Sample records for keratometric corneal astigmatic

  1. Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery.

    PubMed

    Sano, Maki; Hiraoka, Takahiro; Ueno, Yuta; Itagaki, Hideo; Ogami, Tomohiro; Oshika, Tetsuro

    2016-12-01

    To examine the influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery. The study enrolled 64 pseudophakic eyes of 50 patients (71.8 ± 9.9 years old, mean ± standard deviation) who had undergone phacoemulsification with non-toric IOL implantation. Refractive astigmatism was measured using an auto ref-keratometer with a 0.01- diopter (D) scale. Two types of corneal astigmatism were calculated using anterior segment optical coherence tomography; keratometric and total corneal astigmatism. Keratometric astigmatism was obtained based on anterior corneal curvature alone and total corneal astigmatism was calculated using both anterior and posterior corneal curvatures. The difference between refractive and corneal astigmatism was computed as the vector difference using 1) refractive and keratometric astigmatism and 2) refractive and total corneal astigmatism. The mean refractive, keratometric, and total corneal astigmatism was 0.92 ± 0.48 D, 0.87 ± 0.44 D, and 0.94 ± 0.46 D, respectively. The difference between refractive and keratometric astigmatism (0.70 ± 0.40 D, mean vector of 0.30 D axis 164°) was significantly larger than the difference between refractive and total corneal astigmatism (0.63 ± 0.38 D, mean vector of 0.12 D axis 137°) (P = .019). The difference between refractive and total corneal astigmatism, calculated using both anterior and posterior corneal curvatures, was significantly smaller than the difference between refractive and keratometric astigmatism using anterior corneal astigmatism alone, implying that the latter overestimates the true postoperative refractive astigmatism and can cause cylindrical inaccuracy after cataract surgery.

  2. Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

    PubMed

    Eom, Youngsub; Ryu, Dongok; Kim, Dae Wook; Yang, Seul Ki; Song, Jong Suk; Kim, Sug-Whan; Kim, Hyo Myung

    2016-10-01

    To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Two thousand samples of corneal parameters with keratometric astigmatism ≥ 1.0 D were obtained using bootstrap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.

  3. Age-Related Changes in Corneal Astigmatism.

    PubMed

    Shao, Xu; Zhou, Kai-Jing; Pan, An-Peng; Cheng, Xue-Ying; Cai, He-Xie; Huang, Jin-Hai; Yu, A-Yong

    2017-10-01

    To analyze the changes in corneal astigmatism as a function of age and develop a novel model to estimate corneal astigmatic change according to age. This was a cross-sectional study of right eyes of 3,769 individuals. Total corneal astigmatism, keratometric astigmatism, anterior corneal astigmatism, and posterior corneal astigmatism were measured by a Scheimpflug tomographer. Smoothing fitting curves of polar values of corneal astigmatism as a function of age were drawn and average changes in corneal astigmatism at different ages were calculated. Two turning points of age on total corneal astigmatism were 36 and 69 years. The average change of total corneal astigmatism toward against-the-rule astigmatism was 0.13 diopters (D)/10 years from 18 to 35 years, 0.45 D/10 years from 36 to 68 years, and decreased after 69 years, mainly caused by anterior corneal astigmatism. The mean magnitude of posterior corneal astigmatism was -0.33 D and exceeded 0.50 D in 14.27% of eyes. The vectorial difference between total corneal astigmatism and keratometric astigmatism was correlated with posterior corneal astigmatism, polar value of anterior corneal astigmatism, age, and corneal higher order aberrations (r = 0.636; standard partial regression coefficients were 0.479, -0.466, 0.282, and 0.196, respectively; all P < .001). Based on the non-linear model to estimate corneal astigmatic change with age, a formula was developed to calculate recommended correction of astigmatism according to age and astigmatic type. The rate of change of total corneal astigmatism showed a non-linear trend toward against-the-rule astigmatism, which was low at young and old age, high at middle age, and should be taken into account when performing surgery to correct astigmatism. [J Refract Surg. 2017;33(10):696-703.]. Copyright 2017, SLACK Incorporated.

  4. Long-term follow-up of astigmatic keratotomy for corneal astigmatism after penetrating keratoplasty.

    PubMed

    Böhringer, Daniel; Dineva, Nina; Maier, Philip; Birnbaum, Florian; Kirschkamp, Thomas; Reinhard, Thomas; Eberwein, Philipp

    2016-11-01

    To report the long-term stability of paired arcuate corneal keratotomies (AKs) in patients with high regular postpenetrating keratoplasty astigmatism. Retrospective chart review of best-corrected visual acuity, refraction and keratometric values of 41 eyes with AK between 2003 and 2012. Magnitude of median target induced astigmatism vector was 9.2 dioptres (Dpt). We reached a median magnitude of surgically induced astigmatism vector of 9.81 Dpt and a median magnitude of difference vector of 5.5 Dpt. In keratometry, we achieved a net median astigmatism reduction by 3.3 Dpt. The average correction index was 1.14, showing a slight overcorrection. Irregularity of keratometric astigmatism increased by 0.6 Dpt, and spherical equivalent changed by 1.75 Dpt. Monocular best spectacle corrected visual acuity increased from preoperatively 20/63 (0.5 logMAR) to 20/40 (0.3 logMAR) postoperatively. Median gain on the ETDRS chart was two lines. Long-term follow-up showed a median keratometric astigmatic increase by 0.3 Dpt per year. Arcuate corneal keratotomies is a safe and effective method to reduce high regular corneal astigmatism following penetrating keratoplasty but has limited predictability. The long-term follow-up shows an increase of keratometric astigmatism by 0.3 Dpt/year, equalizing the surgical effect after 10 years. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. Longitudinal Change and Stability of Refractive, Keratometric, and Internal Astigmatism in Childhood

    PubMed Central

    Harvey, Erin M.; Miller, Joseph M.; Twelker, J. Daniel; Sherrill, Duane L.

    2015-01-01

    Purpose. To assess longitudinal change in refractive, keratometric, and internal astigmatism in a sample of students from a population with a high prevalence of with-the-rule (WTR) astigmatism and to determine the optical origins of changes in refractive astigmatism. Methods. A retrospective analysis of longitudinal measurements of right eye refractive and keratometric astigmatism in Tohono O'odham Native American children was conducted. Changes in refractive and keratometric astigmatism per year were compared in a younger cohort (n = 1594, 3 to <11 years old) and an older cohort (n = 648, 11 to <19 years old). Data were analyzed in clinical notation (Cyl) and vector notation (J0, J45). Results. On average, refractive astigmatism (means: 1.19 diopters [D] Cyl, +0.54 J0, +0.03 J45) resulted primarily from WTR corneal astigmatism (means: +0.85 J0, −0.02 J45) and against-the-rule (ATR) internal astigmatism (means: −0.31 J0, +0.05 J45). Mean longitudinal changes in astigmatism were statistically significant (younger cohort −0.02 D/y Cyl; older cohort +0.06 D/y Cyl). In the younger cohort, astigmatism decreased with age in low and moderate astigmats (<3.00 D) and increased with age in high astigmats (≥3.00 D). In the older cohort, astigmatism increased with age across all levels of astigmatism. Longitudinal changes in keratometric and internal astigmatism were negatively correlated in both cohorts. Conclusions. Cross-sectional data suggest the presence of a constant ATR contribution from internal astigmatism (0.60 D Cyl) that is close to the 0.50 D ATR constant reported by Javal and others. Highly astigmatic 3- to <11-year-old children and children older than age 11 years show a small (not clinically significant) increase in astigmatism with age. A negative correlation between changes in keratometric astigmatism and internal astigmatism suggests an active compensation that may contribute to the stability of astigmatism in Tohono O'odham children. PMID:25515577

  6. Age-related changes in with-the-rule and oblique corneal astigmatism.

    PubMed

    Naeser, Kristian; Savini, Giacomo; Bregnhøj, Jesper Flethøj

    2018-01-25

    To describe the age-related changes in with-the-rule (WTR) and oblique keratometric astigmatism (KA), posterior corneal astigmatism (PCA) and total corneal astigmatism (TCA). We used a Pentacam HR (high-resolution) rotating Scheimpflug camera to determine the KA, PCA and TCA in the right eyes of 710 patients, aged from 20 to 88 years. The age-related changes along the vertical, horizontal and oblique meridians were analyzed with Naeser's polar value method in a cross-sectional study. In the whole group, all meridional astigmatic powers and polar values were stable in the age groups from 20 to 49 years, followed by a 1.0 dioptre (D) against-the-rule (ATR) change in KA and TCA, and a 0.12 D reduction in against-the-rule PCA. A nasal rotation of the steep meridian in KA and TCA was noted in the 70-88 years old. The PCA averaged approximately 0.25 D ATR in all age groups. Females displayed the same early astigmatic stability as in the whole group, while male eyes demonstrated a linear decay from 1.5 D WTR at 20 years to 0.5 D ATR astigmatism for the oldest patients. Corneal astigmatism is stable until the age of 50 years; thereafter both keratometric and total corneal astigmatism show a 0.25 D ATR change per 10 years. The average 0.25 D ATR PCA compensates the predominant keratometric WTR astigmatism in the younger patients and increases the TCA in the elderly with keratometric ATR astigmatism. The gender-based differences in age-related astigmatism require further studies. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Agreement between total corneal astigmatism calculated by vector summation and total corneal astigmatism measured by ray tracing using Galilei double Scheimpflug analyzer.

    PubMed

    Feizi, Sepehr; Delfazayebaher, Siamak; Ownagh, Vahid; Sadeghpour, Fatemeh

    To evaluate the agreement between total corneal astigmatism calculated by vector summation of anterior and posterior corneal astigmatism (TCA Vec ) and total corneal astigmatism measured by ray tracing (TCA Ray ). This study enrolled a total of 204 right eyes of 204 normal subjects. The eyes were measured using a Galilei double Scheimpflug analyzer. The measured parameters included simulated keratometric astigmatism using the keratometric index, anterior corneal astigmatism using the corneal refractive index, posterior corneal astigmatism, and TCA Ray . TCA Vec was derived by vector summation of the astigmatism on the anterior and posterior corneal surfaces. The magnitudes and axes of TCA Vec and TCA Ray were compared. The Pearson correlation coefficient and Bland-Altman plots were used to assess the relationship and agreement between TCA Vec and TCA Ray , respectively. The mean TCA Vec and TCA Ray magnitudes were 0.76±0.57D and 1.00±0.78D, respectively (P<0.001). The mean axis orientations were 85.12±30.26° and 89.67±36.76°, respectively (P=0.02). Strong correlations were found between the TCA Vec and TCA Ray magnitudes (r=0.96, P<0.001). Moderate associations were observed between the TCA Vec and TCA Ray axes (r=0.75, P<0.001). Bland-Altman plots produced the 95% limits of agreement for the TCA Vec and TCA Ray magnitudes from -0.33 to 0.82D. The 95% limits of agreement between the TCA Vec and TCA Ray axes was -43.0 to 52.1°. The magnitudes and axes of astigmatisms measured by the vector summation and ray tracing methods cannot be used interchangeably. There was a systematic error between the TCA Vec and TCA Ray magnitudes. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  8. Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation.

    PubMed

    Savini, Giacomo; Næser, Kristian; Schiano-Lomoriello, Domenico; Ducoli, Pietro

    2017-09-01

    To compare keratometric astigmatism (KA) and different modalities of measuring total corneal astigmatism (TCA) for toric intraocular lens (IOL) calculation and optimize corneal measurements to eliminate the residual refractive astigmatism. G.B. Bietti Foundation IRCCS, Rome, Italy. Prospective case series. Patients who had a toric IOL were enrolled. Preoperatively, a Scheimpflug camera (Pentacam HR) was used to measure TCA through ray tracing. Different combinations of measurements at a 3.0 mm diameter, centered on the pupil or the corneal vertex and performed along a ring or within it, were compared. Keratometric astigmatism was measured using the same Scheimpflug camera and a corneal topographer (Keratron). Astigmatism was analyzed with Næser's polar value method. The optimized preoperative corneal astigmatism was back-calculated from the postoperative refractive astigmatism. The study comprised 62 patients (64 eyes). With both devices, KA produced an overcorrection of with-the-rule (WTR) astigmatism by 0.6 diopter (D) and an undercorrection of against-the-rule (ATR) astigmatism by 0.3 D. The lowest meridional error in refractive astigmatism was achieved by the TCA pupil/zone measurement in WTR eyes (0.27 D overcorrection) and the TCA apex/zone measurement in ATR eyes (0.07 D undercorrection). In the whole sample, no measurement allowed more than 43.75% of eyes to yield an absolute error in astigmatism magnitude lower than 0.5 D. Optimized astigmatism values increased the percentage of eyes with this error up to 57.81%, with no difference compared with the Barrett calculator and the Abulafia-Koch calculator. Compared with KA, TCA improved calculations for toric IOLs; however, optimization of corneal astigmatism measurements led to more accurate results. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes.

    PubMed

    Feizi, Sepehr; Delfazayebaher, Siamak; Javadi, Mohammad Ali; Karimian, Farid; Ownagh, Vahid; Sadeghpour, Fatemeh

    2018-01-01

    To compare mean posterior corneal power and astigmatism in normal versus keratoconus affected eyes and determine the optimal cut-off points to maximize sensitivity and specificity in discriminating keratoconus from normal corneas. A total of 204 normal eyes and 142 keratoconus affected eyes were enrolled in this prospective comparative study. Mean posterior corneal power and astigmatism were measured using a dual Scheimpflug camera. Correlation coefficients were calculated to assess the relationship between the magnitudes of keratometric and posterior corneal astigmatism in the study groups. Receiver operating characteristic curves were used to compare the sensitivity and specificity of the measured parameters and to identify the optimal cut-off points for discriminating keratoconus from normal corneas. The mean posterior corneal power was -6.29 ± 0.20 D in the normal group and -7.77 ± 0.87 D in the keratoconus group ( P < 0.001). The mean magnitudes of the posterior corneal astigmatisms were -0.32 ± 0.15 D and -0.94 ± 0.39 D in the normal and keratoconus groups, respectively ( P < 0.001). Significant correlations were found between the magnitudes of keratometric and posterior corneal astigmatism in the normal (r=-0.76, P < 0.001) and keratoconus (r=-0.72, P < 0.001) groups. The mean posterior corneal power and astigmatism were highly reliable characteristics that distinguished keratoconus from normal corneas (area under the curve, 0.99 and 0.95, respectively). The optimal cut-off points of mean posterior corneal power and astigmatism were -6.70 D and -0.54 D, respectively. Mean posterior corneal power and astigmatism measured using a Galilei analyzer camera might have potential in diagnosing keratoconus. The cut-off points provided can be used for keratoconus screening.

  10. Influence of Posterior Corneal Astigmatism on Total Corneal Astigmatism in Eyes With Keratoconus.

    PubMed

    Savini, Giacomo; Næser, Kristian; Schiano-Lomoriello, Domenico; Mularoni, Alessandro

    2016-11-01

    To measure posterior corneal astigmatism (PCA) and investigate its influence on total corneal astigmatism (TCA) in eyes with keratoconus. Keratometric astigmatism (KA), PCA, and TCA were investigated by means of a dual Scheimpflug analyzer in patients with keratoconus. Vector analysis was carried out with the Næser polar value method. We enrolled 119 eyes. PCA magnitude averaged 0.77 ± 0.43 diopters (D) and exceeded 0.50, 1.00, and 2.00 D in 73.9%, 21.8%, and 16.8% of eyes, respectively. PCA averaged 0.95 ± 0.48, 0.55 ± 0.28, and 0.70 ± 0.35 D in eyes with with-the-rule (WTR), against-the-rule (ATR), and oblique astigmatism. The steepest posterior meridian was oriented vertically (between 61 and 119 degrees) in 55.5% of eyes, thus generating ATR astigmatism. The difference between the location of the steepest meridian of KA and that of TCA was >10 degrees in 8.4% of eyes. On average, KA overestimated TCA in eyes with WTR astigmatism by 0.16 D and underestimated TCA in eyes with ATR astigmatism by 0.22 D. The PCA power oriented along the steeper anterior corneal meridian averaged -0.83 ± 0.40, -0.40 ± 0.37, and -0.53 ± 0.43 D for WTR, ATR, and obliquely astigmatic eyes, respectively. Linear regression disclosed a statistically significant correlation (P < 0.0001, r = 0.16) between the meridional powers of TCA and PCA. In eyes with keratoconus, PCA displays large, variable values and is correlated to TCA. The influence of PCA on TCA cannot be disregarded when planning astigmatism correction by toric intraocular lenses.

  11. Preoperative corneal astigmatism among adult patients with cataract in Northern Nigeria

    PubMed Central

    Isyaku, Mohammed; Ali, Syed A; Hassan, Sadiq

    2014-01-01

    The prevalence and nature of corneal astigmatism among patients with cataract has not been well-documented in the resident African population. This retrospective study was undertaken to investigate preexisting corneal astigmatism in adult patients with cataract. We analyzed keratometric readings acquired by manual Javal-Schiotz keratometry before surgery between January 1, 2011 and December 31, 2011. There were 3,169 patients (3286 eyes) aged between 16 and 110 years involved with a Male to female ratio of 1.4:1. Mean keratometry in diopters was K1 = 43.99 and K2 = 43.80. Mean corneal astigmatism was 1.16 diopter and a majority (45.92%) of eyes had astigmatism between 1.00 and 1.99 diopters. Two-thirds of the eyes (66.9%) in this study had preoperative corneal astigmatism equal to or above 1.00 diopter. Findings will help local cataract surgeons to estimate the potential demand for toric intraocular lenses. PMID:25494254

  12. Corneal and lenticular components of total astigmatism in a preschool sample.

    PubMed

    Shankar, Sunita; Bobier, William R

    2004-07-01

    To examine the contribution of corneal and lenticular components to total astigmatism in preschool low and high astigmats to determine whether there was any compensation for high astigmatism by the lenticular component. Cycloplegic refractive and keratometric measures using the Retinomax K-Plus (Nikon Inc., Melville, NY) were conducted on 129 children (mean age, 51.1 +/- 8.4 mo) in Oxford County, Canada. We divided the sample into high astigmats (total cylinder > or =1 D; mean, 1.38 +/- 0.43 D; n = 29) and normal astigmats (total cylinder < or =0.75 D; mean, 0.22 +/- 0.20 D; n = 100). Measures of total and corneal cylinder were transposed into J0 and J45 components, where positive and negative J0 values quantified with-the-rule (WTR) and against-the-rule astigmatisms, respectively, and J45 quantified oblique astigmatism. WTR astigmatism was dominant in both the high and normal astigmatic group. J0 and J45 components of corneal astigmatism were highly correlated with total astigmatism in high astigmats, whereas only J0 was significantly correlated with total astigmatism in normal astigmats. Although the magnitude of total and corneal cylinder was significantly greater in high astigmats, overall lenticular cylinder was similar in both groups. However, the Fourier transforms showed high astigmats to have significantly lower lenticular J0 and higher lenticular J45 than the normal astigmats. Astigmatism in 3- to 5-year-old children is primarily corneal. In preschool children, the lens does not vary in response to high amounts of corneal WTR astigmatism, and in fact, it increases the oblique astigmatism component when the corneal component is high. In high astigmats, lenticular astigmatism contributes to both J0 and J45 components, whereas the corneal contribution is primarily J0.

  13. A New Approach for the Calculation of Total Corneal Astigmatism Considering the Magnitude and Orientation of Posterior Corneal Astigmatism and Thickness.

    PubMed

    Piñero, David P; Caballero, María T; Nicolás-Albujer, Juan M; de Fez, Dolores; Camps, Vicent J

    2018-06-01

    To evaluate a new method of calculation of total corneal astigmatism based on Gaussian optics and the power design of a spherocylindrical lens (C) in the healthy eye and to compare it with keratometric (K) and power vector (PV) methods. A total of 92 healthy eyes of 92 patients (age, 17-65 years) were enrolled. Corneal astigmatism was calculated in all cases using K, PV, and our new approach C that considers the contribution of corneal thickness. An evaluation of the interchangeability of our new approach with the other 2 methods was performed using Bland-Altman analysis. Statistically significant differences between methods were found in the magnitude of astigmatism (P < 0.001), with the highest values provided by K. These differences in the magnitude of astigmatism were clinically relevant when K and C were compared [limits of agreement (LoA), -0.40 to 0.62 D), but not for the comparison between PV and C (LoA, -0.03 to 0.01 D). Differences in the axis of astigmatism between methods did not reach statistical significance (P = 0.408). However, they were clinically relevant when comparing K and C (LoA, -5.48 to 15.68 degrees) but not for the comparison between PV and C (LoA, -1.68 to 1.42 degrees). The use of our new approach for the calculation of total corneal astigmatism provides astigmatic results comparable to the PV method, which suggests that the effect of pachymetry on total corneal astigmatism is minimal in healthy eyes.

  14. Relationship between preoperative axis of astigmatism and postoperative astigmatic change after superior scleral incision phacoemulsification.

    PubMed

    Lyhne, N; Hansen, T E; Corydon, L

    1998-07-01

    To evaluate the effect of the preoperative axis of astigmatism on the outcome of corneal astigmatism after sutured 5.2 to 5.7 mm superior incision phacoemulsification. Departments of Opthalmology, Odense and Vejle Hospitals, Denmark. Seventy-three consecutive patients with preoperative corneal astigmatism of 2.0 diopters (D) or less, axial length between 20.0 and 25.5 mm, and no eye disease except cataract were grouped according to preoperative with-the-rule (WTR) or against-the-rule (ATR) astigmatism. The keratometric cylinder, induced keratometric cylinder (subtraction), and induced cylinder (Jaffe) were measured and calculated 10 to 12 months postoperatively. The postoperative keratometric cylinder and induced keratometric cylinder were significantly higher in the ATR group (P < .00001; mean difference [95% confidence limits]: 0.76 D [0.54; 0.98] and 0.69 D [0.46; 0.92], respectively). There was no significant difference between groups in induced cylinder (Jaffe). The estimated differences were significantly in favor of patients with preoperative WTR astigmatism. The findings support using temporal incision in cases with a preoperative ATR axis of astigmatism.

  15. Effect of disagreement between refractive, keratometric, and topographic determination of astigmatic axis on suture removal after penetrating keratoplasty

    PubMed Central

    Sarhan, A; Dua, H.; Beach, M.

    2000-01-01

    BACKGROUND/AIMS—Post-keratoplasty astigmatism can be managed by selective suture removal in the steep axis. Corneal topography, keratometry, and refraction are used to determine the steep axis for suture removal. However, often there is a disagreement between the topographically determined steep axis and sutures to be removed and that determined by keratometry and refraction. The purpose of this study was to evaluate any difference in the effect of suture removal, on visual acuity and astigmatism, in patients where such a disagreement existed.
METHODS—37 cases (from 37 patients) of selective suture removal after penetrating keratoplasty, were included. In the first group "the disagreement group" (n=15) there was disagreement between corneal topography, keratometry, and refraction regarding the axis of astigmatism and sutures to be removed. In the second group "the agreement group" (n=22) there was agreement between corneal topography, keratometry, and refraction in the determination of the astigmatic axis and sutures to be removed. Sutures were removed according to the corneal topography, at least 5 months postoperatively. Vector analysis for change in astigmatism and visual acuity after suture removal was compared between groups.
RESULTS—In the disagreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism after suture removal was 3.45 (SD 2.34), 3.57 (1.63), and 2.83 (1.68) dioptres, respectively. In the agreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism was 5.95 (3.52), 5.37 (3.29), and 4.71 (2.69) dioptres respectively. This difference in the vector corrected change in astigmatism between groups was statistically significant, p values of 0.02, 0.03, and 0.03 respectively. Visual acuity changes were more favourable in the agreement group. Improvement or no change in visual acuity occurred in 90.9% in the agreement group compared

  16. Prevalence of Corneal Astigmatism in an NHS Cataract Surgery Practice in Northern Ireland.

    PubMed

    Curragh, David S; Hassett, Patrick

    2017-01-01

    Post-operative corneal astigmatism following cataract surgery can leave the patient with visual impairment. Correcting it at the time of surgery with a toric intraocular lens (TIOL) can give patients a better final visual outcome. The purpose was to determine the prevalence of corneal astigmatism in a cataract population and assess the demand for TIOL. Keratometric data was collected and analyzed for all patients who attended for routine cataract surgery under the care of a single surgeon based in Altnagelvin Area Hospital, Northern Ireland (NI). All patients were included between January 2008 and December 2014. Data was collected retrospectively for this observational study. There were 2080 consecutive eyes of 1788 patients. The mean corneal astigmatism was 1.09 ± 0.83. Corneal astigmatism was 1.50D or less in 1621 eyes (78%). It was more than 2.00 D in 242 eyes (11.6%), more than 2.50 D in 127 eyes (6.1%), more than 3.00D in 68 eyes (3.27%) and more than 3.50 D in 45 eyes (2.16%). For routine cataract surgery, 41.3% of eyes had more than 1.00 D of corneal astigmatism and 11.6% had more and 2.00D. Females had more astigmatism than males. This shows the potential demand for the TIOL in this population.

  17. An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses.

    PubMed

    Savini, Giacomo; Næser, Kristian

    2015-01-13

    To investigate the influence of posterior corneal astigmatism, surgically-induced corneal astigmatism (SICA), intraocular lens (IOL) orientation, and effective lens position on the refractive outcome of toric IOLs. Five models were prospectively investigated. Keratometric astigmatism and an intended SICA of 0.2 diopters (D) were entered into model 1. Total corneal astigmatism, measured by a rotating Scheimpflug camera, was used instead of keratometric astigmatism in model 2. The mean postoperative SICA, the actual postoperative IOL orientation, and the influence of the effective lens position were added, respectively, into models 3, 4, and 5. Astigmatic data were vectorially described by meridional and torsional powers. A set of equations was developed to describe the error in refractive astigmatism (ERA) as the difference between the postoperative refractive astigmatism and the target refractive astigmatism. We enrolled 40 consecutive eyes. In model 1, ERA calculations revealed significant cylinder overcorrection in with-the-rule (WTR) eyes (meridional power = -0.59 ± 0.34 D, P < 0.0001) and undercorrection in against-the-rule (ATR) eyes (0.32 ± 0.42 D, P = 0.01). When total corneal astigmatism was used instead of keratometric astigmatism (model 2), the ERA meridional power decreased in WTR (-0.13 ± 0.42 D) and ATR (0.07 ± 0.59 D) eyes, both values being not statistically significant. Models 3 to 5 did not lead to significant improvement. Posterior corneal astigmatism exerts the highest influence on the ERA after toric IOL implantation. Basing calculations on total corneal astigmatism rather than keratometric astigmatism improves the prediction of the residual refractive astigmatism. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  18. Comparability and repeatability of different methods of corneal astigmatism assessment.

    PubMed

    Ferreira, Tiago B; Ribeiro, Filomena J

    2018-01-01

    To assess the comparability and repeatability of keratometric and astigmatism values measured by four techniques: Orbscan IIz ® (Bausch and Lomb), Lenstar LS 900 ® (Haag-Streit), Cassini ® (i-Optics), and Total Cassini (anterior + posterior surface), in healthy volunteers. Fifteen healthy volunteers (30 eyes) were assessed by the four techniques. In each eye, three consecutive measures were performed by the same operator. Keratometric and astigmatism values were recorded. The intraclass correlation coefficient (ICC) was used to assess comparability and repeatability. Agreement between measurement techniques was evaluated with Bland-Altman plots. Comparability was high between all measurement techniques for minimum keratometry (K1), maximum keratometry (K2), astigmatism magnitude, and astigmatism axis, with ICC >0.900, except for astigmatism magnitude measured by Cassini compared to Lenstar (ICC =0.798) and Orbscan compared to Lenstar (ICC =0.810). However, there were some differences in the median values of K1 and K2 between measurement techniques, and the Bland-Altman plots showed a wide data spread for all variables, except for astigmatism magnitude measured by Cassini and Total Cassini. For J0 and J45, comparability was only high for J0 between Cassini and Orbscan. Repeatability was also high for all measurement techniques except for K2 (ICC =0.814) and J45 (ICC =0.621) measured by Cassini. All measurement techniques showed high comparability regarding K1, K2, and astigmatism axis. Although posterior corneal surface is known to influence these measurements, comparability was high between Cassini and Total Cassini regarding astigmatism magnitude and axis. However, the wide data spread suggests that none of these devices should be used interchangeably.

  19. Fourier analysis algorithm for the posterior corneal keratometric data: clinical usefulness in keratoconus.

    PubMed

    Sideroudi, Haris; Labiris, Georgios; Georgantzoglou, Kimon; Ntonti, Panagiota; Siganos, Charalambos; Kozobolis, Vassilios

    2017-07-01

    To develop an algorithm for the Fourier analysis of posterior corneal videokeratographic data and to evaluate the derived parameters in the diagnosis of Subclinical Keratoconus (SKC) and Keratoconus (KC). This was a cross-sectional, observational study that took place in the Eye Institute of Thrace, Democritus University, Greece. Eighty eyes formed the KC group, 55 eyes formed the SKC group while 50 normal eyes populated the control group. A self-developed algorithm in visual basic for Microsoft Excel performed a Fourier series harmonic analysis for the posterior corneal sagittal curvature data. The algorithm decomposed the obtained curvatures into a spherical component, regular astigmatism, asymmetry and higher order irregularities for averaged central 4 mm and for each individual ring separately (1, 2, 3 and 4 mm). The obtained values were evaluated for their diagnostic capacity using receiver operating curves (ROC). Logistic regression was attempted for the identification of a combined diagnostic model. Significant differences were detected in regular astigmatism, asymmetry and higher order irregularities among groups. For the SKC group, the parameters with high diagnostic ability (AUC > 90%) were the higher order irregularities, the asymmetry and the regular astigmatism, mainly in the corneal periphery. Higher predictive accuracy was identified using diagnostic models that combined the asymmetry, regular astigmatism and higher order irregularities in averaged 3and 4 mm area (AUC: 98.4%, Sensitivity: 91.7% and Specificity:100%). Fourier decomposition of posterior Keratometric data provides parameters with high accuracy in differentiating SKC from normal corneas and should be included in the prompt diagnosis of KC. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  20. Calculations of actual corneal astigmatism using total corneal refractive power before and after myopic keratorefractive surgery.

    PubMed

    Seo, Kyoung Yul; Yang, Hun; Kim, Wook Kyum; Nam, Sang Min

    2017-01-01

    To calculate actual corneal astigmatism using the total corneal refractive astigmatism for the 4-mm apex zone of the Pentacam (TCRP4astig) and keratometric astigmatism (Kastig) before and after photorefractive keratectomy or laser in situ keratomileusis. Uncomplicated 56 eyes after more than 6 months from the surgery were recruited by chart review. Various corneal astigmatisms were measured using the Pentacam and autokeratometer before and after surgery. Three eyes were excluded and 53 eyes of 38 subjects with with-the-rule astigmatism (WTR) were finally included. The astigmatisms were investigated using polar value analysis. When TCRP4astig was set as an actual astigmatism, the efficacy of arithmetic or coefficient adjustment of Kastig was evaluated using bivariate analysis. The difference between the simulated keratometer astigmatism of the Pentacam (SimKastig) and Kastig was strongly correlated with the difference between TCRP4astig and Kastig. TCRP4astig was different from Kastig in magnitude rather than meridian before and after surgery; the preoperative difference was due to the posterior cornea only; however, the postoperative difference was observed in both anterior and posterior parts. For arithmetic adjustment, 0.28 D and 0.27 D were subtracted from the preoperative and postoperative magnitudes of Kastig, respectively. For coefficient adjustment, the preoperative and postoperative magnitudes of Kastig were multiplied by 0.80 and 0.66, respectively. By arithmetic or coefficient adjustment, the difference between TCRP4astig and adjusted Kastig would be less than 0.75 D in magnitude for 95% of cases. Kastig was successfully adjusted to TCPR4astig before and after myopic keratorefractive surgery in cases of WTR. For use of TCRP4astig directly, SimKastig and Kastig should be matched.

  1. Calculations of actual corneal astigmatism using total corneal refractive power before and after myopic keratorefractive surgery

    PubMed Central

    Seo, Kyoung Yul; Yang, Hun; Kim, Wook Kyum; Nam, Sang Min

    2017-01-01

    Purpose To calculate actual corneal astigmatism using the total corneal refractive astigmatism for the 4-mm apex zone of the Pentacam (TCRP4astig) and keratometric astigmatism (Kastig) before and after photorefractive keratectomy or laser in situ keratomileusis Methods Uncomplicated 56 eyes after more than 6 months from the surgery were recruited by chart review. Various corneal astigmatisms were measured using the Pentacam and autokeratometer before and after surgery. Three eyes were excluded and 53 eyes of 38 subjects with with-the-rule astigmatism (WTR) were finally included. The astigmatisms were investigated using polar value analysis. When TCRP4astig was set as an actual astigmatism, the efficacy of arithmetic or coefficient adjustment of Kastig was evaluated using bivariate analysis. Results The difference between the simulated keratometer astigmatism of the Pentacam (SimKastig) and Kastig was strongly correlated with the difference between TCRP4astig and Kastig. TCRP4astig was different from Kastig in magnitude rather than meridian before and after surgery; the preoperative difference was due to the posterior cornea only; however, the postoperative difference was observed in both anterior and posterior parts. For arithmetic adjustment, 0.28 D and 0.27 D were subtracted from the preoperative and postoperative magnitudes of Kastig, respectively. For coefficient adjustment, the preoperative and postoperative magnitudes of Kastig were multiplied by 0.80 and 0.66, respectively. By arithmetic or coefficient adjustment, the difference between TCRP4astig and adjusted Kastig would be less than 0.75 D in magnitude for 95% of cases. Conclusions Kastig was successfully adjusted to TCPR4astig before and after myopic keratorefractive surgery in cases of WTR. For use of TCRP4astig directly, SimKastig and Kastig should be matched. PMID:28403194

  2. Can Opposite Clear Corneal Incisions Have a Role with Post-laser In Situ Keratomileusis Astigmatism?

    PubMed Central

    El-Awady, Hatem; Ghanem, Asaad A.

    2012-01-01

    Purpose: To evaluate the astigmatic correcting effect of paired opposite clear corneal incisions (OCCIs) on the steep axis in patients with residual astigmatism after laser in situ keratomileusis (LASIK) Materials and Methods: Thirty-one eyes of 24 patients with a mean age of 28.4 years ±2.46 (range, 19-36 years) were recruited for the study. Inclusion criteria included residual astigmatism of ≥1.5 diopter (D) after LASIK with inadequate residual stromal bed thickness that precluded ablation. The cohort was divided into two groups; group I (with astigmatism ranging from -1.5 D to -2.5 D) and group II (with astigmatism > -2.5 D). The steep axis was marked prior to surgery. Paired three-step self-sealing opposite clear corneal incisions were performed 1-mm anterior to the limbus on the steep axis with 3.2-mm keratome for group I and 4.1 mm for group II. Patients were examined 1 day, 1 week, 1 month, 3 months and 6 months, postoperatively. Visual acuity, refraction, keratometry, and corneal topography were evaluated preoperatively and postoperatively. Analysis of the difference between groups was performed with the Student t-test. P<0.05 was considered statistically significant. Results: The mean uncorrected visual acuity (UCVA) improved from 0.35±0.13 (range, 0.1-0.6) to 0.78±0.19 (range, 0.5-1) in group I and from 0.26±0.19 (range, 0.1-0.5) to 0.7±0.18 (range, 0.4-1) in group II. The increase in UCVA was statistically significant in both groups (P=0.001, both cases). The mean preoperative and postoperative keratometric astigmatism in group I was 2.0±0.48 D (range, 1.5-2.5 D) and 0.8±0.37 D (range, 0.1-1.4 D), respectively. The decrease in keratometric astigmatism was highly statistically significant in group II (P=0.001.). Mean surgically induced astigmatic reduction by vector analysis was 1.47±0.85 D and 2.21±0.97 D in groups I and II respectively. There were no incision-related complications. Conclusions: Paired OCCIs were predictable and effective in

  3. Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Keratoconus Eyes after Accelerated Corneal Collagen Crosslinking

    PubMed Central

    Caravaca-Arens, Esteban; de Fez, Dolores; Blanes-Mompó, Francisco J.

    2017-01-01

    Purpose To analyze the errors associated to corneal power calculation using the keratometric approach in keratoconus eyes after accelerated corneal collagen crosslinking (CXL) surgery and to obtain a model for the estimation of an adjusted corneal refractive index (nkadj) minimizing such errors. Methods Potential differences (ΔPc) among keratometric (Pk) and Gaussian corneal power (PcGauss) were simulated. Three algorithms based on the use of nkadj for the estimation of an adjusted keratometric corneal power (Pkadj) were developed. The agreement between Pk(1.3375) (keratometric power using the keratometric index of 1.3375), PcGauss, and Pkadj was evaluated. The validity of the algorithm developed was investigated in 21 keratoconus eyes undergoing accelerated CXL. Results P k(1.3375) overestimated corneal power between 0.3 and 3.2 D in theoretical simulations and between 0.8 and 2.9 D in the clinical study (ΔPc). Three linear equations were defined for nkadj to be used for different ranges of r1c. In the clinical study, differences between Pkadj and PcGauss did not exceed ±0.8 D nk = 1.3375. No statistically significant differences were found between Pkadj and PcGauss (p > 0.05) and Pk(1.3375) and Pkadj (p < 0.001). Conclusions The use of the keratometric approach in keratoconus eyes after accelerated CXL can lead to significant clinical errors. These errors can be minimized with an adjusted keratometric approach. PMID:29201459

  4. Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Keratoconus Eyes after Accelerated Corneal Collagen Crosslinking.

    PubMed

    Piñero, David P; Camps, Vicente J; Caravaca-Arens, Esteban; de Fez, Dolores; Blanes-Mompó, Francisco J

    2017-01-01

    To analyze the errors associated to corneal power calculation using the keratometric approach in keratoconus eyes after accelerated corneal collagen crosslinking (CXL) surgery and to obtain a model for the estimation of an adjusted corneal refractive index ( n k adj ) minimizing such errors. Potential differences (Δ P c ) among keratometric ( P k ) and Gaussian corneal power ( P c Gauss ) were simulated. Three algorithms based on the use of n k adj for the estimation of an adjusted keratometric corneal power ( P k adj ) were developed. The agreement between P k (1.3375) (keratometric power using the keratometric index of 1.3375), P c Gauss , and P k adj was evaluated. The validity of the algorithm developed was investigated in 21 keratoconus eyes undergoing accelerated CXL. P k (1.3375) overestimated corneal power between 0.3 and 3.2 D in theoretical simulations and between 0.8 and 2.9 D in the clinical study (Δ P c ). Three linear equations were defined for n k adj to be used for different ranges of r 1c . In the clinical study, differences between P k adj and P c Gauss did not exceed ±0.8 D n k = 1.3375. No statistically significant differences were found between P k adj and P c Gauss ( p > 0.05) and P k (1.3375) and P k adj ( p < 0.001). The use of the keratometric approach in keratoconus eyes after accelerated CXL can lead to significant clinical errors. These errors can be minimized with an adjusted keratometric approach.

  5. [The relations of corneal, lenticular and total astigmatism].

    PubMed

    Liang, D; Guan, Z; Lin, J

    1995-06-01

    To determine the relations of corneal, lenticular and total astigmatism and the changes of the astigmatism with age. Out-patients with refractive errors were refracted with retinoscope after using cycloplegic drops and measured the radii of anterior corneal curvature. One hundred and ninety-four cases (382 eyes) with refractive errors were studied. Of the eyes 67.9% had regular corneal astigmatism, 68.1% irregular lenticular astigmatism and 60.7% regular total astigmatism, 88.5% of the corneal astigmatism has the same quality as the total astigmatism. The total astigmatism in 46% of the eyes included the summation of corneal and lenticular astigmatism, but in 41.3% of the eyes irregular lenticular astigmatism corrected the regular corneal astigmatism. The astigmatism of cornea, lens and total astigmatism changed from regular to irregular with the increase of age. The linear correlation analysis showed a positive correlation between the power of horizontal corneal refraction and age, and a negative corrlation between the power of vertical corneal refraction and age. The shape of cornea was the major cause of total astigmatism. The influence of lens on the total astigmatism was different. The reasons for the change of the total astigmatism from regular to irregular with the increase of age were the changes of the power of corneal refraction, particularly the increase of the power of horizontal corneal refraction and lenticular irregular astigmatism.

  6. Prevalence of corneal astigmatism before cataract surgery in Western Indian Population.

    PubMed

    Moulick, P S; Kalra, Deepak; Sati, Alok; Gupta, Sandeep; Khan, M A; Singh, Archana

    2018-01-01

    The prevalence and nature of corneal astigmatism among cataract surgery candidates has not been well-documented in Indian population. The purpose of the study is to analyse prevalence and presentation patterns of corneal astigmatism (CA) in cataract surgery candidates. Keratometric values were measured in patients before cataract extraction. Descriptive statistics of CA were analysed including the assessment with age ranges. Mean CA of 223 eyes of 223 patients [mean age 61 ± 10 years (range, 29-90 years)] was 0.88 ± 0.61 (95% CI, 0.80-0.96) with 27.8%, 51.1% and 21.1% having with the rule (WTR), against the rule (ATR) and oblique astigmatism (OBL) respectively. Between 40 and 50 years, ATR exceeds WTR and reaches 100% by 80 years. A trend of less negative CA was seen up to 60 years and then increases up to 90 years. CA was below 0.25 dioptre (D) in 17.5% of eyes, between 0.25 and 1.25 D in 63.7% and ≥1.50 D in 18.8% of eyes. Considering CA < 1.25 D in majority of cataract surgery candidates, it is preferable to perform inexpensive keratorefractive procedures rather expensive toric IOLs, especially in developing world.

  7. Vector Analysis of Corneal Astigmatism After Combined Femtosecond-Assisted Phacoemulsification and Arcuate Keratotomy.

    PubMed

    Chan, Tommy C Y; Cheng, George P M; Wang, Zheng; Tham, Clement C Y; Woo, Victor C P; Jhanji, Vishal

    2015-08-01

    To evaluate the outcomes of femtosecond-assisted arcuate keratotomy combined with cataract surgery in eyes with low to moderate corneal astigmatism. Retrospective, interventional case series. This study included patients who underwent combined femtosecond-assisted phacoemulsification and arcuate keratotomy between March 2013 and August 2013. Keratometric astigmatism was evaluated before and 2 months after the surgery. Vector analysis of the astigmatic changes was performed using the Alpins method. Overall, 54 eyes of 54 patients (18 male and 36 female; mean age, 68.8 ± 11.4 years) were included. The mean preoperative (target-induced astigmatism) and postoperative astigmatism was 1.33 ± 0.57 diopters (D) and 0.87 ± 0.56 D, respectively (P < .001). The magnitude of error (difference between surgically induced and target-induced astigmatism) (-0.13 ± 0.68 D), as well as the correction index (ratio of surgically induced and target-induced astigmatism) (0.86 ± 0.52), demonstrated slight undercorrection. The angle of error was very close to 0, indicating no significant systematic error of misaligned treatment. However, the absolute angle of error showed a less favorable range (17.5 ± 19.2 degrees), suggesting variable factors such as healing or alignment at an individual level. There were no intraoperative or postoperative complications. Combined phacoemulsification with arcuate keratotomy using femtosecond laser appears to be a relatively easy and safe means for management of low to moderate corneal astigmatism in cataract surgery candidates. Misalignment at an individual level can reduce its effectiveness. This issue remains to be elucidated in future studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Measurement of Posterior Corneal Astigmatism by the IOLMaster 700.

    PubMed

    LaHood, Benjamin R; Goggin, Michael

    2018-05-01

    To provide the first description of posterior corneal astigmatism as measured by the IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany) and assess how its characteristics compare to previous measurements from other devices. A total of 1,098 routine IOLMaster 700 biometric measurements were analyzed to provide magnitudes and orientation of steep and flat axes of anterior and posterior corneal astigmatism. Subgroup analysis was conducted to assess correlation of posterior corneal astigmatism characteristics to anterior corneal astigmatism and describe the distribution of posterior corneal astigmatism with age. Mean posterior corneal astigmatism was 0.24 ± 0.15 diopters (D). The steep axis of posterior corneal astigmatism was vertically oriented in 73.32% of measurements. Correlation between the magnitude of anterior and posterior corneal astigmatism was greatest when the steep axis of the anterior corneal astigmatism was oriented vertically (r = 0.68, P < .0001). Vertical orientation of the steep axis of anterior corneal astigmatism became less common as age increased, whereas for posterior corneal astigmatism it remained by far the most common orientation. This first description of posterior corneal astigmatism measurement by the IOLMaster 700 found the average magnitude of posterior corneal astigmatism and proportion of vertical orientation of steep axis was lower than previous estimates. The IOLMaster 700 appears capable of providing enhanced biometric measurement for individualized surgical planning. [J Refract Surg. 2018;34(5):331-336.]. Copyright 2018, SLACK Incorporated.

  9. Effects of chalazia on corneal astigmatism : Large-sized chalazia in middle upper eyelids compress the cornea and induce the corneal astigmatism.

    PubMed

    Jin, Ki Won; Shin, Young Joo; Hyon, Joon Young

    2017-03-31

    A chalazion is a common eyelid disease that causes eye morbidity due to inflammation and cosmetic disfigurement. Corneal topographic changes are important factors in corneal refractive surgery, intraocular lens power calculations for cataract surgery, and visual acuity assessments. However, the effects of chalazia on corneal astigmatism have not been thoroughly investigated. The changes in corneal astigmatism according to chalazion size and location is necessary for better outcome of ocular surgery. The aim of this study is to evaluate changes in corneal astigmatism according to chalazion size and location. In this cross-sectional study, a total of 44 eyes from 33 patients were included in the chalazion group and 70 eyes from 46 patients comprised the control group. Chalazia were classified according to location and size. An autokeratorefractometer (KR8100, Topcon; Japan) and a Galilei™ dual-Scheimpflug analyzer (Ziemer Group; Port, Switzerland) were utilized to evaluate corneal changes. Oblique astigmatism was greater in the chalazion group compared with the control group (p < 0.05). Astigmatism by simulated keratometry (simK), steep K by simK, total root mean square, second order aberration, oblique astigmatism, and vertical astigmatism were significantly greater in the upper eyelid group (p < 0.05). Astigmatism by simK, second order aberration, oblique astigmatism, and vertical astigmatism were significantly greater in the large-sized chalazion group (p < 0.05). Corneal wavefront aberration was the greatest in the upper eyelid chalazion group, whole area group, and large-sized chalazion group (p < 0.05). Large-sized chalazia in the whole upper eyelid should be treated in the early phase because they induced the greatest change in corneal topography. Chalazion should be treated before corneal topography is performed preoperatively and before the diagnosis of corneal diseases.

  10. Clinical validation of an algorithm to correct the error in the keratometric estimation of corneal power in normal eyes.

    PubMed

    Piñero, David P; Camps, Vicente J; Mateo, Verónica; Ruiz-Fortes, Pedro

    2012-08-01

    To validate clinically in a normal healthy population an algorithm to correct the error in the keratometric estimation of corneal power based on the use of a variable keratometric index of refraction (n(k)). Medimar International Hospital (Oftalmar) and University of Alicante, Alicante, Spain. Case series. Corneal power was measured with a Scheimpflug photography-based system (Pentacam software version 1.14r01) in healthy eyes with no previous ocular surgery. In all cases, keratometric corneal power was also estimated using an adjusted value of n(k) that is dependent on the anterior corneal radius (r(1c)) as follows: n(kadj) = -0.0064286 r(1c) +1.37688. Agreement between the Gaussian (P(c)(Gauss)) and adjusted keratometric (P(kadj)) corneal power values was evaluated. The study evaluated 92 eyes (92 patients; age range 15 to 64 years). The mean difference between P(c)(Gauss) and P(kadj) was -0.02 diopter (D) ± 0.22 (SD) (P=.43). A very strong, statistically significant correlation was found between both corneal powers (r = .994, P<.01). The range of agreement between P(c)(Gauss) and P(kadj) was 0.44 D, with limits of agreement of -0.46 and +0.42 D. In addition, a very strong, statistically significant correlation of the difference between P(c)(Gauss) and P(kadj) and the posterior corneal radius was found (r = 0.96, P<.01). The imprecision in the calculation of corneal power using keratometric estimation can be minimized in clinical practice by using a variable keratometric index that depends on the radius of the anterior corneal surface. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Posterior corneal astigmatism in refractive lens exchange surgery.

    PubMed

    Rydström, Elin; Westin, Oscar; Koskela, Timo; Behndig, Anders

    2016-05-01

    To assess the anterior, posterior and total corneal spherical and astigmatic powers in patients undergoing refractive lens exchange (RLE) surgery. In 402 consecutive patients planned for RLE at Koskelas Eye Clinic, Luleå, Sweden, right eye data from pre- and postoperative subjective refraction, preoperative IOLMaster(®) biometry and Pentacam HR(®) measurements were collected. Postoperative Pentacam HR(®) data were collected for 54 of the patients. The spherical and astigmatic powers of the anterior and posterior corneal surfaces and for the total cornea were assessed and compared, and surgically, induced astigmatism was calculated using vector analysis. The spherical power of the anterior corneal surface was 48.18 ± 1.69D with an astigmatic power of 0.83 ± 0.54D. The corresponding values for the posterior surface were -6.05 ± 2,52D and 0.26 ± 0.15D, respectively. The total corneal spherical power calculated with ray tracing was 42.47 ± 2.89D with a 0.72 ± 0.48D astigmatic power, and the corresponding figures obtained by estimating the posterior corneal surface were 43.25 ± 1.51D (p < 0.001) with a 0.75 ± 0.49D astigmatic power (p = 0.003). In eyes with anterior astigmatism with-the-rule, the total corneal astigmatism is overestimated if the posterior corneal surface is estimated; in eyes, with against-the-rule astigmatism it is underestimated. Had the posterior corneal surface been measured in this material, 14.7% of the patients would have received a spheric instead of a toric IOL, or vice versa. Estimating the posterior corneal surface in RLE patients leads to systematic measurement errors that can be reduced by measuring the posterior surface. Such an approach can potentially increase the refractive outcome accuracy in RLE surgery. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Comparison of surgically induced astigmatism between femtosecond laser and manual clear corneal incisions for cataract surgery.

    PubMed

    Diakonis, Vasilios F; Yesilirmak, Nilufer; Cabot, Florence; Kankariya, Vardhaman P; Kounis, George A; Warren, Daniel; Sayed-Ahmed, Ibrahim O; Yoo, Sonia H; Donaldson, Kendall

    2015-10-01

    To assess the surgically induced corneal astigmatism (SIA) introduced by femtosecond laser-assisted clear corneal incisions (CCIs) for cataract extraction and to compare it with the SIA of manually created CCIs. Bascom Palmer Eye Institute, Miller School of Medicine, Miami, Florida, USA. Prospective nonrandomized comparative case series. Eyes received femtosecond laser-assisted CCIs (Group 1) or manual CCIs (Group 2). The surgical plan included 1 primary and 1 secondary port; the sites of the incisions were the same in both groups and were diametrically opposed between the right eye and left eye. The SIA was assessed using the preoperative and 1-month postoperative keratometric values obtained from corneal topography examinations. This study included 72 eyes of 68 patients with a mean age of 69.0 years ± 9.87 (SD) (range 36 to 90 years). Thirty-six eyes received femtosecond laser-assisted CCIs (Group 1) and 36 received manual CCIs (Group 2). The mean preoperative topographic corneal astigmatism was -1.19 ± 0.68 diopters (D) (range 0 to 2.50 D) and -0.92 ± 0.63 D (range 0.10 to 2.45 D) for Group 1 and Group 2, respectively, whereas, 1 month after cataract surgery, it was -1.16 ± 0.63 D (range 0.20 to 2.57 D) and -0.95 ± 0.64 D (range 0.21 to 2.37 D), respectively. Multivariate vector analysis revealed no statistically significant difference between the 2 groups for preoperative astigmatism, postoperative astigmatism, and SIA (P > .05 for all comparisons between Group 1 and Group 2). Femtosecond laser-assisted and manual corneal incisions for cataract surgery did not appear to significantly alter corneal astigmatism, whereas they showed comparable SIA. Drs. Yoo and Donaldson are speakers for and consultants to Alcon Surgical, Inc., and Abbott Medical Optics, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Corneal Astigmatism Stability in Descemet Membrane Endothelial Keratoplasty for Fuchs Corneal Dystrophy.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2016-07-01

    To calculate the magnitude and angle of the shift in corneal astigmatism associated with Descemet membrane endothelial keratoplasty (DMEK) surgery to determine the feasibility of concurrent astigmatism correction at the time of DMEK triple procedures. Retrospective study. Forty-seven eyes that previously underwent the DMEK procedure for Fuchs endothelial corneal dystrophy and that had more than 1.0 diopter (D) of front corneal astigmatism preoperatively were identified. All DMEK surgeries used a clear corneal temporal incision of 3.2 mm. Surgically induced astigmatism (SIA) was evaluated 6 months postsurgery with vector analysis using Scheimpflug image reading. We did not find a difference between pre- and postoperative magnitude of front astigmatism (P = 0.88; paired t test). The magnitude of the SIA front surface was 0.77 ± 0.63 D (range, 0.10-3.14 D). The centroid vector of the SIA front surface was 0.14 at 89.3°. A hyperopic corneal power shift was noted in both the front surface by 0.26 ± 0.74 D (range, 0.45-3.05 D) (P = 0.018; paired t test) and back surface by 0.56 ± 0.55 D (range, 0.25-2.40 D) (P < 0.01; paired t test). DMEK surgery induces minimal amounts of corneal astigmatism that is a with-the-rule shift associated with a temporal clear corneal incision. The stability of these data from preop to postop supports the plausibility of incorporating astigmatism correction with the cautious use of toric intraocular lenses for patients with Fuchs corneal dystrophy and cataract.

  14. Role of Hemidivisional Corneal Topographic Astigmatisms (CorTs) in the Regularization and Reduction of Irregular Astigmatism.

    PubMed

    Alpins, Noel; Ong, James K Y; Stamatelatos, George

    2018-03-01

    To demonstrate how the concept of hemidivisional corneal topographic astigmatism (hemiCorT) enables the planning of hemidivisional corneal treatments to reduce irregularity and overall astigmatism. Whole-of-cornea corneal topographic astigmatism (CorT) is calculated from topography data derived from a corneal topographer or tomographer. The cornea is conceptually divided into 2 hemidivisions along the flat meridian of the CorT. For each hemidivision, hemiCorTs are calculated. The regularization treatment for each hemidivision is the treatment required to target the whole-of-cornea CorT, which is a symmetrical orthogonal corneal astigmatism. The regularization is then combined with astigmatism reduction treatment, which could be a conventional refractive treatment or a vector-planned treatment. For each hemidivision, the combined astigmatic effect of the regularization treatment and reduction treatment can be determined through double-angle vector summation. The 2 hemidivisional treatments together regularize and reduce corneal astigmatism. A theoretical pair of hemidivisional treatments is derived from an actual example of a cornea displaying idiopathic asymmetric nonorthogonal astigmatism. HemiCorTs allow for the design of hemidivisional corneal treatments of asymmetric nonorthogonal astigmatism. Such treatments should be suitable in the routine treatment of commonly occurring irregular astigmatism, while also allowing the spherical refractive error to be treated concurrently.

  15. Topographical analysis of corneal astigmatism in patients with tilted-disc syndrome.

    PubMed

    Bozkurt, Banu; Irkec, Murat; Gedik, Sansal; Orhan, Mehmet; Erdener, Uğur

    2002-07-01

    To evaluate the corneal topography in patients with tilted-disc syndrome to determine the relationship between optic disc dysversion and corneal astigmatism and the pattern of astigmatism in these patients. The study included 23 eyes of the 13 tilted-disc syndrome patients with spheric refractive errors ranging between +1.00 D and -9.00 D (mean -4.00 +/- 3.4 D) and astigmatic errors ranging between -0.50 and -4.50 D (mean -1.95 +/- 0.93 D). Corneal topography was performed by computer-assisted videokeratoscope topographic modelling system 2 (TMS-2) and incidence of corneal astigmatism, corneal topographic patterns, and mean values of the topographic indices were determined. Corneal topographic analysis showed corneal astigmatism in 22 out of 23 patients with tilted discs. Corneal astigmatism was symmetric bow tie pattern in 10 eyes (45.45%), asymmetric bow tie pattern in 11 eyes (50%) and irregular in 1 eye (4.5%). Among the patients with bow tie pattern group (21 eyes), 14 eyes had with-the-rule astigmatism, 1 eye had against-the-rule astigmatism, and 6 eyes had oblique astigmatism. In 18 eyes, astigmatism was corneal, whereas combined corneal and lenticular in 4 eyes and lenticular in 1 eye. In the majority of tilted-disc cases, ocular astigmatism is mainly corneal. Morphogenetic factors in the development of the tilted disc might possibly influence the corneal development in such a way to result in corneal astigmatism.

  16. Age Differences in Axial Length, Corneal Curvature, and Corneal Astigmatism in Marfan Syndrome with Ectopia Lentis

    PubMed Central

    Jing, Qinghe; Tang, Yating; Qian, Dongjin

    2018-01-01

    Purpose To investigate the differences in axial length, corneal curvature, and corneal astigmatism with age in patients with Marfan syndrome (MFS) and ectopia lentis. Methods A retrospective case series study was conducted. MFS patients with ectopia lentis were divided into groups according to age. Axial length, corneal curvature, and corneal astigmatism were measured. Results This study included 114 MFS patients (215 eyes) with a mean age of 19.0 ± 13.9 years. Axial length differed significantly across age groups in MFS patients (P < 0.001), whereas corneal curvature did not (P = 0.767). Corneal astigmatism was statistically significant throughout the MFS cohort (P = 0.009), but no significant difference was found in young MFS patients (P = 0.838). With increasing age, the orientation of the corneal astigmatism changed from with-the-rule astigmatism to against-the-rule or oblique astigmatism (P < 0.001). A linear correlation analysis showed weak correlations between age and axial length for both eyes and with corneal astigmatism for the left eye, but there was no correlation between age and corneal curvature. Conclusions In MFS, axial length varies with age, corneal curvature remains stable, and corneal astigmatism is higher in young patients and tends to shift toward against-the-rule or oblique astigmatism. Therefore, it is important to consider age when diagnosing MFS with ocular biometric data. PMID:29854424

  17. Does blunt ocular trauma induce corneal astigmatism?

    PubMed

    Akinci, Arsen; Ileri, Dilek; Polat, Sibel; Can, Cigdem; Zilelioglu, Orhan

    2007-06-01

    To determine the effect of blunt ocular trauma on refractive astigmatism. Eighty-six eyes of 86 patients with known previous refractive status exposed to blunt ocular trauma were included in the study. Trauma-induced astigmatism (TIA) was calculated using vector analysis. In eyes with TIA, central corneal thickness was assessed by ultrasound pachymetry, and corneal topographies were obtained. Anterior-chamber angles were examined by Goldmann 3-mirror lens to find microhemorrhages, scarring, or recession. Patients were followed up between 8 and 12 months (average, 9.2 months). In 18 eyes (21%), TIA was detected. Six (7%) of these eyes had lenticular astigmatism caused by traumatic lens subluxation. In the remaining 12 eyes (14%), corneal topography showed regular astigmatic patterns, which were symmetrical in 3 eyes and asymmetric in the remaining 9. The etiologic factor was a game marble in 6 eyes and a stone in the remaining 6. The mean central corneal thickness was 535.75 microm (range, 498-570 microm) in these 12 eyes. In 9 of these 12 eyes, recession or scarring in the anterior-chamber angle was detected at 1 edge of the steepest axis. Blunt trauma can induce astigmatism. Hard and small objects are more likely to induce astigmatism.

  18. Combined astigmatic keratotomy and conductive keratoplasty to correct high corneal astigmatism.

    PubMed

    Sy, Mary Ellen; Kovoor, Timmy A; Tannan, Anjali; Choi, Daniel; Deng, Sophie X; Danesh, Jennifer; Hamilton, D Rex

    2015-05-01

    To determine the safety, efficacy, and predictability of combined astigmatic keratotomy (AK) and conductive keratoplasty (CK) for treating high corneal astigmatism. University of California-Los Angeles, Los Angeles, California, USA. Retrospective case series. From January 1, 2004, to December 31, 2009, AK and CK were performed in eyes with corneal astigmatism of 5.0 diopters (D) or more after keratoplasty or trauma. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, spherical equivalent (SE), defocus equivalent, mean astigmatism, efficacy index, and complications were evaluated. In 11 eyes of 11 patients, the mean UDVA improved from 1.54 logMAR ± 0.50 (SD) preoperatively to 0.69 ± 0.62 logMAR 3 months postoperatively (P < .001) and the mean CDVA from 0.55 ± 0.62 logMAR to 0.12 ± 0.11 logMAR (P = .028). The mean SE and mean defocus equivalent decreased from -1.25 ± 5.06 D to 3.13 ± 3.06 D (P = .15) and from 7.98 ± 4.41 D to 6.97 ± 3.73 D (P = .45), respectively; these changes were not statistically significant. The mean absolute astigmatism decreased from 10.25 ± 4.71 D to 4.31 ± 2.34 D (P < .001). The mean absolute orthogonal and mean oblique astigmatism showed a statistically significant decrease. The efficacy index was 0.82. One case of wound gape after AK required suturing. No infectious keratitis, corneal perforation, or graft rejection occurred. Results indicate that combined AK and CK is safe and effective for correcting high corneal astigmatism after surgery or trauma. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Relationship between central and peripheral corneal astigmatism in elderly patients

    NASA Astrophysics Data System (ADS)

    Kawamorita, Takushi; Shimizu, Kimiya; Hoshikawa, Rie; Kamiya, Kazutaka; Shoji, Nobuyuki

    2018-03-01

    Abstract Purpose We investigated the relationship between central and peripheral corneal astigmatism in elderly patients. Methods Seventy-six eyes of 76 elderly subjects (mean age = 72.6 ± 3.0 years) were included in the study. Corneal shape was evaluated using the Pentacam HR (Oculus, Wetzlark, Germany), which is comprised of a rotating Scheimpflug camera and a short-wavelength slit light. The power distribution map was selected and corneal astigmatism was calculated using front K-Readings in zones centered on the pupil. Analyzed zones were 2.0-6.0 mm in diameter. Results Corneal astigmatism decreased as diameter increased, similar to what was observed in eyes with with-the-rule astigmatism and against-the-rule astigmatism (ANOVA, p < 0.01). This effect was more pronounced in eyes with a large central corneal astigmatism (Spearman's rank-correlation coefficient test, r = 0.51, p < 0.01). There was no change as to axis of corneal astigmatism (ANOVA, p = 0.98). Conclusion These results suggest that the relationship between central and peripheral corneal astigmatism should be taken into consideration to optimize vision when astigmatic correction is needed.

  20. [Astigmatism after keratoplasty: influence of orthotopic transplantation].

    PubMed

    Feuerstacke, J; Hellwinkel, O; Naydis, I; Linke, S; Klemm, M

    2014-09-01

    Patients undergoing corneal transplantation often suffer from postoperative reduced vision due to high astigmatism. This retrospective study analyzed the influence of heterotopic or orthotopic transplantation on astigmatism and visual outcome. In this study 373 eyes of 334 patients were analyzed. Group 1 (OT) contained 186 eyes, which underwent orthotopic transplantation (side of recipient and donor corresponded), whereas group 2 (HT) included 187 heterotopic keratoplasties (donor cornea placed in the recipient's contralateral side). After 1, 3, 6, 12 and 24 months the median of keratometric astigmatism, objective astigmatism, topographic astigmatism and best corrected visual acuity (BCVA) were assessed and compared between groups. The long-term results showed no statistically significant differences regarding keratometric and objective astigmatism, whereas topographic astigmatism differed significantly (p = 0.04) after 3 months. We observed a lower astigmatism of 5.7 dpt (range 3.08-7.78 dpt) in group OT than in the group HT with 7.1 dpt (range 3.9-10.7 dpt). No differences were found at the other time points. The BCVA showed a significantly better effect after 1 month (p = 0.01) in the OT group of 0.2 (0.1-0.3) than in HT group of 0.1 (0.05/0.25). In the postoperative course no additional significant dissimilarities were documented. Heterotopic and orthotopic keratoplasty show no significant long-term differences in astigmatism and visual outcom.

  1. New approach for correction of error associated with keratometric estimation of corneal power in keratoconus.

    PubMed

    Camps, Vicente J; Piñero, David P; Caravaca-Arens, Esteban; de Fez, Dolores; Pérez-Cambrodí, Rafael J; Artola, Alberto

    2014-09-01

    The aim of this study was to obtain the exact value of the keratometric index (nkexact) and to clinically validate a variable keratometric index (nkadj) that minimizes this error. The nkexact value was determined by obtaining differences (ΔPc) between keratometric corneal power (Pk) and Gaussian corneal power ((Equation is included in full-text article.)) equal to 0. The nkexact was defined as the value associated with an equivalent difference in the magnitude of ΔPc for extreme values of posterior corneal radius (r2c) for each anterior corneal radius value (r1c). This nkadj was considered for the calculation of the adjusted corneal power (Pkadj). Values of r1c ∈ (4.2, 8.5) mm and r2c ∈ (3.1, 8.2) mm were considered. Differences of True Net Power with (Equation is included in full-text article.), Pkadj, and Pk(1.3375) were calculated in a clinical sample of 44 eyes with keratoconus. nkexact ranged from 1.3153 to 1.3396 and nkadj from 1.3190 to 1.3339 depending on the eye model analyzed. All the nkadj values adjusted perfectly to 8 linear algorithms. Differences between Pkadj and (Equation is included in full-text article.)did not exceed ±0.7 D (Diopter). Clinically, nk = 1.3375 was not valid in any case. Pkadj and True Net Power and Pk(1.3375) and Pkadj were statistically different (P < 0.01), whereas no differences were found between (Equation is included in full-text article.)and Pkadj (P > 0.01). The use of a single value of nk for the calculation of the total corneal power in keratoconus has been shown to be imprecise, leading to inaccuracies in the detection and classification of this corneal condition. Furthermore, our study shows the relevance of corneal thickness in corneal power calculations in keratoconus.

  2. [Value the correction of corneal astigmatism in cataract surgery].

    PubMed

    Wang, J; Cao, Y X

    2018-05-11

    The aim of modern micro-incision phacoemulsification combined with foldable intraocular lens implantation and femtosecond laser-assisted cataract surgery is evolving from a simple pursuit of recuperation to a refractive procedure, which involves the correction of ametropia according to preoperative and postoperative refractive conditions, especially corneal astigmatism, in order to achieve the goal of optimized postoperative uncorrected full range of vision. Nowadays, due attention to the effect of preoperative corneal astigmatism, surgery-induced astigmatism and residual astigmatism after operation is lacked, which affect postoperative visual acuity significantly. There are many effective ways to reduce corneal astigmatism after cataract surgery including selecting appropriate size and location of clear corneal incision, employing astigmatism keratotomy and the implantation of Toric intraocular lenses, which need to be appropriately applied and popularized. At the same time, surgical indications, predictability and safety should also be taken into account. (Chin J Ophthalmol, 2018, 54: 321-323) .

  3. Scleral Shape and Its Correlations With Corneal Astigmatism.

    PubMed

    Consejo, Alejandra; Rozema, Jos J

    2018-03-06

    To assess the correlation between the scleral shape and corneal astigmatism. Twenty-two participants (11 nonastigmatic and 11 astigmatic) aged from 19 to 36 years and with no previous ocular surgeries were included in this study. Three-dimensional (3D) corneoscleral maps from both eyes (44 eyes) were acquired using a corneoscleral topographer (Eye Surface Profiler). Each 3D map was split into 13 concentric annuli, each 0.5-mm wide, starting at 1.0-mm radius from the corneal apex to the scleral periphery at 7.5 mm from the apex. Each ring was fitted to a quadratic function of the radial distance to the apex, to calculate the elevation difference between the raw data and the fitting surface ring. For each ring, the resulting elevation difference between the original and fit data profile was fit to a sum of sine function. Decentration and astigmatic terms obtained from the sinusoidal fit were analyzed and compared between nonastigmatic and astigmatic groups. In astigmatic eyes, corneal and scleral asymmetry are highly correlated, but both appear independent of each other in nonastigmatic eyes. No significant difference between astigmatic and nonastigmatic eyes was found for the decentration term [P > 0.05/N (Bonferroni)], whereas for the astigmatic component, the differences were statistically significant [P < 0.05/N (Bonferroni)]. Corneal and scleral shapes are correlated in astigmatic eyes, which suggests that astigmatism is not restricted to the cornea but should rather be considered a property of the entire eye globe.

  4. Patterned corneal collagen crosslinking for astigmatism: Computational modeling study

    PubMed Central

    Seven, Ibrahim; Roy, Abhijit Sinha; Dupps, William J.

    2014-01-01

    PURPOSE To test the hypothesis that spatially selective corneal stromal stiffening can alter corneal astigmatism and assess the effects of treatment orientation, pattern, and material model complexity in computational models using patient-specific geometries. SETTING Cornea and Refractive Surgery Service, Academic Eye Institute, Cleveland, Ohio, USA. DESIGN Computational modeling study. METHODS Three-dimensional corneal geometries from 10 patients with corneal astigmatism were exported from a clinical tomography system (Pentacam). Corneoscleral finite element models of each eye were generated. Four candidate treatment patterns were simulated, and the effects of treatment orientation and magnitude of stiffening on anterior curvature and aberrations were studied. The effect of material model complexity on simulated outcomes was also assessed. RESULTS Pretreatment anterior corneal astigmatism ranged from 1.22 to 3.92 diopters (D) in a series that included regular and irregular astigmatic patterns. All simulated treatment patterns oriented on the flat axis resulted in mean reductions in corneal astigmatism and depended on the pattern geometry. The linear bow-tie pattern produced a greater mean reduction in astigmatism (1.08 D ± 0.13 [SD]; range 0.74 to 1.23 D) than other patterns tested under an assumed 2-times increase in corneal stiffness, and it had a nonlinear relationship to the degree of stiffening. The mean astigmatic effect did not change significantly with a fiber- or depth-dependent model, but it did affect the coupling ratio. CONCLUSIONS In silico simulations based on patient-specific geometries suggest that clinically significant reductions in astigmatism are possible with patterned collagen crosslinking. Effect magnitude was dependent on patient-specific geometry, effective stiffening pattern, and treatment orientation. PMID:24767795

  5. Refractive and corneal astigmatism in white school children in northern ireland.

    PubMed

    O'Donoghue, Lisa; Rudnicka, Alicja R; McClelland, Julie F; Logan, Nicola S; Owen, Christopher G; Saunders, Kathryn J

    2011-06-08

    To study the prevalence of and relation between refractive and corneal astigmatism in white school children in Northern Ireland and to describe the association between refractive astigmatism and refractive error. Stratified random clustering was used to recruit 1053 white children, 392 aged 6-7 years and 661 aged 12-13 years. Eye examinations included cycloplegic autorefraction and ocular biometric measures of axial length and corneal curvature. The prevalence of refractive astigmatism (≥ 1 DC) did not differ significantly between 6- to 7-year-old children (24%; 95% confidence interval [CI], 19-30) and 12- to 13-year-old children (20%; 95% CI, 14-25). The prevalence of corneal astigmatism (≥ 1 DC) also did not differ significantly between 6- to 7-year-old children (29%; 95% CI, 24-34) and 12- to 13-year-old children (25%; 95% CI, 21-28). While levels of refractive astigmatism and corneal astigmatism were similar, refractive astigmatism was predominantly oblique (76%; 95% CI, 67-85, of 6- to 7-year-olds; 59%; 95% CI, 48-70, of 12- to 13-year-olds), but corneal astigmatism was predominantly with-the-rule (80%; 95% CI, 72-87, of 6- to 7-year-olds; 82%; 95% CI, 74-90, of 12- to 13-year-olds). The prevalence of refractive astigmatism was associated with increasing myopia and hyperopia. This study is the first to provide robust population-based data on the prevalence of astigmatism in white school children in the United Kingdom. The prevalence of refractive astigmatism and corneal astigmatism is stable between 6 and 7 years and 12 and 13 years, although this finding would need to be confirmed by prospective studies. There is a high prevalence of refractive and corneal astigmatism which is associated with ametropia.

  6. Corneal refractive power and eccentricity in the 40- to 64-year-old population of Shahroud, Iran.

    PubMed

    Asgari, Soheila; Hashemi, Hassan; Mehravaran, Shiva; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Jafarzadehpur, Ebrahim; Shariati, Mohammad; Fotouhi, Akbar

    2013-01-01

    To determine the normal corneal curvature, power, and eccentricity in an Iranian population and their determinants. This report is part of a population-based study conducted in 2009. Of the 5190 participants of the study, Pentacam data from 8532 eyes of 4266 people who met the inclusion criteria for this analysis were used. For each eye, we extracted minimum and maximum keratometry readings, the average of the 2 readings (mean-K), the difference between these 2 parameters (keratometric astigmatism), and corneal eccentricity. The average mean-K, keratometric astigmatism, and eccentricity were 43.73 ± 2.47, 0.90 ± 0.93, and 0.27 ± 0.63 diopter, respectively. Mean-K was directly correlated with age; inversely correlated with body mass index, axial length, white-to-white corneal diameter, and anterior chamber depth; increased at higher amounts of myopia; and was higher in women compared with men. Keratometric astigmatism was significantly higher in women, increased at higher amount of refractive error, but showed no association with other variables. Eccentricity was correlated indirectly with age and white-to-white corneal diameter, and directly with axial length. It increased with myopia. Compared with other studies, the mean corneal power and eccentricity values were lower in this Iranian population sample. Our findings may have implications for clinical interventions, especially refractive surgery. Further studies can identify the causes of such differences in the shape and size of the cornea, which may also be attributable to the choice of the measuring device.

  7. Analysis of corneal astigmatism before surgery in Chinese congenital ectopia lentis patients.

    PubMed

    Zhang, Yichi; Jin, Guangming; Young, Charlotte Aimee; Cao, Qianzhong; Lin, Junxiong; Lin, Jianqiang; Wang, Yiyao; Zheng, Danying

    2018-04-26

    Purpose This study aims to describe the characteristics of corneal astigmatism before surgery in congenital ectopia lentis (CEL) patients. Methods This retrospective study reviewed 306 CEL patients from 1st January 2006, to 31st December 2015. One eye was randomly selected from each patient when the patient had bilateral EL. The influence of sex, laterality, and Marfan syndrome on corneal astigmatism in different age subgroups was evaluated and compared. The correlation between age and corneal astigmatism was evaluated. Results Two hundred fifty-two eyes were included in this study. The mean corneal astigmatism of CEL patients was 2.00 ± 1.28 D. There was a statistical difference in corneal astigmatism between CEL eyes with and without Marfan syndrome. However, no statistical difference was found between male and female patients, or between the EL-affected eye and the unaffected eye in monocular EL patients. There was a positive correlation between age and corneal astigmatism in CEL eyes. Conclusions This study suggests that CEL patients' corneal astigmatism is higher in patients with Marfan syndrome, and corneal astigmatism of the CEL eye increases with age. Our results are useful for surgeons to make appropriate incision and intraocular lens (IOL) choices for patients, as well as a useful reference for designs of new IOLs.

  8. Comparison of keratometric values and corneal eccentricity.

    PubMed

    Benes, Pavel; Synek, Svatopluk; Petrová, Sylvie

    2013-04-01

    The aim of this work is to compare the findings of keratometric values and their differences at various refractive errors. The eccentricity of the cornea in the sense compared to the possible influence of refraction of the eye is topographically observed. Groups of myopia, hyperopia and emmetropia (as a control group) are always represented in total 600 eyes. The studied cohort in total of 300 clients enrolled. Autorefraktokeratometer with Placido disc was used to measure the steepest and the flattest meridian to determine the corneal eccentricity. Group I consisted of 100 myopes, 35 men and 65 women, average age 37.3 years. Objective refraction--sphere: -2.9 D, cylinder: -0.88 D. Keratometry in this group is in the steepest meridian 7.62 mm and the flattest meridian is 7.76 mm. The eccentricity was 0.37. Group II consisting of 100 hyperopic subjects, 40 men and 60 women, average age 61.6 years. Objective refraction--sphere: +2.71 D, cylinder: -1.0 D. Keratometric measurement looks as follows: the steepest meridian is 7.67 mm, the flattest meridian then is 7.81 mm. The value of the eccentricity is 0.37. The third group III consists of 100 emetropic subjects, then clients without refractive errors who achieve without corrective aids Vmin = 1.0. This group is composed of 42 men and 58 women, mean age 41.4 years. Objective refraction--sphere: +0.32 D, cylinder: -0.28 D. The steepest meridian is 7.72 mm the flattest meridian then 7.83 mm. The eccentricity is represented by the observed values of 0.36. Keratometry as well as topography are fundamental methods of corneal anterior surface measurement. Their proportions are essential for the proper parameters selection especially in case of contact lenses as one of the possible means intended to correct refractive errors.

  9. A genome-wide association study of corneal astigmatism: The CREAM Consortium.

    PubMed

    Shah, Rupal L; Li, Qing; Zhao, Wanting; Tedja, Milly S; Tideman, J Willem L; Khawaja, Anthony P; Fan, Qiao; Yazar, Seyhan; Williams, Katie M; Verhoeven, Virginie J M; Xie, Jing; Wang, Ya Xing; Hess, Moritz; Nickels, Stefan; Lackner, Karl J; Pärssinen, Olavi; Wedenoja, Juho; Biino, Ginevra; Concas, Maria Pina; Uitterlinden, André; Rivadeneira, Fernando; Jaddoe, Vincent W V; Hysi, Pirro G; Sim, Xueling; Tan, Nicholas; Tham, Yih-Chung; Sensaki, Sonoko; Hofman, Albert; Vingerling, Johannes R; Jonas, Jost B; Mitchell, Paul; Hammond, Christopher J; Höhn, René; Baird, Paul N; Wong, Tien-Yin; Cheng, Chinfsg-Yu; Teo, Yik Ying; Mackey, David A; Williams, Cathy; Saw, Seang-Mei; Klaver, Caroline C W; Guggenheim, Jeremy A; Bailey-Wilson, Joan E

    2018-01-01

    To identify genes and genetic markers associated with corneal astigmatism. A meta-analysis of genome-wide association studies (GWASs) of corneal astigmatism undertaken for 14 European ancestry (n=22,250) and 8 Asian ancestry (n=9,120) cohorts was performed by the Consortium for Refractive Error and Myopia. Cases were defined as having >0.75 diopters of corneal astigmatism. Subsequent gene-based and gene-set analyses of the meta-analyzed results of European ancestry cohorts were performed using VEGAS2 and MAGMA software. Additionally, estimates of single nucleotide polymorphism (SNP)-based heritability for corneal and refractive astigmatism and the spherical equivalent were calculated for Europeans using LD score regression. The meta-analysis of all cohorts identified a genome-wide significant locus near the platelet-derived growth factor receptor alpha ( PDGFRA ) gene: top SNP: rs7673984, odds ratio=1.12 (95% CI:1.08-1.16), p=5.55×10 -9 . No other genome-wide significant loci were identified in the combined analysis or European/Asian ancestry-specific analyses. Gene-based analysis identified three novel candidate genes for corneal astigmatism in Europeans-claudin-7 ( CLDN7 ), acid phosphatase 2, lysosomal ( ACP2 ), and TNF alpha-induced protein 8 like 3 ( TNFAIP8L3 ). In addition to replicating a previously identified genome-wide significant locus for corneal astigmatism near the PDGFRA gene, gene-based analysis identified three novel candidate genes, CLDN7 , ACP2 , and TNFAIP8L3 , that warrant further investigation to understand their role in the pathogenesis of corneal astigmatism. The much lower number of genetic variants and genes demonstrating an association with corneal astigmatism compared to published spherical equivalent GWAS analyses suggest a greater influence of rare genetic variants, non-additive genetic effects, or environmental factors in the development of astigmatism.

  10. A genome-wide association study of corneal astigmatism: The CREAM Consortium

    PubMed Central

    Shah, Rupal L.; Li, Qing; Zhao, Wanting; Tedja, Milly S.; Tideman, J. Willem L.; Khawaja, Anthony P.; Fan, Qiao; Yazar, Seyhan; Williams, Katie M.; Verhoeven, Virginie J.M.; Xie, Jing; Wang, Ya Xing; Hess, Moritz; Nickels, Stefan; Lackner, Karl J.; Pärssinen, Olavi; Wedenoja, Juho; Biino, Ginevra; Concas, Maria Pina; Uitterlinden, André; Rivadeneira, Fernando; Jaddoe, Vincent W.V.; Hysi, Pirro G.; Sim, Xueling; Tan, Nicholas; Tham, Yih-Chung; Sensaki, Sonoko; Hofman, Albert; Vingerling, Johannes R.; Jonas, Jost B.; Mitchell, Paul; Hammond, Christopher J.; Höhn, René; Baird, Paul N.; Wong, Tien-Yin; Cheng, Chinfsg-Yu; Teo, Yik Ying; Mackey, David A.; Williams, Cathy; Saw, Seang-Mei; Klaver, Caroline C.W.; Bailey-Wilson, Joan E.

    2018-01-01

    Purpose To identify genes and genetic markers associated with corneal astigmatism. Methods A meta-analysis of genome-wide association studies (GWASs) of corneal astigmatism undertaken for 14 European ancestry (n=22,250) and 8 Asian ancestry (n=9,120) cohorts was performed by the Consortium for Refractive Error and Myopia. Cases were defined as having >0.75 diopters of corneal astigmatism. Subsequent gene-based and gene-set analyses of the meta-analyzed results of European ancestry cohorts were performed using VEGAS2 and MAGMA software. Additionally, estimates of single nucleotide polymorphism (SNP)-based heritability for corneal and refractive astigmatism and the spherical equivalent were calculated for Europeans using LD score regression. Results The meta-analysis of all cohorts identified a genome-wide significant locus near the platelet-derived growth factor receptor alpha (PDGFRA) gene: top SNP: rs7673984, odds ratio=1.12 (95% CI:1.08–1.16), p=5.55×10−9. No other genome-wide significant loci were identified in the combined analysis or European/Asian ancestry-specific analyses. Gene-based analysis identified three novel candidate genes for corneal astigmatism in Europeans—claudin-7 (CLDN7), acid phosphatase 2, lysosomal (ACP2), and TNF alpha-induced protein 8 like 3 (TNFAIP8L3). Conclusions In addition to replicating a previously identified genome-wide significant locus for corneal astigmatism near the PDGFRA gene, gene-based analysis identified three novel candidate genes, CLDN7, ACP2, and TNFAIP8L3, that warrant further investigation to understand their role in the pathogenesis of corneal astigmatism. The much lower number of genetic variants and genes demonstrating an association with corneal astigmatism compared to published spherical equivalent GWAS analyses suggest a greater influence of rare genetic variants, non-additive genetic effects, or environmental factors in the development of astigmatism. PMID:29422769

  11. The effect of corneal anterior surface eccentricity on astigmatism after cataract surgery.

    PubMed

    Park, Choul Yong; Chuck, Roy S; Channa, Prabjot; Lim, Chi-Yeon; Ahn, Byung-Jin

    2011-01-01

    To evaluate the effect of cornea eccentricity on induced astigmatism after cataract surgery. The study included 125 eyes of 87 patients. Preoperative corneal astigmatism, pachymetry, and eccentricity were measured. During cataract surgery, the location of the main incision (2.8-mm clear corneal) was selected to be either superior, superior-nasal, superior-temporal, nasal, or temporal to decrease the preexisting corneal astigmatism. Aspheric intraocular lenses were implanted. Keratometry and manifest refraction were recorded 6 months after surgery. Astigmatism was calculated using vector subtraction software. Three parameters significantly affected postoperative astigmatism: preoperative amount of corneal astigmatism, eccentricity of anterior cornea, and location of the main incision. The mean surgically induced astigmatism (SIA) was calculated to be: superior = 0.82 diopters (D), superior-nasal = 0.50 D, superior-temporal = 0.63 D, temporal = 0.45 D, and nasal = 0.55 D. Superior incision induced the greatest SIA and temporal incision induced the smallest SIA. The eccentricity of anterior cornea showed significantly positive correlation with the amount of SIA (P < .001). The preoperative corneal cylinder power showed significantly positive correlation with the amount of SIA (P < .001). Postoperative astigmatism was affected by various factors in cataract surgery. The greatest postoperative astigmatism is expected in corneas with high anterior eccentricity, high preoperative corneal astigmatism, and superior location of the main incision. Copyright 2011, SLACK Incorporated.

  12. Characteristics of Posterior Corneal Astigmatism in Different Stages of Keratoconus.

    PubMed

    Aslani, Fereshteh; Khorrami-Nejad, Masoud; Aghazadeh Amiri, Mohammad; Hashemian, Hesam; Askarizadeh, Farshad; Khosravi, Bahram

    2018-01-01

    To evaluate the magnitudes and axis orientation of anterior corneal astigmatism (ACA) and posterior corneal astigmatism (PCA), the ratio of ACA to PCA, and the correlation between ACA and PCA in the different stages of keratoconus (KCN). This retrospective case series comprised 161 eyes of 161 patients with KCN (104 men, 57 women; mean age, 22.35 ± 6.10 years). The participants were divided into four subgroups according to the Amsler-Krumeich classification. A Scheimpflug imaging system was used to measure the magnitude and axis orientation of ACA and PCA. The posterior-anterior corneal astigmatism ratio was also calculated. The results were compared among different subgroups. The average amounts of anterior, posterior, and total corneal astigmatism were 4.08 ± 2.21 diopters (D), 0.86 ± 0.46 D, and 3.50 ± 1.94 D, respectively. With-the-rule, against-the-rule, and oblique astigmatisms of the posterior surface of the cornea were found in 61 eyes (37.9%), 67 eyes (41.6%), and 33 eyes (20.5%), respectively; corresponding figures in the anterior corneal surface were 55 eyes (32.4%), 56 eyes (34.8%), and 50 eyes (31.1%), respectively. A strong correlation ( P ≤ 0.001, r = 0.839) was found between ACA and PCA in the different stages of KCN; the correlation was weaker in eyes with grade 3 ( P ≤ 0.001, r = 0.711) and grade 4 ( P ≤ 0.001, r = 0.717) KCN. The maximum posterior-anterior corneal astigmatism ratio (PCA/ACA, 0.246) was found in patients with stage 1 KCN. Corneal astigmatism in anterior surface was more affected than posterior surface by increasing in the KCN severity, although PCA was more affected than ACA in an early stage of KCN.

  13. The Changes in Corneal Astigmatism after Botulinum Toxin-A Injection in Patients with Blepharospasm

    PubMed Central

    Moon, Nam Ju; Lee, Hyeon Il

    2006-01-01

    To determine if the involuntary contractions of eyelids may have any effects on the development of corneal astigmatism, we performed this prospective study which includes 19 patients with either essential blepharospasm or hemifacial spasm. In hemifacial spasm, the degree of corneal astigmatism was evaluated between two eyes. Then the topographic changes were checked using vector analysis technique before and after passively opening the eyelids. They were also measured before and at 1 and 6 months after the injection of Botulinum toxin. Resultantly, 20 eyes had the with-the-rule (group1) and 9 eyes against-the-rule (group2) astigmatism. In hemifacial spasm, significantly more astigmatism was found at spastic eyes. The corneal topographic changes after passively opening the eyelids showed 10 eyes with the astigmatic shift to the with-the-rule, while the remaining 19 to the against-the-rule. At 1 month after injection of Botulinum toxin, group 1 showed reduced average corneal astigmatism, whereas group 2 showed increased astigmatism. The astigmatic change vector showed significantly more against-the-rule. In the contrary, 6 months after treatment, corneal astigmatism again increased in group 1 and decreased in group 2. So they took on the appearance of pretreatment astigmatic status eventually. Conclusively eyelids may play an important role in corneal curvature. PMID:16479079

  14. Algorithm for correcting the keratometric error in the estimation of the corneal power in eyes with previous myopic laser refractive surgery.

    PubMed

    Camps, Vicente J; Piñero, David P; Mateo, Veronica; Ribera, David; de Fez, Dolores; Blanes-Mompó, Francisco J; Alzamora-Rodríguez, Antonio

    2013-11-01

    To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, -1.00 to -6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (Pc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj = -0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = -0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and Pc was 0.00 D, with limits of agreement of -0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = -0.94, P < 0.01). The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.

  15. Surgically induced astigmatism after phacoemulsification by temporal clear corneal and superior clear corneal approach: a comparison.

    PubMed

    Nikose, Archana Sunil; Saha, Dhrubojyoti; Laddha, Pradnya Mukesh; Patil, Mayuri

    2018-01-01

    Cataract surgery has undergone various advances since it was evolved from ancient couching to the modern phacoemulsification cataract surgery. Surgically induced astigmatism (SIA) remains one of the most common complications. The introduction of sutureless clear corneal incision has gained increasing popularity worldwide because it offers several advantages over the traditional sutured limbal incision and scleral tunnel. A clear corneal incision has the benefit of being bloodless and having an easy approach, but SIA is still a concern. In this study, we evaluated the SIA in clear corneal incisions with temporal approach and superior approach phacoemulsification. Comparisons between the two incisions were done using keratometric readings of preoperative and postoperative refractive status. It was a hospital-based prospective interventional comparative randomized control trial of 261 patients conducted in a rural-based tertiary care center from September 2012 to August 2014. The visual acuity and detailed anterior segment and posterior segment examinations were done and the cataract was graded according to Lens Opacification Classification System II. Patients were divided for phacoemulsification into two groups, group A and group B, who underwent temporal and superior clear corneal approach, respectively. The patients were followed up on day 1, 7, 30, and 90 postoperatively. The parameters recorded were uncorrected visual acuity, best-corrected visual acuity, slit lamp examination, and keratometry. The mean difference of SIA between 30th and 90th day was statistically evaluated using paired t -test, and all the analyses were performed using SPSS 18.0 (SPSS Inc.) software. The mean postoperative SIA in group A was 0.998 D on the 30th day, which reduced to 0.768 D after 90 days, and in group B the SIA after 30 days was 1.651 D, whereas it reduced to 1.293 D after 90 days. Temporal clear corneal incision is evidently better than superior clear corneal incision as far as

  16. Correction of low corneal astigmatism in cataract surgery.

    PubMed

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.

