Sample records for keratoconus

  1. Genetics Home Reference: keratoconus

    MedlinePlus

    ... Health Conditions Genes Chromosomes & mtDNA Resources Help Me Understand Genetics Share: Email Facebook Twitter Home Health Conditions Keratoconus Keratoconus Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Keratoconus ...

  2. Keratoconus: an inflammatory disorder?

    PubMed Central

    Galvis, V; Sherwin, T; Tello, A; Merayo, J; Barrera, R; Acera, A

    2015-01-01

    Keratoconus has been classically defined as a progressive, non-inflammatory condition, which produces a thinning and steepening of the cornea. Its pathophysiological mechanisms have been investigated for a long time. Both genetic and environmental factors have been associated with the disease. Recent studies have shown a significant role of proteolytic enzymes, cytokines, and free radicals; therefore, although keratoconus does not meet all the classic criteria for an inflammatory disease, the lack of inflammation has been questioned. The majority of studies in the tears of patients with keratoconus have found increased levels of interleukin-6 (IL-6), tumor necrosis factor-α(TNF-α), and matrix metalloproteinase (MMP)-9. Eye rubbing, a proven risk factor for keratoconus, has been also shown recently to increase the tear levels of MMP-13, IL-6, and TNF-α. In the tear fluid of patients with ocular rosacea, IL-1α and MMP-9 have been reported to be significantly elevated, and cases of inferior corneal thinning, resembling keratoconus, have been reported. We performed a literature review of published biochemical changes in keratoconus that would support that this could be, at least in part, an inflammatory condition. PMID:25931166

  3. Keratoconus and Personality-A Review.

    PubMed

    Mannis, Mark J; Ling, Jennifer J; Kyrillos, Ralph; Barnett, Melissa

    2018-03-01

    To assess the existing literature on the subject of keratoconus and personality and to propose a theory that might account for the perceived personality changes associated with this condition. A literature search was conducted in the PubMed database using the term "keratoconus" in combination with keywords such as personality, psychiatry, psychology, anxiety, depression, or psychosis. A total of 15 articles pertaining to personality and psychiatric disorders in keratoconus were retained and reviewed. Although patients with keratoconus tend to score differently on personality scales compared with normal controls, the literature fails to substantiate the existence of a unique "keratoconic personality." Instead, patients with keratoconus prove to have more dysfunctional coping mechanisms that specifically alter their interaction with health care providers and may account for the persistent clinical impression of less respectful, conforming, and cooperative patients. We hypothesize that the stage of life at which keratoconus commonly presents plays a crucial role in personality and coping mechanism development that significantly affects behavioral patterns and the relationship with caregivers.

  4. The Auckland keratoconus study: identifying predictors of acute corneal hydrops in keratoconus.

    PubMed

    Fan Gaskin, Jennifer C; Good, William R; Jordan, Charlotte A; Patel, Dipika V; McGhee, Charles Nj

    2013-03-01

    The aim was to identify potential factors associated with acute corneal hydrops in a New Zealand population with keratoconus referred to a hospital eye service. In a single hospital centre, in a retrospective review, demographic and clinical features of subjects with keratoconus and corneal hydrops over a 17-year period were compared with an age- and gender-matched control group of subjects with keratoconus but no history of corneal hydrops. One hundred and one eyes of 101 subjects (mean age 24.6 ± 8.4 years) were identified with keratoconus-related corneal hydrops. Subjects were more likely to be of Pacific but less likely to be of New Zealand European ethnicity than control subjects (n = 101). In comparison, Maori ethnicity was not found to have a significantly positive or negative association with hydrops. The pre-hydrops visual acuity (VA) of affected eyes was poorer than that of controls (p < 0.001) at first presentation to our tertiary referral corneal and contact lens service. Hydrops typically developed approximately four years after diagnosis of keratoconus. Subjects with hydrops were more likely to have a history of eye-rubbing (p = 0.011) but less likely to have a family history of keratoconus (p = 0.05). In 31 cases, the acute hydrops event was their first optometric/ophthalmologic contact. There were no statistically significant differences in the prevalence of atopic disease, contact lens wear or overall corneal transplantation rate between the two groups. Pacific ethnicity, history of eye-rubbing, poor VA at first hospital presentation and lack of family history were statistically associated with developing acute corneal hydrops in keratoconus in a New Zealand population. Greater understanding of such predisposing risk factors may help develop early management strategies to delay or prevent progression of this disease. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  5. Evaluation of keratoconus progression.

    PubMed

    Shajari, Mehdi; Steinwender, Gernot; Herrmann, Kim; Kubiak, Kate Barbara; Pavlovic, Ivana; Plawetzki, Elena; Schmack, Ingo; Kohnen, Thomas

    2018-06-01

    To define variables for the evaluation of keratoconus progression and to determine cut-off values. In this retrospective cohort study (2010-2016), 265 eyes of 165 patients diagnosed with keratoconus underwent two Scheimpflug measurements (Pentacam) that took place 1 year apart ±3 months. Variables used for keratoconus detection were evaluated for progression and a correlation analysis was performed. By logistic regression analysis, a keratoconus progression index (KPI) was defined. Receiver-operating characteristic curve (ROC) analysis was performed and Youden Index calculated to determine cut-off values. Variables used for keratoconus detection showed a weak correlation with each other (eg, correlation r=0.245 between RPImin and Kmax, p<0.001). Therefore, we used parameters that took several variables into consideration (eg, D-index, index of surface variance, index for height asymmetry, KPI). KPI was defined by logistic regression and consisted of a Pachymin coefficient of -0.78 (p=0.001), a maximum elevation of back surface coefficient of 0.27 and coefficient of corneal curvature at the zone 3 mm away from the thinnest point on the posterior corneal surface of -12.44 (both p<0.001). The two variables with the highest Youden Index in the ROC analysis were D-index and KPI: D-index had a cut-off of 0.4175 (70.6% sensitivity) and Youden Index of 0.606. Cut-off for KPI was -0.78196 (84.7% sensitivity) and a Youden Index of 0.747; both 90% specificity. Keratoconus progression should be defined by evaluating parameters that consider several corneal changes; we suggest D-index and KPI to detect progression. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. [Correlations of telomere length changing and pathogeny of keratoconus].

    PubMed

    Wang, Jiao-jiao; Li, Shao-wei; Wang, Yi-qiang; Wang, Ye; Zhong, Wen-xian; Zang, Xin-jie

    2009-08-01

    To study telomere length, senescence-associated-beta-galactosidase (SA-beta-galactosidase) and senescence marker protein-30 (SMP-30) in the stromal cells of keratoconus or normal corneas respectively, aiming finding the association of these indexes with the phenotype of keratoconus. Experiment research. 37 keratoconus lesions corneas were removed from 32 keratoconus patients who were operated in Shangdong Eye Institute between January 2006 and December 2006, and 20 normal corneas were collected from eye bank. The keratoconus corneas ages were from 13 to 34 years [mean ages (19 + or - 5) years] and the control group consists of 20 normal corneas donor ages from 9 to 30 years [mean ages (19 + or - 4) years]. And there was no statistical difference of ages between keratoconus and normal corneas. Southern blot method was utilized to detect telomere length of genomic DNA. SA-beta-galactosidase was detected by 5-bromo-4-chloro-3-indolyl-beta-D-galactopyranoside (X-Gal) staining method respectively in keratoconus and normal corneas. Isolated mRNA from keratoconus and normal corneas were reverse-transcribed to cDNA and SMP-30 was detected using PCR with specific primers (sense: 5' ccg tgg atg cct ttg act at 3'; anti-sense: 5' caa ctt cat gc tgct ttg ga 3'). To compare normal corneas and keratoconus corneas by histopathological study. Statistical analysis by t test. The telomere length in stromal cells in keratoconus corneas were from 10.29 to 14.12 kb, mean (11.54 + or - 1.41) kb, while that of normal corneas were from 12.64 to 15.32 kb, mean (13.45 + or - 0.99) kb. The difference of telomere length in stromal cells of keratoconus and normal corneas reached a statistical significant level (t = 4.753, P < 0.05). That means the telomere length of keratoconus stroma was shorter than that of normal corneal stroma. Light microscopy revealed that collagen fibers in keratoconus corneal stroma were arranged in an irregular manner. Cells density in keratoconus stroma appeared lower

  7. Analysis of incidence of keratoconus in relatives of patients who underwent corneal transplant due to advanced keratoconus using the Orbscan II topographic graphs

    NASA Astrophysics Data System (ADS)

    López Olazagasti, Estela; Hernández y del Callejo, César E.; Ibarra-Galitzia, Jorge; Ramírez-Zavaleta, Gustavo; Tepichín, Eduardo

    2011-10-01

    Keratoconus is a corneal disease in which the cornea assumes a conical shape due to an irregular alteration of the internal structure of the corneal tissue and sometimes is progressive, especially in young people. Anatomically, the main signs of keratoconus are thinning of the cornea in its central or paracentral region, usually accompanied by an increase in this part of a high irregular astigmatism, with a consequent loss of vision. Its diagnosis requires a thorough study including the family history, a complete ophthalmologic examination and imaging studies. This diagnosis allows classifying the type of keratoconus, which allow determining options of management, with what it is possible to establish a visual prognosis of each eye. One of the indicators that help in the diagnosis of keratoconus is an inherited familiar propensity. The literature reports an incidence of keratoconus of 11%1 in first-degree relatives of patients with keratoconus. Results suggest an ethnic dependence, which implies that the knowledge of the tendency of keratoconus in the Mexican population is important. In this work, we present the preliminary results of the study realized to a group of relatives of patients who underwent corneal transplant by advanced keratoconus using Orbscan II topographic diagnosis, to determine the predisposition to Keratoconus in this group.e

  8. A new case of keratoconus associated with Williams-Beuren syndrome.

    PubMed

    Viana, Melissa Machado; Frasson, Maria; Leão, Letícia Lima; Stofanko, Martin; Gonçalves-Dornelas, Higgor; Cunha, Pricila da Silva; de Aguiar, Marcos José Burle

    2013-09-01

    Williams-Beuren syndrome is a multisystemic genetic disorder caused by a contiguous gene deletion at 7q11.23. Keratoconus is a complex disease and it is suspected to have a genetic origin, although the specific gene responsible for keratoconus has not been identified. Although there are several ocular features in Williams-Beuren syndrome, keratoconus is not regularly described as part of this syndrome. To report a new patient with keratoconus and Williams-Beuren syndrome. This is the third case of an association between Williams-Beuren syndrome and keratoconus. The authors believe that the Williams-Beuren syndrome chromosome region can be a possible target for further investigation as the genetic basis of keratoconus.

  9. SVM-based automatic diagnosis method for keratoconus

    NASA Astrophysics Data System (ADS)

    Gao, Yuhong; Wu, Qiang; Li, Jing; Sun, Jiande; Wan, Wenbo

    2017-06-01

    Keratoconus is a progressive cornea disease that can lead to serious myopia and astigmatism, or even to corneal transplantation, if it becomes worse. The early detection of keratoconus is extremely important to know and control its condition. In this paper, we propose an automatic diagnosis algorithm for keratoconus to discriminate the normal eyes and keratoconus ones. We select the parameters obtained by Oculyzer as the feature of cornea, which characterize the cornea both directly and indirectly. In our experiment, 289 normal cases and 128 keratoconus cases are divided into training and test sets respectively. Far better than other kernels, the linear kernel of SVM has sensitivity of 94.94% and specificity of 97.87% with all the parameters training in the model. In single parameter experiment of linear kernel, elevation with 92.03% sensitivity and 98.61% specificity and thickness with 97.28% sensitivity and 97.82% specificity showed their good classification abilities. Combining elevation and thickness of the cornea, the proposed method can reach 97.43% sensitivity and 99.19% specificity. The experiments demonstrate that the proposed automatic diagnosis method is feasible and reliable.

  10. Keratoconus: The ABCD Grading System.

    PubMed

    Belin, M W; Duncan, J K

    2016-06-01

    To propose a new keratoconus classification/staging system that utilises current tomographic data and better reflects the anatomical and functional changes seen in keratoconus. A previously published normative database was reanalysed to generate both anterior and posterior average radii of curvature (ARC and PRC) taken from a 3.0 mm optical zone centred on the thinnest point of the cornea. Mean and standard deviations were recorded and anterior data were compared to the existing Amsler-Krumeich (AK) Classification. ARC, PRC, thinnest pachymetry and distance visual acuity were then used to construct a keratoconus classification. 672 eyes of 336 patients were analysed. Anterior and posterior values were 7.65 ± 0.236 mm and 6.26 ± 0.214 mm, respectively, and thinnest pachymetry values were 534.2 ± 30.36 µm. The ARC values were 2.63, 5.47 and 6.44 standard deviations from the mean values of stages 1-3 in the AK classification, respectively. PRC staging uses the same standard deviation gates. The pachymetric values differed by 4.42 and 7.72 standard deviations for stages 2 and 3, respectively. A new keratoconus staging incorporates anterior and posterior curvature, thinnest pachymetric values, and distance visual acuity and consists of stages 0-4 (5 stages). The proposed system closely matches the existing AK classification stages 1-4 on anterior curvature. As it incorporates posterior curvature and thickness measurements based on the thinnest point, rather than apical measurements, the new staging system better reflects the anatomical changes seen in keratoconus. Georg Thieme Verlag KG Stuttgart · New York.

  11. Tear film inflammatory mediators in patients with keratoconus.

    PubMed

    Sorkhabi, Rana; Ghorbanihaghjo, Amir; Taheri, Nazli; Ahoor, Mohammad Hosein

    2015-08-01

    To determine the concentration of inflammatory mediators in the tear film of patients with keratoconus. Basal tears from patients with keratoconus and from normal controls were collected using a capillary tube. Patients with keratoconus were examined in a routine fashion, and keratometric readings were also taken from corneal topographic maps .The concentration of cytokines including Interleukin 6,10,1b and Interferon-γ was measured by enzyme-linked immunoadsorbent assay. Seventy-two subjects were enrolled in the study including 42 patients with keratoconus and 30 normals. Patients with keratoconus had significantly higher levels of Interlukin 6,1b and Interferon-γ (17.49 ± 1.92 pg/ml), (8.58 ± 1.15 pg/ml), and (33.33 ± 7.57 pg/ml) compared with control subjects (13.81 ± 1.71 pg/ml), (4.98 ± 0.52 pg/ml), and (22.99 ± 4.68 pg/ml), (P = 0.0001, P = 0.0001, and P = 0.0001). But the level of Interlukin-10 in keratoconus patients was significantly lower (6.07 ± 1.35 pg/ml) than controls (8.99 ± 0.70 pg/ml) (P = 0.0001). We realized that the proinflammatory markers (Interlukin-6,1-b and Interferon-γ) are over expressed, whereas the anti-inflammatory marker (Interlukin-10) is under expressed, indicating that the pathogenesis of keratoconus may involve complex chronic inflammatory events. Additional future studies will reveal the exact molecular and biochemical mechanisms that are required to better manage the disease and halt its progression.

  12. Topography and Higher Order Corneal Aberrations of the Fellow Eye in Unilateral Keratoconus.

    PubMed

    Aksoy, Sibel; Akkaya, Sezen; Özkurt, Yelda; Kurna, Sevda; Açıkalın, Banu; Şengör, Tomris

    2017-10-01

    Comparison of topography and corneal higher order aberrations (HOA) data of fellow normal eyes of unilateral keratoconus patients with keratoconus eyes and control group. The records of 196 patients with keratoconus were reviewed. Twenty patients were identified as unilateral keratoconus. The best corrected visual acuity (BCVA), topography and aberration data of the unilateral keratoconus patients' normal eyes were compared with their contralateral keratoconus eyes and with control group eyes. For statistical analysis, flat and steep keratometry values, average corneal power, cylindrical power, surface regularity index (SRI), surface asymmetry index (SAI), inferior-superior ratio (I-S), keratoconus prediction index, and elevation-depression power (EDP) and diameter (EDD) topography indices were selected. Mean age of the unilateral keratoconus patients was 26.05±4.73 years and that of the control group was 23.6±8.53 years (p>0.05). There was no statistical difference in BCVA between normal and control eyes (p=0.108), whereas BCVA values were significantly lower in eyes with keratoconus (p=0.001). Comparison of quantitative topographic indices between the groups showed that all indices except the I-S ratio were significantly higher in the normal group than in the control group (p<0.05). The most obvious differences were in the SRI, SAI, EDP, and EDD values. All topographic indices were higher in the keratoconus eyes compared to the normal fellow eyes. There was no difference between normal eyes and the control group in terms of spherical aberration, while coma, trefoil, irregular astigmatism, and total HOA values were higher in the normal eyes of unilateral keratoconus patients (p<0.05). All HOA values were higher in keratoconus eyes than in the control group. According to our study, SRI, SAI, EDP, EDD values, and HOA other than spherical aberration were higher in the clinically and topographically normal fellow eyes of unilateral keratoconus patients when compared

  13. Incidence and severity of keratoconus in Asir province, Saudi Arabia.

    PubMed

    Assiri, A A; Yousuf, B I; Quantock, A J; Murphy, P J

    2005-11-01

    To assess the incidence and associated signs and symptoms of patients with keratoconus in Asir Province, Saudi Arabia. 125 new keratoconus patients (51 male, 74 female; mean age 18.5 (SD 3.8) years; range 8--28 years) were recruited from referrals to the department of ophthalmology, Asir Central Hospital, over a 1 year period. Age, visual acuity, and keratometry were recorded along with clinical signs and symptoms. The incidence of keratoconus in Asir Province is 20 cases per 100,000 population. Also, the disease severity is high, as indicated by an early mean age (17.7 (3.6) years) with advanced stage keratoconus. Visual acuity, with either spectacles or rigid contact lenses, was 6/12 or better in 98% of eyes measured. Just over half (56%) of patients had atopic ocular disease. 16% of patients had a positive family history of the disease and 16% had atopic dermatitis (eczema and/or vitiligo). The incidence and severity of keratoconus in Asir Province, Saudi Arabia, is high with an early onset and more rapid progress to the severe disease stage at a young age. This might reflect the influence of genetic and/or environmental factor(s) in the aetiology of keratoconus.

  14. Incidence and severity of keratoconus in Asir province, Saudi Arabia

    PubMed Central

    Assiri, A A; Yousuf, B I; Quantock, A J; Murphy, P J

    2005-01-01

    Aim: To assess the incidence and associated signs and symptoms of patients with keratoconus in Asir Province, Saudi Arabia. Methods: 125 new keratoconus patients (51 male, 74 female; mean age 18.5 (SD 3.8) years; range 8–28 years) were recruited from referrals to the department of ophthalmology, Asir Central Hospital, over a 1 year period. Age, visual acuity, and keratometry were recorded along with clinical signs and symptoms. Results: The incidence of keratoconus in Asir Province is 20 cases per 100 000 population. Also, the disease severity is high, as indicated by an early mean age (17.7 (3.6) years) with advanced stage keratoconus. Visual acuity, with either spectacles or rigid contact lenses, was 6/12 or better in 98% of eyes measured. Just over half (56%) of patients had atopic ocular disease. 16% of patients had a positive family history of the disease and 16% had atopic dermatitis (eczema and/or vitiligo). Conclusion: The incidence and severity of keratoconus in Asir Province, Saudi Arabia, is high with an early onset and more rapid progress to the severe disease stage at a young age. This might reflect the influence of genetic and/or environmental factor(s) in the aetiology of keratoconus. PMID:16234439

  15. Simulating Photo-Refraction Images of Keratoconus and Near-Sightedness Eyes

    NASA Astrophysics Data System (ADS)

    Baker, Kevin; Lewis, James W. L.; Chen, Ying-Ling

    2004-11-01

    Keratoconus is an abnormal condition of the eye resulting from cone-shaped features on the cornea that degrade the quality of vision. These corneal features result from thinning and subsequent bulging due to intraocular pressure. The abnormal corneal curvature increases the refractive power asymmetrically and can be misdiagnosed by examiners as astigmatism and nearsightedness. Since corrective treatment is possible, early detection of this condition is desirable. Photo-refraction (PR) detects the retinal irradiance reflected from a single light source and is an inexpensive method used to identify refractive errors. For near- (far-) sighted eye, a crescent appears on the same (opposite) side of the light source. The capability of a PR device to detect keratoconus and to differentiate this condition from myopia was investigated. Using a commercial optical program, synthetic eye models were constructed for both near-sighted and keratoconus eyes. PR images of various eye conditions were calculated. The keratoconus cone shapes were modeled with typical published cone locations and sizes. The results indicate significant differences between the images of keratoconus and near-sighted eyes.

  16. Quantitative analysis of iris parameters in keratoconus patients using optical coherence tomography.

    PubMed

    Bonfadini, Gustavo; Arora, Karun; Vianna, Lucas M; Campos, Mauro; Friedman, David; Muñoz, Beatriz; Jun, Albert S

    2015-01-01

    To investigate the relationship between quantitative iris parameters and the presence of keratoconus. Cross-sectional observational study that included 15 affected eyes of 15 patients with keratoconus and 26 eyes of 26 normal age- and sex-matched controls. Iris parameters (area, thickness, and pupil diameter) of affected and unaffected eyes were measured under standardized light and dark conditions using anterior segment optical coherence tomography (AS-OCT). To identify optimal iris thickness cutoff points to maximize the sensitivity and specificity when discriminating keratoconus eyes from normal eyes, the analysis included the use of receiver operating characteristic (ROC) curves. Iris thickness and area were lower in keratoconus eyes than in normal eyes. The mean thickness at the pupillary margin under both light and dark conditions was found to be the best parameter for discriminating normal patients from keratoconus patients. Diagnostic performance was assessed by the area under the ROC curve (AROC), which had a value of 0.8256 with 80.0% sensitivity and 84.6% specificity, using a cutoff of 0.4125 mm. The sensitivity increased to 86.7% when a cutoff of 0.4700 mm was used. In our sample, iris thickness was lower in keratoconus eyes than in normal eyes. These results suggest that tomographic parameters may provide novel adjunct approaches for keratoconus screening.

  17. An affordable and easy-to-use diagnostic method for keratoconus detection using a smartphone

    NASA Astrophysics Data System (ADS)

    Askarian, Behnam; Tabei, Fatemehsadat; Askarian, Amin; Chong, Jo Woon

    2018-02-01

    Recently, smartphones are used for disease diagnosis and healthcare. In this paper, we propose a novel affordable diagnostic method of detecting keratoconus using a smartphone. Keratoconus is usually detected in clinics with ophthalmic devices, which are large, expensive and not portable, and need to be operated by trained technicians. However, our proposed smartphone-based eye disease detection method is small, affordable, portable, and it can be operated by patients in a convenient way. The results show that the proposed keratoconus detection method detects severe, advanced, and moderate keratoconus with accuracies of 93%, 86%, 67%, respectively. Due to its convenience with these accuracies, the proposed keratoconus detection method is expected to be applied in detecting keratoconus at an earlier stage in an affordable way.

  18. Simplified refracting technique in keratoconus.

    PubMed

    Gasset, A R

    1975-01-01

    A simple but effective technique to refract keratoconus patients is presented. The theoretical objection to these methods are discussed. In addition, a formula to calculate lenticular astigmatism is presented.

  19. Noonan's syndrome with keratoconus and optic disc coloboma.

    PubMed

    Ascaso, F J; Del Buey, M A; Huerva, V; Latre, B; Palomar, A

    1993-01-01

    We report the case of a 14-year-old girl with multiple findings characteristic of Noonan's syndrome, including short stature, mild mental retardation, facial, skeletal and renal abnormalities. In addition, ophthalmic examination revealed a keratoconus in the left eye and a right optic disc coloboma. To date, only two cases of Noonan's syndrome with keratoconus have been reported, and this is the second case of this syndrome with optic disc coloboma. To our knowledge, this is the first report of Noonan's syndrome associated with unilateral keratoconus and contralateral optic disc coloboma. In view of the large number of patients with Noonan's syndrome reported to date and the rarity of these ocular abnormalities, it is most likely that this association is fortuitous. Ocular findings reported in patients with Noonan's syndrome are reviewed.

  20. A new approach to keratoconus detection based on corneal morphogeometric analysis

    PubMed Central

    Bataille, Laurent; Fernández-Pacheco, Daniel G.; Cañavate, Francisco J. F.; Alió, Jorge L.

    2017-01-01

    Purpose To characterize corneal structural changes in keratoconus using a new morphogeometric approach and to evaluate its potential diagnostic ability. Methods Comparative study including 464 eyes of 464 patients (age, 16 and 72 years) divided into two groups: control group (143 healthy eyes) and keratoconus group (321 keratoconus eyes). Topographic information (Sirius, CSO, Italy) was processed with SolidWorks v2012 and a solid model representing the geometry of each cornea was generated. The following parameters were defined: anterior (Aant) and posterior (Apost) corneal surface areas, area of the cornea within the sagittal plane passing through the Z axis and the apex (Aapexant, Aapexpost) and minimum thickness points (Amctant, Amctpost) of the anterior and posterior corneal surfaces, and average distance from the Z axis to the apex (Dapexant, Dapexpost) and minimum thickness points (Dmctant, Dmctpost) of both corneal surfaces. Results Significant differences among control and keratoconus group were found in Aapexant, Aapexpost, Amctant, Amctpost, Dapexant, Dapexpost (all p<0.001), Apost (p = 0.014), and Dmctpost (p = 0.035). Significant correlations in keratoconus group were found between Aant and Apost (r = 0.836), Amctant and Amctpost (r = 0.983), and Dmctant and Dmctpost (r = 0.954, all p<0.001). A logistic regression analysis revealed that the detection of keratoconus grade I (Amsler Krumeich) was related to Apost, Atot, Aapexant, Amctant, Amctpost, Dapexpost, Dmctant and Dmctpost (Hosmer-Lemeshow: p>0.05, R2 Nagelkerke: 0.926). The overall percentage of cases correctly classified by the model was 97.30%. Conclusions Our morphogeometric approach based on the analysis of the cornea as a solid is useful for the characterization and detection of keratoconus. PMID:28886157

  1. A new approach to keratoconus detection based on corneal morphogeometric analysis.

    PubMed

    Cavas-Martínez, Francisco; Bataille, Laurent; Fernández-Pacheco, Daniel G; Cañavate, Francisco J F; Alió, Jorge L

    2017-01-01

    To characterize corneal structural changes in keratoconus using a new morphogeometric approach and to evaluate its potential diagnostic ability. Comparative study including 464 eyes of 464 patients (age, 16 and 72 years) divided into two groups: control group (143 healthy eyes) and keratoconus group (321 keratoconus eyes). Topographic information (Sirius, CSO, Italy) was processed with SolidWorks v2012 and a solid model representing the geometry of each cornea was generated. The following parameters were defined: anterior (Aant) and posterior (Apost) corneal surface areas, area of the cornea within the sagittal plane passing through the Z axis and the apex (Aapexant, Aapexpost) and minimum thickness points (Amctant, Amctpost) of the anterior and posterior corneal surfaces, and average distance from the Z axis to the apex (Dapexant, Dapexpost) and minimum thickness points (Dmctant, Dmctpost) of both corneal surfaces. Significant differences among control and keratoconus group were found in Aapexant, Aapexpost, Amctant, Amctpost, Dapexant, Dapexpost (all p<0.001), Apost (p = 0.014), and Dmctpost (p = 0.035). Significant correlations in keratoconus group were found between Aant and Apost (r = 0.836), Amctant and Amctpost (r = 0.983), and Dmctant and Dmctpost (r = 0.954, all p<0.001). A logistic regression analysis revealed that the detection of keratoconus grade I (Amsler Krumeich) was related to Apost, Atot, Aapexant, Amctant, Amctpost, Dapexpost, Dmctant and Dmctpost (Hosmer-Lemeshow: p>0.05, R2 Nagelkerke: 0.926). The overall percentage of cases correctly classified by the model was 97.30%. Our morphogeometric approach based on the analysis of the cornea as a solid is useful for the characterization and detection of keratoconus.

  2. Autorefraction Versus Manifest Refraction in Patients With Keratoconus.

    PubMed

    Soeters, Nienke; Muijzer, Marc B; Molenaar, Jurrian; Godefrooij, Daniel A; Wisse, Robert P L

    2018-01-01

    To compare visual performance using autorefraction and manifest refraction assessments in patients with keratoconus and investigate whether autorefraction measurements lead to suboptimal visual performance. Corrected distance visual acuity (CDVA) was measured in 90 eyes of 61 patients with keratoconus with both autorefraction and manifest refraction, in a random order. Maximum keratometry (Kmax), cone location, and wavefront aberration were determined with Scheimpflug tomography. The difference between the autorefraction and manifest refraction outcomes was converted to vectors and a multivariable analysis was performed to identify potential underlying causes of this difference. A significantly better CDVA was achieved with manifest refraction (0.06 vs 0.29 logMAR [20/23 vs 20/38 Snellen], P < .001). After vector analysis, a mean difference of 4.83 diopters was found between autorefraction and manifest refraction. Increased Kmax was strongly and significantly associated with better visual performance of manifest refraction compared to autorefraction (B = 0.496, P = .002). This study showed that a superior CDVA is achieved with manifest refraction compared to autorefraction in patients with keratoconus. Furthermore, the difference between the two refraction methods increases as the cornea steepens. According to this study, autorefraction is unreliable in patients with keratoconus and should be avoided. [J Refract Surg. 2018;34(1):30-34.]. Copyright 2018, SLACK Incorporated.

  3. Scanning-slit topography in patients with keratoconus.

    PubMed

    Módis, László; Németh, Gábor; Szalai, Eszter; Flaskó, Zsuzsa; Seitz, Berthold

    2017-01-01

    To evaluate the anterior and posterior corneal surfaces using scanning-slit topography and to determine the diagnostic ability of the measured corneal parameters in keratoconus. Orbscan II measurements were taken in 39 keratoconic corneas previously diagnosed by corneal topography and in 39 healthy eyes. The central minimum, maximum, and astigmatic simulated keratometry (K) and anterior axial power values were determined. Spherical and cylindrical mean power diopters were obtained at the central and at the steepest point of the cornea both on anterior and on posterior mean power maps. Pachymetry evaluations were taken at the center and paracentrally in the 3 mm zone from the center at a location of every 45 degrees. Receiver operating characteristic (ROC) analysis was used to determine the best cut-off values and to evaluate the utility of the measured parameters in identifying patients with keratoconus. The minimum, maximum and astigmatic simulated K readings were 44.80±3.06 D, 47.17±3.67 D and 2.42±1.84 D respectively in keratoconus patients and these values differed significantly ( P <0.0001 for all comparisons) from healthy subjects. For all pachymetry measurements and for anterior and posterior mean power values significant differences were found between the two groups. Moreover, anterior central cylindrical power had the best discrimination ability (area under the ROC curve=0.948). The results suggest that scanning-slit topography and pachymetry are accurate methods both for keratoconus screening and for confirmation of the diagnosis.

  4. Proteases, proteolysis and inflammatory molecules in the tears of people with keratoconus.

    PubMed

    Balasubramanian, Sivaraman Arumugam; Mohan, Sujatha; Pye, David Cecil; Willcox, Mark Duncan Perry

    2012-06-01

    To investigate the expression of proteases, proteolytic activity and cytokines in the tear film of people with keratoconus. Basal tears from people with keratoconus, from individuals who had undergone corneal collagen cross-linking for the treatment of keratoconus, and from normal controls were collected using a capillary tube. Corneal curvature of each subject was mapped. The total protein in tears was estimated. Levels and activity of proteases in the tears were analysed using specific antibody arrays and activity assays. The total tear protein level was significantly reduced in keratoconus (4.1 ± 0.9 mg/ml) compared with normals (6.7 ± 1.4 mg/ml) (p < 0.0001) or subjects who had undergone corneal collagen cross-linking (5.7 ± 2.3 mg/ml) (p < 0.005). Significantly (p < 0.05) increased tear expression of matrix metalloproteinases (MMP) -1, -3, -7, -13, interleukins (IL) -4, -5, -6, -8 and tumour necrosis factor (TNF) -α, -β were evident in keratoconus. Tear IL-6 was the only cytokine significantly (p < 0.05) increased in tears of keratoconus subjects compared with the collagen cross-linked group. No significant difference in tear proteases were observed between the normal and the cross-linked groups, although the expression of TNF-α was significantly (p < 0.05) increased in the cross-linked group compared with the controls. Elevated gelatinolytic (87.5 ± 33.6 versus 45.8 ± 24.6 FIU, p < 0.0001) and collagenolytic (6.1 ± 3.2 versus 3.6 ± 2.0 FIU, p < 0.05) activities were observed in tears from keratoconus compared with normal subjects. The activity of tear gelatinases (69.6 ± 22.2 FIU) and collagenases (5.7 ± 3.3 FIU) in the collagen cross-linked group was not significantly different compared with either keratoconus or normals. Tears of people with keratoconus had 1.9 times higher levels of proteolytic activity and over expression of several MMPs and cytokines compared with tears from controls. Further investigations are required to study the possible

  5. [Evaluation of corneal biomechanics in keratoconus using dynamic ultra-high-speed Scheimpflug measurements].

    PubMed

    Brettl, S; Franko Zeitz, P; Fuchsluger, T A

    2018-06-22

    The in vivo analysis of corneal biomechanics in patients with keratoconus is especially of interest with respect to diagnosis, follow-up and monitoring of the disease. For a better understanding it is necessary to describe the potential of dynamic Scheimpflug measurements for the detection and interpretation of biomechanical changes in keratoconus. The current state of analyzing biomechanical changes in keratoconus with the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) is described. This technique represents a new approach for understanding corneal biomechanics. Furthermore, it was investigated whether the device can biomechanically quantify a rigidity increasing effect of therapeutic UV-crosslinking and whether early stages of keratoconus can be detected using dynamic Scheimpflug analysis. In patients with keratoconus, the in vivo analysis of corneal biomechanics using dynamic Scheimpflug measurements as a supplementary procedure can be of advantage with respect to disease management. By optimization of screening of subclinical keratoconus stages, this method widens the analytic spectrum regarding diagnosis and follow-up of the disease; however, further studies are required to evaluate whether visual outcome of affected patients can be improved by earlier diagnosis.

  6. LogMAR and Stereoacuity in Keratoconus Corrected with Spectacles and Rigid Gas-permeable Contact Lenses.

    PubMed

    Nilagiri, Vinay Kumar; Metlapally, Sangeetha; Kalaiselvan, Parthasarathi; Schor, Clifton M; Bharadwaj, Shrikant R

    2018-04-01

    This study showed an improvement in three-dimensional depth perception of subjects with bilateral and unilateral keratoconus with rigid gas-permeable (RGP) contact lens wear, relative to spectacles. This novel information will aid clinicians to consider RGP contact lenses as a management modality in keratoconic patients complaining of depth-related difficulties with their spectacles. The aim of this study was to systematically compare changes in logMAR acuity and stereoacuity from best-corrected spherocylindrical spectacles to RGP contact lenses in bilateral and unilateral keratoconus vis-à-vis age-matched control subjects. Monocular and binocular logMAR acuity and random-dot stereoacuity were determined in subjects with bilateral (n = 30; 18 to 24 years) and unilateral (n = 10; 18 to 24 years) keratoconus and 20 control subjects using standard psychophysical protocols. Median (25th to 75th interquartile range) monocular (right eye) and binocular logMAR acuity and stereoacuity improved significantly from spectacles to RGP contact lenses in the bilateral keratoconus cohort (P < .001). Only monocular logMAR acuity of affected eye and stereoacuity improved from spectacles to RGP contact lenses in the unilateral keratoconus cohort (P < .001). There was no significant change in the binocular logMAR acuity from spectacles to RGP contact lenses in the unilateral keratoconus cohort. The magnitude of improvement in binocular logMAR acuity and stereoacuity was also greater for the bilateral compared with the unilateral keratoconus cohort. All outcome measures of cases with RGP contact lenses remained poorer than control subjects (P < .001). Binocular resolution and stereoacuity improve from spectacles to RGP contact lenses in bilateral keratoconus, whereas only stereoacuity improves from spectacles to RGP contact lenses in unilateral keratoconus. The magnitude of improvement in visual performance is greater for the binocular compared with the unilateral keratoconus cohort.

  7. Interleukin 1 beta promoter polymorphism is associated with keratoconus in a Japanese population

    PubMed Central

    Mikami, Takenori; Teshigawara, Takeshi; Takeuchi, Masaki; Uemoto, Riyo; Kawagoe, Tatsukata; Nomura, Eiichi; Asukata, Yuri; Ishioka, Misaki; Iwasaki, Miki; Fukagawa, Kazumi; Konomi, Kenji; Shimazaki, Jun; Nishida, Teruo; Mizuki, Nobuhisa

    2013-01-01

    Purpose Polymorphisms in the interleukin 1 alpha (IL1A) and IL1B gene regions were previously associated with keratoconus in a Korean population. In the present study, we investigated whether the IL1A and IL1B polymorphisms are associated with keratoconus in a Japanese population. Methods A total of 169 Japanese patients with keratoconus and 390 Japanese healthy controls were recruited. We genotyped one IL1A single nucleotide polymorphism (SNP; rs2071376) and two IL1B SNPs (rs1143627 and rs16944) to compare the frequencies of alleles, genotypes, and haplotypes between cases and controls. Results Statistically significant association was observed for rs1143627 (−31 T>C) in the IL1B promoter region; the T allele of rs1143627 was associated with an increased risk of keratoconus (p=0.014, corrected p value [pc]=0.043, odds ratio=1.38). The C allele of rs16944 (−511 C>T) in the IL1B promoter region had a 1.33-fold increased risk of keratoconus, although this increase did not reach statistical significance (p=0.033, pc=0.098). The TT genotype of rs1143627 was weakly associated with an increased risk of keratoconus (p=0.033, pc=0.099, odds ratio=1.52). However, no significant differences were found in the allele and genotype frequencies between the cases and controls for rs2071376 in IL1A. Regarding haplotypic diversity, the haplotype created by the T allele of rs1143627 and C allele of rs16944 was associated with a 1.72-fold increased risk of keratoconus (p=4.0×10−5, pc=1.6×10−4). Conclusions Our results replicate associations reported recently in a Korean population. Thus, IL1B may play an important role in the development of keratoconus through genetic polymorphisms. PMID:23592922

  8. Interleukin 1 beta promoter polymorphism is associated with keratoconus in a Japanese population.

    PubMed

    Mikami, Takenori; Meguro, Akira; Teshigawara, Takeshi; Takeuchi, Masaki; Uemoto, Riyo; Kawagoe, Tatsukata; Nomura, Eiichi; Asukata, Yuri; Ishioka, Misaki; Iwasaki, Miki; Fukagawa, Kazumi; Konomi, Kenji; Shimazaki, Jun; Nishida, Teruo; Mizuki, Nobuhisa

    2013-01-01

    Polymorphisms in the interleukin 1 alpha (IL1A) and IL1B gene regions were previously associated with keratoconus in a Korean population. In the present study, we investigated whether the IL1A and IL1B polymorphisms are associated with keratoconus in a Japanese population. A total of 169 Japanese patients with keratoconus and 390 Japanese healthy controls were recruited. We genotyped one IL1A single nucleotide polymorphism (SNP; rs2071376) and two IL1B SNPs (rs1143627 and rs16944) to compare the frequencies of alleles, genotypes, and haplotypes between cases and controls. Statistically significant association was observed for rs1143627 (-31 T>C) in the IL1B promoter region; the T allele of rs1143627 was associated with an increased risk of keratoconus (p=0.014, corrected p value [pc]=0.043, odds ratio=1.38). The C allele of rs16944 (-511 C>T) in the IL1B promoter region had a 1.33-fold increased risk of keratoconus, although this increase did not reach statistical significance (p=0.033, pc=0.098). The TT genotype of rs1143627 was weakly associated with an increased risk of keratoconus (p=0.033, pc=0.099, odds ratio=1.52). However, no significant differences were found in the allele and genotype frequencies between the cases and controls for rs2071376 in IL1A. Regarding haplotypic diversity, the haplotype created by the T allele of rs1143627 and C allele of rs16944 was associated with a 1.72-fold increased risk of keratoconus (p=4.0×10(-5), pc=1.6×10(-4)). Our results replicate associations reported recently in a Korean population. Thus, IL1B may play an important role in the development of keratoconus through genetic polymorphisms.

  9. The influence of gender and hormone status on the severity and progression of keratoconus.

    PubMed

    Fink, Barbara A; Sinnott, Loraine T; Wagner, Heidi; Friedman, Chad; Zadnik, Karla

    2010-01-01

    To assess the effects of gender and hormone status on the severity and progression of keratoconus in patients enrolled in the Collaborative Longitudinal Evaluation of Keratoconus Study. The severity and progression of keratoconus in both men (M) and women were evaluated over a 4-year period that encompassed menopausal transition for hormone-active women (HA) and hormone-inactive women (HI). Four outcome measures were selected as indicators of the severity of keratoconus: high-contrast best-corrected visual acuity, low-contrast best-corrected visual acuity, the steep keratometric measurement, and corneal scarring (yes/no). There were no statistically significant differences among the 3 groups (M, HA, and HI) in race, history of atopic disease, family history of keratoconus, or rigid contact lens wear in the right and left eyes. At baseline, there were no significant differences among the 3 groups in high-contrast best-corrected visual acuity, low-contrast best-corrected visual acuity, or steep keratometric reading. Progression of keratoconus, as assessed by changes in these 3 continuous variables, was equal for the 3 groups. M had more corneal scarring than did HA or HI; however, there was no progression of scarring for any of the groups. Keratoconus progressed in both men and women, aged 48-59 years; however, there were no differences among the groups in progression.

  10. Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography

    PubMed Central

    Li, Yan; Chamberlain, Winston; Tan, Ou; Brass, Robert; Weiss, Jack L.; Huang, David

    2016-01-01

    PURPOSE To screen for subclinical keratoconus by analyzing corneal, epithelial, and stromal thickness map patterns with Fourier-domain optical coherence tomography (OCT). SETTING Four centers in the United States. DESIGN Cross-sectional observational study. METHODS Eyes of normal subjects, subclinical keratoconus eyes, and the topographically normal eye of a unilateral keratoconus patient were studied. Corneas were scanned using a 26 000 Hz Fourier-domain OCT system (RTVue). Normal subjects were divided into training and evaluation groups. Corneal, epithelial, and stromal thickness maps and derived diagnostic indices, including pattern standard deviation (PSD) variables and pachymetric map–based keratoconus risk scores were calculated from the OCT data. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic accuracy of the indices. RESULTS The study comprised 150 eyes of 83 normal subjects, 50 subclinical keratoconus eyes of 32 patients, and 1 topographically normal eye of a unilateral keratoconus patient. Subclinical keratoconus was characterized by inferotemporal thinning of the cornea, epithelium, and stroma. The PSD values for corneal (P < .001), epithelial (P < .001), and stromal (P = .049) thickness maps were all significantly higher in subclinical keratoconic eyes than in the normal group. The diagnostic accuracy was significantly higher for PSD variables (pachymetric PSD, AUC = 0.941; epithelial PSD, AUC = 0.985; stromal PSD, AUC = 0.924) than for the pachymetric map–based keratoconus risk score (AUC = 0.735). CONCLUSIONS High-resolution Fourier-domain OCT could map corneal, epithelial, and stromal thicknesses. Corneal and sublayer thickness changes in subclinical keratoconus could be detected with high accuracy using PSD variables. These new diagnostic variables might be useful in the detection of early keratoconus. PMID:27026454

  11. Keratoconus in Civil Aviation Pilots in a Report of Six Cases.

    PubMed

    Rebello, Albert; Rodrigues, Bênesson; Pereira, Marcos

    2017-06-01

    Keratoconus is a progressive noninflammatory ectatic corneal dystrophy, characterized by corneal thinning and increased curvature with central or paracentral tapered protrusion. Such changes in corneal morphology induce irregular astigmatism and myopia, resulting in visual acuity impairment. This report assesses cases in which keratoconus is not an absolute disabling condition for civil aviation pilots. Six cases of keratoconus in active pilots are presented. This report includes cases which were treated with crosslinking therapy and even corneal transplantation. In such cases, the civil aviation medical authority considered four aspects in the medical assessment: best corrected visual acuity, condition stability, risk of sudden incapacitation, and pilot category. Six civil pilots with ages between 19 and 45 yr of age presented with keratoconus in different stages. Using the Snellen scale, best corrected visual acuity (BCVA) was measured in 12 eyes, all of them having equal or better than 20/30 (20/20, N = 9; 20/25, N = 2; 20/30, N = 1). All of them are currently fit for aviation activity and have been given an aviation medical certificate with limitation of use of corrective lenses by the Brazilian Civil Aviation Authority (ANAC in Portuguese). Among these cases, there is a pilot who had undergone treatment with crosslinking therapy and another that had undergone corneal transplantation. These cases demonstrate that keratoconus is not always a disabling condition for civil aviation pilots. Nevertheless, it has to be analyzed on a case-by-case basis.Rebello A, Rodrigues B, Pereira M. Keratoconus in civil aviation pilots in a report of six cases. Aerosp Med Hum Perform. 2017; 88(6):574-578.

  12. [Keratoconus special soft contact lens fitting].

    PubMed

    Yamazaki, Ester Sakae; da Silva, Vanessa Cristina Batista; Morimitsu, Vagner; Sobrinho, Marcelo; Fukushima, Nelson; Lipener, César

    2006-01-01

    To evaluate the fitting and use of a soft contact lens in keratoconic patients. Retrospective study on 80 eyes of 66 patients, fitted with a special soft contact lens for keratoconus, at the Contact Lens Section of UNIFESP and private clinics. Keratoconus was classified according to degrees of disease severity by keratometric pattern. Age, gender, diagnosis, keratometry, visual acuity, spherical equivalent (SE), base curve and clinical indication were recorded. Of 66 patients (80 eyes) with keratoconus the mean age was 29 years, 51.5% were men and 48.5% women. According to the groups: 15.0% were incipient, 53.7% moderate, 26.3% advanced and 5.0% were severe. The majority of the eyes of patients using contact lenses (91.25%) achieved visual acuity better than 20/40. To 88 eyes 58% were tihed with lens with spherical power (mean -5.45 diopters) and 41% with spherocylinder power (from -0.5 to -5.00 cylindrical diopters). The most frequent base curve was 7.6 in 61% of the eyes. The main reasons for this special lens fitting were due to reduced tolerance and poor fitting pattern achieved with other lenses. The special soft contact lens is useful in fitting difficult keratoconic patients by offering comfort and improving visual rehabilitation that may allow more patients to postpone the need for corneal transplant.

  13. Safety and efficacy of collagen crosslinking for the treatment of keratoconus.

    PubMed

    Kolli, Sai; Aslanides, Ioannis M

    2010-11-01

    Keratoconus is a condition that causes corneal ectasia and reduced vision in young adults. A proportion of these patients have progressive disease requiring corneal transplantation. A revolutionary new treatment that is purported to halt progression of keratoconus, known as collagen crosslinking (CXL), has recently been introduced into clinical practice. CXL involves the treatment of the cornea with riboflavin followed by photoactivation with UVA light leading to corneal strengthening. This article reviews the basic science, clinical protocols, safety aspects and clinical results of CXL. The reader will gain a comprehensive understanding of: i) the basic science of CXL; ii) the optimised protocols for clinical use of CXL; iii) the results of all the main clinical trials in the literature; iv) contraindications to treatment and v) full clinical safety profile of CXL. CXL represents a new treatment that uniquely allows the halt of progression of keratoconus, thus preventing visual loss and the need for surgical intervention. Available data suggest that this treatment has high efficacy and is very safe and may represent the future standard treatment for progressive keratoconus.

  14. Cataract and keratoconus: minimizing complications in intraocular lens calculations.

    PubMed

    Bozorg, Sara; Pineda, Roberto

    2014-01-01

    Patients with both cataract and keratoconus present unique challenges for the surgeon. Accurate keratometry (K) and axial length (AL) readings may be impossible, and uncertainty is introduced when estimating the corneal power for intraocular lens (IOL) selection. Different options on how to choose an IOL and how to manage irregular astigmatism of a keratoconic patient with cataract have been proposed and are reviewed. The stage of keratoconus and the history of the patient are both critical in determining the strategy used in treatment of cataracts.

  15. Urea, Uric Acid, Prolactin and fT4 Concentrations in Aqueous Humor of Keratoconus Patients.

    PubMed

    Stachon, Tanja; Stachon, Axel; Hartmann, Ulrike; Seitz, Berthold; Langenbucher, Achim; Szentmáry, Nóra

    2017-06-01

    Keratoconus is a noninflammatory disease of the cornea associated with progressive thinning and conical shape. Metabolic alterations in the urea cycle, with changes in collagen fibril stability, oxidative stress, thyroid hormones and prolactin with regulatory effect on biosynthesis and biomechanical stability of corneal stroma, may all play a role in keratoconus etiology. Our purpose was to determine urea, uric acid, prolactin and free thyroxin (fT4) concentrations in human aqueous humor (hAH) of keratoconus and cataract patients. hAH was collected from 100 keratoconus (penetrating keratoplasty) (41.9 ± 14.9 years, 69 males) and 100 cataract patients (cataract surgery) (71.2 ± 12.4 years, 58 males). Urea, uric acid, prolactin and fT4 concentrations were measured by Siemens clinical chemistry or immunoassay system. For statistical analysis, a generalized linear model (GLM) was used. Urea concentration was 11.88 ± 3.03 mg/dl in keratoconus and 16.44 ± 6.40 mg/dl in cataract patients, uric acid 2.04 ± 0.59 mg/dl in keratoconus and 2.18 ± 0.73 mg/dl in cataract groups. Prolactin concentration was 3.18 ± 0.34 ng/ml in keratoconus and 3.33 ± 0.32 ng/ml in cataract patients, fT4 20.57 ± 4.76 pmol/l in KC and 19.06 ± 3.86 pmol/l in cataract group. Urea concentration was effected through gender (p = 0.039), age (p = 0.001) and diagnosis (p = 0.025). Uric acid concentration was not effected through any of the analyzed parameters (p > 0.056). Prolactin and fT4 concentration were effected only through diagnosis (p = 0.009 and p = 0.006). Urea and prolactin concentrations are decreased, fT4 concentration is increased in aqueous humor of keratoconus patients, and uric acid concentration remains unchanged. Urea concentration in aqueous humor is also increased in older and male patients. Therefore, metabolic disorder and hormonal balance may both have an impact on keratoconus development. Further studies are necessary to assess the specific impact.

  16. Intracameral air injection for acute hydrops in keratoconus.

    PubMed

    Miyata, Kazunori; Tsuji, Hideki; Tanabe, Tatsuro; Mimura, Yoshiko; Amano, Shiro; Oshika, Tetsuro

    2002-06-01

    To evaluate the efficacy and safety of intracameral air injection in treating acute hydrops in keratoconus. Retrospective, nonrandomized, comparative trial. Thirty eyes (30 patients) with acute hydrops secondary to keratoconus. Nine eyes (nine patients) with acute hydrops in keratoconus were treated with intracameral injection of 0.1 ml filtered air. Additional 0.1 ml filtered air was injected if corneal edema persisted when air disappeared from the anterior chamber. Twenty-one eyes (21 patients) with acute hydrops that received no therapy or conventional therapy not likely to shorten the duration of hydrops served as controls. The period of persistence of corneal edema, the interval between the onset of acute hydrops, and the time when the eye could begin to wear a hard-contact lens, and best spectacle-corrected and hard-contact lens-corrected visual acuity after corneal edema subsided were used as criteria to evaluate any differences between the two groups. The average period of persistence of corneal edema was 20.1 +/- 9.0 days (+/- SD) in the intracameral air injection group and 64.7 +/- 34.6 days in the control (P =.0008). The average interval between the onset of acute hydrops and the time when the eye could begin to wear a hard-contact lens, was 33.4 +/- 5.6 days in the air injection group and 128.9 +/- 85.8 days in the control group (P =.0058). The best-corrected visual acuity after corneal edema subsided was similar between the two groups. Intracameral air injection induced no complications. The results suggest that the intracameral air injection is a safe and useful therapy to shorten the period of corneal edema in acute hydrops secondary to keratoconus.

  17. [Comparison of Discriminant Analysis and Decision Trees for the Detection of Subclinical Keratoconus].

    PubMed

    Kleinhans, Sonja; Herrmann, Eva; Kohnen, Thomas; Bühren, Jens

    2017-08-15

    Background Iatrogenic keratectasia is one of the most dreaded complications of refractive surgery. In most cases, keratectasia develops after refractive surgery of eyes suffering from subclinical stages of keratoconus with few or no signs. Unfortunately, there has been no reliable procedure for the early detection of keratoconus. In this study, we used binary decision trees (recursive partitioning) to assess their suitability for discrimination between normal eyes and eyes with subclinical keratoconus. Patients and Methods The method of decision tree analysis was compared with discriminant analysis which has shown good results in previous studies. Input data were 32 eyes of 32 patients with newly diagnosed keratoconus in the contralateral eye and preoperative data of 10 eyes of 5 patients with keratectasia after laser in-situ keratomileusis (LASIK). The control group was made up of 245 normal eyes after LASIK and 12-month follow-up without any signs of iatrogenic keratectasia. Results Decision trees gave better accuracy and specificity than did discriminant analysis. The sensitivity of decision trees was lower than the sensitivity of discriminant analysis. Conclusion On the basis of the patient population of this study, decision trees did not prove to be superior to linear discriminant analysis for the detection of subclinical keratoconus. Georg Thieme Verlag KG Stuttgart · New York.

  18. Keratoconus presenting with bilateral simultaneous acute corneal hydrops.

    PubMed

    Bilgin, Burak; Unal, Betül; Unal, Mustafa; Doğan, Erkan; Cetinkaya, Aslı; Akyol, Mahmut; Yücel, Iclal; Akar, Yusuf; Apaydın, Cemil; Ilhan, Deniz

    2013-04-01

    To report a case of unknown keratoconus presenting with bilateral simultaneous acute corneal hydrops. Case report. A case of a 12-year-old male patient with Leber congenital amaurosis (LCA) presented with sudden whitening and lacrimation for 2 days in both eyes simultaneously. At the initial examination, there were bilateral acute corneal hydrops, enophthalmic eyes and roving nystagmus. Ultrasonography revealed clear crystalline lenses and attached retina. Initial management consisted of topical hypertonic solutions, steroids and artificial tears. Bilateral simultaneous acute corneal hydrops has not been reported before in the literature. It may be the presenting sign of keratoconus. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Surgical Options for the Refractive Correction of Keratoconus: Myth or Reality

    PubMed Central

    Zaldivar, R.; Aiello, F.; Madrid-Costa, D.

    2017-01-01

    Keratoconus provides a decrease of quality of life to the patients who suffer from it. The treatment used as well as the method to correct the refractive error of these patients may influence on the impact of the disease on their quality of life. The purpose of this review is to describe the evidence about the conservative surgical treatment for keratoconus aiming to therapeutic and refractive effect. The visual rehabilitation for keratoconic corneas requires addressing three concerns: halting the ectatic process, improving corneal shape, and minimizing the residual refractive error. Cross-linking can halt the disease progression, intrastromal corneal ring segments can improve the corneal shape and hence the visual quality and reduce the refractive error, PRK can correct mild-moderate refractive error, and intraocular lenses can correct from low to high refractive error associated with keratoconus. Any of these surgical options can be performed alone or combined with the other techniques depending on what the case requires. Although it could be considered that the surgical option for the refracto-therapeutic treatment of the keratoconus is a reality, controlled, randomized studies with larger cohorts and longer follow-up periods are needed to determine which refractive procedure and/or sequence are most suitable for each case. PMID:29403662

  20. Correlation of higher order aberrations in the anterior corneal surface and degree of keratoconus measured with a Scheimpflug camera.

    PubMed

    Delgado, S; Velazco, J; Delgado Pelayo, R M; Ruiz-Quintero, N

    2016-07-01

    To determine the correlation of higher order aberrations in anterior corneal surface and degree of keratoconus measured with a Scheimpflug camera. A descriptive, cross-sectional study was conducted on 152 eyes (both eyes of each patient) of patients with keratoconus, from January 2009 to April 2014. An examination was performed on the corneal aberrometry in the anterior corneal surface, and topographic mapping (by Amsler and Muckenhirn classification) was used to determine the degree of keratoconus. The correlation between high-order aberrations in anterior corneal surface and the degree of keratoconus was determined. Coma aberration significantly correlated with keratoconus severity (r=.60, P<.01), as well as with the high order aberration (r=.61, P<.01). Trefoil and keratoconus were weakly correlated (r=.34, P<.01). Higher order aberrations in anterior corneal surface were positively correlated with the degree of keratoconus in a similar way to the entire optical system. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  1. Transepithelial photorefractive keratectomy with crosslinking for keratoconus.

    PubMed

    Mukherjee, Achyut N; Selimis, Vasilis; Aslanides, Ioannis

    2013-01-01

    To analyse visual, refractive and topographic outcomes of combining transepithelial photorefractive keratectomy (tPRK) with simultaneous corneal crosslinking for the visual rehabilitation of contact lens intolerant keratoconus patients. Patients with topographically significant keratoconus, limited corrected vision and intolerant of contact lenses were prospectively recruited, subject to ethical approval and consent. All patients underwent single step aspheric tPRK and sequential crosslinking. Preoperative vision, refraction, corneal topography and wavefront were assessed, with postoperative assessment at 1, 3, 6, and 12 months. 22 eyes of 14 patients were included in the pilot study. Mean age was 32 years (SD 6.8, range 24 to 43). Mean preoperative unaided vision was 1.39 LogMAR (SD 0.5) best corrected 0.31 LogMAR (SD 0.2). Mean preoperative spherical equivalent was -2.74 Diopters (D) (SD 4.1 range -12.25 to +7.75), and mean cylinder -2.9 D (SD 1.2, range 0 to -5.5). Mean central corneal thickness was 461um (SD 29, range 411 to 516). Vision improved postoperatively; unaided 0.32 LogMAR (SD 0.4), best corrected 0.11 (SD 0.13) (P=<0.005). Mean postoperative cylinder was -1.4D (SD1.2), significantly reduced (p<0.005). Maximum keratometry (Kmax) was stable throughout postoperative follow up. (p<0.05). Non topographic transepithelial PRK with simultaneous crosslinking improves vision, and may offer an alternative to keratoplasty in contact lens intolerant keratoconus. Further comparative studies to topographic PRK techniques are indicated.

  2. Effect of Conus Eccentricity on Visual Outcomes After Intracorneal Ring Segments Implantation in Keratoconus.

    PubMed

    Gatzioufas, Zisis; Panos, Georgios D; Elalfy, Mohamed; Khine, Aye; Hamada, Samer; Lake, Damian; Kozeis, Nikos; Balidis, Miltos

    2018-03-01

    To investigate the potential impact of cone eccentricity on visual outcomes after Keraring (Mediphacos, Belo Horizonte, Brazil) implantation for keratoconus. Nineteen eyes from 19 patients with keratoconus who underwent femtosecond laser-assisted Keraring implantation for keratoconus were included in this retrospective study. Uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), keratometric readings, central corneal thickness, maximum keratometric distance from corneal apex (DKmax), corneal thinnest point from corneal apex (DTh), and coma were evaluated preoperatively and 6 months after the Keraring implantation. DKmax and DTh were used as metrics reflecting the eccentricity of the cone. UDVA, CDVA, keratometric readings, and coma improved at 6 months postoperatively. However, there was no correlation between DKmax or DTh and visual outcomes at 6 months postoperatively. The data did not show any impact of the cone eccentricity on visual outcomes after Keraring implantation for keratoconus at 6 months postoperatively. [J Refract Surg. 2018;34(3):196-200.]. Copyright 2018, SLACK Incorporated.

  3. New web-based algorithm to improve rigid gas permeable contact lens fitting in keratoconus.

    PubMed

    Ortiz-Toquero, Sara; Rodriguez, Guadalupe; de Juan, Victoria; Martin, Raul

    2017-06-01

    To calculate and validate a new web-based algorithm for selecting the back optic zone radius (BOZR) of spherical gas permeable (GP) lens in keratoconus eyes. A retrospective calculation (n=35; multiple regression analysis) and a posterior prospective validation (new sample of 50 keratoconus eyes) of a new algorithm to select the BOZR of spherical KAKC design GP lenses (Conoptica) in keratoconus were conducted. BOZR calculated with the new algorithm, manufacturer guidelines and APEX software were compared with the BOZR that was finally prescribed. Number of diagnostic lenses, ordered lenses and visits to achieve optimal fitting were recorded and compared those obtained for a control group [50 healthy eyes fitted with spherical GP (BIAS design; Conoptica)]. The new algorithm highly correlated with the final BOZR fitted (r 2 =0.825, p<0.001). BOZR of the first diagnostic lens using the new algorithm demonstrated lower difference with the final BOZR prescribed (-0.01±0.12mm, p=0.65; 58% difference≤0.05mm) than with the manufacturer guidelines (+0.12±0.22mm, p<0.001; 26% difference≤0.05mm) and APEX software (-0.14±0.16mm, p=0.001; 34% difference≤0.05mm). Close numbers of diagnostic lens (1.6±0.8, 1.3±0.5; p=0.02), ordered lens (1.4±0.6, 1.1±0.3; P<0.001), and visits (3.4±0.7, 3.2±0.4; p=0.08) were required to fit keratoconus and healthy eyes, respectively. This new algorithm (free access at www.calculens.com) improves spherical KAKC GP fitting in keratoconus and can reduce the practitioner and patient chair time to achieve a final acceptable fit in keratoconus. This algorithm reduces differences between keratoconus GP fitting (KAKC design) and standard GP (BIAS design) lenses fitting in healthy eyes. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology.

    PubMed

    Lunardi, Letícia Helena; Arroyo, Danielle; Andrade Sobrinho, Marcelo Vicente de; Lipener, César; Rosa, Juliana Maria da Silva

    2016-04-01

    Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the present study was to evaluate the association between keratoconus evolution grade and topography pattern and the type and design of fitted contact lens. We performed a retrospective analysis of contact lenses fitted in a total of 185 patients with keratoconus (325 eyes). Keratoconus was classified as either grade I, II, III, or IV based on keratometry and cone morphology (nipple, oval, globus, or indeterminate) results. A total of 325 eyes were evaluated in the present study. Of the 62 eyes classified as grade I, 66.1% were fitted with monocurve contact lenses. Of the 162 eyes classified as grade I and II, 51%, 30%, and 19% were fitted with adapted monocurve rigid gas-permeable contact lenses (RGPCL), bicurve lenses, and others lens types, respectively. Bicurve lenses were fitted in 52.1% and 62.2% of eyes classified as grade III and IV, respectively. Of the eyes classified as grade III and IV, monocurve and bicurve RGPCL were fitted in 26% and 55%, respectively. In eyes with oval keratoconus, 45%, 35%, and 20% were fitted with monocurve lenses, bicurve lenses, and other lens types, respectively. In eyes with round cones (nipple morphology), 55%, 30%, and 15% were fitted with bicurve lenses, monocurve lenses, and other lens types, respectively. Monocurve RGPCL were most frequently fitted in patients with mild to moderate keratoconus and oval cones morphology, while bicurve lenses were more frequently fitted in patients with severe and advanced keratoconus. This was probably because bicurve lenses are more appropriate for round cones due to increased corneal asphericity.

  5. Transepithelial Photorefractive Keratectomy with Crosslinking for Keratoconus

    PubMed Central

    Mukherjee, Achyut N; Selimis, Vasilis; Aslanides, Ioannis

    2013-01-01

    Purpose: To analyse visual, refractive and topographic outcomes of combining transepithelial photorefractive keratectomy (tPRK) with simultaneous corneal crosslinking for the visual rehabilitation of contact lens intolerant keratoconus patients. Methods: Patients with topographically significant keratoconus, limited corrected vision and intolerant of contact lenses were prospectively recruited, subject to ethical approval and consent. All patients underwent single step aspheric tPRK and sequential crosslinking. Preoperative vision, refraction, corneal topography and wavefront were assessed, with postoperative assessment at 1, 3, 6, and 12 months. Results: 22 eyes of 14 patients were included in the pilot study. Mean age was 32 years (SD 6.8, range 24 to 43). Mean preoperative unaided vision was 1.39 LogMAR (SD 0.5) best corrected 0.31 LogMAR (SD 0.2). Mean preoperative spherical equivalent was -2.74 Diopters (D) (SD 4.1 range -12.25 to +7.75), and mean cylinder -2.9 D (SD 1.2, range 0 to -5.5). Mean central corneal thickness was 461um (SD 29, range 411 to 516). Vision improved postoperatively; unaided 0.32 LogMAR (SD 0.4), best corrected 0.11 (SD 0.13) (P=<0.005). Mean postoperative cylinder was -1.4D (SD1.2), significantly reduced (p<0.005). Maximum keratometry (Kmax) was stable throughout postoperative follow up. (p<0.05). Conclusions: Non topographic transepithelial PRK with simultaneous crosslinking improves vision, and may offer an alternative to keratoplasty in contact lens intolerant keratoconus. Further comparative studies to topographic PRK techniques are indicated. PMID:24222809

  6. Current optometric practices and attitudes in keratoconus patient management.

    PubMed

    Ortiz-Toquero, Sara; Martin, Raul

    2017-08-01

    To compare the current optometric practices and attitudes in the management of keratoconus patients in the UK and Spain. An online survey (adapted to optometric practices) was distributed via a newsletter emailed by various professional organizations in the UK and Spain. Four hundred and sixty-four practitioners (126 in the UK; 338 in Spain) who prescribed gas permeable GP contact lenses (CLs) more than once per month (54.8% of UK practitioners and 28.1% of practitioners in Spain; p<0.01) responded to the questionnaire. A combination of multiple factors is considered necessary in the keratoconus detection (79.4% in the UK, 75% in Spain; p=0.68), and the use of classification criteria is considered relevant (67.5% in the UK, 70.7% in Spain; p=0.49). There is a high consensus on the consideration that GP CL fitting is more difficult in keratoconus (79.4% in the UK, 80.5% in Spain; p=0.79) requiring more diagnostic lenses (3.2±1.4 and 3.4±1.2 in the UK and Spain, respectively; p=0.72) than are necessary for healthy eyes. Using corneal topography is uncommon from both countries (38.1% in the UK, 59.8% in Spain; p<0.01), with a similar ophthalmologist referral pattern (at initial diagnosis, 50% in both the UK and Spain; p=1.00). Few cases of co-management with ophthalmologists were noted (no co-management reported by 60.3% in the UK and 72.8% in Spain, p=0.01). This study provides initial observations and evidence regarding keratoconus management by optometrists in the UK and Spain and shows similarity in the professional practices and attitudes of practitioners in these two countries. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Clinical Outcomes after Keraring Implantation for Keratoconus Management in Patients Older Than 40 Years: A Retrospective, Interventional, Cohort Study.

    PubMed

    Gatzioufas, Zisis; Khine, Aye; Elalfy, Mohamed; Guber, Ivo; McLintock, Cameron; Sabatino, Francesco; Hamada, Samer; Lake, Damian

    2018-06-01

    Intracorneal ring segment implantation is an effective and safe method of visual improvement in patients with keratoconus. The aim of our study was to evaluate the long-term clinical outcomes after Keraring implantation for keratoconus in patients older than 40 years. Eleven eyes from 11 patients with keratoconus who underwent femtosecond laser-assisted Keraring implantation for keratoconus were included in this retrospective study. The uncorrected visual acuity (UCVA), corrected visual acuity, keratometric readings, central corneal thickness and thinnest corneal pachymetry were evaluated preoperatively and 6 months after the Keraring implantation. UCVA, BCVA and keratometric readings improved at 6 months postoperatively. Our data showed significant keratometric amelioration and visual improvement after Keraring implantation for keratoconus in patients older than 40 years at 6 months postoperatively.

  8. Brittle cornea syndrome ZNF469 mutation carrier phenotype and segregation analysis of rare ZNF469 variants in familial keratoconus.

