Sample records for keratoplasty dsaek triple

  1. A Randomized Multicenter Clinical Trial of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) versus DSAEK.

    PubMed

    Dickman, Mor M; Kruit, Pieter J; Remeijer, Lies; van Rooij, Jeroen; Van der Lelij, Allegonda; Wijdh, Robert H J; van den Biggelaar, Frank J H M; Berendschot, Tos T J M; Nuijts, Rudy M M A

    2016-11-01

    To compare visual acuity, refraction, endothelial cell density (ECD), and complications after Descemet stripping automated endothelial keratoplasty (DSAEK) and ultrathin DSAEK (UT-DSAEK). A multicenter, prospective, double-masked, randomized, controlled clinical trial. From 66 patients with irreversible corneal endothelial dysfunction dues to Fuchs' dystrophy who enrolled from 4 tertiary medical centers in the Netherlands, 66 eyes were studied. Participants were centrally randomized to undergo either UT-DSAEK or DSAEK, based on preoperative best spectacle-corrected visual acuity (BSCVA), recipient central corneal thickness, patient age, and recruitment center. Donor corneas were precut by a single cornea bank. Participants underwent ophthalmic examinations preoperatively and 3, 6, and 12 months after the operation, including manifest refraction, BSCVA using an Early Treatment Diabetic Retinopathy Study chart, and endothelium imaging. BSCVA 12 months postoperatively. Preoperative BSCVA did not differ between patients undergoing DSAEK (0.35 logarithm of the minimum angle of resolution [logMAR] [95% confidence interval {CI} 0.27-0.43]; n = 32) and UT-DSAEK (0.37 logMAR [95% CI 0.31-0.43]; n = 34; P = 0.8). BSCVA was significantly better after UT-DSAEK compared with that after DSAEK at 3 months (0.17 logMAR [95% CI 0.13-0.21], n = 31 vs. 0.28 logMAR [95% CI 0.23-0.33], n = 31; P = 0.001), 6 months (0.14 logMAR [95% CI 0.10-0.18], n = 30 vs. 0.24 logMAR [95% CI 0.20-0.28], n = 30; P = 0.002), and 12 months (0.13 logMAR [95% CI 0.09-0.17], n = 33 vs. 0.20 logMAR [95% CI 0.15-0.25], n = 29; P = 0.03). Refraction, ECD loss (40% at 3 months; P < 0.001), donor loss (DSAEK n = 2 vs. UT-DSAEK n = 3 [relative risk {RR} 1.4 {95% CI 0.24-7.5}; P = 0.7]), and graft dislocation (DSAEK n = 5 vs. UT-DSAEK n = 5 [RR 1.0 {95% CI 0.34-3.33}; P = 0.9]) did not differ between UT-DSAEK and DSAEK. Donor thickness was significantly thinner for UT-DSAEK (101 μm [95% CI 93

  2. Histologically proven epithelial ingrowth in failed Descemet stripping automated endothelial keratoplasty (DSAEK) managed by repeat DSAEK

    PubMed Central

    Ghosh, Saurabh; Bonshek, Richard; Morgan, Stephen J

    2013-01-01

    Purpose To report a case of corneal graft failure due to epithelial ingrowth after an uneventful combined Descemet stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification cataract surgery with intraocular lens implant treated successfully with a repeat DSAEK. Methods A 77-year-old male patient underwent combined DSAEK and phacoemulsification with intraocular lens implant implantation for Fuchs’ endothelial dystrophy plus cataract in the right eye. The donor cornea was cut on the Moria ALTK system and introduced using a suture pull-through technique. After an episode of endothelial rejection, the graft failed, with signs suggesting epithelial ingrowth. It was stripped from the host cornea using a Descemet’s membrane stripper, and a Simcoe irrigation-aspiration cannula was used to remove all traces of interface material. The excised lenticule was examined histologically using a hematoxylin and eosin stain. Result The patient regained and maintained excellent visual acuity with no sign of recurrence of epithelial ingrowth. Histopathological evaluation of the donor tissue of the first graft showed epithelial ingrowth on the stromal surface of the graft and very few endothelial cells, in keeping with the diagnosis of graft failure. Conclusion Epithelial ingrowth is a possible cause of endothelial graft failure, but histologically proven cases are rare. Surgical intervention can achieve successful clearance, with the potential for cure and an excellent outcome. PMID:23754868

  3. [Effect of donor graft characteristics on clinical outcomes in Descemet stripping automated endothelial keratoplasty (DSAEK)].

    PubMed

    Ho Wang Yin, G; Sampo, M; Soare, S; Hoffart, L

    2017-01-01

    The purpose of our study was to evaluate the progression of lamellar corneal grafts after endothelial keratoplasty by Descemet stripping automated endothelial keratoplasty (DSAEK) and the effect of their characteristics on the clinical and functional results. This was a prospective study in which 74 patients who had undergone endothelial keratoplasty by DSAEK were included. The corneal grafts were obtained from a French tissue bank and were delivered in a preservation medium containing a deturgescent agent (Corneajet ® or Stemalpha 3 ® ). Pachymetry of the corneal graft was measured ex vivo by ultrasonic pachymetry prior to dissection, then after the 1st or 2 nd cut as necessary. Corrected visual acuity in logMAR, total graft pachymetry, measured by anterior segment OCT (Spectralis ® HRA+SDOCT, Heidelberg engineering, Inc., Heidelberg, Germany) and corneal density (Pentacam ® , Oculus, Inc., Wetzlar, Germany) were obtained for each patient preoperatively, at D5, M1, M3, M6, M9 and M12. Overall, 74 corneal grafts, from donors of mean age 69.7±13.3 years (37 to 92 years) were transplanted into 67 patients aged 70.3±12.1 years. Predissection pachymetry was statistically significantly thicker in the case of short deturgescence time (r=-0.383, P=0.001). For the same deturgescence time, predissection pachymetry was statistically significantly thicker in the Stemalpha 3 ® medium (691±89μm for Corneajet ® vs. 760±100μm for Stemalpha 3 ® , P=0.01), with the same final pachymetry (168±31μm vs. 166±25μm, P=0.833). Graft pachymetry and total corneal pachymetry decreased significantly between the preoperative measurement and M12 (168±29μm vs. 92±57μm, P=0.0008 et 665±124μm vs. 566±73μm, P=0.027 respectively). Preoperative endothelial cell density (2938±418 cells/mm 2 ) did not correlate with postoperative visual acuity. There was a positive correlation between visual acuity at D5 and donor age (r=0.3, P=0.04). Postoperative visual acuity

  4. Iris alterations after DSAEK.

    PubMed

    Del Hierro Zarzuelo, A; Boto de Los Bueis, A

    2016-09-01

    To evaluate a series of case that developed iris changes after performing Descemet's stripping automated endothelial keratoplasty (DSAEK). Retrospective study of eyes that developed iris abnormalities, such as pupil ovalisation, iris atrophy, iridocorneal synechiae, mydriatic pupil, and pigmentary changes after performing DSAEK in a tertiary hospital. In a series of the first 32 DSAEK procedures performed, new single or mixed iris alterations were observed in 12 eyes (37.5%). Iris-corneal synechiae were observed in 7 eyes, corectopias in 9 eyes, iris atrophy in 3 cases, and one case developed an areflexic mydriatic pupil. Long-term pigment dispersion at the edge of the lenticule was observed in 12 eyes. The alterations occurred after three months from the surgery. In the evaluation of the associated factors, malignant glaucoma had occurred in 1 case, 2 eyes had required a second surgery, one case by re-DSAEK, and the other one by removing the intraocular lens due to lens opacification. Two cases had a shallow anterior chamber. No relationship was found between the thickness of the peripheral lenticule and the presence of synechiae. Iris changes regarding DSAEK are possible. A discussion is presented on the relationship between increased intraocular pressure due to air in anterior chamber and its relationship with ischaemia and secondary alterations in the iris. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  5. Five-Year Graft Survival Comparing Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty.