  17. Effect of posterior corneal astigmatism on refractive outcomes after toric intraocular lens implantation.

    PubMed

    Zhang, Lijun; Sy, Mary Ellen; Mai, Harry; Yu, Fei; Hamilton, D Rex

    2015-01-01

    To compare the prediction error after toric intraocular lens (IOL) (Acrysof IQ) implantation using corneal astigmatism measurements obtained with an IOLMaster automated keratometer and a Galilei dual rotating camera Scheimpflug-Placido tomographer. Jules Stein Eye Institute, University of California Los Angeles, Los Angeles, California, USA. Retrospective case series. The predicted residual astigmatism after toric IOL implantation was calculated using preoperative astigmatism values from an automated keratometer and the total corneal power (TCP) determined by ray tracing through the measured anterior and posterior corneal surfaces using dual Scheimpflug-Placido tomography. The prediction error was calculated as the difference between the predicted astigmatism and the manifest astigmatism at least 1 month postoperatively. The calculations included vector analysis. The study evaluated 35 eyes (35 patients). The preoperative corneal posterior astigmatism mean magnitude was 0.33 diopter (D) ± 0.16 (SD) (vector mean 0.23 × 176). Twenty-six eyes (74.3%) had with-the-rule (WTR) posterior astigmatism. The postoperative manifest refractive astigmatism mean magnitude was 0.38 ± 0.18 D (vector mean 0.26 × 171). There was no statistically significant difference in the mean magnitude prediction error between the automated keratometer and TCP techniques. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect against-the-rule (ATR) astigmatism. The TCP technique lacked these biases. The automated keratometer and TCP methods for estimating the magnitude of corneal astigmatism gave similar results. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect ATR astigmatism. Dr. Hamilton has received honoraria for educational lectures from Ziemer Ophthalmic Systems. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published

  18. Assessment of refractive astigmatism and simulated therapeutic refractive surgery strategies in coma-like-aberrations-dominant corneal optics.

    PubMed

    Zhou, Wen; Stojanovic, Aleksandar; Utheim, Tor Paaske

    2016-01-01

    The aim of the study is to raise the awareness of the influence of coma-like higher-order aberrations (HOAs) on power and orientation of refractive astigmatism (RA) and to explore how to account for that influence in the planning of topography-guided refractive surgery in eyes with coma-like-aberrations-dominant corneal optics. Eleven eyes with coma-like-aberrations-dominant corneal optics and with low lenticular astigmatism (LA) were selected for astigmatism analysis and for treatment simulations with topography-guided custom ablation. Vector analysis was used to evaluate the contribution of coma-like corneal HOAs to RA. Two different strategies were used for simulated treatments aiming to regularize irregular corneal optics: With both strategies correction of anterior corneal surface irregularities (corneal HOAs) were intended. Correction of total corneal astigmatism (TCA) and RA was intended as well with strategies 1 and 2, respectively. Axis of discrepant astigmatism (RA minus TCA minus LA) correlated strongly with axis of coma. Vertical coma influenced RA by canceling the effect of the with-the-rule astigmatism and increasing the effect of the against-the-rule astigmatism. After simulated correction of anterior corneal HOAs along with TCA and RA (strategies 1 and 2), only a small amount of anterior corneal astigmatism (ACA) and no TCA remained after strategy 1, while considerable amount of ACA and TCA remained after strategy 2. Coma-like corneal aberrations seem to contribute a considerable astigmatic component to RA in eyes with coma-like-aberrations dominant corneal optics. If topography-guided ablation is programmed to correct the corneal HOAs and RA, the astigmatic component caused by the coma-like corneal HOAs will be treated twice and will result in induced astigmatism. Disregarding RA and treating TCA along with the corneal HOAs is recommended instead.

  19. Compensation of Corneal Oblique Astigmatism by Internal Optics: a Theoretical Analysis

    PubMed Central

    Liu, Tao; Thibos, Larry N.

    2017-01-01

    Purpose Oblique astigmatism is a prominent optical aberration of peripheral vision caused by oblique incidence of rays striking the refracting surfaces of the cornea and crystalline lens. We inquired whether oblique astigmatism from these two sources should be expected, theoretically, to have the same or opposite signs across the visual field at various states of accommodation. Methods Oblique astigmatism was computed across the central visual field for a rotationally-symmetric schematic-eye using optical design software. Accommodative state was varied by altering the apical radius of curvature and separation of the biconvex lens’s two aspheric surfaces in a manner consistent with published biometry. Oblique astigmatism was evaluated separately for the whole eye, the cornea, and the isolated lens over a wide range of surface curvatures and asphericity values associated with the accommodating lens. We also computed internal oblique astigmatism by subtracting corneal oblique astigmatism from whole-eye oblique astigmatism. Results A visual field map of oblique astigmatism for the cornea in the Navarro model follows the classic, textbook description of radially-oriented axes everywhere in the field. Despite large changes in surface properties during accommodation, intrinsic astigmatism of the isolated human lens for collimated light is also radially oriented and nearly independent of accommodation both in theory and in real eyes. However, the magnitude of ocular oblique astigmatism is smaller than that of the cornea alone, indicating partial compensation by the internal optics. This implies internal oblique astigmatism (which includes wavefront propagation from the posterior surface of the cornea to the anterior surface of the lens and intrinsic lens astigmatism) must have tangentially-oriented axes. This non-classical pattern of tangential axes for internal astigmatism was traced to the influence of corneal power on the angles of incidence of rays striking the

  20. Compensation of corneal oblique astigmatism by internal optics: a theoretical analysis.

    PubMed

    Liu, Tao; Thibos, Larry N

    2017-05-01

    Oblique astigmatism is a prominent optical aberration of peripheral vision caused by oblique incidence of rays striking the refracting surfaces of the cornea and crystalline lens. We inquired whether oblique astigmatism from these two sources should be expected, theoretically, to have the same or opposite signs across the visual field at various states of accommodation. Oblique astigmatism was computed across the central visual field for a rotationally-symmetric schematic-eye using optical design software. Accommodative state was varied by altering the apical radius of curvature and separation of the biconvex lens's two aspheric surfaces in a manner consistent with published biometry. Oblique astigmatism was evaluated separately for the whole eye, the cornea, and the isolated lens over a wide range of surface curvatures and asphericity values associated with the accommodating lens. We also computed internal oblique astigmatism by subtracting corneal oblique astigmatism from whole-eye oblique astigmatism. A visual field map of oblique astigmatism for the cornea in the Navarro model follows the classic, textbook description of radially-oriented axes everywhere in the field. Despite large changes in surface properties during accommodation, intrinsic astigmatism of the isolated human lens for collimated light is also radially oriented and nearly independent of accommodation both in theory and in real eyes. However, the magnitude of ocular oblique astigmatism is smaller than that of the cornea alone, indicating partial compensation by the internal optics. This implies internal oblique astigmatism (which includes wavefront propagation from the posterior surface of the cornea to the anterior surface of the lens and intrinsic lens astigmatism) must have tangentially-oriented axes. This non-classical pattern of tangential axes for internal astigmatism was traced to the influence of corneal power on the angles of incidence of rays striking the internal lens. Partial

  1. Corneal Curvature, Astigmatism, and Aberrations in Marfan Syndrome with Lens Subluxation: Evaluation by Pentacam HR System.

    PubMed

    Chen, Jiahui; Jing, Qinghe; Tang, Yating; Qian, Dongjin; Lu, Yi; Jiang, Yongxiang

    2018-03-06

    Marfan syndrome (MFS) is associated with abnormalities of corneal biometric characteristics. We conducted a retrospective case-control study including 55 eyes of the MFS patients with lens subluxation and 53 normal eyes of the control subjects to evaluate the corneal curvature, astigmatism and aberrations using a rotating Scheimpflug camera (Pentacam HR). Compared with the control group, the anterior, posterior, and total corneal curvature were flatter in the MFS group. The anterior and total corneal astigmatism were higher in the MFS patients, whereas the posterior corneal astigmatism was not significantly different between the two groups. Regarding the total corneal aberrations, the root mean square (RMS) aberrations, RMS higher-order aberrations and RMS lower-order aberrations increased, whereas the spherical aberration decreased in the MFS patients. Corneal parameters had potential diagnostic values for MFS patients with lens subluxation and the more reasonable cutoffs were the values of corneal curvature <41.35 D, corneal astigmatism >0.85 D and spherical aberration <0.188 μm. Corneal biometric characteristics of MFS patients with lens subluxation include decreased corneal curvature, higher corneal astigmatism, larger corneal aberrations, and lower spherical aberration. Corneal curvature, corneal astigmatism, and spherical aberration are better diagnostic tools for suspicious MFS.

  2. Correction of low corneal astigmatism in cataract surgery

    PubMed Central

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    AIM To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. METHODS A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. RESULTS The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. CONCLUSION The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision. PMID:26309869

  3. Post-keratoplasty astigmatism management by relaxing incisions: a systematic review.

    PubMed

    Ho Wang Yin, Gaëlle; Hoffart, Louis

    2017-01-01

    Postoperative visual acuity can be limited by post-keratoplasty astigmatism, even with a clear corneal graft. Astigmatism management can be performed by selective suture removal, adjustment of sutures, optical correction, photorefractive procedures, wedge resection, intra-ocular lens implantation, intracorneal ring segments, relaxing incisions with or without compression sutures and repeated keratoplasty. Relaxing incisions can be made in the graft, graft-host interface or host cornea. Despite the unpredictability of the method because the flat and steep meridians are usually not orthogonal after penetrating keratoplasty, with asymmetric power distribution, all the studies showed an overall reduction of refractive, keratometric or topographic astigmatism, ranging from 30% to 72% with manual or femtosecond-assisted techniques. Most patients with astigmatism higher than 6 diopters had residual cylinder less than or equal to 3 diopters, which can be treated by laser excimer ablation or secondary intraocular lens implantation.

  4. Lenticular astigmatism in tilted disc syndrome.

    PubMed

    Gündüz, Abuzer; Evereklioglu, Cem; Er, Hamdi; Hepşen, Ibrahim F

    2002-10-01

    To evaluate whether an abnormal optic disc shape in patients with tilted disc syndrome (TDS) is associated with an abnormal configuration of the crystalline lens measured as lenticular astigmatism. Department of Ophthalmology, Inönü University Medical Faculty, Turgut Ozal Medical Center, Malatya, Turkey. This cross-sectional masked case-control study comprised 32 eyes of 32 patients with established TDS (13 men, 19 women; mean age 21.31 years +/- 7.05 [SD]) and 20 age- and sex-matched healthy control subjects (8 men, 12 women; mean age 22.65 +/- 7.11 years) with a comparable amount of myopic astigmatism (spherical equivalent) without TDS. The optic disc was morphometrically analyzed by planimetric evaluation of optic disc photographs. The total refractive and keratometric corneal astigmatism was obtained, and lenticular astigmatism was calculated by vector analysis. The Mann-Whitney U test was used for statistical analysis; 1 eye of each patient was evaluated in both groups. A P value less than 0.05 was considered statistically significant. The mean spherical equivalent refraction was comparable in TDS patients (-4.73 +/- 1.12 diopters [D]) and controls (-4.28 +/- 1.29 D) (P =.210). The mean total astigmatism was higher in TDS patients (-2.96 +/- 1.04 D) than in the controls (-2.51 +/- 1.09 D), but the difference was not significant (P =.151). The mean corneal astigmatism was comparable in TDS patients (-2.07 +/- 0.83 D) and controls (-2.28 +/- 0.87 D) (P =.454), but the calculated mean lenticular astigmatism was significantly higher in TDS patients (-1.31 +/- 0.98 D and -0.20 +/- 0.35 D, respectively) (P <.001). Twenty-nine of 32 TDS patients (90.6%) had lenticular astigmatism; in 16 (50%), it was greater than -1.00 D. Lenticular astigmatism was present in 7 controls (35%); in 2 (10%), it was greater than -1.00 D. The mean keratometry was significantly higher in TDS patients (43.84 +/- 1.06 D) than in the controls (42.75 +/- 1.45 D) (P =.011). Clinically

  5. Analysis of components of total astigmatism in infants and young children.

    PubMed

    Sayed, Khulood Muhammad

    2017-02-01

    The aim of this study is to examine and analyze the contribution of corneal and lenticular components of total astigmatism (TA) in infants and young children and to determine whether there is any compensation for astigmatism by the lenticular component or not. The study was conducted on 614 eyes of 307 infants and young children. Cycloplegic refraction and keratometric measures using the Hand-held Autokeratometer (Nidek Co. Ltd., Hiroishi, Japan) were done for the study group under general anesthesia in Paediatric Ophthalmology Center, Sohag City, Egypt. We divided the sample into high astigmats (total cylinder ≥ 1.00 D; mean, 1.99 ± 0.89 D; n = 431 eyes; 70 %) and normal astigmats (total cylinder ≤ 0.75 D; mean, 0.55 ± 0.22 D; n = 183; 30 %). The prevalence of corneal astigmatism (CA) ≥ 1.00 D was (73 %), any degree of lenticular astigmatism (LA) was (85 %), (LA > 0.25 D = 72 %) TA was predominantly with the rule (n = 499 eyes, 81 %). Eyes with against the rule astigmatism were (n = 33 eyes, 5.3 %) and eyes with oblique astigmatism were (n = 82 eyes; 13.3 %). Gender or age differences in TA, CA, LA, or type of astigmatism were not significant. The prevalence of astigmatism found in this population of newlyborn infants and young children was relatively high, primarily corneal, and WTR astigmatism with high prevalence of oblique astigmatism. LA was much less than previous reports (mean = -0.0044 D), associated with more hyperopic eyes and eyes with high TA. The data suggest that a compensatory process exists between CA and LA to decrease the amount of TA.

  6. LASIK and PRK in hyperopic astigmatic eyes: is early retreatment advisable?

    PubMed

    Frings, Andreas; Richard, Gisbert; Steinberg, Johannes; Druchkiv, Vasyl; Linke, Stephan Johannes; Katz, Toam

    2016-01-01

    To analyze the refractive and keratometric stability in hyperopic astigmatic laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) during the first 6 months after surgery. This retrospective cross-sectional study included 97 hyperopic eyes; 55 were treated with LASIK and 42 with PRK. Excimer ablation for all eyes was performed using the ALLEGRETTO excimer laser platform using a mitomycin C for PRK and a mechanical microkeratome for LASIK. Keratometric and refractive data were analyzed during three consecutive follow-up intervals (6 weeks, 3 months, and 6 months). The corneal topography was obtained using Scheimpflug topography, and subjective refractions were acquired by expert optometrists according to a standardized protocol. After 3 months, mean keratometry and spherical equivalent were stable after LASIK, whereas PRK-treated eyes presented statistically significant (P<0.001) regression of hyperopia. In eleven cases, hyperopic regression of >1 D occurred. The optical zone diameter did not correlate with the development of regression. After corneal laser refractive surgery, keratometric changes are followed by refractive changes and they occur up to 6 months after LASIK and for at least 6 months after PRK, and therefore, caution should be applied when retreatment is planned during the 1st year after surgery because hyperopic refractive regression can lead to suboptimal visual outcome. Keratometric and refractive stability is earlier achieved after LASIK, and therefore, retreatment may be independent of late regression.

  7. Prevalence of Corneal Astigmatism in Tohono O'odham Native American Children 6 Months to 8 Years of Age

    PubMed Central

    Dobson, Velma; Miller, Joseph M.; Schwiegerling, Jim; Clifford-Donaldson, Candice E.; Green, Tina K.; Messer, Dawn H.

    2011-01-01

    Purpose. To describe the prevalence of corneal astigmatism in infants and young children who are members of a Native American tribe with a high prevalence of refractive astigmatism. Methods. The prevalence of corneal astigmatism was assessed by obtaining infant keratometer (IK4) measurements from 1235 Tohono O'odham children, aged 6 months to 8 years. Results. The prevalence of corneal astigmatism >2.00 D was lower in the 1- to <2-year-old age group when compared with all other age groups, except the 6- to <7-year-old group. The magnitude of mean corneal astigmatism was significantly lower in the 1- to <2-year age group than in the 5- to <6-, 6- to <7-, and 7- to <8-year age groups. Corneal astigmatism was with-the-rule (WTR) in 91.4% of astigmatic children (≥1.00 D). Conclusions. The prevalence and mean amount of corneal astigmatism were higher than reported in non–Native American populations. Mean astigmatism increased from 1.43 D in 1-year-olds to nearly 2.00 D by school age. PMID:21460261

  8. Changes in corneal astigmatism during 20 years after cataract surgery.

    PubMed

    Hayashi, Ken; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2017-05-01

    To examine how corneal astigmatism changes with age over 20 years after cataract surgery and to assess whether the changes differ from those in eyes that did not have surgery. Hayashi Eye Hospital, Fukuoka, Japan. Retrospective case study. Using an autokeratometer, corneal astigmatism was measured preoperatively, at baseline (the day the surgically induced astigmatism stabilized), and 10 years and 20 years after baseline. The change in corneal astigmatism between baseline and 10 years, 10 years and 20 years, and baseline and 20 years was determined using power vector analysis and compared between the time intervals and between groups. The study assessed 74 eyes that had phacoemulsification with a horizontal scleral incision more than 21 years ago (surgery group) and 68 eyes that did not have surgery (no-surgery group). The mean vertical/horizontal change in corneal astigmatism (J0) between baseline and 20 years was -0.64 diopter (D) in the surgery group and -0.49 D in the no-surgery group. The oblique change (J45) was -0.03 D in the surgery group and 0.07 D in the no-surgery group. Using multivariate comparison, the mean J0 and J45 values were not significantly different between baseline and 10 years or between 10 years and 20 years in both groups (P ≥ .2350). The J0 and J45 values were not significantly different between the 2 groups at any time interval (P ≥ .1331). Corneal astigmatism continues to change toward against-the-rule astigmatism over 20 years after cataract surgery. This change was similar in eyes that did not have surgery. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. [Comparison of keratometric values and corneal eccentricity of myopia, hyperopia and emmetropia].

    PubMed

    Benes, P; Synek, S; Petrová, S

    2011-01-01

    The aim of this work is to compare the findings of keratometric values and their differences at various ametropias. The eccentricity of the cornea in the sense compared to the possible influence of refraction of the eye is topographically observed. Groups of myopia, hyperopia and emmetropia are always represented 100 subjects, i.e. 600 eyes. The results of these measurements are mutually compared and statistically processed. The studied cohort a total of 300 clients enrolled. To measure the steepest (r1) and flattest meridian (r2) and to determine corneal eccentricity was used autorefraktokeratometer with Placido disc (KR 8100P, Topcon, Japan). The obtained data were processed with appropriate software and statistically evaluated. Group A consisted of 100 myopes (n = 200), 35 men and 65 women, average age 37.3 +/- 18.7 years (min. 10 years, max. 87 years). Objective refractive error - sphere: - 2.9 +/- 2.27 D (min.-0.25 D, -14.5 D max), cylinder: -0.88 +/- 0.75 D (min. -0.25 D, up to -5.0 D). Keratametry in this group is as follows: radius of curvature of the cornea in the front area of the steepest meridian 7.62 +/- 0.28 mm (min. 6.96 mm, max. 8.44 mm) and the flattest meridian is 7.76 +/- 0.3 mm (min. 7.08 mm, max 8.75 mm). The mean eccentricity was 0.37 +/- 0.12 (min 0.00, max. 0.79). Group B consisting of 100 hyperopic subjects (n = 200), 40 men and 60 women, average age 61.6 +/- 15 years (min. 21 years, max 88 years). Objective refraction in this group -sphere: +2.71 +/- 1.6 D (at least +0.25 D, up to +9.0 D), cylinder: -1.0 +/- 0.9 D (min. -0.25 D, max. -5.75 D).Corneal surface curvature in two main sections according keratometric measurement looks as follows: the steepest meridian is 7.67 +/- 0.29 mm (min. 6.99 mm, max. 8.62 mm), the flattest meridian then 7.81 +/- 0.29 mm (min. 7.10 mm, max. 8.70 mm). The value of the median eccentricity for these hundred hyperopes is 0.37 +/- 0.14 (min. 0.00; max 0.86). The third group C consists of 100 emetropic subjects

  10. Pseudolentogenic astigmatic effect of multifocal intraocular lenses: non-corneal ocular residual astigmatism (N-CORA) as a new parameter in astigmatic change analysis.

    PubMed

    Frings, Andreas; Steinberg, Johannes; Druchkiv, Vasyl; Linke, Stephan J; Katz, Toam

    2017-08-01

    This study was initiated to introduce the term non-corneal ocular residual astigmatism (N-CORA) as a new parameter in astigmatic change analysis after implantation of two different types of non-toric, multifocal intraocular lenses (MIOL). Seventy-two eyes from 72 consecutive patients after MIOL surgery were studied in terms of a retrospective, cross-sectional data analysis. Two types of spherical MIOL were used. Surgical technique in all patients was a 2.4-mm incision phacoemulsification, performed by one surgeon. To investigate the magnitude and axis of astigmatic changes, the true corneal astigmatism and Alpins vector method were applied. There were no statistically significant between-group differences related to the preoperative refraction or ocular residual astigmatism (ORA). After surgery, the mean refractive surgically induced astigmatism (RSIA) and the topographic SIA (TSIA) did not differ significantly between the lenses. The magnitude and orientation of ORA and N-CORA changed after surgery. There are no statistically significant differences in postoperative ORA in magnitude or axis when implanting different types of MIOL. The similarity of N-CORA between both MIOL types shows that both diffractive and refractive asymmetric MIOLs with plate haptics have the same pseudolentogenic astigmatic effect which could be presented in terms of the newly introduced parameter N-CORA.

  11. Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China.

    PubMed

    Yu, Ji-Guo; Zhong, Jie; Mei, Zhong-Ming; Zhao, Fang; Tao, Na; Xiang, Yi

    2017-04-26

    To evaluate the distribution of biometric parameters and corneal astigmatism using the IOLMaster device before phacoemulsification in cataract patients in Central China. Consecutive cataract patients were recruited at the Central Hospital of Wuhan between January 2015 and June 2016. Ocular axial length (AL), keratometry values, anterior chamber depth (ACD) and horizontal corneal diameter (white to white [WTW]) of each cataract-affected eye were measured with the IOLMaster device. The study evaluated 3209 eyes of 2821 cataract patients. The mean AL, ACD, and WTW were 24.38 ± 2.47 mm, 3.15 ± 0.48 mm, and 11.63 ± 0.43 mm, respectively. Corneal astigmatism of 0.51-1.00 diopters (D) was the most common range of values (34.96%). A total of 10.56% patients exhibited a corneal astigmatism greater than 2.0 D. The flat and steep keratometry values gradually increased with age. The mean ACD and WTW showed increasing trends as the AL increased (P < 0.001). When the AL was shorter than 26.0 mm, the keratometry decreased as AL increased. The against-the-rule (ATR) astigmatism proportion increased with age and the with-the-rule (WTR) astigmatism proportion decreased with age. The profile of ocular biometric data and corneal astigmatism may help ophthalmologists improve their surgical procedures and make an appropriate IOL choice to gain a high quality of postoperative vision.

  12. Keratometric alterations following the 25-gauge transconjunctival sutureless pars plana vitrectomy versus the conventional pars plana vitrectomy.

    PubMed

    Citirik, Mehmet; Batman, Cosar; Bicer, Tolga; Zilelioglu, Orhan

    2009-09-01

    To assess the alterations in keratometric astigmatism following the 25-gauge transconjunctival sutureless pars plana vitrectomy versus the conventional pars plana vitrectomy. Sixteen consecutive patients were enrolled into the study. Conventional vitrectomy was applied to eight of the cases and 25-gauge transconjunctival sutureless vitrectomy was performed in eight patients. Keratometry was performed before and after the surgery. In the 25-gauge transconjunctival sutureless pars plana vitrectomy group, statistically significant changes were not observed in the corneal curvature in any post-operative follow-up measurement (p > 0.05); whereas in the conventional pars plana vitrectomy group, statistically significant changes were observed in the first postoperative day (p = 0.01) and first postoperative month (p = 0.03). We noted that these changes returned to baseline in three months (p = 0.26). Both 25-gauge transconjunctival sutureless and conventional pars plana vitrectomy are effective surgical modalities for selected diseases of the posterior segment. Surgical procedures are critical for the visual rehabilitation of the patients. The post-operative corneal astigmatism of the vitrectomised eyes can be accurately determined at least two months post-operatively.

  13. Effect of steepest-meridian clear corneal incision for reducing preexisting corneal astigmatism using a meridian-marking method or surgeon's intuition.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Yoshimura, Koichi

    2014-12-01

    To compare the effect of steepest-meridian clear corneal incisions (CCIs) for reducing preexisting corneal astigmatism between a meridian-marking method and a surgeon's-intuition method. Hayashi Eye Hospital, Fukuoka, Japan. Randomized controlled trials. Eyes scheduled for phacoemulsification were randomized to 1 of 2 groups: a 2.65 mm steepest-meridian CCI using the meridian-marking method or a 2.65 mm steepest-meridian CCI using the surgeon's intuition. Regular and irregular corneal astigmatism, surgically induced astigmatism (SIA) vector, refractive status, higher-order aberrations (HOAs), uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and physical meridian misalignment of the steepest-meridian CCI measured using anterior segment optical coherence tomography were evaluated preoperatively and 1 month and 3 months postoperatively. The mean meridian misalignment of the steepest-meridian CCIs was significantly smaller in the meridian-marking group (4.4 degrees ± 2.8 [SD]) than in the surgeon's-intuition group (8.6 ± 4.4 degrees) (P ≤.0001). Regular and irregular corneal astigmatism and corneal HOAs did not change significantly postoperatively in either group. No significant difference was found in regular or irregular corneal astigmatism, refractive cylinder, manifest spherical equivalent value, SIA, HOAs, UDVA, or CDVA between the meridian-marking group and the surgeon's-intuition group throughout the follow-up. The physical meridian misalignment of steepest-meridian CCI was significantly smaller with the meridian-marking method than with the surgeon's-intuition method; however, the effect of the difference was not large enough to decrease remaining astigmatism and HOAs or to improve the UDVA. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. [The application of vector analysis for evaluation of astigmatism correction in the corneal refractive surgery].

    PubMed

    Zhang, Jiamei; Wang, Yan

    2016-01-01

    Since sixty percent of ametropes obtain astigmatism, which has influence on the visual quality, correcting the astigmatism is always the focus of concerns during visual correction procedures especially for the corneal refractive surgery. The postoperative spherical equivalent or residual cylindrical dioptors was used as quantitative index to evaluate the correction of astigmatism previously; however, such results neglect the effect of astigmatic axis shift on the treatment. Taking astigmatism as a vector parameter could describe the magnitude and direction of astigmatism accurately, thus it was increasingly applied in the evaluation of astigmatism correction. This paper reviews the present vector analysis methods, evaluation indexes and its application for the correction of astigmatism in the corneal refractive surgery.

  15. New pinhole sulcus implant for the correction of irregular corneal astigmatism.

    PubMed

    Trindade, Claudio C; Trindade, Bruno C; Trindade, Fernando C; Werner, Liliana; Osher, Robert; Santhiago, Marcony R

    2017-10-01

    To evaluate the effect on visual acuity of the implantation of a new intraocular pinhole device (Xtrafocus) in cases of irregular corneal astigmatism with significant visual impairment. University of São Paulo, São Paulo, Brazil. Prospective case series. Pseudophakic eyes of patients with irregular corneal astigmatism were treated with the pinhole device. The causes of irregular corneal astigmatism were keratoconus, post radial keratotomy (RK), post-penetrating keratoplasty (PKP), and traumatic corneal laceration. The device was implanted in the ciliary sulcus in a piggyback configuration to minimize the effect of corneal aberrations. Preoperative and postoperative visual parameters were compared. The main outcome variables were manifest refraction, uncorrected and corrected distance and near visual acuities, subjective patient satisfaction, and intraoperative and postoperative adverse events and complications. Twenty-one patients (ages 35 to 85 years) were included. There was statistically significant improvement in uncorrected and corrected (CDVA) distance visual acuities. The median CDVA improved from 20/200 (range 20/800 to 20/60) preoperatively to 20/50 (range 20/200 to 20/20) in the first month postoperatively and remained stable over the following months. Manifest refraction remained unchanged, while a subjective visual performance questionnaire revealed perception of improvement in all the tested working distances. No major complication was observed. One case presented with decentration of the device, which required an additional surgical intervention. The intraocular pinhole device performed well in patients with irregular astigmatism caused by keratoconus, RK, PKP, and traumatic corneal laceration. There was marked improvement in visual function, with high patient satisfaction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent refraction following intraocular lens implantation.

    PubMed

    McNeely, Richard N; Moutari, Salissou; Pazo, Eric; Moore, Jonathan E

    2018-01-01

    To investigate the impact of the orientation of preoperative corneal astigmatism on achieving the postoperative target refraction following monofocal intraocular lens (IOL) implantation. This study enrolled 339 eyes who had uneventful cataract surgery or refractive lens exchange (RLE) with subsequent monofocal IOL implantation. Eyes were initially categorized dependent upon axial length and then on the orientation of preoperative anterior corneal astigmatism. Group 1 had against-the-rule (ATR) anterior corneal astigmatism, group 2 had with-the-rule (WTR) anterior corneal astigmatism, and group 3 had oblique (OB) anterior corneal astigmatism. The preoperative corneal astigmatism was determined by the IOLMaster (Carl Zeiss Meditec AG). Postoperative refraction was completed for all eyes, and the results were calculated and compared for the separate groups. In eyes with axial lengths greater than 22.0 mm and less than 25.0 mm there was a significant difference between the magnitude of preoperative corneal astigmatism between groups 2 and 3 with 0.827 ± 0.376 D in group 2, and 0.677 ± 0.387 D in group 3. The mean postoperative spherical equivalent (SE) prediction error was - 0.132 ± 0.475 D in group 1, 0.026 ± 0.497 D in group 2, and - 0.130 ± 0.477 D in group 3. There was a significant difference between groups 1 and 2. There was no significant difference in the magnitude of preoperative corneal astigmatism and postoperative SE prediction error between the anterior corneal astigmatism orientation groups in eyes with axial lengths of less than or equal to 22.0 mm and greater than or equal to 25.0 mm. The orientation of preoperative anterior corneal astigmatism significantly affected the postoperative biometry prediction error in eyes with astigmatism of 1.75 D or less in eyes with the axial length between 22.0 mm and 25.0 mm. However, the results were not clinically significant.

  17. Characteristics of astigmatism as a function of age in a Hong Kong clinical population.

    PubMed

    Leung, Tsz-Wing; Lam, Andrew Kwok-Cheung; Deng, Li; Kee, Chea-Su

    2012-07-01

    To characterize astigmatism as a function of age in a Hong Kong clinical population. All records from new clinical patients at a university optometry clinic in the year 2007 were used for the study. Only data from subjects with corrected visual acuity ≥6/9 in both eyes and with completed subjective refraction were analyzed. The subjects were divided into seven age groups by decade (i.e., 3 to 10 years, 11 to 20 years, …, >60 years). Refractive errors were decomposed into spherical-equivalent refractive error (M), J0, and J45 astigmatic components for analyses. Internal astigmatism was calculated by subtracting corneal astigmatism from refractive astigmatism (RA). Of the 2759 cases that fulfilled our selection criteria, 58.9% had myopia (M ≥-0.75 D) and 28.4% had RA (Cyl ≥ 1.00 D). The prevalence of RA increased from 17.8% in the 3 to 10 years age group to 38.1% in the 21 to 30 years age group. It then dipped to 25.8% in 41 to 50 years age group but increased again to 41.8% in the >60 years age group. Among the astigmats, almost all 3- to 10-year-old children (92.6%) had with-the-rule (WTR) astigmatism, but a majority of the elderly (>60 years) had against-the-rule (ATR) astigmatism (79.7%). For a subset of subjects who had both subjective refraction and keratometric readings (n = 883), RA was more strongly correlated with corneal (r = 0.35 to 0.74) than with internal astigmatism (r = 0.01 to 0.35). More importantly, the magnitudes of both refractive and corneal J0 were consistent with synchronized decrements (-0.15 and -0.14 D per 10 years, respectively) after the age of 30 years, indicating that the shift toward more ATR astigmatism was related to corneal change. In this Hong Kong Chinese clinical population, the prevalence rates of both myopia and astigmatism increased during the first three decades and shared a similar trend before the age of 50 years. The manifest astigmatism was mainly corneal in nature, bilaterally mirror symmetric in axis, and

  18. Corneal Irregular Astigmatism and Curvature Changes After Small Incision Lenticule Extraction: Three-Year Follow-Up.

    PubMed

    Sideroudi, Haris; Lazaridis, Apostolos; Messerschmidt-Roth, Anke; Labiris, Georgios; Kozobolis, Vassilios; Sekundo, Walter

    2018-04-27

    To evaluate the long-term changes in anterior and posterior corneal irregular astigmatism and curvatures after small incision lenticule extraction (SMILE). Fifty eyes of 28 patients underwent SMILE for myopic astigmatism. All procedures were performed using the VisuMax® femtosecond laser. A Scheimpflug camera was used for preoperative and 3-year postoperative tomography. Anterior and posterior corneal Fourier parameters (spherical component, regular astigmatism, asymmetry, and irregularity) and curvature data were evaluated and compared within 2 subgroups according to the magnitude of the refractive correction (low myopia group: spherical equivalent (SEQ) ≥ -6 D; high myopia group: (SEQ) < -6 D). Associations between all studied parameters were examined. Three years postoperatively, an increase in anterior corneal curvatures and Fourier parameters was detected and the results were strongly correlated with the preoperative SEQ, lenticule thickness, and volume. At the posterior cornea, the flattest radius, corneal astigmatism, spherical component, regular astigmatism, and irregularity decreased only in the high myopia group. A correlation was found between changes in posterior astigmatism and changes in anterior radii (R = 0.349, P = 0.014), SEQ (R = 0.396, P = 0.0049), and lenticule thickness (R = -0.414, P = 0.0031). Moreover, changes in posterior corneal irregularity correlated with the changes in anterior and posterior radii (R = -0.3, P = 0.034, and R = 0.449, P = 0.0012, respectively), changes in preoperative SEQ (R = 0.284, P = 0.0477), and lenticule thickness (R = -0.311, P = 0.0298). Three years after SMILE, there was a reduction of posterior astigmatism in high refractive corrections. This could result in undercorrection in high refractive treatments. Total irregularities increased despite the compensatory effect of the posterior corneal surface.

  19. Visual Outcomes and Aberrometric Changes With Topography-Guided Photorefractive Keratectomy Treatment of Irregular Astigmatism After Penetrating Keratoplasty.

    PubMed

    Bandeira E Silva, Francisco; Hazarbassanov, Rossen Mihaylov; Martines, Eduardo; Güell, José Luis; Hofling-Lima, Ana L

    2018-03-01

    To evaluate the visual acuity and keratometric and aberrometric changes in patients with corneal transplants (PKP), who underwent topography-guided photorefractive keratectomy (TG-PRK) with mitomycin C (MMC). In this case study, 15 patients with spherical equivalents ranging from -11.00 to -0.25 diopters (D) who underwent penetrating corneal transplantation and had irregular astigmatism ranging from -7.5 to -2.0 D underwent TG-PRK with MMC. Corneal topography and wavefront of all patients were measured preoperatively and 12 months postoperatively. Twelve months after TG-PRK with MMC, 46% of eyes achieved a best spectacle-corrected visual acuity (BSCVA) of 20/20 compared with 1 eye preoperatively (P = 0.0221, χ test). The BSCVA did not improve in 1 patient and increased by 1 line or more in all others. Astigmatism decreased significantly (P = 0.003) from 5.10 ± 0.4 D to 3.37 ± 0.06 D, the corneal best-fit sphere increased and keratometry measurements flattened significantly (P = 0.0001 for both comparisons), and the corneal total root mean square aberrations and trefoil decreased significantly (P = 0.0077 and P = 0.0054, respectively) from 9.11 ± 2.56 μm to 7.58 ± 3.15 μm and 2.00 ± 1.2 to 1.38 ± 0.27 μm, respectively, as measured by wavefront aberrometry. Twelve months postoperatively, the BSCVA improved significantly, the lines of vision increased, and astigmatism, corneal best-fit sphere, mean keratometry, corneal thickness, corneal root mean square total, and corneal spherical aberrations decreased. TG-PRK with MMC is a good alternative for correcting post-PKP cases with irregular astigmatism with elevated higher-order aberrations.

  20. Analysis of corneal astigmatism with NIDEK axial length scan in caucasian cataract surgery candidates.

    PubMed

    Duman, R; Duman, R; Cetinkaya, E; Sabaner, M C; Inan, S; Doğan, M; Doğan, I

    2018-04-01

    The aim of the study was to analyze and quantify the pattern of corneal astigmatism in Caucasian cataract surgery patients using a new optical biometer (axial length [AL] Scan, NIDEK Co., Gamagori, Japan). The datasets of cataract surgery patients acquired between March 1, 2014, and April 15, 2016, were collected and analyzed. The corneal power (flat keratometry, steep keratometry, and mean keratometry), negative cylinder power, and axis of astigmatism were recorded. Keratometry values were optically measured by optical low coherence interferometry (AL-Scan, NIDEK Co., Ltd.,) before cataract extraction. The study comprised 1233 eyes of 838 consecutive cataract candidates with a mean age of 66.8 ± 10.7 years (range 40-97 years). The mean keratometry value and corneal astigmatism were 43.69 ± 1.61 D and 0.84 ± 0.70 D, respectively. Corneal astigmatism of 1.00 D or greater was found in 344 eyes (27.9%), and 548 eyes (44.4%) had against-the-rule astigmatism. A trend toward decreasing J0 and J45 with age was found by linear regression models. The per-year increase in age was associated with a J0 and J45 decrease of 0.002 D and 0.001D, respectively. This study provides the distribution of astigmatism axis and power for cataract patients in age subsets from Turkey.

  1. Refractive, corneal and ocular residual astigmatism: distribution in a German population and age-dependency - the Gutenberg health study.

    PubMed

    Schuster, Alexander Karl-Georg; Pfeiffer, Norbert; Schulz, Andreas; Hoehn, René; Ponto, Katharina A; Wild, Philipp S; Blettner, Maria; Beutel, Manfred E; Lackner, Karl J; Münzel, Thomas; Mirshahi, Alireza

    2017-12-01

    Worldwide, the most frequent cause of visual impairment is uncorrected refractive error. This analysis focused on the distribution and associations of refractive, corneal and ocular residual astigmatism. As part of the Gutenberg Health study, a population-based cross-sectional study was conducted in the general population of Germany. A comprehensive ophthalmological examination including refraction, tonometry, and Scheimpflug imaging of the anterior cornea (Pachycam) was performed. In addition to the magnitude and type (with-the-rule, against-the-rule, oblique) of the refractive or corneal astigmatism, we calculated the vector components (J 0 , J 45 ) of both astigmatisms and calculated the ocular residual astigmatism. We performed multiple quantile regression analysis to evaluate the factors associated with refractive, corneal and ocular residual astigmatisms. A total of 13,558 subjects (49% female) with a mean age of 54.0 years (range 35-74 years) were included in this study. The prevalence of refractive astigmatism (>1.0D) was 13.0% in right eyes and 12.0% in left eyes, and 85% of these subjects wore spectacles. The distribution of refractive astigmatism showed a two-peak distribution with high astigmatism for with-the-rule and against-the-rule astigmatism. The associated factors were corneal curvature, age and sex for the different astigmatisms (p < 0.001). We analyzed the prevalence of different astigmatisms within a European population. We confirmed a shift with aging from with-the-rule to against-the-rule astigmatism to refractive and corneal astigmatism. Astigmatism has a large impact on visual perception; more than 85% of people with astigmatism over one diopter wore glasses for distance vision.

  2. [Control of corneal astigmatism following IOL implantation by Nd:YAG laser selective suture cutting].

    PubMed

    Liu, Y Z; Li, S Z

    1991-09-01

    Nd:YAG laser was used to cut the sutures selectively to reduce the postoperative corneal with-the-rule astigmatism in 48 eyes that underwent posterior chamber IOL implantation. A significant decrease in corneal astigmatism with visual improvement was affected, and the manipulation was simple. The actual procedure with its advantages and disadvantages was discussed.

  3. Distribution of the anterior, posterior, and total corneal astigmatism in healthy eyes.

    PubMed

    Feizi, Sepehr; Naderan, Mohammad; Ownagh, Vahid; Sadeghpour, Fatemeh

    2018-04-01

    To evaluate the magnitude and axis orientation of the anterior, posterior, and total corneal astigmatism in normal healthy eyes of an Iranian population. In a prospective cross-sectional study, ophthalmic and anterior segment parameters of 153 healthy eyes of 153 subjects were evaluated by Galilei dual Scheimpflug analyzer. The magnitude and axis orientation [with-the-rule (WTR), against-the-rule (ATR), and oblique] of the anterior, posterior, and total corneal astigmatism measurements (ACA, PCA, and TCA) were compared according to the age, sex, and other ophthalmic parameters. The mean ± SD age of the study population was 30 ± 5.9 years. The mean magnitude was 1.09 ± 0.76 diopters (D) for ACA, 0.30 ± 0.13 D for PCA, and 1.08 ± 0.77 D for TCA. Males had a significantly higher magnitude of PCA than females (p = 0.041). Most eyes had a WTR anterior astigmatism and an ATR posterior astigmatism. The WTR astigmatism had a higher mean magnitude compared to the ATR and oblique astigmatism in all the astigmatism groups, with a significant difference in the ACA and TCA groups (p < 0.05). PCA magnitude exceeded 0.50 D in only 7.8% of the subjects. ACA, PCA, and TCA were significantly correlated with each other and also had a significant correlation with the anterior and posterior maximum corneal elevation measurements (p < 0.001). The results of this study although are limited due to the small number of participants and confined to our demographics, provided information regarding a population that was not described before and may be helpful in obtaining optimum results in astigmatism correction in refractive surgery or designing new intraocular lenses.

  4. [Prevalence and age-related changes of corneal astigmatism in patients before cataract surgery].

    PubMed

    Michelitsch, M; Ardjomand, N; Vidic, B; Wedrich, A; Steinwender, G

    2017-03-01

    The aim of this study was to determine the extent and the distribution of corneal astigmatism in patients awaiting cataract surgery in a mid-European tertiary clinic centre and hence to establish the demand for methods reducing corneal astigmatism. Keratometry measurements of cataract surgery candidates assigned to a university clinic between January 2013 and October 2014 were recorded and analysed retrospectively. A total of 6900 eyes of 3450 patients with a mean age of 72.5 ± 12.2 were analyzed. The corneal astigmatism was more than 0.5 dioptres (D) in 5193 eyes (75.3 %), >1.0 D in 2641 eyes (38.3 %), >1.5 D in 1304 eyes (18.9 %), >2.0 D in 644 eyes (9.3 %), >2.5 D in 363 eyes (5.3 %), >3.0 D in 236 eyes (3.4 %) and >3.5 D in 149 eyes (2.2 %). With increasing age a shift from with-the-rule astigmatism towards against-the-rule astigmatism was observed. Of the patients admitted for routine cataract surgery at our clinic, 2641 eyes (38.3 %) had an astigmatism greater than 1.0 D. Our data could be helpful in establishing a protocol for using toric intraocular lenses and to determine the costs.

  5. Evaluation of corneal topographic changes and surgically induced astigmatism after transconjunctival 27-gauge microincision vitrectomy surgery.

    PubMed

    Tekin, Kemal; Sonmez, Kenan; Inanc, Merve; Ozdemir, Kubra; Goker, Yasin Sakir; Yilmazbas, Pelin

    2018-04-01

    To evaluate the corneal topographic changes and postvitrectomy astigmatism after 27-gauge (g) microincision vitrectomy surgery (MIVS) by using Pentacam HR-Scheimpflug imaging system. This prospective descriptive study included 30 eyes of 30 patients who underwent 27-g MIVS. All eyes underwent a Pentacam HR examination preoperatively and on the first week, first month and third month postoperatively. The power of the corneal astigmatism, mean keratometry (K m ), K 1 and K 2 values and corneal asphericity (Q value) values for the both front and back surfaces of the cornea, index of surface variance (ISV), index of vertical asymmetry (IVA), index of height asymmetry (IHA), index of height decentration (IHD) and higher-order aberrations including coma, trefoil, spherical aberration, higher-order root-mean-square and total RMS were recorded. Additionally, the mean induced astigmatism was estimated by vector analysis. No statistically significant changes were observed in the mean power of corneal astigmatism, mean keratometry, K 1 and K 2 values, corneal asphericity values, ISV, IVA, IHA, IHD and higher-order aberrations on the first week, first month and third month after the operation. The mean surgically induced astigmatism was calculated as 0.23 ± 0.11 D on the first week, 0.19 ± 0.10 D on the first month and 0.19 ± 0.08 D on the third month postoperatively. Minor corneal surface and induced astigmatic changes are expected to result in rapid visual rehabilitation after pars plana vitrectomy with the 27-g MIVS system.

  6. Comparing surgically induced astigmatism calculated by means of simulated keratometry versus total corneal refractive power.

    PubMed

    Garzón, Nuria; Rodríguez-Vallejo, Manuel; Carmona, David; Calvo-Sanz, Jorge A; Poyales, Francisco; Palomino, Carlos; Zato-Gómez de Liaño, Miguel Á; Fernández, Joaquín

    2018-03-01

    To evaluate surgically induced astigmatism as computed by means of either simulated keratometry (K SIM ) or total corneal refractive power (TCRP) after temporal incisions. Prospective observational study including 36 right eyes undergoing cataract surgery. Astigmatism was measured preoperatively during the 3-month follow-up period using Pentacam. Surgically induced astigmatism was computed considering anterior corneal surface astigmatism at 3 mm with K SIM and considering both corneal surfaces with TCRP from 1 to 8 mm (TCRP 3 for 3 mm). The eyes under study were divided into two balanced groups: LOW with K SIM astigmatism <0.90 D and HIGH with K SIM astigmatism ≥0.90 D. Resulting surgically induced astigmatism values were compared across groups and measuring techniques by means of flattening, steepening, and torque analysis. Mean surgically induced astigmatism was higher in the HIGH group (0.31 D @ 102°) than in the LOW group (0.04 D @ 16°). The temporal incision resulted in a steepening in the HIGH group of 0.15 D @ 90°, as estimated with K SIM , versus 0.28 D @ 90° with TCRP 3 , but no significant differences were found for the steepening in the LOW group or for the torque in either group. Differences between K SIM - and TCRP 3 -based surgically induced astigmatism values were negligible in LOW group. Surgically induced astigmatism was considerably higher in the high-astigmatism group and its value was underestimated with the K SIM approach. Eyes having low astigmatism should not be included for computing the surgically induced astigmatism because steepening would be underestimated.

  7. Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes.

    PubMed

    Choi, Young; Eom, Youngsub; Song, Jong Suk; Kim, Hyo Myung

    2018-05-15

    To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 CD, respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. © 2018 The Korean Ophthalmological Society.

  8. Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes

    PubMed Central

    Choi, Young; Song, Jong Suk; Kim, Hyo Myung

    2018-01-01

    Purpose To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Methods Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. Results The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 cylinder diopters [CD], respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Conclusions Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. PMID:29770640

  9. Measurement centration and zone diameter in anterior, posterior and total corneal astigmatism in keratoconus.

    PubMed

    Fredriksson, Anneli; Behndig, Anders

    2017-12-01

    To investigate the central and paracentral astigmatism and the significance of centration and measurement zone diameter compared to a 3-mm pupil-centred measurement zone in keratoconus and in healthy eyes. Twenty-eight right eyes from 28 KC patients with an inferotemporal cone were selected according to specified criteria based on Oculus Pentacam HR ® measurements and were matched with healthy control eyes. The flat (K1) and steep (K2) keratometry readings were registered from the 'Total Corneal Refractive Power' (TCRP) display as well as the anterior and posterior corneal astigmatism displays (ACA and PCA, respectively). Astigmatic power vectors KP0 and KP45 were calculated and analysed for a 6-mm and two 3-mm zones centred on the corneal apex and the pupil, and for 8 paracentral 3-mm zones. The astigmatism was generally higher in KC. Many astigmatic values in KC differed between the 3-mm pupil-centred and the 3- and 6-mm apex-centred zones in KC. In the controls, no corresponding differences between measurement zones were seen, apart from PCA, which differed. The magnitude and direction of KP0 and KP45 varied greatly between the paracentral measurements in KC. Centration and measurement zone diameter have great impacts on the astigmatic values in KC. A small pupil-centred measurement zone should be considered when evaluating the astigmatism in KC. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Influence of the difference between corneal and refractive astigmatism on LASIK outcomes using solid-state technology.

    PubMed

    Piñero, David P; Ribera, David; Pérez-Cambrodí, Rafael J; Ruiz-Fortes, Pedro; Blanes-Mompó, Francisco J; Alzamora-Rodríguez, Antonio; Artola, Alberto

    2014-12-01

    To evaluate the influence of the difference between preoperative corneal and refractive astigmatism [ocular residual astigmatism (ORA)] on outcomes obtained after laser in situ keratomileusis (LASIK) surgery for correction of myopic astigmatism using the solid-state laser technology. One hundred one consecutive eyes with myopia or myopic astigmatism of 55 patients undergoing LASIK surgery using the Pulzar Z1 solid-state laser (CustomVis Laser Pty Ltd, currently CV Laser) were included. Visual and refractive changes at 6 months postoperatively and changes in ORA and anterior corneal astigmatism and posterior corneal astigmatism (PCA) were analyzed. Postoperatively, uncorrected distance visual acuity improved significantly (P < 0.01). Likewise, refractive cylinder magnitude and spherical equivalent were reduced significantly (P < 0.01). In contrast, no significant changes were observed in ORA magnitude (P = 0.81) and anterior corneal astigmatism (P = 0.12). The mean overall efficacy and safety indices were 0.96 and 1.01, respectively. These indices were not correlated with preoperative ORA (r = -0.15, P = 0.15). Furthermore, a significant correlation was found between ORA (r = 0.81, P < 0.01) and PCA postoperatively, but not preoperatively (r = 0.12, P = 0.25). Likewise, a significant correlation of ORA with manifest refraction was only found postoperatively (r = -0.38, P < 0.01). The magnitude of ORA does not seem to be a predictive factor of efficacy and safety of myopic LASIK using a solid-state laser platform. The higher relevance of PCA after surgery in some cases may explain the presence of unexpected astigmatic residual refractive errors.

  11. Surgically induced astigmatism following trabeculectomy.

    PubMed

    Kim, Gyu Ah; Lee, Si Hyung; Lee, Sang Yeop; Kwon, Hee Jung; Bae, Hyoung Won; Seong, Gong Je; Kim, Chan Yun

    2018-03-14

    Surgically induced astigmatism (SIA) has attracted much interest in recent times because changes in corneal astigmatism can lead to decreased uncorrected visual acuity and patient discomfort. This study aimed to evaluate SIA and to identify factors correlated therewith after trabeculectomy. We retrospectively reviewed medical charts of patients who were treated with trabeculectomy at 120° meridian (superotemporal area on right eye and superonasal area on left eye) by the same surgeon. Preoperative keratometric data were compared with data collected from 2 months to 12 months postoperatively. SIA was evaluated using Naeser's polar value analysis. Using Naeser's method, ΔKP(120) was calculated as 0.7 ± 0.7 (0.82@104°), which indicates a with-the-rule change. After surgery, the combined mean polar values changed significantly (Hotelling T 2  = 22.47; p < 0.001). Multivariate analysis of variance indicated that postoperative intraocular pressure and location of surgery were independent factors that were significantly associated with SIA (p = 0.002 and 0.03, respectively). Trabeculectomy at the 120° meridian was not astigmatically neutral. In addition, the SIA after trabeculectomy appears to be greater in eyes with low postoperative intraocular pressure and a superonasal surgical wound rather than a superotemporal wound.

  12. Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series.

    PubMed

    Kolozsvári, Bence L; Losonczy, Gergely; Pásztor, Dorottya; Fodor, Mariann

    2017-01-13

    Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and

  13. Surgical technique for management of isolated lenticular coloboma with high corneal astigmatism.

    PubMed

    Singh, Simar Rajan; Yangzes, Sonam; Gupta, Rohit; Ram, Jagat

    2018-04-01

    We describe a surgical technique for the correction of isolated congenital lenticular coloboma associated with high corneal astigmatism. Transscleral fixation of the capsular bag with a single eyelet Cionni capsular tension ring was followed by in-the-bag implantation of a toric intraocular lens (IOL). This lead to complete correction of the lenticular defect and perfect alignment of the toric lens. In this case, the child attained an unaided distance visual acuity of 20/30 following amblyopia therapy and a well-aligned toric IOL at 12 months of follow-up. This technique can be used in cases with concomitant lenticular coloboma and significant corneal astigmatism.

  14. Surgical technique for management of isolated lenticular coloboma with high corneal astigmatism

    PubMed Central

    Singh, Simar Rajan; Yangzes, Sonam; Gupta, Rohit; Ram, Jagat

    2018-01-01

    We describe a surgical technique for the correction of isolated congenital lenticular coloboma associated with high corneal astigmatism. Transscleral fixation of the capsular bag with a single eyelet Cionni capsular tension ring was followed by in-the-bag implantation of a toric intraocular lens (IOL). This lead to complete correction of the lenticular defect and perfect alignment of the toric lens. In this case, the child attained an unaided distance visual acuity of 20/30 following amblyopia therapy and a well-aligned toric IOL at 12 months of follow-up. This technique can be used in cases with concomitant lenticular coloboma and significant corneal astigmatism. PMID:29582820

  15. Comparison of astigmatism correction using either peripheral corneal relaxing incisions or toric intraocular lenses.

    PubMed

    Muftuoglu, Ilkay Kilic; Aydin Akova, Yonca; Aksoy, Sibel; Unsal, Erkan

    2016-01-01

    To compare the efficacy and short-term stability of toric intraocular lenses (tIOL) and peripheral cornea relaxing incisions (PCRI) during phacoemulsification. Patients with preexisting corneal astigmatism had cataract surgery either with tIOL (AcrySof Toric) (39 eyes of 35 patients) or standard intraocular lens (AcrySof) + PCRIs (38 eyes of 33 patients). Patients were retrospectively evaluated for manifest refraction, corneal topography, and uncorrected and corrected visual acuities preoperatively and at postoperative 1 and 6 months. The Alpins vectorial method was used to analyze the target induced astigmatism (TIA) and surgically induced astigmatism (SIA), magnitude of error (the difference between the magnitude of SIA and TIA) (ME), and correction index. Mean preoperative corneal astigmatism was 2.21 ± 1.32 D in the tIOL group and 2.24 ± 0.96 D in the PCRI group; the difference was not significant. The decrease in astigmatism was significant in both groups at last follow-up (64% tIOL group, 32% PCRI group, p<0.01, Wilcoxon signed rank test). The mean remaining refractive astigmatism was significantly higher in the PCRI group than in the tIOL group at 1-month (1.42 ± 1.22, 0.89 ± 0.68, respectively) and 6-month follow-ups (1.75 ± 1.37 D, 0.92 ± 0.72, respectively) (p<0.01). The mean ME was significantly lower (-0.35 versus -0.88) with a higher correction index (0.96 versus 0.56) in the tIOL group at 6 months postoperatively. Both tIOL implantation and using PCRI were effective methods to reduce preoperative astigmatism at the time of the cataract surgery. However, tIOLs provided better remaining astigmatism with a more stable refraction than PCRI.

  16. Wound stability and surgically induced corneal astigmatism after transconjunctival single-plane sclerocorneal incision cataract surgery.

    PubMed

    Hayashi, Ken; Ogawa, Soichiro; Yoshida, Motoaki; Yoshimura, Koichi

    2017-01-01

    To compare intraocular pressure (IOP) immediately after cataract surgery, and surgically induced corneal astigmatism (SIA) and corneal shape changes between eyes with transconjunctival single-plane sclerocorneal incisions (TSSIs) and eyes with clear corneal incisions (CCIs). Bilateral eyes of 64 patients undergoing phacoemulsification were randomized to undergo 2.4-mm temporal TSSI or CCI. IOP was measured preoperatively, and in the immediate postoperative periods. SIA was determined using vector analysis, and corneal shape changes and irregular astigmatism were evaluated using a videokeratography preoperatively, and in the early postoperative periods. Wound hydration was performed in 23 eyes (35.9 %) of the TSSI group and in 60 (93.8 %) of the CCI group (P < 0.0001). Mean IOP was significantly higher in the TSSI group than in the CCI group at 30, 60, and 120 min postoperatively (P ≤ 0.0179). SIA tended to be smaller in the TSSI group than the CCI group, but the difference was not significant. The higher order irregular astigmatism was smaller in the TSSI group than in the CCI group at 2 days (P = 0.0312). The videokeratography revealed a wound-related flattening postoperatively in both groups; this change disappeared within 4 weeks in the TSSI group, whereas it persisted until 12 weeks in the CCI group. IOP was significantly higher immediately after TSSI than after CCI and required less wound hydration, suggesting better stability with TSSI. Higher order irregular astigmatism and wound-related corneal flattening were smaller after TSSI than after CCI in the early periods, suggesting that fewer corneal shape changes with TSSI.

  17. Comparison of myopia control between toric and spherical periphery design orthokeratology in myopic children with moderate-to-high corneal astigmatism.

    PubMed

    Zhang, Yu; Chen, Yue-Guo

    2018-01-01

    To compare clinical results between toric and spherical periphery design orthokeratology (ortho-k) in myopic children with moderate-to-high corneal astigmatism. This retrospective study enrolled 62 eyes of 62 subjects using toric ortho-k lenses. These subjects were assigned to the toric group. Based on the one-to-one match principle (same age, proximate spherical equivalence and corneal astigmatism), 62 eyes of 62 subjects were enrolled and included in the spherical group. At one-year follow-up visit, visual acuity, corneal astigmatism, treatment zone decentration, axial elongation and adverse reaction were compared between these two groups. At the one-year visit, corneal astigmatism was significantly lower in the toric group (1.22±0.76 D) than in the spherical group (2.05±0.85 D) ( P =0.012). The mean magnitude of the treatment zone decentration was 0.62±0.42 mm in the toric group and 1.07±0.40 mm in the spherical group ( P =0.004). Axial elongation was significantly slower in the toric group (0.04±0.13 mm) than in the spherical group (0.09±0.13 mm) ( P =0.001). The one-year axial elongation was significantly correlated with initial age ( r =-0.487, P <0.001) and periphery design of ortho-k lens ( r =0.315, P <0.001). The incidence of corneal staining was lower in the toric group (8.1%) than in the spherical group (19.4%) ( P <0.001). Toric periphery design ortho-k lenses may provide lower corneal astigmatism, better centration, slower axial elongation and lower incidence of corneal staining in myopic children with moderate-to-high corneal astigmatism.

  18. Minimizing the IOL power error induced by keratometric power.

    PubMed

    Camps, Vicente J; Piñero, David P; de Fez, Dolores; Mateo, Verónica

    2013-07-01

    To evaluate theoretically in normal eyes the influence on IOL power (PIOL) calculation of the use of a keratometric index (nk) and to analyze and validate preliminarily the use of an adjusted keratometric index (nkadj) in the IOL power calculation (PIOLadj). A model of variable keratometric index (nkadj) for corneal power calculation (Pc) was used for IOL power calculation (named PIOLadj). Theoretical differences (ΔPIOL) between the new proposed formula (PIOLadj) and which is obtained through Gaussian optics ((Equation is included in full-text article.)) were determined using Gullstrand and Le Grand eye models. The proposed new formula for IOL power calculation (PIOLadj) was prevalidated clinically in 81 eyes of 81 candidates for corneal refractive surgery and compared with Haigis, HofferQ, Holladay, and SRK/T formulas. A theoretical PIOL underestimation greater than 0.5 diopters was present in most of the cases when nk = 1.3375 was used. If nkadj was used for Pc calculation, a maximal calculated error in ΔPIOL of ±0.5 diopters at corneal vertex in most cases was observed independently from the eye model, r1c, and the desired postoperative refraction. The use of nkadj in IOL power calculation (PIOLadj) could be valid with effective lens position optimization nondependent of the corneal power. The use of a single value of nk for Pc calculation can lead to significant errors in PIOL calculation that may explain some IOL power overestimations with conventional formulas. These inaccuracies can be minimized by using the new PIOLadj based on the algorithm of nkadj.

  19. Office-based Relaxing Incision Procedure for Correction of Astigmatism after Deep Anterior Lamellar Keratoplasty

    PubMed Central

    Javadi, Mohammad Ali; Feizi, Sepehr; Mirbabaee, Firooz; Fekri, Yousef

    2017-01-01

    Purpose: To report the outcomes of a simple and effective office-based procedure for the correction of astigmatism after deep anterior lamellar keratoplasty (DALK). Methods: This study enrolled 24 consecutive keratoconic eyes that developed an intolerable amount of graft astigmatism after DALK. The location and extension of steep semi-meridians were determined using corneal topography. Office-based relaxing incision procedures were performed at the slit-lamp biomicroscope using a 27-gauge needle. Relaxing incisions were made at the donor-recipient interface on one side of the steepest meridian with an arc length of 45° to 60° and an initial depth of approximately 70–80% of the corneal thickness. Topography was performed after 30–40 minutes and the initial incision was enhanced in depth and length. If an acceptable amount of astigmatism was not achieved, another incision was created at the opposite semi-meridian during the same session. Results: Mean follow-up period was 13.1 ± 7.4 months. Mean preoperative best spectacle corrected visual acuity was 0.26 ± 0.14 logMAR, increasing to 0.22 ± 0.09 logMAR after the procedure (P = 0.20). Mean spherical equivalent refractive error increased from − 4.64 ± 3.06 diopters (D) preoperatively to −6.06 ± 3.15 D postoperatively (P = 0.01). Mean keratometric astigmatism was reduced by 2.95 ± 3.43 D and 5.16 ± 2.97 D measured using subtraction and vector analysis methods, respectively (P < 0.001). Microperforation occurred in one eye, which spontaneously improved with no sequelae. Conclusion: Office-based relaxing incision is a safe and effective procedure for the treatment of corneal graft astigmatism after DALK. This approach effectively decreases the need for the more costly alternative in the operating room. PMID:28540006

  20. The efficacy of a single continuous nylon suture for control of post keratoplasty astigmatism.

    PubMed Central

    Van Meter, W

    1996-01-01

    PURPOSE: Post operative adjustment of a single continuous suture is an effective means of reducing post keratoplasty astigmatism. This study evaluates post keratoplasty keratometry following suture adjustment with an adjusted suture in place and after the suture is removed. METHODS: Average keratometric astigmatism was measured over 24 months time in 26 patients with an adjusted continuous suture and 24 patients with a continuous suture that was not adjusted. Average keratometry in 43 patients with an adjusted continuous suture was compared with 37 patients with combined continuous and interrupted sutures. Finally, suture out astigmatism in 19 adjusted patients was compared to six patients with no adjustment. RESULTS: There was an increase in average corneal astigmatism over two years of 2.2 diopters in the adjusted group and 1.7 diopters in the non-adjusted group with sutures in place. One year following surgery, average keratometry flattened from 47.5 to 42.9 diopters in the adjusted continuous group and from 47.0 to 46.0 diopters in the group with combined continuous and interrupted sutures. Following suture removal, average astigmatism in patients who had suture adjustment was 4.4 diopters +/- 2.5 diopters (range 1-10 diopters), and 6.01 diopters (range 4-7) in the non-adjusted group. CONCLUSIONS: Average post keratoplasty astigmatism increases after a continuous suture is adjusted but the increase is comparable to patients with acceptable astigmatism who do not require adjustment. More progressive corneal flattening over 12 months time is seen with a continuous suture than which combined sutures. Average suture out astigmatism was 4.0 diopters following suture adjustment, compared to an average of 8.4 diopters prior to adjustment. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 7A FIGURE 7B PMID:8981721

  1. Corneal Astigmatism and Aberrations After Combined Femtosecond-Assisted Phacoemulsification and Arcuate Keratotomy: Two-Year Results.

    PubMed

    Chan, Tommy C Y; Ng, Alex L K; Cheng, George P M; Wang, Zheng; Woo, Victor C P; Jhanji, Vishal

    2016-10-01

    To investigate the stability of corneal astigmatism and higher-order aberrations after combined femtosecond-assisted phacoemulsification and arcuate keratotomy. Retrospective, interventional case series. Surgery was performed using a VICTUS (Bausch & Lomb Inc, Dornach, Germany) platform. A single, 450-μm deep, arcuate keratotomy was paired at the 8-mm zone with the main phacoemulsification incision in the opposite meridian. The keratotomy incisions were not opened. Corneal astigmatism and higher-order aberration measurements obtained preoperatively and at 2 months and 2 years postoperatively were analyzed. Fifty eyes of 50 patients (mean age 66.2 ± 10.5 years) were included. The mean preoperative corneal astigmatism was 1.35 ± 0.48 diopters (D). This was reduced to 0.67 ± 0.54 D at 2 months and 0.74 ± 0.53 D at 2 years postoperatively (P < .001). There was no statistically significant difference between postoperative corneal astigmatism over 2 years (P = .392). Both magnitude of error and absolute angle of error were comparable between the 2 postoperative time points (P > .283). At postoperative 2 months and 2 years, 72% and 70% of eyes were within 15 degrees of preoperative meridian of astigmatism, respectively. All wavefront measurements increased significantly at 2 months and 2 years (P < .007), except spherical aberration (P > .150). There was no significant difference in higher-order aberrations between 2 months and 2 years postoperatively (P > .486). Our study showed the stability of femtosecond-assisted arcuate keratotomy. Further studies using other platforms and nomograms are needed to corroborate the findings of this study. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Posterior corneal curvature changes following Refractive Small Incision Lenticule Extraction.

    PubMed

    Ganesh, Sri; Patel, Utsav; Brar, Sheetal

    2015-01-01

    To compare the posterior corneal curvature changes, in terms of corneal power and asphercity, following Refractive Small Incision Lenticule Extraction (ReLEx SMILE) procedure for low, moderate, and high myopia. This retrospective, non randomized, comparative, interventional trial; included 52 eyes of 26 patients, divided in three groups: low myopia (myopia ≤3 D [diopters] spherical equivalent [SE]), moderate myopia (myopia >3 D and <6 D SE), and high myopia (myopia ≥6 D SE). All patients were treated for myopia and myopic astigmatism using ReLEx SMILE. The eyes were examined pre-operatively and 3 months post-operatively using SCHWIND SIRIUS, a three-dimensional rotating Scheimpflug camera with a Placido disc topographer to assess corneal changes with regard to keratometric power and asphericity of the cornea. A statistically significant increase in mean keratometric power in the 3, 5, and 7 mm zones of the posterior corneal surface compared with its pre-ReLEx SMILE value was detected after 3 months in the moderate myopia group (pre-operative [pre-op] -6.14±0.23, post-operative [post-op] -6.29±0.22, P<0.001) and high myopia group (pre-op -6.19±0.16, post-op -6.4±0.18, P<0.001), but there was no significant change in keratometric power of the posterior surface in the low myopia group (pre-op -5.87±0.17, post-op -6.06±0.29, P=0.143). Asphericity (Q-value) of the posterior surface changed significantly (P<0.001) after ReLEx SMILE in the moderate myopia group in the 3, 5, and 7 mm zones, and in the high myopia group in the 3 and 7 mm zones; but there was no significant change in the Q-value in the low myopia group in all three zones (pre-op 0.23±0.43, post-op -0.40±0.71, P=0.170), and in the high myopia group in the 5 mm zone (P=0.228). ReLEx SMILE causes significant changes in posterior corneal keratometric power and asphericity in moderate and high myopia, but the effect is subtle and insignificant in low myopia.

  3. Posterior corneal curvature changes following Refractive Small Incision Lenticule Extraction

    PubMed Central

    Ganesh, Sri; Patel, Utsav; Brar, Sheetal

    2015-01-01

    Purpose To compare the posterior corneal curvature changes, in terms of corneal power and asphercity, following Refractive Small Incision Lenticule Extraction (ReLEx SMILE) procedure for low, moderate, and high myopia. Methods This retrospective, non randomized, comparative, interventional trial; included 52 eyes of 26 patients, divided in three groups: low myopia (myopia ≤3 D [diopters] spherical equivalent [SE]), moderate myopia (myopia >3 D and <6 D SE), and high myopia (myopia ≥6 D SE). All patients were treated for myopia and myopic astigmatism using ReLEx SMILE. The eyes were examined pre-operatively and 3 months post-operatively using SCHWIND SIRIUS, a three-dimensional rotating Scheimpflug camera with a Placido disc topographer to assess corneal changes with regard to keratometric power and asphericity of the cornea. Results A statistically significant increase in mean keratometric power in the 3, 5, and 7 mm zones of the posterior corneal surface compared with its pre-ReLEx SMILE value was detected after 3 months in the moderate myopia group (pre-operative [pre-op] −6.14±0.23, post-operative [post-op] −6.29±0.22, P<0.001) and high myopia group (pre-op −6.19±0.16, post-op −6.4±0.18, P<0.001), but there was no significant change in keratometric power of the posterior surface in the low myopia group (pre-op −5.87±0.17, post-op −6.06±0.29, P=0.143). Asphericity (Q-value) of the posterior surface changed significantly (P<0.001) after ReLEx SMILE in the moderate myopia group in the 3, 5, and 7 mm zones, and in the high myopia group in the 3 and 7 mm zones; but there was no significant change in the Q-value in the low myopia group in all three zones (pre-op 0.23±0.43, post-op −0.40±0.71, P=0.170), and in the high myopia group in the 5 mm zone (P=0.228). Conclusion ReLEx SMILE causes significant changes in posterior corneal keratometric power and asphericity in moderate and high myopia, but the effect is subtle and insignificant in low

  4. Changes in corneal shape after suture cutting using the argon laser for postoperative astigmatism following cataract extraction.

    PubMed

    Hayashi, K; Nakao, F; Hayashi, F

    1993-03-01

    We studied the changes in corneal shape after suture cutting with an argon laser to reduce corneal astigmatism following cataract extraction. Sixty-two patients who exhibited high with-the-rule astigmatism (> 3 diopters [D]) following extracapsular lens extraction had argon laser suture cutting. The patients were classified into three groups: Group A comprised 30 patients whose sutures were cut two to three months after planned extracapsular cataract extraction (p-ECCE); Group B consisted of eight patients who had the same treatment five to nine months after p-ECCE; Group C comprised 24 patients who had the treatment one to two months after phacoemulsification (PE). The dioptric reduction of corneal astigmatism (the percent reduction of astigmatism) was 1.83 +/- 0.98 D (37.4 +/- 18.3%) in Group A, 3.20 +/- 2.35 D (55.6 +/- 34.4%) in Group B, and 2.08 +/- 1.20 D (41.4 +/- 20.4%) in Group C. There was no statistical significance in the dioptric reduction and the percent reduction among Groups A, B, and C. This suggests that the wound size and time of cutting are not directly correlated to the effect of argon laser suture cutting. To examine the relationship between the effect and changes in corneal shape from suture cutting, we divided the patients into two subgroups; one was Subgroup (+) in which the percent reduction of astigmatism was above 25%; the other was Subgroup (-) in which the percent reduction was below 25%.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Clinical Outcomes of SMILE With a Triple Centration Technique and Corneal Wavefront-Guided Transepithelial PRK in High Astigmatism.

    PubMed

    Jun, Ikhyun; Kang, David Sung Yong; Reinstein, Dan Z; Arba-Mosquera, Samuel; Archer, Timothy J; Seo, Kyoung Yul; Kim, Tae-Im

    2018-03-01

    To comparatively investigate the clinical outcomes, vector parameters, and corneal aberrations of small incision lenticule extraction (SMILE) with a triple centration technique and corneal wavefront-guided transepithelial photorefractive keratectomy (PRK) for the correction of high astigmatism. This retrospective, comparative case series study included 89 eyes (89 patients) that received treatment for myopia with high astigmatism (≥ 2.50 diopters) using SMILE with a triple centration technique (SMILE group; 45 eyes) and corneal wavefront-guided transepithelial PRK (transepithelial PRK group; 44 eyes). Visual acuity measurement, manifest refraction, slit-lamp examination, autokeratometry, corneal topography, and evaluation of corneal wavefront aberration were performed preoperatively and at 1, 3, and 6 months after surgery. The safety, efficacy, vector parameters, and corneal aberrations at 6 months after surgery were compared between the two groups. At 6 months after surgery, the transepithelial PRK and SMILE groups exhibited comparable mean uncorrected distance visual acuities (-0.06 ± 0.07 and -0.05 ± 0.07 logMAR, respectively), safety, efficacy, and predictability of refractive and visual outcomes. There was a slight but statistically significant difference in the correction index between the transepithelial PRK and SMILE groups (0.96 ± 0.11 and 0.91 ± 0.10, respectively). Whereas the transepithelial PRK group exhibited increased corneal spherical aberration and significantly reduced corneal coma and trefoil, no changes in aberrometric values were noted in the SMILE group. Both SMILE with a triple centration technique and corneal wavefront-guided transepithelial PRK are effective and provide predictable outcomes for the correction of high myopic astigmatism, although slight undercorrection was observed in the SMILE group. The triple centration technique was helpful in astigmatism correction by SMILE. [J Refract Surg. 2018;34(3):156-163.]. Copyright 2018

  6. New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism.

    PubMed

    Canovas, Carmen; Alarcon, Aixa; Rosén, Robert; Kasthurirangan, Sanjeev; Ma, Joseph J K; Koch, Douglas D; Piers, Patricia

    2018-02-01

    To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Abbott Medical Optics, Inc., Groningen, the Netherlands. Retrospective case report. In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon-estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism (P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against-the-rule, with-the-rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups (P < .001). The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Validity of autorefractor based screening method for irregular astigmatism compared to the corneal topography- a cross sectional study.

    PubMed

    Galindo-Ferreiro, Alicia; De Miguel-Gutierrez, Julita; González-Sagrado, Manuel; Galvez-Ruiz, Alberto; Khandekar, Rajiv; Schellini, Silvana; Galindo-Alonso, Julio

    2017-01-01

    To present a method of screening for irregular astigmatism with an autorefractor and its determinants compared to corneal topography. This cross-sectional validity study was conducted in 2013 at an eye hospital in Spain. A tabletop autorefractor (test 1) was used to measure the refractive status of the anterior surface of the cornea at two corneal meridians of each eye. Then corneal topography (test 2) and Bogan's classification was used to group eyes into those with regular or no astigmatism (GRI) and irregular astigmatism (GRII). Test 1 provided a single absolute value for the greatest cylinder difference (Vr). The receiver operating characteristic (ROC) were plotted for the Vr values measured by test 1 for GRI and GRII eyes. On the basis a Vr value of 1.25 D as cut off, sensitivity, specificity were also calculated. The study sample was comprised of 260 eyes (135 patients). The prevalence of irregular astigmatism was 42% [95% confidence interval (CI): 36, 48]. Based on test 2, there were 151 eyes in GRI and 109 eyes in GRII. The median Vr was 0.75 D (25% quartile, 0.5 D) for GRI and 1.75 D (25% quartile, 1.25 D) for GRII. The area under curve was 0.171 for GRI and 0.83 for GRII. The sensitivity of test I was 78.1% and the specificity was 76.1%. A conventional autorefractor can be effective as a first level screening method to detect irregular corneal astigmatism in places where corneal topography facilities are not available.

  8. Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial.

    PubMed

    Visser, Nienke; Beckers, Henny J M; Bauer, Noel J C; Gast, Sacha T J M; Zijlmans, Bart L M; Berenschot, Tos T J M; Webers, Carroll A; Nuijts, Rudy M M A

    2014-12-01

    Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism. A multicenter, hospital-based, randomized clinical trial was conducted. The participants included 86 individuals with bilateral cataract and bilateral corneal astigmatism of at least 1.25 diopters (D) who were randomized to receive either bilateral toric (n = 41) or bilateral control (n = 45) IOL implantation. Bilateral implantation of an aspherical toric IOL or an aspherical control IOL. Spectacle independency for distance vision, uncorrected distance visual acuity, refractive astigmatism, contrast sensitivity, wavefront aberrations, and refractive error-related quality-of-life questionnaire. Preoperatively, mean (SD) corneal astigmatism was 2.02 (0.95) D and 2.00 (0.84) D in the toric and control groups, respectively. Four patients (5%) were lost to follow-up. At 6 months postoperatively, 26 (70%) of the patients in the toric group achieved an uncorrected distance visual acuity of 20/25 or better compared with 14 (31%) in the control group (P < .001; odds ratio, 5.23; 95% CI, 2.03-13.48). Spectacle independency for distance vision was achieved in 31 patients (84%) in the toric group compared with 14 patients (31%) in the control group (P < .001; odds ratio, 11.44; 95% CI, 3.89- 33.63). Mean refractive astigmatism was -0.77 (0.52) D and -1.89 D (1.00) D, respectively. Vector analysis of toric IOLs showed a mean magnitude of error of +0.38 D, indicative of overcorrection. No significant differences were found in contrast sensitivity, higher-order aberrations, or refractive error-related quality of life. In patients with cataract and corneal astigmatism, bilateral toric IOL implantation results in

  9. Development of a nomogram for femtosecond laser astigmatic keratotomy for astigmatism after keratoplasty.

    PubMed

    St Clair, Ryan M; Sharma, Anushree; Huang, David; Yu, Fei; Goldich, Yakov; Rootman, David; Yoo, Sonia; Cabot, Florence; Jun, Jason; Zhang, Lijun; Aldave, Anthony J

    2016-04-01

    To develop a nomogram for femtosecond laser astigmatic keratotomy (AK) to treat post-keratoplasty astigmatism. Three academic medical centers. Retrospective interventional case series. A review of post-keratoplasty femtosecond laser AK was performed. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and keratometry were recorded preoperatively and 1, 3, 6, and 12 months postoperatively. The location, length, depth, and diameter of the AK incisions were recorded, and the surgically induced astigmatic correction was related to these variables using regression analysis. One hundred forty femtosecond laser AK procedures were performed after penetrating keratoplasty (PKP) (n = 129) or deep anterior lamellar keratoplasty (DALK) (n =11), with 89 procedures (80 PKP, 9 DALK) included in the analysis. The mean CDVA improved from 20/59 (0.47 logMAR ± 0.38 [SD]) preoperatively to 20/45 (0.35 ± 0.31 logMAR) postoperatively (P = .013) (n = 46). The mean keratometric astigmatism decreased from 8.26 ± 2.90 diopters (D) preoperatively to 3.62 ± 2.59 D postoperatively (P < .0001) (n = 89). The mean refractive cylinder decreased from 6.77 ± 2.80 D preoperatively to 2.85 ± 2.57 D postoperatively (P < .0001) (n = 69). A nomogram for femtosecond laser AK to treat post-keratoplasty astigmatism was generated using regression analysis. Femtosecond laser AK significantly improved UDVA and CDVA and significantly reduced keratometric astigmatism and refractive cylinder after keratoplasty. The nomogram generated should improve the accuracy of post-keratoplasty femtosecond laser AK. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Management of irregular astigmatism.

    PubMed

    Goggin, M; Alpins, N; Schmid, L M

    2000-08-01

    Using a liberal definition of corneal irregularity, modern videokeratoscopy may define approximately 40% of normal corneas with a toric refractive error as possessing primary irregular astigmatism. The causes of secondary forms of irregular astigmatism include corneal surgery, trauma, dystrophies, and infections. Internal refractive surface and media irregularity or noncorneal astigmatism (ocular residual astigmatism) contribute to irregular astigmatism of the entire refractive path of which crystaline lenticular astigmatism is usually the principal contributing component. Treatment options have increased in recent years, particularly, though not exclusively, through the advent of tailored corneal excimer laser ablations. However, discussion continues concerning the systematic approach necessary to enable treatment to achieve an optimal optical surface for the eye. Discussion also continues as to what constitutes the optimal corneal shape. Some refractive procedures may increase higher order aberrations in the attempt to neutralize refractive astigmatism. The way to further refinement of the commonly performed refractive techniques will ultimately lie in the integrated inclusion of a trio of technologies: topographic analysis of the corneal surface, wavefront analysis of ocular refractive aberrations, and vector planning to enable the appropriate balance in emphasis between these two diagnostic modalities. For the uncommon, irregularly roughened corneas, the ablatable polymer techniques show some promise.

  11. Predictors of femtosecond laser intrastromal astigmatic keratotomy efficacy for astigmatism management in cataract surgery.

    PubMed

    Day, Alexander C; Stevens, Julian D

    2016-02-01

    To evaluate the factors associated with the efficacy of femtosecond laser intrastromal astigmatic keratotomy (AK). Moorfields Eye Hospital, London, United Kingdom. Prospective case series. Eyes having intrastromal AK for corneal cylinder correction were analyzed. Preoperative biometric parameters included axial length, anterior chamber depth, central corneal thickness, and Ocular Response Analyzer corneal hysteresis (CH) and corneal resistance factor (CRF). Preoperative and 1-month postoperative corneal keratometry was measured using the Topcon KR8100PA topographer-autorefractor. Astigmatic analyses were performed using the Alpins method. The study analyzed 319 eyes of 213 patients with a mean target induced astigmatism of 1.24 diopters (D) ± 0.44 (SD), mean surgically induced astigmatism (SIA) of 0.71 ± 0.43 D, and mean difference vector of 0.79 ± 0.41 D. Two multiple regression models were constructed for SIA prediction. Model 1, based on previous manual limbal relaxing incision parameters, confirmed age and astigmatism meridian (with/against the rule and oblique) to be associated with SIA in addition to AK arc length, AK start depth, and preoperative corneal cylinder magnitude. Model 2, additionally considering other parameters, found only lower CH (-0.06 DC per unit CH), a higher CRF (0.04 D per unit CRF), and the astigmatism meridian to be independent predictors of greater SIA (after adjusting for intrastromal AK arc length, start depth, and preoperative corneal cylinder). With-the-rule astigmatism was associated with a 0.13 D higher SIA than against-the-rule astigmatism, holding all other variables constant. Corneal biomechanical parameters and astigmatism meridian were independent predictors of femtosecond laser intrastromal AK efficacy even after adjusting for AK arc length, AK start depth, and preoperative corneal cylinder. Dr. Stevens is a previous consultant to Optimedica, Inc. which is now part of Abbott Medical Optics, Inc. Drs. Stevens and Day have

  12. Femtosecond-Assisted Arcuate Keratotomy for the Correction of Postkeratoplasty Astigmatism: Vector Analysis and Accuracy of Laser Incisions.

    PubMed

    Loriaut, Patrick; Borderie, Vincent M; Laroche, Laurent

    2015-09-01

    To assess the clinical and refractive outcomes of femtosecond-assisted arcuate keratotomy in postkeratoplasty patients, and the accuracy of the incisions, using optical coherence tomography. This is a retrospective study of patients with high postkeratoplasty astigmatism. Patients with a minimum of 4 diopters (D) of postkeratoplasty regular astigmatism were included. The main outcome measures were corrected distance visual acuity, keratometry, corneal topography, and the depth of corneal incisions. Arcuate keratotomy procedures were performed using the IntraLase Femtosecond laser. The depth of keratotomies was set to 75% of the thinnest pachymetry. Twenty eyes of 20 patients were recruited in this study. The mean age at surgery was 51 years, and the mean follow-up period was 17 ± 7.9 months. The corrected distance visual acuity improved significantly from 20/60 preoperatively to 20/41 after surgery (P = 0.004). The mean preoperative and postoperative spherical equivalents were -4.34 ± 2.91 D and -4.44 ± 3.64 D, respectively (P = 0.49). The mean keratometric cylinder decreased from 9.45 ± 2.97 D (range, 4.2-15.2 D) to 4.64 ± 2.79 D (range, 1.4-11.8 D) (P < 0.001). There was no statistical difference between the mean surgical-induced astigmatism and the mean target-induced astigmatism (P = 0.313). The mean difference between the scheduled and actual incision depth was 10.5 ± 22.2 μm (P = 0.057). No complications occurred during the procedures. Femtosecond-assisted keratotomy seems to be a safe and efficient technique for the reduction of large amounts of corneal astigmatism. Although overcorrection and undercorrection may occur, the visual outcome is satisfactory. Optical coherence tomography analysis reports a good predictability of the depth of incisions.

  13. Astigmatism evaluation prior to cataract surgery.

    PubMed

    Gupta, Pankaj C; Caty, Jane T

    2018-01-01

    To evaluate and summarize literature from the past 18 months reporting advancements and issues in astigmatism assessment prior to cataract surgery. New and updated toric calculators and regression formulas offer the opportunity for more accurate lens selection for our patients. Concurrently, improvements in topographic evaluation of corneal keratometry have allowed for a decrease in unplanned residual corneal astigmatism. Measuring posterior corneal astigmatism is especially valuable in eyes with keratoconus when planning to implant toric intraocular lens (IOL) and now allows access to this patient population. Improved accuracy of astigmatism evaluation now occurs with point reflections on the corneal surface along with the latest generation toric lens formulas which integrated posterior corneal astigmatism, predicted lens position, and intended spherical power of the IOL. These improvements can allow for incorporation of toric lenses in keratoconus patients.

  14. Corneal limbal marking in the treatment of myopic astigmatism with the excimer laser.

    PubMed

    Bucher, Celine; Zuberbuhler, Bruno; Goggin, Michael; Esterman, Adrian; Schipper, Isaak

    2010-07-01

    To determine whether preoperative marking of the limbal cornea improves treatment of myopic astigmatism with the excimer laser. Retrospective study on 108 eyes with myopic astigmatism that underwent LASIK or laser epithelial keratomileusis (LASEK) with the Technolas 217 (Bausch & Lomb) excimer laser. Preoperative limbal marking was performed in 47 eyes (marked group). The 12-month results were used for refractive and visual analysis. The achieved cylinder reduction, spherical reduction, and refractive predictability were similar for the marked and unmarked groups in the overall study collective, in the LASIK and LASEK subgroup analysis, and in a higher astigmatism (> 1.25 diopters) subgroup analysis. Limbal marking showed no influence on the refractive results, and vector analysis showed no significant difference in angle of error among groups. Corneal limbal marking failed to improve the refractive outcome in LASIK and LASEK for myopic astigmatism.

  15. Comparison of Methodologies Using Estimated or Measured Values of Total Corneal Astigmatism for Toric Intraocular Lens Power Calculation.

    PubMed

    Ferreira, Tiago B; Ribeiro, Paulo; Ribeiro, Filomena J; O'Neill, João G

    2017-12-01

    To compare the prediction error in the calculation of toric intraocular lenses (IOLs) associated with methods that estimate the power of the posterior corneal surface (ie, Barrett toric calculator and Abulafia-Koch formula) with that of methods that consider real measures obtained using Scheimpflug imaging: a software that uses vectorial calculation (Panacea toric calculator: http://www.panaceaiolandtoriccalculator.com) and a ray tracing software (PhacoOptics, Aarhus Nord, Denmark). In 107 eyes of 107 patients undergoing cataract surgery with toric IOL implantation (Acrysof IQ Toric; Alcon Laboratories, Inc., Fort Worth, TX), predicted residual astigmatism by each calculation method was compared with manifest refractive astigmatism. Prediction error in residual astigmatism was calculated using vector analysis. All calculation methods resulted in overcorrection of with-the-rule astigmatism and undercorrection of against-the-rule astigmatism. Both estimation methods resulted in lower mean and centroid astigmatic prediction errors, and a larger number of eyes within 0.50 diopters (D) of absolute prediction error than methods considering real measures (P < .001). Centroid prediction error (CPE) was 0.07 D at 172° for the Barrett toric calculator and 0.13 D at 174° for the Abulafia-Koch formula (combined with Holladay calculator). For methods using real posterior corneal surface measurements, CPE was 0.25 D at 173° for the Panacea calculator and 0.29 D at 171° for the ray tracing software. The Barrett toric calculator and Abulafia-Koch formula yielded the lowest astigmatic prediction errors. Directly evaluating total corneal power for toric IOL calculation was not superior to estimating it. [J Refract Surg. 2017;33(12):794-800.]. Copyright 2017, SLACK Incorporated.

  16. Corneal coupling of astigmatism applied to incisional and ablative surgery.

    PubMed

    Alpins, Noel; Ong, James K Y; Stamatelatos, George

    2014-11-01

    To redefine measures of corneal coupling for use with incisional and ablation procedures for astigmatism. Private clinics, Melbourne, Victoria, Australia. Retrospective nonrandomized study. The measures known as the coupling ratio (CR) and coupling constant (CC) were redefined to ensure validity in most cases of incisional procedures and laser vision correction procedures. In addition, a new measure--the coupling adjustment (CAdj)--was developed to quantify the amount of spherical adjustment that must be applied to compensate for coupling that occurs as a result of astigmatism treatment. These quantitative measures of coupling were applied to retrospective data to show their applicability. Pure myopic, compound myopic, and compound hyperopic astigmatism excimer laser treatments showed a CR close to zero, a CC close to 0.5, and a CAdj close to zero. Incision LRIs showed a CR close to 1.0 and a CC close to zero. In all cases, the coupling measures were consistent for treatments with a larger astigmatic component (>1.0 diopter) but variable when the astigmatic component of the treatment was smaller. The revised definitions of CR and CC can be used with incisional and ablative surgery. Incorporating the CAdj into the planning of spherocylindrical treatments allows one to factor in the effect of the astigmatic treatment on the spherical component and thus to more accurately target the desired spherical equivalent. Dr. Alpins and Mr. Stamatelatos have a financial interest in the Assort software program. Dr. Ong is an employee of Assort. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Irregular Astigmatism After Corneal Transplantation--Efficacy and Safety of Topography-Guided Treatment.

    PubMed

    Laíns, Inês; Rosa, Andreia M; Guerra, Marta; Tavares, Cristina; Lobo, Conceição; Silva, Maria F L; Quadrado, Maria J; Murta, Joaquim N

    2016-01-01

    To analyze the efficacy and safety of topography-guided photorefractive keratectomy (TG-PRK) to treat irregular astigmatism after corneal transplantation. This was a retrospective observational case series. Eyes with irregular astigmatism after penetrating keratoplasty treated with TG-PRK (Allegretto Wave Eye-Q) with the topography-guided customized ablation treatment protocol were included. All treatments had been planned to correct the topographic irregularities, as well as to reduce the refractive error after neutralizing the induced refractive change. Clinical records, treatment plan, and the examinations performed were reviewed and the following data were collected: corrected and uncorrected distance visual acuities; manifest refraction; topographic parameters, and corneal endothelial cell count. We included 31 eyes [30 patients; mean age 45.0 ± 13.4 (SD) years]. At the last postoperative follow-up (mean 9.2 ± 8.2 months), we observed a significant improvement in corrected (P = 0.001) and uncorrected distance visual acuities (P < 0.001). There was a gain of ≥1 uncorrected distance visual acuity line in 96.8% (n = 30) of the eyes. Similarly, the refractive parameters also improved (cylinder P < 0.001; spherical equivalent P = 0.002). At the last visit, 54.8% (n = 17) of the patients presented a spherical equivalent of ±1 D. The 3-mm topographic irregularity also decreased significantly (P < 0.001). There was no significant variation of the corneal endothelial cell count. This is the largest case series of TG-PRK to treat irregular astigmatism in postcorneal transplantation eyes. Our results confirm that TG-PRK is an efficient treatment, associated with significant improvements of both visual acuity and refractive parameters.

