Sample records for kenyan blood samples

  1. Detection and quantification of Plasmodium falciparum in blood samples using quantitative nucleic acid sequence-based amplification.

    PubMed

    Schoone, G J; Oskam, L; Kroon, N C; Schallig, H D; Omar, S A

    2000-11-01

    A quantitative nucleic acid sequence-based amplification (QT-NASBA) assay for the detection of Plasmodium parasites has been developed. Primers and probes were selected on the basis of the sequence of the small-subunit rRNA gene. Quantification was achieved by coamplification of the RNA in the sample with one modified in vitro RNA as a competitor in a single-tube NASBA reaction. Parasite densities ranging from 10 to 10(8) Plasmodium falciparum parasites per ml could be demonstrated and quantified in whole blood. This is approximately 1,000 times more sensitive than conventional microscopy analysis of thick blood smears. Comparison of the parasite densities obtained by microscopy and QT-NASBA with 120 blood samples from Kenyan patients with clinical malaria revealed that for 112 of 120 (93%) of the samples results were within a 1-log difference. QT-NASBA may be especially useful for the detection of low parasite levels in patients with early-stage malaria and for the monitoring of the efficacy of drug treatment.

  2. Angular photogrammetric comparison of the soft-tissue facial profile of Kenyans and Chinese.

    PubMed

    Wamalwa, Peter; Amisi, Stella Kabarika; Wang, Yunji; Chen, Song

    2011-05-01

    The purpose of this study was to determine the average angular dimensions that define the normal soft-tissue facial profiles of black Kenyans and Chinese and compare them with each other and with values proposed for whites. Standardized facial profile photographs, taken in natural head position, of 177 black Kenyans and 156 Chinese with normal occlusion and well-balanced faces were analyzed for 12 angular parameters. Two-sample t-tests were used to determine sex and racial differences. Kenyan and Chinese averages were compared with proposed white values using 1-sample t-tests. Eight parameters in Kenyans and 7 in Chinese showed sex differences. All angles, except for facial convexity, nasal dorsum, and inferior facial height, were different between Kenyans and Chinese. Kenyan and Chinese averages for all parameters were different from proposed white average, except for facial convexity. Nasolabial and mentolabial angles showed large individual variability and racial differences. The study demonstrated many differences in average angular measurements of the facial profiles of black Kenyans, Chinese, and white standards. Orthodontists, maxillofacial and plastic surgeons, and other clinicians working in the craniofacial region should bear these in mind when setting aesthetic treatment goals for patients of different races. Mean values from this study can be used for comparison with similar records of subjects with same ethnicity.

  3. Kenyan School and Culture.

    ERIC Educational Resources Information Center

    D'Souza, Henry

    1980-01-01

    The author defines African culture in a Kenyan context and proposes a tri-polar cultural paradigm to chart the metamorphosis of Kenyan culture from a traditional through a national to an international focus. He makes suggestions for the role of the school in promoting an international cultural standard. (Author/SJL)

  4. An Exploratory Factor Analysis of the Brief COPE with a Sample of Kenyan Caregivers

    ERIC Educational Resources Information Center

    Kimemia, Muthoni; Asner-Self, Kimberly K.; Daire, Andrew P.

    2011-01-01

    Given the high prevalence of HIV/AIDS in Kenya, more Kenyans now find themselves in the role of informal caregiver for a family member or multiple family members living with HIV/AIDS. However, there exists little research on how these individuals cope. The present study explores coping responses among caregivers for family members living with…

  5. Pedometer-determined physical activity of Western Kenyan children.

    PubMed

    Croteau, Karen; Schofield, Grant; Towle, George; Suresh, Vijiayarani

    2011-08-01

    It is speculated that rural Kenyan children are more physically active than those in developed countries. The purpose of this study was to examine pedometer-measured physical activity levels of western Kenyan youth. Participants in this study were children in Levels 3 and 5 who attended a private primary school. The sample (n = 72) consisted of 43 girls and 29 boys (average age = 9.8 ± 1.1, range = 8-12 years). Age, gender, tribe, and height and weight measures were collected. Weight status category was determined according to CDC guidelines. Participants wore a sealed Yamax pedometer for 4 weekdays during the measurement period. Data analysis included descriptive statistics and 2-way ANOVA (age × gender). The total sample averaged 14558 ± 3993 daily steps. There was no significant effect for age [F(4,68) = 1.682, P = .102] nor significant age × gender interaction [F(4,68)=1.956, P = .117]. There was a significant effect for gender [F(1,68) = 4.791, P = .033], with boys (16262 ± 4698) significantly more active than girls (13463 ± 3051). The observed daily steps are higher than those observed in the U.S., similar to samples in other developed countries, but lower than Amish youth.

  6. Fatherhood in Kenyan Ethnic Communities: Implication for Child Development

    ERIC Educational Resources Information Center

    Lasser, Jon; Fite, Kathleen; Wadende, Akinyi P.

    2011-01-01

    This article reviews the traditional and evolving constructions of fatherhood in Kenyan society, with an emphasis on fatherhood's impact on child development outcomes. Western influence and increased access to technology have changed the role of the Kenyan father, and in turn affected his role in the family. Special attention is given to…

  7. The attitudes of Kenyan in-school adolescents toward sexual autonomy.

    PubMed

    Adaji, Sunday E; Warenius, Linnea U; Ong'any, Antony A; Faxelid, Elisabeth A

    2010-03-01

    This was a cross-sectional study to examine the attitudes of Kenyan in-school adolescents towards premarital sex, unwanted pregnancies/abortions and contraception. Data collection was undertaken using a structured questionnaire. Kenyan in-school adolescents have conservative attitudes toward premarital sex, disagreeing that adolescent boy and girls should be left alone to satisfy their sexual needs. The girls had the view that boys have uncontrollable sexual appetites. With regards to unwanted pregnancies, the majority of the respondents disagreed with allowing abortions for pregnant school girls while they agreed that a pregnant school girl should be allowed to return to school. However, the majority of the girls held the view that a school boy who had impregnated a school girl should be expelled from school. The attitudes of the respondents to contraception were also largely conservative. The conservative attitudes of the respondents conflicts with the findings of high levels of unsafe sex and reproductive ill-health among Kenyan adolescents. There is need to help Kenyan in-school adolescents to develop more realistic attitudes toward sexuality in order to improve their reproductive health.

  8. Manual versus automated blood sampling: impact of repeated blood sampling on stress parameters and behavior in male NMRI mice

    PubMed Central

    Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546

  9. Immune Blood Sample Draw

    NASA Image and Video Library

    2012-04-26

    ISS030-E-257690 (26 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares for IMMUNE venous blood sample draws in the Columbus laboratory of the International Space Station. Following the blood draws, the samples were temporarily stowed in the Minus Eighty Laboratory Freezer for ISS 1 (MELFI-1) and later packed together with saliva samples on the Soyuz TMA-22 for return to Earth for analysis.

  10. Choice of the Medium of Instruction in Kenyan Preschools: Averting Xenocentrism

    ERIC Educational Resources Information Center

    Waithaka, Esther N.

    2017-01-01

    This qualitative study sought to prompt a critical and reflective discourse on the dismal use of mother tongue in Kenyan early childhood education (ECE) institutions in an attempt to detect existence of xenocentrism. Although the Kenyan ECE policy framework sanctions use of the language of the catchment area when teaching and communicating with…

  11. Patient identification in blood sampling.

    PubMed

    Davidson, Anne; Bolton-Maggs, Paula

    The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.

  12. Industrialization Stresses, Alcohol Abuse & Substance Dependence: Differential Gender Effects in a Kenyan Rural Farming Community

    ERIC Educational Resources Information Center

    Walt, Lisa C.; Kinoti, Elias; Jason, Leonard A.

    2013-01-01

    Developing countries' industrialization and urbanization attempts have been linked to psychological distress and alcohol abuse. We used Hobfoll's COR theory to examine the relationship between gender, perceived resource loss (an indicator of industrialization stress), and alcohol abuse and dependence in a sample of Kenyan rural village men and…

  13. Undernutrition among Kenyan children: contribution of child, maternal and household factors.

    PubMed

    Gewa, Constance A; Yandell, Nanette

    2012-06-01

    To examine the contribution of selected child-, maternal- and household-related factors to child undernutrition across two different age groups of Kenyan under-5s. Demographic and Health Survey data, multistage stratified cluster sampling methodology. Rural and urban areas of Kenya. A total of 1851 children between the ages of 0 and 24 months and 1942 children between the ages of 25 and 59 months in Kenya. Thirty per cent of the younger children were stunted, 13 % were underweight and 8 % were wasted. Forty per cent of the older children were stunted, 17 % were underweight and 4 % were wasted. Longer breast-feeding duration, small birth size, childhood diarrhoea and/or cough, poor maternal nutritional status and urban residence were associated with higher odds of at least one form of undernutrition, while female gender, large birth size, up-to-date immunization, higher maternal age at first birth, BMI and education level at the time of the survey and higher household wealth were each associated with lower odds of at least one form of undernutrition among Kenyan children. The more proximal child factors had the strongest impact on the younger group of children while the intermediate and more distal maternal and household factors had the strongest impact on child undernutrition among the older group of children. The present analysis identifies determinants of undernutrition among two age groups of Kenyan pre-school children and demonstrates that the contribution of child, maternal and household factors on children's nutritional status varies with children's age.

  14. Urbanisation and the nutrition transition: a comparison of diet and weight status of South African and Kenyan women.

    PubMed

    Steyn, Nelia P; Nel, Johanna H; Parker, W; Ayah, Rosemary; Mbithe, Dorcus

    2012-05-01

    To determine and compare the extent of the nutrition transition between Kenyan and South African women. A nationally representative sample of women aged ≥15 years (n=1008) was assessed in Kenya. Weight, height, and waist and hip circumferences were measured. A 24-hour dietary recall was conducted with each participant. This data was compared with data of the Demographic and Health Survey (DHS) of women in South Africa (n=4481). Dietary intake of South African women was based on secondary data analysis of dietary studies using the 24-hour recall method (n=1726). In South Africa, 27.4% women had a BMI ≥30 kg/m(2) compared with 14.2% of Kenyan women. In both countries there were large urban-rural differences in BMI, with the highest prevalence in women in urban areas. BMI increased with age, as did abdominal obesity which was equally prolific in both countries with more than 45% of women in the older groups having a waist/hip ratio ≥0.85. The nutrient mean adequacy ratio (MAR) of the South African rural diet was lower than those of the Kenyans diet (55.9; 57.3%, respectively). Dietary diversity score (DDS) and food variety score (FVS) were significantly lower in South African rural women (3.3; 4.9) compared with Kenyans (4.5; 6.8). Urban-rural differences in diet and weight status indicates that the nutrition transition was similar in both countries despite large sociodemographic differences; however, rural Kenyan women had a better MAR, DDS, and FVS than South African women, most probably due to 60% having access to land.

  15. Classroom Interaction in Kenyan Primary Schools.

    ERIC Educational Resources Information Center

    Ackers, Jim; Hardman, Frank

    2001-01-01

    Reports on a study of classroom interaction in Kenyan primary schools. Analyzes video recordings of 102 lessons in English, mathematics, and science using systematic observation, discourse analysis, and a time-line analysis. Reveals the preponderance of teacher dominated lessons with little opportunity for student interaction. Considers…

  16. Challenges of Implementing E-Learning in Kenya: A Case of Kenyan Public Universities

    ERIC Educational Resources Information Center

    Tarus, John K.; Gichoya, David; Muumbo, Alex

    2015-01-01

    In this paper, we discuss the challenges experienced by Kenyan public universities in implementation of e-learning and recommend possible solutions towards its successful implementation. In the last few years, most Kenyan public universities have adopted e-learning as a new approach to teaching and learning. However, the implementation challenges…

  17. Childhood overweight and obesity among Kenyan pre-school children: association with maternal and early child nutritional factors.

    PubMed

    Gewa, Constance A

    2010-04-01

    To report on the prevalence of overweight and obesity among pre-school children in Kenya and examine the associations between childhood overweight and selected maternal and child-related factors. Demographic Health Survey data, multistage stratified cluster sampling methodology. Rural and urban areas of Kenya. A total of 1495 children between the ages of 3 and 5 years in Kenya. Over 30 % of the children were stunted, approximately 16 % were underweight, 4 % were wasted, approximately 18 % were overweight and 4 % were obese; 8 % were both overweight/obese and stunted. Maternal overweight and obesity, higher levels of maternal education, being a large or very large child at birth, and being stunted were each associated with higher odds of overweight and obesity among Kenyan children. Older children and large household size were each associated with lower odds of overweight and obesity among Kenyan children. The analysis demonstrates the presence of under- and overnutrition among Kenyan pre-school children and the importance of focusing on expanding efforts to prevent and treat malnutrition within this population. It also identifies some of the modifiable factors that can be targeted in these efforts.

  18. Disaster Risk Management - The Kenyan Challenge

    NASA Astrophysics Data System (ADS)

    Nabutola, W.; Scheer, S.

    2009-04-01

    Keywords: natural disasters; man-made disasters; terrorist attacks; land slides; disaster policies and legislations; fire; earthquakes; hurricanes; soil erosion; disaster research policy; Preamble: "Risk does not begin and end on the floor of the New York Stock Exchange. The vastness of the subject matter is daunting. Risk touches on the most profound aspects of psychology, mathematics, statistics and history. The literature is monumental; each day's headlines bring many new items of interest. But I know we are not unique, everywhere in the world risks abound." "AGAINST THE GODS the remarkable story of risk" by Peter L. Bernstein, 1998 The real challenge is what can we, as a nation do to avert, prevent them, or in the unfortunate event that they occur, how can we mitigate their impact on the economy? Introductory remarks: Disaster in Kenya, as indeed anywhere else, is not one of those happenings we can wish away. It can strike anywhere any time. Some of it is man-made but most of it is natural. The natural are sometimes induced by man in one way or another. For example, when we harvest trees without replacing them, this diminishes the forest cover and can lead to soil erosion, whose advanced form is land slides. Either way disasters in their different forms and sizes present challenges to the way we live our lives or not, perhaps, even how we die. Disasters in our country have reached crisis stage. ‘In Chinese language, crisis means danger, but it also means opportunity' Les Brown, motivational speaker in "the power of a larger vision" Why I am interested Whereas Kenya experiences man made and natural disasters, there are more sinister challenges of the man-made variety. These loom on the horizon and, from time to time raise their ugly heads, taking many Kenyan lives in their wake, and property destroyed. These are post election violence and terrorist attacks, both related to politics, internal and external. In January 2008, soon after presidential and national

  19. Disaster Risk Management - The Kenyan Challenges

    NASA Astrophysics Data System (ADS)

    Nabutola, W.

    2009-04-01

    Keywords: natural disasters; man-made disasters; terrorist attacks; land slides; disaster policies and legislations; fire; earthquakes; hurricanes; soil erosion; disaster research policy; Preamble: "Risk does not begin and end on the floor of the New York Stock Exchange. The vastness of the subject matter is daunting. Risk touches on the most profound aspects of psychology, mathematics, statistics and history. The literature is monumental; each day's headlines bring many new items of interest. But I know we are not unique, everywhere in the world risks abound." "AGAINST THE GODS the remarkable story of risk" by Peter L. Bernstein, 1998 The real challenge is what can we, as a nation do to avert, prevent them, or in the unfortunate event that they occur, how can we mitigate their impact on the economy? Introductory remarks: Disaster in Kenya, as indeed anywhere else, is not one of those happenings we can wish away. It can strike anywhere any time. Some of it is man-made but most of it is natural. The natural are sometimes induced by man in one way or another. For example, when we harvest trees without replacing them, this diminishes the forest cover and can lead to soil erosion, whose advanced form is land slides. Either way disasters in their different forms and sizes present challenges to the way we live our lives or not, perhaps, even how we die. Disasters in our country have reached crisis stage. ‘In Chinese language, crisis means danger, but it also means opportunity' Les Brown, motivational speaker in "the power of a larger vision" Why I am interested Whereas Kenya experiences man made and natural disasters, there are more sinister challenges of the man-made variety. These loom on the horizon and, from time to time raise their ugly heads, taking many Kenyan lives in their wake, and property destroyed. These are post election violence and terrorist attacks, both related to politics, internal and external. In January 2008, soon after presidential and national

  20. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  1. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  2. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  3. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  4. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  5. Sampling and storage of blood for pH and blood gas analysis.

    PubMed

    Haskins, S C

    1977-02-15

    Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.

  6. [Blood sampling using "dried blood spot": a clinical biology revolution underway?].

    PubMed

    Hirtz, Christophe; Lehmann, Sylvain

    2015-01-01

    Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.

  7. Factors affecting blood sample haemolysis: a cross-sectional study.

    PubMed

    Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E

    2016-04-01

    To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.

  8. A Review of the Participation of Disabled Persons in the Labour Force: The Kenyan Context

    ERIC Educational Resources Information Center

    Opini, Bathseba M.

    2010-01-01

    This paper presents a review of the challenges that disabled people experience in participating in the Kenyan labour market. It draws on existing literature and on a narrative of the experiences of one disabled academic in a Kenyan university to highlight some of the forms of discrimination that disabled people have to cope with in their…

  9. Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.

    PubMed

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir

    2012-06-01

    According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT

  10. "From Worse to Better": How Kenyan Student-Teachers Can Use Participatory Action Research in Health Education

    ERIC Educational Resources Information Center

    Dahl, Kari Kragh Blume

    2014-01-01

    This study focuses on Kenyan student-teachers' professional learning and development in health education in a participatory action research project conducted in one Kenyan teacher training college. The aim was to explore the potential of participatory action research to instigate change in student-teachers' health education practices in a…

  11. School Counselor Preparation in Kenya: Do Kenyan School Counselors Feel Adequately Prepared to Perform Their Roles?

    ERIC Educational Resources Information Center

    Wambu, Grace W.; Wickman, Scott A.

    2016-01-01

    School counselor training in Kenya is a relatively new phenomenon. This study examined Kenyan school counselors' perceptions of the adequacy of their preparedness to perform their roles within the school setting. The survey was administered to 105 school counselors in four counties. The findings revealed that Kenyan school counselors perceived…

  12. Examining the Adjustment Problems of Kenyan International Students Attending Colleges and Universities in the United States

    ERIC Educational Resources Information Center

    Mokua, Rodgers Nyandieka

    2012-01-01

    The literature on international students from Africa, and particularly Kenya, is very limited despite the significant number of Kenyan international students attending colleges and universities in the United States. Therefore, the intent of this study was to examine the adjustment problems of Kenyan international students in the United States. The…

  13. Reference values for body composition and associations with blood pressure in Kenyan adults aged ≥50 years old.

    PubMed

    Bastawrous, Madeleine C; Piernas, Carmen; Bastawrous, Andrew; Oke, Jason; Lasserson, Daniel; Mathenge, Wanjiku; Burton, Matthew J; Jebb, Susan A; Kuper, Hannah

    2018-05-15

    To develop age- and sex-specific centile reference curves for fat-free mass (FFM) and fat mass (FM) adjusted for height in an adult Kenyan population and to investigate the association between FM, FFM and blood pressure (BP). Measures of body composition from bioimpedance analyses and BP were collected in 1995 participants aged ≥50 years in Nakuru County, Kenya. Reference curves were produced using the LMS method. Multivariable linear regression models were used to test the cross-sectional association between body composition indexes and BP. The age- and sex-specific reference curves for body composition (FMI and FFMI) confirmed that FFMI is lower in both men and women with increasing age. FMI declines with age in women while among men the decline starts after 70 years. FFM was higher in men (47.4 ± 7.2 kg) than in women (38.8 ± 5.5 kg), while FM was lower in men (17.3 ± 8.1 kg) than in women (24.4 ± 10.2 kg). FMI, FFMI and BMI were all positively associated with systolic and diastolic BP, and after adjusting for body weight, FFMI remained positively associated with systolic BP and the FMI remained positively associated with diastolic BP. There was no evidence to suggest that FMI and FFMI were superior to measurement of BMI alone. These body composition reference curves provide normative data on body composition for older adults in Kenya. Further research should consider the prospective associations with health, including frailty-related outcomes.

  14. Variant anatomy of renal arteries in a Kenyan population.

    PubMed

    Ogeng'o, Julius A; Masaki, Charles O; Sinkeet, Simeon R; Muthoka, Johnstone M; Murunga, Acleus K

    2010-01-01

    Variant anatomy of renal arteries is important in renal transplant, vascular reconstruction, and uroradiological procedures. The variations show ethnic and population differences. Data from Africans are scarce and altogether absent for Kenyans. To describe patterns of origin, trajectories and branching of renal arteries in a Kenyan population. Descriptive cross-sectional study conducted in the Department of Human Anatomy, University of Nairobi. Three hundred and fifty six kidneys from 178 cadavers and postmortem specimens were used in the study. Aorta, renal arteries and kidneys were exposed by dissection. Number, trajectories, level of branching, number of branches and point of entry into the kidney were recorded. Data was analyzed using SPSS version 16.0, and presented using macrographs, tables, and bar charts. Additional arteries occurred in 14.3% of the cases. In 82.4% of these, there was one additional artery. Fifty nine point five per cent of the double renal arteries were parallel and 7.1% crossed. Of the 305 single arteries, 76.4% showed hilar, 21.6% prehilar and 2% intraparenchymal branching. In the hilar branching, ladder type was present in 65% and fork type in 35%. Bifurcation and trifurcation were present in 59.6% and 33.1% respectively. Polar arteries were present in 16.9% cases. Over 14% of the Kenyan population may have additional renal arteries while more than 20% show early branching. Several trajectories and hilar branching patterns exist which renal transplant surgeons and radiologists should be aware of to avoid inadvertent vascular injury.

  15. Antibiotic Residues in Milk from Three Popular Kenyan Milk Vending Machines.

    PubMed

    Kosgey, Amos; Shitandi, Anakalo; Marion, Jason W

    2018-05-01

    Milk vending machines (MVMs) are growing in popularity in Kenya and worldwide. Milk vending machines dispense varying quantities of locally sourced, pasteurized milk. The Kenya Dairy Board has a regulatory framework, but surveillance is weak because of several factors. Milk vending machines' milk is not routinely screened for antibiotics, thereby increasing potential for antibiotic misuse. To investigate, a total of 80 milk samples from four commercial providers ( N = 25), street vendors ( N = 21), and three MVMs ( N = 34) were collected and screened in Eldoret, Kenya. Antibiotic residue surveillance occurred during December 2016 and January 2017 using Idexx SNAP ® tests for tetracyclines, sulfamethazine, beta-lactams, and gentamicin. Overall, 24% of MVM samples and 24% of street vendor samples were presumably positive for at least one antibiotic. No commercial samples were positive. Research into cost-effective screening methods and increased monitoring by food safety agencies are needed to uphold hazard analysis and critical control point for improving antibiotic stewardship throughout the Kenyan private dairy industry.

  16. Language Policy and Science Instruction in Kenyan Primary Schools.

    ERIC Educational Resources Information Center

    Cleghorn, Ailie; And Others

    1989-01-01

    Describes the difficulties encountered in Kenyan eighth grade science instruction when language policy restricts the use of local vernacular terms. Provides examples from three schools with differing policies on the use of English, Swahili, and tribal languages. Contains 21 references. (SV)

  17. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    NASA Technical Reports Server (NTRS)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  18. Non-terminal blood sampling techniques in guinea pigs.

    PubMed

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  19. Sailing against the Wind: Voices of Kenyan Adult Women in U.S. Postsecondary Education and Sociocultural Contexts

    ERIC Educational Resources Information Center

    Gatua, Mary Wairimu

    2014-01-01

    The purpose of this study was to explore the educational and sociocultural experiences of Kenyan women pursing higher education in the United States and how they negotiated their multiple identities. Using a sociocultural theoretical framework and narrative inquiry methodology, seven Kenyan immigrant women pursuing or who recently pursued advanced…

  20. Clinical Pharmacy Consultations Provided by American and Kenyan Pharmacy Students During an Acute Care Advanced Pharmacy Practice Experience

    PubMed Central

    Pastakia, Sonak D.; Manji, Imran; Kamau, Evelyn; Schellhase, Ellen M.

    2011-01-01

    Objective To compare the clinical consultations provided by American and Kenyan pharmacy students in an acute care setting in a developing country. Methods The documented pharmacy consultation recommendations made by American and Kenyan pharmacy students during patient care rounds on an advanced pharmacy practice experience at a referral hospital in Kenya were reviewed and classified according to type of intervention and therapeutic area. Results The Kenyan students documented more interventions than American students (16.7 vs. 12.0 interventions/day) and provided significantly more consultations regarding human immunodeficiency virus (HIV) and antibiotics. The top area of consultations provided by American students was cardiovascular diseases. Conclusions American and Kenyan pharmacy students successfully providing clinical pharmacy consultations in a resource-constrained, acute-care practice setting suggests an important role for pharmacy students in the reconciliation of prescriber orders with medication administration records and in providing drug information. PMID:21655396

  1. Research results: preserving newborn blood samples.

    PubMed

    Lewis, Michelle Huckaby; Scheurer, Michael E; Green, Robert C; McGuire, Amy L

    2012-11-07

    Retention and use, without explicit parental permission, of residual dried blood samples from newborn screening has generated public controversy over concerns about violations of family privacy rights and loss of parental autonomy. The public debate about this issue has included little discussion about the destruction of a potentially valuable public resource that can be used for research that may yield improvements in public health. The research community must advocate for policies and infrastructure that promote retention of residual dried blood samples and their use in biomedical research.

  2. Hemolysis associated with pneumatic tube system transport for blood samples

    PubMed Central

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830

  3. The Discourse of Classroom Interaction in Kenyan Primary Schools

    ERIC Educational Resources Information Center

    Pontefract, Caroline; Hardman, Frank

    2005-01-01

    This paper addresses the role of classroom discourse in supporting children's learning in Kenyan primary schools. The discourse strategies of 27 teachers teaching English, mathematics and science across the primary phase were intensively studied using discourse analysis and semi-structured interviews. A survey questionnaire (n = 359) was also used…

  4. Comment on Dissociation between running economy and running performance in elite Kenyan distance runners.

    PubMed

    Santos-Concejero, Jordan; Tucker, Ross

    2016-01-01

    Mooses and colleagues suggest that running economy alone does not explain superior distance running performance in elite Kenyan runners. Whilst we agree with the multi-factorial hypothesis for Kenyan running success, we do not believe that running economy can be overlooked to the extent that it was based on this particular study. Based on the methods used and the range of athletes tested, in this response letter we question whether this study provides any basis for downplaying the influence of running economy or suggesting that other factors compensate for it to enable superior performance.

  5. Dissociation between running economy and running performance in elite Kenyan distance runners.

    PubMed

    Mooses, Martin; Mooses, Kerli; Haile, Diresibachew Wondimu; Durussel, Jérôme; Kaasik, Priit; Pitsiladis, Yannis Paul

    2015-01-01

    The purpose of this study was to investigate the relationship between running economy (RE) and performance in a homogenous group of competitive Kenyan distance runners. Maximal aerobic capacity (VO2max) (68.8 ± 3.8 ml∙kg(-1)∙min(-1)) was determined on a motorised treadmill in 32 Kenyan (25.3 ± 5.0 years; IAAF performance score: 993 ± 77 p) distance runners. Leg anthropometry was assessed and moment arm of the Achilles tendon determined. While Achilles moment arm was associated with better RE (r(2) = 0.30, P = 0.003) and upper leg length, total leg length and total leg length to body height ratio were correlated with running performance (r = 0.42, P = 0.025; r = 0.40, P = 0.030 and r = 0.38, P = 0.043, respectively), RE and maximal time on treadmill (t(max)) were not associated with running performance (r = -0.01, P = 0.965; r = 0.27; P = 0.189, respectively) in competitive Kenyan distance runners. The dissociation between RE and running performance in this homogenous group of runners would suggest that RE can be compensated by other factors to maintain high performance levels and is in line with the idea that RE is only one of many factors explaining elite running performance.

  6. Stability of carboxyhemoglobin in stored and mailed blood samples.

    PubMed

    Hampson, Neil B

    2008-02-01

    Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.

  7. Effects of sample handling methods on substance P concentrations and immunoreactivity in bovine blood samples.

    PubMed

    Mosher, Ruby A; Coetzee, Johann F; Allen, Portia S; Havel, James A; Griffith, Gary R; Wang, Chong

    2014-02-01

    To determine the effects of protease inhibitors and holding times and temperatures before processing on the stability of substance P in bovine blood samples. Blood samples obtained from a healthy 6-month-old calf. Blood samples were dispensed into tubes containing exogenous substance P and 1 of 6 degradative enzyme inhibitor treatments: heparin, EDTA, EDTA with 1 of 2 concentrations of aprotinin, or EDTA with 1 of 2 concentrations of a commercially available protease inhibitor cocktail. Plasma was harvested immediately following collection or after 1, 3, 6, 12, or 24 hours of holding at ambient (20.3° to 25.4°C) or ice bath temperatures. Total substance P immunoreactivity was determined with an ELISA; concentrations of the substance P parent molecule, a metabolite composed of the 9 terminal amino acids, and a metabolite composed of the 5 terminal amino acids were determined with liquid chromatography-tandem mass spectrometry. Regarding blood samples processed immediately, no significant differences in substance P concentrations or immunoreactivity were detected among enzyme inhibitor treatments. In blood samples processed at 1 hour of holding, substance P parent molecule concentration was significantly lower for ambient temperature versus ice bath temperature holding conditions; aprotinin was the most effective inhibitor of substance P degradation at the ice bath temperature. The ELISA substance P immunoreactivity was typically lower for blood samples with heparin versus samples with other inhibitors processed at 1 hour of holding in either temperature condition. Results suggested that blood samples should be chilled and plasma harvested within 1 hour after collection to prevent substance P degradation.

  8. The Relationship between Kenyan Sign Language and English Literacy

    ERIC Educational Resources Information Center

    Aura, Lillie Josephine; Venville, Grady; Marais, Ida

    2016-01-01

    This paper presents results of an investigation into the relationship between Kenyan Sign Language (KSL) and English literacy skills. It is derived from research undertaken towards an MEd degree awarded by The University of Western Australia in 2011. The study employed a correlational survey strategy. Sixty upper primary deaf students from four…

  9. Challenges of Administering Teacher Education Programme in Kenyan Universities

    ERIC Educational Resources Information Center

    Genvieve, Nasimiyu

    2017-01-01

    Proper management of logistical issues in Teacher education programme tends to promote the quality of preparation of school teachers. The main objective of the study was to investigate challenges of administering teacher education programmes in Kenyan universities. The theoretical framework of the study was adopted as used by Koehler and Mishra's…

  10. Shifts in malaria vector species composition and transmission dynamics along the Kenyan coast over the past 20 years.

    PubMed

    Mwangangi, Joseph M; Mbogo, Charles M; Orindi, Benedict O; Muturi, Ephantus J; Midega, Janet T; Nzovu, Joseph; Gatakaa, Hellen; Githure, John; Borgemeister, Christian; Keating, Joseph; Beier, John C

    2013-01-08

    Over the past 20 years, numerous studies have investigated the ecology and behaviour of malaria vectors and Plasmodium falciparum malaria transmission on the coast of Kenya. Substantial progress has been made to control vector populations and reduce high malaria prevalence and severe disease. The goal of this paper was to examine trends over the past 20 years in Anopheles species composition, density, blood-feeding behaviour, and P. falciparum sporozoite transmission along the coast of Kenya. Using data collected from 1990 to 2010, vector density, species composition, blood-feeding patterns, and malaria transmission intensity was examined along the Kenyan coast. Mosquitoes were identified to species, based on morphological characteristics and DNA extracted from Anopheles gambiae for amplification. Using negative binomial generalized estimating equations, mosquito abundance over the period were modelled while adjusting for season. A multiple logistic regression model was used to analyse the sporozoite rates. Results show that in some areas along the Kenyan coast, Anopheles arabiensis and Anopheles merus have replaced An. gambiae sensu stricto (s.s.) and Anopheles funestus as the major mosquito species. Further, there has been a shift from human to animal feeding for both An. gambiae sensu lato (s.l.) (99% to 16%) and An. funestus (100% to 3%), and P. falciparum sporozoite rates have significantly declined over the last 20 years, with the lowest sporozoite rates being observed in 2007 (0.19%) and 2008 (0.34%). There has been, on average, a significant reduction in the abundance of An. gambiae s.l. over the years (IRR = 0.94, 95% CI 0.90-0.98), with the density standing at low levels of an average 0.006 mosquitoes/house in the year 2010. Reductions in the densities of the major malaria vectors and a shift from human to animal feeding have contributed to the decreased burden of malaria along the Kenyan coast. Vector species composition remains heterogeneous but in

  11. Kenyan Nurses Involvement in National Policy Development Processes

    PubMed Central

    Juma, Pamela Atieno

    2014-01-01

    The aim of this study was to critically examine how nurses have been involved in national policy processes in the Kenyan health sector. The paper reports qualitative results from a larger mixed method study. National nonnursing decision-makers and nurse leaders, and provincial managers as well as frontline nurse managers from two Kenyan districts were purposefully selected for interviews. Interviews dealt with nurses' involvement in national policy processes, factors hindering nurses' engagement in policy processes, and ways to enhance nurses' involvement in policy processes. Critical theory and feminist perspectives guided the study process. Content analysis of data was conducted. Findings revealed that nurses' involvement in policy processes in Kenya was limited. Only a few nurse leaders were involved in national policy committees as a result of their positions in the sector. Critical analysis of the findings revealed that hierarchies and structural factors as well as nursing professional issues were the primary barriers constraining nurses' involvement in policy processes. Thus, there is need to address these factors both by nurses themselves and by nonnursing decision makers, in order to enhance nurses engagement in policy making and further the contribution to quality of services to the communities. PMID:25349731

  12. Preparation of Teacher-Trainees in Pedagogy in Kenyan Universities

    ERIC Educational Resources Information Center

    Genvieve, Nasimiyu

    2017-01-01

    There has been a concern about the quality of school teachers being prepared at the university especially in pedagogy. The main objective of the study was to investigate the preparation of teacher-trainees in pedagogy in Kenyan universities.The theoretical framework of the study was based on Shulman's concept of pedagogical content knowledge. The…

  13. Emotional and Behavioral Problems among Impoverished Kenyan Youth: Factor Structure and Sex-Differences

    PubMed Central

    Harder, Valerie S.; Mutiso, Victoria N.; Khasakhala, Lincoln I.; Burke, Heather M.; Rettew, David C.; Ivanova, Masha Y.; Ndetei, David M.

    2014-01-01

    Data on youth emotional and behavioral problems from societies in Sub-Saharan Africa are lacking. This may be due to the fact that few youth mental health assessments have been tested for construct validity of syndrome structure across multicultural societies that include developing countries, and almost none have been tested in Sub-Saharan Africa. The Youth Self-Report (YSR), for example, has shown great consistency of its syndrome structure across many cultures, yet data from only one developing country in Sub-Saharan Africa have been included. In this study, we test the factor structure of YSR syndromes among Kenyan youth ages 11–18 years from an informal settlement in Nairobi, Kenya and examine sex-differences in levels of emotional and behavioral problems. We find the eight syndrome structure of the YSR to fit these data well (Root Mean Square Error of Approximation=.049). While Kenyan girls have significantly higher internalizing (Anxious/Depressed, Withdrawn/Depressed, Somatic) problem scores than boys, these differences are of similar magnitude to published multicultural findings. The results support the generalizability of the YSR syndrome structure to Kenyan youth and are in line with multicultural findings supporting the YSR as an assessment of emotional and behavioral problems in diverse societies. PMID:25419046

  14. Automated blood-sample handling in the clinical laboratory.

    PubMed

    Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O

    1990-09-01

    The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.

  15. Adverse Childhood Experiences Predict Alcohol Consumption Patterns Among Kenyan Mothers.

    PubMed

    Goodman, Michael L; Grouls, Astrid; Chen, Catherine X; Keiser, Philip H; Gitari, Stanley

    2017-04-16

    We analyze whether adverse childhood experiences predict weekly alcohol consumption patterns of Kenyan mothers and their partners. Randomly selected respondents (n = 1,976) were asked about adverse childhood experiences and alcohol consumption patterns for themselves and their partners. Fixed effect models were used to determine odds of reporting weekly alcohol consumption and the number of beverages typically consumed, controlling for wealth, age, education, and partner alcohol consumption. Cumulative adverse childhood experiences predicted higher odds of weekly alcohol consumption of the respondent and her partner. Childhood exposure to physical abuse, emotional neglect, and mental illness in the household significantly increased odds of weekly alcohol consumption by the respondent. More drinks consumed per typical session were higher among respondents with more cumulative adversities. Physical and emotional abuse significantly predicted number of drinks typically consumed by the respondent. To our knowledge, this is the first study to explore and find associations between adverse childhood experiences and alcohol consumption in Kenya. Consistent with high-income settings, exposure to childhood adversities predicted greater alcohol consumption among Kenyan women.

  16. Malaria PCR Detection in Cambodian Low-Transmission Settings: Dried Blood Spots versus Venous Blood Samples

    PubMed Central

    Canier, Lydie; Khim, Nimol; Kim, Saorin; Eam, Rotha; Khean, Chanra; Loch, Kaknika; Ken, Malen; Pannus, Pieter; Bosman, Philippe; Stassijns, Jorgen; Nackers, Fabienne; Alipon, SweetC; Char, Meng Chuor; Chea, Nguon; Etienne, William; De Smet, Martin; Kindermans, Jean-Marie; Ménard, Didier

    2015-01-01

    In the context of malaria elimination, novel strategies for detecting very low malaria parasite densities in asymptomatic individuals are needed. One of the major limitations of the malaria parasite detection methods is the volume of blood samples being analyzed. The objective of the study was to compare the diagnostic accuracy of a malaria polymerase chain reaction assay, from dried blood spots (DBS, 5 μL) and different volumes of venous blood (50 μL, 200 μL, and 1 mL). The limit of detection of the polymerase chain reaction assay, using calibrated Plasmodium falciparum blood dilutions, showed that venous blood samples (50 μL, 200 μL, 1 mL) combined with Qiagen extraction methods gave a similar threshold of 100 parasites/mL, ∼100-fold lower than 5 μL DBS/Instagene method. On a set of 521 field samples, collected in two different transmission areas in northern Cambodia, no significant difference in the proportion of parasite carriers, regardless of the methods used was found. The 5 μL DBS method missed 27% of the samples detected by the 1 mL venous blood method, but most of the missed parasites carriers were infected by Plasmodium vivax (84%). The remaining missed P. falciparum parasite carriers (N = 3) were only detected in high-transmission areas. PMID:25561570

  17. Career Experiences of Women Academicians in Kenyan Institutions of Higher Learning

    ERIC Educational Resources Information Center

    Nanyama, Evalyne

    2012-01-01

    Currently, women academicians in Kenya are underrepresented at all levels in Kenyan IHL, leading to less participation and integration into the administration and governance of higher institutions. As a result women academicians have little chance of making meaningful contributions to important policies and decisions that affect the institutions…

  18. Kinetic Modeling of PET Data Without Blood Sampling

    NASA Astrophysics Data System (ADS)

    Bentourkia, M.

    2005-06-01

    In positron emission tomography (PET) imaging, application of kinetic modeling always requires an input curve (IC) together with the PET data. The IC can be obtained by means of external blood sampling or, in the case of cardiac studies, by means of a region-of-interest (ROI) drawn on the blood pool. It is, however, very unsuitable to withdraw and to analyze blood samples, and in small animals, these operations become difficult, while ICs determined from ROIs are generally contaminated by emissions from neighboring sites, or they are underestimated because of partial volume effect. In this paper, we report a new method to extract kinetic parameters from dynamic PET studies without a priori knowledge of the IC. The method is applied in human brain data measured with fluorodeoxyglucose (FDG) human-brain and in cardiac-rat perfusion studies with /sup 13/N-ammonia and /sup 11/C-acetate. The tissue blood volume (TBV), usually fitted together with the rate constants, is extracted simultaneously with the tissue time activity curves for cardiac studies, while for brain gray matter, TBV is known to be about 4% to 7%. The shape of IC is obtained by means of factor analysis from an ROI drawn around a cardiac tissue or a brain artery. The results show a good correlation (p<0.05) between the cerebral metabolic rate of glucose, myocardial blood flow, and oxygen consumption obtained with the new method in comparison to the usual method. In conclusion, it is possible to apply kinetic modeling without any blood sampling, which significantly simplifies PET acquisition and data analysis.

  19. Spatial distribution and habitat characterisation of Anopheles larvae along the Kenyan coast

    PubMed Central

    Mwangangi, Joseph M.; Mbogo, Charles M.; Muturi, Ephantus J.; Nzovu, Joseph G.; Githure, John I.; Yan, Guiyun; Minakawa, Noboru; Novak, Robert; Beier, John C.

    2009-01-01

    Background & objectives A study was conducted to characterise larval habitats and to determine spatial heterogeneity of the Anopheles mosquito larvae. The study was conducted from May to June 1999 in nine villages along the Kenyan coast. Methods Aquatic habitats were sampled by use of standard dipping technique. The habitats were characterised based on size, pH, distance to the nearest house, coverage of canopy, surface debris, algae and emergent plants, turbidity, substrate, and habitat type. Results A total of 110 aquatic habitats like stream pools (n = 10); puddles (n = 65); tire tracks (n = 5); ponds (n = 5) and swamps (n = 25) were sampled in nine villages located in three districts of the Kenyan coast. A total of 7,263 Anopheles mosquito larvae were collected, 63.9% were early instars and 36.1% were late instars. Morphological identification of the III and IV instar larvae by use of microscopy yielded 90.66% (n = 2,377) Anopheles gambiae Complex, 0.88% (n = 23) An. funestus, An. coustani 7.63% (n = 200), An. rivulorum 0.42% (n = 11), An. pharoensis 0.19% (n = 5), An. swahilicus 0.08% (n = 2), An. wilsoni 0.04% (n = 1) and 0.11% (n = 3) were unidentified. A subset of the An. gambiae Complex larvae identified morphologically, was further analysed using rDNA-PCR technique resulting in 68.22% (n = 1,290) An. gambiae s.s., 7.93% (n = 150) An. arabiensis and 23.85% (n = 451) An. merus. Multiple logistic regression model showed that emergent plants (p = 0.019), and floating debris (p = 0.038) were the best predictors of An. gambiae larval abundance in these habitats. Interpretation & conclusion Habitat type, floating debris and emergent plants were found to be the key factors determining the presence of Anopheles larvae in the habitats. For effective larval control, the type of habitat should be considered and most productive habitat type be given a priority in the mosquito abatement programme. PMID:17378216

  20. Spatial distribution and habitat characterisation of Anopheles larvae along the Kenyan coast.

    PubMed

    Mwangangi, Joseph M; Mbogo, Charles M; Muturi, Ephantus J; Nzovu, Joseph G; Githure, John I; Yan, Guiyun; Minakawa, Noboru; Novak, Robert; Beier, John C

    2007-03-01

    A study was conducted to characterise larval habitats and to determine spatial heterogeneity of the Anopheles mosquito larvae. The study was conducted from May to June 1999 in nine villages along the Kenyan coast. Aquatic habitats were sampled by use of standard dipping technique. The habitats were characterised based on size, pH, distance to the nearest house, coverage of canopy, surface debris, algae and emergent plants, turbidity, substrate, and habitat type. A total of 110 aquatic habitats like stream pools (n=10); puddles (n=65); tire tracks (n=5); ponds (n=5) and swamps (n=25) were sampled in nine villages located in three districts of the Kenyan coast. A total of 7,263 Anopheles mosquito larvae were collected, 63.9% were early instars and 36.1% were late instars. Morphological identification of the III and IV instar larvae by use of microscopy yielded 90.66% (n=2377) Anopheles gambiae Complex, 0.88% (n=23) An. funestus, An. coustani 7.63% (n=200), An. rivulorum 0.42% (n=11), An. pharoensis 0.19% (n=5), An. swahilicus 0.08% (n=2), An. wilsoni 0.04% (n=1) and 0.11% (n=3) were unidentified. A subset of the An. gambiae Complex larvae identified morphologically, was further analysed using rDNA-PCR technique resulting in 68.22% (n=1290) An. gambiae s.s., 7.93% (n=150) An. arabiensis and 23.85% (n=451) An. merus. Multiple logistic regression model showed that emergent plants (p = 0.019), and floating debris (p = 0.038) were the best predictors of An. gambiae larval abundance in these habitats. Habitat type, floating debris and emergent plants were found to be the key factors determining the presence of Anopheles larvae in the habitats. For effective larval control, the type of habitat should be considered and most productive habitat type be given a priority in the mosquito abatement programme.

  1. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    PubMed

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. "Paradoxical Health Education": Learning about Health in Kenyan Teacher Training Colleges

    ERIC Educational Resources Information Center

    Dahl, Kari Kragh Blume

    2014-01-01

    This paper suggests the term "paradoxical" to understand how health education (HE) is carried out and experienced as contradictory and inconsistent by student-teachers who learn about health in Kenyan teacher training colleges (TTC). The claim is that students, apart from formal HE lessons, also learn about health in non-curricular HE,…

  3. Testing and testing positive: childhood adversities and later life HIV status among Kenyan women and their partners.

    PubMed

    Goodman, Michael L; Raimer-Goodman, Lauren; Chen, Catherine X; Grouls, Astrid; Gitari, Stanley; Keiser, Philip H

    2017-12-01

    Adverse childhood experiences are a critical feature of lifelong health. No research assesses whether childhood adversities predict HIV-testing behaviors, and little research analyzes childhood adversities and later life HIV status in sub-Saharan Africa. We use regression models with cross-sectional data from a representative sample (n = 1974) to analyze whether adverse childhood experiences, separately or as cumulative exposures, predict reports of later life HIV testing and testing HIV+ among semi-rural Kenyan women and their partners. No significant correlation was observed between thirteen cumulative childhood adversities and reporting prior HIV testing for respondent or partner. Separately, childhood sexual abuse and emotional neglect predicted lower odds of reporting having previously been tested for HIV. Witnessing household violence during one's childhood predicted significantly higher odds of reporting HIV+. Sexual abuse predicted higher odds of reporting a partner tested HIV+. Preventing sexual abuse and household violence may improve HIV testing and test outcomes among Kenyan women. More research is required to understand pathways between adverse childhood experiences and partner selection within Kenya and sub-Saharan Africa, and data presented here suggest understanding pathways may help improve HIV outcomes. © The Author 2016. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    NASA Astrophysics Data System (ADS)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  5. Teachers' Changing Roles in Computer Assisted Roles in Kenyan Secondary Schools

    ERIC Educational Resources Information Center

    Tanui, Edward K.; Kiboss, Joel K.; Walaba, Aggrey A.; Nassiuma, Dankit

    2008-01-01

    The use of computer technology in Kenyan schools is a relatively new approach that is currently being included in the school curriculum. The introduction of computer technology for use in teaching does not always seem to be accepted outright by most teachers. The purpose of the study reported in this paper was to investigate the teachers' changing…

  6. Integrated Literacies in a Rural Kenyan Girls' Secondary School Journalism Club

    ERIC Educational Resources Information Center

    Kendrick, Maureen; Early, Margaret; Chemjor, Walter

    2013-01-01

    Our purpose in this paper is to foreground contextual issues in studies of situated writing practices. During a year-long case study in a rural Kenyan secondary school, we applied a number of ethnographic techniques to document how 32 girls (aged 14-18 years) used local cultural and digital resources (i.e., donated digital cameras, voice…

  7. Microfluidic, marker-free isolation of circulating tumor cells from blood samples

    PubMed Central

    Karabacak, Nezihi Murat; Spuhler, Philipp S; Fachin, Fabio; Lim, Eugene J; Pai, Vincent; Ozkumur, Emre; Martel, Joseph M; Kojic, Nikola; Smith, Kyle; Chen, Pin-i; Yang, Jennifer; Hwang, Henry; Morgan, Bailey; Trautwein, Julie; Barber, Thomas A; Stott, Shannon L; Maheswaran, Shyamala; Kapur, Ravi; Haber, Daniel A; Toner, Mehmet

    2014-01-01

    The ability to isolate and analyze rare circulating tumor cells (CTCs) has the potential to further our understanding of cancer metastasis and enhance the care of cancer patients. In this protocol, we describe the procedure for isolating rare CTCs from blood samples by using tumor antigen–independent microfluidic CTC-iChip technology. The CTC-iChip uses deterministic lateral displacement, inertial focusing and magnetophoresis to sort up to 107 cells/s. By using two-stage magnetophoresis and depletion antibodies against leukocytes, we achieve 3.8-log depletion of white blood cells and a 97% yield of rare cells with a sample processing rate of 8 ml of whole blood/h. The CTC-iChip is compatible with standard cytopathological and RNA-based characterization methods. This protocol describes device production, assembly, blood sample preparation, system setup and the CTC isolation process. Sorting 8 ml of blood sample requires 2 h including setup time, and chip production requires 2–5 d. PMID:24577360

  8. Extensive monitoring through multiple blood samples in professional soccer players.

    PubMed

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter; Storskov, Anders; Kjær, Michael; Andersen, Jesper L

    2013-05-01

    The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players and to analyze different blood parameters in relation to seasonal changes in training and match exposure. Blood samples were collected 5 times during a 6-month period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, the players were tested for body composition, V[Combining Dot Above]O2max and physical performance by the Yo-Yo intermittent endurance submax test (IE2). Multiple variations in blood parameters occurred during the observation period, including a decrease in hemoglobin and an increase in hematocrit as the competitive season progressed. Iron and transferrin were stable, whereas ferritin showed a decrease at the end of the season. The immunoglobulin A (IgA) and IgM increased in the period with basal physical training and at the end of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. The V[Combining Dot Above]O2max decreased toward the end of the season, whereas no significant changes were observed in the IE2 test. The regular blood samples from elite soccer players reveal significant changes that may be related to changes in training pattern, match exposure, or length of the match season. Especially the end of the preparation season and at the end of the competitive season seem to be time points were the blood-derived values indicate that the players are under excessive physical strain and might be more subjected to a possible overreaching-overtraining conditions. We suggest that regular analyses of blood samples could be an important initiative to optimize training adaptation, training load, and game participation, but sampling has to be regular, and a database has to be built for each individual player.

  9. Preanalytic Factors Associated With Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Schold, Jesse D; Hustey, Frederic M; Chamberlin, Janelle; Procop, Gary W

    2018-02-01

    - Hemolysis of emergency department blood samples is a common occurrence and has a negative impact on health care delivery. - To determine the effect of preanalytic factors (straight stick, intravenous [IV] line, needle gauge, location of blood draw, syringe versus vacuum tube use, tourniquet time) on hemolysis in emergency department blood samples. - A single 65 000-visit emergency department's electronic health record was queried for emergency department potassium results and blood draw technique for all samples obtained in calendar year 2014, resulting in 54 531 potassium results. Hemolyzed potassium was measured by hemolysis index. Comparisons of hemolysis by sampling technique were conducted by χ 2 tests. - Overall hemolysis was 10.0% (5439 of 54 531). Hemolysis among samples obtained from straight stick was significantly less than among those obtained with IV line (5.4% [33 of 615] versus 10.2% [4821 of 47 266], P < .001). For IV-placed blood draws, antecubital location had a statistically significant lower overall hemolysis compared with other locations: 7.4% (2117 of 28 786) versus 14.6% (2622 of 17 960) ( P < .001). For blood drawn with a syringe compared with vacuum, hemolysis was 13.0% (92 of 705) and 11.0% (1820 of 16 590), respectively ( P = .09, not significant). For large-gauge IV blood draws versus smaller-gauge IV lines, a lower hemolysis was also observed (9.3% [3882 of 41 571] versus 16.7% [939 of 5633]) ( P < .001). For IV-drawn blood with tourniquet time less than 60 seconds, hemolysis was 10.3% (1362 of 13 162) versus 13.9% for more than 60 seconds (532 of 3832), P < .001. - This study confirmed previous findings that straight stick and antecubital location are significantly associated with reduced hemolysis and indicated that shorter tourniquet time and larger gauge for IV draws were significantly associated with lower hemolysis.

  10. Shorter Ground Contact Time and Better Running Economy: Evidence From Female Kenyan Runners.

    PubMed

    Mooses, Martin; Haile, Diresibachew W; Ojiambo, Robert; Sang, Meshack; Mooses, Kerli; Lane, Amy R; Hackney, Anthony C

    2018-06-25

    Mooses, M, Haile, DW, Ojiambo, R, Sang, M, Mooses, K, Lane, AR, and Hackney, AC. Shorter ground contact time and better running economy: evidence from female Kenyan runners. J Strength Cond Res XX(X): 000-000, 2018-Previously, it has been concluded that the improvement in running economy (RE) might be considered as a key to the continued improvement in performance when no further increase in V[Combining Dot Above]O2max is observed. To date, RE has been extensively studied among male East African distance runners. By contrast, there is a paucity of data on the RE of female East African runners. A total of 10 female Kenyan runners performed 3 × 1,600-m steady-state run trials on a flat outdoor clay track (400-m lap) at the intensities that corresponded to their everyday training intensities for easy, moderate, and fast running. Running economy together with gait characteristics was determined. Participants showed moderate to very good RE at the first (202 ± 26 ml·kg·km) and second (188 ± 12 ml·kg·km) run trials, respectively. Correlation analysis revealed significant relationship between ground contact time (GCT) and RE at the second run (r = 0.782; p = 0.022), which represented the intensity of anaerobic threshold. This study is the first to report the RE and gait characteristics of East African female athletes measured under everyday training settings. We provided the evidence that GCT is associated with the superior RE of the female Kenyan runners.

  11. Physiological and molecular analysis of selected Kenyan maize lines for aluminum tolerance

    USDA-ARS?s Scientific Manuscript database

    Aluminum (Al) toxicity is an important limitation to maize production in many tropical and sub-tropical acid soil areas. The aim of this study was to survey the variation in Al tolerance in a panel of maize lines adapted for Kenya and look for novel sources of Al tolerance. 112 Kenyan maize accessio...

  12. Conducting Action Research in Kenyan Primary Schools: A Narrative of Lived Experiences

    ERIC Educational Resources Information Center

    Otienoh, Ruth

    2015-01-01

    This paper is a narrative of my personal experiences of conducting action research in Kenyan primary schools. It highlights the opportunities, successes, challenges and dilemmas I encountered during the process: from the school hunting period, to the carrying out of the actual research in two schools, with four teachers. This study reveals that…

  13. A technique for extracting blood samples from mice in fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  14. Anti-bacterial efficacy of alcoholic hand rubs in the Kenyan market, 2015.

    PubMed

    Ochwoto, Missiani; Muita, Lucy; Talaam, Keith; Wanjala, Cecilia; Ogeto, Frank; Wachira, Faith; Osman, Saida; Kimotho, James; Ndegwa, Linus

    2017-01-01

    Hand hygiene is known to be effective in preventing hospital and community-acquired infections. The increasing number of hand sanitizer brands in Kenyan hospitals and consumer outlets is of concern. Thus the main aim of this study was to evaluate the anti-bacterial efficacy and organoleptic properties of these hand sanitizers in Kenya. This was an experimental, laboratory-based study of 14 different brands of hand sanitizers (coded HS1-14) available in various retail outlets and hospitals in Kenya. Efficacy was evaluated using standard non-pathogenic Escherichia coli (ATCC 25922), Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) as per the European Standard (EN). The logarithmic reduction factors (RF) were assessed at baseline and after treatment, and log reduction then calculated. Ten and 25 healthy volunteers participated in the efficacy and organoleptic studies respectively. Four (28.6%) hand sanitizers (HS12, HS9, HS13 and HS14) showed a 5.9 reduction factor on all the three bacteria strains. Seven (50%) hand sanitizers had efficacies of <3 against all the three bacteria strains used. Efficacy on E. Coli was higher compared to the other pathogens. Three hand sanitizers were efficacious on one of the pathogens and not the other. In terms of organoleptic properties, gel-based formulations were rated far higher than the liquid based formulations brands. Fifty percent (50%) of the selected hand sanitizers in the Kenyan market have efficacy that falls below the World Health Organization (WHO) and DIN EN 1500:2013. Of the 14 hand sanitizers found in the Kenyan market, only four showed efficacies that were comparable to the WHO-formulation. There is a need to evaluate how many of these products with <3 efficacy that have been incorporated into the health system for hand hygiene and the country's policy on regulations on their usage.

  15. Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods.

    PubMed

    Piruzan, Elham; Haghighatafshar, Mahdi; Faghihi, Reza; Entezarmahdi, Seyed Mohammad

    2016-03-01

    Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients' blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine.

  16. Determinants of Non-Compliance of Public Procurement Regulations in Kenyan Secondary Schools

    ERIC Educational Resources Information Center

    Migosi, Joash; Ombuki, Charles; Ombuki, Kennedy N.; Evusa, Zablon

    2013-01-01

    Kenya's public procurement and disposal Act of 2005 sets out clear rules and procedures for public procurement entities to follow; however this does not seem to be the case. This study sought to examine determinants of Non-compliance to the Public Procurement Regulations in Kenyan Secondary Schools. The study adopted a descriptive survey research.…

  17. Optimizing cord blood sample cryopreservation.

    PubMed

    Harris, David T

    2012-03-01

    Cord blood (CB) banking is becoming more and more commonplace throughout the medical community, both in the USA and elsewhere. It is now generally recognized that storage of CB samples in multiple aliquots is the preferred approach to banking because it allows the greatest number of uses of the sample. However, it is unclear which are the best methodologies for cryopreservation and storage of the sample aliquots. In the current study we analyzed variables that could affect these processes. CB were processed into mononuclear cells (MNC) and frozen in commercially available human serum albumin (HSA) or autologous CB plasma using cryovials of various sizes and cryobags. The bacteriophage phiX174 was used as a model virus to test for cross-contamination. We observed that cryopreservation of CB in HSA, undiluted autologous human plasma and 50% diluted plasma was equivalent in terms of cell recovery and cell viability. We also found that cryopreservation of CB samples in either cryovials or cryobags displayed equivalent thermal characteristics. Finally, we demonstrated that overwrapping the CB storage container in an impermeable plastic sheathing was sufficient to prevent cross-sample viral contamination during prolonged storage in the liquid phase of liquid nitrogen dewar storage. CB may be cryopreserved in either vials or bags without concern for temperature stability. Sample overwrapping is sufficient to prevent microbiologic contamination of the samples while in liquid-phase liquid nitrogen storage.

  18. Astronaut Joseph Kerwin takes blood sample from Astronaut Charles Conrad

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Scientist-Astronaut Joseph P. Kerwin (right), Skylab 2 science pilot and a doctor of medicine, takes a blood sample from Astronaut Charles Conrad Jr., Sylab 2 commander, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. The blood sampling was part of the Skylab Hematology and Immunology Experiment M110 series.

  19. Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods

    PubMed Central

    Piruzan, Elham; Haghighatafshar, Mahdi; Faghihi, Reza; Entezarmahdi, Seyed Mohammad

    2016-01-01

    Abstract Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients’ blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine. PMID:26986171

  20. Vascular Blood Collection protocol samples into MELFI

    NASA Image and Video Library

    2011-10-18

    iss029e028495 (10/18/2011) --- Japan Aerospace Exploration Agency astronaut Satoshi Furukawa,Expedition 29 flight engineer,prepares to put samples from the CSA (Canadian Space Agency) Vascular Blood Collection protocol into the MELFI-1 (Minus Eighty Laboratory Freezer for ISS 1) unit.

  1. Translingualism, Kenyan Hip-Hop and Emergent Ethnicities: Implications for Language Theory and Pedagogy

    ERIC Educational Resources Information Center

    Milu, Esther

    2018-01-01

    This article reports on preliminary findings of three prominent Kenyan hip-hop artists, Jua Cali, Abbas Kubaff, and Nazizi Hirji, as they theorize and construct emergent ethnicities vis-à-vis their translingual practices. Using in-depth phenomenological interviews, observations of their everyday language use, and analysis of their language choices…

  2. An Anthropocentric Approach to Saving Biodiversity: Kenyan Pupils' Attitudes towards Parks and Wildlife

    ERIC Educational Resources Information Center

    Ali, Ibrahim M.

    2006-01-01

    This study used an unobtrusive attitude survey and questionnaires to investigate Kenyan pupils' attitudes towards parks and wildlife. The positive attitudes found result from their understanding of the link between these resources and their own wellbeing. The sentiments about parks and wildlife expressed by the pupils are an extraction of the…

  3. Human blood RNA stabilization in samples collected and transported for a large biobank

    PubMed Central

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  4. A simple technic for repeated collection of blood samples from mice.

    PubMed

    Stoltz, D R; Bendall, R D

    1975-06-01

    A device for repeated collection of small blood samples from mice was constructed from a plastic syringe. Blood was collected into a 3.33 lambda capillary tube. Bleeding was stopped by a hemostat made from a rubber stopper. This technic allows easy collection of approximately 20 serial samples within an 8-hr period.

  5. Coagulation dynamics of a blood sample by multiple scattering analysis

    NASA Astrophysics Data System (ADS)

    Faivre, Magalie; Peltié, Philippe; Planat-Chrétien, Anne; Cosnier, Marie-Line; Cubizolles, Myriam; Nougier, Christophe; Négrier, Claude; Pouteau, Patrick

    2011-05-01

    We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.

  6. `No One Should Destroy the Forest': Using photo-based vignette interviews to understand Kenyan teachers' views of the environment

    NASA Astrophysics Data System (ADS)

    Quigley, Cassie F.; Miller, Zachary D.; Dogbey, James; Che, S. Megan; Hallo, Jeffrey

    2014-11-01

    In the midst of the current environmental crisis, scientists, academics, authors, and politicians worldwide are urging citizens to create sustainable communities. However, there is little capability to build a sustainable society without an informed, active, and engaged populous. This requires more than just environmentally knowledgeable citizens. It requires a society that understands the principles of the environment and can also exemplify them in daily life. In order to create a more environmentally literate world, there has been a push for environmental education integrated into schools. This qualitative study sought to examine Kenyan teachers' perspectives on the human-nature interaction by conducting vignette focus-group interviews. It is a subject not widely explored but vital for conservation not only in this area, but also other areas that seek to have an ecological informed populous. The vignettes were created using photographs and explanations of the photographs that the participants collected and emailed to the authors. For the focus-group vignette interviews, there were a total of 55 participants (30 females and 25 males). After InVivo analysis, we had 6 codes (resentment, pride, perils, blame, pragmatism, and self-interested) within 3 major themes. This study has implications for informing science education to combat these traditions of subjecting students to a science curriculum that demotes Kenyan cultural heritage and lifestyle. By incorporating local knowledge such as the ideas discussed in this paper into Kenyan science education, Kenyans can reach one of most challenging objectives of education, which is to produce children who are fundamentally aware of their environment.

  7. Sampling methods to the statistical control of the production of blood components.

    PubMed

    Pereira, Paulo; Seghatchian, Jerard; Caldeira, Beatriz; Santos, Paula; Castro, Rosa; Fernandes, Teresa; Xavier, Sandra; de Sousa, Gracinda; de Almeida E Sousa, João Paulo

    2017-12-01

    The control of blood components specifications is a requirement generalized in Europe by the European Commission Directives and in the US by the AABB standards. The use of a statistical process control methodology is recommended in the related literature, including the EDQM guideline. The control reliability is dependent of the sampling. However, a correct sampling methodology seems not to be systematically applied. Commonly, the sampling is intended to comply uniquely with the 1% specification to the produced blood components. Nevertheless, on a purely statistical viewpoint, this model could be argued not to be related to a consistent sampling technique. This could be a severe limitation to detect abnormal patterns and to assure that the production has a non-significant probability of producing nonconforming components. This article discusses what is happening in blood establishments. Three statistical methodologies are proposed: simple random sampling, sampling based on the proportion of a finite population, and sampling based on the inspection level. The empirical results demonstrate that these models are practicable in blood establishments contributing to the robustness of sampling and related statistical process control decisions for the purpose they are suggested for. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device

    PubMed Central

    Boardman, Anna K.; Campbell, Jennifer; Wirz, Holger; Sharon, Andre; Sauer-Budge, Alexis F.

    2015-01-01

    Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1–100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detection. Current culture-based methods can take a minimum of two days, while faster methods like PCR require a sample free of inhibitors (i.e., blood components). Though commercial kits exist for the removal of blood from these samples, they typically capture only DNA, thereby necessitating the use of blood culture for antimicrobial testing. Here, we report a novel, scaled-up sample preparation protocol carried out in a new microbial concentration device. The process can efficiently lyse 10 mL of bacteremic blood while maintaining the microorganisms’ viability, giving a 30‑μL final output volume. A suite of six microorganisms (Staphylococcus aureus, Streptococcus pneumoniae, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, and Candida albicans) at a range of clinically relevant concentrations was tested. All of the microorganisms had recoveries greater than 55% at the highest tested concentration of 100 CFU/mL, with three of them having over 70% recovery. At the lowest tested concentration of 3 CFU/mL, two microorganisms had recoveries of ca. 40–50% while the other four gave recoveries greater than 70%. Using a Taqman assay for methicillin-sensitive S. aureus (MSSA)to prove the feasibility of downstream analysis, we show that our microbial pellets are clean enough for PCR amplification. PCR testing of 56 spiked-positive and negative samples gave a specificity of 0.97 and a sensitivity of 0.96, showing that our sample preparation protocol holds great promise for the rapid diagnosis of bacteremia directly from a primary sample. PMID:25675242

  9. RNA-Stabilized Whole Blood Samples but Not Peripheral Blood Mononuclear Cells Can Be Stored for Prolonged Time Periods Prior to Transcriptome Analysis

    PubMed Central

    Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea

    2011-01-01

    Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280

  10. Are They Bloody Guilty? Blood Doping with Simulated Samples

    ERIC Educational Resources Information Center

    Stuart, Parker E.; Lees, Kelsey D.; Milanick, Mark A.

    2014-01-01

    In this practice-based lab, students are provided with four Olympic athlete profiles and simulated blood and urine samples to test for illegal substances and blood-doping practices. Throughout the course of the lab, students design and conduct a testing procedure and use their results to determine which athletes won their medals fairly. All of the…

  11. From Attitudes to Practice: Utilising Inclusive Teaching Strategies in Kenyan Primary Schools

    ERIC Educational Resources Information Center

    Elder, Brent C.; Damiani, Michelle L.; Oswago, Benson O.