    PubMed

    Ang, Marcus; Soh, Yuqiang; Htoon, Hla Myint; Mehta, Jodhbir S; Tan, Donald

    2016-08-01

    To compare 5-year graft survival after Descemet stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK) in Asian eyes. Prospective, nested, cohort study. Consecutive patients who underwent DSAEK (423 eyes) or PK (405 eyes) for Fuchs' endothelial dystrophy (FED) or bullous keratopathy (BK). Clinical data and donor and recipient characteristics were recorded from our prospective cohort from the Singapore Corneal Transplant Registry. All surgeries were performed by the corneal surgeons at our center, which included cases performed or partially performed by corneal fellows in training under direct supervision. Five-year cumulative graft survival. Overall mean age was 67.8±9.8 years, and 50.1% of patients were men. There were no significant differences in age (P = 0.261) or gender (P = 0.78) between PK and DSAEK groups in our predominantly Chinese (76.6%) Asian cohort, with more BK compared with FED (68.1% vs. 31.9%; P < 0.001). Overall 5-year graft survival was superior for DSAEK compared with PK (79.4% vs. 66.5%; P < 0.001, log-rank test). Median 5-year percent endothelial cell density loss was significantly greater in PK compared with DSAEK (60.9% vs. 48.7%; P = 0.007). Cox regression analysis revealed that BK was a significant factor associated with graft failure (hazard ratio [HR], 3.30; 95% confidence interval [CI], 2.05-5.33; P < 0.001), and PK was more likely to fail compared with endothelial keratoplasty (HR, 1.61; 95% CI, 1.08-2.41; P = 0.02) adjusting for confounders such as recipient age, gender, and donor factors. Five-year cumulative incidence of complications such as graft rejection (P < 0.001), epitheliopathy (P < 0.001), suture-related corneal infections (P < 0.001), and wound dehiscence (P = 0.002) were greater in the PK group compared with the DSAEK group. In Asian eyes from the same study cohort with standardized surgical and postoperative regimes, 5-year graft survival was superior for DSAEK compared with

  6. Graft survival of diabetic versus nondiabetic donor tissue after initial keratoplasty.

    PubMed

    Vislisel, Jesse M; Liaboe, Chase A; Wagoner, Michael D; Goins, Kenneth M; Sutphin, John E; Schmidt, Gregory A; Zimmerman, M Bridget; Greiner, Mark A

    2015-04-01

    To compare corneal graft survival using tissue from diabetic and nondiabetic donors in patients undergoing initial Descemet stripping automated endothelial keratoplasty (DSAEK) or penetrating keratoplasty (PKP). A retrospective chart review of pseudophakic eyes that underwent DSAEK or PKP was performed. The primary outcome measure was graft failure. Cox proportional hazard regression and Kaplan-Meier survival analyses were used to compare diabetic versus nondiabetic donor tissue for all keratoplasty cases. A total of 183 eyes (136 DSAEK, 47 PKP) were included in the statistical analysis. Among 24 procedures performed using diabetic donor tissue, there were 4 cases (16.7%) of graft failure (3 DSAEK, 1 PKP), and among 159 procedures performed using nondiabetic donor tissue, there were 18 cases (11.3%) of graft failure (12 DSAEK, 6 PKP). Cox proportional hazard ratio of graft failure for all cases comparing diabetic with nondiabetic donor tissue was 1.69, but this difference was not statistically significant (95% confidence interval, 0.56-5.06; P = 0.348). There were no significant differences in Kaplan-Meier curves comparing diabetic with nondiabetic donor tissue for all cases (P = 0.380). Statistical analysis of graft failure by donor diabetes status within each procedure type was not possible because of the small number of graft failure events involving diabetic tissue. We found similar rates of graft failure in all keratoplasty cases when comparing tissue from diabetic and nondiabetic donors, but further investigation is needed to determine whether diabetic donor tissue results in different graft failure rates after DSAEK compared with PKP.

  7. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK).

    PubMed

    Koenig, Steven B; Covert, Douglas J; Dupps, William J; Meisler, David M

    2007-07-01

    To evaluate visual acuity, refractive outcomes, and endothelial cell density 6 months after Descemet stripping and automated endothelial keratoplasty (DSAEK). We performed an institutional review board-approved prospective study of a surgical case series of 34 patients at 2 institutions undergoing DSAEK for Fuchs endothelial dystrophy, pseudophakic bullous keratopathy, or aphakic bullous keratopathy with or without simultaneous phacoemulsification and intraocular lens implantation. Clinical outcomes, including best spectacle-corrected visual acuity (BSCVA), spherical equivalent refraction, and refractive astigmatism and topographic or keratometric astigmatism, were assessed at the 6-month postoperative examination and compared with preoperative values with paired Student t tests. The change in endothelial cell density from the eye bank examination to 6 months after transplantation was similarly evaluated. BSCVA averaged 20/99 preoperatively and 20/42 postoperatively (P < 0.0001). After DSAEK, 30 (88.2%) of 34 patients showed improved BSCVA, and 21 (61.8%) of the 34 patients achieved a BSCVA of 20/40 or better. For patients not undergoing simultaneous phacoemulsification and intraocular lens implantation, a hyperopic shift in refraction of 1.19 +/- 1.32 D was noted. Refractive astigmatism, topographic astigmatism, and keratometry showed no statistically significant change. Endothelial cell density of donor corneas averaged 2826 +/- 370 cells/mm, whereas the mean postoperative density was 1396 +/- 440 cells/mm. This finding corresponded to an average loss of 1426 cells/mm (50% loss; P = 0.0001). The first half of cases experienced an average cell loss of 1674 cells/mm (59% loss) compared with 1181 (41% loss) in the second half of cases (P = 0.005). Three (9%) of 34 grafts experienced iatrogenic graft failure and required reoperation with new donor tissue. Also, 9 (27%) of 34 grafts experienced dislocation in the early postoperative period and required repositioning

  8. Meta-Analysis of Postoperative Outcome Parameters Comparing Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty.

    PubMed

    Pavlovic, Ivana; Shajari, Mehdi; Herrmann, Eva; Schmack, Ingo; Lencova, Anna; Kohnen, Thomas

    2017-12-01

    This meta-analysis compares Descemet membrane endothelial keratoplasty (DMEK) with Descemet stripping automated endothelial keratoplasty (DSAEK) to evaluate their strength and weakness profiles. Meta-analysis. We performed a meta-analysis and searched the peer-reviewed literature in PubMed, Cochrane Library, Web of Science, and Embase following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Prospective and retrospective trials performing and comparing DMEK and DSAEK were included. Effects were calculated as odds ratios or standardized mean differences. A total of 11 studies with a total of 723 eyes (350 DMEK and 373 DSAEK) were included. No significant difference was found regarding the total detachment rate, graft failure, and rejection. One of 340 eyes undergoing DMEK showed total detachment and 5 of 363 eyes undergoing DSAEK showed total detachment (P = 0.28). Six of 280 eyes undergoing DMEK showed graft failure; 1 of 313 eyes undergoing DSAEK developed this complication (P = 0.18). No rejection was observed in 158 eyes undergoing DMEK; 4 cases of rejection occurred in 196 eyes undergoing DSAEK (P = 0.37). No significant difference was found regarding endothelial cell loss (P = 0.48). There was a significantly higher partial detachment rate with DMEK: 88 of 340 eyes undergoing DMEK showed partial detachment; 16 of 363 eyes undergoing DSAEK showed this complication (P < 0.00001). DMEK was superior in best-corrected visual acuity after 6 months (P < 0.001), subjective evaluation of visual acuity (P = 0.001), patient satisfaction (P < 0.001), and was the method preferred by patients (P = 0.001). DMEK and DSAEK have a similar complication profile. However, the superiority in the visual outcome and patient satisfaction makes DMEK the preferred option for most patients.

