a range of plausible tuning parameter values reflecting uncertainty with the unknown truth. These highly adaptive tests are not only

  20. An objective measure of physical function of elderly outpatients. The Physical Performance Test.

    PubMed

    Reuben, D B; Siu, A L

    1990-10-01

    Direct observation of physical function has the advantage of providing an objective, quantifiable measure of functional capabilities. We have developed the Physical Performance Test (PPT), which assesses multiple domains of physical function using observed performance of tasks that simulate activities of daily living of various degrees of difficulty. Two versions are presented: a nine-item scale that includes writing a sentence, simulated eating, turning 360 degrees, putting on and removing a jacket, lifting a book and putting it on a shelf, picking up a penny from the floor, a 50-foot walk test, and climbing stairs (scored as two items); and a seven-item scale that does not include stairs. The PPT can be completed in less than 10 minutes and requires only a few simple props. We then tested the validity of PPT using 183 subjects (mean age, 79 years) in six settings including four clinical practices (one of Parkinson's disease patients), a board-and-care home, and a senior citizens' apartment. The PPT was reliable (Cronbach's alpha = 0.87 and 0.79, interrater reliability = 0.99 and 0.93 for the nine-item and seven-item tests, respectively) and demonstrated concurrent validity with self-reported measures of physical function. Scores on the PPT for both scales were highly correlated (.50 to .80) with modified Rosow-Breslau, Instrumental and Basic Activities of Daily Living scales, and Tinetti gait score. Scores on the PPT were more moderately correlated with self-reported health status, cognitive status, and mental health (.24 to .47), and negatively with age (-.24 and -.18). Thus, the PPT also demonstrated construct validity. The PPT is a promising objective measurement of physical function, but its clinical and research value for screening, monitoring, and prediction will have to be determined.

  1. Clinical history and biologic age predicted falls better than objective functional tests.

    PubMed

    Gerdhem, Paul; Ringsberg, Karin A M; Akesson, Kristina; Obrant, Karl J

    2005-03-01

    Fall risk assessment is important because the consequences, such as a fracture, may be devastating. The objective of this study was to find the test or tests that best predicted falls in a population-based sample of elderly women. The fall-predictive ability of a questionnaire, a subjective estimate of biologic age and objective functional tests (gait, balance [Romberg and sway test], thigh muscle strength, and visual acuity) were compared in 984 randomly selected women, all 75 years of age. A recalled fall was the most important predictor for future falls. Only recalled falls and intake of psycho-active drugs independently predicted future falls. Women with at least five of the most important fall predictors (previous falls, conditions affecting the balance, tendency to fall, intake of psychoactive medication, inability to stand on one leg, high biologic age) had an odds ratio of 11.27 (95% confidence interval 4.61-27.60) for a fall (sensitivity 70%, specificity 79%). The more time-consuming objective functional tests were of limited importance for fall prediction. A simple clinical history, the inability to stand on one leg, and a subjective estimate of biologic age were more important as part of the fall risk assessment.

  2. Lower extremity functional tests and risk of injury in division iii collegiate athletes.

    PubMed

    Brumitt, Jason; Heiderscheit, Bryan C; Manske, Robert C; Niemuth, Paul E; Rauh, Mitchell J

    2013-06-01

    Functional tests have been used primarily to assess an athlete's fitness or readiness to return to sport. The purpose of this prospective cohort study was to determine the ability of the standing long jump (SLJ) test, the single-leg hop (SLH) for distance test, and the lower extremity functional test (LEFT) as preseason screening tools to identify collegiate athletes who may be at increased risk for a time-loss sports-related low back or lower extremity injury. A total of 193 Division III athletes from 15 university teams (110 females, age 19.1 ± 1.1 y; 83 males, age 19.5 ± 1.3 y) were tested prior to their sports seasons. Athletes performed the functional tests in the following sequence: SLJ, SLH, LEFT. The athletes were then prospectively followed during their sports season for occurrence of low back or LE injury. Female athletes who completed the LEFT in $118 s were 6 times more likely (OR=6.4, 95% CI: 1.3, 31.7) to sustain a thigh or knee injury. Male athletes who completed the LEFT in #100 s were more likely to experience a time-loss injury to the low back or LE (OR=3.2, 95% CI: 1.1, 9.5) or a foot or ankle injury (OR=6.7, 95% CI: 1.5, 29.7) than male athletes who completed the LEFT in 101 s or more. Female athletes with a greater than 10% side-to-side asymmetry between SLH distances had a 4-fold increase in foot or ankle injury (cut point: >10%; OR=4.4, 95% CI: 1.2, 15.4). Male athletes with SLH distances (either leg) at least 75% of their height had at least a 3-fold increase (OR=3.6, 95% CI: 1.2, 11.2 for the right LE; OR=3.6, 95% CI: 1.2, 11.2 for left LE) in low back or LE injury. The LEFT and the SLH tests appear useful in identifying Division III athletes at risk for a low back or lower extremity sports injury. Thus, these tests warrant further consideration as preparticipatory screening examination tools for sport injury in this population. The single-leg hop for distance and the lower extremity functional test, when administered to Division III

  3. Validation of a Computerized test of Functional Capacity.

    PubMed

    Keefe, Richard S E; Davis, Vicki G; Atkins, Alexandra S; Vaughan, Adam; Patterson, Tom; Narasimhan, Meera; Harvey, Philip D

    2016-08-01

    Regulatory guidance for schizophrenia cognition clinical trials requires that the assessment of cognitive change is accompanied by a functionally meaningful endpoint. However, currently available measures are challenged by resistance to change, psychometric weaknesses, and for interview-based assessments, dependence upon the presence of an informant. The aims of the current study were to: 1) assess the validity, sensitivity, and reliability of the Virtual Reality Functional Capacity Assessment Tool (VRFCAT) as a measure of functional capacity; 2) determine the association between performance on the VRFCAT and performance on the MATRICS Consensus Cognitive Battery (MCCB); and 3) compare the metrics of the VRFCAT with the UCSD Performance-based Skills Assessment (UPSA). 167 patients with schizophrenia and 166 healthy controls completed the VRFCAT, UPSA, and the MCCB at baseline. The VRFCAT and UPSA were completed again at follow-up. The VRFCAT, MCCB, and UPSA were very sensitive to impairment in schizophrenia (d=1.16 to 1.22). High test-retest reliability was demonstrated for VRFCAT total completion time and the UPSA total score in patients (ICC=0.81 and 0.78, respectively). The UPSA demonstrated significant practice effects in patients (d=0.35), while the VRFCAT did not (d=-0.04). VRFCAT total completion time was correlated with both UPSA (r=-0.56, p<0.0001 for patients and -0.58, p<0.0001 for controls) and MCCB Composite (r=-0.57, p<0.0001 for patients and -0.68, p<0.0001 for controls). The VRFCAT is a highly reliable and sensitive measure of functional capacity with associations to the UPSA and MCCB. These results provide encouraging support for a computerized functional capacity assessment for use in schizophrenia. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Validation of a Computerized Test of Functional Capacity

    PubMed Central

    Keefe, Richard S.E.; Davis, Vicki G.; Atkins, Alexandra S.; Vaughan, Adam; Patterson, Tom; Narasimhan, Meera; Harvey, Philip D.

    2016-01-01

    Regulatory guidance for schizophrenia cognition clinical trials requires that the assessment of cognitive change is accompanied by a functionally meaningful endpoint. However, currently available measures are challenged by resistance to change, psychometric weaknesses, and for interview-based assessments, dependence upon the presence of an informant. The aims of the current study were to: 1) assess the validity, sensitivity, and reliability of the Virtual Reality Functional Capacity Assessment Tool (VRFCAT) as a measure of functional capacity; 2) determine the association between performance on the VRFCAT and performance on the MATRICS Consensus Cognitive Battery (MCCB); and 3) compare the metrics of the VRFCAT with the UCSD Performance-based Skills Assessment (UPSA). 167 patients with schizophrenia and 166 healthy controls completed the VRFCAT, UPSA, and the MCCB at baseline. The VRFCAT and UPSA were completed again at follow-up. The VRFCAT, MCCB, and UPSA were very sensitive to impairment in schizophrenia (d = 1.16 to 1.22). High test-retest reliability was demonstrated for VRFCAT total completion time and the UPSA total score in patients (ICC=0.81 and 0.78, respectively). The UPSA demonstrated significant practice effects in patients (d=0.35), while the VRFCAT did not (d=−0.04). VRFCAT total completion time was correlated with both UPSA (r=−0.56, p<0.0001 for patients and −0.58, p<0.0001 for controls) and MCCB Composite (r=−0.57, p<0.0001 for patients and −0.68, p<0.0001 for controls). The VRFCAT is a highly reliable and sensitive measure of functional capacity with associations to the UPSA and MCCB. These results provide encouraging support for a computerized functional capacity assessment for use in schizophrenia. PMID:27091656

  5. Functional test generation for digital circuits described with a declarative language: LUSTRE

    NASA Astrophysics Data System (ADS)

    Almahrous, Mazen

    1990-08-01

    A functional approach to the test generation problem starting from a high level description is proposed. The circuit tested is modeled, using the LUSTRE high level data flow description language. The different LUSTRE primitives are translated to a SATAN format graph in order to evaluate the testability of the circuit and to generate test sequences. Another method of testing the complex circuits comprising an operative part and a control part is defined. It consists of checking experiments for the control part observed through the operative part. It was applied to the automata generated from a LUSTRE description of the circuit.

  6. Ground Test of the Urine Processing Assembly for Accelerations and Transfer Functions

    NASA Technical Reports Server (NTRS)

    Houston, Janice; Almond, Deborah F. (Technical Monitor)

    2001-01-01

    This viewgraph presentation gives an overview of the ground test of the urine processing assembly for accelerations and transfer functions. Details are given on the test setup, test data, data analysis, analytical results, and microgravity assessment. The conclusions of the tests include the following: (1) the single input/multiple output method is useful if the data is acquired by tri-axial accelerometers and inputs can be considered uncorrelated; (2) tying coherence with the matrix yields higher confidence in results; (3) the WRS#2 rack ORUs need to be isolated; (4) and future work includes a plan for characterizing performance of isolation materials.

  7. 13C Methacetin Breath Test for Assessment of Microsomal Liver Function: Methodology and Clinical Application.

    PubMed

    Gorowska-Kowolik, Katarzyna; Chobot, Agata; Kwiecien, Jaroslaw

    2017-01-01

    Assessment of the liver function, and the need of constant monitoring of the organ's capacity, concerns not only patients with primary liver diseases, but also those at risk of hepatopathies secondary to other chronic diseases. Most commonly, the diagnostics is based on measurements of static biochemical parameters, which allow us to draw conclusions only indirectly about the function and the degree of damage of the organ. On the other hand, liver biopsy is an invasive procedure and therefore it is associated with a considerable risk of complications. Dynamic tests enable us to assess quantitatively the organ's functional reserve by analyzing the kinetics of the metabolization of the substrate by the liver. In practice applied are breath tests using substances such as aminopyrine, caffeine, methacetin, erythromycin (for assessment of the microsomal function); phenylalanine, galactose (for assessment of the cytosolic function); methionine, octanoate, ketoisocaproic acid (for assessment of the mitochondrial function). The test with 13 C methacetin belongs to the best described and most widely applied methods in noninvasive liver function assessment. Due to the rising availability of this method, knowledge concerning its limitations and controversies regarding the methodology, as well as its usefulness in chosen groups of patients, seems to be vital.

  8. Safety of coronary CT angiography and functional testing for stable chest pain in the PROMISE trial: A randomized comparison of test complications, incidental findings, and radiation dose.

    PubMed

    Lu, Michael T; Douglas, Pamela S; Udelson, James E; Adami, Elizabeth; Ghoshhajra, Brian B; Picard, Michael H; Roberts, Rhonda; Lee, Kerry L; Einstein, Andrew J; Mark, Daniel B; Velazquez, Eric J; Carter, William; Ridner, Michael; Al-Khalidi, Hussein R; Hoffmann, Udo

    Coronary computed tomography angiography (CTA) and functional testing strategies for stable chest pain yield similar outcomes; one aspect that may guide test choice is safety. We compared test safety (test complications, incidental findings, and effective radiation dose) between CTA and functional testing as-tested in PROMISE (PROspective Multicenter Imaging Study for Evaluation of Chest Pain). In the subgroup whose physicians intended nuclear stress over other functional tests if randomized to the functional arm, we compared radiation dose of CTA versus nuclear stress and identified characteristics associated with dose. Of 9470 patients, none had major and <1% had minor complications (CTA: 0.8% [37/4633] vs. functional: 0.6% [27/4837]). CTA identified more incidental findings (11.6% [539/4633] vs. 0.7% [34/4837], p < 0.001), most commonly pulmonary nodules (9.4%, 437/4633). CTA had similar 90-day cumulative radiation dose to functional testing. However, in the subgroup whose physicians intended nuclear stress (CTA 3147; nuclear 3203), CTA had lower median index test (8.8 vs. 12.6 mSv, p < 0.001) and 90-day cumulative (11.6 vs. 13.1 mSv, p < 0.001) dose, independent of patient characteristics. The lowest nuclear doses employed 1-day Tc-99m protocols (12.2 mSv). The lowest CTA doses were at sites performing ≥500 CTAs/year (6.9 mSv) and with advanced (latest available) CT scanners (5.5 mSv). Complications were negligibly rare for both CTA and functional testing. CTA detects more incidental findings. Compared to nuclear stress testing, CTA's lower radiation dose, independent of patient characteristics, makes it an attractive test choice. Radiation dose varies with imaging protocol, indicating opportunities to further reduce dose. (ClinicalTrials.gov number, NCT01174550). Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  9. Functional Testing Communication Equipment (Avionics).

    DTIC Science & Technology

    1980-07-31

    Yes No . Comment : 2. Were the facilities, test equipment, instrumentation, and support accommodations adequate to accomplish the test objectives...Yes No . Comment : 3. Have all data collected been reviewed for correctness and completeness? Yes No . Comment : 4. Were the test results compromised in...any way due to insufficient test planning? Yes No . Comment : 5. Were the test results compromised in any way due to test performance procedures? Yes No

  10. Functional linear models to test for differences in prairie wetland hydraulic gradients

    USGS Publications Warehouse

    Greenwood, Mark C.; Sojda, Richard S.; Preston, Todd M.; Swayne, David A.; Yang, Wanhong; Voinov, A.A.; Rizzoli, A.; Filatova, T.

    2010-01-01

    Functional data analysis provides a framework for analyzing multiple time series measured frequently in time, treating each series as a continuous function of time. Functional linear models are used to test for effects on hydraulic gradient functional responses collected from three types of land use in Northeastern Montana at fourteen locations. Penalized regression-splines are used to estimate the underlying continuous functions based on the discretely recorded (over time) gradient measurements. Permutation methods are used to assess the statistical significance of effects. A method for accommodating missing observations in each time series is described. Hydraulic gradients may be an initial and fundamental ecosystem process that responds to climate change. We suggest other potential uses of these methods for detecting evidence of climate change.

  11. An Alternative Methodology for Creating Parallel Test Forms Using the IRT Information Function.

    ERIC Educational Resources Information Center

    Ackerman, Terry A.

    The purpose of this paper is to report results on the development of a new computer-assisted methodology for creating parallel test forms using the item response theory (IRT) information function. Recently, several researchers have approached test construction from a mathematical programming perspective. However, these procedures require…

  12. Use of biochemical tests of placental function for improving pregnancy outcome.

    PubMed

    Heazell, Alexander E P; Whitworth, Melissa; Duley, Lelia; Thornton, Jim G

    2015-11-25

    The placenta has an essential role in determining the outcome of pregnancy. Consequently, biochemical measurement of placentally-derived factors has been suggested as a means to improve fetal and maternal outcome of pregnancy. To assess whether clinicians' knowledge of the results of biochemical tests of placental function is associated with improvement in fetal or maternal outcome of pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 July 2015) and reference lists of retrieved studies. Randomised, cluster-randomised or quasi-randomised controlled trials assessing the merits of the use of biochemical tests of placental function to improve pregnancy outcome.Studies were eligible if they compared women who had placental function tests and the results were available to their clinicians with women who either did not have the tests, or the tests were done but the results were not available to the clinicians. The placental function tests were any biochemical test of placental function carried out using the woman's maternal biofluid, either alone or in combination with other placental function test/s. Two review authors independently assessed trials for inclusion, extracted data and assessed trial quality. Authors of published trials were contacted for further information. Three trials were included, two quasi-randomised controlled trials and one randomised controlled trial. One trial was deemed to be at low risk of bias while the other two were at high risk of bias. Different biochemical analytes were measured - oestrogen was measured in one trial and the other two measured human placental lactogen (hPL). One trial did not contribute outcome data, therefore, the results of this review are based on two trials with 740 participants.There was no evidence of a difference in the incidence of death of a baby (risk ratio (RR) 0.88, 95% confidence interval (CI) 0.36 to 2.13, two trials, 740 participants (very low quality evidence)) or the

  13. Functional Performance and Associations between Performance Tests and Neurological Assessment Differ in Men and Women with Parkinson's Disease.

    PubMed

    Medijainen, Kadri; Pääsuke, Mati; Lukmann, Aet; Taba, Pille

    2015-01-01

    Neurological assessment of a patient with Parkinson's disease (PD) is expected to reflect upon functional performance. As women are known to report more limitations even for same observed functional performance level, present study was designed to examine whether associations between neurological assessments and functional performance differ across genders. 14 men and 14 women with PD participated. Functional performance was assessed by measuring walking speeds on 10-meter walk test (10MWT) and by performing timed-up-and-go-test (TUG). Neurological assessment included Hoehn and Yahr Scale (HY), Movement Disorders Society Unified Parkinson's Disease Rating Scale (MDS-UPDRS), Schwab and England Activities of Daily Living Scale (S-E), and Mini Mental State Examination (MMSE). In women with PD, Kendall's tau-b correlation analyses revealed significant correlations between functional performance tests and neurological assessment measures, with the exception in MMSE. No corresponding associations were found for men, although they demonstrated better functional performance, as expected. Men in similar clinical stage of the PD perform better on functional tests than women. Disease severity reflects upon functional performance differently in men and women with PD. Results indicate that when interpreting the assessment results of both functional performance and neurological assessment tests, the gender of the patient should be taken into consideration.

  14. Artificial vision: needs, functioning, and testing of a retinal electronic prosthesis.

    PubMed

    Chader, Gerald J; Weiland, James; Humayun, Mark S

    2009-01-01

    Hundreds of thousands around the world have poor vision or no vision at all due to inherited retinal degenerations (RDs) like retinitis pigmentosa (RP). Similarly, millions suffer from vision loss due to age-related macular degeneration (AMD). In both of these allied diseases, the primary target for pathology is the retinal photoreceptor cells that dysfunction and die. Secondary neurons though are relatively spared. To replace photoreceptor cell function, an electronic prosthetic device can be used such that retinal secondary neurons receive a signal that simulates an external visual image. The composite device has a miniature video camera mounted on the patient's eyeglasses, which captures images and passes them to a microprocessor that converts the data to an electronic signal. This signal, in turn, is transmitted to an array of electrodes placed on the retinal surface, which transmits the patterned signal to the remaining viable secondary neurons. These neurons (ganglion, bipolar cells, etc.) begin processing the signal and pass it down the optic nerve to the brain for final integration into a visual image. Many groups in different countries have different versions of the device, including brain implants and retinal implants, the latter having epiretinal or subretinal placement. The device furthest along in development is an epiretinal implant sponsored by Second Sight Medical Products (SSMP). Their first-generation device had 16 electrodes with human testing in a Phase 1 clinical trial beginning in 2002. The second-generation device has 60+ electrodes and is currently in Phase 2/3 clinical trial. Increased numbers of electrodes are planned for future versions of the device. Testing of the device's efficacy is a challenge since patients admitted into the trial have little or no vision. Thus, methods must be developed that accurately and reproducibly record small improvements in visual function after implantation. Standard tests such as visual acuity, visual

  15. Muscle Force-Velocity Relationships Observed in Four Different Functional Tests.

    PubMed

    Zivkovic, Milena Z; Djuric, Sasa; Cuk, Ivan; Suzovic, Dejan; Jaric, Slobodan

    2017-02-01

    The aims of the present study were to investigate the shape and strength of the force-velocity relationships observed in different functional movement tests and explore the parameters depicting force, velocity and power producing capacities of the tested muscles. Twelve subjects were tested on maximum performance in vertical jumps, cycling, bench press throws, and bench pulls performed against different loads. Thereafter, both the averaged and maximum force and velocity variables recorded from individual trials were used for force-velocity relationship modeling. The observed individual force-velocity relationships were exceptionally strong (median correlation coefficients ranged from r = 0.930 to r = 0.995) and approximately linear independently of the test and variable type. Most of the relationship parameters observed from the averaged and maximum force and velocity variable types were strongly related in all tests (r = 0.789-0.991), except for those in vertical jumps (r = 0.485-0.930). However, the generalizability of the force-velocity relationship parameters depicting maximum force, velocity and power of the tested muscles across different tests was inconsistent and on average moderate. We concluded that the linear force-velocity relationship model based on either maximum or averaged force-velocity data could provide the outcomes depicting force, velocity and power generating capacity of the tested muscles, although such outcomes can only be partially generalized across different muscles.

  16. Muscle Force-Velocity Relationships Observed in Four Different Functional Tests

    PubMed Central

    Zivkovic, Milena Z.; Djuric, Sasa; Cuk, Ivan; Suzovic, Dejan; Jaric, Slobodan

    2017-01-01

    Abstract The aims of the present study were to investigate the shape and strength of the force-velocity relationships observed in different functional movement tests and explore the parameters depicting force, velocity and power producing capacities of the tested muscles. Twelve subjects were tested on maximum performance in vertical jumps, cycling, bench press throws, and bench pulls performed against different loads. Thereafter, both the averaged and maximum force and velocity variables recorded from individual trials were used for force–velocity relationship modeling. The observed individual force-velocity relationships were exceptionally strong (median correlation coefficients ranged from r = 0.930 to r = 0.995) and approximately linear independently of the test and variable type. Most of the relationship parameters observed from the averaged and maximum force and velocity variable types were strongly related in all tests (r = 0.789-0.991), except for those in vertical jumps (r = 0.485-0.930). However, the generalizability of the force-velocity relationship parameters depicting maximum force, velocity and power of the tested muscles across different tests was inconsistent and on average moderate. We concluded that the linear force-velocity relationship model based on either maximum or averaged force-velocity data could provide the outcomes depicting force, velocity and power generating capacity of the tested muscles, although such outcomes can only be partially generalized across different muscles. PMID:28469742

  17. Comparison of fecal elastase-1 and pancreatic function testing in children.

    PubMed

    Wali, Prateek D; Loveridge-Lenza, Beth; He, Zhaoping; Horvath, Karoly

    2012-02-01

    The fecal pancreatic elastase-1 (FE-1) test is considered a simple, noninvasive, indirect measure of pancreatic function. We aimed to evaluate the performance of the FE-1 test compared with the direct pancreatic function test (PFT) with secretin stimulation in children. Data of 70 children (6 months-17 years of age) who had both FE-1 test and PFT were analyzed. The average FE-1 concentration was 403 ± 142 μg/g. Eleven children had concentrations below 200  μg/g, 23 between 201 to 500 μg/g, and 36 were above 500 μg/g. The average pancreatic elastase activity measured on direct stimulation was 49.1 ± 38.6  μmol · min (-1)· ml(-1) and 11 children had activity below the established cutoff (10.5 μmol · min(-1) · ml(-1)). Among the 11 children with pathologic PFT, 7 had normal FE-1, 4 were in the intermediate range (201-500 μg/g), and none were in the low range (<200 μg/g). Among the 59 children with normal direct PFT 11 (19%) had pathologic (<200 μg/g) and 19 (32%) had intermediate FE-1 tests. Twenty-nine children had both normal FE-1 concentration and normal PFT, giving a negative predictive value of 80%. The correlation between pancreatic elastase activity and FE-1 concentration was poor (r = 0.190). The sensitivity of the FE-1 test was found to be 41.7%, whereas the specificity was 49.2%. The positive predictive value of the FE-1 test was only 14%. The FE-1 test is a simple, noninvasive, indirect method; however, ordering physicians should be aware of its limitations. It can give false-positive results and has low sensitivity in children with mild pancreatic insufficiency without cystic fibrosis and in those with isolated pancreatic enzyme deficiencies.

  18. The pharmacists' role in improving guideline compliance for thyroid function testing in patients with heart failure.

    PubMed

    Ziman, Melanie E; Bui, Hien T; Smith, Craig S; Tsukiji, Lori A; Asmatey, Veda M; Chu, Steven B; Miano, John S

    2012-04-01

    This single-center retrospective pilot program's objective was to utilize outpatient pharmacists to improve laboratory test adherence in chronic heart failure (CHF) patients overdue for thyroid function testing, thereby demonstrating the value of the outpatient pharmacist and justifying possible clinical role expansion. Thyroid disorders may contribute to CHF development, progression, and exacerbation. Testing is the standard of care in CHF patients per American Heart Association's 2009 Guidelines. Delinquency was defined as labs not conducted within 1 year in patients with euthyroid history, within 6 months in patients with thyroid dysfunction, abnormal labs at any time without follow-up, or lab absence after thyroid medication initiation, adjustment, or discontinuation. Targeted 80 nonpregnant adult CHF patients with delinquent thyroid function tests were counseled to get thyroid labs at point of sale, via telephone, e-mail, or letter. In collaboration with physicians, pharmacists ordered thyroid-stimulating hormone (TSH) and free T4 (FT4) labs. For patients with abnormal laboratory results, pharmacists coordinated drug therapy and follow-up labs. Data were collected from November 1, 2009 to March 30, 2010. Seventy-two patients (90%) previously delinquent for thyroid function testing received relevant thyroid labs. Ten patients (12.5%) with abnormal thyroid function tests not on prior drug therapy received treatment.

  19. Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning

    ERIC Educational Resources Information Center

    Li, Zhushan

    2014-01-01

    Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…

  20. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    NASA Astrophysics Data System (ADS)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  1. Measurement of global functional performance in patients with rheumatoid arthritis using rheumatology function tests

    PubMed Central

    Escalante, Agustín; Haas, Roy W; del Rincón, Inmaculada

    2004-01-01

    Outcome assessment in patients with rheumatoid arthritis (RA) includes measurement of physical function. We derived a scale to quantify global physical function in RA, using three performance-based rheumatology function tests (RFTs). We measured grip strength, walking velocity, and shirt button speed in consecutive RA patients attending scheduled appointments at six rheumatology clinics, repeating these measurements after a median interval of 1 year. We extracted the underlying latent variable using principal component factor analysis. We used the Bayesian information criterion to assess the global physical function scale's cross-sectional fit to criterion standards. The criteria were joint tenderness, swelling, and deformity, pain, physical disability, current work status, and vital status at 6 years after study enrolment. We computed Guyatt's responsiveness statistic for improvement according to the American College of Rheumatology (ACR) definition. Baseline functional performance data were available for 777 patients, and follow-up data were available for 681. Mean ± standard deviation for each RFT at baseline were: grip strength, 14 ± 10 kg; walking velocity, 194 ± 82 ft/min; and shirt button speed, 7.1 ± 3.8 buttons/min. Grip strength and walking velocity departed significantly from normality. The three RFTs loaded strongly on a single factor that explained ≥70% of their combined variance. We rescaled the factor to vary from 0 to 100. Its mean ± standard deviation was 41 ± 20, with a normal distribution. The new global scale had a stronger fit than the primary RFT to most of the criterion standards. It correlated more strongly with physical disability at follow-up and was more responsive to improvement defined according to the ACR20 and ACR50 definitions. We conclude that a performance-based physical function scale extracted from three RFTs has acceptable distributional and measurement properties and is responsive to clinically meaningful change. It

  2. Changes in cardiopulmonary function in normal adults after the Rockport 1 mile walking test: a preliminary study.

    PubMed

    Kim, Kyoung; Lee, Hye-Young; Lee, Do-Youn; Nam, Chan-Woo

    2015-08-01

    [Purpose] The purpose of this study was to investigate the changes of cardiopulmonary function in normal adults after the Rockport 1 mile walking test. [Subjects and Methods] University students (13 males and 27 females) participated in this study. Before and after the Rockport 1 mile walking test, pulmonary function, respiratory pressure, and maximal oxygen uptake were measured. [Results] Significant improvements in forced vital capacity and maximal inspiratory pressure were observed after the Rockport 1 mile walking test in males, and significant improvements in forced vital capacity, forced expiratory volume at 1 s, maximal inspiratory pressure, and maximal expiratory pressure were observed after the Rockport 1 mile walking test in females. However, the maximal oxygen uptake was not significantly different. [Conclusion] Our findings indicate that the Rockport 1 mile walking test changes cardiopulmonary function in males and females, and that it may improve cardiopulmonary function in middle-aged and older adults and provide basic data on cardiopulmonary endurance.

  3. Changes in cardiopulmonary function in normal adults after the Rockport 1 mile walking test: a preliminary study

    PubMed Central

    Kim, Kyoung; Lee, Hye-Young; Lee, Do-Youn; Nam, Chan-Woo

    2015-01-01

    [Purpose] The purpose of this study was to investigate the changes of cardiopulmonary function in normal adults after the Rockport 1 mile walking test. [Subjects and Methods] University students (13 males and 27 females) participated in this study. Before and after the Rockport 1 mile walking test, pulmonary function, respiratory pressure, and maximal oxygen uptake were measured. [Results] Significant improvements in forced vital capacity and maximal inspiratory pressure were observed after the Rockport 1 mile walking test in males, and significant improvements in forced vital capacity, forced expiratory volume at 1 s, maximal inspiratory pressure, and maximal expiratory pressure were observed after the Rockport 1 mile walking test in females. However, the maximal oxygen uptake was not significantly different. [Conclusion] Our findings indicate that the Rockport 1 mile walking test changes cardiopulmonary function in males and females, and that it may improve cardiopulmonary function in middle-aged and older adults and provide basic data on cardiopulmonary endurance. PMID:26356048

  4. Ultrasound versus liver function tests for diagnosis of common bile duct stones.

    PubMed

    Gurusamy, Kurinchi Selvan; Giljaca, Vanja; Takwoingi, Yemisi; Higgie, David; Poropat, Goran; Štimac, Davor; Davidson, Brian R

    2015-02-26

    Ultrasound and liver function tests (serum bilirubin and serum alkaline phosphatase) are used as screening tests for the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ultrasound and liver function tests. To determine and compare the accuracy of ultrasound versus liver function tests for the diagnosis of common bile duct stones. We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. We searched the references of included studies to identify further studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects, Health Technology Assessment, Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ultrasound, serum bilirubin, or serum alkaline phosphatase. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test result, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test result as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. Two authors independently collected data from

  5. Unified Sequence-Based Association Tests Allowing for Multiple Functional Annotations and Meta-analysis of Noncoding Variation in Metabochip Data.

    PubMed

    He, Zihuai; Xu, Bin; Lee, Seunggeun; Ionita-Laza, Iuliana

    2017-09-07

    Substantial progress has been made in the functional annotation of genetic variation in the human genome. Integrative analysis that incorporates such functional annotations into sequencing studies can aid the discovery of disease-associated genetic variants, especially those with unknown function and located outside protein-coding regions. Direct incorporation of one functional annotation as weight in existing dispersion and burden tests can suffer substantial loss of power when the functional annotation is not predictive of the risk status of a variant. Here, we have developed unified tests that can utilize multiple functional annotations simultaneously for integrative association analysis with efficient computational techniques. We show that the proposed tests significantly improve power when variant risk status can be predicted by functional annotations. Importantly, when functional annotations are not predictive of risk status, the proposed tests incur only minimal loss of power in relation to existing dispersion and burden tests, and under certain circumstances they can even have improved power by learning a weight that better approximates the underlying disease model in a data-adaptive manner. The tests can be constructed with summary statistics of existing dispersion and burden tests for sequencing data, therefore allowing meta-analysis of multiple studies without sharing individual-level data. We applied the proposed tests to a meta-analysis of noncoding rare variants in Metabochip data on 12,281 individuals from eight studies for lipid traits. By incorporating the Eigen functional score, we detected significant associations between noncoding rare variants in SLC22A3 and low-density lipoprotein and total cholesterol, associations that are missed by standard dispersion and burden tests. Copyright © 2017 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  6. Development of Internet-Based Tasks for the Executive Function Performance Test.

    PubMed

    Rand, Debbie; Lee Ben-Haim, Keren; Malka, Rachel; Portnoy, Sigal

    The Executive Function Performance Test (EFPT) is a reliable and valid performance-based tool to assess executive functions (EFs). This study's objective was to develop and verify two Internet-based tasks for the EFPT. A cross-sectional study assessed the alternate-form reliability of the Internet-based bill-paying and telephone-use tasks in healthy adults and people with subacute stroke (Study 1). It also sought to establish the tasks' criterion reliability for assessing EF deficits by correlating performance with that on the Trail Making Test in five groups: healthy young adults, healthy older adults, people with subacute stroke, people with chronic stroke, and young adults with attention deficit hyperactivity disorder (Study 2). The alternative-form reliability and initial construct validity for the Internet-based bill-paying task were verified. Criterion validity was established for both tasks. The Internet-based tasks are comparable to the original EFPT tasks and can be used for assessment of EF deficits. Copyright © 2018 by the American Occupational Therapy Association, Inc.

  7. Formal functional test designs with a test representation language

    NASA Technical Reports Server (NTRS)

    Hops, J. M.

    1993-01-01

    The application of the category-partition method to the test design phase of hardware, software, or system test development is discussed. The method provides a formal framework for reducing the total number of possible test cases to a minimum logical subset for effective testing. An automatic tool and a formal language were developed to implement the method and produce the specification of test cases.

  8. Tuboimpedance: A New Test of Eustachian Tube Function.

    PubMed

    Smith, Matthew E; Zou, Charlie C; Blythe, Andrew J C; Tysome, James R

    2017-04-01

    Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.

  9. Gait speed in older people: an easy test for detecting cognitive impairment, functional independence, and health state.

    PubMed

    Garcia-Pinillos, Felipe; Cozar-Barba, Manuela; Munoz-Jimenez, Marcos; Soto-Hermoso, Victor; Latorre-Roman, Pedro

    2016-05-01

    With ageing, physical and cognitive functions become impaired. Analyzing and determining the association between both functions can facilitate the prevention and diagnosis of associated problems. Some previous works have proposed batteries of physical performance tests to determine both physical and cognitive functions. However, only a few studies have used the gait speed (GS) test as a tool to evaluate parameters representative of health in the elderly such as functionality, mobility, independence, autonomy, and comorbidity. Therefore, the aim of this study was to determine the association between physical and cognitive functions in older people (over 65 years old) and to detect the most appropriate physical test to assess cognitive impairment, functional independence, comorbidity, and perceived health in this population. One hundred six older adults (38 men, 68 women) participated voluntarily in this cross-sectional study. To assess the physical function handgrip strength, GS, 30-s chair stand tests, and body composition analysis were performed. To evaluate cognitive function, the Mini-Mental State Examination, Barthel index, and Charlson index were employed. No significant differences (P ≥ 0.05) between sexes were found. Multiple regression analysis of the Mini-Mental State Examination and physical fitness variables, adjusted for age and sex, indicates that GS is a predictor of Mini-Mental State Examination score (R(2) = 0.138). The results showed that GS is an important predictor of functional capacity (physical and cognitive function) in adults over 65 years old. © 2015 The Authors. Psychogeriatrics © 2015 Japanese Psychogeriatric Society.

  10. LOWER EXTREMITY FUNCTIONAL TESTS AND RISK OF INJURY IN DIVISION III COLLEGIATE ATHLETES

    PubMed Central

    Heiderscheit, Bryan C.; Manske, Robert C.; Niemuth, Paul E.; Rauh, Mitchell J.

    2013-01-01

    Purpose/Background: Functional tests have been used primarily to assess an athlete's fitness or readiness to return to sport. The purpose of this prospective cohort study was to determine the ability of the standing long jump (SLJ) test, the single‐leg hop (SLH) for distance test, and the lower extremity functional test (LEFT) as preseason screening tools to identify collegiate athletes who may be at increased risk for a time‐loss sports‐related low back or lower extremity injury. Methods: A total of 193 Division III athletes from 15 university teams (110 females, age 19.1 ± 1.1 y; 83 males, age 19.5 ± 1.3 y) were tested prior to their sports seasons. Athletes performed the functional tests in the following sequence: SLJ, SLH, LEFT. The athletes were then prospectively followed during their sports season for occurrence of low back or LE injury. Results: Female athletes who completed the LEFT in $118 s were 6 times more likely (OR=6.4, 95% CI: 1.3, 31.7) to sustain a thigh or knee injury. Male athletes who completed the LEFT in #100 s were more likely to experience a time‐loss injury to the low back or LE (OR=3.2, 95% CI: 1.1, 9.5) or a foot or ankle injury (OR=6.7, 95% CI: 1.5, 29.7) than male athletes who completed the LEFT in 101 s or more. Female athletes with a greater than 10% side‐to‐side asymmetry between SLH distances had a 4‐fold increase in foot or ankle injury (cut point: >10%; OR=4.4, 95% CI: 1.2, 15.4). Male athletes with SLH distances (either leg) at least 75% of their height had at least a 3‐fold increase (OR=3.6, 95% CI: 1.2, 11.2 for the right LE; OR=3.6, 95% CI: 1.2, 11.2 for left LE) in low back or LE injury. Conclusions: The LEFT and the SLH tests appear useful in identifying Division III athletes at risk for a low back or lower extremity sports injury. Thus, these tests warrant further consideration as preparticipatory screening examination tools for sport injury in this population. Clinical Relevance: The single‐leg hop for

  11. Simple and easy assessment of falling risk in the elderly by functional reach test using elastic stick.

    PubMed

    Demura, Shin-Ichi; Yamada, Takayoshi

    2007-10-01

    Dynamic balance ability related to maintaining postural stability during movement is closely tied to fall risk in the elderly. The functional reach (FR) test has been developed to evaluate their dynamic balance. Although a simple and new FR test using an elastic stick has been proposed by modifying the above original FR test, the abilities related to both FR tests are judged to differ because of the large difference in the testing method. This study aimed to compare center of gravity fluctuation, muscle activity and functional reach distance as measured by the original FR test and the elastic stick FR test. First, reach distance, back/forth and right/left moving distance of the center of gravity, and activity of the lower leg muscles (soleus and tibialis anterior) were compared between both tests based on data obtained from 30 young male adults. All parameters except for the right/left moving distance were significantly larger in the elastic stick FR test. Next, the reach distance was examined in both FR tests using 53 elderly subjects; it was significantly longer in the elastic stick FR test, but showed no significant sex difference. The reach distance in both tests was significantly shorter (about 7 cm) in the elderly than in young adults. In conclusion, the elastic stick FR test involves greater leg muscle strength exertion and forward transferring of the center of gravity as compared with the original FR test. Because the elastic stick FR test relates largely to leg muscle function and equilibrium function, it may be more useful for evaluating the dynamic balance ability of the elderly.