    PubMed

    Davidson, Alice E; Borasio, Edmondo; Liskova, Petra; Khan, Arif O; Hassan, Hala; Cheetham, Michael E; Plagnol, Vincent; Alkuraya, Fowzan S; Tuft, Stephen J; Hardcastle, Alison J

    2015-01-06

    Brittle cornea syndrome 1 (BCS1) is a rare recessive condition characterized by extreme thinning of the cornea and sclera, caused by mutations in ZNF469. Keratoconus is a relatively common disease characterized by progressive thinning and ectasia of the cornea. The etiology of keratoconus is complex and not yet understood, but rare ZNF469 variants have recently been associated with disease. We investigated the phenotype of BCS1 carriers with known pathogenic ZNF469 mutations, and recruited families in which aggregation of keratoconus was observed to establish if rare variants in ZNF469 segregated with disease. Patients and family members were recruited and underwent comprehensive anterior segment examination, including corneal topography. Blood samples were donated and genomic DNA was extracted. The coding sequence and splice sites of ZNF469 were PCR amplified and Sanger sequenced. Four carriers of three BCS1-associated ZNF469 loss-of-function mutations (p.[Glu1392Ter], p.[Gln1930Argfs*6], p.[Gln1930fs*133]) were examined and none had keratoconus. One carrier had partially penetrant features of BCS1, including joint hypermobility. ZNF469 sequencing in 11 keratoconus families identified 9 rare (minor allele frequency [MAF] ≤ 0.025) variants predicted to be potentially damaging. However, in each instance the rare variant(s) identified, including two previously reported as potentially keratoconus-associated, did not segregate with the disease. The presence of heterozygous loss-of-function alleles in the ZNF469 gene did not cause keratoconus in the individuals examined. None of the rare nonsynonymous ZNF469 variants identified in the familial cohort conferred a high risk of keratoconus; therefore, genetic variants contributing to disease pathogenesis in these 11 families remain to be identified. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  9. Association of fluorescein anterior corneal mosaic and corneal K-structures by in vivo laser confocal microscopy in patients with keratoconus.

    PubMed

    Kobayashi, Akira; Yokogawa, Hideaki; Mori, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa

    2017-01-01

    To report the in vivo laser confocal microscopy findings of corneas with keratoconus, with special attention to abnormality of Bowman's layer and sub-Bowman's fibrous structures (Kobayashi-structures [K-structures]). Sixteen keratoconic eyes in 8 consecutive patients with keratoconus (4 males, 4 females, mean age, 41.1 years) were included in this study. Slit-lamp biomicroscopic photos were taken with or without fluorescein staining. The existence of anterior corneal mosaic (ACM) after eyelid rubbing under fluorescein staining was documented. In vivo laser confocal microscopic examinations were performed for all patients in both the central cone and the peripheral cornea to examine the existence of K-structures. According to the Amsler-Krumeich scale, the eyes were graded as follows: stage 1 (n=3), stage 2 (n=1), stage 3 (n=1), and stage 4 (n=11). ACM was observed in 7 eyes (61.1%) in the cone area and 16 eyes (100%) in the peripheral cornea among all keratoconic eyes enrolled in this study. In addition, K-structures were observed in the 7 eyes (61.1%) and 16 eyes (100%) in the peripheral cornea among all keratoconic eyes. The presence of the K-structures was completely matched (100%) with the presence of ACM in both the central cone and the peripheral cornea. In 11 eyes with stage 4 keratoconus, ACM and K-structure was absent in 9 eyes (81.8%) in the cone area. On the contrary, in 5 eyes with mild-to-moderate keratoconus (grade 1 to 3), ACM and K-structure was present in all eyes (100%) in the cone area. The absent ratio of ACM and K-structures in the cone area was significantly higher in stage 4 severe keratoconus compared to mild-to-moderate keratoconus (grade 1 to 3) (Fisher, P =0.005). The existence of ACM and K-structures in both the central cone and the peripheral cornea showed perfect accord in patients with keratoconus, indicating a strong association of ACM and K-structures in patients with keratoconus. With the progress of the keratoconus, it seemed that

  10. Association of fluorescein anterior corneal mosaic and corneal K-structures by in vivo laser confocal microscopy in patients with keratoconus

    PubMed Central

    Kobayashi, Akira; Yokogawa, Hideaki; Mori, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa

    2017-01-01

    Objective To report the in vivo laser confocal microscopy findings of corneas with keratoconus, with special attention to abnormality of Bowman’s layer and sub-Bowman’s fibrous structures (Kobayashi-structures [K-structures]). Methods Sixteen keratoconic eyes in 8 consecutive patients with keratoconus (4 males, 4 females, mean age, 41.1 years) were included in this study. Slit-lamp biomicroscopic photos were taken with or without fluorescein staining. The existence of anterior corneal mosaic (ACM) after eyelid rubbing under fluorescein staining was documented. In vivo laser confocal microscopic examinations were performed for all patients in both the central cone and the peripheral cornea to examine the existence of K-structures. Results According to the Amsler–Krumeich scale, the eyes were graded as follows: stage 1 (n=3), stage 2 (n=1), stage 3 (n=1), and stage 4 (n=11). ACM was observed in 7 eyes (61.1%) in the cone area and 16 eyes (100%) in the peripheral cornea among all keratoconic eyes enrolled in this study. In addition, K-structures were observed in the 7 eyes (61.1%) and 16 eyes (100%) in the peripheral cornea among all keratoconic eyes. The presence of the K-structures was completely matched (100%) with the presence of ACM in both the central cone and the peripheral cornea. In 11 eyes with stage 4 keratoconus, ACM and K-structure was absent in 9 eyes (81.8%) in the cone area. On the contrary, in 5 eyes with mild-to-moderate keratoconus (grade 1 to 3), ACM and K-structure was present in all eyes (100%) in the cone area. The absent ratio of ACM and K-structures in the cone area was significantly higher in stage 4 severe keratoconus compared to mild-to-moderate keratoconus (grade 1 to 3) (Fisher, P=0.005). Conclusion The existence of ACM and K-structures in both the central cone and the peripheral cornea showed perfect accord in patients with keratoconus, indicating a strong association of ACM and K-structures in patients with keratoconus. With the

  11. Corneal Cross-Linking for the Treatment of Keratoconus in a Patient with Ipsilateral Myelinated Retinal Nerve Fiber Layer

    PubMed Central

    Leozappa, M.; Ciani, S.; Ferrari, T. Micelli

    2011-01-01

    Keratoconus associated with myelinated retinal nerve fibers is not frequent and the relationship between the two pathologies is difficult to explain, therefore studies and further investigation are required. The etiology of each condition may suggest the role of genetic factors. Follow-up is important to evaluate the progression of keratoconus and myelination. Here we describe the unusual coexistence of keratoconus and ipsilateral myelinated retinal nerve fiber layer and, for the first time, the corneal cross-linking treatment in this condition. PMID:21475609

  12. Involvement of Sp1 elements in the promoter activity of genes affected in keratoconus.

    PubMed

    Maruyama, Y; Wang, X; Li, Y; Sugar, J; Yue, B Y

    2001-08-01

    Keratoconus is a progressive disease that thins and scars the corneal stroma. In keratoconus corneas, levels of degradative enzymes, including lysosomal acid phosphatase (LAP) and cathepsin B, are elevated, and those of the inhibitors alpha1-proteinase inhibitor (alpha 1-PI) and alpha 2-macroglobulin (alpha 2-M) are reduced, especially in the epithelial layer. An increased expression of the transcription factor Sp1 was also demonstrated. The role of Sp1 in regulation of the genes affected in keratoconus was examined in this study. DNA segments, containing 5'-flanking promoter sequences of the alpha 1-PI, LAP, cathepsin B, and alpha 2-M genes were ligated into the secreted alkaline phosphatase (SEAP) reporter gene vector. These constructs, along with the pSV beta-galactosidase control vector, were transfected into cultured human corneal epithelial and stromal cells and skin fibroblasts. Cotransfection with the Sp1 expression vector was performed in parallel. SEAP and beta-galactosidase enzyme activities were assayed. In corneal epithelial cells, as in stromal cells, alpha 1-PI promoter activity was suppressed by cotransfection of pPacSp1. The LAP, cathepsin B, and alpha 2-M promoters were functional in corneal cells, whereas activities of these promoters were much lower in skin fibroblasts. Cotransfection experiments indicated that the up- or downregulation of LAP, cathepsin B, and alpha 2-M observed in keratoconus-affected corneas was not mediated by Sp1. These results support the theory that the corneal epithelium, along with the stroma, is involved in keratoconus. An upstream role of Sp1 is indicated and the Sp1-mediated downregulation of the alpha 1-PI gene may be a key event in the disease development.

  13. [Freiburg keratoconus registry : Example of application of smart data for clinical research and inititial results].

    PubMed

    Lang, S J; Böhringer, D; Reinhard, T

    2016-06-01

    Keratoconus is a progressive corneal disease with thinning and scarring of the cornea. Diagnostic and treatment options are usually evaluated in large prospective or retrospective trials. Big data and smart data provide the possibility to analyze routine data for clinical research. In this article we report the generation of a monocentric keratoconus registry by means of computerized data analysis of routine data. This demonstrates the potential of clinical research by means of routine data. A "clinical data warehouse" was created from all available routine electronic data. At the time of first presentation, each eye was classified into one out of four categories: suspected, early disease, late disease and status postkeratoplasty. Through integration of multiple data sources the clinical course for each patient was documented in the registry. A total of 3681 eyes from 1841 patients were included. The median follow-up time was 0.54 years. Patient age was higher in the groups with more severe stages of keratoconus, the proportion of female patients was higher in the group of suspected keratoconus and patient age and male to female ratios showed statistically significant differences between the groups (p < 0.001). We were able to create a "clinical data warehouse" by linking multiple data sources and normalizing the data. With this tool we established a novel, monocentric keratoconus registry. Only the grading of disease severity and the exclusion of false positive results were carried out manually. In our opinion establishing a structured clinical data warehouse has a huge potential for clinical and retrospective studies and proves the value of the Smart Data concept.

  14. Combining primary and piggyback intraocular lenses to treat extreme myopic astigmatism in stable keratoconus following cataract surgery.

    PubMed

    Goh, Yi Wei; Misra, Stuti; Patel, Dipika V; McGhee, Charles N J

    2013-03-01

    The majority of those with keratoconus can maximise visual acuity with spectacle or contact lens correction as they age; however, as subjects enter their sixties, cataracts may supervene and contact lens tolerance diminishes with consequent reduction in visual acuity. Following cataract extraction, the complex refractive error associated with keratoconus may not be readily corrected by an intraocular lens alone. This report highlights the planned implantation of a primary posterior chamber toric intraocular lens with a secondary piggyback, sulcus-based, intraocular lens in advanced but stable keratoconus with extreme myopic astigmatism and cataract. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  15. Bilateral ring-shaped intrastromal opacities after corneal cross-linking for keratoconus.

    PubMed

    Camesasca, Fabrizio I; Vinciguerra, Paolo; Seiler, Theo

    2011-12-01

    To report a case of bilateral, ring-shaped, intrastromal corneal opacities after corneal cross-linking (CXL) for progressive keratoconus. A 21-year-old man with bilateral, progressive keratoconus underwent CXL with riboflavin 0.1% and ultraviolet A (UVA) light in the right eye and, 6 months later, in the left eye. One day after CXL, the right eye showed a sharply demarcated white ring in the corneal periphery. The ring involved the superficial stroma at 2 mm from the limbus, extended from 1 to 11 o'clock, and was 1.5-mm wide. Corneal topography showed marked central flattening. Six months after treatment, a residual, faint, ring-shaped opacity remained, with a decrease in corneal ectasia. Cross-linking was then performed in the left eye. Different ultraviolet devices were used in the two eyes. On postoperative day 1, the left eye also showed a white ring of stromal opacity. Scheimpflug imaging showed corneal stromal contraction in the zone of whitening. At final examination, >1 year after surgery, corrected visual acuity was 0.00 logMAR with cylinder of 2.00 diopters in both eyes. The bilateral intrastromal corneal changes were innocuous in the long-term, with preservation of good visual acuity and successful stabilization of progressive keratoconus.

  16. Arginase activity, urea, and hydroxyproline concentration are reduced in keratoconus keratocytes.

    PubMed

    Stachon, Tanja; Kolev, Krasimir; Flaskó, Zsuzsa; Seitz, Berthold; Langenbucher, Achim; Szentmáry, Nóra

    2017-01-01

    Keratoconus (KC) is a disease characterized by thinning and deformation of the cornea, but its etiology remains unknown. Seventy percent of the corneal stroma consists of collagen, which is composed of three intertwined polypeptide chains with glycine-hydroxyproline-proline repeats along their sequence. Arginase is a cytoplasmatic enzyme and catalyzes the conversion of arginine to urea and ornithine, which serves as a precursor for the endogenous synthesis of proline and hydroxyproline. The purpose of this study was to analyze arginase activity, as well as collagen and urea formation in normal and KC-keratocytes and to determine the impact of urea on keratocyte viability and proliferation in vitro. Primary human keratocytes were isolated by digestion in collagenase (1.0 mg/mL) from surgically removed corneas of eight keratoconus patients and eight normal human corneal buttons and cultured in DMEM/Ham's F12 medium supplemented with 5 % fetal calf serum. Arginase activity and urea concentration were measured in cell-lysates, hydroxyproline concentration in supernatant of cultured keratocytes using colorimetric assay. Cell viability and cell proliferation of cultured keratocytes were assessed after treatment with urea at concentrations up to10 mM for 24 h using assays for metabolic activity and DNA replication. Arginase activity and urea concentration in KC-keratocytes decreased by about 50 % compared to normal keratocytes (p = 0.003 and p = 0.008). Hydroxyproline synthesized by cultured KC-keratocytes was also approximately 50 % less compared to normal keratocytes (p = 0.02) and this difference decreased following treatment with 5.0 or 10.0 mM urea (p = 0.02; 0.03), without any change in cell viability (p > 0.09). However, the urea treatment increased modestly (by 20 %) the proliferation rate of KC-keratocytes (p = 0.04; 0.04; 0.04), without any effect on normal cultured keratocytes (p > 0.09). We identified suppressed arginase

  17. Dr John Nottingham's 1854 Landmark Treatise on Conical Cornea Considered in the Context of the Current Knowledge of Keratoconus.

    PubMed

    Gokul, Akilesh; Patel, Dipika V; McGhee, Charles N J

    2016-05-01

    John Nottingham has been widely credited with the first accurate description of keratoconus in his treatise on conical cornea, published in 1854. Contained within the 270-page treatise are accounts and theories of keratoconus postulated by authors such as Scarpa, von Carion, von Ammon, and Mackenzie, synthesized by Nottingham in a treatise containing his own original observations. Nottingham's work delves deeply into keratoconus, with coverage reminiscent of a modern review, albeit in a far less succinct manner. He extensively describes the epidemiology, clinical presentation, underlying cause, and treatment of keratoconus. However, the concepts put forth are limited largely by the contemporary lack of understanding of the underlying anatomy and physiology of the eye, and the observations, by technological limitations. He postulates a similar treatment algorithm to that used today; optical devices being the management option of choice in the mild stages with surgery being a last resort. None of the surgical methods discussed are used in the modern era, but he does make reference to the possible efficacy of corneal transplantation. Nottingham's treatise was published over 160 years ago, yet his ideas and observations are surprisingly accurate. It is very possible that he was the first person to publish an accurate, comprehensive description of keratoconus.

  18. Keratoconus corneal architecture after riboflavin/ultraviolet A cross-linking: Ultrastructural studies

    PubMed Central

    Almubrad, Turki; Paladini, Iacopo; Mencucci, Rita

    2013-01-01

    Purpose Study to investigate the effects of collagen cross-linking on the ultrastructural organization of the corneal stroma in the human keratoconus cornea (KC). Methods Three normal, three keratoconus (KC1, KC2, KC3), and three cross-linked keratoconus (CXL1, CXL2, CXL3) corneas were analyzed. The KC corneas were treated with a riboflavin-ultraviolet A (UVA) treatment (CXL) method described by Wollensak et al. Penetrating keratoplasty (PKP) was performed 6 months after treatment. All samples were processed for electron microscopy. Results The riboflavin-UVA-treated CXL corneal stroma showed interlacing lamellae in the anterior stroma followed by well-organized parallel running lamellae. The lamellae contained uniformly distributed collagen fibrils (CFs) decorated with normal proteoglycans (PGs). The CF diameter and interfibrillar spacing in the CXL cornea were significantly increased compared to those in the KC cornea. The PG area in the CXL corneas were significantly smaller than the PGs in the KC cornea. The epithelium and Bowman’s layer were also normal. On rare occasions, a thick basement membrane and collagenous pannus were also observed. Conclusions Corneal cross-linking leads to modifications of the cornea stroma. The KC corneal structure showed a modification in the CF diameter, interfibrillar spacing, and PG area. This resulted in a more uniform distribution of collagen fibrils, a key feature for corneal transparency. PMID:23878503

  19. The value-based medicine comparative effectiveness and cost-effectiveness of penetrating keratoplasty for keratoconus.

    PubMed

    Roe, Richard H; Lass, Jonathan H; Brown, Gary C; Brown, Melissa M

    2008-10-01

    To perform a base case, comparative effectiveness, and cost-effectiveness (cost-utility) analysis of penetrating keratoplasty for patients with severe keratoconus. Visual acuity data were obtained from a large, retrospective multicenter study in which patients with keratoconus with less than 20/40 best corrected visual acuity and/or the inability to wear contact lenses underwent penetrating keratoplasty, with an average follow-up of 2.1 years. The results were combined with other retrospective studies investigating complication rates of penetrating keratoplasty. The data were then incorporated into a cost-utility model using patient preference-based, time trade-off utilities, computer-based decision analysis, and a net present value model to account for the time value of outcomes and money. The comparative effectiveness of the intervention is expressed in quality-of-life gain and QALYs (quality-adjusted life-years), and the cost-effectiveness results are expressed in the outcome of $/QALY (dollars spent per QALY). Penetrating keratoplasty in 1 eye for patients with severe keratoconus results in a comparative effectiveness (value gain) of 16.5% improvement in quality of life every day over the 44-year life expectancy of the average patient with severe keratoconus. Discounting the total value gain of 5.36 QALYs at a 3% annual discount rate yields 3.05 QALYs gained. The incremental cost for penetrating keratoplasty, including all complications, is $5934 ($5913 discounted at 3% per year). Thus, the incremental cost-utility (discounted at 3% annually) for this intervention is $5913/3.05 QALYs = $1942/QALY. If both eyes undergo corneal transplant, the total discounted value gain is 30% and the overall cost-utility is $2003. Surgery on the second eye confers a total discounted value gain of 2.5 QALYs, yielding a quality-of-life gain of 11.6% and a discounted cost-utility of $2238/QALY. Penetrating keratoplasty for patients with severe keratoconus seems to be a

  20. Stromal demarcation line induced by corneal cross-linking in eyes with keratoconus and nonkeratoconic asymmetric topography.

    PubMed

    Malta, João B N; Renesto, Adimara C; Moscovici, Bernardo K; Soong, H K; Campos, Mauro

    2015-02-01

    To evaluate stromal demarcation lines following corneal cross-linking (CXL) using anterior segment optical coherence tomography in patients with keratoconus and nonkeratoconic asymmetric topography. Fifth-nine eyes of 59 patients were enrolled in a retrospective comparative case series, of which 19 eyes had keratoconus and 40 eyes had asymmetric topography. Eyes with asymmetric topography were treated in preparation for photorefractive keratectomy. One month after CXL, a stromal demarcation line was evaluated at 5 standardized corneal points using anterior segment optical coherence tomography. Mean stromal demarcation line depths were measured at 5 points on the cornea, namely, centrally, 3.0 mm temporally, 1.5 mm temporally, 3.0 mm nasally, and 1.5 mm nasally. For the keratoconus group, the values were 178 ± 47, 123 ± 15, 152 ± 47, 125 ± 23, and 160 ± 43 μm, respectively. For the asymmetric corneal topography group (without keratoconus), they were 305 ± 64, 235 ± 57, 294 ± 50, 214 ± 54, and 285 ± 58 μm, respectively. There was no correlation between central corneal pachymetry and stromal demarcation line depth in all 5 measured corneal points in both groups. CXL treatment profiles are similar in keratoconic and nonkeratoconic eyes with asymmetric topography.

  1. Simultaneous topography-guided PRK followed by corneal collagen cross-linking for keratoconus.

    PubMed

    Kymionis, George D; Kontadakis, Georgios A; Kounis, George A; Portaliou, Dimitra M; Karavitaki, Alexandra E; Magarakis, Michael; Yoo, Sonia; Pallikaris, Ioannis G

    2009-09-01

    To present the results after simultaneous photorefractive keratectomy (PRK) followed by corneal collagen cross-linking (CXL) for progressive keratoconus. Twelve patients (14 eyes) with progressive keratoconus were prospectively treated with customized topography-guided PRK with the Pulzar Z1 (wavelength 213 nm, CustomVis) immediately followed by corneal collagen CXL with the use of riboflavin and ultraviolet A irradiation. Mean follow-up was 10.69+/-5.95 months (range: 3 to 16 months). Mean preoperative spherical equivalent refraction (SE) was -3.03+/-3.23 diopters (D) and defocus was 4.67+/-3.29 D; at last follow-up SE and defocus were statistically significantly reduced to -1.29+/-2.05 D and 3.04+/-2.53 D, respectively (P<.01). Preoperative mean (logMAR) uncorrected visual acuity was 0.99+/-0.81 and best spectacle-corrected visual acuity was 0.21+/-0.19, which improved postoperatively to 0.16+/-0.15 and 0.11+/-0.15, respectively. The mean steepest keratometry was reduced from 48.20+/-3.40 D preoperatively to 45.13+/-1.80 D at last follow-up. Simultaneous PRK followed by CXL seems to be a promising treatment capable of offering functional vision in patients with keratoconus. Copyright 2009, SLACK Incorporated.

  2. Fixed dilated pupil (Urrets-Zavalia syndrome) after air/gas injection after deep lamellar keratoplasty for keratoconus.

    PubMed

    Maurino, Vincenzo; Allan, Bruce D S; Stevens, Julian D; Tuft, Stephen J

    2002-02-01

    To describe three cases of fixed dilated pupil and presumed iris ischemia (Urrets-Zavalia syndrome) after anterior chamber air/gas injection after deep lamellar keratoplasty for keratoconus. Interventional case series. Three eyes of three patients with keratoconus underwent deep lamellar keratoplasty and intraoperative or postoperative injection of air/gas in the anterior chamber to appose the host-donor lamellar graft interface. Urrets-Zavalia syndrome was diagnosed on clinical grounds in three cases and was associated with the Descemet membrane microperforation intraoperatively and introduction of air/gas into the anterior chamber intraoperatively or postoperatively. A fixed dilated pupil is an uncommon complication of penetrating keratoplasty for keratoconus that can also develop after deep lamellar keratoplasty. Leaving an air or gas bubble in the anterior chamber of a phakic eye after deep lamellar keratoplasty is a risk factor and should therefore be avoided.

  3. Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes.

    PubMed

    Choi, Young; Eom, Youngsub; Song, Jong Suk; Kim, Hyo Myung

    2018-05-15

    To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 CD, respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. © 2018 The Korean Ophthalmological Society.

  4. Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes

    PubMed Central

    Choi, Young; Song, Jong Suk; Kim, Hyo Myung

    2018-01-01

    Purpose To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Methods Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. Results The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 cylinder diopters [CD], respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Conclusions Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. PMID:29770640

  5. Bilateral Keratoconus Induced by Secondary Hypothyroidism After Radioactive Iodine Therapy.

    PubMed

    Lee, Ramon; Hafezi, Farhad; Randleman, J Bradley

    2018-05-01

    To present a case of new-onset, bilateral, rapidly progressive keratoconus induced by secondary hypothyroidism after radioactive iodine therapy during the sixth decade of life that was successfully treated with corneal cross-linking. Case report and literature review. A 53-year-old woman with no ocular complaints but with a history of Graves' disease and thyrotoxicosis was treated with radioactive iodine therapy and oral levothyroxine for secondary acquired hypothyroidism 3 years prior. Initially, uncorrected distance visual acuity (UDVA) was 20/40 and corrected distance visual acuity (CDVA) was 20/25 in both eyes. Over the following 3 years, the patient developed worsening UDVA and CDVA, with increasing manifest astigmatism of greater than 7.00 diopters (D) in the right eye and 4.75 D in the left eye, with corneal thinning and focal steepening and was diagnosed as having bilateral progressive keratoconus. The patient underwent sequential corneal cross-linking with resultant postoperative CDVA of 20/20 and reduced maximum keratometry and manifest astigmatism in both eyes. The patient's thyroid levels were within normal limits throughout the clinical course. This case provides evidence of the relationship between keratoconus development and thyroid gland dysfunction. The pathophysiology of this relationship has yet to be completely elucidated, but elevated levels of thyroxine in the aqueous humor and tear film and thyroxine receptors in the cornea likely play a role. Screening topographies for patients with thyroid gland dysfunction may be of value for these higher risk patients. [J Refract Surg. 2018;34(5):351-353.]. Copyright 2018, SLACK Incorporated.

  6. Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis.

    PubMed

    Fukuda, Shinichi; Beheregaray, Simone; Hoshi, Sujin; Yamanari, Masahiro; Lim, Yiheng; Hiraoka, Takahiro; Yasuno, Yoshiaki; Oshika, Tetsuro

    2013-12-01

    To evaluate the ability of parameters measured by three-dimensional (3D) corneal and anterior segment optical coherence tomography (CAS-OCT) and a rotating Scheimpflug camera combined with a Placido topography system (Scheimpflug camera with topography) to discriminate between normal eyes and forme fruste keratoconus. Forty-eight eyes of 48 patients with keratoconus, 25 eyes of 25 patients with forme fruste keratoconus and 128 eyes of 128 normal subjects were evaluated. Anterior and posterior keratometric parameters (steep K, flat K, average K), elevation, topographic parameters, regular and irregular astigmatism (spherical, asymmetry, regular and higher-order astigmatism) and five pachymetric parameters (minimum, minimum-median, inferior-superior, inferotemporal-superonasal, vertical thinnest location of the cornea) were measured using 3D CAS-OCT and a Scheimpflug camera with topography. The area under the receiver operating curve (AUROC) was calculated to assess the discrimination ability. Compatibility and repeatability of both devices were evaluated. Posterior surface elevation showed higher AUROC values in discrimination analysis of forme fruste keratoconus using both devices. Both instruments showed significant linear correlations (p<0.05, Pearson's correlation coefficient) and good repeatability (ICCs: 0.885-0.999) for normal and forme fruste keratoconus. Posterior elevation was the best discrimination parameter for forme fruste keratoconus. Both instruments presented good correlation and repeatability for this condition.

  7. Association of -31T>C and -511 C>T polymorphisms in the interleukin 1 beta (IL1B) promoter in Korean keratoconus patients.

    PubMed

    Kim, So-Hee; Mok, Jee-Won; Kim, Hyun-Seok; Joo, C K

    2008-01-01

    To investigate the genetic association between unrelated Korean keratoconus patients and interleukin 1 alpha (IL1A), interleukin 1 beta (IL1B), and IL1 receptor antagonist (IL1RN) gene polymorphisms. We investigated the association between IL1A (rs1800587, rs2071376, and rs17561), IL1B (rs1143627, rs16944, rs1143634, and rs1143633), and IL1RN (rs419598, rs423904, rs424078, and rs315952, variable number tandem repeat [VNTR]) polymorphisms in 100 unrelated Korean keratoconus patients. One hundred control individuals without any corneal disease were selected from the general population. Polymerase chain reaction (PCR) - restriction fragment length polymorphism (RFLP) analysis and direct sequencing were used to screen for genetic variations in the IL1 gene cluster. Haplotypes for the IL1 gene cluster were constructed using Haploview version 4.0. We analyzed a total of 12 polymorphic sites in the IL1 gene cluster. Among them, the -511 (rs16944) and -31 (rs1143627) positions in the promoter region of IL1B were significantly different between patient and control groups. The C allele of rs16944 (-511C>T, p=0.022, odds ratio of risk [OR]=1.46, 95% confidence intervals [CI] 0.94<2.27) and the T allele of rs1143627 (-31T>C, p=0.025, OR=1.43, 95% CI 0.92<2.22) were associated with a significantly increased risk of keratoconus in Korean patients. Linkage of the two alleles, -31*C and -511*T, was associated with an increased risk for keratoconus with OR=2.38 (p=0.012, 95% CI=1.116-5.046). The *C/*A genotype of rs2071376 in IL1A intron 6 was significantly different between the keratoconus patients and control subjects (p=0.034, OR=0.59, 95% CI 0.32<1.11). Other polymorphisms did not show an association with keratoconus risk. This is the first report of IL1 gene cluster mutation screening in Korean keratoconus patients. Significant differences in allelic frequency of IL1B between keratoconus patients and the control group suggest that IL1B polymorphisms may play a role in the

  8. Comparison of stromal corneal nerves between normal and keratoconus patients using confocal microscopy.

    PubMed

    Ramírez Fernández, M; Hernández Quintela, E; Naranjo Tackman, R

    2014-08-01

    To evaluate the differences in stromal corneal nerves between normal patients and keratoconus patients. A total of 140 eyes of 70 normal patients (group A) and 122 eyes of 87 keratoconus patients (group B) were examined with the confocal microscope, with a central scan of the total corneal thickness being taken. The morphology and thickness of the corneal stromal nerves were evaluated by using the Navis v. 3.5.0. software. Nerve thickness was obtained from the mean between the widest and the narrowest portions of each stromal nerve. Corneal stromal nerves were observed as irregular linear hyper-reflective structures with wide and narrow portions in all cases. Mean corneal stromal nerves thickness in group A was 5.7±1.7 (range from 3.3 to 10.4 μ), mean corneal stromal nerves thickness in group B was 7.2±1.9 (range from 3.5 to 12.0 μ). There was a statistical significant difference (P<.05) in stromal corneal nerves thickness between group A and group B. Stromal corneal nerves morphology was similar in both groups, but stromal nerves were thicker in keratoconus patients. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  9. Femtosecond laser-assisted deep anterior lamellar keratoplasty with big-bubble technique for keratoconus.

    PubMed

    Lu, Yan; Chen, Xiangfei; Yang, Liping; Xue, Chunyan; Huang, Zhenping

    2016-09-01

    The purpose of this study was to evaluate the clinical results after deep anterior lamellar keratoplasty (DALK) assisted by the femtosecond laser with big-bubble technique for keratoconus. A case series of 22 eyes in 19 patients with keratoconus was enrolled in the study. The 500-kHz VisuMax femtosecond laser (Carl Zeiss Meditec AG, Jena, Germany) was used to create a vertical side cut on donor and recipient corneas. Intraoperative and postoperative complications, uncorrected visual acuity, best-corrected visual acuity, corneal curvature, and central corneal thickness were evaluated in all patients. Big-bubble and naked Descemet's membrane (DM) were successfully achieved in twenty eyes (90.9%). Intraoperative macroperforation of DM occurred in two cases and converted to full-thickness keratoplasty. The mean follow-up time was 18.8 ± 5.3 months. The best-corrected visual acuity was increased from 0.3 to 1.0, mean corneal curvature was 43.0 ± 2.3D, and mean central corneal thickness was 508.9 ± 60.1 μm (range, from 430 to 600 μm) postoperatively. Our results indicate that femtosecond laser-assisted DALK with big-bubble technique is an accurate, safe, and effective method to treat the patients with keratoconus.

  10. The Effect of Corneal Epithelium on Corneal Curvature in Patients with Keratoconus.

    PubMed

    Akcay, Emine Kalkan; Uysal, Betul Seher; Sarac, Ozge; Ugurlu, Nagehan; Yulek, Fatma; Cagil, Nurullah; Aslan, Nabi

    2015-01-01

    To investigate the effects of corneal epithelium on corneal curvature in patients with keratoconus. This is a prospective, nonrandomized study. Fifty-nine eyes of 47 patients diagnosed as keratoconus and for whom corneal collagen crosslinking (CXL) was recruited in this study. This study is a single-center clinical trial. Pregnancy, lactation, connective tissue disease, corneal thickness below 350 μm, severe dry eyes, or scar of corneal surgery were exclusion criteria. Before and during CXL procedure after removing the corneal epithelium, maximum values of corneal apical curvature, simulated keratometry 1 (Sim-K1), simulated keratometry 2 (Sim-K2), temporal and inferior curvature values, all of which are 1.5 mm from the corneal center, were calculated. These values before and after removal of epithelium were compared statistically. Mean age of patients was 23.30 ± 5.5 (12-38) years. Twenty-eight (59%) were male while 19 (41%) were female. Mean values measured before and after removing the corneal epithelium were: apical curvature; 59.19 ± 7.2 (47.06-82.40) diopter (D) and 61.70 ± 8.8 (49.19-92.66) D (p = 0.001), SimK1; 47.57 ± 4.3 (39.14-64.57) D and 48.23 ± 4.3 (41.89-66.70) D (p = 0.001), SimK2; 52.04 ± 5.3 (43.56-69.34) D and 53.34 ± 5.6 (43.73-70.89) D (p = 0.001), inferior curvature; 53,85 ± 5.2 (43.47-76.56) D and 55.05 ± 5.8 (44.56-81.93) D (p = 0.002), temporal curvature 49.49 ± 5.1 (41.50-71.03) D and 51.53 ± 5.4 (41.58-73.34) D (p = 0.001), respectively. In keratoconus patients during CXL treatment, after removing the corneal epithelium, more steepness is detected in the curvature of the steeper area of the cornea. When evaluating patients with keratoconus, the masking effect of corneal epithelium on values of curvature should be taken into consideration.

  11. Multifocal Choroiditis with Retinal Vasculitis, Optic Neuropathy, and Keratoconus in a Young Saudi Male.

    PubMed

    Dhafiri, Yousef; Al Rubaie, Khalid; Kirat, Omar; May, William N; Nguyen, Quan D; Kozak, Igor

    2017-01-01

    The purpose of this study is to describe an association of unilateral multifocal choroiditis (MFC), retinal vasculitis, optic neuropathy, and bilateral keratoconus in a young Saudi male. A 27-year-old male patient with stable bilateral keratoconus presented with a painless vision loss in his left eye. Ophthalmic examinations revealed multiple foci of idiopathic chorioretinitis, retinal vasculitis, and mild optic disc leakage on fluorescein angiography, all of which resolved on systemic therapy with mycophenolate mofetil and prednisone after 3 months. Systemic medication was stopped after 8 months. One year after presentation, patient's visual acuity has improved and remained stable. Systemic immunomodulatory therapy can be effective in managing and leading to resolution of MFC, retinal vasculitis, and optic disc leak in young patients.

  12. Correlation between visual function and refractive, topographic, pachymetric and aberrometric data in eyes with keratoconus

    PubMed Central

    Bayraktar Bilen, Neslihan; Hepsen, Ibrahim F.; Arce, Carlos G.

    2016-01-01

    AIM To analyze the relationship between two visual functions and refractive, topographic, pachymetric and aberrometric indicators in eyes with keratoconus. METHODS Corrected distance visual acuity (CDVA), and letter contrast sensitivity (CS) were correlated with refraction, corneal topography, pachymetry, and total corneal wavefront data prospectively in 71 eyes with keratoconus. The topographic indices assessed were simulated keratometry for the flattest and steepest meridians (SimK1 and SimK2), posterior steeper K (Ks), elevation value in best-fit sphere (BFS) maps, squared eccentricity (Є2), aspheric asymmetric index (AAI), pachymetry, thickness progression index (TPI), the amount of pachymetric decentralization (APD), and GalileiTM-keratoconus indices. RESULTS The mean CDVA (expressed as logMAR) were 0.25±0.21. The mean CS was 1.25±0.46. The spherical refraction correlated well with CDVA (r=-0.526, P<0.001). From topographic indices, SRI correlated with CS (r=-0.695), and IAI with CS (r=-0.672) (P<0.001 for all). Root mean square (RMS) was 4.3±1.81 µm, spherical aberration (SA) was -0.4±0.67 µm, vertical and horizontal coma were -2.1±1.47 and -0.4±0.72 µm. All wavefront data (except horizontal coma), AAI, Є2 and maximum BFS correlated significantly with the visual function (P≤0.001 for all). CONCLUSION In this study, CS is more affected than CDVA as a visual function. The quantity and quality of vision is significantly correlated with well-known and new topographic indices. There is not a significant correlation between visual function and pachymetric parameters. The significantly correlated indices can be used in staging keratoconus and to follow the outcome of a treatment. PMID:27588266

  13. Laser Vision Correction with Q Factor Modification for Keratoconus Management.

    PubMed

    Pahuja, Natasha Kishore; Shetty, Rohit; Sinha Roy, Abhijit; Thakkar, Maithil Mukesh; Jayadev, Chaitra; Nuijts, Rudy Mma; Nagaraja, Harsha

    2017-04-01

    To evaluate the outcomes of corneal laser ablation with Q factor modification for vision correction in patients with progressive keratoconus. In this prospective study, 50 eyes of 50 patients were divided into two groups based on Q factor (>-1 in Group I and ≤-1 in Group II). All patients underwent a detailed ophthalmic examination including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), subjective acceptance and corneal topography using the Pentacam. The topolyzer was used to measure the corneal asphericity (Q). Ablation was performed based on the preoperative Q values and thinnest pachymetry to obtain a target of near normal Q. This was followed by corneal collagen crosslinking to stabilize the progression. Statistically significant improvement (p ≤ 0.05) was noticed in refractive, topographic, and Q values posttreatment in both groups. The improvement in higher-order aberrations and total aberrations were statistically significant in both groups; however, the spherical aberration showed statistically significant improvement only in Group II. Ablation based on the preoperative Q and pachymetry for a near normal postoperative Q value appears to be an effective method to improve the visual acuity and quality in patients with keratoconus.

  14. Corneal Collagen Cross-Linking in the Management of Keratoconus in Canada: A Cost-Effectiveness Analysis.

    PubMed

    Leung, Victoria C; Pechlivanoglou, Petros; Chew, Hall F; Hatch, Wendy

    2017-08-01

    To use patient-level microsimulation models to evaluate the comparative cost-effectiveness of early corneal cross-linking (CXL) and conventional management with penetrating keratoplasty (PKP) when indicated in managing keratoconus in Canada. Cost-utility analysis using individual-based, state-transition microsimulation models. Simulated cohorts of 100 000 individuals with keratoconus who entered each treatment arm at 25 years of age. Fellow eyes were modeled separately. Simulated individuals lived up to a maximum of 110 years. We developed 2 state-transition microsimulation models to reflect the natural history of keratoconus progression and the impact of conventional management with PKP versus CXL. We collected data from the published literature to inform model parameters. We used realistic parameters that maximized the potential costs and complications of CXL, while minimizing those associated with PKP. In each treatment arm, we allowed simulated individuals to move through health states in monthly cycles from diagnosis until death. For each treatment strategy, we calculated the total cost and number of quality-adjusted life years (QALYs) gained. Costs were measured in Canadian dollars. Costs and QALYs were discounted at 5%, converting future costs and QALYs into present values. We used an incremental cost-effectiveness ratio (ICER = difference in lifetime costs/difference in lifetime health outcomes) to compare the cost-effectiveness of CXL versus conventional management with PKP. Lifetime costs and QALYs for CXL were estimated to be Can$5530 (Can$4512, discounted) and 50.12 QALYs (16.42 QALYs, discounted). Lifetime costs and QALYs for conventional management with PKP were Can$2675 (Can$1508, discounted) and 48.93 QALYs (16.09 QALYs, discounted). The discounted ICER comparing CXL to conventional management was Can$9090/QALY gained. Sensitivity analyses revealed that in general, parameter variations did not influence the cost-effectiveness of CXL. CXL is

  15. Penetrating keratoplasty for keratoconus: role of videokeratoscopy and trephine sizing.

    PubMed

    Serdarevic, O N; Renard, G J; Pouliquen, Y

    1996-11-01

    To evaluate whether determining graft-host trephine disparity on the basis of videokeratoscopic data of keratoconus patients having penetrating keratoplasty (PKP) reduces ametropia and to correlate preoperative videokeratoscopic values, posterior axial length (PAL), and trephine disparity with postoperative refractive outcomes. Hôtel-Dieu, University of Paris, France. This randomized clinical trial comprised 18 keratoconus patients who had PKP. After computerized videokeratoscopic analysis, patients were randomly assigned to a test or control group with matching for midperipheral corneal keratoscopic criteria. One surgeon performed all grafts using the same technique (except for donor button punching with an 8.00 or 8.25 mm blade, depending on preoperative keratoscopy) with suction trephination (8.00) and a running 10-0 nylon suture. The PAL (total axial length minus the distance from the anterior corneal surface to the anterior lens surface) was measured by applanation ultrasonography. Refraction and videokeratoscopic analysis were done 18 months postoperatively (6 months after suture removal). The mean deviation from emmetropia corrected for PAL in test group patients who had trephine sizing based on the hypothesis that preoperative videokeratoscopy is a useful determining factor was 1.12 diopters (D) +/- 0.74 (SD), which was significantly smaller (P = .005) than that in the control group (2.19 +/- 0.85 D). The test group had uncorrected visual acuities of 20/50 or better. Postoperative spherical equivalent was affected by PAL (P = .0001), preoperative keratoscopy (P = .0001), and trephine disparity (P = .01). Central corneal power after grafting was influenced by keratoscopy (P = .0001) and trephine disparity (P = .002). Uncorrected visual acuity was affected by PAL (P = .001) and keratoscopic data (P = .01). Parameters for reducing ametropia after grafting of keratoconus patients can be developed for each surgeon based on trephine disparity dependent on

  16. Mechanisms of rubbing-related corneal trauma in keratoconus.

    PubMed

    McMonnies, Charles W

    2009-07-01

    Corneal scarring in keratoconus, which is observed prior to contact lens wear and in association with a chronic habit of abnormal rubbing, suggests a keratocyte change to a repair phenotype in response to rubbing trauma. This review examines known and putative mechanisms for rubbing-related corneal trauma and cone formation. Responses to eye rubbing (and possible causal links) may include increased corneal temperature, epithelial thinning, increased concentrations of inflammatory mediators in the precorneal tears, abnormal enzyme activity, large intraocular pressure spikes, high hydrostatic tissue pressure, thixotropically reduced ground substance viscosity, temporary displacement of ground substance from the corneal apex, buckling and flexure of fibrils associated with waves of corneal indentation, biomechanically coupled curvature transfer to the cone apex, slippage between collagen fibrils at the cone apex, and changes to keratocytes due to mechanical trauma and/or high hydrostatic pressure, in addition to scar formation. Cone formation appears to depend on a loss of shear strength and may be a consequence of a reduction in ground substance viscosity and glue function, which could allow the cornea to bend and yield to intraocular pressure. For some forms of keratoconus, a reduction in shear strength and cone-forming deformation may be responses to rubbing trauma. Some of the mechanisms for corneal rubbing trauma may be relevant to post-laser-assisted in situ keratomileusis ectasia or complications following other types of corneal surgery. There appear to be indications for the control of chronic habits of abnormal rubbing.

  17. Rotating Scheimpflug Imaging Indices in Different Grades of Keratoconus

    PubMed Central

    2016-01-01

    Purpose. To evaluate accuracy of various Keratoconus (KC) screening indices, in relation to Topographic Keratoconus (TKC) grading. Setting. Al Watany Eye Hospital, Cairo, Egypt. Methods. Data of 103 normal (group 1) and 73 KC eyes (group 2), imaged by Pentacam (branded as Allegro Oculyzer), were analysed. Group 2 was divided into 2a: 14 eyes (TKC = 1, early KC), 2b: 25 eyes (TKC = 1 to 2 or 2, moderate KC), and 2c: 34 eyes (TKC = 2 to 3 up to 4, severe KC). Participants were followed up for six years to confirm diagnosis. Area under the receiver operating characteristic curve (AUROC) was calculated for evaluated curvature, elevation, and pachymetry indices with various reference shapes at different diameters. Results. When comparing normal to KC eyes, ten indices had significantly higher AUROC. Only five of them had significantly higher AUROC in early KC compared to normal corneas: Pachymetry Progression Index- (PPI-) Maximum (Max), Ambrósio's Relational Thickness- (ART-) Max, PPI-Max minus PPI-Minimum (Min), central corneal thickness (CCT), and diagonal decentration of thinnest point from the apex (AUROC = 0.690, 0.690, 0.687, 0.683, and 0.674, resp.). Conclusion. Generally, ten pachymetry and elevation-based indices had significantly higher AUROC. Five indices had statistically significant high AUROC when comparing early KC to normal corneas. PMID:27579178

  18. Which soft lens power is better for piggyback in keratoconus? Part II.

    PubMed

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; González-Meijóme, Jose-Manuel; Flores-Rodriguez, Patricia; Villa-Collar, Cesar

    2015-02-01

    To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus. Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of -6.00, -3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed. In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (p<0.05 in all cases), did not change with the +3.00 soft lens power (p=1.0); and steepened with the +6.00 soft lens power (p=0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p>0.05). RGP's BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all p<0.001), but no significant differences were found among negative- or positive-powers separately (both p>0.05). Estimated RGP's final power increased significantly with positive in comparison with negative lens powers (all p<0.001), but no significant differences were found among negative or positive lens powers separately (both p>0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p>0.05). The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Which soft contact lens power is better for piggyback fitting in keratoconus?

    PubMed

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose Manuel

    2013-02-01

    To evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus. Nineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of -3.00, -1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated. Negative- and plano-powered soft lenses flattened (p<0.05 in all cases), whereas positive-powered lenses did not induce any significant changes (p>0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (p<0.05 in both cases) and increased with +3.00 D lenses (p=0.03) in comparison to the naked eye. No statistically significant differences were found in MFE with any soft lens power in comparison to the naked eye (p>0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p<0.05 in all cases). No statistically differences were found in HOA RMS and spherical-like aberration (both p>0.05). Statistically differences were found in coma-like and secondary astigmatism (both p<0.05). Negative-powered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Influence of Posterior Corneal Astigmatism on Total Corneal Astigmatism in Eyes With Keratoconus.

    PubMed

    Savini, Giacomo; Næser, Kristian; Schiano-Lomoriello, Domenico; Mularoni, Alessandro

    2016-11-01

    To measure posterior corneal astigmatism (PCA) and investigate its influence on total corneal astigmatism (TCA) in eyes with keratoconus. Keratometric astigmatism (KA), PCA, and TCA were investigated by means of a dual Scheimpflug analyzer in patients with keratoconus. Vector analysis was carried out with the Næser polar value method. We enrolled 119 eyes. PCA magnitude averaged 0.77 ± 0.43 diopters (D) and exceeded 0.50, 1.00, and 2.00 D in 73.9%, 21.8%, and 16.8% of eyes, respectively. PCA averaged 0.95 ± 0.48, 0.55 ± 0.28, and 0.70 ± 0.35 D in eyes with with-the-rule (WTR), against-the-rule (ATR), and oblique astigmatism. The steepest posterior meridian was oriented vertically (between 61 and 119 degrees) in 55.5% of eyes, thus generating ATR astigmatism. The difference between the location of the steepest meridian of KA and that of TCA was >10 degrees in 8.4% of eyes. On average, KA overestimated TCA in eyes with WTR astigmatism by 0.16 D and underestimated TCA in eyes with ATR astigmatism by 0.22 D. The PCA power oriented along the steeper anterior corneal meridian averaged -0.83 ± 0.40, -0.40 ± 0.37, and -0.53 ± 0.43 D for WTR, ATR, and obliquely astigmatic eyes, respectively. Linear regression disclosed a statistically significant correlation (P < 0.0001, r = 0.16) between the meridional powers of TCA and PCA. In eyes with keratoconus, PCA displays large, variable values and is correlated to TCA. The influence of PCA on TCA cannot be disregarded when planning astigmatism correction by toric intraocular lenses.

  1. An Analysis of Factors Influencing Quality of Vision After Big-Bubble Deep Anterior Lamellar Keratoplasty in Keratoconus.

    PubMed

    Feizi, Sepehr; Javadi, Mohammad Ali; Mohammad-Rabei, Hossein

    2016-02-01

    To identify causes of reduced visual acuity and contrast sensitivity after big-bubble deep anterior lamellar keratoplasty (DALK) in keratoconus. Prospective interventional case series. This study included 36 eyes in 36 patients with keratoconus who underwent DALK using the big-bubble technique. A bare Descemet membrane was achieved in all cases. Univariate analyses and multiple linear regression were used to investigate recipient-, donor-, and postoperative-related variables capable of influencing the postoperative quality of vision, including best spectacle-corrected visual acuity (BSCVA) and contrast sensitivity. The mean patient age was 27.7 ± 6.9 years, and the patients were followed for 24.6 ± 15.1 months postoperatively. The mean postoperative BSCVA was 0.17 ± 0.09 logMAR. Postoperative BSCVA ≥20/25 was achieved in 14 eyes (38.9%), whereas a BSCVA of 20/30, 20/40, or 20/50 was observed in 15 eyes (41.7%), 6 eyes (16.6%), and 1 eye (2.8%), respectively. Preoperative vitreous length was significantly associated with postoperative BSCVA (β = 0.02, P = .03). Donor-recipient interface reflectivity significantly influenced scotopic (β = -0.002, P = .04) and photopic (β = -0.003, P = .02) contrast sensitivity. The root mean square of tetrafoil was significantly negatively associated with scotopic (β = -0.25, P = .01) and photopic (β = -0.23, P = .04) contrast sensitivity. Recipient age, keratoconus severity, donor-related variables, recipient trephination size, and graft and recipient bed thickness were not significantly associated with postoperative visual acuity or contrast sensitivity. Large vitreous length, higher-order aberrations, and surgical interface haze may contribute to poor visual outcomes after big-bubble DALK in keratoconus. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Simultaneous topography-guided PRK followed by corneal collagen cross-linking after lamellar keratoplasty for keratoconus.

    PubMed

    Spadea, Leopoldo; Paroli, Marino

    2012-01-01

    The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (-6.11 D ± 2.48, range -2.50 to -9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. After a mean 15 ± 6.5 (range 6-24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1-10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was -0.79 ± 2.09 (range +1 to -3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8-8.9) D. All the corneas remained clear (haze < 1). The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus.

  3. Signs and Symptoms of Dry Eye in Keratoconus Patients Before and After Intrastromal Corneal Rings Surgery.

    PubMed

    Carracedo, Gonzalo; Recchioni, Alberto; Alejandre-Alba, Nicolás; Martin-Gil, Alba; Batres, Laura; Morote, Ignacio Jimenez-Alfaro; Pintor, Jesús

    2017-04-01

    Based on the relationship between keratoconus and dry eye, the aim of this study was to evaluate changes in signs and symptoms of dry eye in keratoconus patients before and after intrastromal corneal ring surgery. Fifteen keratoconus patients were enrolled in Fundación Jiménez-Díaz of Madrid and University Clinic of Optometry of the Universidad Complutense de Madrid (Madrid, Spain). Tear break up time (TBUT), Schirmer test without anesthesia, corneal staining, diadenosine tetraphosphate (Ap 4 A) concentration, and ocular surface disease index (OSDI) were evaluated. Impression cytology combined with laser confocal microscopy was performed to evaluate goblet cell density, mucin cloud height (MCH), and cell layer thickness (CLT). All measurements were performed before (pre) surgery, 1 month (post) and 6 months after surgery (post6m). We found no statistical differences in time in Schirmer test, TBUT, and corneal staining. OSDI scores were 44.96  ±  8.65, 26.30 ± 6.79, and 19.31 ± 4.28 for (pre), (post), and (post6m) surgery, respectively (p < 0.001). Impression cytology showed a decrease in cell density at (post6m) compared with presurgery (47.36 ± 35.15 cells/mm 2 and 84.88 ± 32.08 cells/mm 2 , respectively, p = 0.04). At post6m, the MCH increased compared with presurgery values (13.97 ± 4.26 µm and 6.77 ± 2.51 µm, respectively, p < 0.001). There was a statistically significant increase in CLT in time. Ap 4 A tear concentrations were lower post6m than presurgery (1.02  ±  0.65 and 2.56   ± 1.10  µM, respectively, p < 0.001). Intrastromal corneal ring surgery induces changes improving dry eye symptoms but no changes were found in signs of dry eye after surgery in keratoconus patients except for the MCH that increases drastically. More studies are needed to clarify the reason of its improvement.

  4. Effects of vernal and allergic conjunctivitis on severity of keratoconus.

    PubMed

    Cingu, Abdullah Kursat; Cinar, Yasin; Turkcu, Fatih Mehmet; Sahin, Alparslan; Ari, Seyhmus; Yuksel, Harun; Sahin, Muhammed; Caca, Ihsan

    2013-01-01

    To demonstrate the effects of two different types of allergic conjunctivitis on severity of keratoconus (KC). We retrospectively reviewed the medical records of 171 KC patients referred between June 2010 and June 2011. The KC patients were divided into 3 groups as KC (group A), KC with vernal keratoconjunctivitis (VKC) (group B) and KC with allergic conjunctivitis (AC) (group C). Main outcome measures were demographic and ocular clinical features including age at presentation, gender, spherical equivalent (SE), best spectacle corrected visual acuity (BCVA), mean keratometric measurement (Km), central corneal thickness (CCT), and intraocular pressure (IOP). Groups were compared in term of study variables. The median age at presentation was significantly lower in group B (P<0.001). According to the median SE (P=0.003), BCVA (P=0.022), Km (P<0.001), CCT (P=0.015) and Amsler-Krumeich classification (P<0.001), KC was more severe in group B. There was no significant difference in terms of IOP and corrected IOP among the groups (P=0.44), however there were 4 patients who had increased corrected IOP developed after topical corticosteroid use in group B. The differences among the groups persisted even after controlling for age and gender. Our findings demonstrated a more severe KC in VKC patients despite their younger age which suggests evaluation of VKC patients as a separate group in keratoconus disease.

  5. In vitro model suggests oxidative stress involved in keratoconus disease

    PubMed Central

    Karamichos, D.; Hutcheon, A. E. K.; Rich, C. B.; Trinkaus-Randall, V.; Asara, J. M.; Zieske, J. D.

    2014-01-01

    Keratoconus (KC) affects 1:2000 people and is a disorder where cornea thins and assumes a conical shape. Advanced KC requires surgery to maintain vision. The role of oxidative stress in KC remains unclear. We aimed to identify oxidative stress levels between human corneal keratocytes (HCKs), fibroblasts (HCFs) and keratoconus cells (HKCs). Cells were cultured in 2D and 3D systems. Vitamin C (VitC) and TGF-β3 (T3) were used for 4 weeks to stimulate self-assembled extracellular matrix (ECM). No T3 used as controls. Samples were analyzed using qRT-PCR and metabolomics. qRT-PCR data showed low levels of collagen I and V, as well as keratocan for HKCs, indicating differentiation to a myofibroblast phenotype. Collagen type III, a marker for fibrosis, was up regulated in HKCs. We robustly detected more than 150 metabolites of the targeted 250 by LC-MS/MS per condition and among those metabolites several were related to oxidative stress. Lactate levels, lactate/malate and lactate/pyruvate ratios were elevated in HKCs, while arginine and glutathione/oxidized glutathione ratio were reduced. Similar patterns found in both 2D and 3D. Our data shows that fibroblasts exhibit enhanced oxidative stress compared to keratocytes. Furthermore the HKC cells exhibit the greatest level suggesting they may have a myofibroblast phenotype. PMID:24714342

  6. Short-term Effect of Scleral Lens on the Dry Eye Biomarkers in Keratoconus.

    PubMed

    Carracedo, Gonzalo; Blanco, Maria Serramito; Martin-Gil, Alba; Zicheng, Wang; Alvarez, Jesús Carballo; Pintor, Jesús

    2016-02-01

    To evaluate the most important signs of dry eye, such as osmolarity, inflammation, and diadenosine tetraphosphate (Ap(4)A) concentration before and after wearing scleral lenses for 8 h in keratoconus patients. A pilot, experimental, short-term study involved 26 keratoconus patients (average age, 36.95 ± 8.95 years). They voluntarily enrolled in the study at the Optometry Clinic of the Faculty of Optics and Optometry in the University Complutense of Madrid. They were divided into two groups: patients with intrastromal corneal ring, the ICRS group, and patients without ICRS, the keratoconus (KC) group. Ocular Surface Disease Index questionnaire, the Schirmer test without anesthesia, tear break-up time, matrix metalloproteinase 9 (MMP-9) concentration, osmolarity, and Ap4A concentration were evaluated before and after wearing a scleral lens for 8 h. The patients wore the scleral lenses from 6 to 9 h, with a mean of 7.59 ± 0.73 h. The mean scleral lens sag for all patients was 4310 ± 166.31 μm, ranging from 4200 μm to 4800 μm. No significant changes in the Schirmer test and tear break-up time were found for either group. Ocular Surface Disease Index scores were statistically lower after wearing scleral lenses for both groups (p < 0.05). A significantly lower osmolarity and a significant rise of MMP-9 concentration after wearing scleral lenses were found in both groups (p < 0.05). Diadenosine tetraphosphate concentration was lower after wearing the scleral lens in the KC group (p < 0.05) but no significant difference was found for the ICRS group (p > 0.05). Short-term scleral lens wearing improves the symptomatology and some signs of dry eye, such as osmolarity and Ap4A concentration. The increase of MMP-9 concentration could be caused by tear film stagnation and use of preserved saline.

  7. Simulation of keratoconus observation in photorefraction

    NASA Astrophysics Data System (ADS)

    Chen, Ying-Ling; Tan, B.; Baker, K.; Lewis, J. W. L.; Swartz, T.; Jiang, Y.; Wang, M.

    2006-11-01

    In the recent years, keratoconus (KC) has increasingly gained attention due to its treatment options and to the popularity of keratorefractive surgery. This paper investigates the potential of identification of KC using photorefraction (PR), an optical technique that is similar to objective retinoscopy and is commonly used for large-scale ocular screening. Using personalized eye models of both KC and pre-LASIK patients, computer simulations were performed to achieve visualization of this ophthalmic measurement. The simulations are validated by comparing results to two sets of experimental measurements. These PR images show distinguishable differences between KC eyes and eyes that are either normal or ametropic. The simulation technique with personalized modeling can be extended to other ophthalmic instrument developments. It makes possible investigation with the least number of real human subjects. The application is also of great interest in medical training.

  8. Comparison of femtosecond laser-assisted descemetic and predescemetic lamellar keratoplasty for keratoconus.

    PubMed

    Lu, Yan; Grisolia, Ana Beatriz Diniz; Ge, Yi-Rui; Xue, Chun-Yan; Cao, Qian; Yang, Li-Ping; Huang, Zhen-Ping

    2017-01-01

    The purpose of this study is to compare the outcomes following femtosecond laser-assisted deep anterior lamellar keratoplasty (DALK) with 75% of stromal dissection (predescemetic group) and femtosecond laser-assisted DALK using big-bubble technique with total stromal resection (descemetic group) for the treatment of keratoconus. Twenty eyes of 17 patients with keratoconus were studied. There were 10 eyes of 9 patients in predescemetic group and 10 eyes of 8 patients in descemetic group. The postoperative best-corrected visual acuity (BCVA), manifest refraction, keratometry, endothelial cell density (ECD), and central corneal thickness (CCT) were analyzed. All surgeries were performed uneventfully. At 1 year after surgery, the BCVA, corneal astigmatism, keratometry, CCT, and ECD between two groups were not statistically significant (all P > 0.05). However, the mean manifest refraction was -9.43 ± 7.44 diopter (D) and -1.03 ± 1.13D in predescemetic and descemetic groups, respectively, which was statistically significant between two groups (P < 0.05). The results of BCVA and corneal astigmatism, keratometry, ECD, and CCT were comparable between two groups. However, the mean postoperative manifest refraction was lower in descemetic group.

  9. A case of unilateral circumscribed posterior keratoconus evaluated by three different imaging tools: optical coherence tomography, videokeratography, and Scheimpflug corneal tomography.

    PubMed

    Spadea, Leopoldo; Maraone, Giorgia; Cagini, Carlo

    2017-02-01

    Posterior keratoconus is a rare corneal anomaly which is part of the ectatic corneal disorders. We report a clinical presentation of a unilateral posterior keratoconus in a 42-year-old man. At the time of presentation, corrected distance visual acuity (CDVA) was 20/20 with a correction of +2.50 +2.50 × 90° in the right eye and 20/40 with +1 +3.00 × 105° in the left eye. Slit lamp microscopy showed in the left eye an evidence of corneal thinning with a mild anterior protrusion and a remarkable posterior excavation. The intraocular pressure was 19 mmHg in right eye and 16 mmHg in left eye. Ultrasound pachymetry showed a minimum corneal thickness of 556 μ in right eye and 289 μ in left eye. The anterior segment optical coherence tomography (AS-OCT) revealed central corneal thinning and showed a reduced epithelial thickness. Videokeratography showed an increase of the corneal curvature in a defined area with central steepening in the area of the posterior corneal depression with gradual paracentral flattening. The description of this case underlines the importance of this instruments such us AS-OCT and corneal topography in diagnosis of posterior keratoconus. It can also be observed that in the contralateral eye there are no signs of ectasia as in the rare condition of unilateral keratoconus.

  10. Simultaneous topography-guided PRK followed by corneal collagen cross-linking after lamellar keratoplasty for keratoconus

    PubMed Central

    Spadea, Leopoldo; Paroli, Marino

    2012-01-01

    Background The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. Methods The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (−6.11 D ± 2.48, range −2.50 to −9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. Results After a mean 15 ± 6.5 (range 6–24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1–10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was −0.79 ± 2.09 (range +1 to −3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8–8.9) D. All the corneas remained clear (haze < 1). Conclusion The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus. PMID:23152658

  11. Effects of the rigid gas permeable contact lense use on tear and ocular surface among keratoconus patients.

    PubMed

    Yuksel Elgin, Cansu; Iskeleli, Guzin; Aydin, Ovgu

    2018-06-01

    To investigate changes in tear and ocular surface of patients with keratoconus using rigid gas permeable contact lenses (RGPCL) and compare them against keratoconus patients who were not using lenses as well as a control group of healthy subjects. 24 keratoconus patients using RGPCL (Group 1) 22 patients who were not using lenses (Group 3) and 21 healthy subjects (Group 3) were included in the study. Subjective complaints about the subjects' eyes have been investigated using the ocular-surface disease index (OSDI). After the control of best-corrected visual acuity, anterior chamber and fundus examinations were performed. Schirmer (p-value=0.01) and tear break up mean comparison tests (p-value=0.002) revealed significant differences across different groups but tear osmolarity analysis did not (p-value >0.05). Oxford and OSDI scores were compatible with Schirmer and tear break up test comparisons. (for both p-value=0.001) Moreover, no statistical differences were seen in impression cytology measures between groups. (p-value >0.05) CONCLUSIONS: The erosion in the tear film stability is in line with the erosion in the ocular surface epithelium. Taking into account the statistical indifference between the impression cytology measures across groups, the break up time differences may be attributed to the collagen destruction in tear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Effects of vernal and allergic conjunctivitis on severity of keratoconus

    PubMed Central

    Cingu, Abdullah Kursat; Cinar, Yasin; Turkcu, Fatih Mehmet; Sahin, Alparslan; Ari, Seyhmus; Yuksel, Harun; Sahin, Muhammed; Caca, Ihsan

    2013-01-01

    AIM To demonstrate the effects of two different types of allergic conjunctivitis on severity of keratoconus (KC). METHODS We retrospectively reviewed the medical records of 171 KC patients referred between June 2010 and June 2011. The KC patients were divided into 3 groups as KC (group A), KC with vernal keratoconjunctivitis (VKC) (group B) and KC with allergic conjunctivitis (AC) (group C). Main outcome measures were demographic and ocular clinical features including age at presentation, gender, spherical equivalent (SE), best spectacle corrected visual acuity (BCVA), mean keratometric measurement (Km), central corneal thickness (CCT), and intraocular pressure (IOP). Groups were compared in term of study variables. RESULTS The median age at presentation was significantly lower in group B (P<0.001). According to the median SE (P=0.003), BCVA (P=0.022), Km (P<0.001), CCT (P=0.015) and Amsler–Krumeich classification (P<0.001), KC was more severe in group B. There was no significant difference in terms of IOP and corrected IOP among the groups (P=0.44), however there were 4 patients who had increased corrected IOP developed after topical corticosteroid use in group B. The differences among the groups persisted even after controlling for age and gender. CONCLUSION Our findings demonstrated a more severe KC in VKC patients despite their younger age which suggests evaluation of VKC patients as a separate group in keratoconus disease. PMID:23826535

  13. Collagen crosslinking for ectasia following PRK performed in excimer laser-assisted keratoplasty for keratoconus.

    PubMed

    Spadea, Leopoldo

    2012-01-01

    To report the results of corneal collagen crosslinking (CXL) in a patient with corneal ectasia developed after excimer laser-assisted lamellar keratoplasty for keratoconus and a secondary photorefractive keratectomy (PRK) for residual refractive error. A 33-year-old woman, who had originally been treated for keratoconus in the right eye by excimer laser-assisted lamellar keratoplasty, subsequently had her residual ametropia treated by topographically guided, transepithelial excimer laser PRK. Five years after PRK, the patient developed corneal ectasia showing concomitant visual changes of best spectacle-corrected visual acuity (BSCVA) reduced to 20/33 with a refraction of -6.00 +6.00 × 30. The minimum corneal thickness at the ectasia apex was 406 µm. A treatment of riboflavin-UVA-induced corneal CXL was performed on the right eye. Two years after the CXL treatment, the right eye improved to 20/20 BSCVA with a refraction of plano +1.00 × 50 while exhibiting a clear lamellar graft. Corneal CXL provided safe and effective management of ectasia developed after excimer laser-assisted lamellar keratoplasty and PRK.

  14. Outcomes of Same-Size Host and Donor Trephine in Deep Anterior Lamellar Keratoplasty for Keratoconus.

    PubMed

    Huang, Ting; Ouyang, Chen; Hou, Chao; Wu, Qianni; Hu, Yunwei

    2016-06-01

    To evaluate the efficacy of the same-size host and donor trephine on reducing myopic refractive errors for patients with keratoconus when deep anterior lamellar keratoplasty (DALK) was used. Randomized controlled clinical trial. One hundred eighteen eyes of 118 patients with keratoconus were enrolled. Using stratified blocked randomization, eligible eyes were allocated into the same-size trephine group or oversize trephine group. Postoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), spherical equivalent (SE), topography data, and eye axial length were compared at each year for 5 years. The same-size trephine group had comparable UCVA to the oversize trephine group through 5 years after surgery. But the former had better BSCVA than the latter after 3 years of follow-up. At 5 years, mean BSCVA was 0.17 ± 0.10 logMAR in the same-size trephine group vs 0.25 ± 0.13 logMAR in the oversize trephine group (P = .03). The same-size trephine group had lower topographic power than the oversize trephine group after 3 years of follow-up. At 5 years, mean topographic power was 45.30 ± 2.28 diopters (D) in the same-size trephine group vs 46.75 ± 2.60 D in the oversize trephine group (P = .006). Eye axial lengths at 5 years were longer than those preoperatively as well as at 1 year follow-up after surgery in both groups. The same-size host and donor trephine could reduce late-stage myopic refractive errors for the patients with keratoconus after DALK. The mechanism may be late-stage axial length increase with time. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Effects of central corneal thickness on measurement of intra-ocular pressure in keratoconus and post-keratoplasty.

    PubMed

    Patel, S; McLaughlin, J M

    1999-05-01

    To measure and compare central corneal thickness (CT) and intraocular pressure (IOP) in keratoconus and post-keratoplasty subjects and examine the CT-IOP relationship. 22 keratoconus (category I: six female sixteen male, average age 27.0 range 12-47) and 19 post-keratoplasty (category II: ten female nine male average age 34.6 range 16-54) patients without other anterior segment conditions were recruited. Only one, non-contact lens wearing, eye of the patient was included for analysis. Cornea was anaesthetised with non-preserved 0.4% Benoxinate Hydrochloride. Using a randomised approach, CT was measured using a standard ultrasonic pachymeter. IOP was then measured using a standard Goldmann tonometer. At all times the tonometrist remained unaware of the corneal thickness values. The mean (+/- s.d.) values for CT and IOP respectively in the two categories were: (I), 445 (45) mu and 9.8 (2.3) mmHg, (II), 564(44) microns and 15.8 (3.9) mmHg. Differences between I and II for both CT and IOP were significant (t-test, p = 0.01). Within each category, a significant correlation between CT and IOP was not found. Pooling all pairs of data (n = 41) a significant relationship between CT and IOP was detected (r = 0.635, p = 0.0001). The results confirm the hypothesis that an eye with a thicker cornea tends to present with a higher measured IOP. In the management of keratoconus and other corneal surgical procedures, changes in CT will contribute to any apparent changes in measured IOP.