    2016-01-01

    The purpose of this paper is to provide evidence of Kenyan primary school teachers using inclusive teaching strategies in a rural setting with many known barriers to the development of a sustainable inclusive education system. This qualitative study examines teachers' uses of inclusive teaching strategies in primary schools following a series of…

  12. Otitis Media and Its Sequelae in Kenyan Schoolchildren.

    PubMed

    Simões, Eric A F; Kiio, Francis; Carosone-Link, Phyllis J; Ndegwa, Serah N; Ayugi, John; Macharia, Isaac M

    2016-12-01

    The goal of this study was to obtain representative Kenyan data on the point prevalence of acute otitis media (AOM) and its sequelae (otitis media with effusion [OME] and chronic suppurative otitis media [CSOM]), a major cause of preventable hearing loss in children in developing countries. In Africa, there are limited studies on the prevalence of AOM and its sequelae in children. Study subjects were children aged 2 to 15 years and were enrolled from randomly selected preprimary and primary schools. After parental or guardian consent, subjects had a questionnaire administered, otoscopy and tympanometry were done, and audiometry was performed on those with ear problems detected on these examinations. A total of 9825 (75%) children was from rural schools. The prevalence of CSOM was 15 of 1000, OME was 15 of 1000, and AOM was 7 of 1000 children. Rural Rift Valley schoolchildren had the highest prevalence of CSOM (24 of 1000) compared with other regions (12 of 1000; P < .0001). Ear discharge occurred before 3.5 years in 50% of 901 children with ear discharge. A history of ear discharge was associated with abnormal tympanograms (odds ratio [OR], 11.9-19.2) and mild-to-severe hearing loss (OR, 21.6-38.6), even in children without ear disease (OR, 10.7-24.4). The burden of AOM sequelae in Kenyan preschool and schoolchildren is significant, and it occurs mostly in the first 4 years of life. By preventing early recurrent AOM, pneumococcal vaccination might partly avert nonreversible sequelae. © The Author 2015. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  13. Quantification of multiple elements in dried blood spot samples.

    PubMed

    Pedersen, Lise; Andersen-Ranberg, Karen; Hollergaard, Mads; Nybo, Mads

    2017-08-01

    Dried blood spots (DBS) is a unique matrix that offers advantages compared to conventional blood collection making it increasingly popular in large population studies. We here describe development and validation of a method to determine multiple elements in DBS. Elements were extracted from punches and analyzed using inductively coupled plasma-mass spectrometry (ICP-MS). The method was evaluated with quality controls with defined element concentration and blood spiked with elements to assess accuracy and imprecision. DBS element concentrations were compared with concentrations in venous blood. Samples with different hematocrit were spotted onto filter paper to assess hematocrit effect. The established method was precise and accurate for measurement of most elements in DBS. There was a significant but relatively weak correlation between measurement of the elements Mg, K, Fe, Cu, Zn, As and Se in DBS and venous whole blood. Hematocrit influenced the DBS element measurement, especially for K, Fe and Zn. Trace elements can be measured with high accuracy and low imprecision in DBS, but contribution of signal from the filter paper influences measurement of some elements present at low concentrations. Simultaneous measurement of K and Fe in DBS extracts may be used to estimate sample hematocrit. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. A comparative analysis of media reporting of perceived risks and benefits of genetically modified crops and foods in Kenyan and international newspapers.

    PubMed

    DeRosier, Christopher; Sulemana, Iddisah; James, Harvey S; Valdivia, Corinne; Folk, William; Smith, Randall D

    2015-07-01

    We empirically examine the reporting on biotechnology in Kenyan and international newspapers between 2010 and early 2014. We identify news articles that reported on biotechnology and analyze their use of words to determine whether there is a balance in the reporting of perceived risks and benefits. We also consider how the sources used in news articles and how the publication of the Séralini study of rats fed genetically modified maize affect the balance of reporting of perceived risks and benefits. We find that in Kenyan news reporting, more articles mention perceived benefits than risks, but when risks are mentioned, new articles contain more references to risks than to benefits. We also find that sources affect the reporting of perceived risks and benefits and that the Séralini study increased the likelihood that perceived risks are reported in Kenyan news reporting, but not in international newspapers. © The Author(s) 2015.

  15. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  16. Civil unrest and birthweight: an exploratory analysis of the 2007/2008 Kenyan Crisis.

    PubMed

    Bell, Suzanne; Prata, Ndola; Lahiff, Maureen; Eskenazi, Brenda

    2012-05-01

    For decades, Africa has been plagued by political and ethnic conflict, the health ramifications of which are often not investigated. A crisis occurred recently in Kenya following the 2007 presidential election. Ethnic violence ensued, targeting the incumbent President Kibaki's Kikuyu people. The violence occurred primarily in Nairobi and the Rift Valley of Kenya. We sought to examine the association between exposure to the 2007/2008 Kenyan Crisis and birthweight. Using the 2008/2009 Kenyan Demographic and Health Survey (KDHS), we compared birthweights of infants in utero or not yet conceived during the 15 months after the political turmoil following the 2007 presidential election (exposed) to those who were born before the crisis (unexposed). There were 663 "exposed" and 687 "unexposed" infants. Multivariate regression was used. We examined the possibility of two-way and three-way interactions between exposure status, ethnicity (Kikuyu versus non-Kikuyu), and region (violent region versus not). Overall, exposure to the Kenyan Crisis was associated with lower birthweight. Kikuyu women living in a violent region who were exposed during their 2nd trimester had the greatest difference in birthweight in comparison to all unexposed infants: 564.4g lower (95% CI 285.1, 843.6). Infants of Kikuyu exposed during the 2nd trimester and living in a violent region weighed 603.6g less (95% CI 333.6, 873.6) than Kikuyu infants born during the unexposed period. Political unrest may have implications for the birthweight of infants, particularly among targeted populations. Given the adverse sequelae associated with lowered birthweight, these results suggest that particular attention should be paid to pregnant women and targeted ethnic groups following such events. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Education Quality and the Kenyan 8-4-4 Curriculum: Secondary School Learners' Experiences

    ERIC Educational Resources Information Center

    Milligan, Lizzi O.

    2017-01-01

    This article explores the implementation of Kenyan secondary education in rural Western Kenya, focusing on learners' experiences. One of the key challenges to educational quality is shown to be the size and breadth of the secondary education curriculum. Learners are in school 12 hours a day with those approaching their final exams working three to…

  18. Changing Pedagogical Practice in Kenyan Primary Schools: The Impact of School-Based Training

    ERIC Educational Resources Information Center

    Hardman, Frank; Abd-Kadir, Jan; Agg, Catherine; Migwi, James; Ndambuku, Jacinta; Smith, Fay

    2009-01-01

    This study reports on an investigation into the impact of a national, school-based teacher development programme on learning and teaching in Kenyan primary schools. Building on a national baseline study (n=102), 144 video-recorded lessons, covering the teaching of English, maths and science at Standards 3 and 6, were analysed to investigate…

  19. Use of Capillary Blood Samples Leads to Higher Parasitemia Estimates and Higher Diagnostic Sensitivity of Microscopic and Molecular Diagnostics of Malaria than Venous Blood Samples.

    PubMed

    Mischlinger, Johannes; Pitzinger, Paul; Veletzky, Luzia; Groger, Mirjam; Zoleko-Manego, Rella; Adegnika, Ayola A; Agnandji, Selidji T; Lell, Bertrand; Kremsner, Peter G; Tannich, Egbert; Mombo-Ngoma, Ghyslain; Mordmüller, Benjamin; Ramharter, Michael

    2018-05-25

    Diagnosis of malaria is usually based on samples of peripheral blood. However, it is unclear whether capillary (CAP) or venous (VEN) blood samples provide better diagnostic performance. Quantitative differences of parasitemia between CAP and VEN blood and diagnostic performance characteristics were investigated. Patients were recruited between September 2015 and February 2016 in Gabon. Light microscopy and qPCR quantified parasitemia of paired CAP and VEN samples, whose preparation followed the exact same methodology. CAP and VEN performance characteristics using microscopy were evaluated against a qPCR gold-standard. Microscopy revealed a median (IQR) parasites/L of 495 (853,243) in CAP and 429 (524,074) in VEN samples manifesting in a +16.6% (p=0.04) higher CAPparasitemia compared with VENparasitemia. Concordantly, qPCR demonstrated that -0.278 (p=0.006) cycles were required for signal detection in CAP samples. CAPsensitivity of microscopy relative to the gold-standard was 81.5% (77.485.6%) versus VENsensitivity of 73.4% (68.878.1%), while CAPspecificity and VENspecificity were 91%. CAPsensitivity and VENsensitivity dropped to 63.3% and 45.9%, respectively for a sub-population of low-level parasitemias while specificities were 92%. CAP sampling leads to higher parasitemias compared to VEN sampling and improves diagnostic sensitivity. These findings may have important implications for routine diagnostics, research and elimination campaigns of malaria.

  20. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation.

    PubMed

    Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo

    2008-02-01

    Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.

  1. Adaptive control of theophylline therapy: importance of blood sampling times.

    PubMed

    D'Argenio, D Z; Khakmahd, K

    1983-10-01

    A two-observation protocol for estimating theophylline clearance during a constant-rate intravenous infusion is used to examine the importance of blood sampling schedules with regard to the information content of resulting concentration data. Guided by a theory for calculating maximally informative sample times, population simulations are used to assess the effect of specific sampling times on the precision of resulting clearance estimates and subsequent predictions of theophylline plasma concentrations. The simulations incorporated noise terms for intersubject variability, dosing errors, sample collection errors, and assay error. Clearance was estimated using Chiou's method, least squares, and a Bayesian estimation procedure. The results of these simulations suggest that clinically significant estimation and prediction errors may result when using the above two-point protocol for estimating theophylline clearance if the time separating the two blood samples is less than one population mean elimination half-life.

  2. The Status and Roles of Ghanaian and Kenyan Women: Implications for Fertility Behavior.

    ERIC Educational Resources Information Center

    Germain, Adrienne; Smock, Audrey

    Kenya and Ghana provide interesting case studies of the theory that women who have access to roles other than mother and whose status does not depend largely or solely on the number of children they bear will have fewer children. Kenyan and Ghanaian women have among the highest desired and actual fertility in the world. They also, relatively…

  3. The Experience of Patriarchy by Kenyan Women in the Pursuit of Higher Education

    ERIC Educational Resources Information Center

    Machira, Mary Achieng

    2013-01-01

    Low enrollment of women in higher education is a problem in Africa, particularly in Kenya, where despite the government's introduction of affirmative action, female enrollment averages only 36.7% at public universities. This gender gap may be due to the patriarchal influence in Kenyan society, where the role of women is seen as child-bearing,…

  4. Maternal health services utilisation by Kenyan adolescent mothers: Analysis of the Demographic Health Survey 2014.

    PubMed

    Banke-Thomas, Aduragbemi; Banke-Thomas, Oluwasola; Kivuvani, Mwikali; Ameh, Charles Anawo

    2017-06-01

    Kenya has one of the highest adolescent fertility rates in East-Africa, estimated at 106 births per 1000 females aged 15-19years. In addition to promoting safe sexual behaviour, utilisation of maternal health services (MHS) is essential to prevent poor outcomes of pregnancy and childbirth. To ensure optimum planning, particularly in the context of the Sustainable Development Goals, this study assesses the current service utilisation patterns of Kenyan adolescent mothers and the factors that affect this utilisation. Using data from the recently published 2014 Kenya Demographic Health Survey, we collected demographic and utilisation data of all three MHSs (antenatal care (ANC), skilled birth attendance (SBA) and postnatal care (PNC)) of adolescent mothers aged 15-19years. We then conducted bivariate and multivariate analyses to test associations between selected demographic and service utilisation variables. Our findings showed that half of Kenyan adolescent mothers have had their first birth by the age of 16. MHS utilisation rates amongst Kenyan adolescent mothers were 93%, 65%, 92% for ANC, SBA and PNC respectively. Mother's education, religion, ethnicity, place of residence, wealth quintile, mass media exposure, and geographical region were significant predictors for both ANC and SBA utilisation. Education level of partner was significant for ANC utilisation while parity was significant for both SBA and PNC. Adolescent MHS utilisation is not optimum in Kenya. More work that includes affordable care provision, cultural re-orientation, targeted mass-media campaigns and male involvement in care need to be done with emphasis on the most disadvantaged areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Cost Evaluation of Dried Blood Spot Home Sampling as Compared to Conventional Sampling for Therapeutic Drug Monitoring in Children

    PubMed Central

    Martial, Lisa C.; Aarnoutse, Rob E.; Schreuder, Michiel F.; Henriet, Stefanie S.; Brüggemann, Roger J. M.; Joore, Manuela A.

    2016-01-01

    Dried blood spot (DBS) sampling for the purpose of therapeutic drug monitoring can be an attractive alternative for conventional blood sampling, especially in children. This study aimed to compare all costs involved in conventional sampling versus DBS home sampling in two pediatric populations: renal transplant patients and hemato-oncology patients. Total costs were computed from a societal perspective by adding up healthcare cost, patient related costs and costs related to loss of productivity of the caregiver. Switching to DBS home sampling was associated with a cost reduction of 43% for hemato-oncology patients (€277 to €158) and 61% for nephrology patients (€259 to €102) from a societal perspective (total costs) per blood draw. From a healthcare perspective, costs reduced with 7% for hemato-oncology patients and with 21% for nephrology patients. Total savings depend on the number of hospital visits that can be avoided by using home sampling instead of conventional sampling. PMID:27941974

  6. Cost Evaluation of Dried Blood Spot Home Sampling as Compared to Conventional Sampling for Therapeutic Drug Monitoring in Children.

    PubMed

    Martial, Lisa C; Aarnoutse, Rob E; Schreuder, Michiel F; Henriet, Stefanie S; Brüggemann, Roger J M; Joore, Manuela A

    2016-01-01

    Dried blood spot (DBS) sampling for the purpose of therapeutic drug monitoring can be an attractive alternative for conventional blood sampling, especially in children. This study aimed to compare all costs involved in conventional sampling versus DBS home sampling in two pediatric populations: renal transplant patients and hemato-oncology patients. Total costs were computed from a societal perspective by adding up healthcare cost, patient related costs and costs related to loss of productivity of the caregiver. Switching to DBS home sampling was associated with a cost reduction of 43% for hemato-oncology patients (€277 to €158) and 61% for nephrology patients (€259 to €102) from a societal perspective (total costs) per blood draw. From a healthcare perspective, costs reduced with 7% for hemato-oncology patients and with 21% for nephrology patients. Total savings depend on the number of hospital visits that can be avoided by using home sampling instead of conventional sampling.

  7. Iron in Micronutrient Powder Promotes an Unfavorable Gut Microbiota in Kenyan Infants

    PubMed Central

    Tang, Minghua; Frank, Daniel N.; Hendricks, Audrey E.; Ir, Diana; Esamai, Fabian; Liechty, Edward; Hambidge, K. Michael; Krebs, Nancy F.

    2017-01-01

    Iron supplementation may have adverse health effects in infants, probably through manipulation of the gut microbiome. Previous research in low-resource settings have focused primarily on anemic infants. This was a double blind, randomized, controlled trial of home fortification comparing multiple micronutrient powder (MNP) with and without iron. Six-month-old, non- or mildly anemic, predominantly-breastfed Kenyan infants in a rural malaria-endemic area were randomized to consume: (1) MNP containing 12.5 mg iron (MNP+Fe, n = 13); (2) MNP containing no iron (MNP−Fe, n = 13); or (3) Placebo (CONTROL, n = 7), from 6–9 months of age. Fecal microbiota were profiled by high-throughput bacterial 16S rRNA gene sequencing. Markers of inflammation in serum and stool samples were also measured. At baseline, the most abundant phylum was Proteobacteria (37.6% of rRNA sequences). The proteobacterial genus Escherichia was the most abundant genus across all phyla (30.1% of sequences). At the end of the intervention, the relative abundance of Escherichia significantly decreased in MNP−Fe (−16.05 ± 6.9%, p = 0.05) and CONTROL (−19.75 ± 4.5%, p = 0.01), but not in the MNP+Fe group (−6.23 ± 9%, p = 0.41). The second most abundant genus at baseline was Bifidobacterium (17.3%), the relative abundance of which significantly decreased in MNP+Fe (−6.38 ± 2.5%, p = 0.02) and CONTROL (−8.05 ± 1.46%, p = 0.01), but not in MNP-Fe (−4.27 ± 5%, p = 0.4445). Clostridium increased in MNP-Fe only (1.9 ± 0.5%, p = 0.02). No significant differences were observed in inflammation markers, except for IL-8, which decreased in CONTROL. MNP fortification over three months in non- or mildly anemic Kenyan infants can potentially alter the gut microbiome. Consistent with previous research, addition of iron to the MNP may adversely affect the colonization of potential beneficial microbes and attenuate the decrease of potential pathogens. PMID:28753958

  8. Reflections from a Computer Simulations Program on Cell Division in Selected Kenyan Secondary Schools

    ERIC Educational Resources Information Center

    Ndirangu, Mwangi; Kiboss, Joel K.; Wekesa, Eric W.

    2005-01-01

    The application of computer technology in education is a relatively new approach that is trying to justify inclusion in the Kenyan school curriculum. Being abstract, with a dynamic nature that does not manifest itself visibly, the process of cell division has posed difficulties for teachers. Consequently, a computer simulation program, using…

  9. A content validated questionnaire for assessment of self reported venous blood sampling practices

    PubMed Central

    2012-01-01

    Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward. PMID:22260505

  10. A content validated questionnaire for assessment of self reported venous blood sampling practices.

    PubMed

    Bölenius, Karin; Brulin, Christine; Grankvist, Kjell; Lindkvist, Marie; Söderberg, Johan

    2012-01-19

    Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  11. Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples

    PubMed Central

    2011-01-01

    Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640

  12. Comparison of three methods of sampling trout blood for measurements of hematocrit

    USGS Publications Warehouse

    Steucke, Erwin W.; Schoettger, Richard A.

    1967-01-01

    Trout blood is frequently collected for hematocrit measurements by excising the caudal fin (Snieszko, 1960), but this technique is impractical if valuable fish are to be sampled or if repeated observations are desired. Schiffman (1959) and Snieszko (1960) collected blood from the dorsal aorta and the heart, but these methods are relatively slow and require the preparation of needles and syringes. The use of pointed capillary tubes for cardiac punctures increases the speed of sampling, but body fluids may dilute the blood (Perkins, 1957; Larsen and Snieszko, 1961; and Normandau, 1962). There is need for methods of sampling which are rapid and which neither influence hematological determinations nor harm the fish.

  13. Challenges and coping strategies of parents of children with autism on the Kenyan coast.

    PubMed

    Gona, Joseph K; Newton, Charles R; Rimba, Kenneth K; Mapenzi, Rachel; Kihara, Michael; Vijver, Fonns V; Abubakar, Amina

    2016-01-01

    Research on the challenges of raising a child with autism is mostly conducted in Europe, North America and Australia, and has revealed that parents have to come to terms with living with a lifelong developmental disability. In addition, parents are faced with numerous concerns, such as caring burdens, poor prognosis, and negative public attitudes. Virtually no research has been conducted in Africa on this subject. Thirty-seven interviews and eight focus group discussions were conducted with parents of children with autism and professionals in regular contact with these parents from rural and urban counties of the Kenyan coast. The study investigated challenges faced by parents and how they cope with those challenges. A purposive-convenience sampling procedure was used in selecting the study participants. A digital recorder was used to record all the interviews and focus group discussions. Transcriptions were done in Swahili, translated into English, and then imported to the NVivo software program for content analysis. The results indicate that parents of children with autism on the Kenyan coast experience common challenges including stigma, lack of appropriate treatment, financial and caring burdens regardless of their religious and cultural backgrounds. Coping strategies applied by parents comprised problem-focused aspects that involve diet management and respite care, and emotion-focused aspects that consist of beliefs in supernatural powers, prayers and spiritual healing. This qualitative study reveals a range of challenges that could have significant impact when caring for a child with autism. Coping strategies applied by parents target the physical health of the child and the psychological wellbeing of the parent. Consideration of these outcomes is vital as they could impact the initiation of a community-based rehabilitation service delivery in rural settings where parents play an active role.

  14. Challenges and coping strategies of parents of children with autism on the Kenyan coast

    PubMed Central

    Gona, JK; Newton, CR; Rimba, KK; Mapenzi, R; Kihara, M; Vijver, FV; Abubakar, A

    2017-01-01

    Introduction Research on the challenges of raising a child with autism is mostly conducted in Europe, North America and Australia, and has revealed that parents have to come to terms with living with a lifelong developmental disability. In addition, parents are faced with numerous concerns, such as caring burdens, poor prognosis, and negative public attitudes. Virtually no research has been conducted in Africa on this subject. Methods Thirty-seven interviews and eight focus group discussions were conducted with parents of children with autism and professionals in regular contact with these parents from rural and urban counties of the Kenyan coast. The study investigated challenges faced by parents and how they cope with those challenges. A purposive–convenience sampling procedure was used in selecting the study participants. A digital recorder was used to record all the interviews and focus group discussions. Transcriptions were done in Swahili, translated into English, and then imported to the NVivo software program for content analysis. Results The results indicate that parents of children with autism on the Kenyan coast experience common challenges including stigma, lack of appropriate treatment, financial and caring burdens regardless of their religious and cultural backgrounds. Coping strategies applied by parents comprised problem-focused aspects that involve diet management and respite care, and emotion-focused aspects that consist of beliefs in supernatural powers, prayers and spiritual healing. Conclusions This qualitative study reveals a range of challenges that could have significant impact when caring for a child with autism. Coping strategies applied by parents target the physical health of the child and the psychological wellbeing of the parent. Consideration of these outcomes is vital as they could impact the initiation of a community-based rehabilitation service delivery in rural settings where parents play an active role. PMID:27098766

  15. Umbilical Arterial Blood Sampling Alters Cerebral Tissue Oxygenation in Very Low Birth Weight Neonates.

    PubMed

    Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F

    2015-11-01

    To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Algorithm-based arterial blood sampling recognition increasing safety in point-of-care diagnostics.

    PubMed

    Peter, Jörg; Klingert, Wilfried; Klingert, Kathrin; Thiel, Karolin; Wulff, Daniel; Königsrainer, Alfred; Rosenstiel, Wolfgang; Schenk, Martin

    2017-08-04

    To detect blood withdrawal for patients with arterial blood pressure monitoring to increase patient safety and provide better sample dating. Blood pressure information obtained from a patient monitor was fed as a real-time data stream to an experimental medical framework. This framework was connected to an analytical application which observes changes in systolic, diastolic and mean pressure to determine anomalies in the continuous data stream. Detection was based on an increased mean blood pressure caused by the closing of the withdrawal three-way tap and an absence of systolic and diastolic measurements during this manipulation. For evaluation of the proposed algorithm, measured data from animal studies in healthy pigs were used. Using this novel approach for processing real-time measurement data of arterial pressure monitoring, the exact time of blood withdrawal could be successfully detected retrospectively and in real-time. The algorithm was able to detect 422 of 434 (97%) blood withdrawals for blood gas analysis in the retrospective analysis of 7 study trials. Additionally, 64 sampling events for other procedures like laboratory and activated clotting time analyses were detected. The proposed algorithm achieved a sensitivity of 0.97, a precision of 0.96 and an F1 score of 0.97. Arterial blood pressure monitoring data can be used to perform an accurate identification of individual blood samplings in order to reduce sample mix-ups and thereby increase patient safety.

  17. Bacterial and fungal DNA extraction from blood samples: automated protocols.

    PubMed

    Lorenz, Michael G; Disqué, Claudia; Mühl, Helge

    2015-01-01

    Automation in DNA isolation is a necessity for routine practice employing molecular diagnosis of infectious agents. To this end, the development of automated systems for the molecular diagnosis of microorganisms directly in blood samples is at its beginning. Important characteristics of systems demanded for routine use include high recovery of microbial DNA, DNA-free containment for the reduction of DNA contamination from exogenous sources, DNA-free reagents and consumables, ideally a walkaway system, and economical pricing of the equipment and consumables. Such full automation of DNA extraction evaluated and in use for sepsis diagnostics is yet not available. Here, we present protocols for the semiautomated isolation of microbial DNA from blood culture and low- and high-volume blood samples. The protocols include a manual pretreatment step followed by automated extraction and purification of microbial DNA.

  18. Identifying the potential of changes to blood sample logistics using simulation.

    PubMed

    Jørgensen, Pelle; Jacobsen, Peter; Poulsen, Jørgen Hjelm

    2013-01-01

    Using simulation as an approach to display and improve internal logistics at hospitals has great potential. This study shows how a simulation model displaying the morning blood-taking round at a Danish public hospital can be developed and utilized with the aim of improving the logistics. The focus of the simulation was to evaluate changes made to the transportation of blood samples between wards and the laboratory. The average- (AWT) and maximum waiting time (MWT) from a blood sample was drawn at the ward until it was received at the laboratory, and the distribution of arrivals of blood samples in the laboratory were used as the evaluation criteria. Four different scenarios were tested and compared with the current approach: (1) Using AGVs (mobile robots), (2) using a pneumatic tube system, (3) using porters that are called upon, or (4) using porters that come to the wards every 45 minutes. Furthermore, each of the scenarios was tested in terms of what amount of resources would give the optimal result. The simulations showed a big improvement potential in implementing a new technology/mean for transporting the blood samples. The pneumatic tube system showed the biggest potential lowering the AWT and MWT with approx. 36% and 18%, respectively. Additionally, all of the scenarios had a more even distribution of arrivals except for porters coming to the wards every 45 min. As a consequence of the results obtained in the study, the hospital decided to implement a pneumatic tube system.

  19. Rapid and reliable determination of the halogenating peroxidase activity in blood samples.

    PubMed

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2014-12-15

    By combining easy and fast leukocyte enrichment with aminophenyl-fluorescein (APF) staining we developed a method to quickly and specifically address the halogenating activity of the immunological relevant blood heme peroxidases myeloperoxidase and eosinophil peroxidase, respectively. For leukocyte enrichment a two-fold hypotonic lysis procedure of the blood with Millipore water was chosen which represents a cheap, fast and reliable method to diminish the amount of erythrocytes in the samples. This procedure is shown to be suitable both to human and murine blood micro-samples, making it also applicable to small animal experiments with recurring blood sampling. As all types of leukocytes are kept in the sample during the preparation, they can be analysed separately after discrimination during the flow cytometry analysis. This also holds for all heme peroxidase-containing cells, namely neutrophils, eosinophils and monocytes. Moreover additional parameters (e.g. antibody staining) can be combined with the heme peroxidase activity determination to gain additional information about the different immune cell types. Based on previous results we applied APF for specifically addressing the halogenating activity of leukocyte peroxidases in blood samples. This dye is selectively oxidized by the MPO and EPO halogenation products hypochlorous and hypobromous acid. This approach may provide a suitable tool to gain more insights into the immune-physiological role of the halogenating activity of heme peroxidases. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Payload specialist Reinhard Furrer show evidence of previous blood sampling

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Payload specialist Reinhard Furrer shows evidence of previous blood sampling while Wubbo J. Ockels, Dutch payload specialist (only partially visible), extends his right arm after a sample has been taken. Both men show bruises on their arms.

  1. Ambulatory blood pressure and blood lipids in a multiethnic sample of healthy adults.

    PubMed

    James, Gary D; Van Berge-Landry, Helene M; Morrison, Lynn A; Reza, Angela M; Nicolaisen, Nicola M; Bindon, James R; Brown, Daniel E

    2013-01-01

    Elevated blood pressure (BP), elevated serum cholesterol, and aberrant lipoprotein fractions (low levels of high-density lipoprotein (HDL) and high levels of low-density lipoprotein fractions and triglycerides) have all been used as measures that assess the "metabolic syndrome" and more recently in indexes of allostatic load, which are designed to assess the degree of integrated metabolic pathology. While there are ample data regarding the interrelationships of these measures in various pathophysiological settings, there are limited data regarding the interrelationship of ambulatory BP (ABP) and blood lipids in healthy subjects. The present study evaluates ABP-blood lipid relationships in a multiethnic sample of healthy adults. The subjects were 37 men (age = 40.9 ± 10.7 years) and 42 women (age = 35.8 ± 10.4 years) who were employed as hotel workers in Hawaii. Each wore an ABP monitor for one midweek workday and had pressures averaged in three daily microenvironments (work, home, and during sleep). They also had fasting blood samples taken for lipid profiling. Multivariate analysis of covariance shows that there was a strong inverse relationship between HDL and both systolic (P < 0.006) and diastolic (P < 0.006) BP, overall and in each microenvironment, but no statistically significant relationships with other lipid measures. These results suggest lipids and BP do not act as a group in healthy adults but that higher HDL is associated with lower BP. This latter finding is consistent with research that shows that HDL promotes vasodilation via its effect on endothelial nitric oxide synthase. Copyright © 2013 Wiley Periodicals, Inc.

  2. [DNA quantification of blood samples pre-treated with pyramidon].

    PubMed

    Zhu, Chuan-Hong; Zheng, Dao-Li; Ni, Rao-Zhi; Wang, Hai-Sheng; Ning, Ping; Fang, Hui; Liu, Yan

    2014-06-01

    To study DNA quantification and STR typing of samples pre-treated with pyramidon. The blood samples of ten unrelated individuals were anticoagulated in EDTA. The blood stains were made on the filter paper. The experimental groups were divided into six groups in accordance with the storage time, 30 min, 1 h, 3 h, 6 h, 12 h and 24h after pre-treated with pyramidon. DNA was extracted by three methods: magnetic bead-based extraction, QIAcube DNA purification method and Chelex-100 method. The quantification of DNA was made by fluorescent quantitative PCR. STR typing was detected by PCR-STR fluorescent technology. In the same DNA extraction method, the sample DNA decreased gradually with times after pre-treatment with pyramidon. In the same storage time, the DNA quantification in different extraction methods had significant differences. Sixteen loci DNA typing were detected in 90.56% of samples. Pyramidon pre-treatment could cause DNA degradation, but effective STR typing can be achieved within 24 h. The magnetic bead-based extraction is the best method for STR profiling and DNA extraction.

  3. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    PubMed

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Evaluation of a training DVD on pneumococcal conjugate vaccine for Kenyan EPI healthcare workers.

    PubMed

    Stokx, Jocelijn; Dochez, Carine; Ochieng, Pamela; Bahl, Jhilmil; Were, Fred

    2016-01-01

    The Kenyan Ministry of Public Health and Sanitation was the first in Africa to introduce the new 10-valent Pneumococcal Conjugate Vaccine, PCV-10, in 2011. For successful implementation and to avoid adverse events following immunisation, specific training on handling and storage of the PCV-10 vaccine was required. Therefore, a training DVD was recorded in English and partly in Kiswahili to be used in combination with in-classroom training. Since the Kenyan Immunisation Programme was the first to use a DVD for training healthcare workers, an evaluation was done to obtain feedback on content, format and use, and propose suggestions to improve quality and uptake of the DVD. Feedback was obtained from nurses and vaccinology course participants through the completion of a questionnaire. Nurses also participated in focus group discussions and trainers in key informant interviews. Twelve trainers, 72 nurses and 26 international vaccinology course participants provided feedback, with some notable differences between the three study groups. The survey results confirmed the acceptability of the content and format, and the feasibility of using the DVD in combination with in-classroom teaching. To improve the quality and adoption of the DVD, key suggestions were: Inclusion of all EPI vaccines and other important health issues; broad geographic distribution of the DVD; and bilingual English/Kiswahili use of languages or subtitles. The Kenyan DVD is appreciated by a heterogeneous and international audience rendering the DVD suitable for other Anglophone African countries. Differences between feedback from nurses and vaccinology course participants can be explained by the practical approach of the DVD and the higher education and service level of the latter. A drawback is the use of DVD players and televisions due to lack of electricity, but it is a matter of time before all rural health facilities in Africa will have access to electricity and modern technology.

  5. Interpreting Kenyan Science Teachers' Views about the Effect of Student Learning Experiences on Their Teaching

    ERIC Educational Resources Information Center

    Nashon, Samson Madera

    2013-01-01

    Analysis of views from a select group of Kenyan science teachers regarding the effect of student learning experiences on their teaching after implementing a contextualized science unit revealed that the teachers' (a) literal interpretation and adherence to the official curriculum conflicted with the students' desires to understand scientific…

  6. One mouse, one pharmacokinetic profile: quantitative whole blood serial sampling for biotherapeutics.

    PubMed

    Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M

    2014-07-01

    The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.

  7. Impact of Pre-analytic Blood Sample Collection Factors on Metabolomics.

    PubMed

    Townsend, Mary K; Bao, Ying; Poole, Elizabeth M; Bertrand, Kimberly A; Kraft, Peter; Wolpin, Brian M; Clish, Clary B; Tworoger, Shelley S

    2016-05-01

    Many epidemiologic studies are using metabolomics to discover markers of carcinogenesis. However, limited data are available on the influence of pre-analytic blood collection factors on metabolite measurement. We quantified 166 metabolites in archived plasma from 423 Health Professionals Follow-up Study and Nurses' Health Study participants using liquid chromatography-tandem mass spectrometry (LC-MS). We compared multivariable-adjusted geometric mean metabolite LC-MS peak areas across fasting time, season of blood collection, and time of day of blood collection categories. The majority of metabolites (160 of 166 metabolites) had geometric mean peak areas that were within 15% comparing samples donated after fasting 9 to 12 versus ≥13 hours; greater differences were observed in samples donated after fasting ≤4 hours. Metabolite peak areas generally were similar across season of blood collection, although levels of certain metabolites (e.g., bile acids and purines/pyrimidines) tended to be different in the summer versus winter months. After adjusting for fasting status, geometric mean peak areas for bile acids and vitamins, but not other metabolites, differed by time of day of blood collection. Fasting, season of blood collection, and time of day of blood collection were not important sources of variability in measurements of most metabolites in our study. However, considering blood collection variables in the design or analysis of studies may be important for certain specific metabolites, particularly bile acids, purines/pyrimidines, and vitamins. These results may be useful for investigators formulating analysis plans for epidemiologic metabolomics studies, including determining which metabolites to a priori exclude from analyses. Cancer Epidemiol Biomarkers Prev; 25(5); 823-9. ©2016 AACR. ©2016 American Association for Cancer Research.

  8. The Award of the PhD Degree in Kenyan Universities: A Quality Assurance Perspective

    ERIC Educational Resources Information Center

    Ayiro, Laban P.; Sang, James K.

    2011-01-01

    This article attempts to bring to the fore the need for enhanced quality assurance processes in the award of PhDs by Kenyan universities. The findings reveal that quality challenges exist in the institutional processes established for the award of this advanced degree across the universities in the country. It is hoped that the findings will stir…

  9. A Kenyan Cloud School. Massive Open Online & Ongoing Courses for Blended and Lifelong Learning

    ERIC Educational Resources Information Center

    Jobe, William

    2013-01-01

    This research describes the predicted outcomes of a Kenyan Cloud School (KCS), which is a MOOC that contains all courses taught at the secondary school level in Kenya. This MOOC will consist of online, ongoing subjects in both English and Kiswahili. The KCS subjects offer self-testing and peer assessment to maximize scalability, and digital badges…

  10. Writings of Lions: Narrative Inquiry of a Kenyan Couple Living in the U.S.

    ERIC Educational Resources Information Center

    Gilmore, Miranda; Miller, Marianne McInnes

    2013-01-01

    In this study, we told the story of a Kenyan couple, B. and F., who has left Kenya and moved to Southern California. We followed a narrative inquiry framework, using Clandinin and Connelly's (2000) guidelines. We delineated core components of narrative inquiry research, as well as related the journey of B. and F., who have created dual lives in…

  11. Multiple traumas, postelection violence, and posttraumatic stress among impoverished Kenyan youth.

    PubMed

    Harder, Valerie S; Mutiso, Victoria N; Khasakhala, Lincoln I; Burke, Heather M; Ndetei, David M

    2012-02-01

    Research on posttraumatic stress disorder (PTSD) among youth has focused on specific subgroups from developed countries. Most of the world's youth and war-like violence, however, is concentrated in developing countries, yet there is limited mental health data within affected countries. This study focused on a random community-based sample of 552 impoverished youth ages 6-18 within an informal settlement in Nairobi, Kenya, which experienced war-like violence for a month following the contested presidential election of 2007. Six months after the violence ended, 99 (18%) had PTSD according to the UCLA PTSD Reaction Index (Steinberg, Brymer, Decker, & Pynoos, 2004), and an additional 18 (3%) were found to have partial PTSD due to high overall scores. Kenyan psychologists conducted diagnostic interviews and found the positive predictive value of the assessment tool to be 72% in this sample; the confirmed prevalence was 12%. Similar to other studies worldwide, Criterion C (avoidance) was the limiting factor for diagnosing PTSD according to the DSM-IV-TR, and parent-child agreement was at best fair. The number of traumatic experiences was strongly associated with PTSD outcomes. Differences due to age or sex were not found. The findings indicate the need for universal mental health services for trauma-exposed youth and their families in the impoverished informal settlements of Nairobi, Kenya. Copyright © 2012 International Society for Traumatic Stress Studies.

  12. In vitro production of GHB in blood and serum samples under various storage conditions.

    PubMed

    Zörntlein, S W; Kopp, A; Becker, J; Kaufmann, T J; Röhrich, J; Urban, R

    2012-01-10

    The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly

  13. Blood Sampling in Newborns: A Systematic Review of YouTube Videos.

    PubMed

    Bueno, Mariana; Nishi, Érika Tihemi; Costa, Taine; Freire, Laís Machado; Harrison, Denise

    Objective of this study was to conduct a systematic review of YouTube videos showing neonatal blood sampling, and to evaluate pain management and comforting interventions used. Selected videos were consumer- or professional-produced videos showing human newborns undergoing heel lancing or venipuncture for blood sampling, videos showing the entire blood sampling procedure (from the first attempt or puncture to the time of application of a cotton ball or bandage), publication date prior to October 2014, Portuguese titles, available audio. Search terms included "neonate," "newborn," "neonatal screening," and "blood collection." Two reviewers independently screened the videos and extracted the following data. A total of 13 140 videos were retrieved, of which 1354 were further evaluated, and 68 were included. Videos were mostly consumer produced (97%). Heel lancing was performed in 62 (91%). Forty-nine infants (72%) were held by an adult during the procedure. Median pain score immediately after puncture was 4 (interquartile range [IQR] = 0-5), and median length of cry throughout the procedure was 61 seconds (IQR = 88). Breastfeeding (3%) and swaddling (1.5%) were rarely implemented. Posted YouTube videos in Portuguese of newborns undergoing blood collection demonstrate minimal use of pain treatment, and maximal distress during procedures. Knowledge translation strategies are needed to implement effective measures for neonatal pain relief and comfort.

  14. Direct and long-term detection of gene doping in conventional blood samples.

    PubMed

    Beiter, T; Zimmermann, M; Fragasso, A; Hudemann, J; Niess, A M; Bitzer, M; Lauer, U M; Simon, P

    2011-03-01

    The misuse of somatic gene therapy for the purpose of enhancing athletic performance is perceived as a coming threat to the world of sports and categorized as 'gene doping'. This article describes a direct detection approach for gene doping that gives a clear yes-or-no answer based on the presence or absence of transgenic DNA in peripheral blood samples. By exploiting a priming strategy to specifically amplify intronless DNA sequences, we developed PCR protocols allowing the detection of very small amounts of transgenic DNA in genomic DNA samples to screen for six prime candidate genes. Our detection strategy was verified in a mouse model, giving positive signals from minute amounts (20 μl) of blood samples for up to 56 days following intramuscular adeno-associated virus-mediated gene transfer, one of the most likely candidate vector systems to be misused for gene doping. To make our detection strategy amenable for routine testing, we implemented a robust sample preparation and processing protocol that allows cost-efficient analysis of small human blood volumes (200 μl) with high specificity and reproducibility. The practicability and reliability of our detection strategy was validated by a screening approach including 327 blood samples taken from professional and recreational athletes under field conditions.

  15. Detection of Leukemia with Blood Samples Using Raman Spectroscopy and Multivariate Analysis

    NASA Astrophysics Data System (ADS)

    Martínez-Espinosa, J. C.; González-Solís, J. L.; Frausto-Reyes, C.; Miranda-Beltrán, M. L.; Soria-Fregoso, C.; Medina-Valtierra, J.

    2009-06-01

    The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. Blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteers. The imprint was put under the microscope and several points were chosen for Raman measurement. All the spectra were collected by a confocal Raman micro-spectroscopy (Renishaw) with a NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) are applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. The preliminary results suggest that Raman Spectroscopy could be a new technique to study the degree of damage to the bone marrow using just blood samples instead of biopsies, treatment very painful for patients.

  16. Sample preparation prior to the LC-MS-based metabolomics/metabonomics of blood-derived samples.

    PubMed

    Gika, Helen; Theodoridis, Georgios

    2011-07-01

    Blood represents a very important biological fluid and has been the target of continuous and extensive research for diagnostic, or health and drug monitoring reasons. Recently, metabonomics/metabolomics have emerged as a new and promising 'omics' platform that shows potential in biomarker discovery, especially in areas such as disease diagnosis, assessment of drug efficacy or toxicity. Blood is collected in various establishments in conditions that are not standardized. Next, the samples are prepared and analyzed using different methodologies or tools. When targeted analysis of key molecules (e.g., a drug or its metabolite[s]) is the aim, enforcement of certain measures or additional analyses may correct and harmonize these discrepancies. In omics fields such as those performed by holistic analytical approaches, no such rules or tools are available. As a result, comparison or correlation of results or data fusion becomes impractical. However, it becomes evident that such obstacles should be overcome in the near future to allow for large-scale studies that involve the assaying of samples from hundreds of individuals. In this case the effect of sample handling and preparation becomes very serious, in order to avoid wasting months of work from experts and expensive instrument time. The present review aims to cover the different methodologies applied to the pretreatment of blood prior to LC-MS metabolomic/metabonomic studies. The article tries to critically compare the methods and highlight issues that need to be addressed.

  17. Children's Emotion Regulation across and within Nations: A Comparison of Ghanaian, Kenyan, and American Youth

    ERIC Educational Resources Information Center

    Morelen, Diana; Zeman, Janice; Perry-Parrish, Carisa; Anderson, Ellen

    2012-01-01

    This research examined national, regional, developmental, and gender differences in children's reported management of anger and sadness. Participants (8-15 years) were 103 Ghanaian children from a village setting, 142 Ghanaian children from a middle-class urban context, 106 Kenyan children from an impoverished urban context, and 170 children from…

  18. Background and Classroom Correlates of Child Achievement, Cognitive, and Behavioural Outcomes in Rural Kenyan Schoolchildren

    ERIC Educational Resources Information Center

    Daley, Tamara C.; Whaley, Shannon E.; Sigman, Marian D.; Guthrie, Donald; Neumann, Charlotte G.; Bwibo, Nimrod

    2005-01-01

    In the current study, background data (sex, age, and SES) and classroom factors were examined as predictors of scholastic achievement and child cognitive and behavioural outcomes in a group of rural Kenyan schoolchildren during their first year of formal schooling. Previous research in this area has provided mixed results regarding the…

  19. Viewing the Kenyan health system through an equity lens: implications for universal coverage

    PubMed Central

    2011-01-01

    Introduction Equity and universal coverage currently dominate policy debates worldwide. Health financing approaches are central to universal coverage. The way funds are collected, pooled, and used to purchase or provide services should be carefully considered to ensure that population needs are addressed under a universal health system. The aim of this paper is to assess the extent to which the Kenyan health financing system meets the key requirements for universal coverage, including income and risk cross-subsidisation. Recommendations on how to address existing equity challenges and progress towards universal coverage are made. Methods An extensive review of published and gray literature was conducted to identify the sources of health care funds in Kenya. Documents were mainly sourced from the Ministry of Medical Services and the Ministry of Public Health and Sanitation. Country level documents were the main sources of data. In cases where data were not available at the country level, they were sought from the World Health Organisation website. Each financing mechanism was analysed in respect to key functions namely, revenue generation, pooling and purchasing. Results The Kenyan health sector relies heavily on out-of-pocket payments. Government funds are mainly allocated through historical incremental approach. The sector is largely underfunded and health care contributions are regressive (i.e. the poor contribute a larger proportion of their income to health care than the rich). Health financing in Kenya is fragmented and there is very limited risk and income cross-subsidisation. The country has made little progress towards achieving international benchmarks including the Abuja target of allocating 15% of government's budget to the health sector. Conclusions The Kenyan health system is highly inequitable and policies aimed at promoting equity and addressing the needs of the poor and vulnerable have not been successful. Some progress has been made towards

  20. Device and method for automated separation of a sample of whole blood into aliquots

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.

    1989-01-01

    A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.

  1. Paper membrane-based SERS platform for the determination of glucose in blood samples.

    PubMed

    Torul, Hilal; Çiftçi, Hakan; Çetin, Demet; Suludere, Zekiye; Boyacı, Ismail Hakkı; Tamer, Uğur

    2015-11-01

    In this report, we present a paper membrane-based surface-enhanced Raman scattering (SERS) platform for the determination of blood glucose level using a nitrocellulose membrane as substrate paper, and the microfluidic channel was simply constructed by wax-printing method. The rod-shaped gold nanorod particles were modified with 4-mercaptophenylboronic acid (4-MBA) and 1-decanethiol (1-DT) molecules and used as embedded SERS probe for paper-based microfluidics. The SERS measurement area was simply constructed by dropping gold nanoparticles on nitrocellulose membrane, and the blood sample was dropped on the membrane hydrophilic channel. While the blood cells and proteins were held on nitrocellulose membrane, glucose molecules were moved through the channel toward the SERS measurement area. Scanning electron microscopy (SEM) was used to confirm the effective separation of blood matrix, and total analysis is completed in 5 min. In SERS measurements, the intensity of the band at 1070 cm(-1) which is attributed to B-OH vibration decreased depending on the rise in glucose concentration in the blood sample. The glucose concentration was found to be 5.43 ± 0.51 mM in the reference blood sample by using a calibration equation, and the certified value for glucose was 6.17 ± 0.11 mM. The recovery of the glucose in the reference blood sample was about 88 %. According to these results, the developed paper-based microfluidic SERS platform has been found to be suitable for use for the detection of glucose in blood samples without any pretreatment procedure. We believe that paper-based microfluidic systems may provide a wide field of usage for paper-based applications.

  2. Material girls and Material love: Consuming femininity and the contradictions of post-girl power among Kenyan schoolgirls

    PubMed Central

    Mojola, Sanyu A.

    2016-01-01

    In this paper, I use qualitative data to explore the practices engaged in by Kenyan schoolgirls to participate in modern consuming womanhood, as well as the contradictory implications of these practices for thinking about globalized mediated femininities and their enactment in resource-poor settings. The paper examines the centrality of consumption to valued modern femininity among young women around the world, as well as the structural reality of gendered access to income. I show how the cooptation of the materiality of romantic love and normative expectations of male provision in romantic relationships bridge the gap between consumption desires and economic realities among Kenyan schoolgirls in both powerful and problematic ways. The paper ends with a reflection of the implications of these findings for post-girl power, the post-feminist age and the re-inscription of patriarchy. PMID:28344428

  3. Antiplasmodial activity of four Kenyan medicinal plants.

    PubMed

    Omulokoli, E; Khan, B; Chhabra, S C

    1997-04-01

    A preliminary antiplasmodial and phytochemical screening of four Kenyan medicinal plants was carried out. The medicinal plants were extracted and tested for in vitro antiplasmodial activity against chloroquine-sensitive (K67) and chloroquine-resistant (ENT36) strains of Plasmodium falciparum. Out of 16 extracts, 12 were active against ENT36 strain while seven were active against K67 strain, that is, IC50 < or = 50 micrograms/ml. The most active extracts on both strains were those of leaves of Phyllanthus reticulatus Poir, and Suregada zanzibariensis Baill. (Euphorbiaceae) with IC50 < or = 10 micrograms/ml. The stembark of Terminalia spinosa Engl. (Combretaceae) and the stems of Dissotis brazzae Cogn. (Melastomataceae) had IC50 < or = 10 micrograms/ml for strains K67 and ENT36, respectively. A preliminary phytochemical analysis of these plants revealed the presence of different classes of primary and secondary metabolites.

  4. The effectiveness of cooling conditions on temperature of canine EDTA whole blood samples

    PubMed Central

    Sun, Xiaocun; Flatland, Bente

    2016-01-01

    Background Preanalytic factors such as time and temperature can have significant effects on laboratory test results. For example, ammonium concentration will increase 31% in blood samples stored at room temperature for 30 min before centrifugation. To reduce preanalytic error, blood samples may be placed in precooled tubes and chilled on ice or in ice water baths; however, the effectiveness of these modalities in cooling blood samples has not been formally evaluated. The purpose of this study was to evaluate the effectiveness of various cooling modalities on reducing temperature of EDTA whole blood samples. Methods Pooled samples of canine EDTA whole blood were divided into two aliquots. Saline was added to one aliquot to produce a packed cell volume (PCV) of 40% and to the second aliquot to produce a PCV of 20% (simulated anemia). Thirty samples from each aliquot were warmed to 37.7 °C and cooled in 2 ml allotments under one of three conditions: in ice, in ice after transfer to a precooled tube, or in an ice water bath. Temperature of each sample was recorded at one minute intervals for 15 min. Results Within treatment conditions, sample PCV had no significant effect on cooling. Cooling in ice water was significantly faster than cooling in ice only or transferring the sample to a precooled tube and cooling it on ice. Mean temperature of samples cooled in ice water was significantly lower at 15 min than mean temperatures of those cooled in ice, whether or not the tube was precooled. By 4 min, samples cooled in an ice water bath had reached mean temperatures less than 4 °C (refrigeration temperature), while samples cooled in other conditions remained above 4.0 °C for at least 11 min. For samples with a PCV of 40%, precooling the tube had no significant effect on rate of cooling on ice. For samples with a PCV of 20%, transfer to a precooled tube resulted in a significantly faster rate of cooling than direct placement of the warmed tube onto ice. Discussion Canine

  5. Blood sampling in juvenile buff-breasted sandpipers: Movement, weight change and survival

    USGS Publications Warehouse

    Lanctot, Richard B.

    1994-01-01

    The effect of blood sampling on juvenile Buff-breasted Sandpipers (Tryngites subruficollis) was evaluated by comparing movements, mass, and survival of 10 broods (37 chicks) that were bled and eight broods (31 chicks) that were not bled. Blood was sampled from the jugular vein of chicks when they weighed 9.1 ± 0.9 g (x̄ ± SD) on or within 1 d of hatch. Chicks showed few short-term negative effects from blood sampling. Individual chicks suffered little physical injury, and five of eight chicks where injury occurred (i.e., hematomas formed) survived to fledging. Furthermore, bled broods gained mass at a comparable rate during the first 5 d post-hatch, and were resighted at similar frequencies as broods that were not bled. Bled broods moved slightly longer distances than control broods 1 d after hatch, however. This increased activity may have been stress-induced, but was only temporary; bled and control broods made similar long-term movements, and the probability of resighting was similar at fledging. With the proper precautions, it appears that Buff-breasted Sandpiper young can be safely sampled for blood at an early age without causing undue harm.

  6. Integrating ICT in Kenyan Secondary Schools: An Exploratory Case Study of a Professional Development Programme

    ERIC Educational Resources Information Center

    Tondeur, Jo; Krug, Don; Bill, Mike; Smulders, Maaike; Zhu, Chang

    2015-01-01

    This study explores the introduction of Information and Communication Technology (ICT) in Kenyan secondary schools. Specifically, it is a case study of four schools with no previous access to ICT. The professional development programme from which data for this study were drawn was designed to support teachers learning to integrate ICT in the…

  7. Dimensions of Kenyan University Academic Staff's Job Satisfaction in View of Various Managerial Leadership Practices

    ERIC Educational Resources Information Center

    Kiplangat, Henry Kiptiony; Momanyi, Marcella; Kangethe, Ngigi Simon

    2017-01-01

    Attaining high levels of academic staff job satisfaction has proved to be challenging for university management. This paper is an excerpt of a study that investigated the magnitude of Kenyan University academic staff's job satisfaction based on various managerial leadership practices. The study focused on the Rift Valley Region (RVR) of Kenya. The…

  8. Heat stabilization of blood spot samples for determination of metabolically unstable drug compounds

    PubMed Central

    Blessborn, Daniel; Sköld, Karl; Zeeberg, David; Kaewkhao, Karnrawee; Sköld, Olof; Ahnoff, Martin

    2014-01-01

    Background Sample stability is critical for accurate analysis of drug compounds in biosamples. The use of additives to eradicate the enzymatic activity causing loss of these analytes has its limitations. Results A novel technique for sample stabilization by rapid, high-temperature heating was used. The stability of six commercial drugs in blood and blood spots was investigated under various conditions with or without heat stabilization at 95°C. Oseltamivir, cefotaxime and ribavirin were successfully stabilized by heating whereas significant losses were seen in unheated samples. Amodiaquine was stable with and without heating. Artemether and dihydroartemisinin were found to be very heat sensitive and began to decompose even at 60°C. Conclusion Heat stabilization is a viable technique to maintain analytes in blood spot samples, without the use of chemical additives, by stopping the enzymatic activity that causes sample degradation. PMID:23256470

  9. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  10. Genetic homogeneity of goat malaria parasites in Asia and Africa suggests their expansion with domestic goat host.

    PubMed

    Kaewthamasorn, Morakot; Takeda, Mika; Saiwichai, Tawee; Gitaka, Jesse N; Tiawsirisup, Sonthaya; Imasato, Yuhei; Mossaad, Ehab; Sarani, Ali; Kaewlamun, Winai; Channumsin, Manun; Chaiworakul, Suchart; Katepongpun, Wichit; Teeveerapunya, Surapong; Panthong, Jarus; Mureithi, Dominic K; Bawm, Saw; Htun, Lat Lat; Win, Mar Mar; Ismail, Ahmed Ali; Ibrahim, Abdalla Mohamed; Suganuma, Keisuke; Hakimi, Hassan; Nakao, Ryo; Katakura, Ken; Asada, Masahito; Kaneko, Osamu

    2018-04-11

    Plasmodium was first identified in a goat in Angola in 1923, and only recently characterized by DNA isolation from a goat blood sample in Zambia. Goats were first domesticated in the Fertile Crescent approximately 10,000 years ago, and are now globally distributed. It is not known if the Plasmodium identified in African goats originated from parasites circulating in the local ungulates, or if it co-evolved in the goat before its domestication. To address this question, we performed PCR-based surveillance using a total of 1,299 goat blood samples collected from Sudan and Kenya in Africa, Iran in west Asia, and Myanmar and Thailand in southeast Asia. Plasmodium DNA was detected from all locations, suggesting that the parasite is not limited to Africa, but widely distributed. Whole mitochondrial DNA sequences revealed that there was only one nucleotide substitution between Zambian/Kenyan samples and others, supporting the existence of a goat-specific Plasmodium species, presumably Plasmodium caprae, rather than infection of goats by local ungulate malaria parasites. We also present the first photographic images of P. caprae, from one Kenyan goat sample.

  11. Frontrunners in ICTL: Kenyan Runners' Improvement in Training, Informal Learning and Economic Opportunities Using Smartphones

    ERIC Educational Resources Information Center

    Hansson, Per Olof; Jobe, William

    2014-01-01

    The primary aim of this research was to study how mobile technology shapes, changes, and develops informal learning outside the classroom and school environment. In this study we provided each of the 30 Kenyan elite runners with a simple Android smartphone and free Internet for one year. This research project was a developmental intervention with…

  12. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    PubMed

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  13. A cell transportation solution that preserves live circulating tumor cells in patient blood samples.

    PubMed

    Stefansson, Steingrimur; Adams, Daniel L; Ershler, William B; Le, Huyen; Ho, David H

    2016-05-06

    Circulating tumor cells (CTCs) are typically collected into CellSave fixative tubes, which kills the cells, but preserves their morphology. Currently, the clinical utility of CTCs is mostly limited to their enumeration. More detailed investigation of CTC biology can be performed on live cells, but obtaining live CTCs is technically challenging, requiring blood collection into biocompatible solutions and rapid isolation which limits transportation options. To overcome the instability of CTCs, we formulated a sugar based cell transportation solution (SBTS) that stabilizes cell viability at ambient temperature. In this study we examined the long term viability of human cancer cell lines, primary cells and CTCs in human blood samples in the SBTS for transportation purposes. Four cell lines, 5 primary human cells and purified human PBMCs were tested to determine the viability of cells stored in the transportation solution at ambient temperature for up to 7 days. We then demonstrated viability of MCF-7 cells spiked into normal blood with SBTS and stored for up to 7 days. A pilot study was then run on blood samples from 3 patients with metastatic malignancies stored with or without SBTS for 6 days. CTCs were then purified by Ficoll separation/microfilter isolation and identified using CTC markers. Cell viability was assessed using trypan blue or CellTracker™ live cell stain. Our results suggest that primary/immortalized cell lines stored in SBTS remain ~90% viable for > 72 h. Further, MCF-7 cells spiked into whole blood remain viable when stored with SBTS for up to 7 days. Finally, live CTCs were isolated from cancer patient blood samples kept in SBTS at ambient temperature for 6 days. No CTCs were isolated from blood samples stored without SBTS. In this proof of principle pilot study we show that viability of cell lines is preserved for days using SBTS. Further, this solution can be used to store patient derived blood samples for eventual isolation of viable CTCs after

  14. Are gait characteristics and ground reaction forces related to energy cost of running in elite Kenyan runners?

    PubMed

    Santos-Concejero, J; Tam, N; Coetzee, D R; Oliván, J; Noakes, T D; Tucker, R

    2017-03-01

    The aim of this study was to determine whether gait cycle characteristics are associated with running economy in elite Kenyan runners. Fifteen elite Kenyan male runners completed two constant-speed running sets on a treadmill (12 km ·h -1 and 20 km ·h -1 ). VO 2 and respiratory exchange ratio values were measured to calculate steady-state oxygen and energy cost of running. Gait cycle characteristics and ground contact forces were measured at each speed. Oxygen cost of running at different velocities was 192.2 ± 14.7 ml· kg -1 · km -1 at 12 km· h -1 and 184.8 ± 9.9 ml· kg -1 · km -1 at 20 km· h -1 , which corresponded to a caloric cost of running of 0.94 ± 0.07 kcal ·kg -1 ·km -1 and 0.93 ± 0.07 kcal· kg -1 · km -1 . We found no significant correlations between oxygen and energy cost of running and biomechanical variables and ground reaction forces at either 12 or 20 km· h -1 . However, ground contact times were ~10.0% shorter (very large effect) than in previously published literature in elite runners at similar speeds, alongside an 8.9% lower oxygen cost (very large effect). These results provide evidence to hypothesise that the short ground contact times may contribute to the exceptional running economy of Kenyan runners.

  15. Kenyan female sex workers' use of female-controlled nonbarrier modern contraception: do they use condoms less consistently?

    PubMed

    Yam, Eileen A; Okal, Jerry; Musyoki, Helgar; Muraguri, Nicholas; Tun, Waimar; Sheehy, Meredith; Geibel, Scott

    2016-03-01

    To examine whether nonbarrier modern contraceptive use is associated with less consistent condom use among Kenyan female sex workers (FSWs). Researchers recruited 579 FSWs using respondent-driven sampling. We conducted multivariate logistic regression to examine the association between consistent condom use and female-controlled nonbarrier modern contraceptive use. A total of 98.8% reported using male condoms in the past month, and 64.6% reported using female-controlled nonbarrier modern contraception. In multivariate analysis, female-controlled nonbarrier modern contraceptive use was not associated with decreased condom use with clients or nonpaying partners. Consistency of condom use is not compromised when FSWs use available female-controlled nonbarrier modern contraception. FSWs should be encouraged to use condoms consistently, whether or not other methods are used simultaneously. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Transformations in Kenyan Science Teachers' Locus of Control: The Influence of Contextualized Science and Emancipated Student Learning

    ERIC Educational Resources Information Center

    Anderson, D.; Nashon, S.; Namazzi, E.; Okemwa, P.; Ombogo, P.; Ooko, S.; Beru, F.

    2015-01-01

    This study investigated Kenyan science teachers' pedagogical transformations, which manifested as they enacted and experienced a reformed contextualized science curriculum in which students' learning experiences were critical catalysts of teacher change. Twelve high school teachers voluntarily participated in the study and were interviewed about…

  17. Utility of blood pressure genetic risk score in admixed Hispanic samples.

    PubMed

    Beecham, A H; Wang, L; Vasudeva, N; Liu, Z; Dong, C; Goldschmidt-Clermont, P J; Pericak-Vance, M A; Rundek, T; Seo, D; Blanton, S H; Sacco, R L; Beecham, G W

    2016-12-01

    Hypertension is strongly influenced by genetic factors. Although hypertension prevalence in some Hispanic sub-populations is greater than in non-Hispanic whites, genetic studies on hypertension have focused primarily on samples of European descent. A recent meta-analysis of 200 000 individuals of European descent identified 29 common genetic variants that influence blood pressure, and a genetic risk score derived from the 29 variants has been proposed. We sought to evaluate the utility of this genetic risk score in Hispanics. The sample set consists of 1994 Hispanics from 2 cohorts: the Northern Manhattan Study (primarily Dominican/Puerto Rican) and the Miami Cardiovascular Registry (primarily Cuban/South American). Risk scores for systolic and diastolic blood pressure were computed as a weighted sum of the risk alleles, with the regression coefficients reported in the European meta-analysis used as weights. Association of risk score with blood pressure was tested within each cohort, adjusting for age, age 2 , sex and body mass index. Results were combined using an inverse-variance meta-analysis. The risk score was significantly associated with blood pressure in our combined sample (P=5.65 × 10 -4 for systolic and P=1.65 × 10 -3 for diastolic) but the magnitude of the effect sizes varied by degree of European, African and Native American admixture. Further studies among other Hispanic sub-populations are needed to elucidate the role of these 29 variants and identify additional genetic and environmental factors contributing to blood pressure variability in Hispanics.

  18. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  19. Turkana Children's Sociocultural Practices of Pastoralist Lifestyles and Science Curriculum and Instruction in Kenyan Early Childhood Education

    ERIC Educational Resources Information Center

    Ng'asike, John Teria

    2010-01-01

    This dissertation discusses the findings of an ethnographic exploratory study of Turkana nomadic pastoralist children's sociocultural practices of their everyday lifestyles and science curriculum and instruction in Kenyan early childhood curriculum. The study uses the findings from Turkana elders to challenge the dominant society in Kenya that…

  20. Analysis of Influence of Sponsorship Career Function of Mentorship on Women's Leadership Advancement in Kenyan Universities

    ERIC Educational Resources Information Center

    Severina, Wambeti Njagi; Edabu, Paul; Kimani, Cecilia

    2016-01-01

    Women working in Kenyan universities should be provided with the many benefits of sponsorship, a mentorship function. Mentors should for example give their mentees challenging assignments which prepare them for top leadership positions. But it is possible that women may not be getting this support from their mentors. Therefore, the researcher did…

  1. Impact of partial pressure of oxygen in blood samples on the performance of systems for self-monitoring of blood glucose.

    PubMed

    Schmid, Christina; Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido

    2014-03-01

    The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between -14.6% and -21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were -0.3% and -0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information.

  2. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    PubMed

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  3. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study

    PubMed Central

    Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.

    2015-01-01

    Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197

  4. Impact of biogas digesters on wood utilisation and self-reported back pain for women living on rural Kenyan smallholder dairy farms.

    PubMed

    Dohoo, Carolyn; VanLeeuwen, John; Read Guernsey, Judith; Critchley, Kim; Gibson, Mark

    2013-01-01

    Women living on rural Kenyan dairy farms spend significant amounts of time collecting wood for cooking. Biogas digesters, which generate biogas for cooking from the anaerobic decomposition of livestock manure, are an alternative fuel source. The objective of this study was to quantify the quality of life and health benefits of installing biogas digesters on rural Kenyan dairy farms with respect to wood utilisation. Women from 62 farms (31 biogas farms and 31 referent farms) participated in interviews to determine reliance on wood and the impact of biogas digesters on this reliance. Self-reported back pain, time spent collecting wood and money spent on wood were significantly lower (p < 0.01) for the biogas group, compared to referent farms. Multivariable linear regression showed that wood consumption increased by 2 lbs/day for each additional family member living on a farm. For an average family of three people, the addition of one cow was associated with increased wood consumption by 1.0 lb/day on biogas farms but by 4.4 lbs/day on referent farms (significant interaction variable - likely due to additional hot water for cleaning milk collection equipment). Biogas digesters represent a potentially important technology that can reduce reliance on wood fuel and improve health for Kenyan dairy farmers.

  5. To mix or not to mix venous blood samples collected in vacuum tubes?

    PubMed

    Parenmark, Anna; Landberg, Eva

    2011-09-08

    There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.

  6. Effects of anesthesia and blood sampling techniques on plasma metabolites and corticosterone in the rat.

    PubMed

    Arnold, Myrtha; Langhans, Wolfgang

    2010-04-19

    Blood is routinely sampled from laboratory animals in biomedical research, and many of the commonly applied sampling techniques require anesthesia. Acute effects of many sampling and anesthesia procedures may confound the results, but those effects are incompletely characterized. We here compare the effects of four common anesthesia procedures (inhalation anesthesia with ether (EA) or isoflurane (IA) and intraperitoneal injection anesthesia with xylazin/ketamine (XKA) or medetomidine/midazolam/fentanyl (MMFA)) on plasma concentrations of glucose, lactate, non-esterified fatty acids (NEFAs), and corticosterone in blood obtained from a previously implanted jugular vein (JV) catheter with the effect of JV blood sampling from non-anesthetized, freely-moving rats (JV-NA). Also, we included in the comparison two other blood sampling procedures usually performed without anesthesia (NA), i.e., puncture of the saphenic vein (SV) and tail incision (TI). Whereas the control procedure (JV-NA) did not significantly affect any of the target parameters, plasma glucose increased from 14 (JV-IA) to 44 (JV-MMFA) % (all Ps=0.05 when compared with the control procedure) in all blood samples collected in anesthesia and was 12 and 14% lower (both Ps<0.05) in SV-NA and TI-NA samples, respectively. Plasma lactate increased from 74 (JV-IA) to 226% (SV-NA) (all Ps<0.05) with all sampling and anesthesia procedures except for JV-XKA and JV-MMF. Plasma NEFAs increased to 52% (P<0.05) with the TI-NA procedure and appeared to decrease with the JV-IA and JV-MMFA procedures (both Ps>0.05). Finally, only the JV-EA and the JV-MMFA procedures increased plasma corticosterone (+525 and +353%, respectively, both Ps< 0.05). The JV-IA and JV-XKA procedures appeared to increase it as well, but these differences did not reach statistical significance. Thus, anesthesia and blood sampling procedures can have profound acute effects on plasma metabolite and hormone concentrations. This must be considered for

  7. Comparison of home fortification with two iron formulations among Kenyan children: Rationale and design of a placebo-controlled non-inferiority trial.