  12. Utility and reliability of non-invasive muscle function tests in high-fat-fed mice.

    PubMed

    Martinez-Huenchullan, Sergio F; McLennan, Susan V; Ban, Linda A; Morsch, Marco; Twigg, Stephen M; Tam, Charmaine S

    2017-07-01

    What is the central question of this study? Non-invasive muscle function tests have not been validated for use in the study of muscle performance in high-fat-fed mice. What is the main finding and its importance? This study shows that grip strength, hang wire and four-limb hanging tests are able to discriminate the muscle performance between chow-fed and high-fat-fed mice at different time points, with grip strength being reliable after 5, 10 and 20 weeks of dietary intervention. Non-invasive tests are commonly used for assessing muscle function in animal models. The value of these tests in obesity, a condition where muscle strength is reduced, is unclear. We investigated the utility of three non-invasive muscle function tests, namely grip strength (GS), hang wire (HW) and four-limb hanging (FLH), in C57BL/6 mice fed chow (chow group, n = 48) or a high-fat diet (HFD group, n = 48) for 20 weeks. Muscle function tests were performed at 5, 10 and 20 weeks. After 10 and 20 weeks, HFD mice had significantly reduced GS (in newtons; mean ± SD: 10 weeks chow, 1.89 ± 0.1 and HFD, 1.79 ± 0.1; 20 weeks chow, 1.99 ± 0.1 and HFD, 1.75 ± 0.1), FLH [in seconds per gram body weight; median (interquartile range): 10 weeks chow, 2552 (1337-4964) and HFD, 1230 (749-1994); 20 weeks chow, 2048 (765-3864) and HFD, 1036 (717-1855)] and HW reaches [n; median (interquartile range): 10 weeks chow, 4 (2-5) and HFD, 2 (1-3); 20 weeks chow, 3 (1-5) and HFD, 1 (0-2)] and higher falls [n; median (interquartile range): 10 weeks chow, 0 (0-2) and HFD, 3 (1-7); 20 weeks chow, 1 (0-4) and HFD, 8 (5-10)]. Grip strength was reliable in both dietary groups [intraclass correlation coefficient (ICC) = 0.5-0.8; P < 0.05], whereas FLH showed good reliability in chow (ICC = 0.7; P < 0.05) but not in HFD mice after 10 weeks (ICC < 0.5). Our data demonstrate that non-invasive muscle function tests are valuable and reliable tools for assessment of muscle strength and

  13. Analysis of Saccular Function With Vestibular Evoked Myogenic Potential Test in Meniere's Disease.

    PubMed

    Dabiri, Sasan; Yazdani, Nasrin; Esfahani, Mahdis; Tari, Niloufar; Adil, Susan; Mahvi, Zahra; Rezazadeh, Nima

    2017-02-01

    Meniere's disease is the disorder of inner ear characterized by vertigo, tinnitus and sensorineural hearing loss. The vestibular evoked myogenic potential (VEMP) test could be useful in the analysis of saccular function, and diagnosis of Meniere's disease. In this study, we've analyzed the saccular function, using VEMP test in different groups of Meniere's disease. Patients were categorized as possible, probable or definite Meniere's disease groups according to the guideline of American Academy of Otolaryngology-Head and Neck Surgery. The exclusion criteria were neuromuscular system diseases, diseases of central nervous system, inner ear disorders, conductive hearing loss, a history of ototoxic drug consumption, being a drug abuser and a positive history of inner ear surgery or manipulations. The VEMP test is the recording of positive and negative waves from sternocleidomastoid muscle that is made by an auditory click to the ear. From the total of 100 patients, the waves of VEMP test was seen in 59 patients which 19 patients had abnormal amplitude, and latency and 40 patients were with normally recorded waves. There was a significant relationship between the severity of hearing loss and a VEMP test without any recorded waves. Most of the cases with 'no wave recorded' VEMP test, were patients with severe hearing loss. However, there wasn't any relation between the pattern of hearing loss and 'no wave recorded' VEMP test. VEMP test could be a valuable diagnostic clue especially in patients with definite Meniere's disease.

  14. Development of an item bank and computer adaptive test for role functioning.

    PubMed

    Anatchkova, Milena D; Rose, Matthias; Ware, John E; Bjorner, Jakob B

    2012-11-01

    Role functioning (RF) is a key component of health and well-being and an important outcome in health research. The aim of this study was to develop an item bank to measure impact of health on role functioning. A set of different instruments including 75 newly developed items asking about the impact of health on role functioning was completed by 2,500 participants. Established item response theory methods were used to develop an item bank based on the generalized partial credit model. Comparison of group mean bank scores of participants with different self-reported general health status and chronic conditions was used to test the external validity of the bank. After excluding items that did not meet established requirements, the final item bank consisted of a total of 64 items covering three areas of role functioning (family, social, and occupational). Slopes in the bank ranged between .93 and 4.37; the mean threshold range was -1.09 to -2.25. Item bank-based scores were significantly different for participants with and without chronic conditions and with different levels of self-reported general health. An item bank assessing health impact on RF across three content areas has been successfully developed. The bank can be used for development of short forms or computerized adaptive tests to be applied in the assessment of role functioning as one of the common denominators across applications of generic health assessment.

  15. A virtual shopping test for realistic assessment of cognitive function.

    PubMed

    Okahashi, Sayaka; Seki, Keiko; Nagano, Akinori; Luo, Zhiwei; Kojima, Maki; Futaki, Toshiko

    2013-06-18

    Cognitive dysfunction caused by brain injury often prevents a patient from achieving a healthy and high quality of life. By now, each cognitive function is assessed precisely by neuropsychological tests. However, it is also important to provide an overall assessment of the patients' ability in their everyday life. We have developed a Virtual Shopping Test (VST) using virtual reality technology. The objective of this study was to clarify 1) the significance of VST by comparing VST with other conventional tests, 2) the applicability of VST to brain-damaged patients, and 3) the performance of VST in relation to age differences. The participants included 10 patients with brain damage, 10 age-matched healthy subjects for controls, 10 old healthy subjects, and 10 young healthy subjects. VST and neuropsychological tests/questionnaires about attention, memory and executive function were conducted on the patients, while VST and the Mini-Mental State Examination (MMSE) were conducted on the controls and healthy subjects. Within the VST, the participants were asked to buy four items in the virtual shopping mall quickly in a rational way. The score for evaluation included the number of items bought correctly, the number of times to refer to hints, the number of movements between shops, and the total time spent to complete the shopping. Some variables on VST correlated with the scores of conventional assessment about attention and everyday memory. The mean number of times referring to hints and the mean number of movements were significantly larger for the patients with brain damage, and the mean total time was significantly longer for the patients than for the controls. In addition, the mean total time was significantly longer for the old than for the young. The results suggest that VST is able to evaluate the ability of attention and everyday memory in patients with brain damage. The time of VST is increased by age.

  16. NASA's Functional Task Test: Effects of Spaceflight and Six Degree Head-Down Bedrest on Dynamic Postural Stability

    NASA Technical Reports Server (NTRS)

    Taylor, L. C.; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2015-01-01

    The goals of the Functional Task Test (FTT) study were to determine the effects of spaceflight on functional tests that are representative of critical exploration mission tasks and to identify the physiological factors that contribute to decrements in performance.

  17. Individual muscle control using an exoskeleton robot for muscle function testing.

    PubMed

    Ueda, Jun; Ming, Ding; Krishnamoorthy, Vijaya; Shinohara, Minoru; Ogasawara, Tsukasa

    2010-08-01

    Healthy individuals modulate muscle activation patterns according to their intended movement and external environment. Persons with neurological disorders (e.g., stroke and spinal cord injury), however, have problems in movement control due primarily to their inability to modulate their muscle activation pattern in an appropriate manner. A functionality test at the level of individual muscles that investigates the activity of a muscle of interest on various motor tasks may enable muscle-level force grading. To date there is no extant work that focuses on the application of exoskeleton robots to induce specific muscle activation in a systematic manner. This paper proposes a new method, named "individual muscle-force control" using a wearable robot (an exoskeleton robot, or a power-assisting device) to obtain a wider variety of muscle activity data than standard motor tasks, e.g., pushing a handle by hand. A computational algorithm systematically computes control commands to a wearable robot so that a desired muscle activation pattern for target muscle forces is induced. It also computes an adequate amount and direction of a force that a subject needs to exert against a handle by his/her hand. This individual muscle control method enables users (e.g., therapists) to efficiently conduct neuromuscular function tests on target muscles by arbitrarily inducing muscle activation patterns. This paper presents a basic concept, mathematical formulation, and solution of the individual muscle-force control and its implementation to a muscle control system with an exoskeleton-type robot for upper extremity. Simulation and experimental results in healthy individuals justify the use of an exoskeleton robot for future muscle function testing in terms of the variety of muscle activity data.

  18. Esophageal function testing using multichannel intraluminal impedance.

    PubMed

    Srinivasan, R; Vela, M F; Katz, P O; Tutuian, R; Castell, J A; Castell, D O

    2001-03-01

    Multichannel intraluminal impedance (MII) is a new technique for evaluation of bolus transport. We evaluated esophageal function using bolus transport time (BTT) and contraction wave velocity (CWV) of liquid, semisolid, and solid boluses. Ten healthy subjects underwent MII swallow evaluation with various boluses of sterile water (pH 5), applesauce, three different sized marshmallows, and iced and 130 degrees F water. The effect of bethanechol was also studied. There was no difference in BTT or CWV for all water volumes from 1 to 20 ml. There was significant linear increase of BTT with progressively larger volumes of applesauce, and BTT of applesauce was longer than for water. BTT was significantly longer with large marshmallows vs. small and medium and was longer than for water. BTT for iced water was similar to 130 degrees F water. Applesauce showed a significant linear decrease of CWV with progressively larger volumes and was slower than water. Marshmallow showed significantly slower CWV with the large vs. small, and CWV for ice water was significantly slower than 130 degrees F water. Therefore, BTT of liquid is constant, whereas BTT of semisolid and solid are volume dependent and longer than liquids. CWV of semisolids and solids are slower than liquids. CWV of cold liquids is slower than warm liquids. MII can be used as a discriminating test of esophageal function.

  19. Assessment of platelet function in healthy cats in response to commonly prescribed antiplatelet drugs using three point-of-care platelet function tests.

    PubMed

    Ho, Kimberly K; Abrams-Ogg, Anthony Cg; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L

    2017-06-01

    Objectives The objective was to determine if decreased platelet function could be detected after treatment with aspirin and/or clopidogrel in healthy cats using three point-of-care platelet function tests that evaluate platelet function by different methods: Multiplate (by impedance), Platelet Function Analyzer 100 (by mechanical aperture closure) and Plateletworks (by platelet counting). Methods Thirty-six healthy cats were randomly assigned to receive one of three oral treatments over an 8 day period: (1) aspirin 5 mg q72h; (2) aspirin 20.25 mg q72h; or (3) clopidogrel 18.75 mg q24h. Cats treated with 5 and 20.25 mg aspirin also received clopidogrel on days 4-8. Platelet aggregation in response to adenosine diphosphate and collagen ± arachidonic acid was assessed on days 1 (baseline), 4 and 8. Aspirin and clopidogrel metabolites were measured by high-performance liquid chromatography. Platelet function in response to treatment was analyzed by ANCOVA, linear regression and Spearman correlation. Results The only solitary aspirin effect was detected using Plateletworks with collagen in cats treated with 20.25 mg. The only effect detected by Multiplate was using arachidonic acid in cats treated with both aspirin 20.25 mg and clopidogrel. All clopidogrel treatment effects were detected by Platelet Function Analyzer 100, Plateletworks (adenosine diphosphate) and Plateletworks (collagen). Drug metabolites were present in all cats, but concentrations were minimally correlated to platelet function test results. Conclusions and relevance Platelet Function Analyzer 100 and Plateletworks using adenosine diphosphate ± collagen agonists may be used to detect decreased platelet function in response to clopidogrel treatment. Either aspirin is not as effective an antiplatelet drug as clopidogrel, or the tests used were not optimal to measure aspirin effect. Cats with heart disease are commonly prescribed antiplatelet drugs to decrease the risk of aortic thromboembolism

  20. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults.

    PubMed

    Piper, Brian J; Mueller, Shane T; Geerken, Alexander R; Dixon, Kyle L; Kroliczak, Gregory; Olsen, Reid H J; Miller, Jeremy K

    2015-01-01

    Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18-22). Study II evaluated test-retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18-22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen's d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance.

  1. Prevalence and factors associated with the presence of abnormal function liver tests in patients with ulcerative colitis.

    PubMed

    Yamamoto-Furusho, Jesús K; Sánchez-Osorio, Magdalena; Uribe, Misael

    2010-01-01

    To investigate the prevalence of abnormal function liver tests and risk factors associated with their development in Mexican patients with UC. A total of 200 patients with confirmed diagnosis of UC were evaluated prospectively during a one year period from January 1, 2007 to December 31, 2008. A total of 94 females and 106 males patients with UC were analyzed. The age at diagnosis was 31.4 ± 13.2 years and the mean of disease duration was 6.7 ± 5.2 years. We found a high prevalence of abnormal function livers tests in 40% of UC patients. The pattern of abnormal function liver test was hepatitis in 70%, cholestatic (20%) and mixed (10%). The most common cause of abnormal function liver test was transient elevation in 50 patients (63%) followed by fatty liver disease (11.2%), primary sclerosing cholangitis (6.3%), drug-toxicity (6%) and others (13.5%) including chronic hepatitis C, total parenteral nutrition, granulomatous and ischemic hepatitis. In the multivariate logistic regression model, active disease, colectomy and abdominal sepsis were factors that persisted associated with the development of abnormal liver tests in UC patients. A high prevalence of abnormal function liver tests (40%) was found in Mexican UC patients is likely to be related to active disease, colectomy and the presence of sepsis.

  2. Efficacy and safety of chloral hydrate sedation in infants for pulmonary function tests.

    PubMed

    Wandalsen, Gustavo Falbo; Lanza, Fernanda de Cordoba; Nogueira, Márcia Cristina Pires; Solé, Dirceu

    2016-12-01

    To describe the efficacy and safety of chloral hydrate sedation in infants for pulmonary function tests. All sedation attempts for pulmonary function tests in infants carried out between June 2007 and August 2014 were evaluated. Obstructive sleep apnea and heart disease were contraindications to the exams. Anthropometric data, exam indication, used dose, outcomes of sedation and clinical events were recorded and described. The sedation attempts in 277 infants (165 boys) with a median age of 51.5 weeks of life (14 to 182 weeks) were evaluated. The main indication for the tests was recurrent wheezing (56%) and the chloral hydrate dose ranged from 50 to 80mg/kg (orally). Eighteen (6.5%) infants had some type of clinical complication, with the most frequent being cough and/or airway secretion (1.8%); respiratory distress (1.4%) and vomiting (1.1%). A preterm infant had bradycardia for approximately 15 minutes, which was responsive to tactile stimulation. All observed adverse effects were transient and there was no need for resuscitation or use of injectable medications. The data demonstrated that chloral hydrate at the employed doses is a safe and effective medicament for sedation during short procedures in infants, such as pulmonary function tests. Because of the possibility of severe adverse events, recommendations on doses and contraindications should be strictly followed and infants should be monitored by trained staff. Copyright © 2016 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults

    PubMed Central

    Mueller, Shane T.; Geerken, Alexander R.; Dixon, Kyle L.; Kroliczak, Gregory; Olsen, Reid H.J.; Miller, Jeremy K.

    2015-01-01

    Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18–22). Study II evaluated test–retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18–22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen’s d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance. PMID:26713233

  4. Older people experiencing homelessness show marked impairment on tests of frontal lobe function.

    PubMed

    Rogoz, Astrid; Burke, David

    2016-03-01

    Reported rates of mild and moderate cognitive impairment in older people experiencing homelessness range from 5-80%. The objective of this study was to determine the prevalence and characteristics of cognitive impairment in older people experiencing homelessness in the inner city of Sydney, Australia. Men and women experiencing homelessness aged 45 years and over in the inner city were screened for cognitive impairment. Participants who scored 26 or below on the mini-mental state examination and/or were impaired on any one of the clock-drawing test, the verbal fluency test and the trail-making test, part B were then assessed with a semi-structured interview, including the 21-item Depression Anxiety Stress Scale and the 12-item General Health Questionnaire. Screening of 144 men and 27 women aged between 45 years and 93 years identified cognitive impairment in 78%. Subsequently, high rates of mental and physical illness were identified, and 75% of subjects who were cognitively impaired performed poorly on frontal lobe tests. The trail-making test, part B was the most sensitive measure of frontal function. This study demonstrated that a large majority of older people experiencing homelessness, in the inner city of a high-income country, showed impairment on tests of frontal lobe function, a finding that could have significant implications for any medical or psychosocial intervention. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Pulmonary Function Testing in Children

    MedlinePlus

    ... breathing test. About 15 minutes after taking the medicine, your child will repeat the breathing test. The results from ... the first test to find out if the medicine has improved your child’s breathing. Why shouldn’t I give my child ...

  6. Consistency tests for the extraction of the Boer-Mulders and Sivers functions

    NASA Astrophysics Data System (ADS)

    Christova, E.; Leader, E.; Stoilov, M.

    2018-03-01

    At present, the Boer-Mulders (BM) function for a given quark flavor is extracted from data on semi-inclusive deep inelastic scattering (SIDIS) using the simplifying assumption that it is proportional to the Sivers function for that flavor. In a recent paper, we suggested that the consistency of this assumption could be tested using information on so-called difference asymmetries i.e. the difference between the asymmetries in the production of particles and their antiparticles. In this paper, using the SIDIS COMPASS deuteron data on the ⟨cos ϕh⟩ , ⟨cos 2 ϕh⟩ and Sivers difference asymmetries, we carry out two independent consistency tests of the assumption of proportionality, but here applied to the sum of the valence-quark contributions. We find that such an assumption is compatible with the data. We also show that the proportionality assumptions made in the existing parametrizations of the BM functions are not compatible with our analysis, which suggests that the published results for the Boer-Mulders functions for individual flavors are unreliable. The ⟨cos ϕh⟩ and ⟨cos 2 ϕh⟩ asymmetries receive contributions also from the, in principle, calculable Cahn effect. We succeed in extracting the Cahn contributions from experiment (we believe for the first time) and compare with their calculated values, with interesting implications.

  7. Procedures to develop a computerized adaptive test to assess patient-reported physical functioning.

    PubMed

    McCabe, Erin; Gross, Douglas P; Bulut, Okan

    2018-06-07

    The purpose of this paper is to demonstrate the procedures to develop and implement a computerized adaptive patient-reported outcome (PRO) measure using secondary analysis of a dataset and items from fixed-format legacy measures. We conducted secondary analysis of a dataset of responses from 1429 persons with work-related lower extremity impairment. We calibrated three measures of physical functioning on the same metric, based on item response theory (IRT). We evaluated efficiency and measurement precision of various computerized adaptive test (CAT) designs using computer simulations. IRT and confirmatory factor analyses support combining the items from the three scales for a CAT item bank of 31 items. The item parameters for IRT were calculated using the generalized partial credit model. CAT simulations show that reducing the test length from the full 31 items to a maximum test length of 8 items, or 20 items is possible without a significant loss of information (95, 99% correlation with legacy measure scores). We demonstrated feasibility and efficiency of using CAT for PRO measurement of physical functioning. The procedures we outlined are straightforward, and can be applied to other PRO measures. Additionally, we have included all the information necessary to implement the CAT of physical functioning in the electronic supplementary material of this paper.

  8. [Lung function tests: the pneumologist and ambulatory care].

    PubMed

    Reis Ferreira, J M

    2004-01-01

    Lung function testing (LFT) has been standardized and greatly improved in the last three decades, but its relative complexity has driven to recent sistematization and standardization of its applicability in the office and in primary care. In memorian of Prof António Couto, and of his outstanding role in the promotion of LFT in Potyugal, this conference deals with the definition of office spirometry, its application range, and the essential steps for the performance, in acceptable quality and reproducibility conditioms. The role of the specialist in promoting this method, and his support to possible spirometry performers, is aimed as an important request in the success of the practical and used technique in family practice and primary health care.

  9. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    PubMed

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Validity of the Timed Up and Go Test as a Measure of Functional Mobility in Persons With Multiple Sclerosis.

    PubMed

    Sebastião, Emerson; Sandroff, Brian M; Learmonth, Yvonne C; Motl, Robert W

    2016-07-01

    To examine the validity of the timed Up and Go (TUG) test as a measure of functional mobility in persons with multiple sclerosis (MS) by using a comprehensive framework based on construct validity (ie, convergent and divergent validity). Cross-sectional study. Hospital setting. Community-residing persons with MS (N=47). Not applicable. Main outcome measures included the TUG test, timed 25-foot walk test, 6-minute walk test, Multiple Sclerosis Walking Scale-12, Late-Life Function and Disability Instrument, posturography evaluation, Activities-specific Balance Confidence scale, Symbol Digits Modalities Test, Expanded Disability Status Scale, and the number of steps taken per day. The TUG test was strongly associated with other valid outcome measures of ambulatory mobility (Spearman rank correlation, rs=.71-.90) and disability status (rs=.80), moderately to strongly associated with balance confidence (rs=.66), and weakly associated with postural control (ie, balance) (rs=.31). The TUG test was moderately associated with cognitive processing speed (rs=.59), but not associated with other nonambulatory measures (ie, Late-Life Function and Disability Instrument-upper extremity function). Our findings support the validity of the TUG test as a measure of functional mobility. This warrants its inclusion in patients' assessment alongside other valid measures of functional mobility in both clinical and research practice in persons with MS. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. [Combined pulmonary fibrosis and emphysema (CPFE)--limitation of usual lung function test and challenge at practice].

    PubMed

    Takai, Daiya

    2014-12-01

    Spirometry and the flow-volume curve test are commonly performed lung function tests. However, a unique clinical entity occasionally shows almost normal data in these tests, and is therefore missed on screening tests. The clinical entity of combined pulmonary emphysema and pulmdoary fibrosis was recognized and documented in the 90's in Japan, the USA, and Europe. Typical emphysema shows obstructive disorders, and pulmonary fibrosis shows restrictive disorders. Thus, the combination of both should lead to a combined disorder pattern in lung function tests, but this is not the case. In 2005, Cottin reported and redefined this combination of emphysema and fibrosis of the lung as "Combined Pulmonary Fibrosis and Emphysema" (CPFE). The patients are typically heavily smoking males who show an almost normal lung function. The upper lobe of these patients usually shows severe emphysema, which contributes to a static volume and a late phase in the forced volume test. On the other hand their lower lobe shows fibrotic change. The fibrotic portion contributes to early phase flow in the flow-volume curve. These mechanisms are a reason for the normal pattern appearance in lung function tests in CPFE patients. As a matter of course, these patients have damaged upper and lower lobes: their diffusing capacity of the lung shows a low performance, their saturation of blood hemoglobin decreases soon after light exercise, and their KL-6 (a blood marker of pulmonary fibrosis) usually shows a high value. They are considered a high risk group regarding complications of post-surgical treatment. Thus, when medical technologists identify suspicious cases, they should advise doctors to add diffusing capacity and KL-6 tests. (Review).

  12. Executive Functions as Endophenotypes in ADHD: Evidence from the Cambridge Neuropsychological Test Battery (CANTAB)

    ERIC Educational Resources Information Center

    Gau, Susan Shur-Fen; Shang, Chi-Yung

    2010-01-01

    Background: Little is known about executive functions among unaffected siblings of children with attention deficit/hyperactivity disorder (ADHD), and there is lack of such information from non-Western countries. We examined verbal and nonverbal executive functions in adolescents with ADHD, unaffected siblings and controls to test whether executive…

  13. Study of Abnormal Liver Function Test during Pregnancy in a Tertiary Care Hospital in Chhattisgarh.

    PubMed

    Mishra, Nalini; Mishra, V N; Thakur, Parineeta

    2016-10-01

    Abnormal liver function tests (LFTs) in pregnancy require proper interpretation in order to avoid pitfalls in the diagnosis. The underlying disorder can have a significant effect on the outcome of both mother and foetus. The present study was done with the objective to study the clinical profile, incidence and possible causes of derangements of liver function tests. Eighty pregnant women with abnormal liver dysfunction were studied prospectively. Women with chronic liver disease and drug-induced abnormal liver function test were excluded. All available LFTs including LDH were studied along with some more definitive tests to aid identification of underlying cause. Foetomaternal outcome was noted in all. The incidence of abnormal LFT was 0.9 %. 13/80 (16.75 %) women had liver disorder not specific to pregnancy, whereas 67/80 (83.25 %) women had pregnancy-specific liver dysfunction. Of these, 65(81.25 %) women with liver dysfunction had pre-eclampsia including 11 (13.75 %) with HELLP and six women with eclampsia. 48/65 (60 %) women had pre-eclampsia in the absence of HELLP syndrome or eclampsia. The mean value for bilirubin (mg %) in hypertensive disorders of pregnancy ranged from 1.64 to 3.8, between 5 and 10 for ICP and AFLP and >10 in infective hepatitis. Transaminases were highest in infective hepatitis, whereas alkaline phosphate was highest in ICP. Total 27 (33.75 %) women suffered from adverse outcome with four (5 %) maternal deaths and 23 (28.75 %) major maternal morbidities. 33/80 (41.25 %) women had intrauterine death. 26.25 % babies were small for date. Pregnancy-specific disorders are the leading cause of abnormal liver function test during pregnant state particularly in the third trimester. Pre-eclampsia-related disorder is the commonest. Gestational age of pregnancy and relative values of various liver function tests in different pregnancy-specific and pregnancy nonspecific disorders appear to be the best guide to clinch the diagnosis.

  14. Thyroid function testing in elephant seals in health and disease.

    PubMed

    Yochem, Pamela K; Gulland, Frances M D; Stewart, Brent S; Haulena, Martin; Mazet, Jonna A K; Boyce, Walter M

    2008-02-01

    Northern Elephant Seal Skin Disease (NESSD) is a severe, ulcerative, skin condition of unknown cause affecting primarily yearling northern elephant seals (Mirounga angustirostris); it has been associated with decreased levels of circulating thyroxine (T4) and triiodothyronine (T3). Abnormalities of the thyroid gland that result in decreased hormone levels (hypothyroidism) can result in hair loss, scaling and secondary skin infections. However, concurrent illness (including skin ailments) can suppress basal levels of thyroid hormones and mimic hypothyroidism; when this occurs in animals with normal thyroid glands it is called "sick euthyroid syndrome". The two conditions (true hypothyroidism vs. "sick euthyroid") can be distinguished in dogs by testing the response of the thyroid gland to exogenous thyrotropin (Thyroid Stimulating Hormone, TSH). To determine whether hypothyroidism is involved in the etiology of NESSD, we tested thyroid function of stranded yearling elephant seals in the following categories: healthy seals (rehabilitated and ready for release; N=9), seals suffering from NESSD (N=16) and seals with other illnesses (e.g., lungworm pneumonia; N=10). Levels of T4 increased significantly for all three categories of elephant seals following TSH stimulation, suggesting that seals with NESSD are "sick euthyroid" and that the disease is not associated with abnormal thyroid gland function.

  15. Estimation of Reliability Coefficients Using the Test Information Function and Its Modifications.

    ERIC Educational Resources Information Center

    Samejima, Fumiko

    1994-01-01

    The reliability coefficient is predicted from the test information function (TIF) or two modified TIF formulas and a specific trait distribution. Examples illustrate the variability of the reliability coefficient across different trait distributions, and results are compared with empirical reliability coefficients. (SLD)

  16. Emotional-volitional components of operator reliability. [sensorimotor function testing under stress

    NASA Technical Reports Server (NTRS)

    Mileryan, Y. A.

    1975-01-01

    Sensorimotor function testing in a tracking task under stressfull working conditions established a psychological characterization for a successful aviation pilot: Motivation significantly increased the reliability and effectiveness of their work. Their acitivities were aimed at suppressing weariness and the feeling of fear caused by the stress factors; they showed patience, endurance, persistence, and a capacity for lengthy volitional efforts.

  17. Formal Functional Test Designs: Bridging the Gap Between Test Requirements and Test Specifications

    NASA Technical Reports Server (NTRS)

    Hops, Jonathan

    1993-01-01

    This presentation describes the testing life cycle, the purpose of the test design phase, and test design methods and gives an example application. Also included is a description of Test Representation Language (TRL), a summary of the language, and an example of an application of TRL. A sample test requirement and sample test design are included.

  18. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    PubMed

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P < 0.05). FEV1/FVC and %NVQ had the highest correlation (r = 0.82). FEV1 was also best correlated with %NVQ (r = 0.64). DLCO was best correlated with the volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. Effectiveness of interventions to reduce ordering of thyroid function tests: a systematic review

    PubMed Central

    Abbott, Rebecca; Rogers, Morwenna; Fleming, Simon; Patterson, Anthea; Hamilton, William Trevor; Heaton, Janet; Vaidya, Bijay; Hyde, Christopher

    2016-01-01

    Objectives To evaluate the effectiveness of behaviour changing interventions targeting ordering of thyroid function tests. Design Systematic review. Data sources MEDLINE, EMBASE and the Cochrane Database up to May 2015. Eligibility criteria for selecting studies We included studies evaluating the effectiveness of behaviour change interventions aiming to reduce ordering of thyroid function tests. Randomised controlled trials (RCTs), non-randomised controlled studies and before and after studies were included. There were no language restrictions. Study appraisal and synthesis methods 2 reviewers independently screened all records identified by the electronic searches and reviewed the full text of any deemed potentially relevant. Study details were extracted from the included papers and their methodological quality assessed independently using a validated tool. Disagreements were resolved through discussion and arbitration by a third reviewer. Meta-analysis was not used. Results 27 studies (28 papers) were included. They evaluated a range of interventions including guidelines/protocols, changes to funding policy, education, decision aids, reminders and audit/feedback; often intervention types were combined. The most common outcome measured was the rate of test ordering, but the effect on appropriateness, test ordering patterns and cost were also measured. 4 studies were RCTs. The majority of the studies were of poor or moderate methodological quality. The interventions were variable and poorly reported. Only 4 studies reported unsuccessful interventions but there was no clear pattern to link effect and intervention type or other characteristics. Conclusions The results suggest that behaviour change interventions are effective particularly in reducing the volume of thyroid function tests. However, due to the poor methodological quality and reporting of the studies, the likely presence of publication bias and the questionable relevance of some interventions to current

  20. Random regression models using different functions to model test-day milk yield of Brazilian Holstein cows.

    PubMed

    Bignardi, A B; El Faro, L; Torres Júnior, R A A; Cardoso, V L; Machado, P F; Albuquerque, L G

    2011-10-31

    We analyzed 152,145 test-day records from 7317 first lactations of Holstein cows recorded from 1995 to 2003. Our objective was to model variations in test-day milk yield during the first lactation of Holstein cows by random regression model (RRM), using various functions in order to obtain adequate and parsimonious models for the estimation of genetic parameters. Test-day milk yields were grouped into weekly classes of days in milk, ranging from 1 to 44 weeks. The contemporary groups were defined as herd-test-day. The analyses were performed using a single-trait RRM, including the direct additive, permanent environmental and residual random effects. In addition, contemporary group and linear and quadratic effects of the age of cow at calving were included as fixed effects. The mean trend of milk yield was modeled with a fourth-order orthogonal Legendre polynomial. The additive genetic and permanent environmental covariance functions were estimated by random regression on two parametric functions, Ali and Schaeffer and Wilmink, and on B-spline functions of days in milk. The covariance components and the genetic parameters were estimated by the restricted maximum likelihood method. Results from RRM parametric and B-spline functions were compared to RRM on Legendre polynomials and with a multi-trait analysis, using the same data set. Heritability estimates presented similar trends during mid-lactation (13 to 31 weeks) and between week 37 and the end of lactation, for all RRM. Heritabilities obtained by multi-trait analysis were of a lower magnitude than those estimated by RRM. The RRMs with a higher number of parameters were more useful to describe the genetic variation of test-day milk yield throughout the lactation. RRM using B-spline and Legendre polynomials as base functions appears to be the most adequate to describe the covariance structure of the data.

  1. Functional toxicology: tools to advance the future of toxicity testing

    PubMed Central

    Gaytán, Brandon D.; Vulpe, Chris D.

    2014-01-01

    The increased presence of chemical contaminants in the environment is an undeniable concern to human health and ecosystems. Historically, by relying heavily upon costly and laborious animal-based toxicity assays, the field of toxicology has often neglected examinations of the cellular and molecular mechanisms of toxicity for the majority of compounds—information that, if available, would strengthen risk assessment analyses. Functional toxicology, where cells or organisms with gene deletions or depleted proteins are used to assess genetic requirements for chemical tolerance, can advance the field of toxicity testing by contributing data regarding chemical mechanisms of toxicity. Functional toxicology can be accomplished using available genetic tools in yeasts, other fungi and bacteria, and eukaryotes of increased complexity, including zebrafish, fruit flies, rodents, and human cell lines. Underscored is the value of using less complex systems such as yeasts to direct further studies in more complex systems such as human cell lines. Functional techniques can yield (1) novel insights into chemical toxicity; (2) pathways and mechanisms deserving of further study; and (3) candidate human toxicant susceptibility or resistance genes. PMID:24847352

  2. Astronaut Owen Garriott - Test Subject - Human Vestibular Function Experiment

    NASA Image and Video Library

    1973-08-09

    S73-34171 (9 Aug. 1973) --- Scientist-astronaut Owen K. Garriott, Skylab 3 science pilot, serves as test subject for the Skylab ?Human Vestibular Function? M131 Experiment, as seen in this photographic reproduction taken from a television transmission made by a color TV camera aboard the Skylab space station in Earth orbit. The objectives of the Skylab M131 experiment are to obtain data pertinent to establishing the validity of measurements of specific behavioral/physiological responses influenced by vestibular activity under one-g and zero-g conditions; to determine man?s adaptability to unusual vestibular conditions and predict habitability of future spacecraft conditions involving reduced gravity and Coriollis forces; and to measure the accuracy and variability in man?s judgment of spatial coordinates based on atypical gravity receptor cues and inadequate visual cures. Dr. Garriott is seated in the experiment?s litter chair which can rotate the test subject at predetermined rotational velocity or programmed acceleration/decelerational profile. Photo credit: NASA

  3. Design and testing of a functional arm orthosis in patients with neuromuscular diseases.

    PubMed

    Rahman, Tariq; Sample, Whitney; Seliktar, Rahamim; Scavina, Mena T; Clark, Alisa L; Moran, Kacy; Alexander, Michael A

    2007-06-01

    The objective of this study was to determine the utility of a passive gravity-balanced arm orthosis, the Wilmington robotic exoskeleton (WREX), for patients with neuromuscular diseases. The WREX, a four-degrees-of-freedom functional orthosis, is energized by rubber bands to eliminate gravity and is attached to the wheelchair. The development and clinical testing of WREX is described in this report. Seventeen patients (14 boys and 3 girls) with muscular disabilities participated in the study. Ages ranged from 4 to 20 years. Criteria for inclusion included a weakened arm, use of a wheelchair, the ability to grasp and release objects, and the ability to provide feedback on device use. Testing consisted of administering the Jebsen test of hand function without WREX and then testing again after approximately two weeks of wearing the WREX orthosis. The timed results of each task within the test then were compared. Specific tasks related to vertical movement required less time to perform with the WREX. A large number of subjects were able to perform the Jebsen tasks with the WREX, where they were unable to perform the task without the WREX. Patients can benefit from WREX because it increases their performance in daily living activities and makes many tasks possible. The range-of-motion in the patients' arms increased considerably, while the time required to complete some of the Jebsen test tasks decreased. Most patients were very receptive to WREX, although a few were ambivalent.

  4. A virtual shopping test for realistic assessment of cognitive function

    PubMed Central

    2013-01-01

    Background Cognitive dysfunction caused by brain injury often prevents a patient from achieving a healthy and high quality of life. By now, each cognitive function is assessed precisely by neuropsychological tests. However, it is also important to provide an overall assessment of the patients’ ability in their everyday life. We have developed a Virtual Shopping Test (VST) using virtual reality technology. The objective of this study was to clarify 1) the significance of VST by comparing VST with other conventional tests, 2) the applicability of VST to brain-damaged patients, and 3) the performance of VST in relation to age differences. Methods The participants included 10 patients with brain damage, 10 age-matched healthy subjects for controls, 10 old healthy subjects, and 10 young healthy subjects. VST and neuropsychological tests/questionnaires about attention, memory and executive function were conducted on the patients, while VST and the Mini-Mental State Examination (MMSE) were conducted on the controls and healthy subjects. Within the VST, the participants were asked to buy four items in the virtual shopping mall quickly in a rational way. The score for evaluation included the number of items bought correctly, the number of times to refer to hints, the number of movements between shops, and the total time spent to complete the shopping. Results Some variables on VST correlated with the scores of conventional assessment about attention and everyday memory. The mean number of times referring to hints and the mean number of movements were significantly larger for the patients with brain damage, and the mean total time was significantly longer for the patients than for the controls. In addition, the mean total time was significantly longer for the old than for the young. Conclusions The results suggest that VST is able to evaluate the ability of attention and everyday memory in patients with brain damage. The time of VST is increased by age. PMID:23777412

  5. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests.

    PubMed

    Rijken, Noortje H; van Engelen, Baziel G; Weerdesteyn, Vivian; Geurts, Alexander C

    2015-12-01

    To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). Case-control study. University medical center. Patients with various severity levels of FSHD (n=9) and healthy control subjects (n=10) were included (N=19). Not applicable. A 4-point ordinal scale was designed to grade performance on the following 4 antigravity tests: sit to stance, stance to sit, step up, and step down. In addition, the 6-minute walk test, 10-m walking test, Berg Balance Scale, and timed Up and Go test were administered as conventional tests. Construct validity was determined by linear regression analysis using the Clinical Severity Score (CSS) as the dependent variable. Interrater agreement was tested using a κ analysis. Patients with FSHD performed worse on all 4 antigravity tests compared with the controls. Stronger correlations were found within than between test categories (antigravity vs conventional). The antigravity tests revealed the highest explained variance with regard to the CSS (R(2)=.86, P=.014). Interrater agreement was generally good. The results of this exploratory study support the construct validity and interrater reliability of the proposed antigravity tests for the assessment of functional capacity in patients with FSHD taking into account the use of compensatory strategies. Future research should further validate these results in a larger sample of patients with FSHD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. Pulmonary function test in formalin exposed and nonexposed subjects: A comparative study

    PubMed Central

    Uthiravelu, P.; Saravanan, A.; Kumar, C. Kishor; Vaithiyanandane, V.

    2015-01-01

    Background: The main function of the lung is gas exchange, which can be assessed in several ways. A spirometer measures the flow and the volumes of the inspired and expired air. The thoracic and abdominal muscle strength plays an important role in pulmonary function and diffusing lung capacity. Aims and Objectives: The aim of this study was to assess the effects of formalin exposure on the pulmonary function to compare with healthy individuals. To assess the chronic effects of formalin exposure on Pulmonary function tests (PFTs) in the faculties, lab technicians and attender of the Department of Anatomy and Pathology of SRM Medical Hospital and Research Centre, Kattankulathur. Materials and Methods: This prospective study was carried out in 50 healthy formalin exposed subjects (at least 5 years exposure) from Department of Anatomy and Pathology of SRM Medical College Hospital and Research Centre, Kattankulathur and 50 healthy controls of same age group of this study were included after obtaining ethical clearance and consent ‘Easy One Pro Spirometer (Ndd Medical Technologies, Cheshire SK 101LT, United Kingdom) was used to find out the PFT. Results: Student's t-test was applied to compare the PFT parameters between formalin exposed and formalin nonexposed group. There was a significant difference in mean and standard deviation of pulmonary parameters with the P < 0.005 in formalin exposed, which shows that they have lesser ventilatory drive. Conclusion: The formalin exposed subjects in our study presented with a mixed disorder of both obstructive and restrictive type. We also found that there was a negative correlation of pulmonary function with that of the degree and duration of exposure to formalin. PMID:26015743

  7. 75 FR 29962 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... SF50 airplanes. 1. Function and Reliability Testing Flight tests: In place of 14 CFR part 21.35(b)(2... Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed special..., 1951, and deleted the service test requirements in Section 3.19 for airplanes of 6,000 pounds maximum...

  8. Physiotherapist agreement when visually rating movement quality during lower extremity functional screening tests.

    PubMed

    Whatman, Chris; Hing, Wayne; Hume, Patria

    2012-05-01

    To investigate physiotherapist agreement in rating movement quality during lower extremity functional tests using two visual rating methods and physiotherapists with differing clinical experience. Clinical measurement. Six healthy individuals were rated by 44 physiotherapists. These raters were in three groups (inexperienced, novice, experienced). Video recordings of all six individuals performing four lower extremity functional tests were visually rated (dichotomous or ordinal scale) using two rating methods (overall or segment) on two occasions separated by 3-4 weeks. Intra and inter-rater agreement for physiotherapists was determined using overall percentage agreement (OPA) and the first order agreement coefficient (AC1). Intra-rater agreement for overall and segment methods ranged from slight to almost perfect (OPA: 29-96%, AC1: 0.01 to 0.96). AC1 agreement was better in the experienced group (84-99% likelihood) and for dichotomous rating (97-100% likelihood). Inter-rater agreement ranged from fair to good (OPA: 45-79%; AC1: 0.22-0.71). AC1 agreement was not influenced by clinical experience but was again better using dichotomous rating. Physiotherapists' visual rating of movement quality during lower extremity functional tests resulted in slight to almost perfect intra-rater agreement and fair to good inter-rater agreement. Agreement improved with increased level of clinical experience and use of dichotomous rating. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Using functional theory to promote HIV testing: the impact of value-expressive messages, uncertainty, and fear.