  18. Cross-Sectional and Longitudinal Investigation of the Power Vector in Astigmatism: The Yamagata Study (Funagata).

    PubMed

    Namba, Hiroyuki; Kawasaki, Ryo; Sugano, Akira; Nishi, Katsuhiro; Murakami, Takanori; Nishitsuka, Koichi; Kato, Takeo; Kayama, Takamasa; Yamashita, Hidetoshi

    2018-01-01

    To investigate how age and other factors affect astigmatism in Japanese adults over a period of 5 years. We included 512 Japanese participants who had undergone systemic and ophthalmological examinations both in 2005-2007 and in 2010-2012 in Funagata town, Yamagata, Japan. Astigmatism was evaluated using power vector analyses, where J0 represents the power of orthogonal astigmatism. Positive values of J0 indicate with-the-rule astigmatism, whereas negative values indicate against-the-rule (ATR). In this cross-sectional investigation, J0 represented the power of orthogonal astigmatism, and multivariate regression revealed that both J0 and corneal J0 (cJ0) declined with increasing age (both P < 0.001). In a longitudinal investigation spanning 5 years, the mean amounts of change (Δ) in J0 and ΔcJ0 were -0.045 ± 0.308 and -0.072 ± 0.278, respectively. This confirmed an ATR shift with increasing age in most individuals. The age-divided distribution of the magnitude of differences indicated that older age was associated with a larger astigmatic change over a 5-year period in both the cornea and the entire eye. Using multivariate logistic regression, we observed that older age at baseline was a risk factor for low ΔJ0, indicating a large shift toward ATR astigmatism. We confirmed that a refractive and keratometric shift toward ATR astigmatism occurs with aging. Older age at baseline was also associated with a larger magnitude of astigmatic changes over the subsequent 5 years.

  19. The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 1: the effect of higher-order corneal aberrations on refractive astigmatism.

    PubMed

    Motwani, Manoj

    2017-01-01

    To demonstrate how higher-order corneal aberrations can cancel out, modify, or induce lower-order corneal astigmatism. Six representative eyes are presented that show different scenarios in which higher-order aberrations interacting with corneal astigmatism can affect the manifest refraction. WaveLight ® Contoura ablation maps showing the higher-order aberrations are shown, as are results of correction with full measured correction using the LYRA (Layer Yolked Reduction of Astigmatism) Protocol. Higher-order corneal aberrations such as trefoil, quadrafoil, and coma can create ovalization of the central cornea, which can interact with the ovalization caused by lower-order astigmatism to either induce, cancel out, or modify the manifest refraction. Contoura processing successfully determines the linkage of these interactions resulting in full astigmatism removal. Purely lenticular astigmatism appears to be rare, but a case is also demonstrated. The author theorizes that all aberrations require cerebral compensatory processing and can be removed, supported by the facts that full removal of aberrations and its linkage with lower-order astigmatism with the LYRA Protocol has not resulted in worse or unacceptable vision for any patients. Higher-order aberrations interacting with lower-order astigmatism is the main reason for the differences between manifest refraction and Contoura measured astigmatism, and the linkage between these interactions can be successfully treated using Contoura and the LYRA Protocol. Lenticular astigmatism is relatively rare.

  20. Changes in astigmatism and corneal higher-order aberrations after phacoemulsification with toric intraocular lens implantation for mild keratoconus with cataract.

    PubMed

    Kamiya, Kazutaka; Shimizu, Kimiya; Miyake, Toshiyuki

    2016-07-01

    To assess the changes in astigmatism and higher-order aberrations (HOAs) after toric intraocular lens (IOL) implantation for mild non-progressive keratoconus with cataract. We prospectively examined 19 eyes of 19 consecutive keratoconic patients (mean age ± standard deviation, 63.1 ± 9.1 years) who underwent phacoemulsification with toric IOL implantation. We determined uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive astigmatism, corneal astigmatism, corneal HOAs and astigmatic axis rotation both preoperatively and 3 months postoperatively. Logarithm of the minimal angle of resolution (logMAR) UDVA was significantly improved from 1.14 ± 0.50 preoperatively to 0.46 ± 0.33 postoperatively (Wilcoxon signed-rank test, p < 0.001). LogMAR CDVA was also significantly improved from 0.27 ± 0.45 preoperatively to -0.01 ± 0.09 postoperatively (p < 0.001). In 5 of 6 eyes in which the target refraction was emmetropia, postoperative UDVA was better than 20/32. The achieved spherical equivalent correction was within ±0.5 diopters (D) of the targeted correction in 13 (68 %) eyes and 1.0 in 18 (95 %) eyes. The refractive astigmatism was significantly decreased from -1.92 ± 1.73 D preoperatively to -0.70 ± 0.60 D postoperatively (p = 0.006). The corneal astigmatism changed from 2.89 ± 1.30 D preoperatively to 2.98 ± 1.09 D postoperatively (p = 0.492), which was not statistically significant. The corneal HOAs for a 4-mm pupil was changed from 0.47 ± 0.23 µm preoperatively to 0.52 ± 0.26 µm postoperatively (p = 0.211), which was not statistically significant. According to our experience, toric IOL implantation for mild keratoconic patients having rigid gas-permeable lens intolerance appears to be effective for reducing refractive astigmatism without a significant induction of corneal HOAs.

  1. Correlation of major components of ocular astigmatism in myopic patients.

    PubMed

    Mohammadpour, Mehrdad; Heidari, Zahra; Khabazkhoob, Mehdi; Amouzegar, Afsaneh; Hashemi, Hassan

    2016-02-01

    To investigate the correlation of major components of ocular astigmatism in myopic patients in an academic hospital. This cross-sectional study was conducted on 376 eyes of 188 patients who were referred to Farabi Eye Hospital for refractive surgery. Preoperative examinations including refraction and corneal topography were performed for all candidates to measure refractive and corneal astigmatism. Ocular residual astigmatism was calculated using vector analysis. Pearson's correlation and ANOVA analysis were used to evaluate the strength of the association between different types of astigmatism. Both eyes were defined as cluster and the Generalized Estimating Equations (GEE) analysis were performed. Mean age of 119 women (63.3%) and 69 men (36.7%) was 27.8 ± 5.7 years. Mean refractive error based on spherical equivalent was -3.59 ± 1.95D (range, -0.54 to -10.22D). Mean refractive and corneal astigmatism was 1.97 ± 1.3D and 1.85 ± 1.01D, respectively. Mean amount of ORA was 0.65 ± 0.36D.There was a significant correlation between ORA and refractive astigmatism(r=0.23, p<0.001), corneal and refractive astigmatism (r=0.91, p<0.001) and a weak correlation between ORA and corneal astigmatism (r=0.13, p=0.014). There was a significant correlation between J0 and J45 values of ORA and corneal astigmatism (p<0.001). There is a significant correlation between ORA and refractive astigmatism, refractive and corneal astigmatism and a weak correlation between ORA and corneal astigmatism in refractive surgery candidates. Identifying the type of astigmatism and preoperative measurement of ocular residual astigmatism is highly recommended prior to any refractive surgery, especially in cases with significant astigmatism. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 1: the effect of higher-order corneal aberrations on refractive astigmatism

    PubMed Central

    Motwani, Manoj

    2017-01-01

    Purpose To demonstrate how higher-order corneal aberrations can cancel out, modify, or induce lower-order corneal astigmatism. Patients and methods Six representative eyes are presented that show different scenarios in which higher-order aberrations interacting with corneal astigmatism can affect the manifest refraction. WaveLight® Contoura ablation maps showing the higher-order aberrations are shown, as are results of correction with full measured correction using the LYRA (Layer Yolked Reduction of Astigmatism) Protocol. Results Higher-order corneal aberrations such as trefoil, quadrafoil, and coma can create ovalization of the central cornea, which can interact with the ovalization caused by lower-order astigmatism to either induce, cancel out, or modify the manifest refraction. Contoura processing successfully determines the linkage of these interactions resulting in full astigmatism removal. Purely lenticular astigmatism appears to be rare, but a case is also demonstrated. The author theorizes that all aberrations require cerebral compensatory processing and can be removed, supported by the facts that full removal of aberrations and its linkage with lower-order astigmatism with the LYRA Protocol has not resulted in worse or unacceptable vision for any patients. Conclusion Higher-order aberrations interacting with lower-order astigmatism is the main reason for the differences between manifest refraction and Contoura measured astigmatism, and the linkage between these interactions can be successfully treated using Contoura and the LYRA Protocol. Lenticular astigmatism is relatively rare. PMID:28553069

  3. Beveled Femtosecond Laser Astigmatic Keratotomy for the Treatment of High Astigmatism Post–Penetrating Keratoplasty

    PubMed Central

    Cleary, Catherine; Tang, Maolong; Ahmed, Habeeb; Fox, Martin; Huang, David

    2013-01-01

    Purpose To use beveled femtosecond laser astigmatic keratotomy (FLAK) incisions to treat high astigmatism after penetrating keratoplasty. Methods Paired FLAK incisions at a bevel angle of 135 degrees, 65% to 75% depth, and arc lengths of 60 to 90 degrees were performed using a femtosecond laser. One case of perpendicular FLAK was presented for comparison. Vector analysis was used to calculate the changes in astigmatism. Fourier domain optical coherence tomography was used to examine incision morphology. Results Wound gaping requiring suturing was observed in the case of perpendicular FLAK. Six consecutive cases of beveled FLAK were analyzed. Fourier domain optical coherence tomography showed that beveled FLAK caused a mean forward shift of Bowman layer anterior to the incisions of 126 ± 38 μm, with no wound gaping. The mean magnitude of preoperative keratometric astigmatism was 9.8 ± 2.9 diopters (D), and postoperatively it was 4.5 ± 3.2 D (P < 0.05). Uncorrected visual acuity improved from 1.24 ± 0.13 logarithm of the minimum angle of resolution preoperatively to 0.76 ± 0.38 postoperatively (P < 0.05). Best spectacle–corrected visual acuity improved from 0.43 ± 0.33 logarithm of the minimum angle of resolution preoperatively to 0.27 ± 0.24 postoperatively (P = 0.22). Visual results were reduced in 2 patients by cataract progression. Between 1 and 3 months after beveled FLAK, the keratometric cylinder was stable (<1 D change) in 5 of 6 patients, and regressed in 1 patient. No complications occurred. Conclusions Beveled FLAK incisions at varied depth are effective in the management of postkeratoplasty astigmatism. Early postoperative changes stabilized within 1 month in most patients. Further studies are needed to assess long-term outcomes. PMID:22968362

  4. A novel nomogram for the treatment of astigmatism with femtosecond-laser arcuate incisions at the time of cataract surgery

    PubMed Central

    Baharozian, Connor J; Song, Christian; Hatch, Kathryn M; Talamo, Jonathan H

    2017-01-01

    Purpose The purpose of this study was to determine an arcuate incision (AI) nomogram to treat astigmatism during femtosecond laser-assisted cataract surgery. Methods This is a retrospective, cohort study. Femtosecond laser (FSL)-assisted transepithelial AIs were created at a 9.0 mm optical zone, 80% depth, centered on the limbus. We modified the manual Donnenfeld limbal relaxing incision nomogram to 70% for with-the-rule (WTR), 80% for oblique (OBL), and 100% for against-the-rule (ATR) astigmatism. The correction index (CI) equaled AI-induced astigmatism/target-induced astigmatism. Measures included preoperative keratometric corneal cylinder (Pre Kcyl), postoperative Kcyl (Post Kcyl), and postoperative residual refractive astigmatism (Post RRA). Results Mean Pre Kcyl and 1–2 months Post RRA in 161 eyes of 116 patients were 0.626±0.417 diopters (D) (range 0.5–2 D), and 0.495±0.400 D (range 0–1.5 D), respectively. Mean absolute astigmatic changes (Pre Kcyl–Post Kcyl) without accounting for axis change in the WTR, ATR, and OBL groups were 0.165±0.383 D (P<0.001), 0.374±0.536 D (P<0.001), and 0.253±0.416 D (P=0.02), respectively. Mean absolute astigmatic changes using RRA as the postoperative measurement (Pre Kcyl–Post RRA) without accounting for axis change were 0.440±0.461 D (P<0.001), 0.238±0.571 D (P<0.05), 0.154±0.450 (P=0.111) in WTR, ATR, and OBL groups, respectively. CIs for WTR, ATR, and OBL were 0.53, 1.01, and 0.95, respectively. There were no intraoperative or postoperative complications related to the AIs. Conclusion Transepithelial FSL-AIs using the modified Donnenfeld nomogram show potential for management of mild to moderate corneal astigmatism. An increase in the magnitude or reduction of the optical zone size for the treatment of WTR and ATR astigmatism for this nomogram may further improve refractive accuracy. PMID:29075096

  5. A novel nomogram for the treatment of astigmatism with femtosecond-laser arcuate incisions at the time of cataract surgery.

    PubMed

    Baharozian, Connor J; Song, Christian; Hatch, Kathryn M; Talamo, Jonathan H

    2017-01-01

    The purpose of this study was to determine an arcuate incision (AI) nomogram to treat astigmatism during femtosecond laser-assisted cataract surgery. This is a retrospective, cohort study. Femtosecond laser (FSL)-assisted transepithelial AIs were created at a 9.0 mm optical zone, 80% depth, centered on the limbus. We modified the manual Donnenfeld limbal relaxing incision nomogram to 70% for with-the-rule (WTR), 80% for oblique (OBL), and 100% for against-the-rule (ATR) astigmatism. The correction index (CI) equaled AI-induced astigmatism/target-induced astigmatism. Measures included preoperative keratometric corneal cylinder (Pre Kcyl), postoperative Kcyl (Post Kcyl), and postoperative residual refractive astigmatism (Post RRA). Mean Pre Kcyl and 1-2 months Post RRA in 161 eyes of 116 patients were 0.626±0.417 diopters (D) (range 0.5-2 D), and 0.495±0.400 D (range 0-1.5 D), respectively. Mean absolute astigmatic changes (Pre Kcyl-Post Kcyl) without accounting for axis change in the WTR, ATR, and OBL groups were 0.165±0.383 D ( P <0.001), 0.374±0.536 D ( P <0.001), and 0.253±0.416 D ( P =0.02), respectively. Mean absolute astigmatic changes using RRA as the postoperative measurement (Pre Kcyl-Post RRA) without accounting for axis change were 0.440±0.461 D ( P <0.001), 0.238±0.571 D ( P <0.05), 0.154±0.450 ( P =0.111) in WTR, ATR, and OBL groups, respectively. CIs for WTR, ATR, and OBL were 0.53, 1.01, and 0.95, respectively. There were no intraoperative or postoperative complications related to the AIs. Transepithelial FSL-AIs using the modified Donnenfeld nomogram show potential for management of mild to moderate corneal astigmatism. An increase in the magnitude or reduction of the optical zone size for the treatment of WTR and ATR astigmatism for this nomogram may further improve refractive accuracy.

  6. Posterior Corneal Characteristics of Cataract Patients with High Myopia

    PubMed Central

    Jing, Qinghe; Tang, Yating; Qian, Dongjin; Lu, Yi; Jiang, Yongxiang

    2016-01-01

    Purpose To evaluate the characteristics of the posterior corneal surface in patients with high myopia before cataract surgery. Methods We performed a cross-sectional study at the Eye and ENT Hospital of Fudan University, Shanghai, China. Corneal astigmatism and axial length were measured with a rotating Scheimpflug camera (Pentacam) and partial coherence interferometry (IOLMaster) in a high-myopia study group of 167 eyes (axial length ≥ 26 mm) and a control group of 150 eyes (axial length > 20 mm and < 25 mm). Results Total corneal astigmatism and anterior corneal astigmatism values were higher in the high-myopia group than in the control group. There was no significant difference in posterior corneal astigmatism between the high-myopia study group and the control group. In the study group, the mean posterior corneal astigmatism (range 0 – −0.9 diopters) was –0.29 diopters (D) ± 0.17 standard deviations (SD). The steep corneal meridian was aligned vertically (60°–120°) in 87.43% of eyes for the posterior corneal surface, and did not change with increasing age. There was a significant correlation (r = 0.235, p = 0.002) between posterior corneal astigmatism and anterior corneal astigmatism, especially when the anterior corneal surface showed with-the-rule (WTR) astigmatism (r = 0.452, p = 0.000). There was a weak negative correlation between posterior corneal astigmatism and age (r = –0.15, p = 0.053) in the high-myopia group. Compared with total corneal astigmatism values, the anterior corneal measurements alone overestimated WTR astigmatism by a mean of 0.27 ± 0.18 D in 68.75% of eyes, underestimated against-the-rule (ATR) astigmatism by a mean of 0.41 ± 0.28 D in 88.89% of eyes, and underestimated oblique astigmatism by a mean of 0.24 ± 0.13 D in 63.64% of eyes. Conclusions Posterior corneal astigmatism decreased with age and remained as ATR astigmatism in most cases of high myopia. There was a significant correlation between posterior corneal

  7. Posterior Corneal Characteristics of Cataract Patients with High Myopia.

    PubMed

    Jing, Qinghe; Tang, Yating; Qian, Dongjin; Lu, Yi; Jiang, Yongxiang

    2016-01-01

    To evaluate the characteristics of the posterior corneal surface in patients with high myopia before cataract surgery. We performed a cross-sectional study at the Eye and ENT Hospital of Fudan University, Shanghai, China. Corneal astigmatism and axial length were measured with a rotating Scheimpflug camera (Pentacam) and partial coherence interferometry (IOLMaster) in a high-myopia study group of 167 eyes (axial length ≥ 26 mm) and a control group of 150 eyes (axial length > 20 mm and < 25 mm). Total corneal astigmatism and anterior corneal astigmatism values were higher in the high-myopia group than in the control group. There was no significant difference in posterior corneal astigmatism between the high-myopia study group and the control group. In the study group, the mean posterior corneal astigmatism (range 0 - -0.9 diopters) was -0.29 diopters (D) ± 0.17 standard deviations (SD). The steep corneal meridian was aligned vertically (60°-120°) in 87.43% of eyes for the posterior corneal surface, and did not change with increasing age. There was a significant correlation (r = 0.235, p = 0.002) between posterior corneal astigmatism and anterior corneal astigmatism, especially when the anterior corneal surface showed with-the-rule (WTR) astigmatism (r = 0.452, p = 0.000). There was a weak negative correlation between posterior corneal astigmatism and age (r = -0.15, p = 0.053) in the high-myopia group. Compared with total corneal astigmatism values, the anterior corneal measurements alone overestimated WTR astigmatism by a mean of 0.27 ± 0.18 D in 68.75% of eyes, underestimated against-the-rule (ATR) astigmatism by a mean of 0.41 ± 0.28 D in 88.89% of eyes, and underestimated oblique astigmatism by a mean of 0.24 ± 0.13 D in 63.64% of eyes. Posterior corneal astigmatism decreased with age and remained as ATR astigmatism in most cases of high myopia. There was a significant correlation between posterior corneal astigmatism and anterior corneal astigmatism

  8. A new approach based on Machine Learning for predicting corneal curvature (K1) and astigmatism in patients with keratoconus after intracorneal ring implantation.

    PubMed

    Valdés-Mas, M A; Martín-Guerrero, J D; Rupérez, M J; Pastor, F; Dualde, C; Monserrat, C; Peris-Martínez, C

    2014-08-01

    Keratoconus (KC) is the most common type of corneal ectasia. A corneal transplantation was the treatment of choice until the last decade. However, intra-corneal ring implantation has become more and more common, and it is commonly used to treat KC thus avoiding a corneal transplantation. This work proposes a new approach based on Machine Learning to predict the vision gain of KC patients after ring implantation. That vision gain is assessed by means of the corneal curvature and the astigmatism. Different models were proposed; the best results were achieved by an artificial neural network based on the Multilayer Perceptron. The error provided by the best model was 0.97D of corneal curvature and 0.93D of astigmatism. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Interrogation of the platelet-derived growth factor receptor alpha locus and corneal astigmatism in Australians of Northern European ancestry: results of a genome-wide association study.

    PubMed

    Yazar, Seyhan; Mishra, Aniket; Ang, Wei; Kearns, Lisa S; Mountain, Jenny A; Pennell, Craig; Montgomery, Grant W; Young, Terri L; Hammond, Christopher J; Macgregor, Stuart; Mackey, David A; Hewitt, Alex W

    2013-01-01

    Corneal astigmatism is a common eye disorder characterized by irregularities in corneal curvature. Recently, the rs7677751 single nucleotide polymorphism (SNP) at the platelet-derived growth factor receptor alpha (PDGFRA) locus was found to be associated with corneal astigmatism in people of Asian ancestry. In the present study, we sought to replicate this finding and identify other genetic markers of corneal astigmatism in an Australian population of Northern European ancestry. Data from two cohorts were included in this study. The first cohort consisted of 1,013 individuals who were part of the Western Australian Pregnancy Cohort (Raine) Study: 20-year follow-up Eye Study. The second cohort comprised 1,788 individuals of 857 twin families who were recruited through the Twins Eye Study in Tasmania and the Brisbane Adolescent Twin Study. Corneal astigmatism was calculated as the absolute difference between the keratometry readings in two meridians, and genotype data were extracted from genome-wide arrays. Initially, each cohort was analyzed separately, before being combined for meta- and subsequent genome-wide pathway analysis. Following meta-analysis, SNP rs7677751 at the PDGFRA locus had a combined p=0.32. No variant was found to be statistically significantly associated with corneal astigmatism at the genome-wide level (p<5.0×10(-8)). The SNP with strongest association was rs1164064 (p=1.86×10(-6)) on chromosome 3q13. Gene-based pathway analysis identified a significant association between the Gene Ontology "segmentation" (GO:0035282) pathway, corrected p=0.009. Our data suggest that the PDGFRA locus does not transfer a major risk of corneal astigmatism in people of Northern European ancestry. Better-powered studies are required to validate the novel putative findings of our study.

  10. Comparison of toric intraocular lenses and peripheral corneal relaxing incisions to treat astigmatism during cataract surgery.

    PubMed

    Mingo-Botín, David; Muñoz-Negrete, Francisco José; Won Kim, Hae Ryung; Morcillo-Laiz, Rafael; Rebolleda, Gema; Oblanca, Noelia

    2010-10-01

    To evaluate and compare toric intraocular lens (IOL) implantation and spherical IOL implantation with peripheral corneal relaxing incisions to manage astigmatism during phacoemulsification. Ophthalmology Service, Hospital Ramón y Cajal, Madrid, Spain. Prospective randomized comparative case series. Eyes with cataract and corneal astigmatism (1.00 to 3.00 diopters [D]) had toric IOL implantation or peripheral corneal relaxing incisions. Outcome measures were visual outcomes, slitlamp assessment, digital toric IOL axis determination, spectacle need, and patient satisfaction. Three months postoperatively, the mean uncorrected distance visual acuity (UDVA) was 0.13 ± 0.10 (SD) in the toric IOL group and 0.19 ± 0.12 in the relaxing incisions group; the UDVA was better than 0.20 in 75% of eyes and 60% of eyes, respectively. Refractive cylinder decreased significantly in both groups, with a mean residual refractive astigmatism of 0.61 ± 0.41 D in the toric IOL group and 1.32 ± 0.60 D in the relaxing incisions group (P<.01). The mean toric IOL rotation was 3.65 ± 2.96 degrees, with no significant differences between slitlamp and digital photograph measurements. There was a trend toward better mesopic contrast sensitivity with glare in the toric IOL group. There were no differences in VF-14 or patient satisfaction results; 15% of patients in the toric IOL group and 45% in the relaxing-incision group required distance spectacles postoperatively. Although refractive astigmatism decreased in both groups, toric IOL implantation was more effective and predictable, resulting in greater spectacle independence. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Contact lens rehabilitation following repaired corneal perforations

    PubMed Central

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  12. Comparison of Whole Eye vs. First-Surface Astigmatism in Down Syndrome

    PubMed Central

    Knowlton, Rachel; Marsack, Jason D.; Leach, Norman E.; Herring, Ralph J.; Anderson, Heather A.

    2016-01-01

    Purpose Individuals with Down syndrome (DS) have structural differences in the cornea and lens, as compared to the general population. This study investigates objectively measured refractive and corneal astigmatism, as well as calculated internal astigmatism in subjects with and without DS. Methods Refractive (Grand Seiko autorefraction) and anterior corneal astigmatism (difference between steep and flat keratometry obtained with Zeiss Atlas corneal topography) were measured in 128 subjects with DS (mean age = 24.8±8.7 yrs) and 137 controls without DS (mean age = 24.9±9.9 yrs), with 1 eye randomly selected for analysis per subject. Refractive astigmatism and corneal astigmatism were converted to vector notation (J0, J45) to calculate internal astigmatism (Refractive – Corneal) and then converted back to minus cylinder form. Results Mean refractive astigmatism was significantly greater in subjects with DS than controls (−1.94±1.30DC vs −0.66±0.60DC, t=−10.16, p<0.001), as was mean corneal astigmatism (1.70±1.04DC vs 1.02±0.63DC, t=6.38, p<0.001) and mean internal astigmatism (−1.07±0.68DC vs −0.77±0.41DC, t=−4.21, p<0.001). A positive linear correlation between corneal and refractive astigmatism was observed for both study populations for both the J0 and J45 vectors (p<0.001 for all comparisons, R2 range = 0.31 to 0.74). The distributions of astigmatism orientation differed significantly between the two study populations when compared across all three types of astigmatism (Chi-Square, p<0.001). Conclusions This study demonstrates that corneal astigmatism is predictive of overall refractive astigmatism in individuals with DS, as it is in the general population. The greater magnitudes of astigmatism and wider variation of astigmatism orientation in individuals with DS for refractive, corneal, and calculated internal astigmatism is likely attributable to previously reported differences in the structure of the cornea and internal optical components

  13. Polar Value Analysis of Low to Moderate Astigmatism with Wavefront-Guided Sub-Bowman Keratomileusis

    PubMed Central

    Zhang, Yu

    2017-01-01

    Purpose To evaluate the astigmatic outcomes of wavefront-guided sub-Bowman keratomileusis (WFG-SBK) for low to moderate myopic astigmatism. Methods This study enrolled 100 right eyes from 100 patients who underwent WFG-SBK for the correction of myopia and astigmatism. The polar value method was performed with anterior and posterior corneal astigmatism measured with Scheimpflug camera combined with Placido corneal topography (Sirius, CSO) and refractive astigmatism preoperatively and 1 month, 3 months, and 6 months postoperatively. Results Similar results for surgically induced astigmatism (SIA) and error of the procedure in both anterior corneal astigmatism (ACA) and total ocular astigmatism (TOA). There was a minor undercorrection of the cylinder in both ACA and TOA. Posterior corneal astigmatism (PCA) showed no significant change. Conclusions Wavefront-guided SBK could provide good astigmatic outcomes for the correction of low to moderate myopic astigmatism. The surgical effects were largely attributed to the astigmatic correction of the anterior corneal surface. Posterior corneal astigmatism remained unchanged even after WFG-SBK for myopic astigmatism. Polar value analysis can be used to guide adjustments to the treatment cylinder alongside a nomogram designed to optimize postoperative astigmatic outcomes in myopic WFG-SBK. PMID:28831306

  14. [Astigmatic keratotomy with the femtosecond laser: correction of high astigmatisms after keratoplasty].

    PubMed

    Kook, D; Bühren, J; Klaproth, O K; Bauch, A S; Derhartunian, V; Kohnen, T

    2011-02-01

    The purpose of this study was to evaluate a novel technique for the correction of postoperative astigmatism after penetrating keratoplasty with the use of the femtosecond laser creating astigmatic keratotomies (femto-AK) in the scope of a retrospective case series. Clinical data of ten eyes of nine patients with high residual astigmatism after penetrating keratoplasty undergoing paired femto-AK using a 60-kHz femtosecond laser (IntraLase™, AMO) were analyzed. A new software algorithm was used to create paired arcuate cuts deep into the donor corneal button with different cut angles. Target values were refraction, uncorrected visual acuity, best corrected visual acuity, topographic data (Orbscan®, Bausch & Lomb, Rochester, NY, USA), and corneal wavefront analysis using Visual Optics Lab (VOL)-Pro 7.14 Software (Sarver and Associates). Vector analysis was performed using the Holladay, Cravy and Koch formula. Statistical analysis was performed to detect significances between visits using Student's t test. All procedures were performed without any major complications. The mean follow-up was 13 months. The mean patient age was 48.7 years. The preoperative mean uncorrected visual acuity (logMAR) was 1.27, best corrected visual acuity 0.55, mean subjective cylinder -7.4 D, and mean topometric astigmatism 9.3 D. The postoperative mean uncorrected visual acuity (logMAR) was 1.12, best corrected visual acuity 0.47, mean subjective cylinder -4.1 D, and mean topometric astigmatism 6.5 D. Differences between corneal higher order aberrations showed a high standard deviation and were therefore not statistically significant. Astigmatic keratotomy using the femtosecond laser seems to be a safe and effective tool for the correction of higher corneal astigmatisms. Due to the biomechanical properties of the cornea and missing empirical data for the novel femto-AK technology, higher numbers of patients are necessary to develop optimal treatment nomograms.

  15. Suturing technique for scleral fixation of toric intraocular lens in the traumatic aphakic eye with corneal astigmatism.

    PubMed

    Pan, Qintuo; Yang, Zhengwei; Chen, Xiaomeng; Wei, Wenlong; Ke, Zhisheng; Chen, Ding; Huang, Fang; Cai, Junyong; Zhao, Zhenquan

    2018-04-01

    To describe the clinical outcomes of traumatic aphakic eyes with corneal astigmatism after using a novel technique for toric intraocular lens suture fixation. In total, 12 eyes of 12 patients who underwent a new scleral suture fixation technique of one-piece toric intraocular lens (SN6AT series, Alcon Inc., TX, USA) were included in our retrospective study. Preoperative patient status, postoperative visual acuity and refractive outcomes, postoperative intraocular lens rotation, tilt, decentration, and complications were analyzed. The mean follow-up was 11.6 ± 1.0 months. The mean preoperative best-corrected visual acuity was 0.55 ± 0.32 in the logarithm of minimum angle of resolution equivalent; the postoperative best-corrected visual acuity was 0.45 ± 0.34. The mean preoperative total corneal astigmatism was 2.51 ± 1.67 D. The mean postoperative residual astigmatism was 0.77 ± 0.54 D. The mean intraocular lens rotation was 3.33° ± 1.37° (range, 1°-6°). The mean intraocular lens tilt in horizontal direction was 3.64° ± 1.02° (range, 2.6°-6.3°) and in vertical direction it was 3.19° ± 1.07 ° (range, 1.6°-5.2°). The mean intraocular lens decentration in horizontal direction was 0.14 ± 0.03 mm (range, 0.089-0.192 mm) and in vertical direction it was 0.15 ± 0.02 mm (range, 0.113-0.181 mm). One patient had mild vitreous hemorrhage and two other patients had high postoperative residual sphere and astigmatism, respectively. But no other serious complications were observed. Scleral suture fixation of foldable toric intraocular lens to correct corneal astigmatism can be a safe and effective alternative technique to manage traumatic aphakic eyes that lack adequate capsular support.

  16. Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery

    PubMed Central

    Cho, Yang Kyeung

    2009-01-01

    Purpose To evaluate the factors that affect postoperative astigmatism and post-suture removal astigmatism, and to evaluate the risk factors associated with astigmatism axis shift. Methods We performed a retrospective chart review of 130 eyes that had undergone uneventful phacoemulsification cataract surgery. Preoperative astigmatism was divided into four groups (Groups I, II, III, and IV) according to the differences between the axis of preoperative astigmatism (flattest axis) and the incision axis (105 degrees). We analyzed the magnitude and axis of the induced astigmatism after the operation and after suture removal in each group. We also analyzed the factors which affected the postoperative astigmatism and post-suture removal astigmatism in each sub-group of Groups I, II, III, and IV, excluding postoperative or post-suture removal axis shift (specifically, Group IWAS, IIWAS, IIIWAS, and IVWAS). We identified the variables associated with the prevalence of postoperative astigmatism axis shift and those associated with the prevalence of post-suture removal axis shift. Results An increase in the magnitude of postoperative astigmatism was associated with an increase in the preoperative magnitude of astigmatism in Groups IWAS, IIWAS, and IIIWAS (p<0.05), and with an increase in the corneal tunnel length in Group IWAS. A decrease in the magnitude of postoperative astigmatism was associated with an increase in the corneal tunnel length in Groups IIIWAS and IVWAS (p<0.05). An increase in the magnitude of post-suture removal astigmatism was associated with an increase in the magnitude of postoperative astigmatism in Groups IWAS and IVWAS (p<0.05), and with late suture removal in Group IVWAS (p<0.05). A decrease in the magnitude of post-suture removal astigmatism was associated with late suture removal in Groups IWAS and IIWAS. A logistic regression analysis showed that the prevalence of post-suture removal astigmatism axis shift was associated with increased corneal

  17. [Internal astigmatism with other ocular lesions].

    PubMed

    Limaiem, R; Baba, A; Bouraoui, R; Mghaieth, F; El Matri, L

    2012-04-01

    Astigmatism is a refractive defect whose origin is not always purely corneal, and is sometimes the result of corneal, crystalline lens or mixte contributions. The aim of our study is to report, through two cases, ocular lesions associated with a lenticular astigmatism and their evolution after treatment. In the first observation, it is a 25-year-old patient with a unilateral extra corneal astigmatism within the framework of the "tilted disc syndrome" associated with bilateral myopia. This patient has received treatment by Lasik. The postoperative course was good with a decline of 5 ans. The second observation is that of a patient aged 35 years without having a general history with a posterior lenticonus associated with keratoconus responsible for a major mixed astigmatism. She received combined surgery: penetrating keratoplasty with lens extraction and implantation of an artificial lens. The evolution was good with good visual recovery. The balance of internal astigmatism must include the systematic achievement of a subjective and objective refraction under cycloplegia and corneal topography. The search for etiology is critical to screen for eye or general disease and guide the therapeutic strategy. Knowledge of the refractive power of the cornea and crystalline lens of astigmatism separately would be important for surgery refractive and crystalline lens surgery. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  18. Ocular residual and corneal astigmatism in a clinical population of high school students.

    PubMed

    Chen, Zhao; Liu, Luoru; Pan, Chenglin; Li, Xiaoning; Pan, Lun; Lan, Weizhong; Yang, Zhikuan

    2018-01-01

    Total refractive astigmatism is usually the first consideration that guides the selection of contact lens type (e.g., spherical or toric), while the ocular source of the astigmatism is a second, but more important consideration, for the final clinical decision. This study was conducted to provide detailed data on this topic by evaluating astigmatic components in Chinese adolescents. Participants were recruited from healthy high school students undergoing an annual ocular examination at a local hospital. Total astigmatism (TA), corneal astigmatism (CA), and ocular residual astigmatism (ORA) were determined by a Hartmann-Shack wavefront analyzer system (KR-1W, Topcon) with the natural pupil. The axis relationship between CA and ORA was placed into three categories: on-axis, defined as an axis with a difference of 0 ± 10°; opposite-axis, a difference of 90 ± 10°; and the rest defined as oblique-axis. The study consisted of 1,466 students (57.84% girls, age: 16.49 ± 1.05 years). ORA was present in 83.97%, 66.64%, and 45.23% of participants, according to the various criteria for astigmatism (≥ 0.50 D, ≥ 0.75 D, and ≥ 1.00 D, respectively). While with-the-rule was the most common axis orientation for both TA (76.28%) and CA (89.94%), against-the-rule predominated in ORA (93.82%; χ2 = 1688.544, p < 0.001). Opposite-axis was the major type of axis difference (90.96%) of clinical significance (i.e., ≥ 1.00 D) between CA and ORA, which also prevailed in all levels of TA (range: 56.25-82.26%). ORA is common in high school students and usually demonstrates a compensation relationship with CA, which should be taken into consideration when determining the design of contact lenses to correct refractive error.

  19. Ocular residual and corneal astigmatism in a clinical population of high school students

    PubMed Central

    Liu, Luoru; Pan, Chenglin; Li, Xiaoning; Pan, Lun; Yang, Zhikuan

    2018-01-01

    Purpose Total refractive astigmatism is usually the first consideration that guides the selection of contact lens type (e.g., spherical or toric), while the ocular source of the astigmatism is a second, but more important consideration, for the final clinical decision. This study was conducted to provide detailed data on this topic by evaluating astigmatic components in Chinese adolescents. Methods Participants were recruited from healthy high school students undergoing an annual ocular examination at a local hospital. Total astigmatism (TA), corneal astigmatism (CA), and ocular residual astigmatism (ORA) were determined by a Hartmann-Shack wavefront analyzer system (KR-1W, Topcon) with the natural pupil. The axis relationship between CA and ORA was placed into three categories: on-axis, defined as an axis with a difference of 0 ± 10°; opposite-axis, a difference of 90 ± 10°; and the rest defined as oblique-axis. Results The study consisted of 1,466 students (57.84% girls, age: 16.49 ± 1.05 years). ORA was present in 83.97%, 66.64%, and 45.23% of participants, according to the various criteria for astigmatism (≥ 0.50 D, ≥ 0.75 D, and ≥ 1.00 D, respectively). While with-the-rule was the most common axis orientation for both TA (76.28%) and CA (89.94%), against-the-rule predominated in ORA (93.82%; χ2 = 1688.544, p < 0.001). Opposite-axis was the major type of axis difference (90.96%) of clinical significance (i.e., ≥ 1.00 D) between CA and ORA, which also prevailed in all levels of TA (range: 56.25–82.26%). Conclusions ORA is common in high school students and usually demonstrates a compensation relationship with CA, which should be taken into consideration when determining the design of contact lenses to correct refractive error. PMID:29630629

  20. The Unevenness and Non-orthogonal State of Distribution of Corneal Thickness and the Influence on Correction of Myopic Astigmatism by LASEK.

    PubMed

    Wang, Shulin; Wang, Xin; Liu, Mingna; Wang, Haiying; Li, Jing; Shi, Weiyun

    2015-09-01

    To observe and calculate the unevenness and the non-orthogonal state of distribution of corneal thickness and the relationship between them using Pentacam and to investigate the influence of unevenness and the non-orthogonal state on correction of myopic astigmatism by laser subepithelial keratomileusis (LASEK). 230 eyes with myopic astigmatism treated with LASEK were divided into two groups: 114 eyes as the low astigmatism group (-0.25 to -0.75 DC) and 116 eyes as the midrange-high astigmatism group (-1.00 to -4.50 DC). With the help of the diagram of keratoconus evaluation program of the Pentacam, the D 3.0 and D 6.5 were calculated for the index of distribution of unevenness of the corneal thickness, and the absolute value of the angle between the maximum and minimum progression-index orientation (M 90) for the index of non-orthogonal states. The correction of myopic astigmatism by LASEK was based on standard vector analysis and power vector analysis. The follow-up period was for 3 months. The preoperative M 90 was 22.14° ± 20.87°, D 6.5 was 58.66 ± 21.32 μm, and D 3.0 was 16.11 ± 4.28 μm for the 230 eyes that were tested. The D 6.5 of low astigmatism group (55.62 ± 20.81) μm was significantly lower than that of midrange-high astigmatism group (61.65 ± 21.48) μm (P < 0.05). Of the 230 eyes, the M 90 was positively correlated with D 6.5 (r = 0.37, P < 0.001), and D 6.5 was positively correlated with D 3.0 (r = 0.56, P < 0.001). 3 months postoperatively, the absolute error vector (|EV|) of low astigmatism group (0.46 ± 0.34) was significantly lower than that of midrange-high astigmatism group (0.53 ± 0.29) (P < 0.01). The error of magnitude of low astigmatism group (-0.10 ± 0.31) was significantly lower than that of midrange-high astigmatism group (0.08 ± 0.41) (P < 0.001). The absolute error of angle (|EA|) of low astigmatism group (26.10 ± 27.24) was significantly higher than that of midrange

  1. Correcting lenticular astigmatism by reinstating the correct neuromuscular message.

    PubMed

    Yee, John William

    2013-07-01

    The spasm of the oblique muscles can contribute to lenticular astigmatism. The visual cortex interprets the tension of the oblique muscles as an eye that is in near focus mode. It overrides the response to the information generated by depth perception to bring a distant image into focus. Any excessive effort to bring it into focus will not be successful and continuing to make that effort can cause a misalignment in the tension of the rectus muscles. This in turn can directly induce corneal astigmatism and indirectly induce lenticular astigmatism. The astigmatic eye can still bring a near image into focus, but a distant image remains aberrant. The design of a special contact lens to treat lenticular astigmatism is similar to the design of a contact lens to treat corneal astigmatism by means of orthoculogy (or ortho C) as outlined in the paper Correcting Corneal Astigmatism by Reinstating the Correct Neuromuscular Message. The ortho C lens is worn for about two minutes to attend to the blur and distorted aspects of "simple myopic astigmatism". Both of these refractive errors are corrected simultaneously. Once the oblique muscles become "loose" due to a "contact lens draw", it triggers the visual cortex to reinstate the proper neuromotor message to stimulate the ciliary muscle (the muscle that controls the shape of the crystalline lens) to relax along a certain meridian-which in turn "flattens" the crystalline lens along that meridian to bring a blur and distorted image in the distance into focus. The correction only takes a few minutes because the ciliary muscle of an astigmatic eye was not compromised. The correction is not strictly due to an ortho C lens. Its design is the same for corneal astigmatism or lenticular astigmatism. The purpose of the design is to "loosen" the oblique muscles in a certain manner depending on the degree of astigmatism instead of a specific type of astigmatism. The visual cortex can discriminate whether to correct for corneal astigmatism

  2. Rigid Gas Permeable Contact Lens as a Vision-Sparing Tool in Children After Traumatic Corneal Laceration.

    PubMed

    Elseht, Rabab Mohamed; Nagy, Khaled Ahmed

    2018-05-01

    To evaluate the clinical value of rigid gas permeable contact lenses in children after traumatic corneal scarring. This comparative study included 15 children (age range: 5.7 to 14 years; mean ± standard deviation = 9.4 ± 2.9 years) with corneal scars and best corrected visual acuity (BCVA) of worse than 20/20, history of penetrating ocular trauma, and/or cataract extraction. All children were advised to wear spherical rigid gas permeable contact lenses for 6 months with a special regimen. Visual acuity was compared before and after fitting. The total and anterior surface aberrations of all children were measured using a corneal topographer before and after treatment. There was a significant improvement in the BCVA after wearing rigid gas permeable contact lenses compared to spectacle visual acuity (P = .001). There was also significant improvement of the keratometric astigmatism (P = .001) and corneal aberrations such as higher order aberrations (P = .008), lower order aberrations, root mean square, and point spread function (P = .001). The optical performance of rigid gas permeable contact lenses has been demonstrated to be effective in the visual rehabilitation of children with traumatic corneal lacerations. Corneal topography was an objective tool for detecting optical disorders. [J Pediatr Ophthalmol Strabismus. 2018;55(3):178-181.]. Copyright 2018, SLACK Incorporated.

  3. [Analyzing and tracking preoperative and intraoperative astigmatism].

    PubMed

    Perez, M

    2012-03-01

    Precise evaluation of preoperative astigmatism is the first step optimizing outcomes. This begins with office-based evaluation of astigmatism; corneal astigmatism is evaluated by keratometry, traditionally by Javal keratometry, but now including topography, whether Placido- or elevation-based, which allows for detailed analysis of even irregular astigmatism, including the corneal periphery, which is invaluable. Aberrometers, essentially "super-auto refractors", allow the incorporation of additional data into the qualitative analysis of astigmatism. The correlation between these multiple preoperative data helps to differentiate between corneal and total astigmatism, to infer the lenticular astigmatism, and to integrate all of these data into the clinical decision-making process. Immediately preoperatively, the 0 and 180° axes are marked; then, with the aid of a special marker, the axis of alignment for the toric IOL is also marked. Once the cataract is removed, the toric IOL is injected and pre-aligned; the viscoelastic is carefully removed, particularly from between the IOL and posterior capsule, with the toric IOL being definitively aligned at this point. These alignment techniques represent a major advance, soon to be indispensible for toric IOL surgery, which will certainly continue to grow in the future. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  4. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    PubMed

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  5. Toric Intraocular Lens for Astigmatism Correction in Cataract Patients.

    PubMed

    Razmjoo, Hassan; Ghoreishi, Mohammad; Milasi, Azadeh Mohammadi; Peyman, Alireza; Jafarzadeh, Zahra; Mohammadinia, Mohadeseh; Kobra, Nasrollahi

    2017-01-01

    To assess the clinical consequences of AcrySof toric intraocular lens (IOL) and Hoya toric IOL implantation to correct preexisting corneal astigmatism in patients undergoing cataract surgery. In this study, we examined 55 eyes of 45 patients with at least 1.00 D corneal astigmatism who were scheduled for cataract surgery. After phacoemulsification, toric IOL was inserted and axis was aligned. We observed the patients, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, manifest refraction, and IOL axis alignment 6 months after surgery. After 6 months, the UDVA was 0.17 ± 0.17 logMAR in the AcrySof group and 0.17 ± 0.18 logMar in the Hoya group. More than 78% of eyes in the AcrySof group and 80% of eyes in the Hoya toric IOL achieved a UDVA of 20/40 or better. In the AcrySof group, the mean preoperative corneal astigmatism was 2.73 ± 0.92 D. The mean postoperative refractive astigmatism was 0.84 ± 0.63 D. In the Hoya group, the preoperative corneal astigmatism was 2.58 ± 0.76 D and the postoperative refractive astigmatism was 0.87 ± 0.66 D ( P < 0.05). The mean AcrySof IOL axis rotation was 1.88° ± 3.05°. In the Hoya group, the mean axis rotation was 1.53° ± 3.66°. All changes in visual and refractive data before and after surgery were statistically significant ( P < 0.05). There was no significant difference between the two groups regarding refractive and visual outcome after surgery ( P > 0.05 for all). Implantation of AcrySof toric IOL and Hoya toric IOL was an effective way to correct preexisting corneal astigmatism in cataract surgery.

  6. Outcomes of LASIK and PRK in previous penetrating corneal transplant recipients.

    PubMed

    Kovoor, Timmy A; Mohamed, Engy; Cavanagh, H Dwight; Bowman, R Wayne

    2009-09-01

    To evaluate the safety and efficacy of excimer laser refractive surgery in correcting refractive error in eyes that have undergone previous penetrating keratoplasty (PK). Twenty-three keratorefractive procedures on 16 eyes from 16 consecutive subjects were evaluated between 2002 and 2008. Each patient presented a previous history of a PK with subsequent postoperative myopia and astigmatism. Keratometric value, manifest refraction, best-corrected visual acuity, uncorrected visual acuity, and complications were determined. There were a total of 14 photorefractive keratectomy (PRK) procedures performed on 11 eyes and 9 laser in situ keratomileusis (LASIK) procedures performed on 5 eyes. In the PRK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -6.22 +/- 6.23 diopter and 5.23 +/- 2.26 D, respectively. The PRK postoperative manifest refractive spherical equivalent and cylindrical error were -3.61 +/- 4.23 D (P=0.25) and 3.21 +/- 1.78 D (P=0.02), respectively. In the LASIK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -3.05 +/- 3.29 D and 4.11 +/- 2.38 D, respectively. The LASIK postoperative manifest refractive spherical equivalent and cylindrical error were -1.51 +/- 2.02 D (P=0.24) and 2.08 +/- 1.26 D (P=0.03), respectively. There was a 2-line or greater improvement of uncorrected visual acuity in 8 of the 14 PRK treatments and 5 of the 9 LASIK treatments. There were two episodes of acute graft rejection. One of the episodes resolved with topical and oral corticosteroids, and the other episode required a repeat corneal transplantation. PRK and LASIK are effective tools in reducing surgically induced astigmatism after penetrating corneal transplantation in most patients in this case series. The reduction of astigmatism may allow improved contact lens or spectacle fitting to achieve best-corrected binocular visual acuity.

  7. Changes in shape and astigmatism of total, anterior, and posterior cornea after long versus short clear corneal incision cataract surgery.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hirata, Akira; Yoshimura, Koichi

    2018-01-01

    To compare changes in the shape and astigmatism of the total, anterior, and posterior cornea between eyes with long-length clear corneal incisions (CCIs) and eyes with short-length CCIs in cataract surgery. Hayashi Eye Hospital, Fukuoka, Japan. Prospective case series. Both eyes of patients having phacoemulsification with temporal CCIs were randomized to have a long-length (≥1.75 mm) or short-length (<1.75 mm) CCI. Corneal astigmatic changes were decomposed to vertical/horizontal (Jackson cross-cylinder, axes at 180 degrees and 90 degrees [J0]) and oblique changes (Jackson cross-cylinder, axes at 45 degrees and 135 degrees [J45]) using power vector analysis. Corneal shape changes were assessed using the average of the difference map on videokeratography 2 days and 2, 4, and 8 weeks postoperatively. The mean J0 and J45 values of the total cornea in the 120 eyes evaluated were significantly greater in the long CCI group than in the short CCI group at all follow-ups (P ≤ .0290). The videokeratography showed a wedge-shaped flattening in the total and anterior cornea and a steepening in the posterior cornea around the CCI 2 days postoperatively in both groups. This wound-related flattening of the total and anterior cornea rapidly reduced but persisted until 8 weeks, whereas the steepening of the posterior cornea disappeared within 4 weeks. These changes extended closer to the central cornea in the long CCI group than in the short CCI group. Corneal astigmatic changes were significantly greater after long CCI than after short CCI. The wound-related shape changes occurred immediately postoperatively but rapidly diminished. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Higher Order Aberration and Astigmatism in Children with Hyperopic Amblyopia.

    PubMed

    Choi, Seung Kwon; Chang, Ji Woong

    2016-02-01

    To investigate the changes in corneal higher-order aberration (HOA) during amblyopia treatment and the correlation between HOA and astigmatism in hyperopic amblyopia children. In this retrospective study, a total of 72 eyes from 72 patients ranging in age from 38 to 161 months were included. Patients were divided into two groups based on the degree of astigmatism. Corneal HOA was measured using a KR-1W aberrometer at the initial visit and at 3-, 6-, and 12-month follow-ups. Correlation analysis was performed to assess the association between HOA and astigmatism. A total of 72 patients were enrolled in this study, 37 of which were classified as belonging to the higher astigmatism group, while 35 were assigned to the lower astigmatism group. There was a statistically significant difference in success rate between the higher and lower astigmatism groups. In both groups, all corneal HOAs were significantly reduced during amblyopia treatment. When comparing the two groups, a significant difference in coma HOA at the 12-month follow-up was detected (p = 0.043). In the Pearson correlation test, coma HOA at the 12-month follow-up demonstrated a statistically significant correlation with astigmatism and a stronger correlation with astigmatism in the higher astigmatism group than in the lower astigmatism group (coefficient values, 0.383 and 0.284 as well as p = 0.021 and p = 0.038, respectively). HOA, particularly coma HOA, correlated with astigmatism and could exert effects in cases involving hyperopic amblyopia.

  9. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    PubMed Central

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  10. Effectiveness and confounding factors of penetrating astigmatic keratotomy in clinical practice

    PubMed Central

    Yen, Chu-Yu; Tseng, Gow-Lieng

    2018-01-01

    Abstract Rationale: Penetrating astigmatic keratotomy (penetrating AK) is a well-known method to correct corneal astigmatism but rarely be performed nowadays. This article reevaluated the clinical effectiveness and confounding factors of penetrating AK. Patient concerns: Penetrating AK has been introduced to serve as one alternative operation for astigmatism correction, and is thought to have the potential advantage of being more affordable and easy to perform. The purpose of our study is to evaluate the effectiveness and confounding factors of penetrating AK. Diagnoses: The chart of 95 patients with corneal astigmatism (range: 0.75–3.25 diopters [D]) who received penetrating AK from January 2014 to December 2016 was collected. The corneal astigmatism were measured by an autokeratometer (Topcon KR8100PA topographer-autorefractor), and repeated with manual keratometer in low reproducibility cases. Interventions: All patients received penetrating AK by an experienced ophthalmologist (Dr. Gow-Lieng Tseng, MD, PHD) in the operation room. Among which, 66 patients received penetrating AK with phacoemulsification simultaneously (group A), whereas 29 patients received penetrating AK at least 3 months after phacoemulsification (group B). After excluding the patients combined with other procedures or lost followed up, 79 patients are remaining for analysis. The outcome was evaluated by net correction, the difference between preoperative corneal astigmatism (PCA) and residual corneal astigmatism (RCA). Two sample t tests and Pearson test were used for effectiveness evaluation. For confounding factors, multivariate linear regression was used for statistical analysis. Outcomes: The mean preoperative and postoperative refractive cylinders were 1.97 ± 0.77 and 1.08 ± 0.64 D, respectively, in group A and 2.62 ± 1.05 and 1.51 ± 0.89 D in group B. There were no statistically significant differences in net correction between these two groups (0.9 ± 0.66 vs

  11. Anterior Corneal, Posterior Corneal, and Lenticular Contributions to Ocular Aberrations.

    PubMed

    Atchison, David A; Suheimat, Marwan; Mathur, Ankit; Lister, Lucas J; Rozema, Jos

    2016-10-01

    To determine the corneal surfaces and lens contributions to ocular aberrations. There were 61 healthy participants with ages ranging from 20 to 55 years and refractions -8.25 diopters (D) to +3.25 D. Anterior and posterior corneal topographies were obtained with an Oculus Pentacam, and ocular aberrations were obtained with an iTrace aberrometer. Raytracing through models of corneas provided total corneal and surface component aberrations for 5-mm-diameter pupils. Lenticular contributions were given as differences between ocular and corneal aberrations. Theoretical raytracing investigated influence of object distance on aberrations. Apart from defocus, the highest aberration coefficients were horizontal astigmatism, horizontal coma, and spherical aberration. Most correlations between lenticular and ocular parameters were positive and significant, with compensation of total corneal aberrations by lenticular aberrations for 5/12 coefficients. Anterior corneal aberrations were approximately three times higher than posterior corneal aberrations and usually had opposite signs. Corneal topographic centers were displaced from aberrometer pupil centers by 0.32 ± 0.19 mm nasally and 0.02 ± 0.16 mm inferiorly; disregarding corneal decentration relative to pupil center was significant for oblique astigmatism, horizontal coma, and horizontal trefoil. An object at infinity, rather than at the image in the anterior cornea, gave incorrect aberration estimates of the posterior cornea. Corneal and lenticular aberration magnitudes are similar, and aberrations of the anterior corneal surface are approximately three times those of the posterior surface. Corneal decentration relative to pupil center has significant effects on oblique astigmatism, horizontal coma, and horizontal trefoil. When estimating component aberrations, it is important to use correct object/image conjugates and heights at surfaces.

  12. Higher Order Aberration and Astigmatism in Children with Hyperopic Amblyopia

    PubMed Central

    Choi, Seung Kwon

    2016-01-01

    Purpose To investigate the changes in corneal higher-order aberration (HOA) during amblyopia treatment and the correlation between HOA and astigmatism in hyperopic amblyopia children. Methods In this retrospective study, a total of 72 eyes from 72 patients ranging in age from 38 to 161 months were included. Patients were divided into two groups based on the degree of astigmatism. Corneal HOA was measured using a KR-1W aberrometer at the initial visit and at 3-, 6-, and 12-month follow-ups. Correlation analysis was performed to assess the association between HOA and astigmatism. Results A total of 72 patients were enrolled in this study, 37 of which were classified as belonging to the higher astigmatism group, while 35 were assigned to the lower astigmatism group. There was a statistically significant difference in success rate between the higher and lower astigmatism groups. In both groups, all corneal HOAs were significantly reduced during amblyopia treatment. When comparing the two groups, a significant difference in coma HOA at the 12-month follow-up was detected (p = 0.043). In the Pearson correlation test, coma HOA at the 12-month follow-up demonstrated a statistically significant correlation with astigmatism and a stronger correlation with astigmatism in the higher astigmatism group than in the lower astigmatism group (coefficient values, 0.383 and 0.284 as well as p = 0.021 and p = 0.038, respectively). Conclusions HOA, particularly coma HOA, correlated with astigmatism and could exert effects in cases involving hyperopic amblyopia. PMID:26865804

  13. Simultaneous topography-guided PRK followed by corneal collagen cross-linking after lamellar keratoplasty for keratoconus.

    PubMed

    Spadea, Leopoldo; Paroli, Marino

    2012-01-01

    The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (-6.11 D ± 2.48, range -2.50 to -9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. After a mean 15 ± 6.5 (range 6-24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1-10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was -0.79 ± 2.09 (range +1 to -3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8-8.9) D. All the corneas remained clear (haze < 1). The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus.

  14. Progressive lenticular astigmatism in the clear lens.

    PubMed

    Tatham, Andrew; Prydal, Jeremy

    2008-03-01

    We describe a case of progressive lenticular astigmatism in a 53-year-old man with a clear lens. The patient acquired 5 diopters of lenticular astigmatism in his right eye over an 18-month period. The visual acuity was reduced to 6/60. Following phacoemulsification and intraocular lens implantation, the uncorrected visual acuity was 6/5. Progressive astigmatism is usually corneal in origin and in an otherwise healthy eye, significant lenticular astigmatism is rare. When lenticular astigmatism occurs, it is usually associated with a cortical cataract; however, astigmatism may precede the development of a clinically visible cataract.

  15. Reproducibility of corneal astigmatism measurements with a hand held keratometer in preschool children.

    PubMed Central

    Harvey, E M; Miller, J M; Dobson, V

    1995-01-01

    AIMS--To evaluate the overall accuracy and reproducibility of the Alcon portable autokeratometer (PAK) measurements in infants and young children. METHODS--The accuracy of the Alcon PAK in measuring toric reference surfaces (1, 3, 5, and 7 D) under various suboptimal measurement conditions was assessed, and the reproducibility of PAK measurements of corneal astigmatism in newborn infants (n = 5), children (n = 19, age 3-5 years), and adults (n = 14) was evaluated. RESULTS--Measurements of toric reference surfaces indicated (a) no significant effect of distance (17-30 mm) on accuracy of measurements, (b) no systematic relation between amount of toricity and accuracy of measurements, (c) no systematic relation between angle of measurement and accuracy, (d) no difference in accuracy of measurements when the PAK is hand held in comparison with when it is mounted, (e) no difference in accuracy of measurements when axis of toricity is oriented obliquely than when it is oriented horizontally, with respect to the PAK, and (f) a small positive bias (+0.16 D) in measurement of spherical equivalent. The PAK did not prove useful for screening newborns. However, measurements were successfully obtained from 18/19 children and 14/14 adults. There was no significant difference in median measurement deviation (deviation of a subject's five measurements from his/her mean) between children (0.21 D) and adults (0.13 D). CONCLUSIONS--The PAK produces accurate measurements of surface curvature under a variety of suboptimal conditions. Variability of PAK measurements in preschool children is small enough to suggest that it would be useful for screening for corneal astigmatism in young children. PMID:8534668

  16. Effect of Cycloplegia on Corneal Biometrics and Refractive State

    PubMed Central

    Bagheri, Abbas; Feizi, Mohadeseh; Shafii, Aliakbar; Faramarzi, Amir; Tavakoli, Mehdi; Yazdani, Shahin

    2018-01-01

    Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. Methods: In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Results: Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively). Conclusion: Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. PMID:29719636

  17. Effect of Cycloplegia on Corneal Biometrics and Refractive State.

    PubMed

    Bagheri, Abbas; Feizi, Mohadeseh; Shafii, Aliakbar; Faramarzi, Amir; Tavakoli, Mehdi; Yazdani, Shahin

    2018-01-01

    To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia ( P < 0.001). The astigmatism power did not significantly change ( P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant ( P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions ( P < 0.001 and P < 0.001, respectively). Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries.

  18. Evaluating internal and ocular residual astigmatism in Chinese myopic children.

    PubMed

    Liu, Yanlin; Cheng, Yong; Zhang, Yue; Zhang, Lu; Zhao, Mingwei; Wang, Kai

    2017-11-01

    To investigate the nature of internal astigmatism (IA) and ocular residual astigmatism (ORA) in Chinese myopic children and to identify factors that may influence IA and ORA. A total of 206 eyes of 206 myopic children (97 boys and 109 girls; 10.95 ± 2.2 years) were enrolled in this cross sectional study. Total ocular astigmatism (TOA), anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA) and total corneal astigmatism (TCA) were measured directly using either a Hartmann-Shack wavefront sensor or a Pentacam. IA and ORA were calculated by Fourier vector analyses (the definitions of IA and ORA are: IA = TOA - ACA - PCA, ORA = TOA - ACA). Spearman or Pearson correlation was adopted to detect multiple factors that may influence IA and ORA, which were then predicted by linear regressions. Modified compensation factors were applied to evaluate the inter-relationship between corneal astigmatism and ORA. While the mean values of IA and ORA were -0.52 DC × 94.8° and -0.63 DC × 93.0°, respectively, the percentage of ORA power over 1.00 D was as high as 28.64%. Full or under-compensation of ACA by ORA predominated in the enrolled subjects. The mean ORA J 0 and J 45 were -0.311 ± 0.236 and -0.032 ± 0.156 D, respectively, negatively correlated with the corresponding ACA components (J 0 : r = -0.276, J 45 : r = -0.616, p < 0.001). While age was not correlated with either IA or ORA (p > 0.1), the power of IA or ORA was correlated inversely with the axial length (IA: r = -0.193, p = 0.005; ORA: r = -0.169, p = 0.015) and positively with the spherical equivalent refraction (IA r = 0.195, p = 0.005; ORA r = 0.213, p = 0.002) and power of corneal astigmatism (IA-ACA: r = 0.302, IA-TCA: r = 0.368, ORA-ACA: r = 0.334, ORA-TCA: r = 0.293). Girls had larger IA powers than boys (0.741 ± 0.345 D vs 0.651 ± 0.340, p = 0.036). Full or under-compensation of ACA by ORA is common in Chinese myopic children, and the

  19. Simultaneous topography-guided PRK followed by corneal collagen cross-linking after lamellar keratoplasty for keratoconus

    PubMed Central

    Spadea, Leopoldo; Paroli, Marino

    2012-01-01

    Background The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. Methods The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (−6.11 D ± 2.48, range −2.50 to −9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. Results After a mean 15 ± 6.5 (range 6–24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1–10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was −0.79 ± 2.09 (range +1 to −3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8–8.9) D. All the corneas remained clear (haze < 1). Conclusion The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus. PMID:23152658

  20. Astigmatism Correction With Toric Intraocular Lenses in Descemet Membrane Endothelial Keratoplasty Triple Procedures.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2017-03-01

    To report the clinical efficacy of astigmatism correction with toric intraocular lenses (IOLs) in patients undergoing the Descemet membrane endothelial keratoplasty (DMEK) triple procedure and to evaluate the accuracy of the correction. Fifteen eyes of 10 patients who received cataract extraction, toric IOL placement, and DMEK surgery for Fuchs corneal dystrophy and cataracts were evaluated. The cylinder power of toric IOLs was determined by an online toric calculator with keratoscopy measurements obtained using Scheimpflug corneal imaging. Prediction errors were assessed as a difference vector between the anticipated minus postoperative residual astigmatism. At 10.1 ± 4.9 months postoperatively, 8/13 (61.5%) of eyes achieved uncorrected distance visual acuity better than 20/40. Mean best spectacle-corrected distance visual acuity (logMAR) improved from 0.21 ± 0.15 preoperatively to 0.08 ± 0.12 postoperatively (P < 0.01). The magnitude of refractive astigmatism was also significantly decreased from 2.23 ± 1.10 D (range 0.75-4.25 D) preoperatively to 0.87 ± 0.75 D (range 0.00-3.00 D) postoperatively (P < 0.01). In 1 eye with rotational misalignment by 43 degrees, we found no improvement of astigmatism. The prediction error of astigmatism at the corneal plane was 0.77 ± 0.54 D (range 0.10-1.77 D). Four eyes with preoperative "with-the-rule" corneal astigmatism had postoperative "against-the-rule" refractive astigmatism. For patients with Fuchs corneal dystrophy and cataracts, use of toric IOLs might be a valuable option in triple DMEK surgery. Additionally, care should be taken to prevent excessive IOL rotation.

  1. Postoperative corneal shape changes: microincision versus small-incision coaxial cataract surgery.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hayashi, Hideyuki

    2009-02-01

    To compare changes in corneal topography and in regular and irregular astigmatism after coaxial clear corneal microincision cataract surgery (MICS) and after coaxial small-incision cataract surgery (SICS). Hayashi Eye Hospital, Fukuoka, Japan. Induced corneal astigmatism was determined using vector analysis. The averaged corneal shape changes and degree of irregular astigmatism were examined using videokeratography preoperatively as well as 2 days and 1, 2, 4, and 8 weeks postoperatively. One hundred twenty eyes of 60 patients scheduled for phacoemulsification were evaluated. Sixty eyes had MICS (2.00 mm), and the 60 contralateral eyes had SICS (2.65 mm). The mean induced corneal astigmatism was significantly less in the MICS group than in the SICS group (P corneal flattening corresponding to the incision and coupled steepening around the flattened area 2 days postoperatively in both groups. The flattening and steepening gradually reduced to virtually the preoperative shape by 8 weeks; the changes were significantly less in the MICS group than in the SICS group. Of the irregular astigmatic components, higher-order irregularity was significantly less in the MICS group than in the SICS group up to 2 weeks postoperatively (P astigmatism, focal wound-related flattening of the peripheral cornea, and corneal surface irregularity were significantly less after coaxial MICS than after SICS.

  2. Management of postkeratoplasty astigmatism by paired arcuate incisions with compression sutures.

    PubMed

    Fares, Usama; Mokashi, Aashish A; Al-Aqaba, Mouhamed Ali; Otri, Ahmad Muneer; Miri, Ammar; Dua, Harminder Singh

    2013-04-01

    To analyse the efficacy of paired arcuate incisions and compression sutures technique in the management of post penetrating keratoplasty (PK) astigmatism. A paired arcuate incision with compression sutures procedure was used to treat 26 eyes with post-PK astigmatism ranging from 6.00 to 16.50 dioptres (D). The incisions were placed at the 7.0 mm optical zone inside the graft-host junction at a depth of 80% of corneal thickness. A 45° paired arc length was planned for eyes with preoperative astigmatism between 6D and 9D, and a 60° paired arc length was planned for eyes with preoperative astigmatism of >9D. At 3 months, corneal topography and refraction was performed and suture(s) removed if indicated. Net and vector astigmatism changes were calculated to determine the efficacy of the procedure. The indications for PK included keratoconus, Fuch's endothelial dystrophy, pseudophakic bullous keratopathy and corneal scar. There was a statistically significant reduction in the mean magnitude of astigmatism from 9.66 ± 2.90D preoperatively to 4.37 ± 2.53D postoperatively in the whole group. The mean decrease in the astigmatism was 4.37 ± 2.05D (58.4%) and 6.23 ± 3.63D (52.6%) in patients with 6-9D and >9D, respectively. Vector power calculations also showed a significant astigmatism reduction in all groups. The safety and efficacy indices were 1.40 and 0.28, respectively. Manual astigmatic keratotomy is a viable technique with relatively good safety and efficacy outcomes. Based on the results we propose that increasing the arc length to a minimum of 60° for astigmatism of 6-9D, and to 75° for astigmatism >9D, is likely to have a greater beneficial effect.

  3. Toric intraocular lens implantation versus astigmatic keratotomy to correct astigmatism during phacoemulsification.

    PubMed

    Titiyal, Jeewan S; Khatik, Mukesh; Sharma, Namrata; Sehra, Sri Vatsa; Maharana, Parfulla K; Ghatak, Urmimala; Agarwal, Tushar; Khokhar, Sudarshan; Chawla, Bhavana

    2014-05-01

    To compare toric intraocular lens (IOL) implantation and astigmatic keratotomy (AK) in correction of astigmatism during phacoemulsification. Tertiary care hospital. Prospective randomized trial. Consecutive patients with visually significant cataract and moderate astigmatism (1.25 to 3.00 diopters [D]) were randomized into 2 groups. Temporal clear corneal 2.75 mm phacoemulsification with toric IOL implantation was performed in the toric IOL group and with 30-degree coupled AK at the 7.0 mm optic zone in the keratotomy group. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, keratometry, topography, central corneal thickness, and endothelial cell density were evaluated preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. The study enrolled 34 eyes (34 patients), 17 in each group. There was no difference in UDVA or CDVA between the 2 groups at any follow-up visit. The mean preoperative and postoperative refractive cylinder was 2.00 D ± 0.49 (SD) and 0.33 ± 0.17 D, respectively, in the toric IOL group and 1.95 ± 0.47 D and 0.57 ± 0.41 D, respectively, in the keratotomy group (P=.10). The mean residual astigmatism at 3 months was 0.44 ± 1.89 @ 160 in the toric IOL group and 0.77 ± 1.92 @ 174 in the keratotomy group (P=.61). All eyes in the toric IOL group and 14 eyes (84%) in the keratotomy group achieved a residual refractive cylinder of 1.00 D or less (P=.17). Toric IOL implantation was comparable to AK in eyes with moderate astigmatism having phacoemulsification. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Variation of axial and oblique astigmatism with accommodation across the visual field

    PubMed Central

    Liu, Tao; Thibos, Larry N.

    2017-01-01

    In this study we investigated the impact of accommodation on axial and oblique astigmatism along 12 meridians of the central 30° of visual field and explored the compensation of corneal first-surface astigmatism by the remainder of the eye's optical system. Our experimental evidence revealed no systematic effect of accommodation on either axial or oblique astigmatism for two adult populations (myopic and emmetropic eyes). Although a few subjects exhibited systematic changes in axial astigmatism during accommodation, the dioptric value of these changes was much smaller than the amount of accommodation. For most subjects, axial and oblique astigmatism of the whole eye are both less than for the cornea alone, which indicates a compensatory role for internal optics at all accommodative states in both central and peripheral vision. A new method for determining the eye's optical axis based on visual field maps of oblique astigmatism revealed that, on average, the optical axis is 4.8° temporal and 0.39° superior to the foveal line-of-sight in object space, which agrees with previous results obtained by different methodologies and implies that foveal astigmatism includes a small amount of oblique astigmatism (0.06 D on average). Customized optical models of each eye revealed that oblique astigmatism of the corneal first surface is negligible along the pupillary axis for emmetropic and myopic eyes. Individual variation in the eye's optical axis is due in part to misalignment of the corneal and internal components that is consistent with tilting of the crystalline lens relative to the pupillary axis. PMID:28362902

  5. Lack of oblique astigmatism in the chicken eye.

    PubMed

    Maier, Felix M; Howland, Howard C; Ohlendorf, Arne; Wahl, Siegfried; Schaeffel, Frank

    2015-04-01

    Primate eyes display considerable oblique off-axis astigmatism which could provide information on the sign of defocus that is needed for emmetropization. The pattern of peripheral astigmatism is not known in the chicken eye, a common model of myopia. Peripheral astigmatism was mapped out over the horizontal visual field in three chickens, 43 days old, and in three near emmetropic human subjects, average age 34.7years, using infrared photoretinoscopy. There were no differences in astigmatism between humans and chickens in the central visual field (chicks -0.35D, humans -0.65D, n.s.) but large differences in the periphery (i.e. astigmatism at 40° in the temporal visual field: humans -4.21D, chicks -0.63D, p<0.001, unpaired t-test). The lack of peripheral astigmatism in chicks was not due to differences in corneal shape. Perhaps related to their superior peripheral optics, we found that chickens had excellent visual performance also in the far periphery. Using an automated optokinetic nystagmus paradigm, no difference was observed in spatial visual performance with vision restricted to either the central 67° of the visual field or to the periphery beyond 67°. Accommodation was elicited by stimuli presented far out in the visual field. Transscleral images of single infrared LEDs showed no sign of peripheral astigmatism. The chick may be the first terrestrial vertebrate described to lack oblique astigmatism. Since corneal shape cannot account for the difference in astigmatism in humans and chicks, it must trace back to the design of the crystalline lens. The lack of peripheral astigmatism in chicks also excludes a role in emmetropization. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Analysis of age-dependence of the anterior and posterior cornea with scheimpflug imaging.

    PubMed

    Nemeth, Gabor; Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo

    2013-05-01

    To assess keratometric and higher-order aberrations of the anterior and posterior cornea and their age-related changes. This study investigated one healthy eye of 227 patients (mean age: 55.15 ± 21.2 years; range: 16 to 90 years; 135 right eyes, 92 left eyes). Images were captured from each eye with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) using automatic mode. Keratometric, astigmatism data, and corneal higher-order aberrations were analyzed. With respect to laterality, no deviance was found in any of the parameters (P > .05). Mean refractive error was 0.52 ± 0.23 diopters. The level of astigmatism decreased significantly with advancing age for both the anterior and posterior corneal surfaces (P < .05). The overall root mean square of the higher-order aberration increased continuously with age (r = 0.517; P < .01), which can be explained by the combined effect of the increased in both the anterior and posterior corneal root mean square higher-order aberrations. Of the higher-order aberrations, the constant increase of the primary and secondary spherical aberration with aging (P < .01) is caused by the spherical aberration growth of the anterior surface. Apart from these, only the vertical coma aberration of the posterior surface and the vertical trefoil aberrations of both the anterior and posterior surfaces showed a significantly positive correlation with aging (P < .05). Corneal astigmatism showed a significant decrease with aging. Of the higher-order aberrations, primary and secondary spherical aberrations, vertical coma, and vertical trefoil significantly increase with age, whereas other higher-order aberrations show no correlation with aging. Copyright 2013, SLACK Incorporated.

  7. Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Tomida, Daisuke; Yamaguchi, Takefumi; Ogawa, Akiko; Hirayama, Yumiko; Shimazaki-Den, Seika; Satake, Yoshiyuki; Shimazaki, Jun

    2015-07-01

    To compare short-term outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) using a graft prepared with either a femtosecond laser or a microkeratome. Thirty-eight patients underwent DSAEK with grafts prepared with either a femtosecond laser (f-DSAEK; 21 eyes) or a microkeratome (m-DSAEK; 17 eyes). Visual acuity, endothelial cell density, regular astigmatism and irregular astigmatism were compared between the two groups preoperatively and at 1, 3, and 6 months post-operatively. Fourier analysis was conducted to calculate astigmatism of the anterior and posterior surfaces, and total cornea, using anterior segment optical coherence tomography (AS-OCT). Visual acuity (logMAR) improved from 1.20 ± 0.60 to 0.43 ± 0.25 after m-DSAEK (P < 0.001) and from 1.20 ± 0.57 to 0.77 ± 0.33 after f-DSAEK (P = 0.0028) at 6 months following DSAEK. Visual acuity after m-DSAEK was significantly better than after f-DSAEK at 1, 3, and 6 months (P < 0.05). AS-OCT corneal images revealed greater irregularities on the posterior surfaces of f-DSAEK grafts compared to m-DSAEK grafts. Irregular astigmatism of the total cornea and the posterior surface was significantly larger after f-DSAEK than after m-DSAEK, although there was no significant difference in irregular astigmatism of the anterior surface at 6 months. Postoperative visual acuity was significantly correlated with the postoperative irregular astigmatism of the total cornea (r = 0.6657 and P < 0.001) and the anterior (r = 0.416, P = 0.016) and posterior surfaces (r = 0.7046, P < 0.001). Visual outcomes after f-DSAEK were poor compared to conventional m-DSAEK due to an increase in irregular astigmatism caused by posterior surface irregularities.

  8. Astigmatism and biometric optic components of diode laser-treated threshold retinopathy of prematurity at 9 years of age

    PubMed Central

    Yang, C-S; Wang, A-G; Shih, Y-F; Hsu, W-M

    2013-01-01

    Purpose To assess the prevalence of astigmatism and its relationship with biometric optic components in preterm school children with diode laser-treated threshold retinopathy of prematurity (ROP). Methods A prospective, cross-sectional study in which cycloplegic keratometry, refraction, and ultrasound biometric measurement of optic components were performed on 24 consecutive preterm children with diode laser-treated threshold ROP at the age of 9 years. The study results were compared with data on 1021 age-matched full-term control children from a national survey. Results The laser-treated eyes had a mean astigmatism of 3.47 D, with a mean spherical equivalent of −4.49 D. Of the 46 eyes studied, 98% of eyes showed astigmatism ≥0.5 D and 50% had high astigmatism (>3.0 D). Most astigmatic eyes (97.7%) showed with-the-rule astigmatism, with the mean plus cylinder axis at 89.30o. Further correlation analysis showed the astigmatism in refraction was highly correlated with the corneal astigmatism (r=0.921, P<0.001) and the vertical corneal curvature (r=0.405, P=0.005). There was significantly steeper vertical corneal curvature (P=0.003) and flatter horizontal corneal curvature (P=0.031) in eyes with laser-treated ROP when compared with age-matched full-term controls. The eyes with laser-treated ROP also show significantly thicker lens (3.93 mm) and shallower anterior chamber depth (ACD; 2.92 mm) than full-term controls (P<0.001). Conclusions There is significantly higher prevalence and greater magnitude of astigmatism in eyes with laser-treated threshold ROP compared with full-term controls. The steeper vertical corneal curvature component contributes to the increased astigmatism in eyes with laser-treated ROP. PMID:23222565

  9. Influence of internal optical astigmatism on the correction of myopic astigmatism by LASIK.

    PubMed

    Qian, Yi-Shan; Huang, Jia; Liu, Rui; Chu, Ren-Yuan; Xu, Ye; Zhou, Xing-Tao; Hoffman, Matthew R

    2011-12-01

    To investigate the influence of the origin of astigmatism on the correction of myopic astigmatism by LASIK. A retrospective study was conducted of the records of 192 patients (192 eyes) undergoing LASIK for correction of myopia and myopic astigmatism from January to September 2010. Ocular residual astigmatism (ORA) and lenticular astigmatism (LA) were determined by vector analysis using objective refraction and Pentacam (Oculus Optikgeräte GmbH) imaging of both corneal surfaces. Patients were divided into two groups according to ORA (high ORA group: ORA/preoperative refractive astigmatism >1; normal ORA group: ORA/preoperative refractive astigmatism ≤ 1) and LA (high LA group: LA/preoperative refractive astigmatism >1; normal LA group: LA/preoperative refractive astigmatism ≤ 1). Procedural efficacy was compared between those eyes with and without a significant amount of internal optical astigmatism using index of success. Mean preoperative vectors for the astigmatism of the anterior cornea, posterior cornea, and lens were -1.33 × 3.0°, -0.33 × 95.3°, and -0.27 × 103.3°, respectively. Mean indices of success in the high and low ORA groups were 1.75 and 0.59, respectively (t=7.81, P<.001). Mean indices of success in the high and low LA groups were 2.07 and 0.70, respectively (t=12.36, P<.001). The higher indices of success in the high ORA and high LA groups suggest a lower efficacy of LASIK in treating astigmatism primarily located intraocularly. Myopic LASIK is less effective in correcting astigmatism when astigmatism is mainly located at the internal optics. Topography and refractive value should be incorporated in the treatment of patients when a significant amount of internal optical astigmatism is detected preoperatively.

  10. The Effects of Surgical Factors on Postoperative Astigmatism in Patients Enrolled in the Infant Aphakia Treatment Study (IATS)

    PubMed Central

    Wall, Palak B.; Lee, Jason A.; Lynn, Michael; Lambert, Scott R.; Traboulsi, Elias I.

    2015-01-01

    Purpose To evaluate the impact of surgical factors such as incision type, number of sutures, and technique of closure on postoperative astigmatism in infants undergoing cataract extraction with or without intraocular lens implantation. Methods The IATS is a multicenter (n=12) clinical trial in which 114 infants with unilateral congenital cataracts were randomized to undergo cataract extraction with intraocular lens (IOL) placement or contact lens aphakic correction. Surgical videos were reviewed with regard to incision type and location, whether the incision was extended, the number of sutures placed, and technique of closure. Corneal astigmatism was measured using a handheld keratometer prior to surgery and at 1 year of age. Results Corneal astigmatism decreased from a mean of 1.92 D at baseline to 1.62 D at age 1 year in the CL group, but remained almost unchanged from 2.00 D to 2.09 D in the IOL group (p=0.023). There was no statistical difference between the amount of corneal astigmatism irrespective of incision type (p=0.214) and no increase in astigmatism with extension of the incision to facilitate IOL placement (p=0.849) at 1 year. The number of sutures and technique of closure did not influence the amount of astigmatism at 1 year. Conclusions At the age of one year following cataract extraction in infants, contact lens correction and the lack of IOL placement are associated with a significant decrease in postoperative corneal astigmatism compared to intraocular lens placement. No other surgical factors considered in this study had a statistically significant impact on corneal astigmatism. PMID:25266831

  11. LASIK for spherical refractive myopia: effect of topographic astigmatism (ocular residual astigmatism, ORA) on refractive outcome.

    PubMed

    Frings, Andreas; Richard, Gisbert; Steinberg, Johannes; Skevas, Christos; Druchkiv, Vasyl; Katz, Toam; Linke, Stephan J

    2015-01-01

    In eyes with a preoperative plano refractive cylinder, it would appear that there is no rationale for astigmatic treatment. The aim of this retrospective, cross-sectional data analysis was to determine the amount of topographic astigmatism in refractive plano eyes that results in reduced efficacy after myopic laser in situ keratomileusis (LASIK). This study included 267 eyes from 267 consecutive myopic patients with a refractive plano cylinder. Receiver operating characteristic analysis was used to find the cut-off values of preoperative ocular residual astigmatism (= topographic astigmatism) that can best discriminate between groups of efficacy and safety indices in preoperative plano refractive cylinder eyes. Preoperative ocular residual astigmatism (ORA) (or topographic astigmatism) of ≤0.9 diopters (D) resulted in an efficacy index of at least 0.8 statistically significantly more frequently than eyes with a preoperative ORA of >0.9 D. Eyes with a high ORA preoperatively also had a high ORA postoperatively. Regression analysis showed that each diopter of preoperative ORA reduced efficacy by 0.07. A preoperative corneal astigmatism of ≥0.9 D could (partially) be taken into account in the LASIK design, even if the subjective refractive astigmatism is neutral.

  12. [Predictability of the corneal flap creation with the femtosecond laser in LASIK].

    PubMed

    Mai, Zhi-bin; Liu, Su-bing; Nie, Xiao-li; Sun, Hong-xia; Xin, Bao-li; Tang, Xiu-xia

    2012-05-01

    To observe the predictability of corneal flap creation with the FEMTO LDV femtosecond laser and analyze preliminarily the factors correlating to the thickness and diameter of the flap . It was a study of serial cases. 260 eyes of 130 consecutive patients were treated with the FEMTO LDV. The eyes were assigned to two groups according to intended flap thickness, 110 µm (208 eyes) and 90 µm (52 eyes). Intended flap diameter varied from 8.5 to 9.5 mm. Difference analysis of flap diameter and intended diameter as well as flap thickness and intended thickness were made. The data was analyzed with SPSS to sum up a multiple stepwise regression formula that could express their quantitative relationship. The 90 µm flap group had a average flap thickness of (95.12 ± 7.65) µm, while for the 110 µm group the average flap thickness was (104.81 ± 3.09) µm. The difference between right and left eyes was not statistically significant (t(110 µm) = -1.223, t(90 µm) = -1.343, P > 0.05). Corneal flap thickness was inversely correlated with flap diameter (r(110 µm) = -0.143, r(90 µm) = -0.315, P < 0.05), but was not related to preoperative patient age, corneal thickness, keratometric value K or intraocular pressure (r(110 µm) = -0.160, 0.054, -0.011, -0.363; r(90 µm) = 0.024, 0.074, -0.212, -0.434, all P > 0.05). Corneal flap diameter was positively correlated with preoperative corneal keratometric value K and thickness (P < 0.001, P < 0.05). Multiple stepwise regression analysis showed flap diameter was an influencing factor for flap thickness. Preoperative corneal keratometric value K and thickness were influencing factors for flap diameter. The LASIK flap creation with the FEMTO LDV laser has relatively good predictability. Flap diameter is an influencing factor for flap thickness.

  13. Morphologic features and surgically induced astigmatism of femtosecond laser versus manual clear corneal incisions.

    PubMed

    Zhu, Sha; Qu, Naibin; Wang, Wei; Zhu, Yanan; Shentu, Xingchao; Chen, Peiqing; Xu, Wen; Yao, Ke

    2017-11-01

    To compare the morphologic features and surgically induced astigmatism (SIA) between laser and manual clear corneal incisions (CCIs) after femtosecond laser-assisted cataract surgery. Eye Center, 2nd Affiliated Hospital, Medical College of Zhejiang University, Hangzhou, China. Prospective case series. Patients had femtosecond laser-assisted cataract surgery with a CCI created with the laser or manually after random allocation. The corrected distance visual acuity, corneal topography, and anterior segment optical coherence tomography were assessed at the 1-day, 1-week, 1-month, and 3-month follow-ups. The laser CCI group comprised 45 eyes and the manual CCI group, 48 eyes. The SIA was significantly lower in the manual CCI group than the laser CCI group at all visits (P < .05). At the 1-day and 1-week follow-ups, the mean CCI thickness was significantly smaller in the manual CCI group (P < .05). In the laser CCI group, the perpendicular linear distance between the external wound opening and the corneal vertex central line was statistically shorter than in the manual CCI group (P < .05). At 3 months, the SIA was correlated with the perpendicular linear distance with a Pearson correlation coefficient of -0.341 (P = .001). Femtosecond laser-created CCIs for cataract surgery caused more SIA than manually created CCIs, which could have resulted from inaccurate or uncertain corneal incision positioning of the femtosecond machine. Manual creation of CCIs is recommended in femtosecond laser-assisted cataract surgery until the locating system for the femtosecond laser incision is updated. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. The effects of surgical factors on postoperative astigmatism in patients enrolled in the Infant Aphakia Treatment Study (IATS).

    PubMed

    Wall, Palak B; Lee, Jason A; Lynn, Michael J; Lambert, Scott R; Traboulsi, Elias I

    2014-10-01

    To evaluate the effect of surgical factors on postoperative astigmatism in infants undergoing cataract extraction with or without intraocular lens (IOL) implantation. The Infant Aphakia Treatment Study is a multicenter clinical trial in which 114 infants with unilateral congenital cataracts were randomized to undergo cataract extraction with IOL placement or contact lens aphakic correction. Surgical videos were reviewed with regard to incision type and location, whether the incision was extended, the number of sutures placed, and technique of closure. Corneal astigmatism was measured using a handheld keratometer prior to surgery and at 1 year of age. Corneal astigmatism decreased from a mean of 1.92 D at baseline to 1.62 D at age 1 year in the contact lens group but remained almost unchanged from 2.00 D to 2.09 D in the IOL group (P = 0.023). There was no statistical difference between the amount of corneal astigmatism with regard to incision type (P = 0.214) and no increase in astigmatism with extension of the incision to facilitate IOL placement (P = 0.849) at 1 year. The number of sutures and technique of closure did not influence the amount of astigmatism at 1 year. At the age of 1 year following cataract extraction in infants, contact lens correction and the lack of IOL placement are associated with a significant decrease in postoperative corneal astigmatism compared to IOL placement. No other surgical factors considered in this study had a statistically significant effect on corneal astigmatism. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  15. Scheimpflug topographical changes after Femtosecond LASIK for mixed astigmatism - theoretical aspects and case study.

    PubMed

    Tabacaru, Bogdana; Stanca, Horia Tudor

    2017-01-01

    Objective: To evaluate the corneal topographical changes after Femtosecond-LASIK surgery in eyes with mixed astigmatism. Methods: We present the analysis of the corneal Scheimpflug topographies of a patient treated with Femtosecond-LASIK technique for bilateral mixed astigmatism. Results: Three-dimensional reconstruction maps and differential anterior curvature maps were used to demonstrate the ablation profile and its stability in time. Conclusions: Visual and refractive results were very good after surgery, being topographically confirmed by the corneal reshaping which was performed as planned, the achieved ablation being stable during the one-year follow-up period.

  16. LASIK for Spherical Refractive Myopia: Effect of Topographic Astigmatism (Ocular Residual Astigmatism, ORA) on Refractive Outcome

    PubMed Central

    Frings, Andreas; Richard, Gisbert; Steinberg, Johannes; Skevas, Christos; Druchkiv, Vasyl; Katz, Toam; Linke, Stephan J.

    2015-01-01

    Purpose In eyes with a preoperative plano refractive cylinder, it would appear that there is no rationale for astigmatic treatment. The aim of this retrospective, cross-sectional data analysis was to determine the amount of topographic astigmatism in refractive plano eyes that results in reduced efficacy after myopic laser in situ keratomileusis (LASIK). Methods This study included 267 eyes from 267 consecutive myopic patients with a refractive plano cylinder. Receiver operating characteristic analysis was used to find the cut-off values of preoperative ocular residual astigmatism (= topographic astigmatism) that can best discriminate between groups of efficacy and safety indices in preoperative plano refractive cylinder eyes. Results Preoperative ocular residual astigmatism (ORA) (or topographic astigmatism) of ≤0.9 diopters (D) resulted in an efficacy index of at least 0.8 statistically significantly more frequently than eyes with a preoperative ORA of >0.9 D. Eyes with a high ORA preoperatively also had a high ORA postoperatively. Regression analysis showed that each diopter of preoperative ORA reduced efficacy by 0.07. Conclusion A preoperative corneal astigmatism of ≥0.9 D could (partially) be taken into account in the LASIK design, even if the subjective refractive astigmatism is neutral. PMID:25875476

  17. Preliminary study of the association between corneal histocytological changes and surgically induced astigmatism after phacoemulsification.