    PubMed

    Teshome, Emily M; Otieno, Walter; Terwel, Sofie R; Osoti, Victor; Demir, Ayşe Y; Andango, Pauline E A; Prentice, Andrew M; Verhoef, Hans

    2017-09-01

    Home fortification powders containing iron and other micronutrients have been recommended by World Health Organisation to prevent iron deficiency anaemia in areas of high prevalence. There is evidence, however, that home fortification at this iron dose may cause gastrointestinal adverse events including diarrhoea. Providing a low dose of highly absorbable iron (3 mg iron as NaFeEDTA) may be safer because the decreased amount of iron in the gut lumen can possibly reduce the burden of these adverse effects whilst resulting in similar or higher amounts of absorbed iron. To show non-inferiority of home fortification with 3 mg iron as NaFeEDTA compared with 12.5 mg iron as encapsulated ferrous fumarate, with haemoglobin response as the primary outcome. 338 Kenyan children aged 12-36 months will be randomly allocated to daily home fortification with either: a) 3 mg iron as NaFeEDTA (experimental treatment), b) 12.5 mg iron as encapsulated ferrous fumarate (reference), or c) placebo. At baseline, after 30 days of intervention and within 100 days post-intervention, blood samples will be assessed for primary outcome (haemoglobin concentration), iron status markers, Plasmodium parasitaemia and inflammation markers. Urine and stool samples will be assessed for hepcidin concentrations and inflammation, respectively. Adherence will be assessed by self-reporting, sachet counts and by an electronic monitoring device. If daily home fortification with a low dose of iron (3 mg NaFeEDTA) has similar or superior efficacy to a high dose (12.5 mg ferrous fumarate) then it would be the preferred choice for treatment of iron deficiency anaemia in children.

  8. Patterns of LH and FSH in men during high-frequency blood sampling.

    PubMed

    Scheele, F; Lambalk, C B; Schoemaker, J; van Kessel, H; de Koning, J; van Dieten, J A; van Rees, G P; de Vries Robles-Korsen, T J

    1987-07-01

    The aim of the study was to test the hypothesis that in serial determinations of concentrations of LH and FSH involving blood samples taken every minute, the observed pulses of LH and FSH which last less than 3-4 min might not be a physiological phenomenon but part of the 'noise' of the radioimmunoassay or blood-sampling technique. Blood was sampled every minute for a period of 90 min in six men. During the first 45 min, blood was sampled by means of vacuum tubes only. During the second 45 min, sampling took place with a syringe via a rubber stopper, either using a tourniquet (n = 3) or flushing the cannula with heparinized saline. Three criteria were used to identify variations in the patterns of LH and FSH as true hormonal changes. First, a threshold was used which had to be exceeded by the difference between nadir and maximum values before a pulse could be identified. An average of approximately six pulses per 90 min was found in both the LH and FSH series. The majority of these pulses lasted less than 3-4 min. In two subjects, larger LH pulses of longer duration were measured. Secondly, differences between duplicate measurements of nadir and/or maximum values of more than one-third of the amplitude of a pulse were considered unacceptable. This involved about 75% of the pulses. Thirdly, the reproducibility of the hormone variations was estimated. In one subject, concentrations of LH were measured four times in four separate assays.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Development of blood extraction system designed by female mosquito's blood sampling mechanism for bio-MEMS

    NASA Astrophysics Data System (ADS)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2005-02-01

    A compact and wearable wristwatch type Bio-MEMS such as a health monitoring system (HMS) to detect blood sugar level for diabetic patient, was newly developed. The HMS consists of (1) a indentation unit with a microneedle to generate the skin penetration force using a shape memory alloy(SMA) actuator, (2) a pumping unit using a bimorph PZT piezoelectric actuator to extract the blood and (3) a gold (Au) electrode as a biosensor immobilized GOx and attached to the gate electrode of MOSFET to detect the amount of Glucose in extracted blood. GOx was immobilized on a self assembled spacer combined with an Au electrode by the cross-link method using BSA as an additional bonding material. The device can extract blood in a few microliter through a painless microneedle with the negative pressure by deflection of the bimorph PZT piezoelectric actuator produced in the blood chamber, by the similar way the female mosquito extracts human blood with muscle motion to flex or relax. The performances of the liquid sampling ability of the pumping unit through a microneedle (3.8mm length, 100μm internal diameter) using the bimorph PZT piezoelectric microactuator were measured. The blood extraction micro device could extract human blood at the speed of 2μl/min, and it is enough volume to measure a glucose level, compared to the amount of commercial based glucose level monitor. The electrode embedded in the blood extraction device chamber could detect electrons generated by the hydrolysis of hydrogen peroxide produced by the reaction between GOx and glucose in a few microliter extracted blood, using the constant electric current measurement system of the MOSFET type hybrid biosensor. The output voltage for the glucose diluted in the chamber was increased lineally with increase of the glucose concentration.

  10. A Quantitative Study of Teacher Readiness to Teach School-Based HIV/AIDS Education in Kenyan Primary Schools

    ERIC Educational Resources Information Center

    Lang'at, Edwin K.

    2014-01-01

    Purpose and Method of Study: The purpose of this study was to investigate teachers' self-perceived readiness to teach school-based HIV/AIDS Awareness and Prevention education in Kenyan primary schools based on their knowledge, attitudes and instructional confidence. This research utilized a non-experimental quantitative approach with a…

  11. Is Work-Family Balance a Possibility? The Case of Kenyan Female Teachers in Urban Public Schools

    ERIC Educational Resources Information Center

    Muasya, Gladys

    2016-01-01

    Young mothers in Kenyan public schools experience a high level of work-family conflict. Currently, there are no formal family-friendly policies, despite declining levels of extended family support and rising cost of hiring domestic workers. A total of 375 female teachers from three towns and Nairobi city filled open-ended surveys to examine the…

  12. Optical detection of Trypanosoma cruzi in blood samples for diagnosis purpose

    NASA Astrophysics Data System (ADS)

    Alanis, Elvio; Romero, Graciela; Alvarez, Liliana; Martinez, Carlos C.; Basombrio, Miguel A.

    2004-10-01

    An optical method for detection of Trypanosoma Cruzi (T. cruzi) parasites in blood samples of mice infected with Chagas disease is presented. The method is intended for use in human blood, for diagnosis purposes. A thin layer of blood infected by T. cruzi parasites, in small concentrations, is examined in an interferometric microscope in which the images of the vision field are taken by a CCD camera and temporarily stored in the memory of a host computer. The whole sample is scanned displacing the microscope plate by means of step motors driven by the computer. Several consecutive images of the same field are taken and digitally processed by means of image temporal differentiation in order to detect if a parasite is eventually present in the field. Each field of view is processed in the same fashion, until the full area of the sample is covered or until a parasite is detected, in which case an acoustical warning is activated and the corresponding image is displayed permitting the technician to corroborate the result visually. A discussion of the reliability of the method as well as a comparison with other well established techniques are presented.

  13. A healthy volunteer study to investigate trace element contamination of blood samples by stainless steel venepuncture needles.

    PubMed

    Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D

    2012-02-01

    The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.

  14. Delay in blood sampling for routine newborn screening is associated with increased risk of schizophrenia.

    PubMed

    Nordentoft, Merete; Larsen, Janne Tidselbak; Pedersen, Carsten Bøcker; Sørensen, Holger Jelling; Hollegaard, Mads Villiam; Hougaard, David Michael; Mortensen, Preben Bo; Petersen, Liselotte

    2015-03-01

    The Danish Neonatal Screening Biobank, containing dried blood spot samples from all newborn in Denmark, is a unique source of data that can be utilized for analyses of genetic and environmental exposures related to schizophrenia and other mental disorders. In previous analyses, we have found that early and late blood sampling, compared to sampling at day 5, was associated with increased risk of schizophrenia. As delay in sampling of blood for neonatal screening cannot in itself influence the risk of schizophrenia, it must be seen as a proxy for unknown underlying causes responsible for this association. Therefore, we investigated whether the increased risk can be explained by other risk factors for schizophrenia. A case-control design was applied. A total of 846 cases with schizophrenia were selected from the Danish Psychiatric Case Register. One control was selected for each case, matched on sex and exact date of birth. Both early and late blood sampling was associated with increased risk for schizophrenia. Compared to blood sampling at day 5, sampling at days 0 to 4 after birth was associated with an incidence rate ratio (IRR) of 1.46 (95% CI 1.15-1.87) for development of schizophrenia, and sampling at days 6 to 9 and at days 10 to 53 was associated with an IRR of 1.5 (95% CI 1.13-1.98) and 3.00 (95% CI 1.59-5.67), respectively. After adjusting the estimates for place of birth, both parents' psychiatric illness, maternal and paternal age, parents' country of origin, child admission, and parental education and income, the estimates were slightly different. Thus, blood collection at 0-4days was associated with an IRR of 1.27 (95% CI 0.94-1.71), 6-9days 1.31 (95% CI 0.94-1.84) and 10+days 3.52 (95% CI 1.50 to 8.24). After adjusting risk estimates for well-known risk factors, delay in sampling of blood for neonatal screening was associated with unexplained increased risk of schizophrenia. Thus, a key finding is that age at test is a proxy for unobserved risk factors

  15. Speech and Language Disorders in Kenyan Children: Adapting Tools For Regions With Few Assessment Resources

    PubMed Central

    Carter, Julie Anne; Murira, Grace; Gona, Joseph; Tumaini, Judy; Lees, Janet; Neville, Brian George; Newton, Charles Richard

    2013-01-01

    This study sought to adapt a battery of Western speech and language assessment tools to a rural Kenyan setting. The tool was developed for children whose first language was KiGiryama, a Bantu language. A total of 539 Kenyan children (males=271, females=268, ethnicity=100% Kigiryama. Data were collected from 303 children admitted to hospital with severe malaria and 206 age-matched children recruited from the village communities. The language assessments were based upon the Content, Form and Use (C/F/U) model. The assessment was based upon the adapted versions of the Peabody Picture Vocabulary Test, Test for the Reception of Grammar, Renfrew Action Picture Test, Pragmatics Profile of Everyday Communication Skills in Children, Test of Word Finding and language specific tests of lexical semantics, higher level language. Preliminary measures of construct validity suggested that the theoretical assumptions behind the construction of the assessments were appropriate and re-test and inter-rater reliability scores were acceptable. These findings illustrate the potential to adapt Western speech and language assessments in other languages and settings, particularly those in which there is a paucity of standardised tools. PMID:24294109

  16. Whole blood flow cytometry measurements of in vivo platelet activation in critically-Ill patients are influenced by variability in blood sampling techniques.

    PubMed

    Rondina, Matthew T; Grissom, Colin K; Men, Shaohua; Harris, Estelle S; Schwertz, Hansjorg; Zimmerman, Guy A; Weyrich, Andrew S

    2012-06-01

    Flow cytometry is often used to measure in vivo platelet activation in critically-ill patients. Variability in blood sampling techniques, which may confound these measurements, remains poorly characterized. Platelet activation was measured by flow cytometry performed on arterial and venous blood from 116 critically-ill patients. We determined how variability in vascular sampling site, processing times, and platelet counts influenced levels of platelet-monocyte aggregates (PMA), PAC-1 binding (for glycoprotein (GP) IIbIIIa), and P-selectin (P-SEL) expression. Levels of PMA, but not PAC-1 binding or P-SEL expression, were significantly affected by variability in vascular sampling site. Average PMA levels were approximately 60% higher in whole blood drawn from an arterial vessel compared to venous blood (16.2±1.8% vs. 10.7±1.2%, p<0.05). Levels of PMA in both arterial and venous blood increased significantly during ex vivo processing delays (1.7% increase for every 10 minute delay, p<0.05). In contrast, PAC-1 binding and P-SEL expression were unaffected by processing delays. Levels of PMA, but not PAC-1 binding or P-SEL expression, were correlated with platelet count quartiles (9.4±1.6% for the lowest quartile versus 15.4±1.6% for the highest quartile, p<0.05). In critically-ill patients, variability in vascular sampling site, processing times, and platelet counts influence levels of PMA, but not PAC-1 binding or P-SEL expression. These data demonstrate the need for rigorous adherence to blood sampling protocols, particularly when levels of PMA, which are most sensitive to variations in blood collection, are measured for detection of in vivo platelet activation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. The Discourse of Whole Class Teaching: A Comparative Study of Kenyan and Nigerian Primary English Lessons

    ERIC Educational Resources Information Center

    Abd-Kadir, Jan; Hardman, Frank

    2007-01-01

    This paper explores the discourse of whole class teaching in Kenyan and Nigerian primary school English lessons. Twenty lessons were analysed using a system of discourse analysis focusing on the teacher-led three-part exchange sequence of Initiation-Response-Feedback (IRF). The focus of the analysis was on the first and third part of the IRF…

  18. Can Vocational Programmes Change Use and Exchange Value Attributions of School Leavers: A Kenyan Case Study?

    ERIC Educational Resources Information Center

    Saunders, Murray; Sambili, Helen

    1995-01-01

    A survey of Kenyan school leavers (200 responses) and 34 interviews show that the exchange value of school-leaving exams is predominant and the use value of vocational programs has little impact. Apparently, 80% of school effort has actual exchange value for only 20% of school leavers, whereas 20% of effort directed at self-employment has…

  19. Raman Spectroscopy: A New Proposal for the Detection of Leukemia Using Blood Samples

    NASA Astrophysics Data System (ADS)

    Martínez-Espinosa, J. C.; González-Solís, J. L.; Frausto-Reyes, C.; Miranda-Beltrán, M. L.; Soria-Fregoso, C.; Medina-Valtierra, J.; Sánchez-Gómez, R.

    2008-08-01

    The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. The blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteer. The imprint was put under the microscope and several points were chosen for Raman measurement. All spectra were collected at confocal Raman micro-spectroscopy (Renishaw) with NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) is applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. In addition, currently the degree of damage to the bone marrow is estimated through biopsies and therefore it is a very procedure painful. The preliminary results suggest that Raman spectroscopy could be a new technique to study the bone marrow using just blood samples.

  20. New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis.

    PubMed

    Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien

    2015-02-17

    Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.

  1. Venous blood provides lower GLP-1 concentrations than arterialised blood in the postprandial, but not fasted state: Consequences of sampling methods.

    PubMed

    Chen, Yung-Chih; Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Walhin, Jean-Philippe; Betts, James A; Thompson, Dylan; Gonzalez, Javier T

    2018-06-27

    What is the central question of this study? Glucagon-like peptide-1 (GLP-1) is an important obesity/diabetes target, with effects dependent on circulating GLP-1 concentrations. Peripheral tissues extract GLP-1, therefore sampling venous versus arterialised blood may provide different GLP-1 concentrations. This study examined whether arterialisation alters GLP-1 concentrations during fasting and feeding. What is the main finding and its importance? This study demonstrates that venous blood provides lower postprandial, but not fasting, GLP-1 concentrations versus arterialised blood. Therefore, when accurate assessment of postprandial peripheral availability of GLP-1 is required, blood sampling methods should be carefully considered, clearly reported, and arterialisation is recommended. Glucagon-like peptide-1 (GLP-1) displays concentration-dependent effects on metabolism, appetite and angiogenesis, so accurate determination of circulating GLP-1 concentrations is important. This study compared GLP-1 concentrations in venous versus arterialised blood under both fasted and fed conditions. Venous and arterialised blood samples were simultaneously drawn from ten, young, healthy men before, and 30, 60 and 120 min after, ingestion of 75 g glucose. Plasma GLP-1 concentrations increased in response to glucose ingestion (time effect: p < 0.01) and to a lesser extend in venous versus arterialised plasma (time x arterialisation interaction: p < 0.01). Accordingly, the plasma incremental area under the curve was lower in venous versus arterialised plasma (974 ± 88 versus 1214 ± 115 pmol·L x 120 min -1 , respectively, p = 0.049). In the postprandial state, there was a positive relationship between arterialised GLP-1 concentrations and the venous-arterialised difference in GLP-1 concentrations (r 2  = 0.51; p < 0.01). Both arterialised and venous peak GLP-1 concentrations showed positive relationships with peak arterialised insulin concentrations (both r 2

  2. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia. PMID:26524965

  3. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.

  4. Sternal foramina and variant xiphoid morphology in a Kenyan population.

    PubMed

    El-Busaid, H; Kaisha, W; Hassanali, J; Hassan, S; Ogeng'o, J; Mandela, P

    2012-02-01

    Sternal foramina may pose a great hazard during sternal puncture, due to inadvertent cardiac or great vessel injury. They can also be misinterpreted as osteolytic lesions in cross-sectional imaging of the sternum. On the other hand, variant xiphoid morphology such as bifid, duplicated, or trifurcated may be mistaken for fractures during imaging. The distribution of these anomalies differs between populations, but data from Africans is scarcely reported. This study therefore aimed to investigate the distribution and frequency of sternal foramina and variant xiphoid morphology in a Kenyan population. Eighty formalin-fixed adult sterna (42 males [M], 38 females [F]) of age range 18-45 years were studied during dissection at the Department of Human Anatomy, University of Nairobi. Soft tissues were removed from the macerated sterna by blunt dissection and foramina recorded in the manubrium, body, and xiphoid process. The xiphisternal ending was classified as single, bifurcated (2 xiphoid processes with a common stem), or duplicated (2 xiphoid processes with separate stems). Results were analysed using SPSS version 17.0. Foramina were present in 11 specimens (13.8%): 7 M, 4 F. The highest frequency was in the sternal body (n = 9), where they predominantly occurred at the 5th intercostal segment. Xiphoid foramina were present in 2 specimens (both males) (2.5%), while manubrial foramen was not encountered. The xiphisternum ended as a single process in 64 cases (34 M, 30 F) (80%). It bifurcated in 10 cases (5 M, 5 F) (12.5%), and duplicated in 6 cases (4 M, 2 F) (7.5%). There were no cases of trifurcation. Sternal foramina in Kenyans vary in distribution and show higher frequency than in other populations. These variations may complicate sternal puncture, and due caution is recommended. The variant xiphisternal morphology may raise alarm for xiphoid fractures and may therefore be considered a differential.

  5. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer

    PubMed Central

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-01-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments. PMID:25332733

  6. Toxicological investigation in blood samples from suspected impaired driving cases in the Milan area: Possible loss of evidence due to late blood sampling.

    PubMed

    Ferrari, Davide; Manca, Monica; Premaschi, Simone; Banfi, Giuseppe; Locatelli, Massimo

    2018-05-01

    Driving under the influence of illicit drugs (DUID) represents a significant menace to public safety and is therefore sanctioned with severe fines and penalties such as driving disqualification or even arrest in case the accident has caused serious injury or death. In Italy, DUID is regulated by the article 187 of the National Street Code, however, the list of the substances to be searched and their threshold concentrations are left to the 20 Italian regional authorities. A further lack of legislative standardization concerns the type of detection methods and moreover the time gap between the car accident and blood sampling. This interval can be as high as 5h, enough to significantly reduce the concentration of drugs with fast pharmacokinetic. By analyzing 1258 blood tests performed on drivers involved in road traffic crashes in the Milan area between 2012 and 2016 we show that approximately 75% of such drivers who tested positive for THC and 15% of the drivers who tested positive for cocaine are at risk of misjudgment. Considering the severe sanctions associated with DUID, we emphasize the urgency of introducing a corrective factor that takes into account the time elapsed between the accident and blood sampling in order to avoid unfair treatment, including the unjust application of sanctions. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Efficacy of the FilmArray blood culture identification panel for direct molecular diagnosis of infectious diseases from samples other than blood.

    PubMed

    Micó, Miquel; Navarro, Ferran; de Miniac, Daniela; González, Yésica; Brell, Albert; López, Cristina; Sánchez-Reus, Ferran; Mirelis, Beatriz; Coll, Pere

    2015-12-01

    Molecular-based techniques reduce the delay in diagnosing infectious diseases and therefore contribute to better patient outcomes. We assessed the FilmArray blood culture identification (BCID) panel (Biofire Diagnostics/bioMérieux) directly on clinical specimens other than blood: cerebrospinal, joint, pleural and ascitic fluids, bronchoscopy samples and abscesses. We compared the results from 88 samples obtained by culture-based techniques. The percentage of agreement between the two methods was 75 % with a Cohen κ value of 0.51. Global sensitivity and specificity using the FilmArray BCID panel were 71 and 97 %, respectively. Sensitivity was poorer in samples with a low bacterial load, such as ascitic and pleural fluids (25 %), whereas the sensitivity for abscess samples was high (89 %). These findings suggest that the FilmArray BCID panel could be useful to perform microbiological diagnosis directly from samples other than positive blood cultures, as it offers acceptable sensitivity and moderate agreement with conventional microbiological methods. Nevertheless, cost-benefit studies should be performed before introducing this method into algorithms for microbiological diagnostics.

  8. Impact of Use of Smaller Volume, Smaller Vacuum Blood Collection Tubes on Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Berriochoa, Jacob P; Schold, Jesse D; Hustey, Fredric M; Chamberlin, Janelle; Kovach, Annmarie

    2017-10-01

    Hemolyzed blood samples commonly occur in hospital emergency departments (EDs). Our objective was to determine whether replacing standard large-volume/high-vacuum sample tubes with low-volume/low-vacuum tubes would significantly affect ED hemolysis. This was a prospective intervention of the use of small-volume/vacuum collection tubes. We evaluated all potassium samples in ED patients and associated hemolysis. We used χ2 tests to compare hemolysis incidence prior to and following utilization of small tubes for chemistry collection. There were 35,481 blood samples collected during the study period. Following implementation of small-volume tubes, overall hemolysis decreased from a baseline of 11.8% to 2.9% (P < .001) with corresponding reductions in hemolysis with comment (8.95% vs 1.99%; P < .001) gross hemolysis (2.84% vs 0.90%; P < .007). This work demonstrates that significant improvements in ED hemolysis can be achieved by utilization of small-volume/vacuum sample collection tubes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Improved removal of blood contamination from ThinPrep cervical cytology samples for Raman spectroscopic analysis.

    PubMed

    Traynor, Damien; Duraipandian, Shiyamala; Martin, Cara M; O'Leary, John J; Lyng, Fiona M

    2018-05-01

    There is an unmet need for methods to help in the early detection of cervical precancer. Optical spectroscopy-based techniques, such as Raman spectroscopy, have shown great potential for diagnosis of different cancers, including cervical cancer. However, relatively few studies have been carried out on liquid-based cytology (LBC) pap test specimens and confounding factors, such as blood contamination, have been identified. Previous work reported a method to remove blood contamination before Raman spectroscopy by pretreatment of the slides with hydrogen peroxide. The aim of the present study was to extend this work to excessively bloody samples to see if these could be rendered suitable for Raman spectroscopy. LBC ThinPrep specimens were treated by adding hydrogen peroxide directly to the vial before slide preparation. Good quality Raman spectra were recorded from negative and high grade (HG) cytology samples with no blood contamination and with heavy blood contamination. Good classification between negative and HG cytology could be achieved for samples with no blood contamination (sensitivity 92%, specificity 93%) and heavy blood contamination (sensitivity 89%, specificity 88%) with poorer classification when samples were combined (sensitivity 82%, specificity 87%). This study demonstrates for the first time the improved potential of Raman spectroscopy for analysis of ThinPrep specimens regardless of blood contamination. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  10. Blood transfusion sampling and a greater role for error recovery.

    PubMed

    Oldham, Jane

    Patient identification errors in pre-transfusion blood sampling ('wrong blood in tube') are a persistent area of risk. These errors can potentially result in life-threatening complications. Current measures to address root causes of incidents and near misses have not resolved this problem and there is a need to look afresh at this issue. PROJECT PURPOSE: This narrative review of the literature is part of a wider system-improvement project designed to explore and seek a better understanding of the factors that contribute to transfusion sampling error as a prerequisite to examining current and potential approaches to error reduction. A broad search of the literature was undertaken to identify themes relating to this phenomenon. KEY DISCOVERIES: Two key themes emerged from the literature. Firstly, despite multi-faceted causes of error, the consistent element is the ever-present potential for human error. Secondly, current focus on error prevention could potentially be augmented with greater attention to error recovery. Exploring ways in which clinical staff taking samples might learn how to better identify their own errors is proposed to add to current safety initiatives.

  11. Impact of Partial Pressure of Oxygen in Blood Samples on the Performance of Systems for Self-Monitoring of Blood Glucose

    PubMed Central

    Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido

    2014-01-01

    Abstract Background: The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Materials and Methods: Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. Results: The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between −14.6% and −21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were −0.3% and −0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. Conclusions: The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information. PMID:24205977

  12. Vaccination and blood sampling acceptability during Ramadan fasting month: A cross-sectional study in Conakry, Guinea.

    PubMed

    Peiffer-Smadja, Nathan; Ouedraogo, Ramatou; D'Ortenzio, Eric; Cissé, Papa Ndiaga; Zeggani, Zahra; Beavogui, Abdoul Habib; Faye, Sylvain Landry; Le Marcis, Frédéric; Yazdanpanah, Yazdan; Nguyen, Vinh-Kim

    2017-05-02

    There are few data on the acceptability of vaccination or blood sampling during Ramadan fasting month in Muslim countries. This could impact vaccination campaigns, clinical trials or healthcare during Ramadan. Using a semi-structured questionnaire, we conducted a cross-sectional study on 201 practising Muslims and 10 religious leaders in Conakry, Guinea in the wake of the recent epidemic Ebola epidemic. Acceptability of vaccination and blood sampling during Ramadan were investigated as well as reasons for refusal. Vaccination was judged acceptable during Ramadan by 46% (93/201, 95% CI 0.40-0.53) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.11). Blood sampling was judged acceptable during Ramadan by 54% (108/201, 95% CI 0.47-0.60) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.19). The percentage of participants that judged both blood sampling and vaccination acceptable during Ramadan was 40% (81/201, 95% CI 0.34-0.47) for practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) for religious leaders (p=0.048). The most common reasons for refusal of vaccination or blood sampling were that nothing should enter or leave the body during Ramadan (43%), that adverse events could lead to breaking the fast (32%), that blood should not be seen during Ramadan (9%) and that the Quran explicitly forbids it (9%). Although most Muslims leaders and scientists consider that injections including immunization and blood sampling should be authorized during Ramadan, many Muslims in our study judged vaccination or blood sampling unacceptable when fasting. Widely available recommendations on healthcare during Ramadan would be useful to inform Muslims. Copyright © 2017. Published by Elsevier Ltd.

  13. The cost of uncomplicated childhood fevers to Kenyan households: implications for reaching international access targets

    PubMed Central

    Larson, Bruce A; Amin, Abdinasir A; Noor, Abdisalan M; Zurovac, Dejan; Snow, Robert W

    2006-01-01

    Background Fever is the clinical hallmark of malaria disease. The Roll Back Malaria (RBM) movement promotes prompt, effective treatment of childhood fevers as a key component to achieving its optimistic mortality reduction goals by 2010. A neglected concern is how communities will access these new medicines promptly and the costs to poor households when they are located in rural areas distant to health services. Methods We assemble data developed between 2001 and 2002 in Kenya to describe treatment choices made by rural households to treat a child's fever and the related costs to households. Using a cost-of-illness approach, we estimate the expected cost of a childhood fever to Kenyan households in 2002. We develop two scenarios to explore how expected costs to households would change if more children were treated at a health care facility with an effective antimalarial within 48 hours of fever onset. Results 30% of uncomplicated fevers were managed at home with modern medicines, 38% were taken to a health care facility (HCF), and 32% were managed at home without the use of modern medicines. Direct household cash expenditures were estimated at $0.44 per fever, while the total expected cost to households (cash and time) of an uncomplicated childhood fever is estimated to be $1.91. An estimated mean of 1.42 days of caretaker time devoted to each fever accounts for the majority of household costs of managing fevers. The aggregate cost to Kenyan households of managing uncomplicated childhood fevers was at least $96 million in 2002, equivalent to 1.00% of the Kenyan GDP. Fewer than 8% of all fevers were treated with an antimalarial drug within 24 hours of fever onset, while 17.5% were treated within 48 hours at a HCF. To achieve an increase from 17.5% to 33% of fevers treated with an antimalarial drug within 48 hours at a HCF (Scenario 1), children already being taken to a HCF would need to be taken earlier. Under this scenario, direct cash expenditures would not change

  14. The cost of uncomplicated childhood fevers to Kenyan households: implications for reaching international access targets.

    PubMed

    Larson, Bruce A; Amin, Abdinasir A; Noor, Abdisalan M; Zurovac, Dejan; Snow, Robert W

    2006-12-29

    Fever is the clinical hallmark of malaria disease. The Roll Back Malaria (RBM) movement promotes prompt, effective treatment of childhood fevers as a key component to achieving its optimistic mortality reduction goals by 2010. A neglected concern is how communities will access these new medicines promptly and the costs to poor households when they are located in rural areas distant to health services. We assemble data developed between 2001 and 2002 in Kenya to describe treatment choices made by rural households to treat a child's fever and the related costs to households. Using a cost-of-illness approach, we estimate the expected cost of a childhood fever to Kenyan households in 2002. We develop two scenarios to explore how expected costs to households would change if more children were treated at a health care facility with an effective antimalarial within 48 hours of fever onset. 30% of uncomplicated fevers were managed at home with modern medicines, 38% were taken to a health care facility (HCF), and 32% were managed at home without the use of modern medicines. Direct household cash expenditures were estimated at $0.44 per fever, while the total expected cost to households (cash and time) of an uncomplicated childhood fever is estimated to be $1.91. An estimated mean of 1.42 days of caretaker time devoted to each fever accounts for the majority of household costs of managing fevers. The aggregate cost to Kenyan households of managing uncomplicated childhood fevers was at least $96 million in 2002, equivalent to 1.00% of the Kenyan GDP. Fewer than 8% of all fevers were treated with an antimalarial drug within 24 hours of fever onset, while 17.5% were treated within 48 hours at a HCF. To achieve an increase from 17.5% to 33% of fevers treated with an antimalarial drug within 48 hours at a HCF (Scenario 1), children already being taken to a HCF would need to be taken earlier. Under this scenario, direct cash expenditures would not change, and total household costs

  15. Detection of Theileria annulata in blood samples of carrier cattle by PCR.

    PubMed Central

    d'Oliveira, C; van der Weide, M; Habela, M A; Jacquiet, P; Jongejan, F

    1995-01-01

    We report the detection of Theileria annulata, the causative agent of tropical theileriosis, by PCR in blood samples obtained from carrier cattle. The assay employs primers specific for the gene encoding the 30-kDa major merozoite surface antigen of T. annulata. A 721-bp fragment was amplified from blood samples taken monthly from calves experimentally infected with one of four different stocks of T. annulata originating in either Mauritania, Portugal, Spain, or Turkey. At the end of the experiment, five animals carried the infection for 12 months and two animals remained infected for 15 months. DNAs from six other Theileria species, T. parva, T. mutans, T. sergenti, T. buffeli, T. velifera, and T. taurotragi, were not amplified. Moreover, DNAs from four other hemoparasites (Anaplasma centrale, Anaplasma marginale, Babesia bovis, and Babesia bigemina) were also not amplified. As a control, primers derived from the small subunit rRNA gene of Theileria spp. amplified a 1.1-kb DNA fragment from all Theileria species examined but not from the other four hemoparasites. As few as two to three parasites per microliter of infected blood in a 50-microliters sample volume were detected by Southern or microplate hybridization with a T. annulata-specific cDNA probe. In addition, 92 field samples obtained from cattle in Spain were tested; 22% were positive in blood smears, 40% were positive by immunofluorescent antibody test, and 75% were positive for T. annulata by PCR. The method provides a useful diagnostic tool for detecting T. annulata carrier cattle. PMID:8567902

  16. Proposing an Empirically Justified Reference Threshold for Blood Culture Sampling Rates in Intensive Care Units

    PubMed Central

    Castell, Stefanie; Schwab, Frank; Geffers, Christine; Bongartz, Hannah; Brunkhorst, Frank M.; Gastmeier, Petra; Mikolajczyk, Rafael T.

    2014-01-01

    Early and appropriate blood culture sampling is recommended as a standard of care for patients with suspected bloodstream infections (BSI) but is rarely taken into account when quality indicators for BSI are evaluated. To date, sampling of about 100 to 200 blood culture sets per 1,000 patient-days is recommended as the target range for blood culture rates. However, the empirical basis of this recommendation is not clear. The aim of the current study was to analyze the association between blood culture rates and observed BSI rates and to derive a reference threshold for blood culture rates in intensive care units (ICUs). This study is based on data from 223 ICUs taking part in the German hospital infection surveillance system. We applied locally weighted regression and segmented Poisson regression to assess the association between blood culture rates and BSI rates. Below 80 to 90 blood culture sets per 1,000 patient-days, observed BSI rates increased with increasing blood culture rates, while there was no further increase above this threshold. Segmented Poisson regression located the threshold at 87 (95% confidence interval, 54 to 120) blood culture sets per 1,000 patient-days. Only one-third of the investigated ICUs displayed blood culture rates above this threshold. We provided empirical justification for a blood culture target threshold in ICUs. In the majority of the studied ICUs, blood culture sampling rates were below this threshold. This suggests that a substantial fraction of BSI cases might remain undetected; reporting observed BSI rates as a quality indicator without sufficiently high blood culture rates might be misleading. PMID:25520442

  17. Evaluation of PCR Approaches for Detection of Bartonella bacilliformis in Blood Samples.

    PubMed

    Gomes, Cláudia; Martinez-Puchol, Sandra; Pons, Maria J; Bazán, Jorge; Tinco, Carmen; del Valle, Juana; Ruiz, Joaquim

    2016-03-01

    The lack of an effective diagnostic tool for Carrion's disease leads to misdiagnosis, wrong treatments and perpetuation of asymptomatic carriers living in endemic areas. Conventional PCR approaches have been reported as a diagnostic technique. However, the detection limit of these techniques is not clear as well as if its usefulness in low bacteriemia cases. The aim of this study was to evaluate the detection limit of 3 PCR approaches. We determined the detection limit of 3 different PCR approaches: Bartonella-specific 16S rRNA, fla and its genes. We also evaluated the viability of dry blood spots to be used as a sample transport system. Our results show that 16S rRNA PCR is the approach with a lowest detection limit, 5 CFU/μL, and thus, the best diagnostic PCR tool studied. Dry blood spots diminish the sensitivity of the assay. From the tested PCRs, the 16S rRNA PCR-approach is the best to be used in the direct blood detection of acute cases of Carrion's disease. However its use in samples from dry blood spots results in easier management of transport samples in rural areas, a slight decrease in the sensitivity was observed. The usefulness to detect by PCR the presence of low-bacteriemic or asymptomatic carriers is doubtful, showing the need to search for new more sensible techniques.

  18. Detection of Merkel Cell Polyomavirus DNA in Serum Samples of Healthy Blood Donors

    PubMed Central

    Mazzoni, Elisa; Rotondo, John C.; Marracino, Luisa; Selvatici, Rita; Bononi, Ilaria; Torreggiani, Elena; Touzé, Antoine; Martini, Fernanda; Tognon, Mauro G.

    2017-01-01

    Merkel cell polyomavirus (MCPyV) has been detected in 80% of Merkel cell carcinomas (MCC). In the host, the MCPyV reservoir remains elusive. MCPyV DNA sequences were revealed in blood donor buffy coats. In this study, MCPyV DNA sequences were investigated in the sera (n = 190) of healthy blood donors. Two MCPyV DNA sequences, coding for the viral oncoprotein large T antigen (LT), were investigated using polymerase chain reaction (PCR) methods and DNA sequencing. Circulating MCPyV sequences were detected in sera with a prevalence of 2.6% (5/190), at low-DNA viral load, which is in the range of 1–4 and 1–5 copies/μl by real-time PCR and droplet digital PCR, respectively. DNA sequencing carried out in the five MCPyV-positive samples indicated that the two MCPyV LT sequences which were analyzed belong to the MKL-1 strain. Circulating MCPyV LT sequences are present in blood donor sera. MCPyV-positive samples from blood donors could represent a potential vehicle for MCPyV infection in receivers, whereas an increase in viral load may occur with multiple blood transfusions. In certain patient conditions, such as immune-depression/suppression, additional disease or old age, transfusion of MCPyV-positive samples could be an additional risk factor for MCC onset. PMID:29238698

  19. The impact of onset controllability on stigmatization and supportive communication goals toward persons with HIV versus lung cancer: a comparison between Kenyan and U.S. participants.

    PubMed

    Miller, Ann Neville; Fellows, Kelli L; Kizito, Mary N

    2007-01-01

    This study examined the impact of controllability of onset (i.e., means of transmission), disease type (HIV and lung cancer), and culture (Kenya and U.S.) on stigmatizing attitudes and goals for supportive communication. Four hundred sixty-four Kenyan students and 526 American students, and 441 Kenyan nonstudents and 591 American nonstudents were randomly assigned to 1 of 12 hypothetical scenario conditions and asked to respond to questions regarding 3 different types of stigmatizing attitudes and 6 types of supportive communication goals with respect to the character in the scenario. Means of transmission had a strong effect on the blame component of stigma, but none on cognitive attitudes and social interaction components. Similarly, although an effect for means of transmission emerged on intention to provide "recognize own responsibility" and "see others' blame" types of support, no effect was evident for most other supportive interaction goals. Although effects for culture were small, Kenyan participants, student and nonstudent alike, were not as quick as American participants to adopt goals of communicating blame in any direction. Implications for measurement of stigma in future research are discussed.

  20. Transcutaneous bilirubinometry reduces the need for blood sampling in neonates with visible jaundice.

    PubMed

    Mishra, S; Chawla, D; Agarwal, R; Deorari, A K; Paul, V K; Bhutani, V K

    2009-12-01

    We determined usefulness of transcutaneous bilirubinometry to decrease the need for blood sampling to assay serum total bilirubin (STB) in the management of jaundiced healthy Indian neonates. Newborns, > or =35 weeks' gestation, with clinical evidence of jaundice were enrolled in an institutional approved randomized clinical trial. The severity of hyperbilirubinaemia was determined by two non-invasive methods: i) protocol-based visual assessment of bilirubin (VaB) and ii) transcutaneous bilirubin (TcB) determination (BiliCheck). By a random allocation, either method was used to decide the need for blood sampling, which was defined to be present if assessed STB by allocated method exceeded 80% of hour-specific threshold values for phototherapy (2004 AAP Guidelines). A total of 617 neonates were randomized to either TcB (n = 314) or VaB (n = 303) groups with comparable gestation, birth weight and postnatal age. Need for blood sampling to assay STB was 34% lower (95% CI: 10% to 51%) in the TcB group compared with VaB group (17.5% vs 26.4% assessments; risk difference: -8.9%, 95% CI: -2.4% to -15.4%; p = 0.008). Routine use of transcutaneous bilirubinometry compared with systematic visual assessment of bilirubin significantly reduced the need for blood sampling to assay STB in jaundiced term and late-preterm neonates. (ClinicalTrials.gov number, NCT00653874).

  1. Towards Improvement of Student Learning Outcomes: An Assessment of the Professional Development Needs of Lecturers at Kenyan Universities

    ERIC Educational Resources Information Center

    NaliakaMukhale, Phoebe; Hong, Zhu

    2017-01-01

    The aim of this study was to explore the professional development needs of lecturers at Kenyan universities. Specifically, the study investigated the challenges that lecturers and their learners face while in class. It also explored the professional development needs of the lecturers, preferred modes of delivery of the professional development…

  2. Estimating the proportion of pneumonia attributable to pneumococcus in Kenyan adults: latent class analysis.

    PubMed

    Jokinen, Jukka; Scott, J Anthony G

    2010-09-01

    Community-acquired pneumonia is a common cause of hospitalization among African adults, and Streptococcus pneumoniae is assumed to be a frequent cause. Pneumococcal conjugate vaccine is currently being introduced into childhood immunization programs in Africa. The case for adult vaccination is dependent on the contribution of the pneumococcus to the hospital pneumonia burden. Pneumococcal diagnosis is complex because there is no gold standard, and culture methods are invalidated by antibiotic use. We used latent class analysis to estimate the proportion of pneumonia episodes caused by pneumococcus. Furthermore, we extended this methodology to evaluate the effect of antimicrobial treatment on test accuracies and the prevalence of the disease. The study combined data from 5 validation studies of pneumococcal diagnostic tests performed on 281 Kenyan adults with pneumonia. The proportion of pneumonia episodes attributable to pneumococcus was 0.46 (95% confidence interval = 0.36-0.57). Failure to account for the effect of antimicrobial exposure underestimates this proportion as 0.32. A history of antibiotic exposure was a poor predictor of antimicrobial activity in patients' urine. Blood culture sensitivity for pneumococcus was estimated at 0.24 among patients with antibiotic exposure, and 0.75 among those without. The large contribution of pneumococcus to adult pneumonia provides a strong case for the investigation of pneumococcal vaccines in African adults.

  3. A nonlethal sampling method to obtain, generate and assemble whole blood transcriptomes from small, wild mammals.

    PubMed

    Huang, Zixia; Gallot, Aurore; Lao, Nga T; Puechmaille, Sébastien J; Foley, Nicole M; Jebb, David; Bekaert, Michaël; Teeling, Emma C

    2016-01-01

    The acquisition of tissue samples from wild populations is a constant challenge in conservation biology, especially for endangered species and protected species where nonlethal sampling is the only option. Whole blood has been suggested as a nonlethal sample type that contains a high percentage of bodywide and genomewide transcripts and therefore can be used to assess the transcriptional status of an individual, and to infer a high percentage of the genome. However, only limited quantities of blood can be nonlethally sampled from small species and it is not known if enough genetic material is contained in only a few drops of blood, which represents the upper limit of sample collection for some small species. In this study, we developed a nonlethal sampling method, the laboratory protocols and a bioinformatic pipeline to sequence and assemble the whole blood transcriptome, using Illumina RNA-Seq, from wild greater mouse-eared bats (Myotis myotis). For optimal results, both ribosomal and globin RNAs must be removed before library construction. Treatment of DNase is recommended but not required enabling the use of smaller amounts of starting RNA. A large proportion of protein-coding genes (61%) in the genome were expressed in the blood transcriptome, comparable to brain (65%), kidney (63%) and liver (58%) transcriptomes, and up to 99% of the mitogenome (excluding D-loop) was recovered in the RNA-Seq data. In conclusion, this nonlethal blood sampling method provides an opportunity for a genomewide transcriptomic study of small, endangered or critically protected species, without sacrificing any individuals. © 2015 John Wiley & Sons Ltd.

  4. Sex identification of polar bears from blood and tissue samples

    USGS Publications Warehouse

    Amstrup, Steven C.; Garner, G.W.; Cronin, M.A.; Patton, J.C.

    1993-01-01

    Polar bears (Ursus maritimus) can be adversely affected by hunting and other human perturbations because of low population densities and low reproduction rates. The sustainable take of adult females may be as low as 1.5% of the population. Females and accompanying young are most vulnerable to hunting, and hunters have not consistently reported the sex composition of the harvest, therefore a method to confirm the sexes of polar bears harvested in Alaska is needed. Evidence of the sex of harvested animals is often not available, but blood or other tissue samples often are. We extracted DNA from tissue and blood samples, and amplified segments of zinc finger (ZFX and ZFY) genes from both X and Y chromosomes with the polymerase chain reaction. Digestion of amplified portions of the X chromosome with the restriction enzyme HaeIII resulted in subdivision of the original amplified segment into four smaller fragments. Digestion with HaeIII did not subdivide the original segment amplified from the Y chromosome. The differing fragment sizes produced patterns in gel electrophoresis that distinguished samples from male and female bears 100% of the time. This technique is applicable to the investigation of many wildlife management and research questions.

  5. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  6. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  7. Dengue and yellow fever virus vectors: seasonal abundance, diversity and resting preferences in three Kenyan cities.

    PubMed

    Agha, Sheila B; Tchouassi, David P; Bastos, Armanda D S; Sang, Rosemary

    2017-12-29

    The transmission patterns of dengue (DENV) and yellow fever (YFV) viruses, especially in urban settings, are influenced by Aedes (Stegomyia) mosquito abundance and behavior. Despite recurrent dengue outbreaks on the Kenyan coast, these parameters remain poorly defined in this and other areas of contrasting dengue endemicity in Kenya. In assessing the transmission risk of DENV/YFV in three Kenyan cities, we determined adult abundance and resting habits of potential Aedes (Stegomyia) vectors in Kilifi (dengue-outbreak prone), and Nairobi and Kisumu (no dengue outbreaks reported). In addition, mosquito diversity, an important consideration for changing mosquito-borne disease dynamics, was compared. Between October 2014 and June 2016, host-seeking adult mosquitoes were sampled using CO 2 -baited BG-Sentinel traps (12 traps daily) placed in vegetation around homesteads, across study sites in the three major cities. Also, indoor and outdoor resting mosquitoes were sampled using Prokopack aspirators. Three samplings, each of five consecutive days, were conducted during the long-rains, short-rains and dry season for each city. Inter-city and seasonal variation in mosquito abundance and diversity was evaluated using general linear models while mosquito-resting preference (indoors vs outdoors) was compared using Chi-square test. Aedes aegypti, which comprised 60% (n = 7772) of the total 12,937 host-seeking mosquitoes collected, had comparable numbers in Kisumu (45.2%, n = 3513) and Kilifi (37.7%, n = 2932), both being significantly higher than Nairobi (17.1%, n = 1327). Aedes aegypti abundance was significantly lower in the short-rains and dry season relative to the long-rains (P < 0.0001). Aedes bromeliae, which occurred in low numbers, did not differ significantly between seasons or cities. Mosquito diversity was highest during the long-rains and in Nairobi. Only 10% (n = 43) of the 450 houses aspirated were found positive for resting Ae. aegypti

  8. Techniques for Nonterminal Blood Sampling in Black-Tailed Prairie Dogs (Cynomys ludovicianus).

    PubMed

    Head, Valerie; Eshar, David; Nau, Melissa R

    2017-03-01

    Black-tailed prairie dogs (Cynomys ludovicianus) are used as an animal model for research on gallbladder stones and several infectious diseases. A comprehensive, instructive resource regarding the appropriate techniques for venipuncture and collection of nonterminal blood samples in this species has not yet been published. Blood samples (1 mL or larger) were readily obtained from the jugular vein, femoral vein, or cranial vena cava, whereas peripheral sites, such as the cephalic vein, saphenous vein, and tarsal vein, mainly were useful for obtaining smaller volumes. The detailed and illustrated information presented here can aid clinicians and researchers in performing venipuncture, anesthesia, and handling of this species.

  9. [Private umbilical cord blood banking does not reduce the number of samples for scientific stem cell research].

    PubMed

    Jacobs, V R; Niemeyer, M; Gottschalk, N; Schneider, K T; Kiechle, M

    2005-12-01

    Private umbilical cord blood (UCB) banking after delivery has increased over the last decade. For adult/somatic stem cell research UCB is an essential source of stem cells and researchers question if the number of UCB samples for research might be reduced by private banking. A survey among seven private blood banks in Germany and analysis and comparison of the number of UCB samples donated for research within the STEMMAT project with private blood banking were performed from 03/2003 to 06/2005 at the Frauenklinik (OB/GYN), Technical University Munich, Germany. Within 27.5 months 1,551 UCB samples were collected for research purposes; the effective recruitment rate was higher than expectations at an effective 66.2 %. Private UCB banking [n = 24] was distributed among three cord blood banks [n = 16, 6 and 4]. The rate of private blood banking was 0.99 % for all deliveries, thus reducing the effective rate for research purpose by only 1.5 %. Under the assumption of active and successful recruitment of scientific UCB samples, private blood banking does not significantly reduce this rate and therefore is a negligible rival in the competition for sufficient numbers of UCB samples for research.

  10. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    PubMed

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  11. Blood donation behaviour and beliefs among a sample of high school students in Mmabatho.

    PubMed

    Mwaba, K; Keikelame, M J

    1995-08-01

    This study was aimed at establishing the extent of blood donation and beliefs about donating blood among high school students in Mmabatho. A random sample of 40 Standard 10 students (20 males, 20 females; mean age = 20.8 years) was selected to participate in the study. A structured questionnaire was used to determined blood donation behaviour and accompanying beliefs. The results showed that although 80 percent of the participants believed that donating blood was important only 17.5 percent had actually ever donated blood. The data also showed that donating blood was a health risk or were uncertain if donating blood was safe. It is recommended that public appeals for blood donors should include information to dispel myths about dangers of donating blood.

  12. Physiological and Pathological Impact of Blood Sampling by Retro-Bulbar Sinus Puncture and Facial Vein Phlebotomy in Laboratory Mice

    PubMed Central

    Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter

    2014-01-01

    Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941

  13. Cerebral Oxygenation and Pain of Heel Blood Sampling Using Manual and Automatic Lancets in Premature Infants.

    PubMed

    Hwang, Mi-Jung; Seol, Geun Hee

    2015-01-01

    Heel blood sampling is a common but painful procedure for neonates. Automatic lancets have been shown to be more effective, with reduced pain and tissue damage, than manual lancets, but the effects of lancet type on cortical activation have not yet been compared. The study aimed to compare the effects of manual and automatic lancets on cerebral oxygenation and pain of heel blood sampling in 24 premature infants with respiratory distress syndrome. Effectiveness was measured by assessing numbers of pricks and squeezes and duration of heel blood sampling. Pain responses were measured using the premature infant pain profile score, heart rate, and oxygen saturation (SpO2). Regional cerebral oxygen saturation (rScO2) was measured using near-infrared spectroscopy, and cerebral fractional tissue oxygen extraction was calculated from SpO2 and rScO. Measures of effectiveness were significantly better with automatic than with manual lancing, including fewer heel punctures (P = .009) and squeezes (P < .001) and shorter duration of heel blood sampling (P = .002). rScO2 was significantly higher (P = .013) and cerebral fractional tissue oxygen extraction after puncture significantly lower (P = .040) with automatic lancing. Premature infant pain profile scores during (P = .004) and after (P = .048) puncture were significantly lower in the automatic than in the manual lancet group. Automatic lancets for heel blood sampling in neonates with respiratory distress syndrome significantly reduced pain and enhanced cerebral oxygenation, suggesting that heel blood should be sampled routinely using an automatic lancet.

  14. Successful increase in contraceptive uptake among Kenyan HIV-1-serodiscordant couples enrolled in an HIV-1 prevention trial.

    PubMed

    Ngure, Kenneth; Heffron, Renee; Mugo, Nelly; Irungu, Elizabeth; Celum, Connie; Baeten, Jared M

    2009-11-01

    To evaluate a multipronged approach to promote dual contraceptive use by women within heterosexual HIV-1-serodiscordant partnerships. For 213 HIV-1-serodiscordant couples in Thika, Kenya, participating in an HIV-1 prevention clinical trial, contraceptive promotion was initiated through a multipronged intervention that included staff training, couples family planning sessions, and free provision of hormonal contraception on-site. Contraceptive use and pregnancy incidence were compared between two time periods (before versus after June 2007, when the intervention was initiated) and between Thika and other Kenyan trial sites (Eldoret, Kisumu, and Nairobi). Generalized estimating equations and Andersen-Gill proportional hazards modeling were used. Nonbarrier contraceptive use increased after implementation of the intervention: from 31.5 to 64.7% of visits among HIV-1-seropositive women [odds ratio 4.0, 95% confidence interval (CI) 3.0-5.3] and from 28.6 to 46.7% of visits among HIV-1-seronegative women (odds ratio 2.2, 95% CI 1.4-3.5). In comparison, at the other Kenyan sites, where the intervention was not implemented, contraceptive use changed minimally, from 15.6 to 22.3% of visits for HIV-1-seropositive women and from 13.6 to 12.7% among HIV-1-seronegative women. Self-reported condom use remained high during follow-up. Pregnancy incidence at the Thika was significantly lower after compared with before June 2007 (hazard ratio 0.2, 95% CI 0.1-0.6) and was approximately half that at other Kenyan sites during the intervention period (hazard ratio 0.5, 95% CI 0.3-0.8). A multipronged family planning intervention can lead to high nonbarrier contraceptive uptake and reduced pregnancy incidence among women in HIV-1-serodiscordant partnerships.

  15. Successful increase in contraceptive uptake among Kenyan HIV-1 serodiscordant couples enrolled in an HIV-1 prevention trial

    PubMed Central

    Ngure, Kenneth; Heffron, Renee; Mugo, Nelly; Irungu, Elizabeth; Celum, Connie; Baeten, Jared

    2016-01-01

    Objective To evaluate a multi-pronged approach to promote dual contraceptive use by women within heterosexual HIV-1 serodiscordant partnerships. Methods For 213 HIV-1 serodiscordant couples in Thika, Kenya participating in an HIV-1 prevention clinical trial, contraceptive promotion was initiated through a multi-pronged intervention that included staff training, couples family planning sessions, and free provision of hormonal contraception on-site. Contraceptive use and pregnancy incidence were compared between two time periods (before versus after June 2007, when the intervention was initiated) and between Thika and other Kenyan trial sites (Eldoret, Kisumu, and Nairobi). Generalized estimating equations and Andersen-Gill proportional hazards modeling were used. Results Non-barrier contraceptive use increased after implementation of the intervention: from 31.5% to 64.7% of visits among HIV-1 seropositive women (odds ratio [OR] 4.0, 95% confidence interval [CI] 3.0–5.3) and from 28.6% to 46.7% of visits among HIV-1 seronegative women (OR 2.2, 95% CI 1.4–3.5). In comparison, at the other Kenyan sites, where the intervention was not implemented, contraceptive use changed minimally, from 15.6% to 22.3% of visits for HIV-1 seropositive women and from 13.6% to 12.7% among HIV-1 seronegative women. Self-reported condom use remained high during follow-up. Pregnancy incidence at the Thika was significantly lower after compared with before June 2007 (hazard ratio [HR] 0.2, 95% CI 0.1–0.6), and was approximately half that at other Kenyan sites during the intervention period (HR 0.5, 95% CI 0.3–0.8). Conclusions A multi-pronged family planning intervention can lead to high non-barrier contraceptive uptake and reduced pregnancy incidence among women in HIV-1 serodiscordant partnerships. PMID:20081393

  16. Informal, Moralistic Health Education in Kenyan Teacher Education and How It Influences the Professional Identity of Student-Teachers

    ERIC Educational Resources Information Center

    Dahl, Kari K. B.

    2015-01-01

    This study explores informal health education with a moralistic content in three Kenyan teacher training colleges and what it means for the development of a professional identity in health education student-teachers on a continent affected by far the largest number of health problems. Informal health education with a moralistic content is a kind…

  17. Capillary blood sampling as an alternative to venipuncture in the assessment of serum 25 hydroxyvitamin D levels.

    PubMed

    Dayre McNally, J; Matheson, Loren A; Sankaran, Koravangattu; Rosenberg, Alan M

    2008-11-01

    This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.

  18. Kinetic modeling of PET-FDG in the brain without blood sampling.

    PubMed

    Bentourkia, M'hamed

    2006-12-01

    The aim in this work is to report a new method to calculate parametric images from a single scan acquisition with positron emission tomography (PET) and fluorodeoxyglucose (FDG) in the human brain without blood sampling. It is usually practical for research or clinical purposes to inject the patient in an isolated room and to start the PET acquisition only for some 10-20 min, about 30 min after FDG injection. In order to calculate the cerebral metabolic rates for glucose (CMRG), usually several blood samples are required. The proposed method considers the relation between the uptake of the tracer in the cerebellum as a reference tissue and the population based input curve. Similar results were obtained for CMRG values with the present method in comparison to the usual autoradiographic and the non-linear least squares fitting of regions of interest.

  19. Preanalytical blood sample workup for cell-free DNA analysis using Droplet Digital PCR for future molecular cancer diagnostics.

    PubMed

    van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H

    2017-10-01

    In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  20. Method of evaluation of process of red blood cell sedimentation based on photometry of droplet samples.

    PubMed

    Aristov, Alexander; Nosova, Ekaterina

    2017-04-01

    The paper focuses on research aimed at creating and testing a new approach to evaluate the processes of aggregation and sedimentation of red blood cells for purpose of its use in clinical laboratory diagnostics. The proposed method is based on photometric analysis of blood sample formed as a sessile drop. The results of clinical approbation of this method are given in the paper. Analysis of the processes occurring in the sample in the form of sessile drop during the process of blood cells sedimentation is described. The results of experimental studies to evaluate the effect of the droplet sample focusing properties on light radiation transmittance are presented. It is shown that this method significantly reduces the sample volume and provides sufficiently high sensitivity to the studied processes.

  1. Range of therapeutic prothipendyl and prothipendyl sulfoxide concentrations in clinical blood samples.

    PubMed

    Krämer, Michael; Heese, Peter; Banger, Markus; Madea, Burkhard; Hess, Cornelius

    2018-06-01

    Due to a lack of reference blood concentrations in the literature, the forensic evaluation of prothipendyl findings in blood samples is difficult. Interpretations with regard to the assessment of blood concentrations as well as an estimation of the ingested prothipendyl amounts were often vague. To describe a concentration range in clinical samples, prothipendyl and prothipendyl sulfoxide concentrations were determined in serum samples of 50 psychiatric patients receiving 40 mg, 80 mg, or 160 mg doses of prothipendyl. The analyses of prothipendyl and prothipendyl sulfoxide were carried out using validated methods of high performance liquid chromatography coupled to triple quadrupole mass spectrometry (LC-QQQ-MS), respectively. 40 mg doses caused average prothipendyl serum concentrations of 18.0 ng/mL (1 hour after intake) and 7.9 ng/mL (10.5 hours after intake), while 80 mg doses caused averages of 42.6 ng/mL and 15.2 ng/mL at the mentioned times of sampling. Irrespective of the given dose, prothipendyl concentrations below 30 ng/mL were observed in 80% of the patient samples taken 1 hour after ingestion as well as in 90% of the samples collected 10.5 hours after administration. Serum concentrations of the Phase I metabolite prothipendyl sulfoxide averaged 4.3 ng/mL (1 hour after intake) and 3.6 ng/mL (10.5 hours after intake). Possible drug-drug interactions regarding absorption and metabolism of prothipendyl are discussed. Results of the herein presented study are useful for the interpretation of analytical prothipendyl findings in forensic toxicology. The utility of the described concentration range is demonstrated by discussing two death cases involving prothipendyl findings. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Concentrations of zolpidem and zopiclone in venous blood samples from impaired drivers compared with femoral blood from forensic autopsies.

    PubMed

    Jones, Alan Wayne; Holmgren, Anita

    2012-10-10

    The concentrations of zolpidem and zopiclone were determined in peripheral blood samples in two forensic materials collected over a 10-year period (2001-2010). The z-hypnotics were determined in venous blood from living subjects (impaired drivers) and in femoral blood from deceased persons (forensic autopsies), with the latter classified as intoxication or other causes of death. The z-hypnotics were determined in blood by capillary column gas chromatography (GC) with a nitrogen-phosphorous (N-P) detector after solvent extraction with n-butyl acetate. The analytical limit of quantitation (LOQ) was 0.02 mg/L for zopiclone and 0.05 mg/L for zolpidem and these have remained unchanged throughout the study. When death was attributed to drug intoxication (N=918), the median concentration of zopiclone in blood was 0.20 mg/L compared with 0.06 mg/L for other causes of death (N=1215) and 0.07 mg/L in traffic offenders (N=691) (p<0.001). Likewise, a higher median concentration (0.30 mg/L) was found in intoxication deaths involving zolpidem (N=357) compared with 0.13 mg/L for other causes of death (N=397) or 0.19 mg/L in impaired drivers (N=837) (p<0.001). Median concentration in blood of both z-hypnotics were appreciably higher in intoxication deaths when no other substances were identified; 0 70 mg/L (N=12) for zopiclone and 1.35 mg/L (N=12) for zolpidem. The median concentrations of z-hypnotics in blood decreased as the number of co-ingested substances increased for intoxication deaths but not other causes of death. The most prevalent co-ingested substances were ethanol in autopsy cases and diazepam in the motorists. This large compilation of forensic cases should prove useful when toxicologists are required to interpret concentrations of z-hypnotics in blood samples in relation to cause of death. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Sensitivity of nested-PCR for plasmodium detection in pooled whole blood samples and its usefulness to blood donor screening in endemic areas.

    PubMed

    de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen

    2014-04-01

    Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Chemometric techniques on the analysis of Raman spectra of serum blood samples of breast cancer patients

    NASA Astrophysics Data System (ADS)

    Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.

    2008-02-01

    Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.

  5. Comparison between dried blood spot and plasma sampling for therapeutic drug monitoring of antiepileptic drugs in children with epilepsy: A step towards home sampling.

    PubMed

    Linder, Camilla; Wide, Katarina; Walander, Malin; Beck, Olof; Gustafsson, Lars L; Pohanka, Anton

    2017-05-01

    To investigate if dried blood spots could be used for therapeutic drug monitoring of the antiepileptic drugs, carbamazepine, lamotrigine and valproic acid in children with epilepsy. Fingerprick blood samples from 46 children at a neuropediatric outpatient clinic was collected on filterpaper at the same time as capillary plasma sampling. A validated dried blood spot liquid chromatography tandem mass spectrometry method for carbamazepine, lamotrigine and valproic acid was compared with the routine plasma laboratory methods. Method agreement was evaluated and plasma concentrations were estimated by different conversion approaches. Strong correlation was shown between dried blood spot and plasma concentrations for all three drugs, with R2 values>0.89. Regression analysis showed a proportional bias with 35% lower dried blood spot concentrations for valproic acid (n=33) and concentrations were 18% higher for carbamazepine (n=17). A ratio approach was used to make a conversion from dried blood spots to estimated plasma for these two drugs. Dried blood spot concentrations were directly comparable with plasma for lamotrigine (n=20). This study supports that dried blood spot concentrations can be used as an alternative to plasma in a children population for three commonly used antiepileptic drugs with the possibility to expand by adding other antiepileptic drugs. Clinical decisions can be made based on converted (carbamazepine, valproic acid) or unconverted (lamotrigine) dried blood spot concentrations. Dried blood spot sampling, in the future taken at home, will simplify an effective therapeutic drug monitoring for this group of patients who often have concomitant disorders and also reduce costs for society. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. PCR-based detection of Toxoplasma gondii DNA in blood and ocular samples for diagnosis of ocular toxoplasmosis.

    PubMed

    Bourdin, C; Busse, A; Kouamou, E; Touafek, F; Bodaghi, B; Le Hoang, P; Mazier, D; Paris, L; Fekkar, A

    2014-11-01

    PCR detection of Toxoplasma gondii in blood has been suggested as a possibly efficient method for the diagnosis of ocular toxoplasmosis (OT) and furthermore for genotyping the strain involved in the disease. To assess this hypothesis, we performed PCR with 121 peripheral blood samples from 104 patients showing clinical and/or biological evidence of ocular toxoplasmosis and from 284 (258 patients) controls. We tested 2 different extraction protocols, using either 200 μl (small volume) or 2 ml (large volume) of whole blood. Sensitivity was poor, i.e., 4.1% and 25% for the small- and large-volume extractions, respectively. In comparison, PCR with ocular samples yielded 35.9% sensitivity, while immunoblotting and calculation of the Goldmann-Witmer coefficient yielded 47.6% and 72.3% sensitivities, respectively. Performing these three methods together provided 89.4% sensitivity. Whatever the origin of the sample (ocular or blood), PCR provided higher sensitivity for immunocompromised patients than for their immunocompetent counterparts. Consequently, PCR detection of Toxoplasma gondii in blood samples cannot currently be considered a sufficient tool for the diagnosis of OT, and ocular sampling remains necessary for the biological diagnosis of OT. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  7. Genetic diversity of Kenyan native oyster mushroom (Pleurotus).

    PubMed

    Otieno, Ojwang D; Onyango, Calvin; Onguso, Justus Mungare; Matasyoh, Lexa G; Wanjala, Bramwel W; Wamalwa, Mark; Harvey, Jagger J W

    2015-01-01

    Members of the genus Pleurotus, also commonly known as oyster mushroom, are well known for their socioeconomic and biotechnological potentials. Despite being one of the most important edible fungi, the scarce information about the genetic diversity of the species in natural populations has limited their sustainable utilization. A total of 71 isolates of Pleurotus species were collected from three natural populations: 25 isolates were obtained from Kakamega forest, 34 isolates from Arabuko Sokoke forest and 12 isolates from Mount Kenya forest. Amplified fragment length polymorphism (AFLP) was applied to thirteen isolates of locally grown Pleurotus species obtained from laboratory samples using five primer pair combinations. AFLP markers and internal transcribed spacer (ITS) sequences of the ribosomal DNA were used to estimate the genetic diversity and evaluate phylogenetic relationships, respectively, among and within populations. The five primer pair combinations generated 293 polymorphic loci across the 84 isolates. The mean genetic diversity among the populations was 0.25 with the population from Arabuko Sokoke having higher (0.27) diversity estimates compared to Mount Kenya population (0.24). Diversity between the isolates from the natural population (0.25) and commercial cultivars (0.24) did not differ significantly. However, diversity was greater within (89%; P > 0.001) populations than among populations. Homology search analysis against the GenBank database using 16 rDNA ITS sequences randomly selected from the two clades of AFLP dendrogram revealed three mushroom species: P. djamor, P. floridanus and P. sapidus; the three mushrooms form part of the diversity of Pleurotus species in Kenya. The broad diversity within the Kenyan Pleurotus species suggests the possibility of obtaining native strains suitable for commercial cultivation. © 2015 by The Mycological Society of America.