  9. Descemet’s Stripping Automated Endothelial Keratoplasty Outcomes Compared with Penetrating Keratoplasty from the Cornea Donor Study

    PubMed Central

    Price, Marianne O.; Gorovoy, Mark; Benetz, Beth A.; Price, Francis W.; Menegay, Harry J.; Debanne, Sara M.; Lass, Jonathan H.

    2010-01-01

    Purpose To assess outcomes 1 year after Descemet’s stripping automated endothelial keratoplasty (DSAEK) in comparison with penetrating keratoplasty (PKP) from the Specular Microscopy Ancillary Study (SMAS) of the Cornea Donor Study. Design Multicenter, prospective, nonrandomized clinical trial. Participants A total of 173 subjects undergoing DSAEK for a moderate risk condition (principally Fuchs’ dystrophy or pseudophakic/aphakic corneal edema) compared with 410 subjects undergoing PKP from the SMAS who had clear grafts with at least 1 postoperative specular image within a 15-month follow-up period. Methods The DSAEK procedures were performed by 2 experienced surgeons per their individual techniques, using the same donor and similar recipient criteria as for the PKP procedures in the SMAS performed by 68 surgeons at 45 sites, with donors provided from 31 eye banks. Graft success and complications for the DSAEK group were assessed and compared with the SMAS group. Endothelial cell density (ECD) was determined from baseline donor, 6-month (range, 5–7 months), and 12-month (range, 9–15 months) postoperative central endothelial images by the same reading center used in the SMAS. Main Outcome Measures Endothelial cell density and graft survival at 1 year. Results Although the DSAEK recipient group criteria were similar to the PKP group, Fuchs’ dystrophy was more prevalent in the DSAEK group (85% vs. 64%) and pseudophakic corneal edema was less prevalent (13% vs. 32%, P<0.001). The regraft rate within 15 months was 2.3% (DSAEK group) and 1.3% (PKP group) (P = 0.50). Percent endothelial cell loss was 34±22% versus 11±20% (6 months) and 38±22% versus 20±23% (12 months) in the DSAEK and PKP groups, respectively (both P<0.001). Preoperative diagnosis affected endothelial cell loss over time; in the PKP group, the subjects with pseudophakic/aphakic corneal edema experienced significantly higher 12-month cell loss than the subjects with Fuchs’ dystrophy (28% vs

  10. [Confocal microscopy findings after endothelial transplant by DSAEK].

    PubMed

    Ramírez, Manuel; Ortiz, Claudia; Dewit-Carter, Guillermo; Hernández-Quintela, Everardo

    2018-01-01

    To evaluate early in vivo corneal wound healing findings after Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) by using in vivo confocal microscopy. A total of 15 eyes of 15 patients were included. In vivo confocal microscopy (Confoscan 4, Fortune Technologies, Italy) was performed from 4 to 7 weeks after DSAEK. Measurements were scanned from the corneal endothelium to the corneal surface with a Navis® software (NIDEK, Multi-Instrument Diagnostic System, Japan). Donor-receptor interface was found in an average of 114 ± 12.4 microns. Corneal stromal folds were observed from 111.1 ± 3.5 microns from the endothelium to 286 ± 94 microns (mean 175 ± 90.5 microns of the corneal stroma). Keratocites were activated in the donor tissue from 12 ± 1.4 microns from the endothelium to 105 ± 38.2 microns (mean 93 ± 36.9 microns of the corneal stroma). Donor keratocites are activated up to 7 weeks after DSAEK. Several corneal folds are present in proximity to the donor-receptor interface after DSAEK. Further evaluation of these findings is justified to determine its clinical significance. Copyright: © 2018 Permanyer.

  11. Descemet stripping automated endothelial keratoplasty 3-year graft and endothelial cell survival compared with penetrating keratoplasty

    PubMed Central

    Price, Marianne O.; Gorovoy, Mark; Price, Francis W.; Benetz, Beth A.; Menegay, Harry J.; Lass, Jonathan H.

    2012-01-01

    Purpose To assess 3-year outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) in comparison with penetrating keratoplasty (PKP) from the Cornea Donor Study (CDS). Design Prospective, multicenter, nonrandomized clinical trial. Participants A total of 173 subjects undergoing DSAEK for a moderate risk condition (principally Fuchs’ dystrophy or pseudophakic corneal edema) compared with 1101 subjects undergoing PKP from the CDS. Methods The DSAEK procedures were performed by two experienced surgeons using the same donor and similar recipient criteria as for the CDS PKP procedures, performed by 68 surgeons. Graft success was assessed by Kaplan Meier survival analysis. Central endothelial cell density (ECD) was determined from baseline donor and postoperative central endothelial images by the reading center used in the CDS Specular Microscopy Ancillary Study. Main Outcome Measures Graft clarity and endothelial cell density Results The donor and recipient demographics were comparable in the DSAEK and PKP groups, except the proportion of Fuchs’ dystrophy cases was higher in the DSAEK cohort. The 3-year survival rate did not differ significantly between DSAEK and PKP procedures performed for either Fuchs’ dystrophy (96% for both, P=0.81) or non-Fuchs cases (86% vs. 84%, respectively, P=0.41). Principal causes of graft failure/regraft within 3 years after DSAEK and PKP were immunologic graft rejection (0.6% vs. 3.1%), endothelial decompensation in the absence of documented rejection (1.7% vs 2.1%), unsatisfactory visual or refractive outcome (1.7% vs. 0.5%), and infection (0% vs. 1.1%), respectively. The 3-year predicted probability of a rejection episode was 9% with DSAEK vs. 20% with PKP (P=0.0005). The median 3-year cell loss for DSAEK and PKP was 46% and 51%, respectively (P=0.33) in Fuchs’s dystrophy cases, and 59% and 61%, respectively (P=0.70), in the non-Fuchs’ cases. At 3 years, use of a smaller DSAEK insertion incision was associated

  12. Evolving indications for and trends in keratoplasty in British Columbia, Canada, from 2002 to 2011: a 10-year review.

    PubMed

    Tan, Johnson C H; Holland, Simon P; Dubord, Paul J; Moloney, Gregory; McCarthy, Martin; Yeung, Sonia N

    2014-03-01

    The aim of this study was to report the evolving indications for keratoplasty and the shift in the type of keratoplasty performed in British Columbia, Canada, over a 10-year period from 2002 to 2011. This was a retrospective database review of all the records of corneal transplant tissues at the Eye Bank of British Columbia, Canada, from January 2002 to December 2011. The patient demographics, indications, and types of transplant performed were analyzed. A total of 4843 corneal transplants were performed in 3742 patients (1968 male and 1774 female) from January 2002 to December 2011. The number of keratoplasties performed ranged from 420 in 2008 to 578 in 2011. The top 4 indications over the 10-year period were Fuchs endothelial dystrophy (FED; 18.9%), aphakic/pseudophakic bullous keratopathy (17.4%), regraft (17.1%), and keratoconus (15.5%). Penetrating keratoplasty (PKP) accounted for 86.5% (4191 transplants) of all keratoplasties performed. Since the introduction of Descemet stripping automated endothelial keratoplasty (DSAEK) in 2007, there was a significant increase in the number of DSAEKs (P < 0.0001) performed and a statistical decline in the number of PKPs (P < 0.0001) performed. Despite only 30 deep anterior lamellar keratoplasties being performed, an increasing trend was observed after 2008 (P = 0.0087). A decreasing trend in PKPs and an increasing trend in DSAEKs were observed for surgeries performed for FED, aphakic/pseudophakic bullous keratopathy, and regraft. FED has become the top indication for performing a keratoplasty over the 10-year period. There was a shift from PKP to DSAEK performed for endothelial failure. Although the number of deep anterior lamellar keratoplasty surgeries was small, there was a significant increasing trend.