    PubMed

    Du, Xing; Zhao, Guiqiu; Wang, Qing; Yang, Xian; Gao, Ang; Lin, Jing; Wang, Qian; Xu, Qiang

    2014-11-20

    Surgically induced astigmatism (SIA) was one of the factors that influences the desirable refractive outcome, and it was related to the length, type, location, structure of the incision and to the suture closure technique, etc. The aim was to evaluate the association of corneal histocytological changes with SIA after phacoemulsification. The study enrolled 68 cases of cataract patient (68 eyes). Corneal histocytological parameters at corneal incision, central cornea and contralateral incision obtained by confocal microscope through focusing (CMTF) were compared preoperatively and 1 week, 2 weeks, 1 month, 3 months and 6 months postoperatively. These biometric parameters included the endothelial cell density, keratocyte density of posterior stromal layer, and the morphological changes. SIA was calculated by Jaffe's vector analysis. 1 From preoperatively to 1 week, 2 weeks, 1 month, 3 months and 6 months postoperatively, the endothelail cell density was decreased significantly (p < 0.05). Keratocyte density of posterior stroma layer was increased significantly only at 1 week, 2 weeks, 1 month, 3 months postoperatively (p <0.05), but not statistically significant (p = 0.173) at 6 months postoperatively compared to preoperative values. 2 The histocytological observations indicated that the morphology changed significantly postoperatively at the corneal incision, including the cell absent area, wave-like area, dot-like and mass-like hyperreflection, stripe-like absent area, in the endothelial layer, and the keratocyte activation, microfolds, irregular hyporeflective or hyperreflective belt, and a little dot-like hyperreflection in the posterior stroma layer. 3 The reduction of the endothelial cell density at the corneal incision at 1 week, 2 weeks, 1 month postoperatively, were positively correlated with SIA (P1 week = 0.003, P2 weeks = 0.003, P1 month = 0.032), while others were not associated with SIA statistically. The reduction of endothelail cell density and the

  18. Astigmatism in Monkeys with Experimentally Induced Myopia or Hyperopia

    PubMed Central

    KEE, CHEA-SU; HUNG, LI-FANG; QIAO-GRIDER, YING; RAMAMIRTHAM, RAMKUMAR; SMITH, EARL L.

    2006-01-01

    Purpose Astigmatism is the most common ametropia found in humans and is often associated with large spherical ametropias. However, little is known about the etiology of astigmatism or the reason(s) for the association between spherical and astigmatic refractive errors. This study examines the frequency and characteristics of astigmatism in infant monkeys that developed axial ametropias as a result of altered early visual experience. Methods Data were obtained from 112 rhesus monkeys that experienced a variety of lens-rearing regimens that were intended to alter the normal course of emmetropization. These visual manipulations included form deprivation (n = 13); optically imposed defocus (n = 48); and continuous ambient lighting with (n = 6) or without optically imposed defocus (n = 6). In addition, data from 19 control monkeys and 39 infants reared with an optically imposed astigmatism were used for comparison purposes. The lens-rearing period started at approximately 3 weeks of age and ended by 4 to 5 months of age. Refractive development for all monkeys was assessed periodically throughout the treatment and subsequent recovery periods by retinoscopy, keratometry, and A-scan ultrasonography. Results In contrast to control monkeys, the monkeys that had experimentally induced axial ametropias frequently developed significant amounts of astigmatism (mean refractive astigmatism = 0.37 ± 0.33 D [control] vs. 1.24 ± 0.81 D [treated]; two-sample t-test, p < 0.0001), especially when their eyes exhibited relative hyperopic shifts in refractive error. The astigmatism was corneal in origin (Pearson’s r; p < 0.001 for total astigmatism and the JO and J45 components), and the axes of the astigmatism were typically oblique and bilaterally mirror symmetric. Interestingly, the astigmatism was not permanent; the majority of the monkeys exhibited substantial reductions in the amount of astigmatism at or near the end of the lens-rearing procedures. Conclusions In infant monkeys

  19. Outcome of corneal and laser astigmatic axis alignment in photoastigmatic refractive keratectomy.

    PubMed

    Farah, S G; Olafsson, E; Gwynn, D G; Azar, D T; Brightbill, F S

    2000-12-01

    To compare the refractive results of laser astigmatic treatment in eyes in which the astigmatic axes of the eye and laser are aligned by limbal marking at the 6 o'clock position and in eyes that are not marked. University Hospital and Clinics, Madison, Wisconsin, USA. This retrospective study comprised 143 eyes that had photoastigmatic refractive keratectomy with the VISX Star excimer laser. The eyes were divided into marked (G1) and unmarked (G2) groups. Based on the preoperative astigmatism, each group was subdivided into low astigmatism (astigmatism (>/=1.25 D). Early postoperative manifest refractions (1.0 to 2.5 months) were analyzed. The Alpins vector analysis method was used to calculate the target induced astigmatism, surgically induced astigmatism, difference vector (DV), magnitude of error (ME), angle of error (AE), and index of success (IS). There was no significant difference between the groups in DV, ME, and IS. When the subgroups were analyzed, the DV and ME were comparable; the IS in the G1 high astigmatism subgroup was significantly better than that in the G2 high astigmatism subgroup (0.22 +/- 0.08 and 0.29 +/- 0.04, respectively; P <.0001). There was comparable scatter of AE values; 30% and 36% in G1 and G2, respectively, had an AE of 0. Similar scatter was observed in the subgroups. Of the eyes that had an AE of 0, 90% and 43% in the high astigmatism subgroups of G1 and G2, respectively (P <.05), had full correction of astigmatism. Limbal marking and subsequent eye and laser astigmatic axis alignment improved the refractive outcome of laser astigmatic treatment of >/=1.25 D. A preliminary report of an ongoing prospective randomized study of eyes that had laser in situ keratomileusis is included.

  20. Calculation of the change in corneal astigmatism following cataract extraction.

    PubMed

    Cravy, T V

    1979-01-01

    Obtaining a minimal amount of postoperative astigmatism following cataract surgery is becoming increasingly important. One aspect of the patient's surgery which should not be overlooked is the preoperative keratometry which provides a basis for preoperative planning of surgical technique to be used and a point of reference for determining the amount of change in astigmatism produced by the surgery. Analysis of the surgically induced change in astigmatism using the calculations described in this paper will allow the surgeon to evaluate his own techniques and to maximize his potential for obtaining consistently good postoperative astigmatic results without the need for suture removal. The method presented is based upon concepts in common use in surgical ophthalmology and requires only simple mathematical procedures, familiar to all with a background in algebra and trigonometry.

  1. Combined laser in situ keratomileusis and prophylactic high-fluence corneal collagen crosslinking for high myopia: two-year safety and efficacy.

    PubMed

    Kanellopoulos, Anastasios John; Asimellis, George

    2015-07-01

    To evaluate the safety, efficacy, and refractive and keratometric stability of myopic femtosecond laser in situ keratomileusis (LASIK) with concurrent prophylactic high-fluence corneal collagen crosslinking (CXL) compared with the outcomes of standard femtosecond LASIK. Private clinical practice, Athens, Greece. Consecutive randomized prospective comparative study. Eyes that had myopic LASIK or myopic LASIK with concurrent high-fluence CXL were evaluated preoperatively and up to 2 years postoperatively for manifest refraction spherical equivalent (MRSE), refractive astigmatism, visual acuity, corneal keratometry (K), and endothelial cell count. One hundred forty consecutive eyes had myopic LASIK; 65 of the eyes were treated additionally with CXL. In the LASIK-CXL eyes, the mean postoperative MRSE was -0.18 diopter (D) ± 17.0 (SD) from -6.67 ± 2.14 D preoperatively. The postoperative flat K was 37.67 D from 43.92 D, and the steep K was 38.38 D from 45.15 D. The correlation coefficient of SE correction predictability was 0.975. In the LASIK-only eyes, the mean postoperative MRSE was -0.32 ± 0.24 D from -5.49 ± 1.99 D preoperatively. The flat K was 38.04 D from 43.15 D, and the steep K was 38.69 D from 44.03 D. The correlation coefficient of SE correction predictability was 0.968. The differences between the 2 groups at the 20/20 and 20/25 levels were statistically significant (P = .045 and P = .039, respectively). Two-year results indicate that the application of prophylactic CXL concurrently with high-myopic LASIK appears to improve refractive and keratometric stability, presumably by affecting corneal biomechanical properties. Dr. Kanellopoulos is a consultant to Alcon Surgical, Inc., Wavelight Laser Technologie AG, Allergan, Inc., Avedro, Inc., and i-Optics Corp. Dr. Asimellis has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Long-Term Observation of Coexistence of Posterior Polymorphous Corneal Dystrophy, Resultant High Myopia and Nonkeratoconic Developing Corneal Astigmatism: A Case Report of 7-Year Tracking in a Chinese Boy.

    PubMed

    Shen, Jianqin; Chixin, Du; Gu, Yangshun

    2015-06-01

    Posterior polymorphous corneal dystrophy (PPCD) is an extremely rare, bilateral, and inherited disorder, which affects the corneal endothelium and Descemet's membrane. Few PPCD cases in Chinese patients have been published so far. As far as we know, there are few studies which focused on the associations between PPCD and high myopia either. Here we report a rare case of coexistence of posterior polymorphous corneal dystrophy, resultant high myopia and with-the-rule developing corneal astigmatism in a young Chinese boy. A 6-year-old boy was first referred to our department 7 years ago, complaining of bilateral poor vision. Examinations of both eyes including ophthalmologic examination, cycloplegic refraction examination, confocal microscopy findings, and corneal topography were performed. Bilateral small aggregates of vesicular lesions and patchy hyperreflectivity were observed at the level of the Descemet's membrane on confocal microscopy, which is consistent with typical PPCD. Optometry and corneal topography examinations showed a resultant high myopia. Ocular examinations were performed annually to follow up with the patient in the past 7 years. The corneal lesions remained stable whereas an axial elongation and a sharp increase in both spherical and cylindrical equivalent power were observed. Close follow-ups including thorough scrutiny of the endothelium and systematic ocular ancillary examinations are essential for patients with PPCD. The pathological coexistence of PPCD and high myopia in our case is possibly due to a shared etiological pathway or genetic background. Advanced genetic analysis on similar cases is expected if more samples can be provided.

  3. Effects of Optically Imposed Astigmatism on Early Eye Growth in Chicks

    PubMed Central

    Chu, Chin Hung Geoffrey; Kee, Chea Su

    2015-01-01

    Purpose To determine the effects of optically imposed astigmatism on early eye growth in chicks. Methods 5-day-old (P5) White Leghorn chicks were randomly assigned to either wear, monocularly, a “high magnitude” (H: +4.00DS/-8.00DC) crossed-cylindrical lens oriented at one of four axes (45, 90, 135, and 180; n = 20 in each group), or were left untreated (controls; n = 8). Two additional groups wore a “low magnitude” (L: +2.00DS/−4.00DC) cylindrical lens orientated at either axis 90 or 180 (n = 20 and n = 18, respectively). Refractions were measured at P5 and after 7 days of treatment for all chicks (P12), whereas videokeratography and ex-vivo eyeshape analysis were performed at P12 for a subset of chicks in each group (n = 8). Results Compared to controls, chicks in the treatment groups developed significant amounts of refractive astigmatism (controls: 0.03±0.22DC; treatment groups: 1.34±0.22DC to 5.51±0.26DC, one-way ANOVAs, p≤0.05) with axes compensatory to those imposed by the cylindrical lenses. H cylindrical lenses induced more refractive astigmatism than L lenses (H90 vs. L90: 5.51±0.26D vs. 4.10±0.16D; H180 vs. L180: 2.84±0.44D vs. 1.34±0.22D, unpaired two-sample t-tests, both p≤0.01); and imposing with-the-rule (H90 and L90) and against-the-rule astigmatisms (H180 and L180) resulted in, respectively, steeper and flatter corneal shape. Both corneal and internal astigmatisms were moderately to strongly correlated with refractive astigmatisms (Pearson’s r: +0.61 to +0.94, all p≤0.001). In addition, the characteristics of astigmatism were significantly correlated with multiple eyeshape parameters at the posterior segments (Pearson’s r: -0.27 to +0.45, all p≤0.05). Conclusions Chicks showed compensatory ocular changes in response to the astigmatic magnitudes imposed in this study. The correlations of changes in refractive, corneal, and posterior eyeshape indicate the involvement of anterior and posterior ocular segments during the

  4. Comparison of corneal power, astigmatism, and wavefront aberration measurements obtained by a point-source color light-emitting diode-based topographer, a Placido-disk topographer, and a combined Placido and dual Scheimpflug device.

    PubMed

    Ventura, Bruna V; Wang, Li; Ali, Shazia F; Koch, Douglas D; Weikert, Mitchell P

    2015-08-01

    To evaluate and compare the performance of a point-source color light-emitting diode (LED)-based topographer (color-LED) in measuring anterior corneal power and aberrations with that of a Placido-disk topographer and a combined Placido and dual Scheimpflug device. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas USA. Retrospective observational case series. Normal eyes and post-refractive-surgery eyes were consecutively measured using color-LED, Placido, and dual-Scheimpflug devices. The main outcome measures were anterior corneal power, astigmatism, and higher-order aberrations (HOAs) (6.0 mm pupil), which were compared using the t test. There were no statistically significant differences in corneal power measurements in normal and post-refractive surgery eyes and in astigmatism magnitude in post-refractive surgery eyes between the color-LED device and Placido or dual Scheimpflug devices (all P > .05). In normal eyes, there were no statistically significant differences in 3rd-order coma and 4th-order spherical aberration between the color-LED and Placido devices and in HOA root mean square, 3rd-order coma, 3rd-order trefoil, 4th-order spherical aberration, and 4th-order secondary astigmatism between the color-LED and dual Scheimpflug devices (all P > .05). In post-refractive surgery eyes, the color-LED device agreed with the Placido and dual-Scheimpflug devices regarding 3rd-order coma and 4th-order spherical aberration (all P > .05). In normal and post-refractive surgery eyes, all 3 devices were comparable with respect to corneal power. The agreement in corneal aberrations varied. Drs. Wang, Koch, and Weikert are consultants to Ziemer Ophthalmic Systems AG. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Surgical, Inc., and i-Optics Corp. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Effect of Orbital Decompression on Corneal Topography in Patients with Thyroid Ophthalmopathy

    PubMed Central

    Kim, Su Ah; Jung, Su Kyung; Paik, Ji Sun; Yang, Suk-Woo

    2015-01-01

    Objective To evaluate changes in corneal astigmatism in patients undergoing orbital decompression surgery. Methods This retrospective, non randomized comparative study involved 42 eyes from 21 patients with thyroid ophthalmopathy who underwent orbital decompression surgery between September 2011 and September 2014. The 42 eyes were divided into three groups: control (9 eyes), two-wall decompression (25 eyes), and three-wall decompression (8 eyes). The control group was defined as the contralateral eyes of nine patients who underwent orbital decompression surgery in only one eye. Corneal topography (Orbscan II), Hertel exophthalmometry, and intraocular pressure were measured at 1 month before and 3 months after surgery. Corneal topographic parameters analyzed were total astigmatism (TA), steepest axis (SA), central corneal thickness (CCT), and anterior chamber depth (ACD). Results Exophthalmometry values and intraocular pressure decreased significantly after the decompression surgery. The change (absolute value (|x|) of the difference) in astigmatism at the 3 mm zone was significantly different between the decompression group and the controls (p = 0.025). There was also a significant change in the steepest axis at the 3 mm zone between the decompression group and the controls (p = 0.033). An analysis of relevant changes in astigmatism showed that there was a dominant tendency for incyclotorsion of the steepest axis in eyes that underwent decompression surgery. Using Astig PLOT, the mean surgically induced astigmatism (SIA) was 0.21±0.88 D with an axis of 46±22°, suggesting that decompression surgery did change the corneal shape and induced incyclotorsion of the steepest axis. Conclusions There was a significant change in corneal astigmatism after orbital decompression surgery and this change was sufficient to affect the optical function of the cornea. Surgeons and patients should be aware of these changes. PMID:26352432

  6. Corneal curvature, pachymetry, and endothelial cell density in Marfan syndrome.

    PubMed

    Konradsen, Tiina R; Koivula, Annemari; Kugelberg, Maria; Zetterström, Charlotta

    2012-06-01

    To evaluate corneal curvature, pachymetry, and endothelial cell density (ECD) in Marfan syndrome (MFS). A case-control study in which K values, pachymetry, and ECD were compared in 39 MFS eyes and 40 control eyes matched for age and refraction was conducted. MFS eyes with lens subluxation also were compared with eyes without subluxation. The mean K(med) value in MFS eyes was lower than in the control eyes, 42.2 ± 1.9 versus 43.4 ± 1.4 dioptres (D), respectively (p = 0.02). Fifteen MFS eyes (38%) and three control eyes (8%) had K(med) values below 41.5 D (p = 0.0012). MFS eyes had generally more corneal astigmatism than control eyes, 1.1 ± 0.9 versus 0.8 ± 0.4 D (p = 0.035), and MFS eyes with lens subluxation had more corneal astigmatism than those without, 1.6 ± 1.1 versus 0.6 ± 0.3 D (p = 0.0002). Nine MFS eyes with corneal astigmatism exceeding 1.5 D also had a subluxated lens. No eyes had keratoconus. The mean pachymetry value was lower in MFS eyes compared to the controls, 485 ± 54.5 versus 514 ± 37.3 μm (p = 0.007); 24 MFS eyes (62%) and 10 control eyes (25%) had measurements below 500 μm (p = 0.01). The mean ECD values were similar in MFS and control eyes, 2815 ± 430 versus 2858 ± 458 cells/mm(2) (p = 0.66). The mean K value, pachymetry, and ECD values did not differ between MFS eyes with and without lens subluxation. Decreased K values and pachymetry could indicate MFS regardless of subluxation. High corneal astigmatism is associated with subluxation in MFS. Subluxation should be identified in MFS eyes with high corneal astigmatism. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  7. Excimer laser correction of hyperopia, hyperopic and mixed astigmatism: past, present, and future.

    PubMed

    Lukenda, Adrian; Martinović, Zeljka Karaman; Kalauz, Miro

    2012-06-01

    The broad acceptance of "spot scanning" or "flying spot" excimer lasers in the last decade has enabled the domination of corneal ablative laser surgery over other refractive surgical procedures for the correction of hyperopia, hyperopic and mixed astigmatism. This review outlines the most important reasons why the ablative laser correction of hyperopia, hyperopic and mixed astigmatism for many years lagged behind that of myopia. Most of today's scanning laser systems, used in the LASIK and PRK procedures, can safely and effectively perform low, moderate and high hyperopic and hyperopic astigmatic corrections. The introduction of these laser platforms has also significantly improved the long term refractive stability of hyperopic treatments. In the future, further improvements in femtosecond and nanosecond technology, eye-tracker systems, and the development of new customized algorithms, such as the ray-tracing method, could additionally increase the upper limit for the safe and predictable corneal ablative laser correction ofhyperopia, hyperopic and mixed astigmatism.

  8. Longitudinal Outcomes of U.S. Air Force Pilot Applicants With Waivered Astigmatism.

    PubMed

    Andrus, David E; Haynes, Jared T; Wright, Steven T

    2017-03-01

    Current U.S. Air Force medical standards allow applicants to enter pilot training with up to 1.50 D of astigmatism. However, waivers are considered for individuals with up to 3.00 D of astigmatism. Although typically a benign finding, higher levels of astigmatism may be progressive and can be associated with corneal ectasia (e.g., keratoconus or pellucid marginal degeneration) leading to reduced visual acuity with spectacles and/or soft contact lenses. The goal of this study was to evaluate the long-term outcomes of pilot applicants waivered into training with astigmatism exceeding the aeromedical standard. Subjects were identified on the basis of their enrollment in the Excessive Astigmatism Management Group maintained by the Aeromedical Consultation Service, Ophthalmology branch at Wright-Patterson Air Force Base, Ohio. Metrics evaluated included refractive status, visual acuity, aeromedical waiver status, safety data, and the development of corneal ectasia. Seventy-six subjects were tracked for up to 10 years, with an average follow-up period of 5.5 years. Mean astigmatism at initial examination was 1.91 D, although mean astigmatism on the basis of the most recent examination was 2.19 D. Subjects with excessive astigmatism who were waivered into pilot training showed an average increase in astigmatism of slightly less than 0.05 D annually, which equates to a total increase in astigmatism of approximately 0.25 D for the duration of the study. No subjects developed ectasia or were disqualified from flying for vision or refractive reasons. No mishaps were identified with vision being a causative or contributing factor. This study supports continuation of current Air Force waiver policy, although a longer follow-up period is required to consider modifying the aeromedical standard for astigmatism. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  9. Ocular residual astigmatism (ORA) in pre-cataract eyes prior to and after refractive lens exchange.

    PubMed

    Katz, Toam; Steinberg, Johannes; Druchkiv, Vasyl; Linke, Stephan J; Frings, Andreas

    2017-08-01

    The purpose of this study was to analyze ocular residual astigmatism (ORA) before and after implantation of two different optical types of non-toric multifocal intraocular lenses (MIOL) in pre-cataract patients. This retrospective cohort study analyzed 72 eyes from 72 consecutive patients after MIOL surgery . To investigate magnitude and axis of astigmatic changes, the concepts of true corneal astigmatism and Alpins vector method were applied. There were no statistically significant between-group differences prior to surgery. The mean refractive surgically induced astigmatism (RSIA) (P = 0.063) and the topographic SIA (TSIA) (P = 0.828) did not differ significantly between the lenses, and the summated vector mean for ORA was reduced in terms of magnitude by approximately 0.30 Diopter. ORA in pseudophakic eyes mainly results from the posterior corneal surface and less from IOL tilting, postoperative posterior capsule shrinkage, or secondary cataract.

  10. Asymmetric Corneal Flattening Effect After Small Incision Cataract Surgery.

    PubMed

    Alpins, Noel; Ong, James K Y; Stamatelatos, George

    2016-08-01

    To determine whether the flattening effect of corneal incisions differs between the right and left eye. A retrospective study of preoperative and postoperative corneal astigmatism was performed for patients who had bilateral cataract surgery by a right-handed surgeon. The change in corneal astigmatism was attributed to the 2.2-mm phacoemulsification incision, and the incisional flattening effect was calculated. The incisions were grouped by position on the eye and whether they were performed on the preoperative steep corneal meridian. A total of 1,298 eyes of 649 patients were evaluated. The flattening effect of temporal 2.2-mm incisions performed on the preoperative corneal steep meridian was different for right eyes (0.53 diopters [D]) and left eyes (0.34 D) (P = .017). The flattening effect of superior 2.2-mm incisions performed on the preoperative corneal steep meridian was equivalent in the two eyes. The flattening effect of a corneal incision may depend on whether it has been performed on the right or the left eye. [J Refract Surg. 2016;32(9):598-603.]. Copyright 2016, SLACK Incorporated.

  11. Changes in Keratometric Values and Corneal High Order Aberrations After Hydrogel Inlay Implantation.

    PubMed

    Whang, Woong-Joo; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    We sought to analyze surgically induced refractive change (SIRC) and change in high-order aberration after Raindrop corneal inlay insertion (ReVision Optics, Lake Forest, CA), and assess the extent to which Raindrop corneal inlay insertion could correct presbyopia. Interventional case series. Seventeen patients were included if they had a corneal thickness ≥500 μm and a stable manifest spherical equivalent refraction between 0.50 and +1.00 diopters (D). The Raindrop corneal inlay was implanted on the stromal bed of a femtosecond laser-assisted generated flap of nondominant eyes. Manifest refraction, corneal powers, and corneal high-order aberrations were measured preoperatively and at 3 and 12 months postoperatively. The SIRC by manifest refraction was 0.99 ± 0.26 D. The changes derived from simulated keratometry (K), true net power, and equivalent K reading (EKR) at 1.0-4.0 mm were greater than the SIRC (all P < .01) while the change in EKR at 6.0 mm was less than the SIRC (P < .01). The changes in EKR 5.0 mm, automated K, and EKR 4.5 mm did not differ significantly from the SIRC (P = .81, .29, and .09, respectively), and the difference was the least for EKR 5.0 mm. In analysis of high-order aberrations, only spherical aberration showed statistically significant difference between preoperative and postoperative on both anterior cornea and total cornea (all P < .01). Raindrop corneal inlay corrects presbyopia via increasing negative spherical aberration. The equivalent K reading at 5.0 mm accurately reflected the SIRC, and would be applicable for intraocular power prediction before cataract surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Comparison of Keratometry Obtained by a Swept Source OCT-Based Biometer with a Standard Optical Biometer and Scheimpflug Imaging.

    PubMed

    Asena, Leyla; Akman, Ahmet; Güngör, Sirel Gür; Dursun Altınörs, Dilek

    2018-04-09

    To assess agreement of a swept source-optical coherence tomography (SS-OCT) based Biometer with a standard IOLMaster device and Scheimpflug Imaging (SI) to acquire keratometric measurements in cataract patients. In this prospective comparative study, 101 eyes of 101 cataract surgery candidates, aged 24-81 years, were sequentially examined using three devices. Keratometry values at the flat (K1) and steep (K2) axis, mean corneal power (Km) and magnitude of corneal astigmatism as well as J0 and J45 vectoral components of astigmatism obtained with the SS-OCT based biometer (IOLMaster 700) were compared with those obtained with the IOLMaster 500 and SI. The agreement between measurements was evaluated by the Bland-Altman method, intraclass correlation coefficients (ICCs) and repeated-measures analysis of variance. Mean K1 values from the three devices were similar (p = 0.09). Mean K2 and Km values of IOLMaster 700 were higher than SI and lower than IOLMaster 500 (p = 0.04 for K2 and p = 0.02 for Km). There was a strong correlation between K1, K2, Km and magnitude of astigmatism obtained with all devices (r ≥ 0.80 and p < 0.01). The 95% limits of agreement (LoA) width for each keratometric value were highest for the comparison between IOLMaster 500 and SI and lowest for the comparison between IOLMaster 700 and 500. The mean differences (width of 95% LoA) for J0 and J45 vectoral components were 0.005 (2.19) and 0.12 (2.92) for the measurements obtained by IOLMaster 700 vs IOLMaster 500 and 0.06 (1.79) and 0.02 (1.58) for the measurements obtained by IOLMaster 700 vs SI, respectively. With ICCs close to 1, the agreement between all devices was excellent for keratometric measurements. Mean K2, Km and astigmatism measurements from IOLMaster 700 were lower than IOLMaster 500 and higher than SI. However, the differences were quite small and are not expected to affect the final IOL power.

  13. Laser-assisted corneal welding in cataract surgery: retrospective study.

    PubMed

    Menabuoni, Luca; Pini, Roberto; Rossi, Francesca; Lenzetti, Ivo; Yoo, Sonia H; Parel, Jean-Marie

    2007-09-01

    To evaluate the efficacy of laser welding to close corneal wounds in cataract surgery. Department of Ophthalmology, Hospital of Misericordia e Dolce, Prato, Italy. This retrospective nonrandomized interventional case series included 20 eyes of 20 patients. All eyes had cataract with visual acuity worse than 20/200. Ten patients had phacoemulsification surgery, and 10 had extracapsular cataract extraction (ECCE). Surgeries were followed by laser-assisted closure of the corneal wounds by diode laser welding of the stroma using a technique established in animal models. Preoperative and postoperative (1, 3, 7, 30, and 90 days) astigmatism, level of inflammation, Seidel testing, and endothelial cell counts were obtained. There were minor differences in preoperative and postoperative astigmatism except in 1 eye in the ECCE group. The Seidel test showed no wound leakage during the follow-up examinations, and endothelial cell loss was similar to that published for standard surgical cataract procedures. No collateral effects of the laser welding were detected, nor was postoperative inflammation. Astigmatism was slightly affected by the use of laser welding for corneal wound closure after phacoemulsification and ECCE. The laser-assisted corneal sealing procedure was rapid and safe and could serve as an alternative to corneal suturing, with significant potential applications for the closure of longer incisions, such as those used in penetrating keratoplasty.

  14. Inheritance of astigmatism: evidence for a major autosomal dominant locus.

    PubMed Central

    Clementi, M; Angi, M; Forabosco, P; Di Gianantonio, E; Tenconi, R

    1998-01-01

    Although astigmatism is a frequent refractive error, its mode of inheritance remains uncertain. Complex segregation analysis was performed, by the POINTER and COMDS programs, with data from a geographically well-defined sample of 125 nuclear families of individuals affected by astigmatism. POINTER could not distinguish between alternative genetic models, and only the hypothesis of no familial transmission could be rejected. After inclusion of the severity parameter, COMDS results defined a genetic model for corneal astigmatism and provided evidence for single-major-locus inheritance. These results suggest that genetic linkage studies could be implemented and that they should be limited to multiplex families with severely affected individuals. PMID:9718344

  15. Measuring mental workload: ocular astigmatism aberration as a novel objective index.

    PubMed

    Jiménez, Raimundo; Cárdenas, David; González-Anera, Rosario; Jiménez, José R; Vera, Jesús

    2018-04-01

    This study assessed the effect of two perceptually matched mental tasks with different levels of mental demand on ocular aberrations in a group of young adults. We measured ocular aberration with a wavefront sensor, and total, internal and corneal RMS (root mean square) aberrations were calculated from Zernike coefficients, considering natural and scaled pupils (5, 4.5, and 4 mm). We found that total, internal and corneal astigmatism RMS showed significant differences between mental tasks with natural pupils (p < .05), and this effect was maintained with 5 mm scaled pupils (total RMS astigmatism, p < .05). Consistently, pupil size, intraocular pressure, perceived mental load and cognitive performance were influenced by the level of mental complexity (p < .05 for all). The findings suggest that ocular astigmatism aberration, mediated by intraocular pressure, could be an objective, valid reliable index to evaluate the impact of cognitive processing in conjunction with others physiological markers in real world contexts. Practitioner Summary: The search continues for a valid, reliable, convenient method of measuring mental workload. In this study we found ocular astigmatism aberration is sensitive to the cumulative effect of mental effort. It shows promise of being a novel ocular index which may help to assess mental workload in real situations.

  16. Analysis of corneal topography in patients with pure microphthalmia in Eastern China.

    PubMed

    Hu, Pei-Hong; Gao, Gui-Ping; Yu, Yao; Pei, Chong-Gang; Zhou, Qiong; Huang, Xin; Zhang, Ying; Shao, Yi

    2015-12-01

    To determine the typical corneal changes in pure microphthalmia using a corneal topography system and identify characteristics that may assist in early diagnosis. Patients with pure microphthalmia and healthy control subjects underwent corneal topography analysis (Orbscan IIZ® Corneal Topography System; Bausch and Lomb, Bridgewater, NJ, USA) to determine degree of corneal astigmatism (mean A), simulation of corneal astigmatism (sim A), mean keratometry (mean K), simulated keratometry (sim K), irregularities in the 3 - and 5-mm zone, and mean thickness of nine distinct corneal regions. Patients with pure microphthalmia (n = 12) had significantly higher mean K, sim K, mean A, sim A, 3.0 mm irregularity and 5.0 mm irregularity, and exhibited significantly more false keratoconus than controls (n = 12). There was a significant between-group difference in the morphology of the anterior corneal surface and the central curvature of the cornea. Changes in corneal morphology observed in this study could be useful in borderline situations to confirm the diagnosis of pure microphthalmia. © The Author(s) 2015.

  17. Spherical aberrations of human astigmatic corneas.

    PubMed

    Zhao, Huawei; Dai, Guang-Ming; Chen, Li; Weeber, Henk A; Piers, Patricia A

    2011-11-01

    To evaluate whether the average spherical aberration of human astigmatic corneas is statistically equivalent to human nonastigmatic corneas. Spherical aberrations of 445 astigmatic corneas prior to laser vision correction were retrospectively investigated to determine Zernike coefficients for central corneal areas 6 mm in diameter using CTView (Sarver and Associates). Data were divided into groups according to cylinder power (0.01 to 0.25 diopters [D], 0.26 to 0.75 D, 0.76 to 1.06 D, 1.07 to 1.53 D, 1.54 to 2.00 D, and >2.00 D) and according to age by decade. Spherical aberrations were correlated with age and astigmatic power among groups and the entire population. Statistical analyses were conducted, and P<.05 was considered statistically significant. Mean patient age was 42.6±11 years. Astigmatic corneas had an average astigmatic power of 0.78±0.58 D and mean spherical aberration was 0.25±0.13 μm for the entire population and approximately the same (0.27 μm) for individual groups, ranging from 0.23 to 0.29 μm (P>.05 for all tested groups). Mean spherical aberration of astigmatic corneas was not correlated significantly with cylinder power or age (P>.05). Spherical aberrations are similar to those of nonastigmatic corneas, permitting the use of these additional data in the design of aspheric toric intra-ocular lenses. Copyright 2011, SLACK Incorporated.

  18. Refractive Lenticule Transplantation for Correction of Iatrogenic Hyperopia and High Astigmatism After LASIK.

    PubMed

    Lazaridis, Apostolos; Reinstein, Dan Z; Archer, Timothy J; Schulze, Stephan; Sekundo, Walter

    2016-11-01

    To design a technique for intrastromal transplantation of stromal lenticules with specific refractive power for correction of post-LASIK induced hyperopia and astigmatism. A 28-year-old patient was referred for consultation after complicated LASIK for moderate myopia and astigmatism. The refractive error of the right eye was severely overcorrected due to data entry error. Post-LASIK refraction showed high astigmatism (right eye: +6.50 -9.00 @ 84°) and corrected distance visual acuity (CDVA) of 20/32. The corneal thickness was 282 µm. A refractive lenticule transplantation was performed due to contact lens intolerance, poor visual acuity, and severe anisometropia. A toric and myopic lenticule, obtained from a donor using the femtosecond lenticule extraction technique, was implanted under the flap to reduce the refractive error, bring the refraction of the eye to the level correctable by phakic intraocular lens, and restore corneal volume. Six weeks postoperatively, the donor lenticule was spread smoothly in the interface with a minor temporal decentration in relation to pupil center. The refraction showed a reduction of astigmatism but a stronger myopization compared to preoperative calculations (right eye: -6.50 -4.00 @ 70°). At 3 months, the CDVA returned to the preoperative value of 20/32. One year postoperatively, corneal tomography showed no signs of ectasia and biomicroscopy revealed no signs of rejection. After implanting a toric myopic implantable collamer lens, the patient regained uncorrected distance visual acuity of 20/40 and full stereopsis. The refractive lenticule transplantation technique offers a solution for rare cases of post-LASIK hyperopia and high astigmatism while restoring the volume of thin corneas. Moreover, it is a reversible procedure with low probability of rejection. [J Refract Surg. 2016;32(11):780-786.]. Copyright 2016, SLACK Incorporated.

  19. The location of incision in cataract surgery and its impact on induced astigmatism.

    PubMed

    Hashemi, Hassan; Khabazkhoob, Mehdi; Soroush, Sara; Shariati, Reyhane; Miraftab, Mohammad; Yekta, Abbasali

    2016-01-01

    The purpose of the present study is a systematic review of previous studies on choosing the best incision site for the correction of astigmatism in cataract surgery and assessing the amount of surgically induced astigmatism (SIA) with each approach. Regardless of astigmatism axis, studies show that using an on-axis incision is associated with favorable results for 0.5-1.0 diopter (D) of astigmatism. In cases with more than 1.0 D astigmatism, paired on-axis incisions can be appreciably efficient in astigmatism correction and cause at least 1.5 D SIA. Considering the amount of SIA, a temporal incision is the best approach when the patient has minimal amounts of corneal astigmatism preoperatively. At higher levels of astigmatism, if no other astigmatism correction method is used simultaneously, the temporal incision is used less frequently; however, since it is associated with the least SIA, it is still the choice site when another correction method is used. The temporal incisions in cataract surgery are associated with little SIA and are appropriate choices for mild preoperative astigmatism. At higher levels of preoperative astigmatism, superior incisions are associated with better results when combined methods are not applied.

  20. Refractive astigmatism and the toricity of ocular components in human infants.

    PubMed

    Mutti, Donald O; Mitchell, G Lynn; Jones, Lisa A; Friedman, Nina E; Frane, Sara L; Lin, Wendy K; Moeschberger, Melvin L; Zadnik, Karla

    2004-10-01

    Many studies have characterized astigmatism in infancy, but few have been longitudinal or contained ocular component data. This study characterized the frequency, orientation, and longitudinal change with age of infant astigmatism. Additional factors investigated were the influence of early astigmatism on emmetropization and its relation to corneal and lenticular toricity. Three hundred two infants were enrolled in the study. Of these, 298 provided data for at least one visit at 3 +/- 1 months, 9 +/- 1 months, 18 +/- 2 months, and 36 +/- 3 months. Testing included cycloplegic retinoscopy (cyclopentolate 1%), video-based keratophakometry, and ultrasonography over the closed eyelid. Astigmatism > or =1.00 DC was common at 3 months of age (41.6%) but decreased in prevalence to 4.1% by 36 months (p < 0.0001). The most common orientation was with-the-rule at 3 months (37.0% compared with 2.7% for against-the-rule) but against-the-rule at 36 months (3.2% compared with 0.9% for with-the-rule). Most of the change in the average value of the horizontal/vertical component of astigmatism (J0) occurred between 3 and 9 months (-0.26 +/- 0.36 D; p < 0.0001) with no significant change between 9 and 36 months (-0.05 +/- 0.36 D; p=0.09). Spherical equivalent refractive error was not correlated with J0 at 3 and 9 months (R=0.002, p=0.48 and R=0.001, p=0.56, respectively). The two were only weakly correlated at 18 and 36 months (R=0.06 for each age, p <0.0001, p=0.0002, respectively). Changes in spherical equivalent between 3 and 9 months were unrelated to either the initial value of J0 (partial R for J0=0.0001; p=0.85) or the change in J0 (partial R for change in J0=0.0031; p=0.31). Across all the ages, corneal toricity was with-the-rule, and lenticular toricity was against-the-rule (produced by the toricity of the posterior lens surface). The cornea and anterior lens surface became more spherical with age, contributing to the shift away from with-the-rule refractive astigmatism

  1. Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism

    PubMed Central

    Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S

    2013-01-01

    Aims In a previous study, we proposed that corneal topography performed 30–40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. Methods 10/0 nylon interrupted sutures were placed, to secure the graft–host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30–40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4–6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Results Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). Conclusion SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty. PMID:23743526

  2. Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism.

    PubMed

    Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S

    2013-09-01

    In a previous study, we proposed that corneal topography performed 30-40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. 10/0 nylon interrupted sutures were placed, to secure the graft-host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30-40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4-6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty.

  3. Corneal epithelium, visual acuity, and laser refractive keratectomy

    NASA Astrophysics Data System (ADS)

    Simon, Gabriel; Parel, Jean-Marie A.; Kervick, Gerard N.; Rol, Pascal O.; Hanna, Khalil; Thompson, Keith P.

    1991-06-01

    Photorefractive keratectomy (PRK) using an argon fluoride excimer laser for photoablation of the cornea shows potential for the precise correction of refractive errors in patients. Usually, the epithelium is mechanically removed, and Bowman's layer and stromal tissue are photoablated to precomputed depths and shapes that are based on known ablation rates for these tissues. After four day's time, the epithelium has regrown. Assuming the epithelium to be preoperatively uniform in thickness across the central optical zone, and assuming that it regrows to the same thickness, a theoretical precision of +/- 0.05 diopters is achievable with PRK. Keratometric measurements of the epithelium and of Bowman's layer were made at the 2.0 and 3.6 mm optical zones on 10 fresh cadaver eyes (<21 hours postmortem). In the eyes studied, the epithelium thickness was found to vary across the central optical zone, accounting for the measured refractive differences of 0.5 to 1.8 diopters. Bowman's layer was found to be more prolated than the epithelial surface (ratios: 1.005 compared to 1.033). In addition, the surface of Bowman's layer had a larger degree of astigmatism. Other studies have shown that the epithelium regrowth is a function of the newly exposed corneal topography as the wing cells compensate for irregularities in Bowman's surface. As the preoperative topography of the epithelium cannot be used as a reference surface when computing photoablation depth, intraoperative keratometry of Bowman's surface becomes a necessity in PRK.

  4. Clinical outcomes of laser in situ keratomileusis with an aberration-neutral profile centered on the corneal vertex comparing vector planning with manifest refraction planning for the treatment of myopic astigmatism.

    PubMed

    Arbelaez, Maria Clara; Alpins, Noel; Verma, Shwetabh; Stamatelatos, George; Arbelaez, Juan Guillermo; Arba-Mosquera, Samuel

    2017-12-01

    To evaluate clinical outcomes of laser in situ keratomileusis (LASIK) with an aberration-neutral profile centered on the estimated visual axis (considering 70% of the pupil offset toward the corneal vertex) comparing vector planning with manifest refraction planning for the treatment of myopic astigmatism. Muscat Eye Laser Center, Muscat, Sultanate of Oman, Muscat, Oman. Retrospective case series. The outcomes were evaluated at a 6-month follow-up in eyes showing ocular residual astigmatism (ORA) over 0.75 diopters (D) preoperatively. Eighty-five treatments were based on manifest astigmatism (preoperative sphere -2.11 D ± 1.3 [SD], cylinder -0.90 ± 1.0 D), and 79 treatments were based on vector planning (preoperative sphere -2.46 ± 1.5 D, cylinder -0.78 ± 0.79 D). At a 6-month follow-up, 128 patients (164 eyes) were evaluated and no significant differences were observed between the 2 groups in terms of difference between corrected distance visual acuity and uncorrected distance visual acuity (UDVA) (P = .1, t test and Fisher exact test Snellen lines 1 or better, P = .4) and postoperative UDVA (P = .05, t test and Fisher exact test for UDVA 20/16 or better, P = .3). Significant differences were observed between the 2 groups in terms of achieved spherical equivalent (P = .04), corneal toricity, and ORA (P < .001, t test and Fisher exact test for ORA ≤0.75 D, P < .001). Performing LASIK for myopic astigmatism with the vector planning approach resulted in comparable visual outcomes to manifest refraction planning. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Corneal shape and astigmatism: with a note on myopia.

    PubMed Central

    Weale, R A

    1988-01-01

    The elliptical shape and the physiological astigmatism of the normal neonatal human cornea are attributed to the ellipsoidal shape of the eyeball. This in turn is a feature of ocular development. The analysis is used to examine earlier observations on myopia. PMID:3179259

  6. Non-Orthogonal Corneal Astigmatism among Normal and Keratoconic Brazilian and Chinese populations.

    PubMed

    Abass, Ahmed; Clamp, John; Bao, FangJun; Ambrósio, Renato; Elsheikh, Ahmed

    2018-06-01

    To investigate the prevalence of non-orthogonal astigmatism among normal and keratoconic Brazilian and Chinese populations. Topography data were obtained using the Pentacam High Resolution (HR) system ® from 458 Brazilian (aged 35.6 ± 15.8 years) and 505 Chinese (aged 31.6 ± 10.8 years) eyes with no history of keratoconus or refractive surgery, and 314 Brazilian (aged 24.2 ± 5.7 years) and 74 Chinese (aged 22.0 ± 5.5 years) keratoconic eyes. Orthogonal values of optical flat and steep powers were determined by finding the angular positions of two perpendicular meridians that gave the maximum difference in power. Additionally, the angular positions of the meridians with the minimum and maximum optical powers were located while being unrestricted by the usual orthogonality assumption. Eyes were determined to have non-orthogonal astigmatism if the angle between the two meridians with maximum and minimum optical power deviated by more than 5° from 90°. Evidence of non-orthogonal astigmatism was found in 39% of the Brazilian keratoconic eyes, 26% of the Chinese keratoconic eyes, 29% of the Brazilian normal eyes and 20% of the Chinese normal eyes. The large percentage of participants with non-orthogonal astigmatism in both normal and keratoconic eyes illustrates the need for the common orthogonality assumption to be reviewed when correcting for astigmatism. The prevalence of non-orthogonality should be considered by expanding the prescription system to consider the two power meridians and their independent positions.

  7. Small incision lenticule extraction (SMILE) in the correction of myopic astigmatism: outcomes and limitations - an update.

    PubMed

    Alió Del Barrio, Jorge L; Vargas, Verónica; Al-Shymali, Olena; Alió, Jorge L

    2017-01-01

    Small Incision Lenticule Extraction (SMILE) is a flap-free intrastromal technique for the correction of myopia and myopic astigmatism. To date, this technique lacks automated centration and cyclotorsion control, so several concerns have been raised regarding its capability to correct moderate or high levels of astigmatism. The objective of this paper is to review the reported SMILE outcomes for the correction of myopic astigmatism associated with a cylinder over 0.75 D, and its comparison with the outcomes reported with the excimer laser-based corneal refractive surgery techniques. A total of five studies clearly reporting SMILE astigmatic outcomes were identified. SMILE shows acceptable outcomes for the correction of myopic astigmatism, although a general agreement exists about the superiority of the excimer laser-based techniques for low to moderate levels of astigmatism. Manual correction of the static cyclotorsion should be adopted for any SMILE astigmatic correction over 0.75 D.

  8. Developmental compensation of imposed astigmatism is not initiated by astigmatic accommodation in chickens.

    PubMed

    Thomas, S; Schaeffel, F

    2000-01-01

    ) 78 +/- 24 vs. 131 +/- 35 deg). The most intuitive mechanism for compensation of astigmatic refractive errors, astigmatic accommodation, could not be demonstrated in chickens. In light of this finding, it seems unlikely that a visually controlled mechanism is operating during development to reduced astigmatism by changing corneal or lenticular growth.

  9. Microincision Hydrophobic Acrylic Aspheric Toric Intraocular Lens for Astigmatism and Cataract Correction.

    PubMed

    Bissen-Miyajima, Hiroko; Negishi, Kazuno; Hieda, Osamu; Kinoshita, Shigeru

    2015-06-01

    To evaluate the efficacy and safety of a new acrylic one-piece toric intraocular lens (IOL). This prospective multicenter clinical trial included 93 eyes of 61 patients that were implanted with a hydrophobic acrylic toric IOL from 2010 to 2012 and followed for 1 year. This IOL uses the platform of a microincision one-piece aspheric IOL, the NY-60 IOL (HOYA, Tokyo, Japan), with three increments in cylindrical power (NHT15, 1.5 diopters [D]; NHT23, 2.25 D; and NHT30, 3.0 D). The inclusion criterion was preoperative corneal astigmatism from 0.75 to 3.00 D. The primary endpoint was uncorrected distance visual acuity (UDVA) of 0.0 logMAR (20/20 Snellen) or better 6 months postoperatively. In addition to UDVA, corrected distance visual acuity (CDVA), residual astigmatism, stability of the IOL alignment, need of realignment, and the rate of Nd:YAG laser capsulotomy were evaluated up to 1 year postoperatively. Errors in astigmatic correction were assessed using Alpin's vector analysis. The primary endpoint was achieved in 54.8% of eyes. One year postoperatively, the logMAR UDVAs were 0.02 ± 0.13, 0.05 ± 0.17, and 0.09 ± 0.14 with models NHT15, NHT23, and NHT30, which corresponds to 0.96 (19/20 Snellen), 0.89 (18/20 Snellen), and 0.82 (16/20 Snellen), respectively. One year postoperatively, the residual astigmatism was 0.66 ± 0.58 D. In each evaluation, the mean absolute change in the position of the axis mark was between 1.93° and 2.32°. Three eyes required repositioning of the IOL axis and 2 eyes received Nd:YAG laser capsulotomy. The correction error showed an undercorrection with against-the-rule astigmatism and overcorrection with with-the-rule astigmatism. The new one-piece toric IOL provided desirable clinical outcomes and stability in eyes with corneal astigmatism. Copyright 2015, SLACK Incorporated.

  10. Laser in situ keratomileusis for -6.00 to -18.00 diopters of myopia and up to -5.00 diopters of astigmatism: 15-year follow-up.

    PubMed

    Alió, Jorge L; Soria, Felipe; Abbouda, Alessandro; Peña-García, Pablo

    2015-01-01

    To evaluate the long-term outcomes of laser in situ keratomileusis (LASIK) for high myopia with or without astigmatism. Vissum Instituto Oftalmologico de Alicante and Miguel Hernandez University, Alicante, Spain. Retrospective-prospective case series. Laser in situ keratomileusis was performed using the Visx 20/20 excimer laser. The minimum follow-up was 15 years. The main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and corneal topography. This study included 40 patients (40 eyes) with a mean age of 51.08 years ± 6.67 (SD) (range 41 to 60 years) with high myopia (-6.00 to -18.00 diopters [D]). At 15 years, the safety index was 1.23 and the efficacy index, 0.95. During the follow-up, a significant increase in the dioptric power of all keratometric variables was detected (P≤.028, Friedman test), the most notable increase occurring between 3 months and 1 year (P≤.005). At 15 years, 46.15% of the eyes were within ±1.00 D of the attempted spherical equivalent and 64.10% were within ±2.00 D. The UDVA at 15 years was 20/25 or better in 43.59% of eyes and 20/40 or better in 64.10% of eyes. The postoperative CDVA was significantly better than preoperatively (P<.001). The postoperative complications were minor except in 1 eye in which ectasia occurred. Laser in situ keratomileusis for high myopia was safe over the long term. However, significant myopic regression with time was detected. Low preoperative pachymetry and low residual stromal bed were predictors of keratometric regression. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. [Evaluation of Postoperative Astigmatism Correction and Postoperative Rotational Stability of Two Toric Intraocular Lenses].

    PubMed

    Grohlich, M; Miháltz, K; Lasta, M; Weingessel, B; Vécsei-Marlovits, V

    2017-06-01

    Background The aim of this retrospective study was to evaluate the rotational stability and the refractive outcome of two different toric IOLs. Methods This study included 41 eyes with corneal astigmatism greater than 1.5 diopters (D). All patients underwent surgery in the Department of Ophthalmology at Hietzing Hospital between 2010 and 2013. The study lenses were the Alcon AcrySof IQ Toric IOL and the Abbott Tecnis Toric Aspheric IOL. Measurements of corneal topography and aberrations were performed with the HOYA iTrace™. Determination of visual acuity was performed with ETDRS charts. Optical aberrations were represented by Zernike coefficients, and optical quality was assessed with the Strehl ratio. Results Mean rotation was 4.92° (standard deviation: ± 4.10°) in the Alcon group and 4.31° (± 4.59°) in the Abbott group. No significant difference was observed between the two toric intraocular lenses. Rotational stability was comparable to results from other studies. Astigmatism correction was visualised with a power-vector analysis, which demonstrated similar results in both lenses and a clear success of astigmatism correction. No statistically significant differences were found in residual refractive astigmatism, which was 0.85 ± 0.48 D in the Alcon group and 1.09 ± 0.66 in the Tecnis group. No significant difference between the two groups was found in the Strehl ratio. Conclusion Implantation of toric intraocular lenses (Alcon + Abbott) in patients with regular astigmatism is an effective and safe method, which should be offered to patients. Both the Tecnis and the AcrySof toric IOLs similarly reduced ocular astigmatism. Georg Thieme Verlag KG Stuttgart · New York.

  12. Corneal perforation after conductive keratoplasty with previous refractive surgery.

    PubMed

    Kymionis, George D; Titze, Patrik; Markomanolakis, Marinos M; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-12-01

    A 56-year-old woman had conductive keratoplasty (CK) for residual hyperopia and astigmatism. Three years before the procedure, the patient had arcuate keratotomy, followed by laser in situ keratomileusis 2 years later for high astigmatism correction in both eyes. During CK, a corneal perforation occurred in the right eye; during the postoperative examination, an iris perforation and anterior subcapsule opacification were seen beneath the perforation site. The perforation was managed with a bandage contact lens and an antibiotic-steroid ointment; it had a negative Seidel sign by the third day. The surgery in the left eye was uneventful. Three months after the procedure, the uncorrected visual acuity was 20/32 and the best corrected visual acuity 20/20 in both eyes with a significant improvement in corneal topography. Care must be taken to prevent CK-treated spots from coinciding with areas in the corneal stroma that might have been altered by previous refractive procedures.

  13. Comparison of the predictability of refractive cylinder correction by laser in situ keratomileusis in eyes with low or high ocular residual astigmatism.

    PubMed

    Archer, Timothy J; Reinstein, Dan Z; Piñero, David P; Gobbe, Marine; Carp, Glenn I

    2015-07-01

    To compare the manifest refractive cylinder (MRC) predictability of myopic astigmatism laser in situ keratomileusis (LASIK) between eyes with low and high ocular residual astigmatism (ORA). London Vision Clinic, London, United Kingdom. Retrospective case study. The ORA was considered the vector difference between the MRC and the corneal astigmatism. The index of success (IoS), difference vector ÷ MRC, was analyzed for different groups as follows: stage 1, low ORA (ORA ÷ MRC <1), high ORA (ORA ÷ MRC ≥1); stage 2, low ORA group reduced to match the high ORA group for MRC; stage 3, grouped by ORA magnitude with low ORA (<0.50 diopters [D]), mid ORA (0.50 to 1.24 D), and high ORA (≥1.25 D); stage 4, high ORA group subdivided into low (<0.75 D) and high (≥0.75 D) corneal astigmatism. For stage 1, the mean preoperative MRC and mean IoS were -1.32 D ± 0.65 (SD) (range -0.55 to -3.77 D) and 0.27, respectively, for low ORA and -0.79 ± 0.20 D (range -0.56 to -2.05 D) and 0.37, respectively, for high ORA. For stage 2, the mean IoS increased to 0.32 for low ORA. For stage 3, the mean IoS was 0.28, 0.29, and 0.31 for low ORA, mid ORA, and high ORA, respectively. For stage 4, the mean IoS was 0.20 for high ORA/low corneal astigmatism and 0.35 for high ORA/high corneal astigmatism. The MRC predictability was slightly worse in eyes with high ORA when grouped by the ORA ÷ MRC. Matching for the MRC and grouping by ORA magnitude resulted in similar predictability; however, eyes with high ORA and high corneal astigmatism were less predictable. Dr. Reinstein is a consultant to Carl Zeiss Meditec AG, has a proprietary interest in the Artemis technology (Arcscan, Inc.), and is an author of patents related to very-high-frequency digital ultrasound administered by the Center for Technology Licensing at Cornell University, Ithaca, New York, USA. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS

  14. [Predictability of residual astigmatism after implantation of posterior chamber toric lenses].

    PubMed

    Mies, D; Klink, T; Eisenbarth, W; Meyer, L M

    2018-01-01

    The objective of the study was to examine the predictability of residual astigmatism after cataract surgery and implantation of the posterior chamber aspheric toric lens TECNIS® ZCT, Abott Medical Optic (Ettlingen, Deutschland). The retrospective study included a total of 88 patient eyes undergoing a cataract operation with a toric lens implantation between March 2014 and October 2015. The inclusion criteria were a regular astigmatism of at least 0.75 dpt. Posterior chamber toric lenses (model Tecnis ZCT) were exclusively implanted. Post-surgery check-ups were performed after 1 day, 1 month and 2 months. Main study outcome was best-corrected visual acuity (BCVA), spherical and astigmatic aberration and the difference between expected and actual residual astigmatism after cataract surgery. The median reduction of corneal astigmatism was from -2.50 dpt (±1.06 dpt) to -0.75 dpt (±0.51 dpt) (p ≤ 0.05). The median BCVA increased from 0.37 logMAR (±0.25 logMAR) before surgery to 0.09 logMAR (±0.10 logMAR) after surgery. The spherical equivalent was reduced from +3.50 dpt (±1.11 dpt) (presurgery) to -0.56 dpt (±0.51 dpt) (postsurgery) in hyperopic patients and from -2.44 dpt (±3.03 dpt) to -0.69 dpt (±0.81 dpt) in myopic patients. By using the power vector analysis no significant deviation from the expected target values was observed; however, the median discrepancy between the expected and actual residual astigmatism was -0.50 dpt despite a surgical orientation of the intraocular lens (IOL) within 5° of the desired axis. The IOL showed a median rotation of 3.00° (±4.46°). Implantation of the aspheric toric intraocular lens Tecnis ZCT is a predictable, effective and reproducible tool in cataract surgery to account for regular corneal astigmatis; however, despite an optimal surgical orientation of the toric IOL, a small and rarely a large discrepancy might occur between expected and actual residual astigmatism.

  15. A schematic eye model for the effects of translation and rotation of ocular components on peripheral astigmatism.

    PubMed

    Barnes, D A; Dunne, M C; Clement, R A

    1987-01-01

    The relative contributions of translation and rotation of the cornea and lens to peripheral astigmatic asymmetry have been investigated using a linear algebraic ray tracing method. It is believed that lenticular rotation is responsible for angle alpha, so bringing about peripheral astigmatic asymmetry, as normally occurs in human eyes over the temporal and nasal retina. Rotation of the cornea may be responsible for the small numbers of eyes which exhibit large amounts of peripheral astigmatic asymmetry. The effects of corneal rotation and translation on the dimensions of the entrance pupil are illustrated.

  16. Applications of corneal topography and tomography: a review.

    PubMed

    Fan, Rachel; Chan, Tommy Cy; Prakash, Gaurav; Jhanji, Vishal

    2018-03-01

    Corneal imaging is essential for diagnosing and management of a wide variety of ocular diseases. Corneal topography is used to characterize the shape of the cornea, specifically, the anterior surface of the cornea. Most corneal topographical systems are based on Placido disc that analyse rings that are reflected off the corneal surface. The posterior corneal surface cannot be characterized using Placido disc technology. Imaging of the posterior corneal surface is useful for diagnosis of corneal ectasia. Unlike corneal topographers, tomographers generate a three-dimensional recreation of the anterior segment and provide information about the corneal thickness. Scheimpflug imaging is one of the most commonly used techniques for corneal tomography. The cross-sectional images generated by a rotating Scheimpflug camera are used to locate the anterior and posterior corneal surfaces. The clinical uses of corneal topography include, diagnosis of corneal ectasia, assessment of corneal astigmatism, and refractive surgery planning. This review will discuss the applications of corneal topography and tomography in clinical practice. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  17. Femtosecond Lasers and Corneal Surgical Procedures.

    PubMed

    Marino, Gustavo K; Santhiago, Marcony R; Wilson, Steven E

    2017-01-01

    Our purpose is to present a broad review about the principles, early history, evolution, applications, and complications of femtosecond lasers used in refractive and nonrefractive corneal surgical procedures. Femtosecond laser technology added not only safety, precision, and reproducibility to established corneal surgical procedures such as laser in situ keratomileusis (LASIK) and astigmatic keratotomy, but it also introduced new promising concepts such as the intrastromal lenticule procedures with refractive lenticule extraction (ReLEx). Over time, the refinements in laser optics and the overall design of femtosecond laser platforms led to it becoming an essential tool for corneal surgeons. In conclusion, femtosecond laser is a heavily utilized tool in refractive and nonrefractive corneal surgical procedures, and further technological advances are likely to expand its applications. Copyright 2017 Asia-Pacific Academy of Ophthalmology.

  18. Off-axis astigmatism in the isolated chicken crystalline lens.

    PubMed

    Maier, Felix; Wahl, Siegfried; Schaeffel, Frank

    2016-12-01

    The chicken eye was previously found to have little off-axis astigmatism which is not explained by its special corneal shape but rather by the optical properties of the crystalline lens. To learn more about lens design, we studied off-axis astigmatism in the chicken lens in situ and compared it to a glass lens of similar power but with homogenous refractive index. After euthanasia, enucleated eye balls were cut in the equatorial plane right behind the scleral ossicles. The anterior segment was placed in a water-filled chamber. Several thin laser beams were projected in two perpendicular meridians through the lens under various eccentricities and the focal lengths were determined. Off-axis astigmatism across the horizontal visual field was determined as the differences in power in the two meridians. The same procedure was used for the glass lens. On-axis, the chicken crystalline lens had slightly more power in the vertical than in the horizontal meridian (-2.8±0.7D (SEM)). Astigmatism flipped sign and increased with eccentricity to reach +6.1±2.1D (SEM) at 33.5deg off-axis, as expected from off-axis astigmatism. Even though this value appears high, it was still 2.5 times lower than in the glass lens. A ZEMAX model of a lens with a homogeneous index and with surface profiles taken of the natural chicken lens revealed even higher levels of off-axis astigmatism. Obviously, the natural chicken lens displays much less off-axis astigmatism than a glass lens with similar power. Since its shape does not explain the low off-axis astigmatism, it must be due to a refined internal refractive index structure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Lower- and higher-order aberrations predicted by an optomechanical model of arcuate keratotomy for astigmatism.

    PubMed

    Navarro, Rafael; Palos, Fernando; Lanchares, Elena; Calvo, Begoña; Cristóbal, José A

    2009-01-01

    To develop a realistic model of the optomechanical behavior of the cornea after curved relaxing incisions to simulate the induced astigmatic change and predict the optical aberrations produced by the incisions. ICMA Consejo Superior de Investigaciones Científicas and Universidad de Zaragoza, Zaragoza, Spain. A 3-dimensional finite element model of the anterior hemisphere of the ocular surface was used. The corneal tissue was modeled as a quasi-incompressible, anisotropic hyperelastic constitutive behavior strongly dependent on the physiological collagen fibril distribution. Similar behaviors were assigned to the limbus and sclera. With this model, some corneal incisions were computer simulated after the Lindstrom nomogram. The resulting geometry of the biomechanical simulation was analyzed in the optical zone, and finite ray tracing was performed to compute refractive power and higher-order aberrations (HOAs). The finite-element simulation provided new geometry of the corneal surfaces, from which elevation topographies were obtained. The surgically induced astigmatism (SIA) of the simulated incisions according to the Lindstrom nomogram was computed by finite ray tracing. However, paraxial computations would yield slightly different results (undercorrection of astigmatism). In addition, arcuate incisions would induce significant amounts of HOAs. Finite-element models, together with finite ray-tracing computations, yielded realistic simulations of the biomechanical and optical changes induced by relaxing incisions. The model reproduced the SIA indicated by the Lindstrom nomogram for the simulated incisions and predicted a significant increase in optical aberrations induced by arcuate keratotomy.

  20. A Prospective Study of Pterygium Excision and Conjunctival Autograft With Human Fibrin Tissue Adhesive: Effects on Vision, Refraction, and Corneal Topography.

    PubMed

    Misra, Stuti; Craig, Jennifer P; McGhee, Charles N J; Patel, Dipika V

    2014-01-01

    This study aimed to investigate changes in visual acuity, corneal parameters, and topographic parameters after pterygium surgery. A prospective observational study was conducted. Twenty eyes of 20 participants undergoing pterygium excision with conjunctival autograft secured using human fibrin tissue adhesive were included in the study. All the participants were assessed preoperatively and 1 and 3 months postoperatively. The parameters included subjective refraction, visual acuity, and pterygium size (pterygium horizontal corneal length [PHCL]) and corneal tomography by Pentacam rotating Scheimpflug tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany). The astigmatic changes were calculated using vector analysis. The mean age of participants was 49.3 ± 12.1 years. Mean PHCL was 2.68 ± 0.30 mm. The mean best corrected visual acuity preoperatively was 6/7.5, improving significantly to 6/6 at 1 month (P = 0.001) with this improvement remaining stable at 3 months postoperatively (P = 0.34). There was no significant change in subjective astigmatism, however, mean topographic astigmatism decreased significantly at 1 month (4.36 diopter, P < 0.01) and remained unchanged at 3 months (P < 0.01). Greater PHCL was associated with greater changes in corneal astigmatism. Significant improvements and early stabilization of visual acuity and topographic astigmatism confirm the optical benefits of pterygium excision. These data also suggest a significant advantage of performing pterygium before rather than simultaneously with or after cataract surgery by enabling the most accurate biometry.

  1. Effect of vitreous length and trephine size disparity on post-DALK refractive status.

    PubMed

    Javadi, Mohammad Ali; Feizi, Sepehr; Rastegarpour, Ali

    2011-04-01

    To evaluate the effect of vitreous length (distance between posterior lens surface and vitreoretinal interface) and donor-recipient disparity on the refraction and keratometric astigmatism after deep anterior lamellar keratoplasty (DALK). In this retrospective comparative study, 85 eyes of 83 patients with keratoconus underwent DALK using the big-bubble technique. A 0.25-mm oversize donor was used for a vitreous length of ≥ 16.0 mm, and a 0.50-mm oversize donor for a vitreous length of <16.0 mm. At least 3 months after complete suture removal, spherical equivalent refractive error (SE), keratometric astigmatism, and mean keratometry were compared between the 2 groups. Multiple regression analysis was performed in group 1 to investigate the correlation between vitreous length and SE, between vitreous length and keratometric astigmatism, and between mean keratometry and SE. Mean patient age was 26.5 ± 7.7 years, and they were followed for 22 ± 10 months postoperatively. Seventy-five eyes received a 0.25-mm oversize donor (group 1), and 10 had a donor oversized by 0.50 mm (group 2). Compared with group 1, the patients of group 2 had a significantly steeper cornea (46.83 ± 2.0 vs. 48.29 ± 1.9 diopters, respectively; P = 0.01). SE and keratometric astigmatism in group 1 did not significantly differ from those in group 2. In group 1, there was a significant association between vitreous length and SE and between mean keratometry and SE but not between vitreous length and keratometric astigmatism. In DALK, a donor oversized by 0.25 mm is advisable for elongated keratoconic eyes, whereas a 0.50-mm oversize donor is advocated for small ones.

  2. Corneal refractive surgery: Is intracorneal the way to go and what are the needs for technology?

    NASA Astrophysics Data System (ADS)

    Hjortdal, Jesper; Ivarsen, Anders

    2014-02-01

    Corneal refractive surgery aims to reduce or eliminate refractive errors of the eye by changing the refractive power of the cornea. For the last 20 years controlled excimer laser ablation of corneal tissue, either directly from the corneal stromal surface or from the corneal interior after creation of a superficial corneal flap has become widely used to correct myopia, hyperopia, and astigmatism. Recently, an intrastromal refractive procedure whereby a tissue lenticule is cut free in the corneal stroma by a femtosecond laser and removed through a small peripheral incision has been introduced. This procedure avoids creation of a corneal flap and the potential associated risks while avoiding the slow visual recovery of surface ablation procedures. Precise intrastromal femtosecond laser cutting of the fine lenticule requires very controlled laser energy delivery in order to avoid lenticule irregularities, which would compromise the refractive result and visual acuity. This newly introduced all-femtosecond based flap-free intracorneal refractive procedure has been documented to be a predictable, efficient, and safe procedure for correction of myopia and astigmatism. Technological developments related to further improved cutting quality, hyperopic and individualized treatments are desirable.

  3. Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report.

    PubMed

    Nuzzi, Raffaele; Monteu, Francesca; Tridico, Federico

    2017-01-01

    Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions - with the consequent need for cross-linking - intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.

  4. Corneal aberrations in keratoconic eyes: influence of pupil size and centering

    NASA Astrophysics Data System (ADS)

    Comastri, S. A.; Perez, L. I.; Pérez, G. D.; Martin, G.; Bianchetti, A.

    2011-01-01

    Ocular aberrations vary among subjects and under different conditions and are commonly analyzed expanding the wavefront aberration function in Zernike polynomials. In previous articles, explicit analytical formulas to transform Zernike coefficients of up to 7th order corresponding to an original pupil into those related to a contracted displaced new pupil are obtained. In the present paper these formulas are applied to 20 keratoconic corneas of varying severity. Employing the SN CT1000 topographer, aberrations of the anterior corneal surface for a pupil of semi-diameter 3 mm centered on the keratometric axis are evaluated, the relation between the higher-order root mean square wavefront error and the index KISA% characterizing keratoconus is studied and the size and centering of the ocular photopic natural pupil are determined. Using these data and the transformation formulas, new coefficients associated to the photopic pupil size are computed and their variation when coordinates origin is shifted from the keratometric axis to the ocular pupil centre is analyzed.

  5. Femtosecond Laser-assisted Arcuate Keratotomy Versus Toric IOL Implantation for Correcting Astigmatism.

    PubMed

    Yoo, Aeri; Yun, Samyoung; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon

    2015-09-01

    To evaluate the clinical efficacy and safety of femtosecond laser-assisted arcuate keratotomy (FS-AK) versus toric intraocular lens (IOL) implantation for correcting astigmatism in patients with cataract. A retrospective chart review was performed. All patients had senile cataracts with corneal astigmatism (range: +1.00 to +3.00 diopters [D]) before cataract surgery. Twenty-five patients agreed to undergo toric IOL implantation (the toric IOL group). Twenty-three patients did not agree to undergo toric IOL implantation despite astigmatism; however, these patients were not satisfied with their remaining astigmatism following cataract surgery and requested astigmatism correction using FS-AK (the FS-AK group). Visual acuity and intraocular pressure were evaluated, and automated refraction, keratometry, and slit-lamp examinations were performed at 1 day, 1 week, 1 month, and 5 months after surgery. Refractive astigmatism decreased in both groups. The mean preoperative and postoperative refractive cylinders were 1.71 ± 1.15 and 0.78 ± 1.06 D, respectively, in the FS-AK group (P < .001) and 1.67 ± 0.13 and 0.83 ± 0.097 D, respectively, in the toric IOL group (P < .001). There were no statistically significant differences between groups at any time during the follow-up period. FS-AK is a fast, customizable, adjustable, precise, and safe procedure for reducing refractive errors in patients with residual astigmatism after cataract surgery. The results of this procedure are comparable to the toric IOL. Copyright 2015, SLACK Incorporated.

  6. Comparison of accelerated and conventional corneal collagen cross-linking for progressive keratoconus.

    PubMed

    Cınar, Yasin; Cingü, Abdullah Kürşat; Türkcü, Fatih Mehmet; Çınar, Tuba; Yüksel, Harun; Özkurt, Zeynep Gürsel; Çaça, Ihsan

    2014-09-01

    To compare outcomes of accelerated and conventional corneal cross-linking (CXL) for progressive keratoconus (KC). Patients were divided into two groups as the accelerated CXL group and the conventional CXL group. The uncorrected distant visual acuity (UDVA), corrected distant visual acuity (CDVA), refraction and keratometric values were measured preoperatively and postoperatively. The data of the two groups were compared statistically. The mean UDVA and CDVA were better at the six month postoperative when compared with preoperative values in two groups. While change in UDVA and CDVA was statistically significant in the accelerated CXL group (p = 0.035 and p = 0.047, respectively), it did not reach statistical significance in the conventional CXL group (p = 0.184 and p = 0.113, respectively). The decrease in the mean corneal power (Km) and maximum keratometric value (Kmax) were statistically significant in both groups (p = 0.012 and 0.046, respectively in the accelerated CXL group, p = 0.012 and 0.041, respectively, in the conventional CXL group). There was no statistically significant difference in visual and refractive results between the two groups (p > 0.05). Refractive and visual results of the accelerated CXL method and the conventional CXL method for the treatment of KC in short time period were similar. The accelerated CXL method faster and provide high throughput of the patients.

  7. Preliminary results of a computerized Placido disk surgical corneal topographer

    NASA Astrophysics Data System (ADS)

    Carvalho, Luis A.; Tonissi, S. A.; Castro, Jarbas C.

    1999-06-01

    We have developed a novel instrument for computerized corneal topography during surgery. The instrument measures a region of approximately 7 mm in diameter, providing the surgeon with precise values of power and astigmatism. The system is based on a Placido Disc projecting system, which is attached to the objective lens of the surgical microscope. The Placido Disc pattern is reflected by a 50% beam splitter attached to the body of the microscope. At the beam splitter we installed our home-made adaptor and a CCD monochromatic high resolution camera. A high quality frame grabber is installed on a PC and images are digitized at a 480x640 resolution. Algorithms based on image processing techniques were implemented for edge detection of pattern. Calibrating curves based on 4 spherical surfaces were generated and approximately 3600 points were calculated for each exam. Preliminary measurements on 10 healthy corneas were compared with the measurements made on an EyeSys Corneal Topographer. Mean deviation was 0.05 for radius of curvature, 0.24 D for power and 5 degrees for cylinder. This system, with some improvements, may be successfully used to diminish high post surgical astigmatisms in surgeries such as cataract and corneal transplant. This system could also be used to gather preoperative data in corneal topography assisted LASIK.

  8. A clinical study to evaluate the results after toric intraocular lens implantation in cases of corneal astigmatism.

    PubMed

    Moulick, P S; Mohindra, V K; Gurunadh, V S; Patel, Parth; Gupta, Sandeep; Khan, M A

    2018-04-01

    Modern day cataract surgery aims at a spectacle free vision which becomes difficult in cases with pre-operative astigmatism more than 1.5 D. Implantation of toric intra-ocular lenses (IOL) after phacoemulsification in such eyes is one of the ways to counteract this problem. Thirty eyes with pre-operative astigmatism between 1.5 D and 4.5 D were implanted with toric IOLs following uneventful phaco-emulsification. The estimation of the axis of implantation of this toric IOL included calculating the surgically induced astigmatism (SIA) of the surgeon. Post-operatively, 20 (66.67%) patients had a visual acuity 6/9 or better and 17 (57%) had a visual acuity of 6/6 at 12 weeks. The mean postoperative uncorrected visual acuity (UCVA) was 0.12 ± 0.15 at 12 weeks. The difference between means of preoperative best corrected visual acuity (BCVA) LogMAR and postoperative UCVA at 12 wk LogMAR was found to be statistically significant at p  = 0.001. Mean (SD) scores of pre-op astigmatism of study group was -2.20 (0.67) and residual astigmatism was -0.32 (0.44). The difference between means of pre-op astigmatism and residual astigmatism in the study group was significant at p  = 0.001 with 95% CI -2.22 to -1.50. This significant difference was because of the toric IOL implantation.

  9. Changes in Astigmatism, Densitometry, and Aberrations After SMILE for Low to High Myopic Astigmatism: A 12-Month Prospective Study.

    PubMed

    Pedersen, Iben Bach; Ivarsen, Anders; Hjortdal, Jesper

    2017-01-01

    To evaluate 12-month changes in refraction, visual outcome, corneal densitometry, and postoperative aberrations after small incision lenticule extraction (SMILE) for myopic astigmatism. This 12-month prospective clinical trial comprised 101 eyes (101 patients) treated with SMILE for myopic astigmatism with cylinder of 0.75 to 4.00 diopters (D). The preoperative, 1-week, and 1-, 3-, 6-, 9-, and 12-month examinations included measurement of manifest refraction, uncorrected distance visual acuity (UDVA), and corrected (CDVA) distance visual acuity. Astigmatic error vector analysis was performed using Al-pin's method. Densitometry and aberrations were evaluated with Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany). Preoperative spherical equivalent averaged -6.78 ± 1.90 D with 1.81 ± 1.00 D in cylinder correction. After 12 months, 74% and 93% of the eyes were within ±0.50 and ±1.00 D of the attempted refraction, respectively. The logMAR UDVA and CDVA averaged 0.03 ± 0.16 and -0.08 ± 0.09, respectively. Vector analysis showed a with-the-rule undercorrection at 12 months with a mean difference vector of 0.31 D @ 91°. There was a minor counterclockwise rotation of the axis, with an arithmetic angle of error of 0.34° ± 14°. An undercorrection of approximately 11% per diopter of attempted correction was seen at 12 months. Spherical aberrations, coma, and higher order aberrations remained stable during the postoperative period (P < .09). After 12 months, no increase in densitometry could be identified. Treatment of astigmatism with SMILE seems to be predictable and effective, but with an astigmatic undercorrection of approximately 11% and a small counterclockwise rotation of the axis. [J Refract Surg. 2017;33(1):11-17.]. Copyright 2017, SLACK Incorporated.

  10. Single-step transepithelial photorefractive keratectomy in myopia and astigmatism: 18-month follow-up.

    PubMed

    Adib-Moghaddam, Soheil; Soleyman-Jahi, Saeed; Salmanian, Bahram; Omidvari, Amir-Houshang; Adili-Aghdam, Fatemeh; Noorizadeh, Farsad; Eslani, Medi

    2016-11-01

    To evaluate the long-term quantitative and qualitative optical outcomes of 1-step transepithelial photorefractive keratectomy (PRK) to correct myopia and astigmatism. Bina Eye Hospital, Tehran, Iran. Prospective interventional case series. Eyes with myopia with or without astigmatism were evaluated. One-step transepithelial PRK was performed with an aberration-free aspheric optimized profile and the Amaris 500 laser. Eighteen-month follow-up results for refraction, visual acuities, vector analysis, higher-order aberrations, contrast sensitivity, postoperative pain, and haze grade were assessed. The study enrolled 146 eyes (74 patients). At the end of follow-up, 93.84% of eyes had an uncorrected distance visual acuity of 20/20 or better and 97.94% of eyes were within ±0.5 diopter of the targeted spherical refraction. On vector analysis, the mean correction index value was close to 1 and the mean index of success and magnitude of error values were close to 0. The achieved correction vector was on an axis counterclockwise to the axis of the intended correction. Photopic and mesopic contrast sensitivities and ocular and corneal spherical, cylindrical, and corneal coma aberrations significantly improved (all P < .001). A slight amount of trefoil aberration was induced (P < .001, ocular aberration; P < .01, corneal aberration). No eye lost more than 1 line of corrected distance visual acuity. No eye had a haze grade of 2+ degrees or higher throughout the follow-up. Eighteen-month results indicate the efficacy and safety of transepithelial PRK to correct myopia and astigmatism. It improved refraction and quality of vision. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Surgical device for supporting corneal suturing

    NASA Astrophysics Data System (ADS)

    Ventura, Liliane; Oliveira, Gunter C. D.; De Groote, Jean-Jacques; Sousa, Sidney J. F.; Saia, Paula

    2009-02-01

    A system for ophthalmic surgery support has been developed in order to minimize the residual astigmatism due to the induced irregular shape of the cornea by corneal suture. The system projects 36 light spots, from LEDs, displayed in a precise circle at the lachrymal film of the examined cornea. The displacement, the size and deformation of the reflected image of these light spots are analyzed providing the keratometry and the circularity of the suture. Measurements in the range of 32D - 55D (up to 23D of astigmatism are possible to be obtained) and a self-calibration system has been designed in order to keep the system calibrated. Steel precision spheres have been submitted to the system and the results show 99% of correlation with the fabricant's nominal values. The system has been tested in 13 persons in order to evaluate its clinical applicability and has been compared to a commercial keratometer Topcon OM-4. The correlation factors are 0,92 for the astigmatism and 0.99 for the associated axis. The system indicates that the surgeon should achieve circularity >=98% in order to do not induce astigmatisms over 3D.

  12. Early visual outcomes and optical quality after femtosecond laser small-incision lenticule extraction for myopia and myopic astigmatism correction of over -10 dioptres.

    PubMed

    Qin, Bing; Li, Meiyan; Chen, Xun; Sekundo, Walter; Zhou, Xingtao

    2018-05-01

    To investigate early visual and refractive outcomes, corneal stability and optical quality after femtosecond laser small-incision lenticule extraction (SMILE) for treating myopia and myopic astigmatism over -10 D. Thirty eyes (30 patients) with myopia and myopic astigmatism of over -10 D were treated with VisuMax ® femtosecond laser (version 3.0; Carl Zeiss Meditec AG, Jena, Germany). Six months postoperative safety, efficacy and predictability were evaluated. Corneal Scheimpflug topography was measured preoperatively, 1 day, 3 months and 6 months postoperatively. Wavefront aberrations were measured preoperatively, 3 months and 6 months postoperatively. Six months postoperatively, LogMAR uncorrected and corrected distance visual acuity (CDVA) were -0.013 ± 0.086 and -0.073 ± 0.069, respectively. 73% (97%) of eyes were within 0.5 (1) D of target refraction. No eyes lost CDVA, 43% (13 eyes) gained one line and 7% (two eyes) gained two lines. Mean corneal back curvature (KMB) and posterior central elevation (PCE) did not change significantly comparing preoperative and 6 months postoperative data (p = 0.91 and 0.77, respectively). Comparing 1 day with 6 months postoperative data, central corneal thickness (CCT), mean corneal front curvature (KMF), KMB and PCE did not change significantly (p = 0.27, 0.07, 0.52, 0.71, respectively). Total higher-order aberration (HOA), spherical aberration and coma increased significantly (p < 0.01) but trefoil remained stable (p = 0.49). Our results indicate that SMILE can correct myopia and myopic astigmatism of over -10 D predictably. No early ectasia was observed. Long-term changes in visual quality and corneal stability require further investigation. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Corneal lenticular wrinkling after automated lamellar keratoplasty.

    PubMed

    Steinemann, T L; Denton, N C; Brown, M F

    1998-10-01

    To report complications of automated lamellar keratoplasty in two eyes of two patients. Case reports. Two eyes of two patients underwent automated lamellar keratoplasty for myopia. Both patients complained of visual distortion and glare in the postoperative eye. The postoperative eye of both patients showed evidence of wrinkling of the corneal lenticule accompanied by irregular astigmatism. Patient 1 showed persistent lenticular wrinkling and corneal scarring 2.5 years later. Patient 2 showed evidence of interface scar and overcorrection. The use of a microkeratome can be complicated by lenticular displacement and wrinkling, resulting in visual aberration for the patient.

  14. Clinical efficacy of toric orthokeratology in myopic adolescent with moderate to high astigmatism.

    PubMed

    Luo, Ming; Ma, Shengsheng; Liang, Na

    2014-12-01

    To observe the efficacy of toric design orthokera- tology (ortho-k) for correcting myopia and astigmatism in myopic adolescents with moderate to high astigmatism. This was a self-controlled clinical study. Twenty-four subjects (42 eyes) aged 9 to 16 years with myopia of 2.50-6.00 D complicated with rule astigmatism of 1.50-3.50 D were fitted with Lucid Night Toric Ortho-k Lenses (LUCID,KO- REA). The changes in uncorrected visual acuity (UCVA), spherical degree, refraction, axial length (AL), and corneal status were assessed at baseline, 1 night, 1 week, 1 month, 3 months, 6 months, and 1 year after the commencement of ortho-k lens wear. The success rate of the first lens fit was 92.8%. The UCVA after ortho-k wearing was improved significantly compared to the baseline during each visit (all P < 0.01), and became stable 1 month after ortho-k. The manifest myopia was significantly reduced from (-3.41 ± 1.27) D to (-0.41 ± 0.37) D by toric ortho-k and the degree of astigmatism from (-1.81 ± 0.53)D to (-0.41 ± 0.39) D after 1 month of lens wear (P < 0.01). The mean AL was (24.47 ± 0.91) mm at baseline, which did not significantly differ from (24.49 ± 0.87) mm and (24.48 ± 0.94) mm after 6 months and 1 year, respectively, of lens wear (both P > 0.05). Grade 1 corneal staining was observed at 1 week (23.8%), 1 month (21.4%), and 1 year (16.7%) following lens wear, and was improved by lens cleaning, discontinuing lens wear, and moistening the cornea with eye drops. No severe adverse events were reported. The toric ortho-k lens was effective and safe for correction of low to moderate myopia in children with moderate to high astigmatism. The lens also effectively controlled axial length elongation during 1 year of observation. However, the long-term efficacy remains to be elucidated.

  15. Electrolysis-needle cauterization of corneal vessels in patients with lipid keratopathy.

    PubMed

    Wertheim, Michael S; Cook, Stuart D; Knox-Cartwright, Nathaniel E; Van, Dung Le; Tole, Derek M

    2007-02-01

    To describe a technique of corneal vessel occlusion by using electrolysis-needle cautery. A prospective case series of three patients. Corneal vessels were successfully occluded in all patients. Vessels remained occluded during the first 8 months post-cautery follow up. Two patients needed repeat cautery at 9 and 10 months respectively. Patients found the procedure comfortable. There was no post-operative induced astigmatism. The technique of ENC is simple, effective and controlled. This technique compares favorably and may prove to be more versatile than Fine Needle Diathermy in the occlusion of corneal vessels that lead to lipid keratopathy.

  16. Biometric Risk Factors for Corneal Neovascularization Associated with Hydrogel Soft Contact Lens Wear in Korean Myopic Patients

    PubMed Central

    Lee, Dae Seung; Wee, Won Ryang

    2014-01-01

    Purpose To investigate the biometric risk factors for corneal surface complications associated with hydrogel soft contact lens (SCL) fitting in myopic patients in Korea. Methods This is a retrospective case-control study. The records of 124 subjects (124 eyes) who wore SCLs on a daily basis were reviewed. Thirty-one patients (31 eyes) who were diagnosed with corneal neovascularization (NV) while wearing SCLs were included in the complication group. Ninety-three age- and sex-matched patients (93 eyes) who wore SCLs, who did not have corneal NV and who visited our clinic for correction of refractive errors were included in the control group. The degree of spherical equivalent, astigmatism and corneal base curve radius (BCR) were compared in both groups. Results Patients with NV exhibited poorer best corrected visual acuity and more myopia than controls (p = 0.008 and 0.006, respectively). In univariate analysis, highly myopic patients (-9 diopters [D] or higher) were more likely to experience NV (odds ratio [OR], 2.232; 95% confidence interval [CI], 1.602 to 3.105). High astigmatism (≥2 D) increased the risk of complications (OR, 2.717; 95% CI, 1.141 to 6.451). Steep cornea, in which BCR was <7.5 mm, also raised the risk of complications (OR, 4.000; 95% CI, 1.661 to 9.804). Flat cornea was not a risk factor for the development of NV. Conclusions High myopia, high astigmatism, and steep cornea seemed to be risk factors in the development of corneal NV in SCL wearers. PMID:25120337

  17. Biometric risk factors for corneal neovascularization associated with hydrogel soft contact lens wear in Korean myopic patients.

    PubMed

    Lee, Dae Seung; Kim, Mee Kum; Wee, Won Ryang

    2014-08-01

    To investigate the biometric risk factors for corneal surface complications associated with hydrogel soft contact lens (SCL) fitting in myopic patients in Korea. This is a retrospective case-control study. The records of 124 subjects (124 eyes) who wore SCLs on a daily basis were reviewed. Thirty-one patients (31 eyes) who were diagnosed with corneal neovascularization (NV) while wearing SCLs were included in the complication group. Ninety-three age- and sex-matched patients (93 eyes) who wore SCLs, who did not have corneal NV and who visited our clinic for correction of refractive errors were included in the control group. The degree of spherical equivalent, astigmatism and corneal base curve radius (BCR) were compared in both groups. Patients with NV exhibited poorer best corrected visual acuity and more myopia than controls (p = 0.008 and 0.006, respectively). In univariate analysis, highly myopic patients (-9 diopters [D] or higher) were more likely to experience NV (odds ratio [OR], 2.232; 95% confidence interval [CI], 1.602 to 3.105). High astigmatism (≥2 D) increased the risk of complications (OR, 2.717; 95% CI, 1.141 to 6.451). Steep cornea, in which BCR was <7.5 mm, also raised the risk of complications (OR, 4.000; 95% CI, 1.661 to 9.804). Flat cornea was not a risk factor for the development of NV. High myopia, high astigmatism, and steep cornea seemed to be risk factors in the development of corneal NV in SCL wearers.

  18. Analysis of excimer laser radiant exposure effect toward corneal ablation volume at LASIK procedure

    NASA Astrophysics Data System (ADS)

    Adiati, Rima Fitria; Rini Rizki, Artha Bona; Kusumawardhani, Apriani; Setijono, Heru; Rahmadiansah, Andi

    2016-11-01

    LASIK (Laser Asissted In Situ Interlamelar Keratomilieusis) is a technique for correcting refractive disorders of the eye such as myopia and astigmatism using an excimer laser. This procedure use photoablation technique to decompose corneal tissues. Although preferred due to its efficiency, permanency, and accuracy, the inappropriate amount radiant exposure often cause side effects like under-over correction, irregular astigmatism and problems on surrounding tissues. In this study, the radiant exposure effect toward corneal ablation volume has been modelled through several processes. Data collecting results is laser data specifications with 193 nm wavelength, beam diameter of 0.065 - 0.65 cm, and fluence of 160 mJ/cm2. For the medical data, the myopia-astigmatism value, cornea size, corneal ablation thickness, and flap data are taken. The first modelling step is determining the laser diameter between 0.065 - 0.65 cm with 0.45 cm increment. The energy, power, and intensity of laser determined from laser beam area. Number of pulse and total energy is calculated before the radiant exposure of laser is obtained. Next is to determine the parameters influence the ablation volume. Regression method used to create the equation, and then the spot size is substituted to the model. The validation used is statistic correlation method to both experimental data and theory. By the model created, it is expected that any potential complications can be prevented during LASIK procedures. The recommendations can give the users clearer picture to determine the appropriate amount of radiant exposure with the corneal ablation volume necessary.

  19. Repair of Irregularly Irregular Astigmatism by Transepithelial Phototherapeutic Keratectomy.

    PubMed

    Guglielmetti, Stefano; Kirton, Amy; Reinstein, Dan Z; Carp, Glenn I; Archer, Timothy J

    2017-10-01

    To evaluate the outcome of transepithelial phototherapeutic keratectomy (PTK) in the management of irregularly irregular astigmatism. This was a case series of two patients who underwent transepithelial PTK for irregularly irregular astigmatism. In the first case, the patient complained of diplopia due to corneal scarring caused by a metallic foreign body injury. The topography demonstrated irregularly irregular astigmatism with significant asymmetry in the inferotemporal to superonasal axis. In the second case, the patient complained of blurred vision and ghosting caused by significant central epithelial ingrowth through a buttonhole LASIK flap, which was causing a localized irregularity on topography. Due to the localized nature of the irregularities, a transepithelial PTK treatment was preferred to custom ablation given the degree of epithelial masking present. Transepithelial PTK was performed in both cases using the Schwind Amaris 500E excimer laser (Schwind eye-tech-solutions, Kleinostheim, Germany) and an 8-mm optical zone. The ablation depth was planned to reach the depth of the epithelium using a stepwise protocol, reviewing the pattern of the remaining epithelium and regularity of the stromal surface between each ablation. A marked improvement in the regularity of the topography was achieved in both cases, with only regular astigmatism remaining. Both patients reported a subjective improvement in quality of vision and the corrected distance visual acuity improved by one and two lines, respectively. Transepithelial PTK was effective in treating these cases of localized irregularly irregular astigmatism, achieving both objective and subjective improvement in vision. Compensatory epithelial remodeling over the irregularities enabled the transepithelial PTK approach to target the stromal surface irregularities. [J Refract Surg. 2017;33(10):714-719.]. Copyright 2017, SLACK Incorporated.

  20. Comparison of Surgically Induced Astigmatism and Morphologic Features Resulting From Femtosecond Laser and Manual Clear Corneal Incisions for Cataract Surgery.