  8. Service delivery in Kenyan district hospitals – what can we learn from literature on mid-level managers?

    PubMed Central

    2013-01-01

    Background There is a growing emphasis on the need to tackle inadequate human resources for health (HRH) as an essential part of strengthening health systems; but the focus is mostly on macro-level issues, such as training, recruitment, skill mix and distribution. Few attempts have been made to understand the capability of health workers, their motivation and other structural and organizational aspects of systems that influence workforce performance. We have examined literature on the roles of mid-level managers to help us understand how they might influence service delivery quality in Kenyan hospitals. In the Kenyan hospital settings, these are roles that head of departments who are also clinical or nursing service providers might play. Methods A computerized search strategy was run in Pub Med, Cochrane Library, Directory of Open Access Journals Social Science Research Network, Eldis, Google Scholar and Human Resources for Health web site databases using both free-text and MeSH terms from 1980 to 2011. In addition, citation searching from excluded and included articles was used and relevant unpublished literature systematically identified. Results and discussion A total of 23 articles were finally included in the review from over 7000 titles and abstracts initially identified. The most widely documented roles of mid-level managers were decision-making or problem-solving, strategist or negotiator and communicator. Others included being a therapist or motivator, goal setting or articulation and mentoring or coaching. In addition to these roles, we identified important personal attributes of a good manager, which included interpersonal skills, delegation and accountability, and honesty. The majority of studies included in the review concerned the roles that mid-level managers are expected to play in times of organizational change. Conclusion This review highlights the possible significance of mid-level managers in achieving delivery of high-quality services in Kenyan

  9. Gram-negative and -positive bacteria differentiation in blood culture samples by headspace volatile compound analysis.

    PubMed

    Dolch, Michael E; Janitza, Silke; Boulesteix, Anne-Laure; Graßmann-Lichtenauer, Carola; Praun, Siegfried; Denzer, Wolfgang; Schelling, Gustav; Schubert, Sören

    2016-12-01

    Identification of microorganisms in positive blood cultures still relies on standard techniques such as Gram staining followed by culturing with definite microorganism identification. Alternatively, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or the analysis of headspace volatile compound (VC) composition produced by cultures can help to differentiate between microorganisms under experimental conditions. This study assessed the efficacy of volatile compound based microorganism differentiation into Gram-negatives and -positives in unselected positive blood culture samples from patients. Headspace gas samples of positive blood culture samples were transferred to sterilized, sealed, and evacuated 20 ml glass vials and stored at -30 °C until batch analysis. Headspace gas VC content analysis was carried out via an auto sampler connected to an ion-molecule reaction mass spectrometer (IMR-MS). Measurements covered a mass range from 16 to 135 u including CO2, H2, N2, and O2. Prediction rules for microorganism identification based on VC composition were derived using a training data set and evaluated using a validation data set within a random split validation procedure. One-hundred-fifty-two aerobic samples growing 27 Gram-negatives, 106 Gram-positives, and 19 fungi and 130 anaerobic samples growing 37 Gram-negatives, 91 Gram-positives, and two fungi were analysed. In anaerobic samples, ten discriminators were identified by the random forest method allowing for bacteria differentiation into Gram-negative and -positive (error rate: 16.7 % in validation data set). For aerobic samples the error rate was not better than random. In anaerobic blood culture samples of patients IMR-MS based headspace VC composition analysis facilitates bacteria differentiation into Gram-negative and -positive.

  10. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    PubMed

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged <8 years, 83% of those aged 9-18 years and 73% of those aged >18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  11. Clinical and anatomic pathology effects of serial blood sampling in rat toxicology studies, using conventional or microsampling methods.

    PubMed

    Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique

    2015-08-01

    As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Isolation and molecular characterization of Fikirini rhabdovirus, a novel virus from a Kenyan bat.

    PubMed

    Kading, Rebekah C; Gilbert, Amy T; Mossel, Eric C; Crabtree, Mary B; Kuzmin, Ivan V; Niezgoda, Michael; Agwanda, Bernard; Markotter, Wanda; Weil, M Ryan; Montgomery, Joel M; Rupprecht, Charles E; Miller, Barry R

    2013-11-01

    Zoonotic and vector-borne pathogens have comprised a significant component of emerging human infections in recent decades, and bats are increasingly recognized as reservoirs for many of these disease agents. To identify novel pathogens associated with bats, we screened tissues of bats collected in Kenya. Virus isolates were identified by next generation sequencing of viral nucleic acid preparations from the infected cell culture supernatant and characterized. Here we report the identification of Fikirini rhabdovirus, a novel rhabdovirus isolated from a bat, Hipposideros vittatus, captured along the Kenyan coast.

  13. A SENSITIVE METHOD FOR THE DETERMINATION OF CARBOXYHAEMOGLOBIN IN A FINGER PRICK SAMPLE OF BLOOD

    PubMed Central

    Commins, B. T.; Lawther, P. J.

    1965-01-01

    About 0·01 ml. of blood taken from a finger prick is dissolved in 10 ml. of 0·04% ammonia solution. The solution is divided into two halves, and oxygen is bubbled through one half to convert any carboxyhaemoglobin into oxyhaemoglobin. The spectra of the two halves are then compared in a spectrophotometer, and the difference between them is used to estimate the carboxyhaemoglobin content of the blood either graphically or by calculation from a simple formula. Calibration is simple and need only be done once. A sample of blood can be analysed in about 20 minutes, which includes the time to collect the sample. The method is sensitive enough to be used for the analysis of solutions of blood containing less than 1% carboxyhaemoglobin. PMID:14278801

  14. Analysis of Hemoglobin A1c from Dried Blood Spot Samples with the Tina-quant® II Immunoturbidimetric Method

    PubMed Central

    Jones, Trevor G.; Warber, Kimbrough D.; Roberts, Billy D.

    2010-01-01

    Background Hemoglobin A1c (HbA1c) has been endorsed as a tool for the diagnosis of diabetes. This test requires instrumentation that may not be available in underdeveloped areas. Dried blood spot (DBS) samples collected by finger stick procedures offer a mechanism to transport samples to laboratories that do measure HbA1c. Methods Whole blood (ethylenediaminetetraacetic acid) was applied to Ahlstrom 226 filter paper. These DBS samples were compared to whole blood samples using the Roche Tina-quant® II immunoturbidometric assay. Hemoglobin A1c stability on DBS was assessed at three temperatures—4, 25, and 40°C—for up to 9 days. A 44-day study was also done for DBS at 20–25°C. Results The Tina-quant® II DBS method showed excellent agreement with whole blood HbA1c results (r2 = 0.99) with a slight positive mean bias of 0.08 ± 0.04% HbA1c (95% confidence interval). The variation in HbA1c on DBS samples subjected to different temperatures and times did not exceed 5.6%. Conclusions Dried blood spot samples represent an alternative to whole blood for HbA1c by measurement when transporting whole blood is not feasible. PMID:20307383

  15. Diversity in Education: Kenyan Sign Language as a Medium of Instruction in Schools for the Deaf in Kenya

    ERIC Educational Resources Information Center

    Mweri, Jefwa G.

    2014-01-01

    In Kenya, the only official document that deals with the use of mother tongue (MT) in Schools is the 1967 Gachathi report. The report has clear-cut guidance and policy regarding MT use by the hearing children. However, for deaf children, no such policy exists; therefore, the use of the deaf child's MT (Kenyan Sign Language (KSL)) in schools for…

  16. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  17. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    PubMed

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  18. Creatinine measurement on dry blood spot sample for chronic kidney disease screening.

    PubMed

    Silva, Alan Castro Azevedo E; Gómez, Juan Fidel Bencomo; Lugon, Jocemir Ronaldo; Graciano, Miguel Luis

    2016-03-01

    Chronic kidney disease (CKD) screening is advisable due to its high morbidity and mortality and is usually performed by sampling blood and urine. Here we present an innovative and simpler method, by measuring creatinine on a dry blood spot on filter paper. One-hundred and six individuals at high risk for CKD were enrolled. The creatinine values obtained using both tests and the demographic data of each participant allowed us to determinate the eGFR. The adopted cutoff for CKD was an eGFR < 60 ml/min. Mean age was 57 ± 12 years, 74% were female, 40% white, and 60% non-white. Seventy-six percent were hypertensive, 30% diabetic, 37% had family history of CKD, and 22% of smoking. The BMI was 29.5 ± 6.9 kg/m2, median systolic blood pressure was 125 mmHg (IQR 120-140 mmHg) and median diastolic blood pressure was 80 mmHg (IQR 70-80 mmHg). According to MDRD equation, sensitivity was 96%, specificity 55%, predictive positive value 96%, predictive negative value 55% and accuracy 92%. By the CKD-EPI equation the sensitivity was 94%, specificity 55%, predictive positive value 94%, predictive negative value 55% and accuracy 90%. A Bland and Altman analysis showed a relatively narrow range of creatinine values differences (+ 0.68mg/dl to -0.55mg/dl) inside the ± 1.96 SD, without systematic differences. Measurement of creatinine on dry blood sample is an easily feasible non-invasive diagnostic test with good accuracy that may be useful to screen chronic kidney disease.

  19. Using dried blood spot sampling to improve data quality and reduce animal use in mouse pharmacokinetic studies.

    PubMed

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-03-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.

  20. Using Dried Blood Spot Sampling to Improve Data Quality and Reduce Animal Use in Mouse Pharmacokinetic Studies

    PubMed Central

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-01-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  1. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    PubMed

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  2. Beneath the Surface: A Narrative Inquiry into Educational and Cultural Experiences of Kenyan Adult Women Learners in U.S.A. Universities

    ERIC Educational Resources Information Center

    Gatua, Mary Wairimu

    2011-01-01

    This qualitative study examines educational and socio-cultural experiences of seven Kenyan women pursuing higher education in the United States. The study uses in depth interviews to explore the participants' socio-cultural experiences, how they negotiate their multiple identities, and their transformative learning experiences. Three theoretical…

  3. Corruption in the Kenya Police Force and Impacts on Kenyan Security: Investigating the Need for Police Reforms

    DTIC Science & Technology

    2017-03-21

    against the citizens. Kenya Police have always been linked with abuse of power with impunity when tackling crime or executing their duties. For example...Therefore, ethical police code of conducts in American 14 policing were established in the efforts to control excessive use of power while...occurs when the police encounter with the citizens during their routine enforcement of the law. The high -level of negative attitudes among Kenyans to the

  4. The subtyping of primary aldosteronism by adrenal vein sampling: sequential blood sampling causes factitious lateralization.

    PubMed

    Rossitto, Giacomo; Battistel, Michele; Barbiero, Giulio; Bisogni, Valeria; Maiolino, Giuseppe; Diego, Miotto; Seccia, Teresa M; Rossi, Gian Paolo

    2018-02-01

    The pulsatile secretion of adrenocortical hormones and a stress reaction occurring when starting adrenal vein sampling (AVS) can affect the selectivity and also the assessment of lateralization when sequential blood sampling is used. We therefore tested the hypothesis that a simulated sequential blood sampling could decrease the diagnostic accuracy of lateralization index for identification of aldosterone-producing adenoma (APA), as compared with bilaterally simultaneous AVS. In 138 consecutive patients who underwent subtyping of primary aldosteronism, we compared the results obtained simultaneously bilaterally when starting AVS (t-15) and 15 min after (t0), with those gained with a simulated sequential right-to-left AVS technique (R ⇒ L) created by combining hormonal values obtained at t-15 and at t0. The concordance between simultaneously obtained values at t-15 and t0, and between simultaneously obtained values and values gained with a sequential R ⇒ L technique, was also assessed. We found a marked interindividual variability of lateralization index values in the patients with bilaterally selective AVS at both time point. However, overall the lateralization index simultaneously determined at t0 provided a more accurate identification of APA than the simulated sequential lateralization indexR ⇒ L (P = 0.001). Moreover, regardless of which side was sampled first, the sequential AVS technique induced a sequence-dependent overestimation of lateralization index. While in APA patients the concordance between simultaneous AVS at t0 and t-15 and between simultaneous t0 and sequential technique was moderate-to-good (K = 0.55 and 0.66, respectively), in non-APA patients, it was poor (K = 0.12 and 0.13, respectively). Sequential AVS generates factitious between-sides gradients, which lower its diagnostic accuracy, likely because of the stress reaction arising upon starting AVS.

  5. Staphylococcus aureus detection in blood samples by silica nanoparticle-oligonucleotides conjugates.

    PubMed

    Borsa, Baris A; Tuna, Bilge G; Hernandez, Frank J; Hernandez, Luiza I; Bayramoglu, Gulay; Arica, M Yakup; Ozalp, V Cengiz

    2016-12-15

    A fast, specific and sensitive homogeneous assay for Staphylococcus aureus detection was developed by measuring the activity of secreted nuclease from the bacteria via a modified DNA oligonucleotide. As biosensor format, an effective system, Nanokeepers as previously reported, were used for triggered release of confined fluorophores, and hence specific detection of S. aureus on nuclease activity was obtained. The interference from blood components for fluorescent quantification was eliminated by a pre-purification by aptamer-functionalized silica magnetic nanoparticles. The reported assay system was exclusively formed by nucleic acid oligos and magnetic or mesoporous silica nanoparticles, that can be used on blood samples in a stepwise manner. The assay was successfully used as a sensing platform for the specific detection of S. aureus cells as low as 682 CFU in whole blood. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Application of Atomic Dielectric Resonance Spectroscopy for the screening of blood samples from patients with clinical variant and sporadic CJD

    PubMed Central

    Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L

    2007-01-01

    Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958

  7. Novel genotype of Ehrlichia canis detected in samples of human blood bank donors in Costa Rica.

    PubMed

    Bouza-Mora, Laura; Dolz, Gaby; Solórzano-Morales, Antony; Romero-Zuñiga, Juan José; Salazar-Sánchez, Lizbeth; Labruna, Marcelo B; Aguiar, Daniel M

    2017-01-01

    This study focuses on the detection and identification of DNA and antibodies to Ehrlichia spp. in samples of blood bank donors in Costa Rica using molecular and serological techniques. Presence of Ehrlichia canis was determined in 10 (3.6%) out of 280 blood samples using polymerase chain reaction (PCR) targeting the ehrlichial dsb conserved gene. Analysis of the ehrlichial trp36 polymorphic gene in these 10 samples revealed substantial polymorphism among the E. canis genotypes, including divergent tandem repeat sequences. Nucleotide sequences of dsb and trp36 amplicons revealed a novel genotype of E. canis in blood bank donors from Costa Rica. Indirect immunofluorescence assay (IFA) detected antibodies in 35 (35%) of 100 serum samples evaluated. Thirty samples showed low endpoint titers (64-256) to E. canis, whereas five sera yielded high endpoint titers (1024-8192); these five samples were also E. canis-PCR positive. These findings represent the first report of the presence of E. canis in humans in Central America. Copyright © 2016 Elsevier GmbH. All rights reserved.

  8. Blood Sampling and Preparation Procedures for Proteomic Biomarker Studies of Psychiatric Disorders.

    PubMed

    Guest, Paul C; Rahmoune, Hassan

    2017-01-01

    A major challenge in proteomic biomarker discovery and validation for psychiatric diseases is the inherent biological complexity underlying these conditions. There are also many technical issues which hinder this process such as the lack of standardization in sampling, processing and storage of bio-samples in preclinical and clinical settings. This chapter describes a reproducible procedure for sampling blood serum and plasma that is specifically designed for maximizing data quality output in two-dimensional gel electrophoresis, multiplex immunoassay and mass spectrometry profiling studies.

  9. Prior exercise alters the difference between arterialised and venous glycaemia: implications for blood sampling procedures.

    PubMed

    Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Betts, James A; Thompson, Dylan; Walhin, Jean-Philippe; Gonzalez, Javier T

    2017-05-01

    Oral glucose tolerance and insulin sensitivity are common measures, but are determined using various blood sampling methods, employed under many different experimental conditions. This study established whether measures of oral glucose tolerance and oral glucose-derived insulin sensitivity (insulin sensitivity indices; ISI) differ when calculated from venous v. arterialised blood. Critically, we also established whether any differences between sampling methods are consistent across distinct metabolic conditions (after rest v. after exercise). A total of ten healthy men completed two trials in a randomised order, each consisting of a 120-min oral glucose tolerance test (OGTT), either at rest or post-exercise. Blood was sampled simultaneously from a heated hand (arterialised) and an antecubital vein of the contralateral arm (venous). Under both conditions, glucose time-averaged AUC was greater from arterialised compared with venous plasma but importantly, this difference was larger after rest relative to after exercise (0·99 (sd 0·46) v. 0·56 (sd 0·24) mmol/l, respectively; P<0·01). OGTT-derived ISIMatsuda and ISICederholm were lower when calculated from arterialised relative to venous plasma and the arterialised-venous difference was greater after rest v. after exercise (ISIMatsuda: 1·97 (sd 0·81) v. 1·35 (sd 0·57) arbitrary units (au), respectively; ISICederholm : 14·76 (sd 7·83) v. 8·70 (sd 3·95) au, respectively; both P<0·01). Venous blood provides lower postprandial glucose concentrations and higher estimates of insulin sensitivity, compared with arterialised blood. Most importantly, these differences between blood sampling methods are not consistent after rest v. post-exercise, preventing standardised venous-to-arterialised corrections from being readily applied.

  10. Semen Bacterial Concentrations and HIV-1 RNA Shedding Among HIV-1-Seropositive Kenyan Men.

    PubMed

    Korhonen, Christine J; Srinivasan, Sujatha; Huang, Dandi; Ko, Daisy L; Sanders, Eduard J; Peshu, Norbert M; Krieger, John N; Muller, Charles H; Coombs, Robert W; Fredricks, David N; Graham, Susan M

    2017-03-01

    HIV-1 is transmitted through semen from men to their sexual partners. Genital infections can increase HIV-1 RNA shedding in semen, but shedding also occurs in the absence of typical pathogens. We hypothesized that higher bacterial concentrations in semen would be associated with higher HIV-1 RNA levels. We analyzed semen samples from 42 HIV-1-seropositive Kenyan men using quantitative polymerase chain reaction (PCR) to assess bacterial concentrations and real-time PCR to measure HIV-1 RNA levels. Generalized estimation equations were used to evaluate associations between these 2 measures. Broad-range 16S rRNA gene PCR with pyrosequencing was performed on a subset of 13 samples to assess bacterial community composition. Bacteria were detected in 96.6% of 88 samples by quantitative PCR. Semen bacterial concentration and HIV-1 RNA levels were correlated 0.30 (P = 0.01). The association between bacterial concentration and HIV-1 RNA detection was not significant after adjustment for antiretroviral therapy (ART) (adjusted odds ratio: 1.27, 95% CI: 0.84 to 1.91). Factors associated with semen bacterial concentration included insertive anal sex (adjusted beta 0.92, 95% CI: 0.12 to 1.73) and ART use (adjusted beta: -0.77, 95% CI: -1.50 to 0.04). Among 13 samples with pyrosequencing data, Corynebacterium spp., Staphylococcus spp., and Streptococcus spp. were most frequently detected. Most of these HIV-1-infected men had bacteria in their semen. ART use was associated with undetectable semen HIV-1 RNA and lower semen bacterial concentrations, whereas insertive anal sex was associated with higher bacterial concentrations. Additional studies evaluating the relationship between semen bacteria, inflammation, mucosal immunity, and HIV-1 shedding are needed to understand implications for HIV-1 transmission.

  11. Microchip Module for Blood Sample Preparation and Nucleic Acid Amplification Reactions

    PubMed Central

    Yuen, Po Ki; Kricka, Larry J.; Fortina, Paolo; Panaro, Nicholas J.; Sakazume, Taku; Wilding, Peter

    2001-01-01

    A computer numerical control-machined plexiglas-based microchip module was designed and constructed for the integration of blood sample preparation and nucleic acid amplification reactions. The microchip module is comprised of a custom-made heater-cooler for thermal cycling, a series of 254 μm × 254 μm microchannels for transporting human whole blood and reagents in and out of an 8–9 μL dual-purpose (cell isolation and PCR) glass-silicon microchip. White blood cells were first isolated from a small volume of human whole blood (<3 μL) in an integrated cell isolation–PCR microchip containing a series of 3.5-μm feature-sized “weir-type” filters, formed by an etched silicon dam spanning the flow chamber. A genomic target, a region in the human coagulation Factor V gene (226-bp), was subsequently directly amplified by microchip-based PCR on DNA released from white blood cells isolated on the filter section of the microchip mounted onto the microchip module. The microchip module provides a convenient means to simplify nucleic acid analyses by integrating two key steps in genetic testing procedures, cell isolation and PCR and promises to be adaptable for additional types of integrated assays. PMID:11230164

  12. Immunosuppressant therapeutic drug monitoring by LC-MS/MS: workflow optimization through automated processing of whole blood samples.

    PubMed

    Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario

    2013-11-01

    Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.

  13. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    NASA Astrophysics Data System (ADS)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  14. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  15. Children's views on microneedle use as an alternative to blood sampling for patient monitoring.

    PubMed

    Mooney, Karen; McElnay, James C; Donnelly, Ryan F

    2014-10-01

    To explore children's views on microneedle use for this population, particularly as an alternative approach to blood sampling, in monitoring applications, and so, examine the acceptability of this approach to children. Focus groups were conducted with children (aged 10-14 years) in a range of schools across Northern Ireland. Convenience sampling was employed, i.e. children involved in a university-directed community-outreach project (Pharmacists in Schools) were recruited. A total of 86 children participated in 13 focus groups across seven schools in Northern Ireland. A widespread disapproval for blood sampling was evident, with pain, blood and traditional needle visualisation particularly unpopular aspects. In general, microneedles had greater visual acceptability and caused less fear. A patch-based design enabled minimal patient awareness of the monitoring procedure, with personalised designs, e.g. cartoon themes, favoured. Children's concerns included possible allergy and potential inaccuracies with this novel approach; however, many had confidence in the judgement of healthcare professionals if deeming this technique appropriate. They considered paediatric patient education critical for acceptance of this new approach and called for an alternative name, without any reference to 'needles'. The findings presented here support the development of blood-free, minimally invasive techniques and provide an initial indication of microneedle acceptability in children, particularly for monitoring purposes. A proactive response to these unique insights should enable microneedle array design to better meet the needs of this end-user group. Further work in this area is recommended to ascertain the perspectives of a purposive sample of children with chronic conditions who require regular monitoring. © 2013 Royal Pharmaceutical Society.

  16. The relationship between blood viscosity and blood pressure in a random sample of the population aged 55 to 74 years.

    PubMed

    Fowkes, F G; Lowe, G D; Rumley, A; Lennie, S E; Smith, F B; Donnan, P T

    1993-05-01

    Blood viscosity is elevated in hypertensive subjects, but the association of viscosity with arterial blood pressure in the general population, and the influence of social, lifestyle and disease characteristics on this association, are not established. In the Edinburgh Artery Study, 1592 men and women aged 55-74 years selected randomly from the general population attended a university clinic. A fasting blood sample was taken for the measurement of blood viscosity and its major determinants (haematocrit, plasma viscosity and fibrinogen). Systolic pressure was related univariately to blood viscosity (P < 0.001), plasma viscosity (P < 0.001) and plasma fibrinogen (P < 0.01), but the association with fibrinogen did not persist after adjusting for body mass index. Diastolic pressure was related univariately to blood viscosity (P < 0.001) and plasma viscosity (P < 0.001) and haematocrit (P < 0.001) but not to fibrinogen. The only difference between the sexes was that the association between blood viscosity and systolic pressure was confined to males. Blood viscosity was associated equally with systolic and diastolic pressures in males, and remained independently related on multivariate analysis adjusting for age, sex, body mass index, social class, smoking, alcohol intake, exercise, angina, HDL and non-HDL cholesterol, diabetes mellitus, plasma viscosity, fibrinogen, and haematocrit.

  17. Evaluation of a nested-PCR for mycobacterium tuberculosis detection in blood and urine samples.

    PubMed

    da Cruz, Heidi Lacerda Alves; de Albuquerque Montenegro, Rosana; de Araújo Lima, Juliana Falcão; da Rocha Poroca, Diogo; da Costa Lima, Juliana Figueirêdo; Maria Lapa Montenegro, Lílian; Crovella, Sergio; Charifker Schindler, Haiana

    2011-01-01

    The polymerase chain reaction (PCR) and its variations, such as the nested-PCR, have been described as promising techniques for rapid diagnosis of tuberculosis (TB). With the aim of evaluating the usefulness of a nested-PCR method on samples of blood and urine of patients suspected of tuberculosis we analyzed 192 clinical samples, using as a molecular target the insertion element IS6110 specific of M. tuberculosis genome. Nested-PCR method showed higher sensitivity in patients with extrapulmonary tuberculosis (47.8% and 52% in blood and urine) when compared to patients with the pulmonary form of the disease (sensitivity of 29% and 26.9% in blood and urine), regardless of the type of biological sample used. The nested-PCR is a rapid technique that, even if not showing a good sensitivity, should be considered as a helpful tool especially in the extrapulmonary cases or in cases where confirmatory diagnosis is quite difficult to be achieved by routine methods. The performance of PCR-based techniques should be considered and tested in future works on other types of biological specimens besides sputum, like blood and urine, readily obtainable in most cases. The improving of M. tuberculosis nested-PCR detection in TB affected patients will give the possibility of an earlier detection of bacilli thus interrupting the transmission chain of the disease.

  18. Transnational Terrorism in East Africa: A Qualitative and Quantitative Analysis of the Recent Rise in Kenyan Violence

    DTIC Science & Technology

    2014-06-01

    vibrant coastal beach tourism industry that is at odds with the locally dominant Islamic religion and culture; the perception that the country’s...other large scale cross-border attack by Al- Shabaab was the July 2010 twin bombing of a popular sports bar and restaurant in the Ugandan capital...Kenyan nationals from neighboring countries, as the majority of them frequently travel by road to and from Kenya for business, leisure, and tourism , 35

  19. Differences between blood donors and a population sample: implications for case-control studies.

    PubMed

    Golding, Jean; Northstone, Kate; Miller, Laura L; Davey Smith, George; Pembrey, Marcus

    2013-08-01

    Selecting appropriate controls for studies of genetic variation in case series is important. The two major candidates involve the use of blood donors or a random sample of the population. We compare and contrast the two different populations of controls for studies of genetic variation using data from parents enrolled in the Avon Longitudinal Study of Parents and Children (ALSPAC). In addition we compute different biases using a series of hypothetical assumptions. The study subjects who had been blood donors differed markedly from the general population in social, health-related, anthropometric, and personality-related variables. Using theoretical examples, we show that blood donors are a poor control group for non-genetic studies of diseases related to environmentally, behaviourally, or socially patterned exposures. However, we show that if blood donors are used as controls in genetic studies, these factors are unlikely to make a major difference in detecting true associations with relatively rare disorders (cumulative incidence through life of <10%). Nevertheless, for more common disorders, the reduction in accuracy resulting from the inclusion in any control population of individuals who have or will develop the disease in question can create a greater bias than can socially patterned factors. Information about the medical history of a control and the parents of the control (as a proxy for whether the control will develop the disease) is more important with regard to the choice of controls than whether the controls are a random population sample or blood donors.

  20. Barrier screens: a method to sample blood-fed and host-seeking exophilic mosquitoes

    PubMed Central

    2013-01-01

    Background Determining the proportion of blood meals on humans by outdoor-feeding and resting mosquitoes is challenging. This is largely due to the difficulty of finding an adequate and unbiased sample of resting, engorged mosquitoes to enable the identification of host blood meal sources. This is particularly difficult in the south-west Pacific countries of Indonesia, the Solomon Islands and Papua New Guinea where thick vegetation constitutes the primary resting sites for the exophilic mosquitoes that are the primary malaria and filariasis vectors. Methods Barrier screens of shade-cloth netting attached to bamboo poles were constructed between villages and likely areas where mosquitoes might seek blood meals or rest. Flying mosquitoes, obstructed by the barrier screens, would temporarily stop and could then be captured by aspiration at hourly intervals throughout the night. Results In the three countries where this method was evaluated, blood-fed females of Anopheles farauti, Anopheles bancroftii, Anopheles longirostris, Anopheles sundaicus, Anopheles vagus, Anopheles kochi, Anopheles annularis, Anopheles tessellatus, Culex vishnui, Culex quinquefasciatus and Mansonia spp were collected while resting on the barrier screens. In addition, female Anopheles punctulatus and Armigeres spp as well as male An. farauti, Cx. vishnui, Cx. quinquefasciatus and Aedes species were similarly captured. Conclusions Building barrier screens as temporary resting sites in areas where mosquitoes were likely to fly was an extremely time-effective method for collecting an unbiased representative sample of engorged mosquitoes for determining the human blood index. PMID:23379959

  1. Reducing the risk of fatal and disabling hypoglycaemia: a comparison of arterial blood sampling systems.

    PubMed

    Brennan, K A; Eapen, G; Turnbull, D

    2010-04-01

    In 2008, the National Patient Safety Agency (NPSA) published a report after 42 incidents and two deaths where glucose-containing flush solutions were attached to the arterial line. The molar concentration of 5% glucose is 277 mmol litre(-1). Only a tiny amount of sample contamination will lead to an artificially high glucose. As the NPSA sought a solution, a bench model was constructed to compare the performance of three open and three closed arterial line systems in limiting sample contamination. All arterial line systems were set up in a standard manner and pressurized to 300 mm Hg with 5% glucose used as the flush solution. This was connected to the 'radial artery' using an 18 G needle representing the radial cannula. The radial artery was simulated using a wide-bore extension set with 'blood' flow at 60 ml min(-1). Blood was simulated by the addition of red dye to Hartmann's solution. Increasing multiples of arterial line dead space were aspirated and discarded. Blood samples were then obtained and glucose concentration was measured. Significant glucose contamination (3 mmol litre(-1) +/-3.4) was detected in all open arterial line systems up to an aspiration volume of five times the dead space. No samples from the closed systems recorded glucose concentration >1 mmol litre(-1). Recommended minimal discard volumes are inadequate in the presence of glucose as the flush solution and can lead to high blood glucose readings, inappropriate insulin use, and iatrogenic neuroglycopaenia. Our study demonstrates that the closed-loop arterial sampling system could be the universal solution sought by the NPSA.

  2. Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters

    PubMed Central

    Lippi, Giuseppe; Cervellin, Gianfranco; Mattiuzzi, Camilla

    2013-01-01

    Background: A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. Materials and methods: We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode. Results: Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40). Conclusions: Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration. PMID:23894864

  3. Behavior of optical properties of coagulated blood sample at 633 nm wavelength

    NASA Astrophysics Data System (ADS)

    Morales Cruzado, Beatriz; Vázquez y Montiel, Sergio; Delgado Atencio, José Alberto

    2011-03-01

    Determination of tissue optical parameters is fundamental for application of light in either diagnostics or therapeutical procedures. However, in samples of biological tissue in vitro, the optical properties are modified by cellular death or cellular agglomeration that can not be avoided. This phenomena change the propagation of light within the biological sample. Optical properties of human blood tissue were investigated in vitro at 633 nm using an optical setup that includes a double integrating sphere system. We measure the diffuse transmittance and diffuse reflectance of the blood sample and compare these physical properties with those obtained by Monte Carlo Multi-Layered (MCML). The extraction of the optical parameters: absorption coefficient μa, scattering coefficient μs and anisotropic factor g from the measurements were carried out using a Genetic Algorithm, in which the search procedure is based in the evolution of a population due to selection of the best individual, evaluated by a function that compares the diffuse transmittance and diffuse reflectance of those individuals with the experimental ones. The algorithm converges rapidly to the best individual, extracting the optical parameters of the sample. We compare our results with those obtained by using other retrieve procedures. We found that the scattering coefficient and the anisotropic factor change dramatically due to the formation of clusters.

  4. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    PubMed

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: <45, ~70, and ≥150 mmHg. For each system, five consecutive measurements on each sample aliquot were performed using the same test strip lot. Relative differences between the mean BG results at pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 <45 and ≥150 mmHg were calculated. For all tested GOx systems, mean relative differences in the BG measurement results were between 6.1% and 22.6% at pO2 <45 mmHg and between -7.9% and -14.9% at pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p < .0001). The GDH system showed mean relative differences of -1.0% and -0.4% at pO2 values <45 and ≥150 mmHg, respectively, which were not significant. These data suggest that capillary blood pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. © 2013 Diabetes Technology Society.

  5. Discrimination of lymphoma using laser-induced breakdown spectroscopy conducted on whole blood samples

    PubMed Central

    Chen, Xue; Li, Xiaohui; Yang, Sibo; Yu, Xin; Liu, Aichun

    2018-01-01

    Lymphoma is a significant cancer that affects the human lymphatic and hematopoietic systems. In this work, discrimination of lymphoma using laser-induced breakdown spectroscopy (LIBS) conducted on whole blood samples is presented. The whole blood samples collected from lymphoma patients and healthy controls are deposited onto standard quantitative filter papers and ablated with a 1064 nm Q-switched Nd:YAG laser. 16 atomic and ionic emission lines of calcium (Ca), iron (Fe), magnesium (Mg), potassium (K) and sodium (Na) are selected to discriminate the cancer disease. Chemometric methods, including principal component analysis (PCA), linear discriminant analysis (LDA) classification, and k nearest neighbor (kNN) classification are used to build the discrimination models. Both LDA and kNN models have achieved very good discrimination performances for lymphoma, with an accuracy of over 99.7%, a sensitivity of over 0.996, and a specificity of over 0.997. These results demonstrate that the whole-blood-based LIBS technique in combination with chemometric methods can serve as a fast, less invasive, and accurate method for detection and discrimination of human malignancies. PMID:29541503

  6. Dose Responses of Ibuprofen In Vitro on Platelet Aggregation and Coagulation in Human and Pig Blood Samples.

    PubMed

    Martini, Wenjun Z; Rodriguez, Cassandra M; Deguzman, Rodolfo; Guerra, Jessica B; Martin, Angela K; Pusateri, Anthony E; Cap, Andrew P; Dubick, Michael A

    2016-05-01

    Ibuprofen is commonly used by warfighters in the deployed environment. This study investigated its dose effects on in vitro coagulation in human and pig blood. Blood samples were collected from 6 normal volunteers and 6 healthy pigs and processed to make platelet-adjusted samples (100 × 10(3)/μL, common transfusion trigger in trauma). Ibuprofen was added to the samples at concentrations of 0 μg/mL (control), the concentration from the highest recommended oral dose (163 μg/mL, 1×), and 2×, 4×, 8×, 10×, 12×, 16×, and 20×. Platelet aggregation by Chrono-Log aggregometer and coagulation by rotational thrombelastogram (Rotem) were assessed at 15 minutes after the addition of ibuprofen. A robust inhibition of ibuprofen on arachidonic acid-induced platelet aggregation was observed at all doses tested in human or pig blood. Collagen-stimulated platelet aggregation was inhibited starting at 1× in human blood and 4× in pig blood. Rotem measurements were similarly compromised in pig and human blood starting at 16×, except clot formation time was prolonged at 1× in human blood (all p < 0.05). Ibuprofen inhibited platelet aggregation at recommended doses, and compromised coagulation at higher doses. Human blood was more sensitive to ibuprofen inhibition. Further effort is needed to investigate ibuprofen dose responses on coagulation in vivo. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  7. Development and validation of a dried blood spot-HPLC assay for the determination of metronidazole in neonatal whole blood samples.

    PubMed

    Suyagh, Maysa Faisal; Iheagwaram, Godwill; Kole, Prashant Laxman; Millership, Jeff; Collier, Paul; Halliday, Henry; McElnay, James C

    2010-05-01

    A selective and sensitive high-performance liquid chromatography method with UV detection for the determination of metronidazole in dried blood spots (DBS) has been developed and validated. DBS samples [spiked or patient samples] were prepared by applying blood (30 microL) to Guthrie cards. Discs (6 mm diameter) were punched from the cards and extracted using water containing the internal standard, tinidazole. The extracted sample was chromatographed without further treatment using a reversed phase system involving a Symmetry(R) C18 (5 microm, 3.9 x 150 mm) preceded by a Symmetry(R) guard column of matching chemistry and a detection wavelength of 317 nm. The mobile phase comprised acetonitrile/0.01 M phosphate solution (KH(2)PO(4)), pH 4.7, 15:85, v/v, with a flow rate of 1 mL/min. The calibration was linear over the range 2.5-50 mg/mL. The limits of detection and quantification were 0.6 and 1.8 microg/mL, respectively. The method has been applied to the determination of 203 DBS samples from neonatal patients for a phamacokinetic/pharmacodynamic study.

  8. Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP-MS.

    PubMed

    Heitland, Peter; Köster, Helmut D

    2006-01-01

    The trace elements Ag, As, Au, B, Ba, Be, Bi, Cd, Ce, Co, Cs, Cu, Ga, Hf, Hg, In, La, Mn, Mo, Ni, Pb, Pd, Rb, Rh, Ru, Sb, Se, Sn, Sr, Te, Th, Tl, U, V, W, Y and Zr were determined in 130 human blood samples from occupationally non-exposed volunteers living in the greater area of Bremen in northern Germany. The blood samples were collected in lithium heparin monovettes developed for trace metal determination and were analysed by inductively coupled plasma mass spectrometry (ICP-MS) with an octopole-based collision/reaction cell. For sample introduction into the ICP, the blood samples were diluted 1/10 (V/V) with a 0.1% Triton-X-100 and 0.5% (V/V) ammonia solution. The method validation of our developed routine method is described for all 37 elements and results about internal and external quality assurance are discussed. Information on exposure conditions of all human subjects were collected by questionnaire-based interviews, including smoking habits, seafood consumption and the type of dental alloys in the teeth. Mean values, geometric mean values, ranges and selected percentiles of all elemental concentrations in human blood are presented, which helps toxicologists and clinical chemists planning research about exposition to metals and health effects caused by exposition to metals.

  9. Preparation of serum and plasma samples for determination of tricyclic antidepressants: effects of blood collection tubes and storage.

    PubMed

    Nyberg, G; Mårtensson, E

    1986-01-01

    The effects were tested of eight common types of blood collection tubes and two types of "plasma separators" on the stability of the tricyclic antidepressants amitriptyline, imipramine, clomipramine, and their monodemethylated metabolites in venous blood samples. Although EDTA-containing Venoject lavender and Vacutainer lavender tubes seemed to give the most stable plasma samples, and Venoject red the most stable serum samples, the differences were too small to have practical consequences. Vacutainer royal blue collection tubes gave significant losses of greater than 20% of some of the substances. The tubes with serum separator gel or filter proved unsuitable, since they were responsible for losses of greater than 40%. The losses were not caused by redistribution between blood cells and plasma but occurred mainly as a result of contact between the contents and the caps of the tubes. Experiments with freezing, thawing, and storage of samples showed that freshly sampled blood could be stored at room temperature for 24 h in Venoject green tubes without significant losses. Serum samples could be stored at refrigerator temperature for 4 weeks without important losses. Freezing, thawing, and storage at -20 degrees C did not influence the serum or plasma concentrations.

  10. Evaluation of dry blood spot technique for quantification of an Anti-CD20 monoclonal antibody drug in human blood samples.

    PubMed

    Lin, Yong-Qing; Zhang, Yilu; Li, Connie; Li, Louis; Zhang, Kelley; Li, Shawn

    2012-01-01

    To evaluate the dried blood spot (DBS) technique in ELISA quantification of larger biomolecular drugs, an anti-CD20 monoclonal antibody drug was used as an example. A method for the quantification of the anti-CD20 drug in human DBS was developed and validated. The drug standard and quality control samples prepared in fresh human blood were spotted on DBS cards and then extracted. A luminescent ELISA was used for quantification of the drug from DBS samples. The assay range of the anti-CD20 drug standards in DBS was 100-2500ng/mL. The intra-assay precision (%CV) ranged from 0.4% to 10.1%, and the accuracy (%Recovery) ranged from 77.9% to 113.9%. The inter assay precision (%CV) ranged from 5.9% to 17.4%, and the accuracy ranged from 81.5% to 110.5%. The DBS samples diluted 500 and 50-fold yielded recovery of 88.7% and 90.7%, respectively. The preparation of DBS in higher and lower hematocrit (53% and 35%) conditions did not affect the recovery of the drug. Furthermore, the storage stability of the anti-CD20 drug on DBS cards was tested at various conditions. It was found that the anti-CD20 drug was stable for one week in DBS stored at room temperature. However, it was determined that the stability was compro]mised in DBS stored at high humidity, high temperature (55°C), and exposed to direct daylight for a week, as well as for samples stored at room temperature and high humidity conditions for a month. Stability did not change significantly in samples that underwent 3 freeze/thaw cycles. Our results demonstrated a successful use of DBS technique in ELISA quantification of an anti-CD20 monoclonal antibody drug in human blood. The stability data provides information regarding sample storage and shipping for future clinical studies. It is, therefore, concluded that the DBS technique is applicable in the quantification of other large biomolecule drugs or biomarkers. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    PubMed

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. School Based Factors Affecting Learning of Kenyan Sign Language in Primary Schools for Hearing Impaired in Embu and Isiolo Counties, Kenya

    ERIC Educational Resources Information Center

    Rwaimba, Samuel Muthomi

    2016-01-01

    This was a descriptive survey study design which sought to establish the school based factors that affect the learning of Kenyan Sign Language in primary schools for learners with hearing impairment in Embu and Isiolo counties in Kenya. The target population was all teachers teaching in primary schools for learners with hearing impairment in the…

  13. Rapid Diagnosis of Staphylococcal Catheter-Related Bacteraemia in Direct Blood Samples by Real-Time PCR

    PubMed Central

    Soto, Marcelo; Sampietro-Colom, Laura; Soriano, Alex; Alvarez-Martínez, Míriam José; Almela, Manel; Marco, Francesc; Arjona, Ruth; Cobos-Trigueros, Nazaret; Morata, Laura; Mensa, José; Martínez, José Antonio; Mira, Aurea

    2016-01-01

    Catheter-related bacteremia (CRB) is an important cause of morbidity and mortality among hospitalized patients, being staphylococci the main etiologic agents. The objective of this study was to assess the use of a PCR-based assay for detection of staphylococci directly from blood obtained through the catheter to diagnose CRB caused by these microorganisms and to perform a cost-effectiveness analysis. A total of 92 patients with suspected CRB were included in the study. Samples were obtained through the catheter. Paired blood cultures were processed by standard culture methods and 4 ml blood samples were processed by GeneXpert-MRSA assay for the detection of methicillin-susceptible (MSSA) or methicillin-resistant (MRSA) Staphylococcus aureus, and methicillin-resistant coagulase-negative staphylococci (MR-CoNS). Sixteen CRB caused by staphylococci were diagnosed among 92 suspected patients. GeneXpert detected 14 out of 16 cases (87.5%), including 4 MSSA and 10 MR-CoNS in approximately 1 hour after specimen receipt. The sensitivity and specificity of GeneXpert were 87.5% (CI 95%: 60.4–97.8) and 92.1% (CI 95%: 83–96.7), respectively, compared with standard culture methods. The sensitivity of GeneXpert for S. aureus was 100%. Regarding a cost-effectiveness analysis, the incremental cost of using GeneXpert was of 31.1€ per patient while the incremental cost-effectiveness ratio of GeneXpert compared with blood culture alones was about 180€ per life year gained. In conclusion, GeneXpert can be used directly with blood samples obtained through infected catheters to detect S. aureus and MR-CoNS in approximately 1h after sampling. In addition, it is cost-effective especially in areas with high prevalence of staphylococcal CRB. PMID:27571200

  14. Assessment of erythrocyte aggregation in whole blood samples by light backscattering: clinical applications

    NASA Astrophysics Data System (ADS)

    Priezzhev, Alexander V.; Firsov, Nikolai N.; Vyshlova, Marina G.; Lademann, Juergen; Richter, Heike; Kiesewetter, Holger; Mueller, Gerhard J.

    1999-05-01

    We report on the results of a collaborative effort made in the field of optical diagnostics of whole blood samples to study the ability of red blood cells to aggregate in a Couette chamber. We studied a possibility to quantitatively measure this ability as a function of the physiological state of blood donors. The aggregometer designed by the Russian coauthors of this paper and described in their earlier publications (see e.g. Proc SPIE 1884, 2100, 2678, 2982) was extensively used in the experiments performed in the Rheumatology Institute in Moscow and in the Charite Clinic in Berlin. The following parameters were measured: two characteristic times of RBC aggregation and the average spontaneous aggregation rate in the state of stasis, the average hydrodynamic strength of all aggregates and that of the largest aggregates. Different algorithms of the remission signal processing for the quantitative evaluation of the above parameters were compared. Reproducible alterations of the parameters from their normal values were obtained for blood samples from individuals suffering auto-immune disease and diabetes. Statistical data is reported proving high efficiency of the technique for the diagnostics of rheological disorders. Basing on these data the quantitative criteria of the heaviness of hemorheological state of the patients are proposed that are important for choosing specific therapies for which the patient is minimally resistant.

  15. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-09-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  16. Semen Bacterial Concentrations and HIV-1 RNA Shedding Among HIV-1–Seropositive Kenyan Men

    PubMed Central

    Srinivasan, Sujatha; Huang, Dandi; Ko, Daisy L.; Sanders, Eduard J.; Peshu, Norbert M.; Krieger, John N.; Muller, Charles H.; Coombs, Robert W.; Fredricks, David N.; Graham, Susan M.

    2017-01-01

    Introduction: HIV-1 is transmitted through semen from men to their sexual partners. Genital infections can increase HIV-1 RNA shedding in semen, but shedding also occurs in the absence of typical pathogens. We hypothesized that higher bacterial concentrations in semen would be associated with higher HIV-1 RNA levels. Methods: We analyzed semen samples from 42 HIV-1–seropositive Kenyan men using quantitative polymerase chain reaction (PCR) to assess bacterial concentrations and real-time PCR to measure HIV-1 RNA levels. Generalized estimation equations were used to evaluate associations between these 2 measures. Broad-range 16S rRNA gene PCR with pyrosequencing was performed on a subset of 13 samples to assess bacterial community composition. Results: Bacteria were detected in 96.6% of 88 samples by quantitative PCR. Semen bacterial concentration and HIV-1 RNA levels were correlated 0.30 (P = 0.01). The association between bacterial concentration and HIV-1 RNA detection was not significant after adjustment for antiretroviral therapy (ART) (adjusted odds ratio: 1.27, 95% CI: 0.84 to 1.91). Factors associated with semen bacterial concentration included insertive anal sex (adjusted beta 0.92, 95% CI: 0.12 to 1.73) and ART use (adjusted beta: −0.77, 95% CI: −1.50 to 0.04). Among 13 samples with pyrosequencing data, Corynebacterium spp., Staphylococcus spp., and Streptococcus spp. were most frequently detected. Conclusion: Most of these HIV-1–infected men had bacteria in their semen. ART use was associated with undetectable semen HIV-1 RNA and lower semen bacterial concentrations, whereas insertive anal sex was associated with higher bacterial concentrations. Additional studies evaluating the relationship between semen bacteria, inflammation, mucosal immunity, and HIV-1 shedding are needed to understand implications for HIV-1 transmission. PMID:27861240

  17. Changing Malaria Prevalence on the Kenyan Coast since 1974: Climate, Drugs and Vector Control

    PubMed Central

    Snow, Robert W.; Kibuchi, Eliud; Karuri, Stella W.; Sang, Gilbert; Gitonga, Caroline W.; Mwandawiro, Charles; Bejon, Philip; Noor, Abdisalan M.

    2015-01-01

    Background Progress toward reducing the malaria burden in Africa has been measured, or modeled, using datasets with relatively short time-windows. These restricted temporal analyses may miss the wider context of longer-term cycles of malaria risk and hence may lead to incorrect inferences regarding the impact of intervention. Methods 1147 age-corrected Plasmodium falciparum parasite prevalence (PfPR2-10) surveys among rural communities along the Kenyan coast were assembled from 1974 to 2014. A Bayesian conditional autoregressive generalized linear mixed model was used to interpolate to 279 small areas for each of the 41 years since 1974. Best-fit polynomial splined curves of changing PfPR2-10 were compared to a sequence of plausible explanatory variables related to rainfall, drug resistance and insecticide-treated bed net (ITN) use. Results P. falciparum parasite prevalence initially rose from 1974 to 1987, dipped in 1991–92 but remained high until 1998. From 1998 onwards prevalence began to decline until 2011, then began to rise through to 2014. This major decline occurred before ITNs were widely distributed and variation in rainfall coincided with some, but not all, short-term transmission cycles. Emerging resistance to chloroquine and introduction of sulfadoxine/pyrimethamine provided plausible explanations for the rise and fall of malaria transmission along the Kenyan coast. Conclusions Progress towards elimination might not be as predictable as we would like, where natural and extrinsic cycles of transmission confound evaluations of the effect of interventions. Deciding where a country lies on an elimination pathway requires careful empiric observation of the long-term epidemiology of malaria transmission. PMID:26107772

  18. Perceptions of emergency care in Kenyan communities lacking access to formalised emergency medical systems: a qualitative study

    PubMed Central

    Broccoli, Morgan C; Calvello, Emilie J B; Skog, Alexander P; Wachira, Benjamin; Wallis, Lee A

    2015-01-01

    Objectives We undertook this study in Kenya to understand the community's emergency care needs and barriers they face when trying to access care, and to seek community members’ thoughts regarding high impact solutions to expand access to essential emergency services. Design We used a qualitative research methodology to conduct 59 focus groups with 528 total Kenyan community member participants. Data were coded, aggregated and analysed using the content analysis approach. Setting Participants were uniformly selected from all eight of the historical Kenyan provinces (Central, Coast, Eastern, Nairobi, North Eastern, Nyanza, Rift Valley and Western), with equal rural and urban community representation. Results Socioeconomic and cultural factors play a major role both in seeking and reaching emergency care. Community members in Kenya experience a wide range of medical emergencies, and seem to understand their time-critical nature. They rely on one another for assistance in the face of substantial barriers to care—a lack of: system structure, resources, transportation, trained healthcare providers and initial care at the scene. Conclusions Access to emergency care in Kenya can be improved by encouraging recognition and initial treatment of emergent illness in the community, strengthening the pre-hospital care system, improving emergency care delivery at health facilities and creating new policies at a national level. These community-generated solutions likely have a wider applicability in the region. PMID:26586324

  19. On the improvement of blood sample collection at clinical laboratories

    PubMed Central

    2014-01-01

    Background Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. Methods A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. Results The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. Conclusions The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem. PMID:24406140

  20. Social scripts and stark realities: Kenyan adolescents' abortion discourse.

    PubMed

    Mitchell, Ellen M H; Halpern, Carolyn Tucker; Kamathi, Eva Muthuuri; Owino, Shirley

    2006-01-01

    This study explores students' narratives and discourses about adolescent pregnancy and abortion elicited via internet-based open-ended questions posed in response to a cartoon vignette. We report on content analysis of recommendations and strategies for how to manage the unplanned pregnancy of a fictional young couple and in their own personal lives. The responses of 614 young people were analysed. Strategies vary widely. They include giving birth, adoption, running away, abortion, denial, and postponement until discovery. Young people were also queried about unplanned pregnancy resolution among their peers. Discourse analysis reveals competing social scripts on abortion. Florid condemnation of abortion acts in the hypothetical cases contrasts with more frank and sober description of peers' real life abortion behaviour. Students' language is compared with that found in official curricula. The rhetorical devices, moralizing social scripts and dubious health claims about abortion in students' online narratives mirror the tenor and content of their academic curricula as well as Kenyan media presentation of the issue. The need for factual information, dispassionate dialogue and improved contraceptive access is considerable.

  1. Gender scripts and unwanted pregnancy among urban Kenyan women.

    PubMed

    Izugbara, Chimaraoke O; Ochako, Rhoune; Izugbara, Chibuogwu

    2011-10-01

    Women's lived experiences and lay accounts of unwanted pregnancy remain poorly interrogated. We investigated portrayals of unwanted pregnancy using narrative data gathered from 80 women in Nairobi, Kenya. Unwanted pregnancy had a diversity of significance for the women. Pregnancies were not simply unwanted because they occurred when women became pregnant without wanting to. Rather, pregnancies were considered unwanted largely because they had occurred in contexts that did not reinforce socially-sanctioned notions of motherhood and 'proper' procreation and/or revealed women's use of their sexuality in ways deemed culturally-inappropriate. Kenyan women's invocation of femininity scripts to explain unwanted pregnancy; the centrality of gender in everyday life in contemporary Kenya; women's and girls' poor access to effective family planning services; growing female poverty; and Kenya's restrictive abortion policy imply that unwanted pregnancy and its consequences will persist in the country. Addressing unwanted pregnancy and its consequences requires making accessible quality contraceptive and abortion services as well as sexuality information. It also calls for providers who understand the socio-cultural norms that circumscribe fertility and reproductive behaviours.

  2. Comparative value of blood and skin samples for diagnosis of spotted fever group rickettsial infection in model animals.

    PubMed

    Levin, Michael L; Snellgrove, Alyssa N; Zemtsova, Galina E

    2016-07-01

    The definitive diagnosis of spotted fever group (SFG) rickettsioses in humans is challenging due to the retrospective nature and cross reactivity of the serological methods and the absence of reliable and consistent samples for molecular diagnostics. Existing data indicate the transient character of bacteremia in experimentally infected animals. The ability of arthropod vectors to acquire rickettsial infection from the laboratory animals in the absence of systemic infection and known tropism of rickettsial agents to endothelial cells of peripheral blood vessels underline the importance of local infection and consequently the diagnostic potential of skin samples. In order to evaluate the diagnostic sensitivity of rickettsial DNA detection in blood and skin samples, we compared results of PCR testing in parallel samples collected from model laboratory animals infected with Rickettsia rickettsii, Rickettsia parkeri and Rickettsia slovaca-like agent at different time points after infection. Skin samples were collected from ears - away from the site of tick placement and without eschars. Overall, testing of skin samples resulted in a higher proportion of positive results than testing of blood samples. Presented data from model animals demonstrates that testing of skin samples from sites of rickettsial proliferation can provide definitive molecular diagnosis of up to 60-70% of tick-borne SFG rickettsial infections during the acute stage of illness. Detection of pathogen DNA in cutaneous samples is a valuable alternative to blood-PCR at least in model animals. Published by Elsevier GmbH.

  3. Effect of postmortem sampling technique on the clinical significance of autopsy blood cultures.

    PubMed

    Hove, M; Pencil, S D

    1998-02-01

    Our objective was to investigate the value of postmortem autopsy blood cultures performed with an iodine-subclavian technique relative to the classical method of atrial heat searing and antemortem blood cultures. The study consisted of a prospective autopsy series with each case serving as its own control relative to subsequent testing, and a retrospective survey of patients coming to autopsy who had both autopsy blood cultures and premortem blood cultures. A busy academic autopsy service (600 cases per year) at University of Texas Medical Branch Hospitals, Galveston, Texas, served as the setting for this work. The incidence of non-clinically relevant (false-positive) culture results were compared using different methods for collecting blood samples in a prospective series of 38 adult autopsy specimens. One hundred eleven adult autopsy specimens in which both postmortem and antemortem blood cultures were obtained were studied retrospectively. For both studies, positive culture results were scored as either clinically relevant or false positives based on analysis of the autopsy findings and the clinical summary. The rate of false-positive culture results obtained by an iodine-subclavian technique from blood drawn soon after death were statistically significantly lower (13%) than using the classical method of obtaining blood through the atrium after heat searing at the time of the autopsy (34%) in the same set of autopsy subjects. When autopsy results were compared with subjects' antemortem blood culture results, there was no significant difference in the rate of non-clinically relevant culture results in a paired retrospective series of antemortem blood cultures and postmortem blood cultures using the iodine-subclavian postmortem method (11.7% v 13.5%). The results indicate that autopsy blood cultures obtained using the iodine-subclavian technique have reliability equivalent to that of antemortem blood cultures.

  4. Perchlorate and iodide in whole blood samples from infants, children, and adults in Nanchang, China.

    PubMed

    Zhang, Tao; Wu, Qian; Sun, Hong Wen; Rao, Jia; Kannan, Kurunthachalam

    2010-09-15

    Perchlorate, ClO(4)(-), interferes with iodide (I(-)) uptake by the sodium-iodide symporter (NIS) and thereby affects thyroid hormone production in the body. Studies have reported human exposures to perchlorate based on measurements in urine, but little is known about the levels in blood. In this study, we determined concentrations of perchlorate, iodide, and other anions (e.g., chlorate [ClO(3)(-)], bromate [BrO(3)(-)], bromide [Br(-)]) in 131 whole blood samples collected from Chinese donors aged 0.4 to 90 yr, in Nanchang, China. Perchlorate, iodide, and bromide were detected in all of the samples analyzed, whereas chlorate was found in only 27% of the samples and bromate was found in only 2%. The mean (range) concentrations of perchlorate, iodide, and bromide were 2.68 (0.51-10.5), 42.6 (1.58-812), and 2120 (1050-4850) ng/mL, respectively. Perchlorate levels in blood from Nanchang adults were 10-fold greater than levels that have been previously reported for U.S. adults. The iodide/perchlorate molar ratio ranged from 3.05 to 15.3 for all age groups, and the ratio increased with age (r = 0.732, p < 0.01). Perchlorate and bromide concentrations decreased significantly with age, whereas iodide concentrations increased with age. No significant gender-related differences in blood perchlorate, iodide, or bromide levels were found. A significant negative correlation was found between the concentrations of perchlorate and iodide in blood. Exposure doses of perchlorate were estimated for infants, toddlers, children, adolescents, and adults based on the measured concentrations in blood, using a simple pharmacokinetic model. The mean exposure doses of perchlorate for our age groups ranged from 1.12 (adults) to 2.22 μg/kg bw/day (infants), values higher than the United States Environmental Protection Agency's (USEPA) reference dose (RfD: 0.7 μg/kg bw/day). This is the first study on perchlorate and iodide levels in whole blood from infants, toddlers, children, adolescents

  5. Around the Table: Food Insecurity, Socioeconomic Status, and Instrumental Social Support among Women Living in a Rural Kenyan Island Community.

    PubMed

    Nagata, Jason M; Fiorella, Kathryn J; Salmen, Charles R; Hickey, Matthew D; Mattah, Brian; Magerenge, Richard; Milner, Erin M; Weiser, Sheri D; Bukusi, Elizabeth A; Cohen, Craig R

    2015-01-01

    The objective of this study was to investigate the relationship among socioeconomic status, social support, and food insecurity in a rural Kenyan island community. A cross-sectional random sample of 111 female heads of households representing 583 household members were surveyed in Mfangano Island, Kenya from August to October 2010 using adaptations of the Household Food Insecurity Access Scale and the Medical Outcomes Study Social Support Survey. In multiple linear regression models, less instrumental social support, defined as concrete direct ways people help others (B = -0.81; 95% confidence interval [CI] -1.45 to -0.17), and decreased ownership scale based on owning material assets (B = -2.93; 95% CI -4.99 to -0.86) were significantly associated with increased food insecurity, controlling for age, education, marital status, and household size. Social support interventions geared at group capacity and resilience may be crucial adjuncts to improve and maintain the long term food security and health of persons living in low-resource regions.

  6. A rapid and efficient DNA extraction protocol from fresh and frozen human blood samples.

    PubMed

    Guha, Pokhraj; Das, Avishek; Dutta, Somit; Chaudhuri, Tapas Kumar

    2018-01-01

    Different methods available for extraction of human genomic DNA suffer from one or more drawbacks including low yield, compromised quality, cost, time consumption, use of toxic organic solvents, and many more. Herein, we aimed to develop a method to extract DNA from 500 μL of fresh or frozen human blood. Five hundred microliters of fresh and frozen human blood samples were used for standardization of the extraction procedure. Absorbance at 260 and 280 nm, respectively, (A 260 /A 280 ) were estimated to check the quality and quantity of the extracted DNA sample. Qualitative assessment of the extracted DNA was checked by Polymerase Chain reaction and double digestion of the DNA sample. Our protocol resulted in average yield of 22±2.97 μg and 20.5±3.97 μg from 500 μL of fresh and frozen blood, respectively, which were comparable to many reference protocols and kits. Besides yielding bulk amount of DNA, our protocol is rapid, economical, and avoids toxic organic solvents such as Phenol. Due to unaffected quality, the DNA is suitable for downstream applications. The protocol may also be useful for pursuing basic molecular researches in laboratories having limited funds. © 2017 Wiley Periodicals, Inc.

  7. T2 Magnetic Resonance Assay-Based Direct Detection of Three Lyme Disease-Related Borrelia Species in Whole-Blood Samples

    PubMed Central

    Giese, Heidi; Bandoski-Gralinski, Cheryl; Townsend, Jessica; Jacobson, Beck E.; Shivers, Robert; Schotthoefer, Anna M.; Fritsche, Thomas R.; Green, Clayton; Callister, Steven M.; Branda, John A.

    2017-01-01

    ABSTRACT In early Lyme disease (LD), serologic testing is insensitive and seroreactivity may reflect active or past infection. In this study, we evaluated a novel assay for the direct detection of three species of Borrelia spirochetes in whole blood. The T2 magnetic resonance (T2MR) assay platform was used to amplify Borrelia DNA released from intact spirochetes and to detect amplicon. Analytical sensitivity was determined from blood spiked with known concentrations of spirochetes, and the assay's limit of detection was found to be in the single-cell-per-milliliter range: 5 cells/ml for B. afzelii and 8 cells/ml for Borrelia burgdorferi and Borrelia garinii. Clinical samples (n = 66) from confirmed or suspected early LD patients were also analyzed. B. burgdorferi was detected using T2MR in 2/2 (100%) of blood samples from patients with confirmed early LD, based on the presence of erythema migrans and documentation of seroconversion or a positive real-time blood PCR. T2MR detected B. burgdorferi in blood samples from 17/54 (31%) of patients with probable LD, based on the presence of erythema migrans without documented seroconversion or of documented seroconversion in patients with a compatible clinical syndrome but without erythema migrans. Out of 21 clinical samples tested by real-time PCR, only 1 was positive and 13 were negative with agreement with T2MR. An additional 7 samples that were negative by real-time PCR were positive with T2MR. Therefore, T2MR enables a low limit of detection (LoD) for Borrelia spp. in whole blood samples and is able to detect B. burgdorferi in clinical samples. PMID:28566314

  8. Detection of Cytomegalovirus (CMV) DNA in EDTA Whole-Blood Samples: Evaluation of the Quantitative artus CMV LightCycler PCR Kit in Conjunction with Automated Sample Preparation▿

    PubMed Central

    Michelin, Birgit D. A.; Hadžisejdić, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blaženka; Marth, Egon; Kessler, Harald H.

    2008-01-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within ±0.5 log10 unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay. PMID:18272703

  9. Detection of cytomegalovirus (CMV) DNA in EDTA whole-blood samples: evaluation of the quantitative artus CMV LightCycler PCR kit in conjunction with automated sample preparation.

    PubMed

    Michelin, Birgit D A; Hadzisejdic, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blazenka; Marth, Egon; Kessler, Harald H

    2008-04-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.

  10. Biomonitoring of 33 Elements in Blood and Urine Samples from Coastal Populations in Sanmen County of Zhejiang Province.

    PubMed

    Zhang, Su-jing; Luo, Ru-xin; Ma, Dong; Zhuo, Xian-yi

    2016-04-01

    To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.

  11. Diagnosis of Carrion’s Disease by Direct Blood PCR in Thin Blood Smear Negative Samples

    PubMed Central

    Tinco Valdez, Carmen; Pons, Maria J.; del Valle, Luis J.; Oré, Verónica Casabona; Michelena, Denisse Champin; Mayra, Jorge Bazán; Gavidea, Víctor Zavaleta; Vargas, Martha; Ruiz, Joaquim

    2014-01-01

    Bartonella bacilliformis is the etiologic agent of Carrion's disease. This disease has two well established phases, the most relevant being the so called Oroya Fever, in which B. bacilliformis infect the erythrocytes resulting in severe anemia and transient immunosuppression, with a high lethality in the absence of adequate antibiotic treatment. The presence of B. bacilliformis was studied in 113 blood samples suspected of Carrion’s disease based on clinical criteria, despite the absence of a positive thin blood smear, by two different PCR techniques (using Bartonella-specific and universal 16S rRNA gene primers), and by bacterial culture. The specific 16S rRNA gene primers revealed the presence of 21 B. bacilliformis and 1 Bartonella elizabethae, while universal primers showed both the presence of 3 coinfections in which a concomitant pathogen was detected plus Bartonella, in addition to the presence of infections by other microorganisms such as Agrobacterium or Bacillus firmus. These data support the need to implement molecular tools to diagnose Carrion’s disease. PMID:24651298

  12. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    PubMed

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  13. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed Central

    Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.

    2016-01-01

    Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719

  14. Human Milk Oligosaccharides and Lewis Blood Group: Individual High-Throughput Sample Profiling to Enhance Conclusions From Functional Studies12

    PubMed Central

    Blank, Dennis; Dotz, Viktoria; Geyer, Rudolf; Kunz, Clemens

    2012-01-01

    Human milk oligosaccharides (HMO) are discussed to play a crucial role in an infant’s development. Lewis blood group epitopes, in particular, seem to remarkably contribute to the beneficial effects of HMO. In this regard, large-scale functional human studies could provide evidence of the variety of results from in vitro investigations, although increasing the amount and complexity of sample and data handling. Therefore, reliable screening approaches are needed. To predict the oligosaccharide pattern in milk, the routine serological Lewis blood group typing of blood samples can be applied due to the close relationship between the biosynthesis of HMO and the Lewis antigens on erythrocytes. However, the actual HMO profile of the individual samples does not necessarily correspond to the serological determinations. This review demonstrates the capabilities of merging the traditional serological Lewis blood group typing with the additional information provided by the comprehensive elucidation of individual HMO patterns by means of state-of-the-art analytics. Deduced from the association of the suggested HMO biosynthesis with the Lewis blood group, the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry profiles of oligosaccharides in individual milk samples exemplify the advantages and the limitations of sample assignment to distinct groups. PMID:22585923

  15. Evaluation of a simple method for storage of blood samples that enables isolation of circulating tumor cells 96 h after sample collection.