    PubMed

    Hullett, Craig R

    2006-01-01

    This study tests the utility of the functional theory of attitudes and arousal of fear in motivating college students to get tested for HIV. It is argued from the perspective of functional theory that value-expressive appeals to get tested for the purpose of taking care of one's own health could be effective if that goal is desired by message targets who are sexually active and unaware of their sexually transmitted disease status. As part of the process, the effectiveness of these appeals is increased by the arousal of uncertainty and fear. A model detailing the mediating processes is proposed and found to be consistent with the data. Overall, messages advocating testing for the self-interested reason of one's own health were more effective than messages advocating testing for the goal of protecting one's partners.

  10. Mixed-meal tolerance test versus glucagon stimulation test for the assessment of beta-cell function in therapeutic trials in type 1 diabetes.

    PubMed

    Greenbaum, Carla J; Mandrup-Poulsen, Thomas; McGee, Paula Friedenberg; Battelino, Tadej; Haastert, Burkhard; Ludvigsson, Johnny; Pozzilli, Paolo; Lachin, John M; Kolb, Hubert

    2008-10-01

    Beta-cell function in type 1 diabetes clinical trials is commonly measured by C-peptide response to a secretagogue in either a mixed-meal tolerance test (MMTT) or a glucagon stimulation test (GST). The Type 1 Diabetes TrialNet Research Group and the European C-peptide Trial (ECPT) Study Group conducted parallel randomized studies to compare the sensitivity, reproducibility, and tolerability of these procedures. In randomized sequences, 148 TrialNet subjects completed 549 tests with up to 2 MMTT and 2 GST tests on separate days, and 118 ECPT subjects completed 348 tests (up to 3 each) with either two MMTTs or two GSTs. Among individuals with up to 4 years' duration of type 1 diabetes, >85% had measurable stimulated C-peptide values. The MMTT stimulus produced significantly higher concentrations of C-peptide than the GST. Whereas both tests were highly reproducible, the MMTT was significantly more so (R(2) = 0.96 for peak C-peptide response). Overall, the majority of subjects preferred the MMTT, and there were few adverse events. Some older subjects preferred the shorter duration of the GST. Nausea was reported in the majority of GST studies, particularly in the young age-group. The MMTT is preferred for the assessment of beta-cell function in therapeutic trials in type 1 diabetes.

  11. Hypothesis testing in functional linear regression models with Neyman's truncation and wavelet thresholding for longitudinal data.

    PubMed

    Yang, Xiaowei; Nie, Kun

    2008-03-15

    Longitudinal data sets in biomedical research often consist of large numbers of repeated measures. In many cases, the trajectories do not look globally linear or polynomial, making it difficult to summarize the data or test hypotheses using standard longitudinal data analysis based on various linear models. An alternative approach is to apply the approaches of functional data analysis, which directly target the continuous nonlinear curves underlying discretely sampled repeated measures. For the purposes of data exploration, many functional data analysis strategies have been developed based on various schemes of smoothing, but fewer options are available for making causal inferences regarding predictor-outcome relationships, a common task seen in hypothesis-driven medical studies. To compare groups of curves, two testing strategies with good power have been proposed for high-dimensional analysis of variance: the Fourier-based adaptive Neyman test and the wavelet-based thresholding test. Using a smoking cessation clinical trial data set, this paper demonstrates how to extend the strategies for hypothesis testing into the framework of functional linear regression models (FLRMs) with continuous functional responses and categorical or continuous scalar predictors. The analysis procedure consists of three steps: first, apply the Fourier or wavelet transform to the original repeated measures; then fit a multivariate linear model in the transformed domain; and finally, test the regression coefficients using either adaptive Neyman or thresholding statistics. Since a FLRM can be viewed as a natural extension of the traditional multiple linear regression model, the development of this model and computational tools should enhance the capacity of medical statistics for longitudinal data.

  12. Effects of Peripheral Vestibular Dysfunction on Dynamic Postural Stability Measured by the Functional Reach Test and Timed Up and Go Test.

    PubMed

    Nishi, Toshiko; Kamogashira, Teru; Fujimoto, Chisato; Kinoshita, Makoto; Egami, Naoya; Sugasawa, Keiko; Yamasoba, Tatsuya; Iwasaki, Shinichi

    2017-06-01

    To investigate the influence of vestibular function on dynamic postural stability assessed by the functional reach test (FRT) and the timed up and go test (TUG). Retrospective study. Tertiary referral center. The FRT and TUG were performed in 399 patients with dizziness. The effects of peripheral vestibular dysfunction assessed by the caloric test and cervical vestibular evoked myogenic potentials (cVEMPs) to air-conducted sound (500 Hz, tone burst) on the results of FRT and TUG were analyzed. Neither FRT nor TUG scores showed significant differences in relation to the results of the caloric test ( P > .3). The FRT scores in patients who showed abnormal cVEMP responses on both sides were significantly smaller than those in patients who showed normal cVEMP responses ( P < .01). The TUG scores in patients who showed abnormal cVEMP responses on both sides were significantly greater than those in patients who showed normal cVEMP responses ( P < .05). The vestibulo-spinal reflex mediated by the saccule and its afferents is one of the factors that influence the maintenance of dynamic postural stability as measured by FRT and TUG.

  13. Functional test measures as risk indicators for low back pain among fixed-wing military pilots.

    PubMed

    Honkanen, Tuomas; Kyröläinen, H; Avela, J; Mäntysaari, M

    2017-02-01

    The purpose of this study was to find out the risk value of functional fitness test (FFT) results for low back pain (LBP) among fixed-wing military pilots. A total of 104 male military pilots were recruited for this study. The study was conducted with a self-administered questionnaire and FFT. The functional tests were performed in the beginning of study (baseline). The questionnaire was carried out at the baseline and 5 years later. The isometric low back endurance test result was associated with physical activity-related LBP experienced 5 years later. Demographic information was not associated with LBP. The prevalence of overall LBP was 71% and the flight-related LBP prevalence was 31% at the baseline. Our findings show that LBP among military pilots is a common problem but it is also associated with tasks other than flying. The functional test results were not associated with flight-related LBP but adequate isometric back endurance may have protective role in LBP caused in physical activities. When trying to find the pilots with increased risk of flight-related LBP, a more sensitive set of tests should be considered. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Integrative Examination of Motor Abilities in Dialysis Patients and Selection of Tests for a Standardized Physical Function Assessment.

    PubMed

    Bučar Pajek, Maja; Leskošek, Bojan; Vivoda, Tjaša; Svilan, Katarina; Čuk, Ivan; Pajek, Jernej

    2016-06-01

    To reduce the need for a large number of executed physical function tests we examined inter-relations and determined predictive power for daily physical activity of the following tests: 6-min walk, 10 repetition sit-to-stand, time up-and-go, Storke balance, handgrip strength, upper limb tapping and sitting forward bend tests. In 90 dialysis and 140 healthy control subjects we found high correlations between all tests, especially those engaging lower extremities. Sit-to-stand, forward bend and handgrip strength were selected for the test battery and composite motor performance score. Sit-to-stand test was superior in terms of sensitivity to uremia effects and association with daily physical function in adjusted analyses. There was no incremental value in calculating the composite performance score. We propose to standardize the physical function assessment of dialysis patients for cross-sectional and longitudinal observations with three simple, cheap, well-accessible and easily performed test tools: sit-to-stand test, handgrip strength and Human Activity Profile questionnaire. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  15. 49 CFR 40.127 - What are the MRO's functions in reviewing negative test results?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What are the MRO's functions in reviewing negative test results? 40.127 Section 40.127 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification Process § 40.127 What are the MRO's...

  16. [Effects of education and strength training on functional tests among older people with osteoarthritis].

    PubMed

    Jiménez S, Christian Edgardo; Fernández G, Rubén; Zurita O, Félix; Linares G, Daniel; Farías M, Ariel

    2014-04-01

    Hip and knee osteoarthritis are important causes of pain and disability among older people. Education and strength training can alleviate symptoms and avoid functional deterioration. To assess muscle strength, fall risk and quality of life of older people with osteoarthritis and the effects of physiotherapy education and strength training on these variables. Thirty participants aged 78 ± 5 years (63% women) were randomly assigned to receive physiotherapy (Controls), physiotherapy plus education (Group 1) and physiotherapy plus strength training (group 2). At baseline and after 16 weeks of intervention, patients were evaluated with the Senior Fitness Test, Timed Up and Go and Quality of Life score short form (SF-36). During the intervention period, Senior Fitness Test and Timed Up and Go scores improved in all groups and SF-36 did not change. The improvement in Senior Fitness Test and Timed Up and Go was more marked in Groups 1 and 2 than in the control group. Education and strength training improve functional tests among older people with osteoarthritis.

  17. Preoperative prediction of inpatient recovery of function after total hip arthroplasty using performance-based tests: a prospective cohort study.

    PubMed

    Oosting, Ellen; Hoogeboom, Thomas J; Appelman-de Vries, Suzan A; Swets, Adam; Dronkers, Jaap J; van Meeteren, Nico L U

    2016-01-01

    The aim of this study was to evaluate the value of conventional factors, the Risk Assessment and Predictor Tool (RAPT) and performance-based functional tests as predictors of delayed recovery after total hip arthroplasty (THA). A prospective cohort study in a regional hospital in the Netherlands with 315 patients was attending for THA in 2012. The dependent variable recovery of function was assessed with the Modified Iowa Levels of Assistance scale. Delayed recovery was defined as taking more than 3 days to walk independently. Independent variables were age, sex, BMI, Charnley score, RAPT score and scores for four performance-based tests [2-minute walk test, timed up and go test (TUG), 10-meter walking test (10 mW) and hand grip strength]. Regression analysis with all variables identified older age (>70 years), Charnley score C, slow walking speed (10 mW >10.0 s) and poor functional mobility (TUG >10.5 s) as the best predictors of delayed recovery of function. This model (AUC 0.85, 95% CI 0.79-0.91) performed better than a model with conventional factors and RAPT scores, and significantly better (p = 0.04) than a model with only conventional factors (AUC 0.81, 95% CI 0.74-0.87). The combination of performance-based tests and conventional factors predicted inpatient functional recovery after THA. Two simple functional performance-based tests have a significant added value to a more conventional screening with age and comorbidities to predict recovery of functioning immediately after total hip surgery. Patients over 70 years old, with comorbidities, with a TUG score >10.5 s and a walking speed >1.0 m/s are at risk for delayed recovery of functioning. Those high risk patients need an accurate discharge plan and could benefit from targeted pre- and postoperative therapeutic exercise programs.

  18. Genetic Influences on Cognitive Function Using the Cambridge Neuropsychological Test Automated Battery

    ERIC Educational Resources Information Center

    Singer, Jamie J.; MacGregor, Alex J.; Cherkas, Lynn F.; Spector, Tim D.

    2006-01-01

    The genetic relationship between intelligence and components of cognition remains controversial. Conflicting results may be a function of the limited number of methods used in experimental evaluation. The current study is the first to use CANTAB (The Cambridge Neuropsychological Test Automated Battery). This is a battery of validated computerised…

  19. Using speech sounds to test functional spectral resolution in listeners with cochlear implants

    PubMed Central

    Winn, Matthew B.; Litovsky, Ruth Y.

    2015-01-01

    In this study, spectral properties of speech sounds were used to test functional spectral resolution in people who use cochlear implants (CIs). Specifically, perception of the /ba/-/da/ contrast was tested using two spectral cues: Formant transitions (a fine-resolution cue) and spectral tilt (a coarse-resolution cue). Higher weighting of the formant cues was used as an index of better spectral cue perception. Participants included 19 CI listeners and 10 listeners with normal hearing (NH), for whom spectral resolution was explicitly controlled using a noise vocoder with variable carrier filter widths to simulate electrical current spread. Perceptual weighting of the two cues was modeled with mixed-effects logistic regression, and was found to systematically vary with spectral resolution. The use of formant cues was greatest for NH listeners for unprocessed speech, and declined in the two vocoded conditions. Compared to NH listeners, CI listeners relied less on formant transitions, and more on spectral tilt. Cue-weighting results showed moderately good correspondence with word recognition scores. The current approach to testing functional spectral resolution uses auditory cues that are known to be important for speech categorization, and can thus potentially serve as the basis upon which CI processing strategies and innovations are tested. PMID:25786954

  20. Relationships of Functional Tests Following ACL Reconstruction: Exploratory Factor Analyses of the Lower Extremity Assessment Protocol.

    PubMed

    DiFabio, Melissa; Slater, Lindsay V; Norte, Grant; Goetschius, John; Hart, Joseph M; Hertel, Jay

    2018-03-01

    After ACL reconstruction (ACLR), deficits are often assessed using a variety of functional tests, which can be time consuming. It is unknown whether these tests provide redundant or unique information. To explore relationships between components of a battery of functional tests, the Lower Extremity Assessment Protocol (LEAP) was created to aid in developing the most informative, concise battery of tests for evaluating ACLR patients. Descriptive, cross-sectional. Laboratory. 76 ACLR patients (6.86±3.07 months postoperative) and 54 healthy participants. Isokinetic knee flexion and extension at 90 and 180 degrees/second, maximal voluntary isometric contraction for knee extension and flexion, single leg balance, 4 hopping tasks (single, triple, crossover, and 6-meter timed hop), and a bilateral drop vertical jump that was scored with the Landing Error Scoring System (LESS). Peak torque, average torque, average power, total work, fatigue indices, center of pressure area and velocity, hop distance and time, and LESS score. A series of factor analyses were conducted to assess grouping of functional tests on the LEAP for each limb in the ACLR and healthy groups and limb symmetry indices (LSI) for both groups. Correlations were run between measures that loaded on retained factors. Isokinetic and isometric strength tests for knee flexion and extension, hopping, balance, and fatigue index were identified as unique factors for all limbs. The LESS score loaded with various factors across the different limbs. The healthy group LSI analysis produced more factors than the ACLR LSI analysis. Individual measures within each factor had moderate to strong correlations. Isokinetic and isometric strength, hopping, balance, and fatigue index provided unique information. Within each category of measures, not all tests may need to be included for a comprehensive functional assessment of ACLR patients due to the high amount of shared variance between them.

  1. Quantitative electroencephalographic and neuropsychological investigation of an alternative measure of frontal lobe executive functions: the Figure Trail Making Test.

    PubMed

    Foster, Paul S; Drago, Valeria; Ferguson, Brad J; Harrison, Patti Kelly; Harrison, David W

    2015-12-01

    The most frequently used measures of executive functioning are either sensitive to left frontal lobe functioning or bilateral frontal functioning. Relatively little is known about right frontal lobe contributions to executive functioning given the paucity of measures sensitive to right frontal functioning. The present investigation reports the development and initial validation of a new measure designed to be sensitive to right frontal lobe functioning, the Figure Trail Making Test (FTMT). The FTMT, the classic Trial Making Test, and the Ruff Figural Fluency Test (RFFT) were administered to 42 right-handed men. The results indicated a significant relationship between the FTMT and both the TMT and the RFFT. Performance on the FTMT was also related to high beta EEG over the right frontal lobe. Thus, the FTMT appears to be an equivalent measure of executive functioning that may be sensitive to right frontal lobe functioning. Applications for use in frontotemporal dementia, Alzheimer's disease, and other patient populations are discussed.

  2. Comparison of muscle/lean mass measurement methods: correlation with functional and biochemical testing.

    PubMed

    Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N

    2018-03-01

    DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p < 0.0001) from one another with DXA total body less head being highest at 37.8 (7.3) kg, D3-C muscle mass at 21.1 (4.6) kg, and BIS total body intracellular water at 17.4 (3.5) kg. All mass assessment methods correlated with grip strength and jump power (R = 0.35-0.63, p < 0.0002), but not with gait speed or repeat chair rise. Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with

  3. Clamp-crushing vs. radiofrequency-assisted liver resection:changes in liver function tests.

    PubMed

    Palibrk, Ivan; Milicic, Biljana; Stojiljkovic, Ljuba; Manojlovic, Nebojsa; Dugalic, Vladimir; Bumbasirevic, Vesna; Kalezic, Nevena; Zuvela, Marinko; Milicevic, Miroslav

    2012-05-01

    Liver resection is the gold standard in managing patients with metastatic or primary liver cancer. The aim of our study was to compare the traditional clamp-crushing technique to the radiofrequency- assisted liver resection technique in terms of postoperative liver function. Liver function was evaluated preoperatively and on postoperative days 3 and 7. Liver synthetic function parameters (serum albumin level, prothrombin time and international normalized ratio), markers of hepatic injury and necrosis (serum alanine aminotransferase, aspartate aminotransferase and total bilirubin level) and microsomal activity (quantitative lidocaine test) were compared. Forty three patients completed the study (14 had clamp-crushing and 29 had radiofrequency assisted liver resection). The groups did not differ in demographic characteristics, pre-operative liver function, operative time and perioperative transfusion rate. In postoperative period, there were similar changes in monitored parameters in both groups except albumin levels, that were higher in radiofrequency-assisted liver resection group (p=0.047). Both, traditional clamp-crushing technique and radiofrequency assisted liver resection technique, result in similar postoperative changes of most monitored liver function parameters.

  4. Evaluation of Five Tests for Sensitivity to Functional Deficits following Cervical or Thoracic Dorsal Column Transection in the Rat

    PubMed Central

    Eggers, Ruben; Tuinenbreijer, Lizz; Kouwenhoven, Dorette; Verhaagen, Joost; Mason, Matthew R. J.

    2016-01-01

    The dorsal column lesion model of spinal cord injury targets sensory fibres which originate from the dorsal root ganglia and ascend in the dorsal funiculus. It has the advantages that fibres can be specifically traced from the sciatic nerve, verifiably complete lesions can be performed of the labelled fibres, and it can be used to study sprouting in the central nervous system from the conditioning lesion effect. However, functional deficits from this type of lesion are mild, making assessment of experimental treatment-induced functional recovery difficult. Here, five functional tests were compared for their sensitivity to functional deficits, and hence their suitability to reliably measure recovery of function after dorsal column injury. We assessed the tape removal test, the rope crossing test, CatWalk gait analysis, and the horizontal ladder, and introduce a new test, the inclined rolling ladder. Animals with dorsal column injuries at C4 or T7 level were compared to sham-operated animals for a duration of eight weeks. As well as comparing groups at individual timepoints we also compared the longitudinal data over the whole time course with linear mixed models (LMMs), and for tests where steps are scored as success/error, using generalized LMMs for binomial data. Although, generally, function recovered to sham levels within 2–6 weeks, in most tests we were able to detect significant deficits with whole time-course comparisons. On the horizontal ladder deficits were detected until 5–6 weeks. With the new inclined rolling ladder functional deficits were somewhat more consistent over the testing period and appeared to last for 6–7 weeks. Of the CatWalk parameters base of support was sensitive to cervical and thoracic lesions while hind-paw print-width was affected by cervical lesion only. The inclined rolling ladder test in combination with the horizontal ladder and the CatWalk may prove useful to monitor functional recovery after experimental treatment in this

  5. Investigation of the effects of mirror therapy on the upper extremity functions of stroke patients using the manual function test.

    PubMed

    Kim, Hwanhee; Shim, Jemyung

    2015-01-01

    [Purpose] The purpose of this study was to investigate the effects of mirror therapy on the upper extremity functions of stroke patients. [Subjects] The subjects of this study were 14 hemiplegia patients (8 males, 6 females; 9 infarction, 5 hemorrhage; 8 right hemiplegia, 6 left hemiplegia) who voluntarily consented to participate in the study. [Methods] The Korean version of the manual function test (MFT) was used in this study. The test was performed in the following order: arm movement (4 items), grasp and pinch (2 items), and manipulation (2 items). The experiment was conducted with the subjects sitting in a chair. The mirror was vertically placed in the sagittal plane on the desk. The paretic hand was placed behind the mirror, and the non-paretic hand was placed in front of the mirror so that it was reflected in the mirror. In this position, the subjects completed activities repetitively according to the mirror therapy program over the course of four weeks. [Results] There were significant increases in the grasp-and-pinch score and manipulation score. [Conclusion] In conclusion, the grasp-and-pinch and manipulation functions were improved through mirror therapy.

  6. Nuclear Technology. Course 30: Mechanical Inspection. Module 30-2, Pump Functional Testing.

    ERIC Educational Resources Information Center

    Wasel, Ed; Espy, John

    This second in a series of eight modules for a course titled Mechanical Inspection describes typical pump functional tests which are performed after pump installation and prior to release of the plant for unrestricted power operation. The module follows a typical format that includes the following sections: (1) introduction, (2) module…

  7. Testing for Nonuniform Differential Item Functioning with Multiple Indicator Multiple Cause Models

    ERIC Educational Resources Information Center

    Woods, Carol M.; Grimm, Kevin J.

    2011-01-01

    In extant literature, multiple indicator multiple cause (MIMIC) models have been presented for identifying items that display uniform differential item functioning (DIF) only, not nonuniform DIF. This article addresses, for apparently the first time, the use of MIMIC models for testing both uniform and nonuniform DIF with categorical indicators. A…

  8. Mixed-Meal Tolerance Test Versus Glucagon Stimulation Test for the Assessment of β-Cell Function in Therapeutic Trials in Type 1 Diabetes

    PubMed Central

    Greenbaum, Carla J.; Mandrup-Poulsen, Thomas; McGee, Paula Friedenberg; Battelino, Tadej; Haastert, Burkhard; Ludvigsson, Johnny; Pozzilli, Paolo; Lachin, John M.; Kolb, Hubert

    2008-01-01

    OBJECTIVE—β-Cell function in type 1 diabetes clinical trials is commonly measured by C-peptide response to a secretagogue in either a mixed-meal tolerance test (MMTT) or a glucagon stimulation test (GST). The Type 1 Diabetes TrialNet Research Group and the European C-peptide Trial (ECPT) Study Group conducted parallel randomized studies to compare the sensitivity, reproducibility, and tolerability of these procedures. RESEARCH DESIGN AND METHODS—In randomized sequences, 148 TrialNet subjects completed 549 tests with up to 2 MMTT and 2 GST tests on separate days, and 118 ECPT subjects completed 348 tests (up to 3 each) with either two MMTTs or two GSTs. RESULTS—Among individuals with up to 4 years’ duration of type 1 diabetes, >85% had measurable stimulated C-peptide values. The MMTT stimulus produced significantly higher concentrations of C-peptide than the GST. Whereas both tests were highly reproducible, the MMTT was significantly more so (R2 = 0.96 for peak C-peptide response). Overall, the majority of subjects preferred the MMTT, and there were few adverse events. Some older subjects preferred the shorter duration of the GST. Nausea was reported in the majority of GST studies, particularly in the young age-group. CONCLUSIONS—The MMTT is preferred for the assessment of β-cell function in therapeutic trials in type 1 diabetes. PMID:18628574

  9. The effect of diltiazem on the manifestations of hyperthyroidism and thyroid function tests.

    PubMed

    Keleştimur, F; Aksu, A

    1996-01-01

    The aim of this study is to evaluate the effect of diltiazem on the symptoms and signs of hyperthyroidism and thyroid function tests and to assess whether diltiazem can be used associated with an anti-thyroid drug, propylthiouracil. Twenty-two patients with hyperthyroidism were included in a prospective, randomized and placebo controlled study. Group 1 (n:12) patients received diltiazem, 60 mg twice a day, for 30 days. Group 2 (n:10) patients received placebo for 30 days. The patients in both groups were given propylthiouracil, 100 mg three times a day, for the last 20 days of the study period. The patients remained in the hospital during the first 10 days. A standardized hyperthyroid symptom score (HSS) and thyroid function tests including thyroid-stimulating hormone (TSH), free thyroxine (free T4), free triiodothyronine (free T3), total thyroxine (T4) and total triiodothyronine (T3) were evaluated before and after 10 and 30 days of the study period. HSS decreased from 27.80 +/- 4.54 to 22.51 +/- 4.04 after 10 days of diltiazem therapy in Group 1 (p < 0.01). But there was no change in HSS in Group 2 (p > 0.01). No significant changes in thyroid function tests have occurred in both groups after 10 days of treatment. Diltiazem can be used in patients with hyperthyroidism to alleviate adrenergic manifestations. It can also be safely combined with propylthiouracil.

  10. Testing functional trait-based mechanisms underpinning plant responses to grazing and linkages to ecosystem functioning in grasslands

    NASA Astrophysics Data System (ADS)

    Zheng, S. X.; Li, W. H.; Lan, Z. C.; Ren, H. Y.; Wang, K. B.; Bai, Y. F.

    2014-09-01

    Abundant evidence has shown that grazing alters plant functional traits, ecological strategies, community structure, and ecosystem functioning of grasslands. Few studies, however, have examined how plant responses to grazing are mediated by resource availability and functional group identity. We test functional trait-based mechanisms underlying the responses of different life forms to grazing and linkages to ecosystem functioning along a soil moisture gradient in the Inner Mongolia grassland. A principal component analysis (PCA) based on 9 traits × 276 species matrix showed that the plant size spectrum (i.e., individual biomass), leaf economics spectrum (leaf N content and leaf density), and light competition spectrum (height and stem-leaf biomass ratio) distinguished plant species responses to grazing. The three life forms exhibited differential strategies as indicated by trait responses to grazing. The annuals and biennials adopted grazing-tolerant strategies associated with high growth rate, reflected by high leaf N content and specific leaf area. The perennial grasses exhibited grazing-tolerant strategies associated with great regrowth capacity and high palatability scores, whereas perennial forbs showed grazing-avoidant strategies with short stature and low palatability scores. In addition, the dominant perennial bunchgrasses exhibited mixed tolerance-resistance strategies to grazing and mixed acquisitive-conservative strategies in resource utilization. Grazing increased the relative abundance of perennial forbs with low palatability in the wet and fertile meadow, but it promoted perennial grasses with high palatability in the dry and infertile typical steppe. Our findings suggest that the effects of grazing on plant functional traits are dependent on both the abiotic (e.g., soil moisture) and biotic (e.g., plant functional group identity and composition) factors. Grazing-induced shifts in functional group composition are largely dependent on resource

  11. A likelihood ratio test for evolutionary rate shifts and functional divergence among proteins

    PubMed Central

    Knudsen, Bjarne; Miyamoto, Michael M.

    2001-01-01

    Changes in protein function can lead to changes in the selection acting on specific residues. This can often be detected as evolutionary rate changes at the sites in question. A maximum-likelihood method for detecting evolutionary rate shifts at specific protein positions is presented. The method determines significance values of the rate differences to give a sound statistical foundation for the conclusions drawn from the analyses. A statistical test for detecting slowly evolving sites is also described. The methods are applied to a set of Myc proteins for the identification of both conserved sites and those with changing evolutionary rates. Those positions with conserved and changing rates are related to the structures and functions of their proteins. The results are compared with an earlier Bayesian method, thereby highlighting the advantages of the new likelihood ratio tests. PMID:11734650

  12. Effectiveness of interventions to reduce ordering of thyroid function tests: a systematic review.

    PubMed

    Zhelev, Zhivko; Abbott, Rebecca; Rogers, Morwenna; Fleming, Simon; Patterson, Anthea; Hamilton, William Trevor; Heaton, Janet; Thompson Coon, Jo; Vaidya, Bijay; Hyde, Christopher

    2016-06-03

    To evaluate the effectiveness of behaviour changing interventions targeting ordering of thyroid function tests. Systematic review. MEDLINE, EMBASE and the Cochrane Database up to May 2015. We included studies evaluating the effectiveness of behaviour change interventions aiming to reduce ordering of thyroid function tests. Randomised controlled trials (RCTs), non-randomised controlled studies and before and after studies were included. There were no language restrictions. 2 reviewers independently screened all records identified by the electronic searches and reviewed the full text of any deemed potentially relevant. Study details were extracted from the included papers and their methodological quality assessed independently using a validated tool. Disagreements were resolved through discussion and arbitration by a third reviewer. Meta-analysis was not used. 27 studies (28 papers) were included. They evaluated a range of interventions including guidelines/protocols, changes to funding policy, education, decision aids, reminders and audit/feedback; often intervention types were combined. The most common outcome measured was the rate of test ordering, but the effect on appropriateness, test ordering patterns and cost were also measured. 4 studies were RCTs. The majority of the studies were of poor or moderate methodological quality. The interventions were variable and poorly reported. Only 4 studies reported unsuccessful interventions but there was no clear pattern to link effect and intervention type or other characteristics. The results suggest that behaviour change interventions are effective particularly in reducing the volume of thyroid function tests. However, due to the poor methodological quality and reporting of the studies, the likely presence of publication bias and the questionable relevance of some interventions to current day practice, we are unable to draw strong conclusions or recommend the implementation of specific intervention types. Further

  13. Utility of Autonomic Function Tests to Differentiate Dementia with Lewy Bodies and Parkinson Disease with Dementia from Alzheimer Disease.

    PubMed

    Toru, Shuta; Kanouchi, Tadashi; Yokota, Takanori; Yagi, Yosuke; Machida, Akira; Kobayashi, Takayoshi

    2018-01-01

    We studied autonomic disturbance in patients with dementia with Lewy bodies (DLB), Parkinson disease with dementia (PDD), Alzheimer disease (AD), to determine whether autonomic function tests can be used to distinguish these disorders. Autonomic function was tested in 56 patients with DLB, 37 patients with PDD, and 59 patients with AD by using the sympathetic skin response, coefficient of variation in R-R interval, the head-up tilt test, serum norepinephrine concentration, and 123I-meta-iodobenzylguanidine cardiac scintigraphy. Symptoms of autonomic dysfunction, such as constipation, urinary symptoms, and orthostatic hypotension, were also noted. The groups did not differ on baseline characteristics other than those associated with Parkinsonism and dementia. All patients with DLB and PDD had some dysautonomia, whereas rates were much lower for patients with AD (19%). Significantly more DLB and PDD patients than AD patients showed abnormalities on autonomic function tests. Autonomic function tests might be quite useful to distinguish DLB and PDD from AD. © 2017 S. Karger AG, Basel.

  14. Performance on naturalistic virtual reality tasks depends on global cognitive functioning as assessed via traditional neurocognitive tests.

    PubMed

    Oliveira, Jorge; Gamito, Pedro; Alghazzawi, Daniyal M; Fardoun, Habib M; Rosa, Pedro J; Sousa, Tatiana; Picareli, Luís Felipe; Morais, Diogo; Lopes, Paulo

    2017-08-14

    This investigation sought to understand whether performance in naturalistic virtual reality tasks for cognitive assessment relates to the cognitive domains that are supposed to be measured. The Shoe Closet Test (SCT) was developed based on a simple visual search task involving attention skills, in which participants have to match each pair of shoes with the colors of the compartments in a virtual shoe closet. The interaction within the virtual environment was made using the Microsoft Kinect. The measures consisted of concurrent paper-and-pencil neurocognitive tests for global cognitive functioning, executive functions, attention, psychomotor ability, and the outcomes of the SCT. The results showed that the SCT correlated with global cognitive performance as measured with the Montreal Cognitive Assessment (MoCA). The SCT explained one third of the total variance of this test and revealed good sensitivity and specificity in discriminating scores below one standard deviation in this screening tool. These findings suggest that performance of such functional tasks involves a broad range of cognitive processes that are associated with global cognitive functioning and that may be difficult to isolate through paper-and-pencil neurocognitive tests.

  15. On testing for spatial correspondence between maps of human brain structure and function.

    PubMed

    Alexander-Bloch, Aaron F; Shou, Haochang; Liu, Siyuan; Satterthwaite, Theodore D; Glahn, David C; Shinohara, Russell T; Vandekar, Simon N; Raznahan, Armin

    2018-06-01

    A critical issue in many neuroimaging studies is the comparison between brain maps. Nonetheless, it remains unclear how one should test hypotheses focused on the overlap or spatial correspondence between two or more brain maps. This "correspondence problem" affects, for example, the interpretation of comparisons between task-based patterns of functional activation, resting-state networks or modules, and neuroanatomical landmarks. To date, this problem has been addressed with remarkable variability in terms of methodological approaches and statistical rigor. In this paper, we address the correspondence problem using a spatial permutation framework to generate null models of overlap by applying random rotations to spherical representations of the cortical surface, an approach for which we also provide a theoretical statistical foundation. We use this method to derive clusters of cognitive functions that are correlated in terms of their functional neuroatomical substrates. In addition, using publicly available data, we formally demonstrate the correspondence between maps of task-based functional activity, resting-state fMRI networks and gyral-based anatomical landmarks. We provide open-access code to implement the methods presented for two commonly-used tools for surface based cortical analysis (https://www.github.com/spin-test). This spatial permutation approach constitutes a useful advance over widely-used methods for the comparison of cortical maps, thereby opening new possibilities for the integration of diverse neuroimaging data. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. A meta-analysis of perceptual and cognitive functions involved in useful-field-of-view test performance.

    PubMed

    Woutersen, Karlijn; Guadron, Leslie; van den Berg, Albert V; Boonstra, F Nienke; Theelen, Thomas; Goossens, Jeroen

    2017-12-01

    The useful-field-of-view (UFOV) test measures the amount of information someone can extract from a visual scene in one glance. Its scores show relatively strong relationships with everyday activities. The UFOV test consists of three computer tests, suggested to measure processing speed and central vision, divided attention, and selective attention. However, other functions seem to be involved as well. In order to investigate the contribution of these suggested and other perceptual and cognitive functions, we performed a meta-analysis of 116 Pearson's correlation coefficients between UFOV scores and other test scores reported in 18 peer-reviewed articles. We divided these correlations into nine domains: attention, executive functioning, general cognition, memory, spatial ability, visual closure, contrast sensitivity, visual processing speed, and visual acuity. A multivariate mixed-effects model analysis revealed that each domain correlated significantly with each of the UFOV subtest scores. These correlations were stronger for Subtests 2 and 3 than for Subtest 1. Furthermore, some domains were more strongly correlated to the UFOV than others across subtests. We did not find interaction effects between subtest and domain, indicating that none of the UFOV subtests is more selectively sensitive to a particular domain than the others. Thus, none of the three UFOV subtests seem to measure one clear construct. Instead, a range of visual and cognitive functions is involved. Perhaps this is the reason for the UFOV's high ecological validity, as it involves many functions at once, making it harder to compensate if one of them fails.

  17. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    PubMed

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  18. Effect of Mindfulness Meditation on Perceived Stress Scores and Autonomic Function Tests of Pregnant Indian Women.

    PubMed

    Muthukrishnan, Shobitha; Jain, Reena; Kohli, Sangeeta; Batra, Swaraj

    2016-04-01

    Various pregnancy complications like hypertension, preeclampsia have been strongly correlated with maternal stress. One of the connecting links between pregnancy complications and maternal stress is mind-body intervention which can be part of Complementary and Alternative Medicine (CAM). Biologic measures of stress during pregnancy may get reduced by such interventions. To evaluate the effect of Mindfulness meditation on perceived stress scores and autonomic function tests of pregnant Indian women. Pregnant Indian women of 12 weeks gestation were randomised to two treatment groups: Test group with Mindfulness meditation and control group with their usual obstetric care. The effect of Mindfulness meditation on perceived stress scores and cardiac sympathetic functions and parasympathetic functions (Heart rate variation with respiration, lying to standing ratio, standing to lying ratio and respiratory rate) were evaluated on pregnant Indian women. There was a significant decrease in perceived stress scores, a significant decrease of blood pressure response to cold pressor test and a significant increase in heart rate variability in the test group (p< 0.05, significant) which indicates that mindfulness meditation is a powerful modulator of the sympathetic nervous system and can thereby reduce the day-to-day perceived stress in pregnant women. The results of this study suggest that mindfulness meditation improves parasympathetic functions in pregnant women and is a powerful modulator of the sympathetic nervous system during pregnancy.

  19. Method and apparatus for transfer function simulator for testing complex systems

    NASA Technical Reports Server (NTRS)

    Kavaya, M. J. (Inventor)

    1985-01-01

    A method and apparatus for testing the operation of a complex stabilization circuit in a closed loop system is presented. The method is comprised of a programmed analog or digital computing system for implementing the transfer function of a load thereby providing a predictable load. The digital computing system employs a table stored in a microprocessor in which precomputed values of the load transfer function are stored for values of input signal from the stabilization circuit over the range of interest. This technique may be used not only for isolating faults in the stabilization circuit, but also for analyzing a fault in a faulty load by so varying parameters of the computing system as to simulate operation of the actual load with the fault.

  20. Reducing liver function tests for statin monitoring: an observational comparison of two clinical commissioning groups.

    PubMed

    Homer, Kate; Robson, John; Solaiman, Susannah; Davis, Abigail; Khan, Saima Zubeda; McCoy, David; Mathur, Rohini; Hull, Sally; Boomla, Kambiz

    2017-03-01

    Current liver function testing for statin monitoring is largely unnecessary and costly. Statins do not cause liver disease. Both reduction in test frequency and use of a single alanine transaminase (ALT) rather than a full seven analyte liver function test (LFT) array would reduce cost and may benefit patients. To assess LFT testing in relation to statin use and evaluate an intervention to reduce full-array LFTs ordered by GPs for statin monitoring. Two-year cross-sectional time series in two east London clinical commissioning groups (CCGs) with 650 000 patients. One CCG received the intervention; the other did not. The intervention comprised local guidance on LFTs for statin monitoring and access to a single ALT rather than full LFT array. Of the total population, 17.6% were on statins, accounting for 43.2% of total LFTs. In the population without liver disease, liver function tests were 3.6 times higher for those on statins compared with those who were not. Following intervention there was a significant reduction in the full LFT array per 1000 people on statins, from 70.3 (95% confidence interval [CI] = 66.3 to 74.6) in the pre-intervention year, to 58.1 (95% CI = 55.5 to 60.7) in the post-intervention year ( P <0.001). In the final month, March 2016, the rate was 53.2, a 24.3% reduction on the pre-intervention rate. This simple and generalisable intervention, enabling ordering of a single ALT combined with information recommending prudent rather than periodic testing, reduced full LFT testing by 24.3% in people on statins. This is likely to have patient benefit at reduced cost. © British Journal of General Practice 2017.

  1. Fluctuating serotonergic function in premenstrual dysphoric disorder and premenstrual syndrome: findings from neuroendocrine challenge tests.

    PubMed

    Inoue, Y; Terao, T; Iwata, N; Okamoto, K; Kojima, H; Okamoto, T; Yoshimura, R; Nakamura, J

    2007-02-01

    Premenstrual dysphoric disorder (PMDD) has been assumed to be a subtype of premenstrual syndrome (PMS) with depressive symptoms, such as depressive mood, tension, anxiety, and mood liability during luteal phase. At present, no conclusion has been established about serotonergic function in PMDD. The purpose of this study was to investigate the serotonergic function of PMDD subjects in comparison to PMS without PMDD subjects and normal controls via neuroendocrine challenge tests. Twenty-four women (seven with PMDD, eight with PMS without PMDD, and nine normal controls) were tested on three occasions (follicular phase, early luteal phase, and late luteal phase) receiving paroxetine 20 mg orally as a serotonergic probe at 8:00 A: .M: . Plasma ACTH and cortisol were measured prior to the administration and every hour for 6 h thereafter. As a whole, there were significant differences in serotonergic function measured by ACTH and cortisol responses to paroxetine challenge across these three groups. PMDD subjects showed higher serotonergic function in follicular phase but lower serotonergic function in luteal phase, compared with women with PMS without PMDD and normal controls. The present findings suggest that PMDD women have fluctuating serotonergic function across their menstrual cycles and that the pattern may be different from PMS without PMDD.

  2. [The clinicopathological analysis of 88 patients with abnormal liver function test of unknown etiology].