    PubMed

    Ferreira, Tiago B; Ribeiro, Filomena J; Pinheiro, João; Ribeiro, Paulo; O'Neill, João G

    2018-05-01

    To compare the surgically induced astigmatism (SIA) vector, flattening effect, torque, and wound architecture following femtosecond laser and manual clear corneal incisions (CCIs). In a double-armed, randomized, prospective case series, cataract surgery was performed for 600 eyes using femtosecond laser (300 eyes) or manual (300 eyes) 2.4-mm CCIs in temporal or superior oblique locations. SIA, flattening effect, torque, and the summated vector mean for SIA were calculated. Correlation with individual features was established and incision morphology was investigated by anterior segment optical coherence tomography at 3 months of follow-up. The SIA, flattening effect, and torque were lower in the femtosecond laser group for both incision locations, although the differences were not significant (all P > .05). The femtosecond laser group showed less dispersion of SIA magnitude and flattening effect. Temporal and superior oblique incisions resulted in flattening effect values of -0.11 and -0.21 diopters (D), respectively, in the femtosecond laser group and -0.13 and -0.34 D, respectively, in the manual group. Significant correlations with individual features were only found in the femtosecond laser group, with preoperative astigmatism being the only significant SIA predictor by multiple regression analysis (P = .003). Femtosecond laser CCIs showed less deviation from the intended length, wound enlargement, endothelial misalignment, and Descemet membrane detachments (all P < .037). Femtosecond laser CCIs were more reproducible. Although SIAs were smaller in femtosecond laser CCIs than in manual CCIs for both temporal and superior oblique incisions, the difference was not statistically significant. Association with individual features is highly variable. [J Refract Surg. 2018;34(5):322-329.]. Copyright 2018, SLACK Incorporated.

  1. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    PubMed

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  2. [Implantation of a sulcus-fixated toric additive intraocular lens in a case of high astigmatism after a triple procedure].

    PubMed

    Linz, K; Auffarth, G U; Kretz, F T A

    2014-08-01

    Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D. A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, - 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and - 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to - 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed. Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of

  3. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery: A Systematic Review and Meta-analysis.

    PubMed

    Kessel, Line; Andresen, Jens; Tendal, Britta; Erngaard, Ditte; Flesner, Per; Hjortdal, Jesper

    2016-02-01

    We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were evaluated as surgical complications and residual astigmatism. Postoperative astigmatism is an important cause of suboptimal UCDVA and need for distance spectacles. Toric IOLs may correct for preexisting corneal astigmatism at the time of surgery. We performed a systematic literature search in the Embase, PubMed, and CENTRAL databases within the Cochrane Library. We included randomized clinical trials (RCTs) if they compared toric with non-toric IOL implantation (± relaxing incision) in patients with regular corneal astigmatism and age-related cataracts. We assessed the risk of bias using the Cochrane Risk of Bias tool. We assessed the quality of evidence across studies using the GRADE profiler software (available at: www.gradeworkinggroup.org). We included 13 RCTs with 707 eyes randomized to toric IOLs and 706 eyes randomized to non-toric IOLs; 225 eyes had a relaxing incision. We found high-quality evidence that UCDVA was better in the toric IOL group (logarithm of the minimum angle of resolution [logMAR] mean difference, -0.07; 95% confidence interval [CI], -0.10 to -0.04) and provided greater spectacle independence (risk ratio [RR], 0.51; 95% CI, 0.36-0.71) and moderate quality evidence that toric IOL implantation was not associated with an increased risk of complications (RR, 1.73; 95% CI, 0.60-5.04). Residual astigmatism was lower in the toric IOL group than in the non-toric IOL plus relaxing incision group (mean difference, 0.37 diopter [D]; 95% CI, -0.55 to -0.19). We found that toric IOLs provided better UCDVA, greater spectacle independence, and lower amounts of residual astigmatism than non-toric IOLs even when relaxing incisions were used. Copyright © 2016

  4. Optical coherence tomography-based topography determination of corneal grafts in eye bank cultivation

    NASA Astrophysics Data System (ADS)

    Damian, Angela; Seitz, Berthold; Langenbucher, Achim; Eppig, Timo

    2017-01-01

    Vision loss due to corneal injuries or diseases can be treated by transplantation of human corneal grafts (keratoplasty). However, quality assurance in retrieving and cultivating the tissue transplants is confined to visual and microbiological testing. To identify previous refractive surgery or morphological alterations, an automatic, noncontact, sterile screening procedure is required. Twenty-three corneal grafts have been measured in organ culture with a clinical spectral-domain optical coherence tomographer. Employing a biconic surface fit with 10 degrees of freedom, the radii of curvature and conic constants could be estimated for the anterior and posterior corneal surfaces. Thereupon, central corneal thickness, refractive values, and astigmatism have been calculated. Clinical investigations are required to elaborate specific donor-host matching in the future.

  5. Excimer laser phototherapeutic keratectomy for shield ulcers and corneal plaques in vernal keratoconjunctivitis.

    PubMed

    Cameron, J A; Antonios, S R; Badr, I A

    1995-01-01

    Shield-shaped corneal ulcers and corneal plaques in vernal keratoconjunctivitis are associated with delayed epithelial healing, as well as the risks of infectious keratitis and sterile stromal ulceration. Significant visual impairment due to scarring and irregular astigmatism may result from central corneal lesions. Three eyes with central corneal lesions resulting from vernal keratoconjunctivitis were treated by excimer laser after active vernal keratoconjunctivitis was controlled and inflammatory plaque overlying the shield ulcers was removed. All three eyes showed rapid reepithelialization within 1 week. Spectacle-corrected visual acuity of 20/30 or better was obtained in each eye. In selected patients, excimer laser phototherapeutic keratectomy may be a useful adjunct in the treatment of shield-shaped corneal ulcers and plaques in vernal keratoconjunctivitis.

  6. Implantation of a customized toric intraocular lens for correction of post-keratoplasty astigmatism

    PubMed Central

    Srinivasan, S; Ting, D S J; Lyall, D A M

    2013-01-01

    Purpose To report visual and refractive outcomes, and endothelial cell loss following primary and secondary ‘piggyback' toric intraocular lens (IOL) implantation in patients with high post-penetrating keratoplasty (PK) astigmatism. Methods Prospective case series. Nine eyes of nine patients with post-PK astigmatism were consecutively recruited for implantation of a customized toric IOL. Six underwent simultaneous phacoemulsification (PE) and three pseudophakic eyes had a secondary ‘piggyback' toric IOL implanted in the ciliary sulcus. Mean follow-up time was 17.2±7.7 months. Pre- and post-operative uncorrected (UDVA) and best-corrected (BDVA) distance visual acuities and refractive errors were collected for comparison. Cartesian astigmatic vectors were calculated to identify a change in the magnitude of astigmatism pre- compared to postoperatively. Pre- and post-operative endothelial cell counts were also collected for analysis. Results UDVA (logMAR) improved from 1.13±0.51 preoperatively to 0.48±0.24 postoperatively (P-value=0.003). There was no significant change in BDVA (P-value=0.905) from 0.31±0.27 to 0.26±0.19. Corneal astigmatism preoperatively was 6.57±4.40 diopters (D). Post-operative refractive cylinder was 0.83±1.09 D compared to 3.89±4.01 D preoperatively (P=0.039). Analysis of astigmatic Cartesian x and y coordinates found a significant reduction postoperatively compared to preoperatively (P=0.005 and P=0.002), respectively. Mean endothelial cell loss was 9.9%. Conclusion: Implantation of a customized primary or secondary ‘piggyback' toric IOL serves as an effective modality in treating patients with high post-PK astigmatism. PMID:23348728

  7. Astigmatism

    MedlinePlus

    ... change the shape of the cornea surface to eliminate astigmatism, along with nearsightedness or farsightedness. ... contact lenses. Laser vision correction can most often eliminate, or greatly reduce astigmatism.

  8. LASIK for myopia and astigmatism using the SCHWIND AMARIS excimer laser: an international multicenter trial.

    PubMed

    Arbelaez, Maria Clara; Aslanides, Ioannis M; Barraquer, Carmen; Carones, Francesco; Feuermannova, Alena; Neuhann, Tobias; Rozsival, Pavel

    2010-02-01

    To assess the efficacy, predictability, and safety of LASIK for the surgical correction of low to moderate myopia with astigmatism using the SCHWIND AMARIS excimer laser. Six international study sites enrolled 358 eyes with a manifest refraction spherical equivalent (MRSE) from -0.50 to -7.38 diopters (D) (mean sphere: -3.13+/-1.58 D) with up to -5.00 D of astigmatism (mean: -0.69+/-0.67 D). All eyes underwent treatment with the nonwavefront-guided aspheric algorithm of the SCHWIND AMARIS excimer laser. All eyes were targeted for emmetropia. Refractive outcomes and corneal higher order aberrations were analyzed pre- and postoperatively. Visual quality was assessed using photopic and mesopic contrast sensitivity. Six-month postoperative outcomes are reported. At 6 months postoperative, the MRSE for all eyes was -0.21+/-0.20 D, and 96% (343/358) of eyes had MRSE within +/-0.50 D. Uncorrected visual acuity was 20/20 or better in 98% (351/358) of eyes, and no eyes lost 2 or more lines of best spectacle-corrected visual acuity. The total corneal higher order aberrations root-mean-square increased by 0.09 microm, spherical aberration increased by 0.08 microm, and coma increased by 0.04 microm postoperatively. Photopic and mesopic contrast sensitivity did not change 6 months postoperatively. Treatment of myopia with astigmatism using the SCHWIND AMARIS excimer laser is safe, efficacious, predictable, and maintains visual quality.

  9. Randomized Trial Comparing Amniotic Membrane Transplantation with Lamellar Corneal Graft for the Treatment of Corneal Thinning.

    PubMed

    de Farias, Charles C; Allemann, Norma; Gomes, José Á P

    2016-04-01

    There are few studies comparing different surgical procedures for the treatment of corneal thinning. Lamellar corneal transplantation (LCT) has been reported to be efficient, but its results can be jeopardized by allograft rejection, opacification, or high astigmatism. Amniotic membrane transplantation (AMT) has been considered a good alternative, but it is not as resistant as LCT and the tissue can be reabsorbed after surgery. A prospective, randomized, interventional, and comparative study of consecutive patients with corneal thinning over 6 months was performed. Ophthalmological examination was performed before transplant surgery and then repeated 1, 7, 15, 30, 90, and 180 days after surgery and ultrasound biomicroscopy was performed before and then 30, 90, and 180 days after surgery to assess corneal thinning. Herpes simplex infection was the main cause of corneal thinning (9 eyes), followed by surgery (cataract, glaucoma, 5 cases), rheumatoid arthritis (1), chemical burn (1), perforating trauma (1), previous band keratopathy treatment (1), and Stevens-Johnson syndrome (1). Although all patients showed significant increase in final thickness in the area of thinning, it was higher in those submitted to LCT at 180 days postoperatively. Regardless of the surgical technique, all patients showed epithelialization. Patients undergoing AMT showed an 89% decrease in neovascularization. Final corrected distance visual acuity was better in patients submitted to AMT. LCT proved to be the best option for treating corneal thinning. AMT represents an alternative that allows good visual recovery but does not restore corneal thickness as efficiently as LCT.

  10. Corneal modeling for analysis of photorefractive keratectomy

    NASA Astrophysics Data System (ADS)

    Della Vecchia, Michael A.; Lamkin-Kennard, Kathleen

    1997-05-01

    Procedurally, excimer photorefractive keratectomy is based on the refractive correction of composite spherical and cylindrical ophthalmic errors of the entire eye. These refractive errors are inputted for correction at the corneal plane and for the properly controlled duration and location of laser energy. Topography is usually taken to correspondingly monitor spherical and cylindrical corneorefractive errors. While a corneal topographer provides surface morphologic information, the keratorefractive photoablation is based on the patient's spherical and cylindrical spectacle correction. Topography is at present not directly part of the procedural deterministic parameters. Examination of how corneal curvature at each of the keratometric reference loci affect the shape of the resultant corneal photoablated surface may enhance the accuracy of the desired correction. The objective of this study was to develop a methodology to utilize corneal topography for construction of models depicting pre- and post-operative keratomorphology for analysis of photorefractive keratectomy. Multiple types of models were developed then recreated in optical design software for examination of focal lengths and other optical characteristics. The corneal models were developed using data extracted from the TMS I corneal modeling system (Computed Anatomy, New York, NY). The TMS I does not allow for manipulation of data or differentiation of pre- and post-operative surfaces within its platform, thus models needed to be created for analysis. The data were imported into Matlab where 3D models, surface meshes, and contour plots were created. The data used to generate the models were pre- and post-operative curvatures, heights from the corneal apes, and x-y positions at 6400 locations on the corneal surface. Outlying non-contributory points were eliminated through statistical operations. Pre- and post- operative models were analyzed to obtain the resultant changes in the corneal surfaces during PRK

  11. Comparison of Wavelight Allegretto Eye-Q and Schwind Amaris 750S excimer laser in treatment of high astigmatism.

    PubMed

    Bohac, Maja; Biscevic, Alma; Koncarevic, Mateja; Anticic, Marija; Gabric, Nikica; Patel, Sudi

    2014-10-01

    To compare functional outcomes of Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S excimer laser for astigmatism between 2 and 7 diopters(D). Prospective comparative non-randomized case series of 480 eyes assigned in two laser groups and further divided into myopic and mixed astigmatism subgroups. All treatments were centered on corneal vertex. One-year results were compared between the groups. Statistical analysis was performed using z-test. Both Allegretto and Amaris postoperative uncorrected distance visual acuity (UDVA) improved in comparison to preoperative corrected distance visual acuity (CDVA). The difference was significant in the Allegretto group for myopic astigmatism (p = 0.017). There was no difference in postoperative UDVA between lasers. Average sphere decreased in all groups for both lasers (p < 0.001) without difference in effectiveness of spherical correction between lasers for both groups. In Allegretto, average cylinder decreased from -3.30D to -0.55D in myopic astigmatism (p < 0.001) and from -3.84D to -0.85D in mixed astigmatism (p < 0.001). In Amaris average cylinder decreased from -3.21D to -0.43D in myopic astigmatism (p < 0.001) and from -3.66D to -0.58D in mixed astigmatism (p < 0.001). Amaris group had less residual astigmatism (myopic astigmatism p = 0.023, mixed astigmatism p < 0.001). Mean spherical aberration shifted from positive to negative in mixed astigmatism for both lasers. Both lasers are effective in terms of UDVA, CDVA, spherical correction, and preservation of high-order aberrations. However, Amaris was more effective in cylinder correction.

  12. Comparative evaluation of aspheric toric intraocular lens implantation and limbal relaxing incisions in eyes with cataracts and ≤3 dioptres of astigmatism.

    PubMed

    Lam, Douglas K T; Chow, Vanissa W S; Ye, Cong; Ng, Paul Ka-Fai; Wang, Zheng; Jhanji, Vishal

    2016-02-01

    To compare the visual outcomes of aspheric toric intraocular lens (IOL) implantation and limbal relaxing incisions (LRI) for management of coexisting age-related cataracts and astigmatism. In this prospective study, sixty eyes of 60 patients with visually significant cataract and coexisting corneal astigmatism ≤3 dioptres (D) were randomised to undergo phacoemulsification with either aspheric toric IOL or aspheric monofocal IOL with LRI. The main outcome measures were postoperative 3-month uncorrected visual acuity (UCVA), contrast sensitivity, rotational stability of the toric IOL and spectacle independence. The postoperative UCVA, contrast sensitivity and refractive astigmatism were significantly better than the baseline measurements for both groups (p≤0.001). There was no significant difference detected for these parameters between LRI and toric IOL groups postoperatively (p≥0.119). At both postoperative month 1 and 3, the percentages of eyes in need of spectacles were lower in toric group than LRI group (p≤0.030). IOL misalignment was noted in three eyes in the toric IOL group (mean misalignment 7.67±4.04°). On vector analysis, magnitude of error (ME) was negative in the LRI group indicating undercorrection, whereas the ME was close to zero for toric group. Both toric IOL implantation and LRI were effective in correcting corneal astigmatism ≤3 D during phacoemulsification, while LRI tended to undercorrect astigmatism. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Microkeratome-Assisted Anterior Lamellar Keratoplasty for the Correction of High-Degree Postkeratoplasty Astigmatism.

    PubMed

    Gutfreund, Shay; Leon, Pia; Busin, Massimo

    2017-07-01

    To describe the surgical technique and report the outcomes of patients treated with microkeratome-assisted anterior lamellar keratoplasty (MALK) for the correction of high-degree postkeratoplasty astigmatism. Four eyes of 2 patients with extremely high (>10 D) and irregular [surface asymmetry index >1.0 D] post-penetrating keratoplasty astigmatism occurring after complete suture removal underwent MALK and were followed for at least 3 years after the procedure. In all cases, 250-µm lamellar keratectomy was performed, followed by 2 full-thickness incisions through the penetrating keratoplasty scar and the placement of an appropriately sized donor graft, which was secured with a double-running 10-0 nylon suture. All sutures were removed in all eyes within 1 year from surgery. Corrected distance visual acuity, refraction, corneal topography, and endothelial cell density were noted at each examination. At the last follow-up examination (3 years or longer after MALK), corrected distance visual acuity had improved to 20/20, refractive astigmatism had decreased to an average of 2.1 D (in all cases within 4.5 D), and the average surface asymmetry index had reduced from 2.27 to 0.56. MALK is an effective and safe technique for the correction of high-degree postkeratoplasty astigmatism.

  14. Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications

    PubMed Central

    Ambrósio, Jr, Renato; Correia, Fernando Faria; Lopes, Bernardo; Salomão, Marcella Q.; Luz, Allan; Dawson, Daniel G.; Elsheikh, Ahmed; Vinciguerra, Riccardo; Vinciguerra, Paolo; Roberts, Cynthia J.

    2017-01-01

    Background: Ectasia development occurs due to a chronic corneal biomechanical decompensation or weakness, resulting in stromal thinning and corneal protrusion. This leads to corneal steepening, increase in astigmatism, and irregularity. In corneal refractive surgery, the detection of mild forms of ectasia pre-operatively is essential to avoid post-operative progressive ectasia, which also depends on the impact of the procedure on the cornea. Method: The advent of 3D tomography is proven as a significant advancement to further characterize corneal shape beyond front surface topography, which is still relevant. While screening tests for ectasia had been limited to corneal shape (geometry) assessment, clinical biomechanical assessment has been possible since the introduction of the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Buffalo, USA) in 2005 and the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) in 2010. Direct clinical biomechanical evaluation is recognized as paramount, especially in detection of mild ectatic cases and characterization of the susceptibility for ectasia progression for any cornea. Conclusions: The purpose of this review is to describe the current state of clinical evaluation of corneal biomechanics, focusing on the most recent advances of commercially available instruments and also on future developments, such as Brillouin microscopy. PMID:28932334

  15. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    PubMed Central

    Piñero, David P.; Camps, Vicente J.; Ramón, María L.; Mateo, Verónica; Pérez-Cambrodí, Rafael J.

    2015-01-01

    AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). RESULTS PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors. PMID:26085998

  16. Corneal collagen crosslinking for corneal ectasia of post-LASIK: one-year results

    PubMed Central

    Li, Gang; Fan, Zheng-Jun; Peng, Xiu-Jun

    2012-01-01

    AIM To evaluate the efficacy and safety of corneal collagen crosslinking (CXL) to prevent the progression of post-laser in situ keratomileusis (LASIK) corneal ectasia. METHODS In a prospective, nonrandomized, single-centre study, CXL was performed in 20 eyes of 11 patients who had LASIK for myopic astigmatism and subsequently developed keratectasia.The procedure included instillation of 0.1% riboflavin-20% dextrane solution 30 minutes before UVA irradiation and every 5 minutes for an additional 30 minutes during irradiation. The eyes were evaluated preoperatively and at 1-, 3-, 6-, and 12-month intervals. The complete ophthalmologic examination comprised uncorrected visual acuity, best spectacle-corrected visual acuity, endothelial cell count, ultrasound pachymetry, corneal topography, and in vivo confocal microscopy. RESULTS CXL appeared to stabilise or partially reverse the progression of post-LASIK corneal ectasia without apparent complication in our cohort. UCVA and BCVA improvements were statistically significant(P<0.05) beyond 12 months after surgery (improvement of 0.07 and 0.13 logMAR at 1 year, respectively). Mean baseline flattest meridian keratometry and mean steepest meridian keratometry reduction (improvement of 2.00 and 1.50 diopters(D), respectively) were statistically significant (P<0.05) at 12 months postoperatively. At 1 year after CXL, mean endothelial cell count did not deteriorate. Mean thinnest cornea pachymetry increased significantly. CONCLUSION The results of the study showed a long-term stability of post-LASIK corneal ectasia after crosslinking without relevant side effects. It seems to be a safe and promising procedure to stop the progression of post-LASIK keratectasia, thereby avoiding or delaying keratoplasty. PMID:22762048

  17. Comparison of surgically induced astigmatism following different glaucoma operations.

    PubMed

    Tanito, Masaki; Matsuzaki, Yukari; Ikeda, Yoshifumi; Fujihara, Etsuko

    2017-01-01

    To compare surgically induced astigmatism (SIA) among glaucomatous eyes treated with trabeculectomy (LEC), EX-PRESS ® shunt (EXP), ab externo trabeculotomy (exLOT), or microhook ab interno trabeculotomy (μLOT). Eighty right eyes of 80 subjects who underwent LEC (n=20), EXP (n=20), exLOT (n=20), or μLOT (n=20) were included. The dataset including the best-corrected visual acuity (BCVA), intraocular pressure (IOP), and keratometry recordings preoperatively and 3 months postoperatively was collected by chart review. The means of the vector magnitude, vector meridian, and arithmetic magnitude of the preoperative and postoperative astigmatism and SIA were calculated. The correlations among the SIA magnitude, postoperative BCVA, and IOP were assessed. The mean astigmatic arithmetic magnitudes did not differ significantly ( P =0.0732) preoperatively among the four groups, but the magnitude was significantly ( P =0.0002) greater in the LEC group than the other groups postoperatively. The mean SIA vectors were calculated to be 1.01 D at 56°, 0.62 D at 74°, 0.23 D at 112°, and 0.12 D at 97° for the LEC, EXP, exLOT, and μLOT groups, respectively. The mean SIA arithmetic magnitudes were significantly ( P <0.0001) greater in the LEC group than the other groups. Three months postoperatively, the SIA magnitude was correlated positively with the logarithm of the minimum angle of resolution (logMAR) BCVA ( r =0.3538) and negatively with the IOP ( r =-0.3265); the logMAR BCVA was correlated negatively with the IOP ( r =-0.3105). EXP, exLOT, and μLOT induce less corneal astigmatism than LEC in the early postoperative period.

  18. Internal Astigmatism in Myopes and Non-myopes: Compensation or Constant?

    PubMed Central

    Manny, Ruth E.; Deng, Li; Gwiazda, Jane; Hyman, Leslie; Weissberg, Erik; Scheiman, Mitchell; Fern, Karen D.

    2016-01-01

    Purpose To examine internal astigmatism (IA) in myopes and non-myopes using a new method to assess compensation of corneal astigmatism (CA) by IA, to look for predictors of high IA in young adult myopes and determine if as CA changes IA changes to reduce refractive astigmatism (RA) in an active compensatory process in myopes. Methods Right eye keratometry and cycloplegic autorefraction were measured annually over 14 years in 367 myopes and once in 204 non-myopes age- (mean 21.91 years ± 1.47), gender-, and ethnicity-matched to myopes at year 12. CA and RA at the corneal plane were expressed as J0, J45. IA = RA - CA. Inverse power transformation provided cylinder power and axis of IA for the compensation factor (IA/CA). Analyses included: 1) paired and unpaired t-tests (refractive data), 2) chi-square tests (distributions of compensation factor), 3) logistic regression analysis (predictors of high IA), and 4) linear mixed models (time effect on RA, CA and IA). Results The magnitude of IAJ0 varied by refractive error (myopes −0.25 ±0.24 vs non-myopes −0.32 ± 0.21, p<0.001). Compensation of CA by IA was poorer in myopes than non-myopes (χ2 p<0.001). When matched by CA, compensation remained poorer in myopes than non-myopes (χ2 all p≤ 0.04). Within each refractive group compensation was better when CA was low than high (χ2 p<0.001). When CA was low in myopes, high IA (≥1.00D) was less likely (p=0.01). Longitudinal follow-up of myopes found no evidence for an active compensatory role for IA as CA increased over time. There were differences in IAJ0 by ethnicity over time (p<0.0001). Conclusions In myopic and non-myopic eyes with low amounts of CA, IA may reduce CA’s contribution to RA, but IA is not a constant. However, there is no evidence for an active compensatory role for IA reducing CA in myopes. PMID:27564515

  19. Contact lens fitting in a patient with Alport syndrome and posterior polymorphous corneal dystrophy: a case report.

    PubMed

    Rosa, Juliana Maria da Silva; Andrade Sobrinho, Marcelo Vicente de; Lipener, César

    2016-02-01

    Alport Syndrome is a hereditary disease that is caused by a gene mutation and affects the production of collagen in basement membranes; this condition causes hemorrhagic nephritis associated with deafness and ocular changes. The X-linked form of this disease is the most common and mainly affects males. Typical ocular findings are dot-and-fleck retinopathy, anterior lenticonus, and posterior polymorphous corneal dystrophy. Some cases involving polymorphous corneal dystrophy and corneal ectasia have been previously described. Here we present a case report of a 33-year-old female with Alport syndrome, posterior polymorphous corneal dystrophy, and irregular astigmatism, whose visual acuity improved with a rigid gas permeable contact lens.

  20. Astigmatism among myopics and its changes from childhood to adult age: a 23-year follow-up study.

    PubMed

    Pärssinen, Olavi; Kauppinen, Markku; Viljanen, Anne

    2015-05-01

    To study the prevalence of and changes in astigmatism from the onset of myopia at school age. Two hundred and forty myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983-1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Three annual examinations with subjective cycloplegic refraction were performed for 237-238 subjects. Subsequent examinations were performed at the mean ages of 23.2 and 33.9 years for 178 and 163 subjects, and the last examination, including data from prescriptions of different ophthalmologists, for 32 subjects. Corneal topography was studied at baseline, at the 3-year follow-up and at the two adulthood follow-ups. Prevalence and changes in refractive astigmatism (RA), in its polar values J0 and J45, and corneal astigmatism (CA) were studied. Mean RA of the right eye increased during follow-up from 0.26 D (SD) ± 0.30 to 0.79 D ± 0.74. Mean CA was 1.07 D ± 0.74 at study end. The prevalence of RA ≥0.25 or ≥1.00 D increased from 54.9 and 3.8% to 83.4 and 34.4%, respectively. The main direction of the axis of RA and its polar value J0 and CA changed mainly through sphericity, from against the rule (ATR) to with the rule during the follow-up. There was a negative correlation between RA and spherical refraction in the ATR group at end of follow-up. Changes in RA were associated with increase in myopia and with changes in CA. The prevalence and mean amount of RA associated with CA increased, and the axis of astigmatism changed among myopics during the 23-year follow-up. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. The Results of Toric Intraocular Lens Implantation in Patients With Cataract and High Astigmatism After Penetrating Keratoplasty.

    PubMed

    Müftüoğlu, İlkay Klç; Akova, Yonca Aydn; Egrilmez, Sait; Yilmaz, Suzan Guven

    2016-03-01

    To evaluate the results of toric intraocular lens (IOL) implantation in patients with cataract and postpenetrating keratoplasty astigmatism. Seven eyes of 7 patients with cataract and more than 3.5 diopters (D) astigmatism following penetrating keratoplasty were included in this retrospective case series study. All of the eyes underwent phacoemulsification and Acrysof toric IOL (t5-t9) implantation at least 6 months later than the complete suture removal. Corrected visual acuity (CVA), manifest astigmatism, the keratometry measurements, and complications were assessed. The mean preoperative CVA significantly increased (0.7±0.3 [range: 0.3-1.3] logMAR to 0.1±0.04 [range: 0.05-0.15] logMAR; P<0.05) at mean 8.71±4.11 months after the surgery. The mean preoperative corneal astigmatism and the average manifest refractive astigmatism at the last visit were 5.4±0.9 D (range: 4.25-7 D) and 1.6±0.6 D (range: 0.5-2.5 D), respectively. The mean attempted cylinder correction at spectacle plane was 4.3±0.9 D (range: 2.4-4.7 D) whereas the mean cylinder correction was 4.6±0.5 D (range: 3.9-5.9 D), showing a slightly tendency for overcorrection. All eyes (100%) were within 1 D of predicted residual astigmatism. No complication occurred during the follow-up. Toric IOL implantation seems to be an effective, predictable, and safe procedure in patients with cataract formation and high astigmatism after penetrating keratoplasty.

  2. Correlations between corneal and total wavefront aberrations

    NASA Astrophysics Data System (ADS)

    Mrochen, Michael; Jankov, Mirko; Bueeler, Michael; Seiler, Theo

    2002-06-01

    Purpose: Corneal topography data expressed as corneal aberrations are frequently used to report corneal laser surgery results. However, the optical image quality at the retina depends on all optical elements of the eye such as the human lens. Thus, the aim of this study was to investigate the correlations between the corneal and total wavefront aberrations and to discuss the importance of corneal aberrations for representing corneal laser surgery results. Methods: Thirty three eyes of 22 myopic subjects were measured with a corneal topography system and a Tschernig-type wavefront analyzer after the pupils were dilated to at least 6 mm in diameter. All measurements were centered with respect to the line of sight. Corneal and total wavefront aberrations were calculated up to the 6th Zernike order in the same reference plane. Results: Statistically significant correlations (p < 0.05) between the corneal and total wavefront aberrations were found for the astigmatism (C3,C5) and all 3rd Zernike order coefficients such as coma (C7,C8). No statistically significant correlations were found for all 4th to 6th order Zernike coefficients except for the 5th order horizontal coma C18 (p equals 0.003). On average, all Zernike coefficients for the corneal aberrations were found to be larger compared to Zernike coefficients for the total wavefront aberrations. Conclusions: Corneal aberrations are only of limited use for representing the optical quality of the human eye after corneal laser surgery. This is due to the lack of correlation between corneal and total wavefront aberrations in most of the higher order aberrations. Besides this, the data present in this study yield towards an aberration balancing between corneal aberrations and the optical elements within the eye that reduces the aberration from the cornea by a certain degree. Consequently, ideal customized ablations have to take both, corneal and total wavefront aberrations, into consideration.

  3. Comparison of surgically induced astigmatism following different glaucoma operations

    PubMed Central

    Tanito, Masaki; Matsuzaki, Yukari; Ikeda, Yoshifumi; Fujihara, Etsuko

    2017-01-01

    Aim To compare surgically induced astigmatism (SIA) among glaucomatous eyes treated with trabeculectomy (LEC), EX-PRESS® shunt (EXP), ab externo trabeculotomy (exLOT), or microhook ab interno trabeculotomy (μLOT). Subjects and methods Eighty right eyes of 80 subjects who underwent LEC (n=20), EXP (n=20), exLOT (n=20), or μLOT (n=20) were included. The dataset including the best-corrected visual acuity (BCVA), intraocular pressure (IOP), and keratometry recordings preoperatively and 3 months postoperatively was collected by chart review. The means of the vector magnitude, vector meridian, and arithmetic magnitude of the preoperative and postoperative astigmatism and SIA were calculated. The correlations among the SIA magnitude, postoperative BCVA, and IOP were assessed. Results The mean astigmatic arithmetic magnitudes did not differ significantly (P=0.0732) preoperatively among the four groups, but the magnitude was significantly (P=0.0002) greater in the LEC group than the other groups postoperatively. The mean SIA vectors were calculated to be 1.01 D at 56°, 0.62 D at 74°, 0.23 D at 112°, and 0.12 D at 97° for the LEC, EXP, exLOT, and μLOT groups, respectively. The mean SIA arithmetic magnitudes were significantly (P<0.0001) greater in the LEC group than the other groups. Three months postoperatively, the SIA magnitude was correlated positively with the logarithm of the minimum angle of resolution (logMAR) BCVA (r=0.3538) and negatively with the IOP (r=−0.3265); the logMAR BCVA was correlated negatively with the IOP (r=−0.3105). Conclusion EXP, exLOT, and μLOT induce less corneal astigmatism than LEC in the early postoperative period. PMID:29238159

  4. Repeatability data and agreement of keratometry with the VERION system compared to the IOLMaster.

    PubMed

    Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Berta, Andras; Modis, Laszlo

    2015-05-01

    To analyze the repeatability of keratometric and white-to-white (WTW) distance measurements with the VERION Measurement Module (Alcon Laboratories, Inc., Fort Worth, TX) and to compare the measured data to the results of the IOLMaster (Carl Zeiss Meditec, Jena, Germany). Three images were captured with the VERION and the flattest and steepest keratometric data, the astigmatism axis, and the WTW distance were recorded. Subsequently, the axial length, the keratometric data with axis, and the WTW distance were measured with an IOLMaster. The repeatability data of the keratometric value of the VERION System, converted to cross cylinder J0 and J45 vector components, were analyzed. The agreement data for keratometry obtained by the VERION System and the differences regarding keratometric data and WTW distance compared to IOLMaster were calculated. The measurements were conducted in 50 eyes of 50 healthy volunteers (median age: 50.32 years, range: 19.34 to 85.3 years). The flattest and the steepest keratometric data, the diopter of astigmatism, the J0 and J45 vector components, and WTW distance did not differ significantly between devices (P > .05). Intraclass correlation coefficients (range: 0.863 to 0.994) and Cronbach's alpha values (range: 0.950 to 0.998) were high for all parameters measured by the VERION System. The VERION System has high repeatability and agreement with the IOLMaster, making it suitable as an alternative tool in clinical practice. Copyright 2015, SLACK Incorporated.

  5. Ocular residual astigmatism's effect on high myopic astigmatism LASIK surgery

    PubMed Central

    Teus, M A; Arruabarrena, C; Hernández-Verdejo, J L; Cañones, R; Mikropoulos, D G

    2014-01-01

    Purpose To analyze the effect of ocular residual astigmatism (ORA) on the effectiveness of LASIK for treating high myopic astigmatism. Methods This is an observational, cross-sectional study. We studied 116 consecutive myopic eyes with −3 diopters (D) or more of astigmatism that underwent LASIK surgery. The magnitude of uncorrected residual refractive astigmatism 3 months postoperatively was measured. Results The mean preoperative cylinder was −4.0±0.83 D (range, −7.5 to −3 D) and the mean preoperative ORA was 0.82±0.5 D. The mean residual refractive cylinder 3 months postoperatively was −0.78±0.83 D (range, −3 to 0 D). No correlation was found between ORA and the refractive cylinder 3 months postoperatively (P=0.6). Conclusion In eyes with high myopic astigmatism undergoing LASIK, ORA was not correlated with the residual postoperative cylinder. PMID:24971989

  6. Effect of Conus Eccentricity on Visual Outcomes After Intracorneal Ring Segments Implantation in Keratoconus.

    PubMed

    Gatzioufas, Zisis; Panos, Georgios D; Elalfy, Mohamed; Khine, Aye; Hamada, Samer; Lake, Damian; Kozeis, Nikos; Balidis, Miltos

    2018-03-01

    To investigate the potential impact of cone eccentricity on visual outcomes after Keraring (Mediphacos, Belo Horizonte, Brazil) implantation for keratoconus. Nineteen eyes from 19 patients with keratoconus who underwent femtosecond laser-assisted Keraring implantation for keratoconus were included in this retrospective study. Uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), keratometric readings, central corneal thickness, maximum keratometric distance from corneal apex (DKmax), corneal thinnest point from corneal apex (DTh), and coma were evaluated preoperatively and 6 months after the Keraring implantation. DKmax and DTh were used as metrics reflecting the eccentricity of the cone. UDVA, CDVA, keratometric readings, and coma improved at 6 months postoperatively. However, there was no correlation between DKmax or DTh and visual outcomes at 6 months postoperatively. The data did not show any impact of the cone eccentricity on visual outcomes after Keraring implantation for keratoconus at 6 months postoperatively. [J Refract Surg. 2018;34(3):196-200.]. Copyright 2018, SLACK Incorporated.

  7. Influence of the flap on outcomes in corneal refractive surgery with femtosecond laser: SMILE vs. FLEx.

    PubMed

    Alió, J L; El Bahrawy, M; Angelov, A; Ortiz, D; Yébana, P

    2017-05-01

    To investigate the influence of creating a flap on the postoperative optical quality of the cornea in terms of predicted corneal curvature and Seidel aberrations after 2 modalities of femtosecond assisted corneal lenticule extraction laser for the correction of myopia and myopic astigmatism: The flapless procedure small incision lenticular extraction (SMILE) and the flap-based femtosecond lenticular extraction (FLEx). The study is a prospective consecutive non-randomised comparative interventional case series including 64 eyes with myopic or myopic astigmatism refractive errors. Patients were divided into 2 groups matched for age, sex and myopia. One group underwent SMILE treatment and the other underwent FLEx treatment. Seidel aberrations root-mean-square values were obtained with a 10mm aperture using the ATLAS 9000 topographer before surgery and 3 months after surgery. The relationship between the post-surgical corneal radius and the predicted sculpted radius were analysed in each group. The mean percentage change in the curvature radius was -2.03% in the FLEx group and -1.77% in the SMILE group (P=.655). The higher correlation for the SMILE group demonstrates a better predictability after the surgery. As regards corneal aberrations, the FLEx treatment showed a greater increase of higher order aberrations than SMILE treatment (P=.04). The mean refractive change in corneal curvature, which is indirectly related to the biomechanical response of the corneal surface after the lenticule cut and extraction, was similar after both treatments. However, the flap based FLEx procedure showed a greater degradation of the corneal optical quality in terms of induction of higher order aberrations. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses.

    PubMed

    Marcos, Susana; Rosales, Patricia; Llorente, Lourdes; Jiménez-Alfaro, Ignacio

    2007-02-01

    To study the effect of cataract surgery through 3.2 mm superior incisions on corneal aberrations with 2 types of monofocal intraocular lenses (IOLs) with an aspherical design. Instituto de Optica, Consejo Superior de Investigaciones Científicas, and Fundación Jiménez Díaz, Madrid, Spain. Corneal topography of 43 eyes was obtained before and after small corneal incision cataract surgery. Twenty-two eyes had implantation of a Tecnis Z9000 silicone IOL (Advanced Medical Optics) and 21 had implantation of an AcrySof IQ SN60WF acrylic IOL (Alcon Research Labs) using the recommended injector for each IOL type. The intended incision size (3.2 mm) was similar in the 2 groups. Corneal aberrations were estimated using custom-developed algorithms (based on ray tracing) for 10.0 mm and 5.0 mm pupils. Comparisons between preoperative and postoperative measurements and across the groups were made for individual Zernike terms and root-mean-square (RMS) wavefront error. The RMS (excluding tilt and defocus) did not change in the AcrySof IQ group and increased significantly in the Tecnis group with the 10.0 mm and 5.0 mm pupil diameters. Spherical aberration and coma-like terms did not change significantly; however, vertical astigmatism, vertical trefoil, and vertical tetrafoil changed significantly with surgery with the 10.0 mm and 5.0 mm pupil diameters (P<.0005). The induced wave aberration pattern for 3rd- and higher-order aberrations consistently showed a superior lobe, resulting from a combination of positive vertical trefoil (Z(3)(-3)) and negative tetrafoil (Z(4)(4)). The mean vertical astigmatism increased by 2.47 microm +/- 1.49 (SD) and 1.74 +/- 1.44 microm, vertical trefoil increased by 1.81 +/- 1.19 microm and 1.20 +/- 1.34 microm, and tetrafoil increased by -1.10 +/- 0.78 microm and -0.89 +/- 0.68 microm in the Tecnis group and AcrySof IQ group, respectively. There were no significant differences between the corneal aberrations in the 2 postoperative groups

  9. Corneal Thickness in Highlanders.

    PubMed

    Patyal, Sagarika; Arora, Amit; Yadav, Arun; Sharma, Vijay K

    2017-03-01

    Patyal, Sagarika, Amit Arora, Arun Yadav, and Vijay K. Sharma. Corneal thickness in highlanders. High Alt Med Biol. 18:56-60, 2017. Corneal thickness is an important parameter with diagnostic and therapeutic implications. Various studies have highlighted increase in corneal thickness in lowlanders on ascending to high altitude. However, there are no studies in the published literature pertaining to corneal thickness of the highlanders who are inhabitants of such altitudes. Hence, study was carried out with objective to determine the corneal thickness of highlanders living at heights of more than 11,000 feet and compare it with corneal thickness of lowlanders. The highlander participants of the study consisted of inhabitants of Ladakh region of India at an altitude of 11,000 feet or more and lowlander participants consisted of inhabitants at an altitude of 1500 feet. A total of 254 highlanders and 212 lowlanders participated. A mean of 25 measurements of central corneal thickness (CCT) of every participant was obtained for each eye using ultrasonic pachymeter. The mean age of the participants was 41.8 (15.9) and 47.7 (17.7) years among lowlanders and highlanders, respectively. The highlanders had 11.95 μm lower mean CCT reading compared to lowlanders after adjusting for age and sex (p value <0.001). There was no statistically significant difference in mean CCT readings of right eye and left eye in either lowlanders or highlanders. Age also had a significant effect after adjustment for location and gender (p = 0.001). CCT decreased by 0.31 μm with every year increase in the age. Gender had no statistically significant effect. This study found statistically significant difference in CCT measurements between highlanders and lowlanders. The thinner corneas of highlanders may have a bearing on diagnosis and treatment of glaucoma, refractive surgery, contact lens fitting implantation of Intacs, and astigmatic keratectomy done on such patients. The study also

  10. Comparison of Astigmatic Correction after Femtosecond Lenticule Extraction and Small-Incision Lenticule Extraction for Myopic Astigmatism

    PubMed Central

    Kobashi, Hidenaga; Kamiya, Kazutaka; Ali, Mohamed A.; Igarashi, Akihito; Elewa, Mohamed Ehab M.; Shimizu, Kimiya

    2015-01-01

    Purpose To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and small-incision lenticule extraction (SMILE) in eyes with myopic astigmatism. Methods We examined 26 eyes of 26 patients undergoing FLEx and 26 eyes of 26 patients undergoing SMILE to correct myopic astigmatism (manifest astigmatism of 1 diopter (D) or more). Visual acuity, cylindrical refraction, the predictability of the astigmatic correction, and the astigmatic vector components using Alpin’s method, were compared between the two groups 3 months postoperatively. Results We found no statistically significant difference in manifest cylindrical refraction (p=0.74) or in the percentage of eyes within ± 0.50 D of their refraction (p=0.47) after the two surgical procedures. Moreover, no statistically significant difference was detected between the groups in astigmatic vector components, namely, surgically induced astigmatism (0.80), target induced astigmatism (p=0.87), astigmatic correction index (p=0.77), angle of error (p=0.24), difference vector (p=0.76), index of success (p=0.91), flattening effect (p=0.79), and flattening index (p=0.84). Conclusions Both FLEx and SMILE procedures are essentially equivalent in correcting myopic astigmatism using vector analysis, suggesting that the lifting or non-lifting of the flap does not significantly affect astigmatic outcomes after these surgical procedures. PMID:25849381

  11. Analysis of correlation between corneal topographical data and visual performance

    NASA Astrophysics Data System (ADS)

    Zhou, Chuanqing; Yu, Lei; Ren, Qiushi

    2007-02-01

    Purpose: To study correlation among corneal asphericity, higher-order aberrations and visual performance for eyes of virgin myopia and postoperative laser in situ keratomileusis (LASIK). Methods: There were 320 candidates 590 eyes for LASIK treatment included in this study. The mean preoperative spherical equivalence was -4.35+/-1.51D (-1.25 to -9.75), with astigmatism less than 2.5 D. Corneal topography maps and contrast sensitivity were measured and analyzed for every eye before and one year after LASIK for the analysis of corneal asphericity and wavefront aberrations. Results: Preoperatively, only 4th and 6th order aberration had significant correlation with corneal asphericity and apical radius of curvature (p<0.001). Postoperatively, all 3th to 6th order aberrations had statistically significant correlation with corneal asphericity (p<0.01), but only 4th and 6th order aberration had significant correlation with apical radius of curvature (p<0.05). The asymmetrical aberration like coma had significant correlation with vertical offset of pupil center (p<0.01). Preoperatively, corneal aberrations had no significant correlation with visual acuity and area under the log contrast sensitivity (AULCSF) (P>0.05). Postoperatively, corneal aberrations still didn't have significant correlation with visual acuity (P>0.05), but had significantly negative correlation with AULCSF (P<0.01). Corneal asphericity had no significant correlation with AULCSF before and after the treatment (P>0.05). Conclusions: Corneal aberrations had different correlation with corneal profile and visual performance for eyes of virgin myopia and postoperative LASIK, which may be due to changed corneal profile and limitation of metrics of corneal aberrations.

  12. Optical modeling of a corneal inlay in real eyes to increase depth of focus: optimum centration and residual defocus.

    PubMed

    Tabernero, Juan; Artal, Pablo

    2012-02-01

    To determine the optimum position to center a small-aperture corneal inlay and the effect of residual defocus in the surgical eye to maximize depth of focus. Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain. Cohort study. Personalized eye models were built using actual data (corneal topography, eye length, ocular aberrations, and eye alignment). A small aperture 1.6 mm in diameter was placed at the corneal plane in each model. The monochromatic and polychromatic Strehl ratios were calculated as a function of the pinhole position. Different residual defocus values were also incorporated into the models, and the through-focus Strehl ratios were calculated. Sixteen eye models were built. For most subjects, the optimum location of the aperture for distance vision was close to the corneal reflex position. For a given optimized centration of the aperture, the best compromise of depth of focus was obtained when the eyes had some residual myopic defocus (range -0.75 to -1.00 diopter [D]). Strehl ratio values were over 0.1 for far distance, which led to visual acuities better than 20/20. The depth of focus was 2.50 D with a mean near visual acuity of Jaeger 1 or better. In eyes with little astigmatism and aberrations, the optimum centration of the small aperture was near the corneal reflex position. To improve optical outcomes with the inlay, some small residual myopia and correction of corneal astigmatism might be required. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Astigmatism reduction clinical trial: a multicenter prospective evaluation of the predictability of arcuate keratotomy. Evaluation of surgical nomogram predictability. ARC-T Study Group.

    PubMed

    Price, F W; Grene, R B; Marks, R G; Gonzales, J S

    1995-03-01

    To determine the accuracy of the Lindstrom surgical nomogram for astigmatism. A prospective multicenter study. One hundred sixty eyes of 95 patients underwent astigmatic keratotomy in eight centers by nine surgeons. Inclusion criteria for the study included age of at least 18 years with 1 to 6 diopters (D) of naturally occurring corneal astigmatism and less than 1 D of lenticular astigmatism. A standardized astigmatic keratotomy surgical technique was performed on each eye. Surgical measurements were determined using the Lindstrom surgical nomogram for astigmatism. The Holladay, Cravy, Koch vector analysis method was used to determine the change in refractive cylinder results. Refractive changes also are presented without vector analysis merely using the absolute change in refractive cylinder and axis. Multiple regression analysis was used to develop a mathematical model determining the factors predictive of the change in refractive cylinder. The significant predictors for the amount of astigmatic correction achieved were, in order of decreasing importance, the following: number of incisions (R2 = 30%), incision length (R2 = 16%), age (R2 = 8%), and gender (R2 = 2%). Astigmatism is a two-dimensional measurement of both quantity and direction that is most appropriately analyzed with vector analysis. The original Lindstrom surgical nomogram for arcuate keratotomy used in this study is still quite useful although it tended to underpredict results for many patients, especially those having two incisional surgeries. Some older subjects having minimal surgery achieved greater correction than predicted by the original nomogram. The most important factors predictive of greater astigmatic keratotomy surgical effect are incision number, incision length, older age, and male gender.

  14. Effects of Induced Astigmatism.

    ERIC Educational Resources Information Center

    Schubert, Delwyn G.; Walton, Howard N.

    1968-01-01

    The relationship of astigmatism to reading and the possible detrimental effects it might have on reading were investigated. The greatest incidence of astigmatism was for the with-the-rule type ranging from .50 to 1.00 diopter. This type of astigmatism was induced in 35 seniors from the Los Angeles College of Optometry by placing cylindrical lenses…

  15. Microincision bimanual phacoemulsification and Thinoptx implantation through a 1.70 mm incision.

    PubMed

    Prakash, P; Kasaby, H E; Aggarwal, R K; Humfrey, S

    2007-02-01

    To prospectively assess the efficacy of bimanual phacoemulsification and implantation of Thinoptx, an injectable intraocular lens (IOL), inserted through 1.70 mm clear corneal incision. Department of Ophthalmology, Southend Hospital NHS Trust, UK. A total of 50 eyes of 49 randomly selected patients with cataracts had microincision clear corneal bimanual phacoemulsification (MICS) with implantation of Thinoptx IOL in the capsular bag. All patients underwent full preoperative assessment. Postoperative assessment was carried out at 3 and 6 weeks and at 15 months. In all 50 cases the IOL was inserted through 1.70 mm clear corneal incision. The mean best-corrected visual acuity was 0.02 (6/6-1) at 6 weeks and was 0.17 (6/10) at the final follow-up. The mean final surgically induced astigmatism at 6 weeks was 0.0106. Coloured haloes around artificial lights were perceived by 69.23% of patients at 6 weeks and by 61.29% at the final follow-up. One patient underwent IOL exchange for this. Posterior capsular opacification was noticed in 31.26% at 6 weeks and in 64.51% at 15 months. Anterior capsular opacification was noticed in 5.26% at 6 weeks and in 16.12% at 15 months. In one patient the IOL had to be exchanged because of tilt and displacement of the IOL due to anterior capsular phimosis. We conclude Thinoptx can be safely inserted through 1.70 mm incision used for bimanual phacoemulsification. Distance and near visual acuity achieved with this IOL is satisfactory. There is no significant change in keratometric astigmatism following this procedure. However, posterior capsular opacification rate was significantly higher with this IOL. Haloes around light sources were significant.

  16. Corneal donor tissue preparation for endothelial keratoplasty.

    PubMed

    Woodward, Maria A; Titus, Michael; Mavin, Kyle; Shtein, Roni M

    2012-06-12

    Over the past ten years, corneal transplantation surgical techniques have undergone revolutionary changes. Since its inception, traditional full thickness corneal transplantation has been the treatment to restore sight in those limited by corneal disease. Some disadvantages to this approach include a high degree of post-operative astigmatism, lack of predictable refractive outcome, and disturbance to the ocular surface. The development of Descemet's stripping endothelial keratoplasty (DSEK), transplanting only the posterior corneal stroma, Descemet's membrane, and endothelium, has dramatically changed treatment of corneal endothelial disease. DSEK is performed through a smaller incision; this technique avoids 'open sky' surgery with its risk of hemorrhage or expulsion, decreases the incidence of postoperative wound dehiscence, reduces unpredictable refractive outcomes, and may decrease the rate of transplant rejection. Initially, cornea donor posterior lamellar dissection for DSEK was performed manually resulting in variable graft thickness and damage to the delicate corneal endothelial tissue during tissue processing. Automated lamellar dissection (Descemet's stripping automated endothelial keratoplasty, DSAEK) was developed to address these issues. Automated dissection utilizes the same technology as LASIK corneal flap creation with a mechanical microkeratome blade that helps to create uniform and thin tissue grafts for DSAEK surgery with minimal corneal endothelial cell loss in tissue processing. Eye banks have been providing full thickness corneas for surgical transplantation for many years. In 2006, eye banks began to develop methodologies for supplying precut corneal tissue for endothelial keratoplasty. With the input of corneal surgeons, eye banks have developed thorough protocols to safely and effectively prepare posterior lamellar tissue for DSAEK surgery. This can be performed preoperatively at the eye bank. Research shows no significant difference in

  17. Comparison of astigmatic correction after femtosecond lenticule extraction and wavefront-guided LASIK for myopic astigmatism.

    PubMed

    Ali, Mohamed A; Kobashi, Hidenaga; Kamiya, Kazutaka; Igarashi, Akihito; Miyake, Toshiyuki; Elewa, Mohamed Ehab M; Komatsu, Mari; Shimizu, Kimiya

    2014-12-01

    To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and wavefront-guided LASIK in eyes with myopic astigmatism. Fifty-eight eyes of 41 patients undergoing FLEx and 49 eyes of 29 patients undergoing wavefront-guided LASIK to correct myopic astigmatism were examined. Visual acuity, cylindrical refraction, predictability of the astigmatic correction, and astigmatic vector components were compared between groups 6 months after surgery. There was no statistically significant difference in manifest cylindrical refraction (P = .08) or percentage of eyes within ± 0.50 diopter (D) of its refraction (P = .11) between the surgical procedures. The index of success in FLEx was statistically significantly better than that of wavefront-guided LASIK (P = .02), although there was no significant difference between the groups in other indices (eg, surgically induced astigmatism, target-induced astigmatism, astigmatic correction index, angle of error, difference vector, and flattening index). Subgroup analysis showed that FLEx had a better index of success (P = .02) and difference vector (P = .04) than wavefront-guided LASIK in the low cylinder subgroup; the angle of error in FLEx was significantly smaller than that of wavefront-guided LASIK in the moderate cylinder subgroup (P = .03). Both FLEx and wavefront-guided LASIK worked well for the correction of myopic astigmatism by the 6-month follow-up visit. Although FLEx had a better index of success than wavefront-guided LASIK when using vector analysis, it appears equivalent to wavefront-guided LASIK in terms of visual acuity and the correction of astigmatism. Copyright 2014, SLACK Incorporated.

  18. Correlation between the graft-host junction of penetrating keratoplasty by anterior segment-optical coherence tomography and the magnitude of postoperative astigmatism.

    PubMed

    Nassar, Ghada Azab; Arfeen, Shaimaa Abd El Salam

    2017-07-01

    This study aimed to evaluate the alignment pattern of the graft-host junction after penetrating keratoplasty (PK) by anterior segment-optical coherence tomography (AS-OCT) and to correlate this pattern with the magnitude of postoperative astigmatism. This retrospective observational study was carried out on forty patients who underwent PK from February 2013 to August 2014. AS-OCT was performed, and the graft-host junctions were classified into well-apposed junction, malapposed junction, and equally apposed junction. Mal-apposition is subdivided into gap and protrusion. The correlations between clinical characteristics, wound profiles from the AS-OCT, and the magnitude of postoperative astigmatism by Sirius camera (Costruzione Strumenti Oftalmici [CSO], Florence, Italy (CSO, Sirius), were analyzed. Graft-host junctions from forty patients were analyzed; 18 eyes had well-apposed junctions, ten eyes had malapposed junctions, and 12 had equally apposed junctions. The mean cylinder was -9.44 ± -4.00D in well-apposed group, -13.40 ± -5.01D in malapposed group, and -4.67 ± -0.94D in equally apposed group. Alignment pattern of the graft-host junction correlated significantly with the magnitude of astigmatism (P = 0.034). Preoperative corneal diseases did not have an effect on the magnitude of astigmatism (P = 0.123). The alignment pattern of the graft-host junction by AS-OCT can explain the postoperative astigmatism after PK where it correlates significantly with the magnitude of astigmatism.

  19. Outcomes of Phacoemulsification Using Different Size of Clear Corneal Incision in Eyes with Previous Radial Keratotomy.

    PubMed

    Zhang, Jing Shang; Liu, Xue; Wang, Jin Da; Xiong, Ying; Li, Jing; Li, Xiao Xia; Zhao, Jing; You, Qi Sheng; Huang, Yao; Tsai, Frank; Baum, Larry; Jhanji, Vishal; Wan, Xiu Hua

    2016-01-01

    To evaluate visual outcomes and complications after phacoemulsification in eyes with cataract and previous radial keratotomy (RK) cuts using different sizes of clear corneal incisions. The study was a retrospective study. Thirty eyes with cataract and previous RK underwent phacoemulsification and intraocular lens (IOL) implantation. Among them 7 eyes had 8 RK cuts, 13 eyes had 12 RK cuts, and 10 eyes had 16 RK cuts. Phacoemulsification and IOL implantation were performed through a 2.0-3.2 mm clear corneal incision by a single surgeon. In the 8 RK cuts group, 3.2 mm clear corneal incisions were used in 4 eyes, and 3.0 mm clear corneal incisions were used in 3 eyes. In the 12 RK cuts group, 3.2 mm clear corneal incisions were used in 6 eyes, and 2.2 mm clear corneal incisions were used in 7 eyes. In the 16 RK cuts group, 3.2 mm clear corneal incisions were used in 5 eyes, and 2.0 mm clear corneal incisions were used in 5 eyes. Patients were followed up 1 day, 1 week, 1 month, 3 months, 6 months, 1 year, 2 years, and 3 years postoperatively and were examined for the dehiscence of RK cuts during or after the surgery, post-operative best-corrected visual acuity (BCVA), corneal astigmatism, corneal endothelial cell density and complications. Successful phacoemulsification with IOL implantation was performed in all eyes. No wound dehiscence was noted in any eyes with 8 or 12 RK cuts. Wound dehiscence was noted in 2 eyes with 16 RK cuts. The dehiscence of RK cuts was closed successfully by injecting an air bubble with or without viscoelastic agent into the anterior chamber at the end of surgery. During the follow-up, the cuts were well apposed in all eyes, and no new dehiscence of RK cuts was noted. At the last follow-up, mean BCVA (0.2 ± 0.18 logMAR) was better than preoperative BCVA(0.45±0.19 logMAR) (P < 0.001). There was no significant difference between the long-term preoperative and postoperative mean corneal astigmatism (P = 0.3). However, there was a significant

  20. Effect of Fasting on Corneal Biomechanical and Structural Parameters.

    PubMed

    Sarici, Ahmet M; Yuksel Elgin, Cansu; Dikkaya, Funda

    2016-07-01

    To evaluate the effects of hunger and thirst on corneal biomechanical and structural parameters during Ramadan fasting. Corneal biomechanical properties and intraocular pressures of 29 eyes of 29 healthy subjects were evaluated by Reichert ocular response analyzer; and structural and anatomical properties of cornea and anterior eye chamber of same eyes were scanned with Oculus Pentacam anterior segment analyzer. Each eye has been evaluated at 8 am and 4 pm both during and 1 month after Ramadan. Changes of subjects' weight were calculated and their relationship with corneal biomechanical and structural parameters was assessed. Intraday changes in horizontal corneal astigmatism (p = 0.02), anterior chamber volume (p = 0.01), intraocular pressure associated with the Goldmann IOPg (p = 0.02) and corneal resistance factor (CRF) (p = 0.04) were significantly different when measured during the fasting period in Ramadan and 1 month thereafter. Moreover, when we compared 8 am measurements taken during and after Ramadan, we observed significant differences for anterior chamber volume (p = 0.04) and anterior chamber angle values (p = 0.03). Similarly, for 4 pm measurements, there were significant differences for IOPg (p = 0.01) and CRF values (p = 0.00). Fasting lasting for more than 12 h during Ramadan creates an important window of opportunity to investigate the response of anterior chamber of eye to hunger and thirst. The current study contributes to the existing literature on the effects of dietary habits and water intake on corneal and anterior chamber properties.

  1. Anisometropia of spherical equivalent and astigmatism among myopes: a 23-year follow-up study of prevalence and changes from childhood to adulthood.

    PubMed

    Pärssinen, Olavi; Kauppinen, Markku

    2017-08-01

    To study anisometropia of spherical equivalent and astigmatism from the onset of myopia at school age to adulthood. A total of 240 myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983-1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Examinations with subjective cyclopedic refraction were repeated 3 years later (follow-up 1) for 238 subjects and thereafter at the mean ages of 23.2 (follow-up 2) and 33.9 years (follow-up 3) for 178 and 134 subjects. After exclusions, the 102 subjects who attended all three follow-ups were included in the analyses. Corneal refractive power and astigmatism and anterior chamber depth was measured with Pentacam topography and axial length with IOL master at study end. Prevalence and changes in anisometropia of spherical equivalent (AnisoSE) and astigmatism (AnisoAST) and their relationships with refractive and axial measures were studied. Mean (±SD) of spherical equivalent (SE), AnisoSE and AnisoAST increased from baseline to follow-up end from -1.44 ± 0.57 D to -5.11 ± 2.23 D, from 0.28 ± 0.30 D to 0.68 ± 0.69 D and from 0.14 ± 0.18 D to 0.37 ± 0.36 D, respectively. Prevalence of AnioSE, ≥1 D, increased from 5% to 22.6% throughout follow-up. Higher AnisoSE was associated with SE in the less myopic eye at baseline and at follow-up 1, and with SE in the more myopic eye in follow-ups 2 and 3 in adulthood. At study end, AnisoSE was associated with the interocular difference in axial length (AL) (r = 0.612, p < 0.001) but not with the interocular difference in corneal refraction (CR) (r = -0.122, p = 0.266). In cases of low AnisoSE(≤1.00 D), the negative correlation between the real interocular differences (value of right eye minus value of left eye) in CR and AL (r = -0.427, p < 0.001) decreased the influence of the interocular difference in AL on AnisoSE, causing emmetropization in AnisoSE. The interocular difference in corneal

  2. [Astigmatism correction with Excimer laser].

    PubMed

    Gauthier, L

    2012-03-01

    Excimer laser is the best and the more used technique for Astigmatism correction. Lasik is generally preferred to PRK and must be the choice for hyperopic and mix astigmatisms. Myopic astigmatisms are the easier cases to treat: the length of the photoablation is placed on the flat meridian. Hyperopic and mix astigmatisms are more difficult to correct because they are more technically demanding and because the optical zone of the photoablation must be large. Flying spots lasers are the best for these cases. The most important point is to trace the photoablation very precisely on the astigmatism axis. The use of eye trackers with iris recognition or a preoperative marking of the reference axis avoid cyclotorsion or a wrong position of the head. Irregular astigmatism are better corrected with topoguided or wavefront guided photoablations. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  3. Combined Special Capsular Tension Ring and Toric IOL Implantation for Management of Astigmatism and High Axial Myopia with Cataracts.

    PubMed

    Zhao, Yang; Li, Jiaxin; Yang, Ke; Li, Xiao; Zhu, Siquan

    2018-01-01

    This study aimed to compare the effects of toric intraocular lens (IOL) implantation with a capsular tension ring and toric IOL implantation only in patients with axial myopic astigmatism who had undergone cataract surgery. Of 34 patients with axial myopia, 16 patients who had received IOL and capsular tension ring (CTR) implantation were included in the combined group and 18 patients who received toric IOL implantation only were included in the simple group. Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA) were evaluated by measuring subjective refraction, residual astigmatism, and the toric IOL axis six months post-surgery. At six months postoperatively, the UCVA for the combined and simple groups was 4.6 ± 0.1 and 4.5 ± 0.2, respectively, a statistically significant difference (t = 3.531, P<0.05). The toric IOL in all of the cases was located in the capsular sac, but there were more cases with IOL rotation (12 eyes) in the simple group than in the combined group (4 eyes). The rotation angles were 20°~30° (one eye), 10°~20° (four eyes), and <10° (seven eyes) compared with 2°~5° (four eyes). The residual astigmatism was -0.50 ± 0.25 D in the combined group, not a significant difference from the predicted residual astigmatism (-0.35 ± 0.13 D). There was a significant difference in the simple group (-1.25 ± 0.33 D) when the predicted residual astigmatism was compared (-0.37 ± 0.11 D) (t = -9.511, P < 0.01). In patients with axial myopic astigmatism, CTR can effectively increase the rotational stability of a toric IOL, achieving improvement in corneal astigmatism and visual acuity.

  4. Accelerated versus conventional corneal collagen cross-linking in patients with keratoconus: an intrapatient comparative study.

    PubMed

    Sadoughi, Mohammad Mehdi; Einollahi, Bahram; Baradaran-Rafii, Alireza; Roshandel, Danial; Hasani, Hamidreza; Nazeri, Mehrdad

    2018-02-01

    To compare the outcomes of the conventional and accelerated corneal collagen cross-linking (CXL) in patients with bilateral progressive keratoconus (KC). Fifteen consecutive patients with bilateral progressive KC were enrolled. In each patient, the fellow eyes were randomly assigned to the conventional CXL (3 mW/cm 2 for 30 min) or accelerated CXL (ACXL) (9 mW/cm 2 for 10 min) groups. Manifest refraction; uncorrected and corrected distant visual acuity; maximum and mean keratometry; corneal hysteresis and corneal resistance factor; endothelial cell density and morphology; central corneal thickness; and wavefront aberrations were measured before and 12 months after the CXL. Manifest refraction spherical equivalent and refractive cylinder improved significantly only in conventional group. Uncorrected and corrected distant visual acuity did not change significantly in either group. Also there was no significant change in the maximum and mean keratometry after 12 months. There was significant decrease in central corneal thickness in both groups which was more prominent in conventional group. Endothelial cell density reduced only in the conventional group which was not statistically significant (P = 0.147). CH, CRF, and wavefront aberrations did not change significantly in either group. We did not observe any significant difference in the changes of the variables between the two groups. Accelerated CXL with 9 mW/cm 2 irradiation for 10 min had similar refractive, visual, keratometric, and aberrometric results and less adverse effects on the corneal thickness and endothelial cells as compared with the conventional method after 12 months follow-up. However, randomized clinical trials with longer follow-ups and larger sample sizes are needed.

  5. Astigmatism induced by conventional spherical ablation after PRK and LASIK in myopia with astigmatism < 1.00 D.

    PubMed

    Christiansen, Steven M; Mifflin, Mark D; Edmonds, Jason N; Simpson, Rachel G; Moshirfar, Majid

    2012-01-01

    The purpose of this study was to evaluate surgically-induced astigmatism after spherical ablation in photorefractive keratectomy (PRK) and laser-assisted in situ keratomileusis (LASIK) for myopia with astigmatism < 1.00 D. The charts of patients undergoing spherical PRK or LASIK for the correction of myopia with minimal astigmatism of <1.00 D from 2002 to 2012 at the John A Moran Eye Center in Salt Lake City, UT, were retrospectively reviewed. Astigmatism was measured by manifest refraction. The final astigmatic refractive outcome at 6 months postoperatively was compared with the initial refraction by Alpins vector analysis. For PRK, average cylinder increased from 0.39 ± 0.25 (0.00-0.75) preoperatively to 0.55 ± 0.48 (0.00-1.75) postoperatively (P = 0.014), compared with an increase in LASIK eyes from 0.40 ± 0.27 (0.00-0.75) preoperatively to 0.52 ± 0.45 (0.00-2.00) postoperatively (P = 0.041). PRK eyes experienced an absolute value change in cylinder of 0.41 ± 0.32 (0.00-1.50) and LASIK eyes experienced a change of 0.41 ± 0.31 (0.00-1.50, P = 0.955). Mean surgically-induced astigmatism was 0.59 ± 0.35 (0.00-1.70) in PRK eyes, with an increase in surgically-induced astigmatism of 0.44 D for each additional 1.00 D of preoperative cylinder; in LASIK eyes, mean surgically-induced astigmatism was 0.55 ± 0.32 (0.00-1.80, P = 0.482), with an increase in surgically-induced astigmatism of 0.29 D for each 1.00 D of preoperative cylinder. Spherical ablation can induce substantial astigmatism even in eyes with less than one diopter of preoperative astigmatism in both PRK and LASIK. No significant difference in the magnitude of surgically-induced astigmatism was found between eyes treated with PRK and LASIK, although surgically-induced astigmatism was found to increase with greater levels of preoperative astigmatism in both PRK and LASIK.

  6. The Auckland Cataract Study: 2 year postoperative assessment of aspects of clinical, visual, corneal topographic and satisfaction outcomes

    PubMed Central

    Thompson, A M; Sachdev, N; Wong, T; Riley, A F; Grupcheva, C N; McGhee, C N

    2004-01-01

    Aim: To assess clinical, visual, computerised corneal topographic, and subjective satisfaction with visual acuity, in a cohort of subjects 2 years after phacoemulsification surgery in a public hospital in New Zealand. Methods: Prospective study of a representative sample of 97 subjects (20%) randomly selected from 480 subjects in the original Auckland Cataract Study (ACS) cohort. The clinical assessment protocol was identical to the ACS and included an extensive questionnaire to enable direct comparisons to be made between the two groups. Results: The study population was predominantly female (66%) with a mean age of 76.3 (SD 9.9) years. New systemic and ocular disease affected 18.4% and 10.3% of subjects respectively, and 10.3% required referral to either a general practitioner (2.1%) or ophthalmologist (8.2%). Mean best spectacle corrected visual acuity (BSCVA) was 0.2 (0.2) logMAR units (6/9 Snellen equivalent), with mean spherical equivalent −0.37 (1.01) dioptres (D) and astigmatism −1.07 (0.70) D 2 years postoperatively, compared to mean BSCVA 0.1 (0.2) logMAR units (6/7.5 Snellen equivalent), spherical equivalent −0.59 (1.07) D, and astigmatism −1.14 (0.77) D 4 weeks after surgery. 94.9% of subjects retained a BSCVA of 6/12 or better, irrespective of pre-existing ocular disease. The overall posterior capsule opacification (PCO) rate was 20.4% and this was visually insignificant in all but 3.1% of eyes that had already undergone Nd:YAG posterior capsulotomy. Orbscan II elevation technology demonstrated corneal stability 2 years after uncomplicated phacoemulsification. Although corneal astigmatism was eliminated in approximately half of the subjects 1 month postoperatively, astigmatism showed a tendency to regress towards the preoperative level with local corneal thickening at the site of incision 2 years after cataract surgery. Of fellow eyes, 61.2% had undergone cataract surgery. Overall, 75.3% of subjects were moderately to very satisfied with their

  7. Astigmatism following retinal detachment surgery.

    PubMed Central

    Goel, R; Crewdson, J; Chignell, A H

    1983-01-01

    Eighty-three patients on whom successful retinal detachment had been performed were studied to note astigmatic changes following surgery. In the majority of cases the errors following such surgery are of no great clinical importance. However, in some situations a high degree of astigmatism may be produced. This study showed that these sequelae are particularly likely after radial buckling procedures, and surgeons favouring these techniques should be aware that astigmatic errors can be induced. The astigmatic errors may persist for several years after surgery. PMID:6838807

  8. Astigmatism induced by conventional spherical ablation after PRK and LASIK in myopia with astigmatism < 1.00 D

    PubMed Central

    Christiansen, Steven M; Mifflin, Mark D; Edmonds, Jason N; Simpson, Rachel G; Moshirfar, Majid

    2012-01-01

    Background The purpose of this study was to evaluate surgically-induced astigmatism after spherical ablation in photorefractive keratectomy (PRK) and laser-assisted in situ keratomileusis (LASIK) for myopia with astigmatism < 1.00 D. Methods The charts of patients undergoing spherical PRK or LASIK for the correction of myopia with minimal astigmatism of <1.00 D from 2002 to 2012 at the John A Moran Eye Center in Salt Lake City, UT, were retrospectively reviewed. Astigmatism was measured by manifest refraction. The final astigmatic refractive outcome at 6 months postoperatively was compared with the initial refraction by Alpins vector analysis. Results For PRK, average cylinder increased from 0.39 ± 0.25 (0.00–0.75) preoperatively to 0.55 ± 0.48 (0.00–1.75) postoperatively (P = 0.014), compared with an increase in LASIK eyes from 0.40 ± 0.27 (0.00–0.75) preoperatively to 0.52 ± 0.45 (0.00–2.00) postoperatively (P = 0.041). PRK eyes experienced an absolute value change in cylinder of 0.41 ± 0.32 (0.00–1.50) and LASIK eyes experienced a change of 0.41 ± 0.31 (0.00–1.50, P = 0.955). Mean surgically-induced astigmatism was 0.59 ± 0.35 (0.00–1.70) in PRK eyes, with an increase in surgically-induced astigmatism of 0.44 D for each additional 1.00 D of preoperative cylinder; in LASIK eyes, mean surgically-induced astigmatism was 0.55 ± 0.32 (0.00–1.80, P = 0.482), with an increase in surgically-induced astigmatism of 0.29 D for each 1.00 D of preoperative cylinder. Conclusion Spherical ablation can induce substantial astigmatism even in eyes with less than one diopter of preoperative astigmatism in both PRK and LASIK. No significant difference in the magnitude of surgically-induced astigmatism was found between eyes treated with PRK and LASIK, although surgically-induced astigmatism was found to increase with greater levels of preoperative astigmatism in both PRK and LASIK. PMID:23277735

  9. Combined laser in-situ keratomileusis and accelerated corneal cross-linking: an update.

    PubMed

    Tomita, Minoru

    2016-07-01

    The purpose is to review the literature of combined laser in-situ keratomileusis (LASIK) and accelerated corneal collagen cross-linking (CXL) in context of its indications-contraindications, kerato-refractive, visual and safety outcomes, particularly with reference to preventing the development of post-LASIK ectasia. LASIK + accelerated CXL has been developed with the rationale that the addition of CXL after LASIK may strengthen the LASIK compromised corneal biomechanics and minimize the complications such as post-LASIK ectasia. Different clinical studies have documented the safety and efficacy of LASIK + accelerated CXL for the correction of myopia or hyperopia and in the patients with low predicted residual bed thickness. Available literature shows that refractive and keratometric outcomes of LASIK + accelerated CXL are comparable or better than LASIK alone. Less regression has been observed after LASIK + accelerated CXL compared with LASIK alone and no case of post-LASIK ectasia development has been reported among 673 eyes with the follow-up ranging from 3 months to 4.5 years. Future studies with large numbers of patients and longer postoperative follow-ups are needed to establish the efficacy of LASIK + accelerated CXL in preventing the development of post-LASIK ectasia.

  10. Clinical Outcomes after Keraring Implantation for Keratoconus Management in Patients Older Than 40 Years: A Retrospective, Interventional, Cohort Study.

    PubMed

    Gatzioufas, Zisis; Khine, Aye; Elalfy, Mohamed; Guber, Ivo; McLintock, Cameron; Sabatino, Francesco; Hamada, Samer; Lake, Damian

    2018-06-01

    Intracorneal ring segment implantation is an effective and safe method of visual improvement in patients with keratoconus. The aim of our study was to evaluate the long-term clinical outcomes after Keraring implantation for keratoconus in patients older than 40 years. Eleven eyes from 11 patients with keratoconus who underwent femtosecond laser-assisted Keraring implantation for keratoconus were included in this retrospective study. The uncorrected visual acuity (UCVA), corrected visual acuity, keratometric readings, central corneal thickness and thinnest corneal pachymetry were evaluated preoperatively and 6 months after the Keraring implantation. UCVA, BCVA and keratometric readings improved at 6 months postoperatively. Our data showed significant keratometric amelioration and visual improvement after Keraring implantation for keratoconus in patients older than 40 years at 6 months postoperatively.

  11. Outcomes of Corneal Cross-Linking Correlate With Cone-Specific Lysyl Oxidase Expression in Patients With Keratoconus.

    PubMed

    Shetty, Rohit; Rajiv Kumar, Nimisha; Pahuja, Natasha; Deshmukh, Rashmi; Vunnava, KrishnaPoojita; Abilash, Valsala Gopalakrishnan; Sinha Roy, Abhijit; Ghosh, Arkasubhra

    2018-03-01

    To evaluate the correlation of visual and keratometry outcomes after corneal cross-linking (CXL) in patients with keratoconus with cone epithelium-specific gene expression levels. Corneal epithelium was obtained from 35 eyes that underwent accelerated CXL (KXLII, 9 mW/cm for 10 min). Using corneal topography, epithelium over the cone and periphery was obtained separately from each subject. The ratio of gene expression for lysyl oxidase (LOX), matrix metalloproteinase 9 (MMP9), bone morphogenic protein 7, tissue inhibitor of metalloproteinase 1, collagen, type I, alpha 1, and collagen, type IV, alpha 1 (COL IVA1) from the cone and peripheral cornea was correlated with the outcome of cross-linking surgery. Patients were assessed for visual acuity, keratometry, refraction, and corneal densitometry before and 6 months after surgery. Based on the change in corneal flattening indicated by ΔKmax, the outcomes were classified as a higher response or lower response. Reduction in keratometric indices correlated with improved spherical equivalent after CXL. Preoperative levels of cone-specific LOX expression in cases with a higher response were significant (P = 0.001). COL IVA1, bone morphogenic protein 7, and tissue inhibitor of metalloproteinase 1 gene expressions were reduced in the cones of the subjects with a lower response. MMP9 levels were relatively lower in cases with a higher response compared with those with a lower response. Our study demonstrates that preoperative levels of molecular factors such as LOX, MMP9, and COL IVA1 aid in understanding CXL outcomes at the tissue level.

  12. Calculation of laser pulse distribution maps for corneal reshaping with a scanning beam

    NASA Astrophysics Data System (ADS)

    Manns, Fabrice; Shen, Jin-Hui; Soederberg, Per G.; Matsui, Takaaki; Parel, Jean-Marie A.

    1995-05-01

    A method for calculating pulse distribution maps for scanning laser corneal surgery is presented. The accuracy, the smoothness of the corneal shape, and the duration of surgery were evaluated for corrections of myopia by using computer simulations. The accuracy and the number of pulses were computed as a function of the beam diameter, the diameter of the treatment zone, and the amount of attempted flattening. The ablation is smooth when the spot overlap is 80% or more. The accuracy does not depend on the beam diameter or on the diameter of the ablation zone when the ablation zone is larger than 5 mm. With an overlap of 80% and an ablation zone larger than 5 mm, the error is 5% of the attempted flattening, and 610 pulses are needed per Diopter of correction with a beam diameter of 1 mm. Pulse maps for the correction of astigmatism were computed and evaluated. The simulations show that with 60% overlap, a beam diameter of 1 mm, and a 5 mm treatment zone, 6 D of astigmatism can be corrected with an accuracy better than 1.8 D. This study shows that smooth and accurate ablations can be produced with a scanning spot.

  13. Amblyopia in Astigmatic Children: Patterns of Deficits

    PubMed Central

    Harvey, Erin M.; Dobson, Velma; Miller, Joseph M.; Clifford-Donaldson, Candice E.

    2007-01-01

    Neural changes that result from disruption of normal visual experience during development are termed amblyopia. To characterize visual deficits specific to astigmatism-related amblyopia, we compared best-corrected visual performance in 330 astigmatic and 475 non-astigmatic kindergarten through 6th grade children. Astigmatism was associated with deficits in letter, grating and vernier acuity, high and middle spatial frequency contrast sensitivity, and stereoacuity. Although grating acuity, vernier acuity, and contrast sensitivity were reduced across stimulus orientation, astigmats demonstrated orientation-dependent deficits (meridional amblyopia) only for grating acuity. Astigmatic children are at risk for deficits across a range of visual functions. PMID:17184807

  14. Adaptive cornea modeling from keratometric data.

    PubMed

    Martínez-Finkelshtein, Andrei; López, Darío Ramos; Castro, Gracia M; Alió, Jorge L

    2011-07-01

    To introduce an iterative, multiscale procedure that allows for better reconstruction of the shape of the anterior surface of the cornea from altimetric data collected by a corneal topographer. The report describes, first, an adaptive, multiscale mathematical algorithm for the parsimonious fit of the corneal surface data that adapts the number of functions used in the reconstruction to the conditions of each cornea. The method also implements a dynamic selection of the parameters and the management of noise. Then, several numerical experiments are performed, comparing it with the results obtained by the standard Zernike-based procedure. The numerical experiments showed that the algorithm exhibits steady exponential error decay, independent of the level of aberration of the cornea. The complexity of each anisotropic Gaussian-basis function in the functional representation is the same, but the parameters vary to fit the current scale. This scale is determined only by the residual errors and not by the number of the iteration. Finally, the position and clustering of the centers, as well as the size of the shape parameters, provides additional spatial information about the regions of higher irregularity. The methodology can be used for the real-time reconstruction of both altimetric data and corneal power maps from the data collected by keratoscopes, such as the Placido ring-based topographers, that will be decisive in early detection of corneal diseases such as keratoconus.

  15. Induced Higher-order aberrations after Laser In Situ Keratomileusis (LASIK) Performed with Wavefront-Guided IntraLase Femtosecond Laser in moderate to high Astigmatism.

    PubMed

    Al-Zeraid, Ferial M; Osuagwu, Uchechukwu L

    2016-03-22

    Wavefront-guided Laser-assisted in situ keratomileusis (LASIK) is a widespread and effective surgical treatment for myopia and astigmatic correction but whether it induces higher-order aberrations remains controversial. The study was designed to evaluate the changes in higher-order aberrations after wavefront-guided ablation with IntraLase femtosecond laser in moderate to high astigmatism. Twenty-three eyes of 15 patients with moderate to high astigmatism (mean cylinder, -3.22 ± 0.59 dioptres) aged between 19 and 35 years (mean age, 25.6 ± 4.9 years) were included in this prospective study. Subjects with cylinder ≥ 1.5 and ≤2.75 D were classified as moderate astigmatism while high astigmatism was ≥3.00 D. All patients underwent a femtosecond laser-enabled (150-kHz IntraLase iFS; Abbott Medical Optics Inc) wavefront-guided ablation. Uncorrected (UDVA), corrected (CDVA) distance visual acuity in logMAR, keratometry, central corneal thickness (CCT) and higher-order aberrations (HOAs) over a 6 mm pupil, were assessed before and 6 months, postoperatively. The relationship between postoperative change in HOA and preoperative mean spherical equivalent refraction, mean astigmatism, and postoperative CCT were tested. At the last follow-up, the mean UDVA was increased (P < 0.0001) but CDVA remained unchanged (P = 0.48) and no eyes lost ≥2 lines of CDVA. Mean spherical equivalent refraction was reduced (P < 0.0001) and was within ±0.50 D range in 61% of eyes. The average corneal curvature was flatter by 4 D and CCT was reduced by 83 μm (P < 0.0001, for all), postoperatively. Coma aberrations remained unchanged (P = 0.07) while the change in trefoil (P = 0.047) postoperatively, was not clinically significant. The 4th order HOAs (spherical aberration and secondary astigmatism) and the HOA root mean square (RMS) increased from -0.18 ± 0.07 μm, 0.04 ± 0.03 μm and 0.47 ± 0.11 μm, preoperatively, to 0.33 ± 0

  16. Astigmatism in reflector antennas.

    NASA Technical Reports Server (NTRS)

    Cogdell, J. R.; Davis, J. H.

    1973-01-01

    Astigmatic phase error in large parabolic reflector antennas is discussed. A procedure for focusing an antenna and diagnosing the presence and degree of astigmatism is described. Theoretical analysis is conducted to determine the nature of this error in such antennas.

  17. Reading Fluency in School-Age Children with Bilateral Astigmatism

    PubMed Central

    Harvey, Erin M.; Miller, Joseph M.; Twelker, J. Daniel; Davis, Amy L.

    2015-01-01

    Purpose To compare oral reading fluency (ORF) in students with no/low astigmatism and moderate/high astigmatism and to assess the impact of spectacle correction on ORF in moderate and high astigmats. Methods Subjects were 3rd–8th grade students from a highly astigmatic population. Refractive error was determined through subjectively refined cycloplegic autorefraction. Data from students with ocular abnormalities, anisometropia, symptomatic binocular vision disorders, or refractive error that did not meet study criteria (no/low (cyl < 1.00 both eyes, no significant myopia/hyperopia), moderate (cyl ≥ 1.00 D both eyes, mean ≥ 1.00 D and < 3.00 D), or high astigmatism group (cyl ≥ 1.00 D both eyes, mean ≥ 3.00 D)) were excluded. ORF was tested with a modified version of the DIBELS Next test of ORF. No/low astigmats were tested without spectacles; astigmats were tested with and without spectacles. Mean ORF was compared in no/low astigmats and astigmats (with and without correction). Improvement in ORF with spectacles was compared for moderate and high astigmats. Results The sample included 130 no/low, 67 moderate, and 76 high astigmats. ORF was lower in uncorrected astigmats than in no/low astigmats (p=0.011). ORF did not significantly differ in no/low astigmats and corrected astigmats (p=0.10). ORF significantly improved with spectacle correction in high astigmats (p=0.001, mean improvement 6.55 words per minute (WPM)), but not in moderate astigmats (p=0.193, mean improvement 1.87 WPM). Effects of spectacle wear were observed in students who read smaller text stimuli (older grades). Conclusions ORF is significantly reduced in students with bilateral astigmatism (≥ 1.00D) when uncorrected, but not when best-corrected, compared to their non-astigmatic peers. Improvement in ORF with spectacle correction is seen in high astigmats, but not in moderate astigmats. These data support the recommendation for full-time spectacle wear in astigmatic students

  18. Reading Fluency in School-Aged Children with Bilateral Astigmatism.

    PubMed

    Harvey, Erin M; Miller, Joseph M; Twelker, J Daniel; Davis, Amy L

    2016-02-01

    To compare oral reading fluency (ORF) in students with no/low astigmatism and moderate/high astigmatism and to assess the impact of spectacle correction on ORF in moderate and high astigmats. Subjects were third- to eighth-grade students from a highly astigmatic population. Refractive error was determined through subjectively refined cycloplegic autorefraction. Data from students with ocular abnormalities, anisometropia, symptomatic binocular vision disorders, or refractive error that did not meet study criteria (no/low [cylinder < 1.00 both eyes, no significant myopia/hyperopia], moderate [cylinder ≥ 1.00 D both eyes, mean ≥ 1.00 D and < 3.00 D], or high astigmatism group [cylinder ≥ 1.00 D both eyes, mean ≥ 3.00 D]) were excluded. Oral reading fluency was tested with a modified version of the Dynamic Indicators of Basic Early Literacy Skills (DIBELS) Next test of ORF. No/low astigmats were tested without spectacles; astigmats were tested with and without spectacles. Mean ORF was compared in no/low astigmats and astigmats (with and without correction). Improvement in ORF with spectacles was compared between moderate and high astigmats. The sample included 130 no/low, 67 moderate, and 76 high astigmats. ORF was lower in uncorrected astigmats than in no/low astigmats (p = 0.011). ORF did not significantly differ in no/low astigmats and corrected astigmats (p = 0.10). ORF significantly improved with spectacle correction in high astigmats (p = 0.001; mean improvement, 6.55 words per minute) but not in moderate astigmats (p = 0.193; mean improvement, 1.87 words per minute). Effects of spectacle wear were observed in students who read smaller text stimuli (older grades). ORF is significantly reduced in students with bilateral astigmatism (≥1.00D) when uncorrected but not when best-corrected compared with their nonastigmatic peers. Improvement in ORF with spectacle correction is seen in high astigmats but not in moderate astigmats. These data support the

  19. Tubular astigmatism-tunable fluidic lens.

    PubMed

    Kopp, Daniel; Zappe, Hans

    2016-06-15

    We demonstrate a new means to fabricate three-dimensional liquid lenses which may be tuned in focal length and astigmatism. Using actuation by electrowetting-on-dielectrics, astigmatism in arbitrary directions may be tuned independently, with almost no cross talk between orthogonal orientations. The lens is based on electrodes structured on planar polyimide foils and subsequently rolled, enabling high-resolution patterning of complex electrodes along the azimuthal and radial directions of the lens. Based on a design established through fluidic and optical simulations, the astigmatism tuning is experimentally verified by a change of the corresponding Zernike coefficients measured using a Shack-Hartmann wavefront sensor. It was seen that the back focal length can be tuned by 5 mm and 0° and 45° astigmatism by 3 μm through application of voltages in the range of 50  Vrms. It was observed that the cross talk with other aberrations is very low, suggesting a novel means for astigmatism control in imaging systems.

  20. Rapidly progressive idiopathic lenticular astigmatism.

    PubMed

    Tint, Naing L; Jayaswal, Rakesh; Masood, Imran; Maharajan, V Senthil

    2007-02-01

    A myopic 43-year-old woman with early nuclear sclerotic cataract developed more than 11.0 diopters (D) of astigmatism over a 6-month period. This was found to be lenticular in origin. Phacoemulsification with intraocular lens implantation was performed, resulting in residual astigmatism of 0.75 D. To our knowledge, this is the first case of rapidly progressive lenticular astigmatism in an otherwise healthy eye with early nuclear sclerotic cataract.

  1. Corneal higher-order aberrations and higher-order Strehl ratio after aberration-free ablation profile to treat compound myopic astigmatism.

    PubMed

    Brenner, Luis F

    2015-12-01

    To evaluate the changes in corneal higher-order aberrations (HOAs) and their impact on corneal higher-order Strehl ratio after aberration-free ablation profile. Verter Institute, H. Olhos, São Paulo, Brazil. Prospective interventional study. Eyes that had aberration-free myopic ablation were divided into 3 groups, based on the spherical equivalent (SE). The corneal HOAs and higher-order Strehl ratios were calculated before surgery and 3 months after surgery. The postoperative uncorrected-distance visual acuity, corrected-distance visual acuity, and SE did not present statistical differences among groups (88 eyes, P > .05). For a 6 mm pupil, the corneal HOA showed a mean increase of 0.17 μm (range 0.39 to 0.56 μm) (P < .001) and the corneal higher-order Strehl ratio presented a reduction of 0.03 (from 0.25 to 0.22) (P = .001). The following consistent linear predictive model was obtained: corneal HOA induction = 1.474 - 0.032 × SE - 0.225 × OZ, where OZ is the optical zone (R(2) = 0.49, adjusted R(2) = 0.48, P < .001). The corneal HOAs and the higher-order Strehl ratios deteriorated after moderate and high myopic ablations. The worsening in corneal aberrations and optical quality were related to the magnitude of the intended correction and did not affect high-contrast visual performance. The OZ was the only modifiable parameter capable to restrain the optical quality loss. The author has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Central Corneal Thickness and its Relationship to Intra-Ocular and Epidmiological Determinants.

    PubMed

    Tayyab, Ali; Masrur, Amena; Afzal, Farooq; Iqbal, Fyza; Naseem, Kamran

    2016-06-01

    To measure central corneal thickness in Pakistani population and determine its relationship to intra-ocular pressure, age, gender and ethnicity. Cross-sectional observation study. Pakistan Institute of Medical Sciences, Islamabad, Pakistan, between December 2013 and February 2015. The right eyes of 1000 cases (496 males and 504 females) were recruited for this study. Inclusion criteria were Pashtun or Punjabi ethnicity, intra-ocular pressure < 22 mmHg, gonioscopically open angles, cup-disk-ratio < 0.5, and age matched normal visual fields. Cases with prior ocular surgery, contact lens use, corneal pathologies, myopia or hypermetropia > ±3.0 diopters, astigmatism of > ±1.0 diopters were excluded. Central corneal thickness was measured using a TopCon non-contact specular microscope. Intra-ocular pressure was measured using Goldmann applanation tonometer. Frequency distribution, test of significance, and regression analysis was carried out using Statistical Package for Social Sciences version 20.0. Mean age was 47.31 ±11.78 years. Ethnic composition was 51.6% (n=516) Pashtun and 48.4% (n=484) Punjabi. The mean central corneal thickness was 503.96 (±12.47) µm, while the mean intra-ocular pressure was 15.61 (±2.68) mmHg. Regression analysis showed a significant association between central corneal thickness and intra-ocular pressure (p=0.00) and age (p=0.00). A±100 µchange in central corneal thickness was associated with change in IOPof ±3.30 mmHg, whereas central corneal thickness decreased by 0.12 µm per year. No significant association could be established between central corneal thickness and ethnicity (p=0.19). Central corneal thickness of the studied races was comparable to non-Caucasians which affects intra-ocular pressure measurements, and decreases with increasing age. No relationship was observed between central corneal thickness and ethnicity or gender.