    PubMed

    Apostolou, Panagiotis; Ntanovasilis, Dimitrios-Athanasios; Papasotiriou, Ioannis

    2017-12-01

    Minimizing the effects of transportation on the properties of biological material is a major challenge for the scientific community. The viability of cells is important in cases where their study is urgent for evaluation of treatment response or for the study of cancer progression. Circulating tumor cells (CTCs) constitute a cell subpopulation with great importance for oncologists, because of their prognostic value. Detection and isolation of CTCs from blood samples is a routine activity in many laboratories, but concerns exist with regard to the maintenance of the cells during transportation. In this study, experiments were conducted to determine the stability of gene and protein expression in CTCs over a period of 96 h. Blood samples collected from healthy individuals and patients with cancer were each divided into five aliquots, which were stored at 2-8 °C and analyzed after 0, 24, 48, 72 and 96 h of storage. CTCs from patients and CD45-negative cells from healthy individuals were isolated each day using enrichment protocols, and qPCR was performed to determine expression levels of genes encoding specific biological markers. In addition, cells from breast and colon cancer cell lines were spiked into blood samples from healthy individuals, and these samples were stored and analyzed over a period of 96 h by PCR and by flow cytometry. The markers that were studied included housekeeping genes and genes associated with the response to chemotherapy, as well as genes encoding transcription factors. The results demonstrated that the expression profiles of specific genes and proteins in CTCs were not significantly affected by 72 h of storage. After 96 h of storage, expression of some genes was altered. The transportation of blood at low temperature (2-8 °C) in the presence of the anticoagulant EDTA can protect CTCs from alteration of gene and protein expression for at least 72 h. Furthermore, under these conditions, CTCs can be detected and isolated 96 h after

  16. THC and CBD in blood samples and seizures in Norway: Does CBD affect THC-induced impairment in apprehended subjects?

    PubMed

    Havig, Stine Marie; Høiseth, Gudrun; Strand, Maren Cecilie; Karinen, Ritva Anneli; Brochmann, Gerd-Wenche; Strand, Dag Helge; Bachs, Liliana; Vindenes, Vigdis

    2017-07-01

    Several publications have suggested increasing cannabis potency over the last decade, which, together with lower amounts of cannabidiol (CBD), could contribute to an increase in adverse effects after cannabis smoking. Naturalistic studies on tetrahydrocannabinol (THC) and CBD in blood samples are, however, missing. This study aimed to investigate the relationship between THC- and CBD concentrations in blood samples among cannabis users, and to compare cannabinoid concentrations with the outcome of a clinical test of impairment (CTI) and between traffic accidents and non-accident driving under the influence of drugs (DUID)-cases. Assessment of THC- and CBD contents in cannabis seizures was also included. THC- and CBD concentrations in blood samples from subjects apprehended in Norway from April 2013-April 2015 were included (n=6134). A CTI result was compared with analytical findings in cases where only THC and/or CBD were detected (n=705). THC- and CBD content was measured in 41 cannabis seizures. Among THC-positive blood samples, 76% also tested positive for CBD. There was a strong correlation between THC- and CBD concentrations in blood samples (Pearson's r=0.714, p<0.0005). Subjects judged as impaired by a CTI had significantly higher THC- (p<0.001) and CBD (p=0.008) concentrations compared with not impaired subjects, but after multivariate analyses, impairment could only be related to THC concentration (p=0.004). Analyzing seizures revealed THC/CBD ratios of 2:1 for hashish and 200:1 for marijuana. More than ¾ of the blood samples testing positive for THC, among subjects apprehended in Norway, also tested positive for CBD, suggesting frequent consumption of high CBD cannabis products. The simultaneous presence of CBD in blood does, however, not appear to affect THC-induced impairment on a CTI. Seizure sample analysis did not reveal high potency cannabis products, and while CBD content appeared high in hashish, it was almost absent in marijuana. Copyright

  17. T2 Magnetic Resonance Assay-Based Direct Detection of Three Lyme Disease-Related Borrelia Species in Whole-Blood Samples.

    PubMed

    Snyder, Jessica L; Giese, Heidi; Bandoski-Gralinski, Cheryl; Townsend, Jessica; Jacobson, Beck E; Shivers, Robert; Schotthoefer, Anna M; Fritsche, Thomas R; Green, Clayton; Callister, Steven M; Branda, John A; Lowery, Thomas J

    2017-08-01

    In early Lyme disease (LD), serologic testing is insensitive and seroreactivity may reflect active or past infection. In this study, we evaluated a novel assay for the direct detection of three species of Borrelia spirochetes in whole blood. The T2 magnetic resonance (T2MR) assay platform was used to amplify Borrelia DNA released from intact spirochetes and to detect amplicon. Analytical sensitivity was determined from blood spiked with known concentrations of spirochetes, and the assay's limit of detection was found to be in the single-cell-per-milliliter range: 5 cells/ml for B. afzelii and 8 cells/ml for Borrelia burgdorferi and Borrelia garinii Clinical samples ( n = 66) from confirmed or suspected early LD patients were also analyzed. B. burgdorferi was detected using T2MR in 2/2 (100%) of blood samples from patients with confirmed early LD, based on the presence of erythema migrans and documentation of seroconversion or a positive real-time blood PCR. T2MR detected B. burgdorferi in blood samples from 17/54 (31%) of patients with probable LD, based on the presence of erythema migrans without documented seroconversion or of documented seroconversion in patients with a compatible clinical syndrome but without erythema migrans. Out of 21 clinical samples tested by real-time PCR, only 1 was positive and 13 were negative with agreement with T2MR. An additional 7 samples that were negative by real-time PCR were positive with T2MR. Therefore, T2MR enables a low limit of detection (LoD) for Borrelia spp. in whole blood samples and is able to detect B. burgdorferi in clinical samples. Copyright © 2017 American Society for Microbiology.

  18. Boron detection from blood samples by ICP-AES and ICP-MS during boron neutron capture therapy.

    PubMed

    Linko, S; Revitzer, H; Zilliacus, R; Kortesniemi, M; Kouri, M; Savolainen, S

    2008-01-01

    The concept of boron neutron capture therapy (BNCT) involves infusion of a (10)B containing tracer into the patient's bloodstream followed by local neutron irradiation(s). Accurate estimation of the blood boron level for the treatment field before irradiation is required. Boron concentration can be quantified by inductively coupled plasma atomic emission spectrometry (ICP-AES), mass spectrometry (ICP-MS), spectrofluorometric and direct current atomic emission spectrometry (DCP-AES) or by prompt gamma photon detection methods. The blood boron concentrations were analysed and compared using ICP-AES and ICP-MS to ensure congruency of the results if the analysis had to be changed during the treatment, e.g. for technical reasons. The effect of wet-ashing on the results was studied in addition. The mean of all samples analysed with ICP-MS was 5.8 % lower than with ICP-AES coupled to wet-ashing (R (2) = 0.88). Without wet-ashing, the mean of all samples analysed with ICP-MS was 9.1 % higher than with ICP-AES (R (2) = 0.99). Boron concentration analysed from whole blood samples with ICP-AES correlated well with the values of ICP-MS with wet-ashing of the sample matrix, which is generally considered the reference method. When using these methods in parallel at certain intervals during the treatments, reliability of the blood boron concentration values remains satisfactory, taking into account the required accuracy of dose determination in the irradiation of cancer patients.

  19. Quantitative determination of atenolol in dried blood spot samples by LC-HRMS: a potential method for assessing medication adherence.

    PubMed

    Lawson, Graham; Cocks, Elizabeth; Tanna, Sangeeta

    2012-05-15

    The use of blood spot collection cards was investigated as a means of obtaining small volume samples for the quantification of therapeutic drugs for assessing medication adherence. A liquid chromatography-high resolution TOF mass spectrometry (LC-HRMS) method, based on the measurement at the accurate mass to charge ratio of the target analyte, was used to ensure specificity for atenolol in the dried blood spot (DBS) samples. A working method was developed and validated. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30 μl blood spots on specimen collection cards. A 5mm disc was cut from the dried blood spot and extracted using methanol:water (60:40, v/v) containing the internal standard, atenolol-d(7). Extracts were vortexed, sonicated and then centrifuged. Gradient chromatographic elution was achieved using an Ascentis Express C18 100mm×2.1mm column and a mobile phase flow rate of 0.2 ml/min and the column oven temperature at 30 °C. MS detection was carried out in electrospray positive ion mode for target ions at accurate mass m/z 267.1703 for atenolol and 274.2143 for the IS. Drug extraction efficiency from spiked blood spots was demonstrated to be 96±5% and the drug was stable in DBS for at least 10 weeks. The developed LC-HRMS method was linear within the tested calibration range of 25-1500 ng/ml and validation showed the accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤ 5% at all concentrations with a limit of quantification of 25 ng/ml. Factors with potential to affect drug quantification measurements such as the matrix effects, volume of blood applied onto the collection card and effect of different sampling cards were investigated. The developed LC-HRMS method was applied to blood spots on sampling card taken from adult healthy volunteers previously administered a 50mg atenolol tablet and a DBS concentration-time profile was obtained for atenolol

  20. Dried Blood Spot Proteomics: Surface Extraction of Endogenous Proteins Coupled with Automated Sample Preparation and Mass Spectrometry Analysis

    NASA Astrophysics Data System (ADS)

    Martin, Nicholas J.; Bunch, Josephine; Cooper, Helen J.

    2013-08-01

    Dried blood spots offer many advantages as a sample format including ease and safety of transport and handling. To date, the majority of mass spectrometry analyses of dried blood spots have focused on small molecules or hemoglobin. However, dried blood spots are a potentially rich source of protein biomarkers, an area that has been overlooked. To address this issue, we have applied an untargeted bottom-up proteomics approach to the analysis of dried blood spots. We present an automated and integrated method for extraction of endogenous proteins from the surface of dried blood spots and sample preparation via trypsin digestion by use of the Advion Biosciences Triversa Nanomate robotic platform. Liquid chromatography tandem mass spectrometry of the resulting digests enabled identification of 120 proteins from a single dried blood spot. The proteins identified cross a concentration range of four orders of magnitude. The method is evaluated and the results discussed in terms of the proteins identified and their potential use as biomarkers in screening programs.

  1. Quantitative Analysis of Therapeutic Drugs in Dried Blood Spot Samples by Paper Spray Mass Spectrometry: An Avenue to Therapeutic Drug Monitoring

    NASA Astrophysics Data System (ADS)

    Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham

    2011-09-01

    A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.

  2. Severe anaemia associated with Plasmodium falciparum infection in children: consequences for additional blood sampling for research.

    PubMed

    Kuijpers, Laura Maria Francisca; Maltha, Jessica; Guiraud, Issa; Kaboré, Bérenger; Lompo, Palpouguini; Devlieger, Hugo; Van Geet, Chris; Tinto, Halidou; Jacobs, Jan

    2016-06-02

    Plasmodium falciparum infection may cause severe anaemia, particularly in children. When planning a diagnostic study on children suspected of severe malaria in sub-Saharan Africa, it was questioned how much blood could be safely sampled; intended blood volumes (blood cultures and EDTA blood) were 6 mL (children aged <6 years) and 10 mL (6-12 years). A previous review [Bull World Health Organ. 89: 46-53. 2011] recommended not to exceed 3.8 % of total blood volume (TBV). In a simulation exercise using data of children previously enrolled in a study about severe malaria and bacteraemia in Burkina Faso, the impact of this 3.8 % safety guideline was evaluated. For a total of 666 children aged >2 months to <12 years, data of age, weight and haemoglobin value (Hb) were available. For each child, the estimated TBV (TBVe) (mL) was calculated by multiplying the body weight (kg) by the factor 80 (ml/kg). Next, TBVe was corrected for the degree of anaemia to obtain the functional TBV (TBVf). The correction factor consisted of the rate 'Hb of the child divided by the reference Hb'; both the lowest ('best case') and highest ('worst case') reference Hb values were used. Next, the exact volume that a 3.8 % proportion of this TBVf would present was calculated and this volume was compared to the blood volumes that were intended to be sampled. When applied to the Burkina Faso cohort, the simulation exercise pointed out that in 5.3 % (best case) and 11.4 % (worst case) of children the blood volume intended to be sampled would exceed the volume as defined by the 3.8 % safety guideline. Highest proportions would be in the age groups 2-6 months (19.0 %; worst scenario) and 6 months-2 years (15.7 %; worst case scenario). A positive rapid diagnostic test for P. falciparum was associated with an increased risk of violating the safety guideline in the worst case scenario (p = 0.016). Blood sampling in children for research in P. falciparum endemic settings may easily violate

  3. Quantification of Rifapentine, a Potent Antituberculosis Drug, from Dried Blood Spot Samples Using Liquid Chromatographic-Tandem Mass Spectrometric Analysis

    PubMed Central

    Parsons, Teresa L.; Marzinke, Mark A.; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R.; Dorman, Susan E.

    2014-01-01

    The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637

  4. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry.

    PubMed

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.

  5. Antiretroviral treatment interruptions induced by the Kenyan postelection crisis are associated with virological failure.

    PubMed

    Mann, Marita; Diero, Lameck; Kemboi, Emmanuel; Mambo, Fidelis; Rono, Mary; Injera, Wilfred; Delong, Allison; Schreier, Leeann; Kaloustian, Kara W; Sidle, John; Buziba, Nathan; Kantor, Rami

    2013-10-01

    Antiretroviral treatment interruptions (TIs) cause suboptimal clinical outcomes. Data on TIs during social disruption are limited. We determined effects of unplanned TIs after the 2007-2008 Kenyan postelection violence on virological failure, comparing viral load (VL) outcomes in HIV-infected adults with and without conflict-induced TI. Two hundred and one patients were enrolled, median 2.2 years after conflict and 4.3 years on treatment. Eighty-eight patients experienced conflict-related TIs and 113 received continuous treatment. After adjusting for preconflict CD4, patients with TIs were more likely to have detectable VL, VL >5,000 and VL >10,000. Unplanned conflict-related TIs are associated with increased likelihood of virological failure.

  6. Distribution of blood types in a sample of 245 New Zealand non-purebred cats.

    PubMed

    Cattin, R P

    2016-05-01

    To determine the distribution of feline blood types in a sample of non-pedigree, domestic cats in New Zealand, whether a difference exists in this distribution between domestic short haired and domestic long haired cats, and between the North and South Islands of New Zealand; and to calculate the risk of a random blood transfusion causing a severe transfusion reaction, and the risk of a random mating producing kittens susceptible to neonatal isoerythrolysis. The results of 245 blood typing tests in non-pedigree cats performed at the New Zealand Veterinary Pathology (NZVP) and Gribbles Veterinary Pathology laboratories between the beginning of 2009 and the end of 2014 were retrospectively collated and analysed. Cats that were identified as domestic short or long haired were included. For the cats tested at Gribbles Veterinary Pathology 62 were from the North Island, and 27 from the South Island. The blood type distribution differed between samples from the two laboratories (p=0.029), but not between domestic short and long haired cats (p=0.50), or between the North and South Islands (p=0.76). Of the 89 cats tested at Gribbles Veterinary Pathology, 70 (79%) were type A, 18 (20%) type B, and 1 (1%) type AB; for NZVP 139/156 (89.1%) cats were type A, 16 (10.3%) type B, and 1 (0.6%) type AB. It was estimated that 18.3-31.9% of random blood transfusions would be at risk of a transfusion reaction, and neonatal isoerythrolysis would be a risk in 9.2-16.1% of random matings between non-pedigree cats. The results from this study suggest that there is a high risk of complications for a random blood transfusion between non-purebred cats in New Zealand. Neonatal isoerythrolysis should be considered an important differential diagnosis in illness or mortality in kittens during the first days of life.

  7. Long-term stability of morphine, codeine, and 6-acetylmorphine in real-life whole blood samples, stored at -20°C.

    PubMed

    Høiseth, Gudrun; Fjeld, Bente; Burns, Margrete Larsen; Strand, Dag Helge; Vindenes, Vigdis

    2014-06-01

    Stability of drugs during storage is important in forensic toxicology. For the analytes detected after intake of heroin (6-acetylmorphine (6-AM), morphine and codeine), long-time stability in real life whole blood samples are studied in only a small number of cases. Whole blood post mortem (n=37) and whole blood samples from living persons (n=22) containing morphine and codeine as well as 6-AM in blood or urine were selected. All cases represented intake of heroin. All samples contained fluoride and were initially analysed and stored in normal conditions (-20°C) for 4-9 years. All samples were then reanalysed using the same analytical methods and the results were compared. For samples from living persons, the median change in concentration was -3.7% for morphine and -5.3% for codeine. For post mortem samples, the median change in concentration was -12% for morphine and -11% for codeine. Both for samples from living persons and post mortem samples, the decrease in the concentrations from the original analysis to reanalysis were statistically significant for morphine and codeine. Regarding 6-AM, all living samples were negative at reanalysis. For post mortem samples, four cases still tested positive for 6-AM at reanalysis with a median change in the concentrations of -81%. There was no significant change in the morphine to codeine concentration ratios neither for living nor post mortem samples. This study showed that in real life whole blood samples, the concentrations of morphine and codeine are relatively stable during long-term storage at -20°C. 6-AM on the other hand, shows a considerable decrease in concentrations that is important to consider when interpreting results from reanalyses of forensic cases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. The Africa Yoga Project: A Participant-Driven Concept Map of Kenyan Teachers' Reported Experiences.

    PubMed

    Klein, Jessalyn E; Cook-Cottone, Catherine; Giambrone, Carla

    2015-01-01

    The Africa Yoga Project (AYP) trains and funds Kenyans to teach community yoga classes. Preliminary research with a small sample of AYP teachers suggested the program had a positive impact. This study used concept mapping to explore the experiences of a larger sample. Participants brainstormed statements about how practicing and/or teaching yoga changed them. They sorted statements into self-defined piles and rated them in terms of perceived importance. Multidimensional scaling (MDS) of sort data calculated statement coordinates wherein each statement is placed in proximity to other statements as a function of how frequently statements are sorted together by participants. These results are then and mapped in a two-dimensional space. Hierarchical cluster analysis (HCA) of these data identified clusters (i.e., concepts) among statements. Cluster average importance ratings gave the concept map depth and indicated concept importance. Bridging analysis and researchers' conceptual understanding of yoga literature facilitated HCA interpretive decisions. Of 72 AYP teachers, 52 and 48 teachers participated in brainstorming and sorting/rating activities, respectively. Teachers brainstormed 93 statements about how they had changed. The resultant MDS statement map had adequate validity (stress value = .29). HCA created a 12-cluster solution with the following concepts of perceived change: Identity as a Yoga Teacher; Prosocial Development; Existential Possibility; Genuine Positive Regard; Value and Respect for Others (highest importance); Presence, Acceptance, and Competence; Service and Trust; Non-judgment and Emotion Regulation (lowest importance); Engagement and Connection; Interpersonal Effectiveness; Psychosocial Functioning; and Physical Competence and Security. Teachers perceived the AYP as facilitating change across physical, mental, and spiritual domains. Additional research is needed to quantify and compare this change to other health promotion program outcomes.

  9. Screening for glucose-6-phosphate dehydrogenase deficiency in neonates: a comparison between cord and peripheral blood samples.

    PubMed

    AlSaif, Saif; Ponferrada, Ma Bella; AlKhairy, Khalid; AlTawil, Khalil; Sallam, Adel; Ahmed, Ibrahim; Khawaji, Mohammed; AlHathlol, Khalid; Baylon, Beverly; AlSuhaibani, Ahmed; AlBalwi, Mohammed

    2017-07-11

    The use of cord blood in the neonatal screening for glucose-6-phosphate dehydrogenase (G6PD) deficiency is being done with increasing frequency but has yet to be adequately evaluated against the use of peripheral blood sample which is usually employed for confirmation. We sought to determine the incidence and gender distribution of G6PD deficiency, and compare the results of cord against peripheral blood in identifying G6PD DEFICIENCY neonates using quantitative enzyme activity assay. We carried out a retrospective and cross-sectional study employing review of primary hospital data of neonates born in a tertiary care center from January to December 2008. Among the 8139 neonates with cord blood G6PD assays, an overall incidence of 2% for G6PD deficiency was computed. 79% of these were males and 21% were females with significantly more deficient males (p < .001). Gender-specific incidence was 3.06% for males and 0.85% for females. A subgroup analysis comparing cord and peripheral blood samples (n = 1253) showed a significantly higher mean G6PD value for peripheral than cord blood (15.12 ± 4.52 U/g and 14.52 ± 4.43 U/g, respectively, p = 0.0008). However, the proportion of G6PD deficient neonates did not significantly differ in the two groups (p = 0.79). Sensitivity of cord blood in screening for G6PD deficiency, using peripheral G6PD assay as a gold standard was 98.6% with a NPV of 99.5%. There was no difference between cord and peripheral blood samples in discriminating between G6PD deficient and non-deficient neonates. A significantly higher mean peripheral G6PD assay reinforces the use of cord blood for neonatal screening since it has substantially low false negative results.

  10. The plasma virome of febrile adult Kenyans shows frequent parvovirus B19 infections and a novel arbovirus (Kadipiro virus).

    PubMed

    Ngoi, Carolyne N; Siqueira, Juliana; Li, Linlin; Deng, Xutao; Mugo, Peter; Graham, Susan M; Price, Matt A; Sanders, Eduard J; Delwart, Eric

    2016-12-01

    Viral nucleic acids present in the plasma of 498 Kenyan adults with unexplained fever were characterized by metagenomics analysis of 51 sample pools. The highest to lowest fraction of plasma pools was positive for parvovirus B19 (75 %), pegivirus C (GBV-C) (67 %), alpha anellovirus (59 %), gamma anellovirus (55 %), beta anellovirus (41 %), dengue virus genotype 2 (DENV-2) (16 %), human immunodeficiency virus type 1 (6 %), human herpesvirus 6 (6 %), HBV (4 %), rotavirus (4 %), hepatitis B virus (4 %), rhinovirus C (2 %), Merkel cell polyomavirus (MCPyV; 2 %) and Kadipiro virus (2 %). Ranking by overall percentage of viral reads yielded similar results. Characterization of viral nucleic acids in the plasma of a febrile East African population showed a high frequency of parvovirus B19 and DENV infections and detected a reovirus (Kadipiro virus) previously reported only in Asian Culex mosquitoes, providing a baseline to compare with future virome studies to detect emerging viruses in this region.

  11. The plasma virome of febrile adult Kenyans shows frequent parvovirus B19 infections and a novel arbovirus (Kadipiro virus)

    PubMed Central

    Ngoi, Carolyne N.; Siqueira, Juliana; Li, Linlin; Deng, Xutao; Mugo, Peter; Graham, Susan M.; Price, Matt A.; Sanders, Eduard J.

    2016-01-01

    Viral nucleic acids present in the plasma of 498 Kenyan adults with unexplained fever were characterized by metagenomics analysis of 51 sample pools. The highest to lowest fraction of plasma pools was positive for parvovirus B19 (75 %), pegivirus C (GBV-C) (67 %), alpha anellovirus (59 %), gamma anellovirus (55 %), beta anellovirus (41 %), dengue virus genotype 2 (DENV-2) (16 %), human immunodeficiency virus type 1 (6 %), human herpesvirus 6 (6 %), HBV (4 %), rotavirus (4 %), hepatitis B virus (4 %), rhinovirus C (2 %), Merkel cell polyomavirus (MCPyV; 2 %) and Kadipiro virus (2 %). Ranking by overall percentage of viral reads yielded similar results. Characterization of viral nucleic acids in the plasma of a febrile East African population showed a high frequency of parvovirus B19 and DENV infections and detected a reovirus (Kadipiro virus) previously reported only in Asian Culex mosquitoes, providing a baseline to compare with future virome studies to detect emerging viruses in this region. PMID:27902331

  12. Male and female Ethiopian and Kenyan runners are the fastest and the youngest in both half and full marathon.

    PubMed

    Knechtle, Beat; Nikolaidis, Pantelis T; Onywera, Vincent O; Zingg, Matthias A; Rosemann, Thomas; Rüst, Christoph A

    2016-01-01

    In major marathon races such as the 'World Marathon Majors', female and male East African runners particularly from Ethiopia and Kenya are the fastest. However, whether this trend appears for female and male Ethiopians and Kenyans at recreational level runners (i.e. races at national level) and in shorter road races (e.g. in half-marathon races) has not been studied yet. Thus, the aim of the present study was to examine differences in the performance and the age of female and male runners from East Africa (i.e. Ethiopians and Kenyans) between half- and full marathons. Data from 508,108 athletes (125,894 female and 328,430 male half-marathoners and 10,205 female and 43,489 male marathoners) originating from 126 countries and competing between 1999 and 2014 in all road-based half-marathons and marathons held in one country (Switzerland) were analysed using Chi square (χ(2)) tests, mixed-effects regression analyses and one-way analyses of variance. In half-marathons, 48 women (0.038 %) and 63 men (0.019 %) were from Ethiopia and 80 women (0.063 %) and 134 men (0.040 %) from Kenya. In marathons, three women (0.029 %) and 15 men (0.034 %) were from Ethiopia and two women (0.019 %) and 33 men (0.075 %) from Kenya. There was no statistically significant association between the nationality of East Africans and the format of a race. In both women and men, the fastest race times in half-marathons and marathons were achieved by East African runners (p < 0.001). Ethiopian and Kenyan runners were the youngest in both sexes and formats of race (p < 0.001). In summary, women and men from Ethiopia and Kenya, despite they accounted for <0.1 % in half-marathons and marathons, achieved the fastest race times and were the youngest in both half-marathons and marathons. These findings confirmed in the case of half-marathon the trend previously observed in marathon races for a better performance and a younger age in East African runners from Ethiopia and Kenya.

  13. Comparison of haematology, coagulation and clinical chemistry parameters in blood samples from the sublingual vein and vena cava in Sprague-Dawley rats.

    PubMed

    Seibel, J; Bodié, K; Weber, S; Bury, D; Kron, M; Blaich, G

    2010-10-01

    The investigation of clinical pathology parameters (haematology, clinical chemistry and coagulation) is an important part of the preclinical evaluation of drug safety. However, the blood sampling method employed should avoid or minimize stress and injury in laboratory animals. In the present study, we compared the clinical pathology results from blood samples collected terminally from the vena cava (VC) immediately before necropsy with samples taken from the sublingual vein (VS) also prior to necropsy in order to determine whether the sampling method has an influence on clinical pathology parameters. Forty-six 12-week-old male Sprague-Dawley rats were assigned to two groups (VC or VS; n = 23 each). All rats were anaesthetized with isoflurane prior to sampling. In the VC group, blood was withdrawn from the inferior VC. For VS sampling, the tongue was gently pulled out and the VS was punctured. The haematology, coagulation and clinical chemistry parameters were compared. Equivalence was established for 13 parameters, such as mean corpuscular volume, white blood cells and calcium. No equivalence was found for the remaining 26 parameters, although they were considered to be similar when compared with the historical data and normal ranges. The most conspicuous finding was that activated prothrombin time was 30.3% less in blood taken from the VC (16.6 ± 0.89 s) than that in the VS samples (23.8 ± 1.58 s). Summing up, blood sampling from the inferior VC prior to necropsy appears to be a suitable and reliable method for terminal blood sampling that reduces stress and injury to laboratory rats in preclinical drug safety studies.

  14. Sampling blood from big brown bats (Eptesicus fuscus) in the field with and without anesthesia: impacts on survival.

    PubMed

    Ellison, Laura E; O'Shea, Thomas J; Wimsatt, Jeffrey; Pearce, Roger D; Neubaum, Daniel J; Neubaum, Melissa A; Bowen, Richard A

    2006-10-01

    Blood was collected from wild big brown bats (Eptesicus fuscus) with and without anesthesia in Fort Collins, Colorado in 2004 to assess the impacts of these procedures on short-term survival and 1-yr return rates. Short-term survival and 1-yr return rates after release were passively monitored using PIT tag detection hoops placed at selected buildings. Comparison of 14-day maximum likelihood survival estimates from bats not bled (142 adult females, 62 volant juveniles), and bats sampled for blood with anesthesia (96 adult females, 23 volant juveniles) and without anesthesia (112 adult females, 22 volant juveniles) indicated no adverse effects of either treatment (juveniles: chi(2) = 53.38, df = 41, P = 0.09; adults: chi(2) = 39.09, df = 44, P = 0.68). Return rates of bats one year after sampling were similar among adult female controls (75.4%, n = 142, 95% CI = 67.4-82.2%), females sampled for blood with anesthesia (83.0%, n = 112, 95% CI = 74.8-89.5%), and females sampled without anesthesia (87.5%, n = 96, 95% CI = 79.2-93.4%). Lack of an effect was also noted in 1-yr return rates of juvenile females. These data suggest that the use of anesthesia during sampling of blood has no advantages in terms of enhancement of survival in big brown bats.

  15. Sampling blood from big brown bats (Eptesicus fuscus) in the field with and without anesthesia: Impacts on survival

    USGS Publications Warehouse

    Ellison, L.E.; O'Shea, T.J.; Wimsatt, J.; Pearce, R.D.; Neubaum, D.J.; Neubaum, M.A.; Bowen, R.A.

    2006-01-01

    Blood was collected from wild big brown bats (Eptesicus fuscus) with and without anesthesia in Fort Collins, Colorado in 2004 to assess the impacts of these procedures on short-term survival and 1-yr return rates. Short-term survival and 1-yr return rates after release were passively monitored using PIT tag detection hoops placed at selected buildings. Comparison of 14-day maximum likelihood survival estimates from bats not bled (142 adult females, 62 volant juveniles), and bats sampled for blood with anesthesia (96 adult females, 23 volant juveniles) and without anesthesia (112 adult females, 22 volant juveniles) indicated no adverse effects of either treatment (juveniles: X2=53.38, df=41, P=0.09; adults: X2=39.09, df=44, P=0.68). Return rates of bats one year after sampling were similar among adult female controls (75.4%, n=142, 95% CI=67.4-82.2%), females sampled for blood with anesthesia (83.0%, n=112, 95% CI=74.8-89.5%), and females sampled without anesthesia (87.5%, n=96, 95% CI=79.2-93.4%). Lack of an effect was also noted in 1-yr return rates of juvenile females. These data suggest that the use of anesthesia during sampling of blood has no advantages in terms of enhancement of survival in big brown bats. ?? Wildlife Disease Association 2006.

  16. [A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].

    PubMed

    Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N

    1995-04-01

    We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.

  17. Evaluating the effect of sample type on American alligator ( Alligator mississippiensis) analyte values in a point-of-care blood analyser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less

  18. Evaluating the effect of sample type on American alligator (Alligator mississippiensis) analyte values in a point-of-care blood analyser

    PubMed Central

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; Tuberville, Tracey D.

    2016-01-01

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressure of carbon dioxide (PCO2), bicarbonate (HCO3−), total carbon dioxide (TCO2), base excess (BE), partial pressure of oxygen (PO2), oxygen saturation (sO2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. Lastly, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood. PMID:27382469

  19. Evaluating the effect of sample type on American alligator ( Alligator mississippiensis) analyte values in a point-of-care blood analyser

    DOE PAGES

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; ...

    2016-01-01

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less

  20. Correlation between Na/K ratio and electron densities in blood samples of breast cancer patients.

    PubMed

    Topdağı, Ömer; Toker, Ozan; Bakırdere, Sezgin; Bursalıoğlu, Ertuğrul Osman; Öz, Ersoy; Eyecioğlu, Önder; Demir, Mustafa; İçelli, Orhan

    2018-05-31

    The main purpose of this study was to investigate the relationship between the electron densities and Na/K ratio which has important role in breast cancer disease. Determinations of sodium and potassium concentrations in blood samples performed with inductive coupled plasma-atomic emission spectrometry. Electron density values of blood samples were determined via ZXCOM. Statistical analyses were performed for electron densities and Na/K ratio including Kolmogorov-Smirnov normality tests, Spearman's rank correlation test and Mann-Whitney U test. It was found that the electron densities significantly differ between control and breast cancer groups. In addition, statistically significant positive correlation was found between the electron density and Na/K ratios in breast cancer group.

  1. Analysis of evolutionary rate of HIV-1 subtype B using blood donor samples in Japan.

    PubMed

    Shinohara, Naoya; Matsumoto, Chieko; Matsubayashi, Keiji; Nagai, Tadashi; Satake, Masahiro

    2018-06-01

    There are few reports on HIV-1 intra-host evolutionary rate in asymptomatic treatment-naïve patients. Here, the HIV-1 intra-host evolutionary rate was estimated based on HIV-1 RNA sequences from plasma samples of blood donors in Japan. Blood donors were assumed to have received no treatment for and have no symptoms of HIV-1 infection because they were healthy, and declared no risky behaviors of HIV-1 infection on a self-reported questionnaire or interview followed by donation. HIV-1 RNA was obtained from 85 plasma samples from 36 blood donors who donated blood multiple times and were HIV-1-positive. The C2V3C3 region which encodes for a part of the envelope protein, and the V3 loop in the C2V3C3 region were analyzed by RT-PCR and direct sequencing, and the sequences were compared. The nucleotide substitution rate was calculated by linear regression. All HIV-1 samples analyzed were classified as subtype B. The mean nucleotide substitution rate in C2V3C3 was calculated to be 6.2 × 10 -3 -1.8 × 10 -2 /site/year (V3: 4.5 × 10 -3 -2.3 × 10 -2 /site/year). The mean non-synonymous substitution rate in C2V3C3 was calculated to be 5.2 × 10 -3 -1.7 × 10 -2 /site/year (V3: 4.5 × 10 -3 -2.1 × 10 -2 /site/year). The mean synonymous substitution rate in C2V3C3 was calculated to be 1.1 × 10 -4 -2.3 × 10 -3 /site/year (V3: 2.9 × 10 -3 /site/year). Among HIV-1 subtype B RNA-positive blood donors in Japan, the nucleotide substitution rate in C2V3C3 was estimated to be higher than that of reported cases using HIV-1 samples mainly obtained from AIDS patients. Compared to AIDS patients, immune responses against HIV-1 are probably more effective in HIV-1 RNA-positive blood donors. Consequently, immune pressure presumably promotes mutation of the virus genome.

  2. Kenyan who "discovered the cure for AIDS" taken to court.

    PubMed

    1996-06-01

    In Nairobi, Kenya, Professor Obel, the Kenyan scientist who produced two drugs that he claimed would cure acquired immunodeficiency syndrome (AIDS), is being taken to court, and Pearl Omega, one of the drugs, has been banned by the Ministry of Health. Initially, Obel may have gained support in the ministry because of his friendship with Phillip Mbithi, former Chief Secretary in the office of the president, and others. Obel claimed in March to have found a cure for AIDS; he was lambasted by scientists. On April 24, Assistant Health Minister Basil Criticos told parliament that the government was to carry out clinical trials of the drug and that Obel was to be encouraged. On May 2, Health Minister Joshua Angatia stated that Pearl Omega was a herbal concoction whose efficacy had never scientifically been proven. The Society of People with AIDS in Kenya has taken Obel to court; some patients who had taken part in trials of Kemron, Obel's other miracle drug, had been told by the professor that they had become HIV-negative.

  3. Array CGH Analysis of Paired Blood and Tumor Samples from Patients with Sporadic Wilms Tumor

    PubMed Central

    del Carmen Crespo, María; Vallespín, Elena; Palomares-Bralo, María; Martin-Arenas, Rubén; Rueda-Arenas, Inmaculada; Silvestre de Faria, Paulo Antonio; García-Miguel, Purificación; Lapunzina, Pablo; Regla Vargas, Fernando; Seuanez, Hector N.; Martínez-Glez, Víctor

    2015-01-01

    Wilms tumor (WT), the most common cancer of the kidney in infants and children, has a complex etiology that is still poorly understood. Identification of genomic copy number variants (CNV) in tumor genomes provides a better understanding of cancer development which may be useful for diagnosis and therapeutic targets. In paired blood and tumor DNA samples from 14 patients with sporadic WT, analyzed by aCGH, 22% of chromosome abnormalities were novel. All constitutional alterations identified in blood were segmental (in 28.6% of patients) and were also present in the paired tumor samples. Two segmental gains (2p21 and 20q13.3) and one loss (19q13.31) present in blood had not been previously described in WT. We also describe, for the first time, a small, constitutive partial gain of 3p22.1 comprising 2 exons of CTNNB1, a gene associated to WT. Among somatic alterations, novel structural chromosomal abnormalities were found, like gain of 19p13.3 and 20p12.3, and losses of 2p16.1-p15, 4q32.5-q35.1, 4q35.2-q28.1 and 19p13.3. Candidate genes included in these regions might be constitutively (SIX3, SALL4) or somatically (NEK1, PIAS4, BMP2) operational in the development and progression of WT. To our knowledge this is the first report of CNV in paired blood and tumor samples in sporadic WT. PMID:26317783

  4. Conditions in blood sampling procedures that extend the ex vivo stability of eosinophil activity markers in peripheral blood from allergic patients and healthy controls.

    PubMed

    Halldén, G; Nopp, A; Ihre, E; Peterson, C; Lundahl, J

    1999-11-01

    Serum-ECP, EG2-epitope on intracellular ECP and surface expression of CD9 and CD11b in peripheral blood eosinophils (PBE) are considered to be markers that mirror clinical parameters in allergic inflammation. The aim was to investigate the impact of the blood sampling procedure on PBE markers and to identify optimal conditions for extended pre-analysis storage. Blood, from healthy individuals and patients with allergic rhinitis/asthma, was collected in tubes with EDTA, citrate, or without anti-coagulant. The expression of EG2-epitope, CD9, and CD11b were analyzed in eosinophils and neutrophils after 1, 5, and 24 hours of storage at +4 degrees C, according to the FOG-method and flow cytometry. In vitro stimulation with fMLP/PMA was used for metabolic activity analysis and CD11b mobilization. Following a 1-hour clotting period at +20 to 22 degrees C, samples were stored at +4 degrees C and serum-ECP levels were measured. The EG2-epitope, serum-ECP, and CD9 were stable in samples from both healthy controls and allergic patients at all storage conditions. The EG2-epitope, serum-ECP and PBE count were significantly increased in the patient group, whereas no differences were observed in the expression of CD9 or CD11b. Both granulocytes and monocytes retained their metabolic activity for 24 hours. Neutrophils in citrate-blood increased their ability to respond to fMLP, as compared with EDTA-blood. In vitro analysis of selected activity markers and functional tests could be performed on granulocytes from both healthy individuals and allergic patients after 24 hours storage at +4 degrees C. The anticoagulant citrate seems to be preferable to EDTA when monocytes or CD11b expression are analyzed.

  5. Detection of Streptococcus mutans Genomic DNA in Human DNA Samples Extracted from Saliva and Blood

    PubMed Central

    Vieira, Alexandre R.; Deeley, Kathleen B.; Callahan, Nicholas F.; Noel, Jacqueline B.; Anjomshoaa, Ida; Carricato, Wendy M.; Schulhof, Louise P.; DeSensi, Rebecca S.; Gandhi, Pooja; Resick, Judith M.; Brandon, Carla A.; Rozhon, Christopher; Patir, Asli; Yildirim, Mine; Poletta, Fernando A.; Mereb, Juan C.; Letra, Ariadne; Menezes, Renato; Wendell, Steven; Lopez-Camelo, Jorge S.; Castilla, Eduardo E.; Orioli, Iêda M.; Seymen, Figen; Weyant, Robert J.; Crout, Richard; McNeil, Daniel W.; Modesto, Adriana; Marazita, Mary L.

    2011-01-01

    Caries is a multifactorial disease, and studies aiming to unravel the factors modulating its etiology must consider all known predisposing factors. One major factor is bacterial colonization, and Streptococcus mutans is the main microorganism associated with the initiation of the disease. In our studies, we have access to DNA samples extracted from human saliva and blood. In this report, we tested a real-time PCR assay developed to detect copies of genomic DNA from Streptococcus mutans in 1,424 DNA samples from humans. Our results suggest that we can determine the presence of genomic DNA copies of Streptococcus mutans in both DNA samples from caries-free and caries-affected individuals. However, we were not able to detect the presence of genomic DNA copies of Streptococcus mutans in any DNA samples extracted from peripheral blood, which suggests the assay may not be sensitive enough for this goal. Values of the threshold cycle of the real-time PCR reaction correlate with higher levels of caries experience in children, but this correlation could not be detected for adults. PMID:21731912

  6. High-throughput rare cell separation from blood samples using steric hindrance and inertial microfluidics.

    PubMed

    Shen, Shaofei; Ma, Chao; Zhao, Lei; Wang, Yaolei; Wang, Jian-Chun; Xu, Juan; Li, Tianbao; Pang, Long; Wang, Jinyi

    2014-07-21

    The presence and quantity of rare cells in the bloodstream of cancer patients provide a potentially accessible source for the early detection of invasive cancer and for monitoring the treatment of advanced diseases. The separation of rare cells from peripheral blood, as a "virtual and real-time liquid biopsy", is expected to replace conventional tissue biopsies of metastatic tumors for therapy guidance. However, technical obstacles, similar to looking for a needle in a haystack, have hindered the broad clinical utility of this method. In this study, we developed a multistage microfluidic device for continuous label-free separation and enrichment of rare cells from blood samples based on cell size and deformability. We successfully separated tumor cells (MCF-7 and HeLa cells) and leukemic (K562) cells spiked in diluted whole blood using a unique complementary combination of inertial microfluidics and steric hindrance in a microfluidic system. The processing parameters of the inertial focusing and steric hindrance regions were optimized to achieve high-throughput and high-efficiency separation, significant advantages compared with existing rare cell isolation technologies. The results from experiments with rare cells spiked in 1% hematocrit blood indicated >90% cell recovery at a throughput of 2.24 × 10(7) cells min(-1). The enrichment of rare cells was >2.02 × 10(5)-fold. Thus, this microfluidic system driven by purely hydrodynamic forces has practical potential to be applied either alone or as a sample preparation platform for fundamental studies and clinical applications.

  7. Association between Macronutrients Intake, Visceral Obesity and Blood Pressure in a Sample of Obese Egyptian Women.

    PubMed

    Hassan, Nayera E; El Shebini, Salwa M; Ahmed, Nihad H; Selim Mostafa, Mohamed

    2015-03-15

    Study the association between the total caloric intake, protein, lipid, and some classes of fatty acids of the diet, and their effects on blood pressure in a sample of Egyptian obese women with and without visceral obesity. Five hundred forty-nine obese women were included in the study with mean age of 38.1 ± 11.56 years and mean Body mass index [BMI] of 36.17 ± 7.23. They enrolled in a program for losing weight. Visceral fat was determined using ultrasound. Blood pressure was measured 3 times and the mean was recorded. Twenty four hours dietary recall was reported. Thirty point four percentages of samples has visceral obesity ≥ 7cm; they were the older, showed higher values of BMI, visceral obesity and blood pressure. Significant difference was found between groups regarding mean value of BMI, visceral obesity, both systolic blood pressure SBP and diastolic blood pressure DBP and most of the daily macronutrients intake. In groups (2&3) positive significant correlation was recorded between (SBP) & (DBP) and total daily intake of total calories, carbohydrate, total fat, saturated fatty acids and cholesterol, and negative significant correlation with total daily intake of total protein, animal and vegetable protein, linolenic and linoleic fatty acids, while oleic fatty acid showed negative correlation with SBP&DBP in all groups. This study emphasizes the hypothesis that the macronutrients composition of diet influences blood pressure in different ways, in obese patients with visceral obesity.

  8. Association between Macronutrients Intake, Visceral Obesity and Blood Pressure in a Sample of Obese Egyptian Women

    PubMed Central

    Hassan, Nayera E.; El Shebini, Salwa M.; Ahmed, Nihad H.; Selim Mostafa, Mohamed

    2015-01-01

    AIM: Study the association between the total caloric intake, protein, lipid, and some classes of fatty acids of the diet, and their effects on blood pressure in a sample of Egyptian obese women with and without visceral obesity. METHODS: Five hundred forty-nine obese women were included in the study with mean age of 38.1 ± 11.56 years and mean Body mass index [BMI] of 36.17 ± 7.23. They enrolled in a program for losing weight. Visceral fat was determined using ultrasound. Blood pressure was measured 3 times and the mean was recorded. Twenty four hours dietary recall was reported. RESULTS: Thirty point four percentages of samples has visceral obesity ≥ 7cm; they were the older, showed higher values of BMI, visceral obesity and blood pressure. Significant difference was found between groups regarding mean value of BMI, visceral obesity, both systolic blood pressure SBP and diastolic blood pressure DBP and most of the daily macronutrients intake. In groups (2&3) positive significant correlation was recorded between (SBP) & (DBP) and total daily intake of total calories, carbohydrate, total fat, saturated fatty acids and cholesterol, and negative significant correlation with total daily intake of total protein, animal and vegetable protein, linolenic and linoleic fatty acids, while oleic fatty acid showed negative correlation with SBP&DBP in all groups. CONCLUSION: This study emphasizes the hypothesis that the macronutrients composition of diet influences blood pressure in different ways, in obese patients with visceral obesity. PMID:27275219

  9. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  10. Coupling passive sampling with in vitro bioassays and chemical analysis to understand combined effects of bioaccumulative chemicals in blood of marine turtles.

    PubMed

    Jin, Ling; Escher, Beate I; Limpus, Colin J; Gaus, Caroline

    2015-11-01

    Conventional target analysis of biological samples such as blood limits our ability to understand mixture effects of chemicals. This study aimed to establish a rapid passive sampling technique using the polymer polydimethylsiloxane (PDMS) for exhaustive extraction of mixtures of neutral organic chemicals accumulated in blood of green turtles, in preparation for screening in in vitro bioassays. We designed a PDMS-blood partitioning system based on the partition coefficients of chemicals between PDMS and major blood components. The sampling kinetics of hydrophobic test chemicals (polychlorinated dibenzo-p-dioxins; PCDDs) from blood into PDMS were reasonably fast reaching steady state in <96 h. The geometric mean of the measured PDMS-blood partition coefficients for PCDDs, polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) was 14 L blood kg PDMS(-1) and showed little variability (95% confidence interval from 8.4 to 29) across a wide range of hydrophobicity (logKow 5.7-8.3). The mass transfer of these chemicals from 5 mL blood into 0.94 g PDMS was 62-84%, which is similar to analytical recoveries in conventional solvent extraction methods. The validated method was applied to 15 blood samples from green turtles with known concentrations of PCDD/Fs, dioxin-like PCBs, PBDEs and organochlorine pesticides. The quantified chemicals explained most of the dioxin-like activity (69-98%), but less than 0.4% of the oxidative stress response. The results demonstrate the applicability of PDMS-based passive sampling to extract bioaccumulative chemicals from blood as well as the value of in vitro bioassays for capturing the combined effects of unknown and known chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Parental mediation of adolescent media use and demographic factors as predictors of Kenyan high school students' exposure to sexual content in television.

    PubMed

    Ngula, Kyalo wa; Mberia, Hellen K; Miller, Ann Neville

    2016-01-01

    Research in Western nations suggests that parents' involvement in their children's media use can make a difference in how adolescents select, process and respond to sexual television messages. Little or no published research has investigated this issue in sub-Saharan Africa, even though adolescents and young adults remain among the groups at highest risk for HIV transmission. This study investigated the relationship between Kenyan adolescents' level of exposure to sexual television content and their parents' mediation of their television use. A cluster sample of 427 Nairobi public high school students was surveyed regarding parental mediation of their media use and their intake of sexual television content. Co-viewing with opposite sex friends was associated with higher intake of sexual TV content. This relationship was stronger among boarding school students than among day school students. Parental mediation and co-viewing variables predicted three times as much variance among boarding than among day school students.

  12. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    PubMed

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2018-05-01

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.

  13. Parents’ and Professionals’ Perceptions on Causes and Treatment Options for Autism Spectrum Disorders (ASD) in a Multicultural Context on the Kenyan Coast

    PubMed Central

    Gona, Joseph K.; Rimba, Kenneth; Mapenzi, Rachel; Kihara, Michael

    2015-01-01

    Objective To explore parents’ and professionals’ perceived causes and treatment of Autism Spectrum Disorders (ASD) on the Kenyan Coast. Methods In-depth interviews and focus group discussions using guiding questions were utilized in data collection. One hundred and three participants, who included parents of children with ASD, special needs teachers, clinicians, and social workers from diverse cultural background, participated in this study. The interviews and focus groups were recorded, transcribed verbatim and then translated to English. Themes were generated using content analysis. Results Preternatural causes were mentioned and included evil spirits, witchcraft, and curses. Biomedical causes comprised infections, drug abuse, birth complications, malnutrition, and genetic related problems. Treatment varied from traditional and spiritual healing to modern treatment in health facilities, and included consultations with traditional healers, offering prayers to God, and visits to hospitals. Conclusions The results suggest that regardless of cultural backgrounds, people on the Kenyan Coast have similar views on perceived causes and treatment of ASD. These findings provide valuable conceptual understanding for professionals when planning and implementing community based rehabilitation interventions targeting children with ASD within a local context. PMID:26267668

  14. Small and cheap: accurate differential blood count with minimal sample volume by laser scanning cytometry (LSC)

    NASA Astrophysics Data System (ADS)

    Mittag, Anja; Lenz, Dominik; Smith, Paul J.; Pach, Susanne; Tarnok, Attila

    2005-04-01

    Aim: In patients, e.g. with congenital heart diseases, a differential blood count is needed for diagnosis. To this end by standard automatic analyzers 500 μl of blood is required from the patients. In case of newborns and infants this is a substantial volume, especially after operations associated with blood loss. Therefore, aim of this study was to develop a method to determine a differential blood picture with a substantially reduced specimen volume. Methods: To generate a differential blood picture 10 μl EDTA blood were mixed with 10 μl of a DRAQ5 solution (500μM, Biostatus) and 10 μl of an antibody mixture (CD45-FITC, CD14-PE, diluted with PBS). 20 μl of this cell suspension was filled into a Neubauer counting chamber. Due to the defined volume of the chamber it is possible to determine the cell count per volume. The trigger for leukocyte counting was set on DRAQ5 signal in order to be able to distinguish nucleated white blood cells from erythrocytes. Different leukocyte subsets could be distinguished due to the used fluorescence labeled antibodies. For erythrocyte counting cell suspension was diluted another 150 times. 20 μl of this dilution was analyzed in a microchamber by LSC with trigger set on forward scatter signal. Results: This method allows a substantial decrease of blood sample volume for generation of a differential blood picture (10 μl instead of 500μl). There was a high correlation between our method and the results of routine laboratory (r2=0.96, p<0.0001 n=40). For all parameters intra-assay variance was less than 7 %. Conclusions: In patients with low blood volume such as neonates and in critically ill infants every effort has to be taken to reduce the blood volume needed for diagnostics. With this method only 2% of standard sample volume is needed to generate a differential blood picture. Costs are below that of routine laboratory. We suggest this method to be established in paediatric cardiology for routine diagnostics and for

  15. Effect of storage conditions on the weight and appearance of dried blood spot samples on various cellulose-based substrates.

    PubMed

    Denniff, Philip; Spooner, Neil

    2010-11-01

    Before shipping and storage, dried blood spot (DBS) samples must be dried in order to protect the integrity of the spots. In this article, we examine the time required to dry blood spot samples and the effects of different environmental conditions on their integrity. Under ambient laboratory conditions, DBS samples on Whatman 903(®), FTA(®) and FTA(®) Elute substrates are dry within 90 min of spotting. An additional 5% of moisture is lost during subsequent storage with desiccant. When exposed to elevated conditions of temperature and relative humidity, the DBS samples absorb moisture. DBS samples on FTA lose this moisture on being returned to ambient conditions. DBS samples on 903 show no visible signs of deterioration when stored at elevated conditions. However, these conditions cause the DBS to diffuse through the FTA Elute substrate. Blood spots are dry within 90 min of spotting. However, the substrates examined behave differently when exposed to conditions of high relative humidity and temperature, in some cases resulting in the integrity of the substrate and DBS sample being compromised. It is recommended that these factors be investigated as part of method development and validation.

  16. Development and performance test of an online blood sampling system for determination of the arterial input function in rats.

    PubMed

    Roehrbacher, Friedrich; Bankstahl, Jens P; Bankstahl, Marion; Wanek, Thomas; Stanek, Johann; Sauberer, Michael; Muellauer, Julia; Schroettner, Thales; Langer, Oliver; Kuntner, Claudia

    2015-12-01

    For positron emission tomography (PET) kinetic modelling, an accurate determination of the arterial input function is required. In this study, a blood sampling system was developed and tested using different radiotracers in rats. The detector consists of pairs of lutetium yttrium oxyorthosilicate (LYSO) detectors, photomultiplier tubes and lead shield assembled within a steel casing working in coincidence mode. Rats were cannulated with microtubes in the femoral artery and vein for arterial blood sampling as well as administration of the PET tracers. Connected PTFE microtubes were centred between the LYSO crystals using a special holder. To enhance sensitivity, three layers with two coils were used. A flexible tube pump was used to ensure a constant blood flow. Performance of the detector was assessed with [(18)F]fludeoxyglucose (FDG), [(18)F]ciprofloxacin, (R)-[(11)C]verapamil, [(11)C]tariquidar, [(11)C]mephobarbital and [(11)C]MC113. Obtained input function curves were compared with manual samples drawn every 5 s during the first 3 min and further on at 5, 10, 20, 30, 40, 50 and 60 min after radiotracer injection. After manual sampling, an arterio/venous shunt was established. Shape and area-under-the-curve (AUC; Bq/μl*h) of the input functions were evaluated. The developed detector system provided an absolute sensitivity of 6.5%. Maximum peak values agreed well between manual samples and the detector with a mean difference of -0.4% ± 7.0% (max 12.0%, min -9.9%). AUC values also exhibited an excellent correlation (R = 0.996) between manual sampling and detector measurements with a mean difference of 9.3% ± 9.7% (max 24.1%, min -3.2%). The system was able to measure peak blood activity concentration levels of 110 to 2,000 Bq/μl which corresponds to injected activities from 5.5 to 100 MBq depending on the used radiotracer, applied volume and weight of the animal. This study demonstrates that the developed blood sampling system can be used for

  17. Environmental contaminants in Texas, USA, wetland reptiles: Evaluation using blood samples

    USGS Publications Warehouse

    Clark, D.R.; Bickham, J.W.; Baker, D.L.; Cowman, D.F.

    2000-01-01

    Four species of reptiles (diamondback water snake [Nerodia rhombifer], blotched water snake [N. erythrogaster], cottonmouth [Agkistrodon piscivorus], and red-eared slider [Trachemys scripta]) were collected at two contaminated and three reference sites in Texas, USA. Old River Slough has received intensive applications of agricultural chemicals since the 1950s. Municipal Lake received industrial arsenic wastes continuously from 1940 to 1993. Blood samples were analyzed for organochlorines, potentially toxic elements, genetic damage, and plasma cholinesterase (ChE). Dichlorodiphenyldichloroethylene (DDE) concentrations reached as high as 3.0 ppm (wet weight) in whole blood of a diamondback water snake at Old River Slough, a level probably roughly equivalent to the maximum concentration found in plasma of peregrine falcons (Falco peregrinus) in 1978 to 1979 when DDE peaked in this sensitive species. Possible impacts on diamondback water snakes are unknown, but at least one diamondback water snake was gravid when captured, indicating active reproduction. Arsenic was not found in red-eared sliders (only species sampled) from Municipal Lake. Red-eared sliders of both sexes at Old River Slough showed declining levels of ChE with increasing mass, suggesting a life-long decrease of ChE levels. Possible negative population consequences are unknown, but no evidence was found in body condition (mass relative to carapace length) that red-eared sliders at either contaminated site were harmed.

  18. Sociocultural and Victimization Factors That Impact Attitudes Toward Intimate Partner Violence Among Kenyan Women.

    PubMed

    Mugoya, George C T; Witte, Tricia H; Ernst, Kacey C

    2015-10-01

    This study investigates the association between acceptance of intimate partner violence (IPV) and reported IPV victimization among Kenyan women, taking into consideration select sociocultural factors that may also influence acceptance of IPV. Data from a nationally representative, cross-sectional, household survey conducted between November 2008 and February 2009 in Kenya were analyzed. Hierarchical multiple regression was conducted to estimate the effect of select sociodemographic characteristics and reported IPV victimization on acceptance of IPV. The results showed that while both sociodemographic characteristics and reported IPV victimization were significantly associated with IPV acceptance, sociocultural factors had a greater impact. Programs aimed at empowering women and culturally competent IPV prevention strategies may be the key elements to reducing IPV. © The Author(s) 2014.

  19. Antiretroviral Treatment Interruptions Induced by the Kenyan Postelection Crisis Are Associated With Virological Failure

    PubMed Central

    Kemboi, Emmanuel; Mambo, Fidelis; Rono, Mary; Injera, Wilfred; Delong, Allison; Schreier, Leeann; Kaloustian, Kara W.; Sidle, John; Buziba, Nathan; Kantor, Rami

    2014-01-01

    Background Antiretroviral treatment interruptions (TIs) cause suboptimal clinical outcomes. Data on TIs during social disruption are limited. Methods We determined effects of unplanned TIs after the 2007–2008 Kenyan postelection violence on virological failure, comparing viral load (VL) outcomes in HIV-infected adults with and without conflict-induced TI. Results Two hundred and one patients were enrolled, median 2.2 years after conflict and 4.3 years on treatment. Eighty-eight patients experienced conflict-related TIs and 113 received continuous treatment. After adjusting for preconflict CD4, patients with TIs were more likely to have detectable VL, VL >5,000 and VL >10,000. Conclusions Unplanned conflict-related TIs are associated with increased likelihood of virological failure. PMID:24047971

  20. Job strain and blood pressure in employed men and women: a pooled analysis of four northern italian population samples.

    PubMed

    Cesana, Giancarlo; Sega, Roberto; Ferrario, Marco; Chiodini, Paolo; Corrao, Giovanni; Mancia, Giuseppe

    2003-01-01

    The extent to which psychosocial stress concurs to raise blood pressure is still uncertain. Here the association between job strain and office blood pressure in a pooled analysis of four population samples from northern Italy is assessed. Four surveys assessing prevalence of major coronary risk factors were performed in 1986, 1990, 1991, and 1993 in area "Brianza" (Milan), a World Health Organization-MONItoring cardiovascular disease (WHO-MONICA) Project collaborating center. Ten year age- and gender-stratified independent samples were randomly recruited from the 25- to 64-year-old residents. The methods used to assess coronary risk factors strictly adhered to the MONICA manual, were kept constant, and underwent internal and external quality controls. Job strain was investigated through the administration to employed participants of a questionnaire derived from the Karasek model, assessing job demand/control latitude. Analysis was restricted to 25- to 54-year-old participants, untreated for hypertension (1799 men and 1010 women). Among men, there was a 3 mm Hg increase of systolic blood pressure (p<.001) moving from low to high strain job categories. This difference was independent from age, education, body mass index, alcohol intake, smoking habits, leisure time physical activity, and survey. No relevant differences among job strain categories were found in women and for diastolic blood pressure in both gender groups. These results carried out on a large population-based sample confirm previous findings obtained adopting ambulatory blood pressure measurements in more restricted samples of population or patients. Further research is needed to clarify the relationship between perceived work stress and blood pressure in women.

  1. Stable-Isotope Dilution HPLC-Electrospray Ionization Tandem Mass Spectrometry Method for Quantifying Hydroxyurea in Dried Blood Samples.

    PubMed

    Marahatta, Anu; Megaraj, Vandana; McGann, Patrick T; Ware, Russell E; Setchell, Kenneth D R

    2016-12-01

    Sickle cell anemia (SCA) is a life-threatening blood disorder characterized by the presence of sickle-shaped erythrocytes. Hydroxyurea is currently the only US Food and Drug Administration-approved treatment and there is a need for a convenient method to monitor compliance and hydroxyurea concentrations, especially in pediatric SCA patients. We describe a novel approach to the determination of hydroxyurea concentrations in dried whole blood collected on DMPK-C cards or volumetric absorptive microsampling (VAMS) devices. Hydroxyurea was quantified by electrospray ionization LC-MS/MS using [ 13 C 15 N 2 ]hydroxyurea as the internal standard. Calibrators were prepared in whole blood applied to DMPK-C cards or VAMS devices. Calibration curves for blood hydroxyurea measured from DMPK-C cards and VAMS devices were linear over the range 0.5-60 μg/mL. Interassay and intraassay CVs were <15% for blood collected by both methods, and the limit of detection was 5 ng/mL. Whole blood hydroxyurea was stable for up to 60 days on DMPK-C cards and VAMS devices when frozen at -20 °C or -80 °C. Whole blood hydroxyurea concentrations in samples collected on DMPK-C cards or VAMS devices from SCA patients were in close agreement. This tandem mass spectrometry method permits measurement of hydroxyurea concentrations in small volumes of dried blood applied to either DMPK-C cards or VAMS devices with comparable performance. This method for measuring hydroxyurea from dried blood permits the evaluation of therapeutic drug monitoring, individual pharmacokinetics, and medication adherence using heel/finger-prick samples from pediatric patients with SCA treated with hydroxyurea. © 2016 American Association for Clinical Chemistry.

  2. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    PubMed

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  3. Toxic heavy metals in human blood in relation to certain food and environmental samples in Kerala, South India.

    PubMed

    Jose, Anitha; Ray, Joseph George

    2018-03-01

    Toxic heavy metals such as arsenic (As), lead (Pb), and mercury (Hg) are systemic toxicants that are hazardous to human health. However, as these elements are increasing in the environment due to fast urbanization, industrialization, and chemicalized agricultural activities, accumulation of the same in human body anywhere in the world is quite interesting to global assessment of environment quality. In this connection, random examination of blood samples of human population in Kerala, South India, was carried out to assess the threat of heavy metal contamination to humans in this part of the globe, especially in relation to the amount of such metals in food and other environmental samples. Except pure vegetarians, people of Kerala consume rice as the staple food with a lot of fish. Therefore, the amount of these three heavy metals in drinking water, fish, rice, and paddy soils was done. Heavy metals in the blood were examined in relation to age, gender, and dietary habits such as frequency of fish eating or vegetarianism. Influence of dental amalgam fillings on blood mercury levels was also analyzed. Quantitative assessment of metals in samples was done by inductively coupled plasma-mass spectrometry (ICP-MS). The levels of arsenic, lead, and mercury were found well below the reference values, though diet seemed to pull them up as the amount of metals in blood showed significant differences between vegetarians and non-vegetarians. Evidence to the influence of dental amalgam fillings on blood mercury levels could not be established with the present samples.

  4. Evaluation of limited blood sampling population input approaches for kinetic quantification of [18F]fluorothymidine PET data.

    PubMed

    Contractor, Kaiyumars B; Kenny, Laura M; Coombes, Charles R; Turkheimer, Federico E; Aboagye, Eric O; Rosso, Lula

    2012-03-24

    Quantification of kinetic parameters of positron emission tomography (PET) imaging agents normally requires collecting arterial blood samples which is inconvenient for patients and difficult to implement in routine clinical practice. The aim of this study was to investigate whether a population-based input function (POP-IF) reliant on only a few individual discrete samples allows accurate estimates of tumour proliferation using [18F]fluorothymidine (FLT). Thirty-six historical FLT-PET data with concurrent arterial sampling were available for this study. A population average of baseline scans blood data was constructed using leave-one-out cross-validation for each scan and used in conjunction with individual blood samples. Three limited sampling protocols were investigated including, respectively, only seven (POP-IF7), five (POP-IF5) and three (POP-IF3) discrete samples of the historical dataset. Additionally, using the three-point protocol, we derived a POP-IF3M, the only input function which was not corrected for the fraction of radiolabelled metabolites present in blood. The kinetic parameter for net FLT retention at steady state, Ki, was derived using the modified Patlak plot and compared with the original full arterial set for validation. Small percentage differences in the area under the curve between all the POP-IFs and full arterial sampling IF was found over 60 min (4.2%-5.7%), while there were, as expected, larger differences in the peak position and peak height.A high correlation between Ki values calculated using the original arterial input function and all the population-derived IFs was observed (R2 = 0.85-0.98). The population-based input showed good intra-subject reproducibility of Ki values (R2 = 0.81-0.94) and good correlation (R2 = 0.60-0.85) with Ki-67. Input functions generated using these simplified protocols over scan duration of 60 min estimate net PET-FLT retention with reasonable accuracy.

  5. Detection of African swine fever virus DNA in blood samples stored on FTA cards from asymptomatic pigs in Mbeya region, Tanzania.

    PubMed

    Braae, U C; Johansen, M V; Ngowi, H A; Rasmussen, T B; Nielsen, J; Uttenthal, Å

    2015-02-01

    The aim of the study was to assess whether blood samples collected onto FTA(®) cards could be used in combination with real-time PCR for the detection of African swine fever virus (ASFV) DNA in samples from resource-poor settings under the assumption that asymptomatically (sub-clinically) infected pigs may be present. Blood samples were collected from clinically healthy pigs from Mbeya Region, Tanzania. The blood samples were stored on FTA(®) cards and analysed by real-time PCR assays in duplicate; three pigs had high levels of viral DNA (Ct values of 27-29), and three pigs had a low level of viral DNA (Ct 36-45). Four pigs were positive in one of the duplicate samples only, but clear products of the expected size were obtained when the reactions were analysed by gel electrophoresis. For comparison, blood samples from pigs experimentally infected with either a pathogenic (OURT T88/1) or a non-pathogenic (OURT T88/3) isolate of ASFV were collected, stored on FTA(®) cards and analysed in the same way. The blood from pigs infected with the OURT T88/1 isolate showed high levels of viral DNA (Ct 22-33), whereas infection with non-pathogenic OURT T88/3 isolate resulted in only low levels of viral DNA (Ct 39) in samples collected at 10-14 days after inoculation. © 2013 Blackwell Verlag GmbH.

  6. Optimization and application of octadecyl-modified monolithic silica for solid-phase extraction of drugs in whole blood samples.