  16. Efficacy of Corneal Collagen Cross-Linking for Treatment of Keratoconus: A Meta-Analysis of Randomized Controlled Trials

    PubMed Central

    Lin, Xiaoti

    2015-01-01

    Objective To evaluate the efficacy of corneal collagen cross-linking (CXL) for the treatment of keratoconus. Methods We performed a literature search for randomized controlled trials that assessed the effect of CXL in slowing progression of keratoconus. The primary outcome measures included changes of topographic parameters, visual acuity, and refraction. Efficacy estimates were evaluated by weighted mean difference (WMD) and 95% confidence interval (CI) for absolute changes of the interested outcomes. Results Significant decrease in mean keratometry value, maximum keratometry value and minimum keratometry value were demonstrated in the CXL group compared with the control group (WMD = -1.65; 95% CI: -2.51 to -0.80; P < 0.00001; WMD = -2.05; 95% CI: -3.10 to -1.00; P < 0.00001; WMD = -1.94; 95% CI: -2.63 to -1.26; P < 0.00001; respectively). Best spectacle-corrected visual acuity improved significantly in CXL group (WMD = -0.10; 95% CI: -0.15 to -0.05; P < 0.00001), whereas uncorrected visual acuity did not differ statistically. Manifest cylinder error decreased significantly in patients undergoing CXL procedure compared with control patients in sensitivity analysis (WMD = -0.388; 95% CI: -0.757 to -0. 019; P = 0.04). The changes in central corneal thickness and intraocular pressure were not statistically significant. Conclusion CXL may be an effective option in stabilizing keratoconus. Further long-term follow-up studies will be necessary to assess the persistence of CXL. PMID:25985208

  17. Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism.

    PubMed

    Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina

    2017-10-01

    To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 20/32 with +8.00/-4.50×30° for the right eye (RE) and 20/25 with +7.75/-2.25×120° for the left eye (LE). After CScL fitting, visual acuity was improved to 20/20 and 20/16 for the RE and LE, respectively. The patient wore these contact lenses an average of 13h a day. The total high order aberrations decreased by approximately 79% in the RE (2.37-0.50μm) and 47% in the LE (1.04-0.55μm) after CScL fitting. Visual quality and wearing time were maintained after 1year wearing CScL. In addition, no adverse ocular effects were found during this period. The present case report describes how the patient had CScL fitted successfully for management of keratoconus with high hyperopia and astigmatism. They provided optimal visual quality, along with prolonged use times and no adverse effects to the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. New approach for correction of error associated with keratometric estimation of corneal power in keratoconus.

    PubMed

    Camps, Vicente J; Piñero, David P; Caravaca-Arens, Esteban; de Fez, Dolores; Pérez-Cambrodí, Rafael J; Artola, Alberto

    2014-09-01

    The aim of this study was to obtain the exact value of the keratometric index (nkexact) and to clinically validate a variable keratometric index (nkadj) that minimizes this error. The nkexact value was determined by obtaining differences (ΔPc) between keratometric corneal power (Pk) and Gaussian corneal power ((Equation is included in full-text article.)) equal to 0. The nkexact was defined as the value associated with an equivalent difference in the magnitude of ΔPc for extreme values of posterior corneal radius (r2c) for each anterior corneal radius value (r1c). This nkadj was considered for the calculation of the adjusted corneal power (Pkadj). Values of r1c ∈ (4.2, 8.5) mm and r2c ∈ (3.1, 8.2) mm were considered. Differences of True Net Power with (Equation is included in full-text article.), Pkadj, and Pk(1.3375) were calculated in a clinical sample of 44 eyes with keratoconus. nkexact ranged from 1.3153 to 1.3396 and nkadj from 1.3190 to 1.3339 depending on the eye model analyzed. All the nkadj values adjusted perfectly to 8 linear algorithms. Differences between Pkadj and (Equation is included in full-text article.)did not exceed ±0.7 D (Diopter). Clinically, nk = 1.3375 was not valid in any case. Pkadj and True Net Power and Pk(1.3375) and Pkadj were statistically different (P < 0.01), whereas no differences were found between (Equation is included in full-text article.)and Pkadj (P > 0.01). The use of a single value of nk for the calculation of the total corneal power in keratoconus has been shown to be imprecise, leading to inaccuracies in the detection and classification of this corneal condition. Furthermore, our study shows the relevance of corneal thickness in corneal power calculations in keratoconus.

  19. Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus.

    PubMed

    Szalai, Eszter; Berta, András; Hassan, Ziad; Módis, László

    2012-03-01

    To evaluate the repeatability and reliability of a recently introduced swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) system and a high-resolution Scheimpflug camera and to assess the agreement between the 2 instruments when measuring healthy eyes and eyes with keratoconus. Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary. Evaluation of diagnostic test or technology. Three consecutive series of anterior segment images were taken with AS-OCT (Casia SS-1000) followed by rotating Scheimpflug imaging (Pentacam high resolution). Axial keratometry in the steep and flat meridians and astigmatism values were recorded. Pachymetry in the apex, center, and the thinnest position and anterior chamber depth (ACD) measurements were also taken. This study enrolled 57 healthy volunteers (57 eyes) and 56 patients (84 eyes) with keratoconus. Significant difference was found in all measured anterior segment parameters between normal eyes and keratoconic eyes (P<.05). In keratoconic eyes, the difference between repeated measurements was less with AS-OCT than with Scheimpflug imaging in every keratometry and astigmatism value, in apical thickness, and in ACD. For keratometry, the thinnest and central pachymetry measurement repeatability was better in healthy eyes than in keratoconic eyes with both instruments. In general, the mean difference between AS-OCT and Scheimpflug imaging was higher in cases of keratoconus. Significant differences in keratometry, pachymetry, and ACD results were found between AS-OCT and Scheimpflug imaging. However, the repeatability of the measurements was comparable. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Wavefront-Guided Scleral Lens Prosthetic Device for Keratoconus

    PubMed Central

    Sabesan, Ramkumar; Johns, Lynette; Tomashevskaya, Olga; Jacobs, Deborah S.; Rosenthal, Perry; Yoon, Geunyoung

    2016-01-01

    Purpose To investigate the feasibility of correcting ocular higher order aberrations (HOA) in keratoconus (KC) using wavefront-guided optics in a scleral lens prosthetic device (SLPD). Methods Six advanced keratoconus patients (11 eyes) were fitted with a SLPD with conventional spherical optics. A custom-made Shack-Hartmann wavefront sensor was used to measure aberrations through a dilated pupil wearing the SLPD. The position of SLPD, i.e. horizontal and vertical decentration relative to the pupil and rotation were measured and incorporated into the design of the wavefront-guided optics for the customized SLPD. A submicron-precision lathe created the designed irregular profile on the front surface of the device. The residual aberrations of the same eyes wearing the SLPD with wavefront-guided optics were subsequently measured. Visual performance with natural mesopic pupil was compared between SLPDs having conventional spherical and wavefront-guided optics by measuring best-corrected high-contrast visual acuity and contrast sensitivity. Results Root-mean-square of HOA(RMS) in the 11 eyes wearing conventional SLPD with spherical optics was 1.17±0.57μm for a 6 mm pupil. HOA were effectively corrected by the customized SLPD with wavefront-guided optics and RMS was reduced 3.1 times on average to 0.37±0.19μm for the same pupil. This correction resulted in significant improvement of 1.9 lines in mean visual acuity (p<0.05). Contrast sensitivity was also significantly improved by a factor of 2.4, 1.8 and 1.4 on average for 4, 8 and 12 cycles/degree, respectively (p<0.05 for all frequencies). Although the residual aberration was comparable to that of normal eyes, the average visual acuity in logMAR with the customized SLPD was 0.21, substantially worse than normal acuity. Conclusions The customized SLPD with wavefront-guided optics corrected the HOA of advanced KC patients to normal levels and improved their vision significantly. PMID:23478630

  1. Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes.

    PubMed

    Wu, Wenjing; Wang, Yan; Xu, Lulu

    2014-01-01

    The aim of this meta-analysis is to evaluate the central corneal thickness (CCT) measurement differences between Pentacam (Oculus Inc., Germany) and Ultrasound Pachymetry (USP) in normal (unoperated eyes , myopic and astigmatic eyes without corneal disease or topographic irregularity), after laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), and keratoconic or keratoconus suspected eyes. We assess whether Pentacam and USP have similar CCT differences in normal, thinner corneas after LASIK or PRK procedures, and kerotoconic or keratoconus suspected eyes. Data sources, including PubMed, Medline, EMBASE, and Cochrane Central Registry of Controlled Trials on the Cochrane Library, were searched to find the relevant studies. Primary outcome measures were CCT measurement between Pentacam and USP. Three groups of eyes were analyzed: normal; LASIK or PRK eyes; and keratoconus suspected or keratoconic eyes. Nineteen studies describing 1,908 eyes were enrolled in the normal group. Pentacam results were 1.47 μm ,95 % confidence interval (CI) -2.32 to 5.27, higher than USP without statistically significant difference (P = 0.45). Nine studies with total 539 eyes were included in the corneas after LASIK or PRK. The mean difference in the CCT measurement with Pentacam and ultrasound pachymetry was 1.03 μm, with the 95 % CI -3.36 to 5.42, there was no statistically difference (P = 0.64). Four studies with a total of 185 eyes were included in the keratoconic eyes or keratoconus-suspect group, however,the mean difference was -6.33 μm (95 % CI -9.17 to-3.49), which was statistically different between Pentacam and ultrasound pachymetry in the CCT measurement (P < 0.0001). Pentacam offers similar CCT results to ultrasound pachymetry in normal eyes, thinner corneas after LASIK or PRK procedures. However, in keratoconic or keratoconus-suspect eyes, Pentacam slightly underestimates the central corneal thickness than does ultrasound pachymetry

  2. Refractive improvements and safety with topography-guided corneal crosslinking for keratoconus: 1-year results.

    PubMed

    Nordström, Maria; Schiller, Maria; Fredriksson, Anneli; Behndig, Anders

    2017-07-01

    To assess the refractive improvements and the corneal endothelial safety of an individualised topography-guided regimen for corneal crosslinking in progressive keratoconus. An open-label prospective randomised clinical trial was performed at the Department of Clinical Sciences, Ophthalmology, Umeå University Hospital, Umeå, Sweden. Thirty-seven patients (50 eyes) with progressive keratoconus planned for corneal crosslinking were included. The patients were randomised to topography-guided crosslinking (photorefractive intrastromal crosslinking (PiXL); n=25) or uniform 9 mm crosslinking (corneal collagen crosslinking (CXL); n=25). Visual acuity, refraction, keratometry (K1, K2 and K max ) and corneal endothelial morphometry were assessed preoperatively and at 1, 3, 6 and 12 months postoperatively. The PiXL treatment involved an asymmetrical treatment zone centred on the area of maximum corneal steepness with treatment energies ranging from 7.2 to 15.0 J/cm 2 ; the CXL treatment was a uniform 9 mm 5.4 J/cm 2 pulsed crosslinking. The main outcome measures were changes in refractive errors and corneal endothelial cell density. The spherical refractive errors decreased (p<0.05) and the visual acuity improved (p<0.01) at 3, 6 and 12 months after PiXL, but not after CXL. The between-groups differences, however, were not significant. K2 and K max decreased at 3, 6 and 12 months after PiXL (p<0.01), but not after CXL (p<0.01 when comparing the two treatments). No corneal endothelial cell loss was seen after either treatment. Individualised topography-based crosslinking treatment centred on the ectatic cone has the potential to improve the corneal shape in keratoconus with decreased spherical refractive errors and improved visual acuity, without damage to the corneal endothelium. NCT02514200, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Simultaneous versus Sequential Accelerated Corneal Collagen Cross-Linking and Wave Front Guided PRK for Treatment of Keratoconus: Objective and Subjective Evaluation

    PubMed Central

    El Emam, Dalia Sabry; Farag, Rania Kamel; Abouelkheir, Hossam Youssef

    2016-01-01

    Aim. To compare objective and subjective outcome after simultaneous wave front guided (WFG) PRK and accelerated corneal cross-linking (CXL) in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods. 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results. All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P < 0.001). A significant improvement was observed in keratometric and Q values. The improvement in all parameters was stable till the end of follow-up. Likewise, no significant difference was determined in between the 2 groups in any of recorded parameters. Subjective data revealed similarly significant improvement in both groups. Conclusions. WFG PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure. PMID:28127465

  4. Simultaneous versus Sequential Accelerated Corneal Collagen Cross-Linking and Wave Front Guided PRK for Treatment of Keratoconus: Objective and Subjective Evaluation.

    PubMed

    Abou Samra, Waleed Ali; El Emam, Dalia Sabry; Farag, Rania Kamel; Abouelkheir, Hossam Youssef

    2016-01-01

    Aim . To compare objective and subjective outcome after simultaneous wave front guided (WFG) PRK and accelerated corneal cross-linking (CXL) in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods . 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results . All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P < 0.001). A significant improvement was observed in keratometric and Q values. The improvement in all parameters was stable till the end of follow-up. Likewise, no significant difference was determined in between the 2 groups in any of recorded parameters. Subjective data revealed similarly significant improvement in both groups. Conclusions . WFG PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure.

  5. Keratoconus and Normal-Tension Glaucoma: A Study of the Possible Association with Abnormal Biomechanical Properties as Measured by Corneal Hysteresis (An AOS Thesis)

    PubMed Central

    Cohen, Elisabeth J.

    2009-01-01

    Purpose: To test the hypothesis that keratoconus and pellucid patients who have glaucoma or are suspected of having glaucoma have lower corneal hysteresis (CH) and/or corneal resistance factor (CRF) measurements compared to controls. Methods: A prospective study at a tertiary eye center of keratoconus and pellucid patients with glaucoma or suspected of having glaucoma, and age-matched keratoconus and pellucid controls, was performed. After informed consent was obtained, corneal topography, ocular response analyzer measurements, pachymetry, intraocular pressure, A-scan measurements, Humphrey visual fields (VFs), and disc photos were done. Analyses compared cases to controls on primary (CH and CRF) and secondary variables. Disc photos and VFs were rated in a masked fashion. Results: The mean CH (8.2, SD=1.6, vs 8.3, SD=1.5) and CRF (7.3, SD=2.0, vs 6.9, SD=2.1) were low and did not differ significantly between 20 study patients (29 eyes) and 40 control patients (61 eyes), respectively. CH had a negative, significant correlation with maximum corneal curvature by topography (P < .002) and positive, significant correlation with central corneal thickness (P < .003). The mean cup-disc ratio was larger among cases than controls (0.54, SD=0.20, vs 0.38, SD=0.20; P = .003). VFs were suggestive of glaucoma more often among the study eyes than controls (11 of 29, 37.9%, vs 8 of 60, 13.3%; P =.019). Conclusions: CH was low in study and control patients and was correlated with severity of keratoconus/pellucid, but not with glaucoma/suspected glaucoma or control status. Evidence of glaucoma was more common in study eyes than controls, but was present in both. PMID:20126503

  6. Diamond knife-assisted deep anterior lamellar keratoplasty to manage keratoconus.

    PubMed

    Vajpayee, Rasik B; Maharana, Prafulla K; Sharma, Namrata; Agarwal, Tushar; Jhanji, Vishal

    2014-02-01

    To evaluate the outcomes of a new surgical technique, diamond knife-assisted deep anterior lamellar keratoplasty (DALK), and compare its visual and refractive results with big-bubble DALK in cases of keratoconus. Tertiary eyecare hospital. Comparative case series. The visual and surgical outcomes of diamond knife-assisted DALK were compared with those of successful big-bubble DALK. Diamond knife-assisted DALK was performed in 19 eyes and big-bubble DALK, in 11 eyes. All surgeries were completed successfully. No intraoperative or postoperative complications occurred with diamond knife-assisted DALK. Six months after diamond knife-assisted DALK, the mean corrected distance visual acuity (CDVA) improved significantly from 1.87 logMAR ± 0.22 (SD) to 0.23 ± 0.06 logMAR, the mean keratometry improved from 65.99 ± 8.86 diopters (D) to 45.13 ± 1.16 D, and the mean keratometric cylinder improved from 7.99 ± 3.81 D to 2.87 ± 0.59 D (all P=.005). Postoperatively, the mean refractive astigmatism was 2.55 ± 0.49 D and the mean spherical equivalent was -1.97 ± 0.56 D. The mean logMAR CDVA (P = .06), postoperative keratometry (P=.64), refractive cylinder (P=.63), and endothelial cell loss (P=.11) were comparable between diamond knife-assisted DALK and big-bubble DALK. Diamond knife-assisted DALK was effective and predictable as a surgical technique for management of keratoconus cases. This technique has the potential to offer visual and refractive outcomes comparable to those of big-bubble DALK. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Patient-specific simulation of the intrastromal ring segment implantation in corneas with keratoconus.

    PubMed

    Lago, M A; Rupérez, M J; Monserrat, C; Martínez-Martínez, F; Martínez-Sanchis, S; Larra, E; Díez-Ajenjo, M A; Peris-Martínez, C

    2015-11-01

    The purpose of this study was the simulation of the implantation of intrastromal corneal-ring segments for patients with keratoconus. The aim of the study was the prediction of the corneal curvature recovery after this intervention. Seven patients with keratoconus diagnosed and treated by implantation of intrastromal corneal-ring segments were enrolled in the study. The 3D geometry of the cornea of each patient was obtained from its specific topography and a hyperelastic model was assumed to characterize its mechanical behavior. To simulate the intervention, the intrastromal corneal-ring segments were modeled and placed at the same location at which they were placed in the surgery. The finite element method was then used to obtain a simulation of the deformation of the cornea after the ring segment insertion. Finally, the predicted curvature was compared with the real curvature after the intervention. The simulation of the ring segment insertion was validated comparing the curvature change with the data after the surgery. Results showed a flattening of the cornea which was in consonance with the real improvement of the corneal curvature. The mean difference obtained was of 0.74 mm using properties of healthy corneas. For the first time, a patient-specific model of the cornea has been used to predict the outcomes of the surgery after the intrastromal corneal-ring segments implantation in real patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Central and peripheral corneal thinning in keratoconus.

    PubMed

    Brautaset, Rune L; Nilsson, Maria; Miller, William L; Leach, Norman E; Tukler, Johanna H; Bergmanson, Jan P G

    2013-03-01

    Recent data regarding the mid-peripheral portion of the removed corneal button in transplant surgery indicate histopathologically that keratoconus was present also in the peripheral portion of the button. The intent of this study was therefore to investigate if peripheral changes could also be detected clinically by measuring the central and peripheral corneal thickness of KC patients. Corneal pachymetry was measured with the Visante optical coherence tomography and Orbscan II. Of 52 subjects, 26 were KC subjects and 26 were age- and sex-matched control subjects. Corneal thickness, in KC patients, was significantly reduced in all areas compared with corneal thickness among controls with both the Visante optical coherence tomography and Orbscan II. The results of the present study have provided clinical evidence that KC is a disease affecting a wider area of the cornea. Although the KC cornea shows the greatest change in thickness in the ectatic region, this attenuation declines toward the periphery. The presence of peripheral thinning indicated that KC may be a "pancorneal" pathology and not limited to the ectatic portion.

  9. Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Keratoconus Eyes after Accelerated Corneal Collagen Crosslinking

    PubMed Central

    Caravaca-Arens, Esteban; de Fez, Dolores; Blanes-Mompó, Francisco J.

    2017-01-01

    Purpose To analyze the errors associated to corneal power calculation using the keratometric approach in keratoconus eyes after accelerated corneal collagen crosslinking (CXL) surgery and to obtain a model for the estimation of an adjusted corneal refractive index (nkadj) minimizing such errors. Methods Potential differences (ΔPc) among keratometric (Pk) and Gaussian corneal power (PcGauss) were simulated. Three algorithms based on the use of nkadj for the estimation of an adjusted keratometric corneal power (Pkadj) were developed. The agreement between Pk(1.3375) (keratometric power using the keratometric index of 1.3375), PcGauss, and Pkadj was evaluated. The validity of the algorithm developed was investigated in 21 keratoconus eyes undergoing accelerated CXL. Results P k(1.3375) overestimated corneal power between 0.3 and 3.2 D in theoretical simulations and between 0.8 and 2.9 D in the clinical study (ΔPc). Three linear equations were defined for nkadj to be used for different ranges of r1c. In the clinical study, differences between Pkadj and PcGauss did not exceed ±0.8 D nk = 1.3375. No statistically significant differences were found between Pkadj and PcGauss (p > 0.05) and Pk(1.3375) and Pkadj (p < 0.001). Conclusions The use of the keratometric approach in keratoconus eyes after accelerated CXL can lead to significant clinical errors. These errors can be minimized with an adjusted keratometric approach. PMID:29201459

  10. Quantitative assessment of corneal vibrations during intraocular pressure measurement with the air-puff method in patients with keratoconus.

    PubMed

    Koprowski, Robert; Ambrósio, Renato

    2015-11-01

    One of the current methods for measuring intraocular pressure is the air-puff method. A tonometer which uses this method is the Corvis device. With the ultra-high-speed (UHS) Scheimpflug camera, it is also possible to observe corneal deformation during measurement. The use of modern image analysis and processing methods allows for analysis of higher harmonics of corneal deflection above 100 Hz. 493 eyes of healthy subjects and 279 eyes of patients with keratoconus were used in the measurements. For each eye, 140 corneal deformation images were recorded during intraocular pressure measurement. Each image was recorded every 230 µs and had a resolution of 200 × 576 pixels. A new, original algorithm for image analysis and processing has been proposed. It enables to separate the eyeball reaction as well as low-frequency and high-frequency corneal deformations from the eye response to an air puff. Furthermore, a method for classification of healthy subjects and patients with keratoconus based on decision trees has been proposed. The obtained results confirm the possibility to distinguish between patients with keratoconus and healthy subjects. The features used in this classification are directly related to corneal vibrations. They are only available in the proposed software and provide specificity of 98%, sensitivity-85%, and accuracy-92%. This confirms the usefulness of the proposed method in this type of classification that uses corneal vibrations during intraocular pressure measurement with the Corvis tonometer. With the new proposed algorithm for image analysis and processing allowing for the separation of individual features from a corneal deformation image, it is possible to: automatically measure corneal vibrations in a few characteristic points of the cornea, obtain fully repeatable measurement of vibrations for the same registered sequence of images and measure vibration parameters for large inter-individual variability in patients. Copyright © 2015 Elsevier

  11. Orbscan II anterior elevation changes following corneal collagen cross-linking treatment for keratoconus.

    PubMed

    Tu, Kyaw Lin; Aslanides, Ioannis M

    2009-08-01

    To analyze anterior corneal elevation changes on Orbscan II following corneal collagen cross-linking (CXL) with riboflavin. This retrospective study included 8 patients (14 eyes) with keratoconus who underwent CXL, with a mean follow-up of 7 months (range: 5 to 10 months). Pre- and postoperative (at last clinic attendance) anterior elevation difference maps were examined for overall patterns of change. On preoperative maps, distances from maximum anterior elevation to pupil center and to topographic geometric center were compared between the two patterns identified. Pre- and postoperative topography, best spectacle-corrected visual acuity (BSCVA), and refraction were also compared between the two patterns. Two patterns of anterior elevation change were visually identified: (1) paracentral steepening, no change, or flattening centrally; and (2) central steepening. The preoperative maps of eyes that manifested pattern 1 had shorter mean distances for maximum anterior elevation to pupil center (1.70 vs. 2.27 mm) and maximum anterior elevation to geometric center (1.45 vs. 1.99 mm) than those that resulted in pattern 2. Mean maximum topographic simulated keratometry decreased (P = .004) and mean irregularity indices at 3 mm (P =.03) and 5 mm (P =.04) were reduced postoperatively in pattern 1 eyes; all increased in pattern 2 eyes. Mean BSCVA improved postoperatively for both patterns. Mean preoperative myopia decreased in pattern 1 eyes by 0.44 diopters (D), whereas it increased for pattern 2 eyes by 1.83 D. Corneal shape change influenced by anisotropy of collagen distribution is a factor in the outcome of CXL treatment for keratoconus.

  12. Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Keratoconus Eyes after Accelerated Corneal Collagen Crosslinking.

    PubMed

    Piñero, David P; Camps, Vicente J; Caravaca-Arens, Esteban; de Fez, Dolores; Blanes-Mompó, Francisco J

    2017-01-01

    To analyze the errors associated to corneal power calculation using the keratometric approach in keratoconus eyes after accelerated corneal collagen crosslinking (CXL) surgery and to obtain a model for the estimation of an adjusted corneal refractive index ( n k adj ) minimizing such errors. Potential differences (Δ P c ) among keratometric ( P k ) and Gaussian corneal power ( P c Gauss ) were simulated. Three algorithms based on the use of n k adj for the estimation of an adjusted keratometric corneal power ( P k adj ) were developed. The agreement between P k (1.3375) (keratometric power using the keratometric index of 1.3375), P c Gauss , and P k adj was evaluated. The validity of the algorithm developed was investigated in 21 keratoconus eyes undergoing accelerated CXL. P k (1.3375) overestimated corneal power between 0.3 and 3.2 D in theoretical simulations and between 0.8 and 2.9 D in the clinical study (Δ P c ). Three linear equations were defined for n k adj to be used for different ranges of r 1c . In the clinical study, differences between P k adj and P c Gauss did not exceed ±0.8 D n k = 1.3375. No statistically significant differences were found between P k adj and P c Gauss ( p > 0.05) and P k (1.3375) and P k adj ( p < 0.001). The use of the keratometric approach in keratoconus eyes after accelerated CXL can lead to significant clinical errors. These errors can be minimized with an adjusted keratometric approach.

  13. Short-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.

    PubMed

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose-Manuel

    2015-01-01

    To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-point-touch fitting approach. The lens' back optic zone radius (BOZR) was 0.4mm and 0.1mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p<0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p<0.05). Significant reduction was found over time in CCA (p=0.001) and anterior corneal asphericity in both groups (p<0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p<0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p<0.05). Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apical-touch was associated with greater corneal flattening in comparison to three-point-touch lens wear. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  14. [Analysis on the role of Sirius combined topography and tomography system in screening for suspect keratoconus].

    PubMed

    Zhang, Y; Chen, Y G; Yang, H Y; Xia, Y J; Zhao, R

    2018-01-11

    Objective: To evaluate the role of Sirius combined topography and tomography system in screening for suspect keratoconus among the corneal refractive surgery candidates. Methods: Retrospective case series study. Eight hundred and sixteen consecutive ametropic patients (1 632 eyes) who underwent routine examinations before corneal refractive surgery at Peking University Third Hospital from January 2016 to September 2016 were reviewed. All the cases were analyzed with Sirius combined topography and tomography system. Fifty-nine eyes of 37 patients, aged (28.9±7.4) years, classified as suspect keratoconus by the system were enrolled in the suspect group, including 25 females (40 eyes) and 12 males (19 eyes). A random eye of the first 59 patients, aged (27.1±6.4)years, whose both eyes were classified as normal by Sirius system were enrolled in the control group, including 38 females and 21 males. The corneal anterior surface, posterior surface and minimum thickness data of the suspect group were analyzed and then compared with the control group. The classified results were further verified by Pentacam system. Independent-samples t test and Mann-Whitney U test were applied to analyze the normal distribution and non-normal distribution data respectively. Results: The medians of anterior surface and posterior surface symmetry index and Baiocchi Calossi Versaci index of anterior surface and posterior surface of the suspect group were 0.84, 0.22, 0.58 and 0.51 D, and that of the control group were 0.05, 0.04, 0.09 and 0.06 D, and the differences were of statistical significance ( Z=- 18.764, -8.351, -12.248, -10.709, P< 0.01). Mean corneal minimum thickness data of the suspect group were (504.4±30.0)μm, and that of the control group were (541.2±32.1)μm, the differences were of statistical significance ( t=- 6.408, P< 0.01). In the suspect group, the eyes related with suspect or abnormal corneal anterior indices accounted for 47.5% (28/59), the eyes related with

  15. Safety and efficacy of simultaneous corneal collagen cross-linking with topography-guided PRK in managing low-grade keratoconus: 1-year follow-up.

    PubMed

    Tuwairqi, Waleed S; Sinjab, Mazen M

    2012-05-01

    To evaluate 1-year visual and topographic outcomes and safety and efficacy of corneal collagen cross-linking (CXL) combined with topography-guided photorefractive keratectomy (TG-PRK) to achieve near emmetropia in eyes with low-grade keratoconus. Twenty-two eyes from 15 patients (11 women, 4 men) were included in a prospective, nonrandomized, noncontrolled clinical study. Mean patient age was 26.6±6.07 years (range: 19 to 40 years). Inclusion criteria were low-grade keratoconus with evidence of progression, transparent cornea, corrected distance visual acuity (CDVA) 0.8 (decimal) or better, corneal thickness >440 μm, and maximum keratometry readings (K-max) <51.00 diopters (D). All patients underwent simultaneous TG-PRK with CXL. Study parameters were uncorrected distance visual acuity, CDVA, manifest refractive error, manifest and topographic (corneal) astigmatism, patient satisfaction, and efficacy and safety of the treatment. Follow-up was 1 year. After 1 year, statistically significant improvement was noted in all study parameters (P<.01). The safety and efficacy indices were 1.6 and 0.4, respectively. Patient satisfaction questionnaire showed that 91% were satisfied, 9% were not completely satisfied but believed they improved, and none were dissatisfied. Corneal topography demonstrated significant improvement in 55%, improvement in 36%, and minor improvement in 9% of cases. No cases progressed as evidenced by keratometry readings. Simultaneous TG-PRK with CXL is an effective and safe treatment with remarkable visual and topographic outcomes in patients with low-grade keratoconus who meet the recommended inclusion criteria. Copyright 2012, SLACK Incorporated.

  16. Fourier analysis algorithm for the posterior corneal keratometric data: clinical usefulness in keratoconus.

    PubMed

    Sideroudi, Haris; Labiris, Georgios; Georgantzoglou, Kimon; Ntonti, Panagiota; Siganos, Charalambos; Kozobolis, Vassilios

    2017-07-01

    To develop an algorithm for the Fourier analysis of posterior corneal videokeratographic data and to evaluate the derived parameters in the diagnosis of Subclinical Keratoconus (SKC) and Keratoconus (KC). This was a cross-sectional, observational study that took place in the Eye Institute of Thrace, Democritus University, Greece. Eighty eyes formed the KC group, 55 eyes formed the SKC group while 50 normal eyes populated the control group. A self-developed algorithm in visual basic for Microsoft Excel performed a Fourier series harmonic analysis for the posterior corneal sagittal curvature data. The algorithm decomposed the obtained curvatures into a spherical component, regular astigmatism, asymmetry and higher order irregularities for averaged central 4 mm and for each individual ring separately (1, 2, 3 and 4 mm). The obtained values were evaluated for their diagnostic capacity using receiver operating curves (ROC). Logistic regression was attempted for the identification of a combined diagnostic model. Significant differences were detected in regular astigmatism, asymmetry and higher order irregularities among groups. For the SKC group, the parameters with high diagnostic ability (AUC > 90%) were the higher order irregularities, the asymmetry and the regular astigmatism, mainly in the corneal periphery. Higher predictive accuracy was identified using diagnostic models that combined the asymmetry, regular astigmatism and higher order irregularities in averaged 3and 4 mm area (AUC: 98.4%, Sensitivity: 91.7% and Specificity:100%). Fourier decomposition of posterior Keratometric data provides parameters with high accuracy in differentiating SKC from normal corneas and should be included in the prompt diagnosis of KC. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  17. Intracorneal ring segments implantation followed by same-day topography-guided PRK and corneal collagen CXL in low to moderate keratoconus.

    PubMed

    Al-Tuwairqi, Waleed; Sinjab, Mazen M

    2013-01-01

    To evaluate the safety and efficacy of intrastromal corneal ring segments (ICRS) implantation followed by same-day topography-guided photorefractive keratectomy (PRK) and ultraviolet-A/riboflavin collagen cross-linking (CXL) in patients with low to moderate keratoconus. Patients with low to moderate keratoconus and contact lens intolerance were included in the study. All patients first underwent femtosecond laser-enabled placement of ICRS (Keraring, Mediphacos) (first step). Same-day topography-guided PRK and CXL (second step) were subsequently performed in all patients after the refraction was stable (average 6 months [range: 3 to 11 months]). Thirteen eyes from 13 patients were included in the study. Based on values before the first step and 6 months after the second step, significant improvements were noted in uncorrected distance visual acuity (0.7±0.32 logMAR vs 0.08±0.08 logMAR), corrected distance visual acuity (CDVA) (0.16±0.19 logMAR vs 0.02±0.04 log-MAR), sphere (-3.65±3.08 diopters [D] vs 0.06±1.6 D), astigmatism (-3.31±1.5 D vs -0.98±0.75 D), average K (47.28±1.99 D vs 41.42±3.22 D), and coma (2.36±1.23 μm vs 1.47±0.68 μm) (P<.05). Approximately 63% of eyes gained ⩾2 lines of CDVA, whereas no change in CDVA was reported in ∼27% of eyes. No eyes lost lines of CDVA. The combination of ICRS implantation followed by sequential same-day topography-guided PRK/CXL may be a reasonable option for improving visual acuity in patients with low to moderate keratoconus. Copyright 2013, SLACK Incorporated.

  18. Femtosecond Intrastromal Lenticular Implantation Combined With Accelerated Collagen Cross-Linking for the Treatment of Keratoconus--Initial Clinical Result in 6 Eyes.

    PubMed

    Ganesh, Sri; Brar, Sheetal

    2015-10-01

    To evaluate the initial outcomes of femtosecond intrastromal lenticular implantation (FILI) combined with accelerated collagen cross-linking in patients with progressive keratoconus. In this interventional, prospective, exploratory case series, patients with progressive keratoconus and contact lens intolerance were included. All eyes underwent femtosecond laser-enabled placement of stromal donor tissue and simultaneous accelerated collagen cross-linking. Follow-up of patients was conducted for a mean period of 190 ± 13 days (range, 177-193 days). Six eyes from 6 patients were included in the study. Based on values before and 6 months after the procedure, clinical improvement was noted in uncorrected distance visual acuity (1.06 ± 0.48 logMAR vs. 0.38 ± 0.27 logMAR), corrected distance visual acuity (0.51 ± 0.20 logMAR vs. 0.20 ± 0.24 logMAR), and manifest spherical equivalent (-3.47 ± 1.15 D vs. -1.77 ± 1.7 D). There was flattening of mean keratometry in 3-mm and 5-mm zones by 3.42 ± 2.09 D and 1.70 ± 1.31 D, respectively. Mean pachymetry in the central and midperipheral zones increased by 18.3 ± 7.3 μm and 33.0 ± 8.8 μm, respectively. All eyes had reduction in higher-order aberrations, specifically coma. No eye lost lines of corrected distance visual acuity. No adverse events such as haze, infection, or allogeneic graft rejection were observed. Initial experience with this small number of eyes suggests that the combination of tissue addition and accelerated collagen cross-linking may be a feasible option for low to moderate keratoconus. A larger cohort and longer follow-up are required to validate our results and establish long-term safety and efficacy of the procedure.

  19. Transient corneal endothelial changes following accelerated collagen cross-linking for the treatment of progressive keratoconus.

    PubMed

    Cingü, Abdullah Kürşat; Sogutlu-Sari, Esin; Cınar, Yasin; Sahin, Muhammed; Türkçü, Fatih Mehmet; Yüksel, Harun; Sahin, Alparslan; Caça, Ihsan

    2014-06-01

    To evaluate the corneal endothelial changes following accelerated collagen cross-linking (CXL) for the treatment of progressive keratoconus. Thirty-six consecutive progressive keratoconus patients who received accelerated CXL treatment were enrolled in the study. Following de-epithelization, isoosmolar 0.1% riboflavin solution without dextran was instilled every 3 min throughout the 30 min of soaking time before the 5 min of 18 mW/cm(2) UVA irradiation and every 2 min during the UVA irradiation. Corneal specular microscopy was performed on both treated and fellow eyes of each patient preoperatively, in the first week, and in the first, third and sixth month postoperatively. There were significant differences in endothelial cell density (ECD), percentages of hexagonality (6A) and coefficient of variation of endothelial cell area (CV) in the first week and first month postoperatively in the treated eyes when compared to their preoperative values and also to the first week and first month ECD, 6A and CV values of the non-operative eyes. ECD returned to the preoperative values at sixth month whereas 6A and CV returned to the preoperative values at third month. Our results suggested that there may be transient changes in human corneal endothelium following accelerated UVA/riboflavin CXL. Resolution of these changes during the follow-up may indicate a safe recovery. However, the treatment guidelines for accelerated CXL including irradiance level and soaking time should be clearly established to minimize the toxic effects of the treatment.

  20. Topographic corneal changes after collagen cross-linking in patients with corneal keratoconus.

    PubMed

    Razmjoo, Hasan; Nasrollahi, Alireza Peyman Kobra; Salam, Hasan; Karbasi, Najmeh; Najarzadegan, Mohammad Reza

    2013-10-01

    Corneal collagen cross-linking with riboflavin, also known as collagen cross-linking (CXL), involves the application of riboflavin solution to the eye that is activated by illumination with ultraviolet A (UVA) light. We survey here the topographic corneal changes one year after CXL in patients with corneal keratoconus. This prospective randomized clinical trial study comprised 66 patients with progression of keratoconus during one year who were enrolled at Feiz University Referral Eye Center in Isfahan. Before and after the operation, patients were examined with slit lamp and funduscopic examinations and measurement of uncorrected visual acuity (UCVA), and best spectacle-corrected visual acuity (BSCVA) was done with a logarithm of minimal angle of resolution (logMAR) scale. Corneal topographic and pachymetry values were derived from Orbscan II. The paired t-test test was used for statistical analyses with SPSS software version 20 (SPSS Inc., Chicago, IL, USA). All 66 patients completed postoperative follow-up at 12 months. The mean age of the patients was 22.4 ± 5.4 years (range: 18-29 years). Thirty-six (54.55%) subjects were men and 30 (45.45%) were women. The mean preoperative sphere was -2.66 ± 2.14 diopter (D), the mean cylinder was -3.97 ± 2.29, and the mean spherical equivalent (SE) was -4.64 ± 2.56. Postoperatively, the mean sphere was -2.22 ± 2.57 D, the mean cylinder was -3.60 ± 2.40 D, and SE was -4.02 ± 2.93 D (P = 0.037). SE also demonstrated a mean difference of 0.62 ± 0.37 D significantly (P = 0.006). The mean diameter of preoperative posterior best-fit sphere (BFS) was 6.33 ± 0.35mm (range: 5.51-7.73 mm) before operation, and it improved to 6.28 ± 0.34mm (range: 4.36-6.13 mm) after operation; the difference was significant (P = 0.039). Our study showed a significant improvement in topographic corneal changes and refractive results in patients with corneal ectasia after CXL.

  1. Rose-K versus Soper contact lens in keratoconus: a randomized comparative trial.

    PubMed

    Gupta, Raghav; Sinha, Rajesh; Singh, Pooja; Sharma, Namrata; Tandon, Radhika; Titiyal, Jeewan S

    2014-01-01

    To perform a comparative evaluation of the efficacy and acceptability of Rose-K and Soper contact lenses in Keratoconus. Dr. Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi. A randomized comparative clinical trial was performed in keratoconic eyes fitted with Rose-K (Rose-K group) and Soper (Soper group) contact lenses. Patients data were evaluated for best spectacle corrected visual acuity, best contact lens corrected visual acuity (BCLCVA), corneal topography, glare acuity, contrast sensitivity, tear function tests and specular microscopy. Patients were also asked to complete a self-reported comfort questionnaire at each visit. Sixty eyes were randomized to the Rose-K and Soper groups. The two groups were comparable in all the baseline parameters. There was a statistically significant improvement in BCLCVA in both groups at 3 months (P < 0.01, both groups). The difference between in BCLCVA in both groups was not statistically significant. In both groups, there was a significant improvement in the comfort score at 3 months compared to baseline (P < 0.05, both group). The Rose-K group had statistically significantly better scores at 1 and 3 months compared with the Soper group (P = 0.006 and P < 0.001 respectively). Both groups were associated with a significant (P < 0.01), but comparable improvement in glare acuity at 3 months. There was a significant improvement in contrast sensitivity at 3 months in both groups (P < 0.01); the Rose-K group was significantly better than the Soper group at 1 and 3 months (P = 0.001 and 0.002 respectively). The mean number of trial lenses required for fitting Rose-K lens (2.00 ± 0.59) was significantly lower than the Soper lens (3.43 ± 0.82; P < 0.001). Both the contact lens designs provide an equal improvement in visual acuity in patients with Keratoconus. However, Rose-K contact lens provides greater comfort, better quality of vision and requires less chair time compared with

  2. Comparison of sequential vs same-day simultaneous collagen cross-linking and topography-guided PRK for treatment of keratoconus.

    PubMed

    Kanellopoulos, Anastasios John

    2009-09-01

    The safety and efficacy of corneal collagen cross-linking (CXL) and topography-guided photorefractive keratectomy (PRK) using a different sequence and timing were evaluated in consecutive keratoconus cases. This study included a total of 325 eyes with keratoconus. Eyes were divided into two groups. The first group (n=127 eyes) underwent CXL with subsequent topography-guided PRK performed 6 months later (sequential group) and the second group (n=198 eyes) underwent CXL and PRK in a combined procedure on the same day (simultaneous group). Statistical differences were examined for pre- to postoperative changes in uncorrected (UCVA, logMAR) and best-spectacle-corrected visual acuity (BSCVA, logMAR), manifest refraction spherical equivalent (MRSE), keratometry (K), topography, central corneal thickness, endothelial cell count, corneal haze, and ectatic progression. Mean follow-up was 36+/-18 months (range: 24 to 68 months). At last follow-up in the sequential group, the mean UCVA improved from 0.9+/-0.3 logMAR to 0.49+/-0.25 logMAR, and mean BSCVA from 0.41+/-0.25 logMAR to 0.16+/-0.22 logMAR. Mean reduction in spherical equivalent refraction was 2.50+/-1.20 diopters (D), mean haze score was 1.2+/-0.5, and mean reduction in K was 2.75+/-1.30 D. In the simultaneous group, mean UCVA improved from 0.96+/-0.2 logMAR to 0.3+/-0.2 logMAR, and mean BSCVA from 0.39+/-0.3 logMAR to 0.11+/-0.16 logMAR. Mean reduction in spherical equivalent refraction was 3.20+/-1.40 D, mean haze score was 0.5+/-0.3, and mean reduction in K was 3.50+/-1.3 D. Endothelial cell count preoperatively and at last follow-up was unchanged (P<.05) in both groups. Statistically, the simultaneous group did better (P<.05) in all fields evaluated, with improvement in UCVA and BSCVA, a greater mean reduction in spherical equivalent refraction and keratometry, and less corneal haze. Same-day simultaneous topography-guided PRK and CXL appears to be superior to sequential CXL with later PRK in the visual

  3. Effect of the Regenerative Agent Poly(Carboxymethylglucose Sulfate) on Corneal Wound Healing After Corneal Cross-Linking for Keratoconus.

    PubMed

    Kymionis, George D; Liakopoulos, Dimitrios A; Grentzelos, Michael A; Tsoulnaras, Konstantinos I; Detorakis, Efstathios T; Cochener, Béatrice; Tsilimbaris, Miltiadis K

    2015-08-01

    To evaluate the effect of a regenerative agent (RGTA) [Cacicol20-poly(carboxymethyl glucose sulfate); OTR3, Paris, France] on corneal reepithelialization and pain after corneal cross-linking (CXL) for keratoconus. In this prospective comparative (contralateral) clinical study, patients with bilateral progressive keratoconus underwent CXL treatment. The corneal epithelium during CXL was removed using transepithelial phototherapeutic keratectomy (Cretan protocol). One eye of each patient was randomly instilled with an RGTA (Cacicol20) once a day (study group), whereas the fellow eye was instilled with artificial tears (control group). Patients were examined daily until complete reepithelialization. Postoperative examinations included slit-lamp biomicroscopy to assess the epithelial defect size and subjective evaluation of pain. The study enrolled 18 patients (36 eyes). The mean epithelial defect size for study and control groups was 19.6 ± 4.2 mm versus 21.5 ± 2.8 mm, respectively, at day 1 (P = 0.019) and 6.4 ± 3.4 mm versus 7.9 ± 4.3 mm, respectively, at day 2 (P = 0.014). At day 3 postoperatively, 61.1% of study eyes were fully reepithelialized, compared with 11.1% of control eyes (P = 0.002). RGTA (Cacicol20) instillation seems to result in faster corneal reepithelialization after CXL in this study. However, there was no significant effect in subjective pain/discomfort.

  4. Topography-Guided PRK and Crosslinking in Eyes with Keratoconus and Post-LASIK Ectasia.

    PubMed

    Müller, T M; Lange, A P

    2017-04-01

    Topography-guided photorefractive keratectomy (TG-PRK) combined with corneal collagen crosslinking (CXL) has been shown to potentially improve vision and stabilize progression in patients with keratoconus (KC). We attempted to reproduce the previously published results using a different laser platform (AMARIS 500E) in patients with KC and post-LASIK ectasia (PLE). All of the 9 included eyes showed improved topography (Kmax, Kmean, RMS HOA, vertical coma, cylinder; p < 0.05) and improved visual acuity (BCVA, UCVA; p < 0.05) after 18 months. Despite some still uncontrollable factors, the combination of TG-PRK and CXL may be a promising option to regularize and stabilize corneas with KC and PLE and improve visual acuity. Georg Thieme Verlag KG Stuttgart · New York.

  5. Intacs for keratoconus and post-LASIK ectasia: mechanical versus femtosecond laser-assisted channel creation.

    PubMed

    Carrasquillo, Karen G; Rand, Janet; Talamo, Jonathan H

    2007-09-01

    To evaluate the efficacy of intracorneal ring segments to treat keratoconus and post-laser in situ keratomileusis (LASIK) keratectasia implanted by using either mechanical dissection or a femtosecond laser. Thirty-three eyes of 29 patients had intracorneal ring segments implanted by using mechanical dissection (17 eyes) or a femtosecond laser (16 eyes). Mean follow-up was 10.3 months. Parameters assessed before and after surgery included uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refractive spherical equivalent (MRSE), refractive cylinder (RC), best contact lens-corrected visual acuity (BCLVA), and contact lens tolerance. Statistically significant changes occurred for all parameters when we analyzed all 33 eyes as 1 group. Mean UCVA LogMar values improved from 1.0 +/- 0.3 (20/200) to 0.6 +/- 0.4 (20/80) (P < 0.0005). Mean BSCVA changed from 0.3 +/- 0.2 (20/40) to 0.2 +/- 0.2 (20/30) (10%; P < 0.05), and MRSE from -9 +/- 4 to -7 +/- 4 D (P < 0.05; 20%). There was a decrease of 0.5 D or more of RC in 62% of eyes. BCLVA improved from 0.2 +/- 0.2 (20/30) to 0.1 +/- 0.1 (20/25) after surgery (P < 0.02). Contact lens tolerance improved in 81% of eyes. There was no statistically significant difference in outcomes between mechanical dissection and femtosecond laser-assisted techniques. However, although statistical power was adequate to detect changes in clinical parameters as a result of surgery, it was not sufficient to conclusively show such differences between surgical techniques. For mild to moderate cases of keratoconus and post-LASIK keratectasia, the use of a femtosecond laser for Intacs channel creation seems as effective as mechanical dissection. Future studies are warranted to further evaluate channel creation by a femtosecond laser.

  6. Randomized Controlled Trial Comparing Transepithelial Corneal Cross-linking Using Iontophoresis with the Dresden Protocol in Progressive Keratoconus.

    PubMed

    Lombardo, Marco; Giannini, Daniela; Lombardo, Giuseppe; Serrao, Sebastiano

    2017-06-01

    To compare clinical outcomes of transepithelial corneal cross-linking using iontophoresis (T-ionto CL) and standard corneal cross-linking (standard CL) for the treatment of progressive keratoconus 12 months after the operation. Prospective randomized controlled clinical trial. Thirty-four eyes of 25 participants with progressive keratoconus were randomized into T-ionto CL (22 eyes) or standard CL (12 eyes). T-ionto CL was performed using an iontophoresis device with dextran-free 0.1% riboflavin-5-phosphate solution with enhancers and by irradiating the cornea with a 10 mW/cm 2 ultraviolet A device for 9 minutes. Standard CL was performed according to the Dresden protocol. The primary outcome measure was stabilization of keratoconus after 12 months through analysis of maximum simulated keratometry readings (K max , diopters). Other outcome measures were corrected distance visual acuity (CDVA, logarithm of the minimum angle of resolution [logMAR]), manifest spherical equivalent refraction (D), central corneal thickness (CCT, micrometers) and endothelial cell density (ECD). Follow-up examinations were arranged at 3 and 7 days and 1, 3, 6, and 12 months. Twelve months after T-ionto CL and standard CL, K max on average flattened by -0.52±1.30 D (P = 0.06) and -0.82±1.20 D (P = 0.04), respectively. The mean change in CDVA was -0.10±0.12 logMAR (P = 0.003) and -0.03±0.06 logMAR (P = 0.10) after T-ionto CL and standard CL, respectively. The manifest spherical equivalent refraction changed on average by +0.71±1.44 D (P = 0.03) and +0.21±0.76 D (P = 0.38), respectively. The CCT and ECD measures did not change significantly in any group at 12 months. Significant differences in the outcome measures between treatments were found in the first week postoperatively. No complications occurred in the T-ionto CL group; 1 eye (8%) had sterile corneal infiltrates, which did not affect the final visual acuity, in the standard CL group. Significant visual and

  7. Comparative study of long-term outcomes of accelerated and conventional collagen crosslinking for progressive keratoconus.

    PubMed

    Males, J J; Viswanathan, D

    2018-01-01

    PurposeTo compare the long-term outcomes of accelerated corneal collagen crosslinking (CXL) to conventional CXL for progressive keratoconus.Patients and methodsComparative clinical study of consecutive progressive keratoconic eyes that underwent either accelerated CXL (9 mW/cm 2 ultraviolet A (UVA) light irradiance for 10 min) or conventional CXL (3 mW/cm 2 UVA light irradiance for 30 min). Eyes with minimum 12 months' follow-up were included. Post-procedure changes in keratometry readings (Flat meridian: K1; steep meridian: K2), central corneal thickness (CCT), best spectacle-corrected visual acuity (BSCVA), and manifest refraction spherical equivalent (MRSE) were analysed.ResultsA total of 42 eyes were included. In all, 21 eyes had accelerated CXL (20.5±5.5 months' follow-up) and 21 eyes had conventional CXL group (20.2±5.6 months' follow-up). In the accelerated CXL group, a significant reduction in K2 (P=0.02), however no significant change in K1 (P=0.35) and CCT (P=0.62) was noted. In the conventional CXL group, a significant reduction was seen in K1 (P=0.01) and K2 (P=0.04), but not in CCT (P=0.95). Although both groups exhibited significant reductions in K2 readings, no noteworthy differences were noted between them (P=0.36). Improvements in BSCVA (accelerated CXL; P=0.22 and conventional CXL; P=0.20) and MRSE (accelerated CXL; P=0.97 and conventional CXL; P=0.54) were noted, however were not significant in either group.ConclusionAccelerated and conventional CXL appear to be effective procedures for stabilising progressive keratoconus in the long-term.

  8. Non-topography-guided PRK combined with CXL for the correction of refractive errors in patients with early stage keratoconus.

    PubMed

    Fadlallah, Ali; Dirani, Ali; Chelala, Elias; Antonios, Rafic; Cherfan, George; Jarade, Elias

    2014-10-01

    To evaluate the safety and clinical outcome of combined non-topography-guided photorefractive keratectomy (PRK) and corneal collagen cross-linking (CXL) for the treatment of mild refractive errors in patients with early stage keratoconus. A retrospective, nonrandomized study of patients with early stage keratoconus (stage 1 or 2) who underwent simultaneous non-topography-guided PRK and CXL. All patients had at least 2 years of follow-up. Data were collected preoperatively and postoperatively at the 6-month, 1-year, and 2-year follow-up visit after combined non-topography-guided PRK and CXL. Seventy-nine patients (140 eyes) were included in the study. Combined non-topography-guided PRK and CXL induced a significant improvement in both visual acuity and refraction. Uncorrected distance visual acuity significantly improved from 0.39 ± 0.22 logMAR before combined non-topography-guided PRK and CXL to 0.12 ± 0.14 logMAR at the last follow-up visit (P <.001) and corrected distance visual acuity remained stable (0.035 ± 0.062 logMAR preoperatively vs 0.036 ± 0.058 logMAR postoperatively, P =.79). The mean spherical equivalent decreased from -1.78 ± 1.43 to -0.42 ± 0.60 diopters (D) (P <.001), and the mean cylinder decreased from 1.47 ± 1.10 to 0.83 ± 0.55 D (P <.001). At the last follow-up visit mean keratometry flat was 43.30 ± 1.75 vs 45.62 ± 1.72 D preoperatively (P = .03) and mean keratometry steep was 44.39 ± 3.14 vs 46.53 ± 2.13 D preoperatively (P = .02). Mean central corneal thickness decreased from 501.74 ± 13.11 to 475.93 ± 12.25 µm following combined non-topography-guided PRK and CXL (P < .001). No intraoperative complications occurred. Four eyes developed mild haze that responded well to a short course of topical steroids. No eye developed infectious keratitis. Combined non-topography-guided PRK and CXL is an effective and safe option for correcting mild refractive error and improving visual acuity in patients with early stable keratoconus

  9. Topographic corneal changes after collagen cross-linking in patients with corneal keratoconus

    PubMed Central

    Razmjoo, Hasan; Nasrollahi, Alireza Peyman Kobra; Salam, Hasan; Karbasi, Najmeh; Najarzadegan, Mohammad Reza

    2013-01-01

    Background: Corneal collagen cross-linking with riboflavin, also known as collagen cross-linking (CXL), involves the application of riboflavin solution to the eye that is activated by illumination with ultraviolet A (UVA) light. We survey here the topographic corneal changes one year after CXL in patients with corneal keratoconus. Materials and Methods: This prospective randomized clinical trial study comprised 66 patients with progression of keratoconus during one year who were enrolled at Feiz University Referral Eye Center in Isfahan. Before and after the operation, patients were examined with slit lamp and funduscopic examinations and measurement of uncorrected visual acuity (UCVA), and best spectacle-corrected visual acuity (BSCVA) was done with a logarithm of minimal angle of resolution (logMAR) scale. Corneal topographic and pachymetry values were derived from Orbscan II. The paired t-test test was used for statistical analyses with SPSS software version 20 (SPSS Inc., Chicago, IL, USA). Results: All 66 patients completed postoperative follow-up at 12 months. The mean age of the patients was 22.4 ± 5.4 years (range: 18-29 years). Thirty-six (54.55%) subjects were men and 30 (45.45%) were women. The mean preoperative sphere was −2.66 ± 2.14 diopter (D), the mean cylinder was −3.97 ± 2.29, and the mean spherical equivalent (SE) was −4.64 ± 2.56. Postoperatively, the mean sphere was −2.22 ± 2.57 D, the mean cylinder was −3.60 ± 2.40 D, and SE was −4.02 ± 2.93 D (P = 0.037). SE also demonstrated a mean difference of 0.62 ± 0.37 D significantly (P = 0.006). The mean diameter of preoperative posterior best-fit sphere (BFS) was 6.33 ± 0.35mm (range: 5.51-7.73 mm) before operation, and it improved to 6.28 ± 0.34mm (range: 4.36-6.13 mm) after operation; the difference was significant (P = 0.039). Conclusion: Our study showed a significant improvement in topographic corneal changes and refractive results in patients with corneal ectasia after CXL

  10. Visual rehabilitation in low-moderate keratoconus: intracorneal ring segment implantation followed by same-day topography-guided photorefractive keratectomy and collagen cross linking

    PubMed Central

    Zeraid, Ferial M; Jawkhab, Asma A; Al-Tuwairqi, Waleed S; Osuagwu, Uchechukwu L

    2014-01-01

    AIM To present the results of same-day topography-guided photorefractive keratectomy (TG-PRK) and corneal collagen crosslinking (CXL) after previous intrastromal corneal ring segment (ISCR) implantation for keratoconus. METHODS An experimental clinical study on twenty-one eyes of 19 patients aged 27.1±6.6y (range 19-43y), with low to moderate keratoconus who were selected to undergo customized TG-PRK immediately followed by same-day CXL, 9mo after ISCR implantation in a university ophthalmology clinic. Refraction, uncorrected distance visual acuities (UDVA) and corrected distance visual acuities (CDVA), keratometry (K) values, central corneal thickness (CCT) and coma were assessed 3mo after TG-PRK and CXL. RESULTS After TG-PRK/CXL: the mean UDVA (logMAR) improved significantly from 0.66±0.41 to 0.20±0.25 (P<0.05); Kflat value decreased from: 48.44±3.66 D to 43.71±1.95 D; Ksteep value decreased from 45.61±2.40 D to 41.56±2.05 D; Kaverage also decreased from 47.00±2.66 D to 42.42±2.07 D (P<0.05 for all). The mean sphere and cylinder decreased significantly post-surgery from, -3.10±2.99 D to -0.11±0.93 D and from -3.68±1.53 to -1.11±0.75 D respectively, while the CDVA, CCT and coma showed no significant changes. Compared to post-ISCR, significant reductions (P<0.05 or all) in all K values, sphere and cylinder were observed after TG-PRK/CXL. CONCLUSION Same-day combined topography-guided PRK and corneal crosslinking following placement of ISCR is a safe and potentially effective option in treating low-moderate keratoconus. It significantly improves all visual acuity, reduced keratometry, sphere and astigmatism, but causes no change in central corneal thickness and coma. PMID:25349796

  11. Morphology of the Corneal Limbus Following Standard and Accelerated Corneal Collagen Cross-Linking (9 mW/cm2) for Keratoconus.

    PubMed

    Uçakhan, Ömür Ö; Bayraktutar, Betül

    2017-01-01

    To evaluate the morphological features of the corneal limbus as measured by in vivo confocal microscopy (IVCM) following standard and accelerated corneal collagen cross-linking (CXL) for keratoconus. Patients with progressive keratoconus scheduled to undergo standard CXL (group 1; 31 patients, 3 mW/cm, 370 nm, 30 minutes), or accelerated CXL (group 2; 20 patients, 9 mW/cm, 370 nm, 10 minutes) in the worse eye were included in this prospective study. Thirty eyes of 30 age-matched patients served as controls (group 3). All patient eyes underwent IVCM scanning of the central cornea and the inferior limbal area at baseline and 1, 3, and 6 months after CXL. After CXL, epithelial regrowth was complete by day 4 in both groups 1 and 2. There were no statistically significant differences between the baseline mean central corneal wing or basal cell density, limbus-palisade middle or basal cell densities of groups 1, 2, or 3. At postoperative months 1, 3, and 6, there were no statistically significant differences in either central or limbus-palisade epithelial cell densities or diameters in keratoconic eyes that underwent standard or accelerated CXL (P > 0.05). The morphology of the limbal cells was preserved as well. The morphology of limbus structures seems to be preserved following standard and accelerated CXL in short-term follow-up, as measured using IVCM.

  12. A Patient with Keratoconus, Nanophthalmos, Lipodermoids, and Pigmentary Retinopathy.

    PubMed

    Sammouh, Fady K; Baban, Tania A; Warrak, Elias L

    2016-06-01

    A 44-year-old male with no pertinent history other than poor vision for more than 25 years was examined. Best corrected visual acuity was 20/80 OD [MR: +14.25 +1.00 × 15°] and 20/200 OS [MR: +15.00 +1.50 × 175°]. Significant limitation in ocular movements and the presence of an orbital lipodermoid in the infero-temporal aspect of each eye were noted. Forced duction test was positive for the same directions of limitation indicating possible extraocular muscle fibrosis. Ophthalmoscopy was remarkable for the presence of peripheral bony spicules. Corneal topography was compatible with keratoconus (Kmax = 55.04D OD and 52.87D OS). A-scan revealed axial lengths of 16.96 mm OD and 16.32 mm OS, compatible with a diagnosis of nanophthalmos. OCT revealed diffuse macular thickening for both eyes with foveal thickness of 350 µm OD and 353 µm OS. Over the next 12 years the patient had stable visual acuity, manifest refractions and anterior segment examination. Ophthalmoscopy revealed only minimal progression of pigmentary changes. We report the first case of these simultaneous multiple findings which may refer to a possible syndromic association of congenital or early childhood onset.

  13. Changes in corneal topography and biomechanical properties after collagen cross linking for keratoconus: 1-year results.

    PubMed

    Sedaghat, Mohammadreza; Bagheri, Mansooreh; Ghavami, Shahri; Bamdad, Shahram

    2015-01-01

    To evaluate changes in corneal topography and biomechanical properties after collagen cross-linking (CXL) for progressive keratoconus. Collagen cross-linking was performed on 97 eyes. We assessed uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA). Corneal topography indices were evaluated using placido disc topography, scanning slit anterior topography (Orbscan II), and rotating Scheimpflug topography (Pentacam). Specular microscopy and corneal biomechanics were evaluated. A 1-year-follow-up results revealed that UCVA improved from 0.31 to 0.45 and BCVA changed from 0.78 to 0.84 (P < 0.001). The mean of average keratometry value decreased from 49.62 to 47.95 D (P < 0.001). Astigmatism decreased from 4.84 to 4.24 D (P < 0.001). Apex corneal thickness decreased from 458.11 to 444.46 μm. Corneal volume decreased from 56.66 to 55.97 mm(3) (P < 0.001). Posterior best fit sphere increased from 55.50 to 46.03 mm (P = 0.025). Posterior elevation increased from 99.2 to 112.22 μm (P < 0.001). Average progressive index increased from 2.26 to 2.56 (P < 0.001). A nonsignificant decrease was observed in mean endothelial count from 2996 to 2928 cell/mm(2) (P = 0.190). Endothelial coefficient of variation (CV) increased nonsignificantly from 18.26 to 20.29 (P = 0.112). Corneal hysteresis changed from 8.18 to 8.36 (P = 0.552) and corneal resistance factor increased from 6.98 to 7.21 (P = 0.202), so these changes were not significant. Visual acuity and K values improved after CXL. In spite of the nonsignificant increase in endothelial cell count and increase in the CV, CLX seems to be a safe treatment for keratoconus. Further studies with larger sample sizes and longer follow-up periods are recommended.

  14. Transepithelial corneal collagen cross-linking in keratoconus.

    PubMed

    Leccisotti, Antonio; Islam, Tahmina

    2010-12-01

    To evaluate the clinical effects of transepithelial corneal cross-linking (CXL) on keratoconic eyes pre-treated with substances enhancing epithelial permeability. Prospective, consecutive, single-masked, paired-eye study on 51 patients. The eye with more severe keratoconus was treated; the fellow eye served as the control. Gentamicin, benzalkonium chloride, and ethylenediaminetetraacetic acid were instilled for 3 hours, then oxybuprocaine for 30 minutes. Riboflavin 0.1% in 20% dextran T500 and oxybuprocaine were instilled for 30 minutes. Finally, ultraviolet A irradiation to the central 7.5 mm of the cornea was applied for 30 minutes, while riboflavin was instilled every 5 minutes. Mean corrected distance visual acuity improved by 0.036 logMAR after CXL and worsened by 0.039 logMAR in the control eyes (P<.05). Safety index was 1.05 after CXL and 0.96 in the control group. Mean spherical equivalent refraction decreased by 0.35 D (less myopic) after CXL and increased by 0.83 diopters (D) in the control eyes (P<.05). Mean apex curvature on tangential videokeratography increased by 0.51 D after CXL and by 1.61 D in the control eyes (P=.16). Mean average simulated keratometry decreased by 0.10 D after CXL and increased by 0.88 D in the control eyes (P<.05). Mean index of surface variance increased (worsened) by 0.9 after CXL and 5.3 in the control eyes (P<.05). Mean endothelial cell density was unchanged. A limited but favorable effect of transepithelial CXL was noted on keratoconic eyes, without complications. The effect appears to be less pronounced than described in the literature after CXL with de-epithelialization. Copyright 2010, SLACK Incorporated.

  15. Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus.

    PubMed

    Schedin, Staffan; Hallberg, Per; Behndig, Anders

    2016-01-20

    We propose a numerical three-dimensional (3D) ray-tracing model for the analysis of advanced corneal refractive errors. The 3D modeling was based on measured corneal elevation data by means of Scheimpflug photography. A mathematical description of the measured corneal surfaces from a keratoconus (KC) patient was used for the 3D ray tracing, based on Snell's law of refraction. A model of a commercial intraocular lens (IOL) was included in the analysis. By modifying the posterior IOL surface, it was shown that the imaging quality could be significantly improved. The RMS values were reduced by approximately 50% close to the retina, both for on- and off-axis geometries. The 3D ray-tracing model can constitute a basis for simulation of customized IOLs that are able to correct the advanced, irregular refractive errors in KC.

  16. Consanguineous Marriage as a Risk Factor for Developing Keratoconus

    PubMed Central

    JAMALI, Hossein; BEIGI, Vahid; SADEGHI-SARVESTANI, Ali

    2018-01-01

    Heredity plays an important role in keratoconus (KC). Consanguineous marriage (CM) can affect the transmission of recessively inherited conditions. We aimed to investigate the role of consanguineous marriage in the development of KC. This study included two groups: the first group comprised 415 patients who underwent surgery for KC for the first time at Khalili University Hospital (Shiraz, Iran), between 2010 and 2014; the second group comprised 415 healthy individuals who served as age- and sex-matched controls for the patient group. All study subjects were from the Fars province in Iran. CM type was evaluated by a standard checklist in both groups. The mean inbreeding coefficient (α) was evaluated and compared between the two groups. The percentage of parental first-cousin marriages was 35.4% in the patient group and 18.3% in the control group. The mean inbreeding coefficient (α) was 0.0291 in the patient group and 0.0135 in the control group. Patients with KC had a significantly higher mean inbreeding coefficient (α) than controls (T = 8, df = 828, P < 0.001). Our study suggests that CM can play a role in the pathogenesis of KC. As this disease is among the most frequent ocular disorders in our country, CM should be considered by health care systems within their screening programs. PMID:29644240

  17. Effects of eye rubbing on the levels of protease, protease activity and cytokines in tears: relevance in keratoconus.

    PubMed

    Balasubramanian, Sivaraman A; Pye, David C; Willcox, Mark D P

    2013-03-01

    Proteases, protease activity and inflammatory molecules in tears have been found to be relevant in the pathogenesis of keratoconus. We sought to determine the influence of eye rubbing on protease expression, protease activity and concentration of inflammatory molecules in tears. Basal tears were collected from normal volunteers before and after 60 seconds of experimental eye rubbing. The total amount of matrix metalloproteinase (MMP)-13 and inflammatory molecules interleukin (IL)-6 and tumour necrosis factor (TNF)-α in the tear samples were measured using specific enzyme-linked immunosorbent assays (ELISA). Tear collagenase activity was investigated using a specific activity assay. The concentrations of MMP-13 (51.9 ± 34.3 versus 63 ± 36.8 pg/ml, p = 0.006), IL-6 (1.24 ± 0.98 versus 2.02 ± 1.52 pg/ml, p = 0.004) and TNF-α (1.16 ± 0.74 versus 1.44 ± 0.66 pg/ml, p = 0.003) were significantly increased in normal subjects after eye rubbing. The experimental eye rub did not alter significantly the collagenase activity (5.02 ± 3 versus 7.50 ± 3.90 fluorescent intensity units, p = 0.14) of tears. Eye rubbing for 60 seconds increased the level of tear MMP-13, IL-6 and TNF-α in normal study subjects. This increase in protease, protease activity and inflammatory mediators in tears after eye rubbing may be exacerbated even further during persistent and forceful eye rubbing seen in people with keratoconus and this in turn may contribute to the progression of the disease. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  18. Modified big-bubble technique compared to manual dissection deep anterior lamellar keratoplasty in the treatment of keratoconus.

    PubMed

    Knutsson, Karl Anders; Rama, Paolo; Paganoni, Giorgio

    2015-08-01

    To evaluate the clinical findings and results of manual dissection deep anterior lamellar keratoplasty (DALK) compared to a modified big-bubble DALK technique in eyes affected by keratoconus. Sixty eyes of 60 patients with keratoconus were treated with one of the two surgical techniques manual DALK (n = 30); big-bubble DALK (n = 30). The main outcomes measured were visual acuity, corneal topographic parameters, thickness of residual stroma and endothelial cell density (ECD). Patients were examined postoperatively at 1 month, 6 months, 1 year and 1 month after suture removal. Final best spectacle-corrected visual acuity (BSCVA) measured 1 month after suture removal was 0.11 ± 0.08 LogMAR in the big-bubble group compared to 0.13 ± 0.08 in the manual DALK group (p = 0.227). In patients treated with the big-bubble technique without complications (Descemet's membrane completely bared), the stromal residue was not measureable. Mean stromal residual thickness in the manual DALK group was 30.50 ± 27.60 μm. Data analysis of the manual DALK group demonstrated a significant correlation between BSCVA and residual stromal thickness; lower residual stromal thickness correlated with better BSCVA values (Spearman ρ = 0.509, p = 0.018). Postoperative ECD was similar in both groups at all intervals, with no statistically significant differences. In both groups, ECD loss was only significant during the 1- to 6-month interval (p = 0.001 and p < 0.001 in the big-bubble DALK and manual DALK groups, respectively). Manual DALK provides comparable results to big-bubble DALK. Big-bubble DALK permits faster visual recovery and is a surgical technique, which can be easily converted to manual DALK in cases of unsuccessful 'big-bubble' formation. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Does lamellar surgery for keratoconus experience the popularity it deserves?