    PubMed

    Pang, Shu-zhen; Ou, Xiao-juan; Shi, Xiao-yan; Wang, Tai-ling; Duan, Wei-jia; Jia, Ji-dong

    2011-01-01

    To evaluate the clinical and histological features of patients with abnormal liver tests of unknown etiology, and then to investigate the diagnosis and differential diagnosis. Patients with abnormal liver function test hospitalized and had liver biopsies during 2008 - 2009 constituted this retrospective study cohort. After excluding those patients diagnosed with hepatotropic viral hepatitis, space occupying lesions of the liver, alcoholic liver disease and obstruction of bile duct caused by stone or malignancy and AMA/AMA-M(2) positive of primary biliary cirrhosis (PBC), the clinical and histological characteristics were evaluated. Out of the 180 patients who underwent liver biopsy, 88 patients were included in the present analysis. The final diagnosis involved 15 categories of diseases, with drug-induced liver injury (DILI) [34.09% (30/88)], autoimmune liver diseases [22.73% (20/88)], and nonalcoholic fatty liver disease (NAFLD) [12.50% (11/88)] being the most common causes, following by genetic and other rare diseases. DILI, autoimmune liver disease and NAFLD were the most common causes of abnormal liver tests in these non-viral liver diseases. Some rare diseases such as hereditary metabolic liver disease also represent a considerable proportion in patients with abnormal liver function test.

  3. Techniques and Methods for Testing the Postural Function in Healthy and Pathological Subjects

    PubMed Central

    Paillard, Thierry; Noé, Frédéric

    2015-01-01

    The different techniques and methods employed as well as the different quantitative and qualitative variables measured in order to objectify postural control are often chosen without taking into account the population studied, the objective of the postural test, and the environmental conditions. For these reasons, the aim of this review was to present and justify the different testing techniques and methods with their different quantitative and qualitative variables to make it possible to precisely evaluate each sensory, central, and motor component of the postural function according to the experiment protocol under consideration. The main practical and technological methods and techniques used in evaluating postural control were explained and justified according to the experimental protocol defined. The main postural conditions (postural stance, visual condition, balance condition, and test duration) were also analyzed. Moreover, the mechanistic exploration of the postural function often requires implementing disturbing postural conditions by using motor disturbance (mechanical disturbance), sensory stimulation (sensory manipulation), and/or cognitive disturbance (cognitive task associated with maintaining postural balance) protocols. Each type of disturbance was tackled in order to facilitate understanding of subtle postural control mechanisms and the means to explore them. PMID:26640800

  4. Techniques and Methods for Testing the Postural Function in Healthy and Pathological Subjects.

    PubMed

    Paillard, Thierry; Noé, Frédéric

    2015-01-01

    The different techniques and methods employed as well as the different quantitative and qualitative variables measured in order to objectify postural control are often chosen without taking into account the population studied, the objective of the postural test, and the environmental conditions. For these reasons, the aim of this review was to present and justify the different testing techniques and methods with their different quantitative and qualitative variables to make it possible to precisely evaluate each sensory, central, and motor component of the postural function according to the experiment protocol under consideration. The main practical and technological methods and techniques used in evaluating postural control were explained and justified according to the experimental protocol defined. The main postural conditions (postural stance, visual condition, balance condition, and test duration) were also analyzed. Moreover, the mechanistic exploration of the postural function often requires implementing disturbing postural conditions by using motor disturbance (mechanical disturbance), sensory stimulation (sensory manipulation), and/or cognitive disturbance (cognitive task associated with maintaining postural balance) protocols. Each type of disturbance was tackled in order to facilitate understanding of subtle postural control mechanisms and the means to explore them.

  5. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    NASA Technical Reports Server (NTRS)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  6. Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brennan, Douglas; Schubert, Leah; Diot, Quentin

    Purpose: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. Methods and Materials: Ninety-eight lung cancer patients withmore » pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change–based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. Results: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. Conclusions: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating

  7. Diagnostic disagreement between tests of evacuatory function: a prospective study of 100 constipated patients.

    PubMed

    Palit, S; Thin, N; Knowles, C H; Lunniss, P J; Bharucha, A E; Scott, S M

    2016-10-01

    Evacuatory dysfunction (ED) is a common cause of constipation and may be sub-classified on the basis of specialist tests. Such tests may guide treatment e.g., biofeedback therapy for 'functional' defecatory disorders (FDD). However, there is no gold standard, and prior studies have not prospectively and systematically compared all tests that are used to diagnose forms of ED. One hundred consecutive patients fulfilling Rome III criteria for functional constipation underwent four tests: expulsion of a rectal balloon distended to 50 mL (BE50 ) or until patients experienced the desire to defecate (BEDDV ), evacuation proctography (EP) and anorectal manometry. Yields and agreements between tests for the diagnosis of ED and FDD were assessed. Positive diagnostic yields for ED were: BEDDV 18%, BE50 31%, EP 38% and anorectal manometry (ARM) 68%. Agreement was substantial between the two balloon tests (k = 0.66), only fair between proctography and BE50 (k = 0.27), poor between manometry and proctography (k = 0.01), and there was no agreement between the balloon tests and manometry (k = -0.07 for both BE50 and BEDDV ). For the diagnosis of FDD, there was only fair agreement between ARM and EP (k = 0.23), ARM ± BE50 and EP (k = 0.18), ARM and EP ± BE50 (k = 0.30) and ARM ± BE50 and EP ± BE50 (k = 0.23). There is considerable disagreement between the results of various tests used to diagnose ED and FDD. This highlights the need for a reappraisal of both diagnostic criteria, and what represents the 'gold standard' investigation. © 2016 John Wiley & Sons Ltd.

  8. On the Power Functions of Test Statistics in Order Restricted Inference.

    DTIC Science & Technology

    1984-10-01

    California-Davis Actuarial Science Davis, California 95616 The University of Iowa Iowa City, Iowa 52242 *F. T. Wright Department of Mathematics and...34 SUMMARY --We study the power functions of both the likelihood ratio and con- trast statistics for detecting a totally ordered trend in a collection...samples from normal populations, Bartholomew (1959 a,b; 1961) studied the likelihood ratio tests (LRTs) for H0 versus H -H assuming in one case that

  9. Criteria for distinguishing normal and subnormal adrenocortical function using the Synacthen test

    PubMed Central

    Greig, W. R.; Boyle, J. A.; Maxwell, J. D.; Lindsay, R. M.; Browning, Margaret C. K.

    1969-01-01

    The Synacthen test consists of the measurement of plasma corticosteroid concentrations by a fluorimetric method before (basal) and 30 min after a single intramuscular administration of 250 μg of tetracosactrin (Synacthen), a synthetic polypeptide with ACTH activity equivalent to that of natural corticotrophin. In a control group of forty-five subjects the basal plasma corticosteroid level was not lower than 6 μg/100 ml (a lower limit of 5 μg/100 ml is accepted in the afternoon and evening), the increment was not less than 7 μg/100 ml and the plasma corticosteroid concentration after Synacthen was not less than 18 μg/100 ml. From these results the ‘6 (5), 7, 18’ rule was formulated and any patient who failed to satisfy at least two of these criteria was considered to have adrenocortical insufficiency. The results of the Synacthen test were assessed in forty-six patients who had received long-term steroid therapy, and in fifteen patients with suspected or proven pituitary failure or Addison's disease. Using the ‘6 (5), 7, 18’ rule patients who satisfied two or more of the criteria were considered as having normal adrenal function, while patients who failed to satisfy these criteria were diagnosed as having adrenal insufficiency. This separation of patients into those with normal and subnormal adrenal function on the basis of the Synacthen test results was found to be reliable as the same division was obtained when the corticotrophin infusion test was performed on groups of the same patients. The Synacthen test was also carried out in a group of eighty ill patients who did not appear clinically to have endocrine disease and it was considered that the criteria previously determined for distinguishing between a normal and subnormal response to Synacthen were also applicable to this group of patients. It is suggested that using these criteria the Synacthen test is a simple and reliable screening procedure for the detection or exclusion of adrenocortical

  10. Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    PubMed

    Borrat, Xavier; Ubre, Marta; Risco, Raquel; Gambús, Pedro L; Pedroso, Angela; Iglesias, Aina; Fernandez-Esparrach, Gloria; Ginés, Àngels; Balust, Jaume; Martínez-Palli, Graciela

    2018-03-27

    The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge

  11. Executive Function and ADHD: A Comparison of Children's Performance during Neuropsychological Testing and Real-World Activities

    ERIC Educational Resources Information Center

    Lawrence, Vivienne; Houghton, Stephen; Douglas, Graham; Durkin, Kevin; Whiting, Ken; Tannock, Rosemary

    2004-01-01

    Objective: Current understanding of executive function deficits in Attention-Deficit/Hyperactivity Disorder (ADHD) is derived almost exclusively from neuropsychological testing conducted in laboratory settings. This study compared children's performance on both neuropsychological and real-life measures of executive function and processing speed.…

  12. A battery of tests for assessing cognitive function in U.S. Chinese older adults--findings from the PINE Study.

    PubMed

    Chang, E-Shien; Dong, XinQi

    2014-11-01

    Existing methodological challenges in aging research has dampened our assessment of cognitive function among minority older adults. We aim to report the composite scores of five cognitive function tests among U.S. Chinese older adults, and examine the association between cognitive function and key sociodemographic characteristics. The Population Study of Chinese Elderly in Chicago Study enrolled an epidemiological cohort of 3,159 community-dwelling Chinese older adults. We administered five cognitive function tests, including the Chinese Mini-Mental State Examination, the immediate and delayed recall of the East Boston Memory Test, the Digit Span Backwards assessment, and the Symbol Digit Modalities Test. We used Spearman correlation coefficients to examine the correlation between cognitive function and sociodemographic variables. Linear regression models were used to report the effect of sociodemographic and health variables including age, sex, education on cognitive function. Our multivariate analysis suggested that performance in each domain of cognitive function was inversely associated with age and positively related to education. With respect to sex, after adjusted for age, education and all key variables presented in the model, being male was positively related to global cognitive score and working memory. Being married, having fewer children, having been in the United States for fewer years, having been in the community for fewer years, and better self-reported health were positively correlated with all cognitive function domains. This population-based study of U.S. Chinese older adults is among the first to examine a battery of five cognitive function tests, which in aggregate enables researchers to capture a wide range of cognitive performance. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Testing hypotheses of bat baculum function with 3D models derived from microCT

    PubMed Central

    Herdina, Anna Nele; Kelly, Diane A; Jahelková, Helena; Lina, Peter H C; Horáček, Ivan; Metscher, Brian D

    2015-01-01

    The baculum (os penis) has been extensively studied as a taxon-specific character in bats and other mammals but its mechanical function is still unclear. There is a wide consensus in the literature that the baculum is probably a sexually selected character. Using a novel approach combining postmortem manipulation and three-dimensional (3D) imaging, we tested two functional hypotheses in the common noctule bat Nyctalus noctula, the common pipistrelle Pipistrellus pipistrellus, and Nathusius’ pipistrelle Pipistrellus nathusii: (i) whether the baculum can protect the distal urethra and urethral opening from compression during erection and copulation; and (ii) whether the baculum and corpora cavernosa form a functional unit to support both the penile shaft and the more distal glans tip. In freshly dead or frozen and thawed bats, we compared flaccid penises with artificially ‘erect’ penises that were inflated with 10% formalin. Penises were stained with alcoholic iodine and imaged with a lab-based high-resolution x-ray microtomography system. Analysis of the 3D images enabled us to compare the changes in relative positions of the baculum, corpora cavernosa, urethra, and corpus spongiosum with one another between flaccid and ‘erect’ penises. Our results support both functional hypotheses, indicating that the baculum probably performs two different roles during erection. Our approach should prove valuable for comparing and testing the functions of different baculum morphologies in bats and other mammals. Moreover, we have validated an essential component of the groundwork necessary to extend this approach with finite element analysis for quantitative 3D biomechanical modeling of penis function. PMID:25655647

  14. Validity and Reliability of the Italian Version of the Functioning Assessment Short Test (FAST) in Bipolar Disorder

    PubMed Central

    Moro, Maria Francesca; Colom, Francesc; Floris, Francesca; Pintus, Elisa; Pintus, Mirra; Contini, Francesca; Carta, Mauro Giovanni

    2012-01-01

    Background: Functioning Assessment Short Test (FAST) is a brief instrument designed to assess the main functioning problems experienced by psychiatric patients, specifically bipolar patients. It includes 24 items assessing impairment or disability in six domains of functioning: autonomy, occupational functioning, cognitive functioning, financial issues, interpersonal relationships and leisure time. The aim of this study is to measure the validity and reliability of the Italian version of this instrument. Methods: Twenty-four patients with DSM-IV TR bipolar disorder and 20 healthy controls were recruited and evaluated in three private clinics in Cagliari (Sardinia, Italy). The psychometric properties of FAST (feasibility, internal consistency, concurrent validity, discriminant validity (patients vs controls and eutimic patients vs manic and depressed), and test-retest reliability were analyzed. Results: The internal consistency obtained was very high with a Cronbach's alpha of 0.955. A highly significant negative correlation with GAF was obtained (r = -0.9; p < 0.001) pointing to a reasonable degree of concurrent validity. FAST show a good test-retest reliability between two independent evaluation differing of one week (mean K =0.73). The total FAST scores were lower in controls as compared with Bipolar Patients and in Euthimic patients compared with Depressed or Manic. Conclusion: The Italian version of the FAST showed similar psychometrics properties as far as regard internal consistency and discriminant validity of the original version and show a good test retest reliability measure by means of K statistics. PMID:22905035

  15. Using computational fluid dynamics to test functional and ecological hypotheses in fossil taxa

    NASA Astrophysics Data System (ADS)

    Rahman, Imran

    2016-04-01

    Reconstructing how ancient organisms moved and fed is a major focus of study in palaeontology. Traditionally, this has been hampered by a lack of objective data on the functional morphology of extinct species, especially those without a clear modern analogue. However, cutting-edge techniques for characterizing specimens digitally and in three dimensions, coupled with state-of-the-art computer models, now provide a robust framework for testing functional and ecological hypotheses even in problematic fossil taxa. One such approach is computational fluid dynamics (CFD), a method for simulating fluid flows around objects that has primarily been applied to complex engineering-design problems. Here, I will present three case studies of CFD applied to fossil taxa, spanning a range of specimen sizes, taxonomic groups and geological ages. First, I will show how CFD enabled a rigorous test of hypothesized feeding modes in an enigmatic Ediacaran organism with three-fold symmetry, revealing previously unappreciated complexity of pre-Cambrian ecosystems. Second, I will show how CFD was used to evaluate hydrodynamic performance and feeding in Cambrian stem-group echinoderms, shedding light on the probable feeding strategy of the latest common ancestor of all deuterostomes. Third, I will show how CFD allowed us to explore the link between form and function in Mesozoic ichthyosaurs. These case studies serve to demonstrate the enormous potential of CFD for addressing long-standing hypotheses for a variety of fossil taxa, opening up an exciting new avenue in palaeontological studies of functional morphology.

  16. Functional limitations in Romanian children with haemophilia: further testing of psychometric properties of the Paediatric Haemophilia Activities List.

    PubMed

    Groen, W; van der Net, J; Lacatusu, A M; Serban, M; Helders, P J M; Fischer, K

    2013-05-01

    Children with haemophilia often experience limitations in activities of daily life. Recently the Paediatric Haemophilia Activities List (PedHAL) has been developed and tested in Dutch children with intensive replacement therapy. The psychometric properties of the PedHAL in children not receiving intensive replacement therapy are not known. The objective was to gain further insight into the psychometric properties of the PedHAL and to study the functional health status of Romanian children and adolescents with haemophilia. Children attending to the rehabilitation centre of Buzias in Romania were sampled consecutively. Construct validity of the PedHAL was evaluated by concurrent testing with objective and subjective measures of physical function and functional ability. Reproducibility was tested by a 3-day test-retest by intraclass correlation coefficient (ICC) and limits of agreement (LOA). Responsiveness to rehabilitation was assessed by Haemophilia Joint Health Score (HJHS) and PedHAL. Twenty-nine children with severe (n = 25) or moderate (n = 4) haemophilia participated. Mean age was 13.2 years (SD 4.0). Median score of the PedHAL was 83.5 (IQR 47.9-90.5). The PedHAL correlated moderately with HJHS (rho = -0.59), Functional Independence Score in& Haemophilia (rho = 0.65) and Child Health Questionnaire-physical function (rho = 0.40) and not with Child Health Questionnaire-mental health, Child Health Questionnaire-behaviour and 6MWT. Test-retest reliability was good (ICC = 0.95). LOA was 17.4 points for the sum score. HJHS scores improved slightly after rehabilitation, whereas PedHAL scores did not change. In general, construct validity and test-retest reliability were good, test-retest agreement showed some variability. Therefore, currently the PedHAL may be more appropriate for research purposes than for individual patient monitoring in clinical practice. © 2013 Blackwell Publishing Ltd.

  17. Functional Equivalence Acceptance Testing of FUN3D for Entry Descent and Landing Applications

    NASA Technical Reports Server (NTRS)

    Gnoffo, Peter A.; Wood, William A.; Kleb, William L.; Alter, Stephen J.; Glass, Christopher E.; Padilla, Jose F.; Hammond, Dana P.; White, Jeffery A.

    2013-01-01

    The functional equivalence of the unstructured grid code FUN3D to the the structured grid code LAURA (Langley Aerothermodynamic Upwind Relaxation Algorithm) is documented for applications of interest to the Entry, Descent, and Landing (EDL) community. Examples from an existing suite of regression tests are used to demonstrate the functional equivalence, encompassing various thermochemical models and vehicle configurations. Algorithm modifications required for the node-based unstructured grid code (FUN3D) to reproduce functionality of the cell-centered structured code (LAURA) are also documented. Challenges associated with computation on tetrahedral grids versus computation on structured-grid derived hexahedral systems are discussed.

  18. Repeatability and validity of a standardised maximal step-up test for leg function-a diagnostic accuracy study

    PubMed Central

    2011-01-01

    Background Objectively assessed physical performance is a strong predictor for morbidity and premature death and there is an increasing interest in the role of sarcopenia in many chronic diseases. There is a need for robust and valid functional tests in clinical practice. Therefore, the repeatability and validity of a newly developed maximal step up test (MST) was assessed. Methods The MST, assessing maximal step-up height (MSH) in 3-cm increments, was evaluated in 60 healthy middle-aged subjects, 30 women and 30 men. The repeatability of MSH and the correlation between MSH and isokinetic knee extension peak torque (IKEPT), self-reported physical function (SF-36, PF), patient demographics and self-reported physical activity were investigated. Results The repeatability between occasions and between testers was 6 cm. MSH (range 12-45 cm) was significantly correlated to IKEPT, (r = 0.68, P < 0.001), SF-36 PF score, (r = 0.29, P = 0.03), sex, age, weight and BMI. The results also show that MSH above 32 cm discriminates subjects in our study with no limitation in self-reported physical function. Conclusions The standardised MST is considered a reliable leg function test for clinical practice. The MSH was related to knee extension strength and self-reported physical function. The precision of the MST for identification of limitations in physical function needs further investigation. PMID:21854575

  19. Multiloop Integral System Test (MIST): MIST Facility Functional Specification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habib, T F; Koksal, C G; Moskal, T E

    1991-04-01

    The Multiloop Integral System Test (MIST) is part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox designed plants. MIST is sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral facilities to address the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility --more » the Once Through Integral System (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST Functional Specification documents as-built design features, dimensions, instrumentation, and test approach. It also presents the scaling basis for the facility and serves to define the scope of work for the facility design and construction. 13 refs., 112 figs., 38 tabs.« less

  20. Decreased prefrontal functional brain response during memory testing in women with Cushing's syndrome in remission.

    PubMed

    Ragnarsson, Oskar; Stomby, Andreas; Dahlqvist, Per; Evang, Johan A; Ryberg, Mats; Olsson, Tommy; Bollerslev, Jens; Nyberg, Lars; Johannsson, Gudmundur

    2017-08-01

    Neurocognitive dysfunction is an important feature of Cushing's syndrome (CS). Our hypothesis was that patients with CS in remission have decreased functional brain responses in the prefrontal cortex and hippocampus during memory testing. In this cross-sectional study we included 19 women previously treated for CS and 19 controls matched for age, gender, and education. The median remission time was 7 (IQR 6-10) years. Brain activity was studied with functional magnetic resonance imaging during episodic- and working-memory tasks. The primary regions of interest were the prefrontal cortex and the hippocampus. A voxel-wise comparison of functional brain responses in patients and controls was performed. During episodic-memory encoding, patients displayed lower functional brain responses in the left and right prefrontal gyrus (p<0.001) and in the right inferior occipital gyrus (p<0.001) compared with controls. There was a trend towards lower functional brain responses in the left posterior hippocampus in patients (p=0.05). During episodic-memory retrieval, the patients displayed lower functional brain responses in several brain areas with the most predominant difference in the right prefrontal cortex (p<0.001). During the working memory task, patients had lower response in the prefrontal cortices bilaterally (p<0.005). Patients, but not controls, had lower functional brain response during a more complex working memory task compared with a simpler one. In conclusion, women with CS in long-term remission have reduced functional brain responses during episodic and working memory testing. This observation extends previous findings showing long-term adverse effects of severe hypercortisolaemia on brain function. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. In silico experiment system for testing hypothesis on gene functions using three condition specific biological networks.

    PubMed

    Lee, Chai-Jin; Kang, Dongwon; Lee, Sangseon; Lee, Sunwon; Kang, Jaewoo; Kim, Sun

    2018-05-25

    Determining functions of a gene requires time consuming, expensive biological experiments. Scientists can speed up this experimental process if the literature information and biological networks can be adequately provided. In this paper, we present a web-based information system that can perform in silico experiments of computationally testing hypothesis on the function of a gene. A hypothesis that is specified in English by the user is converted to genes using a literature and knowledge mining system called BEST. Condition-specific TF, miRNA and PPI (protein-protein interaction) networks are automatically generated by projecting gene and miRNA expression data to template networks. Then, an in silico experiment is to test how well the target genes are connected from the knockout gene through the condition-specific networks. The test result visualizes path from the knockout gene to the target genes in the three networks. Statistical and information-theoretic scores are provided on the resulting web page to help scientists either accept or reject the hypothesis being tested. Our web-based system was extensively tested using three data sets, such as E2f1, Lrrk2, and Dicer1 knockout data sets. We were able to re-produce gene functions reported in the original research papers. In addition, we comprehensively tested with all disease names in MalaCards as hypothesis to show the effectiveness of our system. Our in silico experiment system can be very useful in suggesting biological mechanisms which can be further tested in vivo or in vitro. http://biohealth.snu.ac.kr/software/insilico/. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. The Leuven Embedded Figures Test (L-EFT): measuring perception, intelligence or executive function?

    PubMed Central

    Van der Hallen, Ruth; Wagemans, Johan; de-Wit, Lee; Chamberlain, Rebecca

    2018-01-01

    Performance on the Embedded Figures Test (EFT) has been interpreted as a reflection of local/global perceptual style, weak central coherence and/or field independence, as well as a measure of intelligence and executive function. The variable ways in which EFT findings have been interpreted demonstrate that the construct validity of this measure is unclear. In order to address this lack of clarity, we investigated to what extent performance on a new Embedded Figures Test (L-EFT) correlated with measures of intelligence, executive functions and estimates of local/global perceptual styles. In addition, we compared L-EFT performance to the original group EFT to directly contrast both tasks. Taken together, our results indicate that performance on the L-EFT does not correlate strongly with estimates of local/global perceptual style, intelligence or executive functions. Additionally, the results show that performance on the L-EFT is similarly associated with memory span and fluid intelligence as the group EFT. These results suggest that the L-EFT does not reflect a general perceptual or cognitive style/ability. These results further emphasize that empirical data on the construct validity of a task do not always align with the face validity of a task. PMID:29607257

  3. HIV Testing Behavior and Social Network Characteristics and Functions Among Young Men Who have Sex with Men (YMSM) in Metropolitan Detroit.

    PubMed

    Veinot, Tiffany C; Caldwell, Ebony; Loveluck, Jimena; Arnold, Michael P; Bauermeister, José

    2016-11-01

    HIV testing promotion is a critical HIV prevention strategy, especially among at-risk groups such as young men who have sex with men (YMSM). Based on a web survey of 194 YMSM (18-24), we examine the association of social network characteristics and functions, and of individual-level characteristics, with three HIV testing behaviors (ever, repeat, and recent testing). Network homophily was associated with recent testing in multivariable models. The network function of information acquisition was associated with ever testing and repeat testing. Perceived stigma regarding HIV-related help-seeking was negatively related to recent testing. Individual characteristics were associated with testing outcomes in all models; age, perceived behavioral control, and positive attitudes had the greatest influence. Individual characteristics had a stronger association with ever testing and repeat testing than network characteristics and functions; however, this relationship was reversed for recent testing. Findings support the value of multi-level and network-focused interventions for promoting HIV testing among YMSM.

  4. HIV Testing Behavior and Social Network Characteristics and Functions Among Young Men Who have Sex with Men (YMSM) in Metropolitan Detroit

    PubMed Central

    Caldwell, Ebony; Loveluck, Jimena; Arnold, Michael P.; Bauermeister, José

    2016-01-01

    HIV testing promotion is a critical HIV prevention strategy, especially among at-risk groups such as young men who have sex with men (YMSM). Based on a web survey of 194 YMSM (18–24), we examine the association of social network characteristics and functions, and of individual-level characteristics, with three HIV testing behaviors (ever, repeat, and recent testing). Network homophily was associated with recent testing in multivariable models. The network function of information acquisition was associated with ever testing and repeat testing. Perceived stigma regarding HIV-related help-seeking was negatively related to recent testing. Individual characteristics were associated with testing outcomes in all models; age, perceived behavioral control, and positive attitudes had the greatest influence. Individual characteristics had a stronger association with ever testing and repeat testing than network characteristics and functions; however, this relationship was reversed for recent testing. Findings support the value of multi-level and network-focused interventions for promoting HIV testing among YMSM. PMID:26837634

  5. Development and testing of transfer functions for generating quantitative climatic estimates from Australian pollen data

    NASA Astrophysics Data System (ADS)

    Cook, Ellyn J.; van der Kaars, Sander

    2006-10-01

    We review attempts to derive quantitative climatic estimates from Australian pollen data, including the climatic envelope, climatic indicator and modern analogue approaches, and outline the need to pursue alternatives for use as input to, or validation of, simulations by models of past, present and future climate patterns. To this end, we have constructed and tested modern pollen-climate transfer functions for mainland southeastern Australia and Tasmania using the existing southeastern Australian pollen database and for northern Australia using a new pollen database we are developing. After testing for statistical significance, 11 parameters were selected for mainland southeastern Australia, seven for Tasmania and six for northern Australia. The functions are based on weighted-averaging partial least squares regression and their predictive ability evaluated against modern observational climate data using leave-one-out cross-validation. Functions for summer, annual and winter rainfall and temperatures are most robust for southeastern Australia, while in Tasmania functions for minimum temperature of the coldest period, mean winter and mean annual temperature are the most reliable. In northern Australia, annual and summer rainfall and annual and summer moisture indexes are the strongest. The validation of all functions means all can be applied to Quaternary pollen records from these three areas with confidence. Copyright

  6. Functional assessment of the ex vivo vocal folds through biomechanical testing: A review

    PubMed Central

    Dion, Gregory R.; Jeswani, Seema; Roof, Scott; Fritz, Mark; Coelho, Paulo; Sobieraj, Michael; Amin, Milan R.; Branski, Ryan C.

    2016-01-01

    The human vocal folds are complex structures made up of distinct layers that vary in cellular and extracellular composition. The mechanical properties of vocal fold tissue are fundamental to the study of both the acoustics and biomechanics of voice production. To date, quantitative methods have been applied to characterize the vocal fold tissue in both normal and pathologic conditions. This review describes, summarizes, and discusses the most commonly employed methods for vocal fold biomechanical testing. Force-elongation, torsional parallel plate rheometry, simple-shear parallel plate rheometry, linear skin rheometry, and indentation are the most frequently employed biomechanical tests for vocal fold tissues and each provide material properties data that can be used to compare native tissue verses diseased for treated tissue. Force-elongation testing is clinically useful, as it allows for functional unit testing, while rheometry provides physiologically relevant shear data, and nanoindentation permits micrometer scale testing across different areas of the vocal fold as well as whole organ testing. Thoughtful selection of the testing technique during experimental design to evaluate a hypothesis is important to optimizing biomechanical testing of vocal fold tissues. PMID:27127075

  7. Examining Differential Item Functions of Different Item Ordered Test Forms According to Item Difficulty Levels

    ERIC Educational Resources Information Center

    Çokluk, Ömay; Gül, Emrah; Dogan-Gül, Çilem

    2016-01-01

    The study aims to examine whether differential item function is displayed in three different test forms that have item orders of random and sequential versions (easy-to-hard and hard-to-easy), based on Classical Test Theory (CTT) and Item Response Theory (IRT) methods and bearing item difficulty levels in mind. In the correlational research, the…

  8. Minimum Performance on Clinical Tests of Physical Function to Predict Walking 6,000 Steps/Day in Knee Osteoarthritis: An Observational Study.

    PubMed

    Master, Hiral; Thoma, Louise M; Christiansen, Meredith B; Polakowski, Emily; Schmitt, Laura A; White, Daniel K

    2018-07-01

    Evidence of physical function difficulties, such as difficulty rising from a chair, may limit daily walking for people with knee osteoarthritis (OA). The purpose of this study was to identify minimum performance thresholds on clinical tests of physical function predictive to walking ≥6,000 steps/day. This benchmark is known to discriminate people with knee OA who develop functional limitation over time from those who do not. Using data from the Osteoarthritis Initiative, we quantified daily walking as average steps/day from an accelerometer (Actigraph GT1M) worn for ≥10 hours/day over 1 week. Physical function was quantified using 3 performance-based clinical tests: 5 times sit-to-stand test, walking speed (tested over 20 meters), and 400-meter walk test. To identify minimum performance thresholds for daily walking, we calculated physical function values corresponding to high specificity (80-95%) to predict walking ≥6,000 steps/day. Among 1,925 participants (mean ± SD age 65.1 ± 9.1 years, mean ± SD body mass index 28.4 ± 4.8 kg/m 2 , and 55% female) with valid accelerometer data, 54.9% walked ≥6,000 steps/day. High specificity thresholds of physical function for walking ≥6,000 steps/day ranged 11.4-14.0 seconds on the 5 times sit-to-stand test, 1.13-1.26 meters/second for walking speed, or 315-349 seconds on the 400-meter walk test. Not meeting these minimum performance thresholds on clinical tests of physical function may indicate inadequate physical ability to walk ≥6,000 steps/day for people with knee OA. Rehabilitation may be indicated to address underlying impairments limiting physical function. © 2017, American College of Rheumatology.

  9. A novel apparatus for testing binocular function using the 'CyberDome' three-dimensional hemispherical visual display system.

    PubMed

    Handa, T; Ishikawa, H; Shimizu, K; Kawamura, R; Nakayama, H; Sawada, K

    2009-11-01

    Virtual reality has recently been highlighted as a promising medium for visual presentation and entertainment. A novel apparatus for testing binocular visual function using a hemispherical visual display system, 'CyberDome', has been developed and tested. Subjects comprised 40 volunteers (mean age, 21.63 years) with corrected visual acuity of -0.08 (LogMAR) or better, and stereoacuity better than 100 s of arc on the Titmus stereo test. Subjects were able to experience visual perception like being surrounded by visual images, a feature of the 'CyberDome' hemispherical visual display system. Visual images to the right and left eyes were projected and superimposed on the dome screen, allowing test images to be seen independently by each eye using polarizing glasses. The hemispherical visual display was 1.4 m in diameter. Three test parameters were evaluated: simultaneous perception (subjective angle of strabismus), motor fusion amplitude (convergence and divergence), and stereopsis (binocular disparity at 1260, 840, and 420 s of arc). Testing was performed in volunteer subjects with normal binocular vision, and results were compared with those using a major amblyoscope. Subjective angle of strabismus and motor fusion amplitude showed a significant correlation between our test and the major amblyoscope. All subjects could perceive the stereoscopic target with a binocular disparity of 480 s of arc. Our novel apparatus using the CyberDome, a hemispherical visual display system, was able to quantitatively evaluate binocular function. This apparatus offers clinical promise in the evaluation of binocular function.

  10. [Biochemical profile of the pancreatic function: pancreolauril and oral glucose tolerance tests].

    PubMed

    Beatriz Di Carlo, Maria; López Mingorance, Fabiana N; del Carmen Maselli, M; Hamamura, Susana; Otero, Graciela; Tiscornia, Osvaldo M; Negri, Gustavo A

    2010-06-01

    The pancreas is a mixed gland that takes part in the digestion of nutrients and in the homeostasis ofglycemia. Chronic pancreopathy is the cause of secretory insufficiency, characterized by an inflammatory process that leads to fibrosis of the pancreas, with a progressive loss of both exocrine and endocrine functions of the gland. To study both the exocrine and endocrine pancreatic relationship in patients with pancreatopathies and other non-pancreatic digestive alterations, by means of serum pancreolauril (sPL) and oral glucose tolerance tests (OGTT). Glycemia and insulin, basal and at 30, 60 and 120 minutes; amylase and lipase; and the HOMA index (homeostatic model) were determined in serum. Thirty-two patients were evaluated: normal OGTT (n=11, control group) and pathologic OGTT (n=21). From the latter group, a subgroup (n=11) with a diagnosis of chronic pancreatitis (CP) was studied. Patients with pathologic OGTT in relation with normal OGTT presented a significant increase of glycemia at the four periods of time and of insulin at 120 minutes (P < 0.05), and a significant decrease of sPL (P < 0.05). In patients with CP, men were more than women, and all of them presented a pathologic OGTT and the sPL was significantly lower (P < 0.001). By the biochemical tests used, pancreas functionality corresponds with a close relationship between exocrine and endocrine pancreas. Thus, we suggest the use of the sPL test as a helpful tool for the diagnosis of CP.

  11. Test Systems to Study the Structure and Function of Uncoupling Protein 1: A Critical Overview

    PubMed Central

    Hirschberg, Verena; Fromme, Tobias; Klingenspor, Martin

    2011-01-01

    The discovery of active brown adipose tissue (BAT) in healthy adult humans has renewed interest in the biology of this organ. BAT is capable of distributing nutrient energy in the form of heat allowing small mammals to efficiently defend their body temperature when acutely exposed to the cold. On the other hand BAT might be a target for the treatment of obesity and related diseases, as its pharmacological activation could allow release of excess energy stored in white adipose tissue depots. Energy dissipation in BAT depends on the activity of uncoupling protein 1 (UCP1), therefore a BAT-based obesity therapy requires a detailed understanding of structure and function of UCP1. Although UCP1 has been in the focus of research since its discovery, central questions concerning its mechanistic function and regulation are not yet resolved. They have been addressed in native mitochondria but also in several test systems, which are generally used to lower inter-experimental variability and to simplify analysis conditions. Different test systems have contributed to our current knowledge about UCP1 but of course all of them have certain limitations. We here provide an overview about research on UCP1 structure and function in test systems. So far, these have nearly exclusively been employed to study rodent and not human UCP1. Considering that the amino acid sequence of mouse and human UCP1 is only 79% identical, it will be essential to test whether the human version has a similarly high catalytic activity, allowing a relevant amount of energy dissipation in human BAT. Besides the issue of comparable mechanistic function a sufficiently high expression level of human UCP1 is a further prerequisite for anti-obesity therapeutic potential. Treatments which induce BAT hyperplasia and UCP1 expression in humans might therefore be equally important to discover as mere activators of the thermogenic process. PMID:22654819

  12. Tests of potential functional barriers for laminated multilayer food packages. Part I: Low molecular weight permeants.

    PubMed

    Simal-Gándara, J; Sarria-Vidal, M; Koorevaar, A; Rijk, R

    2000-08-01

    The advent of the functional barrier concept in food packaging has brought with it a requirement for fast tests of permeation through potential barrier materials. In such tests it would be convenient for both foodstuffs and materials below the functional barrier (sub-barrier materials) to be represented by standard simulants. By means of inverse gas chromatography, liquid paraffin spiked with appropriate permeants was considered as a potential simulant of sub-barrier materials based on polypropylene (PP) or similar polyolefins. Experiments were performed to characterize the kinetics of the permeation of low molecular weight model permeants (octene, toluene and isopropanol) from liquid paraffin, through a surrogate potential functional barrier (25 microns-thick oriented PP) into the food stimulants olive oil and 3% (w/v) acetic acid. These permeation results were interpreted in terms of three permeation kinetic models regarding the solubility of a particular model permeant in the post-barrier medium (i.e. the food simulant). The results obtained justify the development and evaluation of liquid sub-barrier simulants that would allow flexible yet rigorous testing of new laminated multilayer packaging materials.

  13. Novel scanning electron microscope bulge test technique integrated with loading function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Chuanwei; Xie, Huimin, E-mail: liuzw@bit.edu.cn, E-mail: xiehm@mail.tsinghua.edu.cn; Liu, Zhanwei, E-mail: liuzw@bit.edu.cn, E-mail: xiehm@mail.tsinghua.edu.cn

    2014-10-15

    Membranes and film-on-substrate structures are critical elements for some devices in electronics industry and for Micro Electro Mechanical Systems devices. These structures are normally at the scale of micrometer or even nanometer. Thus, the measurement for the mechanical property of these membranes poses a challenge over the conventional measurements at macro-scales. In this study, a novel bulge test method is presented for the evaluation of mechanical property of micro thin membranes. Three aspects are discussed in the study: (a) A novel bulge test with a Scanning Electron Microscope system realizing the function of loading and measuring simultaneously; (b) a simplifiedmore » Digital Image Correlation method for a height measurement; and (c) an imaging distortion correction by the introduction of a scanning Moiré method. Combined with the above techniques, biaxial modulus as well as Young's modulus of the polyimide film can be determined. Besides, a standard tensile test is conducted as an auxiliary experiment to validate the feasibility of the proposed method.« less

  14. NSTAR Ion Thruster and Breadboard Power Processor Functional Integration Test Results

    NASA Technical Reports Server (NTRS)

    Hamley, John A.; Pinero, Luis R.; Rawlin, Vincent K.; Miller, John R.; Myers, Roger M.; Bowers, Glen E.

    1996-01-01

    A 2.3 kW Breadboard Power Processing Unit (BBPPU) was developed as part of the NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) Program. The NSTAR program will deliver an electric propulsion system based on a 30 cm xenon ion thruster to the New Millennium (NM) program for use as the primary propulsion system for the initial NM flight. The final development test for the BBPPU, the Functional Integration Test, was carried out to demonstrate all aspects of BBPPU operation with an Engineering Model Thruster. Test objectives included: (1) demonstration and validation of automated thruster start procedures, (2) demonstration of stable closed loop control of the thruster beam current, (3) successful response and recovery to thruster faults, and (4) successful safing of the system during simulated spacecraft faults. These objectives were met over the specified 80-120 VDC input voltage range and 0.5-2.3 output power capability of the BBPPU. Two minor anomalies were noted in discharge and neutralizer keeper current. These anomalies did not affect the stability of the system and were successfully corrected.

  15. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  16. Application of force-velocity cycle ergometer test and vertical jump tests in the functional assessment of karate competitor.

    PubMed

    Ravier, G; Grappe, F; Rouillon, J D

    2004-12-01

    The aim of this study was to analyze the links between tests performances (vertical jump and force-velocity sprint on cycle ergometer) and 2 different karate level groups in order to propose a test battery adjusted to karate. Twenty-two karate competitors (10 national junior team (IJ) and 12 national competition level (NL)) performed 4 maximal squat jumps (SJ), 4 maximal counter movement jumps (CMJ) on an ergojump and 3 8-s sprints on a friction braked cycle ergometer (friction loads of 0.5, 0.7, 0.9 N x kg(-1)). The maximal theoretical force (F(0)) and velocity (V(0)), the maximal power output (P(max)) and the optimal pedalling velocity (V(opt)) were derived from both the force -- velocity and the power -- velocity relationships plotted from all the 3 friction loads data. V(0), F(0), V(opt), P(max) and the best SJ and CMJ, were compared between IJ and NL groups. The IJ group was characterised by significantly higher values of V(0) (+13%) and SJ (+14.3%) compared to NL group, whereas no significant difference was observed between groups for F(0). Thus, karate performance would depend on maximal velocity and explosive strength. In addition, V(opt) was significantly higher in IJ group compared to NL group (135.4 rpm vs 119.2 rpm, p<0.001). Although based upon indirect evidence, these results accounted for mechanical functional capabilities of experts which could be particularly valuable when monitoring training of karate competitor. A force-velocity and a vertical jump tests may be applied in the functional assessment of karate competitor.

  17. A simple attention test in the acute phase of a major depressive episode is predictive of later functional remission.