    PubMed

    Namera, Akira; Saito, Takeshi; Ota, Shigenori; Miyazaki, Shota; Oikawa, Hiroshi; Murata, Kazuhiro; Nagao, Masataka

    2017-09-29

    Monolithic silica in MonoSpin for solid-phase extraction of drugs from whole blood samples was developed to facilitate high-throughput analysis. Monolithic silica of various pore sizes and octadecyl contents were synthesized, and their effects on recovery rates were evaluated. The silica monolith M18-200 (20μm through-pore size, 10.4nm mesopore size, and 17.3% carbon content) achieved the best recovery of the target analytes in whole blood samples. The extraction proceeded with centrifugal force at 1000rpm for 2min, and the eluate was directly injected into the liquid chromatography-mass spectrometry system without any tedious steps such as evaporation of extraction solvents. Under the optimized condition, low detection limits of 0.5-2.0ngmL -1 and calibration ranges up to 1000ngmL -1 were obtained. The recoveries of the target drugs in the whole blood were 76-108% with relative standard deviation of less than 14.3%. These results indicate that the developed method based on monolithic silica is convenient, highly efficient, and applicable for detecting drugs in whole blood samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Acetaminophen and meloxicam inhibit platelet aggregation and coagulation in blood samples from humans.

    PubMed

    Martini, Angela K; Rodriguez, Cassandra M; Cap, Andrew P; Martini, Wenjun Z; Dubick, Michael A

    2014-12-01

    Acetaminophen (Ace) and meloxicam (Mel) are the two types of analgesic and antipyretic medications. This study investigated the dose responses of acetaminophen and meloxicam on platelet aggregation and coagulation function in human blood samples. Blood samples were collected from six healthy humans and processed to make platelet-adjusted (100 × 10 cells/μl) blood samples. Acetaminophen (Tylenol, Q-PAP, 100 mg/ml) was added at the doses of 0 μg/ml (control), 214 μg/ml (the standard dose, 1 ×), 4 ×, 8 ×, 10 ×, 12 ×, 16 ×, and 20 ×. Similarly, meloxicam (Metacam, 5 mg/ml) was added at doses of 0 μg/ml (control), 2.85 μg/ml (the standard dose, 1 ×), 4 ×, 8 ×, 10 ×, 12 ×, 16 ×, and 20 ×. Fifteen minutes after the addition of acetaminophen and/or meloxicam, platelet aggregation was stimulated with collagen (2 μg/ml) or arachidonic acid (0.5 mmol/l) and assessed using a Chrono-Log 700 aggregometer. Coagulation function was assessed by prothrombin time (PT), activated partial thromboplastin time (aPTT), and using Rotem thrombelastogram. A robust inhibition by acetaminophen and/or meloxicam was observed in arachidonic acid-stimulated platelet aggregation starting at 1 × dose. Collagen-stimulated platelet aggregation was inhibited by ACE starting at 1 × (78 ± 10% of control), and by meloxicam starting at 4 × (72 ± 5% of control, both P < 0.05). The inhibitions by acetaminophen and meloxicam combined were similar to those by acetaminophen or meloxicam. aPTT was prolonged by meloxicam starting at 4 ×. No changes were observed in PT or any of Rotem measurements by acetaminophen and/or meloxicam. Acetaminophen and meloxicam compromised platelet aggregation and aPTT. Further effort is warranted to characterize the effects of acetaminophen and meloxicam on bleeding in vivo.

  8. Estimation of blood haemoglobin concentration using the HemoCue during caesarean section: the effect of sampling site.

    PubMed

    Richards, N A; Boyce, H; Yentis, S M

    2010-01-01

    Haemoglobin concentration measured using the HemoCue is accurate for capillary and venous/arterial blood, provided the recommended sampling method is strictly observed. Analysis of blood, particularly of capillary samples, using the HemoCue is useful during caesarean section. The toe might be preferred to the thumb since it is numb during neuraxial anaesthesia, but whether sampling at either site is accurate in this situation, given the cardiovascular effects of anaesthesia and pregnancy, is not known. We aimed to compare haemoglobin values measured in venous and capillary samples (toe and thumb) during caesarean section under neuraxial anaesthesia. Fifty healthy women having caesarean section under spinal or combined spinal-epidural anaesthesia were included. At the end of surgery, the great toe and thumb (non-i.v. fluid side) were lanced as recommended for a HemoCue reading. A venous blood sample (non-i.v. fluid side) was also taken and sent for formal laboratory measurement and tested with the HemoCue. Bland-Altman analysis was applied to the haemoglobin values. Bias (mean difference) and precision +/- 2 SD were respectively 0.2 +/-1.6 for laboratory vs. toe, 0.1 +/-1.8 for laboratory vs. thumb, and 0.2 +/-1.6 laboratory vs. venous. Our results suggest that in terms of accuracy, the two sites are equally suitable for use during caesarean section under neuraxial anaesthesia. Copyright 2009 Elsevier Ltd. All rights reserved.

  9. The impact of a national poverty reduction program on the characteristics of sex partners among Kenyan adolescents.

    PubMed

    Rosenberg, Molly; Pettifor, Audrey; Thirumurthy, Harsha; Halpern, Carolyn Tucker; Handa, Sudhanshu

    2014-02-01

    Cash transfer programs have the potential to prevent the spread of HIV, particularly among adolescents. One mechanism through which these programs may work is by influencing the characteristics of the people adolescents choose as sex partners. We examined the four-year impact of a Kenyan cash transfer program on partner age, partner enrollment in school, and transactional sex-based relationships among 684 adolescents. We found no significant impact of the program on partner characteristics overall, though estimates varied widely by gender, age, schooling, and economic status. Results highlight the importance of context in exploring the potential HIV preventive effects of cash transfers.

  10. Anesthesia and blood sampling of wild big brown bats (eptesicus fuscus) with an assessment of impacts on survival.

    PubMed

    Wimsatt, Jeffrey; O'Shea, Thomas J; Ellison, Laura E; Pearce, Roger D; Price, Valerie R

    2005-01-01

    We anesthetized and blood sampled wild big brown bats (Eptesicus fuscus) in Fort Collins, Colorado (USA) in 2001 and 2002 and assessed effects on survival. Inhalant anesthesia was delivered into a specially designed restraint and inhalation capsule that minimized handling and bite exposures. Bats were immobilized an average of 9.1+/-5.1 (SD) min (range 1-71, n=876); blood sample volumes averaged 58+/-12 microl (range 13-126, n=718). We randomly selected control (subject to multiple procedures before release) and treatment (control procedures plus inhalant anesthesia and 1% of body weight blood sampling) groups in 2002 to assess treatment effects on daily survival over a 14-day period for adult female and volant juvenile bats captured at maternity roosts in buildings. We monitored survival after release using passive integrated transponder tag detection hoops placed at openings to selected roosts. Annual return rates of bats sampled in 2001 were used to assess long-term outcomes. Comparison of 14-day maximum-likelihood daily survival estimates from control (86 adult females, 92 volant juveniles) and treated bats (187 adult females, 87 volant juveniles) indicated no adverse effect from anesthesia and blood sampling (juveniles: chi2=22.22, df=27, P>0.05; adults: chi2=9.72, df=18, P>0.05). One-year return rates were similar among adult female controls (81%, n=72, 95% confidence interval [CI]=70-91%), females treated once (82%, n=276, 95% CI=81-84%), and females treated twice (84%, n=50, 95% CI=74-94%). Lack of an effect was also noted in 1-yr return rates of juvenile female controls (55%, n=29, 95% CI=37-73%), juveniles treated once (66%, n=113, 95% CI=58-75%), and juveniles treated twice (71%, n=17, 95% CI=49-92%). These data suggest that anesthesia and blood sampling for health monitoring did not measurably affect survival of adult female and volant juvenile big brown bats.

  11. Anesthesia and blood sampling of wild big brown bats (Eptesicus fuscus) with an assessment of impacts on survival

    USGS Publications Warehouse

    Wimsatt, J.; O'Shea, T.J.; Ellison, L.E.; Pearce, R.D.; Price, V.R.

    2005-01-01

    We anesthetized and blood sampled wild big brown bats (Eptesicus fuscus) in Fort Collins, Colorado (USA) in 2001 and 2002 and assessed effects on survival. Inhalant anesthesia was delivered into a specially designed restraint and inhalation capsule that minimized handling and bite exposures. Bats were immobilized an average of 9.1±5.1 (SD) min (range 1–71, n=876); blood sample volumes averaged 58±12 μl (range 13–126, n=718). We randomly selected control (subject to multiple procedures before release) and treatment (control procedures plus inhalant anesthesia and 1% of body weight blood sampling) groups in 2002 to assess treatment effects on daily survival over a 14-day period for adult female and volant juvenile bats captured at maternity roosts in buildings. We monitored survival after release using passive integrated transponder tag detection hoops placed at openings to selected roosts. Annual return rates of bats sampled in 2001 were used to assess long-term outcomes. Comparison of 14-day maximum-likelihood daily survival estimates from control (86 adult females, 92 volant juveniles) and treated bats (187 adult females, 87 volant juveniles) indicated no adverse effect from anesthesia and blood sampling (juveniles: χ2=22.22, df=27, P>0.05; adults: χ2=9.72, df=18, P>0.05). One-year return rates were similar among adult female controls (81%, n=72, 95% confidence interval [CI] =70–91%), females treated once (82%, n=276, 95% CI=81–84%), and females treated twice (84%, n=50, 95% CI=74–94%). Lack of an effect was also noted in 1-yr return rates of juvenile female controls (55%, n=29, 95% CI=37–73%), juveniles treated once (66%, n=113, 95% CI=58–75%), and juveniles treated twice (71%, n=17, 95% CI=49–92%). These data suggest that anesthesia and blood sampling for health monitoring did not measurably affect survival of adult female and volant juvenile big brown bats.

  12. Evaluation of the human immunodeficiency virus type 1 and 2 antibodies detection in dried whole blood spots (DBS) samples.

    PubMed

    Castro, Andréa Cauduro de; Borges, Luiz Gustavo dos Anjos; Souza, Ricardo da Silva de; Grudzinski, Melina; D'Azevedo, Pedro Alves

    2008-01-01

    Human Immunodeficiency Virus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and immunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS-Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 degrees C, -20 degrees C and -70 degrees C, while the second was composed of two negative and three positive samples stored at 37 degrees C (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.

  13. The relationship between blood and muscle samples to monitor for residues of the antibiotic enrofloxacin in chickens.

    PubMed

    Reyes-Herrera, I; Schneider, M J; Blore, P J; Donoghue, D J

    2011-02-01

    In 2005, the US Food and Drug Administration withdrew approval for use of enrofloxacin in poultry, thus effectively imposing zero tolerance for residues of this antibiotic in poultry. Conventional residue monitoring for most antibiotics, including enrofloxacin, involves removing poultry carcasses from the processing line and collecting muscle tissues for analysis. Because of the loss of valuable edible products and the difficulties and expense of sampling all the carcasses, only a small portion of carcasses are tested for violative residues. Unlike muscle tissue, blood is readily available from all birds at the beginning of processing and may be used to screen for illegal residues in all poultry carcasses. It is unknown, however, if enrofloxacin concentrations in blood are predictive of muscle concentrations. In an effort to evaluate this relationship, 156 broiler chickens, 5 wk of age, were dosed with either 25 or 50 µg/mL of enrofloxacin for 3 or 7 d, respectively, in the drinking water. Blood and muscle samples were collected at 0, 1, 3, 6, 12, and 24 h (n = 6 birds/group) during the first dosing day, every 48 h during the dosing period, and every 12 h during the withdrawal period for up to 60 h after withdrawal. Enrofloxacin residues were determined in all blood and tissue samples during the dosing periods and in most of the withdrawal period for both doses. These results support the potential to use blood to screen for illegal enrofloxacin residues in edible poultry tissues in an effort to protect the human food supply.

  14. Simplifying sampling for African swine fever surveillance: Assessment of antibody and pathogen detection from blood swabs.

    PubMed

    Carlson, J; Zani, L; Schwaiger, T; Nurmoja, I; Viltrop, A; Vilem, A; Beer, M; Blome, S

    2018-02-01

    African swine fever (ASF) is a notifiable disease with serious socio-economic consequences that has been present in wild boar in the Baltic States and Poland since 2014. An introduction of ASF is usually accompanied by increased mortality, making fallen wild boar and hunted animals with signs of disease the main target for early warning and passive surveillance. It is difficult, however, to encourage hunters and foresters to report and take samples from these cases. A pragmatic and easy sampling approach with quick-drying swabs could facilitate this. In this study, we further evaluated the use of dry blood swabs for the detection of ASFV antibody and genome with samples from animal trials and diagnostic submissions (blood, bone and organs) from Estonia. Compared to serum samples, dried blood swabs yielded 93.1% (95% confidence interval: [83.3, 98.1]) sensitivity and 100% [95.9, 100.0] specificity in a commercial ASFV antibody ELISA. Similarly, the swabs gave a sensitivity of 98.9% [93.4, 100.0] and a specificity of 98.1% [90.1, 100.0] for genome detection by a standard ASFV p72 qPCR when compared to EDTA blood. The same swabs were tested in a VP72-antibody lateral flow device, with a sensitivity of 94.7% [85.4, 98.9] and specificity of 96.1% [89.0, 99.2] compared to the serum ELISA. When GenoTube samples tested in ELISA and LFD were compared, the sensitivity was 96.3% [87.3, 99.5] and the specificity was 93.8% [86.0, 97.9]. This study demonstrates reliable detection of ASFV antibody and genome from swabs. A field test of the swabs with decomposed wild boar carcasses in an endemic area in Estonia also gave promising results. Thus, this technique is a practical approach for surveillance of ASF in both free and endemic areas. © 2017 Blackwell Verlag GmbH.

  15. Capillary refill: prognostic value in Kenyan children

    PubMed Central

    Pamba, A; Maitland, K

    2004-01-01

    Aims: To determine whether delayed capillary refill time (>3 seconds) is a useful prognostic indicator in Kenyan children admitted to hospital. Methods: A total of 4160 children admitted to Kilifi District Hospital with malaria, malarial anaemia, acute respiratory tract infection (ARI), severe anaemia (haemoglobin <50 g/l), gastroenteritis, malnutrition, meningitis, or septicaemia were studied. Results: Overall, delayed capillary refill time (dCRT), present in 346/4160 (8%) of the children, was significantly more common in fatal cases (44/189, 23%) than survivors (7.5%), and had useful prognostic value. In children admitted with malaria, gastroenteritis, or malnutrition, likelihood ratio tests suggested that dCRT was useful in identifying high risk groups for mortality, but its prognostic value in anaemia, ARI, and sepsis was unclear due to low case fatality or limited numbers. The severity features of impaired consciousness and deep breathing were significantly associated both with the presence of dCRT and fatal outcome. In children, with either of these severity features, a less stringent value of dCRT(>2 s) identified 50% of children with hypotension (systolic BP <2SD) and 40% of those requiring volume resuscitation (for metabolic acidosis). Conclusions: Although CRT is a simple bedside test, which may be used in resource poor settings as a guide to the circulatory status, dCRT should not be relied on in the absence of other features of severity. In non-severe disease, the additional presence of hypoxia, a moderately raised creatinine (>80 µmol/l), or a raised white cell count should prompt the need for fluid expansion. PMID:15383440

  16. Anti-glucagon-like peptide-1 immunoreactivity in samples of blood and ileum obtained from neonatal and adult alpacas.

    PubMed

    Smith, Courtney C; Cebra, Christopher K; Heidel, Jerry R; Stang, Bernadette V

    2013-11-01

    To compare numbers of L cells in intestinal samples and blood concentrations of glucagon-like peptide (GLP)-1 between neonatal and mature alpacas. Intestinal samples from carcasses of 4 suckling crias and 4 postweaning alpacas for immunohistochemical analysis and blood samples from 32 suckling crias and 19 healthy adult alpacas for an ELISA. Immunohistochemical staining was conducted in accordance with Oregon State University Veterinary Diagnostic Laboratory standard procedures with a rabbit polyclonal anti-GLP-1 primary antibody. Stained cells with staining results in ileal tissue were counted in 20 fields by 2 investigators, and the mean value was calculated. For quantification of GLP-1 concentrations, blood samples were collected into tubes containing a dipeptidyl peptidase-4 inhibitor. Plasma samples were tested in duplicate with a commercial GLP-1 ELISA validated for use in alpacas. Counts of stained cells (mean ± SD, 50 ± 18 cells) and plasma GLP-1 concentrations (median, 0.086 ng/mL; interquartile range, 0.061 to 0.144 ng/mL) were higher for suckling alpacas than for postsuckling alpacas (stained cells, 26 ± 4 cells; plasma GLP-1 concentration, median, 0.034 ng/mL; interquartile range, 0.015 to 0.048 ng/mL). Older alpacas had lower numbers of L cells in intestinal tissues and lower blood concentrations of GLP-1 than those in neonates. These findings suggested that there may be a decrease in the contribution of GLP-1 to insulin production in adult alpacas, compared with the contribution in neonates.

  17. Comparison of two real-time PCR assays for the detection of malaria parasites from hemolytic blood samples - Short communication.

    PubMed

    Hagen, Ralf Matthias; Hinz, Rebecca; Tannich, Egbert; Frickmann, Hagen

    2015-06-01

    We compared the performance of an in-house and a commercial malaria polymerase chain reaction (PCR) assay using freeze-thawed hemolytic blood samples. A total of 116 freeze-thawed ethylenediamine tetraacetic acid (EDTA) blood samples of patients with suspicion of malaria were analyzed by an in-house as well as by a commercially available real-time PCR. Concordant malaria negative PCR results were reported for 39 samples and malaria-positive PCR results for 67 samples. The in-house assay further detected one case of Plasmodium falciparum infection, which was negative in the commercial assay as well as five cases of P. falciparum malaria and three cases of Plasmodium vivax malaria, which showed sample inhibition in the commercial assay. The commercial malaria assay was positive in spite of a negative in-house PCR result in one case. In all concordant results, cycle threshold values of P. falciparum-positive samples were lower in the commercial PCR than in the in-house assay. Although Ct values of the commercial PCR kit suggest higher sensitivity in case of concordant results, it is prone to inhibition if it is applied to hemolytic freeze-thawed blood samples. The number of misidentifications was, however, identical for both real-time PCR assays.

  18. Do the venous blood samples replicate malaria parasite densities found in capillary blood? A field study performed in naturally-infected asymptomatic children in Cameroon.

    PubMed

    Sandeu, Maurice M; Bayibéki, Albert N; Tchioffo, Majoline T; Abate, Luc; Gimonneau, Geoffrey; Awono-Ambéné, Parfait H; Nsango, Sandrine E; Diallo, Diadier; Berry, Antoine; Texier, Gaétan; Morlais, Isabelle

    2017-08-17

    The measure of new drug- or vaccine-based approaches for malaria control is based on direct membrane feeding assays (DMFAs) where gametocyte-infected blood samples are offered to mosquitoes through an artificial feeder system. Gametocyte donors are identified by the microscopic detection and quantification of malaria blood stages on blood films prepared using either capillary or venous blood. However, parasites are known to sequester in the microvasculature and this phenomenon may alter accurate detection of parasites in blood films. The blood source may then impact the success of mosquito feeding experiments and investigations are needed for the implementation of DMFAs under natural conditions. Thick blood smears were prepared from blood obtained from asymptomatic children attending primary schools in the vicinity of Mfou (Cameroon) over four transmission seasons. Parasite densities were determined microscopically from capillary and venous blood for 137 naturally-infected gametocyte carriers. The effect of the blood source on gametocyte and asexual stage densities was then assessed by fitting cumulative link mixed models (CLMM). DMFAs were performed to compare the infectiousness of gametocytes from the different blood sources to mosquitoes. Prevalence of Plasmodium falciparum asexual stages among asymptomatic children aged from 4 to 15 years was 51.8% (2116/4087). The overall prevalence of P. falciparum gametocyte carriage was 8.9% and varied from one school to another. No difference in the density of gametocyte and asexual stages was found between capillary and venous blood. Attempts to perform DMFAs with capillary blood failed. Plasmodium falciparum malaria parasite densities do not differ between capillary and venous blood in asymptomatic subjects for both gametocyte and trophozoite stages. This finding suggests that the blood source should not interfere with transmission efficiency in DMFAs.

  19. CYP3A5 genotype and its impact on vincristine pharmacokinetics and development of neuropathy in Kenyan children with cancer.

    PubMed

    Skiles, Jodi L; Chiang, ChienWei; Li, Claire H; Martin, Steve; Smith, Ellen L; Olbara, Gilbert; Jones, David R; Vik, Terry A; Mostert, Saskia; Abbink, Floor; Kaspers, Gertjan J; Li, Lang; Njuguna, Festus; Sajdyk, Tammy J; Renbarger, Jamie L

    2018-03-01

    Vincristine (VCR) is a critical part of treatment in pediatric malignancies and is associated with dose-dependent peripheral neuropathy (vincristine-induced peripheral neuropathy [VIPN]). Our previous findings show VCR metabolism is regulated by the CYP3A5 gene. Individuals who are low CYP3A5 expressers metabolize VCR slower and experience more severe VIPN as compared to high expressers. Preliminary observations suggest that Caucasians experience more severe VIPN as compared to nonCaucasians. Kenyan children with cancer who were undergoing treatment including VCR were recruited for a prospective cohort study. Patients received IV VCR 2 mg/m 2 /dose with a maximum dose of 2.5 mg as part of standard treatment protocols. VCR pharmacokinetics (PK) sampling was collected via dried blood spot cards and genotyping was conducted for common functional variants in CYP3A5, multi-drug resistance 1 (MDR1), and microtubule-associated protein tau (MAPT). VIPN was assessed using five neuropathy tools. The majority of subjects (91%) were CYP3A5 high-expresser genotype. CYP3A5 low-expresser genotype subjects had a significantly higher dose and body surface area normalized area under the curve than CYP3A5 high-expresser genotype subjects (0.28 ± 0.15 hr·m 2 /l vs. 0.15 ± 0.011 hr·m 2 /l, P = 0.027). Regardless of which assessment tool was utilized, minimal neuropathy was detected in this cohort. There was no difference in the presence or severity of neuropathy assessed between CYP3A5 high- and low-expresser genotype groups. Genetic factors are associated with VCR PK. Due to the minimal neuropathy observed in this cohort, there was no demonstrable association between genetic factors or VCR PK with development of VIPN. Further studies are needed to determine the role of genetic factors in optimizing dosing of VCR for maximal benefit. © 2017 Wiley Periodicals, Inc.

  20. Willingness to donate blood samples for genetic research: a survey from a community in Singapore.

    PubMed

    Wong, M L; Chia, K S; Yam, W M; Teodoro, G R; Lau, K W

    2004-01-01

    Studies on the public's willingness to donate blood specimens for genetic research are few and are conducted mainly among Western countries. Little is known about the Asian community's willingness to participate in genetic research. A community-based survey was conducted on 548 adult Singaporeans to examine their willingness to donate blood samples for genetic research and its associated factors. The response rate was 70.3%. About 49.3% (95% CI, 45.1-53.5%) were willing to donate blood for genetic research. In the multivariable Cox regression analysis, willingness was significantly associated with belief in the benefits of genetic research; intention to participate in government studies; having no fear of pain, blood, injections, and needles; and non-concern about the loss of confidentiality. Reasons against donating blood were fear of pain, blood, injections, and needles (38.1%); no self-benefits (24.8%); fear of finding out about having a disease (22.3%); fear of discrimination (18.7%); and concerns about weakness (15.1%) and weight gain (9.4%). Public education programs to promote participation in genetic research should stress its benefits and address people's fears and concerns.

  1. Knowledge of Good Blood Culture Sampling Practice among Healthcare Staffs in An Emergency Department - Are We Getting It Right?

    PubMed

    Chew, K S; Mohd Hashairi, F; Jusoh, A F; Aziz, A A; Nik Hisamuddin, N A R; Siti Asma, H

    2013-08-01

    Although a vital test, blood culture is often plagued with the problem of contamination and false results, especially in a chaotic emergency department setting. The objectives of this pilot study is to find out the level of understanding among healthcare staffs in emergency department, Hospital Universiti Sains Malaysia (HUSM) regarding good blood culture sampling practice. All healthcare staffs in emergency department, HUSM who consented to this study were given a set of selfadministered anonymous questionnaire to fill. More than half (53.1%) of the 64 participants are emergency medicine residents. Majority of them (75%) have been working in the emergency medicine, HUSM for more than 2 years. More than half of them were able to answer correctly the amount of blood volume needed for culture in adult and pediatric patients. When asked what are the factors required to improve the true yield as well as to reduce the risk of culture contamination, the four commonest answers given were observing proper aseptic technique during blood sampling, donning sterile glove, proper hand scrubbing as well as ensuring the sterility of the equipments. This study suggests that there is a lack of proper knowledge of good blood culture sampling practice among our healthcare staffs in emergency department.

  2. Absorption Peaks: α, β, γ and Their Covariance with Age and Hemoglobin in Human Blood Samples Using Photoacoustic Spectroscopy

    NASA Astrophysics Data System (ADS)

    González-Domínguez, J. L.; Hernández-Aguilar, C.; Domínguez-Pacheco, F. A.; Martínez-Ortiz, E.; Cruz-Orea, A.; Sánchez-Sinencio, F.

    2012-11-01

    This study reports the absorption peaks α, β, γ in the Soret band of photoacoustic (PA) signals and their covariance with age and hemoglobin in human blood samples through PA spectroscopy. Samples were taken randomly from a masculine population grouped in three categories according to age: infants, young adults, and senior adults. Samples were prepared with two drops of blood from a 0.5 mL insulin syringe with a needle gauge 31G over 5 mm circles of filter paper. It was observed that the PA signal, the amplitude as a function of the wavelength, has a behavior as that reported for human blood for the three absorption peaks α, β, γ. In particular, the ratio γ/ β is due to electronic transitions associated with charge-transfer interactions of iron orbitals with the ligand states. Through an evaluation of optical absorption peaks in blood samples and their covariance with age and hemoglobin concentration, a relationship was found for the ratio peaks γ/ β and γ/ α with such parameters. Specifically, a negative covariance in the Soret band of the ratio peaks γ/ β and γ/ α with respect to both age and hemoglobin was found. This showed a tendency in their behavior. Further experiments of different populations may corroborate these conclusions.

  3. Cleaning the IceMole: collection of englacial samples from Blood Falls, Antarctica

    NASA Astrophysics Data System (ADS)

    Mikucki, J.; Digel, I.; Chua, M.; Davis, J.; Ghosh, D.; Lyons, W. B.; Welch, K. A.; Purcell, A.; Francke, G.; Feldmann, M.; Espe, C.; Heinen, D.; Dachwald, B.; Kowalski, J.; Tulaczyk, S. M.

    2016-12-01

    The Minimally Invasive Direct Glacial Access project (MIDGE) used a maneuverable thermoelectric melting probe called the IceMole to collect the first englacial samples of brine from Blood Falls, Antarctica. In order to maintain the scientific integrity of samples collected and minimize impact to this specially protected ecosystem, microbial and chemical contamination of the IceMole needed to be minimized. Guidelines have been established for research in Antarctic subglacial systems by the scientific and regulatory community and have been detailed by the "Code of Conduct for the Exploration and Research of Subglacial Aquatic Environments" put forth by the Scientific Committee on Antarctic Research (SCAR) Action Group, and was submitted to the Antarctic Treaty System. This Code of Conduct (CoC) recognizes the ecological importance and pristine nature of subglacial habitats and recommends a path forward towards clean exploration. Similarly, the US and European space agencies (NASA and ESA) have detailed instrument preparation protocols for the exploration of icy worlds in our solar system for planetary protection. Given the synergistic aims of these two groups we have adopted protocols from both subglacial and space exploration approaches. Here we present our approach to cleaning the IceMole in the field and report on ability to reduce the bioload inherent on the melter. Specifically our protocol reduced the exterior bio-load by an order of magnitude, to levels common in most clean rooms, and 1-3 orders of magnitude below that of Taylor Glacier ice surrounding Blood Falls. Our results indicate that the collection of englacial samples for microbiological analysis is feasible with melting probes.

  4. Comparison of PCR-Based Diagnosis with Centrifuged-Based Enrichment Method for Detection of Borrelia persica in Animal Blood Samples.

    PubMed

    Naddaf, S R; Kishdehi, M; Siavashi, Mr

    2011-01-01

    The mainstay of diagnosis of relapsing fever (RF) is demonstration of the spirochetes in Giemsa-stained thick blood smears, but during non fever periods the bacteria are very scanty and rarely detected in blood smears by microscopy. This study is aimed to evaluate the sensitivity of different methods developed for detection of low-grade spirochetemia. Animal blood samples with low degrees of spirochetemia were tested with two PCRs and a nested PCR targeting flaB, GlpQ, and rrs genes. Also, a centrifuged-based enrichment method and Giemsa staining were performed on blood samples with various degrees of spirochetemia. The flaB-PCR and nested rrs-PCR turned positive with various degrees of spirochetemia including the blood samples that turned negative with dark-field microscopy. The GlpQ-PCR was positive as far as at least one spirochete was seen in 5-10 microscopic fields. The sensitivity of GlpQ-PCR increased when DNA from Buffy Coat Layer (BCL) was used as template. The centrifuged-based enrichment method turned positive with as low concentration as 50 bacteria/ml blood, while Giemsa thick staining detected bacteria with concentrations ≥ 25000 bacteria/ml. Centrifuged-based enrichment method appeared as much as 500-fold more sensitive than thick smears, which makes it even superior to some PCR assays. Due to simplicity and minimal laboratory requirements, this method can be considered a valuable tool for diagnosis of RF in rural health centers.

  5. Development of an animal-borne blood sample collection device and its deployment for the determination of cardiovascular and stress hormones in phocid seals.

    PubMed

    Takei, Yoshio; Suzuki, Ippei; Wong, Marty K S; Milne, Ryan; Moss, Simon; Sato, Katsufumi; Hall, Ailsa

    2016-10-01

    An animal-borne blood sampler with data-logging functions was developed for phocid seals, which collected two blood samples for the comparison of endocrinological/biochemical parameters under two different conditions. The sampler can be triggered by preset hydrostatic pressure, acceleration (descending or ascending), temperature, and time, and also manually by light. The sampling was reliable with 39/50 (78%) successful attempts to collect blood samples. Contamination of fluids in the tubing to the next blood sample was <1%, following the prior clearance of the tubing to a waste syringe. In captive harbor seals ( Phoca vitulina ), the automated blood-sampling method was less stressful than direct blood withdrawal, as evidenced by lower levels of stress hormones ( P < 0.05 for ACTH and P = 0.078 for cortisol). HPLC analyses showed that both cortisol and cortisone were circulating in seal blood. Using the sampler, plasma levels of cardiovascular hormones, atrial natriuretic peptide (ANP), AVP, and ANG II were compared in grey seals ( Halichoerus grypus ), between samples collected when the animals were on land and in the water. HPLC analyses determined that [Met 12 ] ANP (1-28) and various forms of angiotensins (ANG II, III, and IV) were circulating in seal blood. Although water immersion profoundly changes the plasma levels of cardiovascular hormones in terrestrial mammals, there were only tendencies toward an increase in ANP ( P = 0.069) and a decrease in AVP ( P = 0.074) in the seals. These results suggest that cardiovascular regulation in phocid seals may have undergone adaptation during evolution of the carnivore to a semiaquatic lifestyle. Copyright © 2016 the American Physiological Society.

  6. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    PubMed

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, P<0.05). This was the first study to determine the sampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  7. Racism and ambulatory blood pressure in a community sample.

    PubMed

    Brondolo, Elizabeth; Libby, Daniel J; Denton, Ellen-Ge; Thompson, Shola; Beatty, Danielle L; Schwartz, Joseph; Sweeney, Monica; Tobin, Jonathan N; Cassells, Andrea; Pickering, Thomas G; Gerin, William

    2008-01-01

    Racism has been identified as a psychosocial stressor that may contribute to disparities in the prevalence of cardiovascular disease. The goal of the present article was to investigate the relationship of perceived racism to ambulatory blood pressure (ABP) in a sample of American-born Blacks and Latinos. Participants included English-speaking Black or Latino(a) adults between the ages of 24 and 65. They completed daily mood diaries and measures of perceived racism, socioeconomic status, and hostility. Participants were outfitted with ABP monitors; 357 provided data on waking hours only, and 245 provided data on both waking and nocturnal ABP. Perceived racism was positively associated with nocturnal ABP even when controlling for personality factors and socioeconomic status. The results suggest that racism may influence cardiovascular disease risk through its effects on nocturnal BP recovery.

  8. Value of PCR for Detection of Toxoplasma gondii in Aqueous Humor and Blood Samples from Immunocompetent Patients with Ocular Toxoplasmosis

    PubMed Central

    Bou, Germán; Figueroa, Marta S.; Martí-Belda, Paloma; Navas, Enrique; Guerrero, Antonio

    1999-01-01

    Toxoplasma gondii infection is an important cause of chorioretinitis in the United States and Europe. Most cases of Toxoplasma chorioretinitis result from congenital infection. Patients are often asymptomatic during life, with a peak incidence of symptomatic illness in the second and third decades of life. Diagnosis is mainly supported by ophthalmological examination and a good response to installed therapy. However, establishment of a diagnosis by ophthalmological examination alone can be difficult in some cases. To determine the diagnostic value of PCR for the detection of T. gondii, 56 blood and 56 aqueous humor samples from 56 immunocompetent patients were examined. Fifteen patients with a diagnosis of ocular toxoplasmosis had increased serum anti-T. gondii immunoglobulin G levels but were negative for anti-T. gondii immunoglobulin M (group 1), and 41 patients were used as controls (group 2). Samples were taken before antiparasitic therapy was initiated, and only one blood sample and one aqueous humor sample were obtained for each patient. Single nested PCRs and Southern blot hybridization were performed with DNA extracted from these samples. The results obtained showed sensitivity and specificity values of 53.3 and 83%, respectively. Interestingly, among all patients with ocular toxoplasmosis, a positive PCR result with the aqueous humor sample was accompanied by a positive PCR result with the blood sample. This result suggests that ocular toxoplasmosis should not be considered a local event, as PCR testing of blood samples from patients with ocular toxoplasmosis yielded the same result as PCR testing of aqueous humor samples. PCR testing may be useful for discriminating between ocular toxoplasmosis and other ocular diseases, and also can avoid the problems associated with ocular puncture. PMID:10523535

  9. [Characteristic of sample banks isolated from EDTA-blood by sedimentation method].

    PubMed

    Chen, Zhi-bin; Lin, Qin; Ma, Chang-hua; Liu, Kai-ning; Meng, Huan-xin

    2014-02-18

    To assess the characteristics of establishing the different sample banks of plasma, leukocytes and DNA by sedimentation method of isolating from ethylene diamine tetraacetic acid(EDTA)-blood and to clarify the sedimentation method of leukocyte isolation and plasma volume by comparative data and recommended procedures for applicability. In the study, 29 EDTA-bloods were obtained, the total amounts of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes in the EDTA-blood detected as a control group and then assigned equally into 4 EP tubes with 1 mL EDTA-blood per tube as 4 test groups, then the 4 tubes were placed with the EDTA-blood at room temperature and the plasma layers were isolated at 0.5, 1, 2 and 3 h, receptively. The total amount of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes were detected by automated hematology analyzer at the clinical laboratory. The volume of the plasma was also measured at the same time. The plasma volume at 0.5 h [(241.72 ± 101.52)μL] was substantially lower than those at 1 h[(317.24 ± 97.50)μL], at 2 h[(371.03 ± 91.66)μL], and at 3 h [(408.97 ± 97.43)μL] , P < 0.05. The plasma volume at 1 h was substantially lower than those at 2 h and 3 h (P < 0.05). The total amount of leukocytes in the plasma layer at 0.5 h (2.50 × 10(6) ± 1.48 × 10(6)) group was substantially higher than the amount of 2 or 3 h groups respectively (1.47 × 10(6) ± 7.19 × 105,1.21 × 10(6) ± 7.41 × 105), P < 0.05. Significant difference was not found between 0.5 h group and 1 h group (2.29 × 10(6)± 1.17 × 10(6)), P > 0.05. The total amount of leukocytes in the plasma layer in 1 h group was substantially higher than that in 2 h and 3 h groups (P < 0.05). There was no significant difference between 3 h group and 2 h group (P > 0.05). The total amount of leukocytes in the plasma layer of the 4 test groups was substantially lower than that in the control group (P < 0.05). The percentage of

  10. Sample preparation method influences direct identification of anaerobic bacteria from positive blood culture bottles using MALDI-TOF MS.

    PubMed

    Jeverica, Samo; Nagy, Elisabeth; Mueller-Premru, Manica; Papst, Lea

    2018-05-15

    Rapid detection and identification of anaerobic bacteria from blood is important to adjust antimicrobial therapy by including antibiotics with activity against anaerobic bacteria. Limited data is available about direct identification of anaerobes from positive blood culture bottles using MALDI-TOF mass spectrometry (MS). In this study, we evaluated the performance of two sample preparation protocols for direct identification of anaerobes from positive blood culture bottles, the MALDI Sepsityper kit (Sepsityper) and the in-house saponin (saponin) method. Additionally, we compared two blood culture bottle types designed to support the growth of anaerobic bacteria, the BacT/ALERT-FN Plus (FN Plus) and the BACTEC-Lytic (Lytic), and their influence on direct identification. A selection of 30 anaerobe strains belonging to 22 different anaerobic species (11 reference strains and 19 clinical isolates) were inoculated to 2 blood culture bottle types in duplicate. In total, 120 bottles were inoculated and 99.2% (n = 119) signalled growth within 5 days of incubation. The Sepsityper method correctly identified 56.3% (n = 67) of anaerobes, while the saponin method correctly identified 84.9% (n = 101) of anaerobes with at least log(score) ≥1.6 (low confidence correct identification), (p < 0.001). Gram negative anaerobes were better identified with the saponin method (100% vs. 46.5%; p < 0.001), while Gram positive anaerobes were better identified with the Sepsityper method (70.8% vs. 62.5%; p = 0.454). Average log(score) values among only those isolates that were correctly identified simultaneously by both sample preparation methods were 2.119 and 2.029 in favour of the Sepsityper method, (p = 0.019). The inoculated bottle type didn't influence the performance of the two sample preparation methods. We confirmed that direct identification from positive blood culture bottles with MALDI-TOF MS is reliable for anaerobic bacteria. However, the results

  11. Blood pressure associated with sleep-disordered breathing in a population sample of children.

    PubMed

    Bixler, Edward O; Vgontzas, Alexandros N; Lin, Hung-Mo; Liao, Duanping; Calhoun, Susan; Fedok, Fred; Vlasic, Vukmir; Graff, Gavin

    2008-11-01

    The current criteria for sleep-disordered breathing (SDB) in children are not based on a clinically relevant outcome. The purpose of this study was to assess the association of blood pressure with SDB in a random sample of the local elementary school children (kindergarten through grade 5) using a 2-phased strategy. During phase 1, a brief questionnaire was completed for all of the children (N=5740) with a response rate of 78.5%. During phase 2, 700 randomly selected children from phase 1 with a response rate of 70.0% were assessed with a full polysomnograph and a history/physical, including an ECG; ear, nose, and throat; and pulmonary evaluation. We observed a significantly elevated systolic blood pressure associated with the apnea hypopnea index (AHI): AHI >or=1 (2.9 mm Hg); AHI >or=3 (7.1 mm Hg); and AHI >or=5 (12.9 mm Hg). The SDB and blood pressure association remained significant after adjusting for age, sex, race, body mass index percentile or waist circumference, sleep efficiency, percentage of rapid eye movement sleep, and snoring. In addition, older age, body mass index percentile, waist circumference, and snoring were significantly associated with blood pressure, independent of SDB. Based on these findings, our study suggests that SDB is significantly associated with higher levels of systolic blood pressure in children aged 5 to 12 years even after adjusting for the various confounding factors. Clinically, the data support the threshold of AHI >or=5 for the initiation of treatment for SDB. Additional research is indicated to assess the efficacy of SDB treatment on reducing blood pressure.

  12. The Effect of Mother's Voice on Arterial Blood Sampling Induced Pain in Neonates Hospitalized in Neonate Intensive Care Unit.

    PubMed

    Azarmnejad, Elham; Sarhangi, Forogh; Javadi, Mahrooz; Rejeh, Nahid

    2015-04-19

    Due to devastating effects of pain in neonates, it is very important to ease it though safe and feasible methods. This study was to determine the effect of familiar auditory stimuli on the arterial blood sampling (ABS) induced pain in term neonates. This study was done on 30 newborns hospitalized in neonate intensive care unit (NICU) of a hospital in Tehran. Research samples were selected by using convenience sampling and randomly divided into two groups of control and test. In the test group, the recorded mothers' voices were played for the newborns before and after blood sampling procedure. Then, pain measures were recorded 10 minutes before, during and 10 minutes after blood collection based on Neonatal Infant Pain Scale (NIPS); then the pain level changes were reviewed and studied. The findings showed significant differences between the control and test groups that indicating the effect of mother's voice on reducing the pain of neonates during the ABS (p<0.005). Research findings demonstrate that mother's voice reduces ABS induced pain in the term neonates.

  13. Trace of heavy metals in maternal and umbilical cord blood samples in association with birth outcomes in Baghdad, Iraq

    NASA Astrophysics Data System (ADS)

    Hasan Rhaif Al-Sahlanee, Mayyadah; Maizan Ramli, Ramzun; Abdul Hassan Ali, Miami; Fadhil Tawfiq, Nada; Zahirah Noor Azman, Nurul; Abdul Rahman, Azhar; Shahrim Mustafa, Iskandar; Noor Ashikin Nik Abdul Razak, Nik; Zakiah Yahaya, Nor; Mohammed Al-Marri, Hana; Syuhada Ayob, Nur; Zakaria, Nabela

    2017-10-01

    Trace elements are essential nutritional components in humans and inconvenient tissue content that have a significant influence on infant size. The aim of this study is to evaluate the effects of concentration of elements (uranium (U), lead (Pb) and iron (Fe)) and absorption of Pb and Fe on maternal and umbilical cord blood samples. The concentration and absorption of Pb and Fe in blood samples were determined by using atomic absorption spectrophotometry device, while the uranium concentration was determined by using CR-39 detector. Fifty women of age 16-44 years are involved in this study. Results show that the maximum and minimum values of both concentration and absorption in the maternal samples were for Pb and Fe, respectively. In addition, for umbilical cord, the maximum values of concentration and absorption were for Fe and the minimum concentration and absorption were for U and Pb, respectively. A significant correlation between maternal and umbilical cord blood samples was found. This indicates that the Pb, U and Fe elements can easily transfer from maternal to the fetal body which impacts the growth of fetus.

  14. "Center punch" and "whole spot" bioanalysis of apixaban in human dried blood spot samples by UHPLC-MS/MS.

    PubMed

    Zheng, Naiyu; Yuan, Long; Ji, Qin C; Mangus, Heidi; Song, Yan; Frost, Charles; Zeng, Jianing; Aubry, Anne-Françoise; Arnold, Mark E

    2015-04-15

    Apixaban (Eliquis™) was developed by Bristol-Myers Squibb (BMS) and Pfizer to use as an antithrombotic/anticoagulant agent and has been recently approved for the prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation. A clinical study of apixaban, sponsored by BMS and Pfizer, included a pilot exploratory portion to evaluate the potential for future drug concentration monitoring using dried blood spot (DBS) sample collection. For DBS sample collection, a fixed blood volume was dispensed onto a DBS card by either regular volumetric pipette (venous blood collection) or capillary dispenser (finger prick blood collection). A 96-well semi-automated liquid-liquid extraction sample preparation procedure was developed to provide clean extracts for UHPLC-MS/MS quantitation. Assays using both partial-spot center punch and whole spot punch were developed and validated. The linear dynamic ranges for all the analyses were from 0.5 to 500 ng/mL. The coefficient of determination (r(2)) values was >0.9944 for all the validation runs. For the center punch approach, the intra-assay precision (%CV) was within 4.4% and inter-assay precision was within 2.6%. The assay accuracy, expressed as %Dev., was within ± 5.4% of the nominal concentrations. One accuracy and precision run was performed using the whole spot approach, the intra-assay precision (%CV) was within 7.1% and the accuracy was within ± 8.0% of the nominal concentrations. In contrast to the center punch approach, the whole spot approach eliminated the effect of hematocrit and high lipids on the analysis of apixaban in human DBS when an accurate sample blood volume was collected on DBS cards. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Persistent organic pollutants in blood samples of Southern Giant Petrels (Macronectes giganteus) from the South Shetland Islands, Antarctica.

    PubMed

    Colabuono, Fernanda I; Vander Pol, Stacy S; Huncik, Kevin M; Taniguchi, Satie; Petry, Maria V; Kucklick, John R; Montone, Rosalinda C

    2016-09-01

    Seabirds play an important role as top consumers in the food web and can be used as biomonitors of exposure to pollutants. Contamination studies involving non-destructive sampling methods are of considerable importance, allowing better evaluation of the levels of pollutants and their toxic effects. In the present study, organohalogen contaminants were analyzed in 113 blood samples from Southern Giant Petrel (Macronectes giganteus) adults and chicks collected in the austral summer of 2011/2012 and 2012/2013 from colonies on Elephant and Livingston Islands, South Shetland, Antarctica. Polychlorinated biphenyls (PCBs), hexachlorobenzene (HCB), pentachlorobenzene (PeCB), mirex, dichlorodiphenyltrichloroetane and derivatives (DDTs) and chlordanes were detected in all birds, whereas polybrominated diphenyl ethers (PBDEs) were not detected in any blood samples. No significant differences were found in organochlorine levels between sampling events. Adults exhibited significantly higher levels than chicks, except for PeCB. PCBs, HCB, mirex and DDTs were statistically similar in males and females from Elephant Island. Females on Livingston Island exhibited higher HCB values than males, but no sex differences were found regarding other organochlorines. The similarity in organochlorine levels between sexes in birds with very marked sexual segregation in feeding habits during the breeding season may indicate that significant amounts of contaminants are acquired during migration to lower latitudes, when the diets of males and females are similar. Birds sampled on Livingston Island exhibited significantly lower levels of PCBs, HCB, DDTs, mirex and chlordanes in comparison to those on Elephant Island, which could be the result of distinct foraging patterns between the two colonies. Organochlorine levels were similar between years in birds captured in two consecutive breeding seasons. Blood samples from Southern Giant Petrels adults and chicks proved to be useful for the comparison

  16. Blood Transcriptomic Comparison of Individuals with and without Autism Spectrum Disorder: A Combined-Samples Mega-Analysis

    PubMed Central

    Tylee, Daniel S.; Hess, Jonathan L.; Quinn, Thomas P.; Barve, Rahul; Huang, Hailiang; Zhang-James, Yanli; Chang, Jeffrey; Stamova, Boryana S.; Sharp, Frank R.; Hertz-Picciotto, Irva; Faraone, Stephen V.; Kong, Sek Won; Glatt, Stephen J.

    2017-01-01

    Blood-based microarray studies comparing individuals affected with autism spectrum disorder (ASD) and typically developing individuals help characterize differences in circulating immune cell functions and offer potential biomarker signal. We sought to combine the subject-level data from previously published studies by mega-analysis to increase the statistical power. We identified studies that compared ex-vivo blood or lymphocytes from ASD-affected individuals and unrelated comparison subjects using Affymetrix or Illumina array platforms. Raw microarray data and clinical meta-data were obtained from seven studies, totaling 626 affected and 447 comparison subjects. Microarray data were processed using uniform methods. Covariate-controlled mixed-effect linear models were used to identify gene transcripts and co-expression network modules that were significantly associated with diagnostic status. Permutation-based gene-set analysis was used to identify functionally related sets of genes that were over- and under-expressed among ASD samples. Our results were consistent with diminished interferon-, EGF-, PDGF-, PI3K-AKT-mTOR-, and RAS-MAPK-signaling cascades, and increased ribosomal translation and NK-cell related activity in ASD. We explored evidence for sex-differences in the ASD-related transcriptomic signature. We also demonstrated that machine-learning classifiers using blood transcriptome data perform with moderate accuracy when data are combined across studies. Comparing our results with those from blood-based studies of protein biomarkers (e.g., cytokines and trophic factors), we propose that ASD may feature decoupling between certain circulating signaling proteins (higher in ASD samples) and the transcriptional cascades which they typically elicit within circulating immune cells (lower in ASD samples). These findings provide insight into ASD-related transcriptional differences in circulating immune cells. PMID:27862943

  17. Appropriate Handling, Processing and Analysis of Blood Samples Is Essential to Avoid Oxidation of Vitamin C to Dehydroascorbic Acid

    PubMed Central

    Pullar, Juliet M.; Carr, Anitra C.

    2018-01-01

    Vitamin C (ascorbate) is the major water-soluble antioxidant in plasma and its oxidation to dehydroascorbic acid (DHA) has been proposed as a marker of oxidative stress in vivo. However, controversy exists in the literature around the amount of DHA detected in blood samples collected from various patient cohorts. In this study, we report on DHA concentrations in a selection of different clinical cohorts (diabetes, pneumonia, cancer, and critically ill). All clinical samples were collected into EDTA anticoagulant tubes and processed at 4 °C prior to storage at −80 °C for subsequent analysis by HPLC with electrochemical detection. We also investigated the effects of different handling and processing conditions on short-term and long-term ascorbate and DHA stability in vitro and in whole blood and plasma samples. These conditions included metal chelation, anticoagulants (EDTA and heparin), and processing temperatures (ice, 4 °C and room temperature). Analysis of our clinical cohorts indicated very low to negligible DHA concentrations. Samples exhibiting haemolysis contained significantly higher concentrations of DHA. Metal chelation inhibited oxidation of vitamin C in vitro, confirming the involvement of contaminating metal ions. Although EDTA is an effective metal chelator, complexes with transition metal ions are still redox active, thus its use as an anticoagulant can facilitate metal ion-dependent oxidation of vitamin C in whole blood and plasma. Handling and processing blood samples on ice (or at 4 °C) delayed oxidation of vitamin C by a number of hours. A review of the literature regarding DHA concentrations in clinical cohorts highlighted the fact that studies using colourimetric or fluorometric assays reported significantly higher concentrations of DHA compared to those using HPLC with electrochemical detection. In conclusion, careful handling and processing of samples, combined with appropriate analysis, is crucial for accurate determination of

  18. Improved age determination of blood and teeth samples using a selected set of DNA methylation markers

    PubMed Central

    Kamalandua, Aubeline

    2015-01-01

    Age estimation from DNA methylation markers has seen an exponential growth of interest, not in the least from forensic scientists. The current published assays, however, can still be improved by lowering the number of markers in the assay and by providing more accurate models to predict chronological age. From the published literature we selected 4 age-associated genes (ASPA, PDE4C, ELOVL2, and EDARADD) and determined CpG methylation levels from 206 blood samples of both deceased and living individuals (age range: 0–91 years). This data was subsequently used to compare prediction accuracy with both linear and non-linear regression models. A quadratic regression model in which the methylation levels of ELOVL2 were squared showed the highest accuracy with a Mean Absolute Deviation (MAD) between chronological age and predicted age of 3.75 years and an adjusted R2 of 0.95. No difference in accuracy was observed for samples obtained either from living and deceased individuals or between the 2 genders. In addition, 29 teeth from different individuals (age range: 19–70 years) were analyzed using the same set of markers resulting in a MAD of 4.86 years and an adjusted R2 of 0.74. Cross validation of the results obtained from blood samples demonstrated the robustness and reproducibility of the assay. In conclusion, the set of 4 CpG DNA methylation markers is capable of producing highly accurate age predictions for blood samples from deceased and living individuals PMID:26280308

  19. Quantification of periodontal pathogens in vascular, blood, and subgingival samples from patients with peripheral arterial disease or abdominal aortic aneurysms.

    PubMed

    Figuero, Elena; Lindahl, Christeel; Marín, María José; Renvert, Stefan; Herrera, David; Ohlsson, Ola; Wetterling, Thomas; Sanz, Mariano

    2014-09-01

    The aim of this investigation is to quantify periodontal pathogens (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Campylobacter rectus, and Tannerella forsythia) in vascular, blood, and subgingival samples. As a secondary objective, two molecular bacterial identification methods (nested polymerase chain reaction [PCR] and quantitative PCR [qPCR]) are compared. Seventy consecutive patients provided a vascular lesion, a blood sample, and 36 subgingival samples. Bacterial DNA was extracted, and qPCR was used to determine the prevalence and amounts of the target pathogens in each sample. Nested PCR was performed only in the samples from vascular lesions. Periodontal examination was performed in 42 patients. Mann-Whitney U or χ(2) tests were used to compare microbiologic results according to periodontal diagnosis. All targeted periodontal pathogens (A. actinomycetemcomitans, P. gingivalis, T. forsythia, or C. rectus) were detected in subgingival samples, with a prevalence rate of 72.2%, 47.2%, 74.3%, and 82.9%, respectively. In 7.1% and 11.4% of vascular and blood samples, bacterial DNA was detected. One patient was positive for A. actinomycetemcomitans in the three types of samples. No differences were found in the levels of targeted bacteria when comparing patients with and without periodontitis. Prevalence rates obtained with nested PCR were significantly higher than those obtained with qPCR. The presence of A. actinomycetemcomitans was demonstrated in vascular, blood, and subgingival samples in one of 36 patients. These results, although with a very low frequency, may support the hypothesis of a translocation of periodontal pathogens from subgingival microbiota to the bloodstream and then to atheromatous plaques in carotid or other peripheral arteries. Nested PCR is not an adequate method for identifying DNA of periodontal pathogens in low quantities because of the high number of false-negative results.

  20. Virological Surveillance of Dengue in Saint Martin and Saint Barthélemy, French West Indies, Using Blood Samples on Filter Paper

    PubMed Central

    Matheus, Séverine; Chappert, Jean-Loup; Cassadou, Sylvie; Berger, Franck; Labeau, Bhetty; Bremand, Laetitia; Winicki, Alain; Huc-Anais, Patricia; Quenel, Philippe; Dussart, Philippe

    2012-01-01

    To strengthen active dengue surveillance in Saint Martin and Saint Barthélemy, two French Caribbean islands, we evaluated the epidemiological usefulness of collecting blood samples from NS1-positive dengue patients on filter paper to identify the dengue serotypes circulating in these regions during a 27-month period. This approach allowed dengue serotypes to be identified by reverse transcriptase-polymerase chain reaction in 90.1% of the total set of 666 samples analyzed and, in 95.5% of the samples collected during the acute phase of the disease. This prospective virological surveillance using blood samples absorbed onto filter paper, which were stored at 4°C and shipped at ambient temperature to a specialized laboratory for analysis, allowed us to avoid the logistic and financial costs associated with shipping frozen venous blood samples. This surveillance system offers a low-cost alternative for reinforcing dengue prevention in areas where specialized laboratories do not exist, notably by facilitating the early detection of potentially new dengue serotypes. PMID:22232467

  1. Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin Variants

    NASA Astrophysics Data System (ADS)

    Edwards, Rebecca L.; Griffiths, Paul; Bunch, Josephine; Cooper, Helen J.

    2012-11-01

    We have previously shown that liquid microjunction surface sampling of dried blood spots coupled with high resolution top-down mass spectrometry may be used for screening of common hemoglobin variants HbS, HbC, and HbD. In order to test the robustness of the approach, we have applied the approach to unknown hemoglobin variants. Six neonatal dried blood spot samples that had been identified as variants, but which could not be diagnosed by current screening methods, were analyzed by direct surface sampling top-down mass spectrometry. Both collision-induced dissociation and electron transfer dissociation mass spectrometry were employed. Four of the samples were identified as β-chain variants: two were heterozygous Hb D-Iran, one was heterozygous Hb Headington, and one was heterozygous Hb J-Baltimore. The fifth sample was identified as the α-chain variant heterozygous Hb Phnom Penh. Analysis of the sixth sample suggested that it did not in fact contain a variant. Adoption of the approach in the clinic would require speed in both data collection and interpretation. To address that issue, we have compared manual data analysis with freely available data analysis software (ProsightPTM). The results demonstrate the power of top-down proteomics for hemoglobin variant analysis in newborn samples.

  2. Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    PubMed Central

    Kessler, Harald H.; Stelzl, Evelyn; Raggam, Reinhard B.; Haas, Josef; Kirchmeir, Franz; Hegenbarth, Karin; Daghofer, Elisabeth; Santner, Brigitte I.; Marth, Egon; Stauber, Rudolf E.

    2001-01-01

    In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at “date zero.” In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport. PMID:11325991

  3. Determining population and developmental pharmacokinetics of metronidazole using plasma and dried blood spot samples from premature infants.

    PubMed

    Cohen-Wolkowiez, Michael; Sampson, Mario; Bloom, Barry T; Arrieta, Antonio; Wynn, James L; Martz, Karen; Harper, Barrie; Kearns, Gregory L; Capparelli, Edmund V; Siegel, David; Benjamin, Daniel K; Smith, P Brian

    2013-09-01

    Limited pharmacokinetic (PK) data of metronidazole in premature infants have led to various dosing recommendations. Surrogate efficacy targets for metronidazole are ill-defined and therefore aimed to exceed minimum inhibitory concentration of organisms responsible for intra-abdominal infections. We evaluated the PK of metronidazole using plasma and dried blood spot samples from infants ≤32 weeks gestational age in an open-label, PK, multicenter (N = 3) study using population PK modeling (NONMEM). Monte Carlo simulations (N = 1000 virtual subjects) were used to evaluate the surrogate efficacy target. Metabolic ratios of parent and metabolite were calculated. Twenty-four premature infants (111 plasma and 51 dried blood spot samples) were enrolled: median (range) gestational age at birth 25 (23-31) weeks, postnatal age 27 (1-82) days, postmenstrual age 31 (24-39) weeks and weight 740 (431-1466) g. Population clearance (L/h/kg) was 0.038 × (postmenstrual age/30) and volume of distribution (L/kg) of 0.93. PK parameter estimates and precision were similar between plasma and dried blood spot samples. Metabolic ratios correlated with clearance. Simulations suggested the majority of infants in the neonatal intensive care unit (>80%) would meet the surrogate efficacy target using postmenstrual age-based dosing.

  4. Blood transcriptomic comparison of individuals with and without autism spectrum disorder: A combined-samples mega-analysis.

    PubMed

    Tylee, Daniel S; Hess, Jonathan L; Quinn, Thomas P; Barve, Rahul; Huang, Hailiang; Zhang-James, Yanli; Chang, Jeffrey; Stamova, Boryana S; Sharp, Frank R; Hertz-Picciotto, Irva; Faraone, Stephen V; Kong, Sek Won; Glatt, Stephen J

    2017-04-01

    Blood-based microarray studies comparing individuals affected with autism spectrum disorder (ASD) and typically developing individuals help characterize differences in circulating immune cell functions and offer potential biomarker signal. We sought to combine the subject-level data from previously published studies by mega-analysis to increase the statistical power. We identified studies that compared ex vivo blood or lymphocytes from ASD-affected individuals and unrelated comparison subjects using Affymetrix or Illumina array platforms. Raw microarray data and clinical meta-data were obtained from seven studies, totaling 626 affected and 447 comparison subjects. Microarray data were processed using uniform methods. Covariate-controlled mixed-effect linear models were used to identify gene transcripts and co-expression network modules that were significantly associated with diagnostic status. Permutation-based gene-set analysis was used to identify functionally related sets of genes that were over- and under-expressed among ASD samples. Our results were consistent with diminished interferon-, EGF-, PDGF-, PI3K-AKT-mTOR-, and RAS-MAPK-signaling cascades, and increased ribosomal translation and NK-cell related activity in ASD. We explored evidence for sex-differences in the ASD-related transcriptomic signature. We also demonstrated that machine-learning classifiers using blood transcriptome data perform with moderate accuracy when data are combined across studies. Comparing our results with those from blood-based studies of protein biomarkers (e.g., cytokines and trophic factors), we propose that ASD may feature decoupling between certain circulating signaling proteins (higher in ASD samples) and the transcriptional cascades which they typically elicit within circulating immune cells (lower in ASD samples). These findings provide insight into ASD-related transcriptional differences in circulating immune cells. © 2016 Wiley Periodicals, Inc. © 2016 Wiley

  5. A new comprehensive technique of catheterisation, blood sampling, sample preparation and sample analysis by means of high-pressure liquid chromatography for pharmacokinetic studies with estradiol-linked nitrosoureas and their metabolites.

    PubMed

    Betsch, B; Berger, M R; Spiegelhalder, B

    1990-09-01

    Estradiol-linked nitrosoureas are offering new perspectives in the antineoplastic chemotherapy of estradiol-receptor positive mammary carcinomas. In such a molecule estradiol has the function of a carrier which brings about a specific accumulation of the anticancer drug in estradiol-receptor containing tumor cells. However, there is only little knowledge about the pharmacokinetic behavior of this new group of anticancer agents. For that reason a new comprehensive technique of catheterisation, blood sampling, sample preparation and sample analysis with high-pressure liquid chromatography (HPLC) for preclinical pharmacokinetic studies with estradiol-linked nitrosoureas and their metabolites has been developed. N-(2-Chloroethyl)-N-nitroso-carbamoyl-L-alanine-estradiol-17-ester (CNC-alanine-estradiol-17-ester) and N-(2-chloroethyl)-N-nitroso-carbamoyl-L-alanine (CNC-alanine) were used as test compounds. The drugs were tested in female Sprague-Dawley rats with chemically induced mammary carcinomas. The laboratory animals were supplied with two catheters prior to the pharmacokinetic experiments. The blood samples were drawn from the vena cava catheter after the drug had been applied through a vena jugularis catheter. The compounds were extracted from plasma with C18 silicagel reversed phase cartridges. The clean-up technique delivered clear samples only slightly contaminated with the biological matrix. The recovery from plasma was 75 +/- 5% for the hormone-linked CNC-alanine-estradiol-17-ester and 70 +/- 5% for the unlinked CNC-alanine. The analysis was carried out by means of HPLC.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Rapid Isolation of Viable Circulating Tumor Cells from Patient Blood Samples

    PubMed Central

    Hughes, Andrew D.; Mattison, Jeff; Powderly, John D.; Greene, Bryan T.; King, Michael R.

    2012-01-01

    following isolation, and these samples typically consist of >50% viable primary cancer cells from each patient. This device has been used to capture viable CTC from both diluted whole blood and buffy coat samples. Ultimately, we present a technique with functionality in a clinical setting to develop personalized cancer therapies. PMID:22733259

  7. Attitudes and awareness of female genital mutilation: a questionnaire-based study in a Kenyan hospital.

    PubMed

    Livermore, L; Monteiro, R; Rymer, J

    2007-11-01

    There are considerable efforts in Kenya to increase awareness of the issues and health risks associated with female genital mutilation (FGM) through educational programmes. The Kenyan government formally outlawed FGM in 2001. This questionnaire-based study aimed to explore attitudes and awareness of FGM in Kenya with particular reference to the law, health complications and educational programmes. A significant decline in the prevalence of FGM was demonstrated and awareness of health complications of FGM shown to be the main factor causing this trend. The need for further efforts to eradicate the practice and the importance of religion and culture in shaping social attitudes was evident. The outlawing of FGM was considered a positive advance but may have the detrimental effect of deterring women from seeking medical assistance for complications relating to FGM.

  8. Pre-analytical effects of blood sampling and handling in quantitative immunoassays for rheumatoid arthritis.

    PubMed

    Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K

    2012-04-30

    Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker

  9. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    PubMed

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  10. Level of confidence in venepuncture and knowledge in determining causes of blood sample haemolysis among clinical staff and phlebotomists.

    PubMed

    Makhumula-Nkhoma, Nellie; Whittaker, Vicki; McSherry, Robert

    2015-02-01

    To investigate the association between confidence level in venepuncture and knowledge in determining causes of blood sample haemolysis among clinical staff and phlebotomists. Various collection methods are used to perform venepuncture, also called phlebotomy, the act of drawing blood from a patient using a needle. The collection method used has an impact on preanalytical blood sample haemolysis. Haemolysis is the breakdown of red blood cells, which makes the sample unsuitable. Despite available evidence on the common causes, extensive literature search showed a lack of published evidence on the association of haemolysis with staff confidence and knowledge. A quantitative primary research design using survey method. A purposive sample of 290 clinical staff and phlebotomists conducting venepuncture in one North England hospital participated in this quantitative survey. A three-section web-based questionnaire comprising demographic profile, confidence and competence levels, and knowledge sections was used to collect data in 2012. The chi-squared test for independence was used to compare the distribution of responses for categorical data. anova was used to determine mean difference in the knowledge scores of staff with different confidence levels. Almost 25% clinical staff and phlebotomists participated in the survey. There was an increase in confidence at the last venepuncture among staff of all categories. While doctors' scores were higher compared with healthcare assistants', p ≤ 0·001, nurses' were of wide range and lowest. There was no statistically significant difference (at the 5% level) in the total knowledge scores and confidence level at the last venepuncture F(2,4·690) = 1·67, p = 0·31 among staff of all categories. Evidence-based measures are required to boost staff knowledge base of preanalytical blood sample haemolysis for standardised and quality service. Monitoring and evaluation of the training, conducting and monitoring haemolysis rate are

  11. Household water insecurity is associated with a range of negative consequences among pregnant Kenyan women of mixed HIV status.

    PubMed

    Krumdieck, Natalie R; Collins, Shalean M; Wekesa, Pauline; Mbullo, Patrick; Boateng, Godfred O; Onono, Maricianah; Young, Sera L

    2016-12-01

    Water insecurity (WI) is a serious and worsening problem worldwide, but its role in health outcomes among people living with HIV or pregnant women is unknown. We assessed experiences of WI in a cohort of 323 pregnant Kenyan women of mixed HIV status. The majority (77.7%) had at least one experience of WI in the previous month; it was associated with negative economic, nutrition, disease, and psychosocial outcomes. A standardized cross-culturally valid household WI scale would facilitate assessment of the prevalence and consequences of WI, and increased attention to WI could reveal an overlooked, but modifiable, cause of adverse HIV outcomes.

  12. Automated processing of whole blood samples into microliter aliquots of plasma.

    PubMed

    Burtis, C A; Johnson, W W; Walker, W A

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.

  13. Noncontact discrimination of animal and human blood with vacuum blood vessel and factors affect the discrimination

    NASA Astrophysics Data System (ADS)

    Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Li, Hongxiao; Li, Yingxin; Fu, Zhigang; Guan, Yang; Li, Gang; Lin, Ling

    2017-03-01

    Discrimination of human and nonhuman blood is crucial for import-export ports and inspection and quarantine departments. Current methods are usually destructive, complicated and time-consuming. We had previously demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize human blood discrimination. In that research, the spectra were measured with the fiber probe under the surface of blood samples. However, open sampling may pollute the blood samples. Virulence factors in blood samples can also endanger inspectors. In this paper, we explored the classification effect with the blood samples measured in the original containers-vacuum blood vessel. Furthermore, we studied the impact of different conditions of blood samples, such as coagulation and hemolysis, on the prediction ability of the discrimination model. The calibration model built with blood samples in different conditions displayed a satisfactory prediction result. This research demonstrated that visible and near-infrared diffuse reflectance spectroscopy method was potential for noncontact discrimination of human blood.