  13. Corneal donor tissue preparation for endothelial keratoplasty.

    PubMed

    Woodward, Maria A; Titus, Michael; Mavin, Kyle; Shtein, Roni M

    2012-06-12

    Over the past ten years, corneal transplantation surgical techniques have undergone revolutionary changes. Since its inception, traditional full thickness corneal transplantation has been the treatment to restore sight in those limited by corneal disease. Some disadvantages to this approach include a high degree of post-operative astigmatism, lack of predictable refractive outcome, and disturbance to the ocular surface. The development of Descemet's stripping endothelial keratoplasty (DSEK), transplanting only the posterior corneal stroma, Descemet's membrane, and endothelium, has dramatically changed treatment of corneal endothelial disease. DSEK is performed through a smaller incision; this technique avoids 'open sky' surgery with its risk of hemorrhage or expulsion, decreases the incidence of postoperative wound dehiscence, reduces unpredictable refractive outcomes, and may decrease the rate of transplant rejection. Initially, cornea donor posterior lamellar dissection for DSEK was performed manually resulting in variable graft thickness and damage to the delicate corneal endothelial tissue during tissue processing. Automated lamellar dissection (Descemet's stripping automated endothelial keratoplasty, DSAEK) was developed to address these issues. Automated dissection utilizes the same technology as LASIK corneal flap creation with a mechanical microkeratome blade that helps to create uniform and thin tissue grafts for DSAEK surgery with minimal corneal endothelial cell loss in tissue processing. Eye banks have been providing full thickness corneas for surgical transplantation for many years. In 2006, eye banks began to develop methodologies for supplying precut corneal tissue for endothelial keratoplasty. With the input of corneal surgeons, eye banks have developed thorough protocols to safely and effectively prepare posterior lamellar tissue for DSAEK surgery. This can be performed preoperatively at the eye bank. Research shows no significant difference in

  14. Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices

    PubMed Central

    Khan, Salman Nasir; Shiakolas, Panos S.; Mootha, Venkateswara Vinod

    2015-01-01

    This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK. PMID:27051492

  15. Factors affecting DSAEK graft lenticle adhesion: an in vitro experimental study.

    PubMed

    Vaddavalli, Pravin K; Diakonis, Vasilios F; Canto, Ana P; Kankariya, Vardhaman P; Pappuru, Rajeev R; Ruggeri, Marco; Banitt, Michael R; Kymionis, George D; Yoo, Sonia H

    2014-06-01

    The aim of this study was to evaluate different factors that affect Descemet stripping automated endothelial keratoplasty (DSAEK) donor graft lenticle adhesion to the recipient cornea. This experimental study included 10 eye bank recipient corneas and 10 donor DSAEK lenticles. Recipient corneas were mounted on an artificial anterior chamber (AC), whereas donor lenticles were placed beneath the host cornea. Using optical coherence tomography and imaging software, the interface gap (IG) between the donor and recipient cornea was quantified to evaluate the effect of variations in AC air fill pressure, AC air fill duration, corneal massage, and corneal venting incisions on DSAEK donor graft lenticle adhesion. Different intraocular pressures (IOP) under air for the same time intervals, do not significantly correlate with the IG; nevertheless, it was noticed that the IG decreases as the IOP increases. With respect to the magnitude of AC IOP, there was no statistically significant difference when comparing 10 mm Hg with 30 mm Hg and assessing IG (P = 0.4). Complete air-fluid exchange resulted in significantly higher IG when compared with AC air bubble of 10 and 30 mm Hg that was sustained for 1 hour (P < 0.05). Furthermore, corneal surface massage did not facilitate DSAEK graft adhesion (P = 0.59). Finally, paracentral venting incisions followed by interface fluid aspiration seemed to significantly decrease the IG (P = 0.014). Corneal venting incisions and higher AC IOP values seem to facilitate DSAEK donor graft lenticle adhesion to the recipient cornea.

  16. Descemet Stripping Automated Endothelial Keratoplasty for Failed Penetrating Keratoplasty: Influence of the Graft-Host Junction on the Graft Survival Rate.

    PubMed

    Omoto, Takashi; Sakisaka, Toshihiro; Toyono, Tetsuya; Yoshida, Junko; Shirakawa, Rika; Miyai, Takashi; Yamagami, Satoru; Usui, Tomohiko

    2018-04-01

    To investigate the clinical results of Descemet stripping automated endothelial keratoplasty (DSAEK) for failed penetrating keratoplasty (PK) and the influence of the graft-host junction (GHJ) on the graft survival rate. Data were retrospectively collected on patient demographics, visual outcomes, complications, and graft survival rate for 17 eyes of 16 patients who underwent DSAEK for failed PK. The graft survival rate was compared between the eyes when divided into a bump group and a well-aligned group according to the shape of the GHJ detected on anterior segment optical coherence tomography. The most common indication for initial PK was bullous keratopathy after glaucoma surgery (35.3%). Seven eyes (41.2%) were classified into the bump group and 10 eyes (58.8%) into the well-aligned group. The mean best-ever documented visual acuity (BDVA) after DSAEK was 0.33 logMAR. Postoperatively, almost 70% of eyes achieved a BDVA that was within 0.2 logMAR of their preoperative BDVA. Graft detachment occurred in 29.4% of eyes and primary graft failure in 17.6%. All primary failures occurred in the bump group. The cumulative graft survival rate was 82.3% at 1 year, 73.2% at 2 years, and 58.6% at 3 years. Graft failure was more likely in eyes in the bump group than in those in the well-aligned group (P = 0.037, Wilcoxon test). DSAEK for failed PK had a favorable outcome in this study. However, the GHJ should be assessed carefully before performing the procedure.

  17. Endothelial keratoplasty with infant donor tissue

    PubMed Central

    Kobayashi, Akira; Yokogawa, Hideaki; Yamazaki, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa

    2014-01-01

    Here we report a case of endothelial keratoplasty with infant donor tissue obtained after brain death. A 52-year-old man with endothelial dysfunction of unknown cause in the right eye underwent non-Descemet stripping automated endothelial keratoplasty (nDSAEK) with tissue from an infant donor (2 years). Intraoperative and postoperative complications were recorded. Best corrected visual acuity and donor central endothelial cell density were recorded preoperatively and postoperatively. Infant donor tissue preparation with a microkeratome set at 300 μm was successful; the donor tissue was extremely elastic and soft compared with adult tissue. The central endothelial cell density of the infant donor tissue was as high as 4,291 cells/mm2. No complications were observed during donor tissue (8.0 mm in diameter) insertion with the double-glide technique (Busin glide with intraocular lens sheet glide) or any of the other procedures. Best corrected visual acuity improved from 1.7 logMAR (logarithm of the minimum angle of resolution; 0.02 decimal visual acuity) preoperatively to 0.2 logMAR (0.6) after 6 months and 0.1 logMAR (0.8) after 1 year. The central endothelial cell density after 6 months was 4,098 cells/mm2 (representing a 4.5% cell loss from preoperative donor cell measurements), and the central endothelial cell density after 1 year was 4,032 cells/mm2 (6.0% decrease). Infant donor tissue may be preferably used for DSAEK/nDASEK, since it may not be suitable for penetrating keratoplasty or Descemet membrane endothelial keratoplasty. PMID:25246761

  18. Outcomes of Descemet Membrane Endothelial Keratoplasty in Eyes With a Previous Descemet Stripping Automated Endothelial Keratoplasty Graft.