    PubMed

    Cléry-Melin, Marie-Laure; Gorwood, Philip

    2017-02-01

    Functional recovery after a major depressive episode (MDE) requires both clinical remission and preservation of cognitive skills. As attentional deficit may persist after remission, leading to functional impairment, its role as a prognosis marker needs to be considered. Five hundred eight depressed outpatients (DSM-IV) were assessed at baseline for clinical symptoms (QIDS-SR), social functioning (Sheehan Disability Scale, SDS) and attention through the d2 test of attention and the trail making test, simple tests, respectively, requiring to quote or to interconnect relevant items. All patients were treated by agomelatine, and examined 6 to 8 weeks after baseline to assess clinical remission (QIDS-SR ≤ 5) and/or functional remission (SDS ≤ 6). At follow up, 154 patients (31%) were in clinical and functional remission. Shorter cumulative duration of prior depression, shorter present MDE, and two parameters of the d2 test of attention were predictive of such positive outcome, the number of omission mistakes (F1) being the only one still significantly predictive (P < .05) with a multivariate approach. F1 was unchanged after remission, patients with less than 11 mistakes had a 2.27 times increased chance to reach full remission, and a dose-response relationship was observed, with a regular increase of positive outcome for less mistakes. The number of omission mistakes (F1) of the d2 test of attention was a stable marker, being predictive of, and with a dose-effect for, clinical plus functional remission. It may constitute a specific marker of attentional deficit, involved in the resilience process that enables individuals to develop more adequate strategies to cope with everyday functional activities. © 2016 Wiley Periodicals, Inc.

  18. A test of multiple hypotheses for the function of call sharing in female budgerigars, Melopsittacus undulatus

    PubMed Central

    Young, Anna M.; Cordier, Breanne; Mundry, Roger; Wright, Timothy F.

    2014-01-01

    In many social species group, members share acoustically similar calls. Functional hypotheses have been proposed for call sharing, but previous studies have been limited by an inability to distinguish among these hypotheses. We examined the function of vocal sharing in female budgerigars with a two-part experimental design that allowed us to distinguish between two functional hypotheses. The social association hypothesis proposes that shared calls help animals mediate affiliative and aggressive interactions, while the password hypothesis proposes that shared calls allow animals to distinguish group identity and exclude nonmembers. We also tested the labeling hypothesis, a mechanistic explanation which proposes that shared calls are used to address specific individuals within the sender–receiver relationship. We tested the social association hypothesis by creating four–member flocks of unfamiliar female budgerigars (Melopsittacus undulatus) and then monitoring the birds’ calls, social behaviors, and stress levels via fecal glucocorticoid metabolites. We tested the password hypothesis by moving immigrants into established social groups. To test the labeling hypothesis, we conducted additional recording sessions in which individuals were paired with different group members. The social association hypothesis was supported by the development of multiple shared call types in each cage and a correlation between the number of shared call types and the number of aggressive interactions between pairs of birds. We also found support for calls serving as a labeling mechanism using discriminant function analysis with a permutation procedure. Our results did not support the password hypothesis, as there was no difference in stress or directed behaviors between immigrant and control birds. PMID:24860236

  19. Cardiopulmonary exercise testing and second-line pulmonary function tests to detect obstructive pattern in symptomatic smokers with borderline spirometry.

    PubMed

    Di Marco, Fabiano; Terraneo, Silvia; Job, Sara; Rinaldo, Rocco Francesco; Sferrazza Papa, Giuseppe Francesco; Roggi, Maria Adelaide; Santus, Pierachille; Centanni, Stefano

    2017-06-01

    The need for additional research on symptomatic smokers with normal spirometry has been recently emphasized. Albeit not meeting criteria for Chronic obstructive pulmonary disease (COPD) diagnosis, symptomatic smokers may experience activity limitation, evidence of airway disease, and exacerbations. We, therefore, evaluated whether symptomatic smokers with borderline spirometry (post-bronchodilator FEV 1 /FVC ratio between 5th to 20th percentile of predicted values) have pulmonary function abnormalities at rest and ventilatory constraints during exercise. 48 subjects (aged 60 ± 8 years, mean ± SD, 73% males, 16 healthy, and 17 symptomatic smokers) underwent cardiopulmonary exercise testing (CPET), body plethysmography, nitrogen single-breath washout test (N 2 SBW), lung diffusion for carbon monoxide (DLCO), and forced oscillation technique (FOT). Compared to healthy subjects, symptomatic smokers showed: 1) reduced breathing reserve (36 ± 17 vs. 49 ± 12%, P = 0.050); 2) exercise induced dynamic hyperinflation (-0.20 ± 0.17 vs. -0.03 ± 0.21 L, P = 0.043); 3) higher residual volume (158 ± 22 vs. 112 ± 22%, P < 0.001); 4) phase 3 slope at N 2 SBW (4.7 ± 2.1 vs. 1.4 ± 0.6%, P < 0.001); 5) no significant differences in DLCO and FOT results. In smokers with borderline spirometry, CPET and second-line pulmonary function tests may detect obstructive pattern. These subjects should be referred for second line testing, to obtain a diagnosis, or at least to clarify the mechanisms underlying symptoms. Whether the natural history of these patients is similar to COPD, and they deserve a similar therapeutic approach is worth investigating. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  1. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  2. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  3. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  4. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  5. [The informative value of the functional step test for the purpose of computed optical topography in the children presenting with the functional disorders of the musculoskeletal system].

    PubMed

    Trukhmanov, I M; Suslova, G A; Ponomarenko, G N

    This paper is devoted to the characteristic of the informative value of the functional step test with the application of the heel cushions in the children for the purpose of differential diagnostics of anatomic and functional differences in the length of the lower extremities. A total of 85 schoolchildren with different length of the lower extremities have been examined. The comparative evaluation of the results of clinical and instrumental examinations was undertaken. The data obtained with the help of the functional step test give evidence of its very high sensitivity, specificity, and clinical significant as a tool for the examination of the children with different length of the low extremities. It is concluded that the test is one of the most informative predictors of the effectiveness of rehabilitation in the children with different length of the lower extremities.

  6. Abnormal Liver Function Tests in an Anorexia Nervosa Patient and an Atypical Manifestation of Refeeding Syndrome.

    PubMed

    Vootla, Vamshidhar R; Daniel, Myrta

    2015-01-01

    Refeeding syndrome is defined as electrolyte and fluid abnormalities that occur in significantly malnourished patients when they are refed orally, enterally, or parenterally. The principal manifestations include hypophosphatemia, hypokalemia, vitamin deficiencies, volume overload and edema. This can affect multiple organ systems, such as the cardiovascular, pulmonary, or neurological systems, secondary to the above-mentioned abnormalities. Rarely, patients may develop gastrointestinal symptoms and show abnormal liver function test results. We report the case of a 52-year-old woman with anorexia nervosa who developed refeeding syndrome and simultaneous elevations of liver function test results, which normalized upon the resolution of the refeeding syndrome.

  7. Specialized sperm function tests in varicocele and the future of andrology laboratory

    PubMed Central

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele. PMID:26780873

  8. Specialized sperm function tests in varicocele and the future of andrology laboratory.

    PubMed

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele.

  9. Comparing usability testing outcomes and functions of six electronic nursing record systems.

    PubMed

    Cho, Insook; Kim, Eunman; Choi, Woan Heui; Staggers, Nancy

    2016-04-01

    This study examined the usability of six differing electronic nursing record (ENR) systems on the efficiency, proficiency and available functions for documenting nursing care and subsequently compared the results to nurses' perceived satisfaction from a previous study. The six hospitals had different ENR systems, all with narrative nursing notes in use for more than three years. Stratified by type of nursing unit, 54 staff nurses were digitally recorded during on-site usability testing by employing validated patient care scenarios and think-aloud protocols. The time to complete specific tasks was also measured. Qualitative performance data were converted into scores on efficiency (relevancy), proficiency (accuracy), and a competency index using scoring schemes described by McGuire and Babbott. Six nurse managers and the researchers completed assessments of available ENR functions and examined computerized nursing process components including the linkages among them. For the usability test, participants' mean efficiency score was 94.2% (95% CI, 91.4-96.9%). The mean proficiency was 60.6% (95% CI, 54.3-66.8%), and the mean competency index was 59.5% (95% CI, 52.9-66.0). Efficiency scores were significantly different across ENRs as was the time to complete tasks, ranging from 226.3 to 457.2s (χ(2)=12.3, P=0.031; χ(2)=11.2, P=0.048). No significant differences were seen for proficiency scores. The coverage of the various ENRs' nursing process ranged from 67% to 100%, but only two systems had complete integration of nursing components. Two systems with high efficiency and proficiency scores had much lower usability test scores and perceived user satisfaction along with more complex navigation patterns. In terms of system usability and functions, different levels of sophistication of and interaction performance with ENR systems exist in practice. This suggests that ENRs may have variable impacts on clinical outcomes and care quality. Future studies are needed to

  10. Validity and Responsiveness of the Two-Minute Walk Test for Measuring Functional Recovery After Total Knee Arthroplasty.

    PubMed

    Unnanuntana, Aasis; Ruangsomboon, Pakpoom; Keesukpunt, Worawut

    2018-06-01

    The 2-minute walk test (2mwt) is a performance-based test that evaluates functional recovery after total knee arthroplasty (TKA). This study evaluated its validity compared with the modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), modified Knee Score, Numerical Pain Rating Scale, and Timed Up and Go test, and its responsiveness in assessing functional recovery in TKA patients. This prospective cohort study included 162 patients undergoing primary TKA between 2013 and 2015. We used patient-reported outcome measures (modified WOMAC, OKS, modified Knee Score, Numerical Pain Rating Scale) and performance-based tests (2mwt and Timed Up and Go test) at baseline and 3, 6, and 12 months postoperatively. The construct validity of 2mwt was determined between the 2mwt distances walked and other outcome measurements. To assess responsiveness, effect size and standardized response mean were analyzed. Minimal clinically important difference of 2mwt at 12 months after TKA was also calculated. All outcome measurements improved significantly from baseline to 3, 6, and 12 months postoperatively. Bivariate analysis revealed mild to moderate associations between the 2mwt and modified WOMAC function subscales, and moderate to strong associations with OKS. Mild to moderate correlations were found for pain and stiffness between 2mwt and other outcome measurements. The effect size and standardized response mean at 12 months were large, with a minimal clinically important difference of 12.7 m. 2mwt is a validated performance-based test with responsiveness properties. Being simple and easy to perform, it can be used routinely in clinical practice to evaluate functional recovery after TKA. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Executive functions as endophenotypes in ADHD: evidence from the Cambridge Neuropsychological Test Battery (CANTAB).

    PubMed

    Gau, Susan Shur-Fen; Shang, Chi-Yung

    2010-07-01

    Little is known about executive functions among unaffected siblings of children with attention deficit/hyperactivity disorder (ADHD), and there is lack of such information from non-Western countries. We examined verbal and nonverbal executive functions in adolescents with ADHD, unaffected siblings and controls to test whether executive functions could be potential endophenotypes for ADHD. We assessed 279 adolescents (age range: 11-17 years) with a childhood diagnosis of DSM-IV ADHD, 136 biological siblings (108 unaffected, 79.4%), and 173 unaffected controls by using psychiatric interviews, the Wechsler Intelligence Scale for Children - 3rd edition (WISC-III), including digit spans, and the tasks involving executive functions of the Cambridge Neuropsychological Test Automated Battery (CANTAB): Intra-dimensional/Extra-dimensional Shifts (IED), Spatial Span (SSP), Spatial Working Memory (SWM), and Stockings of Cambridge (SOC). Compared with the controls, adolescents with ADHD and unaffected siblings had a significantly shorter backward digit span, more extra-dimensional shift errors in the IED, shorter spatial span length in the SSP, more total errors and poorer strategy use in the SWM, and fewer problems solved in the minimum number of moves and shorter initial thinking time in the SOC. The magnitudes of the differences in the SWM and SOC increased with increased task difficulties. In general, neither persistent ADHD nor comorbidity was associated with increased deficits in executive functions among adolescents with ADHD. The lack of much difference in executive dysfunctions between unaffected siblings and ADHD adolescents suggests that executive dysfunctions may be useful cognitive endophenotypes for ADHD genetic studies.

  12. Poor Vision, Functioning, and Depressive Symptoms: A Test of the Activity Restriction Model

    ERIC Educational Resources Information Center

    Bookwala, Jamila; Lawson, Brendan

    2011-01-01

    Purpose: This study tested the applicability of the activity restriction model of depressed affect to the context of poor vision in late life. This model hypothesizes that late-life stressors contribute to poorer mental health not only directly but also indirectly by restricting routine everyday functioning. Method: We used data from a national…

  13. Characterization of thyroid function and antithyroid antibody tests among Saudis

    PubMed Central

    Jammah, Anwar A.; Alshehri, Anwar S.; Alrakhis, Afaf A.; Alhedaithy, Asma S.; Almadhi, Asma M.; Alkwai, Hala M.; Alhamad, Maram M.; Alzahrani, Saad H.

    2015-01-01

    Objective: To determine the reference intervals for thyroid function tests and the prevalence of thyroid autoimmunity in the Saudi population. Methods: A cross-sectional prospective study was conducted in King Khalid University Hospital, Riyadh, Saudi Arabia from January to June 2013. History and physical examination were obtained. Thyroid-stimulating hormone (TSH), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by Electro-chemiluminescence Immunoassay system-assay. Anti-thyroperoxidase, and anti-thyroglobulin antibodies were measured using enzyme-linked immunosorbent-assay. Subjects with previous or a family history of thyroid disorders, those taking medications affecting thyroid function, pregnant or lactating women, and those with goiter were excluded. Individuals with positive antibodies were excluded from the final analysis of the TSH reference range, but were used to determine the prevalence of thyroid autoimmunity. Results: Out of 337 Saudi subjects initially screened, 132 (aged 13-60 years) were candidates for reference calculation, the mean±standard deviation, and (2.5th-97.5th) percentile of TSH (mIU/L) was 1.96±0.9 (0.59-4.37), for FT4 (pmol/L) was 15.47±1.83 (12.04-19.13), and for FT3 (pmol/L) was 5.22±0.7 (4.07-6.76). The TSH was higher in the antibodies positive group (2.5±1.17 mIU/L) compared with the negative one (1.96±0.9 mIU/L) (p<0.05). Finally, 26% of subjects were tested positive for antithyroid antibodies. Conclusion: The TSH reference range was similar to laboratory references. Thyroid antibodies were prevalent in Saudis, necessitating further work in larger scale studies. PMID:25987111

  14. Characterization of thyroid function and antithyroid antibody tests among Saudis.

    PubMed

    Jammah, Anwar A; Alshehri, Anwar S; Alrakhis, Afaf A; Alhedaithy, Asma S; Almadhi, Asma M; Alkwai, Hala M; Alhamad, Maram M; Alzahrani, Saad H

    2015-06-01

    To determine the reference intervals for thyroid function tests and the prevalence of thyroid autoimmunity in the Saudi population.   A cross-sectional prospective study was conducted in King Khalid University Hospital, Riyadh, Saudi Arabia from January to June 2013. History and physical examination were obtained. Thyroid-stimulating hormone (TSH), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by Electro-chemiluminescence Immunoassay system-assay. Anti-thyroperoxidase, and anti-thyroglobulin antibodies were measured using enzyme-linked immunosorbent-assay. Subjects with previous or a family history of thyroid disorders, those taking medications affecting thyroid function, pregnant or lactating women, and those with goiter were excluded. Individuals with positive antibodies were excluded from the final analysis of the TSH reference range, but were used to determine the prevalence of thyroid autoimmunity.   Out of 337 Saudi subjects initially screened, 132 (aged 13-60 years) were candidates for reference calculation, the mean±standard deviation, and (2.5th-97.5th) percentile of TSH (mIU/L) was 1.96±0.9 (0.59-4.37), for FT4 (pmol/L) was 15.47±1.83 (12.04-19.13), and for FT3 (pmol/L) was 5.22±0.7 (4.07-6.76). The TSH was higher in the antibodies positive group (2.5±1.17 mIU/L) compared with the negative one (1.96±0.9 mIU/L) (p less than 0.05). Finally, 26% of subjects were tested positive for antithyroid antibodies.   The TSH reference range was similar to laboratory references. Thyroid antibodies were prevalent in Saudis, necessitating further work in larger scale studies.

  15. Differential Item Functioning Analysis of High-Stakes Test in Terms of Gender: A Rasch Model Approach

    ERIC Educational Resources Information Center

    Alavi, Seyed Mohammad; Bordbar, Soodeh

    2017-01-01

    Differential Item Functioning (DIF) analysis is a key element in evaluating educational test fairness and validity. One of the frequently cited sources of construct-irrelevant variance is gender which has an important role in the university entrance exam; therefore, it causes bias and consequently undermines test validity. The present study aims…

  16. Lanthanide-functionalized silver nanoparticles for detection of an anthrax biomarker and test paper fabrication

    NASA Astrophysics Data System (ADS)

    Tan, Hongliang; Li, Qian; Ma, Chanjiao; Song, Yonghai; Xu, Fugang; Chen, Shouhui; Wang, Li

    2014-01-01

    It is highly desirable to develop a simple and sensitive analytical method for detection of anthrax biomarker (dipicolinic acid, DPA) because of its dangerous nature. In this work, we developed a fluorescent sensor for DPA detection based on terbium ion-functionalized silver nanoparticles with an average size of 6.7 nm (AgNPs-Tb3+). The fluorescent intensity of Tb-DPA complex on the surface of AgNPs was two times higher than that of Tb-DPA complex alone in a solution phase due to the metal-enhanced fluorescence (MEF) effect of AgNPs. The proposed fluorescent sensor exhibits excellent selectivity and high sensitivity for DPA. Importantly, a test paper for DPA detection was fabricated for the first time by the integration of AgNPs-Tb3+ onto the nitrocellulose membrane. Owing to the MEF effect of AgNPs, the lowest detectable concentration of the test paper-integrated AgNPs-Tb3+ for DPA by naked eyes is 10 times lower than that of the test paper-integrated Tb3+ alone. We believe that the presented strategy may open up new avenues to the development of portable and robust-sensing platforms based on functional hybrid materials.

  17. The video ocular counter-roll (vOCR): a clinical test to detect loss of otolith-ocular function

    PubMed Central

    Otero-Millan, Jorge; Treviño, Carolina; Winnick, Ariel; Zee, David S.; Carey, John P.; Kheradmand, Amir

    2017-01-01

    Conclusion vOCR can detect loss of otolith-ocular function without specifying the side of vestibular loss. Since vOCR is measured with a simple head tilt maneuver, it can be potentially used as a bedside clinical test in combination with video head impulse test. Objective Video-oculography (VOG) goggles are being integrated into the bedside assessment of patients with vestibular disorders. Lacking, however, is a method to evaluate otolith function. This study validated a VOG test for loss of otolith function. Methods VOG was used to measure ocular counter-roll (vOCR) in 12 healthy controls, 14 patients with unilateral vestibular loss (UVL), and six patients with bilateral vestibular loss (BVL) with a static lateral head tilt of 30°. The results were compared with vestibular evoked myogenic potentials (VEMP), a widely-used laboratory test of otolith function. Results The average vOCR for healthy controls (4.6°) was significantly different from UVL (2.7°) and BVL (1.6°) patients (p < 0.0001). The vOCR and VEMP measurements were correlated across subjects, especially the click and tap oVEMPs (click oVEMP R = 0.45, tap oVEMP R = 0.51; p < 0.0003). The receiver operator characteristic (ROC) analysis showed that vOCR and VEMPs detected loss of otolith function equally well. The best threshold for vOCR to detect vestibular loss was at 3°. The vOCR values from the side of vestibular loss and the healthy side were not different in UVL patients (2.53° vs 2.8°; p = 0.59). PMID:28084887

  18. Health outcomes following liver function testing in primary care: a retrospective cohort study.

    PubMed

    McLernon, David J; Donnan, Peter T; Ryder, Stephen; Roderick, Paul; Sullivan, Frank M; Rosenberg, William; Dillon, John F

    2009-08-01

    patients who present with abnormal liver function tests (LFTs) in primary care and no obvious symptoms can be difficult to manage. The objective is to follow-up a cohort of liver function tested patients to determine their outcome. This population-based retrospective cohort study was conducted in Tayside, Scotland, from 1989 to 2003. Subjects were patients with no clinically obvious liver disease at initial liver function testing in primary care. Main outcomes were diagnosed liver disease and mortality. Record linkage of databases ascertained risk factors and outcomes. Measures of performance were calculated and Weibull regression analysis from initial LFT date was performed on all outcomes by level of abnormality. In total, 95 977 patients had 364 194 incident initial LFTs, with median follow-up 3.7 years. A total of 21.7% had at least one abnormal LFT and 1108 (1.15%) developed liver disease. Elevated transaminase was strongly associated with diagnosed liver disease, hazard ratio (HR) = 4.23 (95% confidence interval 3.55, 5.04) for mild levels and HR = 12.67 (95% CI 9.74, 16.47) for severe levels versus normal. For gamma-glutamyl transferase, these hazards were 2.54 (95% CI 2.17, 2.96) and 13.44 (95% CI 10.71, 16.87), respectively. Low albumin was strongly associated with all-cause mortality, HR = 2.65 (95% CI 2.47, 2.85) for mild levels and HR = 4.99 (95% CI 4.26, 5.84) for severe levels. Sensitivity for predicting events over 5 years was low and specificity high. All LFTs were predictive markers for liver disease as well as general ill health, although sensitivity was poor. Most patients with abnormal LFTs had no later formal diagnosis of liver disease within the study period. The time taken to develop liver disease in these patients provides opportunity to intervene.

  19. High-Resolution Time-Frequency Spectrum-Based Lung Function Test from a Smartphone Microphone

    PubMed Central

    Thap, Tharoeun; Chung, Heewon; Jeong, Changwon; Hwang, Ki-Eun; Kim, Hak-Ryul; Yoon, Kwon-Ha; Lee, Jinseok

    2016-01-01

    In this paper, a smartphone-based lung function test, developed to estimate lung function parameters using a high-resolution time-frequency spectrum from a smartphone built-in microphone is presented. A method of estimation of the forced expiratory volume in 1 s divided by forced vital capacity (FEV1/FVC) based on the variable frequency complex demodulation method (VFCDM) is first proposed. We evaluated our proposed method on 26 subjects, including 13 healthy subjects and 13 chronic obstructive pulmonary disease (COPD) patients, by comparing with the parameters clinically obtained from pulmonary function tests (PFTs). For the healthy subjects, we found that an absolute error (AE) and a root mean squared error (RMSE) of the FEV1/FVC ratio were 4.49% ± 3.38% and 5.54%, respectively. For the COPD patients, we found that AE and RMSE from COPD patients were 10.30% ± 10.59% and 14.48%, respectively. For both groups, we compared the results using the continuous wavelet transform (CWT) and short-time Fourier transform (STFT), and found that VFCDM was superior to CWT and STFT. Further, to estimate other parameters, including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and peak expiratory flow (PEF), regression analysis was conducted to establish a linear transformation. However, the parameters FVC, FEV1, and PEF had correlation factor r values of 0.323, 0.275, and −0.257, respectively, while FEV1/FVC had an r value of 0.814. The results obtained suggest that only the FEV1/FVC ratio can be accurately estimated from a smartphone built-in microphone. The other parameters, including FVC, FEV1, and PEF, were subjective and dependent on the subject’s familiarization with the test and performance of forced exhalation toward the microphone. PMID:27548164

  20. Sport-specific endurance plank test for evaluation of global core muscle function.

    PubMed

    Tong, Tom K; Wu, Shing; Nie, Jinlei

    2014-02-01

    To examine the validity and reliability of a sports-specific endurance plank test for the evaluation of global core muscle function. Repeated-measures study. Laboratory environment. Twenty-eight male and eight female young athletes. Surface electromyography (sEMG) of selected trunk flexors and extensors, and an intervention of pre-fatigue core workout were applied for test validation. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and the measurement bias ratio */÷ ratio limits of agreement (LOA) were calculated to assess reliability and measurement error. Test validity was shown by the sEMG of selected core muscles, which indicated >50% increase in muscle activation during the test; and the definite discrimination of the ∼30% reduction in global core muscle endurance subsequent to a pre-fatigue core workout. For test-retest reliability, when the first attempt of three repeated trials was considered as familiarisation, the ICC was 0.99 (95% CI: 0.98-0.99), CV was 2.0 ± 1.56% and the measurement bias ratio */÷ ratio LOA was 0.99 */÷ 1.07. The findings suggest that the sport-specific endurance plank test is a valid, reliable and practical method for assessing global core muscle endurance in athletes given that at least one familiarisation trial takes place prior to measurement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. PROSPECTIVE FUNCTIONAL PERFORMANCE TESTING AND RELATIONSHIP TO LOWER EXTREMITY INJURY INCIDENCE IN ADOLESCENT SPORTS PARTICIPANTS

    PubMed Central

    DePhillipo, Nick; Kimura, Iris; Kocher, Morgan; Hetzler, Ronald

    2017-01-01

    Background Due to the high number of adolescent athletes and subsequent lower extremity injuries, improvements of injury prevention strategies with emphasis on clinic-based and practical assessments are warranted. Purpose The purpose of this study was to prospectively investigate if a battery of functional performance tests (FPT) could be used as a preseason-screening tool to identify adolescent athletes at risk for sports-related acute lower extremity injury via comparison of injured and uninjured subjects. Methods One hundred adolescent volleyball, basketball and soccer athletes (female, n=62; male, n=38; mean age = 14.4 ± 1.6) participated. The FPT assessment included: triple hop for distance, star excursion balance test, double leg lowering maneuver, drop jump video test, and multi-stage fitness test. Composite scores were calculated using a derived equation. Subjects were monitored throughout their designated sport season(s), which consisted of a six-month surveillance period. The schools certified athletic trainer (ATC) recorded all injuries. Subjects were categorized into groups according to sex and injury incidence (acute lower extremity injury vs. uninjured) for analysis. Results Mean FPT composite scores were significantly lower for the injured compared to the uninjured groups in both sexes (males: 19.06 ± 3.59 vs. 21.90 ± 2.44; females: 19.48 ± 3.35 vs. 22.10 ± 3.06 injured and uninjured, respectively)(p < .05). The receiver-operator characteristic analysis determined the cut-off score at ≤ 20 for both genders (sensitivity=.71, specificity=.81, for males; sensitivity=.67, specificity=.69, for females)(p<.05) for acute noncontact lower extremity injuries. Significant positive correlations were found between the FPT composite score and the multi-stage fitness test in male subjects (r=.474, p=.003), suggesting a relationship between functional performance, aerobic capacity, and potential injury risk. Conclusion A

  2. 34 CFR 462.42 - How are tests used to place students at an NRS educational functioning level?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... functioning level. (b) A local eligible provider must use the results of the post-test described in § 462.41(c... 34 Education 3 2011-07-01 2011-07-01 false How are tests used to place students at an NRS... Eligible Providers Follow When Measuring Educational Gain? § 462.42 How are tests used to place students at...

  3. 34 CFR 462.42 - How are tests used to place students at an NRS educational functioning level?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... functioning level. (b) A local eligible provider must use the results of the post-test described in § 462.41(c... 34 Education 3 2013-07-01 2013-07-01 false How are tests used to place students at an NRS... Eligible Providers Follow When Measuring Educational Gain? § 462.42 How are tests used to place students at...

  4. 34 CFR 462.42 - How are tests used to place students at an NRS educational functioning level?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... functioning level. (b) A local eligible provider must use the results of the post-test described in § 462.41(c... 34 Education 3 2014-07-01 2014-07-01 false How are tests used to place students at an NRS... Eligible Providers Follow When Measuring Educational Gain? § 462.42 How are tests used to place students at...

  5. 34 CFR 462.42 - How are tests used to place students at an NRS educational functioning level?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... functioning level. (b) A local eligible provider must use the results of the post-test described in § 462.41(c... 34 Education 3 2010-07-01 2010-07-01 false How are tests used to place students at an NRS... Eligible Providers Follow When Measuring Educational Gain? § 462.42 How are tests used to place students at...

  6. 34 CFR 462.42 - How are tests used to place students at an NRS educational functioning level?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... functioning level. (b) A local eligible provider must use the results of the post-test described in § 462.41(c... 34 Education 3 2012-07-01 2012-07-01 false How are tests used to place students at an NRS... Eligible Providers Follow When Measuring Educational Gain? § 462.42 How are tests used to place students at...

  7. Prognostic Value of Metabolic Liver Function Tests: a Study on 711 Cirrhotic Patients.

    PubMed

    Lebossé, Fanny; Guillaud, Olivier; Forestier, Julien; Ecochard, Marie; Boillot, Olivier; Roman, Sabine; Mion, François; Dumortier, Jérôme

    2016-09-01

    The prognosis of cirrhotic patients is usually assessed by Child-Pugh and MELD scores. Metabolic liver function tests such as aminopyrine breath test (ABT) and indocyanine green clearance (IGC) have been shown to reveal hepatocellular dysfunction. The aim of this retrospective study was to compare the prognostic value of the MELD score, Child-Pugh score, ABT and IGC in a large cohort of cirrhotic patients. Between January 1996 and June 2008, 711 cirrhotic patients were included and the primary endpoint was survival without LT. The ROC curves with c-statistics, correlation coefficient and survival were calculated. Metabolic function tests and scores were strongly correlated. At the time of evaluation, 111 patients had died and 520 had received a transplant. Prognostic ability (estimated by the AUROC curve) to predict survival without LT at 6 months was 0.662, 0.691, 0.738 and 0.715 for ABT, IGC, Child-Pugh score and MELD score, respectively. Similarly, at 1 year, AUROC was 0.738 for Child-Pugh score, 0.716 for MELD score, 0.693 for IGC clearance and 0.651 for ABT. Our results strongly confirm that IGC and ABT have a high prognostic value in cirrhotic patients, similar to Child-Pugh and MELD scores. They could be developed to routinely evaluate the prognosis of patients in addition to clinical and biochemical data.

  8. Accelerated Testing and Modeling of Potential-Induced Degradation as a Function of Temperature and Relative Humidity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacke, Peter; Spataru, Sergiu; Terwilliger, Kent

    2015-06-14

    An acceleration model based on the Peck equation was applied to power performance of crystalline silicon cell modules as a function of time and of temperature and humidity, the two main environmental stress factors that promote potential-induced degradation. This model was derived from module power degradation data obtained semi-continuously and statistically by in-situ dark current-voltage measurements in an environmental chamber. The modeling enables prediction of degradation rates and times as functions of temperature and humidity. Power degradation could be modeled linearly as a function of time to the second power; additionally, we found that coulombs transferred from the active cellmore » circuit to ground during the stress test is approximately linear with time. Therefore, the power loss could be linearized as a function of coulombs squared. With this result, we observed that when the module face was completely grounded with a condensed phase conductor, leakage current exceeded the anticipated corresponding degradation rate relative to the other tests performed in damp heat.« less

  9. An investigation of retronasal testing of olfactory function in a Turkish population

    PubMed Central

    Salihoglu, Murat; Altundag, Aytug; Cayonu, Melih; Tekeli, Hakan

    2014-01-01

    Background The aim of this study was: (1) to perform a preliminary study for the validation of “retronasal olfactory testing” in the Turkish population to find the best way to evaluate smell and taste disorders in Turkey; (2) to determine if cultural differences make application of the test more difficult; and (3) to determine the flavors that participants had not yet tasted by using the survey method. Material/Methods The study included 330 volunteers. Orthonasal olfactory function was assessed psycho-physically using the “Sniffin’ Sticks” olfactory test. Retronasal olfaction was assessed using a collection of 20 available food powders applied to the oral cavity. Also, all participants filled in a questionnaire of 50 items about the flavors they had not tasted before. Results The mean age of the participants was 26±7.3 years. Participants were divided into 3 groups according to the “Sniffin’ Sticks” test results: anosmia, hyposmia, and normosmia groups. Differences in retronasal olfaction scores were significant among the 3 groups. Conclusions The retronasal olfactory test appeared to perform well, but modifications of odorized powders or granules and distracters used in the retronasal olfactory test, taking into account Turkish cultural differences, is likely to improve its performance. PMID:24704823

  10. Failure on the Foam Eyes Closed Test of Standing Balance Associated With Reduced Semicircular Canal Function in Healthy Older Adults.

    PubMed

    Anson, Eric; Bigelow, Robin T; Studenski, Stephanie; Deshpande, Nandini; Agrawal, Yuri

    2018-06-11

    Standing on foam with eyes closed (FOEC) has been characterized as a measure of vestibular function; however, the relative contribution of vestibular function and proprioceptive function to the FOEC test has not been well described. In this study, the authors investigate the relationship between peripheral sensory systems (vestibular and proprioception) and performance on the FOEC test in a cohort of healthy adults. A total of 563 community-dwelling healthy adults (mean age, 72.7 [SD, 12.6] years; range, 27 to 93 years) participating in the Baltimore Longitudinal Study of Aging were tested. Proprioceptive threshold (PROP) was evaluated with passive motion detection at the right ankle. Vestibulo-ocular reflex (VOR) gain was measured using video head impulses. Otolith function was measured with cervical and ocular vestibular-evoked myogenic potentials. Participants stood on FOEC for 40 sec while wearing BalanSens (BioSensics, LLC, Watertown, MA) to quantify center of mass sway area. A mixed-model multiple logistic regression was used to examine the odds of passing the FOEC test based on PROP, VOR, cervical vestibular-evoked myogenic potential, and ocular vestibular-evoked myogenic potential function in a multisensory model while controlling for age and gender. The odds of passing the FOEC test decreased by 15% (p < 0.001) for each year of increasing age and by 8% with every 0.1 reduction in VOR gain (p = 0.025). Neither PROP nor otolith function was significantly associated with passing the FOEC test. Failure to maintain balance during FOEC may serve as a proxy for rotational vestibular contributions to postural control. Semicircular canals are more sensitive to low-frequency motion than otoliths that may explain these relationships because standing sway is dominated by lower frequencies. Lower VOR gain and increased age independently decreased the odds of passing the test.

  11. ESTROGEN REPLACEMENT THERAPY INDUCES FUNCTIONAL ASYMMETRY ON AN ODOR MEMORY/DISCRIMINATION TEST

    PubMed Central

    Doty, Richard L.; Kisat, Mehreen; Tourbier, Isabelle

    2008-01-01

    The secondary afferents of the olfactory system largely project to the ipsilateral cortex without synapsing in the thalamus, making unilateral olfactory testing a useful probe of ipsilateral hemispheric activity. In light of evidence that lateralized performance on some perceptual tasks may be influenced by estrogen, we assessed left:right nostril differences in two measures of olfactory function in 14 post-menopausal women receiving estrogen replacement therapy (ERT) and 48 post-menopausal women receiving no such therapy. Relative to women not taking ERT, those receiving ERT exhibited better performance in the left nostril and poorer performance in the right nostril on an odor memory/discrimination test. Similar laterality effects were not observed for an odor detection threshold test employing phenyl ethyl alcohol. These results suggest that estrogen influences the lateralization of an odor memory/discrimination task and that hormone replacement therapy in the menopause may be an excellent paradigm for understanding lateralizing effects of hormones on some sensory processes. PMID:18466883

  12. Functional Testing and Characterisation of ISFETs on Wafer Level by Means of a Micro-droplet Cell#

    PubMed Central

    Poghossian, Arshak; Schumacher, Kerstin; Kloock, Joachim P.; Rosenkranz, Christian; Schultze, Joachim W.; Müller-Veggian, Mattea; Schöning, Michael J.

    2006-01-01

    A wafer-level functionality testing and characterisation system for ISFETs (ion-sensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for non-functioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors.

  13. Abnormal Liver Function Tests in an Anorexia Nervosa Patient and an Atypical Manifestation of Refeeding Syndrome

    PubMed Central

    Vootla, Vamshidhar R.; Daniel, Myrta

    2015-01-01

    Refeeding syndrome is defined as electrolyte and fluid abnormalities that occur in significantly malnourished patients when they are refed orally, enterally, or parenterally. The principal manifestations include hypophosphatemia, hypokalemia, vitamin deficiencies, volume overload and edema. This can affect multiple organ systems, such as the cardiovascular, pulmonary, or neurological systems, secondary to the above-mentioned abnormalities. Rarely, patients may develop gastrointestinal symptoms and show abnormal liver function test results. We report the case of a 52-year-old woman with anorexia nervosa who developed refeeding syndrome and simultaneous elevations of liver function test results, which normalized upon the resolution of the refeeding syndrome. PMID:26351414

  14. Testing for the Gaussian nature of cosmological density perturbations through the three-point temperature correlation function

    NASA Technical Reports Server (NTRS)

    Luo, Xiaochun; Schramm, David N.

    1993-01-01

    One of the crucial aspects of density perturbations that are produced by the standard inflation scenario is that they are Gaussian where seeds produced by topological defects tend to be non-Gaussian. The three-point correlation function of the temperature anisotropy of the cosmic microwave background radiation (CBR) provides a sensitive test of this aspect of the primordial density field. In this paper, this function is calculated in the general context of various allowed non-Gaussian models. It is shown that the Cosmic Background Explorer and the forthcoming South Pole and balloon CBR anisotropy data may be able to provide a crucial test of the Gaussian nature of the perturbations.

  15. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    PubMed

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p < .001, and the content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p < .001, and captured 98.5% of consumers' seating-mobility goals. The cross-validation study identified new categories of seating-mobility goals for inclusion in FEW Version 2.0, and the content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  16. Functionally Enhanced Human Stem Cell Derived Hepatocytes in Galactosylated Cellulosic Sponges for Hepatotoxicity Testing.

    PubMed

    Tasnim, Farah; Toh, Yi-Chin; Qu, Yinghua; Li, Huan; Phan, Derek; Narmada, Balakrishnan C; Ananthanarayanan, Abhishek; Mittal, Nikhil; Meng, Ryan Q; Yu, Hanry

    2016-06-06

    Pluripotent stem cell derived hepatocyte-like cells (hPSC-HLCs) are an attractive alternative to primary human hepatocytes (PHHs) used in applications ranging from therapeutics to drug safety testing studies. It would be critical to improve and maintain mature hepatocyte functions of the hPSC-HLCs, especially for long-term studies. If 3D culture systems were to be used for such purposes, it would be important that the system can support formation and maintenance of optimal-sized spheroids for long periods of time, and can also be directly deployed in liver drug testing assays. We report the use of 3-dimensional (3D) cellulosic scaffold system for the culture of hPSC-HLCs. The scaffold has a macroporous network which helps to control the formation and maintenance of the spheroids for weeks. Our results show that culturing hPSC-HLCs in 3D cellulosic scaffolds increases functionality, as demonstrated by improved urea production and hepatic marker expression. In addition, hPSC-HLCs in the scaffolds exhibit a more mature phenotype, as shown by enhanced cytochrome P450 activity and induction. This enables the system to show a higher sensitivity to hepatotoxicants and a higher degree of similarity to PHHs when compared to conventional 2D systems. These results suggest that 3D cellulosic scaffolds are ideal for the long-term cultures needed to mature hPSC-HLCs. The mature hPSC-HLCs with improved cellular function can be continually maintained in the scaffolds and directly used for hepatotoxicity assays, making this system highly attractive for drug testing applications.

  17. Feasibility of a Novel Functional Sensibility Test as an Assisted Examination for Determining Precision Pinch Performance in Patients with Carpal Tunnel Syndrome

    PubMed Central

    Hsu, Hsiu-Yun; Kuo, Li-Chieh; Kuo, Yao-Lung; Chiu, Haw-Yen; Jou, I-Ming; Wu, Po-Ting; Su, Fong-Chin

    2013-01-01

    To understand the feasibility of a novel functional sensibility test for determining precision pinch performance in patients with carpal tunnel syndrome, this study investigates the validity, sensitivity and specificity of functional sensibility derived from a pinch-holding-up activity (PHUA) test. Participants include 70 clinically defined carpal tunnel syndrome (CTS) patients with 119 involved hands and 70 age- and gender-matched controls. To examine the discriminating ability of the functional sensibility test, the differences in the ability of pinch force adjustments to the inertial load of handling object between CTS and control subjects are analyzed. The results of functional sensibility are correlated with the severity of CTS to establish concurrent validity. The receiver operating characteristic (ROC) curve is constructed to demonstrate the accuracy of the proposed test. The functional sensibility score significantly discriminates the patients and control groups (respectively, 12.94±1.72 vs. 11.51±1.15N in peak pinch force (FPPeak), p<0.001; 2.92±0.41 vs. 2.52±0.24 in force ratio, p<0.001) and is moderately correlated (r = 0.42–0.54, p<0.001) with the results of traditional sensibility tests (touch-pressure threshold and two-point discrimination test). In addition, there is a statistical difference in the results of functional sensibility (p<0.001) among the subgroups of CTS severity based on electrophysiological study. The sensitivity and specificity are 0.79 and 0.76, respectively, for the functional sensibility test. The areas under the ROC curve are 0.85 and 0.80 for the force ratio and FPPeak, respectively. In conclusion, the functional sensibility test could be feasibly used as a clinical tool for determining both the sensibility and precision pinch performance of hands for the patients with CTS. PMID:23977209

  18. Item and scale differential functioning of the Mini-Mental State Exam assessed using the Differential Item and Test Functioning (DFIT) Framework.