  14. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of thesemore » selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.« less

  15. Deficits in knowledge, attitude, and practice towards blood culture sampling: results of a nationwide mixed-methods study among inpatient care physicians in Germany.

    PubMed

    Raupach-Rosin, Heike; Duddeck, Arne; Gehrlich, Maike; Helmke, Charlotte; Huebner, Johannes; Pletz, Mathias W; Mikolajczyk, Rafael; Karch, André

    2017-08-01

    Blood culture (BC) sampling rates in Germany are considerably lower than recommended. Aim of our study was to assess knowledge, attitudes, and practice of physicians in Germany regarding BC diagnostics. We conducted a cross-sectional mixed-methods study among physicians working in inpatient care in Germany. Based on the results of qualitative focus groups, a questionnaire-based quantitative study was conducted in 2015-2016. In total, 706 medical doctors and final-year medical students from 11 out of 16 federal states in Germany participated. BC sampling was considered an important diagnostic tool by 95% of the participants. However, only 23% of them would collect BCs in three scenarios for which BC ordering is recommended by present guidelines in Germany; almost one out of ten physicians would not have taken blood cultures in any of the three scenarios. The majority of participants (74%) reported not to adhere to the guideline recommendation that blood culture sampling should include at least two blood culture sets from two different injection sites. High routine in blood culture sampling, perceived importance of blood culture diagnostics, the availability of an in-house microbiological lab, and the department the physician worked in were identified as predictors for good blood culture practice. Our study suggests that there are substantial deficits in BC ordering and the application of guidelines for good BC practice in Germany. Based on these findings, multimodal interventions appear necessary for improving BC diagnostics.

  16. A strategy to increase adoption of locally-produced, ceramic cookstoves in rural Kenyan households.

    PubMed

    Silk, Benjamin J; Sadumah, Ibrahim; Patel, Minal K; Were, Vincent; Person, Bobbie; Harris, Julie; Otieno, Ronald; Nygren, Benjamin; Loo, Jennifer; Eleveld, Alie; Quick, Robert E; Cohen, Adam L

    2012-05-16

    Exposure to household air pollutants released during cooking has been linked to numerous adverse health outcomes among residents of rural areas in low-income countries. Improved cookstoves are one of few available interventions, but achieving equity in cookstove access has been challenging. Therefore, innovative approaches are needed. To evaluate a project designed to motivate adoption of locally-produced, ceramic cookstoves (upesi jiko) in an impoverished, rural African population, we assessed the perceived benefits of the cookstoves (in monetary and time-savings terms), the rate of cookstove adoption, and the equity of adoption. The project was conducted in 60 rural Kenyan villages in 2008 and 2009. Baseline (n = 1250) and follow-up (n = 293) surveys and a stove-tracking database were analyzed. At baseline, nearly all respondents used wood (95%) and firepits (99%) for cooking; 98% desired smoke reductions. Households with upesi jiko subsequently spent <100 Kenyan Shillings/week on firewood more often (40%) than households without upesi jiko (20%) (p = 0.0002). There were no significant differences in the presence of children <2 years of age in households using upesi jiko (48%) or three-stone stoves (49%) (p = 0.88); children 2-5 years of age were less common in households using upesi jiko versus three-stone stoves (46% and 69%, respectively) (p = 0.0001). Vendors installed 1,124 upesi jiko in 757 multi-family households in 18 months; 68% of these transactions involved incentives for vendors and purchasers. Relatively few (<10%) upesi jiko were installed in households of women in the youngest age quartile (<22 years) or among households in the poorest quintile. Our strategy of training of local vendors, appropriate incentives, and product integration effectively accelerated cookstove adoption into a large number of households. The strategy also created opportunities to reinforce health messages and promote cookstoves sales and installation. However, the project

  17. Developing high throughput quantitative PCR assays for diagnosing Ikeda and other Theileria orientalis types common to New Zealand in bovine blood samples.

    PubMed

    Pulford, D J; Gias, E; Bueno, I M; McFadden, Amj

    2016-01-01

    To develop rapid, quantitative PCR (qPCR) assays using high resolution melt (HRM) analysis and type-specific TaqMan assays for identifying the prevalent types of Theileria orientalis found in New Zealand cattle; and to evaluate their analytical and diagnostic characteristics compared with other assays for T. orientalis. Nucleotide sequences aligned with T. orientalis Buffeli, Chitose and Ikeda types, obtained from DNA extracted from blood samples from infected cattle, were used to design HRM and type-specific probe-based qPCR assays. The three type-specific assays were also incorporated into a single-tube multiplex qPCR assay. These assays were validated using DNA extracted from blood samples from cattle in herds with or without clinical signs of T. orientalis infection, other veterinary laboratory samples, as well as plasmids containing T. orientalis type-specific sequences. Diagnostic specificity (DSp) and sensitivity (DSe) estimates for the qPCR assays were compared to blood smear piroplasm results, and other PCR assays for T. orientalis. Copy number estimates of Ikeda DNA in blood were determined from cattle exhibiting anaemia using the Ikeda-specific qPCR assay. The T. orientalis type-specific and the HRM qPCR assays displayed 100% analytical specificity. The Ikeda-specific qPCR assay exhibited linearity (R(2) = 0.997) with an efficiency of 94.3%. Intra-assay CV were ≤0.08 and inter-assay CV were ≤0.095. For blood samples from cows with signs of infection with T. orientalis, the DSp and DSe of the multiplex probe qPCR assay were 93 and 96%, respectively compared with blood smears, and 97 and 100%, respectively compared with conventional PCR assays. For the Ikeda-specific qPCR assay, the number of positive samples (n=66) was slightly higher than a conventional PCR assay (n=64). The concentration of Ikeda genomes in blood samples from 41 dairy cows with signs of infection with T. orientalis ranged between 5.6 × 10(4) and 3.3 × 10(6) genomes per

  18. Duffy Blood Group Genotyping in Thai Blood Donors

    PubMed Central

    Intharanut, Kamphon; Siriphanthong, Kanokpol; Nathalang, Siriporn; Kupatawintu, Pawinee

    2015-01-01

    Background Duffy (FY) blood group genotyping is important in transfusion medicine because Duffy alloantibodies are associated with delayed hemolytic transfusion reactions and hemolytic disease of the fetus and newborn. In this study, FY allele frequencies in Thai blood donors were determined by in-house PCR with sequence-specific primers (PCR-SSP), and the probability of obtaining compatible blood for alloimmunized patients was assessed. Methods Five hundred blood samples from Thai blood donors of the National Blood Centre, Thai Red Cross Society, were included. Only 200 samples were tested with anti-Fya and anti-Fyb using the gel technique. All 500 samples and four samples from a Guinea family with the Fy(a-b-) phenotype were genotyped by using PCR-SSP. Additionally, the probability of obtaining antigen-negative red blood cells (RBCs) for alloimmunized patients was calculated according to the estimated FY allele frequencies. Results The FY phenotyping and genotyping results were in 100% concordance. The allele frequencies of FY*A and FY*B in 500 central Thais were 0.962 (962/1,000) and 0.038 (38/1,000), respectively. Although the Fy(a-b-) phenotype was not observed in this study, FY*BES/FY*BES was identified by PCR-SSP in the Guinea family and was confirmed by DNA sequencing. Conclusions Our results confirm the high frequency of the FY*A allele in the Thai population, similar to that of Asian populations. At least 500 Thai blood donors are needed to obtain two units of antigen-negative RBCs for the Fy(a-b+) phenotype. PMID:26354350

  19. Stable isotope analyses of tooth enamel carbonate of large herbivores from the Tugen Hills deposits: Palaeoenvironmental context of the earliest Kenyan hominids

    NASA Astrophysics Data System (ADS)

    Roche, Damien; Ségalen, Loïc; Senut, Brigitte; Pickford, Martin

    2013-11-01

    Understanding shifts in past climatic and environmental conditions are crucial for throwing light on human evolution. Available reconstructions of the palaeoecology of faunal and floral assemblages indicate that the earliest Kenyan hominids, including Orrorin tugenensis, are associated with forest landscapes. In this study, we present stable isotope data of tooth enamel carbonate of large herbivores associated with these hominids in order further to evaluate their environmental context. Fossil teeth were sampled in the Lukeino Formation (6.1-5.7 Ma, Late Miocene) and the Mabaget Formation (5.3-4.5 Ma, Early Pliocene) at the foot of the Tugen Hills (Great Rift Valley). Despite chemical changes in fossil enamel, preservation of the palaeoenvironmental signals is supported by the difference in δ18O between hippos and terrestrial fauna. Moreover, the giraffid specimen from the Mabaget Formation exhibits one of the highest δ18O values, as expected for a drought-tolerant animal. The δ13C of large herbivores indicates that the earliest Kenyan hominids inhabited a mixed C3-C4 environment as did Ardipithecus (Ethiopia) and Sahelanthropus (Chad), two early putative hominids. The Tugen Hills might have been a wooded grassland with patches of woodland. There is no record of closed-canopy forest at the time of deposition. We emphasize differences in food habits among herbivore groups. Deinotheres, nearly all elephantids and the giraffid individual had a C3 diet which reflected browsing behaviour. The intake of C4 plants prevailed for equids and gomphotheres and was consistent with grazing habits. Most hippos and suids were mixed C3-C4 feeders and consequently were generalist herbivores. Bovids and rhinos had a diet ranging from C3 to C4 plants. Variations in δ13C and δ18O among faunal assemblages suggest changes in local climate and vegetation. Moister conditions likely occurred in the Early Pliocene and the latest Miocene (ca. 5.7 Ma) than before. The C3 plant biomass

  20. A method for direct assessment of tissue-nonspecific alkaline phosphatase (TNAP) inhibitors in blood samples.

    PubMed

    Sergienko, Eduard A; Sun, Qing; Ma, Chen-Ting

    2013-01-01

    Tissue nonspecific alkaline phosphatase (TNAP) is one of four human alkaline phosphatases (AP), a family of exocytic enzymes that catalyze hydrolysis of phospho-monoesters in bone, liver, kidney, and various other tissues. Overexpression of TNAP gives rise to excessive bone and soft tissue mineralization, including blood vessel calcification. Our prior screening campaigns have found several leads against this attractive therapeutic target using in vitro assay with a recombinant enzyme; these compounds were further optimized using medicinal chemistry approaches. To prioritize compounds for their use in animal models, we have designed and developed a biomarker assay for in situ detection of TNAP activity within human and mouse blood samples at physiological pH. This assay is suitable for screening compounds in 1,536-well plates using blood plasma from different mammalian species. The user may choose from two different substrates based on the need for greater assay simplicity or sensitivity.

  1. Relative social standing and suicide ideation among Kenyan males: the interpersonal theory of suicide in context.

    PubMed

    Goodman, M L; Serag, H; Keiser, P K; Gitari, S; Raimer, B G

    2017-10-01

    The purpose of this study is to investigate the association between subjective social status and suicide ideation in a sample of young Kenyan men (age 18-34 years). Situating insights from the interpersonal theory of suicide within social determinants of health framework, we consider whether lower subjective social status predicts lower collective self-esteem (CSE), hopelessness, less meaning in life and more loneliness, and whether these characteristics mediate associations between subjective social status and suicide ideation. A community-based, semi-rural sample (n = 532) of young men, aged 18-34 years, was collected using a standardized questionnaire. The survey questionnaire included the following validated scale items: the short form of the Social and Emotional Loneliness Scale for Adults, CSE, Herth Hope Index, the Meaning in Life Questionnaire, and the Modified Scale for Suicide Ideation. Regression and mediation analyses were used to test hypotheses. Nearly 12% of respondents reported suicide ideation. Suicide ideation was significantly more common among survey respondents who reported lower subjective social standing. In the first of two mediation models, we found that lower CSE and more loneliness mediate the association between lower subjective social status and suicide ideation. In the second model, we found that respondents with lower CSE and more loneliness expressed lower hope and meaning in life, which also mediated pathways to suicide ideation. Findings show a novel synthesis of social determinants literature with the interpersonal theory of suicide. Suicide ideation, along with other mental and social outcomes, may figure more prominently than previously appreciated in the benefits of socio-economic equality. Those who do not participate equally in socio-economic development may be at greater risk of engaging in suicide ideation and behaviors. Suicide prevention research and programmatic responses should adopt a health equity perspective to

  2. Childhood exposure to emotional abuse and later life stress among Kenyan women: a mediation analysis of cross-sectional data.

    PubMed

    Goodman, Michael L; Gutarra, Claudia; Billingsley, Katherine M; Keiser, Philip H; Gitari, Stanley

    2017-07-01

    We explore whether perceived stress among Kenyan mothers is predicted by childhood exposure to emotional abuse - both witnessed among parents and experienced directly. Further, we explore whether this association is mediated by social support, family functioning and polygynous marriage. We used cross-sectional data from a systematic random sample (n = 1974) of mothers in semi-rural Kenya. Data were collected using validated scales and trained interviewers. Analyses were conducted using bootstrapped structural equation models and fixed-effects linear regression models, controlling for age and household wealth. Reported experience of emotional abuse - both directly experienced and observed among household adults - was high in the present population (72.5% and 69%, respectively). Perceived stress among women was significantly higher if they were exposed to more emotional abuse during childhood (p < .001). Lower social support, worse family functioning and higher rates of polygynous marriage mediated pathways between emotional abuse exposure during childhood and adult perceived stress. Future research should investigate whether social integration, identity formation and self-esteem underlie observed dynamics in sub-Saharan Africa. Efforts to promote social integration and support should target children currently experiencing emotional abuse, and may include child-targeted high quality television programing and adult-targeted media and celebrity campaigns.

  3. Comparison of hematologic values in blood samples with lithium heparin or dipotassium ethylenediaminetetraacetic acid anticoagulants in Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Guzman, David Sanchez-Migallon; Mitchell, Mark A; Gaunt, Stephen D; Beaufrère, Hugues; Tully, Thomas N

    2008-06-01

    Blood samples were collected from 20 Hispaniolan Amazon parrots (Amazona ventralis) and were divided into tubes that contained dipotassium ethylenediaminetetraacetic acid (K2EDTA) and lithium heparin. Complete blood cell counts were determined in each sample within 2 hours of collection. The level of agreement in results was moderate for plasma protein, packed cell volume (PCV), and leukocyte, monocyte, and lymphocyte counts between the anticoagulants. Plasma protein and PCV values were significantly lower in samples with lithium heparin than in those with K2EDTA, whereas lymphocyte numbers were significantly higher in lithium heparin samples than in K2EDTA samples. The level of agreement was good for the other cell types (heterophils, eosinophils, and basophils) when comparing the different anticoagulants. The poor level of agreement between anticoagulants with the increase in thrombocyte clumping in lithium heparin samples indicates that the use of lithium heparin as anticoagulant may affect thrombocyte count. No negative effects on morphology and staining of blood cells were apparent in smears from heparin samples compared with K2EDTA samples. Within the different values compared, the limits of agreement are small enough to be confident that lithium heparin can be used for routine CBC counts in a clinical setting. The use of the same anticoagulant should be recommended to follow trends within the same patient, especially when considering plasma protein concentration, PCV, and lymphocyte count.

  4. Phthalocyanine-BODIPY dye: synthesis, characterization, and utilization for pattern recognition of CYFRA 21-1 in whole blood samples.

    PubMed

    Stefan-van Staden, Raluca-Ioana; Comnea-Stancu, Ionela Raluca; Yanık, Hülya; Göksel, Meltem; Alexandru, Anghel; Durmuş, Mahmut

    2017-10-01

    Phthalocyanine-BODIPY dye (BODIPY = boron dipyrromethene) was synthesized, fully characterized, and used for molecular recognition of CYFRA 21-1, a lung cancer biomarker, from whole blood samples. Thin films of three magnesium oxides ((MgO) n , where n = 8, 9, or 10)) were deposited on a paper substrate, and they were immersed in a solution of phthalocyanine-BODIPY dye (1.17 × 10 -3  mol/L) for the design of stochastic sensors. Limits of determination of picograms per milliliter magnitude order were recorded for the proposed stochastic sensors. CYFRA 21-1 was reliably identified and determined with recoveries higher than 95% and RSD lower than 1% in whole blood samples.

  5. Validation of a point-of-care (POC) lactate testing device for fetal scalp blood sampling during labor: clinical considerations, practicalities and realities.

    PubMed

    Reif, Philipp; Lakovschek, Ioanna; Tappauf, Carmen; Haas, Josef; Lang, Uwe; Schöll, Wolfgang

    2014-06-01

    Although fetal blood sampling for pH is well established the use of lactate has not been widely adopted. This study validated the performance and utility of a handheld point-of-care (POC) lactate device in comparison with the lactate and pH values obtained by the ABL 800 blood gas analyzer. The clinical performance and influences on accuracy and decision-making criteria were assessed with freshly taken fetal blood scalp samples (n=57) and umbilical cord samples (n=310). Bland-Altman plot was used for data plotting and analyzing the agreement between the two measurement devices and correlation coefficients (R²) were determined using Passing-Bablok regression analysis. Sample processing errors were much lower in the testing device (22.8% vs. 0.5%). Following a preclinical assessment and calibration offset alignment (0.5 mmol/L) the test POC device showed good correlation with the reference method for lactate FBS (R²=0.977, p<0.0001, 95% CI 0.9 59-0.988), arterial cord blood (R²=0.976, p<0.0001, 95% CI 0.967-0.983) and venous cord blood (R²=0.977, p<0.0001, 95% CI 0.968-0.984). A POC device which allows for a calibration adjustment to be made following preclinical testing can provide results that will correlate closely to an incumbent lactate method such as a blood gas analyzer. The use of a POC lactate device can address the impracticality and reality of pH sample collection and testing failures experienced in day to day clinical practice. For the StatStrip Lactate meter we suggest using a lactate cut-off of 5.1 mmol/L for predicting fetal acidosis (pH<7.20).

  6. The impact of lymphocyte isolation on induced DNA damage in human blood samples measured by the comet assay.

    PubMed

    Bausinger, Julia; Speit, Günter

    2016-09-01

    The comet assay is frequently used in human biomonitoring for the detection of exposure to genotoxic agents. Peripheral blood samples are most frequently used and tested either as whole blood or after isolation of lymphocytes (i.e. peripheral blood mononuclear cells, PBMC). To investigate a potential impact of lymphocyte isolation on induced DNA damage in human blood samples, we exposed blood ex vivo to mutagens with different modes of genotoxic action. The comet assay was performed either directly with whole blood at the end of the exposure period or with lymphocytes isolated directly after exposure. In addition to the recommended standard protocol for lymphocyte isolation, a shortened protocol was established to optimise the isolation procedure. The results indicate that the effects of induced DNA strand breaks and alkali-labile sites induced by ionising radiation and alkylants, respectively, are significantly reduced in isolated lymphocytes. In contrast, oxidative DNA base damage (induced by potassium bromate) and stable bulky adducts (induced by benzo[a]pyrene-7,8-dihydrodiol-9,10-epoxide; BPDE) seem to be less affected. Our findings suggest that in vivo-induced DNA damage might also be reduced in isolated lymphocytes in comparison with the whole blood depending of the types of DNA damage induced. Because only small genotoxic effects can generally be expected in human biomonitoring studies with the comet assay after occupational and environmental exposure to genotoxic agents, any loss might be relevant and should be avoided. The possibility of such effects and their potential impact on variability of comet assay results in human biomonitoring should be considered when performing or evaluating such kind of studies. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Molecular identification and phylogenetic analysis of Wuchereria bancrofti from human blood samples in Egypt.

    PubMed

    Abdel-Shafi, Iman R; Shoieb, Eman Y; Attia, Samar S; Rubio, José M; Ta-Tang, Thuy-Huong; El-Badry, Ayman A

    2017-03-01

    Lymphatic filariasis (LF) is a serious vector-borne health problem, and Wuchereria bancrofti (W.b) is the major cause of LF worldwide and is focally endemic in Egypt. Identification of filarial infection using traditional morphologic and immunological criteria can be difficult and lead to misdiagnosis. The aim of the present study was molecular detection of W.b in residents in endemic areas in Egypt, sequence variance analysis, and phylogenetic analysis of W.b DNA. Collected blood samples from residents in filariasis endemic areas in five governorates were subjected to semi-nested PCR targeting repeated DNA sequence, for detection of W.b DNA. PCR products were sequenced; subsequently, a phylogenetic analysis of the obtained sequences was performed. Out of 300 blood samples, W.b DNA was identified in 48 (16%). Sequencing analysis confirmed PCR results identifying only W.b species. Sequence alignment and phylogenetic analysis indicated genetically distinct clusters of W.b among the study population. Study results demonstrated that the semi-nested PCR proved to be an effective diagnostic tool for accurate and rapid detection of W.b infections in nano-epidemics and is applicable for samples collected in the daytime as well as the night time. PCR products sequencing and phylogenitic analysis revealed three different nucleotide sequences variants. Further genetic studies of W.b in Egypt and other endemic areas are needed to distinguish related strains and the various ecological as well as drug effects exerted on them to support W.b elimination.

  8. Does topical amethocaine gel reduce pain from heel prick blood sampling in premature infants? A randomized double-blind cross-over controlled study

    PubMed Central

    Patel, Amita; Czerniawski, Barbara; Gray, Shari; Lui, Eric

    2003-01-01

    BACKGROUND: Heel prick blood sampling is the most common painful invasive procedure performed on neonates. Currently, there are no effective ways to provide pain relief from this painful procedure. OBJECTIVE: To assess the efficacy of the topical anesthetic amethocaine 4% gel (Ametop, Smith & Nephew Inc, St Laurent) in reducing the pain of heel prick blood sampling in neonates. METHODS: A randomized, double-blind, placebo controlled, crossover trial was conducted. Neonates between 33 to 37 weeks’ gestational age in their first seven days of life were eligible. Heel prick blood sampling was performed on each participant twice. Each infant was randomly assigned to receive either amethocaine 4% gel or placebo to the heel for the first prick, and then received the alternative agent for the second prick. Prick pain was assessed using both Premature Infant Pain Profile (PIPP) and Neonatal Infant Pain Scale (NIPS). Squeeze pain was assessed by NIPS. RESULTS: Ten babies were recruited. There were no significant differences in the average PIPP and NIPS scores between the treatment and placebo groups for both prick and squeeze pains from heel prick blood sampling. For prick pain, linear-regression showed significant correlation between the PIPP and NIPS scores. No adverse reactions were observed after application of either the active or placebo agents. CONCLUSION: Topical amethocaine 4% gel is not shown to reduce prick and squeeze pains significantly from heel prick blood sampling in neonates between 33 to 37 weeks’ gestational age. Further studies are needed to find ways to provide effective pain relief from this common procedure. PMID:20020001

  9. The economic costs of malaria in four Kenyan districts: do household costs differ by disease endemicity?

    PubMed

    Chuma, Jane; Okungu, Vincent; Molyneux, Catherine

    2010-06-02

    Malaria inflicts significant costs on households and on the economy of malaria endemic countries. There is also evidence that the economic burden is higher among the poorest in a population, and that cost burdens differ significantly between wet and dry seasons. What is not clear is whether, and how, the economic burden of malaria differs by disease endemicity. The need to account for geographical and epidemiological differences in the estimation of the social and economic burden of malaria is well recognized, but there is limited data, if any, to support this argument. This study sought to contribute towards filling this gap by comparing malaria cost burdens in four Kenyan districts of different endemicity. A cross-sectional household survey was conducted during the peak malaria transmission season in the poorest areas in four Kenyan districts with differing malaria transmission patterns (n = 179 households in Bondo; 205 Gucha; 184 Kwale; 141 Makueni). There were significant differences in duration of fever, perception of fever severity and cost burdens. Fever episodes among adults and children over five years in Gucha and Makueni districts (highland endemic and low acute transmission districts respectively) lasted significantly longer than episodes reported in Bondo and Kwale districts (high perennial transmission and seasonal, intense transmission, respectively). Perceptions of illness severity also differed between districts: fevers reported among older children and adults in Gucha and Makueni districts were reported as severe compared to those reported in the other districts. Indirect and total costs differed significantly between districts but differences in direct costs were not significant. Total household costs were highest in Makueni (US$ 19.6 per month) and lowest in Bondo (US$ 9.2 per month). Cost burdens are the product of complex relationships between social, economic and epidemiological factors. The cost data presented in this study reflect

  10. A review of blood sample handling and pre-processing for metabolomics studies.

    PubMed

    Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta

    2017-09-01

    Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Isolation of naturally infecting Leishmania infantum from canine samples in Novy-MacNeal-Nicolle medium prepared with defibrinated blood from different animal species.

    PubMed

    Santos, Roseclea Chagas Dos; Pinho, Flaviane Alves de; Passos, Gabriela Porfírio; Larangeira, Daniela Farias; Barrouin-Melo, Stella Maria

    2018-06-15

    The most commonly used culture medium for the in vitro isolation of Leishmania spp. from canine biological samples is biphasic Novy-MacNeal-Nicolle (NNN) medium, whose solid phase is prepared using rabbit blood. Leishmania infantum parasites from natural infections are highly sensitive and demanding for growth in axenic conditions when firstly obtained from the dog's body. The objective of this study was to evaluate whether NNN medium (NNN-test) prepared with chicken blood (NNN-C), ox blood (NNN-O), horse blood (NNN-H) or sheep blood (NNN-S) was viable for the isolation of parasites from naturally infected dogs, in an endemic area for visceral leishmaniasis caused by L. infantum. Spleen aspirates from six dogs previously diagnosed as infected by parasitological methods were simultaneously inoculated in each NNN-test medium, including the conventional medium prepared with rabbit blood (NNN-R), and the cultures were examined for three weeks under optic microscopy. Spleen samples were also analyzed for parasite loads by quantitative PCR (qPCR). Cultures from three of the six dogs (50%) were positive in at least one of the NNN-test media: one sample presented the highest spleen parasite load by qPCR (1.19 × 10 4 parasites/mL) and was positive in all test media; the second sample presented parasitic isolation in the first week of culture in all inoculated media, of which the NNN-C medium had the highest mean parasite count (NNN-C = 23.5 × 10 4 /mL vs. NNN-R = 3.25 × 10 4 /mL); the third sample was positive only in the NNN-S medium besides the conventional control NNN-R. Cultures from the three remaining dogs were negative in all NNN media, including the control and test media; of those three dogs, two presented the lowest spleen parasitic loads according to qPCR. Blood from chicken, ox, horse and sheep shown to be viable for the preparation of NNN culture medium for the primary isolation of L. infantum from samples of naturally infected dogs and

  12. Brands, costs and registration status of antimalarial drugs in the Kenyan retail sector

    PubMed Central

    Amin, Abdinasir A; Snow, Robert W

    2005-01-01

    Background Although an important source of treatment for fevers, little is known about the structure of the retail sector in Africa with regard to antimalarial drugs. This study aimed to assess the range, costs, sources and registration of antimalarial drugs in the Kenyan retail sector. Methods In 2002, antimalarial drug registration and trade prices were established by triangulating national registration lists, government gazettes and trade price indices. Data on registration status and trade prices were compared with similar data generated through a retail audit undertaken among 880 randomly sampled retailers in four districts of Kenya. Results Two hundred and eighteen antimalarial drugs were in circulation in Kenya in 2002. These included 65 "sulfur"-pyrimethamine (sulfadoxine-pyrimethamine and sulfalene-pyrimethamine (SP), the first-line recommended drug in 2002) and 33 amodiaquine (AQ, the second-line recommended drug) preparations. Only half of SP and AQ products were registered with the Pharmacy and Poisons Board. Of SP and AQ brands at district level, 40% and 44% were officially within legal registration requirements. 29% of retailers at district level stocked SP and 95% stocked AQ. The retail price of adult doses of SP and AQ were on average 0.38 and 0.76 US dollars, 100% and 347% higher than trade prices from manufacturers and importers. Artemether-lumefantrine, the newly announced first-line recommended antimalarial drug in 2004, was found in less than 1% of all retail outlets at a median cost of 7.6 US dollars. Conclusion There is a need to ensure that all antimalarial drugs are registered with the Pharmacy and Poisons Board to facilitate a more stringent post-marketing surveillance system to ensure drugs are safe and of good quality post-registration. PMID:16042815

  13. Transformations in Kenyan Science Teachers' Locus of Control: The Influence of Contextualized Science and Emancipated Student Learning

    NASA Astrophysics Data System (ADS)

    Anderson, D.; Nashon, S.; Namazzi, E.; Okemwa, P.; Ombogo, P.; Ooko, S.; Beru, F.

    2015-11-01

    This study investigated Kenyan science teachers' pedagogical transformations, which manifested as they enacted and experienced a reformed contextualized science curriculum in which students' learning experiences were critical catalysts of teacher change. Twelve high school teachers voluntarily participated in the study and were interviewed about their pedagogical transformations following their enactment of a reformed contextualized science curriculum. The outcomes demonstrated that students' emancipated behaviours, learning and performance, qualitatively influenced teacher change and pedagogical reform. Specifically, changes in students, as a result of the ways the science curriculum was implemented, resulted in epiphanies and dilemmas for teachers who subsequently resolved to surrender their tightly held pedagogical control (locus of control) for the betterment of the learning environment and their sense of professional satisfaction.

  14. Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis

    PubMed Central

    Carrol, Enitan D; Salway, Fiona; Pepper, Stuart D; Saunders, Emma; Mankhambo, Limangeni A; Ollier, William E; Hart, C Anthony; Day, Phillip

    2007-01-01

    Background The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires 2.5 mL blood, which makes routine implementation impractical for paediatric use. The aim of this study was to modify the PAXgene™ Blood RNA System kit protocol for application to small, sick chidren, without compromising RNA integrity, and subsequently to perform quantitative analysis of ICAM and interleukin-6 gene expression. Aliquots of 0.86 mL PAXgene™ reagent were put into microtubes and 0.3 mL whole blood added to maintain the same recommended proportions as in the PAXgene™ evacuated tube system. RNA quality was assessed using the Agilent BioAnalyser 2100 and an in-house TaqMan™ assay which measures GAPDH transcript integrity by determining 3' to 5' ratios. qPCR analysis was performed on an additional panel of 7 housekeeping genes. Three reference genes (HPRT1, YWHAZ and GAPDH) were identified using the GeNORM algorithm, which were subsequently used to normalising target gene expression levels. ICAM-1 and IL-6 gene expression were measured in 87 Malawian children with invasive pneumococcal disease. Results Total RNA yield was between 1,114 and 2,950 ng and the BioAnalyser 2100 demonstrated discernible 18s and 28s bands. The cycle threshold values obtained for the seven housekeeping genes were between 15 and 30 and showed good consistency. Median relative ICAM and IL-6 gene expression were significantly reduced in non-survivors compared to survivors (ICAM: 3.56 vs 4.41, p = 0.04, and IL-6: 2.16 vs 6.73, p = 0.02). Conclusion We have successfully modified the PAXgene™ blood collection system for use in small children and demonstrated preservation of RNA integrity and successful quantitative real-time PCR analysis. PMID:17850649

  15. Integrated Blood Barcode Chips

    PubMed Central

    Fan, Rong; Vermesh, Ophir; Srivastava, Alok; Yen, Brian K.H.; Qin, Lidong; Ahmad, Habib; Kwong, Gabriel A.; Liu, Chao-Chao; Gould, Juliane; Hood, Leroy; Heath, James R.

    2008-01-01

    Blood comprises the largest version of the human proteome1. Changes of plasma protein profiles can reflect physiological or pathological conditions associated with many human diseases, making blood the most important fluid for clinical diagnostics2-4. Nevertheless, only a handful of plasma proteins are utilized in routine clinical tests. This is due to a host of reasons, including the intrinsic complexity of the plasma proteome1, the heterogeneity of human diseases and the fast kinetics associated with protein degradation in sampled blood5. Simple technologies that can sensitively sample large numbers of proteins over broad concentration ranges, from small amounts of blood, and within minutes of sample collection, would assist in solving these problems. Herein, we report on an integrated microfluidic system, called the Integrated Blood Barcode Chip (IBBC). It enables on-chip blood separation and the rapid measurement of a panel of plasma proteins from small quantities of blood samples including a fingerprick of whole blood. This platform holds potential for inexpensive, non-invasive, and informative clinical diagnoses, particularly, for point-of-care. PMID:19029914

  16. Effect of blood sampling schedule and method of calculating the area under the curve on validity and precision of glycaemic index values.

    PubMed

    Wolever, Thomas M S

    2004-02-01

    To evaluate the suitability for glycaemic index (GI) calculations of using blood sampling schedules and methods of calculating area under the curve (AUC) different from those recommended, the GI values of five foods were determined by recommended methods (capillary blood glucose measured seven times over 2.0 h) in forty-seven normal subjects and different calculations performed on the same data set. The AUC was calculated in four ways: incremental AUC (iAUC; recommended method), iAUC above the minimum blood glucose value (AUCmin), net AUC (netAUC) and iAUC including area only before the glycaemic response curve cuts the baseline (AUCcut). In addition, iAUC was calculated using four different sets of less than seven blood samples. GI values were derived using each AUC calculation. The mean GI values of the foods varied significantly according to the method of calculating GI. The standard deviation of GI values calculating using iAUC (20.4), was lower than six of the seven other methods, and significantly less (P<0.05) than that using netAUC (24.0). To be a valid index of food glycaemic response independent of subject characteristics, GI values in subjects should not be related to their AUC after oral glucose. However, calculating GI using AUCmin or less than seven blood samples resulted in significant (P<0.05) relationships between GI and mean AUC. It is concluded that, in subjects without diabetes, the recommended blood sampling schedule and method of AUC calculation yields more valid and/or more precise GI values than the seven other methods tested here. The only method whose results agreed reasonably well with the recommended method (ie. within +/-5 %) was AUCcut.

  17. Vascular Access Port Implantation and Serial Blood Sampling in a Gottingen Minipig (Sus scrofa domestica) Model of Acute Radiation Injury

    PubMed Central

    Moroni, Maria; Coolbaugh, Thea V; Mitchell, Jennifer M; Lombardini, Eric; Moccia, Krinon D; Shelton, Larry J; Nagy, Vitaly; Whitnall, Mark H

    2011-01-01

    Threats of nuclear and other radiologic exposures have been increasing, but no countermeasure for acute radiation syndrome has been approved by regulatory authorities. Because of their similarity to humans in regard to physiology and anatomy, we are characterizing Gottingen minipigs as a model to aid the development of radiation countermeasures. Irradiated minipigs exhibit immunosuppression, severe thrombocytopenia, vascular leakage, and acute inflammation. These complications render serial acquisition of blood samples problematic. Vascular access ports (VAP) facilitate serial sampling, but their use often is complicated by infections and fibrin deposition. We demonstrate here the successful use of VAP for multiple blood samplings in irradiated minipigs. Device design and limited postoperative prophylactic antimicrobial therapy before irradiation were key to obtaining serial sampling, reducing swelling, and eliminating infection and skin necrosis at the implantation site. Modifications of previous protocols included the use of polydioxanone sutures instead of silk; eliminating chronic port access; single-use, sterile, antireflux prefilled syringes for flushing; strict aseptic weekly maintenance of the device, and acclimating animals to reduce stress. VAP remained functional in 19 of 20 irradiated animals for as long as 3 mo. The remaining VAP failed due to a small leak in the catheter, leading to clot formation. VAP-related sepsis occurred in 2 minipigs. Blood sampling did not cause detectable stress in nonanesthetized sham-irradiated animals, according to leukograms and clinical signs. PMID:21333166

  18. Detection of sepsis in patient blood samples using CD64 expression in a microfluidic cell separation device.

    PubMed

    Zhang, Ye; Li, Wenjie; Zhou, Yun; Johnson, Amanda; Venable, Amanda; Hassan, Ahmed; Griswold, John; Pappas, Dimitri

    2017-12-18

    A microfluidic affinity separation device was developed for the detection of sepsis in critical care patients. An affinity capture method was developed to capture cells based on changes in CD64 expression in a single, simple microfluidic chip for sepsis detection. Both sepsis patient samples and a laboratory CD64+ expression model were used to validate the microfluidic assay. Flow cytometry analysis showed that the chip cell capture had a linear relationship with CD64 expression in laboratory models. The Sepsis Chip detected an increase in upregulated neutrophil-like cells when the upregulated cell population is as low as 10% of total cells spiked into commercially available aseptic blood samples. In a proof of concept study, blood samples obtained from sepsis patients within 24 hours of diagnosis were tested on the chip to further validate its performance. On-chip CD64+ cell capture from 10 patient samples (619 ± 340 cells per chip) was significantly different from control samples (32 ± 11 cells per chip) and healthy volunteer samples (228 ± 95 cells per chip). In addition, the on-chip cell capture has a linear relationship with CD64 expression indicating our approach can be used to measure CD64 expression based on total cell capture on Sepsis Chip. Our method has proven to be sensitive, accurate, rapid, and cost-effective. Therefore, this device is a promising detection platform for neutrophil activation and sepsis diagnosis.

  19. Miniaturized blood sampling techniques to benefit reduction in mice and refinement in nonhuman primates: applications to bioanalysis in toxicity studies with antibody-drug conjugates.

    PubMed

    Caron, Alexis; Lelong, Christine; Pascual, Marie-Hélène; Benning, Véronique

    2015-03-01

    Minimizing the number of animals in regulatory toxicity studies while achieving study objectives to support the development of future medicines contributes to good scientific and ethical practices. Recent advances in technology have enabled the development of miniaturized blood sampling methods (including microsampling and dried blood spots) applicable to toxicokinetic determinations of small-molecule drugs. Implementation of miniaturized blood sampling methods in the context of biotherapeutic drugs is desirable because a limitation to this type of medicine remains the total blood volume needed from a single animal to support toxicokinetic determinations of several analytes (parent drug, metabolites[s], antidrug antibodies, and so forth). We describe here the technical details, applicability, and relevance of new miniaturized blood sampling procedures in mice and nonhuman primates in the context of the toxicologic evaluation of biotherapeutic drugs consisting of antibody-drug conjugates developed for oncology indications. These examples illustrate how these techniques can benefit the reduction of animal usage in mouse toxicity studies by decreasing the number of animals dedicated to toxicokinetic determinations and the refinement of practices in nonhuman primate toxicity studies by decreasing the blood volume repeatedly drawn for toxicokinetic determinations.

  20. Miniaturized Blood Sampling Techniques to Benefit Reduction in Mice and Refinement in Nonhuman Primates: Applications to Bioanalysis in Toxicity Studies with Antibody–Drug Conjugates

    PubMed Central

    Caron, Alexis; Lelong, Christine; Pascual, Marie-Hélène; Benning, Véronique

    2015-01-01

    Minimizing the number of animals in regulatory toxicity studies while achieving study objectives to support the development of future medicines contributes to good scientific and ethical practices. Recent advances in technology have enabled the development of miniaturized blood sampling methods (including microsampling and dried blood spots) applicable to toxicokinetic determinations of small-molecule drugs. Implementation of miniaturized blood sampling methods in the context of biotherapeutic drugs is desirable because a limitation to this type of medicine remains the total blood volume needed from a single animal to support toxicokinetic determinations of several analytes (parent drug, metabolites[s], antidrug antibodies, and so forth). We describe here the technical details, applicability, and relevance of new miniaturized blood sampling procedures in mice and nonhuman primates in the context of the toxicologic evaluation of biotherapeutic drugs consisting of antibody–drug conjugates developed for oncology indications. These examples illustrate how these techniques can benefit the reduction of animal usage in mouse toxicity studies by decreasing the number of animals dedicated to toxicokinetic determinations and the refinement of practices in nonhuman primate toxicity studies by decreasing the blood volume repeatedly drawn for toxicokinetic determinations. PMID:25836960

  1. Measuring the level of agreement in hematologic and biochemical values between blood sampling sites in leatherback sea turtles (Dermochelys coriacea).

    PubMed

    Stewart, Kimberly; Mitchell, Mark A; Norton, Terry; Krecek, Rosina C

    2012-12-01

    Conservation programs to protect endangered sea turtles are being instituted worldwide. A common practice in these programs is to collect blood to evaluate the health of the turtles. Several different venipuncture sites are used to collect blood from sea turtles for hematologic and biochemistry tests, depending on the species. To date, it is unknown what affect venipuncture site may have on sample results. The purpose of this study was to measure the level of agreement between hematologic and biochemistry values collected from the dorsal cervical sinus and the interdigital vein of leatherback (Dermochelys coriacea) sea turtles. Paired heparinized blood samples were obtained from the dorsal cervical sinus and the interdigital vein of 12 adult female nesting leatherback sea turtles on Keys Beach, St. Kitts, West Indies. Even though the sample population was small, the data for each chemistry were normally distributed, except for creatine kinase (CK). There was no significant difference when comparing biochemistry or hematologic values by venipuncture site, except for CK (P = 0.02). The level of agreement between sampling sites was considered good for albumin, calcium, globulin, glucose, packed cell volume, phosphorus, potassium, sodium, total protein, total solids, uric acid, white blood cell count, and all of the individual white cell types, while the level of agreement for aspartate aminotransferase and CK were considered poor. This information, coupled with the fact that the interdigital vein affords a less-invasive procedure, demonstrates that the interdigital vein is an appropriate location to use when establishing a hematologic and biochemical profile for leatherback sea turtles.

  2. Comparability of HbA1c and lipids measured with dried blood spot versus venous samples: a systematic review and meta-analysis

    PubMed Central

    2014-01-01

    Background Levels of haemoglobin A1c (HbA1c) and blood lipids are important determinants of risk in patients with diabetes. Standard analysis methods based upon venous blood samples can be logistically challenging in resource-poor settings where much of the diabetes epidemic is occurring. Dried blood spots (DBS) provide a simple alternative method for sample collection but the comparability of data from analyses based on DBS is not well established. Methods We conducted a systematic review and meta-analysis to define the association of findings for HbA1c and blood lipids for analyses based upon standard methods compared to DBS. The Cochrane, Embase and Medline databases were searched for relevant reports and summary regression lines were estimated. Results 705 abstracts were found by the initial electronic search with 6 further reports identified by manual review of the full papers. 16 studies provided data for one or more outcomes of interest. There was a close agreement between the results for HbA1c assays based on venous and DBS samples (DBS = 0.9858venous + 0.3809), except for assays based upon affinity chromatography. Significant adjustment was required for assays of total cholesterol (DBS = 0.6807venous + 1.151) but results for triglycerides (DBS = 0.9557venous + 0.1427) were directly comparable. Conclusions For HbA1c and selected blood lipids, assays based on DBS samples are clearly associated with assays based on standard venous samples. There are, however, significant uncertainties about the nature of these associations and there is a need for standardisation of the sample collection, transportation, storage and analysis methods before the technique can be considered mainstream. This should be a research priority because better elucidation of metabolic risks in resource poor settings, where venous sampling is infeasible, will be key to addressing the global epidemic of cardiovascular diseases. PMID:25045323

  3. A one-step extraction procedure for the screening of cocaine, amphetamines and cannabinoids in postmortem blood samples.

    PubMed

    Pelição, Fabrício Souza; Peres, Mariana Dadalto; Pissinate, Jauber Fornaciari; De Martinis, Bruno Spinosa

    2014-01-01

    A gas chromatography-mass spectrometric (GC-MS) method was developed and validated for the simultaneous detection and quantification in postmortem whole blood samples of cocaine (COC), amphetamines (AMPs) and cannabis; the main drugs involved in cases of impaired driving in Brazil. The analytes were extracted by solid-phase extraction by means of Bond-Elute Certify cartridges, derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide at 80°C for 30 min and analyzed by GC-MS. Linearity ranged from 10 to 500 ng/mL, except for ecgonine methyl ester, for which linearity ranged from 10 to 100 ng/mL. Inter- and intra-day imprecision ranged from 2.8 to 18.4% and from 1.5 to 14.9%, respectively. Accuracy values lay between 86.9 and 104.4%. The limit of quantitation for all drugs was 10 ng/mL and recoveries were >74% for all analytes, except for cannabinoids, which showed poor recovery (∼30%). The developed method was applied to real samples collected from deceased victims due to traffic accidents. These samples were selected according to the results obtained in immunoassay screening on collected urine samples. Five samples were positive for the presence of COC and metabolites, four samples were positive for cannabinoids, six samples were positive for AMPs and two samples were drug negative. Some samples were positive for more than one class of drug. Results obtained from whole blood samples showed good agreement with urine screening. The developed method proved capable of quantifying all three classes of drugs of abuse proposed in this study, through a one-step extraction procedure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyle, Jennifer E.; Casey, Cameron P.; Stratton, Kelly G.

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules weremore » identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.« less

  5. Malaria and Chikungunya Detected Using Molecular Diagnostics Among Febrile Kenyan Children.

    PubMed

    Waggoner, Jesse; Brichard, Julie; Mutuku, Francis; Ndenga, Bryson; Heath, Claire Jane; Mohamed-Hadley, Alisha; Sahoo, Malaya K; Vulule, John; Lefterova, Martina; Banaei, Niaz; Mukoko, Dunstan; Pinsky, Benjamin A; LaBeaud, A Desiree

    2017-01-01

    In sub-Saharan Africa, malaria is frequently overdiagnosed as the cause of an undifferentiated febrile illness, whereas arboviral illnesses are presumed to be underdiagnosed. Sera from 385 febrile Kenyan children, who presented to 1 of 4 clinical sites, were tested using microscopy and real-time molecular assays for dengue virus (DENV), chikungunya virus (CHIKV), malaria, and Leptospira . Malaria was the primary clinical diagnosis for 254 patients, and an arboviral infection (DENV or CHIKV) was the primary diagnosis for 93 patients. In total, 158 patients (41.0%) had malaria and 32 patients (8.3%) had CHIKV infections. Compared with real-time polymerase chain reaction, microscopy demonstrated a percent positive agreement of 49.7%. The percentage of malaria cases detected by microscopy varied significantly between clinical sites. Arboviral infections were the clinical diagnosis for patients on the Indian Ocean coast (91 of 238, 38.2%) significantly more often than patients in the Lake Victoria region (2 of 145, 1.4%; P < .001). However, detection of CHIKV infections was significantly higher in the Lake Victoria region (19 of 145 [13.1%] vs 13 of 239 [5.4%]; P = .012). The clinical diagnosis of patients with an acute febrile illness, even when aided by microscopy, remains inaccurate in malaria-endemic areas, contributing to inappropriate management decisions.

  6. Comparing dried and liquid blood serum samples of depressed patients: An analysis by Raman and infrared spectroscopy methods.

    PubMed

    Depciuch, J; Parlinska-Wojtan, M

    2018-02-20

    Depression is a serious mental illness. To study the mechanism of depression and search for new, more effective therapies, animal models are often used. Unfortunately, none of the available models reflects all the symptoms of depression. Therefore researchers are looking for new tools to diagnose depression. Unfortunately, the nowadays-available depression diagnosis methods are only psychological tests. However, it is known, that the amount of phospholipids, proteins and lipids decreases during depression. Raman and FTIR (Fourier Transform Infra Red) spectroscopies provide information on the chemical compounds in the measured sample e.g. blood serum. These spectroscopic techniques may thus become reliable and accurate tools for evaluating changes in the amount of phospholipids and proteins in depression disease. In this study differences between dried and liquid blood serum samples of healthy and depressed individuals measured by Raman (range 0-3000cm -1 ) and FTIR (Fourier Transform Infrared) (range 900-3000cm -1 ) spectroscopy were evaluated. The resulting spectra and accurate analysis led to the conclusion that an appropriate measurement of the background and the elimination of peaks from water had the greatest impact on the reliability of the results. Furthermore, after detailed studies of FTIR and Raman spectra of dried and liquid blood serum samples, including a complete analysis of peaks after Kramers-Kröning (KK) transformation, it was found that the sample preparation did not affect the results obtained by Raman spectroscopy. In FTIR measurements only a minimal effect on peak intensity was observed. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. The best practice for preparation of samples from FTA®cards for diagnosis of blood borne infections using African trypanosomes as a model system.

    PubMed

    Ahmed, Heba A; MacLeod, Ewan T; Hide, Geoff; Welburn, Susan C; Picozzi, Kim

    2011-05-07

    Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach.

  8. The best practice for preparation of samples from FTA®cards for diagnosis of blood borne infections using African trypanosomes as a model system

    PubMed Central

    2011-01-01

    Background Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. Results A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Conclusions Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach. PMID:21548975

  9. Determination of proflavine in rat whole blood without sample pretreatment by laser desorption postionization mass spectrometry.

    PubMed

    Chen, Jiaxin; Hu, Yongjun; Lu, Qiao; Wang, Pengchao; Zhan, Huaqi

    2017-04-01

    A novel pretreatment-free method involving laser desorption postionization (LDPI) coupled with time-of-flight mass spectrometry (MS) was developed for the monitoring of proflavine level in rat whole blood. It comprises a protocol for dosing via intravenous administration and collection of whole blood, followed by direct LDPI-MS analysis without any sample pretreatment. An intense ion signal at m/z 209 was observed from whole blood without any interference signals, except some background signals below m/z 100. The calibration curve was established with use of 9-phenylacridine as the internal standard for proflavine determination from the plotting of the peak ratios of proflavine to the internal standard, with a correlation coefficient (R 2 ) greater than 0.99. The limit of detection was estimated to be 0.48 pmol/mm 2 and the quantification range was 0.5-16.5 μg/mL for proflavine. In addition, only a minimal matrix effect was observed, as expected from considerations of the desorption and ionization mechanism. Interday and intraday accuracy and precision were calculated to be within 13% and 82-114%, respectively. Estimated concentrations of proflavine residue in whole blood were also successfully obtained at selected time points after dosing. The proposed method is simple, low cost, and sensitive, and should be seen as a complementary method for monitoring drug levels in blood. Graphical Abstract Monitoring proflavine levels in rat whole blood at different time points using laser desorption postionization mass spectrometry (LDPI-MS).

  10. Rapid and Sensitive Salmonella Typhi Detection in Blood and Fecal Samples Using Reverse Transcription Loop-Mediated Isothermal Amplification.

    PubMed

    Fan, Fenxia; Yan, Meiying; Du, Pengcheng; Chen, Chen; Kan, Biao

    2015-09-01

    Typhoid fever caused by Salmonella enterica serovar Typhi remains a significant public health problem in developing countries. Although the main method for diagnosing typhoid fever is blood culture, the test is time consuming and not always able to detect infections. Thus, it is very difficult to distinguish typhoid from other infections in patients with nonspecific symptoms. A simple and sensitive laboratory detection method remains necessary. The purpose of this study is to establish and evaluate a rapid and sensitive reverse transcription-based loop-mediated isothermal amplification (RT-LAMP) method to detect Salmonella Typhi infection. In this study, a new specific gene marker, STY1607, was selected to develop a STY1607-RT-LAMP assay; this is the first report of specific RT-LAMP detection assay for typhoid. Human-simulated and clinical blood/stool samples were used to evaluate the performance of STY1607-RT-LAMP for RNA detection; this method was compared with STY1607-LAMP, reverse transcription real-time polymerase chain reaction (rRT-PCR), and bacterial culture methods for Salmonella Typhi detection. Using mRNA as the template, STY1607-RT-LAMP exhibited 50-fold greater sensitivity than STY1607-LAMP for DNA detection. The STY1607-RT-LAMP detection limit is 3 colony-forming units (CFU)/mL for both the pure Salmonella Typhi samples and Salmonella Typhi-simulated blood samples and was 30 CFU/g for the simulated stool samples, all of which were 10-fold more sensitive than the rRT-PCR method. RT-LAMP exhibited improved Salmonella Typhi detection sensitivity compared to culture methods and to rRT-PCR of clinical blood and stool specimens from suspected typhoid fever patients. Because it can be performed without sophisticated equipment or skilled personnel, RT-LAMP is a valuable tool for clinical laboratories in developing countries. This method can be applied in the clinical diagnosis and care of typhoid fever patients as well as for a quick public health response.

  11. Molecular detection of vector-borne pathogens in blood and splenic samples from dogs with splenic disease.

    PubMed

    Movilla, Rebeca; Altet, Laura; Serrano, Lorena; Tabar, María-Dolores; Roura, Xavier

    2017-03-13

    The spleen is a highly perfused organ involved in the immunological control and elimination of vector-borne pathogens (VBP), which could have a fundamental role in the pathogenesis of splenic disease. This study aimed to evaluate certain VBP in samples from dogs with splenic lesions. Seventy-seven EDTA-blood and 64 splenic tissue samples were collected from 78 dogs with splenic disease in a Mediterranean area. Babesia spp., Bartonella spp., Ehrlichia/Anaplasma spp., Hepatozoon canis, Leishmania infantum, hemotropic Mycoplasma spp. and Rickettsia spp. were targeted using PCR assays. Sixty EDTA-blood samples from dogs without evidence of splenic lesions were included as a control group. More than half (51.56%) of the biopsies (33/64) were consistent with benign lesions and 48.43% (31/64) with malignancy, mostly hemangiosarcoma (25/31). PCR yielded positive results in 13 dogs with spleen alterations (16.67%), for Babesia canis (n = 3), Babesia gibsoni (n = 2), hemotropic Mycoplasma spp. (n = 2), Rickettsia massiliae (n = 1) and "Babesia vulpes" (n = 1), in blood; and for B. canis, B. gibsoni, Ehrlichia canis and L. infantum (n = 1 each), in spleen. Two control dogs (3.3%) were positive for B. gibsoni and H. canis (n = 1 each). Benign lesions were detected in the 61.54% of infected dogs (8/13); the remaining 38.46% were diagnosed with malignancies (5/13). Infection was significantly associated to the presence of splenic disease (P = 0.013). There was no difference in the prevalence of infection between dogs with benign and malignant splenic lesions (P = 0.69); however B. canis was more prevalent in dogs with hemangiosarcoma (P = 0.006). VBP infection could be involved in the pathogenesis of splenic disease. The immunological role of the spleen could predispose to alterations of this organ in infected dogs. Interestingly, all dogs with B. canis infection were diagnosed with hemangiosarcoma in the present survey. As previously

  12. Simplifying [18F]GE-179 PET: are both arterial blood sampling and 90-min acquisitions essential?

    PubMed

    McGinnity, Colm J; Riaño Barros, Daniela A; Trigg, William; Brooks, David J; Hinz, Rainer; Duncan, John S; Koepp, Matthias J; Hammers, Alexander

    2018-06-11

    The NMDA receptor radiotracer [ 18 F]GE-179 has been used with 90-min scans and arterial plasma input functions. We explored whether (1) arterial blood sampling is avoidable and (2) shorter scans are feasible. For 20 existing [ 18 F]GE-179 datasets, we generated (1) standardised uptake values (SUVs) over eight intervals; (2) volume of distribution (V T ) images using population-based input functions (PBIFs), scaled using one parent plasma sample; and (3) V T images using three shortened datasets, using the original parent plasma input functions (ppIFs). Correlations with the original ppIF-derived 90-min V T s increased for later interval SUVs (maximal ρ = 0.78; 80-90 min). They were strong for PBIF-derived V T s (ρ = 0.90), but between-subject coefficient of variation increased. Correlations were very strong for the 60/70/80-min original ppIF-derived V T s (ρ = 0.97-1.00), which suffered regionally variant negative bias. Where arterial blood sampling is available, reduction of scan duration to 60 min is feasible, but with negative bias. The performance of SUVs was more consistent across participants than PBIF-derived V T s.

  13. Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran

    PubMed Central

    MOHAMMADALI, Fatemeh; POURFATHOLLAH, Aliakbar

    2014-01-01

    Abstract Background The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. Methods This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Results Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P <0.05) ; percentage of HIV Ag/Ab was higher in donors who had blood group “A” and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Conclusion Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low. PMID:25909065

  14. Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran.

    PubMed

    Mohammadali, Fatemeh; Pourfathollah, Aliakbar

    2014-07-01

    The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P <0.05) ; percentage of HIV Ag/Ab was higher in donors who had blood group "A" and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low.

  15. Evaluation of automated loop-mediated amplification (LAMP) for routine malaria detection in blood samples of German travelers - A cross-sectional study.

    PubMed

    Frickmann, Hagen; Hinz, Rebecca; Rojak, Sandra; Bonow, Insa; Ruben, Stefanie; Wegner, Christine; Zielke, Iris; Hagen, Ralf Matthias; Tannich, Egbert

    2018-05-12

    We assessed a commercial loop-mediated amplification (LAMP) platform for its reliability as a screening tool for malaria parasite detection. A total of 1000 blood samples from patients with suspected or confirmed malaria submitted to the German National Reference Center for Tropical Pathogens were subjected to LAMP using the Meridian illumigene Malaria platform. Results were compared with microscopy from thick and thin blood films in all cases. In case of discordant results between LAMP and microscopy (n = 60), confirmation testing was performed with real-time PCR. Persistence of circulating parasite DNA was analyzed by serial assessments of blood samples following malaria treatment. Out of 1000 blood samples analyzed, 238 were positive for malaria parasites according to microscopy (n = 181/1000) or PCR (additional n = 57/60). LAMP demonstrated sensitivity of 98.7% (235/238), specificity of 99.6% (759/762), positive predictive value (PPV) of 98.7% (235/238) and negative predictive value (NPV) of 99.6% (759/762), respectively. For first slides of patients with malaria and for follow-up slides, sensitivity values were 99.1% (106/107) and 98.5% (129/131), respectively. The performance of the Meridian illumigene Malaria platform is suitable for initial screening of patients suspected of clinical malaria. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. High Levels of Asymptomatic and Subpatent Plasmodium falciparum Parasite Carriage at Health Facilities in an Area of Heterogeneous Malaria Transmission Intensity in the Kenyan Highlands

    PubMed Central

    Stresman, Gillian H.; Stevenson, Jennifer C.; Ngwu, Nnenna; Marube, Elizabeth; Owaga, Chrispin; Drakeley, Chris; Bousema, Teun; Cox, Jonathan

    2014-01-01

    In endemic settings, health facility surveys provide a convenient approach to estimating malaria transmission intensity. Typically, testing for malaria at facilities is performed on symptomatic attendees, but asymptomatic infections comprise a considerable proportion of the parasite reservoir. We sampled individuals attending five health facilities in the western Kenyan highlands. Malaria prevalence by rapid diagnostic test (RDT) was 8.6–32.9% in the health facilities. Of all polymerase chain reaction-positive participants, 46.4% (95% confidence interval [95% CI] = 42.6–50.2%) of participants had infections that were RDT-negative and asymptomatic, and 55.9% of those infections consisted of multiple parasite clones as assessed by merozoite surface protein-2 genotyping. Subpatent infections were more common in individuals reporting the use of non-artemisinin–based antimalarials in the 2 weeks preceding the survey (odds ratio = 2.49, 95% CI = 1.04–5.92) compared with individuals not reporting previous use of antimalarials. We observed a large and genetically complex pool of subpatent parasitemia in the Kenya highlands that must be considered in malaria interventions. PMID:25331807

  17. Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses.

    PubMed

    Lange, Berit; Cohn, Jennifer; Roberts, Teri; Camp, Johannes; Chauffour, Jeanne; Gummadi, Nina; Ishizaki, Azumi; Nagarathnam, Anupriya; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Easterbrook, Philippa; Denkinger, Claudia M

    2017-11-01

    Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy

  18. Lead levels - blood

    MedlinePlus

    Blood lead levels ... A blood sample is needed. Most of the time blood is drawn from a vein located on the inside ... may be used to puncture the skin. The blood collects in a small glass tube called a ...

  19. A strategy to increase adoption of locally-produced, ceramic cookstoves in rural Kenyan households

    PubMed Central

    2012-01-01

    Background Exposure to household air pollutants released during cooking has been linked to numerous adverse health outcomes among residents of rural areas in low-income countries. Improved cookstoves are one of few available interventions, but achieving equity in cookstove access has been challenging. Therefore, innovative approaches are needed. To evaluate a project designed to motivate adoption of locally-produced, ceramic cookstoves (upesi jiko) in an impoverished, rural African population, we assessed the perceived benefits of the cookstoves (in monetary and time-savings terms), the rate of cookstove adoption, and the equity of adoption. Methods The project was conducted in 60 rural Kenyan villages in 2008 and 2009. Baseline (n = 1250) and follow-up (n = 293) surveys and a stove-tracking database were analyzed. Results At baseline, nearly all respondents used wood (95%) and firepits (99%) for cooking; 98% desired smoke reductions. Households with upesi jiko subsequently spent <100 Kenyan Shillings/week on firewood more often (40%) than households without upesi jiko (20%) (p = 0.0002). There were no significant differences in the presence of children <2 years of age in households using upesi jiko (48%) or three-stone stoves (49%) (p = 0.88); children 2–5 years of age were less common in households using upesi jiko versus three-stone stoves (46% and 69%, respectively) (p = 0.0001). Vendors installed 1,124 upesi jiko in 757 multi-family households in 18 months; 68% of these transactions involved incentives for vendors and purchasers. Relatively few (<10%) upesi jiko were installed in households of women in the youngest age quartile (<22 years) or among households in the poorest quintile. Conclusions Our strategy of training of local vendors, appropriate incentives, and product integration effectively accelerated cookstove adoption into a large number of households. The strategy also created opportunities to reinforce health messages

  20. Systemic Metabolomic Changes in Blood Samples of Lung Cancer Patients Identified by Gas Chromatography Time-of-Flight Mass Spectrometry

    PubMed Central

    Miyamoto, Suzanne; Taylor, Sandra L.; Barupal, Dinesh K.; Taguchi, Ayumu; Wohlgemuth, Gert; Wikoff, William R.; Yoneda, Ken Y.; Gandara, David R.; Hanash, Samir M.; Kim, Kyoungmi; Fiehn, Oliver

    2015-01-01

    Lung cancer is a leading cause of cancer deaths worldwide. Metabolic alterations in tumor cells coupled with systemic indicators of the host response to tumor development have the potential to yield blood profiles with clinical utility for diagnosis and monitoring of treatment. We report results from two separate studies using gas chromatography time-of-flight mass spectrometry (GC-TOF MS) to profile metabolites in human blood samples that significantly differ from non-small cell lung cancer (NSCLC) adenocarcinoma and other lung cancer cases. Metabolomic analysis of blood samples from the two studies yielded a total of 437 metabolites, of which 148 were identified as known compounds and 289 identified as unknown compounds. Differential analysis identified 15 known metabolites in one study and 18 in a second study that were statistically different (p-values <0.05). Levels of maltose, palmitic acid, glycerol, ethanolamine, glutamic acid, and lactic acid were increased in cancer samples while amino acids tryptophan, lysine and histidine decreased. Many of the metabolites were found to be significantly different in both studies, suggesting that metabolomics appears to be robust enough to find systemic changes from lung cancer, thus showing the potential of this type of analysis for lung cancer detection. PMID:25859693

  1. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    PubMed Central

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  2. Influence of blood sampling methods on dopamine-receptor-blocking activities as determined by a radioreceptor assay.

    PubMed

    Lai, A A; Fleck, R J; Patzke, J V; Glueck, B G; Shaskan, E G; Rosenberg, B J

    1982-01-01

    The influence of blood collection methods on dopamine-receptor-blocking activities as determined by a radioreceptor assay kit was investigated. Thirty-one patients treated with one of six neuroleptic drugs (thioridazine, trifluoperazine, haloperidol, chlorpromazine, thiothixene, or fluphenazine) participated in this study. Blood samples were drawn from each patient into five different evacuated blood collection tubes made by the same manufacturer (red-stoppered tube containing no additives, lavender-stoppered tube containing EDTA, green-stoppered tube containing heparin, dark blue-stoppered tube containing no additives, and dark blue-stoppered tube containing heparin). The results show that for five drugs (chlorpromazine, fluphenazine, haloperidol, thiothixene, and trifluoperazine), the dark blue-stoppered tubes without additives resulted in significantly higher dopamine-receptor-blocking activities than the red-, lavender-, or green-stoppered tubes. For thioridazine, the green-stoppered tubes resulted in significantly higher blocking activities than the blue- and red-stoppered tubes. The possible effect of tris(2-butoxyethyl) phosphate, a plasticizer, on dopamine-receptor-blocking activities by neuroleptic drugs is discussed.

  3. Sensitivity and Specificity of an Operon Immunochromatographic Test in Serum and Whole-Blood Samples for the Diagnosis of Trypanosoma cruzi Infection in Spain, an Area of Nonendemicity

    PubMed Central

    Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio

    2012-01-01

    Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296

  4. Blood pressure interacts with APOE ε4 to predict memory performance in a midlife sample.

    PubMed

    Oberlin, Lauren E; Manuck, Stephen B; Gianaros, Peter J; Ferrell, Robert E; Muldoon, Matthew F; Jennings, J Richard; Flory, Janine D; Erickson, Kirk I

    2015-09-01

    Elevated blood pressure and the Apolipoprotein ε4 allele (APOE ε4) are independent risk factors for Alzheimer's disease. We sought to determine whether the combined presence of the APOE ε4 allele and elevated blood pressure is associated with lower cognitive performance in cognitively healthy middle-aged adults. A total of 975 participants aged 30-54 (mean age = 44.47) were genotyped for APOE. Cardiometabolic risk factors including blood pressure, lipids, and glucose were assessed and cognitive function was measured using the Trail Making Test and the Visual Reproduction and Logical Memory subtests from the Wechsler Memory Scale. Multivariable regression analysis showed that the association between APOE ε4 and episodic memory performance varied as a function of systolic blood pressure (SBP), such that elevated SBP was predictive of poorer episodic memory performance only in APOE ε4 carriers (β = -.092; t = -2.614; p = .009). Notably, this association was apparent at prehypertensive levels (≥130 mmHg), even after adjusting for physical activity, depression, smoking, and other cardiometabolic risk factors. The joint presence of APOE ε4 and elevated SBP, even at prehypertensive levels, is associated with lower cognitive performance in healthy, middle-aged adults. Results of this study suggest that the combination of APOE ε4 and elevated SBP may synergistically compromise memory function well before the appearance of clinically significant impairments. Interventions targeting blood pressure control in APOE ε4 carriers during midlife should be studied as a possible means to reduce the risk of cognitive decline in genetically susceptible samples. (c) 2015 APA, all rights reserved).