  3. Simulation of the impact of refractive surgery ablative laser pulses with a flying-spot laser beam on intrasurgery corneal temperature.

    PubMed

    Shraiki, Mario; Arba-Mosquera, Samuel

    2011-06-01

    To evaluate ablation algorithms and temperature changes in laser refractive surgery. The model (virtual laser system [VLS]) simulates different physical effects of an entire surgical process, simulating the shot-by-shot ablation process based on a modeled beam profile. The model is comprehensive and directly considers applied correction; corneal geometry, including astigmatism; laser beam characteristics; and ablative spot properties. Pulse lists collected from actual treatments were used to simulate the temperature increase during the ablation process. Ablation efficiency reduction in the periphery resulted in a lower peripheral temperature increase. Steep corneas had lesser temperature increases than flat ones. The maximum rise in temperature depends on the spatial density of the ablation pulses. For the same number of ablative pulses, myopic corrections showed the highest temperature increase, followed by myopic astigmatism, mixed astigmatism, phototherapeutic keratectomy (PTK), hyperopic astigmatism, and hyperopic treatments. The proposed model can be used, at relatively low cost, for calibration, verification, and validation of the laser systems used for ablation processes and would directly improve the quality of the results.

  4. Manual limbal markings versus iris-registration software for correction of myopic astigmatism by laser in situ keratomileusis.

    PubMed

    Shen, Elizabeth P; Chen, Wei-Li; Hu, Fung-Rong

    2010-03-01

    To compare the efficacy and safety of manual limbal markings and wavefront-guided treatment with iris-registration software in laser in situ keratomileusis (LASIK) for myopic astigmatism. National Taiwan University Hospital, Taipei, Taiwan. Eyes with myopic astigmatism had LASIK with a Technolas 217z laser. Eyes in the limbal-marking group had conventional LASIK (PlanoScan or Zyoptix tissue-saving algorithm) with manual cyclotorsional-error adjustments according to 2 limbal marks. Eyes in the iris-registration group had wavefront-guided ablation (Zyoptix) in which cyclotorsional errors were automatically detected and adjusted. Refraction, corneal topography, and visual acuity data were compared between groups. Vector analysis was by the Alpins method. The mean preoperative spherical equivalent (SE) was -6.64 diopters (D) +/- 1.99 (SD) in the limbal-marking group and -6.72 +/- 1.86 D in the iris-registration group (P = .92). At 6 months, the mean SE was -0.42 +/- 0.63 D and -0.47 +/- 0.62 D, respectively (P = .08). There was no statistically significant difference between groups in the astigmatism correction, success, or flattening index values using 6-month postoperative refractive data. The angle of error was within +/-10 degrees in 73% of eyes in the limbal-marking group and 75% of eyes in the iris-registration group. Manual limbal markings and iris-registration software were equally effective and safe in LASIK for myopic astigmatism, showing that checking cyclotorsion by manual limbal markings is a safe alternative when automated systems are not available. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Corneal Aberrations in Former Preterm Infants: Results From The Wiesbaden Prematurity Study.

    PubMed

    Fieß, Achim; Schuster, Alexander K; Kölb-Keerl, Ruth; Knuf, Markus; Kirchhof, Bernd; Muether, Philipp S; Bauer, Jacqueline

    2017-12-01

    To compare corneal aberrations in former preterm infants to that of full-term infants. A prospective cross-sectional study was carried out measuring the corneal shape with Scheimpflug imaging in former preterm infants of gestational age (GA) ≤32 weeks and full-term infants with GA ≥37 weeks now being aged between 4 to 10 years. The main outcome measures were corneal aberrations including astigmatism (Zernike: Z2-2; Z22), coma (Z3-1; Z31), trefoil (Z3-3; Z33), spherical aberration (Z40) and root-mean square of higher-order aberrations (RMS HOA). Multivariable analysis was performed to assess independent associations of gestational age groups and of retinopathy of prematurity (ROP) occurrence with corneal aberrations adjusting for sex and age at examination. A total of 259 former full-term and 226 preterm infants with a mean age of 7.2 ± 2.0 years were included in this study. Statistical analysis revealed an association of extreme prematurity (GA ≤28 weeks) with higher-order and lower-order aberrations of the total cornea. Vertical coma was higher in extreme prematurity (P < 0.001), due to the shape of the anterior corneal surface, while there was no association with trefoil and spherical aberration. ROP was not associated with higher-order aberrations when adjusted for gestational age group. This study demonstrated that specific corneal aberrations were associated with extreme prematurity rather than with ROP occurrence.

  6. Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for mixed astigmatism refractive surgery.

    PubMed

    Stanca, Horia Tudor; Munteanu, Mihnea; Jianu, Dragoş Cătălin; Motoc, Andrei Gheorghe Marius; Jecan, Cristian Radu; Tăbăcaru, Bogdana; Stanca, Simona; Preda, Maria Alexandra

    2018-01-01

    To evaluate the predictability, efficacy and safety of Femtosecond-laser-assisted in situ keratomileusis (LASIK) procedure for mixed astigmatism. We prospectively evaluated for 12 months 74 eyes (52 patients) with mixed astigmatism that underwent Femtosecond-LASIK treatment. The preoperative mean refractive sphere value was +1.879±1.313 diopters (D) and the mean refractive cylinder value was -4.169±1.091 D. The anterior corneal flap was cut using the VisuMax® femtosecond laser and then the stromal ablation was done using the MEL® 80 excimer laser. Mean age was 30.22±6.421 years with 61.53% female patients. Postoperative spherical equivalent at 12 months was within ±0.5D of emmetropia in 75.8% of eyes and within ±1D in 97.3% of eyes. Postoperative uncorrected distance visual acuity was equivalent to or better than the preoperative corrected distance visual acuity in 91.9% of eyes. Compared to the preoperative corrected distance visual acuity (CDVA), 8.1% of eyes gained one line, 2.7% gained two lines and 2.7% gained three lines of visual acuity. Femtosecond-LASIK using the VisuMax®-MEL® 80 platform appears to have safe, effective and predictable results in mixed astigmatic eyes. The results are impressive for high refractive error treatment and for improvement of both uncorrected and corrected distance visual acuity.

  7. Lenticular astigmatism after penetrating eye injury.

    PubMed

    Rumelt, S; Jager, G; Rehany, U

    1996-09-01

    Lenticular astigmatism of 5.00 diopters developed after penetrating injury in the eye of a 16-year-old boy. Full visual acuity, refraction, and crystalline lens clarity remained stable for more than 2 years. The high astigmatism, in conjunction with a spherical cornea and posterior lens capsule striae, indicates the lenticular origin of the astigmatism.

  8. Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis.

    PubMed

    Fukuda, Shinichi; Beheregaray, Simone; Hoshi, Sujin; Yamanari, Masahiro; Lim, Yiheng; Hiraoka, Takahiro; Yasuno, Yoshiaki; Oshika, Tetsuro

    2013-12-01

    To evaluate the ability of parameters measured by three-dimensional (3D) corneal and anterior segment optical coherence tomography (CAS-OCT) and a rotating Scheimpflug camera combined with a Placido topography system (Scheimpflug camera with topography) to discriminate between normal eyes and forme fruste keratoconus. Forty-eight eyes of 48 patients with keratoconus, 25 eyes of 25 patients with forme fruste keratoconus and 128 eyes of 128 normal subjects were evaluated. Anterior and posterior keratometric parameters (steep K, flat K, average K), elevation, topographic parameters, regular and irregular astigmatism (spherical, asymmetry, regular and higher-order astigmatism) and five pachymetric parameters (minimum, minimum-median, inferior-superior, inferotemporal-superonasal, vertical thinnest location of the cornea) were measured using 3D CAS-OCT and a Scheimpflug camera with topography. The area under the receiver operating curve (AUROC) was calculated to assess the discrimination ability. Compatibility and repeatability of both devices were evaluated. Posterior surface elevation showed higher AUROC values in discrimination analysis of forme fruste keratoconus using both devices. Both instruments showed significant linear correlations (p<0.05, Pearson's correlation coefficient) and good repeatability (ICCs: 0.885-0.999) for normal and forme fruste keratoconus. Posterior elevation was the best discrimination parameter for forme fruste keratoconus. Both instruments presented good correlation and repeatability for this condition.

  9. Astigmatism

    MedlinePlus

    ... retina, at the back of your eye. A refractive error If either your cornea or lens is egg ... too close to the television or squinting. Other refractive errors Astigmatism may occur in combination with other refractive ...

  10. Corneal Optical Quality Following Sub 1.8 mm Micro-Incision Cataract Surgery vs. 2.2 mm Mini-Incision Coaxial Phacoemulsification

    PubMed Central

    Alió, Jorge L.; Elkady, Bassam; Ortiz, Dolores

    2010-01-01

    Purpose: To study and compare the effects of the micro-incision cataract surgery (MICS-sub 1.8 mm) and miniincision coaxial phacoemulsification (2.2 mm) on the optical quality of the cornea characterized in terms of corneal aberrations. Materials and Methods: Fifty eyes underwent MICS and 50 mini-incision phacoemulsification, by the same surgeon. Both types of cataract surgery were performed using low ultrasound power and through a clear corneal incision, placed on the steepest corneal meridian ranging from 1.6 to 1.8 in MICS (Group I) and from 2.12 to 2.3 mm in mini-incision coaxial phacoemulsification (Group II). Seidel and Zernike aberration coefficients and RMS values were obtained for a 6-mm pupil preoperatively and one month after surgery. Results: The corneal astigmatism did not show statistically significant changes in either of the two groups: (MICS: –0.73 ± 0.63, –0.65 ± 0.53 D, P = 0.25), (mini-incision phacoemulsification; –1.21 ± 1.52, –1.00 ± 1.19 D, P = 0.12). The total RMS remained unchanged after MICS (1.77 ± 1.7, 1.65 ± 1.3 μm, P = 0.18) and mini-incision phacoemulsification (2.00 ± 1.87, 2.09 ± 1.8 μm, P = 0.41). Statistically significant changes were found for coma (P = 0.004) and higher-order aberrations (P < 0.001), showing MICS significantly less changes in cornea. Conclusions: Both MICS and mini-incision phacoemulsification do not degrade the optical quality of the cornea. Both surgeries do not induce a modification of the corneal astigmatism, even in the axis. It seems that 2 mm is the limit around which no optical changes are induced by cataract surgery in the human cornea. PMID:20543945

  11. Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism.

    PubMed

    Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina

    2017-10-01

    To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 20/32 with +8.00/-4.50×30° for the right eye (RE) and 20/25 with +7.75/-2.25×120° for the left eye (LE). After CScL fitting, visual acuity was improved to 20/20 and 20/16 for the RE and LE, respectively. The patient wore these contact lenses an average of 13h a day. The total high order aberrations decreased by approximately 79% in the RE (2.37-0.50μm) and 47% in the LE (1.04-0.55μm) after CScL fitting. Visual quality and wearing time were maintained after 1year wearing CScL. In addition, no adverse ocular effects were found during this period. The present case report describes how the patient had CScL fitted successfully for management of keratoconus with high hyperopia and astigmatism. They provided optimal visual quality, along with prolonged use times and no adverse effects to the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Corneal Power Distribution and Functional Optical Zone Following Small Incision Lenticule Extraction for Myopia.

    PubMed

    Qian, Yishan; Huang, Jia; Zhou, Xingtao; Hanna, Rewais Benjamin

    2015-08-01

    To evaluate corneal power distribution using the ray tracing method (corneal power) in eyes undergoing small incision lenticule extraction (SMILE) surgery and compare the functional optical zone with two lenticular sizes. This retrospective study evaluated 128 patients who underwent SMILE for the correction of myopia and astigmatism with a lenticular diameter of 6.5 mm (the 6.5-mm group) and 6.2 mm (the 6.2-mm group). The data include refraction, correction, and corneal power obtained via a Scheimpflug camera from the pupil center to 8 mm. The surgically induced changes in corneal power (Δcorneal power) were compared to correction and Δrefraction. The functional optical zone was defined as the largest ring diameter when the difference between the ring power and the pupil center power was 1.50 diopters or less. The functional optical zone was compared between two lenticular diameter groups. Corneal power distribution was measured by the ray tracing method. In the 6.5-mm group (n=100), Δcorneal power at 5 mm showed the smallest difference from Δrefraction and Δcorneal power at 0 mm exhibited the smallest difference from correction. In the 6.2-mm group (n=28), Δcorneal power at 2 mm displayed the lowest dissimilarity from Δrefraction and Δcorneal power at 4 mm demonstrated the lowest dissimilarity from correction. There was no significant difference between the mean postoperative functional optical zones in either group when their spherical equivalents were matched. Total corneal refactive power can be used in the evaluation of surgically induced changes following SMILE. A lenticular diameter of 6.2 mm should be recommended for patients with high myopia because there is no functional difference in the optical zone. Copyright 2015, SLACK Incorporated.

  13. Evaluation of internal refraction with the optical path difference scan.

    PubMed

    Muftuoglu, Orkun; Erdem, Uzeyir

    2008-01-01

    To evaluate internal refraction and its relation to other optical properties of the eye across a large range of refractive errors, which can provide useful information for the assessment and design of intraocular lenses and corneal ablation patterns. Cohort study. Three hundred ninety-four eyes of 197 healthy subjects with a mean age of 27+/-7 years (range, 18-42). All eyes underwent optical path difference scans to evaluate corneal topography, whole and internal ocular refraction (determined by the subtraction of corneal refraction from whole ocular refraction), and total and higher-order aberrations (HOAs) were assessed. After the conversion of any spherocylindrical refractive errors to vectorial data (sphere equivalent, blurring strength; cylinder, J(0) [power of Jackson cross cylinder at 90 degrees and 180 degrees] and J45 [power of Jackson cross cylinder at 45 degrees and 135 degrees]), the distribution of internal refraction among refraction groups (high myopes, low to moderate myopes, hyperopes, mixed astigmats, and emmetropes) and relationships between internal refraction, corneal refraction, and wavefront aberrations were analyzed. The compensation relation and its rate between corneal and internal astigmatism was assessed by the compensation factor (CF). Whole ocular power and astigmatism, corneal power and astigmatism, internal power and astigmatism, CF for astigmatic data, location of the highest internal refraction zone, and wavefront aberrations. The highest refraction zone was mostly (90%) located in the center in myopes, whereas it was located at the nasal side (71%) in hyperopes. There was a significant correlation between whole ocular and internal powers (P<0.01), but no correlation was observed between corneal and internal powers (P>0.05). Internal astigmatism was mostly against the rule. The mean CF J(0) was 0.63+/-3.78 and CF J(45) was 0.57+/-2.47. The magnitude of the internal astigmatism under the 3-mm zone was correlated with the magnitude

  14. Simulated astigmatism impairs academic-related performance in children.

    PubMed

    Narayanasamy, Sumithira; Vincent, Stephen J; Sampson, Geoff P; Wood, Joanne M

    2015-01-01

    Astigmatism is an important refractive condition in children. However, the functional impact of uncorrected astigmatism in this population is not well established, particularly with regard to academic performance. This study investigated the impact of simulated bilateral astigmatism on academic-related tasks before and after sustained near work in children. Twenty visually normal children (mean age: 10.8 ± 0.7 years; six males and 14 females) completed a range of standardised academic-related tests with and without 1.50 D of simulated bilateral astigmatism (with both academic-related tests and the visual condition administered in a randomised order). The simulated astigmatism was induced using a positive cylindrical lens while maintaining a plano spherical equivalent. Performance was assessed before and after 20 min of sustained near work, during two separate testing sessions. Academic-related measures included a standardised reading test (the Neale Analysis of Reading Ability), visual information processing tests (Coding and Symbol Search subtests from the Wechsler Intelligence Scale for Children) and a reading-related eye movement test (the Developmental Eye Movement test). Each participant was systematically assigned either with-the-rule (WTR, axis 180°) or against-the-rule (ATR, axis 90°) simulated astigmatism to evaluate the influence of axis orientation on any decrements in performance. Reading, visual information processing and reading-related eye movement performance were all significantly impaired by both simulated bilateral astigmatism (p < 0.001) and sustained near work (p < 0.001), however, there was no significant interaction between these factors (p > 0.05). Simulated astigmatism led to a reduction of between 5% and 12% in performance across the academic-related outcome measures, but there was no significant effect of the axis (WTR or ATR) of astigmatism (p > 0.05). Simulated bilateral astigmatism impaired children's performance on a

  15. Vector analysis of astigmatism before and after LASIK: a comparison of two different platforms for treatment of high astigmatism.

    PubMed

    Biscevic, Alma; Bohac, Maja; Koncarevic, Mateja; Anticic, Marija; Dekaris, Iva; Patel, Sudi

    2015-12-01

    To compare the outcomes of astigmatic laser in-situ keratomileusis (LASIK) procedures between two different platforms using J0 and J45 vector analysis. Patients were divided into four groups, depending on the type of astigmatism and laser platform on which they were treated. Astigmatism was between 2 and 7 diopters (D). One hundred and thirty-five patients with myopic astigmatism (246 eyes) and 102 patients with mixed astigmatism (172 eyes) underwent unremarkable LASIK correction on Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S laser platform. The preoperative and postoperative sphere, negative cylinder [C] and axis (ø) of manifest refractions were subjected to vector analysis by calculations of the standard J0 (cos [4π(ø-90)/360]xC/2) and J45 (sin[4π(ø-90)/360]xC/2). Reporting the key results, we found J0 significantly reduced after LASIK in both groups (p < 0.001) but not J45. There was no significant association between individual pairs of pre and postoperative J0 & J45 values. There was no significant difference between the outcomes of the two platforms. Wavelight Allegretto 400Hz and Schwind Amaris 750S showed excellent results for treating patients with astigmatism, regardless whether it is mixed or myopic astigmatism. The J45 did not reduce significantly possibly because of the low number of eyes with oblique astigmatism. There was no genuine difference post-operatively between groups treated on two different laser platforms according to the vector analyses.

  16. A design of PAL with astigmatism

    NASA Astrophysics Data System (ADS)

    Wei, Yefei; Xiang, Huazhong; Zhu, Tianfeng; Chen, Jiabi

    2015-08-01

    Progressive addition lens (PAL) is designed for those who suffer from myopia and presbyopia to have a clear vision from a far distance to a nearby distance. Additionally there are many people that also suffer from astigmatism and need to be corrected. The cylinder power can't be simply added to the diopter of the PAL directly, because the diopter of the PAL needs to be changed smoothly. A methods has been proposed in this article to solve the problem, the freeform surface height of a PAL without astigmatism and the cylindrical lens surface height for the correction of astigmatism are calculated separately. The both two surface heights were added together, then the final surface is produced and shown with the both properties of PALs and cylindrical lenses used to correct the astigmatism.

  17. Corneal collagen denaturation in laser thermokeratoplasty

    NASA Astrophysics Data System (ADS)

    Brinkmann, Ralf; Kampmeier, Juergen; Grotehusmann, Ulf; Vogel, Alfred; Koop, Norbert; Asiyo-Vogel, Mary; Birngruber, Reginald

    1996-05-01

    In laserthermokeratoplasty (LTK) thermal denaturation and shrinkage of corneal collagen is used to correct hyperopia and astigmatism. In order to optimize dosimetry, the temperature at which maximal shrinkage of collagen fibrils occurs is of major interest. Since the exposure time in clinical LTK-treatment is limited to a few seconds, the kinetics of collagen denaturation as a rate process has to be considered, thus the time of exposure is of critical importance for threshold and shrinkage temperatures. We investigated the time-temperature correlation for corneal collagen denaturation within different time domains by turbidimetry of scattered HeNe laser probe light using a temperature controlled water bath and pulsed IR laser irradiation. In the temperature range of 60 degree(s)C to 95 degree(s)C we found an exponential relation between the denaturation time and temperature. For the typical LTK-treatment time of 2 s, a temperature of 95 degree(s)C is needed to induce thermal damage. Use of pulsed Holmium laser radiation gave significant scattering of HeNe laser probe light at calculated temperatures of around 100 degree(s)DC. Rate parameters according to the formalism of Arrhenius were fitted to these results. Force measurements showed the simultaneous onset of light scattering and collagen shrinkage.

  18. Accommodation in Astigmatic Children During Visual Task Performance

    PubMed Central

    Harvey, Erin M.; Miller, Joseph M.; Apple, Howard P.; Parashar, Pavan; Twelker, J. Daniel; Crescioni, Mabel; Davis, Amy L.; Leonard-Green, Tina K.; Campus, Irene; Sherrill, Duane L.

    2014-01-01

    Purpose. To determine the accuracy and stability of accommodation in uncorrected children during visual task performance. Methods. Subjects were second- to seventh-grade children from a highly astigmatic population. Measurements of noncycloplegic right eye spherical equivalent (Mnc) were obtained while uncorrected subjects performed three visual tasks at near (40 cm) and distance (2 m). Tasks included reading sentences with stimulus letter size near acuity threshold and an age-appropriate letter size (high task demands) and viewing a video (low task demand). Repeated measures ANOVA assessed the influence of astigmatism, task demand, and accommodative demand on accuracy (mean Mnc) and variability (mean SD of Mnc) of accommodation. Results. For near and distance analyses, respectively, sample size was 321 and 247, mean age was 10.37 (SD 1.77) and 10.30 (SD 1.74) years, mean cycloplegic M was 0.48 (SD 1.10) and 0.79 diopters (D) (SD 1.00), and mean astigmatism was 0.99 (SD 1.15) and 0.75 D (SD 0.96). Poor accommodative accuracy was associated with high astigmatism, low task demand (video viewing), and high accommodative demand. The negative effect of accommodative demand on accuracy increased with increasing astigmatism, with the poorest accommodative accuracy observed in high astigmats (≥3.00 D) with high accommodative demand/high hyperopia (1.53 D and 2.05 D of underaccommodation for near and distant stimuli, respectively). Accommodative variability was greatest in high astigmats and was uniformly high across task condition. No/low and moderate astigmats showed higher variability for the video task than the reading tasks. Conclusions. Accuracy of accommodation is reduced in uncorrected children with high astigmatism and high accommodative demand/high hyperopia, but improves with increased visual task demand (reading). High astigmats showed the greatest variability in accommodation. PMID:25103265

  19. Improved astigmatic focus error detection method

    NASA Technical Reports Server (NTRS)

    Bernacki, Bruce E.

    1992-01-01

    All easy-to-implement focus- and track-error detection methods presently used in magneto-optical (MO) disk drives using pre-grooved media suffer from a side effect known as feedthrough. Feedthrough is the unwanted focus error signal (FES) produced when the optical head is seeking a new track, and light refracted from the pre-grooved disk produces an erroneous FES. Some focus and track-error detection methods are more resistant to feedthrough, but tend to be complicated and/or difficult to keep in alignment as a result of environmental insults. The astigmatic focus/push-pull tracking method is an elegant, easy-to-align focus- and track-error detection method. Unfortunately, it is also highly susceptible to feedthrough when astigmatism is present, with the worst effects caused by astigmatism oriented such that the tangential and sagittal foci are at 45 deg to the track direction. This disclosure outlines a method to nearly completely eliminate the worst-case form of feedthrough due to astigmatism oriented 45 deg to the track direction. Feedthrough due to other primary aberrations is not improved, but performance is identical to the unimproved astigmatic method.

  20. The visual and functional impacts of astigmatism and its clinical management.

    PubMed

    Read, Scott A; Vincent, Stephen J; Collins, Michael J

    2014-05-01

    To provide a comprehensive overview of research examining the impact of astigmatism on clinical and functional measures of vision, the short and longer term adaptations to astigmatism that occur in the visual system, and the currently available clinical options for the management of patients with astigmatism. The presence of astigmatism can lead to substantial reductions in visual performance in a variety of clinical vision measures and functional visual tasks. Recent evidence demonstrates that astigmatic blur results in short-term adaptations in the visual system that appear to reduce the perceived impact of astigmatism on vision. In the longer term, uncorrected astigmatism in childhood can also significantly impact on visual development, resulting in amblyopia. Astigmatism is also associated with the development of spherical refractive errors. Although the clinical correction of small magnitudes of astigmatism is relatively straightforward, the precise, reliable correction of astigmatism (particularly high astigmatism) can be challenging. A wide variety of refractive corrections are now available for the patient with astigmatism, including spectacle, contact lens and surgical options. Astigmatism is one of the most common refractive errors managed in clinical ophthalmic practice. The significant visual and functional impacts of astigmatism emphasise the importance of its reliable clinical management. With continued improvements in ocular measurement techniques and developments in a range of different refractive correction technologies, the future promises the potential for more precise and comprehensive correction options for astigmatic patients. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  1. Glaucoma surgery and induced astigmatism: a systematic review.

    PubMed

    Chan, Helen H L; Kong, Yu Xiang G

    2017-01-01

    The refractive outcomes of glaucoma surgeries, particularly their effect on astigmatism, are incompletely understood. Trabeculectomy is associated with a considerable amount of with-the-rule astigmatic change in the immediate postoperative period. This is followed by a gradual against-the-rule shift. These changes are altered with the use of mitomycin C (MMC). Non-penetrating surgery such as deep sclerectomy is also associated with a similar or smaller degree of induced astigmatism. Minimally invasive glaucoma surgery appears to be astigmatically neutral. There is no clear evidence regarding refractive outcomes of glaucoma drainage device surgery. Induced astigmatism may account for a reduction in unaided visual acuity in the early postoperative period following a successful trabeculectomy. These changes appear to stabilise at 3 months, and it would be prudent to defer the prescription of new glasses until this time. If sequential cataract surgery is to be performed, toric intraocular lenses can be a useful option for astigmatic correction.

  2. Full-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism.

    PubMed

    Kim, Bu Ki; Mun, Su Joung; Lee, Dae Gyu; Kim, Jae Ryun; Kim, Hyun Seung; Chung, Young Taek

    2015-12-01

    To explore the clinical effects of combined full-thickness astigmatic keratotomy and small-incision lenticule extraction (SMILE) in patients who are inoperable using SMILE alone. We included 13 eyes of 9 patients with high-level or mixed astigmatism who underwent full-thickness astigmatic keratotomy followed by SMILE (secondarily) to correct the residual refractive error. Six months after SMILE, the spherical equivalent was reduced from -4.83 ± 3.26 D to -0.17 ± 0.38 D (P < 0.001), and the astigmatism was reduced from 5.12 ± 0.96 D to 0.21 ± 0.22 D (P < 0.001). The uncorrected and corrected (CDVA) distance visual acuities improved from 1.07 ± 0.62 to 0.02 ± 0.13 (P < 0.001) and from 0.08 ± 0.14 to -0.01 ± 0.14 (P = 0.002), respectively. The CDVA improved by 1 or 2 Snellen lines in 8 cases (61.5%), and there was no loss in CDVA. All procedures were completed without intraoperative or postoperative complications. This combined procedure was effective and safe for the treatment of high-level or mixed astigmatism.

  3. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    PubMed Central

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    AIM To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically. PMID:29181314

  4. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients.

    PubMed

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

  5. Identification of a Candidate Gene for Astigmatism

    PubMed Central

    Lopes, Margarida C.; Hysi, Pirro G.; Verhoeven, Virginie J. M.; Macgregor, Stuart; Hewitt, Alex W.; Montgomery, Grant W.; Cumberland, Phillippa; Vingerling, Johannes R.; Young, Terri L.; van Duijn, Cornelia M.; Oostra, Ben; Uitterlinden, Andre G.; Rahi, Jugnoo S.; Mackey, David A.; Klaver, Caroline C. W.; Andrew, Toby; Hammond, Christopher J.

    2013-01-01

    Purpose. Astigmatism is a common refractive error that reduces vision, where the curvature and refractive power of the cornea in one meridian are less than those of the perpendicular axis. It is a complex trait likely to be influenced by both genetic and environmental factors. Twin studies of astigmatism have found approximately 60% of phenotypic variance is explained by genetic factors. This study aimed to identify susceptibility loci for astigmatism. Methods. We performed a meta-analysis of seven genome-wide association studies that included 22,100 individuals of European descent, where astigmatism was defined as the number of diopters of cylinder prescription, using fixed effect inverse variance-weighted methods. Results. A susceptibility locus was identified with lead single nucleotide polymorphism rs3771395 on chromosome 2p13.3 (meta-analysis, P = 1.97 × 10−7) in the VAX2 gene. VAX2 plays an important role in the development of the dorsoventral axis of the eye. Animal studies have shown a gradient in astigmatism along the vertical plane, with corresponding changes in refraction, particularly in the ventral field. Conclusions. This finding advances the understanding of refractive error, and provides new potential pathways to be evaluated with regard to the development of astigmatism. PMID:23322567

  6. Astigmatism transfer phenomena in the optical parametric amplification process

    NASA Astrophysics Data System (ADS)

    Li, Wenkai; Chen, Yun; Li, Yanyan; Xu, Yi; Guo, Xiaoyang; Lu, Jun; Leng, Yuxin

    2017-01-01

    We numerically and experimentally investigate the astigmatism transfer phenomena in femtosecond optical parametric amplification (OPA). We model the OPA process based on the coupled second-order three-wave nonlinear propagation equations. The numerical and experimental results support that the input pump pulse astigmatism can be transferred into the idler pulse but not the signal pulse, and the idler pulse astigmatism originating from spatial walk-off is less than the idler pulse astigmatism received from the pump. Thus, we can provide a clear understanding of astigmatism transfer mechanisms in the OPA process, and make better use of broadband tunable OPA sources.

  7. Refractive status and optical components of premature babies with or without retinopathy of prematurity at 3-4 years old.

    PubMed

    Ouyang, Li-Juan; Yin, Zheng-Qin; Ke, Ning; Chen, Xin-Ke; Liu, Qin; Fang, Jing; Chen, Lin; Chen, Xiu-Rong; Shi, Hui; Tang, Ling; Pi, Lian-Hong

    2015-01-01

    To investigate the refractive status and optical components of premature babies with or without retinopathy of prematurity (ROP) at 3-4 years old, and to explore the influence of prematurity and ROP on the refractive status and optical components. Premature babies receiving fundus examination were recruited into ROP group and non-ROP group, with age-matched full-term babies as controls. The incidence of myopia was the highest in ROP (3/59, 5.08%). The incidence of astigmatism was significantly different between ROP (37.29%, 22/59) and controls (17.86%, 15/84). The corneal refractive power in ROP and non-ROP was more potent compared with controls (P<0.05); corneal curvature was steeper (P<0.05); lens thickness was thinner (P<0.05); ocular axial length was shorter P<0.05). The gestational age was negatively related to corneal astigmatism and astigmatism, positively associated with vitreous thickness and axial length. The birth-weight was negatively associated with corneal astigmatism, astigmatism and corneal refractive power, positively related to corneal radius of curvature, vitreous thickness and ocular axial length. Premature babies with or without ROP are susceptible to myopia and astigmatism. ROP, prematurity and low birth-weight synergistically influence the development of refractive status and optical components, of which the prematurity and low birth-weight are more important.

  8. Astigmatism and early academic readiness in preschool children.

    PubMed

    Orlansky, Gale; Wilmer, Jeremy; Taub, Marc B; Rutner, Daniella; Ciner, Elise; Gryczynski, Jan

    2015-03-01

    This study investigated the relationship between uncorrected astigmatism and early academic readiness in at-risk preschool-aged children. A vision screening and academic records review were performed on 122 three- to five-year-old children enrolled in the Philadelphia Head Start program. Vision screening results were related to two measures of early academic readiness, the teacher-reported Work Sampling System (WSS) and the parent-reported Ages and Stages Questionnaire (ASQ). Both measures assess multiple developmental and skill domains thought to be related to academic readiness. Children with astigmatism (defined as >|-0.25| in either eye) were compared with children who had no astigmatism. Associations between astigmatism and specific subscales of the WSS and ASQ were examined using parametric and nonparametric bivariate statistics and regression analyses controlling for age and spherical refractive error. Presence of astigmatism was negatively associated with multiple domains of academic readiness. Children with astigmatism had significantly lower mean scores on Personal and Social Development, Language and Literacy, and Physical Development domains of the WSS, and on Personal/Social, Communication, and Fine Motor domains of the ASQ. These differences between children with astigmatism and children with no astigmatism persisted after statistically adjusting for age and magnitude of spherical refractive error. Nonparametric tests corroborated these findings for the Language and Literacy and Physical Health and Development domains of the WSS and the Communication domain of the ASQ. The presence of astigmatism detected in a screening setting was associated with a pattern of reduced academic readiness in multiple developmental and educational domains among at-risk preschool-aged children. This study may help to establish the role of early vision screenings, comprehensive vision examinations, and the need for refractive correction to improve academic success in

  9. Aspheric photorefractive keratectomy for myopia and myopic astigmatism with the SCHWIND AMARIS laser: 2 years postoperative outcomes

    PubMed Central

    Aslanides, Ioannis M.; Padroni, Sara; Arba-Mosquera, Samuel

    2012-01-01

    Purpose To evaluate mid-term refractive outcomes and higher order aberrations of aspheric PRK for low, moderate and high myopia and myopic astigmatism with the AMARIS excimer laser system (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany). Methods This prospective longitudinal study evaluated 80 eyes of 40 subjects who underwent aspheric PRK. Manifest refractive spherical equivalent (MRSE) of up to −10.00 diopters (D) at the spectacle plane with cylinder up to 3.25 was treated. Refractive outcomes and corneal wavefront data (6 mm pupil to the 7th Zernike order) were evaluated out to 2 years postoperatively. Statistical significance was indicated by P < 0.05. Results The mean manifest spherical equivalent refraction (MRSE) was −4.77 ± 2.45 (range, −10.00 D to −0.75 D) preoperatively and −0.12 ± 0.35 D (range, −1.87 D to +0.75 D) postoperatively (P < 0.0001). Postoperatively, 91% (73/80) of eyes had an MRSE within ±0.50 D of the attempted. No eyes lost one or more lines of corrected distance visual acuity (CDVA) and CDVA increased by one or more lines in 26% (21/80) of eyes. Corneal trefoil and corneal higher order aberration root mean square did not statistically change postoperatively compared to preoperatively (P > 0.05, both cases). There was a statistical increase in postoperative coma (+0.12 μm) and spherical aberration (+0.14 μm) compared to preoperatively (P < 0.001, both cases). Conclusion Aspheric PRK provides excellent visual and refractive outcomes with induction in individual corneal aberrations but not overall corneal aberrations.

  10. Topographic hot spot before descemet stripping automated endothelial keratoplasty is associated with postoperative hyperopic shift.

    PubMed

    Shimizu, Tsutomu; Yamaguchi, Takefumi; Satake, Yoshiyuki; Shimazaki, Jun

    2015-03-01

    The aim of this study was to investigate topographic "hot spots" on the anterior corneal surface before Descemet stripping automated endothelial keratoplasty (DSAEK) and their effects on postoperative visual acuity and hyperopic shift. Twenty-seven eyes of 27 patients with bullous keratopathy, who underwent DSAEK were studied. We defined a hot spot as a focal area with relatively high refractive power on the anterior corneal surface in eyes with bullous keratopathy. Refractive spherical equivalent, keratometric value, and corneal topography were retrospectively evaluated using anterior segment optical coherence tomography (AS-OCT). Hot spots were identified in 11 eyes (42.3%) before DSAEK and disappeared in 9 eyes of these eyes (81.8%) at 6 months after DSAEK. AS-OCT revealed focal epithelial thickening in the same areas as the hot spots. There was no significant difference in the postoperative visual acuity between eyes with and without hot spots (P > 0.05). The keratometric value of the anterior corneal surface significantly flattened from 45.7 ± 2.7 diopters (D) before DSAEK to 44.2 ± 2.7 D 1 month after DSAEK in eyes with hot spots (P = 0.01), whereas in eyes without hot spots, there were no significant differences in the keratometric values before and after DSAEK. At 6 months, the refractive change was +1.1 ± 1.3 D in eyes with hot spots and -0.2 ± 0.6 D in eyes without hot spots (P = 0.034). In eyes with focal epithelial thickening, topographic hot spots on the anterior corneal surface were observed using AS-OCT. The hot spots disappeared after DSAEK and had no influence on the postoperative visual acuity.

  11. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK).

    PubMed

    Koenig, Steven B; Covert, Douglas J; Dupps, William J; Meisler, David M

    2007-07-01

    To evaluate visual acuity, refractive outcomes, and endothelial cell density 6 months after Descemet stripping and automated endothelial keratoplasty (DSAEK). We performed an institutional review board-approved prospective study of a surgical case series of 34 patients at 2 institutions undergoing DSAEK for Fuchs endothelial dystrophy, pseudophakic bullous keratopathy, or aphakic bullous keratopathy with or without simultaneous phacoemulsification and intraocular lens implantation. Clinical outcomes, including best spectacle-corrected visual acuity (BSCVA), spherical equivalent refraction, and refractive astigmatism and topographic or keratometric astigmatism, were assessed at the 6-month postoperative examination and compared with preoperative values with paired Student t tests. The change in endothelial cell density from the eye bank examination to 6 months after transplantation was similarly evaluated. BSCVA averaged 20/99 preoperatively and 20/42 postoperatively (P < 0.0001). After DSAEK, 30 (88.2%) of 34 patients showed improved BSCVA, and 21 (61.8%) of the 34 patients achieved a BSCVA of 20/40 or better. For patients not undergoing simultaneous phacoemulsification and intraocular lens implantation, a hyperopic shift in refraction of 1.19 +/- 1.32 D was noted. Refractive astigmatism, topographic astigmatism, and keratometry showed no statistically significant change. Endothelial cell density of donor corneas averaged 2826 +/- 370 cells/mm, whereas the mean postoperative density was 1396 +/- 440 cells/mm. This finding corresponded to an average loss of 1426 cells/mm (50% loss; P = 0.0001). The first half of cases experienced an average cell loss of 1674 cells/mm (59% loss) compared with 1181 (41% loss) in the second half of cases (P = 0.005). Three (9%) of 34 grafts experienced iatrogenic graft failure and required reoperation with new donor tissue. Also, 9 (27%) of 34 grafts experienced dislocation in the early postoperative period and required repositioning

  12. Neuronal adaptation to simulated and optically-induced astigmatic defocus.

    PubMed

    Ohlendorf, Arne; Tabernero, Juan; Schaeffel, Frank

    2011-03-25

    It is well established that spatial adaptation can improve visual acuity over time in the presence of spherical defocus. It is less well known how far adaptation to astigmatic defocus can enhance visual acuity. We adapted subjects to "simulated" and optically-induced "real" astigmatic defocus, and studied how much they adapt and how selective adaptation was for the axis of astigmatism. Ten subjects with a mean age of 26.7±2.4years (range 23-30) were enrolled in the study, three of them myopic (average spherical equivalent (SE)±SD: -3.08±1.42D) and seven emmetropic (average SE±SD: -0.11±0.18D). All had a corrected minimum visual acuity (VA) of logVA 0.0. For adaptation, subjects watched a movie at 4m distance for 10min that was convolved frame-by-frame with an astigmatic point spread function, equivalent to +3D defocus, or they watched an unfiltered movie but with spectacle frames with a 0/+3D astigmatic trial lenses. Subsequently, visual acuity was determined at the same distance, using high contrast letter acuity charts. Four experiments were performed. In experiment (1), simulated astigmatic defocus was presented both for adaptation and testing, in experiment (2) optically-induced astigmatic defocus was presented both for adaptation and testing of visual acuity. In all these cases, the +3D power meridian was at 0°. In experiments (3) and (4), the +3D power meridian was at 0° during adaptation but rotated to 90° during testing. Astigmatic defocus was simulated in experiment (3) but optically-induced in experiment (4). Experiments 1 and 2: adaptation to either simulated or real astigmatic defocus increased visual acuity in both test paradigms, simulated (change in VA 0.086±0.069 log units; p<0.01) and lens-induced astigmatic defocus (change in VA 0.068±0.031 log units; p<0.001). Experiments 3 and 4: when the axis was rotated, the improvement in visual acuity failed to reach significance, both for simulated (change in VA 0.042±0.079 log units; p=0.13) and

  13. Influence of different types of astigmatism on visual acuity.

    PubMed

    Remón, Laura; Monsoriu, Juan A; Furlan, Walter D

    To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were also simulated on the same eyes for comparison. VA was measured in each case and the results, expressed in logMAR units, were represented against of the modulus of the dioptric power vector (blur strength). LogMAR VA varies in a linear fashion with increasing astigmatic blur, being the slope of the line dependent on the accommodative demand in each type of astigmatism. However, in each case, we found no statistically significant differences between the three axes investigated (0°, 45°, 90°). Non-statistically significant differences were found either for the VA achieved with spherical myopic defocus (MD) and mixed astigmatism (MA). VA with simple hyperopic astigmatism (SHA) was higher than with simple myopic astigmatism (SMA), however, in this case non conclusive results were obtained in terms of statistical significance. The VA achieved with imposed compound hyperopic astigmatism (CHA) was highly influenced by the eye's accommodative response. VA is correlated with the blur strength in a different way for each type of astigmatism, depending on the accommodative demand. VA is better when one of the focal lines lie on the retina irrespective of the axis orientation; accommodation favors this situation. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  14. Visual acuity with simulated and real astigmatic defocus.

    PubMed

    Ohlendorf, Arne; Tabernero, Juan; Schaeffel, Frank

    2011-05-01

    To compare the effects of "simulated" and "real" spherical and astigmatic defocus on visual acuity (VA). VA was determined with letter charts that were blurred by calculated spherical or astigmatic defocus (simulated defocus) or were seen through spherical or astigmatic trial lenses (real defocus). Defocus was simulated using ZEMAX and the Liou-Brennan eye model. Nine subjects participated [mean age, 27.2 ± 1.8 years; logarithm of the minimum angle of resolution (logMAR), -0.1]. Three different experiments were conducted in which VA was reduced by 20% (logMAR 0.0), 50% (logMAR 0.2), or 75% (logMAR 0.5) by either (1) imposing positive spherical defocus, (2) imposing positive and negative astigmatic defocus in three axes (0, 45, and 90°), and (3) imposing cross-cylinder defocus in the same three axes as in (2). Experiment (1): there were only minor differences in VA with simulated and real positive spherical defocus. Experiment (2): simulated astigmatic defocus reduced VA twice as much as real astigmatic defocus in all tested axes (p < 0.01 in all cases). Experiment (3): simulated cross-cylinder defocus reduced VA much more than real cross-cylinder defocus (p < 0.01 in all cases), similarly for all three tested axes. The visual system appears more tolerant against "real" spherical, astigmatic, and cross-cylinder defocus than against "simulated" blur. Possible reasons could be (1) limitations in the modeling procedures to simulate defocus, (2) higher ocular aberrations, and (3) fluctuations of accommodation. However, the two optical explanations (2) and (3) cannot account for the magnitude of the effect, and (1) was carefully analyzed. It is proposed that something may be special about the visual processing of real astigmatic and cross-cylinder defocus-because they have less effect on VA than simulations predict.

  15. Risk factors for astigmatism in the Vision in Preschoolers Study.

    PubMed

    Huang, Jiayan; Maguire, Maureen G; Ciner, Elise; Kulp, Marjean Taylor; Cyert, Lynn A; Quinn, Graham E; Orel-Bixler, Deborah; Moore, Bruce; Ying, Gui-Shuang

    2014-05-01

    To determine demographic and refractive risk factors for astigmatism in the Vision in Preschoolers Study. Three- to 5-year-old Head Start preschoolers (N = 4040) from five clinical centers underwent comprehensive eye examinations by study-certified optometrists and ophthalmologists, including monocular visual acuity testing, cover testing, and cycloplegic retinoscopy. Astigmatism was defined as the presence of greater than or equal to +1.5 diopters (D) cylinder in either eye, measured with cycloplegic refraction. The associations of risk factors with astigmatism were evaluated using the odds ratio (OR) and its 95% confidence interval (CI) from logistic regression models. Among 4040 Vision in Preschoolers Study participants overrepresenting children with vision disorders, 687 (17%) had astigmatism, and most (83.8%) had with-the-rule astigmatism. In multivariate analyses, African American (OR, 1.65; 95% CI, 1.22 to 2.24), Hispanic (OR, 2.25; 95% CI, 1.62 to 3.12), and Asian (OR, 1.76; 95% CI, 1.06 to 2.93) children were more likely to have astigmatism than non-Hispanic white children, whereas American Indian children were less likely to have astigmatism than Hispanic, African American, and Asian children (p < 0.0001). Refractive error was associated with astigmatism in a nonlinear manner, with an OR of 4.50 (95% CI, 3.00 to 6.76) for myopia (≤-1.0 D in spherical equivalent) and 1.55 (95% CI, 1.29 to 1.86) for hyperopia (≥+2.0 D) when compared with children without refractive error (>-1.0 D, <+2.0 D). There was a trend of an increasing percentage of astigmatism among older children (linear trend p = 0.06). The analysis for risk factors of with-the-rule astigmatism provided similar results. Among Head Start preschoolers, Hispanic, African American, and Asian race as well as myopic and hyperopic refractive error were associated with an increased risk of astigmatism, consistent with findings from the population-based Multi-ethnic Pediatric Eye Disease Study and the

  16. Corneal Anterior Power Calculation for an IOL in Post-PRK Patients.

    PubMed

    De Bernardo, Maddalena; Iaccarino, Stefania; Cennamo, Michela; Caliendo, Luisa; Rosa, Nicola

    2015-02-01

    After corneal refractive surgery, there is an overestimation of the corneal power with the devices routinely used to measure it. Therefore, the objective of this study was to determine whether, in patients who underwent photorefractive keratectomy (PRK), it is possible to predict the earlier preoperative anterior corneal power from the postoperative (PO) posterior corneal power. A comparison is made using a formula published by Saiki for laser in situ keratomileusis patients and a new one calculated specifically from PRK patients. The Saiki formula was tested in 98 eyes of 98 patients (47 women) who underwent PRK for myopia or myopic astigmatism. Moreover, anterior and posterior mean keratometry (Km) values from a Scheimpflug camera were measured to obtain a specific regression formula. The mean (±SD) preoperative Km was 43.50 (±1.39) diopters (D) (range, 39.25 to 47.05 D). The mean (±SD) Km value calculated with the Saiki formula using the 6 months PO posterior Km was 42.94 (±1.19) D (range, 40.34 to 45.98 D) with a statistically significant difference (p < 0.001). Six months after PRK in our patients, the posterior Km was correlated with the anterior preoperative one by the following regression formula: y = -4.9707x + 12.457 (R² = 0.7656), where x is PO posterior Km and y is preoperative anterior Km, similar to the one calculated by Saiki. Care should be taken in using the Saiki formula to calculate the preoperative Km in patients who underwent PRK.

  17. Defocus and magnification dependent variation of TEM image astigmatism.

    PubMed

    Yan, Rui; Li, Kunpeng; Jiang, Wen

    2018-01-10

    Daily alignment of the microscope is a prerequisite to reaching optimal lens conditions for high resolution imaging in cryo-EM. In this study, we have investigated how image astigmatism varies with the imaging conditions (e.g. defocus, magnification). We have found that the large change of defocus/magnification between visual correction of astigmatism and subsequent data collection tasks, or during data collection, will inevitably result in undesirable astigmatism in the final images. The dependence of astigmatism on the imaging conditions varies significantly from time to time, so that it cannot be reliably compensated by pre-calibration of the microscope. Based on these findings, we recommend that the same magnification and the median defocus of the intended defocus range for final data collection are used in the objective lens astigmatism correction task during microscope alignment and in the focus mode of the iterative low-dose imaging. It is also desirable to develop a fast, accurate method that can perform dynamic correction of the astigmatism for different intended defocuses during automated imaging. Our findings also suggest that the slope of astigmatism changes caused by varying defocuses can be used as a convenient measurement of objective lens rotation symmetry and potentially an acceptance test of new electron microscopes.

  18. On multisoliton solutions of the constant astigmatism equation

    NASA Astrophysics Data System (ADS)

    Hlaváč, Adam

    2015-09-01

    We introduce an algebraic formula producing infinitely many exact solutions of the constant astigmatism equation {z}{yy}+{(1/z)}{xx}+2=0 from a given seed. A construction of corresponding surfaces of constant astigmatism is then a matter of routine. As a special case, we consider multisoliton solutions of the constant astigmatism equation defined as counterparts of famous multisoliton solutions of the sine-Gordon equation. A few particular examples are surveyed as well.

  19. Changes in Visual Function Following Optical Treatment of Astigmatism-Related Amblyopia

    PubMed Central

    Harvey, Erin M.; Dobson, Velma; Miller, Joseph M.; Donaldson, Candice E.

    2009-01-01

    Effects of optical correction on best-corrected grating acuity (vertical (V), horizontal (H), oblique (O)), vernier acuity (V, H, O), contrast sensitivity (1.5, 6.0, and 18.0 cy/deg spatial frequency, V and H), and stereoacuity were evaluated prospectively in 4- to 13-year-old astigmats and a non-astigmatic age-matched control group. Measurements made at baseline (eyeglasses dispensed for astigmats), 6 weeks, and 1 year showed greater improvement in astigmatic than non-astigmatic children for all measures. Treatment effects occurred by 6 weeks, and did not differ by cohort (< 8 vs. 8 years), but astigmatic children did not attain normal levels of visual function. PMID:18261760

  20. The influence of corneal astigmatism on retinal nerve fiber layer thickness and optic nerve head parameter measurements by spectral-domain optical coherence tomography.

    PubMed

    Liu, Lin; Zou, Jun; Huang, Hui; Yang, Jian-guo; Chen, Shao-rong

    2012-05-23

    To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was -1.17 diopters (D; SD 0.64; range -0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was -0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of -1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895.

  1. Stability of corneal topography and wavefront aberrations in young Singaporeans.

    PubMed

    Zhu, Mingxia; Collins, Michael J; Yeo, Anna C H

    2013-09-01

    The aim was to investigate the differences between and variations across time in corneal topography and ocular wavefront aberrations in young Singaporean myopes and emmetropes. We used a videokeratoscope and wavefront sensor to measure the ocular surface topography and wavefront aberrations of the total-eye optics in the morning, midday and late afternoon on two separate days. Topographic data were used to derive the corneal surface wavefront aberrations. Both the corneal and total wavefronts were analysed up to the fourth radial order of the Zernike polynomial expansion and were centred on the entrance pupil (5.0 mm). The participants included 12 young progressing myopes, 13 young stable myopes and 15 young age-matched emmetropes. For all subjects considered together, there were significant changes in some of the aberrations across the day, such as spherical aberration ( Z(4 0)) and vertical coma ( Z (3 - 1)) (repeated measures analysis of variance, p < 0.05). The magnitude of positive spherical aberration ( Z(4 0)) was significantly lower in the progressing myopic group than in the stable myopic (p = 0.04) and emmetropic (p = 0.02) groups. There were also significant interactions between refractive group and time of day for with and against-the-rule astigmatism ( Z(2 2)). Significantly lower fourth-order root mean square of ocular wavefront aberrations were found in the progressing myopic group compared with the stable myopes and emmetropes (p < 0.01). These differences and variations in the corneal and total aberrations may have significance for our understanding of refractive error development and for clinical applications requiring accurate wavefront measurements. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  2. Astigmatism-corrected echelle spectrometer using an off-the-shelf cylindrical lens.

    PubMed

    Fu, Xiao; Duan, Fajie; Jiang, Jiajia; Huang, Tingting; Ma, Ling; Lv, Changrong

    2017-10-01

    As a special kind of spectrometer with the Czerny-Turner structure, the echelle spectrometer features two-dimensional dispersion, which leads to a complex astigmatic condition. In this work, we propose an optical design of astigmatism-corrected echelle spectrometer using an off-the-shelf cylindrical lens. The mathematical model considering astigmatism introduced by the off-axis mirrors, the echelle grating, and the prism is established. Our solution features simplified calculation and low-cost construction, which is capable of overall compensation of the astigmatism in a wide spectral range (200-600 nm). An optical simulation utilizing ZEMAX software, astigmatism assessment based on Zernike polynomials, and an instrument experiment is implemented to validate the effect of astigmatism correction. The results demonstrated that astigmatism of the echelle spectrometer was corrected to a large extent, and high spectral resolution better than 0.1 nm was achieved.

  3. Microcoaxial torsional cataract surgery 1.8 mm versus 2.2 mm: functional and morphological assessment.

    PubMed

    Mastropasqua, Leonardo; Toto, Lisa; Vecchiarino, Luca; Di Nicola, Marta; Mastropasqua, Rodolfo

    2011-01-01

    To compare functional and morphological outcomes of 1.8-mm versus 2.2-mm microincision coaxial cataract surgery (MCCS). Thirty eyes of 30 patients that underwent MCCS were randomized to two groups: 1.8-mm MCCS (group 1: 15 eyes) and 2.2-mm MCCS (group 2: 15 eyes). There were no significant between-group differences in uncorrected visual acuity, best-corrected visual acuity, keratometric astigmatism, and endothelial cell count. One day postoperatively, a greater increase of corneal thickness at the incision site was observed in group 1 compared to group 2 using anterior segment optical coherence tomography with no significant differences in tunnel morphometric features and confocal microscopy showed more tunnel edema in group 1 versus group 2 that resolved in both groups. Both 1.8- and 2.2-mm torsional MCCS were safe and efficient with easy surgical maneuvers and excellent functional and morphological results; 1.8-mm MCCS induced slightly greater tunnel edema shortly after surgery that resolved in the medium term. Copyright 2011, SLACK Incorporated.

  4. Donor cross-linking for keratoplasty: a laboratory evaluation.

    PubMed

    Mukherjee, Achyut; Hayes, Sally; Aslanides, Ioannis; Lanchares, Elena; Meek, Keith M

    2015-12-01

    This laboratory-based investigation compares the topographic outcomes of conventional penetrating keratoplasty with that of a novel procedure in which donor corneas are cross-linked prior to keratoplasty. Penetrating keratoplasty procedures with continuous running sutures were carried out in a porcine whole globe model. Sixty eyes were randomly paired as 'donor' and 'host' tissue before being assigned to one of two groups. In the cross-linked group, donor corneas underwent riboflavin/UVA cross-linking prior to being trephined and sutured to untreated hosts. In the conventional keratoplasty group, both host and donor corneas remained untreated prior to keratoplasty. Topographic and corneal wavefront measurements were performed following surgery, and technical aspects of the procedure evaluated. Mean keratometric astigmatism was significantly lower in the cross-linked donor group at 3.67D (SD 1.8 D), vs. 8.43 D (SD 2.4 D) in the conventional keratoplasty group (p < 0.005). Mean wavefront astigmatism was also significantly reduced in the cross-linked donor group 4.71 D (SD 2.1) vs. 8.29D (SD 3.6) in the conventional keratoplasty group (p < 0.005). Mean RMS higher order aberration was significantly lower in the cross-linked donor group at 1.79 um (SD 0.98), vs. 3.05 um (SD 1.9) in the conventional keratoplasty group (P = 0.02). Qualitative analysis revealed less tissue distortion at the graft-host junction in the cross-linked group. Cross-linking of donor corneas prior to keratoplasty reduces intraoperative induced astigmatism and aberrations in an animal model. Further studies are indicated to evaluate the implications of this potential modification of keratoplasty surgery.

  5. Short-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.

    PubMed

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose-Manuel

    2015-01-01

    To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-point-touch fitting approach. The lens' back optic zone radius (BOZR) was 0.4mm and 0.1mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p<0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p<0.05). Significant reduction was found over time in CCA (p=0.001) and anterior corneal asphericity in both groups (p<0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p<0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p<0.05). Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apical-touch was associated with greater corneal flattening in comparison to three-point-touch lens wear. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  6. Vector analysis of astigmatic correction after small-incision lenticule extraction and femtosecond-assisted LASIK for low to moderate myopic astigmatism.

    PubMed

    Chan, Tommy C Y; Ng, Alex L K; Cheng, George P M; Wang, Zheng; Ye, Cong; Woo, Victor C P; Tham, Clement C Y; Jhanji, Vishal

    2016-04-01

    To compare astigmatic correction between femtosecond-assisted laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). A total of 111 patients were included in this prospective study. Fifty-seven eyes were treated with LASIK and 54 eyes were treated with SMILE for myopia with low to moderate (-0.25 to -4.0 D) astigmatism. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity and manifest refraction were measured preoperatively and at 1 and 3 months postoperatively. Visual and refractive outcomes were reported. Changes in refractive astigmatism were evaluated using vector analysis. Preoperative characteristics were similar between both groups. The UDVA at 1 and 3 months was better in the LASIK group compared with the SMILE group (p<0.009). Postoperative cylinder was higher in the SMILE group (p<0.001). Fewer eyes attained the attempted cylindrical correction in the SMILE group (p<0.029). Vector analysis showed no significant difference in target-induced astigmatism (p=0.091) and angle of error (p>0.596) between the two groups. Surgically induced astigmatism was significantly lower in the SMILE group (p<0.023), while the difference vector (p<0.001) and absolute angle of error (p<0.016) were significantly higher in the SMILE group. No significant difference was found in these parameters between 1 and 3 months in both groups (p>0.122). Our results showed that SMILE offered a less favourable astigmatic correction comparable to femtosecond-assisted LASIK in eyes with low to moderate myopic astigmatism. The alignment of treatment was more variable in SMILE, leading to a lower efficacy compared with LASIK by 3 months postoperatively. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Scintillation of astigmatic dark hollow beams in weak atmospheric turbulence.

    PubMed

    Cai, Yangjian; Eyyuboğlu, Halil T; Baykal, Yahya

    2008-07-01

    The scintillation properties of astigmatic dark hollow beams (DHBs) in weak atmospheric turbulence were investigated in detail. An explicit expression for the on-axis scintillation index of an astigmatic DHB propagating in weak atmospheric turbulence was derived. It was found that the scintillation index value of an astigmatic DHB with suitable astigmatism (i.e., ratio of the beam waist size in the x direction to that in the y direction), dark size, beam waist size, and wavelength can be smaller than that of a stigmatic DHB and that of stigmatic and astigmatic flat-topped, annular, and Gaussian beams in weak atmospheric turbulence particularly at long propagation ranges. Our results will be useful in long-distance free-space optical communications.

  8. More exact solutions of the constant astigmatism equation

    NASA Astrophysics Data System (ADS)

    Hlaváč, Adam

    2018-01-01

    By using Bäcklund transformation for the sine-Gordon equation, new periodic exact solutions of the constant astigmatism equation zyy +(1 / z) xx + 2 = 0 are generated from a seed which corresponds to Lipschitz surfaces of constant astigmatism.

  9. Changes in corneal topography and biomechanical properties after collagen cross linking for keratoconus: 1-year results.

    PubMed

    Sedaghat, Mohammadreza; Bagheri, Mansooreh; Ghavami, Shahri; Bamdad, Shahram

    2015-01-01

    To evaluate changes in corneal topography and biomechanical properties after collagen cross-linking (CXL) for progressive keratoconus. Collagen cross-linking was performed on 97 eyes. We assessed uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA). Corneal topography indices were evaluated using placido disc topography, scanning slit anterior topography (Orbscan II), and rotating Scheimpflug topography (Pentacam). Specular microscopy and corneal biomechanics were evaluated. A 1-year-follow-up results revealed that UCVA improved from 0.31 to 0.45 and BCVA changed from 0.78 to 0.84 (P < 0.001). The mean of average keratometry value decreased from 49.62 to 47.95 D (P < 0.001). Astigmatism decreased from 4.84 to 4.24 D (P < 0.001). Apex corneal thickness decreased from 458.11 to 444.46 μm. Corneal volume decreased from 56.66 to 55.97 mm(3) (P < 0.001). Posterior best fit sphere increased from 55.50 to 46.03 mm (P = 0.025). Posterior elevation increased from 99.2 to 112.22 μm (P < 0.001). Average progressive index increased from 2.26 to 2.56 (P < 0.001). A nonsignificant decrease was observed in mean endothelial count from 2996 to 2928 cell/mm(2) (P = 0.190). Endothelial coefficient of variation (CV) increased nonsignificantly from 18.26 to 20.29 (P = 0.112). Corneal hysteresis changed from 8.18 to 8.36 (P = 0.552) and corneal resistance factor increased from 6.98 to 7.21 (P = 0.202), so these changes were not significant. Visual acuity and K values improved after CXL. In spite of the nonsignificant increase in endothelial cell count and increase in the CV, CLX seems to be a safe treatment for keratoconus. Further studies with larger sample sizes and longer follow-up periods are recommended.

  10. Astigmatism at nearpoint: adventitious, purposeful, and environmental influences.

    PubMed

    Nicholson, S B; Garzia, R P

    1988-12-01

    Previous studies indicate that a number of individuals display significant differences between astigmatism measured at farpoint and nearpoint. Adventitious effects, purposeful lenticular changes and adaptations in response to environmental forces are reviewed as possible sources of this astigmatic variability.

  11. Management of corneal ectasia after LASIK with combined, same-day, topography-guided partial transepithelial PRK and collagen cross-linking: the athens protocol.

    PubMed

    Kanellopoulos, Anastasios John; Binder, Perry S

    2011-05-01

    To evaluate a series of patients with corneal ectasia after LASIK that underwent the Athens Protocol: combined topography-guided photorefractive keratectomy (PRK) to reduce or eliminate induced myopia and astigmatism followed by sequential, same-day ultraviolet A (UVA) corneal collagen cross-linking (CXL). Thirty-two consecutive corneal ectasia cases underwent transepithelial PRK (WaveLight ALLEGRETTO) immediately followed by CXL (3 mW/cm(2)) for 30 minutes using 0.1% topical riboflavin sodium phosphate. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, keratometry, central ultrasonic pachymetry, corneal tomography (Oculus Pentacam), and endothelial cell counts were analyzed. Mean follow-up was 27 months (range: 6 to 59 months). Twenty-seven of 32 eyes had an improvement in UDVA and CDVA of 20/45 or better (2.25 logMAR) at last follow-up. Four eyes showed some topographic improvement but no improvement in CDVA. One of the treated eyes required a subsequent penetrating keratoplasty. Corneal haze grade 2 was present in 2 eyes. Combined, same-day, topography-guided PRK and CXL appeared to offer tomographic stability, even after long-term follow-up. Only 2 of 32 eyes had corneal ectasia progression after the intervention. Seventeen of 32 eyes appeared to have improvement in UDVA and CDVA with follow-up >1.5 years. This technique may offer an alternative in the management of iatrogenic corneal ectasia. Copyright 2011, SLACK Incorporated.

  12. Status of astigmatism-corrected Czerny-Turner spectrometers

    NASA Astrophysics Data System (ADS)

    Li, Xinhang; Dong, Keyan; An, Yan; Wang, Zhenye

    2016-10-01

    In order to analysis and design the Czerny-Turner structure spectrometer with the high resolution and high energy reception, various astigmatism methods of the Czerny-Turner structure are reported. According to the location of plane grating, the astigmatism correction methods are divided into two categories, one is the plane grating in divergent illumination, another is the plane grating in parallel illumination. Basing on the different methods, the anastigmatic principle and methods are analyzed, the merits and demerits of the above methods are summarized and evaluated. The theoretical foundation for design of broadband eliminating astigmatism Czerny-Turner spectrometer and the reference value for the further design work are laid by the summary and analyzing in this paper.

  13. The influence of corneal astigmatism on retinal nerve fiber layer thickness and optic nerve head parameter measurements by spectral-domain optical coherence tomography

    PubMed Central

    2012-01-01

    Background To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Methods Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was −1.17 diopters (D; SD 0.64; range −0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was −0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of −1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. Results No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). Conclusions The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895 PMID:22621341

  14. [Refractive precision and objective quality of vision after toric lens implantation in cataract surgery].

    PubMed

    Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J

    2012-10-01

    To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  15. Astigmatism of the Ex Vivo Human Lens: Surface and Gradient Refractive Index Age-Dependent Contributions.

    PubMed

    Birkenfeld, Judith; de Castro, Alberto; Marcos, Susana

    2015-08-01

    We estimated the contribution of the gradient refractive index (GRIN) and lens surfaces to lens astigmatism and lens astigmatic angle as a function of age in human donor lenses. Human lenses were imaged, ex vivo, with 3D-spectral optical coherence tomography (OCT) and their back focal length was measured using laser ray tracing. The contribution of lens surfaces and GRIN to lens astigmatism were evaluated by computational ray tracing on the GRIN lens and a homogenous equivalent index lens. Astigmatism magnitude and relative astigmatic angle of and between lens surfaces, GRIN lens, and lens with homogeneous refractive index were evaluated, and all results were correlated with age. The magnitude of astigmatism in the anterior lens surface decreased with age (slope = -0.005 diopters [D]/y; r = 0.397, P = 0.018). Posterior surface astigmatism and lens astigmatism were not age-dependent. Presence of GRIN did not alter significantly the magnitude or axis of the lens astigmatism. The astigmatism of GRIN lens and lens with homogeneous refractive index correlated with anterior lens surface astigmatism (GRIN, P = 3.9E - 6, r = 0.693; equivalent refractive index lens, P = 4.1E - 4, r = 0.565). The astigmatic angle of posterior surface, GRIN lens, and homogeneous refractive index lens did not change significantly with age. The axis of lens astigmatism is close to the astigmatic axis of the anterior lens surface. Age-related changes in lens astigmatism appear to be related to changes in the anterior lens astigmatism. The influence of the GRIN on lens astigmatism and the astigmatic axis is minor.

  16. The Limiting Effects of Astigmatism on Visual Performance through Periscopes

    DTIC Science & Technology

    1979-10-01

    NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY SUBMARINE BASE, GROTON, CONN. , ; REPORT NUMBER 905 THE LIMITING EFFECTS OF ASTIGMATISM ...distribution unlimited THE LIMITING EFFECTS OF ASTIGMATISM ON VISUAL PERFORMANCE THROUGH PERISCOPES by S. M. Luria, J. A. S. Kinney, C. L. Schlichting...release; distribution unlimited PROBLEM To determine if the new peri: Navy standards for astigmatic peris« FINDINGS copes make it possible to relax

  17. Goos-Hänchen and Imbert-Fedorov shifts for astigmatic Gaussian beams

    NASA Astrophysics Data System (ADS)

    Ornigotti, Marco; Aiello, Andrea

    2015-06-01

    In this work we investigate the role of the beam astigmatism in the Goos-Hänchen and Imbert-Fedorov shift. As a case study, we consider a Gaussian beam focused by an astigmatic lens and we calculate explicitly the corrections to the standard formulas for beam shifts due to the astigmatism induced by the lens. Our results show that the different focusing in the longitudinal and transverse direction introduced by an astigmatic lens may enhance the angular part of the shift.

  18. Anterior segment parameters of rabbits with rotating Scheimpflug camera.

    PubMed

    Yüksel, Harun; Türkcü, Fatih M; Ari, Şeyhmus; Çinar, Yasin; Cingü, Abdullah K; Şahin, Muhammed; Şahin, Alparslan; Özkurt, Zeynep; Çaça, İhsan

    2015-05-01

    Rabbit is one of the most commonly used experimental animals for corneal studies due to similarity of size to human cornea and ease of manipulation. In this study, we assessed anterior segment parameters of the healthy rabbit eyes with Pentacam HR (Oculus, Wetzlar, Germany). Six-month-old, approximately 2.5-3 kg weighted, 30 female New Zealand rabbits were used in the study. Right eye of the each rabbit was imaged with Pentacam HR under intramuscular ketamine hydrochloride (Ketalar; Eczacibasi, Turkey) anesthesia (50 mg/kg). After the imaging, the rabbits with blinking errors, which results in low-quality images, were excluded from the study. Keratometric readings, central corneal thickness (CCT), anterior chamber depth (ACD), and anterior and posterior elevation values, and lens density were noted. In this study, the flattest and the steepest keratometric values were found as 43.34 ± 1.86, 42.7 ± 2.0, and 43.9 ± 1.9 diopters, respectively. The mean CCT and ACD of rabbits were found as 388 ± 39 μm and 2.08 ± 0.16 mm, respectively. Mean of the anterior and posterior elevation at thinnest point was found as 1.29 ± 4.28 and 3.91 ± 6.17 μm, respectively. Keratometric readings and anterior and posterior elevation values of rabbits were similar to human; however, corneal thickness and anterior chamber depth (ACD) values were lower than humans. © 2014 American College of Veterinary Ophthalmologists.

  19. Association between mode of delivery and astigmatism in preschool children.

    PubMed

    Liu, Fengyang; Yang, Xubo; Tang, Angcang; Liu, Longqian

    2018-03-01

    To determine whether mode of delivery has any impact on astigmatism. This case-control study was performed in the Department of Ophthalmology in 2015. Exposure was mode of delivery [vaginal delivery (VD) or caesarean section (CS), which here included both elective and emergency CS]. Outcome was astigmatism (≥2.5 D), which was determined by cycloplegic refraction. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were computed to assess the associations between mode of delivery and astigmatism from logistic regression models. Of the 659 children studied here (341 boys; mean age, 4.37 years), 440 were born by CS and 219 by VD. The incidence of severe astigmatism (≥2.5 D) in the CS and VD groups was 22.06% and 13.24%, respectively. Children delivered by CS had a 77.9% higher risk of severe astigmatism compared with vaginally delivered children (OR = 1.779; 95% CI, 1.121 to 2.824). After dividing CS into elective CS and emergency CS, children delivered by elective CS had an 87.3% increased risk of severe astigmatism (OR = 1.873; 95% CI, 1.157 to 3.032), but children delivered by emergency CS did not differ from vaginally delivered children. In addition, the children whose mothers had histories of breastfeeding had a 44.6% lower risk of severe astigmatism than children whose mother did not breastfeed them (OR = 0.554, 95% CI, 0.335-0.914). Birth by CS, especially elective CS, increases the risk of severe astigmatism (≥2.50 D) in childhood. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Collagen cross-linking using riboflavin and ultraviolet-a for corneal thinning disorders: an evidence-based analysis.

    PubMed

    Pron, G; Ieraci, L; Kaulback, K

    2011-01-01

    durable?Effectiveness - Refractive Outcomes: What impact does remodeling have on refractive outcomes?Effectiveness - Visual Quality (Symptoms): What impact does corneal cross-linking have on vision quality such as contrast vision, and decreased visual symptoms (halos, fluctuating vision)?Effectiveness - Contact lens tolerance: To what extent does contact lens intolerance improve after corneal cross-linking?Vision-Related QOL: What is the impact of corneal cross-linking on functional visual rehabilitation and quality of life?PATIENT SATISFACTION: Are patients satisfied with their vision following the procedure?Disease Process:What impact does corneal cross-linking have on the underling corneal thinning disease process?Does corneal cross-linking delay or defer the need for a corneal transplant?What is the comparative safety and effectiveness of corneal cross-linking compared with other minimally invasive treatments for corneal ectasia such as intrastromal corneal rings? TARGET POPULATION AND CONDITION Corneal ectasia (thinning) disorders represent a range of disorders involving either primary disease conditions, such as keratoconus (KC) and pellucid marginal corneal degeneration, or secondary iatrogenic conditions, such as corneal thinning occurring after laser in situ keratomileusis (LASIK) refractive surgery. Corneal thinning is a disease that occurs when the normally round dome-shaped cornea progressively thins causing a cone-like bulge or forward protrusion in response to the normal pressure of the eye. The thinning occurs primarily in the stroma layers and is believed to be a breakdown in the collagen process. This bulging can lead to irregular astigmatism or shape of the cornea. Because the anterior part of the cornea is responsible for most of the focusing of the light on the retina, this can then result in loss of visual acuity. The reduced visual acuity can make even simple daily tasks, such as driving, watching television or reading, difficult to perform

  1. The effect of astigmatism axis on visual acuity.

    PubMed

    Mimouni, Michael; Nemet, Achia; Pokroy, Russell; Sela, Tzahi; Munzer, Gur; Kaiserman, Igor

    2017-05-11

    To evaluate the effect of astigmatism axis on uncorrected distance visual acuity (UDVA) in emmetropic eyes that underwent laser refractive surgery. This retrospective study included patients who underwent laser in situ keratomileusis or photorefractive keratectomy between January 2000 and December 2015 at the Care-Vision Laser Centers, Tel Aviv, Israel. Eyes with a 3-month postoperative spherical equivalent between -0.5 D and 0.5 D were included in this study. Eyes with ocular comorbidities and planned ametropia were excluded. Study eyes were divided into 3 groups according to the steep astigmatic axis: with the rule (WTR) (60-120), oblique (31-59 or 121-149), and against the rule (ATR) (0-30 or 150-180). The UDVA of these 3 groups was compared. The oblique group was divided into oblique ATR and oblique WTR, which were compared with each other. A total of 17,416 consecutive eyes of 8,708 patients were studied. The WTR eyes (n = 10,651) had significantly better UDVA (logMAR 0.01 ± 0.08) than the oblique (n = 3,141, logMAR 0.02 ± 0.09) and ATR eyes (n = 3,624, logMAR 0.02 ± 0.10) (p<0.001). The oblique WTR group had significantly better UDVA than the oblique ATR group (p<0.001). The UDVA of the oblique and ATR groups was similar. Stepwise multiple regression analysis showed that the group accounted for 15% of the UDVA variance (p = 0.04). The astigmatic axis has a small but significant effect on UDVA in emmetropic eyes; WTR was better than oblique and ATR astigmatism. Therefore, when correcting astigmatism, it may be preferable to err towards WTR astigmatism.

  2. Comparison between toric and spherical phakic intraocular lenses combined with astigmatic keratotomy for high myopic astigmatism.

    PubMed

    Zheng, Lin-Yan; Zhu, Shuang-Qian; Su, Yan-Feng; Zou, Hu-Yong; Wang, Qin-Mei; Yu, A-Yong

    2017-01-01

    To compare the outcomes of a toric phakic intraocular lens (PIOL) and a spherical PIOL combined with astigmatic keratotomy (AK) for the correction of high myopic astigmatism. This study enrolled patients with high myopic astigmatism, including 30 eyes (22 patients) that received a toric PIOL implantation (TICL group), and 32 eyes (24 patients) that received combined AK and a spherical PIOL implantation (AK+ ICL group). The outcomes were compared between the two groups before surgery, and at the following time points after surgery: 1 week, 1, 3, 6 months, and 1, 2 years. Preoperatively, the mean manifest spherical equivalent (SE) was -14.14 ± 2.12 D in the TICL group and -14.83 ± 2.79 D in the AK + ICL group ( P  = 0.28), and the mean manifest refractive cylinder, -2.87 ± 1.09 D and -2.58 ± 0.85 D, respectively ( P  = 0.28). Two years postoperatively, the mean safety index was 1.53 ± 0.55 in the TICL group and 1.60 ± 0.70 in the AK + ICL group ( P  = 1.00), and the mean efficacy index, 1.18 ± 0.45 and 1.38 ± 0.52, respectively ( P  = 0.86). The mean manifest refractive cylinder correction was 1.94 ± 1.07 D in the TICL group and 1.39 ± 0.71 D in the AK + ICL group ( P  = 0.02). The mean changes in SE and refractive cylinder from 1 week to 2 years were less than 0.50 D in both groups. Both TICL implantation and AK + ICL implantation are a good alternative for correction of astigmatism in addition to high myopia. TICL implantation has better predictability in correction of high myopic astigmatism. NCT03202485.

  3. Lens-induced astigmatism after perforating scleral injury.

    PubMed

    Ludwig, Klaus; Moradi, Said; Rudolph, Guenther; Boergen, Klaus Peter

    2002-10-01

    Within 6 weeks of a penetrating scleral injury that included vitreous prolapse, a 6-year-old boy developed lenticular astigmatism with a regular component of 5.5 diopters (D). Visible indentational folds in the posterior lens capsule, caused by anterior vitreous fibers and anterior hyaloid, were presumed to be the origin of the astigmatism. Because of decreased visual acuity and the suspicion of early amblyopia, a pars plana vitrectomy with removal of the anterior hyaloid and the critical anterior vitreous fibers was performed. Dense fibrotic tissue between the lens equator and the site of the original scleral perforation limited reduction of the preoperative astigmatism to 4.0 D. However, the striae-like lenticular deformation disappeared completely, and full visual acuity was restored. During the 12-month follow-up, the lens remained clear

  4. Corneal oedema in a unilateral corneal graft patient induced by high Dk mini-scleral contact lens.

    PubMed

    Guillon, Natalie C; Godfrey, Andrew; Hammond, David S

    2018-05-24

    Scleral contact lenses are increasingly becoming accepted as the method of choice for visual correction of the irregular cornea. As such, cases have surfaced which demonstrate complications arising from mini-scleral lenses. Identification of these issues and adjusting fitting techniques accordingly is necessary for reducing the risks associated with mini-scleral lens wear. A 58 year old Caucasian female was referred for rigid gas permeable contact lens fitting for correction of right irregular astigmatism post penetrating keratoplasty. After four months of successful mini-scleral contact lens wear, the patient experienced a graft rejection episode and treated accordingly, then refit with a new mini-scleral lens. Five months after the lens refit, the patient presented with complaints of hazy vision, and a diagnosis of lens-induced corneal oedema made. Increased awareness of the potential complications of mini-scleral lenses is necessary to encourage and enforce mini-scleral lens fitting techniques that meet the requirements of minimum vault but adequate protection of the compromised cornea. Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Anterior stromal puncture with staining: A modified technique for preoperative reference corneal marking for toric lenses and its retrospective analyses.

    PubMed

    Bhandari, Sahil; Nath, Manas

    2016-08-01

    Toric intraocular lenses (IOLs) are an effective way of compensating preexisting corneal astigmatism during cataract surgery. To achieve success, it is imperative to align the toric IOLs in desired position and preoperative reference marking is one among the three important steps for accurate alignment. To make the marking procedure simpler and effective, we have modified the conventional three-step slit lamp-based technique. Patient is seated in front of the slit lamp and asked to keep the chin over chin rest. A 26-gauge bent needle with tip stained by sterile blue ink marker is used to make anterior stromal puncture (ASP) at the edges of horizontal 180° axis near the limbus. A total of 58 eyes were retrospectively evaluated. Mean (+/-SD) IOL deviation on day 1 and day 30 was 5.7 ± 6.5° and 4.7 ± 5.6°, respectively. Median IOL misalignment on day 1 and day 30 was 3°. Redialing of IOL was required in 2 (3.4%) eyes only, all of which were performed within 1 week of surgery. In total, 2 (3.7%) eyes had a residual astigmatism of - 0.5 Dcyl and - 1.0 Dcyl, respectively. ASP is an effective technique for reference marking, technically simpler and can be practiced by most of the surgeons. It avoids the necessity of high-end sophisticated machinery and gives a better platform for the reference corneal marking along with the benefit of reproducibility and simplicity.

  6. Corneal dystrophies

    PubMed Central

    Klintworth, Gordon K

    2009-01-01

    The term corneal dystrophy embraces a heterogenous group of bilateral genetically determined non-inflammatory corneal diseases that are restricted to the cornea. The designation is imprecise but remains in vogue because of its clinical value. Clinically, the corneal dystrophies can be divided into three groups based on the sole or predominant anatomical location of the abnormalities. Some affect primarily the corneal epithelium and its basement membrane or Bowman layer and the superficial corneal stroma (anterior corneal dystrophies), the corneal stroma (stromal corneal dystrophies), or Descemet membrane and the corneal endothelium (posterior corneal dystrophies). Most corneal dystrophies have no systemic manifestations and present with variable shaped corneal opacities in a clear or cloudy cornea and they affect visual acuity to different degrees. Corneal dystrophies may have a simple autosomal dominant, autosomal recessive or X-linked recessive Mendelian mode of inheritance. Different corneal dystrophies are caused by mutations in the CHST6, KRT3, KRT12, PIP5K3, SLC4A11, TACSTD2, TGFBI, and UBIAD1 genes. Knowledge about the responsible genetic mutations responsible for these disorders has led to a better understanding of their basic defect and to molecular tests for their precise diagnosis. Genes for other corneal dystrophies have been mapped to specific chromosomal loci, but have not yet been identified. As clinical manifestations widely vary with the different entities, corneal dystrophies should be suspected when corneal transparency is lost or corneal opacities occur spontaneously, particularly in both corneas, and especially in the presence of a positive family history or in the offspring of consanguineous parents. Main differential diagnoses include various causes of monoclonal gammopathy, lecithin-cholesterol-acyltransferase deficiency, Fabry disease, cystinosis, tyrosine transaminase deficiency, systemic lysosomal storage diseases (mucopolysaccharidoses

  7. Astigmatism-free Czerny-Turner compact spectrometer with cylindrical mirrors.

    PubMed

    Xia, Guo; Wu, Su; Wang, Guodong; Hu, Mingyong; Xing, Jinyu

    2017-11-10

    A modified optical design for a broadband, high resolution, astigmatism-free Czerny-Turner spectrometer is proposed. Astigmatism is corrected by using cylindrical mirrors over a broad spectral range. The theory and method for astigmatism correction are thoroughly analyzed. The comparison between the modified Czerny-Turner spectrometer and the traditional Czerny-Turner spectrometer is also described in detail. The ray-tracing results show that the RMS spot radius has decreased to 4.2 μm at the central wavelength and 17 μm at the wedge wavelength.

  8. Lenticular meridional astigmatism secondary to iris mesectodermal leiomyoma.

    PubMed

    Chalam, K V; Cutler Peck, Carolee M; Grover, Sandeep; Radhakrishnan, Ravi

    2012-01-01

    A 61-year-old African American man presented with decreased vision of 2 months duration. Examination revealed a significant lenticular astigmatism and sectoral cataract as a result of an amelanotic iris lesion. Slitlamp optical coherence tomography (OCT) revealed angle crowding. An excisional biopsy was performed along with phacoemulsification in the right eye, with intraocular lens implantation for meridional lenticular astigmatism. Histopathology and histoimmunochemistry confirmed a diagnosis of uveal mesectodermal leiomyoma. Lenticular astigmatism may be a subtle sign of an anterior segment tumor. Anterior segment slitlamp OCT is an effective tool in diagnosing as well as monitoring small interval changes in these types of tumors. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Topography-Guided Transepithelial Surface Ablation in the Treatment of Moderate to High Astigmatism.

    PubMed

    Chen, Xiangjun; Stojanovic, Aleksandar; Simonsen, David; Wang, Xiaorui; Liu, Yanhua; Utheim, Tor Paaske

    2016-06-01

    To analyze the outcomes of treatment of astigmatism of 2.00 diopters (D) or greater with topography-guided transepithelial surface ablation. Retrospective analysis of a series of 206 eyes divided into two groups: myopic astigmatism (153 eyes) and mixed astigmatism (53 eyes). All cases were treated with topography-guided transepithelial surface ablation. Efficacy, safety, and predictability were evaluated, and vector analysis of cylindrical correction was performed. The median preoperative spherical equivalent was -2.63 and -0.63 D for the myopic and mixed astigmatism groups, respectively, with median cylinder of -2.50 D. Postoperative uncorrected distance visual acuity was 20/20 or better in 92% and 83% of eyes in the myopic and mixed astigmatism groups, respectively; the corresponding efficacy indices were 1.00 and 0.96 and residual astigmatism of 0.50 D or less was present in 82.4% and 56.7% of eyes in the myopic and mixed astigmatism groups, respectively. The arithmetic mean magnitude of the difference vector was 0.38 (myopic) and 0.65 (mixed) D. Difference vector magnitude was positively correlated with the magnitude of target induced astigmatism in both groups. The geometric mean coefficient of adjustment index was 1.04 and 1.19, representing undercorrection of 4% and 19% in the myopic and mixed astigmatism groups, respectively. Topography-guided transepithelial ablation is a safe, effective, and predictable treatment for moderate to high astigmatism. [J Refract Surg. 2016;32(6):418-425.]. Copyright 2016, SLACK Incorporated.

  10. [Recurrent Corneal Erosions in Epithelial Corneal Dystrophies].

    PubMed

    Geerling, Gerd; Lisch, Walter; Finis, David

    2018-06-01

    The corneal epithelium is the most important structure of the ocular optical system. Recurrent corneal erosions can result from inflammation, trauma, degeneration and dystrophies. Epithelial basement membrane dystrophy (EBMD), epithelial recurrent erosion dystrophy (ERED) and Francheschetti and Meesmann's epithelial corneal dystrophy (MECD) can all - besides other signs and symptoms - result in more or less frequent corneal erosions. The pathomechanisms involved however are different. In EBMD, corneal erosions are facultative and clinical signs are often subtle. Aberrant basement membrane structures are associated with thinning of the epithelium and can be clinically identified as maps or fingerprints. In ERED, recurrent corneal erosions are - predominantly in the first decades of life - always present. A defect in the COL17A1 gene results in a dysfunctional hemidesmosome. In MECD, punctate corneal erosions are less frequent and result from intraepithelial microcysts which open spontaneously onto the ocular surface. Usually lubricants, therapeutic contact lenses and sometimes epithelial debridement and phototherapeutic keratectomy are the mainstay for treating corneal erosions in these three dystrophies. Georg Thieme Verlag KG Stuttgart · New York.

  11. MAGNETIC DEFLEXION OF ELECTRON BEAMS WITHOUT ASTIGMATISM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archard, G.D.; Mulvey, T.

    1958-09-01

    An electron beam passing through a magnetic defiecting field is, in general, subject to astigmatism. For circular pole pieces, this takes the form of focusing in the plane of deflection; for square pole pieces, focusing perpendicular to the pinne of deflection. Deflection free from astigmatism can be achieved by means of circular pole-pieces from which semicircular portions have been removed. An application of this to reflection electron microsccpy is described. (auth)

  12. Stability of therapeutic retreatment of corneal wavefront customized ablation with the SCHWIND CAM: 4-year data.

    PubMed

    Aslanides, Ioannis M; Kolli, Sai; Padroni, Sara; Padron, Sara; Arba Mosquera, Samuel

    2012-05-01

    To evaluate the long-term outcomes of aspheric corneal wavefront ablation profiles for excimer laser retreatment. Eighteen eyes that had previously undergone LASIK or photorefractive keratectomy (PRK) were retreated with LASIK using the corneal wavefront ablation profile. Custom Ablation Manager (SCHWIND eye-tech-solutions, Kleinostheim, Germany) software and the ESIRIS flying spot excimer laser system (SCHWIND) were used to perform the ablations. Refractive outcomes and wavefront data are reported up to 4 years after retreatment. Pre- and postoperative data were compared with Student t tests and (multivariate) correlation tests. P<.05 was considered statistically significant. A bilinear correlation of various postoperative wavefront aberrations versus planned correction and preoperative aberration was performed. Mean manifest refraction spherical equivalent (MRSE) before retreatment was -0.38±1.85 diopters (D) and -0.09±0.22 D at 6 months and -0.10±0.38 D at 4 years postoperatively. The reduction in MRSE was statistically significant at both postoperative time points (P<.005). Postoperative aberrations were statistically lower (spherical aberration P<.05; coma P<.005; root-mean-square higher order aberration P<.0001) at 4 years postoperatively. Distribution of the postoperative uncorrected distance visual acuity (P<.0001) and corrected distance visual acuity (P<.01) were statistically better than preoperative values. Aspheric corneal wavefront customization with the ESIRIS yields visual, optical, and refractive results comparable to those of other wavefront-guided customized techniques for the correction of myopia and myopic astigmatism. The corneal wavefront customized approach shows its strength in cases where abnormal optical systems are expected. Systematic wavefront customized corneal ablation appears safe and efficacious for retreatment cases. Copyright 2012, SLACK Incorporated.

  13. A case report of central toxic keratopathy in a patient post TransPRK (followed by corneal collagen cross-linking)

    PubMed Central

    Davey, Nicholas; Aslanides, Ioannis M; Selimis, Vasilis

    2017-01-01

    Purpose The purpose of this article is to report a case of central toxic keratopathy in a patient post transepithelial photorefractive keratectomy (TransPRK), followed immediately by corneal collagen cross-linking. Methods This article describes the case of a 26-year-old male after bilateral aberration-free, TransPRK laser (Schwind Amaris 750S). The procedure was performed for compound myopic astigmatism in November 2015, followed immediately by accelerated corneal collagen cross-linking for early keratoconus. Results From day 3 post-op, tear film debris underneath both contact lenses with corneal haze and early, progressive central anterior stromal opacity formation only in the left eye were noted. At 2 weeks post-op, the left eye was noted to have a significant hyperopic shift with central corneal thinning in the anterior stroma. A central anterior stromal dense opacity had formed in the left eye with the surrounding superficial stromal haze. As of month 2, the opacity gradually started to improve in size and density. The hyperopic shift peaked at 2 months and continued to improve, largely due to epithelial compensation with a gradual recovery of stromal thickness. Conclusion The question remains as to what provokes the typical central corneal necrosis/thinning in central toxic keratopathy. We hypothesize that the space between the contact lens and the corneal surface post TransPRK is prone to a “pseudo-interface pathology” that could mimic diffuse lamellar keratitis-like pathology. Suboptimal lid hygiene, resulting in tear film combinations of bacteria, inflammatory cells, matrix metalloproteinases and other proteolytic enzymes, contributes to the degradation of vulnerable, exposed collagen stromal tissue post TransPRK or any surface corneal ablation. Refractive surgeons should maintain a healthy lid margin and tear film, especially in contact lens wearers, to prevent potential complications in refractive surgery procedures. PMID:28450791

  14. A case report of central toxic keratopathy in a patient post TransPRK (followed by corneal collagen cross-linking).

    PubMed

    Davey, Nicholas; Aslanides, Ioannis M; Selimis, Vasilis

    2017-01-01

    The purpose of this article is to report a case of central toxic keratopathy in a patient post transepithelial photorefractive keratectomy (TransPRK), followed immediately by corneal collagen cross-linking. This article describes the case of a 26-year-old male after bilateral aberration-free, TransPRK laser (Schwind Amaris 750S). The procedure was performed for compound myopic astigmatism in November 2015, followed immediately by accelerated corneal collagen cross-linking for early keratoconus. From day 3 post-op, tear film debris underneath both contact lenses with corneal haze and early, progressive central anterior stromal opacity formation only in the left eye were noted. At 2 weeks post-op, the left eye was noted to have a significant hyperopic shift with central corneal thinning in the anterior stroma. A central anterior stromal dense opacity had formed in the left eye with the surrounding superficial stromal haze. As of month 2, the opacity gradually started to improve in size and density. The hyperopic shift peaked at 2 months and continued to improve, largely due to epithelial compensation with a gradual recovery of stromal thickness. The question remains as to what provokes the typical central corneal necrosis/thinning in central toxic keratopathy. We hypothesize that the space between the contact lens and the corneal surface post TransPRK is prone to a "pseudo-interface pathology" that could mimic diffuse lamellar keratitis-like pathology. Suboptimal lid hygiene, resulting in tear film combinations of bacteria, inflammatory cells, matrix metalloproteinases and other proteolytic enzymes, contributes to the degradation of vulnerable, exposed collagen stromal tissue post TransPRK or any surface corneal ablation. Refractive surgeons should maintain a healthy lid margin and tear film, especially in contact lens wearers, to prevent potential complications in refractive surgery procedures.