    PubMed

    Morales, Leo S; Flowers, Claudia; Gutierrez, Peter; Kleinman, Marjorie; Teresi, Jeanne A

    2006-11-01

    To illustrate the application of the Differential Item and Test Functioning (DFIT) method using English and Spanish versions of the Mini-Mental State Examination (MMSE). Study participants were 65 years of age or older and lived in North Manhattan, New York. Of the 1578 study participants who were administered the MMSE 665 completed it in Spanish. : The MMSE contains 20 items that measure the degree of cognitive impairment in the areas of orientation, attention and calculation, registration, recall and language, as well as the ability to follow verbal and written commands. After assessing the dimensionality of the MMSE scale, item response theory person and item parameters were estimated separately for the English and Spanish sample using Samejima's 2-parameter graded response model. Then the DFIT framework was used to assess differential item functioning (DIF) and differential test functioning (DTF). Nine items were found to show DIF; these were items that ask the respondent to name the correct season, day of the month, city, state, and 2 nearby streets, recall 3 objects, repeat the phrase no ifs, no ands, no buts, follow the command, "close your eyes," and the command, "take the paper in your right hand, fold the paper in half with both hands, and put the paper down in your lap." At the scale level, however, the MMSE did not show differential functioning. Respondents to the English and Spanish versions of the MMSE are comparable on the basis of scale scores. However, assessments based on individual MMSE items may be misleading.

  19. Benchmarking density functional theory predictions of framework structures and properties in a chemically diverse test set of metal-organic frameworks

    DOE PAGES

    Nazarian, Dalar; Ganesh, P.; Sholl, David S.

    2015-09-30

    We compiled a test set of chemically and topologically diverse Metal–Organic Frameworks (MOFs) with high accuracy experimentally derived crystallographic structure data. The test set was used to benchmark the performance of Density Functional Theory (DFT) functionals (M06L, PBE, PW91, PBE-D2, PBE-D3, and vdW-DF2) for predicting lattice parameters, unit cell volume, bonded parameters and pore descriptors. On average PBE-D2, PBE-D3, and vdW-DF2 predict more accurate structures, but all functionals predicted pore diameters within 0.5 Å of the experimental diameter for every MOF in the test set. The test set was also used to assess the variance in performance of DFT functionalsmore » for elastic properties and atomic partial charges. The DFT predicted elastic properties such as minimum shear modulus and Young's modulus can differ by an average of 3 and 9 GPa for rigid MOFs such as those in the test set. Moreover, we calculated the partial charges by vdW-DF2 deviate the most from other functionals while there is no significant difference between the partial charges calculated by M06L, PBE, PW91, PBE-D2 and PBE-D3 for the MOFs in the test set. We find that while there are differences in the magnitude of the properties predicted by the various functionals, these discrepancies are small compared to the accuracy necessary for most practical applications.« less

  20. Screening Test Items for Differential Item Functioning

    ERIC Educational Resources Information Center

    Longford, Nicholas T.

    2014-01-01

    A method for medical screening is adapted to differential item functioning (DIF). Its essential elements are explicit declarations of the level of DIF that is acceptable and of the loss function that quantifies the consequences of the two kinds of inappropriate classification of an item. Instead of a single level and a single function, sets of…

  1. Influence of radiological emphysema on lung function test in idiopathic pulmonary fibrosis.

    PubMed

    Bodlet, Aline; Maury, Gisèle; Jamart, Jacques; Dahlqvist, Caroline

    2013-11-01

    Idiopathic pulmonary fibrosis (IPF) is one of the most frequent interstitial lung disease. Emphysema can be associated with IPF as described in the «Combined pulmonary fibrosis and emphysema» syndrome. The primary endpoint of this retrospective cohort study was to evaluate the impact of the association of IPF and emphysema on lung function tests parameters (FVC, TLC, FEV1, FEV1/FVC and DLCO). The secondary endpoint was to assess the impact of the associated radiological emphysema on lung function parameters used in the du Bois prognostic score recently developed by Ron du Bois et al. We retrospectively reviewed the medical files of 98 patients with lung fibrosis who were followed in our University Hospital with access to pharmacological studies and lung transplantation from 1981 to 2011. Fifty six patients were considered for analysis. The collected data included gender, age, smoking history and respiratory hospitalizations. We also analysed their pulmonary functional parameters along with radiological characteristics, in particular the presence of emphysema which was assessed on thoracic high resolution CT scan. The du Bois score was retrospectively calculated from these data. TLC and FVC at diagnosis were significantly higher in the IPF-E group compared to the IPF group (respectively 86.6 ± 17.2% pv versus 72.0 ± 15.0% pv; p: 0.004 and 86.8 ± 18.4% pv versus 72.6 ± 20.6% pv; p: 0.020). The [Formula: see text] used in the calculation of the du Bois prognostic score was significantly higher in the IPF-E group. By cons, [Formula: see text] was not statistically different between the two groups. Radiological emphysema associated with IPF had an impact on pulmonary function tests. Despite this difference, the du Bois score was not statistically different between these two groups. Nevertheless, after one year of follow up, the patients with emphysema were in a subclass with a lower mortality rate than those without emphysema. Copyright © 2013 Elsevier

  2. [Changes in respiratory function tests of healthy miners in accordance with length of service].

    PubMed

    Shishkin, G S; Ustiuzhaninova, N V; Krasulina, G P

    2010-01-01

    The study covered respiratory function tests in healthy miners with variable length of service. Findings are that the first year of mining is characterized by slower interchange of gases in respiratory parts of lungs, by induced protective reaction that increases dilution of inspired air. The years from second to fifth demonstrate stabilized changes and external respiratory system fixed in new functional state kept over next 15-18 years. After 20 years of service in mine, the external respiration system becomes overstrained with intensified compensatory pulmonary ventilation and protective reaction.

  3. Use of Jebsen Taylor Hand Function Test in evaluating the hand dexterity in people with Parkinson's disease.

    PubMed

    Mak, M K Y; Lau, E T L; Tam, V W K; Woo, C W Y; Yuen, S K Y

    2015-01-01

    To investigate the test-retest reliability of JTT in older patients with Parkinson's disease (PD); and to compare the Jebsen Taylor Hand Function Test (JTT) scores between PD and healthy subjects. Cross-sectional comparative study. Fifteen PD and fifteen healthy subjects performed the JTT and the time taken to complete the JTT was recorded. Test-retest reliabilities of JTT subtests and total score of both dominant and non-dominant hand were good to excellent (ICCs = 0.77-0.97) except J5 checkers which had moderate reliability. PD subjects required significantly longer time to finish subtests and the whole JTT (p < 0.05), except the subtest J1 writing of dominant hand that showed marginal significance (p = 0.059). JTT is a reliable and easily available assessment tool for assessing the hand function of PD subjects. PD subjects took a longer time to complete the JTT, suggesting that they have deficits in gross and fine functional dexterity. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. Translation, Validation, and Reliability of the Dutch Late-Life Function and Disability Instrument Computer Adaptive Test.

    PubMed

    Arensman, Remco M; Pisters, Martijn F; de Man-van Ginkel, Janneke M; Schuurmans, Marieke J; Jette, Alan M; de Bie, Rob A

    2016-09-01

    Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDI-CAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean=4.5 days). Pearson's r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were -.57 and -.53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. The Dutch LLFDI

  5. Production of functional sperm by subcutaneous auto-grafting of immature testes in rainbow trout.

    PubMed

    Hayashi, Makoto; Sakuma, Daika; Yoshizaki, Goro

    2018-02-01

    Sexually mature individuals are indispensable for breeding programs. Salmonids require a long period before reaching sexual maturity, so we aimed to shorten the period required to obtain functional sperm by grafting immature testicular fragments into mature recipients, which we predicted would allow the grafted testicular fragments to skip the long pre-pubertal period. First, we demonstrated successful subcutaneous auto-grafting of testicular fragments in rainbow trout. Unilateral testectomy was performed, and the isolated immature testicular fragment was auto-grafted into the subcutaneous space along the back of recipient fish. The grafted testicular fragments developed synchronously with the recipients' testis remaining in its body cavity, and both eventually produced functional sperm. Next, immature testicular fragments were auto-grafted into the subcutaneous space of sexually mature males. We achieved this, without immune rejection, by isolating and cryopreserving testes from immature fish, and rearing these unilaterally testectomized fish until sexual maturity. The cryopreserved testes were then auto-grafted into the original, now spermiating fish. The grated immature testicular fragments differentiated and produced functional sperm within 5 months after grafting. By combining this grafting method with a technique to avoid immune rejection, we expect to develop a practical method for producing sperm in a shorter period in salmonids. © 2017 Wiley Periodicals, Inc.

  6. Preseason Functional Movement Screen Component Tests Predict Severe Contact Injuries in Professional Rugby Union Players.

    PubMed

    Tee, Jason C; Klingbiel, Jannie F G; Collins, Robert; Lambert, Mike I; Coopoo, Yoga

    2016-11-01

    Tee, JC, Klingbiel, JFG, Collins, R, Lambert, MI, and Coopoo, Y. Preseason Functional Movement Screen component tests predict severe contact injuries in professional rugby union players. J Strength Cond Res 30(11): 3194-3203, 2016-Rugby union is a collision sport with a relatively high risk of injury. The ability of the Functional Movement Screen (FMS) or its component tests to predict the occurrence of severe (≥28 days) injuries in professional players was assessed. Ninety FMS test observations from 62 players across 4 different time periods were compared with severe injuries sustained during 6 months after FMS testing. Mean composite FMS scores were significantly lower in players who sustained severe injury (injured 13.2 ± 1.5 vs. noninjured 14.5 ± 1.4, Effect Size = 0.83, large) because of differences in in-line lunge (ILL) and active straight leg raise scores (ASLR). Receiver-operated characteristic curves and 2 × 2 contingency tables were used to determine that ASLR (cut-off 2/3) was the injury predictor with the greatest sensitivity (0.96, 95% confidence interval [CI] = 0.79-1.0). Adding the ILL in combination with ASLR (ILL + ASLR) improved the specificity of the injury prediction model (ASLR specificity = 0.29, 95% CI = 0.18-0.43 vs. ASLR + ILL specificity = 0.53, 95% CI = 0.39-0.66, p ≤ 0.05). Further analysis was performed to determine whether FMS tests could predict contact and noncontact injuries. The FMS composite score and various combinations of component tests (deep squat [DS] + ILL, ILL + ASLR, and DS + ILL + ASLR) were all significant predictors of contact injury. The FMS composite score also predicted noncontact injury, but no component test or combination thereof produced a similar result. These findings indicate that low scores on various FMS component tests are risk factors for injury in professional rugby players.

  7. Predictive value of health-related fitness tests for self-reported mobility difficulties among high-functioning elderly men and women.

    PubMed

    Hämäläinen, H Pauliina; Suni, Jaana H; Pasanen, Matti E; Malmberg, Jarmo J; Miilunpalo, Seppo I

    2006-06-01

    The functional independence of elderly populations deteriorates with age. Several tests of physical performance have been developed for screening elderly persons who are at risk of losing their functional independence. The purpose of the present study was to investigate whether several components of health-related fitness (HRF) are valid in predicting the occurrence of self-reported mobility difficulties (MD) among high-functioning older adults. Subjects were community-dwelling men and women, born 1917-1941, who participated in the assessment of HRF [6.1-m (20-ft) walk, one-leg stand, backwards walk, trunk side-bending, dynamic back extension, one-leg squat, 1-km walk] and who were free of MD in 1996 (no difficulties in walking 2- km, n=788; no difficulties in climbing stairs, n=647). Postal questionnaires were used to assess the prevalence of MD in 1996 and the occurrence of new MD in 2002. Logistic regression analysis was used as the statistical method. Both inability to perform the backwards walk and a poorer result in it were associated with risk of walking difficulties in the logistic model, with all the statistically significant single test items included. Results of 1-km walk time and one-leg squat strength test were also associated with risk, although the squat was statistically significant only in two older birth cohorts. Regarding stair-climbing difficulties, poorer results in the 1-km walk, dynamic back extension and one-leg squat tests were associated with increased risk of MD. The backwards walk, one-leg squat, dynamic back extension and 1-km walk tests were the best predictors of MD. These tests are recommended for use in screening high-functioning older people at risk of MD, as well as to target physical activity counseling to those components of HRF that are important for functional independence.

  8. Physiologic Dysfunction Scores and Cognitive Function Test Performance in United States Adults

    PubMed Central

    Kobrosly, Roni W; Seplaki, Christopher L; Jones, Courtney M; van Wijngaarden, Edwin

    2013-01-01

    Objective To investigate the relationship between a measure of cumulative physiologic dysfunction and specific domains of cognitive function. Methods We examined a summary score measuring physiological dysfunction, a multisystem measure of the body’s ability to effectively adapt to physical and psychological demands, in relation to cognitive function deficits in a population of 4511 adults aged 20 to 59 who participated in the third National Health and Nutrition Examination Survey (1988–1994). Measures of cognitive function comprised three domains: working memory, visuomotor speed, and perceptual-motor speed. ‘Physiologic dysfunction’ scores summarizing measures of cardiovascular, immunologic, kidney, and liver function were explored. We used multiple linear regression models to estimate associations between cognitive function measures and physiological dysfunction scores, adjusting for socioeconomic factors, test conditions, and self-reported health factors. Results We noted a dose-response relationship between physiologic dysfunction and working memory (coefficient = 0.207, 95% CI = (0.066, 0.348), p < 0.0001) that persisted after adjustment for all covariates (p = 0.03). We did not observe any significant relationships between dysfunction scores and visuomotor (p = 0.37) or perceptual-motor ability (p = 0.33). Conclusions Our findings suggest that multisystem physiologic dysfunction is associated with working memory. Future longitudinal studies are needed to clarify the underlying mechanisms and explore the persistency of this association into later life. We suggest that such studies should incorporate physiologic data, neuroendocrine parameters, and a wide range of specific cognitive domains. PMID:22155941

  9. The Unilateral Below Elbow Test: a function test for children with unilateral congenital below elbow deficiency.

    PubMed

    Bagley, Anita M; Molitor, Fred; Wagner, Lisa V; Tomhave, Wendy; James, Michelle A

    2006-07-01

    The Unilateral Below Elbow Test (UBET) was developed to evaluate function in bimanual activities for both the prosthesis wearer and non-wearer. Nine tasks were chosen for each of four age-specific categories defined by development stages of hand function (2-4y, 5-7y, 8-10y, and 11-21y). Two scales, Completion of Task and Method of Use, were designed to rate performance. To measure reliability, four occupational therapists scored samples of videotaped UBET performances. For Completion of Task, an interval scale, agreement in scoring was measured with interclass correlation coefficients (ICC; n=9; five females, four males). For Method of Use, a nominal scale, chance-adjusted association was calculated with Cohen's kappa coefficients (interobserver n=198; 111 females, 87 males; intraobserver n=93; 56 females, 37 males). For Completion of Task, the average ICC was 0.87 for the prosthesis-on condition, and 0.85 for the prosthesis-off condition. ICCs exceeded 0.80 for eight out of nine tasks for the two older age groups, but for only five out of nine tasks in the younger age groups. Higher inter- and intraobserver kappa coefficients for Method of Use resulted when scoring children with their prostheses on versus off. The oldest age group had lower kappa values than the other three groups. The UBET is recommended for the functional evaluation of Completion of Task in children with unilateral congenital below elbow deficiency with and without their prostheses. Method of Use scoring can evaluate individuals for directed therapy interventions or prosthetic training.

  10. Validation and clinical utility of the executive function performance test in persons with traumatic brain injury.

    PubMed

    Baum, C M; Wolf, T J; Wong, A W K; Chen, C H; Walker, K; Young, A C; Carlozzi, N E; Tulsky, D S; Heaton, R K; Heinemann, A W

    2017-07-01

    This study examined the relationships between the Executive Function Performance Test (EFPT), the NIH Toolbox Cognitive Function tests, and neuropsychological executive function measures in 182 persons with traumatic brain injury (TBI) and 46 controls to evaluate construct, discriminant, and predictive validity. Construct validity: There were moderate correlations between the EFPT and the NIH Toolbox Crystallized (r = -.479), Fluid Tests (r = -.420), and Total Composite Scores (r = -.496). Discriminant validity: Significant differences were found in the EFPT total and sequence scores across control, complicated mild/moderate, and severe TBI groups. We found differences in the organisation score between control and severe, and between mild and severe TBI groups. Both TBI groups had significantly lower scores in safety and judgement than controls. Compared to the controls, the severe TBI group demonstrated significantly lower performance on all instrumental activities of daily living (IADL) tasks. Compared to the mild TBI group, the controls performed better on the medication task, the severe TBI group performed worse in the cooking and telephone tasks. Predictive validity: The EFPT predicted the self-perception of independence measured by the TBI-QOL (beta = -0.49, p < .001) for the severe TBI group. Overall, these data support the validity of the EFPT for use in individuals with TBI.

  11. Which routine test for kidney function?

    PubMed Central

    Parkin, A; Smith, H C; Brocklebank, J T

    1989-01-01

    Eighty measurements of plasma creatinine concentration, height:creatinine ratio, and plasma beta 2 microglobulin concentration were made on 72 children (age 4 months-18.5 years) with known renal disease. Results were compared with simultaneous measurements of glomerular filtration rate using plasma clearance of 51Cr edetic acid to assess the performance of each test as an initial screening procedure of renal insufficiency. Height:creatinine index less than 2.1 was found to have a higher sensitivity and predictive value of a normal result than the other tests and is therefore the preferred test for a screening procedure. PMID:2510609

  12. Incidence of Thyroid Function Test Abnormalities in Patients Receiving Immune-Checkpoint Inhibitors for Cancer Treatment.

    PubMed

    Patel, Nisha Subhash; Oury, Anais; Daniels, Gregory A; Bazhenova, Lyudmila; Patel, Sandip Pravin

    2018-05-16

    With the advent of immune-checkpoint inhibitor (ICI) therapy (anti-CTLA-4, anti-PD-1), immune-related adverse events such as thyroid function test abnormalities (TFTAs) are common, with a reported incidence range of 2%-15% depending upon the ICI used. The aim of this study is to describe the incidence of TFTAs retrospectively in patients who received ICI therapy. A total of 285 patients were reviewed (178 male, 107 female; 16-94 years of age), of whom 218 had no baseline TFTAs, 61 had baseline TFTAs, and 6 had a history of thyroidectomy (excluded). At least one dose of ipilimumab and/or nivolumab or pembrolizumab was administered. Post-ICI therapy TFTAs were classified according to standard definitions of thyroid conditions when possible. A total of 35% (76/218) patients had new-onset TFTAs on ICI therapy. Of note, 70.5% (43/61) had baseline TFTAs that were exacerbated by ICI therapy. The median times to new-onset or exacerbated baseline TFTA were 46 and 33 days, respectively. Of note, 64.5% (20/31) of patients on both ipilimumab and nivolumab had new-onset TFTAs, compared with 31.3% (15/48) on ipilimumab, 31.5% (28/89) on nivolumab, and 26% (13/50) on pembrolizumab. The incidence of TFTAs with ICI therapy was higher than previously reported. Patients with baseline TFTAs and/or who were receiving ipilimumab and nivolumab combination therapy had a higher incidence of TFTAs than patients receiving single-agent ICI therapy. We recommend more frequent evaluation of thyroid function in the first 8 weeks, especially in patients with baseline TFTAs. Increased use of immune-checkpoint inhibitors in cancer treatment has highlighted the importance of monitoring for and treating immune-related adverse events. This study was conducted to assess the incidence of thyroid function test abnormalities retrospectively in patients with cancer on immune-checkpoint inhibitors, which is not known exactly. This study is unique in that it included patients with a variety of histologic

  13. Using a Functional Simulation of Crisis Management to Test the C2 Agility Model Parameters on Key Performance Variables

    DTIC Science & Technology

    2013-06-01

    1 18th ICCRTS Using a Functional Simulation of Crisis Management to Test the C2 Agility Model Parameters on Key Performance Variables...AND SUBTITLE Using a Functional Simulation of Crisis Management to Test the C2 Agility Model Parameters on Key Performance Variables 5a. CONTRACT...command in crisis management. C2 Agility Model Agility can be conceptualized at a number of different levels; for instance at the team

  14. GeneTools--application for functional annotation and statistical hypothesis testing.

    PubMed

    Beisvag, Vidar; Jünge, Frode K R; Bergum, Hallgeir; Jølsum, Lars; Lydersen, Stian; Günther, Clara-Cecilie; Ramampiaro, Heri; Langaas, Mette; Sandvik, Arne K; Laegreid, Astrid

    2006-10-24

    Modern biology has shifted from "one gene" approaches to methods for genomic-scale analysis like microarray technology, which allow simultaneous measurement of thousands of genes. This has created a need for tools facilitating interpretation of biological data in "batch" mode. However, such tools often leave the investigator with large volumes of apparently unorganized information. To meet this interpretation challenge, gene-set, or cluster testing has become a popular analytical tool. Many gene-set testing methods and software packages are now available, most of which use a variety of statistical tests to assess the genes in a set for biological information. However, the field is still evolving, and there is a great need for "integrated" solutions. GeneTools is a web-service providing access to a database that brings together information from a broad range of resources. The annotation data are updated weekly, guaranteeing that users get data most recently available. Data submitted by the user are stored in the database, where it can easily be updated, shared between users and exported in various formats. GeneTools provides three different tools: i) NMC Annotation Tool, which offers annotations from several databases like UniGene, Entrez Gene, SwissProt and GeneOntology, in both single- and batch search mode. ii) GO Annotator Tool, where users can add new gene ontology (GO) annotations to genes of interest. These user defined GO annotations can be used in further analysis or exported for public distribution. iii) eGOn, a tool for visualization and statistical hypothesis testing of GO category representation. As the first GO tool, eGOn supports hypothesis testing for three different situations (master-target situation, mutually exclusive target-target situation and intersecting target-target situation). An important additional function is an evidence-code filter that allows users, to select the GO annotations for the analysis. GeneTools is the first "all in one

  15. Can the Platelet Function Analyzer (PFA)-100 test substitute for the template bleeding time in routine clinical practice?

    PubMed

    Francis, J; Francis, D; Larson, L; Helms, E; Garcia, M

    1999-01-01

    The bleeding time (BT) is widely used in clinical medicine as a screening test of platelet function, although its deficiencies in such a role are well recognized. The Platelet Function Analyzer (PFA)-100 measures the ability of platelets activated in a high-shear environment to occlude an aperture in a membrane treated with collagen and epinephrine (CEPI) or collagen and ADP (CADP). The time taken for flow across the membrane to stop (closure time) is recorded. This study compared the PFA-100 with the BT as a screening test of platelet dysfunction in 113 hospital inpatients. The PFA-100 test was performed initially using the CEPI cartridge; CADP tests were performed on those with abnormal (> 163 s) CEPI closure times. Whole blood platelet aggregation studies and chart review were performed on patients in whom the BT and PFA-100 results did not agree.Abnormal bleeding times and PFA-100 results were obtained in 20.4% and 35.4% of patients, respectively. The results of BT and PFA-100 agreed in 74.3% of patients. Of the 29 patients in whom the BT and PFA-100 results were discordant, whole blood platelet aggregation studies supported the PFA-100 result in 25 (86.2%). The PFA-100 was more sensitive to aspirin-induced platelet dysfunction and was more rapidly and cheaply performed than the BT. Since the PFA-100 test reflects platelet function better than the BT, we conclude that this test could replace the BT as a first-line screening test for platelet dysfunction in clinical practice.

  16. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    PubMed

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, p<0.001) and 4MGS (r=-0.583, p=0.003). This study demonstrates excellent inter-observer and test-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Aging and strategic retrieval in a cued-recall test: the role of executive functions and fluid intelligence.

    PubMed

    Taconnat, Laurence; Clarys, David; Vanneste, Sandrine; Bouazzaoui, Badiâa; Isingrini, Michel

    2007-06-01

    Cued-recall in episodic memory was investigated in relation to low and high cognitive support at retrieval, executive function level and fluid intelligence level in 81 healthy adults divided first into two age groups (young and elderly adults). The first analyses showed that age-related differences were greater when a low cognitive support was provided to recall the words. An individual index of loss of performance when the number of cues was decreased was then calculated. Hierarchical regression analysis revealed that the executive functions measure (perseverative errors on the Wisconsin Card Sorting Test) was a better candidate than the fluid intelligence measure (Cattell's culture fair test) to account for the age-related variance of the size of performance loss. These findings suggest that age differences in implementing strategic retrieval may be mainly due to a decline in executive functions.

  18. Novel Electrochemical Test Bench for Evaluating the Functional Fatigue Life of Biomedical Alloys

    NASA Astrophysics Data System (ADS)

    Ijaz, M. F.; Dubinskiy, S.; Zhukova, Y.; Korobkova, A.; Pustov, Y.; Brailovski, V.; Prokoshkin, S.

    2017-08-01

    The aim of the present work was first to develop and validate a test bench that simulates the in vitro conditions to which the biomedical implants will be actually subjected in vivo. For the preliminary application assessments, the strain-controlled fatigue tests of biomedically pure Ti and Ti-Nb-Zr alloy in simulated body fluid were undertaken. The in situ open-circuit potential measurements from the test bench demonstrated a strong dependence on the dynamic cycling and kind of material under testing. The results showed that during fatigue cycling, the passive oxide film formed on the surface of Ti-Nb-Zr alloy was more resistant to fatigue degradation when compared with pure Ti. The Ti-Nb-Zr alloy exhibited prolonged fatigue life when compared with pure Ti. The fractographic features of both materials were also characterized using scanning electron microscopy. The electrochemical results and the fractographic evidence confirmed that the prolonged functional fatigue life of the Ti-Nb-Zr alloy is apparently ascribable to the reversible martensitic phase transformation.

  19. Gastroesophageal reflux symptoms are not sufficient to guide esophageal function testing in lung transplant candidates.

    PubMed

    Posner, S; Zheng, J; Wood, R K; Shimpi, R A; Hartwig, M G; Chow, S-C; Leiman, D A

    2018-05-01

    Gastroesophageal reflux disease and esophageal dysmotility are prevalent in patients with advanced lung disease and are associated with graft dysfunction following lung transplantation. As a result, many transplant centers perform esophageal function testing as part of the wait-listing process but guidelines for testing in this population are lacking. The aim of this study is to describe whether symptoms of gastroesophageal reflux correlate with abnormal results on pH-metry and high-resolution manometry and can be used to identify those who require testing. We performed a retrospective cohort study of 226 lung transplant candidates referred for high-resolution manometry and pH-metry over a 12-month period in 2015. Demographic data, results of a standard symptom questionnaire and details of esophageal function testing were obtained. Associations between the presence of symptoms and test results were analyzed using Fisher's exact tests and multivariable logistic regression. The most common lung disease diagnosis was interstitial lung disease (N = 131, 58%). Abnormal pH-metry was seen in 116 (51%) patients and the presence of symptoms was significantly associated with an abnormal study (p < 0.01). Dysmotility was found in 98 (43%) patients, with major peristaltic or esophageal outflow disorders in 45 (20%) patients. Symptoms were not correlated with findings on esophageal high-resolution manometry. Fifteen of 25 (60%) asymptomatic patients had an abnormal manometry or pH-metry. These results demonstrate that in patients with advanced lung disease, symptoms of gastroesophageal reflux increase the likelihood of elevated acid exposure on pH-metry but were not associated with dysmotility. Given the proportion of asymptomatic patients with abnormal studies and associated post-transplant risks, a practice of universal high-resolution manometry and pH-metry testing in this population is justifiable.

  20. Is functional MR imaging assessment of hemispheric language dominance as good as the Wada test?: a meta-analysis.

    PubMed

    Dym, R Joshua; Burns, Judah; Freeman, Katherine; Lipton, Michael L

    2011-11-01

    To perform a systematic review and meta-analysis to quantitatively assess functional magnetic resonance (MR) imaging lateralization of language function in comparison with the Wada test. This study was determined to be exempt from review by the institutional review board. A systematic review and meta-analysis were performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A structured Medline search was conducted to identify all studies that compared functional MR imaging with the Wada test for determining hemispheric language dominance prior to brain surgery. Studies meeting predetermined inclusion criteria were selected independently by two radiologists who also assessed their quality using the Quality Assessment of Diagnostic Accuracy Studies tool. Language dominance was classified as typical (left hemispheric language dominance) or atypical (right hemispheric language dominance or bilateral language representation) for each patient. A meta-analysis was then performed by using a bivariate random-effects model to derive estimates of sensitivity and specificity, with Wada as the standard of reference. Subgroup analyses were also performed to compare the different functional MR imaging techniques utilized by the studies. Twenty-three studies, comprising 442 patients, met inclusion criteria. The sensitivity and specificity of functional MR imaging for atypical language dominance (compared with the Wada test) were 83.5% (95% confidence interval: 80.2%, 86.7%) and 88.1% (95% confidence interval: 87.0%, 89.2%), respectively. Functional MR imaging provides an excellent, noninvasive alternative for language lateralization and should be considered for the initial preoperative assessment of hemispheric language dominance. Further research may help determine which functional MR methods are most accurate for specific patient populations. RSNA, 2011

  1. The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

    NASA Technical Reports Server (NTRS)

    Peters, B. T.; Mulavara, A. P.; Brady, R.; Miller, C. A.; Richards, J. T.; Warren, L. E.; Cohen, H. S.; Bloomberg, J. J.

    2006-01-01

    After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The

  2. Comparison of hypertabastic survival model with other unimodal hazard rate functions using a goodness-of-fit test.

    PubMed

    Tahir, M Ramzan; Tran, Quang X; Nikulin, Mikhail S

    2017-05-30

    We studied the problem of testing a hypothesized distribution in survival regression models when the data is right censored and survival times are influenced by covariates. A modified chi-squared type test, known as Nikulin-Rao-Robson statistic, is applied for the comparison of accelerated failure time models. This statistic is used to test the goodness-of-fit for hypertabastic survival model and four other unimodal hazard rate functions. The results of simulation study showed that the hypertabastic distribution can be used as an alternative to log-logistic and log-normal distribution. In statistical modeling, because of its flexible shape of hazard functions, this distribution can also be used as a competitor of Birnbaum-Saunders and inverse Gaussian distributions. The results for the real data application are shown. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. The short Synacthen (corticotropin) test can be used to predict recovery of hypothalamo-pituitary-adrenal axis function.

    PubMed

    Pofi, Riccardo; Feliciano, Chona; Sbardella, Emilia; Argese, Nicola; Woods, Conor P; Grossman, Ashley B; Jafar-Mohammadi, Bahram; Gleeson, Helena; Lenzi, Andrea; Isidori, Andrea M; Tomlinson, Jeremy W

    2018-05-25

    The 250μg Short Synacthen (corticotropin) Test (SST) is the most commonly used tool to assess hypothalamo-pituitary-adrenal (HPA) axis function. There are many potentially reversible causes of adrenal insufficiency (AI), but currently no data to guide clinicians as to the frequency of repeat testing or likelihood of HPA axis recovery. To use the SST results to predict recovery of adrenal function. A retrospective analysis of data from 1912 SSTs. 776 patients with reversible causes of AI were identified who had at least two SSTs performed. A subgroup analysis was performed on individuals previously treated with suppressive doses of glucocorticoids (n=110). Recovery of HPA axis function. SST 30-minute cortisol levels above or below 350nmol/L (12.7μg/dL) best predicted HPA axis recovery (AUC ROC=0.85; median recovery time 334 vs. 1368 days, p=8.5x10-13): 99% of patients with a 30-minute cortisol >350nmol/L recovered adrenal function within 4-years, compared with 49% in those with cortisol levels <350nmol/L. In patients exposed to suppressive doses of glucocorticoids, delta cortisol (30-minute - basal) was the best predictor of recovery (AUC ROC = 0.77; median recovery time 262 vs. 974 days, p=7.0x10-6). No patient with a delta cortisol <100nmol (3.6μg/dL) and a subsequent random cortisol <200nmol/L (7.3μg/dL) measured approximately 1-year later recovered HPA axis function. Cortisol levels across an SST can be used to predict recovery of AI and may guide the frequency of repeat testing and inform both clinicians and patients as to the likelihood of restoration of HPA axis function.

  4. Development of a cognitive function test using virtual reality technology: examination in healthy participants.

    PubMed

    Sakai, Hiromi; Nagano, Akinori; Seki, Keiko; Okahashi, Sayaka; Kojima, Maki; Luo, Zhiwei

    2018-07-01

    We developed a virtual reality test to assess the cognitive function of Japanese people in near-daily-life environment, namely, a virtual shopping test (VST). In this test, participants were asked to execute shopping tasks using touch panel operations in a "virtual shopping mall." We examined differences in VST performances among healthy participants of different ages and correlations between VST and screening tests, such as the Mini-Mental State Examination (MMSE) and Everyday Memory Checklist (EMC). We included 285 healthy participants between 20 and 86 years of age in seven age groups. Therefore, each VST index tended to decrease with advancing age; differences among age groups were significant. Most VST indices had a significantly negative correlation with MMSE and significantly positive correlation with EMC. VST may be useful for assessing general cognitive decline; effects of age must be considered for proper interpretation of the VST scores.

  5. [Testing and analyzing the lung functions in the normal population in Hebei province].

    PubMed

    Chen, Li; Zhao, Ming; Han, Shao-mei; Li, Zhong-ming; Zhu, Guang-jin

    2004-08-01

    To investigate the lung function of the normal subjects living in Hebei province and its correlative factors such as living circumstance, age, height, and body weight. The lung volumes and breath capacities of 1,587 normal subjects were tested by portable spirometers (Scope Rotry) from August to October in 2002. The influences of living circumstance, age, gender, height, and body weight on lung functions were observed and analyzed. No significant difference was found between urban and rural areas in all indexes (P > 0.05); however, significant difference existed between male and female subjects (P = 0.000). The change trends of lung function in male and female subjects were similar. Growth spurt appeared at the age of 12-16 years in male subjects and 12-14 years in female subjects. Vital capacity (VC), forced vital capacity (FVC), and forced expiratory volume in one second (FEV1) reached their peaks at the age of 26-34 years and then decreased with age. Peak expiratory flow (PEF), 25% forced expiratory flow (FEF50%), and 75% forced expiratory flow (FEF75%) appeared at the age of 18 and then went down with age. Both height and weight had a correlation with all the indexes of lung functions, although the influence of height is stronger than weight. All the indexes of lung function have correlations with age, height, and weight. Lung function changes with aging, therefore different expected values shall be available for the adolescence, young adults, and middle-aged and old people. This study provides reference values of lung function for normal population.

  6. Functional Assays for Neurotoxicity Testing

    EPA Science Inventory

    Neurobehavioral and pathological evaluations of the nervous system are complementary components of basic research and toxicity testing of pharmaceutical and environmental chemicals. While neuropathological assessments provide insight as to cellular changes in neurons, behavioral ...

  7. Functional Assays for Neurotoxicity Testing*

    EPA Science Inventory

    Neurobehavioral and pathological evaluations of the nervous system are complementary components of basic research and toxicity testing of pharmaceutical and environmental chemicals. While neuropathological assessments provide insight as to cellular changes in neurons, behavioral ...

  8. The use of a battery of tracking tests in the quantitative evaluation of neurological function

    NASA Technical Reports Server (NTRS)

    Repa, B. S.; Albers, J. W.; Potvin, A. R.; Tourtellotte, W. W.

    1972-01-01

    A tracking test battery has been applied in a drug trail designed to compare the efficacy of L-DOPA and amantadine to that of L-DOPA and placebo in the treatment of 28 patients with Parkinson's disease. The drug trial provided an ideal opportunity for objectively evaluating the usefulness of tracking tests in assessing changes in neurologic function. Evaluating changes in patient performance resulting from disease progression and controlled clinical trials is of great importance in establishing effective treatment programs.

  9. Clinical utility of balloon expulsion test for functional defecation disorders.

    PubMed

    Seong, Moo-Kyung

    2016-02-01

    I investigated the diagnostic accuracy of balloon expulsion test (BET) with various techniques to find out the most appropriate method, and tried to confirm its clinical utility in diagnosing functional defecation disorders (FDD) in constipated patients. Eighty-seven patients constituted the study population. FDD was defined when patients had at least two positive findings in defecography, manometry, and electromyography. BET was done 4 times in each patient with 2 different positions and 2 different volumes. The positions were seated position (SP) and left lateral decubitus position (LDP). The volumes were fixed volume (FV) of 60 mL and individualized volume with which patient felt a constant desire to defecate (CDV). The results of BETs with 4 different settings (LDP-FV, LDP-CDV, SP-FV, and SP-CDV) were statistically compared and analyzed. Of 87 patients, 23 patients (26.4%) had at least two positive findings in 3 tests and thus were diagnosed to have FDD. On receiver operating characteristic curve analysis, area under curve was highest in BET with SP-FV. With a cutoff value of 30 seconds, the specificity of BET with SP-FV was 86.0%, sensitivity was 73.9%, negative predictive value was 89.8%, positive predictive value was 65.4%, and accuracy rate was 82.8% for diagnosing FDD. SP-FV is the most appropriate method for BET. In this setting, BET has a diagnostic accuracy sufficient to identify constipated patients who do not have FDD. Patients with negative results in BET with SP-FV may not need other onerous tests to exclude FDD.

  10. Modern psychophysical tests to assess olfactory function.

    PubMed

    Eibenstein, A; Fioretti, A B; Lena, C; Rosati, N; Amabile, G; Fusetti, M

    2005-07-01

    The sense of smell significantly contributes to quality of life. In recent years much progress has been made in understanding the biochemistry, physiology and pathology of the human olfactory system. Olfactory disorders may arise not only from upper airway phlogosis but also from neurodegenerative disease. Hyposmia may precede motor signs in Parkinson's disease and cognitive deficit in Alzheimer's disease. These findings suggest the complementary role of olfactory tests in the diagnosis and management of neurodegenerative diseases. In this report we present a review of modern olfactory tests and their clinical applications. Although rarely employed in routine clinical practice, the olfactory test evaluates the ability of odour identification and is a useful diagnostic tool for olfaction evaluation. Olfactory screening tests are also available. In this work we strongly recommend the importance of an ENT evaluation before the test administration and dissuade from a self-administration of an olfactory test.

  11. The use of regression analysis in determining reference intervals for low hematocrit and thrombocyte count in multiple electrode aggregometry and platelet function analyzer 100 testing of platelet function.

    PubMed

    Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D

    2017-11-01

    Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.

  12. Influences on the Test-Retest Reliability of Functional Connectivity MRI and its Relationship with Behavioral Utility.

    PubMed

    Noble, Stephanie; Spann, Marisa N; Tokoglu, Fuyuze; Shen, Xilin; Constable, R Todd; Scheinost, Dustin

    2017-11-01

    Best practices are currently being developed for the acquisition and processing of resting-state magnetic resonance imaging data used to estimate brain functional organization-or "functional connectivity." Standards have been proposed based on test-retest reliability, but open questions remain. These include how amount of data per subject influences whole-brain reliability, the influence of increasing runs versus sessions, the spatial distribution of reliability, the reliability of multivariate methods, and, crucially, how reliability maps onto prediction of behavior. We collected a dataset of 12 extensively sampled individuals (144 min data each across 2 identically configured scanners) to assess test-retest reliability of whole-brain connectivity within the generalizability theory framework. We used Human Connectome Project data to replicate these analyses and relate reliability to behavioral prediction. Overall, the historical 5-min scan produced poor reliability averaged across connections. Increasing the number of sessions was more beneficial than increasing runs. Reliability was lowest for subcortical connections and highest for within-network cortical connections. Multivariate reliability was greater than univariate. Finally, reliability could not be used to improve prediction; these findings are among the first to underscore this distinction for functional connectivity. A comprehensive understanding of test-retest reliability, including its limitations, supports the development of best practices in the field. © The Author 2017. Published by Oxford University Press.