  5. Monitoring of cyclosporine concentrations by using dry blood-spot samples.

    PubMed

    Mee, A V; Wong, P Y; Sun, C; Oei, L; Elliott, S; Naik, N; Joaquin, B; Uchimaru, D

    1991-01-01

    We modified the Incstar Cyclo Trac SP kit to enable its use with dry blood-spots on filter paper. The recovery ranged from 92 to 106%. Dilution studies have shown excellent linearity and parallelism throughout the range of the assay. Precision is demonstrated by within-assay CV's of 6.6 and 4.3% at 96 and 342 micrograms/L respectively and between-assay CV's of 9.1 and 7.0% at 138 and 506 micrograms/L respectively. A comparison study (n = 209) with whole blood assay gave a correlation coefficient of 0.97, a slope of 1.04, and an intercept of 13.2. Whole blood and dry blood-spot cyclosporine assays on heart, kidney, liver, and lung transplants were also compared.

  6. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    PubMed

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  7. Identification of malaria infected red blood samples by digital holographic quantitative phase microscope

    NASA Astrophysics Data System (ADS)

    Patel, Nimit R.; Chhaniwal, Vani K.; Javidi, Bahram; Anand, Arun

    2015-07-01

    Development of devices for automatic identification of diseases is desired especially in developing countries. In the case of malaria, even today the gold standard is the inspection of chemically treated blood smears through a microscope. This requires a trained technician/microscopist to identify the cells in the field of view, with which the labeling chemicals gets attached. Bright field microscopes provide only low contrast 2D images of red blood cells and cell thickness distribution cannot be obtained. Quantitative phase contrast microscopes can provide both intensity and phase profiles of the cells under study. The phase information can be used to determine thickness profile of the cell. Since cell morphology is available, many parameters pertaining to the 3D shape of the cell can be computed. These parameters in turn could be used to decide about the state of health of the cell leading to disease diagnosis. Here the investigations done on digital holographic microscope, which provides quantitative phase images, for comparison of parameters obtained from the 3D shape profile of objects leading to identification of diseased samples is described.

  8. Concentrations of persistent organic pollutants (POPs) in human blood samples from Mexico City, Mexico.

    PubMed

    Orta-García, Sandra; Pérez-Vázquez, Francisco; González-Vega, Carolina; Varela-Silva, José Antonio; Hernández-González, Lidia; Pérez-Maldonado, Iván

    2014-02-15

    Studies in Mexico have demonstrated exposure to persistent organic pollutants (POPs) in people living in different sites through the country. However, studies evaluating exposure to POPs in people living in Mexico City (one of most contaminated places in the world) are scarce. Therefore, the aim of this study was to assess the levels of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), dichlorodiphenyltrichloroethane (DDT) and its metabolite dichlorodiphenyldichloroethylene (DDE) in the blood as exposure biomarkers in people living in Mexico City. A total of 123 participants (blood donors aged 20-60 years) were recruited during 2010 in Mexico City. Quantitative analyses of blood samples were performed using gas chromatography coupled with mass spectrometry. Levels of the assessed compounds ranged from non-detectable (

  9. Optimised cord blood sample selection for small‑scale CD34+ cell immunomagnetic isolation.

    PubMed

    Perdomo-Arciniegas, Ana-María; Vernot, Jean-Paul

    2012-03-01

    Haematopoietic stem cells (HSCs) are defined as multipotential cells, capable of self-renewal and reconstituting in vivo the haematopoietic compartment. The CD34 antigen is considered an important HSCs marker in humans. Immunomagnetic isolation, by targeting CD34 antigen, is widely used for human HSC separation. This method allows the enrichment of human HSCs that are present at low frequencies in umbilical cord blood (CB). Immunomagnetic CD34+-cell isolation reproducibility, regarding cell yield and purity, is affected by the CD34+ cell frequency and total cell numbers present in a given sample; CB HSC purification may thus yield variable results, which also depend on the volume and density fractionation-derived cell loss of a CB sample. The uncertainty of such an outcome and associated technical costs call for a cost-effective sample screening strategy. A correlation analysis using clinical and laboratory data from 59 CB samples was performed to establish predictive variables for CD34+-immunomagnetic HSCs isolation. This study described the positive association of CD34+-cell isolation with white and red cell numbers present after cell fractionation. Furthermore, purity has been correlated with lymphocyte percentages. Predictive variable cut-off values, which are particularly useful in situations involving low CB volumes being collected (such as prevalent late umbilical cord clamping clinical practice), were proposed for HSC isolation sampling. Using the simple and cost-effective CB sample screening criteria described here would lead to avoiding costly inefficient sample purification, thereby ensuring that pure CD34+ cells are obtained in the desired numbers following CD34 immunomagnetic isolation.

  10. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    PubMed

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  11. Pharmacokinetic-pharmacodynamic study of subcutaneous injection of depot nandrolone decanoate using dried blood spots sampling coupled with ultrapressure liquid chromatography tandem mass spectrometry assays.

    PubMed

    Singh, Gurmeet K S; Turner, Leo; Desai, Reena; Jimenez, Mark; Handelsman, David J

    2014-07-01

    Testosterone (T) and nandrolone (N) esters require deep im injections by medical personnel but these often deposit injectate into sc fat so that more convenient sc self-administration may be feasible. To investigate the feasibility and pharmacology of sc injection of N decanoate in healthy men using dried blood spot (DBS) for frequent blood sampling without clinic visits. Healthy male volunteers received 100 mg N decanoate by a single sc injection. Finger-prick capillary blood was spotted onto filter paper before injection daily at home for 21 d and stored at room temperature. Venous whole blood was also spotted onto filter paper before and weekly for 3 wk after injection. DBS were extracted for assay of N and T by liquid chromatography tandem mass spectrometry in a single batch with serum concentrations estimated with adjustment for capillary blood sample volume and hematocrit to define peak (N) or nadir (T) time and concentration from individual daily measurements. Daily serum N peaked 2.50 ± 0.25 (SEM) ng/mL at a median (range) of 6 (4-13) days causing a reduction in serum T from 3.50 ± 0.57 ng/mL at baseline to a nadir of 0.38 ± 0.13 (SEM) ng/mL (89 ± 3% suppression) at a median (range) of 8 (5-16) days. Simultaneously sampled capillary, venous whole blood, and serum gave almost identical results for serum T and N. Finger-pricks and sc injections were well tolerated. This study demonstrates that A) DBS sampling with liquid chromatography mass spectrometry steroid analysis achieves frequent time sampling in the community without requiring clinic visits, venesection, or frozen serum storage, and B) androgen esters in an oil vehicle can be delivered effectively by sc injection, thus avoiding the need for medically supervised deep-im injections.

  12. Effect of Environmental and Behavioral Interventions on Pain Intensity in Preterm Infants for Heel Prick Blood Sampling in the Neonatal Intensive Care Unit.

    PubMed

    Baharlooei, Fatemeh; Marofi, Maryam; Abdeyazdan, Zahra

    2017-01-01

    Recent researches suggest that preterm infants understand pain and stress. Because of the wide range of effects of pain on infants, the present study was conducted on the effect of environmental and behavioral interventions on pain due to heel-prick blood sampling in preterm infants. A clinical trial was conducted among 32 infants with gestational age of 32-37 weeks in the intervention and control groups. The effects of noise reduction by earplugs, light reduction by blindfolds, reduction of nursing manipulation, and creation of intrauterine position for neonates, 30 minutes before taking blood samples until 30 minutes after it, were measured during the intervention stage. Data were collected using the Neonatal Infant Pain Scale (NIPS) in 5 stages (before intervention, 2 minutes before sampling, during the sampling, and 5 minutes and 30 minutes after the sampling). The data were analyzed using analysis of variance (ANOVA) and paired t -test in SPSS software. The paired t -test results showed no significant differences between the control and intervention stages in terms of pain scores at base time ( P = 0.42) and 2 minutes before sampling ( P = 0.12). However, at the sampling time ( P = 0.0), and 5 minutes ( P = 0.001) and 30 minutes after the sampling ( P = 0.001), mean pain score in the intervention stage was significantly less than that in the control stage. Based on the findings, environmental and behavioral interventions reduced pain and facilitated heel-prick blood sampling in preterm infants.

  13. Alcohol intoxication at Swedish football matches: A study using biological sampling to assess blood alcohol concentration levels among spectators.

    PubMed

    Durbeej, Natalie; Elgán, Tobias H; Jalling, Camilla; Gripenberg, Johanna

    2017-01-01

    Alcohol use and alcohol-related problems, including accidents, vandalism and violence, at sporting events are of increased concern in Sweden and other countries. The relationship between alcohol use and violence has been established and can be explained by the level of intoxication. Given the occurrence of alcohol use and alcohol-related problems at sporting events, research has assessed intoxication levels measured through biological sampling among spectators. This cross-sectional study aimed to assess the level of alcohol intoxication among spectators at football matches in the Swedish Premier Football League. Spectators were randomly selected and invited to participate in the study. Alcohol intoxication was measured with a breath analyser for Blood Alcohol Concentration levels, and data on gender, age, and recent alcohol use were gathered through a face-to-face interview. Blood Alcohol Concentration samples from 4420 spectators were collected. Almost half (46.8%) had a positive Blood Alcohol Concentration level, with a mean value of 0.063%, while 8.9% had a Blood Alcohol Concentration level ≥ 0.1%, with a mean value of 0.135%. Factors that predicted a higher Blood Alcohol Concentration level included male gender (p = 0.005), lower age (p < 0.001), attending a local derby (p < 0.001), alcohol use prior to having entered the arena (p < 0.001), attending a weekend match (p < 0.001), and being a spectator at supporter sections (p < 0.001). About half of all spectators at football matches in the Swedish Premier Football League drink alcohol in conjunction with the match. Approximately one tenth have a high level of alcohol intoxication.

  14. Age-specific discrimination of blood plasma samples of healthy and ovarian cancer prone mice using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Melikechi, Noureddine; Markushin, Yuri; Connolly, Denise C.; Lasue, Jeremie; Ewusi-Annan, Ebo; Makrogiannis, Sokratis

    2016-09-01

    Epithelial ovarian cancer (EOC) mortality rates are strongly correlated with the stage at which it is diagnosed. Detection of EOC prior to its dissemination from the site of origin is known to significantly improve the patient outcome. However, there are currently no effective methods for early detection of the most common and lethal subtype of EOC. We sought to determine whether laser-induced breakdown spectroscopy (LIBS) and classification techniques such as linear discriminant analysis (LDA) and random forest (RF) could classify and differentiate blood plasma specimens from transgenic mice with ovarian carcinoma and wild type control mice. Herein we report results using this approach to distinguish blood plasma samples obtained from serially bled (at 8, 12, and 16 weeks) tumor-bearing TgMISIIR-TAg transgenic and wild type cancer-free littermate control mice. We have calculated the age-specific accuracy of classification using 18,000 laser-induced breakdown spectra of the blood plasma samples from tumor-bearing mice and wild type controls. When the analysis is performed in the spectral range 250 nm to 680 nm using LDA, these are 76.7 (± 2.6)%, 71.2 (± 1.3)%, and 73.1 (± 1.4)%, for the 8, 12 and 16 weeks. When the RF classifier is used, we obtain values of 78.5 (± 2.3)%, 76.9 (± 2.1)% and 75.4 (± 2.0)% in the spectral range of 250 nm to 680 nm, and 81.0 (± 1.8)%, 80.4 (± 2.1)% and 79.6 (± 3.5)% in 220 nm to 850 nm. In addition, we report, the positive and negative predictive values of the classification of the two classes of blood plasma samples. The approach used in this study is rapid, requires only 5 μL of blood plasma, and is based on the use of unsupervised and widely accepted multivariate analysis algorithms. These findings suggest that LIBS and multivariate analysis may be a novel approach for detecting EOC.

  15. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) and dried blood spot sampling applied to pharmacokinetics studies in animals: Correlation of classic and block design.

    PubMed

    Baldo, Matías N; Angeli, Emmanuel; Gareis, Natalia C; Hunzicker, Gabriel A; Murguía, Marcelo C; Ortega, Hugo H; Hein, Gustavo J

    2018-04-01

    A relative bioavailability study (RBA) of two phenytoin (PHT) formulations was conducted in rabbits, in order to compare the results obtained from different matrices (plasma and blood from dried blood spot (DBS) sampling) and different experimental designs (classic and block). The method was developed by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in plasma and blood samples. The different sample preparation techniques, plasma protein precipitation and DBS, were validated according to international requirements. The analytical method was validated with ranges 0.20-50.80 and 0.12-20.32 µg ml -1 , r > 0.999 for plasma and blood, respectively. Accuracy and precision were within acceptance criteria for bioanalytical assay validation (< 15 for bias and CV% and < 20 for limit of quantification (LOQ)). PHT showed long-term stability, both for plasma and blood, and under refrigerated and room temperature conditions. Haematocrit values were measured during the validation process and RBA study. Finally, the pharmacokinetic parameters (C max , T max and AUC 0-t ) obtained from the RBA study were tested. Results were highly comparable for matrices and experimental designs. A matrix correlation higher than 0.975 and a ratio of (PHT blood) = 1.158 (PHT plasma) were obtained. The results obtained herein show that the use of classic experimental design and DBS sampling for animal pharmacokinetic studies should be encouraged as they could help to prevent the use of a large number of animals and also animal euthanasia. Finally, the combination of DBS sampling with LC-MS/MS technology showed to be an excellent tool not only for therapeutic drug monitoring but also for RBA studies.

  16. Multiplexed flow cytometric sensing of blood electrolytes in physiological samples using fluorescent bulk optode microspheres.

    PubMed

    Xu, Chao; Wygladacz, Katarzyna; Retter, Robert; Bell, Michael; Bakker, Eric

    2007-12-15

    Polymeric bulk optode microsphere ion sensors in combination with suspension array technologies such as analytical flow cytometry may become a power tool for measuring electrolytes in physiological samples. In this work, the methodology for the direct measurement of common blood electrolytes in physiological samples using bulk optode microsphere sensors was explored. The simultaneous determination of Na(+), K(+), and Ca(2+) in diluted sheep blood plasma was demonstrated for the first time, using a random suspension array containing three types of mixed microsphere bulk optodes of similar size, fabricated from the same chromoionophore without additional labeling. Sodium ionophore X, potassium ionophore III, and grafted AU-1 in poly(butyl acrylate) were the ionophores used in the bulk optode microsphere ion sensors for Na(+), K(+), and Ca(2+), respectively, in combination with the cation-exchanger NaTFPB (sodium tetrakis-[3,5-bis(trifluoromethyl)phenyl]borate) and the same concentration of the chromoionophore ETH 5294 (9-(di-ethylamino)-5-octadecanoylimino-5H-benzo[a]phen-oxazine) in plasticized poly(vinyl chloride). Excellent reproducibility was achieved for the sensing of potassium ions. The effect of sample pH was relatively small at near-physiological pH and followed theoretical predictions, yet the sample temperature was found to influence the sensor response to a larger extent. Multiplexed ion sensing was achieved by taking advantage of the chemical tunability of the sensor response, adjusting the sensor compositions so that the three types of ion sensors responded with distinct levels of protonation of the chromoionophore. Consequently, three well-resolved peaks were simultaneously observed in the single-channel histogram during the multiplexed calibration as well as in the subsequent measurement of the three cations in 10-fold-diluted sheep plasma. The assigned peak positions corresponded very well to the physiological range of the measured ions.

  17. Blood pressure interacts with APOE ε4 to predict memory performance in a midlife sample

    PubMed Central

    Oberlin, Lauren E.; Manuck, Stephen B.; Gianaros, Peter J.; Ferrell, Robert E.; Muldoon, Matthew F.; Jennings, J. Richard; Flory, Janine D.; Erickson, Kirk I.

    2015-01-01

    Objective Elevated blood pressure and the Apolipoprotein ε4 allele (APOE ε4) are independent risk factors for Alzheimer’s disease. We sought to determine whether the combined presence of the APOE ε4 allele and elevated blood pressure is associated with lower cognitive performance in cognitively healthy middle-aged adults. Methods A total of 975 participants aged 30–54 (mean age = 44.47) were genotyped for APOE. Cardiometabolic risk factors including blood pressure, lipids, and glucose were assessed and cognitive function was measured using the Trail Making Test and the Visual Reproduction and Logical Memory subtests from the Wechsler Memory Scale. Results Multivariable regression analysis showed that the association between APOE ε4 and episodic memory performance varied as a function of systolic blood pressure (SBP), such that elevated SBP was predictive of poorer episodic memory performance only in APOE ε4 carriers (β = −.092; t = −2.614; p = .009). Notably, this association was apparent at prehypertensive levels (≥ 130 mm Hg), even after adjusting for physical activity, depression, smoking, and other cardiometabolic risk factors. Conclusions The joint presence of APOE ε4 and elevated SBP, even at prehypertensive levels, is associated with lower cognitive performance in healthy, middle-aged adults. Results of this study suggest that the combination of APOE ε4 and elevated SBP may synergistically compromise memory function well before the appearance of clinically significant impairments. Interventions targeting blood pressure control in APOE ε4 carriers during midlife should be studied as a possible means to reduce the risk of cognitive decline in genetically susceptible samples. PMID:25730733

  18. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF.

    PubMed

    Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid

    2017-01-18

    Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P < 0.01). Using ≥1.700 plus top three results matching as the cut-off value, species level identifications were obtained from 100/144 (69%) samples using Saponin, 103/144 (72%) using SDS, and 106/144 (74%) using SepsiTyper and there was no statistical difference between the methods. No true discordances between culture and direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.

  19. Analytical Validation of Quantitative Real-Time PCR Methods for Quantification of Trypanosoma cruzi DNA in Blood Samples from Chagas Disease Patients

    PubMed Central

    Ramírez, Juan Carlos; Cura, Carolina Inés; Moreira, Otacilio da Cruz; Lages-Silva, Eliane; Juiz, Natalia; Velázquez, Elsa; Ramírez, Juan David; Alberti, Anahí; Pavia, Paula; Flores-Chávez, María Delmans; Muñoz-Calderón, Arturo; Pérez-Morales, Deyanira; Santalla, José; Guedes, Paulo Marcos da Matta; Peneau, Julie; Marcet, Paula; Padilla, Carlos; Cruz-Robles, David; Valencia, Edward; Crisante, Gladys Elena; Greif, Gonzalo; Zulantay, Inés; Costales, Jaime Alfredo; Alvarez-Martínez, Miriam; Martínez, Norma Edith; Villarroel, Rodrigo; Villarroel, Sandro; Sánchez, Zunilda; Bisio, Margarita; Parrado, Rudy; Galvão, Lúcia Maria da Cunha; da Câmara, Antonia Cláudia Jácome; Espinoza, Bertha; de Noya, Belkisyole Alarcón; Puerta, Concepción; Riarte, Adelina; Diosque, Patricio; Sosa-Estani, Sergio; Guhl, Felipe; Ribeiro, Isabela; Aznar, Christine; Britto, Constança; Yadón, Zaida Estela; Schijman, Alejandro G.

    2015-01-01

    An international study was performed by 26 experienced PCR laboratories from 14 countries to assess the performance of duplex quantitative real-time PCR (qPCR) strategies on the basis of TaqMan probes for detection and quantification of parasitic loads in peripheral blood samples from Chagas disease patients. Two methods were studied: Satellite DNA (SatDNA) qPCR and kinetoplastid DNA (kDNA) qPCR. Both methods included an internal amplification control. Reportable range, analytical sensitivity, limits of detection and quantification, and precision were estimated according to international guidelines. In addition, inclusivity and exclusivity were estimated with DNA from stocks representing the different Trypanosoma cruzi discrete typing units and Trypanosoma rangeli and Leishmania spp. Both methods were challenged against 156 blood samples provided by the participant laboratories, including samples from acute and chronic patients with varied clinical findings, infected by oral route or vectorial transmission. kDNA qPCR showed better analytical sensitivity than SatDNA qPCR with limits of detection of 0.23 and 0.70 parasite equivalents/mL, respectively. Analyses of clinical samples revealed a high concordance in terms of sensitivity and parasitic loads determined by both SatDNA and kDNA qPCRs. This effort is a major step toward international validation of qPCR methods for the quantification of T. cruzi DNA in human blood samples, aiming to provide an accurate surrogate biomarker for diagnosis and treatment monitoring for patients with Chagas disease. PMID:26320872

  20. Correlates of disclosure of sexual violence among Kenyan youth.

    PubMed

    Boudreau, Courtney L; Kress, Howard; Rochat, Roger W; Yount, Kathryn M

    2018-05-01

    Sexual violence (SV) against children is a global health and human rights issue that can have short and long-term consequences for health and wellbeing. Disclosing SV increases the likelihood that children can access health and protective services and receive psychosocial support. Research in high-income countries has found that child SV survivors are more likely to disclose when they are girls/women, experience fewer SV events, and experience SV perpetrated by a stranger. No studies have examined correlates of SV disclosure in Kenya. The objective of this research was to assess the correlates of disclosing SV among Kenyan youth ages 13-24 who reported an SV experience before age 18. In 2010, the Kenya Ministry of Gender, Children and Social Development, the U.S. Centers for Disease Control and Prevention's (CDC) Division of Violence Prevention, the UNICEF Kenya Country Office, and the Kenya National Bureau of Statistics (KNBS) conducted a national survey of violence against children. These data were used to conduct weighted logistic regression analyses to determine which factors were correlated with reporting SV disclosure. Among the 27.8% of girls/women and 14.5% of boys/men who reported SV before age 18, 44.6% of girls/women and 28.2% of boys/men reported to have disclosed the experience. In weighted logistic regression analysis, the odds of disclosure were lower among survivors who were boys/men and among survivors who reported more SV events, and higher when any perpetrator was a family member. More context-specific research on SV disclosure among young people is needed globally. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. INTERNAL ROOT MORPHOLOGY IN MANDIBULAR FIRST PERMANENT MOLARS IN A KENYAN POPULATION.

    PubMed

    Muriithi, N J; Maina, S W; Okoth, J; Gathece, L W

    2012-05-01

    To determine the internal root morphology and gender variations in mandibular first permanent molars in a Kenyan population. In vitro descriptive cross sectional study. School of Dental Sciences, University of Nairobi The mesial root of mandibular first molars had two canals in 96.3% of the teeth in both males and females and-type IV canal configuration was most prevalent in the mesial root. The distal root of the mandibular first molar had one canal in 57.7% of the teeth in males and females. There were significant gender variations in the number of canals and canal configurations in the distal root. Two canals were more prevalent in females (53.6%) compared to males (30.4%) and a single canal was more frequent in males (69.6%) compared to females (46.4%) (P=0.001). Canal types 1, 11 and IV were the most frequent in the mandibular distal root. The gender variation in the frequency of canal types I, II and IV in the distal root was statistically significant (P=0.001). Most of the mandibular first molars have three canals (56%). Two canals in the distal root are more frequent among females (53.6%) compared to males (30.4%).

  2. Glucagon blood test

    MedlinePlus

    ... type I - glucagon test; Hypoglycemia - glucagon test; Low blood sugar - glucagon test ... A blood sample is needed . ... When the needle is inserted to draw blood, some people feel ... Afterward, there may be some throbbing or a slight bruise. This ...

  3. Allogenic Blood Transfusion Following Total Hip Arthroplasty: Results from the Nationwide Inpatient Sample, 2000 to 2009

    PubMed Central

    Saleh, Anas; Small, Travis; Chandran Pillai, Aiswarya Lekshmi Pillai; Schiltz, Nicholas K.; Klika, Alison K.; Barsoum, Wael K.

    2014-01-01

    Background: The large-scale utilization of allogenic blood transfusion and its associated outcomes have been described in critically ill patients and those undergoing high-risk cardiac surgery but not in patients undergoing elective total hip arthroplasty. The objective of this study was to determine the trends in utilization and outcomes of allogenic blood transfusion in patients undergoing primary total hip arthroplasty in the United States from 2000 to 2009. Methods: An observational cohort of 2,087,423 patients who underwent primary total hip arthroplasty from 2000 to 2009 was identified in the Nationwide Inpatient Sample. International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes 99.03 and 99.04 were used to identify patients who received allogenic blood products during their hospital stay. Risk factors for allogenic transfusions were identified with use of multivariable logistic regression models. We used propensity score matching to estimate the adjusted association between transfusion and surgical outcomes. Results: The rate of allogenic blood transfusion increased from 11.8% in 2000 to 19.0% in 2009. Patient-related risk factors for receiving an allogenic blood transfusion include an older age, female sex, black race, and Medicaid insurance. Hospital-related risk factors include rural location, smaller size, and non-academic status. After adjusting for confounders, allogenic blood transfusion was associated with a longer hospital stay (0.58 ± 0.02 day; p < 0.001), increased costs ($1731 ± $49 [in 2009 U.S. dollars]; p < 0.001), increased rate of discharge to an inpatient facility (odds ratio, 1.28; 95% confidence interval, 1.26 to 1.31), and worse surgical and medical outcomes. In-hospital mortality was not affected by allogenic blood transfusion (odds ratio, 0.97; 95% confidence interval, 0.77 to 1.21). Conclusions: The increase in allogenic blood transfusion among total hip arthroplasty patients is concerning

  4. CEA blood test

    MedlinePlus

    Carcinoembryonic antigen blood test ... A blood sample is needed . ... When the needle is inserted to draw blood, some people feel moderate pain. Others feel only a prick or stinging. Afterward, there may be some throbbing or a slight bruise. This ...

  5. Learning from the nurses and the paramedics: the experience of a Kenyan medical officer intern-a call for research

    PubMed Central

    Mwenda, Aruyaru Stanley

    2012-01-01

    In the Kenyan medical educations system, one has to go through one year of internship after graduating from medical school in order to be licensed to practise medicine. This internship period is laden with work to the extent of overwhelming and stressing the medical officer interns. Irrespective of what competence interns come with into the field there is still a lot they have to learn from the nurses and the paramedics. Most of the learning takes place during the acute care settings when the intern is on call and is from the nurses. The paramedics most helpful to the intern are the theater assistants who teach interns how to use the various surgical instruments and sometimes direct during minor operations. PMID:22891094

  6. Prevalence of xenobiotic substances in first-trimester blood samples from Danish pregnant women: a cross-sectional study.

    PubMed

    Aagaard, Sissel Kramer; Larsen, Agnete; Andreasen, Mette Findal; Lesnikova, Iana; Telving, Rasmus; Vestergaard, Anna Louise; Tørring, Niels; Uldbjerg, Niels; Bor, Pinar

    2018-03-03

    The aim of this study was to investigate the prevalence of xenobiotic substances, such as caffeine, nicotine and illicit drugs (eg, cannabis and cocaine), in blood samples from first-trimester Danish pregnant women unaware of the screening. A cross - sectional study examined 436 anonymised residual blood samples obtained during 2014 as part of the nationwide prenatal first-trimester screening programme. The samples were analysed by ultra performance liquid chromatography with high-resolution time-of-flight mass spectrometry. An antenatal clinic in a Danish city with 62 000 inhabitants, where >95% of pregnant women joined the screening programme. The prevalence and patterns of caffeine, nicotine, medication and illicit drug intake during the first trimester of pregnancy. The prevalence of prescription and over-the-counter drug detection was 17.9%, including acetaminophen (8.9%) and antidepressants (3.0%), of which citalopram (0.9%) was the most frequent. The prevalence of illegal drugs, indicators of smoking (nicotine/cotinine) and caffeine was 0.9%, 9.9%, and 76.4%, respectively. Only 17.4% of women had no substance identified in their sample. This study emphasises the need for further translational studies investigating lifestyle habits during pregnancy, as well as the underlying molecular mechanisms through which xenobiotic substances may affect placental function and fetal development. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Evaluation of sample hemolysis in blood collected by S-Monovette using vacuum or aspiration mode.

    PubMed

    Lippi, Giuseppe; Avanzini, Paola; Musa, Roberta; Sandei, Franca; Aloe, Rosalia; Cervellin, Gianfranco

    2013-01-01

    In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the "vacuum" or "aspiration" mode. The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC. In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error. Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.

  8. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HUMAN BIOLOGICAL MARKERS:BLOOD AND URINE SAMPLE COLLECTION AND ANALYSES (EOHSI-AP-209-040)

    EPA Science Inventory

    This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...

  9. Rapid determination of amino acids in neonatal blood samples based on derivatization with isobutyl chloroformate followed by solid-phase microextraction and gas chromatography/mass spectrometry.

    PubMed

    Deng, Chunhui; Li, Ning; Zhang, Xiangmin

    2004-01-01

    The purpose of this study was to develop a simple, rapid and sensitive analytical method for determination of amino acids in neonatal blood samples. The developed method involves the employment of derivatization and a solid-phase microextraction (SPME) technique together with gas chromatography/mass spectrometry (GC/MS). Amino acids in blood samples were derivatized by a mixture of isobutyl chloroformate, methanol and pyridine, and the N(O,S)-alkoxycarbonyl alkyl esters thus formed were headspace extracted by a SPME fiber. Finally, the extracted analytes on the fiber were desorbed and detected by GC/MS in electron impact (EI) mode. L-Valine, L-leucine, L-isoleucine, L-phenylanaline and L-tyrosine in blood samples were quantitatively analyzed by measurement of the corresponding N(O,S)-alkoxycarbonyl alkyl esters using an external standard method. SPME conditions were optimized, and the method was validated. The method was applied to diagnosis of neonatal phenylkenuria (PKU) and maple syrup urine disease (MSUD) by the analyses of five amino acids in blood samples. The results showed that the proposed method is a potentially powerful tool for simultaneous screening for neonatal PKU and MSUD. Copyright (c) 2004 John Wiley & Sons, Ltd.

  10. Analytical sensitivity and specificity of a loop-mediated isothermal amplification (LAMP) kit prototype for detection of Trypanosoma cruzi DNA in human blood samples.

    PubMed

    Besuschio, Susana A; Llano Murcia, Mónica; Benatar, Alejandro F; Monnerat, Severine; Cruz, Israel; Picado, Albert; Curto, María de Los Ángeles; Kubota, Yutaka; Wehrendt, Diana P; Pavia, Paula; Mori, Yasuyoshi; Puerta, Concepción; Ndung'u, Joseph M; Schijman, Alejandro G

    2017-07-01

    This study aimed to assess analytical parameters of a prototype LAMP kit that was designed for detection of Trypanosoma cruzi DNA in human blood. The prototype is based on the amplification of the highly repetitive satellite sequence of T.cruzi in microtubes containing dried reagents on the inside of the caps. The reaction is carried out at 65°C during 40 minutes. Calcein allows direct detection of amplified products with the naked eye. Inclusivity and selectivity were tested in purified DNA from Trypanosoma cruzi stocks belonging to the six discrete typing units (DTUs), in DNA from other protozoan parasites and in human DNA. Analytical sensitivity was estimated in serial dilutions of DNA samples from Sylvio X10 (Tc I) and CL Brener (Tc VI) stocks, as well as from EDTA-treated or heparinized blood samples spiked with known amounts of cultured epimastigotes (CL Brener). LAMP sensitivity was compared after DNA extraction using commercial fiberglass columns or after "Boil & Spin" rapid preparation. Moreover, the same DNA and EDTA-blood spiked samples were subjected to standardized qPCR based on the satellite DNA sequence for comparative purposes. A panel of peripheral blood specimens belonging to Chagas disease patients, including acute, congenital, chronic and reactivated cases (N = 23), as well as seronegative controls (N = 10) were evaluated by LAMP in comparison to qPCR. LAMP was able to amplify DNAs from T. cruzi stocks representative of the six DTUs, whereas it did not amplify DNAs from Leishmania sp, T. brucei sp, T. rangeli KPN+ and KPN-, P. falciparum and non-infected human DNA. Analytical sensitivity was 1x10-2 fg/μL of both CL Brener and Sylvio X10 DNAs, whereas qPCR detected up to 1x 10-1 fg/μL of CL Brener DNA and 1 fg/μl of Sylvio X10 DNA. LAMP detected 1x10-2 parasite equivalents/mL in spiked EDTA blood and 1x10-1 par.eq/mL in spiked heparinized blood using fiberglass columns for DNA extraction, whereas qPCR detected 1x10-2 par.eq./mL in EDTA blood

  11. Comparison of the image-derived radioactivity and blood-sample radioactivity for estimating the clinical indicators of the efficacy of boron neutron capture therapy (BNCT): 4-borono-2-18F-fluoro-phenylalanine (FBPA) PET study.

    PubMed

    Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun

    2016-12-01

    In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p < 0.001). Image-derived radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left

  12. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    PubMed

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  13. Assessing the performance of multiplexed tandem PCR for the diagnosis of pathogenic genotypes of Theileria orientalis using pooled blood samples from cattle.

    PubMed

    Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul

    2017-02-01

    Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost

  14. Glycosyltransferases as marker genes for the quantitative polymerase chain reaction-based detection of circulating tumour cells from blood samples of patients with breast cancer undergoing adjuvant therapy.

    PubMed

    Kölbl, Alexandra C; Hiller, Roman A; Ilmer, Mathias; Liesche, Friederike; Heublein, Sabine; Schröder, Lennard; Hutter, Stefan; Friese, Klaus; Jeschke, Udo; Andergassen, Ulrich

    2015-08-01

    Altered glycosylation is a predominant feature of tumour cells; it serves for cell adhesion and detachment, respectively, and facilitates the immune escape of these cells. Therefore changes in the expression of glycosyltransferase genes could help to identify circulating tumour cells (CTCs) in the blood samples of cancer patients using a quantitative polymerase chain reaction (PCR) approach. Blood samples of healthy donors were inoculated with certain numbers of established breast cancer cell line cells, thus creating a model system. These samples were analysed by quantitative PCR for the expression of six different glycosyltransferase genes. The three genes with the best results in the model system were consecutively applied to samples from adjuvant breast cancer patients and of healthy donors. FUT3 and GALNT6 showed the highest increase in relative expression, while GALNT6 and ST3GAL3 were the first to reach statistically significant different ∆CT-values comparing the sample with and without addition of tumour cells. These three genes were applied to patient samples, but did not show any significant results that may suggest the presence of CTCs in the blood. Although the relative expression of some of the glycosyltransferase genes exhibited reasonable results in the model system, their application to breast cancer patient samples will have to be further improved, e.g. by co-analysis of patient blood samples by gold-standard methods.

  15. Kenyan women adult literacy learners: why their motivation is difficult to sustain.

    PubMed

    Mwiria, K

    1993-05-01

    Kenya, like other Third World countries, has illiteracy rates for women which are twice those of men (in 1978, 35% of males and 70% of females aged 15 and above were illiterate). Since the beginning of the country's literacy campaign in 1979, women have comprised more than 70% of attendees. While this situation remains the case, the overall enrolment figures for the program have shown a gradual decline from 1979 to 1990 due to a lack of emphasis on individual motivation. Women dominate the literacy programs for several reasons: 1) women historically had less access to formal education than men; 2) the changing economy has forced women to assume extra responsibilities outside the home which make the women want to acquire formal skills; 3) women's schedules are often flexible enough to allow them to attend classes; 4) literacy classes provide women with needed socialization opportunities; and 5) in some communities cultural norms prevent men from attending classes with women. Women also have many obstacles which make their desire to become adult learners difficult to sustain. They have responsibilities which range from child-bearing to management of their family farms which leave them little time for study or class attendance. There is also little encouragement offered the women either at home or in their classes. At home they are confronted with a myriad of demands on their time. Their classes take place in conditions which are not very conducive to learning (classrooms designed for children or open air centers). The literacy teachers are, for the most part, unqualified. They must meet only minimal requirements and receive no training. The women also have less opportunities to practice their new skills outside of the classroom. Women have less time then men to read, and they are less fluent then men in English and Kiswahili, the 2 official languages of Kenya. Because Kenyan society is male-dominated, there is little encouragement given to women who attempt to

  16. Application of dried blood spot cards to determine olive oil phenols (hydroxytyrosol metabolites) in human blood.

    PubMed

    de Las Hazas, María Carmen López; Motilva, Maria José; Piñol, Carme; Macià, Alba

    2016-10-01

    In this study, a fast and simple blood sampling and sample pre-treatment method based on the use of the dried blood spot (DBS) cards and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) for the quantification of olive oil phenolic metabolites in human blood was developed and validated. After validation, the method was applied to determine hydroxytyrosol metabolites in human blood samples after the acute intake of an olive oil phenolic extract. Using the FTA DMPK-A DBS card under optimum conditions, with 20µL as the blood solution volume, 100µL of methanol/Milli-Q water (50/50, v/v) as the extraction solvent and 7 disks punched out from the card, the main hydroxytyrosol metabolites (hydroxytyrosol-3-O-sulphate and hydroxytyrosol acetate sulphate) were identified and quantified. The developed methodology allowed detecting and quantifying the generated metabolites at low μM levels. The proposed method is a significant improvement over existing methods to determine phenolic metabolites circulating in blood and plasma samples, thus making blood sampling possible with the volunteer pricking their own finger, and the subsequent storage of the blood in the DBS cards prior to chromatographic analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Kinetic quantitation of cerebral PET-FDG studies without concurrent blood sampling: statistical recovery of the arterial input function.

    PubMed

    O'Sullivan, F; Kirrane, J; Muzi, M; O'Sullivan, J N; Spence, A M; Mankoff, D A; Krohn, K A

    2010-03-01

    Kinetic quantitation of dynamic positron emission tomography (PET) studies via compartmental modeling usually requires the time-course of the radio-tracer concentration in the arterial blood as an arterial input function (AIF). For human and animal imaging applications, significant practical difficulties are associated with direct arterial sampling and as a result there is substantial interest in alternative methods that require no blood sampling at the time of the study. A fixed population template input function derived from prior experience with directly sampled arterial curves is one possibility. Image-based extraction, including requisite adjustment for spillover and recovery, is another approach. The present work considers a hybrid statistical approach based on a penalty formulation in which the information derived from a priori studies is combined in a Bayesian manner with information contained in the sampled image data in order to obtain an input function estimate. The absolute scaling of the input is achieved by an empirical calibration equation involving the injected dose together with the subject's weight, height and gender. The technique is illustrated in the context of (18)F -Fluorodeoxyglucose (FDG) PET studies in humans. A collection of 79 arterially sampled FDG blood curves are used as a basis for a priori characterization of input function variability, including scaling characteristics. Data from a series of 12 dynamic cerebral FDG PET studies in normal subjects are used to evaluate the performance of the penalty-based AIF estimation technique. The focus of evaluations is on quantitation of FDG kinetics over a set of 10 regional brain structures. As well as the new method, a fixed population template AIF and a direct AIF estimate based on segmentation are also considered. Kinetics analyses resulting from these three AIFs are compared with those resulting from radially sampled AIFs. The proposed penalty-based AIF extraction method is found to

  18. Impact of grey zone sample testing by enzyme-linked immunosorbent assay in enhancing blood safety: Experience at a tertiary care hospital in North India.

    PubMed

    Solanki, Archana; Singh, Abhay; Chaudhary, Rajendra

    2016-01-01

    Enzyme-linked immunosorbent assay (ELISA) used for screening blood donors for transfusion transmitted infections (TTIs) can sometimes fail to detect blood donors who are recently infected or possessing the low strength of pathogen. Estimation of a grey zone in ELISA testing and repeat testing of grey zone samples can further help in reducing the risks of TTI in countries where nucleic acid amplification testing for TTIs is not feasible. Grey zone samples with optical density (OD) lying between cut-off OD and 10% below the cut-off OD (cut-off OD × 0.9) were identified during routine ELISA testing. On performing repeat ELISA testing on grey zone samples in duplicate, the samples showing both OD value below grey zone were marked nonreactive, and samples showing one or both OD value in the grey zone were marked indeterminate. The samples on repeat testing showing one or both OD above cut-off value were marked positive. About 119 samples (77 for hepatitis B virus [HBV], 23 for human immunodeficiency virus [HIV], and 19 for hepatitis C virus [HCV]) were found to be in grey zone. On repeat testing of these samples in duplicate, 70 (58.8%) samples (45 for HBV, 12 for HIV, and 13 for HCV) were found to be reactive. Six (5%) samples (four for HBV, one for HIV, and one for HCV) were found to be indeterminate. Seventy donors initially screened negative, were found out to be potentially infectious on repeat grey zone testing. Thus, estimation of grey zone samples with repeat testing can further enhance the safety of blood transfusion.

  19. Picric acid capped silver nanoparticles as a probe for colorimetric sensing of creatinine in human blood and cerebrospinal fluid samples.

    PubMed

    Parmar, Ankita K; Valand, Nikunj N; Solanki, Kalpesh B; Menon, Shobhana K

    2016-02-21

    Creatinine is the most important parameter to be determined in the diagnosis of renal, muscular and thyroid function. The most common method for the determination of creatinine is Jaffe's reaction, a routine practice for blood and urine analysis. However, in cases of icteric and haemolyzed blood samples, interference occurs during the estimation of creatinine by other constituents present in the blood like bilirubin, creatine, and urea, which lead to wrong diagnosis. To overcome such difficulty, we have developed a silver nanoparticle (Ag NPs) based sensor for the selective determination of creatinine. In this study, a new approach has been given to the traditional Jaffe's reaction, by coating Ag NPs with picric acid (PA) to form an assembly that can selectively detect creatinine. The Ag NPs based sensor proficiently and selectively recognizes creatinine due to the ability of picric acid to bind with it and form a complex. The nanoassembly and the interactions were investigated by transmission electron microscopy (TEM), dynamic light scattering (DLS) analysis, UV-Vis spectroscopy, FT-IR spectroscopy and ESI-MS, which demonstrated the binding affinity of creatinine with PA-capped Ag NPs. A linear correlation was obtained in the range of 0.01 μM-1 μM with an R(2) value of 0.9998 and a lower detection limit of 8.4 nM. The sensor was successfully applied to different types of blood and CSF samples for the determination of creatinine, and the results were compared to that of the Jaffe's method. With the advantages of high sensitivity, selectivity and low sample volume, this method is potentially suitable for the on-site monitoring of creatinine.

  20. Chromatographic measurements of hemoglobin A2 in blood samples that contain sickle hemoglobin.

    PubMed

    Shokrani, M; Terrell, F; Turner, E A; Aguinaga, M D

    2000-04-01

    In the sickle cell syndromes, Hb A2 measurements aid in the differential diagnosis of sickle cell anemia from sickle-beta-thalassemia. The purpose of this study is to assess the Hb A2 levels in samples containing sickle hemoglobin (Hb S) by the use of an automated high performance liquid chromatography system (HPLC-Variant beta-thalassemia Short Program). The blood samples analyzed were from individuals of African descent living in the state of Tennessee who had either sickle cell trait (Hb AS), sickle cell disease (Hb SS), or sickle cell-hemoglobin C disease (Hb SC). Interestingly, the Hb A2 levels determined by HPLC were found elevated in samples containing Hb S. The Hb A2 mean in Hb AS samples (n=146) is 4.09% (SD +/- 0.42, range 2.20 to 5.20%); in Hb SS samples (n=33) it is 3.90% (SD +/- 1.08, range 0.60 to 5.90%); and in Hb SC samples (n=27) it is 4.46% (SD +/- 0.70, range 2.30 to 5.91%). The Hb A2 mean by HPLC in normal individuals (Hb AA, n=70) is 2.57% (SD +/- 0.25, range 2.1 to 3.0%), and the Hb A2 range in beta-thalassemia carriers is 4 to 9%. Our results show that the Hb A2 levels in Hb S-containing samples partially overlap with those expected from beta-thalassemia carriers. The hemoglobinopathy laboratory should be aware of this apparent elevation in Hb A2 levels determined by HPLC in individuals carrying Hb S. Other factors, such as family history and clinical symptoms, should be taken into account before a diagnosis of sickle cell trait, sickle-beta-thalassemia, or sickle cell anemia is made.

  1. Parvovirus B19 infection transmitted by transfusion of red blood cells confirmed by molecular analysis of linked donor and recipient samples.

    PubMed

    Yu, Mei-Ying W; Alter, Harvey J; Virata-Theimer, Maria Luisa A; Geng, Yansheng; Ma, Li; Schechterly, Cathy A; Colvin, Camilla A; Luban, Naomi L C

    2010-08-01

    Extremely high viremic levels of parvovirus B19 (B19V) can be found in acutely infected, but asymptomatic donors. However, reports of transmission by single-donor blood components are rare. In this prospective study, paired donor-recipient samples were used to investigate the transfusion risk. Posttransfusion plasma or blood samples from recipients were tested for B19V DNA by polymerase chain reaction, generally at 4 and 8 weeks, and for anti-B19V immunoglobulin (Ig)G by enzyme immunoassay, at 12 and 24 weeks. To rule out infection unrelated to transfusion, pretransfusion samples and linked donor's samples for each B19V DNA-positive recipient were assayed for B19V DNA and anti-B19V IgG and IgM. To confirm transmission, sequencing and phylogenetic analysis were performed. A total of 14 of 869 (1.6%) recipients were B19V DNA positive, but only 1 of 869 (0.12%; 95% confidence interval, 0.0029%-0.6409%) was negative for B19V DNA and anti-B19V IgG before transfusion and seroconverted posttransfusion. This newly infected patient received 5 × 10(10) IU B19V DNA in one red blood cell (RBC) unit from an acutely infected anti-B19V-negative donor in addition to RBCs from three other donors that cumulatively contained 1320 IU of anti-B19V IgG. DNA sequencing and phylogenetic analysis showed that sequences from the linked donor and recipient were identical (Genotype 1), thus establishing transfusion transmission. The 0.12% transmission rate documented here, although low, could nonetheless result in hundreds or thousands of infections annually in the United States based on calculated confidence limits. Although most would be asymptomatic, some could have severe clinical outcomes, especially in neonates and those with immunocompromised or hemolytic states. © 2010 American Association of Blood Banks.

  2. Headspace gas chromatography-mass spectrometry analysis of isoflurane enantiomers in blood samples after anesthesia with the racemic mixture.

    PubMed

    Schmidt, R; Wahl, H G; Häberle, H; Dieterich, H J; Schurig, V

    1999-01-01

    Several in vivo and in vitro studies on the stereoselective potency of isoflurane enantiomers suggest beneficial effects of the (+)-(S)-enantiomer. In order to detect possible differences in the pharmacokinetics of isoflurane enantiomers, a clinical study of 41 patients undergoing general anesthesia maintained with racemic isoflurane was performed. The isoflurane enantiomers were analyzed in blood samples drawn before induction, at cessation (day 0), and up to eight days after isoflurane anesthesia (day 1-8). A multipurpose sampler (Gerstel MPS) was used for the headspace gas chromatography-mass spectrometry (GC/MS) analysis, and it was combined with a cold injection system (Gerstel CIS 3) for coldtrapping, enrichment, and focusing of the analyte. The enantiomer separation was achieved by using a capillary column coated with octakis(3-O-butanoyl-2,6-di-O-pentyl)-gamma-cyclodextrin (Lipodex E) dissolved in the polysiloxane PS 255. Detection was done in the selected ion monitoring mode with ions m/z 117 and m/z 149. An enrichment of (+)-(S)-isoflurane in all blood samples drawn after anesthesia was found. The highest enantiomer bias, up to 52-54% (+)-(S)-isoflurane as compared to 50% for the racemate, was observed on day 2 for most of the patients. Furthermore, quantification of isoflurane in blood samples of five patients was done by enantiomer labeling, employing enantiomerically pure (+)-(S)-isoflurane as internal standard. The isoflurane concentration decreased rapidly from 383 nmol/ml to 0.6 nmol/ml (mean values) eight days after anesthesia. The present study shows differences in the pharmacokinetics of isoflurane enantiomers in man. However, it is not possible to distinguish between enantioselective distribution and enantioselective metabolism, if any.

  3. Order of draw practices in venous blood sampling at clinical biochemistry departments in the Danish health care system.

    PubMed

    Jacobsen, Katja Kemp; Brandt, Ida; Christensen, Anne Vindahl; Rimsø, Bjørk Anine; Krøier, Camilla Julie; Sørensen, Michelle; Smith, Julie; Jensen, Kathrine Overgaard Foss; Larsen, Jeppe Madura

    2018-06-01

    Deviation in blood collection procedures is a central source of preanalytical variation affecting overall analytical and diagnostic precision. The order of draw of venous sampling is suspected to affect analytical results, in particular for coagulation analysis. Here we compare the procedures in venous blood sampling among clinical biochemistry departments to assess the uniformity of order of blood draw and adherence to international guidelines in the Danish health care system. We collected venous order of draw procedures from 49 clinical biochemistry departments at 22 public hospitals in Denmark. Procedures were compared to the international guidelines fromthe Clinical Laboratory Standards Institute (CLSI) and World Health Organization (WHO), and assessed in relation to department ISO 15189:2012 accreditation. We observed seven different order of draw procedures related to citrate, serum, heparin, and EDTA tubes, and the use of discard tubes in relation to coagulation assays. 31 departments (63.3%) were found to adhere to CLSI and WHO guidelines. A majority of departments instructs the use of discard tubes before collection for coagulation assays in citrate tubes (44 departments; 89.8%). The citrate tube was the first sample tube to be drawn for most departments (35 departments; 75.5%); and the preferred order of non-citrate tubes was serum-heparin-EDTA (36 departments; 73.5%). Adherence to the CLSI and WHO guidelines was not associated with department ISO 15189:2012 accreditation (p = .57). Venous order of draw procedures is diverse at Danish clinical biochemistry departments and show moderate adherence to international guidelines. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. [Determination of Al, Be, Cd, Co, Cr, Mn, Ni, Pb, Se and Tl in whole blood by atomic absorption spectrometry without preliminary sample digestion].

    PubMed

    Ivanenko, N B; Ivanenko, A A; Solov'ev, N D; Navolotskiĭ, D V; Pavlova, O V; Ganeev, A A

    2014-01-01

    Methods of whole blood trace element determination by Graphite furnace atomic absorption spectrometry (in the variant of Zeeman's modulation polarization spectrometry) have been proposed. They do not require preliminary sample digestion. Furnace programs, modifiers and blood dilution factors were optimized. Seronorm™ human whole blood reference materials were used for validation. Dynamic ranges (for undiluted blood samples) were: Al 8 ¸ 210 мg/L; Be 0.3 ¸ 50 мg/L; Cd 0.2 ¸ 75 мg/L; Сo 5 ¸ 350 мg/L; Cr 10 ¸ 100 мg/L; Mn 6 ¸ 250 мg/L; Ni 10 ¸ 350 мg/L; Pb 3 ¸ 240 мg/L; Se 10 ¸ 500 мg/L; Tl 2 ¸ 600 мg/L. Precision (RSD) for the middle of dynamic range ranged from 5% for Mn to 11 for Se.

  5. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less

  6. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    DOE PAGES

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    2016-04-07

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less

  7. A Qualitative Evaluation of Hand Drying Practices among Kenyans

    PubMed Central

    Person, Bobbie; Schilling, Katharine; Owuor, Mercy; Ogange, Lorraine; Quick, Rob

    2013-01-01

    Background Recommended disease prevention behaviors of hand washing, hygienic hand drying, and covering one’s mouth and nose in a hygienic manner when coughing and sneezing appear to be simple behaviors but continue to be a challenge to successfully promote and sustain worldwide. We conducted a qualitative inquiry to better understand current hand drying behaviors associated with activities of daily living, and mouth and nose covering practices, among Kenyans. Methods and Findings We conducted 7 focus group discussions; 30 in-depth interviews; 10 structured household observations; and 75 structured observations in public venues in the urban area of Kisumu; rural communities surrounding Kisumu; and a peri-urban area outside Nairobi, Kenya. Using a grounded theory approach, we transcribed and coded the narrative data followed by thematic analysis of the emergent themes. Hand drying, specifically on a clean towel, was not a common practice among our participants. Most women dried their hands on their waist cloth, called a leso, or their clothes whether they were cooking, eating or cleaning the nose of a young child. If men dried their hands, they used their trousers or a handkerchief. Children rarely dried their hands; they usually just wiped them on their clothes, shook them, or left them wet as they continued with their activities. Many people sneezed into their hands and wiped them on their clothes. Men and women used a handkerchief fairly often when they had a runny nose, cold, or the flu. Most people coughed into the air or their hand. Conclusions Drying hands on dirty clothes, rags and lesos can compromise the benefits of handwashing. Coughing and sneezing in to an open hand can contribute to spread of disease as well. Understanding these practices can inform health promotion activities and campaigns for the prevention and control of diarrheal disease and influenza. PMID:24069302

  8. A qualitative evaluation of hand drying practices among Kenyans.

    PubMed

    Person, Bobbie; Schilling, Katharine; Owuor, Mercy; Ogange, Lorraine; Quick, Rob

    2013-01-01

    Recommended disease prevention behaviors of hand washing, hygienic hand drying, and covering one's mouth and nose in a hygienic manner when coughing and sneezing appear to be simple behaviors but continue to be a challenge to successfully promote and sustain worldwide. We conducted a qualitative inquiry to better understand current hand drying behaviors associated with activities of daily living, and mouth and nose covering practices, among Kenyans. We conducted 7 focus group discussions; 30 in-depth interviews; 10 structured household observations; and 75 structured observations in public venues in the urban area of Kisumu; rural communities surrounding Kisumu; and a peri-urban area outside Nairobi, Kenya. Using a grounded theory approach, we transcribed and coded the narrative data followed by thematic analysis of the emergent themes. Hand drying, specifically on a clean towel, was not a common practice among our participants. Most women dried their hands on their waist cloth, called a leso, or their clothes whether they were cooking, eating or cleaning the nose of a young child. If men dried their hands, they used their trousers or a handkerchief. Children rarely dried their hands; they usually just wiped them on their clothes, shook them, or left them wet as they continued with their activities. Many people sneezed into their hands and wiped them on their clothes. Men and women used a handkerchief fairly often when they had a runny nose, cold, or the flu. Most people coughed into the air or their hand. Drying hands on dirty clothes, rags and lesos can compromise the benefits of handwashing. Coughing and sneezing in to an open hand can contribute to spread of disease as well. Understanding these practices can inform health promotion activities and campaigns for the prevention and control of diarrheal disease and influenza.

  9. Range of therapeutic metformin concentrations in clinical blood samples and comparison to a forensic case with death due to lactic acidosis.

    PubMed

    Hess, C; Unger, M; Madea, B; Stratmann, B; Tschoepe, D

    2018-05-01

    Due to a lack of reference values for blood concentration of metformin in the literature, the forensic evaluation of metformin findings in blood samples is difficult. Interpretations with regard to the assessment of blood concentrations as well as an estimation of the ingested metformin amounts are often vague. Furthermore, post mortem evaluation of death due to lactic acidosis because of metformin is difficult since renal performance or lactate concentrations can not always reliably be determined after death. To describe a concentration range in clinical samples after chronic use of metformin, metformin serum concentrations were determined in serum samples of 95 diabetic patients receiving daily doses of 500mg-3000mg of metformin. The analyses of metformin was carried out using a validated high performance liquid chromatograph coupled to triple quadrupole mass spectrometry (LC-QQQ-MS). On average, metformin concentrations were 1846ng/mL (blood concentration, lactate concentration and glomerular filtration rate in post mortem cases of lactic acidosis due to metformin intoxication are discussed. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Point-of-care blood gases, electrolytes, chemistries, hemoglobin, and hematocrit measurement in venous samples from pet rabbits.

    PubMed

    Selleri, Paolo; Di Girolamo, Nicola

    2014-01-01

    Point-of-care testing is an attractive option in rabbit medicine, because it permits rapid analysis of a panel of electrolytes, chemistries, blood gases, hemoglobin, and hematocrit, requiring only 65 μL of blood. The purpose of this study was to evaluate the performance of a portable clinical analyzer for measurement of pH, partial pressure of CO2, Na, chloride, potassium, blood urea nitrogen, glucose, hematocrit, and hemoglobin in healthy and diseased rabbits. Blood samples obtained from 30 pet rabbits were analyzed immediately after collection by the portable clinical analyzer (PCA) and immediately thereafter (time <20 sec) by a reference analyzer. Bland-Altman plots and Passing-Bablok regression analysis were used to compare the results. Limits of agreement were wide for all the variables studied, with the exception of pH. Most variables presented significant proportional and/or constant bias. The current study provides sufficient evidence that the PCA presents reliability for pH, although its low agreement with a reference analyzer for the other variables does not support their interchangeability. Limits of agreement provided for each variable allow researchers to evaluate if the PCA is reliable enough for their scope. To the authors' knowledge, the present is the first report evaluating a PCA in the rabbit.

  11. Detection of human parvovirus 4 viremia in the follow-up blood samples from seropositive individuals suggests the existence of persistent viral replication or reactivation of latent viral infection.

    PubMed

    Chen, Mao-Yuan; Hung, Chien-Ching; Lee, Kuang-Lun

    2015-06-19

    The transmission routes for human parvovirus 4 (PARV4) infections in areas with high seroprevalence are not known. In the work described here, persistent PARV4 viral replication was investigated by conducting a longitudinal study. Ten healthcare workers each provided a blood sample at the beginning of the study (first sample) and 12 months later (second sample). The paired samples were tested for PARV4-positivity by immunoblotting analysis and nested polymerase chain reactions. IgG antibodies against PARV4 were detected in six participants, three of whom also had IgM antibodies against PARV4. The immunoblotting results did not vary over time. PARV4 DNA was detected in the first blood sample from one participant who had IgG antibodies against PARV4 and in the second blood samples from 2 participants who had IgG and IgM antibodies against PARV4. Detection of PARV4 DNA in the second blood samples from two seropositive participants suggests the existence of persistent PARV4 replication or reactivation of inactive virus in the tissues. The finding of persistent or intermittent PARV4 replication in individuals with past infections provides an important clue toward unraveling the non-parenteral transmission routes of PARV4 infection in areas where the virus is endemic.

  12. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17550 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  13. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17547 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  14. Analytical sensitivity and specificity of a loop-mediated isothermal amplification (LAMP) kit prototype for detection of Trypanosoma cruzi DNA in human blood samples

    PubMed Central

    Besuschio, Susana A.; Llano Murcia, Mónica; Benatar, Alejandro F.; Monnerat, Severine; Cruz, Israel; Picado, Albert; Curto, María de los Ángeles; Kubota, Yutaka; Wehrendt, Diana P.; Pavia, Paula; Mori, Yasuyoshi; Puerta, Concepción; Ndung'u, Joseph M.

    2017-01-01

    This study aimed to assess analytical parameters of a prototype LAMP kit that was designed for detection of Trypanosoma cruzi DNA in human blood. The prototype is based on the amplification of the highly repetitive satellite sequence of T.cruzi in microtubes containing dried reagents on the inside of the caps. The reaction is carried out at 65°C during 40 minutes. Calcein allows direct detection of amplified products with the naked eye. Inclusivity and selectivity were tested in purified DNA from Trypanosoma cruzi stocks belonging to the six discrete typing units (DTUs), in DNA from other protozoan parasites and in human DNA. Analytical sensitivity was estimated in serial dilutions of DNA samples from Sylvio X10 (Tc I) and CL Brener (Tc VI) stocks, as well as from EDTA-treated or heparinized blood samples spiked with known amounts of cultured epimastigotes (CL Brener). LAMP sensitivity was compared after DNA extraction using commercial fiberglass columns or after “Boil & Spin” rapid preparation. Moreover, the same DNA and EDTA-blood spiked samples were subjected to standardized qPCR based on the satellite DNA sequence for comparative purposes. A panel of peripheral blood specimens belonging to Chagas disease patients, including acute, congenital, chronic and reactivated cases (N = 23), as well as seronegative controls (N = 10) were evaluated by LAMP in comparison to qPCR. LAMP was able to amplify DNAs from T. cruzi stocks representative of the six DTUs, whereas it did not amplify DNAs from Leishmania sp, T. brucei sp, T. rangeli KPN+ and KPN-, P. falciparum and non-infected human DNA. Analytical sensitivity was 1x10-2 fg/μL of both CL Brener and Sylvio X10 DNAs, whereas qPCR detected up to 1x 10−1 fg/μL of CL Brener DNA and 1 fg/μl of Sylvio X10 DNA. LAMP detected 1x10-2 parasite equivalents/mL in spiked EDTA blood and 1x10-1 par.eq/mL in spiked heparinized blood using fiberglass columns for DNA extraction, whereas qPCR detected 1x10-2 par.eq./mL in EDTA

  15. Polybrominated diphenyl ethers (PBDEs) levels in blood samples from children living in the metropolitan area of Guadalajara, Jalisco, Mexico.

    PubMed

    Orta-García, Sandra T; Ochoa-Martínez, Ángeles C; Varela-Silva, José A; Pérez-Maldonado, Iván N

    2018-02-01

    The aim of this study was to perform a polybrominated diphenyl ethers (PBDEs) exposure assessment using blood samples collected from children living in the metropolitan area of Guadalajara, Jalisco, Mexico (GDL). Five congeners of PBDEs were analyzed using a gas chromatography/mass spectrometry technique. The blood concentrations of total PBDEs ranged from 5.50 to 169 ng/g lipid (42.0 ± 18.0 ng/g lipid; mean ± standard deviation). Regarding BDE congeners, the main congener (highest blood levels) was BDE99 (14.5 ± 5.50 ng/g lipid), followed by BDE100 (9.80 ± 3.40 ng/g lipid) and BDE154 (9.80 ± 5.90 ng/g lipid), and finally BDE153 (5.80 ± 2.30 ng/g lipid) and BDE47 (2.20 ± 1.20 ng/g lipid). In conclusion, blood PBDEs concentrations of concern were detected in this study, as blood levels were similar to the ones found in North America (the highest worldwide).

  16. [Detection of human parvovirus B19, human bocavirus and human parvovirus 4 infections in blood samples among 95 patients with liver disease in Nanjing by nested PCR].

    PubMed

    Tong, Rui; Zhou, Wei-Min; Liu, Xi-Jun; Wang, Yue; Lou, Yong-Liang; Tan, Wen-Jie

    2013-04-01

    To analyze the infection of human parvovirus B19, human bocavirus (HBoV) and human parvovirus 4 (PARV4) in blood samples among patients with liver disease in Nanjing by molecular detection. Nested PCR assays were designed and validated to detect B19, HBoV and PARV4, respectively. The assays were used to screen three parvoviruses in blood samples from 95 patients with different liver disease in Nanjing. The parvovirus infection was analyzed statistically. The detection limits were 10 copies of genomic DNA equivalents per reaction for each assays and the good specificity were observed. The frequency of B19 and HBoV were 2/95 (2.1%) and 9/95 (9.5%) in blood samples respectively. No PARV4 was detected. HBoV was detected in 3/5 patients with drug-induced hepatitis. Both B19 and HBoV infection were detected in blood from patients with liver disease.

  17. Absorption spectroscopy setup for determination of whole human blood and blood-derived materials spectral characteristics

    NASA Astrophysics Data System (ADS)

    Wróbel, M. S.; Gnyba, M.; Milewska, D.; Mitura, K.; Karpienko, K.

    2015-09-01

    A dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood samples, separated components: plasma, saline, washed erythrocytes in saline and human whole blood with biomarkers - biocompatible nanodiamonds (ND). Blood samples had been derived from a number of healthy donors. The results prove a correct setup arrangement, with adequate preprocessing of the data. The results of blood-ND mixtures measurements show no toxic effect on blood cells, which proves the NDs as a potential biocompatible biomarkers.

  18. Hepatitis C genotype distribution in patient and blood donor samples in South Africa for the period 2008-2012.

    PubMed

    Prabdial-Sing, N; Chirwa, T; Thaver, J; Smuts, H; Vermeulen, M; Suchard, M; Puren, A J

    2016-11-01

    There are limited molecular epidemiological studies of hepatitis C at a national level in South Africa. The introduction of newer treatment modalities for hepatitis C requires knowledge of the genotypes as these may have different prognostic and therapeutic implications. This retrospective study describes genotype distributions of patients attending specialist clinics and a blood donor group studied during the period 2008-2012 in South Africa. Residual samples from diagnostic viral load testing from specialist clinics in South Africa (n=941) and from the South African National Blood Service (n=294) were analysed quantitatively by real-time PCR and genotyped using the Versant line probe assay or sequencing. Genotype 1 was predominant in blood donors (34%), whilst genotype 5a was prevalent in patients (36%). In the blood donor group, genotype 4 was detected for the first time. Genotype 2 was rare in the patient group and not detected in blood donors. Genotype 1 was the predominant genotype in the younger age groups (less than 30 years), whereas genotype 5a was found at higher proportions in the older age groups for both the patient and blood donor groups, comprising more than 60% of genotypes in those older than 50 years. Genotypes 1 and 5 were at highest proportions across all provinces compared to other genotypes. In blood donors, genotype 1 was predominant among Caucasians (43%) and genotype 5a among Blacks (54%). Such information is required for planning the impact on the health sector with regard to newly emerging therapies for hepatitis C and burden of disease. © 2016 John Wiley & Sons Ltd.

  19. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    PubMed

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  20. The Blood Donation Ambivalence Survey: measuring conflicting attitudes about giving blood.

    PubMed

    Fox, K R; Himawan, L K; France, C R

    2017-05-18

    This study was designed to develop and conduct initial validation testing for a novel measure of ambivalence about donating blood. Previous studies of living organ, bone marrow and stem cell donors have identified donation-related ambivalence as a predictor of decisions about donation and post-donation outcomes. Ambivalence about blood donation has not received the same attention. In Study 1, a sample of young adults (N = 396) were administered test items of ambivalence, and exploratory (EFA) and confirmatory factor analyses (CFA) were performed to identify the Blood Donation Ambivalence Survey. In Study 2, a separate sample of young adults (N = 241) completed the Blood Donation Ambivalence Survey in addition to questionnaires assessing known predictors of blood donation. Exploratory and confirmatory factor analyses indicated a two-factor structure reflecting commitment to donating blood and indecision about giving blood. The commitment subscale was positively related to known predictors of increased donation behaviour (e.g. donation intention, self-efficacy), whereas the indecision subscale was positively related to known predictors of decreased donation behaviour (e.g. donation anxiety, negative affect). Furthermore, a history of blood donation was associated with greater commitment and less indecision. The present findings provide strong initial support for the reliability and validity of a novel measure of blood donor ambivalence. © 2017 British Blood Transfusion Society.