    PubMed

    Sorkin, Nir; Showail, Mahmood; Einan-Lifshitz, Adi; Boutin, Tanguy; Borovik, Armand; Kreimei, Mohammad; Rosenblatt, Amir; Chan, Clara C; Rootman, David S

    2018-06-01

    To analyze the outcomes of Descemet membrane endothelial keratoplasty (DMEK) in eyes with previous Descemet stripping automated endothelial keratoplasty (DSAEK). This retrospective interventional case series included 26 eyes (26 patients) that underwent DMEK to replace a previous DSAEK graft with at least 6 months of follow-up. The outcome measures were indications for surgery, best spectacle-corrected visual acuity (BSCVA), endothelial cell density, rebubbling rate, rejection, and failure. Patient age was 71.9 ± 12.6 years. The average follow-up time after DMEK was 15.1 ± 10.6 months. Indications for DMEK were DSAEK graft failure (69%) and a DSAEK suboptimal visual outcome (31%). BSCVA of the entire cohort (n = 26) improved from 1.33 ± 0.78 logMAR preoperatively to 1.04 ± 0.78 and 1.06 ± 0.89 logMAR at 6 months postoperatively and at the last follow-up, respectively (P = 0.019 and P = 0.033). BSCVA among eyes without visual comorbidities (n = 13) improved from 0.84 ± 0.50 logMAR preoperatively to 0.55 ± 0.47 and 0.51 ± 0.49 logMAR at 6 months postoperatively and at final follow-up, respectively (P = 0.023 for both). Of these eyes, 84.6% had improvement in BSCVA at 6 months postoperatively and at last follow-up. In the subgroup of 8 eyes with DMEK for suboptimal visual outcomes after DSAEK, BSCVA improved from 0.81 ± 0.44 to 0.52 ± 0.35 logMAR at final follow-up (P = 0.024). When excluding eyes with visual comorbidities, BSCVA of this subgroup (n = 5) improved from 0.54 ± 0.32 to 0.36 ± 0.25 logMAR at final follow-up (P = 0.038). BSCVA of this subgroup at 6 months postoperatively was not significantly different from preoperative BSCVA, when including visual comorbidities (n = 8, 0.75 ± 0.60 logMAR, P = 0.79) and when excluding visual comorbidities (n = 5, 0.40 ± 0.28 logMAR, P = 0.621). Endothelial cell density decreased from 2753 ± 307 cells/mm to 1659 ± 655 cells/mm 6 months after surgery (39.7% loss, P = 0.005). Three eyes (11.5%) required

  19. 5-Fluorouracil for epithelial downgrowth after Descemet stripping automated endothelial keratoplasty.

    PubMed

    Wong, Ryan K; Greene, Daniel P; Shield, David R; Eberhart, Charles G; Huang, John J; Shayegani, Aryan

    2013-12-01

    To report the use of intracameral 5-fluorouracil (5-FU) to treat epithelial downgrowth after performing a Descemet-stripping automated endothelial keratoplasty (DSAEK). We describe the case of a 79-year-old woman who underwent a DSAEK for pseudophakic Fuchs endothelial corneal dystrophy. The patient required 2 repeat DSAEKs for graft failure and persistent, visually significant interface haze. Six months after the third and most recent DSAEK, the patient was followed up and found to have a visual acuity of 20/100. On examination, the patient continued to have a persistent interface haze. However, the patient also had a cellular anterior chamber reaction despite the administration of frequent topical corticosteroids, and subtle findings of a translucent, membranous growth over the iris. Argon laser photocoagulation of the area resulted in a whitening response, characteristic of epithelial growth. Epithelial downgrowth was diagnosed, and intracameral 5-FU was administered. One month after the injection was given, the patient's examination results and vision improved to 20/60. Six months after the single injection, the patient had a clear DSAEK graft without interface haze, a quiet chamber, and 20/30 visual acuity. Epithelial downgrowth that occurs after performing a DSAEK can be treated successfully using intracameral 5-FU.

  20. DSAEK: practical approach to choose the microkeratome head on the basis of donor cornea pachymetry.

    PubMed

    Wisse, Robert P L; Achterberg, Jens A; Van der Lelij, Allegonda

    2014-03-01

    The aim of this study was to supply data on the relationship between Descemet stripping automated endothelial keratoplasty (DSAEK) graft thickness and its effects on visual acuity (VA), pace of visual recovery, endothelial cell densities (ECDs), and surgical complications. We additionally provide an approach for choosing the microkeratome blade thickness when multiple patients are scheduled for DSAEK. This is a retrospective analysis of all DSAEK procedures performed at our institute from January 2011 to December 2012. The VA was assessed at all postop visits. The ECD was assessed at 6 and 12 months postoperatively. An algorithm based on donor cornea pachymetry was used to assist in the choice of a microkeratome blade either 350 or 400 μm thick. Two groups were created on the basis of the microkeratome blade chosen. Outcomes were given per treatment group. One hundred two consecutive DSAEK procedures were performed; 60 grafts were prepared with the 350-μm blade and 39 with the 400-μm blade. Baseline characteristics did not differ materially. Grafts dissected using the 350-μm knife were significantly thicker than the grafts dissected with the 400-μm blade, with values of 257 ± 47 μm and 222 ± 33 μm, respectively (P = 0.01). The pace of visual recovery, VA at maximum follow-up, and ECD did not differ significantly between groups. Surgical complications were evenly distributed over both groups. This study indicates that using neither the 350-μm nor 400-μm microkeratome blade for the DSAEK altered the outcomes in terms of VA, ECD, and surgical complications. The algorithm presented in this study is helpful in equally distributing benefits from thinner grafting for all DSAEK-operated patients.

  1. [Descemet's stripping automated endothelial keratoplasty (DEAEK). Systematic review of clinical-effectiveness and safety].

    PubMed

    Paz-Valiñas, L; de la Fuente-Cid, R; de Rojas-Silva, M V; López-Rodríguez, I; López-García, M

    2015-04-01

    To conduct a systematic review of the efficacy/effectiveness, safety and cost of Descemet's stripping automated endothelial keratoplasty (DSAEK) technique in patients with corneal endothelial failure. Comprehensive literature search conducted in the main biomedical databases from January-May 2012. Following a critical perusal of the total of 485 abstracts retrieved, 16 case series and one economic evaluation study were included. Corrected distance visual acuity and uncorrected distance visual acuity improved after treatment with DSAEK, attaining values of 0.6 to 0.8 and 0.5 respectively. The degree of post-DSAEK astigmatism was not significant with respect to baseline values. The main complications were graft dislocation-detachment (1.5-23%), primary failure (0-12%) and endothelial rejection (0.8-8.5%). In Fuchs' dystrophy and bullous keratopathy, data on the effectiveness of DSAEK indicate post-intervention improvement in uncorrected and corrected distance visual acuity. Astigmatism arising after DSAEK was not significant. The most significant post-DSAEK complications are linked to the viability of the graft, with the most frequent complications being dislocation-detachment and, to a lesser extent, endothelial rejection. The studies that assess DSAEK are case series, and for the most part retrospective. The quality of this type of studies is both low and limited. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Candida Endophthalmitis After Descemet Stripping Automated Endothelial Keratoplasty With Grafts From Both Eyes of a Donor With Possible Systemic Candidiasis.

    PubMed

    Palioura, Sotiria; Sivaraman, Kavitha; Joag, Madhura; Sise, Adam; Batlle, Juan F; Miller, Darlene; Espana, Edgar M; Amescua, Guillermo; Yoo, Sonia H; Galor, Anat; Karp, Carol L

    2018-04-01

    To report 2 cases with late postoperative Candida albicans interface keratitis and endophthalmitis after Descemet stripping automated endothelial keratoplasty (DSAEK) with corneal grafts originating from a single donor with a history of presumed pulmonary candidiasis. Two patients underwent uncomplicated DSAEK by 2 corneal surgeons at different surgery centers but with tissue from the same donor and were referred to the Bascom Palmer Eye Institute with multifocal infiltrates at the graft-host cornea interface 6 to 8 weeks later, and anterior chamber cultures that were positive for the same genetic strain of C. albicans. Immediate explantation of DSAEK lenticules and daily intracameral and instrastromal voriconazole and amphotericin injections failed to control the infection. Thus, both patients underwent therapeutic penetrating keratoplasty with intraocular lens explantation, pars plana vitrectomy, and serial postoperative intraocular antifungal injection. Both patients are doing well at 2 years postoperatively with best-corrected vision of 20/20 and 20/30+ with rigid gas permeable lenses. One patient required repeat optical penetrating keratoplasty and glaucoma tube implantation 1 year after the original surgery. Literature review reveals that donor lenticule explantation and intraocular antifungals are often inadequate to control fungal interface keratitis, and a therapeutic graft is commonly needed. Interface fungal keratitis and endophthalmitis due to infected donor corneal tissue is difficult to treat, and both recipients of grafts originating from the same donor are at risk of developing this challenging condition.