    PubMed

    Wisse, Robert P L; van den Hoven, Célinde M L; Van der Lelij, Allegonda

    2014-08-01

    To analyse developments in surgical treatment for keratoconus (KC) by assessing rates and types of corneal surgery from 2005 to 2010. The Dutch Transplantation Foundation supplied data on all keratoplasty procedures for KC performed from 2005 to 2010 in the Netherlands. Registration was carried out by the eyebank at allocation and by the surgeon at the time of surgery. The type of surgery was categorized as either a penetrating or a lamellar procedure. Five hundred and seventy-five anonymized records were received, with excellent data completion (99%). Patients undergoing penetrating surgery had on average a lower visual acuity, higher k-readings and were slightly older compared with the lamellar group. A previous corneal hydrops was recorded for 19.1% of patients. Regular penetrating keratoplasty decreased in popularity from 79.7% in 2005 to 43.7% in 2010, due to the increased rate of lamellar surgery (42.5% in 2010) and 'mushroom' penetrating keratoplasty (13.8% in 2010). When hydrops cases were excluded, popularity became equal (47.6% penetrating versus 52.4% lamellar surgery, in 2010). Lamellar surgery is gaining in popularity, although regular penetrating keratoplasty is still the more commonly performed procedure. Only when hydrops cases are excluded do transplant rates become comparable. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Graft biomechanical properties after penetrating keratoplasty in keratoconus.

    PubMed

    Feizi, Sepehr; Einollahi, Bahram; Yazdani, Shahin; Hashemloo, Ali

    2012-08-01

    To measure corneal graft biomechanical properties after penetrating keratoplasty (PKP) in a group of keratoconic eyes using the ocular response analyzer (ORA) and to evaluate the relationship between donor size, donor-recipient disparity and central graft thickness (CGT), and ORA parameters. This cross-sectional study was conducted on 34 eyes of 34 keratoconus patients who had undergone PKP. Corneal hysteresis (CH), corneal resistance factor (CRF), and cornea-compensated intraocular pressure were measured at least 6 months after complete suture removal. Two groups of donor-recipient disparity (0.25 vs. 0.50 mm) were compared using the independent t test. Multivariate regression analysis was used to investigate the correlation of donor trephine size and CGT with ORA parameters. Factors influencing intraocular pressure measured with the Goldmann applanation tonometer (IOP GAT) after PKP were determined using multiple regression analysis. Mean patient age and follow-up period were 29.6 ± 6.2 years and 82.4 ± 59.6 months, respectively. Mean CGT, CH, and CRF were 564.7 ± 36.9 μm, 10.1 ± 2.1 mm Hg, and 10.0 ± 2.3 mm Hg, respectively. CH and CRF had a significant positive correlation with donor trephine size and CGT. Significantly greater values of CH and CRF were observed in the 0.5-mm disparity group compared with the 0.25-mm disparity group. Among the studied parameters, only CH, CRF, and cornea-compensated intraocular pressure had a significant positive correlation with IOP GAT. Graft biomechanics seem to be closer to normal values with larger grafts and greater donor-recipient disparity. These metrics had a significant correlation with IOP GAT after PKP.

  1. Differential Effects of Hormones on Cellular Metabolism in Keratoconus In Vitro

    PubMed Central

    McKay, Tina B.; Hjortdal, Jesper; Sejersen, Henrik; Karamichos, Dimitrios

    2017-01-01

    Keratoconus (KC) is a corneal thinning disease with an onset commonly immediately post-puberty and stabilization by 40 to 50 years of age. The role of hormones in regulating corneal tissue structure in homeostatic and pathological conditions is unknown. Our group recently linked altered hormone levels to KC. Our current study sought to investigate and delineate the effects of exogenous hormones, such as androgen, luteotropin, and estrogen, on corneal stroma bioenergetics. We utilized our established 3D in vitro model to characterize the effects of DHEA, prolactin, 17β-estradiol on insulin-growth factor-1 and -2 (IGF-1, -2) signaling and metabolic function in primary corneal fibroblasts from healthy controls (HCFs) and KC patients (HKCs). Our data showed that exogenous DHEA significantly downregulated IGF-1 and its receptor in both HCFs and HKCs with HKCs showing consistently lower basal pentose phosphate flux. Prolactin caused no significant change in IGF-1 levels and an increase in IGF-2 in HKCs correlating with an increase in ATP and NADH levels. 17β-estradiol led to a significant upregulation in pentose phosphate flux and glycolytic intermediates in HCFs. Our results identified hormone-specific responses regulated in HKCs compared to HCFs revealing a novel role for hormones on bioenergetics in KC. PMID:28211546

  2. Wavefront-Guided Scleral Lens Correction in Keratoconus

    PubMed Central

    Marsack, Jason D.; Ravikumar, Ayeswarya; Nguyen, Chi; Ticak, Anita; Koenig, Darren E.; Elswick, James D.; Applegate, Raymond A.

    2014-01-01

    Purpose To examine the performance of state-of-the-art wavefront-guided scleral contact lenses (wfgSCLs) on a sample of keratoconic eyes, with emphasis on performance quantified with visual quality metrics; and to provide a detailed discussion of the process used to design, manufacture and evaluate wfgSCLs. Methods Fourteen eyes of 7 subjects with keratoconus were enrolled and a wfgSCL was designed for each eye. High-contrast visual acuity and visual quality metrics were used to assess the on-eye performance of the lenses. Results The wfgSCL provided statistically lower levels of both lower-order RMS (p < 0.001) and higher-order RMS (p < 0.02) than an intermediate spherical equivalent scleral contact lens. The wfgSCL provided lower levels of lower-order RMS than a normal group of well-corrected observers (p < < 0.001). However, the wfgSCL does not provide less higher-order RMS than the normal group (p = 0.41). Of the 14 eyes studied, 10 successfully reached the exit criteria, achieving residual higher-order root mean square wavefront error (HORMS) less than or within 1 SD of the levels experienced by normal, age-matched subjects. In addition, measures of visual image quality (logVSX, logNS and logLIB) for the 10 eyes were well distributed within the range of values seen in normal eyes. However, visual performance as measured by high contrast acuity did not reach normal, age-matched levels, which is in agreement with prior results associated with the acute application of wavefront correction to KC eyes. Conclusions Wavefront-guided scleral contact lenses are capable of optically compensating for the deleterious effects of higher-order aberration concomitant with the disease, and can provide visual image quality equivalent to that seen in normal eyes. Longer duration studies are needed to assess whether the visual system of the highly aberrated eye wearing a wfgSCL is capable of producing visual performance levels typical of the normal population. PMID:24830371

  3. Topography-guided transepithelial PRK after intracorneal ring segments implantation and corneal collagen CXL in a three-step procedure for keratoconus.

    PubMed

    Coskunseven, Efekan; Jankov, Mirko R; Grentzelos, Michael A; Plaka, Argyro D; Limnopoulou, Aliki N; Kymionis, George D

    2013-01-01

    To present the results of topography-guided transepithelial photorefractive keratectomy (PRK) after intracorneal ring segments implantation followed by corneal collagen cross-linking (CXL) for keratoconus. In this prospective case series, 10 patients (16 eyes) with progressive keratoconus were included. All patients underwent topography-guided transepithelial PRK after Keraring intracorneal ring segments (Mediphacos Ltda) implantation, followed by CXL treatment. The follow-up period was 6 months after the last procedure for all patients. Time interval between both intracorneal ring segments implantation and CXL and between CXL and topography-guided transepithelial PRK was 6 months. LogMAR mean uncorrected distance visual acuity and mean corrected distance visual acuity were significantly improved (P<.05) from 1.14±0.36 and 0.75±0.24 preoperatively to 0.25±0.13 and 0.13±0.06 after the completion of the three-step procedure, respectively. Mean spherical equivalent refraction was significantly reduced (P<.05) from -5.66±5.63 diopters (D) preoperatively to -0.98±2.21 D after the three-step procedure. Mean steep and flat keratometry values were significantly reduced (P<.05) from 54.65±5.80 D and 47.80±3.97 D preoperatively to 45.99±3.12 D and 44.69±3.19 D after the three-step procedure, respectively. Combined topography-guided transepithelial PRK with intracorneal ring segments implantation and CXL in a three-step procedure seems to be an effective, promising treatment sequence offering patients a functional visual acuity and ceasing progression of the ectatic disorder. A longer follow-up and larger case series are necessary to thoroughly evaluate safety, stability, and efficacy of this innovative procedure. Copyright 2013, SLACK Incorporated.

  4. [Fitting Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lenses in keratoconus patients: a prospective randomized comparative clinical trial].

    PubMed

    Coral-Ghanem, Cleusa; Alves, Milton Ruiz

    2008-01-01

    To evaluate the clinical performance of Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lens fitting in patients with keratoconus. A prospective and randomized comparative clinical trial was conducted with a minimum follow-up of six months in two groups of 63 patients. One group was fitted with Monocurve contact lenses and the other with Bicurve Soper-McGuire design. Study variables included fluoresceinic pattern of lens-to-cornea fitting relationship, location and morphology of the cone, presence and degree of punctate keratitis and other corneal surface alterations, topographic changes, visual acuity for distance corrected with contact lenses and survival analysis for remaining with the same contact lens design during the study. During the follow-up there was a decrease in the number of eyes with advanced and central cones fitted with Monocurve lenses, and an increase in those fitted with Soper-McGuire design. In the Monocurve group, a flattening of both the steepest and the flattest keratometric curve was observed. In the Soper-McGuire group, a steepening of the flattest keratometric curve and a flattening of the steepest keratometric curve were observed. There was a decrease in best-corrected visual acuity with contact lens in the Monocurve group. Survival analysis for the Monocurve lens was 60.32% and for the Soper-McGuire was 71.43% at a mean follow-up of six months. This study showed that due to the changes observed in corneal topography, the same contact lens design did not provide an ideal fitting for all patients during the follow-up period. The Soper-McGuire lenses had a better performance than the Monocurve lenses in advanced and central keratoconus.

  5. Effect of vernal keratoconjunctivitis on vitreous depth in patients with keratoconus.

    PubMed

    Cingü, Abdullah Kürşat; Kaya, Savaş; Çınar, Yasin; Şahin, Muhammed; Türkçü, Fatih Mehmet; Yüksel, Harun; Murat, Mehmet; Çaça, İhsan

    2015-05-01

    The aim of this study was to comparatively evaluate the vitreous depth (VD) of keratoconic eyes in patients with or without vernal keratoconjunctivitis (VKC). Eighty eyes of 80 consecutive keratoconus (KC) patients and 40 emmetropic control subjects were enrolled. KC patients were divided into two groups according to accompanying VKC (VKC-KC group and KC group). Mean outcome measures were best-corrected visual acuity (BCVA), spherical equivalent (SE), mean keratometry (Km), intraocular pressure (IOP), and axial length (AL) and its components. The eyes with the highest Km were selected for statistical analysis for each participant. There were 50, 30, and 40 patients in the VKC-KC group, KC group, and control group respectively. The KC group and VKC-KC group were similar in BCVA, SE, Km, CCT, ACD, LT, and IOP (p>0.05). The mean ACD was significantly lower in the control group when compared with the KC group and VKC-KC group. The mean AL and VD were significantly higher in VKC-KC group than those of KC group and the control group, whereas similar in KC and control groups (p>0.05). In the current study we showed that VKC-associated KC patients have significantly longer AL and VD when compared with KC patients without VKC. Posterior segment elongation in VKC-KC group may be associated with the type IV collagen destruction due to chronic longstanding inflammation in VKC patients.

  6. Fitting an MSD (mini scleral design) rigid contact lens in advanced keratoconus with INTACS.

    PubMed

    Dalton, Kristine; Sorbara, Luigina

    2011-12-01

    Keratoconus is a bilateral degenerative disease characterized by a non-inflammatory, progressive central corneal ectasia (typically asymmetric) and decreased vision. In its early stages it may be managed with spectacles and soft contact lenses but more commonly it is managed with rigid contact lenses. In advanced stages, when contact lenses can no longer be fit, have become intolerable, or corneal damage is severe, a penetrating keratoplasty is commonly performed. Alternative surgical techniques, such as the use of intra-stromal corneal ring segments (INTACS) have been developed to try and improve the fit of rigid contact lenses in keratoconic patients and avoid penetrating keratoplasties. This case report follows through the fitting of rigid contact lenses in an advanced keratoconic cornea after an INTACS procedure and discusses clinical findings, treatment options, and the use of mini-scleral and scleral lens designs as they relate to the challenges encountered in managing such a patient. Mini-scleral and scleral lenses are relatively easy to fit, and can be of benefit to many patients, including advanced keratoconic patients, post-INTAC patients and post-penetrating keratoplasty patients. 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Comparison of accelerated and conventional corneal collagen cross-linking for progressive keratoconus.

    PubMed

    Cınar, Yasin; Cingü, Abdullah Kürşat; Türkcü, Fatih Mehmet; Çınar, Tuba; Yüksel, Harun; Özkurt, Zeynep Gürsel; Çaça, Ihsan

    2014-09-01

    To compare outcomes of accelerated and conventional corneal cross-linking (CXL) for progressive keratoconus (KC). Patients were divided into two groups as the accelerated CXL group and the conventional CXL group. The uncorrected distant visual acuity (UDVA), corrected distant visual acuity (CDVA), refraction and keratometric values were measured preoperatively and postoperatively. The data of the two groups were compared statistically. The mean UDVA and CDVA were better at the six month postoperative when compared with preoperative values in two groups. While change in UDVA and CDVA was statistically significant in the accelerated CXL group (p = 0.035 and p = 0.047, respectively), it did not reach statistical significance in the conventional CXL group (p = 0.184 and p = 0.113, respectively). The decrease in the mean corneal power (Km) and maximum keratometric value (Kmax) were statistically significant in both groups (p = 0.012 and 0.046, respectively in the accelerated CXL group, p = 0.012 and 0.041, respectively, in the conventional CXL group). There was no statistically significant difference in visual and refractive results between the two groups (p > 0.05). Refractive and visual results of the accelerated CXL method and the conventional CXL method for the treatment of KC in short time period were similar. The accelerated CXL method faster and provide high throughput of the patients.

  8. Reliability of Entire Corneal Thickness Mapping in Normal Post-Laser in situ Keratomileusis and Keratoconus Eyes Using Long Scan Depth Spectral Domain Optical Coherence Tomography.

    PubMed

    Xu, Zhe; Chen, Sisi; Yang, Chun; Huang, Shenghai; Shen, Meixiao; Wang, Yuanyuan

    2018-01-01

    To investigate the repeatability and reproducibility of mapping the entire corneal thickness using spectral domain optical coherence tomography (SD-OCT). Thirty normal eyes, 30 post-laser in situ keratomileusis (LASIK) surgery eyes, and 30 keratoconus eyes were analyzed. A custom-built long scan depth SD-OCT device was used to obtain entire corneal images. Ten-millimeter-diameter corneal thickness maps were generated by an automated segmentation algorithm. Intraclass correlation coefficients of repeatability (ICC1) and reproducibility (ICC2), and coefficients of repeatability (CoR1) and reproducibility (CoR2), were calculated to quantify the precision and accuracy of corneal pachymetry measurements using the Bland-Altman method. For SD-OCT measurements in healthy subjects, CoR1 and CoR2 were less than 5.00 and 5.53 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in LASIK patients, CoR1 and CoR2 were less than 5.09 and 5.34 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in keratoconus patients, CoR1 and CoR2 were less than 11.57 and 10.92 μm. ICC1 and ICC2 were more than 0.995 and 0.996. The measurements of corneal pachymetric mapping by long scan depth SD-OCT can be assessed over the entire corneal area with good repeatability and reproducibility. © 2017 S. Karger AG, Basel.

  9. Characteristics of Posterior Corneal Astigmatism in Different Stages of Keratoconus.

    PubMed

    Aslani, Fereshteh; Khorrami-Nejad, Masoud; Aghazadeh Amiri, Mohammad; Hashemian, Hesam; Askarizadeh, Farshad; Khosravi, Bahram

    2018-01-01

    To evaluate the magnitudes and axis orientation of anterior corneal astigmatism (ACA) and posterior corneal astigmatism (PCA), the ratio of ACA to PCA, and the correlation between ACA and PCA in the different stages of keratoconus (KCN). This retrospective case series comprised 161 eyes of 161 patients with KCN (104 men, 57 women; mean age, 22.35 ± 6.10 years). The participants were divided into four subgroups according to the Amsler-Krumeich classification. A Scheimpflug imaging system was used to measure the magnitude and axis orientation of ACA and PCA. The posterior-anterior corneal astigmatism ratio was also calculated. The results were compared among different subgroups. The average amounts of anterior, posterior, and total corneal astigmatism were 4.08 ± 2.21 diopters (D), 0.86 ± 0.46 D, and 3.50 ± 1.94 D, respectively. With-the-rule, against-the-rule, and oblique astigmatisms of the posterior surface of the cornea were found in 61 eyes (37.9%), 67 eyes (41.6%), and 33 eyes (20.5%), respectively; corresponding figures in the anterior corneal surface were 55 eyes (32.4%), 56 eyes (34.8%), and 50 eyes (31.1%), respectively. A strong correlation ( P ≤ 0.001, r = 0.839) was found between ACA and PCA in the different stages of KCN; the correlation was weaker in eyes with grade 3 ( P ≤ 0.001, r = 0.711) and grade 4 ( P ≤ 0.001, r = 0.717) KCN. The maximum posterior-anterior corneal astigmatism ratio (PCA/ACA, 0.246) was found in patients with stage 1 KCN. Corneal astigmatism in anterior surface was more affected than posterior surface by increasing in the KCN severity, although PCA was more affected than ACA in an early stage of KCN.

  10. Eccentric small-zone ray tracing wavefront aberrometry for refraction in keratoconus.

    PubMed

    Fredriksson, Anneli; Behndig, Anders

    2016-11-01

    To compare objective refraction using small-zone eccentric laser ray tracing (LRT) wavefront aberrometry to standard autorefraction in keratoconus (KC), and whether the visual acuities achieved with these refractions differ from corresponding values in healthy eyes. Twenty-nine eyes of 29 patients with KC and 29 eyes of 29 healthy controls were included in this prospective unmasked case-control study. The uncorrected (UCVA) and spectacle-corrected (SCVA) Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuities based on refractions derived from LRT in central and four eccentric zones were compared to those achieved with standard autorefraction. The spherical equivalent (M) and two astigmatic power vectors (C0 and C45) were calculated for all refractions. Pentacam HR ® was used to generate keratometry readings of the corresponding zones. In KC, the refraction from the upper nasal zone rendered a higher SCVA than the standard autorefraction more often than in the controls (p < 0.001). There were no significant variation in M between the different LRT measurement points in the control group, but central data provided the best SCVA. The UCVA:s and SCVA:s were worse in KC, and the KC eyes showed inferior myopia and superior hyperopia. Multiple refractions rendered similar SCVA:s in KC. Pentacam HR ® showed higher keratometry readings infero-temporally, but also lower readings supero-nasally, compared to controls. In KC, eccentric LRT measurements gave better SCVA than standard autorefraction more often than in healthy eyes. Eccentric LRT may become a valuable tool in the demanding task of subjective refraction in KC. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. Evaluation of a Machine-Learning Classifier for Keratoconus Detection Based on Scheimpflug Tomography.

    PubMed

    Ruiz Hidalgo, Irene; Rodriguez, Pablo; Rozema, Jos J; Ní Dhubhghaill, Sorcha; Zakaria, Nadia; Tassignon, Marie-José; Koppen, Carina

    2016-06-01

    To evaluate the performance of a support vector machine algorithm that automatically and objectively identifies corneal patterns based on a combination of 22 parameters obtained from Pentacam measurements and to compare this method with other known keratoconus (KC) classification methods. Pentacam data from 860 eyes were included in the study and divided into 5 groups: 454 KC, 67 forme fruste (FF), 28 astigmatic, 117 after refractive surgery (PR), and 194 normal eyes (N). Twenty-two parameters were used for classification using a support vector machine algorithm developed in Weka, a machine-learning computer software. The cross-validation accuracy for 3 different classification tasks (KC vs. N, FF vs. N and all 5 groups) was calculated and compared with other known classification methods. The accuracy achieved in the KC versus N discrimination task was 98.9%, with 99.1% sensitivity and 98.5% specificity for KC detection. The accuracy in the FF versus N task was 93.1%, with 79.1% sensitivity and 97.9% specificity for the FF discrimination. Finally, for the 5-groups classification, the accuracy was 88.8%, with a weighted average sensitivity of 89.0% and specificity of 95.2%. Despite using the strictest definition for FF KC, the present study obtained comparable or better results than the single-parameter methods and indices reported in the literature. In some cases, direct comparisons with the literature were not possible because of differences in the compositions and definitions of the study groups, especially the FF KC.

  12. Enhanced Combined Tomography and Biomechanics Data for Distinguishing Forme Fruste Keratoconus.

    PubMed

    Luz, Allan; Lopes, Bernardo; Hallahan, Katie M; Valbon, Bruno; Ramos, Isaac; Faria-Correia, Fernando; Schor, Paulo; Dupps, William J; Ambrósio, Renato

    2016-07-01

    To evaluate the performance of the Ocular Response Analyzer (ORA) (Reichert Ophthalmic Instruments, Depew, NY) variables and Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) tomographic parameters in differentiating forme fruste keratoconus (FFKC) from normal corneas, and to assess a combined biomechanical and tomographic parameter to improve outcomes. Seventy-six eyes of 76 normal patients and 21 eyes of 21 patients with FFKC were included in the study. Fifteen variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior and 37 ORA waveform parameters were tested. Sixteen tomographic parameters from Pentacam HR were tested. Logistic regression was used to produce a combined biomechanical and tomography linear model. Differences between groups were assessed by the Mann-Whitney U test. The area under the receiver operating characteristics curve (AUROC) was used to compare diagnostic performance. No statistically significant differences were found in age, thinnest point, central corneal thickness, and maximum keratometry between groups. Twenty-one parameters showed significant differences between the FFKC and control groups. Among the ORA waveform measurements, the best parameters were those related to the area under the first peak, p1area1 (AUROC, 0.717 ± 0.065). Among the investigator ORA variables, a measure incorporating the pressure-deformation relationship of the entire response cycle was the best predictor (hysteresis loop area, AUROC, 0.688 ± 0.068). Among tomographic parameters, Belin/Ambrósio display showed the highest predictive value (AUROC, 0.91 ± 0.057). A combination of parameters showed the best result (AUROC, 0.953 ± 0.024) outperforming individual parameters. Tomographic and biomechanical parameters demonstrated the ability to differentiate FFKC from normal eyes. A combination of both types of information further improved predictive value. [J Refract Surg. 2016;32(7):479-485.]. Copyright

  13. A new approach based on Machine Learning for predicting corneal curvature (K1) and astigmatism in patients with keratoconus after intracorneal ring implantation.

    PubMed

    Valdés-Mas, M A; Martín-Guerrero, J D; Rupérez, M J; Pastor, F; Dualde, C; Monserrat, C; Peris-Martínez, C

    2014-08-01

    Keratoconus (KC) is the most common type of corneal ectasia. A corneal transplantation was the treatment of choice until the last decade. However, intra-corneal ring implantation has become more and more common, and it is commonly used to treat KC thus avoiding a corneal transplantation. This work proposes a new approach based on Machine Learning to predict the vision gain of KC patients after ring implantation. That vision gain is assessed by means of the corneal curvature and the astigmatism. Different models were proposed; the best results were achieved by an artificial neural network based on the Multilayer Perceptron. The error provided by the best model was 0.97D of corneal curvature and 0.93D of astigmatism. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Late onset of a persistent, deep stromal scarring after PRK and corneal cross-linking in a patient with forme fruste keratoconus.

    PubMed

    Güell, Jose L; Verdaguer, Paula; Elies, Daniel; Gris, Oscar; Manero, Felicidad

    2014-04-01

    To present a case of a late, deep stromal scar in a 22-year-old patient with forme fruste keratoconus who underwent combined corneal cross-linking and photorefractive keratectomy (PRK). Topography-guided corneal cross-linking combined with corneal PRK (without complications) was performed in both eyes with a delay of 2 weeks between each eye. At the 5-month postoperative examination of the right eye, a localized corneal haze was circumscribed to the posterior deep stroma, signifying a decrease of visual acuity. However, this improved partially and temporarily when treated with topical corticoids during 2 years of follow-up and then reoccurred, affecting the corrected distance visual acuity. To the authors' knowledge, this is the first documented, clinical case presenting a deep stromal affectation without endothelial decompensation and visual acuity affectation as a postoperative complication following topography-guided PRK and corneal cross-linking. Copyright 2014, SLACK Incorporated.

  15. Cellular Therapy With Human Autologous Adipose-Derived Adult Stem Cells for Advanced Keratoconus.

    PubMed

    Alió Del Barrio, Jorge L; El Zarif, Mona; de Miguel, María P; Azaar, Albert; Makdissy, Norman; Harb, Walid; El Achkar, Ibrahim; Arnalich-Montiel, Francisco; Alió, Jorge L

    2017-08-01

    The aim of this phase 1 study was to preliminarily evaluate the safety and efficacy of autologous adipose-derived adult stem cell (ADASC) implantation within the corneal stroma of patients with advanced keratoconus. Five consecutive patients were selected. Autologous ADASCs were obtained by elective liposuction. ADASCs (3 × 10) contained in 1 mL saline were injected into the corneal stroma through a femtosecond-assisted 9.5-mm diameter lamellar pocket under topical anesthesia. Patients were reviewed at 1 day, 1 week, 1, 3, and 6 months postoperatively. Visual function, manifest refraction, slit-lamp biomicroscopy, intraocular pressure, endothelial cell density, corneal topography, corneal optical coherence tomography, and corneal confocal biomicroscopy were recorded. No intraoperative or postoperative complications were recorded, with full corneal transparency recovery within 24 hours. Four patients completed the full follow-up. All patients improved their visual function (mean: 1 line of unaided and spectacle-corrected distance vision and 2 lines of rigid contact lens distance vision). Manifest refraction and topographic keratometry remained stable. Corneal optical coherence tomography showed a mean improvement of 16.5 μm in the central corneal thickness, and new collagen production was observed as patchy hyperreflective areas at the level of the stromal pocket. Confocal biomicroscopy confirmed the survival of the implanted stem cells at the surgical plane. Intraocular pressure and endothelial cell density remained stable. Cellular therapy of the human corneal stroma in vivo with autologous ADASCs appears to be safe. Stem cells survive in vivo with intrastromal new collagen production. Future studies with larger samples are required to confirm these preliminary results.

  16. Analysis of sphingolipids in human corneal fibroblasts from normal and keratoconus patients[S

    PubMed Central

    Qi, Hui; Priyadarsini, Shrestha; Nicholas, Sarah E.; Sarker-Nag, Akhee; Allegood, Jeremy; Chalfant, Charles E.; Mandal, Nawajes A.; Karamichos, Dimitrios

    2017-01-01

    The pathophysiology of human keratoconus (KC), a bilateral progressive corneal disease leading to protrusion of the cornea, stromal thinning, and scarring, is not well-understood. In this study, we investigated a novel sphingolipid (SPL) signaling pathway through which KC may be regulated. Using human corneal fibroblasts (HCFs) and human KC cells (HKCs), we examined the SPL pathway modulation. Both cell types were stimulated by the three transforming growth factor (TGF)-β isoforms: TGF-β1 (T1), TGF-β2 (T2), and TGF-β3 (T3). All samples were analyzed using lipidomics and real-time PCR. Our data showed that HKCs have increased levels of signaling SPLs, ceramide (Cer), and sphingosine 1-phosphate (S1P). Treatment with T1 reversed the increase in Cer in HKCs and treatment with T3 reversed the increase in S1P. S1P3 receptor mRNA levels were also significantly upregulated in HKCs, but were reduced to normal levels following T3 treatment. Furthermore, stimulation with Cer and S1P led to significant upregulation of fibrotic markers in HCFs, but not in HKCs. Additionally, stimulation with a Cer synthesis inhibitor (FTY720) led to significant downregulation of specific fibrotic markers in HKCs (TGF-β1, collagen type III, and α smooth muscle actin) without an effect on healthy HCFs, suggesting a causative role of Cer and S1P in fibrogenesis. Overall, this study suggests an association of the SPL signaling pathway in KC disease and its relation with the TGF-β pathway. PMID:28188148

  17. Outcome of Keratoconus Management: Review of the Past 20 Years' Contemporary Treatment Modalities.

    PubMed

    Mandathara, Preeji S; Stapleton, Fiona J; Willcox, Mark D P

    2017-05-01

    To describe the past 20 years' contemporary management modalities for keratoconus (KC) and their outcomes and failures and to propose recommendations in reporting their outcomes. A systematic review of the literature on KC management options for the last 20 years was performed. Original articles that reported the outcome of any form of KC management other than full-thickness or lamellar corneal graft were reviewed to collect information on their outcomes and complications and the level of scientific evidence of the study. A total of 1,147 articles retrieved and of those, 241 satisfied the inclusion criteria, and 41.1% of them were prospective case series. The higher level of evidence studies, that is, randomized controlled trials (RCTs), were limited to only one intervention, that is, corneal collagen cross-linking (CXL). However, the quality of most RCTs was limited because of performance and detection bias. Contact lenses (CLs) remain the mainstream of KC management and were associated with reversible and non-sight-threatening complications. Surgical options such as intracorneal segment implantation and phakic intraocular lens are considered in the visual rehabilitation of CL intolerants, and CXL is the only available option to stop or delay the disease progression. Generally, these surgical procedures are associated with transient inflammatory events and permanent sequelae. The published studies on KC management options varied significantly with respect to the study population, age of participants, severity of KC, clinical outcome measurements, and follow-up period. High-quality longer follow-up RCTs are required to evaluate the long-term effects of KC interventions.

  18. Measurement centration and zone diameter in anterior, posterior and total corneal astigmatism in keratoconus.

    PubMed

    Fredriksson, Anneli; Behndig, Anders

    2017-12-01

    To investigate the central and paracentral astigmatism and the significance of centration and measurement zone diameter compared to a 3-mm pupil-centred measurement zone in keratoconus and in healthy eyes. Twenty-eight right eyes from 28 KC patients with an inferotemporal cone were selected according to specified criteria based on Oculus Pentacam HR ® measurements and were matched with healthy control eyes. The flat (K1) and steep (K2) keratometry readings were registered from the 'Total Corneal Refractive Power' (TCRP) display as well as the anterior and posterior corneal astigmatism displays (ACA and PCA, respectively). Astigmatic power vectors KP0 and KP45 were calculated and analysed for a 6-mm and two 3-mm zones centred on the corneal apex and the pupil, and for 8 paracentral 3-mm zones. The astigmatism was generally higher in KC. Many astigmatic values in KC differed between the 3-mm pupil-centred and the 3- and 6-mm apex-centred zones in KC. In the controls, no corresponding differences between measurement zones were seen, apart from PCA, which differed. The magnitude and direction of KP0 and KP45 varied greatly between the paracentral measurements in KC. Centration and measurement zone diameter have great impacts on the astigmatic values in KC. A small pupil-centred measurement zone should be considered when evaluating the astigmatism in KC. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Corneal confocal microscopy following conventional, transepithelial, and accelerated corneal collagen cross-linking procedures for keratoconus.

    PubMed

    Touboul, David; Efron, Nathan; Smadja, David; Praud, Delphine; Malet, Florence; Colin, Joseph

    2012-11-01

    To compare early corneal healing following conventional, transepithelial, and accelerated corneal collagen cross-linking (CXL) protocols. Twenty-four patients with progressive keratoconus were divided into three groups to receive conventional, transepithelial, or accelerated CXL. In vivo corneal confocal microscopy was performed on each patient preoperatively and at 1, 3, and 6 months postoperatively. Closure of the epithelial wound was complete 3 days following conventional and accelerated CXL. The subbasal nerve plexus was essentially obliterated immediately following conventional and accelerated CXL, and virtually no nerve fibers had regenerated by 6 months. The anterior stroma showed significant changes 1 month following conventional CXL; these changes were similar but more pronounced following accelerated CXL. Observed stromal changes included complete obliteration of keratocytes, increased tissue reflectivity, a honeycomb-like appearance, and circular lacunae. Some recovery of keratocyte density was noted after 6 months. These changes were less pronounced in the mid-stroma, and there were no apparent changes to the posterior stroma or endothelium. The cornea appeared to be unaltered following transepithelial CXL. In vivo corneal confocal microscopy analysis of the postoperative impact of CXL on the cornea revealed clear differences among conventional, accelerated, and transepithelial CXL protocols. Accelerated CXL had a greater impact than conventional CXL on the anterior cornea, whereas transepithelial CXL did not appear to alter corneal morphology. Copyright 2012, SLACK Incorporated.

  20. Second-generation corneal deformation signal waveform analysis in normal, forme fruste keratoconic, and manifest keratoconic corneas after statistical correction for potentially confounding factors.

    PubMed

    Zhang, Lijun; Danesh, Jennifer; Tannan, Anjali; Phan, Vivian; Yu, Fei; Hamilton, D Rex

    2015-10-01

    To evaluate the difference in corneal biomechanical waveform parameters between manifest keratoconus, forme fruste keratoconus, and healthy eyes with a second-generation biomechanical waveform analyzer (Ocular Response Analyzer 2). Jules Stein Eye Institute, University of California, Los Angeles, California, USA. Retrospective chart review. The biomechanical waveform analyzer was used to obtain corneal hysteresis (CH), corneal resistance factor (CRF), and 37 biomechanical waveform parameters in manifest keratoconus eyes, forme fruste keratoconus eyes, and healthy eyes. Useful distinguishing parameters were found using t tests and a multivariable logistic regression model with stepwise variable selection. Potential confounders were controlled for. The study included 68 manifest keratoconus eyes, 64 forme fruste keratoconus eyes, and 249 healthy eyes. There was a statistical difference in the mean CRF between the normal group (10.2 mm Hg ± 1.7 [SD]) and keratoconus group (6.3 ± 1.9 mm Hg) (P = .003), and between the normal group and the forme fruste keratoconus group (7.8 ± 1.4 mm Hg) (P < .0001). There was no statistical difference in the mean CH between the normal group and the keratoconus group or the forme fruste keratoconus group. The CRF, height of peak 1 (P1) (P = .001), downslope of P1 (dslope1) (P = .027), upslope of peak 2 (P2) (P = .004), and downslope of P2 (P = .006) distinguished the normal group from the keratoconus groups. The CRF, downslope of P2 derived from upper 50% of applanation peak (P = .035), dslope1 (P = .014), and upslope of P1 (P = .008) distinguished the normal group from the forme fruste keratoconus group. Differences in multiple biomechanical waveform parameters can differentiate between healthy and diseased conditions and might improve early diagnosis of keratoconus and forme fruste keratoconus. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by

  1. Altered tear inflammatory profile in Indian keratoconus patients - The 2015 Col Rangachari Award paper

    PubMed Central

    Shetty, Rohit; Deshmukh, Rashmi; Ghosh, Arkasubhra; Sethu, Swaminathan; Jayadev, Chaitra

    2017-01-01

    Purpose: Conventionally, keratoconus (KC) has been considered a noninflammatory corneal ectatic disorder. Recent evidence suggests a possible role of inflammation in the pathogenesis of KC. Hence, we analyzed the levels of inflammatory factors in the tear fluid of Indian KC patients. Methods: Tear fluid samples were collected from age- and sex-matched healthy controls and KC patients (with different grades). The levels of the inflammatory factors in tears were analyzed using cytometric bead array (Human Soluble Protein Flex Set System, BD Biosciences) for levels of interleukin-1α (IL-1α), IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-9, IL-10, IL-12p70, IL-23p40, IL-13, IL-17A, IL-17F, IL-21, interferon-α (IFNα), IFNγ, tumor necrosis factor-α, CCL2/monocyte chemotactic protein-1, CCL4/macrophage inflammatory protein-1β (MIP-1β), MIP-1α, CCL5/RANTES, CXCL10/IP10, ICAM1, CD62E, vascular endothelial growth factor and transforming growth factor β. Results: An increase in Kmax and Kmean, and a decrease in central corneal thickness was observed with increasing grades of KC. Tear analysis showed that most of the tear soluble factors, including cytokines, chemokines, growth factors and cell adhesion molecules were significantly elevated in the KC patients compared to the controls. Conclusion: Our findings suggest that inflammatory factors associated with KC may play a role in its pathogenesis. This opens the potential to explore anti-inflammatory strategies to either halt or delay the progression of KC. PMID:29133633

  2. Distribution of ABO and Rh Blood Groups in Patients With Keratoconus: A Case-Control Study.

    PubMed

    Naderan, Mohammad; Rajabi, Mohammad Taher; Shoar, Saeed; Kamaleddin, Mohammad Amin; Naderan, Morteza; Rezagholizadeh, Farzaneh; Zolfaghari, Masoome; Pahlevani, Rozhin

    2015-07-01

    Association of keratoconus (KC) with genetic predisposition and environmental factors has been well documented. However, no single study has investigated the possible relationship between ABO and Rh blood groups and KC. A case-control study was designed in a university hospital enrolling 214 patients with KC in the case group and equal number of age- and sex-matched healthy subjects in the control group. Primary characteristics, ABO blood group, and Rh factors were compared between the two groups. Topographic findings of KC eyes and the severity of the diseases were investigated according to the distribution of the blood groups. Blood group O and Rh(+) phenotype were most frequent in both groups. There was no significant difference between the two groups in terms of ABO blood groups or Rh factors. Mean keratometery (K), central corneal thickness, thinnest corneal thickness, flat K, steep K, sphere and cylinder, spherical equivalent, and uncorrected visual acuity were all similar between ABO blood groups and Rh(+) and Rh(-) groups. However, the best spectacle-corrected visual acuity (BCVA) had the highest value in AB blood group (0.35 ± 0.22 logMAR, P=0.005). Moreover, the blood group AB revealed the highest frequency for grade 3 KC, followed by grades 1, 2, and 4 (P=0.003). We observed no significant excess of any particular blood group among KC cases compared with healthy subjects. Except BCVA, none of the keratometric or topographic findings was significantly different between blood groups.

  3. Patient-Specific Computational Modeling of Keratoconus Progression and Differential Responses to Collagen Cross-linking

    PubMed Central

    Sinha Roy, Abhijit

    2011-01-01

    Purpose. To model keratoconus (KC) progression and investigate the differential responses of central and eccentric cones to standard and alternative collagen cross-linking (CXL) patterns. Methods. Three-dimensional finite element models (FEMs) were generated with clinical tomography and IOP measurements. Graded reductions in regional corneal hyperelastic properties and thickness were imposed separately in the less affected eye of a KC patient. Topographic results, including maximum curvature and first-surface, higher-order aberrations (HOAs), were compared to those of the more affected contralateral eye. In two eyes with central and eccentric cones, a standard broad-beam CXL protocol was simulated with 200- and 300-μm treatment depths and compared to spatially graded broad-beam and cone-centered CXL simulations. Results. In a model of KC progression, maximum curvature and HOA increased as regional corneal hyperelastic properties were decreased. A topographic cone could be generated without a reduction in corneal thickness. Simulation of standard 9-mm-diameter CXL produced decreases in corneal curvature comparable to clinical reports and affected cone location. A 100-μm increase in CXL depth enhanced flattening by 24% to 34% and decreased HOA by 22% to 31%. Topographic effects were greatest with cone-centered CXL simulations. Conclusions. Progressive hyperelastic weakening of a cornea with subclinical KC produced topographic features of manifest KC. The clinical phenomenon of topographic flattening after CXL was replicated. The magnitude and higher-order optics of this response depended on IOP and the spatial distribution of stiffening relative to the cone location. Smaller diameter simulated treatments centered on the cone provided greater reductions in curvature and HOA than a standard broad-beam CXL pattern. PMID:22039252

  4. Characteristic of entire corneal topography and tomography for the detection of sub-clinical keratoconus with Zernike polynomials using Pentacam.

    PubMed

    Xu, Zhe; Li, Weibo; Jiang, Jun; Zhuang, Xiran; Chen, Wei; Peng, Mei; Wang, Jianhua; Lu, Fan; Shen, Meixiao; Wang, Yuanyuan

    2017-11-28

    The study aimed to characterize the entire corneal topography and tomography for the detection of sub-clinical keratoconus (KC) with a Zernike application method. Normal subjects (n = 147; 147 eyes), sub-clinical KC patients (n = 77; 77 eyes), and KC patients (n = 139; 139 eyes) were imaged with the Pentacam HR system. The entire corneal data of pachymetry and elevation of both the anterior and posterior surfaces were exported from the Pentacam HR software. Zernike polynomials fitting was used to quantify the 3D distribution of the corneal thickness and surface elevation. The root mean square (RMS) values for each order and the total high-order irregularity were calculated. Multimeric discriminant functions combined with individual indices were built using linear step discriminant analysis. Receiver operating characteristic curves determined the diagnostic accuracy (area under the curve, AUC). The 3rd-order RMS of the posterior surface (AUC: 0.928) obtained the highest discriminating capability in sub-clinical KC eyes. The multimeric function, which consisted of the Zernike fitting indices of corneal posterior elevation, showed the highest discriminant ability (AUC: 0.951). Indices generated from the elevation of posterior surface and thickness measurements over the entire cornea using the Zernike method based on the Pentacam HR system were able to identify very early KC.

  5. Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes.

    PubMed

    Feizi, Sepehr; Delfazayebaher, Siamak; Javadi, Mohammad Ali; Karimian, Farid; Ownagh, Vahid; Sadeghpour, Fatemeh

    2018-01-01

    To compare mean posterior corneal power and astigmatism in normal versus keratoconus affected eyes and determine the optimal cut-off points to maximize sensitivity and specificity in discriminating keratoconus from normal corneas. A total of 204 normal eyes and 142 keratoconus affected eyes were enrolled in this prospective comparative study. Mean posterior corneal power and astigmatism were measured using a dual Scheimpflug camera. Correlation coefficients were calculated to assess the relationship between the magnitudes of keratometric and posterior corneal astigmatism in the study groups. Receiver operating characteristic curves were used to compare the sensitivity and specificity of the measured parameters and to identify the optimal cut-off points for discriminating keratoconus from normal corneas. The mean posterior corneal power was -6.29 ± 0.20 D in the normal group and -7.77 ± 0.87 D in the keratoconus group ( P < 0.001). The mean magnitudes of the posterior corneal astigmatisms were -0.32 ± 0.15 D and -0.94 ± 0.39 D in the normal and keratoconus groups, respectively ( P < 0.001). Significant correlations were found between the magnitudes of keratometric and posterior corneal astigmatism in the normal (r=-0.76, P < 0.001) and keratoconus (r=-0.72, P < 0.001) groups. The mean posterior corneal power and astigmatism were highly reliable characteristics that distinguished keratoconus from normal corneas (area under the curve, 0.99 and 0.95, respectively). The optimal cut-off points of mean posterior corneal power and astigmatism were -6.70 D and -0.54 D, respectively. Mean posterior corneal power and astigmatism measured using a Galilei analyzer camera might have potential in diagnosing keratoconus. The cut-off points provided can be used for keratoconus screening.

  6. Accelerated versus conventional corneal collagen cross-linking in patients with keratoconus: an intrapatient comparative study.

    PubMed

    Sadoughi, Mohammad Mehdi; Einollahi, Bahram; Baradaran-Rafii, Alireza; Roshandel, Danial; Hasani, Hamidreza; Nazeri, Mehrdad

    2018-02-01

    To compare the outcomes of the conventional and accelerated corneal collagen cross-linking (CXL) in patients with bilateral progressive keratoconus (KC). Fifteen consecutive patients with bilateral progressive KC were enrolled. In each patient, the fellow eyes were randomly assigned to the conventional CXL (3 mW/cm 2 for 30 min) or accelerated CXL (ACXL) (9 mW/cm 2 for 10 min) groups. Manifest refraction; uncorrected and corrected distant visual acuity; maximum and mean keratometry; corneal hysteresis and corneal resistance factor; endothelial cell density and morphology; central corneal thickness; and wavefront aberrations were measured before and 12 months after the CXL. Manifest refraction spherical equivalent and refractive cylinder improved significantly only in conventional group. Uncorrected and corrected distant visual acuity did not change significantly in either group. Also there was no significant change in the maximum and mean keratometry after 12 months. There was significant decrease in central corneal thickness in both groups which was more prominent in conventional group. Endothelial cell density reduced only in the conventional group which was not statistically significant (P = 0.147). CH, CRF, and wavefront aberrations did not change significantly in either group. We did not observe any significant difference in the changes of the variables between the two groups. Accelerated CXL with 9 mW/cm 2 irradiation for 10 min had similar refractive, visual, keratometric, and aberrometric results and less adverse effects on the corneal thickness and endothelial cells as compared with the conventional method after 12 months follow-up. However, randomized clinical trials with longer follow-ups and larger sample sizes are needed.

  7. Removal and Repositioning of Intracorneal Ring Segments: Improving Corneal Topography and Clinical Outcomes in Keratoconus and Ectasia.

    PubMed

    Chan, Kahei; Hersh, Peter S

    2017-02-01

    To evaluate the efficacy of removal and relocation of intracorneal ring segments for improving outcomes in treatment of keratoconus and corneal ectasia. This is a retrospective case series conducted at a cornea and refractive surgery subspecialty practice setting. Patients with previous insertion of 2 intracorneal ring segments underwent surgical removal and repositioning of segments because of unsatisfactory visual and topographic outcomes. The principal outcomes included uncorrected and corrected visual acuities, manifest refraction, topography-derived maximum keratometry (Kmax), inferior-superior topography power difference (I - S), and higher-order aberration profile derived from wavefront analysis. Three patients are presented in this case series. Uncorrected visual acuity improved in all eyes by an average of 2.75 lines. Corrected visual acuity improved in 2 eyes and remained unchanged in 1 eye. Refractive astigmatism decreased in all patients by an average of 2.50 D. Kmax decreased by an average of 1.43 D. All patients had improvement in the I - S value with a mean decrease of 5.13 D. Topography-guided repositioning and/or replacement of corneal ring segments can result in improved topographic, optical, and visual outcomes in patients in whom the initial result is suboptimal. In these cases, a single segment repositioned beneath the cone resulted in an improved outcome. Analysis of corneal topography can guide the surgeon in treatment planning and can suggest patients in whom such an effort will be rewarded with better results.

  8. Outcomes of Corneal Cross-Linking Correlate With Cone-Specific Lysyl Oxidase Expression in Patients With Keratoconus.

    PubMed

    Shetty, Rohit; Rajiv Kumar, Nimisha; Pahuja, Natasha; Deshmukh, Rashmi; Vunnava, KrishnaPoojita; Abilash, Valsala Gopalakrishnan; Sinha Roy, Abhijit; Ghosh, Arkasubhra

    2018-03-01

    To evaluate the correlation of visual and keratometry outcomes after corneal cross-linking (CXL) in patients with keratoconus with cone epithelium-specific gene expression levels. Corneal epithelium was obtained from 35 eyes that underwent accelerated CXL (KXLII, 9 mW/cm for 10 min). Using corneal topography, epithelium over the cone and periphery was obtained separately from each subject. The ratio of gene expression for lysyl oxidase (LOX), matrix metalloproteinase 9 (MMP9), bone morphogenic protein 7, tissue inhibitor of metalloproteinase 1, collagen, type I, alpha 1, and collagen, type IV, alpha 1 (COL IVA1) from the cone and peripheral cornea was correlated with the outcome of cross-linking surgery. Patients were assessed for visual acuity, keratometry, refraction, and corneal densitometry before and 6 months after surgery. Based on the change in corneal flattening indicated by ΔKmax, the outcomes were classified as a higher response or lower response. Reduction in keratometric indices correlated with improved spherical equivalent after CXL. Preoperative levels of cone-specific LOX expression in cases with a higher response were significant (P = 0.001). COL IVA1, bone morphogenic protein 7, and tissue inhibitor of metalloproteinase 1 gene expressions were reduced in the cones of the subjects with a lower response. MMP9 levels were relatively lower in cases with a higher response compared with those with a lower response. Our study demonstrates that preoperative levels of molecular factors such as LOX, MMP9, and COL IVA1 aid in understanding CXL outcomes at the tissue level.

  9. TNF-α Genetic Predisposition and Higher Expression of Inflammatory Pathway Components in Keratoconus.

    PubMed

    Arbab, Muneeza; Tahir, Saira; Niazi, Muhammad Khizar; Ishaq, Mazhar; Hussain, Alamdar; Siddique, Pir Muhammad; Saeed, Sadia; Khan, Wajid Ali; Qamar, Raheel; Butt, Azeem Mehmood; Azam, Maleeha

    2017-07-01

    To date keratoconus (KC) pathogenesis is undefined; however, the involvement of inflammatory pathways in disease development is becoming apparent. In the present study, we investigated the role of a promoter region polymorphism rs1800629 (-308G>A) in the inflammatory pathway component TNF-α and its effects on the expression of TNF-α and downstream molecules tumor necrosis factor receptor 1 and 2 (TNFR1 and TNFR2), v-rel avian reticuloendotheliosis viral oncogene homolog A (RELA), and interleukin 6 (IL-6) in KC development. TNF-α promoter polymorphism rs1800629 (-308G>A), was genotyped in 257 sporadic KC patients and 253 healthy controls. Enzyme-linked immunosorbent assay (ELISA) was performed to assess for the -308G>A genotypes. Quantitative polymerase chain reaction (qPCR) was carried out to compare the mRNA expression of TNF-α, TNFR1, TNFR2, RELA, and IL6 in the corneal tissues of 20 KC patients and 20 donor controls. The -308G>A genotype GA was found to be significantly associated with KC development (dominant model [odds ratio (OR) = 6.67 (95% confidence interval [CI] = 4.28-10.42), P < 0.001]) and allele-A (OR = 4.30, 95%CI = 2.93-6.34, P < 0.001). TNF-α serum levels were significantly raised in patients with GA genotype (196.5 ± 69.5 pg/mL) compared to reference genotype GG (21.7 ± 8.2 pg/mL) (P < 0.0001). There was a significant overexpression of TNF-α (P = 0.002), TNFR2 (P = 0.0001), RELA (P = 0.0117), and IL6 (P = 0.0007) in the KC corneal tissues as compared to the control. The GA genotype of the TNF-α -308G>A polymorphism is a significant genetic risk factor for the pathogenesis of KC. Moreover, this single nucleotide polymorphism (SNP) was observed to be associated with deregulated expression of downstream molecules, thus further reinforcing the role of the inflammatory pathway components in the development of KC.

  10. An Evaluation of Lysyl Oxidase–Derived Cross-Linking in Keratoconus by Liquid Chromatography/Mass Spectrometry

    PubMed Central

    Takaoka, Anna; Babar, Natasha; Hogan, Julia; Kim, MiJung; Price, Marianne O.; Price, Francis W.; Trokel, Stephen L.; Paik, David C.

    2016-01-01

    Purpose Current literature contains scant information regarding the extent of enzymatic collagen cross-linking in the keratoconus (KC) cornea. The aim of the present study was to examine levels of enzymatic lysyl oxidase–derived cross-links in stromal collagen in KC tissue, and to correlate the cross-link levels with collagen fibril stability as determined by thermal denaturation temperature (Tm). Methods Surgical KC samples (n = 17) and Eye-Bank control (n = 11) corneas of age 18 to 68 years were analyzed. The samples were defatted, reduced (NaBH4), hydrolyzed (6N HCl at 110°C for 18 hours), and cellulose enriched before analysis by C8 high-performance liquid chromatography equipped with parallel fluorescent and mass detectors in selective ion monitoring mode (20 mM heptafluorobutyric acid/methanol 70:30 isocratic at 1 mL/min). Nine different cross-links were measured, and the cross-link density was determined relative to collagen content (determined colorimetrically). The Tm was determined by differential scanning calorimetry. Results Cross-links detected were dihydroxylysinonorleucine (DHLNL), hydroxylysinonorleucine, lysinonorleucine (LNL), and histidinohydroxylysinonorleucine in both control and KC samples. Higher DHLNL levels were detected in KC, whereas the dominant cross-link, LNL, was decreased in KC samples. Decreased LNL levels were observed among KC ≤ 40 corneas. There was no difference in total cross-link density between KC samples and the controls. Pyridinolines, desmosines, and pentosidine were not detected. There was no notable correlation between cross-link levels with fibril instability as determined by Tm. Conclusions Lower levels of LNL in the KC cornea suggest that there might be a cross-linking defect either in fibrillar collagen or the microfibrillar elastic network composed of fibrillin. PMID:26780316

  11. Acute hypoxia influences collagen and matrix metalloproteinase expression by human keratoconus cells in vitro.

    PubMed

    McKay, Tina B; Hjortdal, Jesper; Priyadarsini, Shrestha; Karamichos, Dimitrios

    2017-01-01

    Keratoconus (KC) is a progressive corneal ectasia linked to thinning of the central cornea. Hard contact lenses, rigid gas permeable lenses, and scleral lenses are the primary treatment modalities for early to mid- stages of KC to correct refractive error and astigmatism that develops as a result of an irregular corneal structure. These treatments are associated with significant drawbacks, including reduced availability of the tear film and oxygen to the corneal epithelium and stroma. However, it remains unknown whether hypoxia affects corneal integrity in the KC pathobiology. A number of studies have associated elevated oxidative stress with KC both in vitro and ex vivo. We hypothesized that KC-derived corneal fibroblasts are more susceptible to hypoxia-induced oxidative stress compared to healthy controls leading to exacerbation of corneal thinning in KC. This study investigated the effects of hypoxia on ECM secretion, assembly, and matrix metalloproteinase (MMP) expression in human corneal fibroblasts from healthy controls (HCFs) and KC patients (HKCs) in vitro. HCFs and HKCs were cultured in 3D constructs for 3 weeks and maintained or transferred to normoxic (21% O2) or hypoxic (2% O2) conditions, respectively, for 1 additional week. At the 4 week time-point, constructs were isolated and probed for Collagen I, III, and V, keratocan and MMP-1, -2, -3, -9, and -13, as well as hypoxia markers, hypoxia inducible factor-1α and lactoferrin. Conditioned media was also collected and probed for Collagen I, III, and V by Western blot. Thickness of the ECM assembled by HCFs and HKCs was measured using immunofluorescence microscopy. Results showed that hypoxia significantly reduced Collagen I secretion in HKCs, as well as upregulated the expression of MMP-1 and -2 with no significant effects on MMP-3, -9, or -13. ECM thickness was reduced in both cell types following 1 week in a low oxygen environment. Our study shows that hypoxia influences collagen and MMP expression by

  12. Decreased Integrity, Content, and Increased Transcript Level of Mitochondrial DNA Are Associated with Keratoconus

    PubMed Central

    Hao, Xiao-Dan; Chen, Zhao-Li; Qu, Ming-Li; Zhao, Xiao-Wen; Li, Su-Xia; Chen, Peng

    2016-01-01

    Oxidative stress may play an important role in the pathogenesis of keratoconus (KC). Mitochondrial DNA (mtDNA) is involved in mitochondrial function, and the mtDNA content, integrity, and transcript level may affect the generation of reactive oxygen species (ROS) and be involved in the pathogenesis of KC. We designed a case-control study to research the relationship between KC and mtDNA integrity, content and transcription. One-hundred ninety-eight KC corneas and 106 normal corneas from Chinese patients were studied. Quantitative real-time PCR was used to measure the relative mtDNA content, transcript levels of mtDNA and related genes. Long-extension PCR was used to detect mtDNA damage. ROS, mitochondrial membrane potential and ATP were measured by respective assay kit, and Mito-Tracker Green was used to label the mitochondria. The relative mtDNA content of KC corneas was significantly lower than that of normal corneas (P = 9.19×10−24), possibly due to decreased expression of the mitochondrial transcription factor A (TFAM) gene (P = 3.26×10−3). In contrast, the transcript levels of mtDNA genes were significantly increased in KC corneas compared with normal corneas (NADH dehydrogenase subunit 1 [ND1]: P = 1.79×10−3; cytochrome c oxidase subunit 1 [COX1]: P = 1.54×10−3; NADH dehydrogenase subunit 1, [ND6]: P = 4.62×10−3). The latter may be the result of increased expression levels of mtDNA transcription-related genes mitochondrial RNA polymerase (POLRMT) (P = 2.55×10−4) and transcription factor B2 mitochondrial (TFB2M) (P = 7.88×10−5). KC corneas also had increased mtDNA damage (P = 3.63×10−10), higher ROS levels, and lower mitochondrial membrane potential and ATP levels compared with normal corneas. Decreased integrity, content and increased transcript level of mtDNA are associated with KC. These changes may affect the generation of ROS and play a role in the pathogenesis of KC. PMID:27783701

  13. Association of Interleukin-1 Gene Single Nucleotide Polymorphisms with Keratoconus in Chinese Han Population.

    PubMed

    Wang, Yani; Wei, Wei; Zhang, Changning; Zhang, XueHui; Liu, Ming; Zhu, Xiuping; Xu, Kun

    2016-05-01

    To investigate whether interleukin-1 alpha (IL1A) and interleukin-1 beta (IL1B) polymorphisms are associated with keratoconus (KC) in unrelated Chinese Han patients. The IL1A (rs2071376) and IL1B (rs1143627, rs16944) polymorphisms were genotyped in 115 unrelated Chinese Han KC patients and 101 healthy Chinese Han volunteers with the Sequenom MassARRAY RS1000. Sequenom Typer 4.0 software, PLINK 1.07, Haploview 4.0 software platform were used to analyze the allelic variants of IL1A and IL1B genes, and their association with KC risk factors were assessed. Among the variants, the three SNPs (rs2071376 in IL1A, rs1143627 and rs16944 in the promoter region of IL1B) were different between the two groups. The A allele of rs2071376 (A > C, p = 0.017, OR = 1.968, 95% C.I. 1.313-3.425), the C allele of rs1143627 (C > T, p < 0.001, OR = 2.864, 95% C.I. 1.631-4.968) and the A allele of rs16944 (A > G, p = 0.002, OR = 2.401, 95% C.I. 1.396-4.161) were associated with a increased risk of KC in Chinese Han patients. This study showed that rs2071376, rs1143627 and rs16944 had significant differences in associations between KC patients and the control group when different genotypes were analyzed in three models (dominant, recessive, and additive). In the haplotype analysis, the two single nucleotide polymorphisms (SNPs), rs1143627 and rs16944 showed strong linkage disequilibrium. In addition, Haplotype "ACA" was found to be associated with a higher risk of developing KC (OR = 12.91, p < 0.001). Keratocyte apoptosis is an initiating event in the pathogenesis of KC which could be induced by the altered levels of IL1 gene. These findings confirmed that polymorphisms in IL1 genes were associated with risk of KC in the Chinese Han population, which help us to gain insight into the pathogenesis of KC.

  14. Reliability of Pentacam HR Thickness Maps of the Entire Cornea in Normal, Post-Laser In Situ Keratomileusis, and Keratoconus Eyes.

    PubMed

    Xu, Zhe; Peng, Mei; Jiang, Jun; Yang, Chun; Zhu, Weigen; Lu, Fan; Shen, Meixiao

    2016-02-01

    To measure the repeatability and reproducibility of Pentacam HR system thickness maps for the entire cornea in normal, post-laser in situ keratomileusis (post-LASIK), and keratoconus (KC) eyes. Reliability study. Sixty normal subjects (60 eyes), 30 post-LASIK subjects (60 eyes), and 14 KC patients (27 eyes) were imaged with the Pentacam HR system by 2 well-trained operators. For pachymetry the cornea was divided into 4 zones: a central zone (2-mm diameter) and concentric pericentral zone (2-5 mm), transitional zone (5-7 mm), and peripheral zone (7-10 mm). The 3 concentric zones were subdivided into 8 sectors. Intraobserver repeatability and interobserver reproducibility of entire corneal thickness maps were tested by the repeatability and reproducibility coefficients, intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement. From central to peripheral zones, the precision of corneal thickness measurements became gradually smaller. Central zone repeatability and reproducibility were the best in the normal, post-LASIK, and KC groups. The peripheral superior sectors showed poorer repeatability and reproducibility for all subjects. The intraobserver repeatability and interobserver reproducibility for all zones were ≤19.3 μm, ≤22.1 μm, and ≤20.7 μm, in the normal, post-LASIK, and KC groups, respectively. The intraobserver and interobserver coefficients of variation for all zones were ≤1.3%, ≤1.6%, and ≤1.6% for all 3 groups. Pentacam HR system pachymetry of the entire cornea provided good precision in normal, post-LASIK, and KC corneas. Thickness measurements in the peripheral cornea should be interpreted with caution in abnormal corneas after surgery or with diseases. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Keratoconus

    MedlinePlus

    ... condition may be due to a defect in collagen. This is the tissue that provides the shape ... the cornea so contact lenses fit better Corneal collagen cross-linking is a treatment that causes the ...

  16. Efficacy and safety of deep anterior lamellar keratoplasty vs. penetrating keratoplasty for keratoconus: a meta-analysis.

    PubMed

    Liu, Hao; Chen, Yihui; Wang, Peng; Li, Bing; Wang, Weifang; Su, Yan; Sheng, Minjie

    2015-01-01

    To evaluate difference in therapeutic outcomes between deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PKP) for the clinical treatment of keratoconus. A comprehensive search was conducted in Pubmed, EMBASE, Cochrane Library, and Web of science. Eligible studies should include at least one of the following factors: best corrected visual acuity (BCVA), postoperative spherical equivalent (SE), postoperative astigmatism and endothelial cell count (ECC), central corneal thickness (CCT), graft rejection and graft failure, of which BCVA, graft rejection and graft failure were used as the primary outcome measures, and postoperative SE, astigmatism, CCT and ECC as the secondary outcome measures. Given the lack of randomized clinical trials (RCTs), cohort studies and prospective studies were considered eligible. Sixteen clinical trials involving 6625 eyes were included in this review, including 1185 eyes in DALK group, and 5440 eyes in PKP group. The outcomes were analyzed using Cochrane Review Manager (RevMan) version 5.0 software. The postoperative BCVA in DALK group was significantly better than that in PKP group (OR = 0.48; 95%CI 0.39 to 0.60; p<0.001). There were fewer cases of graft rejection in DALK group than those in PKP group (OR = 0.28; 95%CI 0.15 to 0.50; p<0.001). Nevertheless the rate of graft failure was similar between DALK and PKP groups (OR = 1.05; 95%CI 0.81 to 1.36; p = 0.73). There were no significant differences in the secondary outcomes of SE (p = 0.70), astigmatism (p = 0.14) and CCT (p = 0.58) between DALK and PKP groups. And ECC in DALK group was significantly higher than PKP group (p<0.001). The postoperative complications, high intraocular pressure (high-IOP) and cataract were analyzed, fewer cases of complications occurred in DALK group than those in PKP group (high-IOP, OR 0.22, 95% CI 0.11-0.44, P<0.001) (cataract, OR 0.22; 95% CI 0.08-0.61, P = 0.004). And no cases of expulsive hemorrhage and endophthalmitis were

  17. Silicone hydrogel mini-scleral contact lenses in early stage after corneal collagen cross-linking for keratoconus: a retrospective case series.

    PubMed

    Severinsky, Boris; Wajnsztajn, Denise; Frucht-Pery, Joseph

    2013-11-01

     The aim was to the evaluate performance of a novel silicone hydrogel mini-scleral contact lens (SHmS) for optical correction of keratoconus in the early stages after the corneal collagen cross-linking procedure (CXL).  We retrospectively analysed the visual acuity improvement and corneal adaptation in the first 10 eyes of nine patients fitted with SHmS lenses one to 3.5 months after corneal collagen cross-linking. The lenses were designed to rest over the patients' sclera and peri-limbal cornea and vault the central cornea with minimal support over it. Visual acuities with manifest refraction and contact lenses, refractive and topographical values (Kmin and Kmax) were evaluated on lens dispensing and after six month of lens wearing. Ocular physiological responses were evaluated using the Institute of Eye Research (IER) grading scales.  SHmS fitting was performed 2.1 ± 0.97 (SD) months after collagen cross-linking. Mean follow up was 10.9 ± 4.41 months (range six to 18 months). Mean decimal visual acuity with SHmS was 0.66 ± 0.22 (approximately 6/9 Snellen fraction, range 0.3 to 0.1) or 0.75 ± 0.14 (approximately 6/8.1, range 0.5 to 1.0), when omitting two amblyopic eyes. Nine (90 per cent) eyes were successfully fitted, that is, able to wear the lenses for 10 hours per day or longer. Mean wearing time was 11.7 hours (range six to 14) per day. No corneal neovascularisation or papillary reaction was found in all fitted eyes.  SHmS contact lenses provide successful visual rehabilitation shortly after corneal collagen cross-linking. This new soft contact lens design with scleral fixation and minimal apical touch was demonstrated to be safe shortly after collagen cross-linking, as the avoidance of contact with the treated zone minimises contact lens influence on corneal recovery. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  18. Changes in astigmatism and corneal higher-order aberrations after phacoemulsification with toric intraocular lens implantation for mild keratoconus with cataract.

    PubMed

    Kamiya, Kazutaka; Shimizu, Kimiya; Miyake, Toshiyuki

    2016-07-01

    To assess the changes in astigmatism and higher-order aberrations (HOAs) after toric intraocular lens (IOL) implantation for mild non-progressive keratoconus with cataract. We prospectively examined 19 eyes of 19 consecutive keratoconic patients (mean age ± standard deviation, 63.1 ± 9.1 years) who underwent phacoemulsification with toric IOL implantation. We determined uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive astigmatism, corneal astigmatism, corneal HOAs and astigmatic axis rotation both preoperatively and 3 months postoperatively. Logarithm of the minimal angle of resolution (logMAR) UDVA was significantly improved from 1.14 ± 0.50 preoperatively to 0.46 ± 0.33 postoperatively (Wilcoxon signed-rank test, p < 0.001). LogMAR CDVA was also significantly improved from 0.27 ± 0.45 preoperatively to -0.01 ± 0.09 postoperatively (p < 0.001). In 5 of 6 eyes in which the target refraction was emmetropia, postoperative UDVA was better than 20/32. The achieved spherical equivalent correction was within ±0.5 diopters (D) of the targeted correction in 13 (68 %) eyes and 1.0 in 18 (95 %) eyes. The refractive astigmatism was significantly decreased from -1.92 ± 1.73 D preoperatively to -0.70 ± 0.60 D postoperatively (p = 0.006). The corneal astigmatism changed from 2.89 ± 1.30 D preoperatively to 2.98 ± 1.09 D postoperatively (p = 0.492), which was not statistically significant. The corneal HOAs for a 4-mm pupil was changed from 0.47 ± 0.23 µm preoperatively to 0.52 ± 0.26 µm postoperatively (p = 0.211), which was not statistically significant. According to our experience, toric IOL implantation for mild keratoconic patients having rigid gas-permeable lens intolerance appears to be effective for reducing refractive astigmatism without a significant induction of corneal HOAs.

  19. Reasons For Not Performing Keratorefractive Surgery in Patients Seeking Refractive Surgery in a Hospital-Based Cohort in “Yemen”

    PubMed Central

    Bamashmus, Mahfouth A.; Saleh, Mahmoud F.; Awadalla, Mohamed A.

    2010-01-01

    Background: To determine and analyze the reasons why keratorefractive surgery, laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) were not performed in patients who presented for refractive surgery consultation. Materials and Methods: A retrospective observational study was performed between January 2006 and December 2007 in the Yemen Magrabi Hospital. The case records of 2,091 consecutive new patients who presented for refractive surgery were reviewed. Information from the pre-operative ophthalmic examination, such as refractive error, corneal topography and visual acuity, were analyzed. The reasons for not performing LASIK and PRK in the cases that were rejected were recorded and analyzed. Results: In this cohort, 1,660 (79.4%) patients were advised to have LASIK or PRK from the 2,091 patients examined. LASIK and PRK were not advised in 431 (21%) patients. The most common reasons for not performing the surgery were high myopia >-11.00 Diopters (19%), keratoconus (18%), suboptimal central corneal thickness (15%), cataract (12%) and keratoconus suspect (forme fruste keratoconus) (10%). Conclusion: Patients who requested keratorefractive surgery have a variety of problems and warrant comprehensive attention to selection criteria on the part of the surgeon. Corneal topographies and pachymetry of refractive surgery candidates need to be read cautiously. High-refractive error, keratoconus and insufficient corneal thickness were found to be the leading reasons for not performing keratorefractive surgery in this study. PMID:21180437

  20. Comparison of Changes in Central Corneal Thickness During Corneal Collagen Cross-Linking, Using Isotonic Riboflavin Solutions With and Without Dextran, in the Treatment of Progressive Keratoconus.