  15. A simplified focusing and astigmatism correction method for a scanning electron microscope

    NASA Astrophysics Data System (ADS)

    Lu, Yihua; Zhang, Xianmin; Li, Hai

    2018-01-01

    Defocus and astigmatism can lead to blurred images and poor resolution. This paper presents a simplified method for focusing and astigmatism correction of a scanning electron microscope (SEM). The method consists of two steps. In the first step, the fast Fourier transform (FFT) of the SEM image is performed and the FFT is subsequently processed with a threshold to achieve a suitable result. In the second step, the threshold FFT is used for ellipse fitting to determine the presence of defocus and astigmatism. The proposed method clearly provides the relationships between the defocus, the astigmatism and the direction of stretching of the FFT, and it can determine the astigmatism in a single image. Experimental studies are conducted to demonstrate the validity of the proposed method.

  16. Correction of high amounts of astigmatism through orthokeratology. A case report

    PubMed Central

    Baertschi, Michael; Wyss, Michael

    2011-01-01

    The purpose of this case report is to introduce a method for a successful treatment of high astigmatism with a new orthokeratology design, called FOKX (Falco Kontaktlinsen, Switzerland). This novel toric orthokeratology contact lens design, the fitting approach and the performance of FOKX lenses will be illustrated in the form of a case report. Correcting astigmatism with orthokeratology offers a new perspective for all patients suffering astigmatism.

  17. Development of a real-time wave field reconstruction TEM system (II): correction of coma aberration and 3-fold astigmatism, and real-time correction of 2-fold astigmatism.

    PubMed

    Tamura, Takahiro; Kimura, Yoshihide; Takai, Yoshizo

    2018-02-01

    In this study, a function for the correction of coma aberration, 3-fold astigmatism and real-time correction of 2-fold astigmatism was newly incorporated into a recently developed real-time wave field reconstruction TEM system. The aberration correction function was developed by modifying the image-processing software previously designed for auto focus tracking, as described in the first article of this series. Using the newly developed system, the coma aberration and 3-fold astigmatism were corrected using the aberration coefficients obtained experimentally before the processing was carried out. In this study, these aberration coefficients were estimated from an apparent 2-fold astigmatism induced under tilted-illumination conditions. In contrast, 2-fold astigmatism could be measured and corrected in real time from the reconstructed wave field. Here, the measurement precision for 2-fold astigmatism was found to be ±0.4 nm and ±2°. All of these aberration corrections, as well as auto focus tracking, were performed at a video frame rate of 1/30 s. Thus, the proposed novel system is promising for quantitative and reliable in situ observations, particularly in environmental TEM applications.

  18. Astigmatism error modification for absolute shape reconstruction using Fourier transform method

    NASA Astrophysics Data System (ADS)

    He, Yuhang; Li, Qiang; Gao, Bo; Liu, Ang; Xu, Kaiyuan; Wei, Xiaohong; Chai, Liqun

    2014-12-01

    A method is proposed to modify astigmatism errors in absolute shape reconstruction of optical plane using Fourier transform method. If a transmission and reflection flat are used in an absolute test, two translation measurements lead to obtain the absolute shapes by making use of the characteristic relationship between the differential and original shapes in spatial frequency domain. However, because the translation device cannot guarantee the test and reference flats rigidly parallel to each other after the translations, a tilt error exists in the obtained differential data, which caused power and astigmatism errors in the reconstructed shapes. In order to modify the astigmatism errors, a rotation measurement is added. Based on the rotation invariability of the form of Zernike polynomial in circular domain, the astigmatism terms are calculated by solving polynomial coefficient equations related to the rotation differential data, and subsequently the astigmatism terms including error are modified. Computer simulation proves the validity of the proposed method.

  19. Topography-guided treatment of irregular astigmatism with the wavelight excimer laser.

    PubMed

    Jankov, Mirko R; Panagopoulou, Sophia I; Tsiklis, Nikolaos S; Hajitanasis, Georgos C; Aslanides, loannis M; Pallikaris, loannis G

    2006-04-01

    To evaluate the feasibility, safety, and predictability of correcting high irregular astigmatism in symptomatic eyes with the use of topography-guided photoablation. In a prospective, non-comparative case series, 16 consecutive symptomatic eyes of 11 patients with small hyperopic and myopic excimer laser optical zones, decentered and irregular ablation after corneal graft, and corneal scars were operated. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest and cycloplegic refraction, and corneal topography, with asphericity and regularity, were analyzed. LASIK (n = 10) and photorefractive keratectomy (n = 6) were performed using the ALLEGRETTO WAVE excimer laser and T-CAT software (Topography-guided Customized Ablation Treatment; WaveLight Laser Technologie AG, Erlangen, Germany). In the LASIK group, UCVA improved from 0.81 +/- 0.68 IogMAR (20/130) (range: 0.2 to 2.0) to 0.29 +/- 0.21 logMAR (20/39) (range: 0.1 to 0.7) at 6 months. In the PRK group, mean UCVA improved from 0.89 +/- 0.87 IogMAR (20/157) (range: 0.1 to 2.0) to 0.42 +/- 0.35 logMAR (20/53) (range: 0.1 to 1.0) at 6 months. Best spectacle-corrected visual acuity did not change significantly in either group. One PRK patient lost one line of BSCVA. Refractive cylinder for the LASIK group improved from -2.53 +/- 1.71 diopters (D) (range: -0.75 to -5.75 D) to -1.28 +/- 0.99 D (range: 0 to -2.50 D) at 6 months. Refractive cylinder in the PRK group improved from -2.21 +/- 2.11 D (range: -0.25 to -5.50 D) to -1.10 +/- 0.42 D (range: -0.50 to -1.50 D). Index of surface irregularity showed a decrease from 60 +/- 12 (range: 46 to 89) to 50 +/- 9 (range: 32 to 63) at 6 months in the LASIK group whereas no significant change was noted in the PRK group. Subjective symptoms, such as glare, halos, ghost images, starbursts, and monocular diplopia, were not present postoperatively. Topography-guided LASIK and PRK resulted in a significant reduction of refractive cylinder and

  20. Persistent Epithelial Defects and Corneal Opacity After Collagen Cross-Linking With Substitution of Dextran (T-500) With Dextran Sulfate in Compounded Topical Riboflavin.

    PubMed

    Höllhumer, Roland; Watson, Stephanie; Beckingsale, Peter

    2017-03-01

    Collagen cross-linking (CXL) is a commonly performed procedure to prevent the progression of keratoconus. Riboflavin is an essential part of the procedure, which facilitates both the cross-linking process and protection of intraocular structures. Dextran can be added to riboflavin to create an isotonic solution. This case report highlights the importance of compounding riboflavin with the correct dextran solution. A retrospective case series. Six eyes of 4 male patients with keratoconus aged from 20 to 38 years underwent CXL with substitution of 20% dextran (T-500) with 20% dextran sulfate in a compounded riboflavin 0.1% solution. Postoperatively, persistent corneal epithelial defects, stromal haze, and then scarring occurred. Corneal transplantation was performed for visual rehabilitation but was complicated by graft rejection followed by failure (n = 1 eye), dehiscence (n = 4), cataract (n = 2), post-laser ablation haze (n = 1), and steroid-induced glaucoma (n = 2). The visual outcome was <6/18 in all 6 cases because of irregular astigmatism and stromal haze. Thinning, vascularization, and scarring of the residual host tissue were noted. Substitution of dextran (T-500) with dextran sulfate in riboflavin solutions during CXL results in loss of vision from permanent corneal opacity. Residual host changes may compromise the results of corneal transplantation.

  1. Does correcting astigmatism with toric lenses improve driving performance?

    PubMed

    Cox, Daniel J; Banton, Thomas; Record, Steven; Grabman, Jesse H; Hawkins, Ronald J

    2015-04-01

    Driving is a vision-based activity of daily living that impacts safety. Because visual disruption can compromise driving safety, contact lens wearers with astigmatism may pose a driving safety risk if they experience residual blur from spherical lenses that do not correct their astigmatism or if they experience blur from toric lenses that rotate excessively. Given that toric lens stabilization systems are continually improving, this preliminary study tested the hypothesis that astigmats wearing toric contact lenses, compared with spherical lenses, would exhibit better overall driving performance and driving-specific visual abilities. A within-subject, single-blind, crossover, randomized design was used to evaluate driving performance in 11 young adults with astigmatism (-0.75 to -1.75 diopters cylinder). Each participant drove a highly immersive, virtual reality driving simulator (210 degrees field of view) with (1) no correction, (2) spherical contact lens correction (ACUVUE MOIST), and (3) toric contact lens correction (ACUVUE MOIST for Astigmatism). Tactical driving skills such as steering, speed management, and braking, as well as operational driving abilities such as visual acuity, contrast sensitivity, and foot and arm reaction time, were quantified. There was a main effect for type of correction on driving performance (p = 0.05). Correction with toric lenses resulted in significantly safer tactical driving performance than no correction (p < 0.05), whereas correction with spherical lenses did not differ in driving safety from no correction (p = 0.118). Operational tests differentiated corrected from uncorrected performance for both spherical (p = 0.008) and toric (p = 0.011) lenses, but they were not sensitive enough to differentiate toric from spherical lens conditions. Given previous research showing that deficits in these tactical skills are predictive of future real-world collisions, these preliminary data suggest that correcting low to moderate

  2. Spontaneous Corneal Hydrops in a Patient with a Corneal Ulcer

    PubMed Central

    Batawi, Hatim; Kothari, Nikisha; Camp, Andrew; Bernhard, Luis; Karp, Carol L.; Galor, Anat

    2016-01-01

    Purpose We report the case of a 77-year-old man with no history of keratoconus or other ectatic disorders who presented with corneal hydrops in the setting of a corneal ulcer. The risk factors, pathogenesis and treatment options of corneal hydrops are discussed. Method This is an observational case report study. Results A 77-year-old man presented with a 1-day history of severe pain, redness, mucous discharge and photophobia in the right eye. A slit-lamp examination of the right eye showed an area of focal corneal edema and protrusion. Within the area of edema and protrusion, there was an infiltrate with an overlying epithelial defect consistent with an infectious corneal ulcer. The Seidel test showed no leakage, so a clinical diagnosis of corneal hydrops associated with nonperforated corneal ulcer was made. With appropriate antibiotic treatment, the corneal ulcer and hydrops both resolved over a 1-month period. Conclusion Corneal hydrops can occur in the setting of corneal infections. PMID:26889160

  3. Spontaneous Corneal Hydrops in a Patient with a Corneal Ulcer.

    PubMed

    Batawi, Hatim; Kothari, Nikisha; Camp, Andrew; Bernhard, Luis; Karp, Carol L; Galor, Anat

    2016-01-01

    We report the case of a 77-year-old man with no history of keratoconus or other ectatic disorders who presented with corneal hydrops in the setting of a corneal ulcer. The risk factors, pathogenesis and treatment options of corneal hydrops are discussed. This is an observational case report study. A 77-year-old man presented with a 1-day history of severe pain, redness, mucous discharge and photophobia in the right eye. A slit-lamp examination of the right eye showed an area of focal corneal edema and protrusion. Within the area of edema and protrusion, there was an infiltrate with an overlying epithelial defect consistent with an infectious corneal ulcer. The Seidel test showed no leakage, so a clinical diagnosis of corneal hydrops associated with nonperforated corneal ulcer was made. With appropriate antibiotic treatment, the corneal ulcer and hydrops both resolved over a 1-month period. Corneal hydrops can occur in the setting of corneal infections.

  4. Corneal biomechanical properties from air-puff corneal deformation imaging

    NASA Astrophysics Data System (ADS)

    Marcos, Susana; Kling, Sabine; Bekesi, Nandor; Dorronsoro, Carlos

    2014-02-01

    The combination of air-puff systems with real-time corneal imaging (i.e. Optical Coherence Tomography (OCT), or Scheimpflug) is a promising approach to assess the dynamic biomechanical properties of the corneal tissue in vivo. In this study we present an experimental system which, together with finite element modeling, allows measurements of corneal biomechanical properties from corneal deformation imaging, both ex vivo and in vivo. A spectral OCT instrument combined with an air puff from a non-contact tonometer in a non-collinear configuration was used to image the corneal deformation over full corneal cross-sections, as well as to obtain high speed measurements of the temporal deformation of the corneal apex. Quantitative analysis allows direct extraction of several deformation parameters, such as apex indentation across time, maximal indentation depth, temporal symmetry and peak distance at maximal deformation. The potential of the technique is demonstrated and compared to air-puff imaging with Scheimpflug. Measurements ex vivo were performed on 14 freshly enucleated porcine eyes and five human donor eyes. Measurements in vivo were performed on nine human eyes. Corneal deformation was studied as a function of Intraocular Pressure (IOP, 15-45 mmHg), dehydration, changes in corneal rigidity (produced by UV corneal cross-linking, CXL), and different boundary conditions (sclera, ocular muscles). Geometrical deformation parameters were used as input for inverse finite element simulation to retrieve the corneal dynamic elastic and viscoelastic parameters. Temporal and spatial deformation profiles were very sensitive to the IOP. CXL produced a significant reduction of the cornea indentation (1.41x), and a change in the temporal symmetry of the corneal deformation profile (1.65x), indicating a change in the viscoelastic properties with treatment. Combining air-puff with dynamic imaging and finite element modeling allows characterizing the corneal biomechanics in-vivo.

  5. [Optical quality after 2.2mm microincisional cataract surgery with bimanual I/A in 154 eyes].

    PubMed

    Dot, C; El Chehab, H; Agard, E; Russo, A; Ract-Madoux, G; Dussart, C

    2013-12-01

    A prospective study to analyze the effects of 2.2mm microincisional coaxial phacoemulsification with bimanual irrigation/aspiration on the optical quality of the cornea and whole eye. We compare two groups. Group A: 102 consecutive eyes undergoing this three-incision procedure and implanted with an Alcon® SN60WF IQ aspheric intraocular lens. Astigmatism, corneal and total asphericity, as well as H/B ratio were measured by OPD scann II, Nidek®, Japan, preoperatively (Day 0), 15 days postoperatively (Day 15) and 1 month postoperatively (M1). Group B: 52 eyes with corneal astigmatism greater than 1.25D, undergoing the same procedure but implanted with a Toric IOL (Alcon® Toric IQ SN6AT), followed in the same manner but with additional follow-up at 1 year. Corneal surgically induced astigmatism (SIA) was essentially neutral: 0.065D ± 0.86 at Day 30 in group A, and 0.06D ± 0.34 at 1 month and -0.008D ± 0.4 at 12 months in group B. Corneal topographic astigmatism underwent a mean axis shift of 29.95° ± 27.6 in group A compared to 5.3° ± 3.7 in Group B, and remained stable at 1 year. Corneal asphericity did not change significantly between Day 0 and 30 in either group. H/B ratio increased significantly in both groups, with a gain of 22 % to 24 % after surgery. This three-incision procedure does not degrade the optical quality of the cornea. Postoperative shift in the axis of astigmatism is only an issue in cases of low or asymmetric astigmatism and must be kept in mind for low-power toric IOL implantation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. Beginnings of Astigmatism Understanding and Management in the 19th Century.

    PubMed

    Grzybowski, Andrzej; Kanclerz, Piotr

    2017-11-14

    Within the last 200 years, the perception of astigmatism has evolved from that of an infrequent and peculiar defect of the eye to a distortion almost as common as spherical refractive errors. Most of the significant findings on this condition were made in the 19th century, including the first description by Thomas Young (1773-1829) and the introduction of the treatment methods used today. The purpose of this study was to investigate the milestones in the understanding and management of astigmatism that occurred up to the year 1900. This fascinating history illustrates how knowledge evolves across time, geographical areas, and interdisciplinary boundaries. The first article looking at the use of a cylindrical lens to correct astigmatism was written by George Airy (1801-1892) in 1825. The term "astigmatism" was introduced in by William Whewell (1794-1866) in 1846. Methods for subjective and objective evaluation were subsequently established, including the introduction of a cross cylinder, keratoscope, astigmatic dial, and the development of retinoscopy and ophthalmoscopy. In the last two decades of the 19th century, the first attempt to alter the refraction in astigmatic patients by changing the shape of the cornea was made. It must be noted that diverse challenges were encountered in this field on the way to the development of a treatment, including the technical manufacture of a lens, the precise measurement of the refractive error, and understanding the optical properties of the eye. The importance of the 19th century was that interdisciplinary cooperation, such as that seen in this study, between physicists and astronomers, and mathematicians and physicians, led to the development of comprehensive knowledge on astigmatism.

  7. Zernike expansion coefficients: rescaling and decentring for different pupils and evaluation of corneal aberrations

    NASA Astrophysics Data System (ADS)

    Comastri, Silvia A.; Perez, Liliana I.; Pérez, Gervasio D.; Martin, Gabriel; Bastida, Karina

    2007-03-01

    An analytical method to convert the set of Zernike coefficients that fits the wavefront aberration for a pupil into another corresponding to a contracted and horizontally translated pupil is proposed. The underlying selection rules are provided and the resulting conversion formulae for a seventh-order expansion are given. These formulae are applied to calculate corneal aberrations referred to a given pupil centre in terms of those referred to the keratometric vertex supplied by the SN CT1000 topographer. Four typical cases are considered: a sphere and three eyes—normal, keratoconic and post-LASIK. When the pupil centre is fixed and the pupil diameter decreases from 6 mm to the photopic natural one, leaving aside piston, tilt and defocus, the difference between the root mean square wavefront error computed with the formulae and the topographer is less than 0.04 µm. When the pupil diameter is kept equal to the natural one and the pupil centre is displaced, coefficients vary according to the eye. For a 0.3 mm pupil shift, the variation of coma is at most 0.35 µm and that of spherical aberration 0.01 µm.

  8. Safety, efficacy, and predictability of laser in situ keratomileusis to correct myopia or myopic astigmatism with a 750 Hz scanning-spot laser system.

    PubMed

    Tomita, Minoru; Watabe, Miyuki; Yukawa, Satoshi; Nakamura, Nobuo; Nakamura, Tadayuki; Magnago, Thomas

    2014-02-01

    To evaluate the clinical outcomes of laser in situ keratomileusis (LASIK) to correct myopia or myopic astigmatism using the Amaris 750S 750 Hz excimer laser. Private LASIK center, Tokyo, Japan. Case series. Patients with myopia or myopic astigmatism (spherical equivalent -0.50 to -11.63 diopters [D]), a corrected distance visual acuity (CDVA) of 20/20 or better, and an estimated residual bed thickness of 300 μm or more had LASIK using the aspheric aberration-free ablation profile of the 750 Hz scanning-spot laser and the Femto LDV Crystal Line femtosecond laser for flap creation. Study parameters included uncorrected distance visual acuity (UDVA), CDVA, manifest refraction, astigmatism, and higher-order aberrations (HOAs). The study included 1280 eyes (685 patients). At 3 months, 96.6% of eyes had a UDVA of 20/20 or better and 99.1% had 20/32 or better; 94.1% of eyes were within ± 0.50 D of the intended correction and 98.9% were within ± 1.00 D; 89.7% of eyes had no residual cylinder and 96.0% had a postoperative astigmatism of less than 0.50 D. All eyes had a postoperative CDVA of 20/20 or better. The HOAs increased postoperatively (P<.001), with mean total postoperative corneal and ocular HOAs of 0.66 μm ± 0.20 (SD) and 0.56 ± 0.23 μm, respectively. The efficacy index and safety index were 1.02 and 1.06, respectively. Laser in situ keratomileusis with the 750 Hz scanning-spot laser was safe, effective, and predictable. No specific clinical side effects that might be associated with a high repetition rate occurred. Mr. Magnago is an employee of Schwind eye-tech-solutions GmbH. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Oregon Elks Children's Eye Clinic vision screening results for astigmatism.

    PubMed

    Vaughan, Joannah; Dale, Talitha; Herrera, Daniel; Karr, Daniel

    2018-04-19

    In the Elks Preschool Vision Screening program, which uses the plusoptiX S12 to screen children 36-60 months of age, the most common reason for over-referral, using the 1.50 D referral criterion, was found to be astigmatism. The goal of this study was to compare the accuracy of the 2.25 D referral criterion for astigmatism to the 1.50 D referral criterion using screening data from 2013-2014. Vision screenings were conducted on Head Start children 36-72 months of age by Head Start teachers and Elks Preschool Vision Screening staff using the plusoptiX S12. Data on 4,194 vision screenings in 2014 and 4,077 in 2013 were analyzed. Area under the curve (AUC) and receiver operating characteristic curve (ROC) analysis were performed to determine the optimal referral criteria. A t test and scatterplot analysis were performed to compare how many children required treatment using the different criteria. The medical records of 136 (2.25 D) and 117 children (1.50 D) who were referred by the plusoptiX screening for potential astigmatism and received dilated eye examinations from their local eye doctors were reviewed retrospectively. Mean subject age was 4 years. Treatment for astigmatism was prescribed to 116 of 136 using the 2.25 D setting compared to 60 of 117 using the 1.50 D setting. In 2013 the program used the 1.50 D setting for astigmatism. Changing the astigmatism setting to 2.25 D; , 85% of referrals required treatment, reducing false positives by 34%. Copyright © 2018. Published by Elsevier Inc.

  10. Computer-Assisted Eye Examination: Background and Prospects.

    DTIC Science & Technology

    1982-05-01

    ipa crossed cylinders. 26, astigmatic charts, kerato- city if numbers. 7. facility. 8-14. efflcac. and meter. corneal astigmatism . lenticular ...Physiological optics, 20; Assessment of visual acuity, 21; Beginnings of subjective refraction, 23; Astigmatism , 24; The subjective optometer, 27; The...to correct astigmatism . Frequently included in the sub- jective examination are tests to determine eye motility and balance (heterophoria and duction

  11. Global prevalence and economic and humanistic burden of astigmatism in cataract patients: a systematic literature review.

    PubMed

    Anderson, David F; Dhariwal, Mukesh; Bouchet, Christine; Keith, Michael S

    2018-01-01

    To systematically review the published evidence on the prevalence and economic and humanistic burden of astigmatism in cataract patients. For this systematic literature review, the Medline, PubMed, Embase, and Cochrane databases were searched from 1996 to September 2015 for available scientific literature that met the inclusion criteria. Studies published in the English language reporting prevalence and humanistic and economic burden in patients diagnosed with cataract and astigmatism were included. Of 3,649 papers reviewed, 31 studies from 32 publications met the inclusion criteria of this review. Preexisting astigmatism ≥1 D was present in up to 47% of cataract eyes. The cost burden of residual uncorrected astigmatism after cataract surgery was driven by the cost of spectacles, which was estimated to range from $2,151 to $3,440 in the US and $1,786 to $4,629 in Europe over a lifetime. In cataract patients, both preexisting and postoperative residual astigmatism were associated with poor vision-related patient satisfaction and quality of life, as well as higher spectacle burden. Astigmatism correction during cataract surgery appears to improve visual outcomes and results in overall lifetime cost savings compared to astigmatism correction with postoperative vision correction. There is a high prevalence of preexisting astigmatism in cataract patients. Although published data are limited, both preoperative astigmatism and postoperative residual astigmatism affect visual function and vision-related quality of life, resulting in increased humanistic burden. Suboptimal correction of astigmatism during cataract surgery drives the continuous need for vision correction with spectacles in the postoperative period. Patients must bear the out-of-pocket expenses, since payers often do not reimburse the cost of spectacles. Greater access to astigmatism correction during cataract surgery could improve visual outcomes and quality of life in patients. More research is required

  12. Transformation of the optical vortex dipole by an astigmatic lens

    NASA Astrophysics Data System (ADS)

    Yan, Hongwei; Lü, Baida

    2009-06-01

    The transformation of the optical vortex dipole (OVD) by an astigmatic lens is studied. The explicit propagation expression of the OVD nested in a Gaussian beam is derived and used to analytically determine the position of the OVD after the passage through the astigmatic lens. The transformation by an aberration-free lens is treated as a special case. It is shown that, depending on the propagation distance, waist width, off-axis distance and astigmatic coefficient, the motion, annihilation and revival of the OVD and the inversion of the topological charge may take place. Specifically, the creation of two OVDs may appear under certain conditions. The results are illustrated by numerical examples.

  13. Astigmatism Progression in the Early Treatment for Retinopathy of Prematurity Study to 6 years of age

    PubMed Central

    Davitt, Bradley V.; Quinn, Graham E.; Wallace, David K.; Dobson, Velma; Hardy, Robert J.; Tung, Betty; Lai, Dejian; Good, William V.

    2011-01-01

    Purpose To examine the prevalence of astigmatism (≥1.00 diopter (D)) and high astigmatism (≥2.00 D) from 6 months post term due date to 6 years postnatal, in preterm children with birth weight ≤ 1251g who developed high-risk prethreshold retinopathy of prematurity (ROP) and participated in the Early Treatment for ROP (ETROP) Study. Design Observational Cohort Study Participants 401 infants who developed high-risk prethreshold ROP in one or both eyes and were randomized to early treatment (ET) versus conventional management (CM). Refractive error was measured by cycloplegic retinoscopy. Eyes were excluded if they received additional retinal, glaucoma, or cataract surgery. Intervention Eyes were randomized to receive laser photocoagulation at high-risk prethreshold ROP or to receive treatment only if threshold ROP developed. Main Outcome Measures Astigmatism and high astigmatism at each study visit. Results For both ET and CM eyes, there was a consistent increase in prevalence of astigmatism over time, increasing from 42% at 4 years to 52% by 6 years for the group of ET eyes and from 47% to 54% in the CM eyes. There was no statistically significant difference between the slopes (rate of change per month) of the ET and CM eyes for both astigmatism and high astigmatism. (P=0.75) Conclusions By 6 years of age, over 50% of eyes with high-risk prethreshold ROP developed astigmatism ≥ 1.00 D, and nearly 25% of such eyes had high astigmatism (≥ 2.00 D). Presence of astigmatism was not influenced by timing of treatment, zone of acute-phase ROP, or presence of plus disease. However, there was a trend toward higher prevalence of astigmatism and high astigmatism in eyes with ROP residua. Most astigmatism was with-the-rule (75º –105º). More eyes with Type 2 than Type 1 had astigmatism by 6 years. These findings reinforce the need for follow-up eye examinations through early grade school years in infants with high risk prethreshold ROP. PMID:21872933

  14. Astigmatism corrected common path probe for optical coherence tomography.

    PubMed

    Singh, Kanwarpal; Yamada, Daisuke; Tearney, Guillermo

    2017-03-01

    Optical coherence tomography (OCT) catheters for intraluminal imaging are subject to various artifacts due to reference-sample arm dispersion imbalances and sample arm beam astigmatism. The goal of this work was to develop a probe that minimizes such artifacts. Our probe was fabricated using a single mode fiber at the tip of which a glass spacer and graded index objective lens were spliced to achieve the desired focal distance. The signal was reflected using a curved reflector to correct for astigmatism caused by the thin, protective, transparent sheath that surrounds the optics. The probe design was optimized using Zemax, a commercially available optical design software. Common path interferometric operation was achieved using Fresnel reflection from the tip of the focusing graded index objective lens. The performance of the probe was tested using a custom designed spectrometer-based OCT system. The probe achieved an axial resolution of 15.6 μm in air, a lateral resolution 33 μm, and a sensitivity of 103 dB. A scattering tissue phantom was imaged to test the performance of the probe for astigmatism correction. Images of the phantom confirmed that this common-path, astigmatism-corrected OCT imaging probe had minimal artifacts in the axial, and lateral dimensions. In this work, we developed an astigmatism-corrected, common path probe that minimizes artifacts associated with standard OCT probes. This design may be useful for OCT applications that require high axial and lateral resolutions. Lasers Surg. Med. 49:312-318, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Comparing aspheric ablation profile with standard corneal ablation for correction of myopia and myopic astigmatism, a contralateral eye study.

    PubMed

    Ghoreishi, Mohammad; Naderi Beni, Afsaneh; Naderi Beni, Zahra; Zandi, Alireza; Kianersi, Farzan

    2017-12-01

    The purpose of this study is to compare visual outcomes of myopic refractive surgery, using tissue saving (TS), a standard ablation profile by a Technolas 217z100, and aberration smart ablation (ASA), an aspheric algorithm by a MEL 80 excimer laser in two eyes of one patient. In this prospective interventional paired-eye controlled study, a total of 100 eyes of 50 participants with myopia with or without astigmatism underwent thin-flap Femto-LASIK, using a Femto LDV femtosecond laser (Ziemer Ophthalmic Systems AG, Port, Switzerland). For each patient, one eye was randomly treated with tissue-saving algorithm (TS group) by the Technolas 217z100 excimer laser and the other eye was treated with optimized smart ablation profile (ASA group) by the MEL 80 excimer laser. Outcome measures were uncorrected distance visual acuities (UDVAs), corrected distance visual acuities (CDVAs), manifest refraction, higher-order aberrations (HOAs), contrast sensitivity, and patient satisfaction 12 months after surgery. At 12 months postoperative, "45 subjects returned with mean" UDVA was - 0.02 ± 0.08 Logarithm of mean angle of resolution (LogMAR) for TS group and - 0.02 ± 0.09 LogMAR for ASA group (P = 0.91). Of the TS eyes, 42/45 (93.3%) and 32/45 (71.1%) were within ± 0.5 D and ± 0.25 D of target refraction, respectively, and of the ASA eyes, 41/45 (91.1%) and 30/45 (66.6%) were within ± 0.5 D and ± 0.25 D of target refraction, respectively. No statistically significant differences were observed between groups in HOAs changes and contrast sensitivity function. Aspheric and non-aspheric LASIKs using the two different excimer lasers provide similar results in myopic and myopic astigmatism patients.

  16. Collagen Cross-Linking Using Riboflavin and Ultraviolet-A for Corneal Thinning Disorders

    PubMed Central

    Pron, G; Ieraci, L; Kaulback, K

    2011-01-01

    predictable, stable, adjustable and durable? Effectiveness - Refractive Outcomes: What impact does remodeling have on refractive outcomes? Effectiveness - Visual Quality (Symptoms): What impact does corneal cross-linking have on vision quality such as contrast vision, and decreased visual symptoms (halos, fluctuating vision)? Effectiveness - Contact lens tolerance: To what extent does contact lens intolerance improve after corneal cross-linking? Vision-Related QOL: What is the impact of corneal cross-linking on functional visual rehabilitation and quality of life? Patient satisfaction: Are patients satisfied with their vision following the procedure? Disease Process: What impact does corneal cross-linking have on the underling corneal thinning disease process? Does corneal cross-linking delay or defer the need for a corneal transplant? What is the comparative safety and effectiveness of corneal cross-linking compared with other minimally invasive treatments for corneal ectasia such as intrastromal corneal rings? Clinical Need: Target Population and Condition Corneal ectasia (thinning) disorders represent a range of disorders involving either primary disease conditions, such as keratoconus (KC) and pellucid marginal corneal degeneration, or secondary iatrogenic conditions, such as corneal thinning occurring after laser in situ keratomileusis (LASIK) refractive surgery. Corneal thinning is a disease that occurs when the normally round dome-shaped cornea progressively thins causing a cone-like bulge or forward protrusion in response to the normal pressure of the eye. The thinning occurs primarily in the stroma layers and is believed to be a breakdown in the collagen process. This bulging can lead to irregular astigmatism or shape of the cornea. Because the anterior part of the cornea is responsible for most of the focusing of the light on the retina, this can then result in loss of visual acuity. The reduced visual acuity can make even simple daily tasks, such as driving

  17. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study.

    PubMed

    Sekundo, Walter; Kunert, Kathleen S; Blum, Marcus

    2011-03-01

    This 6 month prospective multi-centre study evaluated the feasibility of performing myopic femtosecond lenticule extraction (FLEx) through a small incision using the small incision lenticule extraction (SMILE) procedure. Prospective, non-randomised clinical trial. PARTICIPANTS; Ninety-one eyes of 48 patients with myopia with and without astigmatism completed the final 6 month follow-up. The patients' mean age was 35.3 years. Their preoperative mean spherical equivalent (SE) was −4.75±1.56 D. A refractive lenticule of intrastromal corneal tissue was cut utilising a prototype of the Carl Zeiss Meditec AG VisuMax femtosecond laser system. Simultaneously two opposite small ‘pocket’ incisions were created by the laser system. Thereafter, the lenticule was manually dissected with a spatula and removed through one of incisions using modified McPherson forceps. Uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) after 6 months, objective and manifest refraction as well as slit-lamp examination, side effects and a questionnaire. Six months postoperatively the mean SE was −0.01 D±0.49 D. Most treated eyes (95.6%) were within ±1.0 D, and 80.2% were within ±0.5 D of intended correction. Of the eyes treated, 83.5% had an UCVA of 1.0 (20/20) or better, 53% remained unchanged, 32.3% gained one line, 3.3% gained two lines of BSCVA, 8.8% lost one line and 1.1% lost ≥2 lines of BSCVA. When answering a standardised questionnaire, 93.3% of patients were satisfied with the results obtained and would undergo the procedure again. SMILE is a promising new flapless minimally invasive refractive procedure to correct myopia.

  18. Feedforward operation of a lens setup for large defocus and astigmatism correction

    NASA Astrophysics Data System (ADS)

    Verstraete, Hans R. G. W.; Almasian, MItra; Pozzi, Paolo; Bilderbeek, Rolf; Kalkman, Jeroen; Faber, Dirk J.; Verhaegen, Michel

    2016-04-01

    In this manuscript, we present a lens setup for large defocus and astigmatism correction. A deformable defocus lens and two rotational cylindrical lenses are used to control the defocus and astigmatism. The setup is calibrated using a simple model that allows the calculation of the lens inputs so that a desired defocus and astigmatism are actuated on the eye. The setup is tested by determining the feedforward prediction error, imaging a resolution target, and removing introduced aberrations.

  19. Global prevalence and economic and humanistic burden of astigmatism in cataract patients: a systematic literature review

    PubMed Central

    Anderson, David F; Dhariwal, Mukesh; Bouchet, Christine; Keith, Michael S

    2018-01-01

    Purpose To systematically review the published evidence on the prevalence and economic and humanistic burden of astigmatism in cataract patients. Materials and methods For this systematic literature review, the Medline, PubMed, Embase, and Cochrane databases were searched from 1996 to September 2015 for available scientific literature that met the inclusion criteria. Studies published in the English language reporting prevalence and humanistic and economic burden in patients diagnosed with cataract and astigmatism were included. Results Of 3,649 papers reviewed, 31 studies from 32 publications met the inclusion criteria of this review. Preexisting astigmatism ≥1 D was present in up to 47% of cataract eyes. The cost burden of residual uncorrected astigmatism after cataract surgery was driven by the cost of spectacles, which was estimated to range from $2,151 to $3,440 in the US and $1,786 to $4,629 in Europe over a lifetime. In cataract patients, both preexisting and postoperative residual astigmatism were associated with poor vision-related patient satisfaction and quality of life, as well as higher spectacle burden. Astigmatism correction during cataract surgery appears to improve visual outcomes and results in overall lifetime cost savings compared to astigmatism correction with postoperative vision correction. Conclusion There is a high prevalence of preexisting astigmatism in cataract patients. Although published data are limited, both preoperative astigmatism and postoperative residual astigmatism affect visual function and vision-related quality of life, resulting in increased humanistic burden. Suboptimal correction of astigmatism during cataract surgery drives the continuous need for vision correction with spectacles in the postoperative period. Patients must bear the out-of-pocket expenses, since payers often do not reimburse the cost of spectacles. Greater access to astigmatism correction during cataract surgery could improve visual outcomes and quality

  20. A simple method for astigmatic compensation of folded resonator without Brewster window.

    PubMed

    Qiao, Wen; Xiaojun, Zhang; Yonggang, Wang; Liqun, Sun; Hanben, Niu

    2014-02-10

    A folded resonator requires an oblique angle of incidence on the folded curved mirror, which introduces astigmatic distortions that limit the performance of the lasers. We present a simple method to compensate the astigmatism of folded resonator without Brewster windows for the first time to the best of our knowledge. Based on the theory of the propagation and transformation of Gaussian beams, the method is both effective and reliable. Theoretical results show that the folded resonator can be compensated astigmatism completely when the following two conditions are fulfilled. Firstly, when the Gaussian beam with a determined size beam waist is obliquely incident on an off-axis concave mirror, two new Gaussian beam respectively in the tangential and sagittal planes are formed. Another off-axis concave mirror is located at another intersection point of the two new Gaussian beams. Secondly, adjusting the incident angle of the second concave mirror or its focal length can make the above two Gaussian beam coincide in the image plane of the second concave mirror, which compensates the astigmatic aberration completely. A side-pumped continues-wave (CW) passively mode locked Nd:YAG laser was taken as an example of the astigmatically compensated folded resonators. The experimental results show good agreement with the theoretical predictions. This method can be used effectively to design astigmatically compensated cavities resonator of high-performance lasers.

  1. Astigmatism and Refractive Outcome After Late In-The-Bag Intraocular Lens Dislocation Surgery: A Randomized Clinical Trial.

    PubMed

    Kristianslund, Olav; Østern, Atle Einar; Drolsum, Liv

    2017-09-01

    To compare surgically induced astigmatism (SIA) and refractive outcomes between two operation methods for late in-the-bag IOL dislocation. In this prospective, randomized, parallel-group clinical trial, 104 patients (eyes) were assigned to IOL repositioning by scleral suturing 1.5- to 2-mm posterior to limbus (n = 54) or IOL exchange with a retropupillar iris-claw IOL using a 5.5-mm scleral pocket incision (n = 50). The SIA was determined by vector analysis through conversion of corneal cylinders to Cartesian coordinates, and is presented as magnitude in diopters @ direction in degrees (D @ °). Follow-up was 6 months. The SIA was 0.24 D @ 8° for IOL repositioning and 0.65 D @ 171° for IOL exchange, which was a nonsignificant group difference (X coordinate: P = 0.08; Y coordinate: P = 0.16). Mean SIA magnitude was 0.60 ± 0.50 D and 1.12 ± 0.85 D, respectively (P < 0.001). Mean postoperative spherical equivalent was -1.6 ± 1.6 D after IOL repositioning and -0.5 ± 1.0 D after IOL exchange (P < 0.001). For IOL repositioning, this represented a mean myopic shift of -0.7 ± 1.1 D compared with before the IOL dislocation (P < 0.001). For IOL exchange, it was within ±1 D of target refraction in 83% of the patients. Surgically induced astigmatism was modest in both operation groups, albeit with a tendency of being more pronounced for IOL exchange. Repositioning surgery led to a myopic shift, whereas exchange surgery provided good refractive predictability.

  2. Astigmatism in the Early Treatment for Retinopathy of Prematurity Study: findings to 3 years of age

    PubMed Central

    Davitt, Bradley V.; Dobson, Velma; Quinn, Graham E.; Hardy, Robert J.; Tung, Betty; Good, William V.

    2009-01-01

    Purpose To examine the prevalence of astigmatism (≥ 1.00 diopter (D)) and high astigmatism (≥ 2.00 D) at 6 and 9 months post-term and 2 and 3 years postnatal, in preterm children with birth weight < 1251g who developed high-risk prethreshold retinopathy of prematurity (ROP) and participated in the Early Treatment for ROP (ETROP) Study. Design Randomized controlled clinical trial Participants 401 infants who developed prethreshold ROP in one or both eyes and were randomized after they were determined to have a high risk (≥ 15%) of poor structural outcome without treatment, using the RM-ROP2 risk management program. Refractive error was measured by cycloplegic retinoscopy. Eyes with additional retinal, glaucoma, or cataract surgery were excluded. Intervention Eyes were randomized to receive laser photocoagulation at high-risk prethreshold ROP (early treated (ET)) or to be conventionally managed (CM), receiving treatment only if threshold ROP developed. Main Outcome Measures Astigmatism and high astigmatism at each visit. Astigmatism was classified as “with-the rule” (75° – 105° (WTR)), “against-the-rule” (0° – 15° and 165° – 180° (ATR), or “oblique” (16° – 74° and 106° – 164° (OBL)). Results The prevalence of astigmatism in ET and CM eyes was similar at each test age. For both groups, there was an increase in prevalence of astigmatism from approximately 32% at 6 months to approximately 42% by 3 years, mostly occurring between 6 and 9 months. Among eyes that could be refracted, astigmatism was not influenced by zone of acute-phase ROP, presence of plus disease, or retinal residua of ROP. Eyes with astigmatism and high astigmatism most often had WTR astigmatism. Conclusions By age 3 years, nearly 43% of eyes treated at high-risk prethreshold ROP developed astigmatism ≥ 1.00 D and nearly 20% had astigmatism ≥ 2.00 D. Presence of astigmatism was not influenced by timing of treatment of acute-phase ROP, characteristics of acute

  3. Quasi-Bessel beams from asymmetric and astigmatic illumination sources.

    PubMed

    Müller, Angelina; Wapler, Matthias C; Schwarz, Ulrich T; Reisacher, Markus; Holc, Katarzyna; Ambacher, Oliver; Wallrabe, Ulrike

    2016-07-25

    We study the spatial intensity distribution and the self-reconstruction of quasi-Bessel beams produced from refractive axicon lenses with edge emitting laser diodes as asymmetric and astigmatic illumination sources. Comparing these to a symmetric mono-mode fiber source, we find that the asymmetry results in a transition of a quasi-Bessel beam into a bow-tie shaped pattern and eventually to a line shaped profile at a larger distance along the optical axis. Furthermore, we analytically estimate and discuss the effects of astigmatism, substrate modes and non-perfect axicons. We find a good agreement between experiment, simulation and analytic considerations. Results include the derivation of a maximal axicon angle related to astigmatism of the illuminating beam, impact of laser diode beam profile imperfections like substrate modes and a longitudinal oscillation of the core intensity and radius caused by a rounded axicon tip.

  4. Method for Expressing Clinical and Statistical Significance of Ocular and Corneal Wavefront Error Aberrations

    PubMed Central

    Smolek, Michael K.

    2011-01-01

    Purpose The significance of ocular or corneal aberrations may be subject to misinterpretation whenever eyes with different pupil sizes or the application of different Zernike expansion orders are compared. A method is shown that uses simple mathematical interpolation techniques based on normal data to rapidly determine the clinical significance of aberrations, without concern for pupil and expansion order. Methods Corneal topography (Tomey, Inc.; Nagoya, Japan) from 30 normal corneas was collected and the corneal wavefront error analyzed by Zernike polynomial decomposition into specific aberration types for pupil diameters of 3, 5, 7, and 10 mm and Zernike expansion orders of 6, 8, 10 and 12. Using this 4×4 matrix of pupil sizes and fitting orders, best-fitting 3-dimensional functions were determined for the mean and standard deviation of the RMS error for specific aberrations. The functions were encoded into software to determine the significance of data acquired from non-normal cases. Results The best-fitting functions for 6 types of aberrations were determined: defocus, astigmatism, prism, coma, spherical aberration, and all higher-order aberrations. A clinical screening method of color-coding the significance of aberrations in normal, postoperative LASIK, and keratoconus cases having different pupil sizes and different expansion orders is demonstrated. Conclusions A method to calibrate wavefront aberrometry devices by using a standard sample of normal cases was devised. This method could be potentially useful in clinical studies involving patients with uncontrolled pupil sizes or in studies that compare data from aberrometers that use different Zernike fitting-order algorithms. PMID:22157570

  5. Comparison of exact pupil astigmatism conditions with Seidel approximations

    NASA Astrophysics Data System (ADS)

    Zhao, Chunyu; Burge, James H.

    2002-12-01

    The aberrations of axisymmetric imaging systems can be calculated to third order by use of the Seidel formulas. The Coddington equations give aberrations that have quadratic dependence on the pupil, for all field points. The pupil astigmatism conditions were recently developed to predict and control aberrations that have quadratic field dependence and arbitrary pupil dependence. We investigate the relationship between the exact pupil astigmatism conditions and the classical Seidel treatment of pupil aberrations.

  6. Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens.

    PubMed

    Hayashi, Ken; Manabe, Shin-Ichi; Yoshida, Motoaki; Hayashi, Hideyuki

    2010-08-01

    To examine the effect of astigmatism on visual acuity at various distances in eyes with a diffractive multifocal intraocular lens (IOL). Hayashi Eye Hospital, Fukuoka, Japan. In this study, eyes had implantation of a diffractive multifocal IOL with a +3.00 diopter (D) addition (add) (AcrySof ReSTOR SN6AD1), a diffractive multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), or a monofocal IOL (AcrySof SN60WF). Astigmatism was simulated by adding cylindrical lenses of various diopters (0.00, 0.50, 1.00, 1.50, 2.00), after which distance-corrected acuity was measured at various distances. At most distances, the mean visual acuity in the multifocal IOL groups decreased in proportion to the added astigmatism. With astigmatism of 0.00 D and 0.50 D, distance-corrected near visual acuity (DCNVA) in the +4.00 D group and distance-corrected intermediate visual acuity (DCIVA) and DCNVA in the +3.00 D group were significantly better than in the monofocal group; the corrected distance visual acuity (CDVA) was similar. The DCNVA with astigmatism of 1.00 D was better in 2 multifocal groups; however, with astigmatism of 1.50 D and 2.00 D, the CDVA and DCIVA at 0.5m in the multifocal groups were significantly worse than in the monofocal group, although the DCNVA was similar. With astigmatism of 1.00 D or greater, the mean CDVA and DCNVA in the multifocal groups reached useful levels (20/40). The presence of astigmatism in eyes with a diffractive multifocal IOL compromised all distance visual acuities, suggesting the need to correct astigmatism of greater than 1.00 D. No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Accuracy and validity of IK4 handheld video keratometer measurements in children

    PubMed Central

    Harvey, Erin M.; Miller, Joseph M.; Schwiegerling, Jim; Clifford-Donaldson, Candice E.; Green, Tina K.; Messer, Dawn H.; Dobson, Velma

    2011-01-01

    The Infant Keratometer (IK4) is a custom handheld instrument that was designed specifically to allow measurement of corneal astigmatism in infants as young as 6 months of age. In this study, accuracy of IK4 measurements using standard toric surfaces was within 0.25 D. Validity measurements obtained in 860 children aged 3–7 years demonstrated slightly higher astigmatism measurements in the IK4 than in the Retinomax K+. Measurement success was 98% using the IK4. The IK4 may prove to be clinically useful for screening children as young as 3 years of age at high risk for corneal astigmatism. PMID:21907130

  8. A comparison of interocular differences in patients with pigment dispersion syndrome.

    PubMed

    Yip, Leonard W; Sothornwit, Nisa; Berkowitz, Jonathan; Mikelberg, Frederick S

    2009-01-01

    Pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG) are characterized by loss of iris pigment because of reverse pupillary block. The loss of iris pigment is manifested as transillumination defects. Differences in ocular anatomy have been found between subjects with PDS and controls. Our study aims to see if differences in interocular anatomic features are also related to differences in the quantity of transillumination defects between eyes. This is an observational case series of 30 eyes of 15 subjects with PDS/PG in at least 1 eye. Patients underwent refraction, exophthalmometry, corneal and anterior chamber analysis by Pentacam, biometry, A-scan, ultrasound biomicroscopy, and anterior segment digital photography. The Pentacam mean central radii of the posterior corneal surface (cornea back Rm), vertical central radius of curvature of the posterior corneal surface (cornea back Rv), and keratometric power deviation (influence of the posterior surface of the cornea on refractive power) were statistically different between eyes with greater pigment loss and eyes with lesser pigment loss. Eyes with greater pigment loss had a larger back radius of corneal curvature and a correspondingly numerically smaller keratometric power deviation. Other measurements of ocular anatomy were not statistically significant. A flatter curvature of the posterior corneal surface of the eye is associated with increased pigment loss in PDS and PG. The authors postulate that this could result in a difference in the biomechanical properties of the cornea, increased deformation with blinking, and a pumping action resulting in the reverse pupil block of PDS.

  9. Effect of fronto-orbital advancement on astigmatism in patients with anterior plagiocephaly.

    PubMed

    Song, Hyun Beom; Yang, Hee Kyung; Baek, Rong-Min; Hwang, Jeong-Min; Kim, Namju; Wang, Kyu-Chang; Kim, Sukwha

    2016-10-01

    The purpose of this study was to determine the effect of unilateral fronto-orbital advancement (FOA) or bilateral FOA on ocular aspects of plagiocephaly. A retrospective review of ocular findings in 16 patients with plagiocephaly was performed. Patients were divided into 2 groups: 12 patients who underwent bilateral FOA (bFOA) and 4 patients who underwent unilateral FOA (uFOA), and ocular findings were compared. One-half of patients showed strabismus in both groups, and all had exotropia. Hypertropia was found only on the same side of the plagiocephaly in 17% of the bFOA group and 25% of the uFOA group. One-third of the patients in the bFOA group and one-half of patients in the uFOA group had oblique muscle dysfunction. In terms of astigmatism, the degree of with-the-rule astigmatism on the contralateral side was larger in the bFOA group compared to the uFOA group (p = 0.030). The degree of with-the-rule astigmatism was larger on the contralateral side than the ipsilateral side (p = 0.005) in the bFOA group. Patients with abnormalities in ductions/versions had larger astigmatism on the contralateral side than those without abnormalities in ductions/versions. In conclusion, bilateral FOA could induce unwanted outcomes of larger astigmatism on the contralateral side. Astigmatism should be carefully evaluated after bilateral FOA. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Comparison of Visian toric collamer lens and toric acrylic intraocular lens implantation for the treatment of myopia with astigmatism

    PubMed Central

    Ammar, Hatem; Anbar, Mohamed; Abdellah, Marwa M

    2017-01-01

    Purpose To compare the efficacy and outcome of phakic toric implantable collamer lens (TICL) and refractive clear lens extraction with AcrySof Toric intraocular lens (TIOL) implantation for the treatment of myopic astigmatism. Patients and methods This study assessed eyes with myopic astigmatism >−1 D and ≤−4 D with a spherical equivalent >10 D or <10 D if the patients were unsuitable for corneal refractive surgery. These eyes were divided into group A, in which Visian Toric ICL™ Phakic TICL was implanted, and group B, which involved clear lens extraction with implantation of an AcrySof IQ toric SN60T3-9™ IOL. The outcome and complications were evaluated. Results This study enrolled 63 eyes of 38 patients with a follow-up period of at least 6 months. The mean postoperative spherical equivalent was −0.19±0.31 D in group A and −0.21±0.28 D in group B (P=0.69). The mean postoperative cylinder value was −0.46±0.53 D in group A and −0.32±0.41 D in group B (P=0.35). Postoperative cylinder was <1 D in 76.47% and 79.31% of eyes in groups A and B, respectively. The mean endothelial cell count was reduced by 4.32% in group A and by 5.32% in group B (P=0.003). The mean postoperative intraocular pressure increased insignificantly in group A (P=0.22) and reduced significantly in group B (P=0.004). The complication rate was 11.76% in group A and 6.90% in group B. Conclusion Both procedures showed predictable results and good visual results. However, the loss of accommodation and risk of retinal complications in the TIOL group suggest that the use of TICL for myopic astigmatism is a better choice in younger patients. PMID:28096654

  11. Optical analysis for simplified astigmatic correction of non-imaging focusing heliostat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chong, K.K.

    2010-08-15

    In the previous work, non-imaging focusing heliostat that consists of m x n facet mirrors can carry out continuous astigmatic correction during sun-tracking with the use of only (m + n - 2) controllers. For this paper, a simplified astigmatic correction of non-imaging focusing heliostat is proposed for reducing the number of controllers from (m + n - 2) to only two. Furthermore, a detailed optical analysis of the new proposal has been carried out and the simulated result has shown that the two-controller system can perform comparably well in astigmatic correction with a much simpler and more cost effectivemore » design. (author)« less

  12. Corneal Confocal Microscopy Detects Corneal Nerve Damage in Patients Admitted With Acute Ischemic Stroke.

    PubMed

    Khan, Adnan; Akhtar, Naveed; Kamran, Saadat; Ponirakis, Georgios; Petropoulos, Ioannis N; Tunio, Nahel A; Dargham, Soha R; Imam, Yahia; Sartaj, Faheem; Parray, Aijaz; Bourke, Paula; Khan, Rabia; Santos, Mark; Joseph, Sujatha; Shuaib, Ashfaq; Malik, Rayaz A

    2017-11-01

    Corneal confocal microscopy can identify corneal nerve damage in patients with peripheral and central neurodegeneration. However, the use of corneal confocal microscopy in patients presenting with acute ischemic stroke is unknown. One hundred thirty patients (57 without diabetes mellitus [normal glucose tolerance], 32 with impaired glucose tolerance, and 41 with type 2 diabetes mellitus) admitted with acute ischemic stroke, and 28 age-matched healthy control participants underwent corneal confocal microscopy to quantify corneal nerve fiber density, corneal nerve branch density, and corneal nerve fiber length. There was a significant reduction in corneal nerve fiber density, corneal nerve branch density, and corneal nerve fiber length in stroke patients with normal glucose tolerance ( P <0.001, P <0.001, P <0.001), impaired glucose tolerance ( P =0.004, P <0.001, P =0.002), and type 2 diabetes mellitus ( P <0.001, P <0.001, P <0.001) compared with controls. HbA1c and triglycerides correlated with corneal nerve fiber density ( r =-0.187, P =0.03; r =-0.229 P =0.01), corneal nerve fiber length ( r =-0.228, P =0.009; r =-0.285; P =0.001), and corneal nerve branch density ( r =-0.187, P =0.033; r =-0.229, P =0.01). Multiple linear regression showed no independent associations between corneal nerve fiber density, corneal nerve branch density, and corneal nerve fiber length and relevant risk factors for stroke. Corneal confocal microscopy is a rapid noninvasive ophthalmic imaging technique that identifies corneal nerve fiber loss in patients with acute ischemic stroke. © 2017 American Heart Association, Inc.

  13. Removal and Repositioning of Intracorneal Ring Segments: Improving Corneal Topography and Clinical Outcomes in Keratoconus and Ectasia.

    PubMed

    Chan, Kahei; Hersh, Peter S

    2017-02-01

    To evaluate the efficacy of removal and relocation of intracorneal ring segments for improving outcomes in treatment of keratoconus and corneal ectasia. This is a retrospective case series conducted at a cornea and refractive surgery subspecialty practice setting. Patients with previous insertion of 2 intracorneal ring segments underwent surgical removal and repositioning of segments because of unsatisfactory visual and topographic outcomes. The principal outcomes included uncorrected and corrected visual acuities, manifest refraction, topography-derived maximum keratometry (Kmax), inferior-superior topography power difference (I - S), and higher-order aberration profile derived from wavefront analysis. Three patients are presented in this case series. Uncorrected visual acuity improved in all eyes by an average of 2.75 lines. Corrected visual acuity improved in 2 eyes and remained unchanged in 1 eye. Refractive astigmatism decreased in all patients by an average of 2.50 D. Kmax decreased by an average of 1.43 D. All patients had improvement in the I - S value with a mean decrease of 5.13 D. Topography-guided repositioning and/or replacement of corneal ring segments can result in improved topographic, optical, and visual outcomes in patients in whom the initial result is suboptimal. In these cases, a single segment repositioned beneath the cone resulted in an improved outcome. Analysis of corneal topography can guide the surgeon in treatment planning and can suggest patients in whom such an effort will be rewarded with better results.

  14. Aspheric versus wavefront-guided aspheric photorefractive keratectomy in eyes with significant astigmatism.

    PubMed

    Faramarzi, Amir; Moshirfar, Majid; Karimian, Farid; Delfazayebaher, Siamak; Kheiri, Bahareh

    2017-12-01

    To compare the refractive and higher-order aberrations (HOAs) outcomes after photorefractive keratectomy (PRK) in patients with significant astigmatism using aspheric versus wavefront-guided aspheric profiles. Ophthalmic Research Center and Department of Ophthalmology, Shahid Beheshti University of Medical Sciences, Negah Eye Hospital, Tehran, Iran. Prospective randomized case series. One eye of each patient with a refractive astigmatism more than 2.00 diopters (D) randomly received aspheric PRK. In the other eye, wavefront-guided and aspheric treatment was performed using a personalized treatment advanced algorithm. Visual acuity, refractive errors, and HOAs were compared between the 2 groups preoperatively and 12 months postoperatively. The study comprised 32 patients (64 eyes). The mean preoperative refractive astigmatism was -4.07 D ± 1.64 (SD) and -4.02 ± 1.55 D in the aspheric group and wavefront-guided aspheric group, respectively (P = .2). The mean postoperative astigmatism was -0.46 ± 0.37 D and -0.82 ± 0.53 D in the aspheric group and wavefront-guided aspheric group, respectively (P = .02). Postoperatively, the root mean square of total HOAs was significantly increased in both groups. However, compared with wavefront-guided aspheric PRK, aspheric PRK induced fewer HOAs (P = .003). In eyes with high astigmatism, post-PRK residual astigmatism was lower in the aspheric group than in the wavefront-guided aspheric group. The increase in HOAs was significantly higher in the wavefront-guided aspheric group than in the aspheric group. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Astigmatism in Chinese primary school children: prevalence, change, and effect on myopic shift.

    PubMed

    Chan, Shao-En; Kuo, Hsi-Kung; Tsai, Chia-Ling; Wu, Pei-Chang

    2018-05-01

    To study the prevalence, type, and progression of astigmatism in primary school children, and its effect on myopic shift. A prospective study carried out in a primary school in southern Taiwan. The study was performed on a subset of children, one year after initial examination. Refractive error measured by cycloplegic autorefraction was the main study outcome. Astigmatism was recorded as negative cylinder form, and we defined clinical significant astigmatism (CSA) as cylinder refraction -1.0 D or greater. Myopia was defined as a spherical equivalent refraction (SER) of -0.50 D or greater. Three hundred sixty-two children, mean age was 8.97 y/o (SD 1.41; range 7 to 11 y/o) participated in the study. One hundred nineteen (32.9 %) subjects had CSA at the initial screening. The mean cylinder refraction was -0.80 + 0.84 diopters (D) (-5.25 D to 0.00 D), with predominant with rule astigmatism (69.7%). In the 183 children studied longitudinally, the mean cylinder refraction was reduced from -0.74 D to -0.58 D (p< 0.05). The cylinder refraction in the initial CSA group was not associated with SER change (p=0.99) or axial length change (p=0.55). Compared to the initial non-CSA group, the initial CSA group had no significant difference in axial length elongation (p=0.20). The prevalence of astigmatism was not low in the Chinese primary school children and with-the-rule astigmatism was predominant. The astigmatism decreased during the 1 year follow-up. The CSA was not associated with myopia progression (p=0.99).

  16. Ocular biometric characteristics of cataract patients in western China.

    PubMed

    Huang, Qing; Huang, Yongzhi; Luo, Qu; Fan, Wei

    2018-04-17

    We aimed to measure ocular biometric characteristics in older cataract patients from western China. Ocular biometry records were retrospectively analyzed for 6933 patients with cataracts (6933 eyes) at least 50 years old who were treated at West China Hospital of Sichuan University. Partial coherence laser interferometry gave the following population averages: axial length (AL), 24.32 ± 2.42 mm; anterior chamber depth (ACD), 3.08 ± 0.47 mm; keratometric power (K), 44.23 ± 1.66 diopters; and corneal astigmatism (CA), 1.00 ± 0.92 diopters. The percentage of individuals with AL > 26.5 mm was 13.66%, while the percentage with CA > 1.0 diopters was 35.54%. Mean AL and ACD showed a trend of decrease with increasing age (P < 0.001). AL correlated positively with ACD (Spearman coefficient, 0.542) and CA (0.111), but negatively with K (- 0.411) (all P < 0.01). K also correlated negatively with ACD (- 0.078, P < 0.01). These results show, for the first time, that older cataract patients from western China have similar ocular biometric characteristics as other populations. The high prevalence of severe axial myopia warrants further investigation.

  17. Intraoperative corneal thickness measurements during corneal collagen cross-linking with isotonic riboflavin solution without dextran in corneal ectasia.

    PubMed

    Cınar, Yasin; Cingü, Abdullah Kürşat; Sahin, Alparslan; Türkcü, Fatih Mehmet; Yüksel, Harun; Caca, Ihsan

    2014-03-01

    Abstract Objective: To monitor the changes in corneal thickness during the corneal collagen cross-linking procedure by using isotonic riboflavin solution without dextran in ectatic corneal diseases. The corneal thickness measurements were obtained before epithelial removal, after epithelial removal, following the instillation of isotonic riboflavin solution without dextran for 30 min, and after 10 min of ultraviolet A irradiation. Eleven eyes of eleven patients with progressive keratoconus (n = 10) and iatrogenic corneal ectasia (n = 1) were included in this study. The mean thinnest pachymetric measurements were 391.82 ± 30.34 µm (320-434 µm) after de-epithelialization of the cornea, 435 ± 21.17 µm (402-472 µm) following 30 min instillation of isotonic riboflavin solution without dextran and 431.73 ± 20.64 µm (387-461 µm) following 10 min of ultraviolet A irradiation to the cornea. Performing corneal cross-linking procedure with isotonic riboflavin solution without dextran might not induce corneal thinning but a little swelling throughout the procedure.

  18. Analysis of incidence of keratoconus in relatives of patients who underwent corneal transplant due to advanced keratoconus using the Orbscan II topographic graphs

    NASA Astrophysics Data System (ADS)

    López Olazagasti, Estela; Hernández y del Callejo, César E.; Ibarra-Galitzia, Jorge; Ramírez-Zavaleta, Gustavo; Tepichín, Eduardo

    2011-10-01

    Keratoconus is a corneal disease in which the cornea assumes a conical shape due to an irregular alteration of the internal structure of the corneal tissue and sometimes is progressive, especially in young people. Anatomically, the main signs of keratoconus are thinning of the cornea in its central or paracentral region, usually accompanied by an increase in this part of a high irregular astigmatism, with a consequent loss of vision. Its diagnosis requires a thorough study including the family history, a complete ophthalmologic examination and imaging studies. This diagnosis allows classifying the type of keratoconus, which allow determining options of management, with what it is possible to establish a visual prognosis of each eye. One of the indicators that help in the diagnosis of keratoconus is an inherited familiar propensity. The literature reports an incidence of keratoconus of 11%1 in first-degree relatives of patients with keratoconus. Results suggest an ethnic dependence, which implies that the knowledge of the tendency of keratoconus in the Mexican population is important. In this work, we present the preliminary results of the study realized to a group of relatives of patients who underwent corneal transplant by advanced keratoconus using Orbscan II topographic diagnosis, to determine the predisposition to Keratoconus in this group.e

  19. Axis-free correction of astigmatism using bifocal soft contact lenses.

    PubMed

    Leube, Alexander; Kovats, Imre; Wahl, Siegfried; Sickenberger, Wolfgang

    2017-12-01

    Pilot study to investigate the feasibility of an axis-free correction approach of regular astigmatism using soft, bifocal contact lenses (CL). The investigation covers an optical simulation and a pilot study for the assessment of visual performance (over refraction OR, monocular visual acuity VA). The power of the two zones was adjusted according to the power of the astigmatic meridians, individually. Subjective performance was assessed in 30 participants with a mean horizontal cylindrical component of J 0 =- 0.65±1.29 D (cylinder from -0.75 to -4.00 DC). OR and VA were measured directly after fitting the CL, after one hour and after 5days (3FUP). Evaluating the modulation transfer function, CL increased the Strehl ratio by 10% and the transferred spatial frequency was improved from 6.6 cpd to 21.3 cpd. Analysis of Sturm's interval revealed a residual astigmatism of D Ast =0.73 D. OR revealed a statistically significant reduction of spherical error between baseline and all follow up (ΔM=-2.14 D, p<0.001) and between the J 0 from baseline to 3FUP (ΔJ 0 =-0.46 D, p=0.04). Wearing the CL for 5days did not result in a significant difference of VA (ΔVA 3FUP =+0.01 logMAR, p=0.99). Axis-free correction of astigmatism using bifocal CL resulted in reasonable performance based on computer simulation. Participants showed no clinically reduced visual acuity or contrast sensitivity. Further clinical studies are needed to show if this approach provides a good alternative to conventional astigmatic correction. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Enantiomorphism and rule similarity in the astigmatism axes of fellow eyes: A population-based study.

    PubMed

    Hashemi, Hassan; Asharlous, Amir; Yekta, Abbasali; Ostadimoghaddam, Hadi; Mohebi, Masumeh; Aghamirsalim, Mohamadreza; Khabazkhoob, Mehdi

    2018-04-03

    To evaluate the relationship patterns between astigmatism axes of fellow eyes (rule similarity and symmetry) and to determine the prevalence of each pattern in the studied population. This population-based study was conducted in 2015 in Iran. All participants had tests for visual acuity, objective refraction, subjective refraction (if cooperative), and assessment of eye health at the slit-lamp. Axis symmetry was based on two different patterns: direct (equal axes) and mirror (mirror image symmetry) or enantiomorphism. Bilateral astigmatism was classified as isorule if fellow eyes had the same orientation (e.g. both eyes were with-the-rule) and as anisorule if otherwise. Of the total cases of bilateral astigmatism, 80% were isorule, and in the studied population, the prevalence of isorule and anisorule astigmatism was 14.89% and 3.53%, respectively. The prevalence of isorule increased with age (p<0.001). The prevalence of both isorule and anisorule increased at higher degrees of spherical ametropia (p<0.001). Median inter-ocular axis difference was 10° in mirror symmetry and 20° in direct symmetry with no significant difference between two genders (p>0.288). Both symmetry patterns reduced with age (p<0.001). Among cases of bilateral astigmatism, 15.5% and 19.8% had exact direct and mirror symmetry, respectively. Bilateral astigmatism is mainly isorule in the population and anisorule astigmatism is rare. The enantiomorphism is the most common pattern in the population of bilateral astigmatism. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  1. [Design and Realization of Personalized Corneal Analysis Software Based on Corneal Topography System].

    PubMed

    Huang, Xueping; Xie, Zhonghao; Cen, Qin; Zheng, Suilian

    2016-08-01

    As the most important refraction part in the optical system,cornea possesses characteristics which are important parameters in ophthalmology clinical surgery.During the measurement of the cornea in our study,we acquired the corneal data of Orbscan Ⅱ corneal topographer in real time using the Hook technology under Windows,and then took the data into the corneal analysis software.We then further analyzed and calculated the data to obtain individual Q-value of overall corneal 360semi-meridian.The corneal analysis software took Visual C++ 6.0as development environment,used OpenGL graphics technology to draw three-dimensional individual corneal morphological map and the distribution curve of the Q-value,and achieved real-time corneal data query.It could be concluded that the analysis would further extend the function of the corneal topography system,and provide a solid foundation for the further study of automatic screening of corneal diseases.

  2. [Clinical analysis of real-time iris recognition guided LASIK with femtosecond laser flap creation for myopic astigmatism].

    PubMed

    Jie, Li-ming; Wang, Qian; Zheng, Lin

    2013-08-01

    To assess the safety, efficacy, stability and changes in cylindrical degree and axis after real-time iris recognition guided LASIK with femtosecond laser flap creation for the correction of myopic astigmatism. Retrospective case series. This observational case study comprised 136 patients (249 eyes) with myopic astigmatism in a 6-month trial. Patients were divided into 3 groups according to the pre-operative cylindrical degree: Group 1, -0.75 to -1.25 D, 106 eyes;Group 2, -1.50 to -2.25 D, 89 eyes and Group 3, -2.50 to -5.00 D, 54 eyes. They were also grouped by pre-operative astigmatism axis:Group A, with the rule astigmatism (WTRA), 156 eyes; Group B, against the rule astigmatism (ATRA), 64 eyes;Group C, oblique axis astigmatism, 29 eyes. After femtosecond laser flap created, real-time iris recognized excimer ablation was performed. The naked visual acuity, the best-corrected visual acuity, the degree and axis of astigmatism were analyzed and compared at 1, 3 and 6 months postoperatively. Static iris recognition detected that eye cyclotorsional misalignment was 2.37° ± 2.16°, dynamic iris recognition detected that the intraoperative cyclotorsional misalignment range was 0-4.3°. Six months after operation, the naked visual acuity was 0.5 or better in 100% cases. No eye lost ≥ 1 line of best spectacle-corrected visual acuity (BSCVA). Six months after operation, the naked vision of 227 eyes surpassed the BSCVA, and 87 eyes gained 1 line of BSCVA. The degree of astigmatism decreased from (-1.72 ± 0.77) D (pre-operation) to (-0.29 ± 0.25) D (post-operation). Six months after operation, WTRA from 157 eyes (pre-operation) decreased to 43 eyes (post-operation), ATRA from 63 eyes (pre-operation) decreased to 28 eyes (post-operation), oblique astigmatism increased from 29 eyes to 34 eyes and 144 eyes became non-astigmatism. The real-time iris recognition guided LASIK with femtosecond laser flap creation can compensate deviation from eye cyclotorsion, decrease

  3. Nonparaxial wave beams and packets with general astigmatism

    NASA Astrophysics Data System (ADS)

    Kiselev, A. P.; Plachenov, A. B.; Chamorro-Posada, P.

    2012-04-01

    We present exact solutions of the wave equation involving an arbitrary wave form with a phase closely similar to the general astigmatic phase of paraxial wave optics. Special choices of the wave form allow general astigmatic beamlike and pulselike waves with a Gaussian-type unrestricted localization in space and time. These solutions are generalizations of the known Bateman-type waves obtained from the connection existing between beamlike solutions of the paraxial parabolic equation and relatively undistorted wave solutions of the wave equation. As a technical tool, we present a full description of parametrizations of 2×2 symmetric matrices with positive imaginary part, which arise in the theory of Gaussian beams.

  4. Plasma channels during filamentation of a femtosecond laser pulse with wavefront astigmatism in air

    NASA Astrophysics Data System (ADS)

    Dergachev, A. A.; Ionin, A. A.; Kandidov, V. P.; Mokrousova, D. V.; Seleznev, L. V.; Sinitsyn, D. V.; Sunchugasheva, E. S.; Shlenov, S. A.; Shustikova, A. P.

    2014-12-01

    We have demonstrated experimentally and numerically the possibility of controlling parameters of plasma channels formed during filamentation of a femtosecond laser pulse by introducing astigmatism in the laser beam wavefront. It is found that weak astigmatism increases the length of the plasma channel in comparison with the case of aberration-free focusing and that strong astigmatism can cause splitting of the plasma channel into two channels located one after another on the filament axis.

  5. Mechanisms of Optical Regression Following Corneal Laser Refractive Surgery: Epithelial and Stromal Responses

    PubMed Central

    MOSHIRFAR, Majid; DESAUTELS, Jordan D.; WALKER, Brian D.; MURRI, Michael S.; BIRDSONG, Orry C.; HOOPES, Phillip C. Sr

    2018-01-01

    Laser vision correction is a safe and effective method of reducing spectacle dependence. Photorefractive Keratectomy (PRK), Laser In Situ Keratomileusis (LASIK), and Small-Incision Lenticule Extraction (SMILE) can accurately correct myopia, hyperopia, and astigmatism. Although these procedures are nearing optimization in terms of their ability to produce a desired refractive target, the long term cellular responses of the cornea to these procedures can cause patients to regress from the their ideal postoperative refraction. In many cases, refractive regression requires follow up enhancement surgeries, presenting additional risks to patients. Although some risk factors underlying refractive regression have been identified, the exact mechanisms have not been elucidated. It is clear that cellular proliferation events are important mediators of optical regression. This review focused specifically on cellular changes to the corneal epithelium and stroma, which may influence postoperative visual regression following LASIK, PRK, and SMILE procedures. PMID:29644238

  6. Surgical treatment of advanced pellucid marginal degeneration.

    PubMed

    Rasheed, K; Rabinowitz, Y S

    2000-10-01

    To determine the efficacy of simultaneous peripheral crescentic lamellar keratoplasty (LK) and central penetrating keratoplasty (PK) for advanced pellucid marginal degeneration (PMD). Retrospective, noncomparative, interventional case series. Five patients with advanced PMD. Simultaneous peripheral crescentic LK and central PK followed by selective suture removal and astigmatic keratotomy in the postoperative period. These included interval of time required for visual rehabilitation, best spectacle-corrected visual acuity achieved, and amount of corneal astigmatism, as measured by videokeratography. Measuring the change in corneal astigmatism by videokeratography over the subsequent follow-up period after spectacle correction had been prescribed assessed stability of the achieved refraction. Visual acuity results were 20/40 in three eyes, 20/80 in one eye, and 20/400 in one eye. The latter two had decreased acuity from posterior subcapsular cataract formation, which may have been caused by topical steroid use. The time required for visual rehabilitation ranged from 5.13 to 10.93 (mean, 9.92) months, and the amount of corneal astigmatism at the end of this period ranged from 0.3 diopters (D) to 5.3 D. A tendency for an increase in "with the rule astigmatism" after the rehabilitation period was noted. Two patients had elevations of intraocular pressure that responded to reduction in topical steroid dose. The short-term results with this technique are excellent in that it provides early and stable visual rehabilitation in patients with advanced PMD. Low to moderate levels of postkeratoplasty astigmatism were achieved in all the eyes treated. The usual tendency of an increase in "against the rule astigmatism" that occurs when PK alone is done for PMD was eliminated.

  7. Assessment and statistics of surgically induced astigmatism.

    PubMed

    Naeser, Kristian

    2008-05-01

    The aim of the thesis was to develop methods for assessment of surgically induced astigmatism (SIA) in individual eyes, and in groups of eyes. The thesis is based on 12 peer-reviewed publications, published over a period of 16 years. In these publications older and contemporary literature was reviewed(1). A new method (the polar system) for analysis of SIA was developed. Multivariate statistical analysis of refractive data was described(2-4). Clinical validation studies were performed. The description of a cylinder surface with polar values and differential geometry was compared. The main results were: refractive data in the form of sphere, cylinder and axis may define an individual patient or data set, but are unsuited for mathematical and statistical analyses(1). The polar value system converts net astigmatisms to orthonormal components in dioptric space. A polar value is the difference in meridional power between two orthogonal meridians(5,6). Any pair of polar values, separated by an arch of 45 degrees, characterizes a net astigmatism completely(7). The two polar values represent the net curvital and net torsional power over the chosen meridian(8). The spherical component is described by the spherical equivalent power. Several clinical studies demonstrated the efficiency of multivariate statistical analysis of refractive data(4,9-11). Polar values and formal differential geometry describe astigmatic surfaces with similar concepts and mathematical functions(8). Other contemporary methods, such as Long's power matrix, Holladay's and Alpins' methods, Zernike(12) and Fourier analyses(8), are correlated to the polar value system. In conclusion, analysis of SIA should be performed with polar values or other contemporary component systems. The study was supported by Statens Sundhedsvidenskabeligt Forskningsråd, Cykelhandler P. Th. Rasmussen og Hustrus Mindelegat, Hotelejer Carl Larsen og Hustru Nicoline Larsens Mindelegat, Landsforeningen til Vaern om Synet

  8. Laser in situ keratomileusis for high hyperopia with corneal vertex centration and asymmetric offset.

    PubMed

    de Ortueta, Diego; Arba-Mosquera, Sam

    2017-03-10

    To investigate refractive outcomes and induction of corneal higher order aberrations (HOA) in eyes that underwent laser-assisted in situ keratomileusis (LASIK) for high hyperopia correction using an aberration neutral profile with corneal vertex centration and asymmetric offset. A total of 24 consecutive patients (38 eyes) who underwent LASIK by one surgeon using AMARIS 750S excimer laser and a Carriazo-Pendular microkeratome for flap creation were retrospectively analyzed. Eyes targeted for plano and with correction in the maximum hyperopic meridian strictly higher than +4D were included in the retrospective analysis. Patients were reviewed at 1, 3, and 6 months postoperatively. Postoperative monocular corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA), manifest refraction, and corneal wavefront aberrations were compared with respective preoperative metrics. Mean preoperative spherical equivalent and refractive astigmatism was +4.07 ± 0.90 D and 1.37 ± 1.26 D, respectively, reducing to +0.28 ± 0.58D (p<0.0001) and 0.49 ± 0.47 D (p = 0.0001) at the last postoperative visit. Six months postoperatively, 78% of eyes achieved a UDVA of 20/25 or better. No eye lost more than 2 Snellen lines of CDVA at any follow-up. There was a statistically significant induction of vertical trefoil (+0.104 ± 0.299 µm, p<0.05), vertical coma (-0.181 ± 0.463 µm, p<0.01), horizontal coma (+0.198 ± 0.663 µm, p<0.05), spherical aberration (-0.324 ± 0.281 µm, p<0.0001), secondary vertical trefoil (+0.018 ± 0.044 µm, p<0.01), and secondary horizontal coma (+0.026 ± 0.083 µm, p<0.05). Laser-assisted in situ keratomileusis for high hyperopia using corneal vertex centration with asymmetric offset results in significant improvement in refraction and visual acuity although affected by significant induction of some higher order aberrations.

  9. [The relationship between corneal lymphangiogenesis and inflammation index after corneal alkali injury].

    PubMed

    Ling, Shi-qi; Li, Wei-hua; Xu, Jian-gang; Kuang, Wen-hui; Li, Chao-yang

    2010-11-01

    To discuss the relationship between corneal lymphangiogenesis and inflammation index (IF) in alkali burned corneas. Experimental research. Rat corneal hemangiogenesis and lymphangiogenesis were examined by 5'-nase-alkaline phosphatase (5'-NA-ALP) double enzyme-histochemistry and whole mount immunofluorescence at 1 day, 3 days, and 1, 2, 3, 4, 5, 6, 7, 8 weeks after alkaline burns, and the blood vessel counting (BVC) and the lymphatic vessel counting (LVC) were recorded. The state of corneal inflammation was observed under the slit lamp and evaluated by inflammation index (IF) grading at the same time. Then, the association of LVC with IF was examined. In addition, eleven human alkali burned corneas were obtained from 11 patients undergoing corneal transplantation in Zhongshan Ophthalmic Center from January 2005 to June 2008. Corneal lymphangiogenesis was examined by lymphatic vessel endothelial receptor (LYVE-1) immunohistochemistry. The significance of the differences in IF, inflammatory cells counting, burn history, and age between two groups was analyzed by using paired student's t-test. New lymphatic vessels were present in rat alkali burned corneas. Corneal lymphangiogenesis developed 3 days after alkaline burns, reached the top 2 weeks after the injury, then decreased gradually, and disappeared at the end of the 5th week. Corneal lymphatics occurred behind corneal inflammation, but disappeared before corneal inflammation and hemangiogenesis. LVC was strongly and positively correlated with IF (r = 0.572, P < 0.01) after corneal alkaline burns. Among eleven human alkali burned corneas, corneal lymphatic vessels were present in 3 corneas. Compared with the other 8 cases without corneal lymphangiogenesis, the scores of IF was significantly higher (t = 3.28, P < 0.05), the inflammatory cells counting dramatically increased (t = 2.42, P < 0.05), but the age decreased significantly (t = 2.62, P < 0.05). However, the difference in burn history between two groups was

  10. Astigmatic Changes after Horizontal Rectus Muscle Surgery in Intermittent Exotropia

    PubMed Central

    Hong, Seung Woo

    2012-01-01

    Purpose To evaluate the changes of refractive astigmatism after horizontal rectus muscle surgery in intermittent exotropic children. Methods Sixty-nine exotropic patients were retrospectively reviewed. Of those, 35 patients received unilateral lateral rectus recession (BLR group, 35 eyes) and 34 patients received unilateral lateral rectus recession and medial rectus resection (R&R group, 34 eyes). Non-cycloplegic refractions were measured until 6 months postoperatively. Spherical equivalent (SE), J0 and J45 using power vectors were calculated to determine and compare the changes of refractive astigmatism and axis in both groups. Results SE significantly decreased after surgery for the first week and did not changed thereafter in both groups (p = 0.000 and p = 0.018, respectively). In BLR group, J0 showed significant changes at the first week and 1 month after surgery (p = 0.005 and p = 0.016, respectively), but in R&R group, J0 changed significantly between 1 week and 3 months postoperatively (p = 0.023 and p = 0.016, respectively). J45 did not change significantly as time passed in both groups (all p > 0.05). There was no statistically significant difference in the magnitude of changes in SE, J0 and J45 between the two groups after the 6-month follow-up (p = 0.500, p = 0.244 and p = 0.202, respectively). Conclusions Horizontal rectus muscle surgery in intermittent exotropic children tends to induce a statistically significant change in astigmatism in the with-the-rule direction and myopic shift in SE. This astigmatism change seems to occur within the first 3 months after surgery. Thus, astigmatism induced by surgery should be checked and corrected at least 3 months after horizontal strabismus surgery. PMID:23204799

  11. Accelerated corneal crosslinking concurrent with laser in situ keratomileusis.

    PubMed

    Celik, H Ugur; Alagöz, Nese; Yildirim, Yusuf; Agca, Alper; Marshall, John; Demirok, Ahmet; Yilmaz, Omer Faruk

    2012-08-01

    To assess accelerated corneal collagen crosslinking (CXL) applied concurrently with laser in situ keratomileusis (LASIK) in a small group of patients. Beyoglu Eye Research and Training Hospital, Istanbul, Turkey. Prospective pilot interventional case series. In May 2010, patients had LASIK with concurrent accelerated CXL in 1 eye and LASIK only in the fellow eye to treat myopia or myopic astigmatism. The follow-up was 12 months. The attempted correction (spherical equivalent) ranged from -5.00 to -8.50 diopters (D) in the LASIK-CXL group and from -3.00 to -7.25 D in the LASIK-only group. Main outcome measures were manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and the endothelial cell count. Eight eyes of 3 women and 1 man (age 22 to 39 years old) were enrolled. At the 12-month follow-up, the LASIK-CXL group had a UDVA and manifest refraction equal to or better than those in the LASIK-only group. No eye lost 1 or more lines of CDVA at the final visit. The endothelial cell loss in the LASIK-CXL eye was not greater than in the fellow eye. No side effects were associated with either procedure. Laser in situ keratomileusis with accelerated CXL appears to be a promising modality for future applications to prevent corneal ectasia after LASIK treatment. The results in this pilot series suggest that evaluation of a larger study cohort is warranted. Drs. Yilmaz and Marshall are paid consultants to Avedro, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. CMPK1 and RBP3 are associated with corneal curvature in Asian populations.

    PubMed

    Chen, Peng; Miyake, Masahiro; Fan, Qiao; Liao, Jiemin; Yamashiro, Kenji; Ikram, Mohammad K; Chew, Merywn; Vithana, Eranga N; Khor, Chiea-Chuen; Aung, Tin; Tai, E-Shyong; Wong, Tien-Yin; Teo, Yik-Ying; Yoshimura, Nagahisa; Saw, Seang-Mei; Cheng, Ching-Yu

    2014-11-15

    Corneal curvature (CC) measures the steepness of the cornea and is an important parameter for clinically diseases such as astigmatism and myopia. Despite the high heritability of CC, only two associated genes have been discovered to date. We performed a three-stage genome-wide association study meta-analysis in 12 660 Asian individuals. Our Stage 1 was done in multiethnic cohorts comprising 7440 individuals, followed by a Stage 2 replication in 2473 Chinese and Stage 3 in 2747 Japanese. The SNP array genotype data were imputed up to the 1000 Genomes Project Phase 1 cosmopolitan panel. The SNP association with the radii of CC was investigated in the linear regression model with the adjustment of age, gender and principal components. In addition to the known genes, MTOR (also known as FRAP1) and PDGFRA, we discovered two novel genes associated with CC: CMPK1 (rs17103186, P = 3.3 × 10(-12)) and RBP3 (rs11204213 [Val884Met], P = 1.1 × 10(-13)). The missense RBP3 SNP, rs11204213, was also associated with axial length (AL) (P = 4.2 × 10(-6)) and had larger effects on both CC and AL compared with other SNPs. The index SNPs at the four indicated loci explained 1.9% of CC variance across the Stages 1 and 2 cohorts, while 33.8% of CC variance was explained by the genome-wide imputation data. We identified two novel genes influencing CC, which are related to either corneal shape or eye size. This study provides additional insights into genetic architecture of corneal shape. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Safety and efficacy of femtosecond laser-assisted arcuate keratotomy to treat irregular astigmatism after penetrating keratoplasty.

    PubMed

    Fadlallah, Ali; Mehanna, Chadi; Saragoussi, Jean-Jacques; Chelala, Elias; Amari, Belkacem; Legeais, Jean-Marc

    2015-06-01

    To determine the refractive efficacy, predictability, stability, and complication rate of Intralase femtosecond laser-assisted astigmatic keratotomy (AK) for irregular astigmatism after penetrating keratoplasty (PKP). Ophthalmology Department, Hôtel-Dieu, Paris, France. Retrospective case series. Femtosecond laser-assisted AK was performed to treat high irregular astigmatism (>5.0 diopters [D]) after PKP. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, vector analysis, and complications were evaluated. The study evaluated 62 eyes of 57 patients over a mean follow-up of 28 months ± 3.5 (SD). Preoperatively, the mean CDVA was 0.51 ± 0.26 logMAR and the mean UDVA was 0.98 ± 0.24 logMAR; 6 months postoperatively, the mean CDVA and UDVA improved to 0.40 ± 0.22 logMAR and 0.60 ± 0.2 logMAR, respectively (both P < .01). The mean preoperative absolute astigmatism was 7.1 ± 1.72 D; 6 months postoperatively, the mean refractive astigmatism was 2.6 ± 2.4 D (P < .001). The UDVA, CDVA, and astigmatism remained stable up to the end of follow-up. The efficacy index was 0.81 at 6 months and 0.67 at 2 years. There were 2 cases of microperforation, 3 cases of infectious keratitis, 3 graft rejection episodes, and 1 case of endophthalmitis. Overcorrection occurred in 12 eyes. Femtosecond laser-assisted AK was effective in reducing irregular astigmatism after PKP. Predictability of astigmatism correction is variable over time with a decrease in the efficacy index 2 years postoperatively. Refinement of the treatment nomogram for femtosecond laser-assisted AK for high astigmatism after PKP remains a major issue. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Safety and efficacy of simultaneous corneal collagen cross-linking with topography-guided PRK in managing low-grade keratoconus: 1-year follow-up.

    PubMed

    Tuwairqi, Waleed S; Sinjab, Mazen M

    2012-05-01

    To evaluate 1-year visual and topographic outcomes and safety and efficacy of corneal collagen cross-linking (CXL) combined with topography-guided photorefractive keratectomy (TG-PRK) to achieve near emmetropia in eyes with low-grade keratoconus. Twenty-two eyes from 15 patients (11 women, 4 men) were included in a prospective, nonrandomized, noncontrolled clinical study. Mean patient age was 26.6±6.07 years (range: 19 to 40 years). Inclusion criteria were low-grade keratoconus with evidence of progression, transparent cornea, corrected distance visual acuity (CDVA) 0.8 (decimal) or better, corneal thickness >440 μm, and maximum keratometry readings (K-max) <51.00 diopters (D). All patients underwent simultaneous TG-PRK with CXL. Study parameters were uncorrected distance visual acuity, CDVA, manifest refractive error, manifest and topographic (corneal) astigmatism, patient satisfaction, and efficacy and safety of the treatment. Follow-up was 1 year. After 1 year, statistically significant improvement was noted in all study parameters (P<.01). The safety and efficacy indices were 1.6 and 0.4, respectively. Patient satisfaction questionnaire showed that 91% were satisfied, 9% were not completely satisfied but believed they improved, and none were dissatisfied. Corneal topography demonstrated significant improvement in 55%, improvement in 36%, and minor improvement in 9% of cases. No cases progressed as evidenced by keratometry readings. Simultaneous TG-PRK with CXL is an effective and safe treatment with remarkable visual and topographic outcomes in patients with low-grade keratoconus who meet the recommended inclusion criteria. Copyright 2012, SLACK Incorporated.

  15. Comparative Evaluation of the Corneal and Anterior Chamber Parameters Derived From Scheimpflug Imaging in Arab and South Asian Normal Eyes.

    PubMed

    Prakash, Gaurav; Srivastava, Dhruv; Avadhani, Kavitha; Thirumalai, Sandeep M; Choudhuri, Sounak

    2015-11-01

    To evaluate the differences in the normal corneal and anterior segment Scheimpflug parameters in Arab and South Asian eyes. This hospital-based study was performed at a cornea and refractive surgery service in Abu Dhabi. A total of 600 consecutive normal candidates of South Asian (group 1, n = 300) and Arab (group 2, n = 300) origins underwent Scheimpflug imaging (Sirius; Costruzione Strumenti Oftalmici, Italy). One eye was randomly selected for evaluation. The age and sex distributions in both groups were comparable. The pachymetric variables were statistically higher in group 2 (group 2 vs. group 1, 544.3 ± 32.2 μm vs. 535.1 ± 31.4 μm for central corneal thickness, 541.0 ± 32.6 μm vs. 531.9 ± 31.5 μm for minimum corneal thickness, 571.7 ± 43.2 μm vs. 558.1 ± 42.3 μm for apical thickness, and 58.1 ± 4.2 vs. 57.3 ± 4.3 mm³ for the corneal volume; P < 0.05). The anterior chamber volume (group 2 vs. group 1: 166.4 ± 16.4 vs. 161.6 ± 20.5 mm³) and angle (group 2 vs. group 1: 44.6 ± 6.2 vs. 43.5 ± 5.8 degrees) were also higher for group 2 (P < 0.05). Central corneal curvature and apical corneal curvature (apex K) were higher in group 1 (P < 0.05) with comparable astigmatism. The flat keratometry (K), steep K, and apex K were 43.6 ± 2.2 diopters (D), 44.9 ± 1.8 D, and 45.7 ± 1.8 D for group 1, and 43.1 ± 2.2 D, 44.5 ± 2 D, and 45.2 ± 1.9 D for group 2. The effect size (Cohen d) for significant parameters ranged from 0.2 to 0.3. Normal eyes of Arab ethnicity tend to have statistically thicker and flatter corneas and less-crowded anterior segments than those of the South Asian counterparts. These epidemiological differences have a mild to moderate biological effect size (Cohen d), but they should be considered when evaluating these eyes for anterior segment or corneal procedures.