  3. In vivo laser confocal microscopy after non-Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa

    2009-07-01

    To investigate in vivo corneal changes in patients with bullous keratopathy who underwent non-Descemet's stripping automated endothelial keratoplasty (nDSAEK) with the use of laser confocal microscopy. Single-center, prospective clinical study. Ten eyes (10 patients; 3 men and 7 women; mean age, 73.5+/-6.6 years [mean+/-standard deviation]) with bullous keratopathy were evaluated in this study. In vivo laser confocal microscopy was performed before and 1, 3, and 6 months after nDSAEK. Selected confocal images of corneal layers were evaluated qualitatively and quantitatively for degree of haze and density of deposits. Before surgery, the following were observed in all patients: corneal epithelial edema, subepithelial haze, keratocytes in a honeycomb pattern, and tiny needle-shaped materials in the stroma. After nDSAEK, subepithelial haze, donor-recipient interface haze, and interface particles were observed in all measurable cases; postoperative haze, interface particles, and needle-shaped materials decreased statistically significantly (P<0.05) over the course of follow-up. In addition, hyperreflective giant interface particles were observed after nDSAEK in all patients. In vivo laser confocal microscopy can identify subclinical corneal abnormalities after nDSAEK such as subepithelial haze, host-recipient interface haze, host stromal needle-shaped materials, and host-recipient interface particles with characteristic giant particles. Further studies with this technology in a large number of patients and long-term follow-up are needed to understand fully the long-term corneal stromal changes after nDSAEK.

  4. Slit-lamp technique of draining interface fluid following Descemet's stripping endothelial keratoplasty.

    PubMed

    Srinivasan, Sathish; Rootman, David S

    2007-09-01

    To describe a new slit-lamp technique for draining interface fluid to manage complete donor disc detachments following Descemet's stripping (automated) endothelial keratoplasty (DSEK/DSAEK). Interventional case series. Five DSEK/DSAEK patients presented on the first postoperative day with complete detachment of the donor lenticule. Slit-lamp biomicroscopy showed interface fluid preventing attachment of the donor disc to the host stromal bed. A new slit-lamp technique is described to drain the interface fluid. This technique involved completely filling the anterior chamber with an air bubble using a 30-gauge needle on a 3 ml syringe. Following this, a 0.12 forceps was used to open the inferior mid-peripheral corneal drainage slit to drain the interface fluid. This technique was successful in draining the interface fluid in all five patients, leading to immediate complete reattachment of the donor disc. Donor disc detachments following DSEK/DSAEK can be successfully managed by this slit-lamp technique of draining the interface fluid.

  5. No-Touch Technique and a New Donor Adjuster for Descemet's Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa

    2012-01-01

    Purpose One difficulty with Descemet's stripping automated endothelial keratoplasty (DSAEK) is air management during surgery and donor endothelial lamella centering. We evaluated the no-touch technique for donor centering and the use of a newly developed DSAEK donor adjuster. Methods We evaluated the records of 12 consecutive patients (mean age 75.3 years) with bullous keratopathy who had undergone DSAEK. In all cases, the no-touch technique was attempted first. When the no-touch technique failed, a DSAEK donor adjuster with a 30-gauge cannula resembling a curved reverse Sinskey hook was used for donor centering. The adjuster allows air injection during donor centering. Results The no-touch technique using simple corneal surface massage to center the graft was successful in 4 cases (33.3%), while 4 cases required ocular tilting (33.3%) in addition to corneal surface massage. The no-touch technique was ineffective in 4 cases (33.3%), but the donor adjuster was used successfully and easily for these patients. Comparing the endothelial cell loss rate between the no-touch technique group and the donor adjuster group, there was no significant difference at 6 months. Conclusions The no-touch technique was useful for better control of DSAEK donor centering in most cases. When the no-touch technique was ineffective, the DSAEK donor adjuster was uniformly successful. PMID:22807910

  6. Single-Pass Microkeratome System for Eye Bank DSAEK Tissue Preparation: Is Stromal Bed Thickness Predictable and Reproducible?

    PubMed

    Choulakian, Mazen Y; Li, Jennifer Y; Ramos, Samuel; Mannis, Mark J

    2016-01-01

    To evaluate the predictability and reproducibility of stromal bed thickness for single-pass donor Descemet stripping automated endothelial keratoplasty (DSAEK) tissue preparation, using the ML7 Microkeratome Donor Cornea System (Med-logics Inc, Athens, TX). In this retrospective chart review of 256 consecutive corneal tissue preparations for DSAEK surgery, from June 2013 to August 2014, tissue thicknesses were divided into 3 groups, depending on surgeon preference: <91 μm (group A), 90 to 120 μm (group B), and 120 to 160 μm (group C). Precut and postcut data were recorded. Average postcut donor corneal thickness was 114 ± 30 μm (range 60-183 μm), whereas the average in group A was 97 ± 23 μm (range 60-128), in group B was 113 ± 21 μm (range 77-179), and in group C was 134 ± 43 (range 89-183). Average postcut endothelial cell density was very adequate at 3013 ± 250 cells per square millimeter. There were a total of 7 failed procedures from 256 attempts, which represents a rate of 2.7%. This rate decreases to 1.5% when analyzing the last 200 cuts. The ML7 Microkeratome Donor Cornea System allows for reliable and reproducible DSAEK tissue preparation. Ultrathin DSAEK tissues can be prepared with a single-pass. Aiming for a graft thickness between 90 and 120 μm seems to be most reliable.

  7. Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Tomida, Daisuke; Yamaguchi, Takefumi; Ogawa, Akiko; Hirayama, Yumiko; Shimazaki-Den, Seika; Satake, Yoshiyuki; Shimazaki, Jun

    2015-07-01

    To compare short-term outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) using a graft prepared with either a femtosecond laser or a microkeratome. Thirty-eight patients underwent DSAEK with grafts prepared with either a femtosecond laser (f-DSAEK; 21 eyes) or a microkeratome (m-DSAEK; 17 eyes). Visual acuity, endothelial cell density, regular astigmatism and irregular astigmatism were compared between the two groups preoperatively and at 1, 3, and 6 months post-operatively. Fourier analysis was conducted to calculate astigmatism of the anterior and posterior surfaces, and total cornea, using anterior segment optical coherence tomography (AS-OCT). Visual acuity (logMAR) improved from 1.20 ± 0.60 to 0.43 ± 0.25 after m-DSAEK (P < 0.001) and from 1.20 ± 0.57 to 0.77 ± 0.33 after f-DSAEK (P = 0.0028) at 6 months following DSAEK. Visual acuity after m-DSAEK was significantly better than after f-DSAEK at 1, 3, and 6 months (P < 0.05). AS-OCT corneal images revealed greater irregularities on the posterior surfaces of f-DSAEK grafts compared to m-DSAEK grafts. Irregular astigmatism of the total cornea and the posterior surface was significantly larger after f-DSAEK than after m-DSAEK, although there was no significant difference in irregular astigmatism of the anterior surface at 6 months. Postoperative visual acuity was significantly correlated with the postoperative irregular astigmatism of the total cornea (r = 0.6657 and P < 0.001) and the anterior (r = 0.416, P = 0.016) and posterior surfaces (r = 0.7046, P < 0.001). Visual outcomes after f-DSAEK were poor compared to conventional m-DSAEK due to an increase in irregular astigmatism caused by posterior surface irregularities.

  8. Topographic hot spot before descemet stripping automated endothelial keratoplasty is associated with postoperative hyperopic shift.