  13. Is low cognitive functioning a predictor or consequence of major depressive disorder? A test in two longitudinal birth cohorts.

    PubMed

    Schaefer, Jonathan D; Scult, Matthew A; Caspi, Avshalom; Arseneault, Louise; Belsky, Daniel W; Hariri, Ahmad R; Harrington, Honalee; Houts, Renate; Ramrakha, Sandhya; Poulton, Richie; Moffitt, Terrie E

    2017-11-16

    Cognitive impairment has been identified as an important aspect of major depressive disorder (MDD). We tested two theories regarding the association between MDD and cognitive functioning using data from longitudinal cohort studies. One theory, the cognitive reserve hypothesis, suggests that higher cognitive ability in childhood decreases risk of later MDD. The second, the scarring hypothesis, instead suggests that MDD leads to persistent cognitive deficits following disorder onset. We tested both theories in the Dunedin Study, a population-representative cohort followed from birth to midlife and assessed repeatedly for both cognitive functioning and psychopathology. We also used data from the Environmental Risk Longitudinal Twin Study to test whether childhood cognitive functioning predicts future MDD risk independent of family-wide and genetic risk using a discordant twin design. Contrary to both hypotheses, we found that childhood cognitive functioning did not predict future risk of MDD, nor did study members with a past history of MDD show evidence of greater cognitive decline unless MDD was accompanied by other comorbid psychiatric conditions. Our results thus suggest that low cognitive functioning is related to comorbidity, but is neither an antecedent nor an enduring consequence of MDD. Future research may benefit from considering cognitive deficits that occur during depressive episodes from a transdiagnostic perspective.

  14. Neuropsychological test performance and prediction of functional capacities among Spanish-speaking and English-speaking patients with dementia.

    PubMed

    Loewenstein, D A; Rubert, M P; Argüelles, T; Duara, R

    1995-03-01

    Neuropsychological measures have been widely used by clinicians to assist them in making judgments regarding a cognitively impaired patient's ability to independently perform important activities of daily living. However, important questions have been raised concerning the degree to which neuropsychological instruments can predict a broad array of specific functional capacities required in the home environment. In the present study, we examined 127 English-speaking and 56 Spanish-speaking patients with Alzheimer's disease (AD) and determined the extent to which various neuropsychological measures and demographic variables were predictive of performance on functional measures administered within the clinical setting. Among English-speaking AD patients, Block Design and Digit-Span of the WAIS-R, as well as tests of language were among the strongest predictors of functional performance. For Spanish-speakers, Block Design, The Mini-Mental State Evaluation (MMSE) and Digit Span had the optimal predictive power. When stepwise regression was conducted on the entire sample of 183 subjects, ethnicity emerged as a statistically significant predictor variable on one of the seven functional tests (writing a check). Despite the predictive power of several of the neuropsychological measures for both groups, most of the variability in objective functional performance could not be explained in our regression models. As a result, it would appear prudent to include functional measures as part of a comprehensive neuropsychological evaluation for dementia.

  15. Mobility stress test approach to predicting frailty, disability, and mortality in high-functioning older adults.

    PubMed

    Verghese, Joe; Holtzer, Roee; Lipton, Richard B; Wang, Cuiling

    2012-10-01

    To examine the validity of the Walking While Talking Test (WWT), a mobility stress test, to predict frailty, disability, and death in high-functioning older adults. Prospective cohort study. Community sample. Six hundred thirty-one community-residing adults aged 70 and older participating in the Einstein Aging Study (mean follow-up 32 months). High-functioning status at baseline was defined as absence of disability and dementia and normal walking speeds. Hazard ratios (HRs) for frailty, disability, and all-cause mortality. Frailty was defined as presence of three out of the following five attributes: weight loss, weakness, exhaustion, low physical activity, and slow gait. The predictive validity of the WWT was also compared with that of the Short Physical Performance Battery (SPPB) for study outcomes. Two hundred eighteen participants developed frailty, 88 developed disability, and 49 died. Each 10-cm/s decrease in WWT speed was associated with greater risk of frailty (HR = 1.12, 95% confidence interval (CI) = 1.06-1.18), disability (HR = 1.13, 95% CI = 1.03-1.23), and mortality (HR = 1.13, 95% CI = 1.01-1.27). Most associations remained robust even after accounting for potential confounders and gait speed. Comparisons of HRs and model fit suggest that the WWT may better predict frailty whereas SPPB may better predict disability. Mobility stress tests such as the WWT are robust predictors of risk of frailty, disability, and mortality in high-functioning older adults. © 2012, Copyright the Authors Journal compilation © 2012, The American Geriatrics Society.

  16. Effect of laryngeal anesthesia on pulmonary function testing in normal subjects.

    PubMed

    Kuna, S T; Woodson, G E; Sant'Ambrogio, G

    1988-03-01

    Pulmonary function tests (PFT) were performed on 11 normal subjects before and after topical anesthesia of the larynx. The PFT consisted of flow volume loops and body box determinations of functional residual capacity and airway resistance, each performed in triplicate. After the first set of tests, cotton pledgets soaked in 4% lidocaine were held in the pyriform sinuses for 2 min to block the superior laryngeal nerves. In addition, 1.5 ml of 10% cocaine was dropped on the vocal cords via indirect laryngoscopy. PFT were repeated 5 min after anesthesia. Besides routine analysis of the flow volume loops, areas under the inspiratory (Area I) and expiratory (Area E) portions of the loops were calculated by planimetry. Area I, peak inspiratory flow (PIF), as well as forced inspiratory flow at 25, 50, and 75% forced vital capacity (FVC), decreased after anesthesia. Peak expiratory flow decreased after anesthesia, but Area E and forced expiratory flow at 25, 50, and 75% FVC were unchanged. This protocol also was performed in 12 normal subjects with isotonic saline being substituted for the lidocaine and cocaine. In this group, no significant differences were observed when flow volume loop parameters were compared before and after topical application of saline. In 5 spontaneously breathing anesthetized dogs, posterior cricoarytenoid muscle and afferent superior laryngeal nerve activity were recorded before and after laryngeal anesthesia performed with the same procedure used in the human subjects. Laryngeal anesthesia resulted in a substantial decrease or a complete disappearance of afferent SLN activity recorded during unobstructed and obstructed respiration. The data suggest that laryngeal receptors help modulate upper airway patency in man.

  17. Colon Transit Time Test in Korean Children with Chronic Functional Constipation

    PubMed Central

    Yoo, Ha Yeong; Kim, Mock Ryeon; Park, Hye Won; Son, Jae Sung

    2016-01-01

    Purpose Each ethnic group has a unique life style, including diets. Life style affects bowel movement. The aim of this study is to describe the results of colon transit time (CTT) tests in Korean children who had chronic functional constipation based on highly refined data. Methods One hundred ninety (86 males) out of 415 children who performed a CTT test under the diagnosis of chronic constipation according to Rome III criteria at Konkuk University Medical Center from January 2006 through March 2015 were enrolled in this study. Two hundreds twenty-five children were excluded on the basis of CTT test result, defecation diary, and clinical setting. Shapiro-Wilk and Mann-Whitney U, and chi-square tests were used for statistical analysis. Results The median value and interquartile range (IQR) of CTT was 54 (37.5) hours in Encopresis group, and those in non-encopresis group was 40.2 (27.9) hours (p<0.001). The frequency of subtype between non-encopresis group and encopresis was statistically significant (p=0.002). The non-encopresis group (n=154, 81.1%) was divided into normal transit subgroup (n=84, 54.5%; median value and IQR of CTT=26.4 [9.6] hours), outlet obstruction subgroup (n=18, 11.7%; 62.4 [15.6] hours), and slow transit subgroup (n=52, 33.8%; 54.6 [21.0] hours]. The encopresis group (n=36, 18.9%) was divided into normal transit subgroup (n=8, 22.2%; median value and IQR of CTT=32.4 [9.9] hours), outlet obstruction subgroup (n=8, 22.2%; 67.8 [34.8] hours), and slow transit subgroup (n=20, 55.6%; 59.4 [62.7]hours). Conclusion This study provided the basic pattern and value of the CTT test in Korean children with chronic constipation. PMID:27064388

  18. Accuracy of indocyanine green pulse spectrophotometry clearance test for liver function prediction in transplanted patients

    PubMed Central

    Hsieh, Chung-Bao; Chen, Chung-Jueng; Chen, Teng-Wei; Yu, Jyh-Cherng; Shen, Kuo-Liang; Chang, Tzu-Ming; Liu, Yao-Chi

    2004-01-01

    AIM: To investigate whether the non-invasive real-time Indocynine green (ICG) clearance is a sensitive index of liver viability in patients before, during, and after liver transplantation. METHODS: Thirteen patients were studied, two before, three during, and eight following liver transplantation, with two patients suffering acute rejection. The conventional invasive ICG clearance test and ICG pulse spectrophotometry non-invasive real-time ICG clearance test were performed simultaneously. Using linear regression analysis we tested the correlation between these two methods. The transplantation condition of these patients and serum total bilirubin (T. Bil), alanine aminotransferase (ALT), and platelet count were also evaluated. RESULTS: The correlation between these two methods was excellent (r2 = 0.977). CONCLUSION: ICG pulse spectrophotometry clearance is a quick, non-invasive, and reliable liver function test in transplantation patients. PMID:15285026

  19. Age-related cognitive decline as a function of daytime testing.

    PubMed

    Puiu, Andrei Alexandru

    2017-05-01

    The current study investigates the effects of age, cognitive load, optimal time-of-day testing, and irrelevant background noise suppression on mental processing. One hundred and seventy-eight young (M = 22.97 years) and 114 old adults (M = 56.38 years) were assessed for implicit learning and speed of information processing under irrelevant sound interference early during daytime (7AM-2.30PM) or in the afternoons (3PM-midnight). No direct effect of irrelevant speech effect was found on implicit learning. An optimal time of testing per age group was identified according to the ability to suppress irrelevant auditory information. If no semantic meaning was derived from the sound conditions, irrelevant sound was easily inhibited leaving no room for declined cognitive performance. This suggests an intact phonological inhibition in older adults and a further circumvention of the phonological loop. However, when difficulty was increased, a widened performance gap between young and old people could be observed. Education modulated difficult performance irrespective of age. With increasing age, task demand fulfillment becomes a function of a limited time mechanism. If extraneous time is not adapted to cognitive skills and performance, higher order processing cannot be reached, rendering older adults slower than their younger counterparts.

  20. Playskin Lift: Development and Initial Testing of an Exoskeletal Garment to Assist Upper Extremity Mobility and Function.

    PubMed

    Lobo, Michele A; Koshy, John; Hall, Martha L; Erol, Ozan; Cao, Huantian; Buckley, Jenner M; Galloway, James C; Higginson, Jill

    2016-03-01

    A person's ability to move his or her arms against gravity is important for independent performance of critical activities of daily living and for exploration that facilitates early cognitive, language, social, and perceptual-motor development. Children with a variety of diagnoses have difficulty moving their arms against gravity. The purpose of this technical report is to detail the design process and initial testing of a novel exoskeletal garment, the Playskin Lift, that assists and encourages children to lift their arms against gravity. This report details the design theory and process, the device, and the results of field testing with a toddler with impaired upper extremity function due to arthrogryposis multiplex congenita. The Playskin Lift is an inexpensive (<$30 material costs), easy to use (5/5 rating), comfortable (5/5 rating), and attractive (4/5 rating) device. While wearing the device, the child was able to contact objects more often throughout an increased play space, to look at toys more while contacting them, and to perform more complex interactions with toys. This report details initial testing with one child. Future testing with more participants is recommended. These results suggest that by considering the broad needs of users, including cost, accessibility, comfort, aesthetics, and function, we can design inexpensive devices that families and clinicians can potentially fabricate in their own communities to improve function, participation, exploration, and learning for children with disabilities. © 2016 American Physical Therapy Association.

  1. Playskin Lift: Development and Initial Testing of an Exoskeletal Garment to Assist Upper Extremity Mobility and Function

    PubMed Central

    Koshy, John; Hall, Martha L.; Erol, Ozan; Cao, Huantian; Buckley, Jenner M.; Galloway, James C.; Higginson, Jill

    2016-01-01

    Background A person's ability to move his or her arms against gravity is important for independent performance of critical activities of daily living and for exploration that facilitates early cognitive, language, social, and perceptual-motor development. Children with a variety of diagnoses have difficulty moving their arms against gravity. Objective The purpose of this technical report is to detail the design process and initial testing of a novel exoskeletal garment, the Playskin Lift, that assists and encourages children to lift their arms against gravity. Design This report details the design theory and process, the device, and the results of field testing with a toddler with impaired upper extremity function due to arthrogryposis multiplex congenita. Results The Playskin Lift is an inexpensive (<$30 material costs), easy to use (5/5 rating), comfortable (5/5 rating), and attractive (4/5 rating) device. While wearing the device, the child was able to contact objects more often throughout an increased play space, to look at toys more while contacting them, and to perform more complex interactions with toys. Limitations This report details initial testing with one child. Future testing with more participants is recommended. Conclusions These results suggest that by considering the broad needs of users, including cost, accessibility, comfort, aesthetics, and function, we can design inexpensive devices that families and clinicians can potentially fabricate in their own communities to improve function, participation, exploration, and learning for children with disabilities. PMID:26316534

  2. An Automated Test of Rat Forelimb Supination Quantifies Motor Function Loss and Recovery After Corticospinal Injury.

    PubMed

    Sindhurakar, Anil; Butensky, Samuel D; Meyers, Eric; Santos, Joshua; Bethea, Thelma; Khalili, Ashley; Sloan, Andrew P; Rennaker, Robert L; Carmel, Jason B

    2017-02-01

    Rodents are the primary animal model of corticospinal injury and repair, yet current behavioral tests do not show the large deficits after injury observed in humans. Forearm supination is critical for hand function and is highly impaired by corticospinal injury in both humans and rats. Current tests of rodent forelimb function do not measure this movement. To determine if quantification of forelimb supination in rats reveals large-scale functional loss and partial recovery after corticospinal injury. We developed a knob supination device that quantifies supination using automated and objective methods. Rats in a reaching box have to grasp and turn a knob in supination in order to receive a food reward. Performance on this task and the single pellet reaching task were measured before and after 2 manipulations of the pyramidal tract: a cut lesion of 1 pyramid and inactivation of motor cortex using 2 different drug doses. A cut lesion of the corticospinal tract produced a large deficit in supination. In contrast, there was no change in pellet retrieval success. Supination function recovered partially over 6 weeks after injury, and a large deficit remained. Motor cortex inactivation produced a dose-dependent loss of knob supination; the effect on pellet reaching was more subtle. The knob supination task reveals in rodents 3 signature hand function changes observed in humans with corticospinal injury: (1) large-scale loss with injury, (2) partial recovery in the weeks after injury, and (3) loss proportional to degree of dysfunction.

  3. Congenital hypothyroidism in a kitten resulting in decreased IGF-I concentration and abnormal liver function tests.

    PubMed

    Quante, Saskia; Fracassi, Federico; Gorgas, Daniela; Kircher, Patrick R; Boretti, Felicitas S; Ohlerth, Stefanie; Reusch, Claudia E

    2010-06-01

    A 7-month-old male kitten was presented with chronic constipation and retarded growth. Clinical examination revealed disproportional dwarfism with mild skeletal abnormalities and a palpable thyroid gland. The presumptive diagnosis of congenital hypothyroidism was confirmed by low serum total thyroxine (tT(4)) concentration prior to and after the administration of thyroid stimulation hormone (TSH), increased endogenous TSH concentration and abnormal thyroid scintigraphic scan. The kitten had abnormal liver function tests and decreased insulin-like growth factor 1 (IGF-1) concentration, both of which returned to normal in correspondence with an improvement of the clinical signs after 6 weeks of thyroxine therapy. Congenital hypothyroidism is a rare disease that may present with considerable variation in clinical manifestation. In cases in which clinical signs are ambiguous, disorders such as portosystemic shunt and hyposomatotropism have to be taken into account as differential diagnosis. As hypothyroidism may be associated with abnormal liver function tests and low IGF-1 concentrations, test results have to be interpreted carefully. Copyright 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.

  4. Using Cochran's Z Statistic to Test the Kernel-Smoothed Item Response Function Differences between Focal and Reference Groups

    ERIC Educational Resources Information Center

    Zheng, Yinggan; Gierl, Mark J.; Cui, Ying

    2010-01-01

    This study combined the kernel smoothing procedure and a nonparametric differential item functioning statistic--Cochran's Z--to statistically test the difference between the kernel-smoothed item response functions for reference and focal groups. Simulation studies were conducted to investigate the Type I error and power of the proposed…

  5. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function.

    PubMed

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A; Lu, Zhong-Lin; Myung, Jay I

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias.

  6. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function

    PubMed Central

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A.; Lu, Zhong-Lin; Myung, Jay I.

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias. PMID:27105061

  7. Age-Related Differences in Test-Retest Reliability in Resting-State Brain Functional Connectivity

    PubMed Central

    Song, Jie; Desphande, Alok S.; Meier, Timothy B.; Tudorascu, Dana L.; Vergun, Svyatoslav; Nair, Veena A.; Biswal, Bharat B.; Meyerand, Mary E.; Birn, Rasmus M.; Bellec, Pierre; Prabhakaran, Vivek

    2012-01-01

    Resting-state functional MRI (rs-fMRI) has emerged as a powerful tool for investigating brain functional connectivity (FC). Research in recent years has focused on assessing the reliability of FC across younger subjects within and between scan-sessions. Test-retest reliability in resting-state functional connectivity (RSFC) has not yet been examined in older adults. In this study, we investigated age-related differences in reliability and stability of RSFC across scans. In addition, we examined how global signal regression (GSR) affects RSFC reliability and stability. Three separate resting-state scans from 29 younger adults (18–35 yrs) and 26 older adults (55–85 yrs) were obtained from the International Consortium for Brain Mapping (ICBM) dataset made publically available as part of the 1000 Functional Connectomes project www.nitrc.org/projects/fcon_1000. 92 regions of interest (ROIs) with 5 cubic mm radius, derived from the default, cingulo-opercular, fronto-parietal and sensorimotor networks, were previously defined based on a recent study. Mean time series were extracted from each of the 92 ROIs from each scan and three matrices of z-transformed correlation coefficients were created for each subject, which were then used for evaluation of multi-scan reliability and stability. The young group showed higher reliability of RSFC than the old group with GSR (p-value = 0.028) and without GSR (p-value <0.001). Both groups showed a high degree of multi-scan stability of RSFC and no significant differences were found between groups. By comparing the test-retest reliability of RSFC with and without GSR across scans, we found significantly higher proportion of reliable connections in both groups without GSR, but decreased stability. Our results suggest that aging is associated with reduced reliability of RSFC which itself is highly stable within-subject across scans for both groups, and that GSR reduces the overall reliability but increases the stability in both

  8. Influence of Prescribed Herbal and Western Medicine on Patients with Abnormal Liver Function Tests: A Retrospective Quasi-Experimental Study

    PubMed Central

    Lee, Ah-Ram; Yim, Je-Min; Kim, Won-Il

    2012-01-01

    Objectives: The aim of this study was to investigate the safety and the efficacy of Korean herbal, western and combination medicine use in patients with abnormal liver function tests. Methods: We investigated nerve disease patients with abnormal liver function tests who were treated with Korean herbal, western and combination medicine at Dong-Eui University Oriental Hospital from January 2011 to August 2011. We compared aspartic aminotransferase (AST), alanine aminotransferase (ALT), alkaline phosphatase (ALP) and total bilirubin (T-bil) levels before and after taking medicine and excluded patients who had liver-related disease when admitted. Results: AST and ALT were decreased significantly in patients who had taken herbal, western medicine. AST, ALT and ALP were decreased significantly in patients who had taken combination medicine. Compare to herbal medicine, AST, ALT and ALP were decreased significantly in patients who had taken western medicine, and ALT and ALP were decreased significantly in patients who had taken combination medicine. There were no significant differences between western and combination medicine. Conclusions: This study suggests that prescribed Korean herbal medicine, at least, does not injure liver function for patients’, moreover, it was shown to be effective in patients with abnormal liver function tests. PMID:25780634

  9. Brief communication: why sleep in a nest? Empirical testing of the function of simple shelters made by wild chimpanzees.

    PubMed

    Stewart, F A

    2011-10-01

    All great apes build nightly a structure ("nest" or "bed") that is assumed to function primarily as a sleeping-platform. However, several other nest function hypotheses have been proposed: antipredation, antipathogen, and thermoregulation. I tested these simple shelter functions of chimpanzee nests in an experiment for which I was the subject in Fongoli, Senegal. I slept 11 nights in chimpanzee nests and on the bare ground to test for differences in sleep quality, potential exposure to disease through bites from possible vectors, and insulation. No difference was found in the total amount of sleep nor in sleep quality; however, sleep was more disturbed on the ground. Differences in sleep disturbance between arboreal and ground conditions seemed primarily due to causes of anxiety and alertness, e.g., vocalizations of terrestrial mammals. Arboreal nest-sleeping seems to reduce risk of bites from possible disease vectors and provide insulation in cold conditions. This preliminary, but direct, test of chimpanzee nest function has implications for the evolutionary transition from limb-roosting to nest-reclining sleep in the hominoids, and from tree-to-ground sleep in the genus Homo. Copyright © 2011 Wiley-Liss, Inc.

  10. Hand reach star excursion balance test: An alternative test for dynamic postural control and functional mobility.

    PubMed

    Eriksrud, Ola; Federolf, Peter; Anderson, Patrick; Cabri, Jan

    2018-01-01

    Tests of dynamic postural control eliciting full-body three-dimensional joint movements in a systematic manner are scarce. The well-established star excursion balance test (SEBT) elicits primarily three-dimensional lower extremity joint movements with minimal trunk and no upper extremity joint movements. In response to these shortcomings we created the hand reach star excursion balance test (HSEBT) based on the SEBT reach directions. The aims of the current study were to 1) compare HSEBT and SEBT measurements, 2) compare joint movements elicited by the HSEBT to both SEBT joint movements and normative range of motion values published in the literature. Ten SEBT and HSEBT reaches for each foot were obtained while capturing full-body kinematics in twenty recreationally active healthy male subjects. HSEBT and SEBT areas and composite scores (sum of reaches) for total, anterior and posterior subsections and individual reaches were correlated. Total reach score comparisons showed fair to moderate correlations (r = .393 to .606), while anterior and posterior subsections comparisons had fair to good correlations (r = .269 to .823). Individual reach comparisons had no to good correlations (r = -.182 to .822) where lateral and posterior reaches demonstrated the lowest correlations (r = -.182 to .510). The HSEBT elicited more and significantly greater joint movements than the SEBT, except for hip external rotation, knee extension and plantarflexion. Comparisons to normative range of motion values showed that 3 of 18 for the SEBT and 8 of 22 joint movements for the HSEBT were within normative values. The findings suggest that the HSEBT can be used for the assessment of dynamic postural control and is particularly suitable for examining full-body functional mobility.

  11. Estimation of automobile-driver describing function from highway tests using the double steering wheel

    NASA Technical Reports Server (NTRS)

    Delp, P.; Crossman, E. R. F. W.; Szostak, H.

    1972-01-01

    The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.

  12. Effect of Septorhinoplasty on Olfactory Function: Assessment Using the Brief Smell Identification Test.

    PubMed

    Dengiz, Ramazan; Haytoğlu, Süheyl; Görgülü, Orhan; Doğru, Mehmet; Arıkan, Osman Kürşat

    2015-03-01

    Septorhinoplasty (SRP), one of the most commonly performed rhinologic surgery procedures, can affect olfactory function; however, the findings of studies investigating smell following SRP are controversial. We used a culturally adapted modified Brief Smell Identification Test (B-SIT) to investigate the long- and short-term effects of SRP on olfactory function. We enrolled 59 patients admitted to the Ear-Nose-Throat Clinic, who were complaining of external nasal deformity and nasal obstruction. Functional SRP was performed on all cases. The B-SIT was administered prior to surgery and at 4 and 12 weeks post-surgery. The smell identification score (SIS) reflected the number of correct answers. In addition, we investigated the effects of gender and smoking on olfactory function and whether the SRP procedure changed these associations. The mean preoperative, 4-week, and 12-week postoperative SISs were 10.15±1.30, 10.21±1.52, and 10.92±0.95, respectively. The difference between the preoperative and 4-week postoperative SISs was not statistically significant; however, the 12-week postoperative score was significantly different from the preoperative and 4-week postoperative scores. Furthermore, the repeated measures analysis according to gender and smoking habit revealed a significant difference between the 4-and 12-week postoperative SISs. One patient developed postoperative anosmia; however, the patient recovered in the 12-week postoperative period. SRP surgery is a safe procedure in terms of olfactory function. In addition, olfactory function may increase following surgery as a result of improved nasal airflow.

  13. Test report: Electron-proton spectrometer qualification test unit, qualification test

    NASA Technical Reports Server (NTRS)

    Vincent, D. L.

    1972-01-01

    Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.

  14. Can the calf-raise senior test predict functional fitness in elderly people? A validation study using electromyography, kinematics and strength tests.

    PubMed

    André, Helô-Isa; Carnide, Filomena; Moço, Andreia; Valamatos, Maria-João; Ramalho, Fátima; Santos-Rocha, Rita; Veloso, António

    2018-06-05

    The assessment of the plantar-flexors muscle strength in older adults (OA) is of the utmost importance since they are strongly associated with the performance of fundamental tasks of daily life. The objective was to strengthen the validity of the Calf-Raise-Senior (CRS) test by assessing the biomechanical movement pattern of calf muscles in OA with different levels of functional fitness (FF) and physical activity (PA). Twenty-six OA were assessed with CRS, a FF battery, accelerometry, strength tests, kinematics and electromyography (EMG). OA with the best and worst CRS scores were compared. The association between the scores and EMG pattern of ankle muscles was determined. OA with the best CRS scores presented higher levels of FF, PA, strength, power, speed and range of movement, and a more efficient movement pattern during the test. Subjects who scored more at the CRS test demonstrated the possibility to use a stretch-shortening cycle type of action in the PF muscles to increase power during the movements. OA with different levels of FF can be stratified by the muscular activation pattern of the calf muscles and the scores in CRS test. This study reinforced the validity of CRS for evaluating ankle strength and power in OA. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Latent Class Analysis of Differential Item Functioning on the Peabody Picture Vocabulary Test-III

    ERIC Educational Resources Information Center

    Webb, Mi-young Lee; Cohen, Allan S.; Schwanenflugel, Paula J.

    2008-01-01

    This study investigated the use of latent class analysis for the detection of differences in item functioning on the Peabody Picture Vocabulary Test-Third Edition (PPVT-III). A two-class solution for a latent class model appeared to be defined in part by ability because Class 1 was lower in ability than Class 2 on both the PPVT-III and the…

  16. Clinical utility of balloon expulsion test for functional defecation disorders

    PubMed Central

    2016-01-01

    Purpose I investigated the diagnostic accuracy of balloon expulsion test (BET) with various techniques to find out the most appropriate method, and tried to confirm its clinical utility in diagnosing functional defecation disorders (FDD) in constipated patients. Methods Eighty-seven patients constituted the study population. FDD was defined when patients had at least two positive findings in defecography, manometry, and electromyography. BET was done 4 times in each patient with 2 different positions and 2 different volumes. The positions were seated position (SP) and left lateral decubitus position (LDP). The volumes were fixed volume (FV) of 60 mL and individualized volume with which patient felt a constant desire to defecate (CDV). The results of BETs with 4 different settings (LDP-FV, LDP-CDV, SP-FV, and SP-CDV) were statistically compared and analyzed. Results Of 87 patients, 23 patients (26.4%) had at least two positive findings in 3 tests and thus were diagnosed to have FDD. On receiver operating characteristic curve analysis, area under curve was highest in BET with SP-FV. With a cutoff value of 30 seconds, the specificity of BET with SP-FV was 86.0%, sensitivity was 73.9%, negative predictive value was 89.8%, positive predictive value was 65.4%, and accuracy rate was 82.8% for diagnosing FDD. Conclusion SP-FV is the most appropriate method for BET. In this setting, BET has a diagnostic accuracy sufficient to identify constipated patients who do not have FDD. Patients with negative results in BET with SP-FV may not need other onerous tests to exclude FDD. PMID:26878016

  17. Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players.

    PubMed

    Kea, J; Kramer, J; Forwell, L; Birmingham, T

    2001-08-01

    Single group, test-retest. To determine: (1) hip abduction and adduction torques during concentric and eccentric muscle actions, (2) medial and lateral one-leg hop distances, (3) the test-retest reliability of these measurements, and (4) the relationship between isokinetic measures of hip muscle strength and hop distances in elite ice hockey players. The skating motion used in ice hockey requires strong contractions of the hip and knee musculature. However, baseline scores for hip strength and hop distances, their test-retest reliability, and measures of the extent to which these tests are related for this population are not available. The dominant leg of 27 men (mean age 20 +/- 3 yrs) was tested on 2 occasions. Hip abduction and adduction movements were completed at 60 degrees.s(-1) angular velocity, with the subject lying on the non-test side and the test leg moving vertically in the subject's coronal plane. One-leg hops requiring jumping from and landing on the same leg without losing balance were completed in the medial and lateral directions. Hip adduction torques were significantly greater than abduction torques during both concentric and eccentric muscle actions, while no significant difference was observed between medial and lateral hop distances. Although hop test scores produced excellent ICCs (> 0.75) when determined using scores on 1 occasion, torques needed to be averaged over 2 test occasions to reach this level. Correlations between the strength and hop tests ranged from slight to low (r = -0.26 to 0.27) and were characterized by wide 95% confidence intervals (-0.54 to 0.61). Isokinetic tests of hip abduction and adduction did not provide a strong indication of performance during sideways hop tests. Although isokinetic tests can provide a measure of muscular strength under specific test conditions, they should not be relied upon as a primary indicator of functional abilities or readiness to return to activity.

  18. Genetic mouse embryo assay: improving performance and quality testing for assisted reproductive technology (ART) with a functional bioassay.

    PubMed

    Gilbert, Rebecca S; Nunez, Brandy; Sakurai, Kumi; Fielder, Thomas; Ni, Hsiao-Tzu

    2016-03-24

    Growing concerns about safety of ART on human gametes, embryos, clinical outcomes and long-term health of offspring require improved methods of risk assessment to provide functionally relevant assays for quality control testing and pre-clinical studies prior to clinical implementation. The one-cell mouse embryo assay (MEA) is the most widely used for development and quality testing of human ART products; however, concerns exist due to the insensitivity/variability of this bioassay which lacks standardization and involves subjective analysis by morphology alone rather than functional analysis of the developing embryos. We hypothesized that improvements to MEA by the use of functional molecular biomarkers could enhance sensitivity and improve detection of suboptimal materials/conditions. Fresh one-cell transgenic mouse embryos with green fluorescent protein (GFP) expression driven by Pou6f1 or Cdx2 control elements were harvested and cultured to blastocysts in varied test and control conditions to compare assessment by standard morphology alone versus the added dynamic expression of GFP for screening and selection of critical raw materials and detection of suboptimal culture conditions. Transgenic mouse embryos expressing functionally relevant biomarkers of normal early embryo development can be used to monitor the developmental impact of culture conditions. This novel approach provides a superior MEA that is more meaningful and sensitive for detection of embryotoxicity than morphological assessment alone.

  19. Graph Theoretical Analysis of Functional Brain Networks: Test-Retest Evaluation on Short- and Long-Term Resting-State Functional MRI Data

    PubMed Central

    Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong

    2011-01-01

    Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (<1 hour apart) and long-term (>5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285

  20. Enzymatic liver function capacity correlates with disease severity of patients with liver cirrhosis: a study with the LiMAx test.

    PubMed

    Malinowski, Maciej; Jara, Maximilian; Lüttgert, Katja; Orr, James; Lock, Johan Friso; Schott, Eckart; Stockmann, Martin

    2014-12-01

    Assessment and quantification of actual liver function is crucial in patients with chronic liver disease to monitor disease progression and predict individual prognosis. Mathematical models, such as model for end-stage liver disease, are used for risk stratification of patients with chronic liver disease but do not include parameters that reflect the actual functional state of the liver. We aimed to evaluate the potential of a (13)C-based liver function test as a stratification tool by comparison with other liver function tests and clinical parameters in a large sample of healthy controls and cirrhotic patients. We applied maximum liver function capacity (LiMAx) to evaluate actual liver function in 347 patients with cirrhosis and in 86 controls. LiMAx showed strong negative correlation with Child-Pugh Score (r = -0.707; p < 0.001), MELD (r = -0.686; p < 0.001) and liver function tests. LiMAx was lower in patients with liver cirrhosis compared to healthy controls [99 (57-160) µg/kg/h vs. 412 (365-479) µg/kg/h, p < 0.001] and differed among Child-Pugh classes [a: 181 (144-227) µg/kg/h, b: 96 (62-132) µg/kg/h and c: 52 (37-81) µg/kg/h; p < 0.001]. When stratified patients according to disease severity, LiMAx results were not different between cirrhotic patients and cirrhotic patients with transjugular intrahepatic portosystemic shunt. LiMAx appears to provide reliable information on remnant enzymatic liver function in chronic liver disease and allows graduation of disease severity.

  1. Validation of PROMIS ® Physical Function computerized adaptive tests for orthopaedic foot and ankle outcome research.

    PubMed

    Hung, Man; Baumhauer, Judith F; Latt, L Daniel; Saltzman, Charles L; SooHoo, Nelson F; Hunt, Kenneth J

    2013-11-01

    In 2012, the American Orthopaedic Foot & Ankle Society(®) established a national network for collecting and sharing data on treatment outcomes and improving patient care. One of the network's initiatives is to explore the use of computerized adaptive tests (CATs) for patient-level outcome reporting. We determined whether the CAT from the NIH Patient Reported Outcome Measurement Information System(®) (PROMIS(®)) Physical Function (PF) item bank provides efficient, reliable, valid, precise, and adequately covered point estimates of patients' physical function. After informed consent, 288 patients with a mean age of 51 years (range, 18-81 years) undergoing surgery for common foot and ankle problems completed a web-based questionnaire. Efficiency was determined by time for test administration. Reliability was assessed with person and item reliability estimates. Validity evaluation included content validity from expert review and construct validity measured against the PROMIS(®) Pain CAT and patient responses based on tradeoff perceptions. Precision was assessed by standard error of measurement (SEM) across patients' physical function levels. Instrument coverage was based on a person-item map. Average time of test administration was 47 seconds. Reliability was 0.96 for person and 0.99 for item. Construct validity against the Pain CAT had an r value of -0.657 (p < 0.001). Precision had an SEM of less than 3.3 (equivalent to a Cronbach's alpha of ≥ 0.90) across a broad range of function. Concerning coverage, the ceiling effect was 0.32% and there was no floor effect. The PROMIS(®) PF CAT appears to be an excellent method for measuring outcomes for patients with foot and ankle surgery. Further validation of the PROMIS(®) item banks may ultimately provide a valid and reliable tool for measuring patient-reported outcomes after injuries and treatment.

  2. Ability of walking without a walking device in patients with spinal cord injury as determined using data from functional tests

    PubMed Central

    Poncumhak, Puttipong; Saengsuwan, Jiamjit; Amatachaya, Sugalya

    2014-01-01

    Background/Objectives More than half of independent ambulatory patients with spinal cord injury (SCI) need a walking device to promote levels of independence. However, long-lasting use of a walking device may introduce negative impacts for the patients. Using a standard objective test relating to the requirement of a walking device may offer a quantitative criterion to effectively monitor levels of independence of the patients. Therefore, this study investigated (1) ability of the three functional tests, including the five times sit-to-stand test (FTSST), timed up and go test (TUGT), and 10-meter walk test (10MWT) to determine the ability of walking without a walking device, and (2) the inter-tester reliability of the tests to assess functional ability in patients with SCI. Methods Sixty independent ambulatory patients with SCI, who walked with and without a walking device (30 subjects/group), were assessed cross-sectionally for their functional ability using the three tests. The first 20 subjects also participated in the inter-tester reliability test. Results The time required to complete the FTSST <14 seconds, the TUGT < 18 seconds, and the 10MWT < 6 seconds had good-to-excellent capability to determine the ability of walking without a walking device of subjects with SCI. These tests also showed excellent inter-tester reliability. Conclusions Methods of clinical evaluation for walking are likely performed using qualitative observation, which makes the results difficult to compare among testers and test intervals. Findings of this study offer a quantitative target criterion or a clear level of ability that patients with SCI could possibly walk without a walking device, which would benefit monitoring process for the patients. PMID:24621030

  3. Hypersonic Research Vehicle (HRV) real-time flight test support feasibility and requirements study. Part 2: Remote computation support for flight systems functions

    NASA Technical Reports Server (NTRS)

    Rediess, Herman A.; Hewett, M. D.

    1991-01-01

    The requirements are assessed for the use of remote computation to support HRV flight testing. First, remote computational requirements were developed to support functions that will eventually be performed onboard operational vehicles of this type. These functions which either cannot be performed onboard in the time frame of initial HRV flight test programs because the technology of airborne computers will not be sufficiently advanced to support the computational loads required, or it is not desirable to perform the functions onboard in the flight test program for other reasons. Second, remote computational support either required or highly desirable to conduct flight testing itself was addressed. The use is proposed of an Automated Flight Management System which is described in conceptual detail. Third, autonomous operations is discussed and finally, unmanned operations.

  4. Investigating Linguistic Sources of Differential Item Functioning Using Expert Think-Aloud Protocols in Science Achievement Tests

    NASA Astrophysics Data System (ADS)

    Roth, Wolff-Michael; Oliveri, Maria Elena; Dallie Sandilands, Debra; Lyons-Thomas, Juliette; Ercikan, Kadriye

    2013-03-01

    Even if national and international assessments are designed to be comparable, subsequent psychometric analyses often reveal differential item functioning (DIF). Central to achieving comparability is to examine the presence of DIF, and if DIF is found, to investigate its sources to ensure differentially functioning items that do not lead to bias. In this study, sources of DIF were examined using think-aloud protocols. The think-aloud protocols of expert reviewers were conducted for comparing the English and French versions of 40 items previously identified as DIF (N = 20) and non-DIF (N = 20). Three highly trained and experienced experts in verifying and accepting/rejecting multi-lingual versions of curriculum and testing materials for government purposes participated in this study. Although there is a considerable amount of agreement in the identification of differentially functioning items, experts do not consistently identify and distinguish DIF and non-DIF items. Our analyses of the think-aloud protocols identified particular linguistic, general pedagogical, content-related, and cognitive factors related to sources of DIF. Implications are provided for the process of arriving at the identification of DIF, prior to the actual administration of tests at national and international levels.

  5. Functional connectivity during phonemic and semantic verbal fluency test: a multi-channel near infrared spectroscopy study (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Huang, Chun-Jung; Sun, Chia-Wei; Chou, Po-Han; Chuang, Ching-Cheng

    2016-03-01

    Verbal fluency tests (VFT) are widely used neuropsychological tests of frontal lobe and have been frequently used in various functional brain mapping studies. There are two versions of VFT based on the type of cue: the letter fluency task (LFT) and the category fluency task (CFT). However, the fundamental aspect of the brain connectivity across spatial regions of the fronto-temporal regions during the VFTs has not been elucidated to date. In this study we hypothesized that different cortical functional connectivity over bilateral fronto-temporal regions can be observed by means of multi-channel fNIRS in the LFT and the CFT respectively. Our results from fNIRS (ETG-4000) showed different patterns of brain functional connectivity consistent with these different cognitive requirements. We demonstrate more brain functional connectivity over frontal and temporal regions during LFT than CFT, and this was in line with previous brain activity studies using fNIRS demonstrating increased frontal and temporal region activation during LFT and CFT and more pronounced frontal activation by the LFT.