    PubMed

    Zaheer, Naima; Khan, Wajid Ali; Khan, Shama; Khan, M Abdul Moqeet

    2018-03-01

    To compare intraoperative changes in central corneal thickness (CCT) during corneal cross-linking, using 2 different isotonic riboflavin solutions either with dextran or with hydroxy propyl methylcellulose, in the treatment of progressive keratoconus. In this retrospective study, we analyzed records of corneal thickness measurements, taken during various steps of cross-linking. Cross-linking was performed using either isotonic riboflavin with dextran (group A) or isotonic riboflavin with hydroxy propyl methylcellulose (without dextran) (group B). CCT measurements were recorded before and after epithelial removal, after saturation with respective isotonic riboflavin solution, after use of hypotonic riboflavin in selected cases, and after ultraviolet A (UV-A) application. A mixed-way analysis of variance was conducted on CCT readings within each group and between both groups, and p < 0.05 was considered significant. In group A (100 cases), after saturation with isotonic riboflavin, CCT was decreased by a mean of 51.4 μm (12.1%). In 64%, CCT was <400 μm and additional hypotonic riboflavin was used. After UV-A irradiation, CCT was decreased by a mean of 46.7 μm (11.4%). In group B (100 cases), after saturation with isotonic riboflavin, CCT was increased by a mean of 109.4 μm (26.1%). After UV-A exposure, CCT was increased by a mean of 59.2 μm (11.2%). There was a substantial main effect for time on CCT during corneal cross-linking (CXL), p < 0.001, within both groups. The main effect comparing CCT readings between groups A and B was also significant, p < 0.001. During cross-linking, isotonic riboflavin with dextran causes a significant decrease in corneal thickness, whereas dextran-free isotonic riboflavin causes a significant increase in corneal thickness, thus facilitating the procedure.

  1. Simulation of realistic retinoscopic measurement

    NASA Astrophysics Data System (ADS)

    Tan, Bo; Chen, Ying-Ling; Baker, K.; Lewis, J. W.; Swartz, T.; Jiang, Y.; Wang, M.

    2007-03-01

    Realistic simulation of ophthalmic measurements on normal and diseased eyes is presented. We use clinical data of ametropic and keratoconus patients to construct anatomically accurate three-dimensional eye models and simulate the measurement of a streak retinoscope with all the optical elements. The results show the clinical observations including the anomalous motion in high myopia and the scissors reflex in keratoconus. The demonstrated technique can be applied to other ophthalmic instruments and to other and more extensively abnormal eye conditions. It provides promising features for medical training and for evaluating and developing ocular instruments.

  2. Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series.

    PubMed

    Kolozsvári, Bence L; Losonczy, Gergely; Pásztor, Dorottya; Fodor, Mariann

    2017-01-13

    Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and

  3. Variants in SKP1, PROB1, and IL17B genes at keratoconus 5q31.1–q35.3 susceptibility locus identified by whole-exome sequencing

    PubMed Central

    Karolak, Justyna A; Gambin, Tomasz; Pitarque, Jose A; Molinari, Andrea; Jhangiani, Shalini; Stankiewicz, Pawel; Lupski, James R; Gajecka, Marzena

    2017-01-01

    Keratoconus (KTCN) is a protrusion and thinning of the cornea, resulting in impairment of visual function. The extreme genetic heterogeneity makes it difficult to discover factors unambiguously influencing the KTCN phenotype. In this study, we used whole-exome sequencing (WES) and Sanger sequencing to reduce the number of candidate genes at the 5q31.1–q35.3 locus and to prioritize other potentially relevant variants in an Ecuadorian family with KTCN. We applied WES in two affected KTCN individuals from the Ecuadorian family that showed a suggestive linkage between the KTCN phenotype and the 5q31.1–q35.3 locus. Putative variants identified by WES were further evaluated in this family using Sanger sequencing. Exome capture discovered a total of 173 rare (minor allele frequency <0.001 in control population) nonsynonymous variants in both affected individuals. Among them, 16 SNVs were selected for further evaluation. Segregation analysis revealed that variants c.475T>G in SKP1, c.671G>A in PROB1, and c.527G>A in IL17B in the 5q31.1–q35.3 linkage region, and c.850G>A in HKDC1 in the 10q22 locus completely segregated with the phenotype in the studied KTCN family. We demonstrate that a combination of various techniques significantly narrowed the studied genomic region and reduced the list of the putative exonic variants. Moreover, since this locus overlapped two other chromosomal regions previously recognized in distinct KTCN studies, our findings suggest that this 5q31.1–q35.3 locus might be linked with KTCN. PMID:27703147

  4. Cross-ancestry genome-wide association analysis of corneal thickness strengthens link between complex and Mendelian eye diseases.

    PubMed

    Iglesias, Adriana I; Mishra, Aniket; Vitart, Veronique; Bykhovskaya, Yelena; Höhn, René; Springelkamp, Henriët; Cuellar-Partida, Gabriel; Gharahkhani, Puya; Bailey, Jessica N Cooke; Willoughby, Colin E; Li, Xiaohui; Yazar, Seyhan; Nag, Abhishek; Khawaja, Anthony P; Polašek, Ozren; Siscovick, David; Mitchell, Paul; Tham, Yih Chung; Haines, Jonathan L; Kearns, Lisa S; Hayward, Caroline; Shi, Yuan; van Leeuwen, Elisabeth M; Taylor, Kent D; Bonnemaijer, Pieter; Rotter, Jerome I; Martin, Nicholas G; Zeller, Tanja; Mills, Richard A; Staffieri, Sandra E; Jonas, Jost B; Schmidtmann, Irene; Boutin, Thibaud; Kang, Jae H; Lucas, Sionne E M; Wong, Tien Yin; Beutel, Manfred E; Wilson, James F; Uitterlinden, André G; Vithana, Eranga N; Foster, Paul J; Hysi, Pirro G; Hewitt, Alex W; Khor, Chiea Chuen; Pasquale, Louis R; Montgomery, Grant W; Klaver, Caroline C W; Aung, Tin; Pfeiffer, Norbert; Mackey, David A; Hammond, Christopher J; Cheng, Ching-Yu; Craig, Jamie E; Rabinowitz, Yaron S; Wiggs, Janey L; Burdon, Kathryn P; van Duijn, Cornelia M; MacGregor, Stuart

    2018-05-14

    Central corneal thickness (CCT) is a highly heritable trait associated with complex eye diseases such as keratoconus and glaucoma. We perform a genome-wide association meta-analysis of CCT and identify 19 novel regions. In addition to adding support for known connective tissue-related pathways, pathway analyses uncover previously unreported gene sets. Remarkably, >20% of the CCT-loci are near or within Mendelian disorder genes. These included FBN1, ADAMTS2 and TGFB2 which associate with connective tissue disorders (Marfan, Ehlers-Danlos and Loeys-Dietz syndromes), and the LUM-DCN-KERA gene complex involved in myopia, corneal dystrophies and cornea plana. Using index CCT-increasing variants, we find a significant inverse correlation in effect sizes between CCT and keratoconus (r = -0.62, P = 5.30 × 10 -5 ) but not between CCT and primary open-angle glaucoma (r = -0.17, P = 0.2). Our findings provide evidence for shared genetic influences between CCT and keratoconus, and implicate candidate genes acting in collagen and extracellular matrix regulation.

  5. Brillouin microscopy: assessing ocular tissue biomechanics.

    PubMed

    Yun, Seok Hyun; Chernyak, Dimitri

    2018-07-01

    Assessment of corneal biomechanics has been an unmet clinical need in ophthalmology for many years. Many researchers and clinicians have identified corneal biomechanics as source of variability in refractive procedures and one of the main factors in keratoconus. However, it has been difficult to accurately characterize corneal biomechanics in patients. The recent development of Brillouin light scattering microscopy heightens the promise of bringing biomechanics into the clinic. The aim of this review is to overview the progress and discuss prospective applications of this new technology. Brillouin microscopy uses a low-power near-infrared laser beam to determine longitudinal modulus or mechanical compressibility of tissue by analyzing the return signal spectrum. Human clinical studies have demonstrated significant difference in the elastic properties of normal corneas versus corneas diagnosed with mild and severe keratoconus. Clinical data have also shown biomechanical changes after corneal cross-linking treatment of keratoconus patients. Brillouin measurements of the crystalline lens and sclera have also been demonstrated. Brillouin microscopy is a promising technology under commercial development at present. The technique enables physicians to characterize the biomechanical properties of ocular tissues.

  6. Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking

    PubMed Central

    Hassan, Ziad; Modis, Laszlo; Szalai, Eszter; Berta, Andras; Nemeth, Gabor

    2014-01-01

    AIM To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus. METHODS Collagen cross-linking was performed in 31 eyes of 31 keratoconus patients (mean age 30.6±8.9y). Prior to treatment and an average 7mo after therapy, Scheimpflug analysis was performed using Pentacam HR. In addition to corneal thickness assessments, corneal radius, elevation, and aberrometric measurements were performed both on anterior and posterior corneal surfaces. Data obtained before and after surgery were statistically analyzed. RESULTS In terms of horizontal and vertical corneal radius, and central corneal thickness no deviations were observed an average 7mo after operation. Corneal higher order aberration showed no difference neither on anterior nor on posterior corneal surfaces. During follow-up period, no significant deviation was detected regarding elevation values obtained by measurement in mm units between the 3.0-8.0 mm-zones. CONCLUSION Corneal stabilization could be observed in terms of anterior and posterior corneal surfaces, elevation and higher order aberration values 7mo after collagen cross-linking therapy for keratoconus. PMID:24790876

  7. [Complications and postoperative therapeutic strategies in cross-linking].

    PubMed

    Kohlhaas, M

    2017-08-01

    The reduced corneal mechanical stability in keratoconus and similar collagen diseases can lead to a progressive and irregular corneal shape and decrease of visual acuity. A progression of keratectatic diseases can be shown with corneal topography. Keratoconus can be treated by photo-oxidative cross-linking of the corneal collagen. In order to achieve a high absorption of irradiation energy in the cornea, riboflavin at a concentration of 0.1% and UVA light at a wavelength of 370 nm corresponding to the relative maximum absorption of riboflavin (vitamin B2) are used. Evidence for corneal cross-linking are the increase of biomechanical stiffness, the increased resistance against enzymatic degradation, a higher shrinkage temperature, a lower swelling rate and an increased diameter of collagen fibers. The currently available data demonstrate that the therapeutic cross-linking procedure is safe when respecting the important theoretical and clinical parameters and that a progression of the keratoconus can be avoided. In 80% of cases an average levelling of the curvature of approximately 2 dpt can be achieved, which leads not only to stabilization but also to an increase in visual acuity of approximately 1.2 lines. In a Cochrane review from 2015 publications about complications and results were reviewed. Complication rates ranged from 1-10% depending on the initial situation, comorbidities and stage of the keratoconus. The most important complications are early epithelial wound healing problems as well as extremely rare perforations. Corneal cross-linking is a well-established and safe procedure but is not free of complications.

  8. Imaging of Keratoconic and normal human cornea with a Brillouin imaging system (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Besner, Sebastien; Shao, Peng; Scarcelli, Giuliano; Pineda, Roberto; Yun, Seok-Hyun (Andy)

    2016-03-01

    Keratoconus is a degenerative disorder of the eye characterized by human cornea thinning and morphological change to a more conical shape. Current diagnosis of this disease relies on topographic imaging of the cornea. Early and differential diagnosis is difficult. In keratoconus, mechanical properties are found to be compromised. A clinically available invasive technique capable of measuring the mechanical properties of the cornea is of significant importance for understanding the mechanism of keratoconus development and improve detection and intervention in keratoconus. The capability of Brillouin imaging to detect local longitudinal modulus in human cornea has been demonstrated previously. We report our non-contact, non-invasive, clinically viable Brillouin imaging system engineered to evaluate mechanical properties human cornea in vivo. The system takes advantage of a highly dispersive 2-stage virtually imaged phased array (VIPA) to detect weak Brillouin scattering signal from biological samples. With a 1.5-mW light beam from a 780-nm single-wavelength laser source, the system is able to detect Brillouin frequency shift of a single point in human cornea less than 0.3 second, at a 5μm/30μm lateral/axial resolution. Sensitivity of the system was quantified to be ~ 10 MHz. A-scans at different sample locations on a human cornea with a motorized human interface. We imaged both normal and keratoconic human corneas with this system. Whereas no significantly difference were observed outside keratocnic cones compared with normal cornea, a highly statistically significantly decrease was found in the cone regions.

  9. Corneal transplantation trends in France from 2004 to 2015: A 12-year review.

    PubMed

    Bigan, Guillaume; Puyraveau, Marc; Saleh, Maher; Gain, Philippe; Martinache, Isabelle; Delbosc, Bernard; Gauthier, Anne-Sophie

    2018-04-01

    The aim of this study was to report the 12-year longitudinal trends in indication and corneal transplantation techniques in France from 2004 to 2015. The records of all corneal transplantations performed from 2004 to 2015 in France were retrospectively reviewed. The patient indications and types of transplant performed were analyzed. A total of 46,658 corneal transplantations were performed between 2004 and 2015, with 34,187 (73.3%) penetrating keratoplasty and 10,452 (22.4%) lamellar keratoplasty. The leading surgical indications were secondary endothelial failure (24.3%), keratoconus (18.8%), regraft (13.5%), and Fuchs endothelial corneal dystrophy (15.1%). Endothelial keratoplasty became the preferred technique for endothelial diseases and deep anterior lamellar keratoplasty the preferred technique for keratoconus, surpassing penetrating keratoplasty in 2013. Secondary endothelial failure is the top indication for performing a keratoplasty over the 12-year period. There was a shift from penetrating keratoplasty to endothelial keratoplasty performed for Fuchs endothelial corneal dystrophy and secondary endothelial failure, and to deep anterior lamellar keratoplasty, performed for keratoconus. This highlights an important shift in managing corneal diseases toward the application of selective and more conservative surgeries and changes in indications in corneal transplantation.

  10. The influence of rigid gas permeable lens wear on the concentrations of dinucleotides in tears and the effect on dry eye signs and symptoms in keratoconus.

    PubMed

    Carracedo, Gonzalo; González-Méijome, José Manuel; Martín-Gil, Alba; Carballo, Jesús; Pintor, Jesús

    2016-10-01

    To evaluate the signs and symptoms of dry eye and dinucleotide secretion in tears of keratoconus patients (KC) and the potential effect of rigid gas permeable (RGP) contact lens wear. Twenty-three KC patients and forty control subjects were enrolled in this study. Signs of dry eye including tear volume, tear stability and corneal staining along with symptoms were assessed using the McMonnies questionnaire. Tears were collected using Schirmer strips, and dinucleotide concentrations in collected tears measured using high pressure liquid chromatography. Values obtained in KC and controls were compared. The effect of contact lens wear in KC was also assessed. KC eyes showed a significantly lower tear volume compared to controls, shorter tear break up time (TBUT), higher corneal staining and higher McMonnies dry eye questionnaire scores (p<0.05). When compared with non-wearers, KC contact lens wearers showed significantly higher symptoms, lower Schirmer and TBUT values (p<0.05). Concentration of Ap4A (0.695±0.304μM vs. 0.185±0.178μM) and Ap5A (0.132±0.128μM vs. 0.045±0.036μM) were higher in KC compared to controls (p<0.001) and only Ap4A was statistically higher in RGP wearers compared to non-wearers (0.794±0.478μM vs. 0.417±0.313μM) (p<0.05). Signs and symptoms of dry eye as well as concentrations of Ap4A and Ap5A were markedly increased in KC patients compared to controls. Moreover, Ap4A and symptoms of dry eye were statistically higher in RGP wearers compared to non-wearers. This seems to indicate that factors such as RGP contact lens wear might exacerbate the clinical condition of dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  11. Pharmaceutical Approval Update.

    PubMed

    Kaufman, Michele B

    2016-08-01

    Venetoclax (Venclexta) for chronic lymphocytic leukemia; riboflavin 5'-phosphate solutions (Photrexa Viscous and Photrexa) for progressive keratoconus; and pimavanserin (Nuplazid) for Parkinson's disease psychosis.

  12. The cornea in connective tissue diseases.

    PubMed

    Maumenee, I H

    1978-10-01

    Even though lenticular and retinal abnormalities seem to dominate the ophthalmologic picture in Marfan's syndrome, the cornea shows significant abnormalities consisting of a striking flattening and corneal astigmatism. The use of conjunctival biopsies followed by histochemical and electron-microscopic evaluation shows low morbidity but an excellent yield of diagnostic information on storage diseases, and an ectopic collagen may be the basis of at least one type of keratoconus. Much more work has to be done on defining the collagens of the human eye in embryologic, fetal, and postnatal stages under normal and pathologic conditions. The yield of such studies may be high for an understanding of such diseases as myopia, retinal detachment, and keratoconus.

  13. Corneal collagen cross-linking in the stabilization of PRK, LASIK, thermal keratoplasty, and orthokeratology.

    PubMed

    Nguyen, Michelle K; Chuck, Roy S

    2013-07-01

    To describe the use of corneal collagen cross-linking (CXL) and its efficacy in the stabilization of keratorefractive procedures, including PRK, laser in-situ keratomileusis (LASIK), thermal keratoplasty, and orthokeratology. Since its introduction, CXL has quickly gained interest in the treatment of ectactic disorders due to its ability to increase the biomechanical stability of the cornea. In its earliest use, it has shown to be effective in the treatment of both keratoconus and post-LASIK ectasia. More recent studies of CXL in combination with keratorefractive procedures have shown varying degrees of success. CXL with PRK has shown to be effective in slowing or halting the progression of keratoconus, pellucid marginal degeneration, and post-LASIK ectasia, in addition to potentially decreasing or delaying the need for penetrating keratoplasty. Several small case series have also demonstrated improved stability and efficacy of PRK and LASIK when combined with CXL, as well as a potentially decreased risk of postprocedure ectasia. In conjunction with thermokeratoplasty and orthokeratology, CXL has shown improved but only temporary results in the treatment of keratoconus. Future studies are needed to determine the efficacy and long-term stability of CXL in combination with keratorefractive procedures, as well as to address possible complications.

  14. A Review of Collagen Cross-Linking in Cornea and Sclera

    PubMed Central

    Zhang, Xiao; Tao, Xiang-chen; Zhang, Jian; Li, Zhi-wei; Xu, Yan-yun; Wang, Yu-meng; Zhang, Chun-xiao; Mu, Guo-ying

    2015-01-01

    Riboflavin/UVA cross-linking is a technique introduced in the past decades for the treatment of keratoconus, keratectasia, and infectious keratitis. Its efficacy and safety have been investigated with clinical and laboratory studies since its first clinical application by Wollensak for the treatment of keratoconus. Although its complications are encountered during clinical practice, such as infection inducing risk, minimal invasion merits a further investigation on its future application in clinical practice. Recently, collagen cross-linking in sclera shows a promising prospect. In present study, we summarized the representative studies describing the clinical and laboratory application of collagen cross-linking published in past decades and provided our opinion on the positive and negative results of cross-linking in the treatment of ophthalmic disorders. PMID:25922758

  15. Determination of corneal elasticity coefficient using the ORA database.

    PubMed

    Avetisov, Sergei E; Novikov, Ivan A; Bubnova, Irina A; Antonov, Alexei A; Siplivyi, Vladimir I

    2010-07-01

    To propose a new approach for the study of corneal biomechanics using the Reichert Ocular Response Analyzer (ORA) database, which is based on changes in velocity retardation in the central cornea at the peak of flattening. The ORA applanation curve was analyzed using a mathematical technique, which allowed calculation of the elasticity coefficient (Ke), which is primarily characteristic of the elastic properties of the cornea. Elasticity coefficient values were obtained in patients with presumably different biomechanical properties of the cornea: "normal" cornea (71 eyes, normal group), keratoconus (34 eyes, keratoconus group), LASIK (36 eyes, LASIK group), and glaucoma with elevated and compensated intraocular pressure (lOP) (38 eyes, glaucoma group). The mean Ke value in the normal group was 11.05 +/- 1.6, and the corneal thickness correlation coefficient r2 was 0.48. In the keratoconus group, the mean Ke value was 4.91 +/- 1.87 and the corneal thickness correlation coefficient r2 was 0.47. In the LASIK group, Ke and r2 were 5.99 +/- 1.18 and 0.39, respectively. In the glaucoma group, the same eyes that experienced a two-fold reduction in lOP developed a statistically significant reduction in the Ke (1.06 times lower), whereas their corneal hysteresis value increased 1.25 times. The elasticity coefficient calculated using the ORA applanation curve can be used in the evaluation of corneal biomechanical properties.

  16. Thick keratoconic cornea associated with posterior polymorphous corneal dystrophy.

    PubMed

    Zaarour, K; Slim, E; Antoun, J; Waked, N

    2017-03-01

    We herein report a case of bilateral unusually thick non-edematous keratoconic corneas with associated endothelial features of posterior polymorphous corneal dystrophy (PPCD). We report the case of a 27-year-old myopic woman who presented for refractive surgery. Slit lamp exam showed bilateral corneal protrusion with diffuse deep stromal and endothelial vesicular opacities and small paracentral bands. Topography showed generalized advanced corneal steepening in both eyes with increased anterior and posterior central corneal elevations in comparison to the best fit sphere. Ultrasound pachymetry showed central corneal thickness of 605μm (RE) and 612μm (LE). On specular biomicroscopy, cell density of 2503 cells/mm 2 RE and 1526 cells/mm 2 LE with significant cellular pleomorphism and polymegathism were noted. Clinical and paraclinical findings together suggest the presence of simultaneous keratoconus and PPCD. The literature has suggested an association between PPCD and steep cornea. Moreover, many reports have also described cases of associated PPCD and keratoconus with characteristic thinning and ectasia, in comparison to the unusual thick corneas noted in our patient, despite the absence of edema. Identification of genetics factors is further needed to clarify this association. This case describes a patient whose corneas present features of both keratoconus and PPCD and is unique due to the presence of increased corneal thickness despite the absence of edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Astigmatism evaluation prior to cataract surgery.

    PubMed

    Gupta, Pankaj C; Caty, Jane T

    2018-01-01

    To evaluate and summarize literature from the past 18 months reporting advancements and issues in astigmatism assessment prior to cataract surgery. New and updated toric calculators and regression formulas offer the opportunity for more accurate lens selection for our patients. Concurrently, improvements in topographic evaluation of corneal keratometry have allowed for a decrease in unplanned residual corneal astigmatism. Measuring posterior corneal astigmatism is especially valuable in eyes with keratoconus when planning to implant toric intraocular lens (IOL) and now allows access to this patient population. Improved accuracy of astigmatism evaluation now occurs with point reflections on the corneal surface along with the latest generation toric lens formulas which integrated posterior corneal astigmatism, predicted lens position, and intended spherical power of the IOL. These improvements can allow for incorporation of toric lenses in keratoconus patients.

  18. Evaluation of corneal biomechanics in patients with keratectasia following LASIK using dynamic Scheimpflug analyzer.

    PubMed

    Ueki, Ryotaro; Maeda, Naoyuki; Fuchihata, Mutsumi; Asai, Tomoko; Koh, Shizuka; Fujimoto, Hisataka; Uematsu, Masafumi; Nishida, Kohji

    2018-04-26

    To investigate the corneal biomechanics in eyes with keratectasia following LASIK using a dynamic Scheimpflug analyzer. Case-Control study. The subjects in the study included 12 eyes with keratectasia after LASIK (KE), 24 eyes with keratoconus (KC), 17 eyes without keratectasia after LASIK (LASIK), and 34 eyes with normal corneas (Normal). Corneal biomechanics of the four groups were evaluated using a dynamic Scheimpflug analyzer. Compared with Normal (7.06 ± 0.54), the radius at the highest concavity (radius, mm) of LASIK (5.96 ± 0.76), KE (4.93 ± 0.61) and KC (5.39 ± 1.02) were significantly small. The Deflection Amplitude (HCDLA, mm) of Normal (0.94 ± 0.07) was significantly lower than those of KE (1.11 ± 0.10) and KC (1.06 ± 0.16), and was not significantly different from that of LASIK (0.98 ± 0.07). There were significant differences between LASIK and KE in radius and HCDLA (P < 0.05), whereas KE and KC had no differences in these parameters. Corneal biomechanical features evaluated using the dynamic Scheimpflug analyzer suggest that biomechanical properties in eyes with keratectasia, keratoconus, and LASIK are different from those of normal eyes. Although the biomechanics in eyes with keratectasia differs from that in eyes with LASIK, it is similar to that in eyes with keratoconus.

  19. New screening methods for donor eye-bank eyes.

    PubMed

    Terry, M A; Ousley, P J

    1999-07-01

    Current methods of screening donor eyes for corneal transplantation are not always effective in excluding corneas with abnormal topography. We used the Orbscan to determine whether corneal-thickness maps could be used as a technique for donor tissue screening. Forty eye-bank eyes were measured with the Orbscan, and a corneal-thickness map was generated. Average central pachymetry measurements from each map were compared with the thinnest midperipheral thickness reading. Two eyes from a donor who had photorefractive keratectomy (PRK) and two eyes from a donor with keratoconus were then compared with the normal donor eye results. The average difference between the thinnest midperipheral pachymetry and the central pachymetry in the control group was 0.040 +/- 0.026 mm. The eyes from the donor with PRK showed larger disparities between the central and midperipheral thicknesses because of the thinned central cornea, with differences of 0.154 mm in the right eye and 0.106 mm in the left eye. The eyes from the donor with keratoconus had midperipheral corneas that were thinner than the center, indicating eccentric, ectatic cones. The differences in thickness between the center and midperiphery in the eyes from the donor with PRK and the donor with keratoconus differed from the control group by >2 SD. Diseases or surgery that affect the relationship between the central and midperipheral corneal thickness may be screened through Orbscan pachymetry mapping with comparison with a normal range.

  20. Indications and outcomes of pediatric keratoplasty in a tertiary eye care center: A retrospective review.

    PubMed

    Gulias-Cañizo, Rosario; Gonzalez-Salinas, Roberto; Hernandez-Zimbron, Luis Fernando; Hernandez-Quintela, Everardo; Sanchez-Huerta, Valeria

    2017-11-01

    To evaluate indications and outcomes of pediatric keratoplasty in a tertiary eye center, and identify factors that affect visual outcomes.We performed a retrospective review of penetrating keratoplasty in children aged 0 to 18 years between 1995 and 2011 in the Asociación para Evitar la Ceguera en México IAP, Hospital "Dr. Luis Sánchez Bulnes".A total of 574 penetrating keratoplasties were performed during the study interval. Median follow-up was 5.0 years. Main indications included keratoconus (55.58%), postherpetic scarring (9.58%), traumatic opacities (7.49%), and bullous keratopathy (6.09%). Rejection rates at 5 years were 27% overall, and among indications, keratoconus showed the best graft survival at 60-months follow-up (85%). The percentage of patients with best corrected visual acuity (BCVA) posttransplant >20/400 at 5 years in the nonrejection group was 81.25% and 82.74% in < and > 10 years of age (YOA) groups, respectively, versus a BCVA posttransplant > 20/400 at 5 years in the rejection group of 53.68% and 51.72% in < and > 10 YOA groups, respectively. There was a statistically significant reduced rejection rate between genders at 18 months of follow-up, favoring males.Despite being considered a high-risk procedure in children, penetrating keratoplasty can achieve good results, especially in patients with keratoconus. It can achieve significative improvements of visual acuity, provided there is an adequate follow-up and treatment adherence.

  1. Corneal Transplantation in Auckland, New Zealand, 1999-2009: Indications, Patient Characteristics, Ethnicity, Social Deprivation, and Access to Services.

    PubMed

    Crawford, Alexandra Z; McKelvie, James; Craig, Jennifer P; McGhee, Charles N J; Patel, Dipika V

    2017-05-01

    To analyze characteristics and indications for corneal transplantation in patients undergoing penetrating, lamellar, and endothelial keratoplasty in Auckland, New Zealand (NZ). Corneal transplantation data from the NZ National Eye Bank and hospital records of corneal transplant recipients in the Auckland region from January 1, 2000, to December 31, 2009, were collated. Patient demographics, preoperative diagnosis, indication, ocular and medical history, visual acuity, deprivation index, and access to transplantation surgery were analyzed. A total of 941 corneal transplants involving 770 patients were included for analysis. Mean age was 46 years. Age and ethnicity varied according to the transplant indication. A male preponderance and disproportionally high rates of Māori and Pacific ethnicity with a mean age of 30 years were observed in transplants for keratoconus. A total of 67.2% of corneal transplants were completed in the public health system and were associated with higher levels of deprivation than those completed in private facilities. Preoperative visual acuity varied according to the transplant type and indication. The most common clinical indication for corneal transplantation was keratoconus (41.3%), followed by repeat transplantation (21.0%). There was no significant change in the relative proportion of transplant indications in any year over the duration of this study (P = 0.41). A contralateral corneal transplant was present in 24.4% and glaucoma in 12.8% of penetrating keratoplasty recipients. Keratoconus is the leading indication for corneal transplantation in Auckland, NZ, and involves a disproportionately high rate of Māori and Pacific transplant recipients with a male preponderance and comparatively low mean age at the time of surgery.

  2. The relationship between corneal biomechanical properties and confocal microscopy findings in normal and keratoconic eyes.

    PubMed

    Hurmeric, Volkan; Sahin, Afsun; Ozge, Gokhan; Bayer, Atilla

    2010-06-01

    To investigate the relationship between corneal biomechanical properties and confocal microscopy (CM) findings in normal and keratoconic eyes. The study consisted of 28 eyes of 28 healthy volunteers and 23 eyes of 15 patients with keratoconus. The diagnosis of keratoconus was made with corneal topography and clinical findings. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured by the ocular response analyzer. In vivo CM was performed with NIDEK Confoscan 3. CH and CRF were compared with corneal morphological findings (detailed cell counts of endothelial, stromal, and epithelial cells) in vivo. CH was 10.1 +/- 1.3 mm Hg in normal eyes and 7.4 +/- 1.5 mm Hg in keratoconic eyes (P < 0.0001). CRF was 10.1 +/- 1.8 mm Hg in normal eyes and 6.2 +/- 1.4 mm Hg in keratoconic eyes (P < 0.0001). CH and CRF were negatively correlated with full-thickness stromal keratocyte density (P < 0.01; r = -0.52 and P < 0.001; r = -0.67, respectively) in healthy eyes. Keratocyte density of the posterior half of the stroma was found to be significantly related with CRF in healthy eyes (beta = -0.404; P = 0.01). There was no significant relationship among CH, CRF, and CM findings in eyes with keratoconus. There is a significant relationship between CRF and keratocyte density of the posterior half of the stroma in healthy eyes. Our results suggest that corneal elasticity is related to not only stromal matrix but also cellular structure of the cornea.

  3. Combined application of prophylactic corneal cross-linking and laser in-situ keratomileusis - a review of literature.

    PubMed

    Chan, Tommy C Y; Ng, Alex L K; Chan, Karen K W; Cheng, George P M; Wong, Ian Y H; Jhanji, Vishal

    2017-11-01

    Laser in-situ keratomileusis (LASIK) is safe and effective laser refractive procedures in treating refractive errors. However, regression of treatment and iatrogenic keratectasia remain to be a major concern, especially in treating thin cornea with high ametropia. Collagen cross-linking (CXL) is an effective method in stopping keratoconus progression through increasing the biomechanical strength of the cornea. Adjuvant cross-linking to refractive procedures can theoretically help prevent regression and reduce the risk of keratectasia development by increasing the mechanical stability of cornea. During the procedure, riboflavin is directly applied to the corneal stroma, thereby reducing the need of de-epithelialization as in the conventional protocol for keratoconus. Currently, there is still no consensus regarding the indication of CXL during refractive procedure, nor any standardized treatment protocol. This article aims to summarize the current evidence regarding the use of adjuvant CXL in LASIK. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Clinical and epidemiological aspects of cornea transplant patients of a reference hospital 1

    PubMed Central

    Cruz, Giovanna Karinny Pereira; de Azevedo, Isabelle Campos; Carvalho, Diana Paula de Souza Rego Pinto; Vitor, Allyne Fortes; Santos, Viviane Euzébia Pereira; Ferreira, Marcos Antonio

    2017-01-01

    ABSTRACT Objective: clinically characterizing cornea transplant patients and their distribution according to indicated and post-operative conditions of cornea transplantation, as well as estimating the average waiting time. Method: a cross-sectional, descriptive and analytical study performed for all cornea transplants performed at a reference service (n=258). Data were analyzed using Statistical Package for the Social Sciences, version 20.0. Results: the main indicator for cornea transplant was keratoconus. The mean waiting time for the transplant was approximately 5 months and 3 weeks for elective transplants and 9 days for urgent cases. An association between the type of corneal disorder with gender, age, previous surgery, eye classification, glaucoma and anterior graft failure were found. Conclusion: keratoconus was the main indicator for cornea transplant. Factors such as age, previous corneal graft failure (retransplantation), glaucoma, cases of surgeries prior to cornea transplant (especially cataract surgery) may be related to the onset corneal endothelium disorders. PMID:28614429

  5. Elastic microfibril distribution in the cornea: Differences between normal and keratoconic stroma.

    PubMed

    White, Tomas L; Lewis, Philip N; Young, Robert D; Kitazawa, Koji; Inatomi, Tsutomu; Kinoshita, Shigeru; Meek, Keith M

    2017-06-01

    The optical and biomechanical properties of the cornea are largely governed by the collagen-rich stroma, a layer that represents approximately 90% of the total thickness. Within the stroma, the specific arrangement of superimposed lamellae provides the tissue with tensile strength, whilst the spatial arrangement of individual collagen fibrils within the lamellae confers transparency. In keratoconus, this precise stromal arrangement is lost, resulting in ectasia and visual impairment. In the normal cornea, we previously characterised the three-dimensional arrangement of an elastic fiber network spanning the posterior stroma from limbus-to-limbus. In the peripheral cornea/limbus there are elastin-containing sheets or broad fibers, most of which become microfibril bundles (MBs) with little or no elastin component when reaching the central cornea. The purpose of the current study was to compare this network with the elastic fiber distribution in post-surgical keratoconic corneal buttons, using serial block face scanning electron microscopy and transmission electron microscopy. We have demonstrated that the MB distribution is very different in keratoconus. MBs are absent from a region of stroma anterior to Descemet's membrane, an area that is densely populated in normal cornea, whilst being concentrated below the epithelium, an area in which they are absent in normal cornea. We contend that these latter microfibrils are produced as a biomechanical response to provide additional strength to the anterior stroma in order to prevent tissue rupture at the apex of the cone. A lack of MBs anterior to Descemet's membrane in keratoconus would alter the biomechanical properties of the tissue, potentially contributing to the pathogenesis of the disease. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Identification of a G‐Protein Subunit‐α11 Gain‐of‐Function Mutation, Val340Met, in a Family With Autosomal Dominant Hypocalcemia Type 2 (ADH2)

    PubMed Central

    Piret, Sian E; Gorvin, Caroline M; Pagnamenta, Alistair T; Howles, Sarah A; Cranston, Treena; Rust, Nigel; Nesbit, M Andrew; Glaser, Ben; Taylor, Jenny C; Buchs, Andreas E; Hannan, Fadil M

    2016-01-01

    ABSTRACT Autosomal dominant hypocalcemia (ADH) is characterized by hypocalcemia, inappropriately low serum parathyroid hormone concentrations and hypercalciuria. ADH is genetically heterogeneous with ADH type 1 (ADH1), the predominant form, being caused by germline gain‐of‐function mutations of the G‐protein coupled calcium‐sensing receptor (CaSR), and ADH2 caused by germline gain‐of‐function mutations of G‐protein subunit α‐11 (Gα11). To date Gα11 mutations causing ADH2 have been reported in only five probands. We investigated a multigenerational nonconsanguineous family, from Iran, with ADH and keratoconus which are not known to be associated, for causative mutations by whole‐exome sequencing in two individuals with hypoparathyroidism, of whom one also had keratoconus, followed by cosegregation analysis of variants. This identified a novel heterozygous germline Val340Met Gα11 mutation in both individuals, and this was also present in the other two relatives with hypocalcemia that were tested. Three‐dimensional modeling revealed the Val340Met mutation to likely alter the conformation of the C‐terminal α5 helix, which may affect G‐protein coupled receptor binding and G‐protein activation. In vitro functional expression of wild‐type (Val340) and mutant (Met340) Gα11 proteins in HEK293 cells stably expressing the CaSR, demonstrated that the intracellular calcium responses following stimulation with extracellular calcium, of the mutant Met340 Gα11 led to a leftward shift of the concentration‐response curve with a significantly (p < 0.0001) reduced mean half‐maximal concentration (EC50) value of 2.44 mM (95% CI, 2.31 to 2.77 mM) when compared to the wild‐type EC50 of 3.14 mM (95% CI, 3.03 to 3.26 mM), consistent with a gain‐of‐function mutation. A novel His403Gln variant in transforming growth factor, beta‐induced (TGFBI), that may be causing keratoconus was also identified, indicating likely digenic

  7. Automated Decision Tree Classification of Corneal Shape

    PubMed Central

    Twa, Michael D.; Parthasarathy, Srinivasan; Roberts, Cynthia; Mahmoud, Ashraf M.; Raasch, Thomas W.; Bullimore, Mark A.

    2011-01-01

    Purpose The volume and complexity of data produced during videokeratography examinations present a challenge of interpretation. As a consequence, results are often analyzed qualitatively by subjective pattern recognition or reduced to comparisons of summary indices. We describe the application of decision tree induction, an automated machine learning classification method, to discriminate between normal and keratoconic corneal shapes in an objective and quantitative way. We then compared this method with other known classification methods. Methods The corneal surface was modeled with a seventh-order Zernike polynomial for 132 normal eyes of 92 subjects and 112 eyes of 71 subjects diagnosed with keratoconus. A decision tree classifier was induced using the C4.5 algorithm, and its classification performance was compared with the modified Rabinowitz–McDonnell index, Schwiegerling’s Z3 index (Z3), Keratoconus Prediction Index (KPI), KISA%, and Cone Location and Magnitude Index using recommended classification thresholds for each method. We also evaluated the area under the receiver operator characteristic (ROC) curve for each classification method. Results Our decision tree classifier performed equal to or better than the other classifiers tested: accuracy was 92% and the area under the ROC curve was 0.97. Our decision tree classifier reduced the information needed to distinguish between normal and keratoconus eyes using four of 36 Zernike polynomial coefficients. The four surface features selected as classification attributes by the decision tree method were inferior elevation, greater sagittal depth, oblique toricity, and trefoil. Conclusions Automated decision tree classification of corneal shape through Zernike polynomials is an accurate quantitative method of classification that is interpretable and can be generated from any instrument platform capable of raw elevation data output. This method of pattern classification is extendable to other classification

  8. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    NASA Astrophysics Data System (ADS)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  9. Evaluation of Topical Cyclosporine in Preventing the Development of Corneal Haze after Photorefractive Keratectomy

    DTIC Science & Technology

    2014-05-13

    use of systemic corticosteroids, abnormal ophthalmic examination, and topographic evidence of keratoconus or warpage from contact 4 lenses...Systemic medications were permitted unless they were known to affect the cornea. Soft contact lenses were removed at least thirty days and hard contact ... contact lens was placed at conclusion of the treatment. All eyes received standard postoperative management during the first week including topical

  10. Histopathologic analysis of successful endothelial keratoplasty following multiple failed keratoplasties.

    PubMed

    Epstein, Rachel H; Mamalis, Nick; Price, Francis W; Price, Marianne O

    2015-02-01

    A 68-year-old woman with bilateral keratoconus presented with persistent visual acuity deficits following cataract extraction with a neodymium:YAG capsulotomy in the right eye 2 years earlier. Penetrating keratoplasty (PKP) had been performed for keratoconus in the right eye without complications until steroid drops were discontinued after 10 years because of persistent elevated intraocular pressure. The right eye experienced immunologic rejection and failure of 3 PKPs, 1 Descemet-stripping endothelial keratoplasty (DSEK), and a trabeculectomy with an eventual anatomically successful DSEK before the patient died at 95 years of age. The left eye improved following a single PKP. Postmortem histopathologic analysis of the cornea showed an anatomically successful DSEK graft with intact donor Descemet membrane and viable graft endothelial cells. To our knowledge, this is the first histopathologic analysis of an anatomically successful DSEK after multiple failed PKPs and trabeculectomy. The course in this case supports early consideration of lamellar keratoplasty, especially in patients with ocular comorbidities. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Persistent Epithelial Defects and Corneal Opacity After Collagen Cross-Linking With Substitution of Dextran (T-500) With Dextran Sulfate in Compounded Topical Riboflavin.

    PubMed

    Höllhumer, Roland; Watson, Stephanie; Beckingsale, Peter

    2017-03-01

    Collagen cross-linking (CXL) is a commonly performed procedure to prevent the progression of keratoconus. Riboflavin is an essential part of the procedure, which facilitates both the cross-linking process and protection of intraocular structures. Dextran can be added to riboflavin to create an isotonic solution. This case report highlights the importance of compounding riboflavin with the correct dextran solution. A retrospective case series. Six eyes of 4 male patients with keratoconus aged from 20 to 38 years underwent CXL with substitution of 20% dextran (T-500) with 20% dextran sulfate in a compounded riboflavin 0.1% solution. Postoperatively, persistent corneal epithelial defects, stromal haze, and then scarring occurred. Corneal transplantation was performed for visual rehabilitation but was complicated by graft rejection followed by failure (n = 1 eye), dehiscence (n = 4), cataract (n = 2), post-laser ablation haze (n = 1), and steroid-induced glaucoma (n = 2). The visual outcome was <6/18 in all 6 cases because of irregular astigmatism and stromal haze. Thinning, vascularization, and scarring of the residual host tissue were noted. Substitution of dextran (T-500) with dextran sulfate in riboflavin solutions during CXL results in loss of vision from permanent corneal opacity. Residual host changes may compromise the results of corneal transplantation.

  12. Visual performance with changes in eccentricity in PROSE device: a case report.

    PubMed

    Jagadeesh, Divya; Mahadevan, Rajeswari

    2014-01-01

    This case report describes the variations in visual performance of a subject with moderate keratoconus with changes in front surface eccentricities (FSEs) of PROSE (Prosthetic Replacement of Ocular Surface Ecosystem). PROSE device of 0.6 FSE provided maximum visual improvement and reduction in Higher Order Aberrations (HOAs) compared to 0, 0.3 and 0.8 FSEs in this clinical condition. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  13. Severe acute corneal hydrops in a patient with Down syndrome and persistent eye rubbing.

    PubMed

    Ozcan, Altan A; Ersoz, T Reha

    2007-01-01

    We report a case of severe acute corneal hydrops in an 11-year-old boy with keratoconus associated with Down syndrome and vigorous eye rubbing. Complete resolution of the corneal edema and a central corneal scar was seen in the 8th week of final follow-up. Eye-rubbing may play a role in the pathogenesis of acute hydrops, and conventional therapy can be successful in its management, even in severe cases.

  14. [Biomechanical condition of the cornea as a new indicator for pathological and structural changes].

    PubMed

    Spörl, E; Terai, N; Haustein, M; Böhm, A G; Raiskup-Wolf, F; Pillunat, L E

    2009-06-01

    Several methods permit the measurement of geometric parameters of the cornea, but until now biomechanical conditions of the cornea have been ignored (e.g. in refractive corneal surgery). Besides the geometric condition, biomechanical properties of the cornea have been shown to influence applanation measurement of intra-ocular pressure (IOP) and epidemiological studies have identified corneal thickness as an independent risk factor for the development and progression of glaucoma. The aim of this investigation was to characterize the biomechanical properties of the cornea using the ocular response analyzer (ORA). The ocular response analyzer (ORA) is a new method available for non-contact measurement of the biomechanical properties of the cornea. We evaluated the reproducibility of measurements, the difference between static and dynamic factors and the impact of independent factors (e.g. IOP, age, CCT, swelling of the cornea) on 2,500 measurements of corneal hysteresis (CH) and corneal resistance factor (CRF). In a large sample size we observed changes in CH and CRF after refractive surgery procedures (LASIK, UV-A cross-linking, keratoplasty) and in other corneal disorders (keratoconus, corneal dystrophies). CRF and CH changes may reflect structural changes of the cornea. Thus, the ORA provides valuable information for a better understanding and characterization of the biomechanical condition of the cornea, especially with regard to diseases such as keratoconus and glaucoma.

  15. Intraoperative Optical Coherence Tomography Using the RESCAN 700: Preliminary Results in Collagen Crosslinking.

    PubMed

    Pahuja, Natasha; Shetty, Rohit; Jayadev, Chaitra; Nuijts, Rudy; Hedge, Bharath; Arora, Vishal

    2015-01-01

    To compare the penetration of riboflavin using a microscope-integrated real time spectral domain optical coherence tomography (ZEISS OPMI LUMERA 700 and ZEISS RESCAN 700) in keratoconus patients undergoing accelerated collagen crosslinking (ACXL) between epithelium on (epi-on) and epithelium off (epi-off). Intraoperative images were obtained during each of the procedures. Seven keratoconus patients underwent epi-on ACXL and four underwent epi-off ACXL. A software tool was developed using Microsoft.NET and Open Computer Vision (OpenCV) libraries for image analysis. Pre- and postprocedure images were analyzed for changes in the corneal hyperreflectance pattern as a measure of the depth of riboflavin penetration. The mean corneal hyperreflectance in the epi-on group was 12.97 ± 1.49 gray scale units (GSU) before instillation of riboflavin and 14.46 ± 2.09 GSU after AXCL (P = 0.019) while in the epi-off group it was 11.43 ± 2.68 GSU and 16.98 ± 8.49 GSU, respectively (P = 0.002). The average depth of the band of hyperreflectance in the epi-on group was 149.39 ± 15.63 microns and in the epi-off group it was 191.04 ± 32.18 microns. This novel in vivo, real time imaging study demonstrates riboflavin penetration during epi-on and epi-off ACXL.

  16. Behaviour modification in the management of chronic habits of abnormal eye rubbing.

    PubMed

    McMonnies, Charles W

    2009-04-01

    To describe how and why many keratoconus patients do not comply with strong advice to control chronic habits of abnormal rubbing. To outline a behaviour modification approach for controlling chronic habits of abnormal rubbing. Common reasons for chronic habits of abnormal rubbing have been reviewed as a basis for specifying a behavioural modification approach to habit reversal. The methods described are organized into the classic behavioural modification structure of: (1) habit awareness, (2) competing responses, (3) development of motivation, and (4) social support. This structure is supported by the application of social influence principles to achieve optimum compliance. The use of take-home written information in the form of an Abnormal Rubbing Guide is the basis for the development of motivation. Family social support is based upon a widening of the responsibility for avoiding eye rubbing to all family members. Some patients will need minimal application of these principles with patient education being sufficient intervention to achieve habit reversal. For patients with strong provocation to rubbing and/or by having a well established rubbing habit, a greater exposure to the habit reversal program described is indicated. Successful habit reversal may slow the rate of ectasia progression. Prophylactic application of the methods described for patients who are at risk for developing keratoconus, or post-laser assisted in situ keratomileusis keratectasia, may show that some forms of keratectasia are preventable.

  17. Delivery of Riboflavin-5'-Monophosphate Into the Cornea: Can Liposomes Provide Any Enhancement Effects?

    PubMed

    Kandzija, Neva; Khutoryanskiy, Vitaliy V

    2017-10-01

    Keratoconus is a progressive condition caused by the thinning of the cornea, which eventually deforms the front surface of the eye into a cone shape leading to ghosting, multiple images, glare, and several other vision problems. Currently, keratoconus is treated with UV-induced riboflavin (Rb)-mediated collagen cross-linking, which requires a physical removal of the corneal epithelium under topical anesthesia. This study reports the penetration of Rb and its more water-soluble form, riboflavin-5'-monophosphate (RbP), into the bovine cornea ex vivo. Using ex vivo bovine corneal tissues and 0.8 mg/mL drug solutions in phosphate buffer, it was established that RbP penetration into the cornea within 3 h of diffusion experiment was greater (17.3 ± 0.8 μg) compared with Rb (10.4 ± 4.2 μg). In the cornea, RbP was found to convert to Rb, which is mediated with enzymes present in this tissue. Several formulations including the conventional and propylene glycol-containing liposomes with encapsulated RbP have been developed, and their effect on the drug penetration into the bovine cornea was evaluated. Encapsulation of RbP into the liposomes did not provide any statistically significant improvement in the penetration of RbP into the cornea. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  18. Normal and keratoconic corneal epithelial thickness mapping using Fourier-domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Li, Yan; Tan, Ou; Huang, David

    2011-03-01

    The detection of early-stage keratoconus is one of the most important safety issues in screening candidates for corneal refractive surgeries. We propose to use epithelial thickness maps to assist the diagnosis of keratoconus. The corneal epithelial thickness in normal and keratoconic eyes was mapped with optical coherence tomography (OCT). A Fourier-domain OCT system capable of acquiring 26,000 axial-scans per second was used. It has an axial resolution of 5μm in cornea. A pachymetry scan pattern (8 radials, 1024 axial-scans each, 6mm diameter, repeat 3 times) centered at the pupil center was used to image the cornea. The 3 repeated radial scans on each meridian were registered and averaged. Then the anterior corneal, posterior corneal and epithelial boundaries were segmented automatically with a computer algorithm by increased signal intensity at corresponding boundaries. The epithelial thickness map was generated by interpolating epithelial thickness profile calculated from each meridian. Normal and keratoconic eyes (24 eyes each) were scanned 3 times. The central epithelial thickness in normal eyes was thicker than those of keratoconic eyes (mean difference 2.1 μm, t-test p=0.05). The epithelium was thinner superiorly than inferiorly in normal eyes (mean difference -1.4+/-1.1μm, p<0.001) while thicker superiorly than inferiorly in keratoconic eyes (2.0+/-4.1 μm, p=0.02).

  19. Corneal Complications And Visual Impairment In Vernal Keratoconjunctivitis Patients.

    PubMed

    Arif, Abdus Salam; Aaqil, Bushra; Siddiqui, Afsheen; Nazneen, Zainab; Farooq, Umer

    2017-01-01

    Vernal kerato-conjunctivitis (VKC) is an infrequent but serious form of allergic conjunctivitis common in warm and humid areas where air is rich in allergens. It affects both eyes asymmetrically. Although VKC is a self-limiting disease but visions affecting corneal complications influence the quality of life in school children. The aim of this study was to list the corneal complications due to this condition and to find out the extent of visual impairment among VKC patients. This cross-sectional study was conducted in the department of Ophthalmology, Benazir Bhutto Shaheed Hospital on 290 eyes of diagnosed cases of VKC. The diagnosis of VKC was made on the basis of history and examination. Visual acuity was recorded using Snellen's notation and visual impairment was classified according to World Health Organization classification for visual disabilities. The mean age of presentation was 10.83±6.13 years. There were 207 (71.4%) males and 83 (28.6%) females. Corneal scarring was observed in 59 (20.3%) eyes. Keratoconus was found to be in 17 (5.9%) eyes. Shield ulcer was detected in 09 (3.1%) eyes while 07 (2.4%) eyes had corneal neovascularization. Majority of the patients with visual loss had corneal scarring and the complication that led to severe visual loss in most of the eyes was Keratoconus. Vernal kerato-conjunctivitis in the presence of corneal complications is a sight threatening disease and can lead to severe visual impairment.

  20. Acanthamoeba keratitis in patients wearing scleral contact lenses.

    PubMed

    Sticca, Matheus Porto; Carrijo-Carvalho, Linda C; Silva, Isa M B; Vieira, Luiz A; Souza, Luciene B; Junior, Rubens Belfort; Carvalho, Fábio Ramos S; Freitas, Denise

    2018-06-01

    To report a series of cases of Acanthamoeba keratitis (AK) in scleral lens wearers with keratoconus to determine whether this type of contact lens presents a greater risk for development of infection. This study reports three patients who wore scleral contact lenses to correct keratoconus and developed AK. The diagnoses of AK were established based on cultures of the cornea, scleral contact lenses, and contact lens paraphernalia. This study investigated the risk factors for infections. The possible risks for AK in scleral contact lens wearers are hypoxic changes in the corneal epithelium because of the large diameter and minimal tear exchange, use of large amounts of saline solution necessary for scleral lens fitting, storing the scleral lens overnight in saline solution rather than contact lens multipurpose solutions, not rubbing the contact lens during cleaning, and the space between the cornea and the back surface of the scleral lens that might serve as a fluid reservoir and environment for Acanthamoeba multiplication. Two patients responded well to medical treatment of AK; one is still being treated. The recommendations for use and care of scleral contact lenses should be emphasized, especially regarding use of sterile saline (preferably single use), attention to rubbing the lens during cleaning, cleaning of the plunger, and overnight storage in fresh contact lens multipurpose solutions without topping off the lens solution in the case. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. Identification of biomechanical properties of the cornea: the ocular response analyzer.

    PubMed

    Terai, Naim; Raiskup, Frederik; Haustein, Michael; Pillunat, Lutz E; Spoerl, Eberhard

    2012-07-01

    Several methods have been devised for measuring geometric parameters of the cornea but, until now, the biomechanics of the cornea have been largely ignored. The relatively new Ocular Response Analyzer (ORA) provides such biomechanical information. In order to correctly interpret the underlying biomechanics of ORA data, we review reported ORA measurements and provide a compendium of factors influencing these measurements, with discussion of possible explanations for ORA measurement results. This review comprised a literature search using "ocular response analyzer" and "ocular response analyser" as keywords. We reviewed and compared reported results from recent ORA studies so obtained, with an eye to understanding corneal biomechanics. Several ORA biomechanical parameters of the cornea - corneal hysteresis (CH) and corneal resistant factor (CRF) - characterize the viscoelastic properties of the cornea, especially those of the ground substance. The impact on CH and CRF values of various independent factors, e.g. intraocular pressure (IOP), age, central corneal thickness (CCT), and corneal swelling, are discussed. The impact on CH and CRF of treatment-related structural changes of the cornea, i.e. those occurring after refractive surgical procedures, placement of intracorneal rings, and collagen crosslinking (CXL), as well as pathological changes of the cornea, e.g. those resulting from keratoconus, edema, and glaucoma, are discussed. Changes in CRF and CH may be reflective of structural changes in the ground substance of the cornea. Thus, ORA provides invaluable information for delineating biomechanical conditions pertaining to the cornea, with special regard to ocular diseases, e.g. keratoconus and glaucoma.

  2. Is it really important to form a big bubble in DALK to enhance the visual acuity?

    PubMed

    Acar, Banu Torun; Vural, Ece Turan; Acar, Suphi

    2012-09-01

    The aim of this study was to investigate the prognosis of visual acuity (VA) in the patients with keratoconus, who underwent deep anterior lamellar keratoplasty (DALK) with a successful big bubble or lamellar dissection. Sixty-eight eyes of 60 patients with keratoconus, who underwent DALK using the big-bubble technique, were enrolled in this retrospective comparative study. The VA and refractive errors were assessed before the operation and, thereafter, at months 1, 3, 6, and 12 after the operation (1) in the patients who achieved a big-bubble formation, and in those who required layer-by-layer lamellar dissection (2) to reach the Descemet membrane. Successful big bubble was achieved in 50 eyes (73.5 %) (group 1), and lamellar dissection was performed in 18 eyes (26.5 %) (group 2). The mean follow-up period was 22.4±6.2 months in group 1 and 23.7±7.8 months in group 2 (P=0.562). Although best-corrected visual acuity (BCVA) values observed at months 1 and 3 were significantly higher in group 1 than in group 2 (P=0.016 and P=0.024, respectively), there was no statistically significant difference between the two groups for BCVA values observed at months 6 and 12 (P=0.412 and P=0.528, respectively). Although the visual recovery was delayed in the early postoperative follow-up because of residual stroma in lamellar dissection, the final results were comparable between the achievement of big-bubble formation and lamellar dissection.

  3. Improved High-Frequency Ultrasound Corneal Biometric Accuracy by Micrometer-Resolution Acoustic-Property Maps of the Cornea.

    PubMed

    Rohrbach, Daniel; Silverman, Ronald H; Chun, Dan; Lloyd, Harriet O; Urs, Raksha; Mamou, Jonathan

    2018-04-01

    Mapping of epithelial thickness (ET) is useful for detection of keratoconus, a disease characterized by corneal thinning and bulging in which epithelial thinning occurs over the apex. In prior clinical studies, optical coherence tomography (OCT) measurements of ET were systematically thinner than those obtained by 40-MHz high-frequency ultrasound (HFU) where a constant speed of sound ( c ) of 1636 m/s was used for all corneal layers. The purpose of this work was to study the acoustic properties, that is, c , acoustic impedance ( Z ), and attenuation ( α ) of the corneal epithelium and stroma independently using a scanning acoustic microscope (SAM) to investigate the discrepancy between OCT and HFU estimates of ET. Twelve unfixed pig corneas were snap-frozen and 6-μm sections were scanned using a custom-built SAM with an F-1.08, 500-MHz transducer and a 264-MHz bandwidth. Two-dimensional maps of c , Z , and α with a spatial resolution of 4 μm were derived. SAM showed that the value of c in the epithelium (i.e., 1548 ± 18 m/s) is substantially lower than the value of c in the stroma (i.e., 1686 ± 33 m/s). SAM results demonstrated that the assumption of a constant value of c for all corneal layers is incorrect and explains the prior discrepancy between OCT and HFU ET determinations. The findings of this study have important implications for HFU-based ET measurements and will improve future keratoconus diagnosis by providing more-accurate ET estimates.

  4. The influence of Australian eye banking practices on corneal graft survival.

    PubMed

    Keane, Miriam C; Lowe, Marie T; Coster, Douglas J; Pollock, Graeme A; Williams, Keryn A

    2013-08-19

    To identify eye banking practices that influence corneal graft survival. Prospective cohort study of records of 19,254 followed corneal grafts in 15160 patients, submitted to the Australian Corneal Graft Registry between May 1985 and July 2012. Influence of corneal preservation method (organ culture, moist pot, Optisol, other); death-to-enucleation, death-to-preservation and enucleation-to-graft times; transportation by air; graft era; and indication for graft on probability of graft survival at most recent follow-up. In multivariate analysis, 919 penetrating grafts performed using corneas transported interstate by air exhibited worse survival than 14,684 grafts performed using corneas retrieved and used locally (hazard ratio [HR], 1.44; 95% CI, 1.21-1.73; P = 0.001). This was also the case for traditional lamellar grafts (64 corneas transported by air and 813 used locally; HR, 1.69; 95% CI, 1.03-2.78; P = 0.038). Indication for graft influenced survival of penetrating grafts (4611 keratoconus, 727 emergency or high-risk, 10,265 other indication; global P < 0.001) and traditional lamellar grafts (65 keratoconus, 212 emergency or high-risk, 600 other indication; global P < 0.001). The preservation medium in which corneas used for traditional lamellar grafts were stored exerted a marginal influence on graft survival (global P = 0.047). Donor corneas transported interstate exhibited poorer survival after transplantation than those retrieved and grafted locally. Higher proportions of emergency procedures involving transported corneas did not account for this difference. Where possible, efforts to avoid transportation of corneal tissue by air freight within Australia may be warranted.

  5. Analysis of pupil and corneal wave aberration data supplied by the SN CT 1000 topography system

    NASA Astrophysics Data System (ADS)

    Comastri, S. A.; Martin, G.; Pfortner, T.

    2006-11-01

    Ocular aberrations depend on pupil size and centring and the retinal image quality under natural conditions differs from that corresponding to laboratory ones. In the present article, pupil and wave aberration data supplied by the Shin Nippon CT 1000 (SN CT 1000) topography system are analysed. Two groups of eyes under natural viewing conditions are considered ((260+/-20) lux at the eye under study). The first group consists of 10 normal eyes (-1.25 to 3 D sphere; 0 to -1.75 D cylinder) of five young subjects (age between 18 and 33 years). For this group, five determinations per eye are performed and the repeatability of results is analysed. Pupil centre is displaced from corneal vertex towards the temporal region, the largest displacement being (0.5+/-0.1) mm. The variation of pupil diameter in each eye is less than 21% while the inter-subject variability is large since diameters are between (3+/-0.3) and (5.3+/-0.6) mm. Aberrations are evaluated for two different pupil sizes, the natural one and a fictitious one of 6 mm. The corneal higher-order root-mean square wavefront error (RMSHO) for a 6 mm pupil centred in the corneal vertex, averaged across all eyes, is (0.37+/-0.06) [mu]m while, considering the natural pupil diameter, the average in each eye is significantly lower, up to eight times smaller. The fourth-order spherical aberration is an important aberration in the considered eyes, its maximum value for a 6 mm pupil being (0.38+/-0.02) [mu]m. The second group consists of 24 eyes of 12 subjects (age between 25 and 68 years) such that four eyes are of normal adults (1.25 to +6 D sphere; 0 to -0.5 D cylinder), eight have astigmatisms (-5.5 to +3.25 D sphere; -1.5 to -4.5 D cylinder), six have post-refractive surgery (+0.5 to +3.5 D sphere; -0.5 to -4 D cylinder) and six have keratoconus (-9.5 to +1 D sphere; -1 to -4.5 D cylinder). For this group only one determination per eye is performed. Pupil centre is displaced from corneal vertex towards the temporal

  6. New pinhole sulcus implant for the correction of irregular corneal astigmatism.

    PubMed

    Trindade, Claudio C; Trindade, Bruno C; Trindade, Fernando C; Werner, Liliana; Osher, Robert; Santhiago, Marcony R

    2017-10-01

    To evaluate the effect on visual acuity of the implantation of a new intraocular pinhole device (Xtrafocus) in cases of irregular corneal astigmatism with significant visual impairment. University of São Paulo, São Paulo, Brazil. Prospective case series. Pseudophakic eyes of patients with irregular corneal astigmatism were treated with the pinhole device. The causes of irregular corneal astigmatism were keratoconus, post radial keratotomy (RK), post-penetrating keratoplasty (PKP), and traumatic corneal laceration. The device was implanted in the ciliary sulcus in a piggyback configuration to minimize the effect of corneal aberrations. Preoperative and postoperative visual parameters were compared. The main outcome variables were manifest refraction, uncorrected and corrected distance and near visual acuities, subjective patient satisfaction, and intraoperative and postoperative adverse events and complications. Twenty-one patients (ages 35 to 85 years) were included. There was statistically significant improvement in uncorrected and corrected (CDVA) distance visual acuities. The median CDVA improved from 20/200 (range 20/800 to 20/60) preoperatively to 20/50 (range 20/200 to 20/20) in the first month postoperatively and remained stable over the following months. Manifest refraction remained unchanged, while a subjective visual performance questionnaire revealed perception of improvement in all the tested working distances. No major complication was observed. One case presented with decentration of the device, which required an additional surgical intervention. The intraocular pinhole device performed well in patients with irregular astigmatism caused by keratoconus, RK, PKP, and traumatic corneal laceration. There was marked improvement in visual function, with high patient satisfaction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Central Corneal Thickness Measurement Using Ultrasonic Pachymetry, Rotating Scheimpflug Camera, and Scanning-slit Topography Exclusively in Thin Non-keratoconic Corneas.

    PubMed

    Mohammadpour, Mehrdad; Mohammad, Kazem; Karimi, Nasser

    2016-01-01

    To evaluate the agreement among Pentacam, Orbscan and ultrasound (US) pachymetry for measurement of central corneal thickness (CCT) in thin corneas with normal topographic pattern. We included 88 eyes of 44 refractive surgery candidates with thinnest pachymetric readings of 500 micrometers (μm) or less on Orbscan, a normal topographic pattern, no sign of keratoconus, and best corrected visual acuity (BCVA) of 20/20. Pentacam, Orbscan and US were performed in one session by the same examiner. Exclusion criteria were history of ocular surgery, topographic abnormalities suggesting forme fruste keratoconus or keratectasia, and recent contact lens wear. The difference in CCT measurements by US pachymetry and Orbscan II [using an acoustic factor (AF) of 0.92] ranged from -34 to +34 μm. The difference between the thinnest point and central readings measured by US reached 16 μm with Orbscan II (AF: 0.92) and 2 μm with Pentacam. Mean differences between the employed devices were 0.2 μm for Pentacam versus US (P = 0.727), 30.1 μm for uncorrected Orbscan versus US (P < 0.001), 10.4 μm for Orbscan II (AF = 0.92) versus US (P < 0.001), and 0.2 μm for Orbscan II (AF = 0.94) versus US (P = 0.851). In normal thin corneas, Pentacam demonstrated better agreement with US pachymetry as compared to corrected Orbscan readings. Results achieved by Orbscan were better consistent with US pachymetry using an AF of 0.94. We speculate that a dynamically graded AF in reverse proportion to CCT constitutes a better approach for correcting Orbscan measurements.

  8. Refractive Surgery: Malpractice Litigation Outcomes.

    PubMed

    Custer, Benjamin L; Ballard, Steven R; Carroll, Robert B; Barnes, Scott D; Justin, Grant A

    2017-10-01

    To review data on malpractice claims related to refractive surgery to identify common allegations and injuries and financial outcomes. The WestlawNext database was reviewed for all malpractice lawsuits/settlements related to refractive eye surgery. Data evaluated included patient demographics, type of operation performed, plaintiff allegation, nature of injury, and litigation outcomes. A total of 167 cases met the inclusion criteria, of which 108 cases (64.7%) were found to be favorable and 59 cases (35.3%) unfavorable to the defendant. A total of 141 cases were tried by a jury with 108 cases (76.4%) favorable and 33 cases (23.6%) unfavorable to the defendant. Laser in situ keratomileusis was performed in 127 cases (76%). The most common allegations were negligence in treatment or surgery in 127 cases (76%) and lack of informed consent in 83 cases (49.7%). For all cases, the need for future surgery (P = 0.0001) and surgery resulting in keratoconus (P = 0.05) were more likely to favor the plaintiff. In jury verdict decisions, cases in which failure to diagnose a preoperative condition was alleged favored the defendant (P = 0.03), whereas machine malfunction (P = 0.05) favored the plaintiff. After adjustment for inflation, the overall mean award was $1,287,872. Jury verdicts and settlements led to mean awards of $1,604,801 and $826,883, respectively. Malpractice litigation in refractive surgery tends to favor the defendant. However, large awards and settlements were given in cases that were favorable to the plaintiff. The need for future surgery and surgery leading to keratoconus increased the chance of an unfavorable outcome.

  9. Boston type 1 keratoprosthesis for failed keratoplasty.

    PubMed

    Hager, Jonathan L; Phillips, David L; Goins, Kenneth M; Kitzmann, Anna S; Greiner, Mark A; Cohen, Alex W; Welder, Jeffrey D; Wagoner, Michael D

    2016-02-01

    The purpose of this study was to evaluate the outcomes of the Boston type 1 keratoprosthesis (Kpro-1) in eyes with failed keratoplasty. A retrospective review was performed of every patient treated with a Kpro-1 at a tertiary eye care center between January 1, 2008 and July 1, 2013. Eyes with a failed keratoplasty originally performed for corneal edema, trauma, or keratoconus were included in the statistical analysis. The main outcome measures were visual outcome, prosthesis retention, and postoperative complications. Twenty-four eyes met the inclusion criteria, including 13 eyes with corneal edema, 8 eyes with trauma, and 3 eyes with keratoconus. After a mean follow-up period of 28.9 months (range 7-63 months), the median best corrected visual acuity (BCVA) was 20/125. The BCVA was ≥ 20/40 in 4 (16.7 %) eyes, ≥ 20/70 in 9 (37.5 %) eyes, and ≥ 20/200 in 14 (58.3 %) eyes. Overall, the postoperative BCVA improved in 17 (70.9 %) eyes, was unchanged in 3 (12.5 %) eyes, and was worse in 4 (16.7 %) eyes. The initial Kpro-1 was retained in 22 (91.7 %) eyes, and was successfully repeated in the other 2 eyes. One or more serious prosthesis- or sight-threatening complications occurred in 8 (33.3 %) eyes. These included 1 case of wound dehiscence leading to prosthesis extrusion, 1 case of fungal keratitis leading to prosthesis extrusion, 4 cases of endophthalmitis, and 5 retinal detachments. The Boston Kpro-1 is associated with an excellent prognosis for prosthesis retention and satisfactory visual improvement in eyes with previous failed keratoplasty.