    PubMed

    Shimizu, Tsutomu; Yamaguchi, Takefumi; Satake, Yoshiyuki; Shimazaki, Jun

    2015-03-01

    The aim of this study was to investigate topographic "hot spots" on the anterior corneal surface before Descemet stripping automated endothelial keratoplasty (DSAEK) and their effects on postoperative visual acuity and hyperopic shift. Twenty-seven eyes of 27 patients with bullous keratopathy, who underwent DSAEK were studied. We defined a hot spot as a focal area with relatively high refractive power on the anterior corneal surface in eyes with bullous keratopathy. Refractive spherical equivalent, keratometric value, and corneal topography were retrospectively evaluated using anterior segment optical coherence tomography (AS-OCT). Hot spots were identified in 11 eyes (42.3%) before DSAEK and disappeared in 9 eyes of these eyes (81.8%) at 6 months after DSAEK. AS-OCT revealed focal epithelial thickening in the same areas as the hot spots. There was no significant difference in the postoperative visual acuity between eyes with and without hot spots (P > 0.05). The keratometric value of the anterior corneal surface significantly flattened from 45.7 ± 2.7 diopters (D) before DSAEK to 44.2 ± 2.7 D 1 month after DSAEK in eyes with hot spots (P = 0.01), whereas in eyes without hot spots, there were no significant differences in the keratometric values before and after DSAEK. At 6 months, the refractive change was +1.1 ± 1.3 D in eyes with hot spots and -0.2 ± 0.6 D in eyes without hot spots (P = 0.034). In eyes with focal epithelial thickening, topographic hot spots on the anterior corneal surface were observed using AS-OCT. The hot spots disappeared after DSAEK and had no influence on the postoperative visual acuity.

  9. Assessment of eye bank-prepared posterior lamellar corneal tissue for endothelial keratoplasty.

    PubMed

    Rose, Linda; Briceño, César A; Stark, Walter J; Gloria, Dante G; Jun, Albert S

    2008-02-01

    To evaluate eye bank-prepared tissue for Descemet's stripping automated endothelial keratoplasty (DSAEK). Experimental study and retrospective case series. Seventeen human donor corneas and 4 recipient patients undergoing DSAEK surgery. Corneal-scleral discs were obtained. Specular microscopy and pachymetry were performed. A designated Tissue Banks International technician used a microkeratome to prepare a flap. Posterior bed thickness was measured. The sectioned tissue was stored, and at 24 and 48 hours, pachymetry was repeated. At 48 hours, specular microscopy was repeated, and endothelial cell viability was assessed with trypan blue. Descemet's stripping automated endothelial keratoplasty was performed in 4 patients using eye bank-prepared posterior lamellar tissue. Corneal tissue was assessed with the following parameters: corneal thickness measured with ultrasonic pachymetry, cell density counts measured with a keratoanalyzer, and cell viability as observed with trypan blue exclusion. Patient outcomes were measured by changes in visual acuity (VA) and the presence of a clear graft. Donor corneal pachymetry before sectioning averaged 599+/-52 microm. Immediately after sectioning with a microkeratome set at a depth of 300 microm, mean posterior bed thickness was 328+/-95 microm. Thus, the mean cutting depth achieved by the microkeratome when set at 300 micrometers averaged 271+/-83 microm. After storage for 24 hours, the posterior beds measured 352 microm, an average swelling of 24 (7%) microm (P = 0.14). After 48 hours, the posterior beds measured 382 microm, an average swelling of 54 (16%) microm (P = 0.02). Cell counts 48 hours after sectioning decreased by an average of 11% (P = 0.10). Endothelial cell staining confirmed improvement in postsectioning morphology and survival with increased technician experience. All 4 patients receiving eye bank-prepared DSAEK tissue showed uncomplicated postoperative results, with improvement in VA. The microkeratome cutting

  10. The use of postoperative slit-lamp optical coherence tomography to predict primary failure in descemet stripping automated endothelial keratoplasty.

    PubMed

    Shih, Carolyn Y; Ritterband, David C; Palmiero, Pat-Michael; Seedor, John A; Papachristou, George; Harizman, Noga; Liebmann, Jeffrey M; Ritch, Robert

    2009-05-01

    To determine if central donor lenticle thickness as measured by slit-lamp optical coherence tomography (SL OCT; Heidelberg Engineering, Heidelberg, Germany) is predictive of primary donor failure in patients undergoing Descemet stripping automated endothelial keratoplasty (DSAEK). Retrospective cross-sectional study. Eighty-four patients who underwent DSAEK surgery by 2 surgeons (D.C.R. and J.A.S.) were enrolled. At each postoperative visit (postoperative day 1, week 1, month 1, and month 2), an SL OCT scan was obtained. Statistical differences in SL OCT measurements of successful and failed DSAEK procedures were measured using the Student t test. A successful DSAEK surgery was defined as having an anatomically attached, clear recipient corneal stroma and donor lenticle compatible with good vision 2 months after surgery. A failed DSAEK surgery was defined as an attached donor lenticle with SL evidence of corneal edema and thickening visible at 2 months or more. Ninety-three eyes of 84 consecutive patients who underwent DSAEK surgery also underwent postoperative SL OCT. After 2 months of follow-up, 82 (88%) procedures were successful and 11 (12%) procedures were failures. The average donor lenticle thickness in successful DSAEK eyes was 314 +/- 128 microm on postoperative day 1 as compared with failed DSAEK eyes, which averaged 532 +/- 259 microm (P = .0013). This was independent regardless of whether the lenticle was attached on the first postoperative visit. Seventy-nine (98%) successful DSAEK eyes had a lenticle thickness of < or = 350 microm at the 1-week visit. All of the failed DSAEK eyes (11 eyes) had a lenticle thickness > or = 350 microm at the 1-week postoperative visit. Statistically significant differences in SL OCT thickness measurements were seen between successful and failed DSAEK cases at all examinations after postoperative week 1. Corneal thickness measurements made with SL OCT are an important predictor of DSAEK failure in both attached and

  11. Post DSAEK Optical Changes: A Comprehensive Prospective Analysis on the Role of Ocular Wavefront Aberrations, Haze, and Corneal Thickness

    PubMed Central

    Hindman, Holly B.; Huxlin, Krystel R.; Pantanelli, Seth M.; Callan, Christine L.; Sabesan, Ramkumar; Ching, Steven S.T.; Miller, Brooke E.; Martin, Tim; Yoon, Geunyoung

    2014-01-01

    Purpose To assess the visual impact of ocular wavefront aberrations, corneal thickness, and corneal light scatter prospectively after Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK) in humans. Methods Data were obtained prospectively from 20 eyes pre-operatively and at 1, 3, 6, and 12 months post- DSAEK. At each visit, best spectacle corrected visual acuity (BSCVA) and visual acuity with glare (Brightness Acuity Testing - BAT) were recorded and ocular wavefront measurements and corneal Optical Coherence Tomography (OCT) performed. Magnitude and sign of individual Zernike terms (higher order aberrations HOA) were determined. Epithelial, host stromal, donor stromal, and total corneal thickness were quantified. Brightness, intensity profiles of OCT images were generated to quantify light scatter in the whole cornea, subepithelial region, anterior and posterior host stroma, interface, and donor stroma. Results Mean BSCVA and glare disability at low light levels improved from 1 to 12 months post-DSAEK. All corneal thicknesses and ocular lower- and HOAs were stable from 1 through 12 months, whereas total corneal, host stromal, and interface brightness intensities decreased significantly over the same period. A repeated measures ANOVA across the follow up period found that the change in scatter, but not the change in higher order aberrations, could account for the variability occurring in acuity from 1 to 12 months post-DSAEK. Conclusions While ocular HOAs and scatter are both elevated over normal post-DSAEK, our results demonstrate that improvements in visual performance occurring over the first year post-DSAEK are associated with decreasing light scatter. In contrast, there were no significant changes in ocular HOAs during this time. Because corneal light scatter decreased between 1 and 12 months despite stable corneal thicknesses over the same period, we conclude that factors that induced light scatter, other than tissue thickness or swelling (corneal

  12. Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty

    PubMed Central

    Salvetat, M L; Zeppieri, M; Miani, F; Tosoni, C; Parisi, L; Brusini, P

    2011-01-01

    Purpose To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP. Methods This prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automated-endothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland–Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP. Results iCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, P<0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of −6.5±1.9 mm Hg, P<0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes. Conclusions The agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP. PMID:21436848

  13. Preparation of pre-cut corneas from fresh donated whole globes for Descemet's stripping automated keratoplasty: 3-year results at the Central Eye Bank of Iran.