  6. ROC and Loss Function Analysis in Sequential Testing

    ERIC Educational Resources Information Center

    Muijtjens, Arno M. M.; Van Luijk, Scheltus J.; Van Der Vleuten, Cees P. M.

    2006-01-01

    Sequential testing is applied to reduce costs in SP-based tests (OSCEs). Initially, all candidates take a screening test consisting of a part of the OSCE. Candidates who fail the screen sit the complete test, whereas those who pass the screen are qualified as a pass of the complete test. The procedure may result in a reduction of testing…

  7. Should patients with abnormal liver function tests in primary care be tested for chronic viral hepatitis: cost minimisation analysis based on a comprehensively tested cohort.

    PubMed

    Arnold, David T; Bentham, Louise M; Jacob, Ruth P; Lilford, Richard J; Girling, Alan J

    2011-03-03

    Liver function tests (LFTs) are ordered in large numbers in primary care, and the Birmingham and Lambeth Liver Evaluation Testing Strategies (BALLETS) study was set up to assess their usefulness in patients with no pre-existing or self-evident liver disease. All patients were tested for chronic viral hepatitis thereby providing an opportunity to compare various strategies for detection of this serious treatable disease. This study uses data from the BALLETS cohort to compare various testing strategies for viral hepatitis in patients who had received an abnormal LFT result. The aim was to inform a strategy for identification of patients with chronic viral hepatitis. We used a cost-minimisation analysis to define a base case and then calculated the incremental cost per case detected to inform a strategy that could guide testing for chronic viral hepatitis. Of the 1,236 study patients with an abnormal LFT, 13 had chronic viral hepatitis (nine hepatitis B and four hepatitis C). The strategy advocated by the current guidelines (repeating the LFT with a view to testing for specific disease if it remained abnormal) was less efficient (more expensive per case detected) than a simple policy of testing all patients for viral hepatitis without repeating LFTs. A more selective strategy of viral testing all patients for viral hepatitis if they were born in countries where viral hepatitis was prevalent provided high efficiency with little loss of sensitivity. A notably high alanine aminotransferase (ALT) level (greater than twice the upper limit of normal) on the initial ALT test had high predictive value, but was insensitive, missing half the cases of viral infection. Based on this analysis and on widely accepted clinical principles, a "fast and frugal" heuristic was produced to guide general practitioners with respect to diagnosing cases of viral hepatitis in asymptomatic patients with abnormal LFTs. It recommends testing all patients where a clear clinical indication of

  8. Functional redundancy as a tool for bioassessment: A test using riparian vegetation.

    PubMed

    Bruno, D; Gutiérrez-Cánovas, C; Velasco, J; Sánchez-Fernández, D

    2016-10-01

    There is an urgent need to track how natural systems are responding to global change in order to better guide management efforts. Traditionally, taxonomically based metrics have been used as indicators of ecosystem integrity and conservation status. However, functional approaches offer promising advantages that can improve bioassessment performance. In this study, we aim to test the applicability of functional redundancy (FR), a functional feature related to the stability, resistance and resilience of ecosystems, as a tool for bioassessment, looking at woody riparian communities in particular. We used linear mixed-effect models to investigate the response of FR and other traditional biomonitoring indices to natural (drought duration) and anthropogenic stress gradients (flow regulation and agriculture) in a Mediterranean basin. Such indices include species richness, a taxonomic index, and the Riparian Quality Index, which is an index of ecological status. Then, we explored the ability of FR and the other indices to discriminate between different intensities of human alteration. FR showed higher explanatory capacity in response to multiple stressors, although we found significant negative relationships between all the biological indices (taxonomic, functional and ecological quality) and stress gradients. In addition, FR was the most accurate index to discriminate among different categories of human alteration in both perennial and intermittent river reaches, which allowed us to set threshold values to identify undisturbed (reference condition), moderately disturbed and highly disturbed reaches in the two types of river. Using these thresholds and the best-fitting model, we generated a map of human impact on the functional redundancy of riparian communities for all the stretches of the river network. Our results demonstrate that FR presents clear advantages over traditional methods, which suggests that it should be part of the biomonitoring toolbox used for

  9. One minute sit-to-stand test is an alternative to 6MWT to measure functional exercise performance in COPD patients.

    PubMed

    Reychler, Gregory; Boucard, Eliott; Peran, Loïc; Pichon, Romain; Le Ber-Moy, Catherine; Ouksel, Hakima; Liistro, Giuseppe; Chambellan, Arnaud; Beaumont, Marc

    2018-03-01

    Chronic obstructive pulmonary disease (COPD) is frequently associated with a reduced functional exercise performance. Even if this parameter is routinely evaluated using 6-minute walking test (6MWT), new field tests are regularly investigated as alternative tests. The aim of this study was to compare functional exercise performance evaluation by sit-to-stand test (STST) and 6MWT and to evaluate reliability and repeatability of the STST in COPD patients. Forty-two COPD patients performed randomly two tests: 6MWT and STST. Each test was repeated two times. Distance (6MWD) and number of repetitions were measured. Cardiorespiratory parameters, dyspnea and lower limb fatigue (Borg) were recorded before and after the tests. Sit-to-stand repetitions (19 ± 6) and 6MWD (441 ± 104 m) were correlated (r = .716; P < .001). Good repeatability was found for STST and 6MWT. Good reliability was observed for STST (ICC = 0.902). Variations of heart rate and pulsed oxygen saturation were significantly different between these two tests (23% ± 17% vs 13% ± 11%; P = .022 and -7.6% ± 4.6% vs -0.7% ± 2.7%; P < .001 for 6MWT and STST, respectively). Variations of dyspnea and lower limb fatigue were similar between both tests (P = .827 and P = .467). The one minute sit-to-stand test is a valuable alternative to 6MWT to estimate functional exercise performance in COPD patients. The cardiorespiratory demand is different between both tests although the variation of dypsnea is similar. No learning effect was observed for STST. © 2017 John Wiley & Sons Ltd.

  10. 49 CFR 40.129 - What are the MRO's functions in reviewing laboratory confirmed non-negative drug test results?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What are the MRO's functions in reviewing laboratory confirmed non-negative drug test results? 40.129 Section 40.129 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification Proces...

  11. Near-infrared spectroscopic study and the Wada test for presurgical evaluation of expressive and receptive language functions in glioma patients: with a case report of dissociated language functions.

    PubMed

    Sato, Yosuke; Uzuka, Takeo; Aoki, Hiroshi; Natsumeda, Manabu; Oishi, Makoto; Fukuda, Masafumi; Fujii, Yukihiko

    2012-02-29

    Near-infrared spectroscopy (NIRS) has proven to be useful for the evaluation of language lateralization in healthy subjects, infants, and epileptic patients. This study for the first time investigated the expressive and receptive language functions separately, using NIRS in presurgical glioma patients. We also describe a special case with dissociated pattern of language functions. Ten glioma patients were examined. Using NIRS, the hemodynamic changes during a verb generation task or story listening task were measured in the cerebral hemisphere on either side covering the language areas. Following the NIRS study, the Wada test was performed in all the patients. The NIRS study revealed increases of oxyhemoglobin and decreases of deoxyhemoglobin in the language areas elicited by both tasks. In 9 patients, who were all right-handed, the expressive and receptive language functions were lateralized to the left hemisphere. The results of the NIRS study were completely consistent with those of the Wada test. In the remaining 1 patient with a right sided insular glioma, who was right-handed, the NIRS study revealed stronger activation of the right inferior frontal region during the verb generation task, and stronger activation of the left superior temporal region during the story listening task. This dissociated language function was validated by the Wada test and the postoperative neurological course. These results demonstrate that a NIRS study using our technique is extremely valuable for preoperative assessment of the language functions and exemplifies how a preoperative NIRS study can allow detection of unforeseen language lateralization. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. How Do Executive Functions Fit with the Cattell-Horn-Carroll Model? Some Evidence from a Joint Factor Analysis of the Delis-Kaplan Executive Function System and the Woodcock-Johnson III Tests of Cognitive Abilities

    ERIC Educational Resources Information Center

    Floyd, Randy G.; Bergeron, Renee; Hamilton, Gloria; Parra, Gilbert R.

    2010-01-01

    This study investigated the relations among executive functions and cognitive abilities through a joint exploratory factor analysis and joint confirmatory factor analysis of 25 test scores from the Delis-Kaplan Executive Function System and the Woodcock-Johnson III Tests of Cognitive Abilities. Participants were 100 children and adolescents…

  13. Evaluation of a role functioning computer adaptive test (RF-CAT).

    PubMed

    Anatchkova, M; Rose, M; Ware, J; Bjorner, J B

    2013-06-01

    To evaluate the validity and participants' acceptance of an online assessment of role function using computer adaptive test (RF-CAT). The RF-CAT and a set of established quality of life instruments were administered in a cross-sectional study in a panel sample (n = 444) recruited from the general population with over-selection of participants with selected self-report chronic conditions (n = 225). The efficiency, score accuracy, validity, and acceptability of the RF-CAT were evaluated and compared to existing measures. The RF-CAT with a stopping rule of six items with content balancing used 25 of the available bank items and was completed on average in 66 s. RF-CAT and the legacy tools scores were highly correlated (.64-.84) and successfully discriminated across known groups. The RF-CAT produced a more precise assessment over a wider range than the SF-36 Role Physical scale. Patients' evaluations of the RF-CAT system were positive overall, with no differences in ratings observed between the CAT and static assessments. The RF-CAT was feasible, more precise than the static SF-36 RP and equally acceptable to participants as legacy measures. In empirical tests of validity, the better performance of the CAT was not uniformly statistically significant. Further research exploring the relationship between gained precision and discriminant power of the CAT assessment is needed.

  14. A versatile test for equality of two survival functions based on weighted differences of Kaplan-Meier curves.

    PubMed

    Uno, Hajime; Tian, Lu; Claggett, Brian; Wei, L J

    2015-12-10

    With censored event time observations, the logrank test is the most popular tool for testing the equality of two underlying survival distributions. Although this test is asymptotically distribution free, it may not be powerful when the proportional hazards assumption is violated. Various other novel testing procedures have been proposed, which generally are derived by assuming a class of specific alternative hypotheses with respect to the hazard functions. The test considered by Pepe and Fleming (1989) is based on a linear combination of weighted differences of the two Kaplan-Meier curves over time and is a natural tool to assess the difference of two survival functions directly. In this article, we take a similar approach but choose weights that are proportional to the observed standardized difference of the estimated survival curves at each time point. The new proposal automatically makes weighting adjustments empirically. The new test statistic is aimed at a one-sided general alternative hypothesis and is distributed with a short right tail under the null hypothesis but with a heavy tail under the alternative. The results from extensive numerical studies demonstrate that the new procedure performs well under various general alternatives with a caution of a minor inflation of the type I error rate when the sample size is small or the number of observed events is small. The survival data from a recent cancer comparative study are utilized for illustrating the implementation of the process. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Pressure chamber tests of eustachian tube function document lower efficiency in adults with colds when compared to without colds.

    PubMed

    Doyle, William J; Singla, Alok; Banks, Juliane; El-Wagaa, Jenna; Swarts, J Douglas

    2014-07-01

    Fractional gradient equilibrated (FGE) for ears with applied positive but not negative middle ear (ME)-ambient pressure gradients is highly sensitive to a cold-like illness (CLI). The sequential development of eustachian tube (ET) dysfunction, ME under-pressure, and otitis media (OM) characterizes many children during a CLI. If linked, OM burden would be lessened by interventions that promote/preserve good ET function during a CLI. Evaluating this requires a quantitative ET function test for MEs with an intact tympanic membrane responsive to a CLI. Pressure chamber testing of ET function was performed at +200 and -200 daPa in 3 groups of adults: group I, 21 subjects with an extant CLI and groups II and III, 14 and 57 adults, respectively, without a CLI. ME-chamber pressure gradient was recorded by tympanometry before and after the subject swallowed twice. ET functional efficiency was quantified as the FGE, which was then compared among groups using a Mann-Whitney U test. At chamber pressures of 200 daPa, the ME-chamber pressure gradient was negative, and FGE was low and not different among groups. At chamber pressures of -200 daPa that gradient was positive, and FGE was significantly higher in groups II and III when compared with group I.

  16. Ecosystem functioning and maximum entropy production: a quantitative test of hypotheses.

    PubMed

    Meysman, Filip J R; Bruers, Stijn

    2010-05-12

    The idea that entropy production puts a constraint on ecosystem functioning is quite popular in ecological thermodynamics. Yet, until now, such claims have received little quantitative verification. Here, we examine three 'entropy production' hypotheses that have been forwarded in the past. The first states that increased entropy production serves as a fingerprint of living systems. The other two hypotheses invoke stronger constraints. The state selection hypothesis states that when a system can attain multiple steady states, the stable state will show the highest entropy production rate. The gradient response principle requires that when the thermodynamic gradient increases, the system's new stable state should always be accompanied by a higher entropy production rate. We test these three hypotheses by applying them to a set of conventional food web models. Each time, we calculate the entropy production rate associated with the stable state of the ecosystem. This analysis shows that the first hypothesis holds for all the food webs tested: the living state shows always an increased entropy production over the abiotic state. In contrast, the state selection and gradient response hypotheses break down when the food web incorporates more than one trophic level, indicating that they are not generally valid.

  17. Demonstration of the test-retest reliability and sensitivity of the Lower Limb Functional Index-10 as a measure of functional recovery post burn injury: a cross-sectional repeated measures study design.

    PubMed

    Ryland, Margaret E; Grisbrook, Tiffany L; Wood, Fiona M; Phillips, Michael; Edgar, Dale W

    2016-01-01

    Lower limb burns can significantly delay recovery of function. Measuring lower limb functional outcomes is challenging in the unique burn patient population and necessitates the use of reliable and valid tools. The aims of this study were to examine the test-retest reliability, sensitivity, and internal consistency of Sections 1 and 3 of the Lower Limb Functional Index-10 (LLFI-10) questionnaire for measuring functional ability in patients with lower limb burns over time. Twenty-nine adult patients who had sustained a lower limb burn injury in the previous 12 months completed the test-retest procedure of the study. In addition, the minimal detectable change (MDC) was calculated for Section 1 and 3 of the LLFI-10. Section 1 is focused on the activity limitations experienced by patients with a lower limb disorder whereas Section 3 involves patients indicating their current percentage of pre-injury duties. Section 1 of the LLFI-10 demonstrated excellent test-retest reliability (intra-class correlation coefficient (ICC) 0.98, 95 % CI 0.96-0.99) whilst Section 3 demonstrated high test-retest reliability (ICC 0.88, 95 % CI 0.79-0.94). MDC scores for Sections 1 and 3 were 1.27 points and 30.22 %, respectively. Internal consistency was demonstrated with a significant negative association (r s  = -0.83) between Sections 1 and 3 of the LLFI-10 (p < 0.001). This study demonstrates that Section 1 and 3 of the LLFI-10 are reliable for measuring functional ability in patients who have sustained lower limb burns in the previous 12 months, and furthermore, Section 1 is sensitive to changes in patient function over time.

  18. Comparison of effects of dry versus wet swallowing on Eustachian tube function via a nine-step inflation/deflation test.

    PubMed

    Adali, M Kemal; Uzun, Cem

    2005-09-01

    The aim of the present study is to evaluate the effect of swallowing type (dry versus wet) on the outcome of a nine-step inflation/deflation tympanometric Eustachian tube function (ETF) test in healthy adults. Fourteen normal healthy volunteers, between 19 and 28 years of age, were included in the study. The nine-step test was performed in two different test procedures: (1) test with dry swallows (dry test procedure) and (2) test with liquid swallows (wet test procedure). If the equilibration of middle-ear (ME) pressure was successful in all the steps of the nine-step test, ETF was considered 'Good'. Otherwise, the test was considered 'Poor', and the test was repeated at a second session. In the dry test procedure, ETF was 'Good' in 21 ears at the first session and in 24 ears after the second session (p > 0.05). However, in the wet test procedure, ETF was 'Good' in 13 ears at the first session and in 21 ears after the second session (p < 0.05). At the first session, ETF was 'Good' in 21 and 13 ears in the dry and wet test procedures, respectively. The difference was statistically significant (p < 0.05). However, after the second session, the overall number of ears with 'Good' tubal function was almost the same in both test procedures (24 ears at dry test procedures versus 21 ears at wet test procedures;p > 0.05). Dry swallowing seems to be more effective for the equilibration of ME pressure. Thus, a single-session dependent evaluation of ETF may be efficient for the dry test procedure of the nine-step test. Swallowing with water may be easier for subjects, but a repetition of the test at a second session may be necessary when the test result is 'Poor'.

  19. 20 CFR 718.103 - Pulmonary function tests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...

  20. 20 CFR 718.103 - Pulmonary function tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...

  1. 20 CFR 718.103 - Pulmonary function tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...

  2. 20 CFR 718.103 - Pulmonary function tests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...

  3. 20 CFR 718.103 - Pulmonary function tests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...

  4. Experimental testing of Mackay's model for functional antagonism in the isolated costo-uterus of the rat.

    PubMed Central

    Henry, P. J.; Lulich, K. M.; Paterson, J. W.

    1985-01-01

    Several key predictions of a recently developed model for functional antagonism (Mackay, 1981) were experimentally tested using the rat isolated costo-uterine preparation. In the presence of the functional antagonist fenoterol (Fen), the functional constants (KAF) for carbachol and oxotremorine (Oxo) were respectively 9.9 and 3.4 fold greater than their corresponding affinity constants (KA). According to Mackay's model for functional antagonism, the higher KAF/KA ratio for carbachol indicates that this cholinoceptor agonist has a greater efficacy than Oxo. This was confirmed by using conventional pharmacological methods. As predicted from the model of functional antagonism, the plot of KAF/KA-1 against the fraction of cholinoceptors not irreversibly blocked by phenoxybenzamine (Pbz) was linear for both carbachol and Oxo and the lines of best fit crossed the axes at a point not significantly different from the origin. The value of 4.6 for the relative efficacy of carbachol to Oxo estimated from functional antagonism studies was comparable to the value of 5.6 calculated using the method of irreversible antagonism proposed by Furchgott (1966). PMID:3840396

  5. The Glittre-ADL Test Cut-Off Point to Discriminate Abnormal Functional Capacity in Patients with COPD.

    PubMed

    Gulart, Aline Almeida; Munari, Anelise Bauer; Klein, Suelen Roberta; Santos da Silveira, Lucas; Mayer, Anamaria Fleig

    2018-02-01

    The study objective was to determine a cut-off point for the Glittre activities of daily living (ADL)test (TGlittre) to discriminate patients with normal and abnormal functional capacity. Fifty-nine patients with moderate to very severe COPD (45 males; 65 ± 8.84 years; BMI: 26 ± 4.78 kg/m 2 ; FEV 1 : 35.3 ± 13.4% pred) were evaluated for spirometry, TGlittre, 6-minute walk test (6 MWT), physical ADL, modified Medical Research Council scale (mMRC), BODE index, Saint George's Respiratory Questionnaire (SGRQ), and COPD Assessment Test (CAT). The receiver operating characteristic (ROC) curve was used to determine the cut-off point for TGlittre in order to discriminate patients with 6 MWT < 82% pred. The ROC curve indicated a cut-off point of 3.5 minutes for the TGlittre (sensitivity = 92%, specificity = 83%, and area under the ROC curve = 0.95 [95% CI: 0.89-0.99]). Patients with abnormal functional capacity had higher mMRC (median difference 1 point), CAT (mean difference: 4.5 points), SGRQ (mean difference: 12.1 points), and BODE (1.37 points) scores, longer time of physical activity <1.5 metabolic equivalent of task (mean difference: 47.9 minutes) and in sitting position (mean difference: 59.4 minutes) and smaller number of steps (mean difference: 1,549 minutes); p < 0.05 for all. In conclusion, the cut-off point of 3.5 minutes in the TGlittre is sensitive and specific to distinguish COPD patients with abnormal and normal functional capacity.

  6. Dichotic listening tests of functional brain asymmetry predict response to fluoxetine in depressed women and men.

    PubMed

    Bruder, Gerard E; Stewart, Jonathan W; McGrath, Patrick J; Deliyannides, Deborah; Quitkin, Frederic M

    2004-09-01

    Patients having a depressive disorder vary widely in their therapeutic responsiveness to a selective serotonin reuptake inhibitor (SSRI), but there are no clinical predictors of treatment outcome. Studies using dichotic listening, electrophysiologic and neuroimaging measures suggest that pretreatment differences among depressed patients in functional brain asymmetry are related to responsiveness to antidepressants. Two new studies replicate differences in dichotic listening asymmetry between fluoxetine responders and nonresponders, and demonstrate the importance of gender in this context. Right-handed outpatients who met DSM-IV criteria for major depression, dysthymia, or depression not otherwise specified were tested on dichotic fused-words and complex tones tests before completing 12 weeks of fluoxetine treatment. Perceptual asymmetry (PA) scores were compared for 75 patients (38 women) who responded to treatment and 39 patients (14 women) who were nonresponders. Normative data were also obtained for 101 healthy adults (61 women). Patients who responded to fluoxetine differed from nonresponders and healthy adults in favoring left- over right-hemisphere processing of dichotic stimuli, and this difference was dependent on gender and test. Heightened left-hemisphere advantage for dichotic words in responders was present among women but not men, whereas reduced right-hemisphere advantage for dichotic tones in responders was present among men but not women. Pretreatment PA was also predictive of change in depression severity following treatment. Responder vs nonresponder differences for verbal dichotic listening in women and nonverbal dichotic listening in men are discussed in terms of differences in cognitive function, hemispheric organization, and neurotransmitter function.

  7. Functional testing of space flight induced changes in tonic motor control by using limb-attached excitation and load devices

    NASA Astrophysics Data System (ADS)

    Gallasch, Eugen; Kozlovskaya, Inessa

    2007-02-01

    Long term space flights induce atrophy and contractile changes on postural muscles such effecting tonic motor control. Functional testing of tonic motor control structures is a challenge because of the difficulties to deliver appropriate test forces on crew members. In this paper we propose two approaches for functional testing by using limb attached loading devices. The first approach is based on a frequency and amplitude controllable moving magnet exciter to deliver sinusoidal test forces during limb postures. The responding limb deflection is recorded by an embedded accelerometer to obtain limb impedance. The second approach is based on elastic limb loading to evoke self-excited oscillations during arm extensions. Here the contraction force at the oscillation onset provides information about limb stiffness. The rationale for both testing approaches is based on Feldman's λ-model. An arm expander based on the second approach was probed in a 6-month MIR space flight. The results obtained from the load oscillations, confirmed that this device is well suited to capture space flight induced neuromuscular changes.

  8. Normative Study of the Functional Assessment of Verbal Reasoning and Executive Strategies (FAVRES) Test in the French-Canadian Population

    ERIC Educational Resources Information Center

    Marcotte, Karine; McSween, Marie-Pier; Pouliot, Monica; Martineau, Sarah; Pauze, Anne-Marie; Wiseman-Hakes, Catherine; MacDonald, Sheila

    2017-01-01

    Purpose: The Functional Assessment of Verbal Reasoning and Executive Strategies (FAVRES; MacDonald, 2005) test was designed for use by speech-language pathologists to assess verbal reasoning, complex comprehension, discourse, and executive skills during performance on a set of challenging and ecologically valid functional tasks. A recent French…

  9. Implications of the International Classification of Functioning, Disability and Health (ICF) for Test Development and Use

    ERIC Educational Resources Information Center

    Carlson, Janet F.; Benson, Nicholas; Oakland, Thomas

    2010-01-01

    Implications of the International Classification of Functioning, Disability and Health (ICF) on the development and use of tests in school settings are enumerated. We predict increased demand for behavioural assessments that consider a person's activities, participation and person-environment interactions, including measures that: (a) address…

  10. Effects of Alcohol on Tests of Executive Functioning in Men and Women: A Dose Response Examination

    PubMed Central

    Guillot, Casey R.; Fanning, Jennifer R.; Bullock, Joshua S.; McCloskey, Michael S.; Berman, Mitchell E.

    2014-01-01

    Alcohol has been shown to affect performance on tasks associated with executive functioning. However, studies in this area have generally been limited to a single dose or gender or have used small sample sizes. The purpose of this study was to provide a more nuanced and systematic examination of alcohol's effects on commonly used tests of executive functioning at multiple dosages in both men and women. Research volunteers (91 women and 94 men) were randomly assigned to one of four drink conditions (alcohol doses associated with target blood alcohol concentrations of .000%, .050%, .075% and .100%). Participants then completed three tasks comprising two domains of executive functioning: two set shifting tasks, the Trail Making Test and a computerized version of the Wisconsin Card Sorting Task, and a response inhibition task, the GoStop Impulsivity Paradigm. Impaired performance on set shifting tasks was found at the .100% and .075% dosages, but alcohol intoxication did not impair performance on the GoStop. No gender effects emerged. Thus, alcohol negatively affects set shifting at moderately high levels of intoxication in both men and women, likely due to alcohol's interference with prefrontal cortex function. Although it is well-established that alcohol negatively affects response inhibition as measured by auditory stop-signal tasks, alcohol does not appear to exert a negative effect on response inhibition as measured by the GoStop, a visual stop-signal task. PMID:20939644

  11. Testing family-centered, function-focused care in hospitalized persons with dementia.

    PubMed

    Boltz, Marie; Chippendale, Tracy; Resnick, Barbara; Galvin, James E

    2015-01-01

    Hospital-acquired disability causes decreased quality of life for patients with dementia and family caregivers, and increased societal costs. A comparative, repeated measures study tested the feasibility and preliminary efficacy of the family-centered, function-focused care intervention (Fam-FFC) in dyads of hospitalized, medical patients with dementia and family caregivers (FCGs). The intervention group demonstrated better activities of daily living and walking performance, and less severity/duration of delirium and hospital readmissions, but no significant differences in gait/balance. FCGs showed increased preparedness for caregiving and less anxiety but no significant differences in depression, strain and mutuality. Fam-FFC presents a possible pathway to meeting the Triple Aim of improved patient care, improved patient health and reduced costs for persons with dementia.

  12. Relationship between theory of mind and functional independence is mediated by executive function.

    PubMed

    Ahmed, Fayeza S; Miller, L Stephen

    2013-06-01

    Theory of mind (ToM) is the ability to comprehend another person's perspective. Although there is much literature of ToM in children, there is a limited and somewhat inconclusive amount of studies examining ToM in a geriatric population. This study examined ToM's relationship to functional independence. Two tests of ToM, tests of executive function, and a measure of functional ability were administered to cognitively intact older adults. Results showed that 1 test of ToM (Strange Stories test) significantly accounted for variance in functional ability, whereas the other did not (Faux Pas test). In addition, Strange Stories test performance was partially driven by a verbal abstraction-based executive function: proverb interpretation. A multiple mediation model was employed to examine whether executive functions explained the relationship between the Strange Stories test and functional ability. Results showed that both the combined and individual indirect effects of the executive function measures mediated the relationship. We argue that, although components of ToM are associated with functional independence, ToM does not appear to account for additional variance in functional independence beyond executive function measures. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  13. Does morphological convergence imply functional similarity? A test using the evolution of quadrupedalism in ornithischian dinosaurs.

    PubMed

    Maidment, Susannah C R; Barrett, Paul M

    2012-09-22

    Convergent morphologies are thought to indicate functional similarity, arising because of a limited number of evolutionary or developmental pathways. Extant taxa displaying convergent morphologies are used as analogues to assess function in extinct taxa with similar characteristics. However, functional studies of extant taxa have shown that functional similarity can arise from differing morphologies, calling into question the paradigm that form and function are closely related. We test the hypothesis that convergent skeletal morphology indicates functional similarity in the fossil record using ornithischian dinosaurs. The rare transition from bipedality to quadrupedality occurred at least three times independently in this clade, resulting in a suite of convergent osteological characteristics. We use homology rather than analogy to provide an independent line of evidence about function, reconstructing soft tissues using the extant phylogenetic bracket and applying biomechanical concepts to produce qualitative assessments of muscle leverage. We also optimize character changes to investigate the sequence of character acquisition. Different lineages of quadrupedal ornithischian dinosaur stood and walked differently from each other, falsifying the hypothesis that osteological convergence indicates functional similarity. The acquisition of features correlated with quadrupedalism generally occurs in the same order in each clade, suggesting underlying developmental mechanisms that act as evolutionary constraints.

  14. Reliability of breath by breath spirometry and relative flow-time indices for pulmonary function testing in horses.

    PubMed

    Burnheim, K; Hughes, K J; Evans, D L; Raidal, S L

    2016-11-28

    Respiratory problems are common in horses, and are often diagnosed as a cause of poor athletic performance. Reliable, accurate and sensitive spirometric tests of airway function in resting horses would assist with the diagnosis of limitations to breathing and facilitate investigations of the effects of various treatments on breathing capacity. The evaluation of respiratory function in horses is challenging and suitable procedures are not widely available to equine practitioners. The determination of relative flow or flow-time measures is used in paediatric patients where compliance may limit conventional pulmonary function techniques. The aim of the current study was to characterise absolute and relative indices of respiratory function in healthy horses during eupnoea (tidal breathing) and carbon dioxide (CO 2 )-induced hyperpnoea (rebreathing) using a modified mask pneumotrachographic technique well suited to equine practice, and to evaluate the reliability of this technique over three consecutive days. Coefficients of variation, intra-class correlations, mean differences and 95% confidence intervals across all days of testing were established for each parameter. The technique provided absolute measures of respiratory function (respiratory rate, tidal volume, peak inspiratory and expiratory flows, time to peak flow) consistent with previous studies and there was no significant effect of day on any measure of respiratory function. Variability of measurements was decreased during hyperpnea caused by rebreathing CO 2 , but a number of relative flow-time variables demonstrated good agreement during eupnoeic respiration. The technique was well tolerated by horses and study findings suggest the technique is suitable for evaluation of respiratory function in horses. The use of relative flow-time variables provided reproducible (consistent) results, suggesting the technique may be of use for repeated measures studies in horses during tidal breathing or rebreathing.

  15. Item response theory, computerized adaptive testing, and PROMIS: assessment of physical function.

    PubMed

    Fries, James F; Witter, James; Rose, Matthias; Cella, David; Khanna, Dinesh; Morgan-DeWitt, Esi

    2014-01-01

    Patient-reported outcome (PRO) questionnaires record health information directly from research participants because observers may not accurately represent the patient perspective. Patient-reported Outcomes Measurement Information System (PROMIS) is a US National Institutes of Health cooperative group charged with bringing PRO to a new level of precision and standardization across diseases by item development and use of item response theory (IRT). With IRT methods, improved items are calibrated on an underlying concept to form an item bank for a "domain" such as physical function (PF). The most informative items can be combined to construct efficient "instruments" such as 10-item or 20-item PF static forms. Each item is calibrated on the basis of the probability that a given person will respond at a given level, and the ability of the item to discriminate people from one another. Tailored forms may cover any desired level of the domain being measured. Computerized adaptive testing (CAT) selects the best items to sharpen the estimate of a person's functional ability, based on prior responses to earlier questions. PROMIS item banks have been improved with experience from several thousand items, and are calibrated on over 21,000 respondents. In areas tested to date, PROMIS PF instruments are superior or equal to Health Assessment Questionnaire and Medical Outcome Study Short Form-36 Survey legacy instruments in clarity, translatability, patient importance, reliability, and sensitivity to change. Precise measures, such as PROMIS, efficiently incorporate patient self-report of health into research, potentially reducing research cost by lowering sample size requirements. The advent of routine IRT applications has the potential to transform PRO measurement.

  16. OBSERVER RATING VERSUS THREE-DIMENSIONAL MOTION ANALYSIS OF LOWER EXTREMITY KINEMATICS DURING FUNCTIONAL SCREENING TESTS: A SYSTEMATIC REVIEW.

    PubMed

    Maclachlan, Liam; White, Steven G; Reid, Duncan

    2015-08-01

    Functional assessments are conducted in both clinical and athletic settings in an attempt to identify those individuals who exhibit movement patterns that may increase their risk of non-contact injury. In place of highly sophisticated three-dimensional motion analysis, functional testing can be completed through observation. To evaluate the validity of movement observation assessments by summarizing the results of articles comparing human observation in real-time or video play-back and three-dimensional motion analysis of lower extremity kinematics during functional screening tests. Systematic review. A computerized systematic search was conducted through Medline, SPORTSdiscus, Scopus, Cinhal, and Cochrane health databases between February and April of 2014. Validity studies comparing human observation (real-time or video play-back) to three-dimensional motion analysis of functional tasks were selected. Only studies comprising uninjured, healthy subjects conducting lower extremity functional assessments were appropriate for review. Eligible observers were certified health practitioners or qualified members of sports and athletic training teams that conduct athlete screening. The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to appraise the literature. Results are presented in terms of functional tasks. Six studies met the inclusion criteria. Across these studies, two-legged squats, single-leg squats, drop-jumps, and running and cutting manoeuvres were the functional tasks analysed. When compared to three-dimensional motion analysis, observer ratings of lower extremity kinematics, such as knee position in relation to the foot, demonstrated mixed results. Single-leg squats achieved target sensitivity values (≥ 80%) but not specificity values (≥ 50%>%). Drop-jump task agreement ranged from poor (< 50%) to excellent (> 80%). Two-legged squats achieved 88% sensitivity and 85% specificity. Mean underestimations as large as 198 (peak knee

  17. Pulmonary function test findings in patients with acute inhalation injury caused by smoke bombs

    PubMed Central

    Cao, Lu; Zhang, Xin-Gang; Wang, Jian-Guo; Wang, Han-Bin; Chen, Yi-Bing; Zhao, Da-Hui; Shi, Wen-Fang

    2016-01-01

    Background This study aimed to determine the effects of smoke bomb-induced acute inhalation injury on pulmonary function at different stages of lung injury. Methods We performed pulmonary function tests (PFTs) in 15 patients with acute inhalation injury from days 3 to 180 after smoke inhalation. We measured the trace element zinc in whole blood on days 4 and 17, and correlations of zinc levels with PFTs were performed. Results In the acute stage of lung injury (day 3), 3 of 11 patients with mild symptoms had normal pulmonary function and 8 patients with restrictive ventilatory dysfunction and reduced diffusing capacity. Some patients also had mild obstructive ventilatory dysfunction (5 patients) and a decline in small airway function (6 patients). For patients with severe symptoms, PFT results showed moderate to severe restrictive ventilatory dysfunction and reduced diffusing capacity. PaCO2 was significantly higher (P=0.047) in patients with reduced small airway function compared with those with normal small airway function. Whole blood zinc levels in the convalescence stage (day 17) were significantly lower than those in the acute stage (day 4). Zinc in the acute stage was negatively correlated with DLCO/VA on days 3, 10, and 46 (r=−0.633, −0.676, and −0.675 respectively, P<0.05). Conclusions Smoke inhalation injury mainly causes restrictive ventilatory dysfunction and reduced diffusing capacity, and causes mild obstructive ventilatory dysfunction and small airway function decline in some patients. Zinc is negatively correlated with DLCO/VA. Zinc levels may be able to predict prognosis and indicate the degree of lung injury. PMID:28066595

  18. Driving with Mild Cognitive Impairment or Dementia: Cognitive Test Performance and Proxy Report of Daily Life Function in Older Women.

    PubMed

    Vaughan, Leslie; Hogan, Patricia E; Rapp, Stephen R; Dugan, Elizabeth; Marottoli, Richard A; Snively, Beverly M; Shumaker, Sally A; Sink, Kaycee M

    2015-09-01

    To investigate associations between proxy report of cognitive and functional limitations and cognitive performance and current or former driving status in older women with mild cognitive impairment (MCI) and all-cause dementia. Cross-sectional data analysis of retrospectively identified older women with adjudicated MCI and all-cause dementia in the Women's Health Initiative Memory Study-Epidemiology of Cognitive Health Outcomes (WHIMS-ECHO). Academic medical center. Women (mean age ± standard deviation 83.7 ± 3.5) adjudicated with MCI or dementia during Year 1, 2, 3, or 4 of the WHIMS-ECHO follow-up period (N = 385). The telephone-administered cognitive battery included tests of attention, verbal learning and memory, verbal fluency, executive function, working memory, and global cognitive function plus self-report measures of depressive symptomatology. The Dementia Questionnaire (DQ) was administered to a knowledgeable proxy (family member, friend). Sixty percent of women with MCI and 40% of those with dementia are current drivers. Proxy reports of functional limitations in instrumental activities of daily living (IADLs) are associated with current driving status in women with MCI, whereas performance-based cognitive tests are not. In women with dementia, proxy reports of functional limitations in IADLs and performance-based cognitive tests are associated with current driving status, as expected. These findings have clinical implications for the importance of evaluating driving concurrently with other instrumental functional abilities in MCI and dementia. Additional work is needed to determine whether proxy report of cognitive and functional impairments should help guide referrals for driving assessment and rehabilitation or counseling for driving transition. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.

  19. Asymmetries in functional hop tests, lower extremity kinematics, and isokinetic strength persist 6 to 9 months following anterior cruciate ligament reconstruction.

    PubMed

    Xergia, Sofia A; Pappas, Evangelos; Zampeli, Franceska; Georgiou, Spyros; Georgoulis, Anastasios D

    2013-03-01

    Within-subject and between-subject cross-sectional study. To investigate symmetry in hop-test performance, strength, and lower extremity kinematics 6 to 9 months following anterior cruciate ligament reconstruction (ACLR). Despite the extensive body of literature involving persons following ACLR, no study has comprehensively evaluated measures of strength, lower extremity kinematics, and functional performance of functional hop tests in this population. The subjects were 22 men (mean ± SD age, 28.8 ± 11.2 years) who had ACLR using a bone-patellar tendon-bone autograft 6 to 9 (7.01 ± 0.93) months previously and 22 healthy male controls (age, 24.8 ± 9.1 years). Participants completed a self-report questionnaire and underwent isokinetic strength testing and functional and kinematic assessment of the single-, triple-, and crossover-hop tests. Two-way analyses of variance were used to test for differences between the ACLR group and the control group, and between the 2 lower extremities of the ACLR group. Compared to the control group, the ACLR group had greater isokinetic knee extension torque deficits at all speeds (P ≤.001) and greater performance asymmetry for all 3 hop tests (P<.001). Compared to the noninvolved lower extremity, the involved lower extremity of the ACLR group exhibited less ankle dorsiflexion and knee flexion in the phases of propulsion (P ≤.014) and landing (P ≤.032). When compared to the control group, the involved lower extremity exhibited less ankle dorsiflexion in the propulsion phase (P<.001) but higher hip flexion in the landing phase (P = .014). Six to 9 months following ACLR, patients continue to demonstrate functional hop and isokinetic knee extension deficits, as well as kinematic differences, during the propulsion and landing phases of the hop tests.

  20. Long-term and short-term effects of hemodialysis on liver function evaluated using the galactose single-point test.

    PubMed

    Hou, Yi-Chou; Liu, Wen-Chih; Liao, Min-Tser; Lu, Kuo-Cheng; Lo, Lan; Pan, Heng-Chih; Wu, Chia-Chao; Hu, Oliver Yoa-Pu; Tang, Hung-Shang

    2014-01-01

    The galactose single-point (GSP) test assesses functioning liver mass by measuring the galactose concentration in the blood 1 hour after its administration. The purpose of this study was to investigate the impact of hemodialysis (HD) on short-term and long-term liver function by use of GSP test. Seventy-four patients on maintenance HD (46 males and 28 females, 60.38 ± 11.86 years) with a mean time on HD of 60.77 ± 48.31 months were studied. The GSP values were compared in two groups: (1) before and after single session HD, and (2) after one year of maintenance HD. Among the 74 HD patient, only the post-HD Cr levels and years on dialysis were significantly correlated with GSP values (r = 0.280, P < 0.05 and r = -0.240, P < 0.05, resp.). 14 of 74 patients were selected for GSP evaluation before and after a single HD session, and the hepatic clearance of galactose was similar (pre-HD 410 ± 254 g/mL, post-HD 439 ± 298 g/mL, P = 0.49). GSP values decreased from 420.20 ± 175.26 g/mL to 383.40 ± 153.97 g/mL after 1 year maintenance HD in other 15 patients (mean difference: 19.00 ± 37.66 g/mL, P < 0.05). Patients on maintenance HD for several years may experience improvement of their liver function. However, a single HD session does not affect liver function significantly as assessed by the GSP test. Since the metabolism of galactose is dependent on liver blood flow and hepatic functional mass, further studies are needed.