  10. [Management of corneal hydrops using air and micro-punctures].

    PubMed

    Campos Polo, R; Chacón Iglesias, J; Gamazo Carrasco, M; Mencía Bartolomé, J M; Solana Fajardo, J; García Guisado, D; Fernández Miranda, C; Bueno Álvarez-Arenas, J; Sánchez Trancón, Á; García Ardoy, E

    2015-04-01

    A 22-year- old woman with an acute hydrops and Descemet membrane detachment was managed by intracameral air injection combined with multiple corneal stromal venting incisions for the drainage of intrastromal fluid. No intraoperative complications were encountered, and the intrastromal fluid was resolved over 2 weeks. Acute corneal hydrops is a significant complication of keratoconus. If not treated, resolution usually occurs over a period of 2-4 months. The persistent oedema can cause complications, such as corneal neovascularisation, infection and corneal perforation. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Identification of four novel variants that influence central corneal thickness in multi-ethnic Asian populations.

    PubMed

    Cornes, Belinda K; Khor, Chiea Chuen; Nongpiur, Monisha E; Xu, Liang; Tay, Wan-Ting; Zheng, Yingfeng; Lavanya, Raghavan; Li, Yang; Wu, Renyi; Sim, Xueling; Wang, Ya-Xing; Chen, Peng; Teo, Yik Ying; Chia, Kee-Seng; Seielstad, Mark; Liu, Jianjun; Hibberd, Martin L; Cheng, Ching-Yu; Saw, Seang-Mei; Tai, E-Shyong; Jonas, Jost B; Vithana, Eranga N; Wong, Tien Y; Aung, Tin

    2012-01-15

    Central corneal thickness (CCT) is a highly heritable trait. Genes that significantly influence CCT can be candidate genes for common disorders in which CCT has been implicated, such as primary open-angle glaucoma (POAG) and keratoconus. Because the genetic factors controlling CCT in different Asian populations are unclear, we have built on previous work conducted on Singaporean Indians and Malays and extended our hypothesis to individuals of Chinese descent. We have followed up on all suggestive signals of association with CCT (P < 10(-4)) from the previously reported meta-analysis comprising Indians and Malays in a sample of Chinese individuals (n= 2681). In the combined sample (n= 7711), strong evidence of association was observed at four novel loci: IBTK on chromosome 6q14.1; CHSY1 on chromosome 15q26.3; and intergenic regions on chromosomes 7q11.2 and 9p23 (8.01 × 10(-11) < λ(GC) corrected P(meta) < 8.72 × 10(-8)). These four new loci explain an additional 4.3% of the total CCT variance across the sample cohorts over and above that of previously identified loci. We also extend on a previous finding at a fifth locus (AKAP13) where a new single-nucleotide polymorphism (rs1821481, P(meta) = 9.99 × 10(-9)) was found to be significantly more informative compared with the previously reported rs6496932 (P(meta) = 3.64 × 10(-5)). Performing association analysis in Asians may lead to the discovery of ethnic-specific genes that control CCT, offering further mechanistic insights into the regulation of CCT. In addition, it may also provide several candidate genes for interrogation for POAG, keratoconus and possible racial/ethnic variations. © The Author 2011. Published by Oxford University Press. All rights reserved.

  12. Clinical spectrum of KIAA2022 pathogenic variants in males: Case report of two boys with KIAA2022 pathogenic variants and review of the literature.

    PubMed

    Lorenzo, Melissa; Stolte-Dijkstra, Irene; van Rheenen, Patrick; Smith, Ronald Garth; Scheers, Tom; Walia, Jagdeep S

    2018-06-01

    KIAA2022 is an X-linked intellectual disability (XLID) syndrome affecting males more severely than females. Few males with KIAA2022 variants and XLID have been reported. We present a clinical report of two unrelated males, with two nonsense KIAA2022 pathogenic variants, with profound intellectual disabilities, limited language development, strikingly similar autistic behavior, delay in motor milestones, and postnatal growth restriction. Patient 1, 19-years-old, has long ears, deeply set eyes with keratoconus, strabismus, a narrow forehead, anteverted nares, café-au-lait spots, macroglossia, thick vermilion of the upper and lower lips, and prognathism. He has gastroesophageal reflux, constipation with delayed rectosigmoid colonic transit time, difficulty regulating temperature, several musculoskeletal issues, and a history of one grand mal seizure. Patient 2, 10-years-old, has mild dysmorphic features, therapy resistant vomiting with diminished motility of the stomach, mild constipation, cortical visual impairment with intermittent strabismus, axial hypotonia, difficulty regulating temperature, and cutaneous mastocytosis. Genetic testing identified KIAA2022 variant c.652C > T(p.Arg218*) in Patient 1, and a novel nonsense de novo variant c.2707G > T(p.Glu903*) in Patient 2. We also summarized features of all reported males with KIAA2022 variants to date. This report not only adds knowledge of a novel pathogenic variant to the KIAA2022 variant database, but also likely extends the spectrum by describing novel dysmorphic features and medical conditions including macroglossia, café-au-lait spots, keratoconus, severe cutaneous mastocytosis, and motility problems of the GI tract, which may help physicians involved in the care of patients with this syndrome. Lastly, we describe the power of social media in bringing families with rare medical conditions together. © 2018 Wiley Periodicals, Inc.

  13. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.

    PubMed

    Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S

    2013-11-01

    To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p < 0.0001) and ultrasound pachymetry (p = < .0001). Ultrasound pachymetry readings had better 95% limits of agreement with swept source optical coherence tomography than slit scanning topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p < 0.05 for all). Overall, reproducibility coefficients and intraclass correlation coefficients were significantly better with swept source optical coherence tomography for measurement of central corneal thickness, anterior best-fit sphere and, posterior best-fit sphere (all p < 0.001). Corneal thickness and elevation measurements were significantly different between swept source optical coherence tomography and slit scanning topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical

  14. Enhanced visual acuity and image perception following correction of highly aberrated eyes using an adaptive optics visual simulator.

    PubMed

    Rocha, Karolinne Maia; Vabre, Laurent; Chateau, Nicolas; Krueger, Ronald R

    2010-01-01

    To evaluate the changes in visual acuity and visual perception generated by correcting higher order aberrations in highly aberrated eyes using a large-stroke adaptive optics visual simulator. A crx1 Adaptive Optics Visual Simulator (Imagine Eyes) was used to correct and modify the wavefront aberrations in 12 keratoconic eyes and 8 symptomatic postoperative refractive surgery (LASIK) eyes. After measuring ocular aberrations, the device was programmed to compensate for the eye's wavefront error from the second order to the fifth order (6-mm pupil). Visual acuity was assessed through the adaptive optics system using computer-generated ETDRS opto-types and the Freiburg Visual Acuity and Contrast Test. Mean higher order aberration root-mean-square (RMS) errors in the keratoconus and symptomatic LASIK eyes were 1.88+/-0.99 microm and 1.62+/-0.79 microm (6-mm pupil), respectively. The visual simulator correction of the higher order aberrations present in the keratoconus eyes improved their visual acuity by a mean of 2 lines when compared to their best spherocylinder correction (mean decimal visual acuity with spherocylindrical correction was 0.31+/-0.18 and improved to 0.44+/-0.23 with higher order aberration correction). In the symptomatic LASIK eyes, the mean decimal visual acuity with spherocylindrical correction improved from 0.54+/-0.16 to 0.71+/-0.13 with higher order aberration correction. The visual perception of ETDRS letters was improved when correcting higher order aberrations. The adaptive optics visual simulator can effectively measure and compensate for higher order aberrations (second to fifth order), which are associated with diminished visual acuity and perception in highly aberrated eyes. The adaptive optics technology may be of clinical benefit when counseling patients with highly aberrated eyes regarding their maximum subjective potential for vision correction. Copyright 2010, SLACK Incorporated.

  15. Post-lens tear turbidity and visual quality after scleral lens wear.

    PubMed

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p < 0.05). The number of particles per square millimetre was eight times higher after scleral lens wear than at the beginning of wearing the lens for all groups. VA decreases in all groups after scleral lens wear (p < 0.001). All patients showed a statistical diminishing of contrast sensitivity after scleral lens wear (p < 0.05). A significant correlation was found for both turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p < 0.05). The VA decrease during the scleral lens wearing, filled with preserved saline solution, was due to the increasing post-lens tear layer turbidity. © 2017 Optometry Australia.

  16. Comparing Change in Anterior Curvature after Corneal Cross-Linking Using Scanning-Slit and Scheimpflug Technology.

    PubMed

    Lang, Paul Z; Thulasi, Praneetha; Khandelwal, Sumitra S; Hafezi, Farhad; Randleman, J Bradley

    2018-05-02

    To evaluate the correlation between anterior axial curvature difference maps following corneal cross-linking (CXL) for progressive keratoconus obtained from Scheimpflug-based tomography and Placido-based topography. Between-devices reliability analysis of randomized clinical trial data METHODS: Corneal imaging was collected at a single center institution pre-operatively and at 3, 6, and 12 months post-operatively using Scheimpflug-based tomography (Pentacam, Oculus Inc., Lynnwood, WA) and Scanning-slit, Placido-based topography (Orbscan II, Bausch & Lomb, Rochester, NY) in patients with progressive keratoconus receiving standard protocol CXL (3mW/cm 2 for 30 minutes). Regularization index (RI), absolute maximum keratometry (K Max), and change in (ΔK Max) were compared between the two devices at each time point. 51 eyes from 36 patients were evaluated at all time points. values were significantly different at all time points [56.01±5.3D Scheimpflug vs. 55.04±5.1D scanning-slit pre-operatively (p=0.003); 54.58±5.3D Scheimpflug vs. 53.12±4.9D scanning-slit at 12 months (p<0.0001)] but strongly correlated between devices (r=0.90-0.93) at all time points. The devices were not significantly different at any time point for either ΔK Max or RI but were poorly correlated at all time points (r=0.41-0.53 for ΔK Max, r=0.29-0.48 for RI). At 12 months, 95% LOA was 7.51D for absolute, 8.61D for ΔK Max, and 19.86D for RI. Measurements using Scheimpflug and scanning-slit Placido-based technology are correlated but not interchangeable. Both devices appear reasonable for separately monitoring the cornea's response to CXL; however, caution should be used when comparing results obtained with one measuring technology to the other. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Design of high power LED-based UVA emission system and a photosensitive substance for clinical application in corneal radiation

    NASA Astrophysics Data System (ADS)

    Mota, Alessandro D.; Cestari, André M.; de Oliveira, André O.; Oliveira, Anselmo G.; Terruggi, Cristina H. B.; Rossi, Giuliano; Castro, Jarbas C.; Ligabô, João. P. B.; Ortega, Tiago A.; Rosa, Tiago

    2015-09-01

    This work presents an innovative cross-linking procedure to keratoconus treatment, a corneal disease. It includes the development of an ultraviolet controlled emission portable device based on LED source and a new formulation of a photosensitive drug called riboflavin. Thus new formulation improves drug administration by its transepithelial property. The UV reaction with riboflavin in corneal tissue leads to a modification of corneal collagen fibers, turning them more rigid and dense, and consequently restraining the advance of the disease. We present the control procedures to maintain UV output power stable up to 45mw/cm2, the optical architecture that leads to a homogeneous UV spot and the new formulation of Riboflavin.

  18. Pediatric genetic disease of the cornea

    PubMed Central

    Fecarotta, Christopher M.; Huang, Wendy W.

    2014-01-01

    Our objective is to evaluate the literature regarding selected genetic diseases of the cornea, including megalocornea, keratoglobus, keratoconus, cystinosis, the mucopolysaccharidoses, sclerocornea, Peters' anomaly, familial dysautonomia, and various corneal dystrophies. The transparency of the cornea is a consequence of uniformity in both size and spacing of the collagen lamellae. The cornea's clarity depends on a delicate biochemical and structural balance; consequently, genetic disorders that disrupt either its metabolic or anatomic function can cause opacity and vision loss. Many childhood corneal diseases have a genetic etiology and are associated with known syndromes. Each disorder has unique associated set of possible complications. Prognosis often depends on the extent of opacity and disorganization of the anterior segment. Corneal transplantation has been performed for these disorders with variable success. PMID:27625877

  19. Corneal transplantation in the United Kingdom and Republic of Ireland.

    PubMed Central

    Vail, A; Gore, S M; Bradley, B A; Easty, D L; Rogers, C A

    1993-01-01

    The Corneal Transplant Follow up Study has registered 4560 corneal grafts performed in the United Kingdom and Republic of Ireland from July 1987 to June 1991. Rates of reported grafts doubled during that time. This increase was greater for surgeons and regions reporting fewer grafts, but was consistent across patient factors. Eleven of 428 consultants were responsible for over 25% of grafts, and their patients' characteristics differed significantly from others. Overall, reasons for grafting were visual only (77%), visual and other (16%), and non-visual (7%). Most frequent diagnoses were endothelial failure (38%), inflammation (26%), and keratoconus (20%). Age ranged from 2 months to 97 years, and differed markedly with diagnosis. Eighteen per cent of transplants were regrafts, and 40% were vascularised preoperatively. PMID:8218035

  20. Quantitative OCT-based longitudinal evaluation of intracorneal ring segment implantation in keratoconus.

    PubMed

    Pérez-Merino, Pablo; Ortiz, Sergio; Alejandre, Nicolas; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2013-09-09

    To characterize the geometrical properties of keratoconic corneas upon intracorneal ring segments (ICRS) implantation, using custom-developed optical coherence tomography (OCT). Ten keratoconic corneas were measured pre- and post-ICRS surgery (7, 30, and 90 days). Corneal topographic and pachymetric maps were obtained from three-dimensional (3D) images acquired with OCT, provided with custom algorithms for image analysis, distortion correction, and quantification. The 3D positioning of the ICRS was also estimated longitudinally, relative to the pupil center and iris plane. Preoperatively, the average corneal radii of curvature were 7.02 ± 0.54 mm (anterior) and 5.40 ± 0.77 mm (posterior), and the minimum corneal thickness was 384 ± 60 μm. At 90 days, the average corneal radii of curvature were 7.26 ± 0.53 mm (anterior) and 5.44 ± 0.71 mm (posterior), and the minimum corneal thickness was 396 ± 46 μm. ICRS implantation produced a significant decrease of corneal power (by 1.71 ± 1.83 diopters [D] at 90 days). Corneal irregularities (defined by high order Zernike terms of the corneal elevation maps) and the corneal thickness distribution decreased in some patients and increased in others. The 3D ICRS depth matched the planned ICRS depth well (within 23.93 ± 23.49 μm). On average, ICRS showed an overall tilt of -6.8 ± 2.6° (temporal) and -2.1 ± 0.8° (superior) at 7 days. Spectral OCT (sOCT) provided with distortion correction and analysis tools, is an excellent instrument for evaluating the changes produced by ICRS in keratoconic corneas, and for analyzing the 3D ICRS position during the follow up. ICRS produced flattening on the anterior corneal surface, although the benefit for corneal surface regularization varied across patients.

  1. Clinical results with two different pharmaceutical preparations of riboflavin in corneal cross-linking: an 18-month follow up.

    PubMed

    Hashemi, Hassan; Seyedian, Mohammad Amin; Miraftab, Mohammad; Bahrmandy, Hooman; Sabzevari, Araz; Asgari, Soheila

    2015-01-24

    Comparison of long-term clinical results of two different pharmaceutical formulations used in corneal cross-linking (CXL) in keratoconus patients. Sixty eyes of 60 keratoconus patients underwent CXL in two groups. We used riboflavin preparations from Sina Darou, Iran in group A, and Streuli Pharma, Switzerland in group B. Here we made inter-group comparison of changes in vision, refraction, Pentacam indices, corneal biomechanical indices, and endothelial cell count (ECC) 18 months after CXL. Since four patients were lost to follow-up, 56 eyes (28 eyes in each group) were compared. Mean improvement in uncorrected visual acuity (UCVA) was 0.31 ± 0.65 LogMAR (P=0.014) in group A and 0.24 ± 0.62 LogMAR (P=0.082) in group B. Best corrected visual acuity (BCVA) remained quite unchanged in both groups (P=0.774). Mean spherical refractive error reduced by 0.45 ± 1.15 diopter (D) (P=0.041) in group A and 0.27 ± 1.73 D (P=0.458) in group B (P=0.655). Cylinder error and spherical equivalent had a similar trend without any change. Max-K (P=0.006) and mean-K (P=0.044) decreased significantly more in group A compared to group B. The reduction in CCT was significantly more in group A than group B (P=0.004). Q-value was quite unchanged in both groups (P=0.704). The inter-group difference in CH reduction was borderline significant statistically (P=0.057). Changes in corneal resistance factor and endothelial cell count were not significantly different between two groups (P=0.117 and P=0.229). Clinical results of CXL with the domestic preparation of riboflavin are similar to that achieved with the Swiss made product in some aspects, and it is the preferred brand in some other aspects. This study will continue to report longer follow-up results. IRCT201212034333N2.

  2. Clinical Applications of Wavefront Refraction

    PubMed Central

    Bruce, Adrian S.; Catania, Louis J.

    2014-01-01

    ABSTRACT Purpose To determine normative reference ranges for higher-order wavefront error (HO-WFE), compare these values with those in common ocular pathologies, and evaluate treatments. Methods A review of 17 major studies on HO-WFE was made, involving data for a total of 31,605 subjects. The upper limit of the 95% confidence interval (CI) for HO-WFE was calculated from the most comprehensive of these studies using normal healthy patients aged 20 to 80 years. There were no studies identified using the natural pupil size for subjects, and for this reason, the HO-WFE was tabulated for pupil diameters of 3 to 7 mm. Effects of keratoconus, pterygium, cataract, and dry eye on HO-WFE were reviewed and treatment efficacy was considered. Results The calculated upper limit of the 95% CI for HO-WFE in a healthy normal 35-year-old patient with a mesopic pupil diameter of 6 mm would be 0.471 μm (471 nm) root-mean-square or less. Although the normal HO-WFE increases with age for a given pupil size, it is not yet completely clear how the concurrent influence of age-related pupillary miosis affects these findings. Abnormal ocular conditions such as keratoconus can induce a large HO-WFE, often in excess of 3.0 μm, particularly attributed to coma. For pterygium or cortical cataract, a combination of coma and trefoil was more commonly induced. Nuclear cataract can induce a negative spherical HO-WFE, usually in excess of 1.0 μm. Conclusions The upper limit of the 95% CI for HO-WFE root-mean-square is about 0.5 μm with normal physiological pupil sizes. With ocular pathologies, HO-WFE can be in excess of 1.0 μm, although many devices and therapeutic and surgical treatments are reported to be highly effective at minimizing HO-WFE. More accurate normative reference ranges for HO-WFE will require future studies using the subjects’ natural pupil size. PMID:25216319

  3. Changing indications for lamellar keratoplasty in Shandong, 1993 - 2008.

    PubMed

    Qu, Li-jun; Xie, Li-xin

    2010-11-01

    With the advancement of microsurgical techniques, lamellar keratoplasty (LK) has been more valued and performed to treat corneal blindness. This study aimed to evaluate the indications and changing trends for LK during the past 16 years in Shandong Eye Institute, an eye center in China. A total of 1529 eyes, predominantly from male (70.7%) patients undergoing LK between January 1993 and December 2008, were enrolled in this study. Data were collected by reviewing patient medical records for demographic characteristics, clinical diagnosis, laboratory findings and risk factors. Surgical times, initial diagnoses and causes of regrafting were recorded. All LKs were sequentially divided into period 1 (from 1993 to 2000) and period 2 (from 2001 to 2008). Rural-dwelling patients in this study numbered 1089 (71.2%); in all cases of infectious keratitis, rural patients accounted for 90.5%. The leading indications for LK were infectious keratitis (31.0%), corneal trauma (21.1%), keratoconus (18.7%), corneal dystrophy and degeneration (7.3%), regrafting (7.1%), immunologic disorders (6.7%), congenital abnormalities and corneal tumor (4.1%) and corneal scarring (3.1%). The most common subcategory of infectious keratitis was fungal keratitis (67.5%). Fusarium solani was the most morbigenous fungi. Among the patients, 73.1% of thermal burns were caused by hot molten metal, and 47.8% of alkali burns by lime. Dermoid was the most common indication for congenital abnormalities. The two main initial diagnoses from 109 regrafting cases were corneal trauma (45.9%) and Mooren's ulcer (27.5%). The most common cause for regrafting was immune rejection (35.8%). Infectious keratitis was the most common indication for LK from 16.0% in period 1 to 41.1% in period 2, followed by keratoconus (16.8%) and corneal trauma (14.5%). During the past 16 years, there have been major changes in the constituent ratios of leading indications for LK in Shangdong. Infectious keratitis has become the most

  4. Potential of FTIR spectroscopy for analysis of tears for diagnosis purposes.

    PubMed

    Travo, Adrian; Paya, Clément; Déléris, Gérard; Colin, Joseph; Mortemousque, Bruno; Forfar, Isabelle

    2014-04-01

    It has been widely reported that the tear film, which is crucially important as a protective barrier of the eye, undergoes biochemical changes as a result of a wide range of ocular pathology. This tends to suggest the possibility of early detection of ocular diseases on the basis of biochemical analysis of tears. However, studies of tears by conventional methods of biomolecular and biochemical analysis are often limited by methodological difficulties. Moreover, such analysis could not be applied in the clinic, where structural and morphological analyses by, mainly, slit-lamp biomicroscopy remains the recommended method. In this study, we assessed, for the first time, the potential of FTIR spectroscopy combined with advanced chemometric processing of spectral data for analysis of raw tears for diagnosis purposes. We first optimized sampling and spectral acquisition (tears collection method, tear sample volume, and preservation of the samples) for accurate spectral measurement. On the basis of the results, we focused our study on the possibility of discriminating tears from normal individuals from those of patients with different ocular pathologies, and showed that the most discriminating spectral range is that corresponding to variations of CH2 and CH3 of lipid aliphatic chains. We also report more subtle discrimination of tears from patients with keratoconus and those from patients with non-specific inflammatory ocular diseases, on the basis of variations in spectral ranges attributed notably to lipid and carbohydrate vibrations. Finally, we also succeeded in distinguishing tears from patients with early-stage and late-stage keratoconus on the basis of spectral features attributed to protein structure. Therefore, this study strongly suggests that FTIR spectral analysis of tears could be developed as a valuable and cost-saving tool for biochemical-based detection of ocular diseases, potentially before the appearance of the first morphological signs of diseases

  5. Deep lamellar keratoplasty on air with lyophilised tissue.

    PubMed Central

    Chau, G K; Dilly, S A; Sheard, C E; Rostron, C K

    1992-01-01

    Deep lamellar keratoplasty on air involves injecting air into the corneal stroma to expand it to several times its normal thickness. This method is designed to facilitate dissection of the deep stroma and reduce the risk of perforation of Descemet's membrane when carrying out deep lamellar keratoplasty. We have modified the technique by using prelathed freeze-dried donor tissue and report our results in a series of patients with corneal stromal scarring owing to a variety of corneal problems, namely, keratoconus, pterygium, and herpes zoster ophthalmicus. All patients achieved best corrected postoperative visual acuity of 6/12 or better without problems associated with graft failure or rejection. Histopathological examination of corneal tissue following air injection showed surgical emphysema within the cornea and separation of deep stromal fibres from the underlying Descemet's membrane. Images PMID:1477037

  6. Combined microwave heating and surface cooling of the cornea.

    PubMed

    Trembly, B S; Keates, R H

    1991-01-01

    We investigated a nonsurgical means of reshaping the cornea to correct hyperopia, keratoconus, or myopia. The object was to heat the central stroma of the cornea to the shrinkage temperature of collagen, 55-58 degrees C. The heating device was an open-ended, coaxial, near-field applicator driven at 2450 MHz; it incorporates cooling of the cornea surface by flow of saline. We investigated the system theoretically by computing the 2-D, axisymmetric temperature distribution with the finite element method. We investigated the system experimentally by heating excised steer corneas. Histology showed the system could shrink the stroma to a depth of 0.6 mm while sparing the epithelium in 75% of cases; the diameter of shrinkage was 1.3 mm. Theory predicted a significantly deeper and narrower region of shrinkage than was observed.

  7. Corneal collagen crosslinking and pigment dispersion syndrome.

    PubMed

    LaHood, Benjamin R; Moore, Sacha

    2017-03-01

    We describe the case of a keratoconus patient with pigment dispersion syndrome (PDS) who was treated for progressive corneal ectasia with corneal collagen crosslinking (CXL). Pigment dispersion syndrome has been shown to have associated morphologic changes of the corneal endothelium. Corneal CXL has the potential to cause toxicity to the corneal endothelium, and adjacent pigment might increase the likelihood of damage. In this case, the presence of PDS had no detrimental effect on the outcome of treatment, and no complications were observed at 12 months follow-up, indicating that it may be safe to perform corneal CXL in the setting of PDS. This is an important observation as the number of indications for corneal CXL grows. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Collagen Cross-Linking Using Riboflavin and Ultraviolet-A for Corneal Thinning Disorders

    PubMed Central

    Pron, G; Ieraci, L; Kaulback, K

    2011-01-01

    Executive Summary Objective The main objectives for this evidence-based analysis were to determine the safety and effectiveness of photochemical corneal collagen cross-linking with riboflavin (vitamin B2) and ultraviolet-A radiation, referred to as CXL, for the management of corneal thinning disease conditions. The comparative safety and effectiveness of corneal cross-linking with other minimally invasive treatments such as intrastromal corneal rings was also reviewed. The Medical Advisory Secretariat (MAS) evidence-based analysis was performed to support public financing decisions. Subject of the Evidence-Based Analysis The primary treatment objective for corneal cross-linking is to increase the strength of the corneal stroma, thereby stabilizing the underlying disease process. At the present time, it is the only procedure that treats the underlying disease condition. The proposed advantages for corneal cross-linking are that the procedure is minimally invasive, safe and effective, and it can potentially delay or defer the need for a corneal transplant. In addition, corneal cross-linking does not adversely affect subsequent surgical approaches, if they are necessary, or interfere with corneal transplants. The evidence for these claims for corneal cross-linking in the management of corneal thinning disorders such as keratoconus will be the focus of this review. The specific research questions for the evidence review were as follows: Technical: How technically demanding is corneal cross-linking and what are the operative risks? Safety: What is known about the broader safety profile of corneal cross-linking? Effectiveness - Corneal Surface Topographic Affects: What are the corneal surface remodeling effects of corneal cross-linking? Do these changes interfere with subsequent interventions, particularly corneal transplant known as penetrating keratoplasty (PKP)? Effectiveness -Visual Acuity: What impacts does the remodeling have on visual acuity? Are these impacts

  9. Collagen cross-linking using riboflavin and ultraviolet-a for corneal thinning disorders: an evidence-based analysis.

    PubMed

    Pron, G; Ieraci, L; Kaulback, K

    2011-01-01

    The main objectives for this evidence-based analysis were to determine the safety and effectiveness of photochemical corneal collagen cross-linking with riboflavin (vitamin B(2)) and ultraviolet-A radiation, referred to as CXL, for the management of corneal thinning disease conditions. The comparative safety and effectiveness of corneal cross-linking with other minimally invasive treatments such as intrastromal corneal rings was also reviewed. The Medical Advisory Secretariat (MAS) evidence-based analysis was performed to support public financing decisions. SUBJECT OF THE EVIDENCE-BASED ANALYSIS: The primary treatment objective for corneal cross-linking is to increase the strength of the corneal stroma, thereby stabilizing the underlying disease process. At the present time, it is the only procedure that treats the underlying disease condition. The proposed advantages for corneal cross-linking are that the procedure is minimally invasive, safe and effective, and it can potentially delay or defer the need for a corneal transplant. In addition, corneal cross-linking does not adversely affect subsequent surgical approaches, if they are necessary, or interfere with corneal transplants. The evidence for these claims for corneal cross-linking in the management of corneal thinning disorders such as keratoconus will be the focus of this review. The specific research questions for the evidence review were as follows: TECHNICAL: How technically demanding is corneal cross-linking and what are the operative risks? What is known about the broader safety profile of corneal cross-linking?Effectiveness - Corneal Surface Topographic Affects:What are the corneal surface remodeling effects of corneal cross-linking?Do these changes interfere with subsequent interventions, particularly corneal transplant known as penetrating keratoplasty (PKP)?Effectiveness -Visual Acuity:What impacts does the remodeling have on visual acuity?Are these impacts predictable, stable, adjustable and

  10. Simulation of Ophthalmic Alterations at the Arctic, Antarctica and the International Space Station for Long-Duration Spaceflight

    NASA Astrophysics Data System (ADS)

    De Morais Mendonca Teles, Antonio; Gonçalves, Cristiane

    2016-07-01

    Well, we propose a series of long-period medical simulations in scientific bases at the Arctic, at Antarctica and aboard the International Space Station (ISS), involving natural ophthalmic diseases such as radiation, solar and trauma retinopathy, keratoconus, cataract, glaucoma, etc., and ophthalmic alterations by accidental injuries. These natural diseases, without a previous diagnosis, specially those specific retinopathy, appear after 1 month to 1.5 year, in average. Such studies will be valuable for the human deep-space exploration because during long-duration spaceflight, such as staying at the ISS, a Moon base and a manned trip to planet Mars, requires several months within such environments, and during such periods ophthalmic diseases and accidents might eventually occur, which could seriously affect the 'round-the-clock' work schedule of the astronauts and the long-duration spaceflight manned program.

  11. Corneal topography with high-speed swept source OCT in clinical examination

    PubMed Central

    Karnowski, Karol; Kaluzny, Bartlomiej J.; Szkulmowski, Maciej; Gora, Michalina; Wojtkowski, Maciej

    2011-01-01

    We present the applicability of high-speed swept source (SS) optical coherence tomography (OCT) for quantitative evaluation of the corneal topography. A high-speed OCT device of 108,000 lines/s permits dense 3D imaging of the anterior segment within a time period of less than one fourth of second, minimizing the influence of motion artifacts on final images and topographic analysis. The swept laser performance was specially adapted to meet imaging depth requirements. For the first time to our knowledge the results of a quantitative corneal analysis based on SS OCT for clinical pathologies such as keratoconus, a cornea with superficial postinfectious scar, and a cornea 5 months after penetrating keratoplasty are presented. Additionally, a comparison with widely used commercial systems, a Placido-based topographer and a Scheimpflug imaging-based topographer, is demonstrated. PMID:21991558

  12. A comparison of lamellar and penetrating keratoplasty outcomes: a registry study.

    PubMed

    Coster, Douglas J; Lowe, Marie T; Keane, Miriam C; Williams, Keryn A

    2014-05-01

    To investigate changing patterns of practice of keratoplasty in Australia, graft survival, visual outcomes, the influence of experience, and the surgeon learning curve for endothelial keratoplasty. Observational, prospective cohort study. From a long-standing national corneal transplantation register, 13 920 penetrating keratoplasties, 858 deep anterior lamellar keratoplasties (DALKs), and 2287 endokeratoplasties performed between January 1996 and February 2013 were identified. Kaplan-Meier functions were used to assess graft survival and surgeon experience, the Pearson chi-square test was used to compare visual acuities, and linear regression was used to examine learning curves. Graft survival. The total number of corneal grafts performed annually is increasing steadily. More DALKs but fewer penetrating grafts are being performed for keratoconus, and more endokeratoplasties but fewer penetrating grafts are being performed for Fuchs' dystrophy and pseudophakic bullous keratopathy. In 2012, 1482 grafts were performed, compared with 955 in 2002, translating to a requirement for 264 extra corneal donors across the country in 2012. Comparing penetrating grafts and DALKs performed for keratoconus over the same era, both graft survival (P <0.001) and visual outcomes (P <0.001) were significantly better for penetrating grafts. Survival of endokeratoplasties performed for Fuchs' dystrophy or pseudophakic bullous keratopathy was poorer than survival of penetrating grafts for the same indications over the same era (P <0.001). Visual outcomes were significantly better for penetrating grafts than for endokeratoplasties performed for Fuchs' dystrophy (P <0.001), but endokeratoplasties achieved better visual outcomes than penetrating grafts for pseudophakic bullous keratopathy (P <0.001). Experienced surgeons (>100 registered keratoplasties) achieved significantly better survival of endokeratoplasties (P <0.001) than surgeons who had performed fewer grafts (<100

  13. Recent Innovations in Collagen Corneal Cross-linking; a Mini Review.

    PubMed

    Vastardis, Iraklis; Pajic-Eggspuehler, Brigitte; Nichorlis, Charis; Mueller, Jörg; Pajic, Bojan

    2017-01-01

    The introduction of corneal cross-linking (CXL) with ultraviolet-A (UVA) and Riboflavin photosensitizer (Vit B 2 ) from Seiler et al. , revolutionized the treatment of Keratoconus and other corneal ectatic diseases. Today, the commonly known epithelium off Dresden protocol is in clinical use for the last 15 years with great success and regarded by many as the golden standard. With several studies demonstrating its simplicity, efficacy and safety this revolutionary method, paved the way for new therapies and strategies in the treatment of corneal ectatic diseases and changed our understanding in corneal biomechanics. Recent scientific and technological advances enabled the creation of various modifications of the initial CXL protocol and the formation of new ones. This work highlights the recent advances of CXL, such as the role of oxygen, higher fluence and shorter irradiation times as well as the various clinical applications and updates of this method.

  14. Acute corneal hydrops mimicking full thickness perforation.

    PubMed

    Ch'ng, S W; Pillai, M B; Aazeem, S; Tu, K L

    2012-05-11

    A 26-year-old Caucasian female with keratoconus presented with an acutely painful and red left eye. Visual acuity on presentation was 3/60. Slit lamp examination revealed localised Descemet's membrane break with iris partially plugging it. There was a bulging stromal cyst which would intermittently flatten and reform. The appearance when the cyst was flattened mimicked a full thickness corneal perforation. However, no obvious overlying epithelial defect was detected and an intermittent leakage through micro-perforations in the corneal epithelium was the probable cause of the variable appearance. The anterior chamber reformed and iris plug freed following an insertion of a bandage contact lens and taped eyelid. On follow-up, the Descement's membrane had healed with visual acuity improving to 6/18. Our case illustrates the importance of identifying corneal hydrops mimicking a full thickness perforation as conservative management has a greater chance of recovery.

  15. The concept of geodesic curvature applied to optical surfaces.

    PubMed

    Barbero, Sergio

    2015-07-01

    To propose geodesic curvature as a metric to characterise how an optical surface locally differs from axial symmetry. To derive equations to evaluate geodesic curvatures of arbitrary surfaces expressed in polar coordinates. The concept of geodesic curvature is explained in detail as compared to other curvature-based metrics. Starting with the formula representing a surface as function of polar coordinates, an equation for the geodesic curvature is obtained depending only on first and second radial and first order angular derivatives of the surface function. The potential of the geodesic curvature is illustrated using different surface tests. Geodesic curvature reveals local axial asymmetries more sharply than other types of curvatures such as normal curvatures. Geodesic curvature maps could be used to characterise local axial asymmetries for relevant optometry applications such as corneal topography anomalies (keratoconus) or ophthalmic lens metrology. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  16. Air-guided manual deep lamellar keratoplasty.

    PubMed

    Caporossi, A; Simi, C; Licignano, R; Traversi, C; Balestrazzi, A

    2004-01-01

    To evaluate the efficacy of a new modified technique of deep lamellar keratoplasty (DLK). Nine eyes of eight patients with keratoconus of moderate degree were included. All patients underwent DLK with manual dissection from a limbal side port after an air bubble injection in the anterior chamber. The patients underwent a complete ophthalmologic examination 6 months after the suture removal, evaluating best-corrected visual acuity, corneal thickness, endothelial cell count, and topographic astigmatism. One case (11.1%) was converted to penetrating keratoplasty because of microperforation. In the eight successful cases, 7 eyes (77.8%) achieved 20/30 or better visual acuity 6 months after suture removal. Mean postoperative pachymetry was 604.76 microm (SD 46.76). Specular microscopy 6 months after suture removal revealed average endothelial cell count of 2273/mm2 (SD 229). This modified DLK technique is a safe and effective procedure and could facilitate, after a short learning curve, this kind of surgery with a low risk of conversion to penetrating keratoplasty.

  17. Physical Aspects of Photodynamic Corneal Collagen Crosslinking

    NASA Astrophysics Data System (ADS)

    Kornfield, Julia

    2012-02-01

    Healthy vision depends on the stability of the shape of the cornea, which provides most of the lens power of the optical system of the eye. Diseases in which the cornea progressively undergoes irregular deformation over time (e.g., keratoconus) can be treated clinically by inducing additional protein-protein crosslinks using a photosensitizing drug and a tailored dose of light. Unfortunately, the treatment moving through clinical trials is toxic to cells in and on the cornea. A path to a safer treatment is offered by the nanostructure of the corneal stroma---reminiscent of a HEX phase in block copolymers with 30nm diameter collagen cylinders spaced 60nm center-to-center in a hydrogel matrix of proteoglycans and water. We show that using a photosensitizing drug that sequesters itself in the collagen fibrils can minimize the toxicity of therapeutic protein-protein cross-linking. Photorheology and transport measurements are used to quantify the parameters of a simple physical model that is useful for optimizing clinical protocols.

  18. Corneal aberrations in keratoconic eyes: influence of pupil size and centering

    NASA Astrophysics Data System (ADS)

    Comastri, S. A.; Perez, L. I.; Pérez, G. D.; Martin, G.; Bianchetti, A.

    2011-01-01

    Ocular aberrations vary among subjects and under different conditions and are commonly analyzed expanding the wavefront aberration function in Zernike polynomials. In previous articles, explicit analytical formulas to transform Zernike coefficients of up to 7th order corresponding to an original pupil into those related to a contracted displaced new pupil are obtained. In the present paper these formulas are applied to 20 keratoconic corneas of varying severity. Employing the SN CT1000 topographer, aberrations of the anterior corneal surface for a pupil of semi-diameter 3 mm centered on the keratometric axis are evaluated, the relation between the higher-order root mean square wavefront error and the index KISA% characterizing keratoconus is studied and the size and centering of the ocular photopic natural pupil are determined. Using these data and the transformation formulas, new coefficients associated to the photopic pupil size are computed and their variation when coordinates origin is shifted from the keratometric axis to the ocular pupil centre is analyzed.

  19. Iron homeostasis and eye disease

    PubMed Central

    Loh, Allison; Hadziahmetovic, Majda; Dunaief, Joshua L.

    2009-01-01

    Summary Iron is necessary for life, but excess iron can be toxic to tissues. Iron is thought to damage tissues primarily by generating oxygen free radicals through the Fenton reaction. We present an overview of the evidence supporting iron's potential contribution to a broad range of eye disease using an anatomical approach. Firstly, iron can be visualized in the cornea as iron lines in the normal aging cornea as well as in diseases like keratoconus and pterygium. In the lens, we present the evidence for the role of oxidative damage in cataractogenesis. Also, we review the evidence that iron may play a role in the pathogenesis of the retinal disease age-related macular degeneration. Although currently there is no direct link between excess iron and development of optic neuropathies, ferrous iron's ability to form highly reactive oxygen species may play a role in optic nerve pathology. Lastly, we discuss recent advances in prevention and therapeutics for eye disease with antioxidants and iron chelators,. PMID:19059309

  20. Developments in Ocular Genetics: 2013 Annual Review

    PubMed Central

    Aboobakar, Inas F.; Allingham, R. Rand

    2014-01-01

    Purpose To highlight major advancements in ocular genetics from the year 2013. Design Literature review. Methods A literature search was conducted on PubMed to identify articles pertaining to genetic influences on human eye diseases. This review focuses on manuscripts published in print or online in the English language between January 1, 2013 and December 31, 2013. A total of 120 papers from 2013 were included in this review. Results Significant progress has been made in our understanding of the genetic basis of a broad group of ocular disorders, including glaucoma, age-related macular degeneration, cataract, diabetic retinopathy, keratoconus, Fuchs’ endothelial dystrophy, and refractive error. Conclusions The latest next-generation sequencing technologies have become extremely effective tools for identifying gene mutations associated with ocular disease. These technological advancements have also paved the way for utilization of genetic information in clinical practice, including disease diagnosis, prediction of treatment response and molecular interventions guided by gene-based knowledge. PMID:25097799

  1. The Role of the Reactive Oxygen Species and Oxidative Stress in the Pathomechanism of the Age-Related Ocular Diseases and Other Pathologies of the Anterior and Posterior Eye Segments in Adults

    PubMed Central

    Nita, Małgorzata; Grzybowski, Andrzej

    2016-01-01

    The reactive oxygen species (ROS) form under normal physiological conditions and may have both beneficial and harmful role. We search the literature and current knowledge in the aspect of ROS participation in the pathogenesis of anterior and posterior eye segment diseases in adults. ROS take part in the pathogenesis of keratoconus, Fuchs endothelial corneal dystrophy, and granular corneal dystrophy type 2, stimulating apoptosis of corneal cells. ROS play a role in the pathogenesis of glaucoma stimulating apoptotic and inflammatory pathways on the level of the trabecular meshwork and promoting retinal ganglion cells apoptosis and glial dysfunction in the posterior eye segment. ROS play a role in the pathogenesis of Leber's hereditary optic neuropathy and traumatic optic neuropathy. ROS induce apoptosis of human lens epithelial cells. ROS promote apoptosis of vascular and neuronal cells and stimulate inflammation and pathological angiogenesis in the course of diabetic retinopathy. ROS are associated with the pathophysiological parainflammation and autophagy process in the course of the age-related macular degeneration. PMID:26881021

  2. Spontaneous Corneal Hydrops in a Patient with a Corneal Ulcer

    PubMed Central

    Batawi, Hatim; Kothari, Nikisha; Camp, Andrew; Bernhard, Luis; Karp, Carol L.; Galor, Anat

    2016-01-01

    Purpose We report the case of a 77-year-old man with no history of keratoconus or other ectatic disorders who presented with corneal hydrops in the setting of a corneal ulcer. The risk factors, pathogenesis and treatment options of corneal hydrops are discussed. Method This is an observational case report study. Results A 77-year-old man presented with a 1-day history of severe pain, redness, mucous discharge and photophobia in the right eye. A slit-lamp examination of the right eye showed an area of focal corneal edema and protrusion. Within the area of edema and protrusion, there was an infiltrate with an overlying epithelial defect consistent with an infectious corneal ulcer. The Seidel test showed no leakage, so a clinical diagnosis of corneal hydrops associated with nonperforated corneal ulcer was made. With appropriate antibiotic treatment, the corneal ulcer and hydrops both resolved over a 1-month period. Conclusion Corneal hydrops can occur in the setting of corneal infections. PMID:26889160

  3. Spontaneous Corneal Hydrops in a Patient with a Corneal Ulcer.

    PubMed

    Batawi, Hatim; Kothari, Nikisha; Camp, Andrew; Bernhard, Luis; Karp, Carol L; Galor, Anat

    2016-01-01

    We report the case of a 77-year-old man with no history of keratoconus or other ectatic disorders who presented with corneal hydrops in the setting of a corneal ulcer. The risk factors, pathogenesis and treatment options of corneal hydrops are discussed. This is an observational case report study. A 77-year-old man presented with a 1-day history of severe pain, redness, mucous discharge and photophobia in the right eye. A slit-lamp examination of the right eye showed an area of focal corneal edema and protrusion. Within the area of edema and protrusion, there was an infiltrate with an overlying epithelial defect consistent with an infectious corneal ulcer. The Seidel test showed no leakage, so a clinical diagnosis of corneal hydrops associated with nonperforated corneal ulcer was made. With appropriate antibiotic treatment, the corneal ulcer and hydrops both resolved over a 1-month period. Corneal hydrops can occur in the setting of corneal infections.

  4. Corneal graft rejection in African Americans at Howard University Hospital

    PubMed Central

    Ferdinand, Larry; Ngakeng, Vanessa; Copeland, Robert A.

    2011-01-01

    Purpose There is scarcity of data in the literature on cornel graft rejection rate in patients exclusively of African ancestry. The purpose of this study was to evaluate the rejection rate of corneal transplant surgery performed at Howard University Hospital on such patients over a 15 year period. Design A retrospective evaluation was performed of the cornea graft rejection and corneal graft failure rate in 125 penetrating keratoplasties (PKPs) done by one corneal specialist at Howard University Hospital from January 1, 1990 to August 31, 2005. Methods Of the 125 patients, 62 were eliminated from the study because of re-grafted eyes, non-African descent, primary graft failures, follow-up less than 1 month and lack of availability of charts. This study, therefore, studied and recorded data from 63 penetrating keratoplasties of 63 eyes from 60 patients. Results Episodes of graft rejection were documented in 23 eyes (36.5% of cases). Nine out of the 23 graft rejections manifested to secondary graft failure (39%). Overall, there were nine out of the 63 PKPs (14.3%) that resulted in secondary graft failure over the past 15 years. The major diagnostic categories were bullous keratopathy 24 (38%), keratoconus 10 (15.8%), Fuch’s dystrophy 4 (6.3%), other 20 (31.7%). Of the cases with episodes of rejection and failure, 4.3% and none were attributable to keratoconus, 30.4% and 22.2% for bullous keratopathy, and 8.7% and 22.2% for Fuch’s dystrophy, respectively. Also, best visual acuity was looked at in patients with rejection episodes. None of the patients had a pre-op visual acuity 20/40 or better; however, post-op PKP 2 (8.7%) of patients achieved 20/40 or better. Also, 4 (17.4%) of patients had a pre-op visual acuity between 20/50 and 20/150, but post-op PKP best visual acuity between 20/50 and 20/150 was increased to 9 (39.1%). Conclusion At 36% the prevalence of corneal graft rejection was one of the highest in the reported literature. But only 14% of those

  5. Corneal graft rejection in African Americans at Howard University Hospital.

    PubMed

    Ferdinand, Larry; Ngakeng, Vanessa; Copeland, Robert A

    2011-07-01

    There is scarcity of data in the literature on cornel graft rejection rate in patients exclusively of African ancestry. The purpose of this study was to evaluate the rejection rate of corneal transplant surgery performed at Howard University Hospital on such patients over a 15 year period. A retrospective evaluation was performed of the cornea graft rejection and corneal graft failure rate in 125 penetrating keratoplasties (PKPs) done by one corneal specialist at Howard University Hospital from January 1, 1990 to August 31, 2005. Of the 125 patients, 62 were eliminated from the study because of re-grafted eyes, non-African descent, primary graft failures, follow-up less than 1 month and lack of availability of charts. This study, therefore, studied and recorded data from 63 penetrating keratoplasties of 63 eyes from 60 patients. Episodes of graft rejection were documented in 23 eyes (36.5% of cases). Nine out of the 23 graft rejections manifested to secondary graft failure (39%). Overall, there were nine out of the 63 PKPs (14.3%) that resulted in secondary graft failure over the past 15 years. The major diagnostic categories were bullous keratopathy 24 (38%), keratoconus 10 (15.8%), Fuch's dystrophy 4 (6.3%), other 20 (31.7%). Of the cases with episodes of rejection and failure, 4.3% and none were attributable to keratoconus, 30.4% and 22.2% for bullous keratopathy, and 8.7% and 22.2% for Fuch's dystrophy, respectively. Also, best visual acuity was looked at in patients with rejection episodes. None of the patients had a pre-op visual acuity 20/40 or better; however, post-op PKP 2 (8.7%) of patients achieved 20/40 or better. Also, 4 (17.4%) of patients had a pre-op visual acuity between 20/50 and 20/150, but post-op PKP best visual acuity between 20/50 and 20/150 was increased to 9 (39.1%). At 36% the prevalence of corneal graft rejection was one of the highest in the reported literature. But only 14% of those episodes resulted in graft failure which is one of

  6. Intraoperative corneal thickness measurements during corneal collagen cross-linking with isotonic riboflavin solution without dextran in corneal ectasia.

    PubMed

    Cınar, Yasin; Cingü, Abdullah Kürşat; Sahin, Alparslan; Türkcü, Fatih Mehmet; Yüksel, Harun; Caca, Ihsan

    2014-03-01

    Abstract Objective: To monitor the changes in corneal thickness during the corneal collagen cross-linking procedure by using isotonic riboflavin solution without dextran in ectatic corneal diseases. The corneal thickness measurements were obtained before epithelial removal, after epithelial removal, following the instillation of isotonic riboflavin solution without dextran for 30 min, and after 10 min of ultraviolet A irradiation. Eleven eyes of eleven patients with progressive keratoconus (n = 10) and iatrogenic corneal ectasia (n = 1) were included in this study. The mean thinnest pachymetric measurements were 391.82 ± 30.34 µm (320-434 µm) after de-epithelialization of the cornea, 435 ± 21.17 µm (402-472 µm) following 30 min instillation of isotonic riboflavin solution without dextran and 431.73 ± 20.64 µm (387-461 µm) following 10 min of ultraviolet A irradiation to the cornea. Performing corneal cross-linking procedure with isotonic riboflavin solution without dextran might not induce corneal thinning but a little swelling throughout the procedure.

  7. Characterization of elasticity and hydration of composite hydrogel based on collagen-iota carrageenan as a corneal tissue engineering

    NASA Astrophysics Data System (ADS)

    Rinawati, M.; Triastuti, J.; Pursetyo, K. T.

    2018-04-01

    The cornea is a refractive element of the eye that serves to continue the stimulation of light into the eye it has a clear, transparent, elastic and relatively thick tissue. Factors caused corneal blindness, are dystrophy, keratoconus, corneal scaring. Hydrogels can be made from polysaccharide derivatives that have gelation properties such as iota carrageenan. Therefore, it is a need to develop composite hydrogel based collagen-iota carragenan as an engineeried corneal tissue with high elasticity and hydration properties. Collagen hydrogel has a maximum water content an has equlibrium up to 40 %, less than the human cornea, 81 % and under normal hydration conditions, the human cornea can transmit 87 % of visible light. In addition, the refractive index on the surface of the cornea with air is 1.375-1.380. Based on this study, it is necessary to conduct research on the development and composition of hydrogel composite collagen-iota carrageen hydrogen based on. The best result was K5 (5:5) treatment, which has the equilibrium water content of 87.07 % and viscosity of 10.7346 Pa.s.

  8. In Vivo Corneal High-Speed, Ultra–High-Resolution Optical Coherence Tomography

    PubMed Central

    Christopoulos, Viki; Kagemann, Larry; Wollstein, Gadi; Ishikawa, Hiroshi; Gabriele, Michelle L.; Wojtkowski, Maciej; Srinivasan, Vivek; Fujimoto, James G.; Duker, Jay S.; Dhaliwal, Deepinder K.; Schuman, Joel S.

    2007-01-01

    Objective: To introduce new corneal high-speed, ultra–high-resolution optical coherence tomography (hsUHR-OCT) technology that improves the evaluation of complicated and uncomplicated cataract, corneal, and refractive surgical procedures. Design: This case series included a control subject and 9 eyes of 8 patients who had undergone phacoemulsification, Descemet membrane stripping endokeratoplasty, corneal implantation for keratoconus, and complicated and uncomplicated laser in situ keratomileusis. These eyes underwent imaging using a prototype ophthalmic hsUHR-OCT system. All the scans were compared with conventional slitlamp biomicroscopy. Results: Cross-sectional hsUHR-OCT imaging allowed in vivo differentiation of corneal layers and existing pathologic abnormalities at ultrahigh axial image resolution. These images illustrate the various incisional and refractive interfaces created with corneal procedures. Conclusions: The magnified view of the cornea using hsUHR-OCT is helpful in conceptualizing and understanding basic and complicated clinical pathologic features; hsUHR-OCT has the potential to become a powerful, noninvasive clinical corneal imaging modality that can enhance surgical management. Trial Registration: clinicaltrials.gov Identifier: NCT00343473 PMID:17698748

  9. Medical applications of atomic force microscopy and Raman spectroscopy.

    PubMed

    Choi, Samjin; Jung, Gyeong Bok; Kim, Kyung Sook; Lee, Gi-Ja; Park, Hun-Kuk

    2014-01-01

    This paper reviews the recent research and application of atomic force microscopy (AFM) and Raman spectroscopy techniques, which are considered the multi-functional and powerful toolkits for probing the nanostructural, biomechanical and physicochemical properties of biomedical samples in medical science. We introduce briefly the basic principles of AFM and Raman spectroscopy, followed by diagnostic assessments of some selected diseases in biomedical applications using them, including mitochondria isolated from normal and ischemic hearts, hair fibers, individual cells, and human cortical bone. Finally, AFM and Raman spectroscopy applications to investigate the effects of pharmacotherapy, surgery, and medical device therapy in various medicines from cells to soft and hard tissues are discussed, including pharmacotherapy--paclitaxel on Ishikawa and HeLa cells, telmisartan on angiotensin II, mitomycin C on strabismus surgery and eye whitening surgery, and fluoride on primary teeth--and medical device therapy--collagen cross-linking treatment for the management of progressive keratoconus, radiofrequency treatment for skin rejuvenation, physical extracorporeal shockwave therapy for healing of Achilles tendinitis, orthodontic treatment, and toothbrushing time to minimize the loss of teeth after exposure to acidic drinks.

  10. Analysis of corneal topography in patients with pure microphthalmia in Eastern China.

    PubMed

    Hu, Pei-Hong; Gao, Gui-Ping; Yu, Yao; Pei, Chong-Gang; Zhou, Qiong; Huang, Xin; Zhang, Ying; Shao, Yi

    2015-12-01

    To determine the typical corneal changes in pure microphthalmia using a corneal topography system and identify characteristics that may assist in early diagnosis. Patients with pure microphthalmia and healthy control subjects underwent corneal topography analysis (Orbscan IIZ® Corneal Topography System; Bausch and Lomb, Bridgewater, NJ, USA) to determine degree of corneal astigmatism (mean A), simulation of corneal astigmatism (sim A), mean keratometry (mean K), simulated keratometry (sim K), irregularities in the 3 - and 5-mm zone, and mean thickness of nine distinct corneal regions. Patients with pure microphthalmia (n = 12) had significantly higher mean K, sim K, mean A, sim A, 3.0 mm irregularity and 5.0 mm irregularity, and exhibited significantly more false keratoconus than controls (n = 12). There was a significant between-group difference in the morphology of the anterior corneal surface and the central curvature of the cornea. Changes in corneal morphology observed in this study could be useful in borderline situations to confirm the diagnosis of pure microphthalmia. © The Author(s) 2015.

  11. Corneal complications of vernal keratoconjunctivitis.

    PubMed

    Solomon, Abraham

    2015-10-01

    Vernal keratoconjunctivitis (VKC) is a severe bilateral chronic allergic inflammatory disease of the ocular surface. In most of the cases, the disease is limited to the tarsal conjunctiva and to the limbus. However, in the more severe cases, the cornea may be involved, leading to potentially sight threatening complications. Prompt recognition of these complications is crucial in the management of VKC, which is one of the most severe ocular allergic diseases. A vicious cycle of inflammation occurs as a result of a set of reciprocal interactions between the conjunctiva and the cornea, which results in damage to the corneal epithelium and corneal stoma, and to the formation of shield ulcers and plaques, infectious keratitis, keratoconus, scarring, and limbal stem cell deficiency. These corneal complications can cause permanent decrease or loss of vision in children suffering from VKC. Corneal complications in VKC are the result of an on-going process of uncontrolled inflammation. Proper recognition of the corneal complications in VKC is crucial, as most of these can be managed or prevented by a combination of medical and surgical measures.

  12. Anterior Eye Imaging with Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  13. Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.

    PubMed

    Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S

    2017-01-01

    The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.

  14. Comparison of central corneal thickness measurements with a rotating scheimpflug camera, a specular microscope, optical low-coherence reflectometry, and ultrasound pachymetry in keratoconic eyes.

    PubMed

    Cinar, Yasin; Cingu, Abdullah Kursat; Turkcu, Fatih Mehmet; Cinar, Tuba; Sahin, Alparslan; Yuksel, Harun; Ari, Seyhmus

    2015-03-01

    To compare central corneal thickness (CCT) measurements with a rotating Scheimpflug camera (RSC), noncontact specular microscopy (SM), optical low-coherence reflectometry (OLCR), and ultrasonic pachymetry (UP) in keratoconus (KC) patients. In this prospective study, four CCT measurements taken with an RSC, SM, OLCR, and UP were compared in 81 eyes of 44 consecutive KC patients. The KC patients were divided into four subgroups according to Amsler-Krumeich's KC classification. The RSC and UP measurements of the CCT were not statistically significant in all the groups. Comparison of the SM vs. the OLCR measurements yielded statistically significant differences in all the KC patients and in all KC stages. In all the KC patients, RSC and OLCR showed a high correlation coefficient factor (r = 0.87, p = 0.000). CCT measurements with RSC are comparable to those achieved with UP. Compared with the other devices, according to SM measurements, the central cornea is thicker in all keratoconic eyes and in all KC grades, and it is thinner according to OLCR. RSC, UP, SM, and OLCR should not be used interchangeably in keratoconic eyes.

  15. Scleral contact lenses for the management of complicated ptosis.

    PubMed

    Katsoulos, Konstantinos; Rallatos, Gerasimos Livir; Mavrikakis, Ioannis

    2018-06-01

    To present the management of three patients suffering from ptosis of various etiologies, with scleral contact lenses. Three patients (five eyes) with ptosis resulting from levator dehiscence due to long-term rigid gas permeable contact lens wear for keratoconus, phthisis bulbi, and myopathy due to Kearns-Sayre syndrome were identified during a 2-year period. They were fitted with scleral contact lenses in order to provide cosmesis by lifting the upper eyelid with the bulk of the lens, and simultaneously provide vision correction where applicable. The scleral contact lenses provided comfortable wear, significantly improved cosmesis as both palpebral aperture and marginal reflex distance were increased, and visual acuity was also subjectively and objectively improved. Two of the patients opted for the scleral contact lenses, whereas the parents of the third patient, a 10-year-old girl with Kearns-Sayre syndrome, chose to undergo ptosis surgery due to handling issues of the scleral contact lenses. Scleral contact lenses can be a useful addition to the treatment option for patients with complicated ptosis.

  16. Translating ocular biomechanics into clinical practice: current state and future prospects.

    PubMed

    Girard, Michaël J A; Dupps, William J; Baskaran, Mani; Scarcelli, Giuliano; Yun, Seok H; Quigley, Harry A; Sigal, Ian A; Strouthidis, Nicholas G

    2015-01-01

    Biomechanics is the study of the relationship between forces and function in living organisms and is thought to play a critical role in a significant number of ophthalmic disorders. This is not surprising, as the eye is a pressure vessel that requires a delicate balance of forces to maintain its homeostasis. Over the past few decades, basic science research in ophthalmology mostly confirmed that ocular biomechanics could explain in part the mechanisms involved in almost all major ophthalmic disorders such as optic nerve head neuropathies, angle closure, ametropia, presbyopia, cataract, corneal pathologies, retinal detachment and macular degeneration. Translational biomechanics in ophthalmology, however, is still in its infancy. It is believed that its use could make significant advances in diagnosis and treatment. Several translational biomechanics strategies are already emerging, such as corneal stiffening for the treatment of keratoconus, and more are likely to follow. This review aims to cultivate the idea that biomechanics plays a major role in ophthalmology and that the clinical translation, lead by collaborative teams of clinicians and biomedical engineers, will benefit our patients. Specifically, recent advances and future prospects in corneal, iris, trabecular meshwork, crystalline lens, scleral and lamina cribrosa biomechanics are discussed.

  17. Translating Ocular Biomechanics into Clinical Practice: Current State and Future Prospects

    PubMed Central

    Girard, Michaël J.A.; Dupps, William J.; Baskaran, Mani; Scarcelli, Giuliano; Yun, Seok H.; Quigley, Harry A.; Sigal, Ian A.; Strouthidis, Nicholas G.

    2014-01-01

    Biomechanics – the study of the relationship between forces and function in living organisms – is thought to play a critical role in a significant number of ophthalmic disorders. This is not surprising, as the eye is a pressure vessel that requires a delicate balance of forces to maintain its homeostasis. Over the past few decades, basic science research in ophthalmology mostly confirmed that ocular biomechanics could explain in part the mechanisms involved in almost all major ophthalmic disorders such as optic nerve head neuropathies, angle closure, ametropia, presbyopia, cataract, corneal pathologies, retinal detachment, and macular degeneration. Translational biomechanics in ophthalmology, however, is still in its infancy. It is believed that its use could make significant advances in diagnosis and treatment. Several translational biomechanics strategies are already emerging, such as corneal stiffening for the treatment of keratoconus, and more are likely to follow. This review aims to cultivate the idea that biomechanics plays a major role in ophthalmology and that its clinical translation, lead by collaborative teams of clinicians and biomedical engineers, will benefit our patients. Specifically, recent advances and future prospects in corneal, iris, trabecular meshwork, crystalline lens, scleral and lamina cribrosa biomechanics are discussed. PMID:24832392

  18. Cellular structure of the healthy and keratoconic human cornea imaged in-vivo with sub-micrometer axial resolution OCT(Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bizheva, Kostadinka; Tan, Bingyao; Mason, Erik; Carter, Kirsten; Haines, Lacey; Sorbara, Luigina

    2017-02-01

    Keratoconus causes progressive morphological changes in the corneal epithelium (EPI), Bowman's membrane (BM) and anterior stroma. However, it is still not well understood if KC originates in the corneal epithelium and propagates to the anterior stroma through disruptions of the BM, or vice versa. In this study we used a sub-micrometer axial resolution OCT system to image in-vivo the cellular structure of the EPI layer and the fibrous structure of the BM and the anterior stroma in mild to advanced keratoconics, as well as healthy subjects. The imaging study was approved by the University of Waterloo Human Research Ethics Committee. The OCT system operates in the 800 nm spectral region at 34 kHz image acquisition rate and provides 0.95 um axial and < 2 um lateral resolution in corneal tissue, which is sufficient to visualize the cellular structure of the corneal epithelium and the fibrous structure of the BM. In some subjects, localized thinning and thickening of the EPI layer was observed, while there was no visible damage to the BM or anterior stroma. In other subjects, localized breakage of the stromal collagen fibrils was observed with no significant morphological changes of the corneal EPI.

  19. Nonlinear optical collagen cross-linking and mechanical stiffening: a possible photodynamic therapeutic approach to treating corneal ectasia

    PubMed Central

    Chai, Dongyul; Juhasz, Tibor; Brown, Donald J.

    2013-01-01

    Abstract. In this study we test the hypothesis that nonlinear optical (NLO) multiphoton photoactivation of riboflavin using a focused femtosecond (FS) laser light can be used to induce cross-linking (CXL) and mechanically stiffen collagen as a potential clinical therapy for the treatment of keratoconus and corneal ectasia. Riboflavin-soaked, compressed collagen hydrogels are cross-linked using a FS laser tuned to 760 nm and set to either 100 mW (NLO CXL I) or 150 mW (NLO CXL II) of laser power. FS pulses are focused into the hydrogel using a 0.75 NA objective lens, and the hydrogel is three-dimensionally scanned. Measurement of hydrogel stiffness by indentation testing show that the calculated elastic modulus (E) values are significantly increased over twofold following NLO CXL I and II compared with baseline values (P<0.05). Additionally, no significant differences are detected between NLO CXL and single photon, UVA CXL (P>0.05). This data suggests that NLO CXL has a comparable effect to conventional UVA CXL in mechanically stiffening collagen and may provide a safe and effective approach to localize CXL at different regions and depths within the cornea. PMID:23515869

  20. Eye disorders associated with obstructive sleep apnoea.

    PubMed

    West, Sophie D; Turnbull, Chris

    2016-11-01

    Obstructive sleep apnoea (OSA) is increasing in prevalence due to rising obesity. Public awareness is also growing. Although OSA is a disorder primarily of the upper airway during sleep, its physiological impact on other parts of the body is now well recognized. There is increasing interest in the association of OSA with various eye disorders. Work in this field has been directed predominantly to OSA prevalence and association studies, but some authors have tried to elucidate the effect of OSA therapies on eye diseases, including continuous positive airway pressure, upper airway surgery or bariatric surgery. This review discusses the publications in this area from the past year. The key ocular disorders featured in the studies and meta-analayses include glaucoma, floppy eyelid syndrome, nonarteritic ischaemic optic neuropathy, keratoconus, age-related macular degeneration and diabetic retinopathy. Associations with OSA were found with all these conditions, but aspects of the studies still leave gaps in our knowledge. This review highlights the need for ophthalmologists to consider OSA in their patients and also makes recommendations for future research studies, especially whether therapies for OSA can be effective for ocular disorders also.

  1. Epidemiology of ametropia of U.S. Army recruits.

    PubMed

    McAlister, W H; Wingert, T A

    1995-02-01

    All people attempting to enlist in the U.S. Army must undergo a physical examination that requires a rudimentary vision screening. Those who pass the physical, upon reporting to basic training, are again evaluated and any treatment necessary to allow the recruits to function during their initial indoctrination is provided. Those who fail to see 20/20 O.D. and O.S. with their current spectacles fail the screening and are evaluated by an optometrist. If their condition is not disqualifying, appropriate correction is prescribed. We reviewed the records of all the recruits in a 1-month period who either required spectacles to see 20/20 or failed the screening at the 43rd AG BN (reception). Epidemiological evaluation revealed most to be either simple myopes or myopic astigmats. Hyperopia and hyperopic astigmatism accounted for the next most common diagnosis. Other conditions included anisometropia, antimetropia, amblyopia, keratoconus, and nystagmus. Examinations of these recruits were very limited, with dilated fundus evaluations being performed only when there was a high probability of a disqualifying condition. Therefore, it is unknown what retinal disease or degeneration may be present other than what would be visible with direct ophthalmoscopy.

  2. Clinical features of atopic keratoconjunctivitis.

    PubMed

    Tuft, S J; Kemeny, D M; Dart, J K; Buckley, R J

    1991-02-01

    The clinical spectrum of ocular disease in 37 patients with atopic keratoconjunctivitis (AKC) is described. Patients typically had a severe blepharoconjunctivitis. Associated corneal scarring, suppurative keratitis, or keratoconus were the major causes of visual loss. Serum and tear samples from these patients were analyzed to quantify total and specific IgE antibodies. The results were compared as a case control study with results from samples from 55 patients with other forms of atopic disease and 16 nonatopic volunteers. Although the mean values for total and specific IgEs in the serum of patients with atopic disease were markedly higher than the values from nonatopic controls (P less than 0.00002), a difference between the disease groups could not be demonstrated (P greater than 0.05). There were also differences between both the total IgE (P = 0.0002) and pollen-specific IgE (P = 0.015) in tears from patients with atopic disease and nonatopic controls, but not for house dust mite or cat dander-specific IgEs. These results suggest that clinical differences between groups of patients with chronic allergic external eye disease are not associated with specific patterns of IgE production.

  3. Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement.

    PubMed

    Penna, Rachele R; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M

    2017-01-01

    To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0

  4. Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement

    PubMed Central

    Penna, Rachele R.; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M.

    2017-01-01

    AIM To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0

  5. Status of children in blind schools in the northern areas of Pakistan.

    PubMed

    Kazmi, Hasan Sajid; Shah, Ashfaq Ali; Awan, Abdul Aziz; Khan, Jaffar; Siddiqui, Noman

    2007-01-01

    Prevalence of blindness in Pakistan is estimated to be 0.9%, which comes to about 1.25 million persons. A significant number of these are persons under 20 years of age. To make these children useful citizens in future, special facilities are to be provided to these children for their education and training. A study was done to find out the visual status of the students studying in a blind school in Abbottabad, Pakistan, the only such facility in the region. A total of 50 patients were examined during our visit to the blind school in Abbottabad. Age of the patients ranged from 6 to 27 years (mean: 12.32 years). All the students, who were otherwise healthy, were included in the study. The most common disorder identified was malformed globe or traumatic eyes (16 cases, 32%), in most of the cases, leading to phthisis bulbi. Other conditions noticed were Retinitis Pigmentosa (10 cases, 20%), Keratoconus, Optic atrophy, Buphthalmos (6 cases each, 12%), corneal opacity (4 cases, 8%) and retinal detachment (2 cases 4%). We should work towards betterment of these schools by providing them with more funds, equipment and manpower. Regular visits of Ophthalmologists to these schools may be helpful. Genetic counselling should be arranged for the families.