  16. Analysis of astigmatism of gain guided laser with a tapered-stripe geometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mamine, T.; Oda, T.; Yoneyama, O.

    1984-12-01

    The astigmatism of the tapered-stripe (TAPS) laser has been analyzed. Calculating the near-field spot size and the radius of curvature in the tapered-stripe region, the astigmatism is determined by using the expression of D = R/sub e/ (1+(lambdaR/sub e// ..pi..w/sup 2//sub e/)/sup 2/)/sup -1/. In our formalism we assume that the gain profile is parabola and the near-field spot size at the facet is determined by the diffusion length of injected carriers. So far as these assumptions are valid, it is concluded that the amount of astigmatism is reduced with the length of tapered stripe, using the refractive index changemore » due to the band-edge absorption of -10/sup -2/. The fundamental characteristics of the gain guided laser with TAPS structure such as the astigmatism, far-field radiation pattern, and the spontaneous emission factor are shown to be controlled by properly designing the stripe geometry and the thickness of the active layer.« less

  17. Non-toric extended depth of focus contact lenses for astigmatism and presbyopia correction

    NASA Astrophysics Data System (ADS)

    Ben Yaish, Shai; Zlotnik, Alex; Yehezkel, Oren; Lahav-Yacouel, Karen; Belkin, Michael; Zalevsky, Zeev

    2010-02-01

    Purpose: Testing whether the extended depth of focus technology embedded on non-toric contact lenses is a suitable treatment for both astigmatism and presbyopia. Methods: The extended depth of focus pattern consisting of microndepth concentric grooves was engraved on a surface of a mono-focal soft contact lens. These grooves create an interference pattern extending the focus from a point to a length of about 1mm providing a 3.00D extension in the depth of focus. The extension in the depth of focus provides high quality focused imaging capabilities from near through intermediate and up to far ranges. Due to the angular symmetry of the engraved pattern the extension in the depth of focus can also resolve regular as well as irregular astigmatism aberrations. Results: The contact lens was tested on a group of 8 astigmatic and 13 subjects with presbyopia. Average correction of 0.70D for astigmatism and 1.50D for presbyopia was demonstrated. Conclusions: The extended depth of focus technology in a non-toric contact lens corrects simultaneously astigmatism and presbyopia. The proposed solution is based upon interference rather than diffraction effects and thus it is characterized by high energetic efficiency to the retina plane as well as reduced chromatic aberrations.

  18. Corneal cell culture models: a tool to study corneal drug absorption.

    PubMed

    Dey, Surajit

    2011-05-01

    In recent times, there has been an ever increasing demand for ocular drugs to treat sight threatening diseases such as glaucoma, age-related macular degeneration and diabetic retinopathy. As more drugs are developed, there is a great need to test in vitro permeability of these drugs to predict their efficacy and bioavailability in vivo. Corneal cell culture models are the only tool that can predict drug absorption across ocular layers accurately and rapidly. Cell culture studies are also valuable in reducing the number of animals needed for in vivo studies which can increase the cost of the drug developmental process. Currently, rabbit corneal cell culture models are used to predict human corneal absorption due to the difficulty in human corneal studies. More recently, a three dimensional human corneal equivalent has been developed using three different cell types to mimic the human cornea. In the future, human corneal cell culture systems need to be developed to be used as a standardized model for drug permeation.

  19. Component corneal surgery: An update

    PubMed Central

    Maharana, Prafulla K.; Sahay, Pranita; Singhal, Deepali; Garg, Itika; Titiyal, Jeewan S.; Sharma, Namrata

    2017-01-01

    Several decades ago, penetrating keratoplasty was a challenge to corneal surgeons. Constant effort by the corneal surgeon to improve the outcomes as well as utilization of the available resources has led to a revolutionary change in the field of keratoplasty. All these efforts have led to the evolution of techniques that allow a corneal surgeon to disease-specific transplant of individual layers of corneal “so-called component corneal surgery” depending on the layer of cornea affected. This has led to an improvement in corneal graft survival as well as a better utilization of corneal tissues. This article reviews the currently available literature on component corneal surgeries and provides an update on the available techniques. PMID:28820150

  20. 3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea.

    PubMed

    Zhao, Mingtao; Kuo, Anthony N; Izatt, Joseph A

    2010-04-26

    Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

  1. Corneal-shaping electrode

    DOEpatents

    Doss, James D.; Hutson, Richard L.

    1982-01-01

    The disclosure relates to a circulating saline electrode for changing corneal shape in eyes. The electrode comprises a tubular nonconductive electrode housing having an annular expanded base which has a surface substantially matched to a subject corneal surface. A tubular conductive electrode connected to a radiofrequency generating source is disposed within the electrode housing and longitudinally aligned therewith. The electrode has a generally hemispherical head having at least one orifice. Saline solution is circulated through the apparatus and over the cornea to cool the corneal surface while radiofrequency electric current emitted from the electrode flows therefrom through the cornea to a second electrode, on the rear of the head. This current heats the deep corneal stroma and thereby effects corneal reshaping as a biological response to the heat.

  2. Corneal Equilibrium Flux as a Function of Corneal Surface Oxygen Tension.

    PubMed

    Compañ, Vicente; Aguilella-Arzo, Marcel; Weissman, Barry A

    2017-06-01

    Oxygen is essential for aerobic mammalian cell physiology. Oxygen tension (PO2) should reach a minimum at some position within the corneal stroma, and oxygen flux should be zero, by definition, at this point as well. We found the locations and magnitudes of this "corneal equilibrium flux" (xmin) and explored its physiological implications. We used an application of the Monod kinetic model to calculate xmin for normal human cornea as anterior surface PO2 changes from 155 to 20 mmHg. We find that xmin deepens, broadens, and advances from 1.25 μm above the endothelial-aqueous humor surface toward the epithelium (reaching a position 320 μm above the endothelial-aqueous humor surface) as anterior corneal surface PO2 decreases from 155 to 20 mmHg. Our model supports an anterior corneal oxygen flux of 9 μL O2 · cm · h and an epithelial oxygen consumption of approximately 4 μL O2 · cm · h. Only at the highest anterior corneal PO2 does our model predict that oxygen diffuses all the way through the cornea to perhaps reach the anterior chamber. Of most interest, corneal oxygen consumption should be supported down to a corneal surface PO2 of 60 to 80 mmHg but declines below this range. We conclude that the critical oxygen tension for hypoxia induced corneal swelling is more likely this range rather than a fixed value.

  3. Average intensity and spreading of an astigmatic sinh-Gaussian beam with small beam width propagating in atmospheric turbulence

    NASA Astrophysics Data System (ADS)

    Zhu, Jie; Zhu, Kaicheng; Tang, Huiqin; Xia, Hui

    2017-10-01

    Propagation properties of astigmatic sinh-Gaussian beams (ShGBs) with small beam width in turbulent atmosphere are investigated. Based on the extended Huygens-Fresnel integral, analytical formulae for the average intensity and the effective beam size of an astigmatic ShGB are derived in turbulent atmosphere. The average intensity distribution and the spreading properties of an astigmatic ShGB propagating in turbulent atmosphere are numerically demonstrated. The influences of the beam parameters and the structure constant of atmospheric turbulence on the propagation properties of astigmatic ShGBs are also discussed in detail. In particular, for sufficiently small beam width and sinh-part parameter as well as suitable astigmatism, we show that the average intensity pattern converts into a perfect dark-hollow profile from initial two-petal pattern when ShGBs with astigmatic aberration propagate through atmospheric turbulence.

  4. Accuracy of the Welch Allyn Suresight for measurement of magnitude of astigmatism in 3- to 7-year-old children

    PubMed Central

    Harvey, Erin M.; Dobson, Velma; Miller, Joseph M.; Clifford-Donaldson, Candice E.; Green, Tina K.; Messer, Dawn H.; Garvey, Katherine A.

    2009-01-01

    Purpose To evaluate the accuracy of the Welch Allyn SureSight in noncycloplegic measurements of astigmatism as compared to cycloplegic Retinomax K+ autorefractor measurements of astigmatism in children from a Native American population with a high prevalence of high astigmatism. Methods Data are reported for 825 3- to 7-year-old children with no ocular abnormalities. Each child had a Retinomax K+ cycloplegic measurement of right eye astigmatism with a confidence rating ≥8 and 3 attempts to obtain a SureSight measurement on the right eye. Results SureSight measurement success rates did not differ significantly across age or measurement confidence rating (<6 vs ≥6). Ninety-six percent of children had at least 1 measurement (any confidence), and 89% had at least 1 measurement with confidence at the manufacturer's recommended value (≥6). Overall, the SureSight tended to overestimate astigmatism. If the SureSight measurement had any dioptric value (0.00 D to 3.00 D), astigmatism of 2.00 D or less was likely to be present. If the SureSight showed astigmatism beyond the instrument's dioptric range (>3.00 D), Retinomax K+ measurements indicated that >2.00 D of astigmatism was present in 136 of 157 (86.6%). In cooperative children for whom the SureSight would not give a reading, 32 of 34 (94%) had >3.00 D of astigmatism. Conclusions The SureSight does not provide an accurate, quantitative measure of amount of astigmatism. However, it does allow accurate categorization of amount of astigmatism as ≤2.00 D, >2.00 D, or >3.00 D, and it has high measurement success rate in young children. PMID:19840726

  5. Spherotoric bag-in-the-lens intraocular lens: power calculation and predictive misalignment nomogram.

    PubMed

    Gobin, Laure; Tassignon, Marie-José; Mathysen, Danny

    2011-06-01

    To propose a method of calculating the power of the 1-sided posterior chamber toric bag-in-the-lens (BIL) intraocular lens (IOL) and propose a misalignment nomogram to calculate the postoperative rotational misalignment or predict the effect of preoperative existing irregular corneal astigmatism. Antwerp University Hospital, Department of Ophthalmology, Antwerp, Belgium. Cohort study. The new IOL calculation formula uses the steepest corneal meridian and flattest corneal meridian separately (regular spherical IOL formula) followed by a customized A-constant approach based on the changes in the IOL principal plane depending on the spherical and cylindrical powers (thickness) of the IOL. The calculation of the remaining astigmatism (power and axis) in cases of postoperative rotational misalignment resulted in a nomogram that can also be used to predict the degree of tolerance for irregular corneal astigmatism correction at the lenticular plane. The calculation is performed using a worksheet. Because 10 degrees of misalignment would result in 35% refractive inaccuracy, it is the maximum acceptable corneal astigmatic irregularity for correction at the lenticular plane. Calculation of spherocylindrical power is specific to each toric IOL. Because the surgeon must fully understand the optical properties of the toric IOL that is going to be implanted, a comprehensive outline of a new calculation method specific to the toric BIL IOL is proposed. Primary rotational misalignment of the toric BIL IOL can be fine tuned postoperatively. Drs. Gobin and Mathysen have no financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Comparison of femtosecond laser small-incision lenticule extraction and laser-assisted subepithelial keratectomy to correct myopic astigmatism.

    PubMed

    Qian, Yishan; Huang, Jia; Zhou, Xingtao; Wang, Yutung

    2015-11-01

    To compare the efficacy of correcting myopic astigmatism with femtosecond laser small-incision lenticule extraction (SMILE, Carl Zeiss Meditec AG) versus laser-assisted subepithelial keratectomy (LASEK). The study was conducted at the Ophthalmology Department, Eye and ENT Hospital, Shanghai, China. A retrospective, cross-sectional study. This study included patients who underwent small-incision lenticule extraction or LASEK for the correction of myopia and myopic astigmatism. Preoperative and 6-month postoperative astigmatism values were analyzed. The efficacies of the 2 surgeries to correct astigmatism were compared. A total of 180 right eyes of 180 patients (small-incision lenticule extraction: n = 113, LASEK: n = 67) were included. No significant difference was found between the 2 groups in the preoperative astigmatism (small-incision lenticule extraction: 1.16 ± 0.85D, LASEK: 1.16 ± 0.83D, P > .05) or the postoperative astigmatism (small-incision lenticule extraction: 0.35 ± 0.37D; LASEK: 0.31 ± 0.42D, P > .05), determined by manifest refraction. No significant difference was found between the 2 groups in surgically induced astigmatism vector (small-incision lenticule extraction: 1.13 ± 0.83D, LASEK: 1.01 ± 0.65D, P > .05). The correction index was higher for the small-incision lenticule extraction group (1.05 ± 0.53) than for the LASEK group (0.95 ± 0.21, P = .045). The postoperative astigmatism was significantly higher for the small-incision lenticule extraction group when the preoperative astigmatism was 1.0 D or less (small-incision lenticule extraction: 0.26 ± 0.30D, LASEK: 0.12 ± 0.20D, P = .007) and lower for the small-incision lenticule extraction group when the preoperative astigmatism was more than 2.0 D (small-incision lenticule extraction: 0.48 ± 0.37D, LASEK: 0.89 ± 0.46D, P = .002). An adjustment of nomograms for correcting low astigmatism (≤1.0 D) by small-incision lenticule extraction is suggested due to the tendency toward

  7. Recurrent Corneal Erosions in Corneal Dystrophies: a Review of the Pathogenesis, Differential Diagnosis, and Therapy.

    PubMed

    Omari, Amro A; Mian, Shahzad I

    2018-06-01

    Recurrent corneal erosions in corneal dystrophies are visually significant and bothersome to patients. The goal of this article is to review the pathogenesis, differential diagnosis, and management of recurrent corneal erosions in corneal dystrophies. Forty-eight articles and 1 textbook recently published on corneal erosions in corneal dystrophies were reviewed. The findings on the pathogenesis and clinical characteristics of erosions in each dystrophy were summarized. Any contradicting opinions for which the literature was unclear were either omitted or recorded as lacking strong evidence. The epithelial-stromal complex plays an important role in the pathogenesis of erosions in corneal dystrophies. The clinical features of each corneal dystrophy guide their diagnosis and management. A better understanding of the pathogenesis and clinical features of erosions in corneal dystrophies can lead to better clinical outcomes. Georg Thieme Verlag KG Stuttgart · New York.

  8. Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction.

    PubMed

    Garzón, Nuria; Poyales, Francisco; Illarramendi, Igor; Mendicute, Javier; Jáñez, Óscar; Caro, Pedro; López, Alfredo; Argüeso, Francisco

    2017-12-01

    To determine normative corneal densitometry values in relation to age, sex, refractive error, corneal thickness, and keratometry, measured using the Oculus Pentacam system. Three hundred and thirty-eight healthy subjects (185 men; 153 women) with no corneal disease underwent an exhaustive ocular examination. Corneal densitometry was expressed in standardized grayscale units (GSU). The mean corneal densitometry over the total area was 16.46 ± 1.85 GSU. The Pearson correlation coefficient for total densitometry was r = 0.542 (p < 0.001). Statistically significant differences were found between men and women for the total area (p = 0.006), with readings of 16.22 ± 1.54 GSU and 16.60 ± 1.83 GSU, respectively. When the cornea was divided into layers of different depths, a significant correlation was found for all layers and age: r = 0.447 (p < 0.001), r = 0.563 (p < 0.001), and r = 0.520 (p < 0.001) for the anterior, central, and posterior layers, respectively. However, when the cornea was divided into concentric annuli starting from the center of the cornea, densitometry was strongly correlated only with age in the 6-10-mm annulus (p < 0.001). Neither mean keratometry nor spherical equivalent was correlated with corneal densitometry in any zone of the cornea (p > 0.05). This is the first report of normative corneal densitometry values in relation to keratometry, corneal thickness, and spherical equivalent measured with the latest Oculus Pentacam software. Corneal densitometry increases with age, but corneal keratometry and refractive parameters do not affect light scattering in the human cornea.

  9. Ocular refractive and biometric characteristics in patients with tilted disc syndrome.

    PubMed

    Dehghani, Cirous; Nowroozzadeh, Mohammad Hosein; Shankar, Sunita; Razeghinejad, Mohammad Reza

    2010-12-01

    Tilted disc syndrome (TDS) is associated with characteristic ocular findings. The purpose of this study was to evaluate the ocular, refractive, and biometric characteristics in patients with TDS. This case-control study included 41 eyes of 25 patients who had established TDS and 40 eyes of 20 healthy control subjects. All participants underwent a complete ocular examination, including refraction and analysis using Fourier transformation, slit lamp biomicroscopy, pachymetry, keratometry, and ocular biometry. Corneal topography examinations were performed in the syndrome group only. There were no significant differences in spherical equivalent (P = 0.13) and total astigmatism (P = 0.37) between groups. However, mean best spectacle-corrected visual acuity (Log Mar) was significantly worse in TDS patients (P = 0.003). The lenticular astigmatism was greater in the syndrome group, whereas the corneal component was greater in controls (P = 0.059 and P = 0.028, respectively). The measured biometric features were the same in both groups, except for the lens thickness and lens-axial length factor, which were greater in the TDS group (P = 0.007 and P = 0.055, respectively). Clinically significant lenticular astigmatism, more oblique corneal astigmatism, and thicker lenses were characteristic findings in patients with TDS. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.

  10. Ocular dimensions, corneal thickness, and corneal curvature in quarter horses with hereditary equine regional dermal asthenia.

    PubMed

    Badial, Peres R; Cisneros-Àlvarez, Luis Emiliano; Brandão, Cláudia Valéria S; Ranzani, José Joaquim T; Tomaz, Mayana A R V; Machado, Vania M; Borges, Alexandre S

    2015-09-01

    The aim of this study was to compare ocular dimensions, corneal curvature, and corneal thickness between horses affected with hereditary equine regional dermal asthenia (HERDA) and unaffected horses. Five HERDA-affected quarter horses and five healthy control quarter horses were used. Schirmer's tear test, tonometry, and corneal diameter measurements were performed in both eyes of all horses prior to ophthalmologic examinations. Ultrasonic pachymetry was performed to measure the central, temporal, nasal, dorsal, and ventral corneal thicknesses in all horses. B-mode ultrasound scanning was performed on both eyes of each horse to determine the dimensions of the ocular structures and to calculate the corneal curvature. Each corneal region examined in this study was thinner in the affected group compared with the healthy control group. However, significant differences in corneal thickness were only observed for the central and dorsal regions. HERDA-affected horses exhibited significant increases in corneal curvature and corneal diameter compared with unaffected animals. The ophthalmologic examinations revealed mild corneal opacity in one eye of one affected horse and in both eyes of three affected horses. No significant between-group differences were observed for Schirmer's tear test, intraocular pressure, or ocular dimensions. Hereditary equine regional dermal asthenia-affected horses exhibit decreased corneal thickness in several regions of the cornea, increased corneal curvature, increased corneal diameter, and mild corneal opacity. Additional research is required to determine whether the increased corneal curvature significantly impacts the visual accuracy of horses with HERDA. © 2014 American College of Veterinary Ophthalmologists.

  11. Generally astigmatic Gaussian beam representation and optimization using skew rays

    NASA Astrophysics Data System (ADS)

    Colbourne, Paul D.

    2014-12-01

    Methods are presented of using skew rays to optimize a generally astigmatic optical system to obtain the desired Gaussian beam focus and minimize aberrations, and to calculate the propagating generally astigmatic Gaussian beam parameters at any point. The optimization method requires very little computation beyond that of a conventional ray optimization, and requires no explicit calculation of the properties of the propagating Gaussian beam. Unlike previous methods, the calculation of beam parameters does not require matrix calculations or the introduction of non-physical concepts such as imaginary rays.

  12. Corneal fibrosarcoma in a cat.

    PubMed

    Strong, Travis D; Tangeman, Sarah; Ben-Shlomo, Gil; Haynes, Joseph; Allbaugh, Rachel A

    2016-07-01

    To present the clinicopathologic features of a Domestic Short-haired cat with spontaneous, intermediate-grade corneal fibrosarcoma, possibly secondary to chronic corneal irritation associated with a corneal sequestrum. A 12-year-old, spayed female Domestic Short-haired cat was evaluated for a slowly growing, pink, exophytic mass affecting the left cornea. The cat had presented 6 years previously for bilateral brown corneal sequestra, as well as 3 years previously for a small pale growth on the left cornea hypothesized to be an epithelial inclusion cyst and a corneal ulcer affecting the right eye. Incisional biopsy of the corneal mass indicated intermediate-grade corneal fibrosarcoma within the corneal stroma. Owing to the potential for malignant behavior, the left globe was enucleated. Routine systemic staging was performed prior to surgery with no evidence of metastasis. Definitive diagnosis of corneal fibrosarcoma was made through histopathologic examination of the incisional biopsy. There was an elevated mitotic index, indicating an intermediate-grade phenotype. Histopathology of the enucleated globe substantiated the initial findings, and complete tumor resection was confirmed. Subjacent to the corneal fibrosarcoma, there was a region of necrotic tissue suggestive of a corneal sequestrum. Six months after diagnosis and enucleation, the patient remained healthy with no signs of local spread or distant metastasis. To the authors' knowledge, this is the first documented case of a corneal fibrosarcoma in a cat. © 2016 American College of Veterinary Ophthalmologists.

  13. Nonlocal conservation laws of the constant astigmatism equation

    NASA Astrophysics Data System (ADS)

    Hlaváč, Adam; Marvan, Michal

    2017-03-01

    For the constant astigmatism equation, we construct a system of nonlocal conservation laws (an abelian covering) closed under the reciprocal transformations. The corresponding potentials are functionally independent modulo a Wronskian type relation.

  14. Electrolysis for corneal opacities in a young patient with superficial variant of granular corneal dystrophy (Reis-Bücklers corneal dystrophy).

    PubMed

    Kamoi, Mizuka; Mashima, Yukihiko; Kawashima, Motoko; Tsubota, Kazuo

    2005-06-01

    To report the efficacy of electrolysis as a treatment of corneal opacities in a young patient with the superficial variant of granular corneal dystrophy. Interventional case report. An 11-year-old boy presented with subepithelial opacities in both eyes. His visual acuity was 0.2 in the left eye; he received corneal electrolysis under topical anesthesia. The electrolysis, which required only 5 minutes, resulted in the disappearance of the subepithelial opacities. His visual acuity improved to 0.4 on the next day and was 1.0 eight months later. The corneal curvature and thickness were not altered by the electrolysis. Corneal electrolysis proved to be an effective treatment for subepithelial opacities, and we recommend electrolysis as an effective and simple treatment for young patients with SGCD.

  15. Comparison of Astigmatism Induced by Combined Inferior Oblique Anterior Transposition Procedure and Lateral Rectus Recession Alone.

    PubMed

    Eum, Sun Jung; Chun, Bo Young

    2016-12-01

    The purpose of this study is to compare the magnitude and axis of astigmatism induced by a combined inferior oblique (IO) anterior transposition procedure with lateral rectus (LR) recession versus LR recession alone. Forty-six patients were retrospectively analyzed. The subjects were divided into two groups: those having concurrent inferior oblique muscle overaction (IOOA) and intermittent exotropia (group 1, 20 patients) and those having only intermittent exotropia as a control (group 2, 26 patients). Group 1 underwent combined anterior transposition of IO with LR recession and group 2 underwent LR recession alone. Induced astigmatism was defined as the difference between preoperative and postoperative astigmatism using double-angle vector analysis. Cylinder power, axis of induced astigmatism, and spherical equivalent were analyzed at 1 week, 1 month, and 3 months after surgery. Larger changes in the axis of induced astigmatism were observed in group 1, with 4.5° incyclotorsion, than in group 2 at 1 week after surgery (axis, 84.5° vs. 91°; p < 0.001). However, there was no statistically significant inter-group difference thereafter. Relaxation and rapid regression in the incyclotorsion of induced astigmatism were observed over-time. Spherical equivalent significantly decreased postoperatively at 1 month in both groups, indicating a myopic shift ( p = 0.011 for group 1 and p = 0.019 for group 2) but did not show significant differences at 3 months after surgery ( p = 0.107 for group 1 and p = 0.760 for group 2). Combined IO anterior transposition procedures caused an increased change in the axis of induced astigmatism, including temporary incyclotorsion, during the first week after surgery. However, this significant difference was not maintained thereafter. Thus, combined IO surgery with LR recession does not seem to produce a sustained astigmatic change, which can be a potential risk factor of postoperative amblyopia or diplopia compared with LR recession alone.

  16. Construction of a human corneal stromal equivalent with non-transfected human corneal stromal cells and acellular porcine corneal stromata.

    PubMed

    Diao, Jin-Mei; Pang, Xin; Qiu, Yue; Miao, Ying; Yu, Miao-Miao; Fan, Ting-Jun

    2015-03-01

    A tissue-engineered human corneal stroma (TE-HCS) has been developed as a promising equivalent to the native corneal stroma for replacement therapy. However, there is still a crucial need to improve the current approaches to render the TE-HCS equivalent more favorable for clinical applications. At the present study, we constructed a TE-HCS by incubating non-transfected human corneal stromal (HCS) cells in an acellular porcine corneal stromata (aPCS) scaffold in 20% fetal bovine serum supplemented DMEM/F12 (1:1) medium at 37 °C with 5% CO2in vitro. After 3 days of incubation, the constructed TE-HCS had a suitable tensile strength for transplantation, and a transparency that is comparable to native cornea. The TE-HCS had a normal histological structure which contained regularly aligned collagen fibers and differentiated HCS cells with positive expression of marker and functional proteins, mimicking a native HCS. After transplantation into rabbit models, the TE-HCS reconstructed normal corneal stroma in vivo and function well in maintaining corneal clarity and thickness, indicating that the completely biological TE-HCS could be used as a HCS equivalent. The constructed TE-HCS has promising potentials in regenerative medicine and treatment of diseases caused by corneal stromal disorders. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Astigmatism correction of a non-imaging double spectrometer fitted with a 2D array detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaney, P.P.; Ernst, S.L.; Blackshire, J.

    1992-12-01

    A SPEX 1401 double spectrometer was adapted for a liquid nitrogen cooled CCD detector to permit both spectral and spatial analysis of ceramic specimens in a laser Raman microprobe system. The exit image of the spectrometer suffers from astigmatism due to off-axis spherical mirrors. A cylindrical lens was added before the CCD to correct for the astigmatism. The spectrometer and several lenses were modeled using an optical ray tracing program to characterize the astigmatism and to optimize the locations of the lens and the detector. The astigmatism and the spot pattern sizes determined by the model were in good agreementmore » with he observed performance of the modified spectrometer-detector system. Typical spot patterns fell within the 23 {mu}m square pixel size.« less

  18. A method for assessing the accuracy of surgical technique in the correction of astigmatism.

    PubMed

    Kaye, S B; Campbell, S H; Davey, K; Patterson, A

    1992-12-01

    Surgical results can be assessed as a function of what was aimed for, what was done, and what was achieved. One of the aims of refractive surgery is to reduce astigmatism; the smaller the postoperative astigmatism the better the result. Determination of what was done--that is, the surgical effect, can be calculated from the preoperative and postoperative astigmatism. A simplified formulation is described which facilitates the calculation (magnitude and direction) of this surgical effect. In addition, an expression for surgical accuracy is described, as a function of what was aimed for and what was achieved.

  19. Comparison of Moderate- to High-Astigmatism Corrections Using WaveFront-Guided Laser In Situ Keratomileusis and Small-Incision Lenticule Extraction.

    PubMed

    Zhang, Jiamei; Wang, Yan; Chen, Xiaoqin

    2016-04-01

    To evaluate and compare refractive outcomes of moderate- and high-astigmatism correction after wavefront-guided laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). This comparative study enrolled a total of 64 eyes that had undergone SMILE (42 eyes) and wavefront-guided LASIK (22 eyes). Preoperative cylindrical diopters were ≤-2.25 D in moderate- and >-2.25 D in high-astigmatism subgroups. The refractive results were analyzed based on the Alpins vector method that included target-induced astigmatism, surgically induced astigmatism, difference vector, correction index, index of success, magnitude of error, angle of error, and flattening index. All subjects completed the 3-month follow-up. No significant differences were found in the target-induced astigmatism, surgically induced astigmatism, and difference vector between SMILE and wavefront-guided LASIK. However, the average angle of error value was -1.00 ± 3.16 after wavefront-guided LASIK and 1.22 ± 3.85 after SMILE with statistical significance (P < 0.05). The absolute angle of error value was statistically correlated with difference vector and index of success after both procedures. In the moderate-astigmatism group, correction index was 1.04 ± 0.15 after wavefront-guided LASIK and 0.88 ± 0.15 after SMILE (P < 0.05). However, in the high-astigmatism group, correction index was 0.87 ± 0.13 after wavefront-guided LASIK and 0.88 ± 0.12 after SMILE (P = 0.889). Both procedures showed preferable outcomes in the correction of moderate and high astigmatism. However, high astigmatism was undercorrected after both procedures. Axial error of astigmatic correction may be one of the potential factors for the undercorrection.

  20. Meridional lenticular astigmatism associated with bilateral concurrent uveal metastases in renal cell carcinoma.

    PubMed

    Priluck, Joshua C; Grover, Sandeep; Chalam, Kv

    2012-01-01

    To demonstrate a case illustrating meridional lenticular astigmatism as a result of renal cell carcinoma uveal metastases. Case report with images. Clinical findings and diagnostic testing of a patient with acquired meridional lenticular astigmatism are described. The refraction revealed best-corrected visual acuity of 20/20-1 OD (-2.50 + 0.25 × 090) and 20/50 OS (-8.25 + 3.25 × 075). Bilateral concurrent renal cell carcinoma metastases to the choroid and ciliary body are demonstrated by utilizing ultrasonography, ultrawidefield fluorescein angiography, and unique spectral-domain optical coherence tomography. Metastatic disease should be included in the differential of acquired astigmatism. Spectral-domain optical coherence tomography, ultrawidefield fluorescein angiography, and ultrasonography have roles in delineating choroidal metastases.

  1. The Effect of Corneal Epithelium on Corneal Curvature in Patients with Keratoconus.

    PubMed

    Akcay, Emine Kalkan; Uysal, Betul Seher; Sarac, Ozge; Ugurlu, Nagehan; Yulek, Fatma; Cagil, Nurullah; Aslan, Nabi

    2015-01-01

    To investigate the effects of corneal epithelium on corneal curvature in patients with keratoconus. This is a prospective, nonrandomized study. Fifty-nine eyes of 47 patients diagnosed as keratoconus and for whom corneal collagen crosslinking (CXL) was recruited in this study. This study is a single-center clinical trial. Pregnancy, lactation, connective tissue disease, corneal thickness below 350 μm, severe dry eyes, or scar of corneal surgery were exclusion criteria. Before and during CXL procedure after removing the corneal epithelium, maximum values of corneal apical curvature, simulated keratometry 1 (Sim-K1), simulated keratometry 2 (Sim-K2), temporal and inferior curvature values, all of which are 1.5 mm from the corneal center, were calculated. These values before and after removal of epithelium were compared statistically. Mean age of patients was 23.30 ± 5.5 (12-38) years. Twenty-eight (59%) were male while 19 (41%) were female. Mean values measured before and after removing the corneal epithelium were: apical curvature; 59.19 ± 7.2 (47.06-82.40) diopter (D) and 61.70 ± 8.8 (49.19-92.66) D (p = 0.001), SimK1; 47.57 ± 4.3 (39.14-64.57) D and 48.23 ± 4.3 (41.89-66.70) D (p = 0.001), SimK2; 52.04 ± 5.3 (43.56-69.34) D and 53.34 ± 5.6 (43.73-70.89) D (p = 0.001), inferior curvature; 53,85 ± 5.2 (43.47-76.56) D and 55.05 ± 5.8 (44.56-81.93) D (p = 0.002), temporal curvature 49.49 ± 5.1 (41.50-71.03) D and 51.53 ± 5.4 (41.58-73.34) D (p = 0.001), respectively. In keratoconus patients during CXL treatment, after removing the corneal epithelium, more steepness is detected in the curvature of the steeper area of the cornea. When evaluating patients with keratoconus, the masking effect of corneal epithelium on values of curvature should be taken into consideration.

  2. Iris registration in wavefront-guided LASIK to correct mixed astigmatism.

    PubMed

    Khalifa, Mounir; El-Kateb, Mohamed; Shaheen, Mohamed Shafik

    2009-03-01

    To investigate the predictability, safety, and efficiency of wavefront-guided laser in situ keratomileusis (LASIK) with iris-registration technology to correct mixed astigmatism. Vision correction center, Alexandria, Egypt. This retrospective double-blind study included randomly selected patients with mixed astigmatism who sought laser refractive surgery. Patients were divided equally into 3 groups and treated with conventional LASIK and manual marking, wavefront-guided LASIK and manual marking, or wavefront-guided LASIK with iris registration (LASIK+IR group). Eyes were analyzed preoperatively and up to 3 months postoperatively. The LASIK+IR group had better postoperative uncorrected visual acuity (100% 20/30 or better; 90% 20/20 or better; 20% 20/16 or better) than the other groups and did not lose preoperative best spectacle-corrected visual acuity, unlike the other groups. This group also had the highest percentage of eyes that gained lines of acuity (20% 1 line; 10% 2 lines). The LASIK+IR group had the highest predictability of spherical refraction (80% within +/-0.50 diopter [D]; 100% within +/-1.00 D [P<.05] and the highest predictability of cylinder refraction. The LASIK+IR eyes had a significantly smaller increase postoperatively in coma, trefoil, and secondary astigmatism. There was no significant difference between groups in spherical aberration or quadrafoil. The LASIK-IR group had the most improvement in scotopic contrast sensitivity (P<.05). Wavefront-guided LASIK with iris registration was more predictable, safe, and efficient than conventional or wavefront-guided LASIK with manual marking in correcting mixed astigmatism. Further studies are needed to confirm these results.

  3. Convergence Insufficiency, Accommodative Insufficiency, Visual Symptoms, and Astigmatism in Tohono O'odham Students

    PubMed Central

    Twelker, J. Daniel; Miller, Joseph M.; Campus, Irene

    2016-01-01

    Purpose. To determine rate of convergence insufficiency (CI) and accommodative insufficiency (AI) and assess the relation between CI, AI, visual symptoms, and astigmatism in school-age children. Methods. 3rd–8th-grade students completed the Convergence Insufficiency Symptom Survey (CISS) and binocular vision testing with correction if prescribed. Students were categorized by astigmatism magnitude (no/low: <1.00 D, moderate: 1.00 D to <3.00 D, and high: ≥3.00 D), presence/absence of clinical signs of CI and AI, and presence of symptoms. Analyses determine rate of clinical CI and AI and symptomatic CI and AI and assessed the relation between CI, AI, visual symptoms, and astigmatism. Results. In the sample of 484 students (11.67 ± 1.81 years of age), rate of symptomatic CI was 6.2% and symptomatic AI 18.2%. AI was more common in students with CI than without CI. Students with AI only (p = 0.02) and with CI and AI (p = 0.001) had higher symptom scores than students with neither CI nor AI. Moderate and high astigmats were not at increased risk for CI or AI. Conclusions. With-the-rule astigmats are not at increased risk for CI or AI. High comorbidity rates of CI and AI and higher symptoms scores with AI suggest that research is needed to determine symptomatology specific to CI. PMID:27525112

  4. Visual acuity and astigmatism in periocular infantile hemangiomas treated with oral beta-blocker versus intralesional corticosteroid injection.

    PubMed

    Herlihy, Erin P; Kelly, John P; Sidbury, Robert; Perkins, Jonathan A; Weiss, Avery H

    2016-02-01

    Periocular infantile hemangiomas (PIH) can induce anisometropic astigmatism, a risk factor for amblyopia. Oral beta-blocker therapy has largely supplanted systemic or intralesional corticosteroids. The purpose of this study was to evaluate the effect and time course of these treatment modalities on visual acuity and induced astigmatism. The medical records of patients with PIH treated with oral propanolol between November 2008 and July 2013 were retrospectively reviewed for data on visual acuity and astigmatism. Patients with incomplete pre- and post-treatment ophthalmic examinations were excluded. Results were compared to those of a similar cohort treated with intralesional corticosteroid injection. Mean astigmatism in affected eyes was 1.90 D before propranolol and 1.00 D after; patients showed a monophasic reduction in astigmatism over 12 months. By comparison, patients treated with corticosteroid injection showed a biphasic response, with an immediate steep decrease followed by a slow monophasic decline, paralleling propranolol-treated patients. Oral propranolol treatment caused a 47% reduction in mean induced astigmatism, less than the 63% reduction reported for the cohort treated with corticosteroid. No patient had visual acuity in the affected eye more than 1 standard devation below the age-matched norm, and none experienced significant side effects when treated with oral propranolol. In this patient cohort oral beta-blocker was well-tolerated. Treatment was therefore often initiated prior to the induction of significant astigmatism, with treatment effects comparable to steroid treatment. Visual outcomes were good. Early treatment may minimize the potential effect of astigmatism on postnatal visual development. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  5. Short-term effects of overnight orthokeratology on corneal cell morphology and corneal thickness.

    PubMed

    Nieto-Bona, Amelia; González-Mesa, Ana; Nieto-Bona, Ma Paz; Villa-Collar, César; Lorente-Velázquez, Amalia

    2011-06-01

    To examine the morphological and biometric corneal changes produced over periods of 15 days and 1 month after overnight orthokeratology (OK). Prospective, single-center, longitudinal trial. Twenty-seven right eyes of 27 subjects (group 1) with low to moderate myopia wore OK lenses for 1 month. Ten right eyes of 10 subjects (group 2) with emmetropia to low myopia who did not wear any type of contact lens served as controls. Corneal morphometric measurements were obtained in vivo using a confocal microscope to examine the central and midperipheral cornea. Thickness measurements in the peripheral cornea were obtained by optical coherence tomography. Changes in visual acuity, refractive error, and corneal topography were also analyzed. No significant changes in either endothelial cell or stromal cell density were observed after 1 month of OK. Basal epithelial cells were, however, significantly reduced (P < 0.01), and epithelial wing and superficial cells showed enhanced visibility (P < 0.05). Superficial cells increased in height and width, the width increase after 1 month being significant (P < 0.01). Epithelial thickness was significantly reduced in the central cornea and 2 mm around the center. Corneal pachymetry increased significantly in the band from 5 to 10 mm from the corneal apex (P < 0.01). OK lenses for myopia induce significant structural and optical changes particularly in the central epithelium after 15 days or 1 month of wear. The central corneal epithelium responds to OK wear by undergoing significant epithelial cell shape and size alterations with no effects, however, on the cells of the corneal endothelium or the corneal stroma. Peripheral corneal thickness increased with respect to baseline values. These findings suggest that the corneal epithelium is the principal structure affected by the mechanical forces exerted by the OK lenses.

  6. Effect of corneal wetting solutions on corneal thickness during ophthalmic surgery.

    PubMed

    Emre, Sinan; Akkin, Cezmi; Afrashi, Filiz; Yağci, Ayşe

    2002-01-01

    To measure the changes in corneal thickness with wetting solutions used in ophthalmic surgery. Ege University, School of Medicine, Department of Ophthalmology, Izmir, Turkey. Thirty-one adult pigmented rabbits that weighed about 2.5 kg each were anesthetized with pentobarbital sodium. The rabbits were randomly divided into 3 groups to receive 3 wetting solutions: Group 1, Ringer's lactate; Group 2, balanced salt solution (BSS); and Group 3, BSS with glutation (BSS Plus). The solutions were dropped on the right cornea of the rabbits at a rate of 6.0 cc in 12 minutes using an intravenous infusion pump. Corneal thickness was measured by ultrasonic pachymetry before and after the procedure, and the between-group changes in corneal thickness were compared. The corneal thickness before and after the procedure was 361.27 microm +/- 19.3 (SD) and 380.00 +/- 25.0 microm, respectively, in Group 1 (P =.000); 372.10 +/- 18.8 microm and 388.60 +/- 24.1 microm, respectively, in Group 2 (P =.003); and 358.10 +/- 26.5 microm and 360.10 +/- 24.1 microm, respectively, in Group 3 (P =.316). As a corneal wetting solution, BSS Plus resulted in significantly fewer changes in corneal thickness than Ringer's lactate or BSS. This should be considered in cases involving long intraocular surgery.

  7. Meridional lenticular astigmatism associated with bilateral concurrent uveal metastases in renal cell carcinoma

    PubMed Central

    Priluck, Joshua C; Grover, Sandeep; Chalam, KV

    2012-01-01

    Purpose To demonstrate a case illustrating meridional lenticular astigmatism as a result of renal cell carcinoma uveal metastases. Methods Case report with images. Results Clinical findings and diagnostic testing of a patient with acquired meridional lenticular astigmatism are described. The refraction revealed best-corrected visual acuity of 20/20–1 OD (−2.50 + 0.25 × 090) and 20/50 OS (−8.25 + 3.25 × 075). Bilateral concurrent renal cell carcinoma metastases to the choroid and ciliary body are demonstrated by utilizing ultrasonography, ultrawidefield fluorescein angiography, and unique spectral-domain optical coherence tomography. Conclusions Metastatic disease should be included in the differential of acquired astigmatism. Spectral-domain optical coherence tomography, ultrawidefield fluorescein angiography, and ultrasonography have roles in delineating choroidal metastases. PMID:23152663

  8. Optical advantages of astigmatic aberration corrected heliostats

    NASA Astrophysics Data System (ADS)

    van Rooyen, De Wet; Schöttl, Peter; Bern, Gregor; Heimsath, Anna; Nitz, Peter

    2016-05-01

    Astigmatic aberration corrected heliostats adapt their shape in dependence of the incidence angle of the sun on the heliostat. Simulations show that this optical correction leads to a higher concentration ratio at the target and thus in a decrease in required receiver aperture in particular for smaller heliostat fields.

  9. Holmium:YAG thermokeratoplasty: treatment parameters for the correction of astigmatism based upon enucleated human eyes using an application mask

    NASA Astrophysics Data System (ADS)

    Kriegerowski, Martin; Rassmann, Katja; Oltrup, Theo; Bende, Thomas; Jean, Benedikt J.

    1995-05-01

    The refractive outcome of thermokeratoplasty depends upon the location and angle of the coagulation spots, applied with a focusing handpiece onto the corneal surface. Accuracy can be enhanced using a specially designed application mask. An astigmatism correction was performed on 10 human donor eyes (Holmium 25, Technomed, FRG, 15 Hz, 20 mJ/pulse, 25 pulses) with an optical zone of 8.1 mm, 5 eyes received a free hand laser application (marked positions) and the other 5 eyes were treated using a suctioned metal mask with drills for the handpiece (optical zone 8.1 mm). To compare the results a silicone replica was taken and analyzed by a confocal laser microtopometer. The refractive change for the steepest meridian was 10 D with a standard deviation of +/- 3.7 D for the free hand application. Using the application mask the refractive outcome was 9.8 D with a standard deviation of only 0.8 D. Using the application mask the standard deviation for the induced refractive change decreases by a factor of five.

  10. Corneal electrolysis for recurrence of corneal stromal dystrophy after keratoplasty

    PubMed Central

    Mashima, Y; Kawai, M; Yamada, M

    2002-01-01

    Aims: To evaluate corneal electrolysis as a treatment for recurrent diffuse corneal opacities at the host-graft interface of the stroma or at the subepithelial region in two types of granular corneal dystrophy (GCD). Methods: Recurrence developed at the host-graft interface of the stroma after lamellar keratoplasty in a patient with Avellino corneal dystrophy (ACD). At surgery, the deep aspect of the graft in this patient was partially separated from host tissue to expose the deposits, with one third of the host-graft junction left intact. The graft was everted, and electrolysis was applied directly to remove the deposits attached to both surfaces of the host and the graft. Then the graft was returned to its place and sutured. In two patients with homozygous ACD and one patient with the superficial variant of GCD, diffuse subepithelial opacities developed following penetrating keratoplasty. Electrolysis was applied directly to the corneal surface. Results: Deposits at the host-graft interface of the stroma and in the subepithelial region disappeared following treatment, and vision recovered in all patients. Conclusions: This method is a simple, easy, and inexpensive way to remove deposits that recur after lamellar or penetrating keratoplasty. PMID:11864880

  11. Corneal electrolysis for recurrence of corneal stromal dystrophy after keratoplasty.

    PubMed

    Mashima, Y; Kawai, M; Yamada, M

    2002-03-01

    To evaluate corneal electrolysis as a treatment for recurrent diffuse corneal opacities at the host-graft interface of the stroma or at the subepithelial region in two types of granular corneal dystrophy (GCD). Recurrence developed at the host-graft interface of the stroma after lamellar keratoplasty in a patient with Avellino corneal dystrophy (ACD). At surgery, the deep aspect of the graft in this patient was partially separated from host tissue to expose the deposits, with one third of the host-graft junction left intact. The graft was everted, and electrolysis was applied directly to remove the deposits attached to both surfaces of the host and the graft. Then the graft was returned to its place and sutured. In two patients with homozygous ACD and one patient with the superficial variant of GCD, diffuse subepithelial opacities developed following penetrating keratoplasty. Electrolysis was applied directly to the corneal surface. Deposits at the host-graft interface of the stroma and in the subepithelial region disappeared following treatment, and vision recovered in all patients. This method is a simple, easy, and inexpensive way to remove deposits that recur after lamellar or penetrating keratoplasty.

  12. A Comparative Study of Clear Corneal Phacoemulsification with Rigid IOL Versus SICS; the Preferred Surgical Technique in Low Socio-economic group Patients of Rural Areas.

    PubMed

    Devendra, Jaya; Agarwal, Smita; Singh, Pankaj Kumar

    2014-11-01

    Low socio-economic group patients from rural areas often opt for free cataract surgeries offered by charitable organisations. SICS continues to be a time tested technique for cataract removal in such patients. In recent times, camp patients are sometimes treated by clear corneal phacoemulsification with implantation of a rigid IOL, which being more cost effective is often provided for camp patients. This study was undertaken to find out which surgical technique yielded better outcomes and was more suited for high volume camp surgery. To find the better surgical option- phacoemulsification with rigid IOL or SICS, in poor patients from rural areas. A prospective randomised controlled trial of cataract patients operated by two different techniques. One hundred and twelve eyes were selected and were randomly allocated into two groups of 56 eyes each. At completion of the study, data was analysed for 52 eyes operated by clear corneal phacoemulsification and implantation of a rigid IOL, and 56 eyes operated by SICS. Unpaired t-test was used to calculate the p- value. The results were evaluated on the following criteria. The mean post-operative astigmatism at the end of four weeks - was significantly higher in phacoemulsification group as compared to SICS group The BCVA (best corrected visual acuity) at the end of four weeks - was comparable in both groups. Subjective complaints and/ or complications: In phaco group two patients required sutures and seven had striate keratitis , while none in SICS group. Complaint of irritation was similar in both groups. Surgical time- was less for SICS group as compared to phaco group. SICS by virtue of being a faster surgery with more secure wound and significantly less astigmatism is a better option in camp patients from rural areas as compared to phacoemulsification with rigid IOL.

  13. Comparison of Astigmatism Induced by Combined Inferior Oblique Anterior Transposition Procedure and Lateral Rectus Recession Alone

    PubMed Central

    Eum, Sun Jung

    2016-01-01

    Purpose The purpose of this study is to compare the magnitude and axis of astigmatism induced by a combined inferior oblique (IO) anterior transposition procedure with lateral rectus (LR) recession versus LR recession alone. Methods Forty-six patients were retrospectively analyzed. The subjects were divided into two groups: those having concurrent inferior oblique muscle overaction (IOOA) and intermittent exotropia (group 1, 20 patients) and those having only intermittent exotropia as a control (group 2, 26 patients). Group 1 underwent combined anterior transposition of IO with LR recession and group 2 underwent LR recession alone. Induced astigmatism was defined as the difference between preoperative and postoperative astigmatism using double-angle vector analysis. Cylinder power, axis of induced astigmatism, and spherical equivalent were analyzed at 1 week, 1 month, and 3 months after surgery. Results Larger changes in the axis of induced astigmatism were observed in group 1, with 4.5° incyclotorsion, than in group 2 at 1 week after surgery (axis, 84.5° vs. 91°; p < 0.001). However, there was no statistically significant inter-group difference thereafter. Relaxation and rapid regression in the incyclotorsion of induced astigmatism were observed over-time. Spherical equivalent significantly decreased postoperatively at 1 month in both groups, indicating a myopic shift (p = 0.011 for group 1 and p = 0.019 for group 2) but did not show significant differences at 3 months after surgery (p = 0.107 for group 1 and p = 0.760 for group 2). Conclusions Combined IO anterior transposition procedures caused an increased change in the axis of induced astigmatism, including temporary incyclotorsion, during the first week after surgery. However, this significant difference was not maintained thereafter. Thus, combined IO surgery with LR recession does not seem to produce a sustained astigmatic change, which can be a potential risk factor of postoperative amblyopia or

  14. Association between culture results of corneal scrapings and culture and histopathology results of corneal tissues in therapeutic keratoplasty.

    PubMed

    Das, Sujata; Sharma, Savitri; Priyadarshini, Omega; Sahu, Srikant K; Kar, Sarita; Vemuganti, Geeta K

    2011-09-01

    To correlate the culture results of corneal scrapings with culture and histopathology results of corneal tissues in therapeutic keratoplasty. A retrospective analysis of the culture results of corneal scrapings and corneal tissues of eyes that received therapeutic penetrating keratoplasty at a tertiary eye care center between December 2006 and November 2008 was conducted. As per the preferred practice, those cases that did not respond to appropriate antimicrobial therapy and/or presented with a large infiltrate/perforation received therapeutic keratoplasty. The microbiology and histopathology findings of the corneal tissues were compared. Thirty-eight therapeutic keratoplasties were performed on 36 patients. Although all cases had histopathology and culture of the corneal tissue, corneal scrapings were not performed in 4 cases. Corneal scrapings and corneal tissues were culture-positive in 76% (26 of 34) and 60% (23 of 38) of cases, respectively. In 8 cases, the corneal scrapings and corneal tissues yielded identical organisms, whereas different organisms grew in 4 cases. In 6 cases, the corneal tissues were culture-positive but the corneal scrapings were sterile. In 20 cases, the corneal tissues were culture-positive for fungus and also showed fungal filaments in their corresponding histopathology specimens. Corneal tissue culture can provide additional information in cases undergoing therapeutic keratoplasty. It helps to determine the management of patients after keratoplasty.

  15. LASIK versus photorefractive keratectomy for high myopic (> 3 diopter) astigmatism.

    PubMed

    Katz, Toam; Wagenfeld, Lars; Galambos, Peter; Darrelmann, Benedikt Große; Richard, Gisbert; Linke, Stephan Johannes

    2013-12-01

    To compare the efficacy, safety, predictability, and vector analysis indices of LASIK and photorefractive keratectomy (PRK) for correction of high cylinder of greater than 3 diopters (D) in myopic eyes. The efficacy, safety, and predictability of LASIK or PRK performed in 114 consecutive randomly selected myopic eyes with an astigmatism of greater than 3 D were retrospectively analyzed at the 2- to 6-month follow-up visits. Vector analysis of the cylindrical correction was compared between the treatment groups. A total of 57 eyes receiving PRK and 57 eyes receiving LASIK of 114 refractive surgery candidates were enrolled in the study. No statistically significant difference in efficacy [efficacy index = 0.76 (±0.32) for PRK vs 0.74 (±0.19) for LASIK (P = .82)], safety [safety index = 1.10 (±0.26) for PRK vs 1.01 (±0.17) for LASIK (P = .121)], or predictability [achieved astigmatism < 1 D in 39% of PRK- and 54% of LASIK-treated eyes, and < 2 D in 88% of PRK- and 89% of LASIK-treated eyes (P = .218)] was demonstrated. Using Alpins vector analysis, the surgically induced astigmatism and difference vector were not significantly different between the surgery methods, whereas the correction index showed a slight and significant advantage of LASIK over PRK (1.25 for PRK and 1.06 for LASIK, P < .001). LASIK and PRK are comparably safe, effective, and predictable procedures for excimer laser correction of high astigmatism of greater than 3 D in myopic eyes. Predictability of the correction of the cylindrical component is lower than that of the spherical equivalent. Copyright 2013, SLACK Incorporated.

  16. Corneal tissue welding with infrared laser irradiation after clear corneal incision.

    PubMed

    Rasier, Rfat; Ozeren, Mediha; Artunay, Ozgür; Bahçecioğlu, Halil; Seçkin, Ismail; Kalaycoğlu, Hamit; Kurt, Adnan; Sennaroğlu, Alphan; Gülsoy, Murat

    2010-09-01

    The aim of this study was to investigate the potential of infrared lasers for corneal welding to seal corneal cuts done in an experimental animal model. Full-thickness corneal cuts on freshly enucleated bovine eyes were irradiated with infrared (809-nm diode, 980-nm diode, 1070-nm YLF, and 1980-nm Tm:YAP) lasers to get immediate laser welding. An 809-nm laser was used with the topical application of indocyanine green to enhance the photothermal interaction at the weld site. In total, 60 bovine eyes were used in this study; 40 eyes were used in the first part of the study for the determination of optimal welding parameters (15 eyes were excluded because of macroscopic carbonization, opacification, or corneal shrinkage; 2 eyes were used for control), and 20 eyes were used for further investigation of more promising lasers (YLF and Tm:YAP). Laser wavelength, irradiating power, exposure time, and spot size were the dose parameters, and optimal dose for immediate closure with minimal thermal damage was estimated through histological examination of welded samples. In the first part of the study, results showed that none of the applications was satisfactory. Full-thickness success rates were 28% (2 of 7) for 809-nm and for 980-nm diode lasers and 67% (2 of 3) for 1070-nm YLF and (4 of 6) for 1980-nm Tm:YAP lasers. In the second part of the study, YLF and Tm:YAP lasers were investigated with bigger sample size. Results were not conclusive but promising again. Five corneal incisions were full-thickness welded out of 10 corneas with 1070-nm laser, and 4 corneal incisions were partially welded out of 10 corneas with 1980-nm laser in the second part of the study. Results showed that noteworthy corneal welding could be obtained with 1070-nm YLF laser and 1980-nm Tm:YAP laser wavelengths. Furthermore, in vitro and in vivo studies will shed light on the potential usage of corneal laser welding technique.

  17. Corneal repair by human corneal keratocyte-reprogrammed iPSCs and amphiphatic carboxymethyl-hexanoyl chitosan hydrogel.

    PubMed

    Chien, Yueh; Liao, Yi-Wen; Liu, Dean-Mo; Lin, Heng-Liang; Chen, Shih-Jen; Chen, Hen-Li; Peng, Chi-Hsien; Liang, Chang-Min; Mou, Chung-Yuan; Chiou, Shih-Hwa

    2012-11-01

    Induced pluripotent stem cells (iPSCs) have promising potential in regenerative medicine, but whether iPSCs can promote corneal reconstruction remains undetermined. In this study, we successfully reprogrammed human corneal keratocytes into iPSCs. To prevent feeder cell contamination, these iPSCs were cultured onto a serum- and feeder-free system in which they remained stable through 30 passages and showed ESC-like pluripotent property. To investigate the availability of iPSCs as bioengineered substitutes in corneal repair, we developed a thermo-gelling injectable amphiphatic carboxymethyl-hexanoyl chitosan (CHC) nanoscale hydrogel and found that such gel increased the viability and CD44+proportion of iPSCs, and maintained their stem-cell like gene expression, in the presence of culture media. Combined treatment of iPSC with CHC hydrogel (iPSC/CHC hydrogel) facilitated wound healing in surgical abrasion-injured corneas. In severe corneal damage induced by alkaline, iPSC/CHC hydrogel enhanced corneal reconstruction by downregulating oxidative stress and recruiting endogenous epithelial cells to restore corneal epithelial thickness. Therefore, we demonstrated that these human keratocyte-reprogrammed iPSCs, when combined with CHC hydrogel, can be used as a rapid delivery system to efficiently enhance corneal wound healing. In addition, iPSCs reprogrammed from corneal surgical residues may serve as an alternative cell source for personalized therapies for human corneal damage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Two-year results of femtosecond assisted LASIK versus PRK for different severity of astigmatism.

    PubMed

    Miraftab, Mohammad; Hashemi, Hassan; Asgari, Soheila

    2018-03-01

    To compare two-year results of femtosecond laser assisted LASIK (femto-LASIK) and photorefractive keratectomy (PRK) in terms of astigmatism correction in patients with less than 2.0 diopters (D) of spherical error and more than 2.0 D of cylinder error. In this retrospective study, data were extracted from 100 patient charts. The two study groups were matched by age, gender, and baseline uncorrected distance visual acuity (UDVA) and refractive astigmatism (RA). Preoperative astigmatism was categorized as mild: 2.00 to <3.00 D, moderate: 3.00 to <4.00 D, and severe: ≥4.00 D. Mean RA in the femto-LASIK and PRK groups was respectively -3.15 ± 0.94 D (-7.00 to -2.00 D) and -3.29 ± 0.95 D (-6.25 to -2.00 D) at baseline ( P  = 0.284), and -0.61 ± 0.40 D and -0.62 ± 0.60 D one year after surgery ( P  = 0.674), but significantly lower in the femto-LASIK group (-0.61 ± 0.39 vs. -0.83 ± 0.56 D, P  = 0.021) at 2 years when the rate of residual astigmatism more than 1.0 D was 6.3% in the femto-LASIK and 19.6% in the PRK group ( P  = 0.046). Mean UDVA in the femto-LASIK group (0.02 ± 0.05 logMAR) was better than the PRK group (0.06 ± 0.10 logMAR) ( P  = 0.025). Mean corrected distance visual acuity (CDVA) was not significantly different between groups (0.01 ± 0.03 vs. 0.01 ± 0.04 logMAR, P  = 0.714). Both groups had 1-4 Snellen lines CDVA improvement. The three subgroups of baseline astigmatism did not differ significantly in terms of residual astigmatism (all P  > 0.05). However, in subgroups with ≥4.00 D cylinder, there was less astigmatic regression at 1 year in the femto-LASIK group (0.28 ± 0.43 D) than the PRK group (0.54 ± 0.68 D) ( P  = 0.007). Our results pointed to better two-year results with femto-LASIK in the treatment of different degrees of astigmatism. UDVA improvement was superior with femto-LASIK, but the two methods did not significantly differ in terms of CDVA improvement.

  19. New refractive method for laser thermal keratoplasty with the Co:MgF2 laser.

    PubMed

    Horn, G; Spears, K G; Lopez, O; Lewicky, A; Yang, X Y; Riaz, M; Wang, R; Silva, D; Serafin, J

    1990-09-01

    We have observed corneal curvature changes from laser thermal keratoplasty with a Co:MgF2 laser. We studied corneal curvature changes in rabbits and have identified specific treatment patterns and laser parameters that can correct myopia and astigmatism. These corneal changes, some as large as 8 diopters, have been stable for at least one year, and slitlamp examination demonstrates clear central corneas with normal appearance.

  20. [Fitting Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lenses in keratoconus patients: a prospective randomized comparative clinical trial].

    PubMed

    Coral-Ghanem, Cleusa; Alves, Milton Ruiz

    2008-01-01

    To evaluate the clinical performance of Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lens fitting in patients with keratoconus. A prospective and randomized comparative clinical trial was conducted with a minimum follow-up of six months in two groups of 63 patients. One group was fitted with Monocurve contact lenses and the other with Bicurve Soper-McGuire design. Study variables included fluoresceinic pattern of lens-to-cornea fitting relationship, location and morphology of the cone, presence and degree of punctate keratitis and other corneal surface alterations, topographic changes, visual acuity for distance corrected with contact lenses and survival analysis for remaining with the same contact lens design during the study. During the follow-up there was a decrease in the number of eyes with advanced and central cones fitted with Monocurve lenses, and an increase in those fitted with Soper-McGuire design. In the Monocurve group, a flattening of both the steepest and the flattest keratometric curve was observed. In the Soper-McGuire group, a steepening of the flattest keratometric curve and a flattening of the steepest keratometric curve were observed. There was a decrease in best-corrected visual acuity with contact lens in the Monocurve group. Survival analysis for the Monocurve lens was 60.32% and for the Soper-McGuire was 71.43% at a mean follow-up of six months. This study showed that due to the changes observed in corneal topography, the same contact lens design did not provide an ideal fitting for all patients during the follow-up period. The Soper-McGuire lenses had a better performance than the Monocurve lenses in advanced and central keratoconus.

  1. Corneal clouding in Alport syndrome.

    PubMed

    Herwig, Martina C; Eter, Nicole; Holz, Frank G; Loeffler, Karin U

    2011-03-01

    Alport syndrome is a hereditary basement membrane disease that typically involves the kidney, the cochlea, and the eyes. Characteristic ocular problems include posterior polymorphous corneal dystrophy, lenticonus, and dot-and-fleck retinopathy. A 48-year-old male patient with Alport syndrome presented with corneal and retinal changes. In 2003, he was diagnosed with posterior polymorphous corneal dystrophy and received a corneal transplant in his left eye in 2007 because of progressive deterioration in visual acuity. At this time, a lamellar macular hole was diagnosed in his right eye. The removed corneal button was examined by light and electron microscopy and by immunohistochemistry. Histology revealed not only endothelial changes but also a marked irregular thickening of the epithelial basement membrane and of Bowman layer. Alcian blue staining demonstrated an accumulation of mucopolysaccharides in the Bowman layer. The presented changes underline the great variation of ocular disorders related to Alport syndrome. To our knowledge, this is one of the first reports describing histologic corneal findings in Alport syndrome. Only a few cases with accumulation of mucopolysaccharides in the Bowman layer have been described previously, none of them being associated with Alport syndrome. Besides, anterior corneal alterations and corneal clouding seem to be uncommon in patients suffering from Alport syndrome.

  2. Corneal markers of diabetic neuropathy.

    PubMed

    Pritchard, Nicola; Edwards, Katie; Shahidi, Ayda M; Sampson, Geoff P; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan

    2011-01-01

    Diabetic neuropathy is a significant clinical problem that currently has no effective therapy, and in advanced cases, leads to foot ulceration and lower limb amputation. The accurate detection, characterization and quantification of this condition are important in order to define at-risk patients, anticipate deterioration, monitor progression, and assess new therapies. This review evaluates novel corneal methods of assessing diabetic neuropathy. Two new noninvasive corneal markers have emerged, and in cross-sectional studies have demonstrated their ability to stratify the severity of this disease. Corneal confocal microscopy allows quantification of corneal nerve parameters and noncontact corneal esthesiometry, the functional correlate of corneal structure, assesses the sensitivity of the cornea. Both these techniques are quick to perform, produce little or no discomfort for the patient, and are suitable for clinical settings. Each has advantages and disadvantages over traditional techniques for assessing diabetic neuropathy. Application of these new corneal markers for longitudinal evaluation of diabetic neuropathy has the potential to reduce dependence on more invasive, costly, and time-consuming assessments, such as skin biopsy.

  3. Drug-induced corneal damage.

    PubMed

    2014-04-01

    Corneal damage can have a variety of causes, including infections, chemical splashes, environmental factors (radiation, trauma, contact lenses, etc.), and systemic diseases (genetic, autoimmune, inflammatory, metabolic, etc.). A wide range of drugs can also damage the cornea. The severity of drug-induced corneal changes can range from simple asymptomatic deposits to irreversible, sight-threatening damage. Several factors can influence the onset of corneal lesions. Some factors, such as the dose, are treatment-related, while others such as contact lenses, are patient-related. A variety of mechanisms may be involved, including corneal dryness, changes in the corneal epithelium, impaired wound healing and deposits. Many drugs can damage the cornea through direct contact, after intraocular injection or instillation, including VEGF inhibitors, anti-inflammatory drugs, local anaesthetics, glaucoma drugs, fluoroquinolones, and preservatives. Some systemically administered drugs can also damage the cornea, notably cancer drugs, amiodarone and isotretinoin. Vulnerable patients should be informed of this risk if they are prescribed a drug with the potential to damage the cornea so that they can identify problems in a timely manner. It may be necessary to discontinue the suspect drug when signs and symptoms of corneal damage occur.

  4. Neurotrophic factors and corneal nerve regeneration

    PubMed Central

    Sacchetti, Marta; Lambiase, Alessandro

    2017-01-01

    The cornea has unique features that make it a useful model for regenerative medicine studies. It is an avascular, transparent, densely innervated tissue and any pathological changes can be easily detected by slit lamp examination. Corneal sensitivity is provided by the ophthalmic branch of the trigeminal nerve that elicits protective reflexes such as blinking and tearing and exerts trophic support by releasing neuromediators and growth factors. Corneal nerves are easily evaluated for both function and morphology using standard instruments such as corneal esthesiometer and in vivo confocal microscope. All local and systemic conditions that are associated with damage of the trigeminal nerve cause the development of neurotrophic keratitis, a rare degenerative disease. Neurotrophic keratitis is characterized by impairment of corneal sensitivity associated with development of persistent epithelial defects that may progress to corneal ulcer, melting and perforation. Current neurotrophic keratitis treatments aim at supporting corneal healing and preventing progression of corneal damage. Novel compounds able to stimulate corneal nerve recovery are in advanced development stage. Among them, nerve growth factor eye drops showed to be safe and effective in stimulating corneal healing and improving corneal sensitivity in patients with neurotrophic keratitis. Neurotrophic keratitis represents an useful model to evaluate in clinical practice novel neuro-regenerative drugs. PMID:28966630

  5. Six-month clinical outcomes after hyperopic correction with the SCHWIND AMARIS Total-Tech laser

    PubMed Central

    Arbelaez, María Clara; Vidal, Camila; Arba Mosquera, Samuel

    2011-01-01

    Purpose To evaluate postoperative clinical outcomes, and corneal High Order Aberrations, among eyes with hyperopia up to +5 D of spherical equivalent, that have undergone LASIK treatments using the SCHWIND AMARIS laser system. Methods At six-month follow-up, 100 eyes with preoperative hyperopia or hyperopic astigmatism up to +5 D of spherical equivalent were retrospectively analysed. Standard examinations, pre- and postoperative wavefront analysis with a corneal-wavefront-analyzer (OPTIKON Scout) were performed. Aberration-Free aspheric treatments were planned with Custom Ablation Manager software and ablations performed using the SCHWIND AMARIS flying-spot excimer laser system (both SCHWIND eye-tech-solutions). LASIK flaps were created using a LDV femtosecond laser (Ziemer Group) in all cases. Clinical outcomes were evaluated in terms of predictability, refractive outcome, safety, and wavefront aberration. Results At six month, 90 % of eyes achieved ≥ 20/25 UCVA and 44 % achieved ≥ 20/16 UCVA. Seventy-four percent of eyes were within ± 0.25D of spherical equivalent and 89 % within ± 0.50D, with 94 % within 0.50D of astigmatism. Mean spherical equivalent was −0.12 ± 0.51D and 0.50 ± 0.51D for the astigmatism. Fifty-two percent of eyes improved BSCVA vs. only 19 % losing lines of BSCVA. Predictability slope for refraction was 1.03 and intercept +0.01 D. On average, negative corneal spherical aberrations were significantly increased by the treatments, no other aberration terms changed from pre- to postoperative values. Conclusions LASIK for hyperopia and hyperopic astigmatism with SCHWIND AMARIS yields very satisfactory visual outcomes. Preoperative refractions were postoperatively reduced to subclinical values with no clinically relevant induction of corneal HOA.

  6. [To Protect Corneal Transparency against Diseases].

    PubMed

    Usui, Tomohiko

    2016-03-01

    To protect corneal transparency, we tried to develop a new therapeutic strategy for corneal neovascularization, corneal scar, and TGFBI-related corneal dystrophy using nucleic acid drug. 1. The expression of angiopietin-like protein 2 (Angptl2) markedly increased in the neovascularized corneas compared to the normal cornea, and Angtpl2 was(a potent inducer of inflammatory corneal neovascularization. We have produced a single-stranded proline-modified short hairpin anti-Angptl2 ribonucleric acid interference (RNAi) molecule that is carried in a lipid nanoparticle for topical application. We have found this agent can penetrate all layers of the cornea. Angptl2 mRNA expression and corneal neovascularization were inhibited in a mouse alkari injury model by topical application of this agent. Thus, this modified RNAi agent is a new topical formulation for use against corneal neovascularization and scar. 2. Human umbilical vein endothelial cells (HUVECs) were cultured with human corneal keratocytes under serum-free conditions. We performed microarray gene-expression analysis in the coculture system and selected angiopoietin-like protein 7 (Angptl7). In vivo, intrastromal injections of an anti-Angptl7 RNAi agent into the avascular corneal stroma of mice resulted in the growth of blood vessels. Further, we examined the effects of Angptl7 on corneal nerves using culture rat trigeminal cells and this molecule had neurotrophic property on the cornea. Thus, Angpt17 is a unique molecule, which contain its bilateral character (anti-angiogenic and neurotrophic) in the cornea; an agonistic nucleic acid drug for Angptl7 may be a new therapeutic tool for protecting corneal transparency. 3. We examined local gene editing for TGFBI-related corneal dystrophy using CRISPR-Cas9 mediated homology directed repair (HDR). Cultured corneal keratocytes were obtained from a patient of R124H granular dystrophy. The R124H gene arrangement was corrected by a tranfection of guide RNA and HDR repair

  7. The effects of induced oblique astigmatism on symptoms and reading performance while viewing a computer screen.

    PubMed

    Rosenfield, Mark; Hue, Jennifer E; Huang, Rae R; Bababekova, Yuliya

    2012-03-01

    Computer vision syndrome (CVS) is a complex of eye and vision problems related to computer use which has been reported in up to 90% of computer users. Ocular symptoms may include asthenopia, accommodative and vergence difficulties and dry eye. Previous studies have reported that uncorrected astigmatism may have a significant impact on symptoms of CVS. However, its effect on task performance is unclear. This study recorded symptoms after a 10 min period of reading from a computer monitor either through the habitual distance refractive correction or with a supplementary -1.00 or -2.00D oblique cylinder added over these lenses in 12 young, visually-normal subjects. Additionally, the distance correction condition was repeated to assess the repeatability of the symptom questionnaire. Subjects' reading speed and accuracy were monitored during the course of the 10 min trial. There was no significant difference in reading rate or the number of errors between the three astigmatic conditions. However, a significant change in symptoms was reported with the median total symptom scores for the 0, 1 and 2D astigmatic conditions being 2.0, 6.5 and 40.0, respectively (p < 0.0001). Further, the repeatability coefficient of the total symptom score following the repeated zero astigmatism condition was ± 13.46. The presence of induced astigmatism produced a significant increase in post-task symptoms but did not affect reading rate or the number of reading errors. The correction of small astigmatic refractive errors may be important in optimizing patient comfort during computer operation. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.

  8. Evaluation of the toric implantable collamer lens for simultaneous treatment of myopia and astigmatism.

    PubMed

    Price, Marianne O; Price, Francis W

    2015-01-01

    Myopic astigmatism is a prevalent condition that can be treated with spectacles, contact lenses, or laser refractive surgery. However, these treatment options have functional limitations at higher levels of refractive error. The toric implantable collamer lens is designed to treat a broad range of refractive error, generally up to -18 diopters with +1 to +6 diopters of astigmatism. Approval for a more limited treatment range of up to 15 diopters of myopia with +1 to +4 diopters of astigmatism is being sought in the US, where this device has not yet received marketing approval. Surgical correction of high-myopic astigmatism can be life-altering and allow people to participate in activities that were not previously feasible because of visual limitations. The toric implantable collamer lens is implanted behind the iris and in front of the natural crystalline lens. With earlier lens designs, it was necessary to create an iridectomy or iridotomy to prevent pupillary block. The newest toric implantable collamer lens model has a small central hole that is not visually noticeable. This eliminates the need to create a hole in the iris, thereby enhancing the safety of the procedure.

  9. Corneal blindness: a global perspective.

    PubMed Central

    Whitcher, J. P.; Srinivasan, M.; Upadhyay, M. P.

    2001-01-01

    Diseases affecting the cornea are a major cause of blindness worldwide, second only to cataract in overall importance. The epidemiology of corneal blindness is complicated and encompasses a wide variety of infectious and inflammatory eye diseses that cause corneal scarring, which ultimately leads to functional blindness. In addition, the prevalence of corneal disease varies from country to country and even from one population to another. While cataract is responsible for nearly 20 million of the 45 million blind people in the world, the next major cause is trachoma which blinds 4.9 million individuals, mainly as a result of corneal scarring and vascularization. Ocular trauma and corneal ulceration are significant causes of corneal blindness that are often underreported but may be responsible for 1.5-2.0 million new cases of monocular blindness every year. Causes of childhood blindness (about 1.5 million worldwide with 5 million visually disabled) include xerophthalmia (350,000 cases annually), ophthalmia neonatorum, and less frequently seen ocular diseases such as herpes simplex virus infections and vernal keratoconjunctivitis. Even though the control of onchocerciasis and leprosy are public health success stories, these diseases are still significant causes of blindness--affecting a quarter of a million individuals each. Traditional eye medicines have also been implicated as a major risk factor in the current epidemic of corneal ulceration in developing countries. Because of the difficulty of treating corneal blindness once it has occurred, public health prevention programmes are the most cost-effective means of decreasing the global burden of corneal blindness. PMID:11285665

  10. Effects of artificial tear treatment on corneal epithelial thickness and corneal topography findings in dry eye patients.

    PubMed

    Çakır, B; Doğan, E; Çelik, E; Babashli, T; Uçak, T; Alagöz, G

    2018-05-01

    To investigate the effects of artificial tear treatment on central corneal epithelial thickness, and central, mid-peripheral and peripheral corneal thicknesses in patients with dry eye disease (DED). Patients with DED underwent ocular examinations, including Schirmer-2 test, slit lamp examination for tear break-up time (BUT), corneal topography (CT) for measuring mean central, mid-peripheral and peripheral corneal thickness values and anterior segment optic coherence tomography (AS-OCT) for obtaining central corneal epithelial thickness. After artificial tear treatment (carboxymethylcellulose and sodium hyaluronate formulations) for one month, patients were examined again at a second visit and the results were compared. Sixty-one eyes of 33 female dry eye patients (mean age: 38.3±5.7 years) were enrolled. The mean follow-up time was 36.4±3.3 days. The mean tear BUT and Schirmer-1 tests revealed significant improvement after treatment (P=0.000, P=0.000, respectively). Central corneal epithelium and mean mid-peripheral corneal thicknesses measured significantly higher after treatment (P=0.001, P=0.02). Changes in central and peripheral corneal thicknesses were not statistically significant. Artificial tear treatment in dry eye patients seems to increase central corneal epithelial and mid-peripheral corneal thicknesses. Measurement of corneal epithelial thickness can be a useful tool for evaluation of treatment response in dry eye patients. Further long-term prospective studies are needed to investigate this item. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. Ciliary neurotrophic factor promotes the activation of corneal epithelial stem/progenitor cells and accelerates corneal epithelial wound healing.

    PubMed

    Zhou, Qingjun; Chen, Peng; Di, Guohu; Zhang, Yangyang; Wang, Yao; Qi, Xia; Duan, Haoyun; Xie, Lixin

    2015-05-01

    Ciliary neurotrophic factor (CNTF), a well-known neuroprotective cytokine, has been found to play an important role in neurogenesis and functional regulations of neural stem cells. As one of the most innervated tissue, however, the role of CNTF in cornea epithelium remains unclear. This study was to explore the roles and mechanisms of CNTF in the activation of corneal epithelial stem/progenitor cells and wound healing of both normal and diabetic mouse corneal epithelium. In mice subjecting to mechanical removal of corneal epithelium, the corneal epithelial stem/progenitor cell activation and wound healing were promoted by exogenous CNTF application, while delayed by CNTF neutralizing antibody. In cultured corneal epithelial stem/progenitor cells, CNTF enhanced the colony-forming efficiency, stimulated the mitogenic proliferation, and upregulated the expression levels of corneal epithelial stem/progenitor cell-associated transcription factors. Furthermore, the promotion of CNTF on the corneal epithelial stem/progenitor cell activation and wound healing was mediated by the activation of STAT3. Moreover, in diabetic mice, the content of CNTF in corneal epithelium decreased significantly when compared with that of normal mice, and the supplement of CNTF promoted the diabetic corneal epithelial wound healing, accompanied with the advanced activation of corneal epithelial stem/progenitor cells and the regeneration of corneal nerve fibers. Thus, the capability of expanding corneal epithelial stem/progenitor cells and promoting corneal epithelial wound healing and nerve regeneration indicates the potential application of CNTF in ameliorating limbal stem cell deficiency and treating diabetic keratopathy. © 2014 AlphaMed Press.

  12. Topical Drug Formulations for Prolonged Corneal Anesthesia

    PubMed Central

    Wang, Liqiang; Shankarappa, Sahadev A.; Tong, Rong; Ciolino, Joseph B.; Tsui, Jonathan H.; Chiang, Homer H.; Kohane, Daniel S.

    2013-01-01

    Purpose Ocular local anesthetics (OLA’s) currently used in routine clinical practice for corneal anesthesia are short acting and their ability to delay corneal healing makes them unsuitable for long-term use. In this study, we examined the effect on the duration of corneal anesthesia of the site-1 sodium channel blocker tetrodotoxin (TTX), applied with either proparacaine or the chemical permeation enhancer OTAB. The effect of test solutions on corneal healing was also studied. Methods Solutions of TTX, proparacaine, and OTAB, singly or in combination were applied topically to the rat cornea. The blink response, an indirect measure of corneal sensitivity, was recorded using a Cochet-Bonnet esthesiometer, and the duration of corneal anesthesia calculated. The effect of test compounds on the rate of corneal epithelialization was studied in vivo following corneal debridement. Results Combination of TTX and proparacaine resulted in corneal anesthesia that was 8–10 times longer in duration than that from either drug administered alone, while OTAB did not prolong anesthesia. The rate of corneal healing was moderately delayed following co-administration of TTX and proparacaine. Conclusion Co-administration of TTX and proparacaine significantly prolonged corneal anesthesia but in view of delayed corneal re-epithelialization, caution is suggested in use of the combination. PMID:23615270

  13. Tracker-assisted versus manual ablation zone centration in laser in situ keratomileusis for myopia and astigmatism.

    PubMed

    Pineros, Oscar E

    2002-01-01

    Eye tracker systems have been developed concomitantly with small scanning beams to theoretically reduce ablation zone decentration and for accurate registration of all the laser pulses on the cornea. The purpose of the study was to compare the tracker-assisted with the manual centration method. Twenty-five patients (48 eyes) with myopia and/or astigmatism had laser in situ keratomileusis (LASIK) between August 1998 and February 1999 with the Technolas 117C laser. Twenty patients (38 eyes, 80%) were available for follow-up at 3 months after surgery. Eyes were assigned randomly to one of two ablation zone centration methods: Group 1: Tracker-assisted (20 eyes), Group 2: Manual (18 eyes). Mean distance between the ablation zone center and the pupillary center in the tracker-assisted centration group was 0.55 +/- 0.30 mm (range, 0.10 to 1.4 mm), and in the manual centration group, 0.43 +/- 0.23 mm (range, 0.10 to 1.0 mm) (P = .177). There was no statistically significant difference in postoperative contrast sensitivity, glare, and Topographical Corneal Surface Regularity Index (SRI) between the two groups. We obtained good results with both centration methods. We did not find superiority of the tracker-assisted over manual regarding ablation zone centration, vision quality, or regularity of the ablation.

  14. Corneal surface temperature change as the mode of stimulation of the non-contact corneal aesthesiometer.

    PubMed

    Murphy, P J; Morgan, P B; Patel, S; Marshall, J

    1999-05-01

    The non-contact corneal aesthesiometer (NCCA) assesses corneal sensitivity by using a controlled pulse of air, directed at the corneal surface. The purpose of this paper was to investigate whether corneal surface temperature change was a component in the mode of stimulation. Thermocouple experiment: A simple model corneal surface was developed that was composed of a moistened circle of filter paper placed on a thermocouple and mounted on a glass slide. The temperature change produced by different stimulus pressures was measured for five different ambient temperatures. Thermal camera experiment: Using a thermal camera, the corneal surface temperature change was measured in nine young, healthy subjects after exposure to different stimulus air pulses. Pulse duration was set at 0.9 s but was varied in pressure from 0.5 to 3.5 millibars. Thermocouple experiment: An immediate drop in temperature was detected by the thermocouple as soon as the air flow was incident on the filter paper. A greater temperature change was produced by increasing the pressure of the incident air flow. A relationship was found and a calibration curve plotted. Thermal camera experiment: For each subject, a drop in surface temperature was detected at each stimulus pressure. Furthermore, as the stimulus pressure increased, the induced reduction in temperature also increased. A relationship was found and a calibration curve plotted. The NCCA air-pulse stimulus was capable of producing a localized temperature change on the corneal surface. The principal mode of corneal nerve stimulation, by the NCCA air pulse, was the rate of temperature change of the corneal surface.

  15. Contact lens management of irregular corneas after traumatic aphakia: A pediatric case series.

    PubMed

    Aung, Yin-Yin; McLeod, Andrew

    2015-10-01

    Pediatric patients account for 35% of all cases that present after ocular trauma and 20.9% of those result in a ruptured globe. When repairing the globe, the removal of the natural lens results in a significant change in refractive error and loss of accommodation. In addition, the eye can have scarring, irregular astigmatism, and changes to the ocular surface. Treatment and vision rehabilitation should be aggressive and done quickly to prevent amblyopia. Advanced lens designs are often needed to treat both the irregular ocular surface and the aphakia. Treatment options are often confounded with the usual issues of contact lens compliance, intolerance, and complications. This case series follows three aphakic pediatric patients through the contact lens fitting process after sustaining a ruptured globe that left them aphakic with residual irregular astigmatism and corneal scarring. Patient 1 is a 3-year-old Hispanic male fit with a bitoric gas permeable contact lens with irregular astigmatism and an elevated central corneal scarring. Patient 2 is a 12-year-old Caucasian male with minimal residual astigmatism fit in a multifocal soft contact lens. Patient 3 is an 8-year-old African American male fit with a hybrid contact lens that was needed to vault the irregular astigmatism and central corneal scarring. Treating patients with irregular corneas or aphakia can be challenging in their own right, but in combination are some of the most advanced specialty contact lens fittings. This case series followed three pediatric patients through the fitting process and demonstrated the options and challenges when fitting this unique patient population. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Combined intrastromal astigmatic keratotomy and laser in situ keratomileusis flap followed by photoablation to correct post-penetrating keratoplasty ametropia and high astigmatism: One-year follow-up.

    PubMed

    Shalash, Riad B; Elshazly, Malak I; Salama, Marwa M

    2015-10-01

    To evaluate a new technique combining intrastromal astigmatic keratotomy (AK) with a laser in situ keratomileusis (LASIK) flap followed by excimer laser photoablation to correct post-penetrating keratoplasty (PKP) high astigmatism and ametropia. Kasr El Aini Hospital, Cairo University, Cairo, Egypt. Prospective interventional uncontrolled case series. Patients with post-PKP high astigmatism and ametropia had paired intrastromal AK with LASIK flap using the M2 microkeratome followed 2 to 3 months later by excimer laser photoablation. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), mean refractive spherical equivalent (SE), and mean cylinder after each step and at the 1-year follow-up. The study comprised 20 eyes (20 patients). All parameters were significantly improved in all patients by the last follow-up visit. The mean UDVA improved from 1.07 logMAR ± 0.2 (SD) preoperatively to 0.23 ± 0.18 logMAR (P < .001), the mean CDVA improved from 0.79 ± 0.18 logMAR to 0.12 ± 0.12 logMAR (P < .001), the mean refractive SE improved from -5.04 ± 2.62 diopters (D) to -1.47 ± 1.32 D (P = .001), and the mean cylinder reduced from -5.39 ± 0.98 D to -1.05 ± 0.71 D (P < .001). The mean correction index was 0.84 ± 0.10, and the mean flattening index was 0.83 ± 0.10. Thirty-five percent of cases developed microperforations, and 15% developed epithelial ingrowth. This combined approach allowed for the correction of high astigmatism and ametropia following PKP; however, epithelial ingrowth requiring intervention is a complication to be considered. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Evaluation of Biomechanical Changes in Myopia Patients with Unsatisfactory Corneas After Femto Second-Laser In Situ Keratomileusis (FS-LASIK) Concurrent with Accelerated Corneal Collagen Cross-Linking Using Corvis-ST: Two-Year Follow-Up Results.

    PubMed

    Xu, Weiwei; Tao, Ye; Wang, Liqiang; Huang, Yifei

    2017-07-27

    BACKGROUND Some myopia patients with unsatisfactory corneas consider corneal refractive surgery for different reasons. Accelerated corneal collagen crosslinking (ACXL) is an effective method to enhance the resistance of the cornea. The present investigation was designed to evaluate the changes of biomechanical properties in patients with myopia and thin corneas after femtosecond-laser in situ keratomileusis (FS-LASIK) concurrent with ACXL. MATERIAL AND METHODS A prospective study was designed. A total of 22 eyes of 11 myopia astigmatism patients with unsatisfactory corneas were enrolled. The patients were assigned to femtosecond-laser in situ keratomileusis concurrent with accelerated corneal collagen crosslinking (FS-LASIK-ACXL). The follow-up duration was 24 months. Manifest refraction, uncorrected (UDVA), and corrected distance visual acuity (CDVA), ultra-high-speed camera (Corvis-ST), corneal topography, anterior segment OCT (AS-OCT), Pentacam, and endothelial cell density (ECD) were examined before and after the operation. The corneal biomechanical and refractive data was analyzed using SAS9.3. Data were analyzed through normal distribution test and variance of analysis. The difference was considered as statistically significant when p<0.05. RESULTS The steep K (Ks) values, flat K (Kf) values, average keratometry values (Avek) values, and central corneal thickness (CCT) declined significantly after FS-LASIK-ACXL operation. The values of first applanation length (A1L), the second applanation length (A2L), the first applanation velocity (A1V), the second applanation velocity (A2V), deformation amplitude (DA), highest concavity peak distance (PD), and radius of curvature at the time of highest concavity (HCR) did not show significant difference after the operation. CONCLUSIONS FS-LASIK-ACXL is an effective and safe surgery for improving visual acuity for myopic patients with thin corneas, and it does not increase the risk of iatrogenic keratectasia.

  18. Risk Factors for Astigmatism in Preschool Children: The Multi-Ethnic Pediatric Eye Disease and Baltimore Pediatric Eye Disease Studies

    PubMed Central

    Tarczy-Hornoch, Kristina; Varma, Rohit; Cotter, Susan A.; McKean-Cowdin, Roberta; Lin, Jesse H.; Borchert, Mark S.; Torres, Mina; Wen, Ge; Azen, Stanley P.; Tielsch, James M.; Friedman, David S.; Repka, Michael X.; Katz, Joanne; Giordano, Lydia; Ibironke, Josephine

    2011-01-01

    Objective To evaluate risk factors for astigmatism in a population-based sample of preschool children. Design Population-based cross-sectional study Participants Population-based samples of 9970 children ages 6 to 72 months from Los Angeles County, California, and Baltimore, Maryland. Methods A cross-sectional study of children participating in the Multiethnic Pediatric Eye Disease Study and the Baltimore Eye Disease Study was completed. Data were obtained by clinical examination or by in-person interview. Odds ratios and 95% confidence intervals (95%CI) were calculated to evaluate potential associations between clinical, behavioral, or demographic factors and astigmatism. Main Outcome Measures Odds ratios (ORs) for various risk factors associated with astigmatism. Results Participants with myopia (≤−1.0 diopters) were 4.6 times more likely to have astigmatism (95%CI 3.56, 5.96) than those without refractive error, while participants with hyperopia (≥+2.00 diopters) were 1.6 times more likely (95%CI 1.39, 1.94). Children 6 months to <12 months of age were approximately 3 times more likely to have astigmatism than children 5 to 6 years of age (95%CI 2.28, 3.73). Both Hispanic (OR=2.38) and African-American (OR=1.47) children were more likely to have astigmatism than non-Hispanic white children. Further, children whose mothers smoked during pregnancy were 1.46 times (95% CI 1.14, 1.87) more likely to have astigmatism than children whose mothers did not smoke. Conclusions In addition to infancy, Hispanic and African-American race/ethnicity and correctable/modifiable risk factors such as myopia, hyperopia, and maternal smoking during pregnancy are associated with a higher risk of having astigmatism. While the prevalence of smoking during pregnancy is typically low, this association may suggest etiologic pathways for future investigation. PMID:21856010

  19. Corneal Toxicity Following Exposure to Asclepias Tuberosa

    PubMed Central

    Mikkelsen, Lauge Hjorth; Hamoudi, Hassan; Gül, Cigdem Altuntas; Heegaard, Steffen

    2017-01-01

    Purpose: To present a case of corneal toxicity following exposure to milky plant latex from Asclepias tuberosa. Methods: A 70-year-old female presented with blurred vision and pain in her left eye after handling an Ascepias tuberosa. Clinical examination revealed a corneal stromal oedema with small epithelial defects. The corneal endothelium was intact and folds in Descemets membrane were observed. The oedema was treated with chloramphenicol, dexamethasone and scopolamine. Results: The corneal oedema had appeared after corneal exposure to the plant, Asclepias tuberosa, whose latex contains cardenolides that inhibit the Na+/ K+-ATPase in the corneal endothelium. The oedema resolved after 96 hours. After nine months the best corrected visual acuity was 20/20. Conclusion: Corneal toxicity has previously been reported for plants of the Asclepias family. This is a rare case describing severe corneal toxicity caused by exposure to latex from Asclepias tuberosa. Handling of plants of the Asclepias family should be kept as a differential diagnosis in cases of acute corneal toxicity. PMID:28400886

  20. Corneal Toxicity Following Exposure to Asclepias Tuberosa.

    PubMed

    Mikkelsen, Lauge Hjorth; Hamoudi, Hassan; Gül, Cigdem Altuntas; Heegaard, Steffen

    2017-01-01

    To present a case of corneal toxicity following exposure to milky plant latex from Asclepias tuberosa. A 70-year-old female presented with blurred vision and pain in her left eye after handling an Ascepias tuberosa . Clinical examination revealed a corneal stromal oedema with small epithelial defects. The corneal endothelium was intact and folds in Descemets membrane were observed. The oedema was treated with chloramphenicol, dexamethasone and scopolamine. The corneal oedema had appeared after corneal exposure to the plant, Asclepias tuberosa , whose latex contains cardenolides that inhibit the Na + / K + -ATPase in the corneal endothelium. The oedema resolved after 96 hours. After nine months the best corrected visual acuity was 20/20. Corneal toxicity has previously been reported for plants of the Asclepias family. This is a rare case describing severe corneal toxicity caused by exposure to latex from Asclepias tuberosa . Handling of plants of the Asclepias family should be kept as a differential diagnosis in cases of acute corneal toxicity.