  6. Assessment of corneal hydration sensing in the terahertz band: in vivo results at 100 GHz

    PubMed Central

    Taylor, Zachary; Tewari, Pria; Sung, Shijun; Maccabi, Ashkan; Singh, Rahul; Culjat, Martin; Grundfest, Warren; Hubschman, Jean-Pierre; Brown, Elliott

    2012-01-01

    Abstract. Terahertz corneal hydration sensing has shown promise in ophthalmology applications and was recently shown to be capable of detecting water concentration changes of about two parts in a thousand in ex vivo corneal tissues. This technology may be effective in patient monitoring during refractive surgery and for early diagnosis and treatment monitoring in diseases of the cornea. In this work, Fuchs dystrophy, cornea transplant rejection, and keratoconus are discussed, and a hydration sensitivity of about one part in a hundred is predicted to be needed to successfully distinguish between diseased and healthy tissues in these applications. Stratified models of corneal tissue reflectivity are developed and validated using ex vivo spectroscopy of harvested porcine corneas that are hydrated using polyethylene glycol solutions. Simulation of the cornea’s depth-dependent hydration profile, from 0.01 to 100 THz, identifies a peak in intrinsic reflectivity contrast for sensing at 100 GHz. A 100 GHz hydration sensing system is evaluated alongside the current standard ultrasound pachymetry technique to measure corneal hydration in vivo in four rabbits. A hydration sensitivity, of three parts per thousand or better, was measured in all four rabbits under study. This work presents the first in vivo demonstration of remote corneal hydration sensing. PMID:23085925

  7. In Vivo Confocal Microscopy of Corneal Nerves in Health and Disease

    PubMed Central

    Cruzat, Andrea; Qazi, Yureeda; Hamrah, Pedram

    2016-01-01

    In vivo confocal microscopy (IVCM) is becoming an indispensable tool for studying corneal physiology and disease. Enabling the dissection of corneal architecture at a cellular level, this technique offers fast and noninvasive in vivo imaging of the cornea with images comparable to that of ex vivo histochemical techniques. Corneal nerves bear substantial relevance to clinicians and scientists alike, given their pivotal roles in regulation of corneal sensation, maintenance of epithelial integrity, and proliferation and promotion of wound healing. Thus, IVCM offers a unique method to study corneal nerve alterations in a myriad of conditions, such as ocular and systemic diseases and following corneal surgery, without altering the tissue microenvironment. Of particular interest has been the correlation of corneal subbasal nerves to their function, which has been studied in normal eyes, contact lens wearers, and patients with keratoconus, infectious keratitis, corneal dystrophies, and neurotrophic keratopathy. Longitudinal studies have applied IVCM to investigate the effects of corneal surgery on nerves, demonstrating their regenerative capacity. IVCM is increasingly important in the diagnosis and management of systemic conditions such as peripheral diabetic neuropathy and, more recently, in ocular diseases. In this review, we outline the principles and applications of IVCM in the study of corneal nerves in various ocular and systemic diseases. PMID:27771327

  8. Iridoplasty of fixed-dilated pupil (Urrets-Zavalia syndrome) after deep anterior lamellar keratoplasty

    PubMed Central

    Ntora, Efthalia; Ziakas, Nikolaos

    2017-01-01

    A 38-year-old woman with advanced keratoconus initially developed Urrets-Zavalia Syndrome (UZS) in the left eye after deep anterior lamellar keratoplasty. During the uneventful surgery, a 7-mm-wide pupil unresponsive to light was noticed. On the first postoperative day, intraocular pressure (IOP) was elevated up to 45 mmHg with shallow anterior chamber (AC). A peripheral iridotomy in 2 o’clock position was conducted and a fixed combination of brinzolamide 1% and timolol 0.5% was administered topically. In the subsequent postoperative period, IOP was successfully reduced, but the patient reported severe photophobia, glare, and decreased vision. Twelve months after surgery, her best-corrected visual acuity (BCVA) was 20/200, the fixed-dilated pupil persisted, iris was atrophic, and lens opacities were detected. She was submitted for phacoemulsification cataract surgery combined with iridoplasty using the closed chamber slipping suture technique. Three months after surgery, her BCVA was 20/25, pupil diameter remained stable at 4 mm, and glare symptoms were significantly reduced. A very adequate cosmetic outcome was also achieved. Iridoplasty in postkeratoplasty patient with unilateral UZS was effective in improving patient's visual function disability and restoring residual anisocoria. This technique can be applied as a single procedure or combined with another one for the management of UZS. PMID:29118500

  9. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology

    PubMed Central

    Ouchi, M; Kinoshita, S

    2015-01-01

    Purpose To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. Methods LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Results Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. Conclusion With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies. PMID:25744442

  10. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

    PubMed

    Ouchi, M; Kinoshita, S

    2015-05-01

    To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.

  11. High-resolution, label-free two-photon imaging of diseased human corneas

    NASA Astrophysics Data System (ADS)

    Batista, Ana; Breunig, Hans Georg; König, Aisada; Schindele, Andreas; Hager, Tobias; Seitz, Berthold; König, Karsten

    2018-03-01

    The diagnosis of corneal diseases may be improved by monitoring the metabolism of cells and the structural organization of the stroma using two-photon imaging (TPI). We used TPI to assess the differences between nonpathological (NP) human corneas and corneas diagnosed with either keratoconus, Acanthamoeba keratitis, or stromal corneal scars. Images were acquired using a custom-built five-dimensional laser-scanning microscope with a broadband sub-15 femtosecond near-infrared pulsed excitation laser and a 16-channel photomultiplier tube detector in combination with a time-correlated single photon counting module. Morphological alterations of epithelial cells were observed for all pathologies. Moreover, diseased corneas showed alterations to the cells' metabolism that were revealed using the NAD(P)H free to protein-bound ratios. The mean autofluorescence lifetime of the stroma and the organization of the collagen fibers were also significantly altered due to the pathologies. We demonstrate that TPI can be used to distinguish between NP and diseased human corneas, based not only on alterations of the cells' morphology, which can also be evaluated using current clinical devices, but on additional morphological and functional features such as the organization of the stroma and the cells' metabolism. Therefore, TPI could become an efficient tool for diagnosing corneal diseases and better understanding the biological processes of the diseases.

  12. Prevalence and risk factors of vision impairment among children of employees of Telecom, Italy.

    PubMed

    Nucci, Carlo; Cofini, Vincenza; Mancino, Raffaele; Ricci, Federico; Martucci, Alessio; Cecilia, Maria Rosita; Ciciarelli, Vincenzo; Zazzara, Francesca; Cedrone, Claudio; di Orio, Ferdinando

    2016-06-10

    To define the prevalence, causes, and risk factors of vision impairment (VI) in children. In this study, relatives of Association for Supplemental Health Insurance to the Employees of Telecom members aged 5-16 years were examined in all Italian regions. A standardized record card was used to collect data on medical history; keratometry; objective refraction; uncorrected, presenting, and best-corrected visual acuity (VA); examination of the pupils, adnexa, and anterior segment; direct ophthalmoscopy; posterior segment and fundus examination; and assessment for ocular pathology. Binocular and monocular VI were defined by a VA <5/10 (or <20/40). The campaign included 17,508 children, 12,798 of whom (73.1%) were examined (and 12,740 on whom all VA data were gathered). The prevalence of uncorrected, presenting, and best-corrected VI in the better eye was 9.0%, 2.51%, and 0.10%, respectively. The following variables were associated with presenting VI: age 10-16 years, family history of myopia, female sex, family history of keratoconus, and hypertension. Myopia is the main cause of VI (82.6%). A total of 96% of children with presenting VI had correctable VI. Correctable VI because of myopia is an important public health problem in school-age children in Italy.

  13. Assessment of corneal hydration sensing in the terahertz band: in vivo results at 100 GHz

    NASA Astrophysics Data System (ADS)

    Bennett, David; Taylor, Zachary; Tewari, Pria; Sung, Sijun; Maccabi, Ashkan; Singh, Rahul; Culjat, Martin; Grundfest, Warren; Hubschman, Jean-Pierre; Brown, Elliott

    2012-09-01

    Terahertz corneal hydration sensing has shown promise in ophthalmology applications and was recently shown to be capable of detecting water concentration changes of about two parts in a thousand in ex vivo corneal tissues. This technology may be effective in patient monitoring during refractive surgery and for early diagnosis and treatment monitoring in diseases of the cornea. In this work, Fuchs dystrophy, cornea transplant rejection, and keratoconus are discussed, and a hydration sensitivity of about one part in a hundred is predicted to be needed to successfully distinguish between diseased and healthy tissues in these applications. Stratified models of corneal tissue reflectivity are developed and validated using ex vivo spectroscopy of harvested porcine corneas that are hydrated using polyethylene glycol solutions. Simulation of the cornea's depth-dependent hydration profile, from 0.01 to 100 THz, identifies a peak in intrinsic reflectivity contrast for sensing at 100 GHz. A 100 GHz hydration sensing system is evaluated alongside the current standard ultrasound pachymetry technique to measure corneal hydration in vivo in four rabbits. A hydration sensitivity, of three parts per thousand or better, was measured in all four rabbits under study. This work presents the first in vivo demonstration of remote corneal hydration sensing.

  14. Adaptive cornea modeling from keratometric data.

    PubMed

    Martínez-Finkelshtein, Andrei; López, Darío Ramos; Castro, Gracia M; Alió, Jorge L

    2011-07-01

    To introduce an iterative, multiscale procedure that allows for better reconstruction of the shape of the anterior surface of the cornea from altimetric data collected by a corneal topographer. The report describes, first, an adaptive, multiscale mathematical algorithm for the parsimonious fit of the corneal surface data that adapts the number of functions used in the reconstruction to the conditions of each cornea. The method also implements a dynamic selection of the parameters and the management of noise. Then, several numerical experiments are performed, comparing it with the results obtained by the standard Zernike-based procedure. The numerical experiments showed that the algorithm exhibits steady exponential error decay, independent of the level of aberration of the cornea. The complexity of each anisotropic Gaussian-basis function in the functional representation is the same, but the parameters vary to fit the current scale. This scale is determined only by the residual errors and not by the number of the iteration. Finally, the position and clustering of the centers, as well as the size of the shape parameters, provides additional spatial information about the regions of higher irregularity. The methodology can be used for the real-time reconstruction of both altimetric data and corneal power maps from the data collected by keratoscopes, such as the Placido ring-based topographers, that will be decisive in early detection of corneal diseases such as keratoconus.

  15. [Internal astigmatism with other ocular lesions].

    PubMed

    Limaiem, R; Baba, A; Bouraoui, R; Mghaieth, F; El Matri, L

    2012-04-01

    Astigmatism is a refractive defect whose origin is not always purely corneal, and is sometimes the result of corneal, crystalline lens or mixte contributions. The aim of our study is to report, through two cases, ocular lesions associated with a lenticular astigmatism and their evolution after treatment. In the first observation, it is a 25-year-old patient with a unilateral extra corneal astigmatism within the framework of the "tilted disc syndrome" associated with bilateral myopia. This patient has received treatment by Lasik. The postoperative course was good with a decline of 5 ans. The second observation is that of a patient aged 35 years without having a general history with a posterior lenticonus associated with keratoconus responsible for a major mixed astigmatism. She received combined surgery: penetrating keratoplasty with lens extraction and implantation of an artificial lens. The evolution was good with good visual recovery. The balance of internal astigmatism must include the systematic achievement of a subjective and objective refraction under cycloplegia and corneal topography. The search for etiology is critical to screen for eye or general disease and guide the therapeutic strategy. Knowledge of the refractive power of the cornea and crystalline lens of astigmatism separately would be important for surgery refractive and crystalline lens surgery. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  16. Are the surgeons safe during UV-A radiation exposure in collagen cross-linking procedure?

    PubMed

    Shetty, Rashmi; Shetty, Rohit; Mahendradas, Padmamalini; Shetty, Bhujang K

    2012-02-01

    To quantify the effect of scattered UV-A radiation used in the collagen cross-linking (CXL) procedure and the amount of radiation reaching the surgeon and the surrounding area and to estimate the dampening effect by various protective devices. In this case series, 3 patients [aged 25-30 (±2.5) years] with keratoconus underwent a CXL procedure with UV-A light and riboflavin. Irradiance was measured using a spectrometer (Model USB2000; Ocean Optics, Inc) for various distances from the source, at various angles, and for different durations of radiation. The spectrometer was also used to measure the dampening effect produced by gown, latex gloves, and UV-protective glasses. Maximum UV-A radiation (1.4 × 10(-9) mW/cm(2)) was measured at 2 cm from the limbus, when the probe was held at a 45-degree angle to the floor. UV-A radiation reaching the surgeon's eye and the abdomen was 3.403 × 10(-11) and 2.36 × 10(-11) mW/cm(2), respectively. Gown, latex gloves, and UV-protective glasses showed dampening effects of 99.58%, 95.01%, and 99.73%, respectively. CXL appears to be a safe procedure with respect to UV-A radiation exposure to the surgeon. Further safety can be ensured by UV-protective devices.

  17. Improving the mechanical properties of collagen-based membranes using silk fibroin for corneal tissue engineering.

    PubMed

    Long, Kai; Liu, Yang; Li, Weichang; Wang, Lin; Liu, Sa; Wang, Yingjun; Wang, Zhichong; Ren, Li

    2015-03-01

    Although collagen with outstanding biocompatibility has promising application in corneal tissue engineering, the mechanical properties of collagen-based scaffolds, especially suture retention strength, must be further improved to satisfy the requirements of clinical applications. This article describes a toughness reinforced collagen-based membrane using silk fibroin. The collagen-silk fibroin membranes based on collagen [silk fibroin (w/w) ratios of 100:5, 100:10, and 100:20] were prepared by using silk fibroin and cross-linking by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide. These membranes were analyzed by scanning electron microscopy and their optical property, and NaCl and tryptophan diffusivity had been tested. The water content was found to be dependent on the content of silk fibroin, and CS10 membrane (loading 10 wt % of silk fibroin) performed the optimal mechanical properties. Also the suture experiments have proved CS10 has high suture retention strength, which can be sutured in rabbit eyes integrally. Moreover, the composite membrane proved good biocompatibility for the proliferation of human corneal epithelial cells in vitro. Lamellar keratoplasty shows that CS10 membrane promoted complete epithelialization in 35 ± 5 days, and their transparency is restored quickly in the first month. Corneal rejection reaction, neovascularization, and keratoconus are not observed. The composite films show potential for use in the field of corneal tissue engineering. © 2014 Wiley Periodicals, Inc.

  18. Induced videokeratography alterations in patients with excessive meibomian secretions.

    PubMed

    Markomanolakis, Marinos M; Kymionis, George D; Aslanides, Ioannis M; Astyrakakis, Nikolaos; Pallikaris, Ioannis G

    2005-01-01

    To describe lipid-induced specific videokeratographic (VKG) corneal changes and subsequent resolution after eyelid washing. VKG was performed with C-Scan corneal topography. In all patients an excessive meibomian gland lipid secretion was found with or without coexistent chronic posterior blepharitis. After the initial VKG, a meticulous cleaning of the lids with a mild alkali shampoo (10% Johnson's baby shampoo in sterile water) was done, first by gently scrubbing the closed eyelid fissure with the solution to mobilize and emulsify any Meibomian gland secretions followed by cleaning of the upper and lower margins individually, using Q-tip applicators soaked in the detergent. Three patients with tear film lipid layer excess (TFLE), which correlated with the presence of a superior or central corneal steepening in VKG, were studied. In two of the subjects, careful lid washing reversed either completely or partially this VKG effect, whereas in the last patient the VKG changes after artificially increasing the tear film lipid content is described. Meibomian gland lipid secretions may induce mainly superior and occasionally central VKG corneal steepening that is not correlated with any slit-lamp pathologic findings. Computerized corneal topography can help detect such corneal abnormalities, and their reversibility may distinguish them from other pathologic conditions (such as contact lens-induced warpage, eccentric ablations, irregular astigmatism, superior keratoconus).

  19. Reproducibility of the measurement of central corneal thickness in healthy subjects obtained with the optical low coherence reflectometry pachymeter and comparison with the ultrasonic pachymetry.

    PubMed

    Garza-Leon, Manuel; Plancarte-Lozano, Eduardo; Valle-Penella, Agustín Del; Guzmán-Martínez, María de Lourdes; Villarreal-González, Andrés

    2018-01-01

    Corneal pachymetry is widely used for refractive surgery and follow up in keratoconus, accurate measurement is essential for a safe surgery. To assess intraobserver reliability of central corneal thickness (CCT) measurements using optical low-coherence reflectometry (OLCR) technology and its agreement with ultrasonic pachymeter (US). Randomized and prospective comparative evaluation of diagnostic technology. One randomly healthy eye of subjects was scanned three times with both devices. Intraobserver within-subject standard deviation (Sw), coefficient of variation (CVw) and intraclass correlation coefficient (ICC) were obtained for reliability analysis; for study agreement, data were analyzed using the paired-sample t test and the Bland-Altman LoA method. The mean of three scans of each equipment was used to assess the LoA. The study enrolled 30 eyes of 30 subjects with average age of 28.70 ± 8.06 years. For repeatability, the Sw were 3.41 and 5.96 µ, the intraobserver CVw was 2 and 4% and ICC 0.991 and 0.988, for OLCR and US respectively. The mean CCT difference between OLCR and US was 8.90 ± 9.03 µ (95% confidence interval: 5.52-2.27 µ), and the LoA was 35.40 µ. OLCR technology provided reliable intraobserver CCT measurements. Both pachymetry measurements may be used interchangeably with minimum calibration adjustment. Copyright: © 2018 Permanyer.

  20. Variations in the endogenous fluorescence of rabbit corneas after mechanical property alterations

    NASA Astrophysics Data System (ADS)

    Ortega-Martinez, Antonio; Touchette, Genna; Zhu, Hong; Kochevar, Irene E.; Franco, Walfre

    2017-09-01

    Keratoconus is an eye disease in which the cornea progressively deforms due to loss of cornea mechanical rigidity, and thus causes deterioration of visual acuity. Techniques to characterize the mechanical characteristics of the cornea are important to better monitor changes and response to treatments. To investigate the feasibility of using the endogenous fluorescence of cornea for monitoring alterations of its mechanical rigidity, linear tensiometry was used to quantitate stiffness and Young's modulus (YM) after treatments that increase cornea stiffness (collagen photocross-linking) or decrease stiffness (enzymatic digestion). The endogenous ultraviolet fluorescence of cornea was also measured before and after these treatments. The fluorescence excitation/emission spectral ranges were 280 to 430/390 to 520 nm, respectively. A correlation analysis was carried out to identify fluorescence excitation/emission pairs whose intensity changes correlated with the stiffness. A positive correlation was found between variations in fluorescence intensity of the 415-/485-nm excitation/emission pair and YM of photocross-linked corneas. After treatment of corneas with pepsin, the YM decreased as the fluorescence intensity at 290-/390-nm wavelengths decreased. For weakening of corneas with collagenase, only qualitative changes in the fluorescence spectrum were observed. Changes in the concentration of native or newly created fluorescent molecular species contain information that may be directly or indirectly related to the mechanical structure of the cornea.

  1. Large (9 mm) Deep Anterior Lamellar Keratoplasty with Clearance of a 6-mm Optical Zone Optimizes Outcomes of Keratoconus Surgery.

    PubMed

    Busin, Massimo; Leon, Pia; Nahum, Yoav; Scorcia, Vincenzo

    2017-07-01

    To evaluate the outcomes of a 9-mm deep anterior lamellar keratoplasty (DALK) with removal of the deep stroma limited to the central 6-mm optical zone. Prospective, noncomparative, interventional case series. A total of 80 consecutive keratoconic eyes without deep stromal scarring, with at least 1 postoperative examination 1 month after complete suture removal. A standardized DALK was performed, including (1) deep trephination of the recipient bed 450 to 550 μm in depth and 9 mm in diameter; (2) pneumatic dissection; (3) debulking of approximately 80% of the anterior stroma; (4) removal of the deep stroma (bubble roof) from a central 6-mm optical zone; and (5) transplantation of a 9-mm anterior corneal lamella cut by microkeratome-assisted dissection (400-μm head) and sutured with a double running 10-0 nylon suture. Success rate and type of pneumatic dissection obtained; best spectacle-corrected visual acuity (BSCVA), refractive astigmatism (RA), and topographic astigmatism (TA), central corneal thickness (CCT) and endothelial cell density 12 months postoperatively; and intraoperative and postoperative complications. Pneumatic dissection created a "big bubble" in 67 of 80 eyes (83.7%), all of them but 1 (1.5%) being of type 1 according to the classification by Dua et al. After complete suture removal, BSCVA averaged 0.09±0.72 logarithm of the minimum angle of resolution (logMAR) and was ≥20/20 in 28 eyes (35%), ≥20/25 in 54 eyes (67.5%), and ≥20/40 in 76 eyes (95%); RA averaged 3.10±1.30 diopters (D), with 73 eyes (91%) within 4.5 D and none above 6 D; regular TA was detected in 72 eyes (90%); mean CCT was 492±62.10 μm; postoperative endothelial cell density averaged 2026±397cells/mm 2 with a mean cell loss of 11.2%. Intraoperative complications included loss of suction (n = 1) and perforation (n = 4). No conversion to penetrating keratoplasty was necessary. After surgery, double anterior chamber was observed in 2 cases (2.5%), both managed successfully by air filling of the anterior chamber. Stromal rejection was observed in 6 eyes (7.5%) and was reversed with topical steroids in all cases. In keratoconic eyes without deep stromal scars, the combination of a graft larger than conventional ones with limited removal of deep stroma can improve visual and refractive outcomes of DALK, while minimizing the rate of complications. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  2. Factors influencing flap and INTACS decentration after femtosecond laser application in normal and keratoconic eyes.

    PubMed

    Ertan, Aylin; Karacal, Humeyra

    2008-10-01

    To compare accuracy of LASIK flap and INTACS centration following femtosecond laser application in normal and keratoconic eyes. This is a retrospective case series comprising 133 eyes of 128 patients referred for refractive surgery. All eyes were divided into two groups according to preoperative diagnosis: group 1 (LASIK group) comprised 74 normal eyes of 72 patients undergoing LASIK with a femtosecond laser (IntraLase), and group 2 (INTACS group) consisted of 59 eyes of 39 patients with keratoconus for whom INTACS were implanted using a femtosecond laser (IntraLase). Decentration of the LASIK flap and INTACS was analyzed using Pentacam. Temporal decentration was 612.56 +/- 384.24 microm (range: 30 to 2120 microm) in the LASIK group and 788.33 +/- 500.34 microm (range: 30 to 2450 microm) in the INTACS group. A statistically significant difference was noted between the groups in terms of decentration (P < .05). Regression analysis showed that the amount of decentration of the LASIK flap and INTACS correlated with the central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group, respectively. Decentration with the IntraLase occurred in most cases, especially in keratoconic eyes. The applanation performed for centralization during IntraLase application may flatten and shift the pupil center, and thus cause decentralization of the LASIK flap and INTACS. Central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group proved to be statistically significant parameters associated with decentration.

  3. Decorin and biglycan of normal and pathologic human corneas

    NASA Technical Reports Server (NTRS)

    Funderburgh, J. L.; Hevelone, N. D.; Roth, M. R.; Funderburgh, M. L.; Rodrigues, M. R.; Nirankari, V. S.; Conrad, G. W.

    1998-01-01

    PURPOSE: Corneas with scars and certain chronic pathologic conditions contain highly sulfated dermatan sulfate, but little is known of the core proteins that carry these atypical glycosaminoglycans. In this study the proteoglycan proteins attached to dermatan sulfate in normal and pathologic human corneas were examined to identify primary genes involved in the pathobiology of corneal scarring. METHODS: Proteoglycans from human corneas with chronic edema, bullous keratopathy, and keratoconus and from normal corneas were analyzed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), quantitative immunoblotting, and immunohistology with peptide antibodies to decorin and biglycan. RESULTS: Proteoglycans from pathologic corneas exhibit increased size heterogeneity and binding of the cationic dye alcian blue compared with those in normal corneas. Decorin and biglycan extracted from normal and diseased corneas exhibited similar molecular size distribution patterns. In approximately half of the pathologic corneas, the level of biglycan was elevated an average of seven times above normal, and decorin was elevated approximately three times above normal. The increases were associated with highly charged molecular forms of decorin and biglycan, indicating modification of the proteins with dermatan sulfate chains of increased sulfation. Immunostaining of corneal sections showed an abnormal stromal localization of biglycan in pathologic corneas. CONCLUSIONS: The increased dermatan sulfate associated with chronic corneal pathologic conditions results from stromal accumulation of decorin and particularly of biglycan in the affected corneas. These proteins bear dermatan sulfate chains with increased sulfation compared with normal stromal proteoglycans.

  4. A novel mechanism of UV-A and riboflavin-mediated corneal cross-linking through induction of tissue transglutaminases.

    PubMed

    Kopsachilis, Nikolaos; Tsaousis, Konstantinos T; Tsinopoulos, Ioannis T; Kruse, Friedrich E; Welge-Luessen, Ulrich

    2013-07-01

    Collagen cross-linking using UV-A irradiation combined with the photosensitizer riboflavin is a new technique for treating progressive keratoconus. The purposes of this study were to examine whether primary human corneal keratocytes (HCKs) are capable of expressing and secreting fibronectin and tissue transglutaminase (tTgase), an enzyme cross-linking extracellular matrix protein, and to examine whether fibronectin and tTgase are increased after the treatment of HCK cells with UV-A irradiation combined with riboflavin (RFUV-A), thus providing another possible physiological mechanism of the cross-linking pathway. Cell cultures established from HCKs were treated with 0.025% riboflavin solution and UV-A (370 nm) irradiance 3 mW/cm2 for 30 minutes. Induction of fibronectin and tTgase was investigated by immunohistochemistry, real-time polymerase chain reaction, and Western blot analysis. Cell viability was quantified by a microscopic live-dead assay. External tTgase activity was measured by the ability to form polymerized fibronectin and the incorporation of biotinylated cadaverine into fibronectin. Treatment of cultured HCK cells with RFUV-A increased the fibronectin and tTgase messenger RNA and protein levels. This effect was not observed in cells treated with riboflavin or UV-A radiation alone. Incorporation of biotinylated cadaverine was significantly increased when HCK cells were treated with RFUV-A. The enzymes tTgase and fibronectin are expressed by RFUV-A treatment in cultured HCK cells. This mechanism provides more information about the physiology of corneal cross-linking.

  5. Changes in Corneal Density After Accelerated Corneal Collagen Cross-linking With Different Irradiation Intensities and Energy Exposures: 1-Year Follow-up.

    PubMed

    Akkaya Turhan, Semra; Toker, Ebru

    2017-11-01

    To determine and compare the changes in corneal density after 2 different protocols of accelerated corneal collagen cross-linking (A-CXL) in patients with progressive keratoconus. Two groups of eyes received A-CXL treatment; 20 eyes received A-CXL using continuous UVA light exposure at 9 mW/cm for 10 minutes with a total energy dose of 5.4 J/cm, and 24 eyes received A-CXL using continuous UVA light exposure at 30 mW/cm for 4 minutes with a total energy dose of 7.2 J/cm. Corneal density was measured with Scheimpflug tomography at 1, 3, 6, and 12 months of follow-up. Densitometry peaked at 1 month (mean: 16.34 ± 3.80, P = 0.006, 9-mW/cm A-CXL; mean: 20.90 ± 2.81, P < 0.0001, 30-mw/cm A-CXL) in both groups, and it decreased over time in 30-mW/cm A-CXL. However, in 9-mW/cm A-CXL, increased corneal densitometry plateaued until 6 months postoperatively and started to decrease thereafter. Densitometry completely returned to baseline after 12 months in both groups. The mean change in density at 1- and 3-month follow-up was higher in the 30-mW A-CXL group than in the 9-mW A-CXL group (P = 0.003, P = 0.044; respectively). High-energy exposure tends to induce more haze in the early posttreatment period, but it is reversible.

  6. Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

    PubMed

    Greenlee, Emily C; Kwon, Young H

    2008-06-01

    Glaucoma after penetrating keratoplasty is a frequently observed post-operative complication and is a risk factor for graft failure. Penetrating keratoplasty performed for aphakic and pseudophakic bullous keratopathy and inflammatory conditions are more likely to cause postoperative glaucoma compared with keratoconus and Fuchs' endothelial dystrophy. The intraocular pressure elevation may occur immediately after surgery or in the early to late postoperative period. Early postoperative causes of glaucoma include pre-existing glaucoma, retained viscoelastic, hyphema, inflammation, pupillary block, aqueous misdirection, or suprachoroidal hemorrhage. Late causes include pre-existing glaucoma, angle-closure glaucoma, ghost cell glaucoma, suprachoroidal hemorrhage, and steroid-induced glaucoma. Determining the cause of IOP elevation can help guide therapeutic intervention. Treatments for refractory glaucoma include topical anti-glaucoma medications such as beta-adrenergic blockers. Topical carbonic anhydrase inhibitors, miotic agents, adrenergic agonists, and prostaglandin analogs should be used with caution in the post-keratoplasty patient, because of the possibility of corneal decompensation, cystoid macular edema, or persistent inflammation. Various glaucoma surgical treatments have reported success in post-keratoplasty glaucoma. Trabeculectomy with mitomycin C can be successful in controlling IOP without the corneal toxicity noted with 5-fluorouracil. Glaucoma drainage devices have successfully controlled intraocular pressure in postkeratoplasty glaucoma; this is, however, associated with increased risk of graft failure. Placement of the tube through the pars plana may improve graft success compared with implantation within the anterior chamber. In addition, cyclophotocoagulation remains a useful procedure for eyes that have refractory glaucoma despite multiple surgical interventions.

  7. Validation of Fourier analysis of videokeratographic data.

    PubMed

    Sideroudi, Haris; Labiris, Georgios; Ditzel, Fienke; Tsaragli, Efi; Georgatzoglou, Kimonas; Siganos, Haralampos; Kozobolis, Vassilios

    2017-06-15

    The aim was to assess the repeatability of Fourier transfom analysis of videokeratographic data using Pentacam in normal (CG), keratoconic (KC) and post-CXL (CXL) corneas. This was a prospective, clinic-based, observational study. One randomly selected eye from all study participants was included in the analysis: 62 normal eyes (CG group), 33 keratoconus eyes (KC group), while 34 eyes, which had already received CXL treatment, formed the CXL group. Fourier analysis of keratometric data were obtained using Pentacam, by two different operators within each of two sessions. Precision, repeatability and Intraclass Correlation Coefficient (ICC), were calculated for evaluating intrassesion and intersession repeatability for the following parameters: Spherical Component (SphRmin, SphEcc), Maximum Decentration (Max Dec), Regular Astigmatism, and Irregularitiy (Irr). Bland-Altman analysis was used for assessing interobserver repeatability. All parameters were presented to be repeatable, reliable and reproductible in all groups. Best intrasession and intersession repeatability and reliability were detected for parameters SphRmin, SphEcc and Max Dec parameters for both operators using ICC (intrasession: ICC > 98%, intersession: ICC > 94.7%) and within subject standard deviation. Best precision and lowest range of agreement was found for the SphRmin parameter (CG: 0.05, KC: 0.16, and CXL: 0.2) in all groups, while the lowest repeatability, reliability and reproducibility was detected for the Irr parameter. The Pentacam system provides accurate measurements of Fourier tranform keratometric data. A single Pentacam scan will be sufficient for most clinical applications.

  8. The Evolution of Corneal Transplantation.

    PubMed

    Röck, Tobias; Landenberger, Johanna; Bramkamp, Matthias; Bartz-Schmidt, Karl Ulrich; Röck, Daniel

    2017-12-15

    BACKGROUND The aim of this study was to investigate the evolution of surgical methods in and leading indications for corneal transplantation from 2005 to 2016. MATERIAL AND METHODS Data from the corneal graft waiting list and from all keratoplasties carried out between 2005 and 2016 at the University Eye Hospital Tübingen were retrospectively evaluated. RESULTS A total of 1259 keratoplasties were performed between 2005 and 2016 at the University Eye Hospital Tübingen. The most common surgical indications for corneal transplantation were Fuchs endothelial corneal dystrophy (45.5%) and keratoconus (14.2%). The mean rate of corneal transplantations almost doubled from 71 keratoplasties per year in the first 6-year period to 139 keratoplasties per year in the second 6-year period (P=0.005). The number of penetrating keratoplasties remained similar. The number of Descemet membrane endothelial keratoplasties (DMEK) increased significantly from 2008 to 2016 (P<0.0001). One DMEK procedure was performed in 2008 (representing 1.4% of all transplantations), while 75 DMEK procedures were performed in 2016 (representing 60.5% of all transplantations) (P<0.0001). DMEK became the favored surgical method for endothelial disorders, exceeding penetrating keratoplasty in 2013. CONCLUSIONS Our study shows evolutionary changes in preferred corneal transplantation techniques and leading indications for keratoplasty from 2005 to 2016. Since its introduction a decade ago, DMEK is currently the golden standard in the management of corneal endothelial dysfunction.

  9. Fluorescence spectroscopy for non-invasive measurement of mechanical stiffness after photo-crosslinking of rabbit cornea

    NASA Astrophysics Data System (ADS)

    Williams, Maura; Lewis, William; Ortega-Martinez, Antonio; Franco, Walfre

    2017-02-01

    Background and Objectives: Keratoconus is a disease characterized by progressive steepening and thinning of the cornea, altering visual acuity and sometimes potentiating the need for corneal transplant if the disease progresses.1-3 Corneal crosslinking, a procedure that uses topical riboflavin and UV light to increase the stiffness of the cornea through the creation of collagen crosslinks was recently approved by the FDA for use in the U.S. The objective of the present study was to investigate whether endogenous collagen fluorescence changes following treatment can be correlated to alterations in the stiffness of the cornea, thereby guiding treatment parameters. Study Design and Results: 78 ex-vivo rabbit eyes divided into three groups: riboflavin solution plus UV irradiation, dextran solution plus UV irradiation, and riboflavin solution only. An additional group of eyes received no treatment. The epithelium was removed from each sample and topical riboflavin was applied. Eyes were irradiated with a 365 nm black ray UV lamp for various treatment times, ranging from half the clinical treatment time to three times the length. Mechanical testing was performed to determine the force/displacement relationship for the various treatment times. Fluorescence spectral changes following treatment corresponded with changes in stiffness. In particular, a decrease in the value of fluorescence intensity at 290/340 nm excitation/emission wavelengths corresponded to an increase in corneal stiffness following treatment. It may be possible to use fluorescence spectral changes of endogenous corneal crosslinks to evaluate mechanical stiffness changes non-invasively.

  10. Penetrating Keratoplasty at a Tertiary Referral Center in Ethiopia: Indications and Outcomes.

    PubMed

    Ayalew, Menen; Tilahun, Yonas; Holsclaw, Doug; Indaram, Maanasa; Stoller, Nicole E; Keenan, Jeremy D; Rose-Nussbaumer, Jennifer

    2017-06-01

    To describe the indications, visual acuity outcomes, and graft survival after penetrating keratoplasty (PKP) in Addis Ababa, Ethiopia. The medical records of patients who underwent PKP at Menelik II Hospital between September 2000 and September 2013 were retrospectively reviewed. The prespecified outcomes were graft survival, visual acuity, and complication rates. A total of 321 patients underwent PKP during the study period and were included in the analysis. Indications for surgery were trachoma or leukoma in 141 (44%), keratoconus in 45 (14%), corneal dystrophy in 46 (14%), pseudophakic or aphakic bullous keratopathy in 28 (9%), trauma in 27 (8%), previous graft failure in 18 (6%), active ulcer, burn, or perforation in 9 (3%), and others in 7 (2%). The graft survival rate was 80% overall at 2 years but varied considerably depending on the indication for surgery. Uncorrected visual acuity improved from baseline mean logarithm of the minimum angle of resolution 2.09 (SD 0.67) to mean logarithm of the minimum angle of resolution of 1.53 (SD 1.03) at 2 years. A number of factors affected the visual acuity outcomes. Patients were not routinely refracted, and only 18% (N = 60) of patients had access to corrective spectacles or contact lenses postoperatively. Complication rates were high with infectious keratitis being the most common. PKP is becoming a viable treatment for corneal opacity in developing countries. However, the high burden of disease and lack of corrective lenses remain significant obstacles to overcome.

  11. Quantified elasticity mapping of ocular tissue using acoustic radiation force optical coherence elastography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Qu, Yueqiao; He, Youmin; Zhang, Yi; Ma, Teng; Zhu, Jiang; Miao, Yusi; Dai, Cuixia; Silverman, Ronald; Humayun, Mark S.; Zhou, Qifa; Chen, Zhongping

    2017-02-01

    Age-related macular degeneration and keratoconus are two ocular diseases occurring in the posterior and anterior eye, respectively. In both conditions, the mechanical elasticity of the respective tissues changes during the early onset of disease. It is necessary to detect these differences and treat the diseases in their early stages to provide proper treatment. Acoustic radiation force optical coherence elastography is a method of elasticity mapping using confocal ultrasound waves for excitation and Doppler optical coherence tomography for detection. We report on an ARF-OCE system that uses modulated compression wave based excitation signals, and detects the spatial and frequency responses of the tissue. First, all components of the system is synchronized and triggered such that the signal is consistent between frames. Next, phantom studies are performed to validate and calibrate the relationship between the resonance frequency and the Young's modulus. Then the frequency responses of the anterior and posterior eye are detected for porcine and rabbit eyes, and the results correlated to the elasticity. Finally, spatial elastograms are obtained for a porcine retina. Layer segmentation and analysis is performed and correlated to the histology of the retina, where five distinct layers are recognized. The elasticities of the tissue layers will be quantified according to the mean thickness and displacement response for the locations on the retina. This study is a stepping stone to future in-vivo animal studies, where the elastic modulus of the ocular tissue can be quantified and mapped out accordingly.

  12. Non-Orthogonal Corneal Astigmatism among Normal and Keratoconic Brazilian and Chinese populations.

    PubMed

    Abass, Ahmed; Clamp, John; Bao, FangJun; Ambrósio, Renato; Elsheikh, Ahmed

    2018-06-01

    To investigate the prevalence of non-orthogonal astigmatism among normal and keratoconic Brazilian and Chinese populations. Topography data were obtained using the Pentacam High Resolution (HR) system ® from 458 Brazilian (aged 35.6 ± 15.8 years) and 505 Chinese (aged 31.6 ± 10.8 years) eyes with no history of keratoconus or refractive surgery, and 314 Brazilian (aged 24.2 ± 5.7 years) and 74 Chinese (aged 22.0 ± 5.5 years) keratoconic eyes. Orthogonal values of optical flat and steep powers were determined by finding the angular positions of two perpendicular meridians that gave the maximum difference in power. Additionally, the angular positions of the meridians with the minimum and maximum optical powers were located while being unrestricted by the usual orthogonality assumption. Eyes were determined to have non-orthogonal astigmatism if the angle between the two meridians with maximum and minimum optical power deviated by more than 5° from 90°. Evidence of non-orthogonal astigmatism was found in 39% of the Brazilian keratoconic eyes, 26% of the Chinese keratoconic eyes, 29% of the Brazilian normal eyes and 20% of the Chinese normal eyes. The large percentage of participants with non-orthogonal astigmatism in both normal and keratoconic eyes illustrates the need for the common orthogonality assumption to be reviewed when correcting for astigmatism. The prevalence of non-orthogonality should be considered by expanding the prescription system to consider the two power meridians and their independent positions.

  13. Phototoxic Effect of Topical Fluoroquinolones Administered Before Corneal Crosslinking in a Murine Model.

    PubMed

    Reviglio, Victor E; Osaba, Matias; Sambuelli, Gabriela; Kuo, Irene C

    2017-03-01

    Corneal crosslinking by UV light (UV-CXL) has become a popular treatment for keratoconus and corneal ectasia. Fluoroquinolones (FQs), commonly administered topically before UV-CXL, are known to be phototoxic to the skin and lens. The purpose of this study was to investigate phototoxic effects of topical FQ treatment on murine corneas before UV-CXL, in which the corneal epithelium was kept intact. Murine corneas were treated with various antibiotics with or without riboflavin before UV-CXL. At 24 h, the animals were sacrificed, and the corneas were analyzed for histologic evidence of inflammation and apoptosis and for expression of apoptosis markers BAX and caspases 3 and 9 and for expression of matrix metalloproteinase 9 (MMP-9). Spectrofluorometric analysis was performed. Corneas treated with topical FQ with or without riboflavin before UV-CXL showed mild corneal stromal inflammation, apoptosis by both terminal deoxynucleotidyl transferase dUTP nick end labeling staining and increased expression of BAX gene and caspases 3 and 9 by densitometric analysis. Untreated corneas, corneas treated with azithromycin before UV-CXL, and corneas undergoing UV-CXL without any antibiotic or riboflavin pretreatment showed normal histology, no staining for apoptosis, and no increased production of apoptosis markers by polymerase chain reaction. The phototoxic effects of FQs on the cornea may lead surgeons to consider another antibiotic class for prophylaxis against infectious keratitis in UV-CXL. These effects, along with the known cytotoxic effects of FQs independent of UV radiation, may contribute to some of the complications of corneal UV-CXL. Dosage studies may be warranted.

  14. Evaluation of corneal changes after conventional versus accelerated corneal cross-linking: a randomized controlled trial.

    PubMed

    Hashemian, Hesam; Jabbarvand, Mahmoud; Khodaparast, Mehdi; Ameli, Kambiz

    2014-12-01

    To evaluate the outcome of accelerated and conventional corneal cross-linking (CXL) procedures regarding their effect on morphological and optical properties of the cornea. One hundred fifty-three eyes of 153 patients were evaluated before and during a 15-month follow-up period after CXL (76 eyes in the conventional group and 77 eyes in the accelerated group). Measured variables include corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), refraction, maximum keratometry, endothelial cell density, anterior and posterior stromal keratocyte density, and subbasal nerve density. All variables were compared between the two study groups. Cylindrical and spherical components of refraction improved significantly during 15 months of follow-up. No difference was observed between the two study groups. UDVA and CDVA improved in the same manner, with no intergroup differences. Endothelial cell density did not change significantly during the follow-up period in either group. K-max increased slightly in the first month of the follow-up, but started to decrease at postoperative visits without any significant difference in the two groups. Anterior stromal keratocyte density and subbasal nerve density decreased significantly in both groups 1 month postoperatively. Both variables had a more significant decrease in the conventional group at all visits before the 1-year visit. At the final 15-month visit, there were no significant differences in any value between the two groups. Accelerated and conventional CXL seem to have a comparable and acceptable effect on keratoconus in the short-term follow-up period. Copyright 2014, SLACK Incorporated.

  15. Can Appropriate Systemic Treatment Help Protect the Cornea in Patients With Rheumatoid Arthritis? A Multidisciplinary Approach to Autoimmune Ocular Involvement.

    PubMed

    Amador-Patarroyo, Manuel J; Jalil-Florencia, Emilio; Otero-Marquez, Oscar; Molano-Gonzalez, Nicolás; Mantilla, Ruben D; Rojas-Villarraga, Adriana; Anaya, Juan-Manuel; Barraquer-Coll, Carmen

    2018-02-01

    To correlate rheumatologic with ophthalmic and laboratory findings in patients with rheumatoid arthritis (RA) to identify what effect these have on development of ocular disease. This is a cross-sectional study of 172 eyes of 86 patients with RA. Patients were examined by a group of rheumatologists. Sociodemographic, clinical, and laboratory data were collected. All patients underwent complete ophthalmologic examination including corneal topography and endothelial cell count. There was no significant correlation between RA-negative prognostic indicators (NPIs) and pathologic corneal findings. Patients using disease-modifying antirheumatic drugs (DMARDs) and antimalarial drugs had greater corneal volumes (mean difference 8.51 mm, 90% confidence interval [CI], 3.98-13.04, P = 0.004; and 2.24, 90% CI, 0.32-4.54, P = 0.048, respectively). Patients using azathioprine had lower endothelial cell counts compared with those using other drugs (mean difference 180 cells/mm, 90% CI, 69-291, P = 0.008). Patients using biologic DMARDs had better tear osmolarity values (between 280 and 300 mOsm/L) than patients not using them (mean difference 14.3 mOsm/L, P = 0.022). There was no correlation between NPIs of RA and positive keratoconus screening indices (Spearman correlation OD -0.013, P = 0.91; OS -0.033, P = 0.76). There was no clear correlation between RA-NPIs and pathologic corneal findings in our study. DMARDs treatment may help maintain corneal integrity in our patients and prevented collagenolytic manifestations of RA. Other medications such as azathioprine should be used carefully, as endothelial damage may potentially occur.

  16. Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes

    PubMed Central

    Çınar, Yasin; Cingü, Abdullah Kürşat; Şahin, Muhammed; Yüksel, Harun; Türkcü, Fatih Mehmet; Çınar, Tuba; Çaça, İhsan

    2013-01-01

    Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were obtained using the Lenstar and US biometer to determine the reproducibility of the measurements between the two devices in keratoconic eyes. The Bland-Altman method was used to describe the agreement between the two devices. Results. The Lenstar could not measure at least one of the biometric properties in one eye and did not automatically give the corrected ACD in 2/3 of our study population. The Lenstar measured CCT (average difference 5.4 ± 19.6 µm; ICC = 0.90; P < 0.001), LT (average difference 0.13 ± 0.17 mm; ICC = 0.67; P < 0.001), and AL (average difference 0.10 ± 0.76 mm; ICC = 0.75; P < 0.001) thinner than US biometer, whereas it measured ACD (average difference 0.18 ± 0.17 mm; ICC = 0.85; P < 0.001) deeper than US biometer in keratoconic eyes. Conclusion. Although the difference between the measurements obtained using the two devices might be clinically acceptable, US biometry and Lenstar should not be used interchangeably for biometric measurements in KC patients. PMID:23986865

  17. Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes.

    PubMed

    Cınar, Yasin; Cingü, Abdullah Kürşat; Sahin, Muhammed; Sahin, Alparslan; Yüksel, Harun; Türkcü, Fatih Mehmet; Cınar, Tuba; Caça, Ihsan

    2013-01-01

    Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were obtained using the Lenstar and US biometer to determine the reproducibility of the measurements between the two devices in keratoconic eyes. The Bland-Altman method was used to describe the agreement between the two devices. Results. The Lenstar could not measure at least one of the biometric properties in one eye and did not automatically give the corrected ACD in 2/3 of our study population. The Lenstar measured CCT (average difference 5.4 ± 19.6 µm; ICC = 0.90; P < 0.001), LT (average difference 0.13 ± 0.17 mm; ICC = 0.67; P < 0.001), and AL (average difference 0.10 ± 0.76 mm; ICC = 0.75; P < 0.001) thinner than US biometer, whereas it measured ACD (average difference 0.18 ± 0.17 mm; ICC = 0.85; P < 0.001) deeper than US biometer in keratoconic eyes. Conclusion. Although the difference between the measurements obtained using the two devices might be clinically acceptable, US biometry and Lenstar should not be used interchangeably for biometric measurements in KC patients.

  18. Big-bubble deep anterior lamellar keratoplasty using central vs peripheral air injection: a clinical trial.

    PubMed

    Feizi, Sepehr; Daryabari, Seyed-Hashem; Najdi, Danial; Javadi, Mohammad Ali; Karimian, Farid

    2016-06-10

    To compare 2 sites of air injection to achieve Descemet membrane (DM) detachment in big-bubble deep anterior lamellar keratoplasty (DALK). In this prospective, randomized study, 48 eyes of 48 keratoconus-affected patients who underwent DALK by cornea fellows were enrolled. Each patient was randomly assigned into one of 2 groups. After trephination to approximately 80% of the corneal thickness, a 27-G needle was inserted into the stroma from the trephination site. The needle was moved radially inside the trephination site and advanced to the central or paracentral cornea in group 1. In group 2, the needle was inserted into the deep stroma from the trephination site and advanced into the peripheral cornea to approximately 1.5 mm anterior to the limbus. Air was gently injected into the deep stroma until a big bubble was formed. The rates of DM separation and complications were compared between the 2 groups. Big-bubble formation was successful in 79.2% of the eyes in the study group. A bare DM was achieved by central injection in 68.0% of group 1 and by peripheral injection in 69.6% of group 2 (p = 0.68). This rate was increased to 80.0% and 78.3% in groups 1 and 2, respectively, after the injection site was shifted when injections failed. The study groups were comparable in terms of complications including DM perforation and bubble bursting. Both injection sites were equivalent in their rates of big-bubble formation and complications. Less experienced surgeons are advised to initially inject air outside the trephination.

  19. Laboratory measurement of the absorption coefficient of riboflavin for ultraviolet light (365 nm).

    PubMed

    Iseli, Hans Peter; Popp, Max; Seiler, Theo; Spoerl, Eberhard; Mrochen, Michael

    2011-03-01

    Corneal cross-linking (CXL) is an increasingly used treatment technique for stabilizing the cornea in keratoconus. Cross-linking (polymerization) between collagen fibrils is induced by riboflavin (vitamin B2) and ultraviolet light (365 nm). Although reported to reach a constant value at higher riboflavin concentrations, the Lambert-Beer law predicts a linear increase in the absorption coefficient. This work was carried out to determine absorption behavior at different riboflavin concentrations and to further investigate the purported plateau absorption coefficient value of riboflavin and to identify possible bleaching effects. The Lambert-Beer law was used to calculate the absorption coefficient at various riboflavin concentrations. The following investigated concentrations of riboflavin solutions were prepared using a mixture of 0.5% riboflavin and 20% Dextran T500 dissolved in 0.9% sodium chloride solution: 0%, 0.02%, 0.03%, 0.04%, 0.05%, 0.06%, 0.08%, 0.1%, 0.2%, 0.3%, 0.4%, and 0.5%, and were investigated with and without aperture plate implementation. An additional test series measured the transmitted power at selected riboflavin concentrations over time. In diluted solutions, a linear correlation exists between the absorption coefficient and riboflavin concentration. The absorption coefficient reaches a plateau, but this occurs at a higher riboflavin concentration (0.1%) than previously reported (just above 0.04%). Transmitted light power increases over time, indicating a bleaching effect of riboflavin. The riboflavin concentration can be effectively varied as a treatment parameter in a considerably broader range than previously thought. Copyright 2011, SLACK Incorporated.

  20. Prevention and treatment of corneal graft rejection: current practice patterns of the Cornea Society (2011).

    PubMed

    Kharod-Dholakia, Bhairavi; Randleman, J Bradley; Bromley, Jennifer G; Stulting, R Doyle

    2015-06-01

    To analyze current practice patterns in the prevention and treatment of corneal graft rejection for both penetrating keratoplasty (PK) and endothelial keratoplasty (EK) and to compare these patterns with previously reported practices. In 2011, an electronic survey was sent to 670 members of the Cornea Society worldwide addressing the routine postoperative management of corneal transplants at different time points, treatment of various manifestations of corneal graft rejection, and preferred surgical techniques. A total of 204 of 670 surveys (30%) were returned and evaluated. All respondents used topical corticosteroids for routine postoperative management and treatment of endothelial graft rejection. Prednisolone was the topical steroid of choice in all clinical scenarios, similar to previous surveys from 1989 to 2004. Use of subconjunctival and systemic steroids increased for many scenarios of probable and definite graft rejection. Routine use of prednisolone decreased by approximately 10% from previous surveys, whereas difluprednate was used in 13% of high-risk eyes during the first 6 months. Dexamethasone, fluorometholone, and loteprednol use remained stable. Adjunctive topical cyclosporine use increased significantly for PK and EK. EK was the preferred technique for endothelial dysfunction, whereas PK and deep anterior lamellar keratoplasty were both used for keratoconus and anterior scars. Most respondents (75%) felt that graft rejection occurs more frequently after PK than after EK. Prednisolone remains the treatment of choice for management and treatment of graft rejection; however, since the introduction of difluprednate, its use has declined slightly since the introduction of difluprednate. Despite perceived differences in rejection rates, there were no differences in prophylactic steroid treatment for PK and EK.

  1. Influence of glucocorticosteroids on the biomechanical properties of in-vivo rabbit cornea.

    PubMed

    Yu, Ji-guo; Bao, Fang-jun; Joda, Akram; Fu, Xun-an; Zhou, Shi; Wang, Jing; Hu, Xiu-li; Wang, Qin-mei; Elsheikh, Ahmed

    2014-01-01

    Understanding corneal biomechanical responses during long-term glucocorticosteroids administration is important in clinical practice. The purpose of this study is to investigate the biomechanical influence of fluorometholone 0.1% eye drops on rabbit cornea. Thirty-eight Japanese white rabbits were randomly divided into three groups; a fluorometholone group, a supernatant group and a blank control group. For each rabbit in fluorometholone group, one cornea was treated with fluorometholone 0.1% eye drops four times a day for 8 weeks, while corneas of rabbits in supernatant group were treated in the same frequency with supernatant fraction centrifuged from fluorometholone 0.1% eye drops. The rabbits in the blank control group were not given any treatment. At the end of the 8 week observation period, the rabbits were euthanized and the eyes immediately enucleated and prepared for inflation testing. The experimental pressure-deformation data was used to derive the stress-strain behavior of each eye using an inverse modeling procedure. Comparisons of mechanical stiffness of corneas were conducted among the three groups to determine the influence of fluorometholone. The results showed that corneal stiffness decreased as the fluorometholone administration time prolonged. Comparisons of tangent modulus indicated average stiffness reductions of 34.2% and 33.5% in the fluorometholone group compared to the supernatant and control groups, respectively, at the end of the observation period. The stiffness-reduction effect of fluorometholone on the cornea should be considered in clinical management, especially when administrating it to biomechanically weakened corneas, such as after refractive surgeries and in cases of keratoconus. © 2013 Published by Elsevier Ltd.

  2. Central Corneal Thickness Increase Due to Stromal Thickening With Diabetic Peripheral Neuropathy Severity.

    PubMed

    Kumar, Navasuja; Pop-Busui, Rodica; Musch, David C; Reed, David M; Momont, Anna C; Hussain, Munira; Raval, Nilesh; Moroi, Sayoko E; Shtein, Roni

    2018-06-19

    To investigate the relationship between central corneal thickness (CCT) and diabetes disease severity among patients with diabetic peripheral neuropathy (DPN) compared with controls. In this cross-sectional study, 34 participants were examined. DPN status was assessed by clinical examination, nerve conduction studies, and quantitative sensory testing. All participants underwent comprehensive eye examination that included intraocular pressure measured by Goldmann applanation tonometry. CCT was measured by ultrasound pachymetry, and the thickness of corneal layers was assessed by corneal confocal microscopy. Association of CCT and DPN was examined using ANOVA. Among the 34 participants, there were 9 controls, 16 patients with mild DPN, and 9 patients with severe DPN. CCT was significantly increased in the DPN groups compared with controls (P = 0.0003). Mean CCT among controls was 552.7 ± 29.2 μm compared with 583.4 ± 25.0 μm in the mild DPN group and 613.3 ± 28.8 μm in the severe DPN group. In addition, stromal thickness differed significantly between the 3 study groups (P = 0.045). Mean stromal thickness among controls was 439.5 ± 23.5 μm compared with 478.9 ± 37.5 μm in the mild DPN group and 494.5 ± 39.1 μm in the severe DPN group. This study demonstrates that CCT increases with DPN severity because of an increase in stromal thickness. CCT increase associated with DPN has important clinical implications including glaucoma progression, keratoconus susceptibility, and intraocular pressure assessment and should be accounted for when evaluating patients with diabetes.

  3. The Big-Bubble Full Femtosecond Laser-Assisted Technique in Deep Anterior Lamellar Keratoplasty.

    PubMed

    Buzzonetti, Luca; Petrocelli, Gianni; Valente, Paola; Iarossi, Giancarlo; Ardia, Roberta; Petroni, Sergio; Parrilla, Rosa

    2015-12-01

    To describe the big-bubble full femtosecond laser-assisted (BBFF) technique, which could be helpful in standardizing the big-bubble technique in deep anterior lamellar keratoplasty (DALK). Ten eyes of 10 consecutive patients affected by keratoconus underwent the BBFF technique using the 150-kHz IntraLase femtosecond laser (Intra-Lase FS Laser; Abbott Medical Optics, Inc., Santa Ana, CA). A 9-mm diameter metal mask with a single fissure 0.7 mm wide oriented at the 12-o'clock position was positioned into the cone, over the laser glass. The laser performed a ring lamellar cut (internal diameter = 3 mm; external diameter = 8 mm) 100 µm above the thinnest point, with the photodisruption effectively occurring only in the corneal stroma corresponding to the fissure to create a deep stromal channel; subsequently, an anterior side cut created an arcuate incision, from the corneal surface to the deep stromal channel on the mask's opening site. The mask was removed and the laser performed a full lamellar cut 200 µm above the thinnest point to create a lamella. After the removal of the lamella, the air needle was inserted into the stromal channel and air was injected to achieve a big bubble. The big bubble was achieved in 9 eyes (all type 1 bubbles) and all procedures were completed as DALK. Preliminary results suggest that the BBFF technique could help in standardizing the big-bubble technique in DALK, reducing the "learning curve" for surgeons who approach this technique and the risks of intraoperative complications. Copyright 2015, SLACK Incorporated.

  4. Method for Expressing Clinical and Statistical Significance of Ocular and Corneal Wavefront Error Aberrations

    PubMed Central

    Smolek, Michael K.

    2011-01-01

    Purpose The significance of ocular or corneal aberrations may be subject to misinterpretation whenever eyes with different pupil sizes or the application of different Zernike expansion orders are compared. A method is shown that uses simple mathematical interpolation techniques based on normal data to rapidly determine the clinical significance of aberrations, without concern for pupil and expansion order. Methods Corneal topography (Tomey, Inc.; Nagoya, Japan) from 30 normal corneas was collected and the corneal wavefront error analyzed by Zernike polynomial decomposition into specific aberration types for pupil diameters of 3, 5, 7, and 10 mm and Zernike expansion orders of 6, 8, 10 and 12. Using this 4×4 matrix of pupil sizes and fitting orders, best-fitting 3-dimensional functions were determined for the mean and standard deviation of the RMS error for specific aberrations. The functions were encoded into software to determine the significance of data acquired from non-normal cases. Results The best-fitting functions for 6 types of aberrations were determined: defocus, astigmatism, prism, coma, spherical aberration, and all higher-order aberrations. A clinical screening method of color-coding the significance of aberrations in normal, postoperative LASIK, and keratoconus cases having different pupil sizes and different expansion orders is demonstrated. Conclusions A method to calibrate wavefront aberrometry devices by using a standard sample of normal cases was devised. This method could be potentially useful in clinical studies involving patients with uncontrolled pupil sizes or in studies that compare data from aberrometers that use different Zernike fitting-order algorithms. PMID:22157570

  5. Comparison of parametric methods for modeling corneal surfaces

    NASA Astrophysics Data System (ADS)

    Bouazizi, Hala; Brunette, Isabelle; Meunier, Jean

    2017-02-01

    Corneal topography is a medical imaging technique to get the 3D shape of the cornea as a set of 3D points of its anterior and posterior surfaces. From these data, topographic maps can be derived to assist the ophthalmologist in the diagnosis of disorders. In this paper, we compare three different mathematical parametric representations of the corneal surfaces leastsquares fitted to the data provided by corneal topography. The parameters obtained from these models reduce the dimensionality of the data from several thousand 3D points to only a few parameters and could eventually be useful for diagnosis, biometry, implant design etc. The first representation is based on Zernike polynomials that are commonly used in optics. A variant of these polynomials, named Bhatia-Wolf will also be investigated. These two sets of polynomials are defined over a circular domain which is convenient to model the elevation (height) of the corneal surface. The third representation uses Spherical Harmonics that are particularly well suited for nearly-spherical object modeling, which is the case for cornea. We compared the three methods using the following three criteria: the root-mean-square error (RMSE), the number of parameters and the visual accuracy of the reconstructed topographic maps. A large dataset of more than 2000 corneal topographies was used. Our results showed that Spherical Harmonics were superior with a RMSE mean lower than 2.5 microns with 36 coefficients (order 5) for normal corneas and lower than 5 microns for two diseases affecting the corneal shapes: keratoconus and Fuchs' dystrophy.

  6. Trends in the distribution of donor corneal tissue and indications for corneal transplantation: the New Zealand National Eye Bank Study 2000-2009.

    PubMed

    Cunningham, William J; Brookes, Nigel H; Twohill, Helen C; Moffatt, S Louise; Pendergrast, David G C; Stewart, Joanna M; McGhee, Charles N J

    2012-03-01

    To investigate the indications for corneal transplantation and the distribution of donor corneal tissue in New Zealand. Analysis of the prospective database of the New Zealand National Eye Bank. A total of 2205 corneal transplants were assessed. New Zealand National Eye Bank records were analysed for the decade 2000-2009. Variables analysed included donor corneal tissue distribution (including public and private sectors), indications for transplantation, donor corneal tissue recipient demographics (age and gender) and corneal transplantation type. An average of 220 corneal transplants were performed each year over the 10-year period (n=2205). The median recipient age was 45years (range 3 to 102years) and 54.0% of recipients were male. In total 71.8% of transplants were performed in the public health sector. Surgeons in the Auckland metropolitan area performed 47.2% of all corneal transplants. The most common indications for corneal transplantation were: keratoconus (41.1%), repeat transplant (17.0%), aphakic/pseudophakic bullous keratopathy (13.9%), corneal dystrophy (10.7%), keratitis (7.9%) and trauma (3.7%). Overall, penetrating keratoplasty accounted for 90.7% of all corneal transplants, however, during the latter half of the study there was a progressive shift in transplantation type, with deep anterior lamellar keratoplasty and Descemet's stripping endothelial keratoplasty combined accounting for 32.3% of all transplants in the final year of the study period. This New Zealand National Eye Bank study provides valuable data regarding the indications for corneal transplantation, transplant recipient demographics and changes in transplantation type in New Zealand over the past decade. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  7. Prevalence and causes of blindness and visual impairment among school children in south-western Nigeria.

    PubMed

    Ajaiyeoba, A I; Isawumi, M A; Adeoye, A O; Oluleye, T S

    2005-01-01

    The aim of the study was to assess the prevalence and identify the causes of blindness and visual impairment in school children of Ilesa-East Local Government Area of Osun State, Nigeria. A total of 1144 school children in primary and secondary schools were selected using a 2-stage random sampling method and examined to determine the prevalence and causes of blindness and visual impairment. A total of 17 (1.48%) children were blind or visually impaired. These comprised of 11 (0.96%) children who were visually impaired and 4 (0.3%) who were severely visually impaired. Only 2 (0.15%) school children were blind. The causes of visual impairment were refractive error 10 (0.87%) and immature cataract 1 (0.08%), causes of severe visual impairment included corneal opacities 2 (0.2%), amblyopia leading to squint 1 (0.08%) and 1 cataract 1 (0.08%). The causes of blindness in school children were corneal scars presumed to be due to vitamin A deficiency 1 (0.08%) and keratoconus 1 (0.08%). Causes of blindness and visual impairment in children attending regular schools in Nigeria were treatable. Prevention, early recognition and prompt treatment of these diseases by regular screening of school children would definitely reduce unnecessary visual handicap in Nigerian school children so that they can attain their full potential in the course of their education. Also, information from this study is relevant for the purpose of planning eye care programmes for the prevention of blindness in Nigerian school children. This will go a long way in the prevention of unnecessary blindness and visual impairment in school children.

  8. Ultra-high speed OCT allows measurement of intraocular pressure, corneal geometry, and corneal stiffness using a single instrument

    NASA Astrophysics Data System (ADS)

    Singh, Manmohan; Han, Zhaolong; Nair, Achuth; Schill, Alexander; Twa, Michael D.; Larin, Kirill V.

    2018-02-01

    Screening for ocular diseases, such as glaucoma and keratoconus, includes measuring the eye-globe intraocular pressure (IOP) and corneal biomechanical properties. However, currently available clinical tools cannot quantify corneal tissue material parameters, which can provide critical information for detecting diseases and evaluating therapeutic outcomes. Here, we demonstrate measurement of eye-globe IOP, corneal elasticity, and corneal geometry of in situ porcine corneas with a technique termed applanation optical coherence elastography (Appl-OCE) with single instrument. We utilize an ultrafast phase-sensitive optical coherence tomography system comprised of a 4X buffered Fourier domain mode-locked swept source laser with an Ascan rate of 1.5 MHz and a 7.3 kHz resonant scanner. The IOP was measured by imaging the response of in situ porcine corneas to a large force air-puff. As with other noncontact tonometers, the time when the cornea was applanated during the inwards and outwards motion was correlated to a measure air-pressure temporal profile. The IOP was also measured with a commercially available rebound tonometer for comparison. The stiffness of the corneas was assessed by directly imaging and analyzing the propagation of a focused micro air-pulse induced elastic wave, and the corneal geometry was obtained from the OCT structural image. Our results show that corneal thickness decreased as IOP increased, and that corneal stiffness increased with IOP. Moreover, the IOP measurements made by Appl-OCE were more closely correlated with the artificially set IOP than the rebound tonometer, demonstrating the capabilities of Appl-OCE to measure corneal stiffness, eye-globe IOP, and corneal geometry with a single instrument.

  9. Regulation of corneal stroma extracellular matrix assembly.

    PubMed

    Chen, Shoujun; Mienaltowski, Michael J; Birk, David E

    2015-04-01

    The transparent cornea is the major refractive element of the eye. A finely controlled assembly of the stromal extracellular matrix is critical to corneal function, as well as in establishing the appropriate mechanical stability required to maintain corneal shape and curvature. In the stroma, homogeneous, small diameter collagen fibrils, regularly packed with a highly ordered hierarchical organization, are essential for function. This review focuses on corneal stroma assembly and the regulation of collagen fibrillogenesis. Corneal collagen fibrillogenesis involves multiple molecules interacting in sequential steps, as well as interactions between keratocytes and stroma matrix components. The stroma has the highest collagen V:I ratio in the body. Collagen V regulates the nucleation of protofibril assembly, thus controlling the number of fibrils and assembly of smaller diameter fibrils in the stroma. The corneal stroma is also enriched in small leucine-rich proteoglycans (SLRPs) that cooperate in a temporal and spatial manner to regulate linear and lateral collagen fibril growth. In addition, the fibril-associated collagens (FACITs) such as collagen XII and collagen XIV have roles in the regulation of fibril packing and inter-lamellar interactions. A communicating keratocyte network contributes to the overall and long-range regulation of stromal extracellular matrix assembly, by creating micro-domains where the sequential steps in stromal matrix assembly are controlled. Keratocytes control the synthesis of extracellular matrix components, which interact with the keratocytes dynamically to coordinate the regulatory steps into a cohesive process. Mutations or deficiencies in stromal regulatory molecules result in altered interactions and deficiencies in both transparency and refraction, leading to corneal stroma pathobiology such as stromal dystrophies, cornea plana and keratoconus. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Regulation of Corneal Stroma Extracellular Matrix Assembly

    PubMed Central

    Chen, Shoujun; Mienaltowski, Michael J.; Birk, David E.

    2014-01-01

    The transparent cornea is the major refractive element of the eye. A finely controlled assembly of the stromal extracellular matrix is critical to corneal function, as well as in establishing the appropriate mechanical stability required to maintain corneal shape and curvature. In the stroma, homogeneous, small diameter collagen fibrils, regularly packed with a highly ordered hierarchical organization, are essential for function. This review focuses on corneal stroma assembly and the regulation of collagen fibrillogenesis. Corneal collagen fibrillogenesis involves multiple molecules interacting in sequential steps, as well as interactions between keratocytes and stroma matrix components. The stroma has the highest collagen V:I ratio in the body. Collagen V regulates the nucleation of protofibril assembly, thus controlling the number of fibrils and assembly of smaller diameter fibrils in the stroma. The corneal stroma is also enriched in small leucine-rich proteoglycans (SLRPs) that cooperate in a temporal and spatial manner to regulate linear and lateral collagen fibril growth. In addition, the fibril-associated collagens (FACITs) such as collagen XII and collagen XIV have roles in the regulation of fibril packing and inter-lamellar interactions. A communicating keratocyte network contributes to the overall and long-range regulation of stromal extracellular matrix assembly, by creating micro-domains where the sequential steps in stromal matrix assembly are controlled. Keratocytes control the synthesis of extracellular matrix components, which interact with the keratocytes dynamically to coordinate the regulatory steps into a cohesive process. Mutations or deficiencies in stromal regulatory molecules result in altered interactions and deficiencies in both transparency and refraction, leading to corneal stroma pathobiology such as stromal dystrophies, cornea plana and keratoconus. PMID:25819456

  11. Effect of vitreous length and trephine size disparity on post-DALK refractive status.

    PubMed

    Javadi, Mohammad Ali; Feizi, Sepehr; Rastegarpour, Ali

    2011-04-01

    To evaluate the effect of vitreous length (distance between posterior lens surface and vitreoretinal interface) and donor-recipient disparity on the refraction and keratometric astigmatism after deep anterior lamellar keratoplasty (DALK). In this retrospective comparative study, 85 eyes of 83 patients with keratoconus underwent DALK using the big-bubble technique. A 0.25-mm oversize donor was used for a vitreous length of ≥ 16.0 mm, and a 0.50-mm oversize donor for a vitreous length of <16.0 mm. At least 3 months after complete suture removal, spherical equivalent refractive error (SE), keratometric astigmatism, and mean keratometry were compared between the 2 groups. Multiple regression analysis was performed in group 1 to investigate the correlation between vitreous length and SE, between vitreous length and keratometric astigmatism, and between mean keratometry and SE. Mean patient age was 26.5 ± 7.7 years, and they were followed for 22 ± 10 months postoperatively. Seventy-five eyes received a 0.25-mm oversize donor (group 1), and 10 had a donor oversized by 0.50 mm (group 2). Compared with group 1, the patients of group 2 had a significantly steeper cornea (46.83 ± 2.0 vs. 48.29 ± 1.9 diopters, respectively; P = 0.01). SE and keratometric astigmatism in group 1 did not significantly differ from those in group 2. In group 1, there was a significant association between vitreous length and SE and between mean keratometry and SE but not between vitreous length and keratometric astigmatism. In DALK, a donor oversized by 0.25 mm is advisable for elongated keratoconic eyes, whereas a 0.50-mm oversize donor is advocated for small ones.

  12. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    PubMed Central

    Shetty, Rohit; Agrawal, Aarti; Deshmukh, Rashmi; Kaweri, Luci; Rao, Harsha L; Nagaraja, Harsha; Jayadev, Chaitra

    2017-01-01

    Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL) haze on the measurement and repeatability of pachymetry and mean keratometry (Km) of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL) underwent imaging with a scanning slit imaging device (Orbscan II) and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei). Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT) and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05) significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively). Km values were affected by haze when measured with the Pentacam HR (P < 0.05). The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively), Km values (P = 0.4 and 0.6, respectively), repeatability of TCT (P = 0.1 in both zones), and Km (P = 0.5 and 0.1, respectively) with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution. PMID:28513495

  13. Evolving indications for and trends in keratoplasty in British Columbia, Canada, from 2002 to 2011: a 10-year review.

    PubMed

    Tan, Johnson C H; Holland, Simon P; Dubord, Paul J; Moloney, Gregory; McCarthy, Martin; Yeung, Sonia N

    2014-03-01

    The aim of this study was to report the evolving indications for keratoplasty and the shift in the type of keratoplasty performed in British Columbia, Canada, over a 10-year period from 2002 to 2011. This was a retrospective database review of all the records of corneal transplant tissues at the Eye Bank of British Columbia, Canada, from January 2002 to December 2011. The patient demographics, indications, and types of transplant performed were analyzed. A total of 4843 corneal transplants were performed in 3742 patients (1968 male and 1774 female) from January 2002 to December 2011. The number of keratoplasties performed ranged from 420 in 2008 to 578 in 2011. The top 4 indications over the 10-year period were Fuchs endothelial dystrophy (FED; 18.9%), aphakic/pseudophakic bullous keratopathy (17.4%), regraft (17.1%), and keratoconus (15.5%). Penetrating keratoplasty (PKP) accounted for 86.5% (4191 transplants) of all keratoplasties performed. Since the introduction of Descemet stripping automated endothelial keratoplasty (DSAEK) in 2007, there was a significant increase in the number of DSAEKs (P < 0.0001) performed and a statistical decline in the number of PKPs (P < 0.0001) performed. Despite only 30 deep anterior lamellar keratoplasties being performed, an increasing trend was observed after 2008 (P = 0.0087). A decreasing trend in PKPs and an increasing trend in DSAEKs were observed for surgeries performed for FED, aphakic/pseudophakic bullous keratopathy, and regraft. FED has become the top indication for performing a keratoplasty over the 10-year period. There was a shift from PKP to DSAEK performed for endothelial failure. Although the number of deep anterior lamellar keratoplasty surgeries was small, there was a significant increasing trend.

  14. Corneal staining patterns in vernal keratoconjunctivitis: the new VKC-CLEK scoring scale.

    PubMed

    Leonardi, Andrea; Lazzarini, Daniela; La Gloria Valerio, Alvise; Scalora, Tania; Fregona, Iva

    2018-01-24

    To propose a new scoring system in the assessment of ocular surface epithelial damage in vernal keratoconjunctivitis (VKC). 25 consecutive patients with VKC (50 eyes) were evaluated using the Quality of Life in children with VKC (QUICK) questionnaire and objective clinical measures: fluorescein and lissamine green staining and cornea confocal microscopy (Heidelberg Retina Tomography 3). Oxford, Van Bljsterweld and a new system, the VKC-Collaborative Longitudinal Evaluation of Keratoconus study (CLEK) (VKC-CLEK) scores, were used to evaluate the epithelial damage after staining. Mean Oxford and VKC-CLEK scores were significantly different after fluorescein staining (P<0.001), but significantly correlated (P<0.001; r=0.649). The same data were obtained comparing Van Bljsterweld and VKC-CLEK after lissamine green staining (P<0.001; r=0.760). In patient with limbal VKC, a statistically significant difference was found comparing new VKC-CLEK scores and Oxford or Van Bljsterweld scores (P<0.001), but not in tarsal VKC. A statistically superior concordance was found between QUICK and VKC-CLEK scores compared with standard staining scores values (P<0.001). Oxford and Van Bijsterveld scores are not adequate for the evaluation of the epithelial damage in patients with limbal VKC because the staining patterns considered for these tests do not correspond to the staining patterns in patients with VKC. We propose a new scoring system, VKC-CLEK, to better evaluate both limbal and tarsal epithelial damage in patients with VKC. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Outcomes of photorefractive keratectomy in patients with atypical topography.

    PubMed

    Movahedan, Hossein; Namvar, Ehsan; Farvardin, Mohsen

    2017-11-01

    Photorefractive keratectomy (PRK) is at risk of serious complications such as corneal ectasia, which can reduce corrected distance visual acuity. The rate of complications of PRK is higher in patients with atypical topography. To determine the outcomes of photorefractive keratectomy in patients with atypical topography. This cross-sectional study was done in 2015 in Shiraz in Iran. We included 85 eyes in this study. The samples were selected using a simple random sampling method. All patients were under evaluation for uncorrected distance visual acuity, corrected distance visual acuity, manifest refraction, corneal topography, central corneal thickness using pentacam, slit-lamp microscopy, and detailed fondus evaluation. The postoperative examination was done 1-7 years after surgery. Data were analyzed using IBM SPSS 21.0 version. To analyze the data, descriptive statistics (frequency, percentage, mean, and standard deviation), chi-square, and independent samples t-test were used. We studied 85 eyes. Among the patients, 23 (27.1%) were male and 62 (72.9%) were female. Mean age of the participants was 28.25±5.55 years. Mean postoperative refraction was - 0.37±0.55 diopters. Keratoconus or corneal ectasia was not reported in any patient in this study. There was no statistically significant difference between SI index before and after operation (p=0.736). Mean preoperative refraction was -3.84 ± 1.46 diopters in males and -4.20±1.96 diopters in females; thus there was not statistically significant difference (p = 0.435). PRK is a safe and efficient photorefractive surgery and is associated with low complication rate in patients with atypical topography.

  16. Silicone Hydrogel and Rigid Gas-Permeable Scleral Lens Tear Exchange.

    PubMed

    Paugh, Jerry R; Chen, Elaine; Heinrich, Colton; Miller, Heidi; Gates, Tiffany; Nguyen, Andrew Loc; Edrington, Timothy; Weissman, Barry A

    2018-03-01

    To quantify tear elimination rate (ER) underneath silicone hydrogel (Si-Hy) and scleral gas permeable (GP) contact lenses (CLs). Subjects successfully using either well-fitting soft Si-Hy CLs or scleral GP CLs were recruited. Most scleral GP CL wearers had irregular corneas (e.g., keratoconus). An objective fluorometer measured decay of fluorescein isothiocyanate dextran dye signal (70 kD MW) from which the tear ER in %/min was calculated. For GP scleral lenses, the ER was determined for both the initial settling period and the 30- to 60-min period, and without lenses. All ERs were calculated from 5 to 30 min to avoid reflex tearing effects. Fourteen soft Si-Hy CL and 12 scleral GP CL wearers completed the study. The ER for the scleral GP CL wearers averaged 0.57 (±0.6) %/min for the 0- to 30-min and 0.42 (±0.5) %/min for the 30- to 60-min period (P=0.515). Non-CL wear tear ER in these same subjects averaged 34.17 (±15.9) %/min and was significantly different versus both scleral GP wear periods (both P values <0.001). The ER for the soft Si-Hy CL wearers, 5 to 30 min, averaged 6.09 (±2.8) %/min. Our data demonstrate significantly less ER in well-fit scleral GP CL wearers compared with soft Si-Hy CL wearers for both the settling and longer wear periods (both P values <0.001). Moreover, slightly greater tear exchange was observed during the scleral GP CL settling period than later, which may reflect a change over time in tear vault thickness.

  17. Surgical therapies for corneal perforations: 10 years of cases in a tertiary referral hospital

    PubMed Central

    Yokogawa, Hideaki; Kobayashi, Akira; Yamazaki, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa

    2014-01-01

    Purpose To report surgical therapies for corneal perforations in a tertiary referral hospital. Methods Thirty-one eyes of 31 patients (aged 62.4±18.3 years) with surgically treated corneal perforations from January 2002 to July 2013 were included in this study. Demographic data such as cause of corneal perforation, surgical procedures, and visual outcomes were retrospectively analyzed. Results The causes of corneal perforation (n=31) were divided into infectious (n=8, 26%) and noninfectious (n=23, 74%) categories. Infectious causes included fungal ulcer, herpetic stromal necrotizing keratitis, and bacterial ulcer. The causes of noninfectious keratopathy included corneal melting after removal of a metal foreign body, severe dry eye, lagophthalmos, canaliculitis, the oral anticancer drug S-1, keratoconus, rheumatoid arthritis, neurotrophic ulcer, atopic keratoconjunctivitis, and unknown causes. Initial surgical procedures included central large corneal graft (n=17), small corneal graft (n=7), and amniotic membrane transplantation (n=7). In two cases the perforation could not be sealed during the first surgical treatment and required subsequent procedures. All infectious keratitis required central large penetrating keratoplasty to obtain anatomical cure. In contrast, several surgical options were used for the treatment of noninfectious keratitis. After surgical treatment, anatomical cure was obtained in all cases. Mean postoperative best corrected visual acuity was better at 6 months (logMAR 1.3) than preoperatively (logMAR 1.8). Conclusion Surgical therapies for corneal perforations in our hospital included central large lamellar/penetrating keratoplasty, small peripheral patch graft, and amniotic membrane transplantation. All treatments were effective. Corneal perforation due to the oral anticancer drug S-1 is newly reported. PMID:25378903

  18. The New Zealand National Eye Bank: survival and visual outcome 1 year after penetrating keratoplasty.

    PubMed

    Patel, Hussain Y; Ormonde, Sue; Brookes, Nigel H; Moffatt, S Louise; Sherwin, Trevor; Pendergrast, David G C; McGhee, Charles N J

    2011-07-01

    To identify potential donor, recipient, surgical, and postoperative factors that may influence survival and visual outcome of penetrating keratoplasty (PKP). As part of a prospective longitudinal study, the electronic records of the New Zealand National Eye Bank were analyzed for the 10-year period from 1994-2003. Both univariate and multivariate analysis was performed. During the study period, the New Zealand National Eye Bank supplied 1820 corneas for PKP and 1629 (90%) had 1-year follow-up data. Overall, the 1-year survival rate was 87% (n = 1429). Donor factors including age, donor source, cause of death, death-to-preservation interval, endothelial cell density, donor lens status, and storage duration, were not significantly associated with decreased survival. The leading cause of PKP failure was irreversible rejection (7%, n = 114). Independent risk factors identified for decreased PKP survival were: 1 or more episodes of reversible rejection, active inflammation at PKP, preexisting corneal vascularization, intraoperative complications, small graft size (≤ 7.25 mm), large graft size (≥ 8.5 mm), preoperative glaucoma, and a preoperative diagnosis of regraft or trauma. A best-corrected Snellen visual acuity of 6/12 or better was achieved in 60% of eyes [mean: 6/15 (logarithm of the minimum angle of resolution 0.40)]. Keratoconus and Fuchs endothelial dystrophy were the diagnoses with best survival and visual outcome, whereas, bullous keratopathy, trauma or noninfective keratitis were associated with poorer visual outcome. Several independent risk factors were identified that significantly influenced PKP first year survival outcome. This information is valuable to patients and surgeons with respect to determining prognosis and clinical decision making.

  19. Clinical and epidemiological aspects of cornea transplant patients of a reference hospital.

    PubMed

    Cruz, Giovanna Karinny Pereira; Azevedo, Isabelle Campos de; Carvalho, Diana Paula de Souza Rego Pinto; Vitor, Allyne Fortes; Santos, Viviane Euzébia Pereira; Ferreira, Marcos Antonio

    2017-06-08

    clinically characterizing cornea transplant patients and their distribution according to indicated and post-operative conditions of cornea transplantation, as well as estimating the average waiting time. a cross-sectional, descriptive and analytical study performed for all cornea transplants performed at a reference service (n=258). Data were analyzed using Statistical Package for the Social Sciences, version 20.0. the main indicator for cornea transplant was keratoconus. The mean waiting time for the transplant was approximately 5 months and 3 weeks for elective transplants and 9 days for urgent cases. An association between the type of corneal disorder with gender, age, previous surgery, eye classification, glaucoma and anterior graft failure were found. keratoconus was the main indicator for cornea transplant. Factors such as age, previous corneal graft failure (retransplantation), glaucoma, cases of surgeries prior to cornea transplant (especially cataract surgery) may be related to the onset corneal endothelium disorders. caracterizar clínicamente los pacientes trasplantados y su distribución, con descripción de las condiciones indicadoras y posoperatorias de los trasplantes de córneas, así como estimar el tiempo promedio en la fila de espera. estudio epidemiológico, transversal, descriptivo y analítico, realizado con todos los trasplantes de córnea realizados en un servicio de referencia (n=258). Los datos fueron analizados con el software Statistical Package for the Social Sciences, versión 20.0. la principal condición indicadora para el trasplante de córnea fue el queratocono. El tiempo promedio en fila de espera para realización del trasplante fue de aproximadamente 5 meses y tres semanas, para trasplantes electivos y de 9 días para los casos de urgencia. Existió asociación entre el tipo de disturbio de la córnea con: sexo, intervalo etario, cirugía previa, clasificación del ojo, glaucoma y rechazo del injerto anterior. el queratocono fue

  20. Perilimbal bevacizumab injection for interface neovascularization after deep anterior lamellar keratoplasty.

    PubMed

    Foroutan, Alireza; Fariba, Beigzadeh; Pejman, Bakhtiari; Mahmoud, Joshaghani; Khalil, Ghasemi Falavarjani; Arash, Ehteshami Afshar; Foroutan, Pooria

    2010-11-01

    To evaluate the effect of perilimbal bevacizumab injection on neovascularization at the interface of donor and recipient tissues after deep anterior lamellar keratoplasty (DALK). This interventional case series included 4 patients with interface neovascularization after DALK (3 patients with advanced keratoconus and 1 patient with scarring because of herpetic keratitis). Bevacizumab (2.5 mg/0.1 mL) was injected subconjunctivally near the limbus adjacent to the abnormal blood vessels. Depending on regression of new vessels, injections were repeated. If neovascularization occurred in more than 1 quadrant, injections were administered at 2 sites (2.5 mg for each injection). Total corneal neovascularization, longest neovascular length, and degree of neovascular circumference were evaluated by digital slit lamp corneal photography before injection and 1 week, 1, 3, and 6 months afterward. The mean follow-up period was 14 ± 7.52 months from the first bevacizumab injection. Corneal neovascularization, on average,was 33.70% ± 7.8% (SD) of the total corneal surface before the injections, which decreased to 4.83% ± 3.3% (P = 0.005, t test) at the last follow-up examination. Mean degree of neovascularized circumference decreased from 165 degrees before injection to 77.5 degrees (P = 0.023) at the last follow-up examination. Mean longest neovascularized length decreased from 6.714 mm before injection to 1.497 mm (P = 0.021) at the last follow-up examination. At the end of the study, all patients had clear grafts with no sign of graft failure. Mean best-corrected visual acuity before injection was 20/100, which improved to 20/30 at the last examination. This small case series suggests that perilimbal bevacizumab injection is safe and effective for partial regression of new blood vessels at the interface of donor and recipient tissues after DALK and may effectively prevent graft rejection.

  1. Management of postkeratoplasty astigmatism by paired arcuate incisions with compression sutures.

    PubMed

    Fares, Usama; Mokashi, Aashish A; Al-Aqaba, Mouhamed Ali; Otri, Ahmad Muneer; Miri, Ammar; Dua, Harminder Singh

    2013-04-01

    To analyse the efficacy of paired arcuate incisions and compression sutures technique in the management of post penetrating keratoplasty (PK) astigmatism. A paired arcuate incision with compression sutures procedure was used to treat 26 eyes with post-PK astigmatism ranging from 6.00 to 16.50 dioptres (D). The incisions were placed at the 7.0 mm optical zone inside the graft-host junction at a depth of 80% of corneal thickness. A 45° paired arc length was planned for eyes with preoperative astigmatism between 6D and 9D, and a 60° paired arc length was planned for eyes with preoperative astigmatism of >9D. At 3 months, corneal topography and refraction was performed and suture(s) removed if indicated. Net and vector astigmatism changes were calculated to determine the efficacy of the procedure. The indications for PK included keratoconus, Fuch's endothelial dystrophy, pseudophakic bullous keratopathy and corneal scar. There was a statistically significant reduction in the mean magnitude of astigmatism from 9.66 ± 2.90D preoperatively to 4.37 ± 2.53D postoperatively in the whole group. The mean decrease in the astigmatism was 4.37 ± 2.05D (58.4%) and 6.23 ± 3.63D (52.6%) in patients with 6-9D and >9D, respectively. Vector power calculations also showed a significant astigmatism reduction in all groups. The safety and efficacy indices were 1.40 and 0.28, respectively. Manual astigmatic keratotomy is a viable technique with relatively good safety and efficacy outcomes. Based on the results we propose that increasing the arc length to a minimum of 60° for astigmatism of 6-9D, and to 75° for astigmatism >9D, is likely to have a greater beneficial effect.

  2. Can possible toxic effect of ultraviolet-A after corneal cross-linking be prevented? In vitro transmittance study of contact lenses at 370 nm wavelength.

    PubMed

    Bilgihan, Kamil; Yuksel, Erdem; Deniz, Nuriye Gokcen; Yuksel, Nilay

    2015-01-01

    Corneal collagen cross linking (CCL) with ultraviolet A (UVA) has been proposed as a treatment for the progression of corneal ectasia associated with keratoconus and post-laser-assisted in situ keratomileusis (LASIK) ectasia. Despite the reports about safety of procedure, we consider that UVA of sunlight can effect riboflavin saturated and de-epitelizated cornea early after CCL. To evaluate the UVA blockage capability of 11 different silicone hydrogel contact lenses which are widely used after CCL treatment. Eleven different silicone hydrogel and daily disposable contact lenses were evaluated. The UVA light at 365 nm wavelength for UVA source and UV light meter to measure UVA radiation were used. 3, 9 and 18 mW/cm(2) power of UV radiance was applied centrally to the each type of contact lenses. The power of UVA transmittance for each radiance and percentage of blockage were evaluated for each brand. Also, protection factor (PF) was calculated. The senofilcon A and narafilcon A had the highest blockage and lowest transmittance (p = 0.02). PF was significantly higher in the senofilcon A and narafilcon A at 3, 9 and 18 mW/cm(2) (p = 0.0001). And also, the hilafilcon B, filcon IV, nelfilcon A, enfilcon A, lotrafilcon A and lotrafilcon B had the highest UVA transmittance. The narafilcon A and the senofilcon A may be a good options for epithelial healing after CCL procedure to protect the cornea from UVA of sunlight. And also, the hilafilcon B, filcon IV, nelfilcon A, enfilcon A, lotrafilcon A and lotrafilcon B contact lenses that have high-UVA transmittance feature can be a treatment choice for contact lens-assisted CCL technique in thin corneas.

  3. Characterization of Ocular Biomechanics in Pellucid Marginal Degeneration.

    PubMed

    Lenk, Janine; Haustein, Michael; Terai, Naim; Spoerl, Eberhard; Raiskup, Frederik

    2016-04-01

    This study sought to investigate the diagnostic capacity of corneal biomechanical response parameters in a group of patients with pellucid marginal degeneration (PMD) using the Ocular Response Analyzer (ORA) and Corvis ST devices. In this prospective clinical study, we used the Corvis ST and ORA devices to investigate the ocular biomechanics of patients with PMD. Eighty-one eyes were included, and 2 study groups were formed: the PMD group (the study group, n = 29) and the control group (n = 52). We focused on 13 biomechanical parameters. Statistical analysis was performed using SPSS. Biomechanical parameters for the 2 groups were compared using analysis of covariance. The ORA results demonstrated that the Keratoconus Match Index was significantly lower in the PMD group than in the control group (0.031 ± 0.37 vs. 0.79 ± 0.33; P = 0.001). The 2 groups did not significantly differ with respect to intraocular pressure- and central corneal thickness-adjusted values for corneal hysteresis or corneal resistance factor. Regarding the Corvis parameters, differences between the control and PMD groups were detected for CorWmax amp (control 1.01 ± 0.01, PMD 1.06 ± 0.01; P = 0.020) and CorA2 t (control 21.78 ± 0.03, PMD 21.66 ± 0.04; P = 0.0003). We identified 2 Corvis parameters that could be used to characterize PMD and differentiate PMD corneas from normal corneas. These parameters support the hypothesis that there is significantly less deformation of the central cornea in PMD corneas than in healthy corneas. However, because useful "first-line" diagnostic devices for diagnosing PMD (such as Pentacam and the ORA) exist, the Corvis ST serves as an additional diagnostic tool that can also be used for long-term monitoring after diagnosis confirmation.

  4. Clinical characteristics and causes of visual impairment in a low vision clinic in northern Jordan.

    PubMed

    Bakkar, May M; Alzghoul, Eman A; Haddad, Mera F

    2018-01-01

    The aim of the study was to identify causes of visual impairment among patients attending a low vision clinic in the north of Jordan and to study the relevant demographic characteristics of these patients. The retrospective study was conducted through a review of clinical records of 135 patients who attended a low vision clinic in Irbid. Clinical characteristics of the patients were collected, including age, gender, primary cause of low vision, best corrected visual acuity, and current prescribed low vision aids. Descriptive statistics analysis using numbers and percentages were calculated to summarize categorical and nominal data. A total of 135 patients (61 [45.2%] females and 74 [54.8%] males) were recruited in the study. Mean age ± standard deviation for the study population was 24.53 ± 16.245 years; age range was 5-90 years. Of the study population, 26 patients (19.3%) had mild visual impairment, 61 patients (45.2%) had moderate visual impairment, 27 patients (20.0%) had severe visual impairment, and 21 patients (15.6%) were blind. The leading causes of visual impairment across all age groups were albinism (31.9%) and retinitis pigmentosa (RP) (18.5%). Albinism also accounted for the leading cause of visual impairment among the pediatric age group (0-15 years) while albinism, RP, and keratoconus were the primary causes of visual impairment for older patients. A total of 59 patients (43.7%) were given low vision aids either for near or distance. The only prescribed low vision aids for distances were telescopes. For near, spectacle-type low vision aid was the most commonly prescribed low vision aids. Low vision services in Jordan are still very limited. A national strategy programme to increase awareness of low vision services should be implemented, and health care policies should be enforced to cover low vision aids through the national medical insurance.

  5. Corneal curvature, pachymetry, and endothelial cell density in Marfan syndrome.

    PubMed

    Konradsen, Tiina R; Koivula, Annemari; Kugelberg, Maria; Zetterström, Charlotta

    2012-06-01

    To evaluate corneal curvature, pachymetry, and endothelial cell density (ECD) in Marfan syndrome (MFS). A case-control study in which K values, pachymetry, and ECD were compared in 39 MFS eyes and 40 control eyes matched for age and refraction was conducted. MFS eyes with lens subluxation also were compared with eyes without subluxation. The mean K(med) value in MFS eyes was lower than in the control eyes, 42.2 ± 1.9 versus 43.4 ± 1.4 dioptres (D), respectively (p = 0.02). Fifteen MFS eyes (38%) and three control eyes (8%) had K(med) values below 41.5 D (p = 0.0012). MFS eyes had generally more corneal astigmatism than control eyes, 1.1 ± 0.9 versus 0.8 ± 0.4 D (p = 0.035), and MFS eyes with lens subluxation had more corneal astigmatism than those without, 1.6 ± 1.1 versus 0.6 ± 0.3 D (p = 0.0002). Nine MFS eyes with corneal astigmatism exceeding 1.5 D also had a subluxated lens. No eyes had keratoconus. The mean pachymetry value was lower in MFS eyes compared to the controls, 485 ± 54.5 versus 514 ± 37.3 μm (p = 0.007); 24 MFS eyes (62%) and 10 control eyes (25%) had measurements below 500 μm (p = 0.01). The mean ECD values were similar in MFS and control eyes, 2815 ± 430 versus 2858 ± 458 cells/mm(2) (p = 0.66). The mean K value, pachymetry, and ECD values did not differ between MFS eyes with and without lens subluxation. Decreased K values and pachymetry could indicate MFS regardless of subluxation. High corneal astigmatism is associated with subluxation in MFS. Subluxation should be identified in MFS eyes with high corneal astigmatism. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  6. Use of a "small-bubble technique" to increase the success of Anwar's "big-bubble technique" for deep lamellar keratoplasty with complete baring of Descemet's membrane.

    PubMed

    Parthasarathy, Anand; Por, Yong Ming; Tan, Donald T H

    2007-10-01

    To describe a quick and simple "small-bubble" technique to immediately determine the success of attaining complete Descemet's membrane (DM) separation from corneal stroma through Anwar's "big-bubble" technique of deep anterior lamellar keratoplasty (DALK) for complete stromal removal. A partial trephination was followed by a lamellar dissection of the anterior stroma. Deep stromal air injection was then attempted to achieve the big bubble to help separate the stroma from the DM. To confirm that a big bubble had been achieved, a small air bubble was injected into the anterior chamber (AC) through a limbal paracentesis. If the small bubble is then seen at the corneal periphery, it confirms that the big-bubble separation of DM was successful because the convex nature of the bubble will cause it to protrude posteriorly, forcing the small AC bubble to the periphery. If the small AC bubble is not seen in the corneal periphery, this means that it is present in the centre, beneath the opaque corneal stroma, and therefore the big bubble has not been achieved. We used the small-bubble technique to confirm the presence of the big bubble in three (one keratoconus, one interstitial keratitis and one dense corneal scar) out of 41 patients who underwent DALK. The small-bubble technique confirmed that the big bubble was achieved in the eye of all three patients. Complete stromal removal with baring of the DM was achieved, and postoperatively all three eyes achieved best corrected vision of 6/6. The small-bubble technique can be a useful surgical tool for corneal surgeons attempting lamellar keratoplasty using the big-bubble technique. It helps in confirming the separation of DM from the deep stroma, which is important in achieving total stromal replacement. It will help to make the transition to lamellar keratoplasty smoother, enhance corneal graft success and improve visual outcomes in patients.

  7. Human SLC4A11-C functions as a DIDS-stimulatable H+(OH−) permeation pathway: partial correction of R109H mutant transport

    PubMed Central

    Kao, Liyo; Azimov, Rustam; Abuladze, Natalia; Newman, Debra

    2014-01-01

    The SLC4A11 gene mutations cause a variety of genetic corneal diseases, including congenital hereditary endothelial dystrophy 2 (CHED2), Harboyan syndrome, some cases of Fuchs' endothelial dystrophy (FECD), and possibly familial keratoconus. Three NH2-terminal variants of the human SLC4A11 gene, named SLC4A11-A, -B, and -C are known. The SLC4A11-B variant has been the focus of previous studies. Both the expression of the SLC4A11-C variant in the cornea and its functional properties have not been characterized, and therefore its potential pathophysiological role in corneal diseases remains to be explored. In the present study, we demonstrate that SLC4A11-C is the predominant SLC4A11 variant expressed in human corneal endothelial mRNA and that the transporter functions as an electrogenic H+(OH−) permeation pathway. Disulfonic stilbenes, including 4,4′-diisothiocyano-2,2′-stilbenedisulfonate (DIDS), 4,4′-diisothiocyanatodihydrostilbene-2,2′-disulfonate (H2DIDS), and 4-acetamido-4′-isothiocyanato-stilbene-2,2′-disulfonate (SITS), which are known to bind covalently, increased SLC4A11-C-mediated H+(OH−) flux by 150–200% without having a significant effect in mock-transfected cells. Noncovalently interacting 4,4′-diaminostilbene-2,2′-disulfonate (DADS) was without effect. We tested the efficacy of DIDS on the functionally impaired R109H mutant (SLC4A11-C numbering) that causes CHED2. DIDS (1 mM) increased H+(OH−) flux through the mutant transporter by ∼40–90%. These studies provide a basis for future testing of more specific chemically modified dilsulfonic stilbenes as potential therapeutic agents to improve the functional impairment of specific SLC4A11 mutant transporters. PMID:25394471

  8. Visual impairment in adult people with moderate, severe, and profound intellectual disability.

    PubMed

    Warburg, M

    2001-10-01

    To assess visual impairment in adults with intellectual disability after de-institutionalisation. The county has a population of 385 483 persons of 18 years and older; 961 were moderately, severely or profoundly intellectually impaired (ID), 837 of them (87 %) participated in the investigation. Visual acuity, VA: Østerberg picture charts and reduced copies for near vision could be used in 71% of the patients. Teller preferential looking procedure was applied to people who were unable to cooperate with the picture charts. When examined with picture wall chart VA 0.3-> or =0.10) was found in 10.8%, severe low vision in 1.2% (VA <0.10-> or =0.05), and blindness (VA<0.05) in 3.8%. Poor near vision (<0.3) was present in 19%. Those assessed with Teller acuity cards had poorer vision than the others. It is possible that the low values of assessment with Teller cards represent a combination of gnostic and resolution deficiencies, which means that the results of grating VA and recognition VA are non-comparable. Ophthalmic disorders: The most widespread medical condition was cerebral visual impairment, the most frequent eye disorders were optic atrophy, high myopia, cataract, and keratoconus. Refraction: Refraction was assessed in 710 persons (85%), the most prevalent cause of visual impairment was uncorrected ametropia. Hypermetropia of >+1.50 was found in 151 of 710 subjects (21%), and spectacles were used by 106 (15%); myopia <-1.0 was present in 213 individuals (30%), 95 persons (13%) had lenses <-1.0. Resettled adult people with intellectual disability have a high prevalence of treatable visual impairment. A structured scheme of referral to optometric and ophthalmological care is essential if these people are to be given the care to which they are entitled.

  9. A case report of central toxic keratopathy in a patient post TransPRK (followed by corneal collagen cross-linking)

    PubMed Central

    Davey, Nicholas; Aslanides, Ioannis M; Selimis, Vasilis

    2017-01-01

    Purpose The purpose of this article is to report a case of central toxic keratopathy in a patient post transepithelial photorefractive keratectomy (TransPRK), followed immediately by corneal collagen cross-linking. Methods This article describes the case of a 26-year-old male after bilateral aberration-free, TransPRK laser (Schwind Amaris 750S). The procedure was performed for compound myopic astigmatism in November 2015, followed immediately by accelerated corneal collagen cross-linking for early keratoconus. Results From day 3 post-op, tear film debris underneath both contact lenses with corneal haze and early, progressive central anterior stromal opacity formation only in the left eye were noted. At 2 weeks post-op, the left eye was noted to have a significant hyperopic shift with central corneal thinning in the anterior stroma. A central anterior stromal dense opacity had formed in the left eye with the surrounding superficial stromal haze. As of month 2, the opacity gradually started to improve in size and density. The hyperopic shift peaked at 2 months and continued to improve, largely due to epithelial compensation with a gradual recovery of stromal thickness. Conclusion The question remains as to what provokes the typical central corneal necrosis/thinning in central toxic keratopathy. We hypothesize that the space between the contact lens and the corneal surface post TransPRK is prone to a “pseudo-interface pathology” that could mimic diffuse lamellar keratitis-like pathology. Suboptimal lid hygiene, resulting in tear film combinations of bacteria, inflammatory cells, matrix metalloproteinases and other proteolytic enzymes, contributes to the degradation of vulnerable, exposed collagen stromal tissue post TransPRK or any surface corneal ablation. Refractive surgeons should maintain a healthy lid margin and tear film, especially in contact lens wearers, to prevent potential complications in refractive surgery procedures. PMID:28450791

  10. A case report of central toxic keratopathy in a patient post TransPRK (followed by corneal collagen cross-linking).

    PubMed

    Davey, Nicholas; Aslanides, Ioannis M; Selimis, Vasilis

    2017-01-01

    The purpose of this article is to report a case of central toxic keratopathy in a patient post transepithelial photorefractive keratectomy (TransPRK), followed immediately by corneal collagen cross-linking. This article describes the case of a 26-year-old male after bilateral aberration-free, TransPRK laser (Schwind Amaris 750S). The procedure was performed for compound myopic astigmatism in November 2015, followed immediately by accelerated corneal collagen cross-linking for early keratoconus. From day 3 post-op, tear film debris underneath both contact lenses with corneal haze and early, progressive central anterior stromal opacity formation only in the left eye were noted. At 2 weeks post-op, the left eye was noted to have a significant hyperopic shift with central corneal thinning in the anterior stroma. A central anterior stromal dense opacity had formed in the left eye with the surrounding superficial stromal haze. As of month 2, the opacity gradually started to improve in size and density. The hyperopic shift peaked at 2 months and continued to improve, largely due to epithelial compensation with a gradual recovery of stromal thickness. The question remains as to what provokes the typical central corneal necrosis/thinning in central toxic keratopathy. We hypothesize that the space between the contact lens and the corneal surface post TransPRK is prone to a "pseudo-interface pathology" that could mimic diffuse lamellar keratitis-like pathology. Suboptimal lid hygiene, resulting in tear film combinations of bacteria, inflammatory cells, matrix metalloproteinases and other proteolytic enzymes, contributes to the degradation of vulnerable, exposed collagen stromal tissue post TransPRK or any surface corneal ablation. Refractive surgeons should maintain a healthy lid margin and tear film, especially in contact lens wearers, to prevent potential complications in refractive surgery procedures.

  11. Simultaneous and sequential implantation of intacs and verisyse phakic intraocular lens for refractive improvement in keratectasia.

    PubMed

    Moshirfar, Majid; Fenzl, Carlton R; Meyer, Jay J; Neuffer, Marcus C; Espandar, Ladan; Mifflin, Mark D

    2011-02-01

    To evaluate the safety, efficacy, and visual outcomes of simultaneous and sequential implantation of Intacs (Addition Technology, Inc, Sunnyvale, CA) and Verisyse phakic intraocular lens (AMO, Santa Ana, CA) in selected cases of ectatic corneal disease. John A. Moran Eye Center, University of Utah, UT. Prospective data were collected from 19 eyes of 12 patients (5 eyes, post-laser in situ keratomileusis ectasia and 14 eyes, keratoconus). Intacs segments were implanted followed by insertion of a phakic Verisyse lens at the same session (12 eyes) in the simultaneous group or several months later (7 eyes) in the sequential group. The uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest refraction were recorded at each visit. No intraoperative or postoperative complications were observed. At the last follow-up (19 ± 6 months), in the simultaneous group, mean spherical error was -0.79 ± 1.0 diopter (D) (range, -2.0 to +1.50 D) and cylindrical error +2.06 ± 1.21 D (range, +0.5 to +3.75 D). In the sequential group, at the last follow-up, at 36 ± 21 months, the mean spherical error was -1.64 ± 1.31 D (range, -3.25 to +1.0 D) and cylindrical error +2.07 ± 1.03 D (range, +0.75 to +3.25 D). There were no significant differences in mean uncorrected visual acuity or BSCVA between the 2 groups preoperatively or postoperatively. No eye lost lines of preoperative BSCVA. Combined insertion of Intacs and Verisyse was safe and effective in all cases. The outcomes of the simultaneous implantation of the Intacs and Verisyse lens in 1 surgery were similar to the results achieved with sequential implantation using 2 surgeries.

  12. Clinical Performance of a New Bitangential Mini-scleral Lens.

    PubMed

    Otten, Henny M; van der Linden, Bart J J J; Visser, Esther-Simone

    2018-06-01

    New bitangential mini-scleral lens designs provide a highly precise fit, follow the scleral shape, are comfortable to wear, and can correct residual astigmatism. This new scleral lens design complements the arsenal of medical contact lenses available to eye care practitioners. The aim of this study was to evaluate the subjective and objective performance of a new mini-scleral lens design with a bitangential periphery. In this observational study, data were collected for up to 15 months (median, 84 days; interquartile range, 76 days) from the left eyes of 133 patients fitted with this newly designed lens. Data were recorded during regular visits at Visser Contact Lens Practice's scleral lens clinics: diagnosis, clinical indication for scleral lenses, previous contact lens type, subjective performance, horizontal visible iris diameter, corrected distance visual acuity, and scleral lens fitting characteristics. The most common indication was keratoconus (45%), followed by irregular astigmatism (22%), keratoplasty (16.5%), ocular surface disease (13.5%), and other forms of irregular astigmatism (3%). The majority of patients (79%) scored comfort as either a 4 or 5 (out of 5), and 82% wore their lenses 12 hours or longer a day. Most lenses (81%) had a diameter of 16 mm (median, 16 mm; range, 15.5 to 17 mm) and were composed of Boston XO2 (46%), Menicon Z (44%), Boston XO (9%), or Boston Equalens II (1%). The median corrected distance visual acuity was 0.022 logarithm of the minimal angle of resolution (interquartile range, 0.155). The fitting characteristics revealed optimal values for centration and movement in 91% and 83%, respectively. Finally, the median stabilization axis was 50 degrees. New mini-scleral lenses with bitangential peripheral geometry yield satisfactory clinical results and good subjective performance and are therefore an effective option for managing patients who have irregular astigmatism or other corneal pathology.

  13. Longitudinal Outcomes of U.S. Air Force Pilot Applicants With Waivered Astigmatism.

    PubMed

    Andrus, David E; Haynes, Jared T; Wright, Steven T

    2017-03-01

    Current U.S. Air Force medical standards allow applicants to enter pilot training with up to 1.50 D of astigmatism. However, waivers are considered for individuals with up to 3.00 D of astigmatism. Although typically a benign finding, higher levels of astigmatism may be progressive and can be associated with corneal ectasia (e.g., keratoconus or pellucid marginal degeneration) leading to reduced visual acuity with spectacles and/or soft contact lenses. The goal of this study was to evaluate the long-term outcomes of pilot applicants waivered into training with astigmatism exceeding the aeromedical standard. Subjects were identified on the basis of their enrollment in the Excessive Astigmatism Management Group maintained by the Aeromedical Consultation Service, Ophthalmology branch at Wright-Patterson Air Force Base, Ohio. Metrics evaluated included refractive status, visual acuity, aeromedical waiver status, safety data, and the development of corneal ectasia. Seventy-six subjects were tracked for up to 10 years, with an average follow-up period of 5.5 years. Mean astigmatism at initial examination was 1.91 D, although mean astigmatism on the basis of the most recent examination was 2.19 D. Subjects with excessive astigmatism who were waivered into pilot training showed an average increase in astigmatism of slightly less than 0.05 D annually, which equates to a total increase in astigmatism of approximately 0.25 D for the duration of the study. No subjects developed ectasia or were disqualified from flying for vision or refractive reasons. No mishaps were identified with vision being a causative or contributing factor. This study supports continuation of current Air Force waiver policy, although a longer follow-up period is required to consider modifying the aeromedical standard for astigmatism. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  14. Intraocular pressure values obtained by ocular response analyzer, dynamic contour tonometry, and goldmann tonometry in keratokonic corneas.

    PubMed

    Bayer, Atilla; Sahin, Afsun; Hürmeriç, Volkan; Ozge, Gökhan

    2010-01-01

    To determine the agreement between dynamic contour tonometer (DCT), Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA) in keratoconic corneas and to find out the effect of corneal biomechanics on intraocular pressure (IOP) measurements obtained by these devices. IOP was measured with the ORA, DCT, and GAT in random order in 120 eyes of 61 keratoconus patients. Central corneal thickness (CCT) and keratometry were measured after all IOP determinations had been made. The mean IOP measurement by the ORA and DCT was compared with the measurement by the GAT, using Student t test. Bland-Altman analysis was performed to assess the clinical agreement between these methods. The effect of corneal hysteresis (CH), corneal resistance factor (CRF), and CCT on measured IOP was explored by multiple backward stepwise linear regression analysis. The mean±SD patient age was 30.6±11.2 years. The mean±SD IOP measurement obtained with GAT, ORA Goldmann-correlated IOP (IOPg), ORA corneal-compensated IOP (IOPcc), and DCT was 10.96±2.8, 10.23±3.5, 14.65±2.8, and 15.42±2.7 mm Hg, respectively. The mean±SD CCT was 464.08±58.4 microns. The mean difference between IOPcc and GAT (P<0.0001), IOPcc and DCT (P<0.001), GAT and DCT (P<0.0001), IOPg and GAT (P<0.002), and IOPg and DCT (P<0.0001), was highly statistically significant. In multivariable regression analysis, DCT IOP and GAT IOP measurements were significantly associated with CH and CRF (P<0.0001 for both). DCT seemed to be affected by CH and CRF, and the IOP values tended to be higher when compared with GAT. ORA-measured IOPcc was found to be independent of CCT and suitable in comparison to the DCT in keratoconic eyes.

  15. Glaucoma Mini-Shunt Implantation After Keratoplasty.

    PubMed

    Ledesma-Gil, Jasbeth; García-Rodríguez, María de Los Ángeles; Gurria, Lulu U; Graue-Hernández, Enrique O; Navas, Alejandro

    2017-04-01

    To report the outcomes of patients who underwent miniature glaucoma shunt implantation after secondary glaucoma due to keratoplasty. Prospective study of consecutive clinical cases who underwent mini-glaucoma shunt implantation following keratoplasty. In brief, a fornix-based conjunctival flap was performed, approximately 50% thickness scleral flap. Mitomycin C 0.025% placed under Tenon's capsule. A 25-G needle created entry for mini-shunt. Ex-PRESS model P-50 was inserted. Scleral flap and conjunctiva were closed with 10-0 Nylon. STATA 8.0 and SPSS software were used for statistical analysis. Seventeen eyes of 17 patients with a mean age of 39.70 years (SD=18.33, range: 18 to 76). A total of 64.70% were male and 35.30% female. Eleven cases after penetrating keratoplasty, 3 cases after triple procedure, 2 after deep anterior lamellar keratoplasty, and 1 following endothelial keratoplasty. Most of the indications for keratoplasty were keratoconus in 9 cases (52.94%), 4 due to endothelial failure (23.52%), 3 cases of herpetic keratitis (17.64%), and 1 case of post-LASIK ectasia (5.88%). Mean preoperative intraocular pressure was 35.94 mm Hg with maximal medical therapy (SD=9.65, range: 18 to 55). Decreasing intraocular pressure to 12.76 mm Hg postoperatively (SD=2.51, range 10 to 18) (P=0.001). Mean follow-up after mini-glaucoma shunt implantation was 23.76 months (SD=8.73, range: 10 to 35 mo). Preoperative mean uncorrected distance visual acuity (UDVA) was 1.31±0.63 (20/408 Snellen) and postoperative mean UDVA was 0.85±0.40 (20/141 Snellen) (P=0.001). Preoperative mean corrected distance visual acuity (CDVA) was 0.83±0.76 (20/135 Snellen) and postoperative mean CDVA was 0.56±0.44 (20/72 Snellen) (P=0.032). Ex-PRESS miniature glaucoma shunt could be an alternative treatment in postkeratoplasty glaucoma resistant to medical treatment. This technique may be helpful, in trying to avoid corneal damage produced by conventional glaucoma procedures.

  16. Quercetin and the ocular surface: What we know and where we are going

    PubMed Central

    McKay, Tina B

    2017-01-01

    Flavonoids are a class of plant and fungus secondary metabolites that serve functional roles in protecting against UV-induced oxidative stress, mediating auxin signaling, and promoting microbial defense. Flavonoids are extremely abundant in nature where their potent antioxidant capacity and very low toxicity makes them highly attractive as potential therapeutic agents. In terms of clinical applications, neither the Food and Drug Administration (FDA) nor the European Food Safety Authority (EFSA) has approved any health claims or drugs related to the use of flavonoids for therapeutic purposes. Quercetin is a common flavonol that has been shown to have potent antioxidant, anti-inflammatory, and anti-fibrotic activities both in vitro and in vivo in various tissues. Recently, the application of quercetin as a therapeutic has been gaining attention in the ocular surface scientific community in the study of dry eye, keratoconus, inflammation, and neovascularization of the cornea. This review will discuss the latest findings and the use of quercetin for the treatment of dystrophies of the ocular surface. Impact statement The eye represents a small portion of the human body, accounting for one decimal fraction of the anterior body surface. The cornea is an avascular, transparent tissue that acts as a primary barrier against mechanical and infectious damaging agents, protecting the internal structures of the eye. Corneal survival and function are affected by a number of factors including but not limited to injury, trauma, infection, genetics, and environment. Corneal injury, or trauma, often leads to loss of corneal transparency and even blindness. The concept of “curing” corneal opacity has been discussed in published form for over 200 years. Currently, full corneal transplant is the only treatment option. There is a strong interest in developing natural therapeutic products that come with minimum side effects. A novel antioxidant flavonoid, quercetin, has been

  17. Agreement Between Autorefraction and Subjective Refraction in Keraring-Implanted Keratoconic Eyes.

    PubMed

    Al-Tuwairqi, Waleed S; Ogbuehi, Kelechi C; Razzouk, Haya; Alanazi, Mana A; Osuagwu, Uchechukwu L

    2017-03-01

    To assess the agreement between subjective refraction and autorefraction and to explore the relationship between the magnitude of higher order aberration, and visual acuity and refraction, before and after keraring implantation. This prospective, randomized, interventional study enrolled 27 subjects (mean age 28.1±6.5 years) with keratoconus. Noncycloplegic refraction was performed subjectively by one clinician and with an autorefractor by another clinician, before and 6 months after surgery. The limit of agreement (LoA) between methods was assessed, and the relationships between the corrected distance visual acuity, logMAR on the one hand and refraction measurements and higher-order aberrations on the other, were examined. The agreement in mean spherical equivalent refraction (MSER) between methods was good postoperatively but poor preoperatively. The autorefractor gave a more myopic refraction than subjective refraction preoperatively (-3.28±3.06 D; LoA -9.27 to +2.71 D, P<0.0001) and postoperatively (-0.63±1.64 D; LoA -3.85 to +2.58 D, P=0.055), and returned higher negative cylinders preoperatively (-1.10±1.17 D; LoA -3.40 to +1.19 D, P<0.0001) and postoperatively (-1.08±1.27 D; LoA -3.60 to +1.41 D, P<0.0001) in keratoconic eyes. The difference in MSER between methods was significantly related to the refractive error at both visits (P<0.05) and to the magnitude of higher-order aberrations in keratoconic eyes preoperatively (P<0.05). The logMAR visual acuity achieved subjectively worsened as the magnitude of higher-order aberrations increased preoperatively (P<0.001). The autorefractor returns values that are significantly more myopic in MSER and higher negative cylinders than subjective refraction, preoperatively, but the MSER was similar between devices postoperatively. The autorefactor seems a valid starting point for subjective refraction in keratoconic eyes treated with keraring, but the cylinder should be corrected by about +1 D. The instruments agree

  18. Quercetin and the ocular surface: What we know and where we are going.

    PubMed

    McKay, Tina B; Karamichos, Dimitrios

    2017-03-01

    Flavonoids are a class of plant and fungus secondary metabolites that serve functional roles in protecting against UV-induced oxidative stress, mediating auxin signaling, and promoting microbial defense. Flavonoids are extremely abundant in nature where their potent antioxidant capacity and very low toxicity makes them highly attractive as potential therapeutic agents. In terms of clinical applications, neither the Food and Drug Administration (FDA) nor the European Food Safety Authority (EFSA) has approved any health claims or drugs related to the use of flavonoids for therapeutic purposes. Quercetin is a common flavonol that has been shown to have potent antioxidant, anti-inflammatory, and anti-fibrotic activities both in vitro and in vivo in various tissues. Recently, the application of quercetin as a therapeutic has been gaining attention in the ocular surface scientific community in the study of dry eye, keratoconus, inflammation, and neovascularization of the cornea. This review will discuss the latest findings and the use of quercetin for the treatment of dystrophies of the ocular surface. Impact statement The eye represents a small portion of the human body, accounting for one decimal fraction of the anterior body surface. The cornea is an avascular, transparent tissue that acts as a primary barrier against mechanical and infectious damaging agents, protecting the internal structures of the eye. Corneal survival and function are affected by a number of factors including but not limited to injury, trauma, infection, genetics, and environment. Corneal injury, or trauma, often leads to loss of corneal transparency and even blindness. The concept of "curing" corneal opacity has been discussed in published form for over 200 years. Currently, full corneal transplant is the only treatment option. There is a strong interest in developing natural therapeutic products that come with minimum side effects. A novel antioxidant flavonoid, quercetin, has been gaining

  19. Clinical characteristics and causes of visual impairment in a low vision clinic in northern Jordan

    PubMed Central

    Bakkar, May M; Alzghoul, Eman A; Haddad, Mera F

    2018-01-01

    Aim The aim of the study was to identify causes of visual impairment among patients attending a low vision clinic in the north of Jordan and to study the relevant demographic characteristics of these patients. Subjects and methods The retrospective study was conducted through a review of clinical records of 135 patients who attended a low vision clinic in Irbid. Clinical characteristics of the patients were collected, including age, gender, primary cause of low vision, best corrected visual acuity, and current prescribed low vision aids. Descriptive statistics analysis using numbers and percentages were calculated to summarize categorical and nominal data. Results A total of 135 patients (61 [45.2%] females and 74 [54.8%] males) were recruited in the study. Mean age ± standard deviation for the study population was 24.53 ± 16.245 years; age range was 5–90 years. Of the study population, 26 patients (19.3%) had mild visual impairment, 61 patients (45.2%) had moderate visual impairment, 27 patients (20.0%) had severe visual impairment, and 21 patients (15.6%) were blind. The leading causes of visual impairment across all age groups were albinism (31.9%) and retinitis pigmentosa (RP) (18.5%). Albinism also accounted for the leading cause of visual impairment among the pediatric age group (0–15 years) while albinism, RP, and keratoconus were the primary causes of visual impairment for older patients. A total of 59 patients (43.7%) were given low vision aids either for near or distance. The only prescribed low vision aids for distances were telescopes. For near, spectacle-type low vision aid was the most commonly prescribed low vision aids. Conclusion Low vision services in Jordan are still very limited. A national strategy programme to increase awareness of low vision services should be implemented, and health care policies should be enforced to cover low vision aids through the national medical insurance. PMID:29662299

  20. Global Survey of Corneal Transplantation and Eye Banking.

    PubMed

    Gain, Philippe; Jullienne, Rémy; He, Zhiguo; Aldossary, Mansour; Acquart, Sophie; Cognasse, Fabrice; Thuret, Gilles

    2016-02-01

    Corneal transplantation restores visual function when visual impairment caused by a corneal disease becomes too severe. It is considered the world's most frequent type of transplantation, but, to our knowledge, there are no exhaustive data allowing measurement of supply and demand, although such data are essential in defining local, national, and global strategies to fight corneal blindness. To describe the worldwide situation of corneal transplantation supply and demand. Data were collected between August 2012 and August 2013 from a systematic review of published literature in parallel with national and international reports on corneal transplantation and eye banking. In a second step, eye bank staff and/or corneal surgeons were interviewed on their local activities. Interviews were performed during international ophthalmology or eye-banking congresses or by telephone or email. Countries' national supply/demand status was classified using a 7-grade system. Data were collected from 148 countries. Corneal transplantation and corneal procurements per capita in each country. In 2012, we identified 184,576 corneal transplants performed in 116 countries. These were procured from 283,530 corneas and stored in 742 eye banks. The top indications were Fuchs dystrophy (39% of all corneal transplants performed), a primary corneal edema mostly affecting elderly individuals; keratoconus (27%), a corneal disease that slowly deforms the cornea in young people; and sequellae of infectious keratitis (20%). The United States, with 199.10-6 corneal transplants per capita, had the highest transplantation rate, followed by Lebanon (122.10-6) and Canada (117.10-6), while the median of the 116 transplanting countries was 19.10-6. Corneas were procured in only 82 countries. Only the United States and Sri Lanka exported large numbers of donor corneas. About 53% of the world's population had no access to corneal transplantation. Our survey globally quantified the considerable shortage of

  1. Characteristics of keratoconic patients at two main eye centres in Palestine: a cross-sectional study.

    PubMed

    Shanti, Yousef; Beshtawi, Ithar; Zyoud, Sa'ed H; Abu-Samra, Ahlam; Abu-Qamar, Areen; Barakat, Reem; Shehada, Reham

    2018-04-16

    Keratoconus (KC) is a multifactorial, degenerative ectatic condition of the cornea. It usually manifests during late adolescence or the early twenties. A painless disease, KC may end with severe visual loss. The prevalence of KC in middle-eastern countries is much higher than in other regions of the world. This may be due to genetic and environmental risk factors and consanguinity. The goal of this study is to explore the demographic profile of Palestinian keratoconic patients. A retrospective study was conducted in two ophthalmology centres (Tertiary Ophthalmic Centre of An-Najah National University Hospital and An-Noor Centre at the Specialized Arab Hospital). All medical charts of keratoconic patients attending both centres over the period from 2009 to 2016 were reviewed. These patients were diagnosed by ophthalmologists depending on history, examination and Pentacam. Severity was determined using the k median index from the Pentacam map. Data analysis was carried out using SPSS Version 22. The medical files of 936 keratoconic eyes of 505 keratoconic patients were reviewed. Their mean age at the time of diagnosis was 23.3 ranging from 8 to 62 years. Approximately 70.1% of them presented after the age of 20 years, and younger age groups were more likely to develop a severe disease stage than older ones (P = 0.001, r = - 0.108). There was a nearly equal distribution of patients between the two sexes (49.5% male, 50.5% female). On initial evaluation, the best-corrected visual acuity (BCVA) was recorded as ≥6/12 in most affected eyes (71.5%). Regarding severity, 62% presented in a mild form, while 9.9% were at a severe stage. About 88.2% presented with bilateralism. Most of the patients in their twenties presented with a mild bilateral form of the disease. This result is compatible with published international reports. It is recommended that the results of this study be considered when establishing a screening program in Palestine. Subsequently

  2. Indications for and outcomes of repeat penetrating keratoplasty, 1989-1995.

    PubMed

    Patel, N P; Kim, T; Rapuano, C J; Cohen, E J; Laibson, P R

    2000-04-01

    To evaluate the indications for and outcomes of repeat penetrating keratoplasty over a 7-year period and compare them to a similar study over the prior 6-year period at the same institution. Retrospective noncomparative case series. Two hundred twenty-three consecutive repeat corneal transplants performed by one of five corneal surgeons between 1989 and 1995 were studied. Reasons for primary and regraft failure, indications for the initial corneal graft, graft clarity, and best-corrected visual acuity were measured on each patient. Between 1989 and 1995, 16% (271 of 1689) of transplants performed by our cornea group were regrafts compared with 9% (165 of 1860) in the period from 1983 to 1988 (P < 0.01). The most common indications for penetrating keratoplasty before regraft were pseudophakic bullous keratopathy (27%, 61 of 223), failed graft (20%, 44 of 223), Fuchs' dystrophy (11%, 24 of 223), aphakic bullous keratopathy (9%, 21 of 223), keratoconus (8%, 17 of 223), and herpes simplex keratitis (6%, 14 of 223). Compared with the prior study period of 1983 to 1988, an increase was revealed in the incidence of failed graft (11% to 20%, P = 0.03), and a decrease was revealed in the incidence of aphakic bullous keratopathy (19% to 9%, P = 0.01). Of the 223 regrafts, 55 (25%) failed during the study period (range, 1 month to 7.5 years; mean 2.1 years). Eleven percent (6 of 55) of regraft failures occurred within 6 months, and 55% (30 of 55) failed within 18 months. Of the 150 regrafts with 2 years follow-up (mean, 3.9 years), 111 (74%) had clear grafts. A best-corrected visual acuity of 20/20 to 20/40 was achieved in 41% (46 of 111), 20/50 to 20/100 in 32% (36 of 111), 20/200 to 20/400 in 21% (23 of 111), and counting fingers to no light perception in 5% (6 of 111). Failed grafts are increasing as an indication for penetrating keratoplasty. Graft clarity and visual acuity results continue to be very good, supporting the use of repeat corneal transplantation.

  3. A review and meta-analysis of corneal cross-linking for post-laser vision correction ectasia.

    PubMed

    Wan, Qi; Wang, Dan; Ye, HongQuan; Tang, Jing; Han, Yu

    2017-09-01

    The aim of this study was to review the safety and stability of cornea cross-linking (CXL) for the treatment of keratectasia after Excimer Laser Refractive Surgery. Eligible studies were identified by systematically searching PubMed, Embase, Web of Science and reference lists. Meta-analysis was performed using Stata 12.1 software. The primary outcome parameters included the changes of corrected distant visual acuity (CDVA), uncorrected visual acuity (UCVA), the maximum keratometry value (Kmax) and minimum keratometry value (Kmin), the surface regularity index (SRI), the surface asymmetry index (SAI), the keratoconus prediction index (KPI), corneal thickness, and endothelial cell count. Efficacy estimates were evaluated by weighted mean difference (WMD) and 95% confidence interval (CI) for absolute changes of the interested outcomes. Seven studies involving 118 patients treated with CXL for progressive ectasia after laser-assisted in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) (140 eyes; the follow-up time range from 12 to 62 months) were included in the meta-analysis. The pooled results showed that there were no significant differences in Kmax and Kmin values after CXL (WMD = 0.584; 95% CI: -0.289 to 1.458; P  = 0.19; WMD = 0.466; 95% CI: -0.625 to 1.556; P  = 0.403, respectively). The CDVA improved significantly after CXL (WMD = 0.045; 95% CI: 0.010 to 0.079; P  = 0.011), whereas UCVA did not differ statistically (WMD = 0.011; 95% CI: -0.055 to 0.077; P  = 0.746). The changes were not statistically significant in SRI, SAI, and KPI (WMD = 0.116; 95% CI: -0.090 to 0.322; P  = 0.269; WMD = 0.240; 95% CI: -0.200 to 0.681; P  = 0.285; WMD = 0.045; 95% CI: -0.001 to 0.090; P  = 0.056, respectively). Endothelial cell count and corneal thickness did not deteriorate (WMD = 12.634; 95% CI: -29.460 to 54.729; P  = 0.556; WMD = 0.657; 95% CI: -9.402 to 10.717; P  = 0.898, respectively). The study showed that CXL is a

  4. Morphometric changes of corneal endothelial cells following intracameral air for micro perforation of the Descemet Membrane during big-bubble deep anterior lamellar keratoplasty.

    PubMed

    Khattak, Ashbala; Nakhli, Fouad R; Abdullatif Abouollo, Hussam Mohammad

    2016-01-01

    The aim of this study was to assess the effect of intracameral air on the endothelial cell morphometrics. This is a retrospective controlled interventional cohort study of 26 patients (18 males and 8 females) who underwent unilateral deep anterior lamellar keratoplasty (DALK) for moderate keratoconus. The DALK patients were divided into two groups: a treatment group (14), which had micro perforations of the Descemet Membrane (DM) intraoperatively and received intracameral air at the end of the surgery; and an independent control group (12), which had no micro perforation and thus no intracameral air was injected. Postoperative best corrected visual acuity (BCVA), sphere, cylinder, spherical equivalent (SEQ), central corneal thickness, and endothelial cell morphometric features consisted of the endothelial cell density (ECD), polymegathism, and pleomorphism were compared between treatment and control groups. The mean BCVA was 0.36 ± 0.36 logMAR in the treatment group and 0.17 ± 0.11 logMAR in the control group (p = 0.081), and the mean corneal thickness was 507.86 ± 62.69 μm in the treatment group and 525.67 ± 37.54 μm in the control group air (p = 0.399). Furthermore, the mean sphere was -5.14 ± 4.17D and -1.02 ± 3.29D, the mean cylinder was -3.16 ± 2.20D and -2.88 ± 1.21D, and the mean SEQ was -6.72 ± 4.66D and -2.46 ± 3.14D and in the treatment and control groups respectively (p = 0.011, 0.693, and 0.013). As to morphometric features, the mean ECD was 2176.76 ± 549.18 cell/mm(2) and 2257.30 ± 436.12 cell/mm(2) in the treatment and control groups respectively (p = 0.686), and the mean pleomorphism 0.48 ± 0.09 and 0.54 ± 0.10 in the treatment and control groups respectively (p = 0.139). In contrast, the mean polymegathism was 0.37 ± 0.06 and 0.31 ± 0.05 in the treatment and control groups respectively (p = 0.009). The presence of air inside the anterior chamber for a short term may not cause further

  5. Preliminary results of neural networks and zernike polynomials for classification of videokeratography maps.

    PubMed

    Carvalho, Luis Alberto

    2005-02-01

    Our main goal in this work was to develop an artificial neural network (NN) that could classify specific types of corneal shapes using Zernike coefficients as input. Other authors have implemented successful NN systems in the past and have demonstrated their efficiency using different parameters. Our claim is that, given the increasing popularity of Zernike polynomials among the eye care community, this may be an interesting choice to add complementing value and precision to existing methods. By using a simple and well-documented corneal surface representation scheme, which relies on corneal elevation information, one can generate simple NN input parameters that are independent of curvature definition and that are also efficient. We have used the Matlab Neural Network Toolbox (MathWorks, Natick, MA) to implement a three-layer feed-forward NN with 15 inputs and 5 outputs. A database from an EyeSys System 2000 (EyeSys Vision, Houston, TX) videokeratograph installed at the Escola Paulista de Medicina-Sao Paulo was used. This database contained an unknown number of corneal types. From this database, two specialists selected 80 corneas that could be clearly classified into five distinct categories: (1) normal, (2) with-the-rule astigmatism, (3) against-the-rule astigmatism, (4) keratoconus, and (5) post-laser-assisted in situ keratomileusis. The corneal height (SAG) information of the 80 data files was fit with the first 15 Vision Science and it Applications (VSIA) standard Zernike coefficients, which were individually used to feed the 15 neurons of the input layer. The five output neurons were associated with the five typical corneal shapes. A group of 40 cases was randomly selected from the larger group of 80 corneas and used as the training set. The NN responses were statistically analyzed in terms of sensitivity [true positive/(true positive + false negative)], specificity [true negative/(true negative + false positive)], and precision [(true positive + true

  6. The Unevenness and Non-orthogonal State of Distribution of Corneal Thickness and the Influence on Correction of Myopic Astigmatism by LASEK.

    PubMed

    Wang, Shulin; Wang, Xin; Liu, Mingna; Wang, Haiying; Li, Jing; Shi, Weiyun

    2015-09-01

    To observe and calculate the unevenness and the non-orthogonal state of distribution of corneal thickness and the relationship between them using Pentacam and to investigate the influence of unevenness and the non-orthogonal state on correction of myopic astigmatism by laser subepithelial keratomileusis (LASEK). 230 eyes with myopic astigmatism treated with LASEK were divided into two groups: 114 eyes as the low astigmatism group (-0.25 to -0.75 DC) and 116 eyes as the midrange-high astigmatism group (-1.00 to -4.50 DC). With the help of the diagram of keratoconus evaluation program of the Pentacam, the D 3.0 and D 6.5 were calculated for the index of distribution of unevenness of the corneal thickness, and the absolute value of the angle between the maximum and minimum progression-index orientation (M 90) for the index of non-orthogonal states. The correction of myopic astigmatism by LASEK was based on standard vector analysis and power vector analysis. The follow-up period was for 3 months. The preoperative M 90 was 22.14° ± 20.87°, D 6.5 was 58.66 ± 21.32 μm, and D 3.0 was 16.11 ± 4.28 μm for the 230 eyes that were tested. The D 6.5 of low astigmatism group (55.62 ± 20.81) μm was significantly lower than that of midrange-high astigmatism group (61.65 ± 21.48) μm (P < 0.05). Of the 230 eyes, the M 90 was positively correlated with D 6.5 (r = 0.37, P < 0.001), and D 6.5 was positively correlated with D 3.0 (r = 0.56, P < 0.001). 3 months postoperatively, the absolute error vector (|EV|) of low astigmatism group (0.46 ± 0.34) was significantly lower than that of midrange-high astigmatism group (0.53 ± 0.29) (P < 0.01). The error of magnitude of low astigmatism group (-0.10 ± 0.31) was significantly lower than that of midrange-high astigmatism group (0.08 ± 0.41) (P < 0.001). The absolute error of angle (|EA|) of low astigmatism group (26.10 ± 27.24) was significantly higher than that of midrange

  7. [Morphological characteristics of cornea in patients with vernal keratoconjunctivitis by in vivo laser scanning confocal microscopy].

    PubMed

    Le, Qi-hua; Hong, Jia-xu; Zhu, Wen-qing; Sun, Xing-huai; Xu, Jian-jiang

    2011-05-01

    corneal neovascular epithelium. Longitudinal or oblique dark striae could be found in the posterior stroma in patients with complicated keratoconus. The density of epithelial cells at central and peripheral cornea in healthy controls were (6033.1 ± 998.7) cells/mm(2) and (6098.4 ± 298.3) cells/mm(2), while that in VKC patients were (5972.2 ± 1148.2) cells/mm(2) and (6178.5 ± 318.9) cells/mm(2) respectively, the differences being no statistical significant between them (t = 1.191, 1.011; P = 0.238, 0.318). However, it's found in VKC patients that cellular density at peripheral cornea was significantly higher than that at central area (t = 2.249, P = 0.03). The density of anterior stromal cells at central and peripheral cornea in healthy controls was (1001.4 ± 125.3) cells/mm(2) and (924.6 ± 201.4) cells/mm(2), while that in VKC patients was (1184.5 ± 115.3) cells/mm(2) and (1101.4 ± 151.1) cells/mm(2), the difference bearing no statistical significance (t = 6.617, 3.439; P = 0.001). The density of posterior stromal cells in normal subjects and VKC patients was (537.7 ± 42.6) cells/mm(2) and (548.7 ± 79.8) cells/mm(2), that of endothelial cells was (2985.7 ± 401.2) cells/mm(2) and (3021.5 ± 383.3) cells/mm(2), respectively, neither difference had statistical significance (t = 0.174, 1.112; P = 0.864, 0.282). Langerhans cell infiltration could be identified in 61.5% (16 cases) VKC patients, which was significantly higher than normal control (2 cases, 7.7%) (χ(2) = 12.49, P = 0.001). Furthermore, much intense Langerhans cells infiltration was found in bulbar form and mix form than tarsal form. (t = 6.617, P = 0.001). The density and diameter of subbasal nerve fiber in VKC patients decreased significantly than those in normal subjects, whereas the tortuosity increased significantly. The morphological changes of cornea in VKC patients mainly involve corneal epithelium, subbasal nerve fiber and anterior stroma. In vivo LSCM is helpful in discriminating the subtypes

  8. Hyaluronidase (Vitrase)--ISTA: hyaluronidase--ISTA pharmaceuticals.

    PubMed

    2003-01-01

    submit a marketing approval application with the European Medical Evaluation Agency (EMEA) in the first half of 2003. A phase II trial in Singapore was being conducted by Visionex. However, in March 2000, ISTA completed the acquisition of Visionex. In its Securities and Exchange Commission (SEC) filing, as at 31 December 2002, ISTA stated that the continued development of Vitrase for diabetic retinopathy will be dependent upon a number of factors including the FDA's evaluation of Vitrase for the treatment of vitreous hemorrhage, the successful completion of any additional clinical trials for the diabetic retinopathy, and the continuing assessment of the market opportunity for this indication compared with other product opportunities that ISTA may be pursuing at the time. ISTA is also developing hyaluronidase products for the treatment of cataracts (Keratase) and keratoconus (Keraform).