    PubMed

    Kanavi, Mozhgan Rezaei; Javadi, Mohammad Ali; Javadi, Fatemeh; Chamani, Tahereh

    2014-09-01

    To describe the technique and the results of the preparation of pre-cut corneas for Descemet's stripping automated endothelial keratoplasty (DSAEK) during a 3-year period at the Central Eye Bank of Iran (CEBI). The method of preparation of pre-cut corneas from donated whole globes at the CEBI is described and the frequency and percentage of pre-cut corneas prepared for DSAEK, between April 2009 and March 2012, are specified. Moreover, post-operative reports are reviewed for any complaints about using pre-cut tissues for DSAEK. Out of the 1,518 donated whole globes appropriate for DSAEK, 1,478 (97.4 %) pre-cut corneas were successfully prepared. The method of preparation failed in 40 (2.6 %) cases. Based on the eye bank post-operative reports, thickness of pre-cut tissues for DSAEK was deemed unacceptable in only 6 (0.4 %) cases prior to surgery; five of these were too thick and one was too thin. Preparation of pre-cut corneas, for DSAEK from donated whole globes, in the CEBI is a safe and easy method, with very good preservation of endothelial cells after the preparation of the pre-cut corneas and reduced risks from corneal manipulation.

  14. Outcome of Descemet stripping automated endothelial keratoplasty in eyes with an Ahmed glaucoma valve.

    PubMed

    Chiam, Patrick J; Cheeseman, Robert; Ho, Vivian W; Romano, Vito; Choudhary, Anshoo; Batterbury, Mark; Kaye, Stephen B; Willoughby, Colin E

    2017-05-01

    The purpose was to investigate the survival of Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with an Ahmed glaucoma valve (AGV). The study had a retrospective case-series of patients with an AGV in the anterior chamber undergoing a DSAEK. Included in the analysis were graft size, number of previous operations, post-operative glaucoma medications, post-operative intraocular pressure (IOP) control, graft size and donor factors (age, endothelial cell density, and post-mortem time). A generalised linear model with binary logistic regression was used to test for an effect on graft survival at 1 year and 1.5 years. Fourteen eyes from 13 patients were included. The survival rate of the first DSAEK at 6, 12, 18, 24 and 30-months was 85%, 71%, 50%, 36% and 30%, respectively. The mean duration to graft failure was 12.9 ± 6.2 months. Five of the seven failed first grafts went on to have a repeat DSAEK. The mean follow-up in this subgroup was 30.7 ± 18.4 months. The survival rate of second DSAEK at 6, 12, 18 and 24 months was 100% (5/5), 100% (5/5), 75% (3/4) and 67% (2/3). Only one second DSAEK failed in the duration of the study and went on to receive a third DSAEK which failed at 18-months. The mean IOP within the first year was significantly lower for grafts that survived at 1 and 1.5 years (17.4 mmHg, 16.9 mmHg) than for grafts that failed (19.4 mmHg, 19.4 mmHg) (p = 0.04, p = 0.009). DSAEK is a viable alternative to PK to restore visual function in eyes with an AGV sited in the anterior chamber. IOP is an important risk factor for graft failure.

  15. Eye bank survey of surgeons using precut donor tissue for descemet stripping automated endothelial keratoplasty.

    PubMed

    Kitzmann, Anna S; Goins, Kenneth M; Reed, Cynthia; Padnick-Silver, Lissa; Macsai, Marian S; Sutphin, John E

    2008-07-01

    To assess surgeon satisfaction with precut corneal tissue from 1 eye bank for Descemet stripping automated endothelial keratoplasty (DSAEK). Surgical techniques and predictors of procedural success were also examined. A 19-question survey was completed by 53 surgeons around the United States for 197 DSAEK cases using prepared corneal allograft tissue from the Iowa Lions Eye Bank. Surgeries were performed between April 1 and December 31, 2006; surveys were completed retrospectively within a few weeks of surgery. Tissue was found to be acceptable in 98% of DSAEK cases reported. Difficulties with precut tissue (eg, lack of anterior cap adherence to the posterior lamella, not visible or decentered central dot, anterior edge undermining) were reported in approximately 10% of cases. A rebubbling procedure was performed in 23% of cases for donor dislocations. The donor lenticule adhered, with resulting corneal deturgescence, in 86% of cases. Surgeons declared a successful procedure in 92% of cases. Of the 14 unsuccessful cases, donor tissue quality was the underlying etiology in only 1 case. Procedural success rates were related to surgeon experience (P = 0.002), lenticule adherence after only 1 anterior chamber air bubble (P = 0.005), no small perforations to release fluid (P = 0.005), and the presence of corneal deturgescence (P = 0.002). The use of precut tissue for DSAEK is not associated with increased risk of complications related to tissue preparation. With standardization of precutting donor tissue, safety of DSAEK surgery may be improved while increasing surgeon efficiency.

  16. Effect of incision width on graft survival and endothelial cell loss after DSAEK

    PubMed Central

    Price, Marianne O.; Bidros, Maria; Gorovoy, Mark; Price, Francis W.; Benetz, Beth A.; Menegay, Harry J.; Debanne, Sara M.; Lass, Jonathan H.

    2009-01-01

    Purpose To assess the effect of incision width (5.0 and 3.2 mm) on graft survival and endothelial cell loss six months and one year after Descemet stripping automated endothelial keratoplasty (DSAEK). Methods One hundred sixty-seven subjects with endothelial decompensation from a moderate-risk condition (principally Fuchs’ dystrophy or pseudophakic corneal edema) underwent DSAEK by two experienced surgeons. The donor was folded over and inserted with single point fixation forceps. This retrospective analysis assessed graft survival, complications, and endothelial cell loss, which was calculated from baseline donor and 6-month and 1-year postoperative central endothelial images evaluated by an independent specular microscopy reading center. Results No primary graft failures occurred in either group. One-year graft survival rates were comparable (98% vs. 97%) in the 5.0- and 3.2-mm groups, respectively (P=1.0). Complications included graft dislocation, graft rejection episodes, and elevated intraocular pressure and occurred at similar rates in both groups (P ≥ 0.28). Pupillary block glaucoma did not occur in either group. Mean baseline donor endothelial cell density did not differ: 2782 cells/mm2 in the 5.0-mm (n=64) and 2784 cells/mm2 in the 3.2-mm (n=103) groups. Percent endothelial cell loss was 27±20% (n=55) vs. 40±22% (n=71; 6 months) and 31±19% (n=45) vs. 44±22% (n=62; 12 months) in the 5.0-mm and 3.2-mm incision groups, respectively (both P<0.001). Conclusions One year after DSAEK, overall graft success was comparable for the two groups; however, the 5.0-mm incision width resulted in substantially lower endothelial cell loss at 6 and 12 months. PMID:20299973

  17. Keratocyte Apoptosis and Not Myofibroblast Differentiation Mark the Graft/Host Interface at Early Time-Points Post-DSAEK in a Cat Model

    PubMed Central

    Weis, Adam J.; Huxlin, Krystel R.; Callan, Christine L.; DeMagistris, Margaret A.; Hindman, Holly B.

    2013-01-01

    Purpose To evaluate myofibroblast differentiation as an etiology of haze at the graft-host interface in a cat model of Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK). Methods DSAEK was performed on 10 eyes of 5 adult domestic short-hair cats. In vivo corneal imaging with slit lamp, confocal, and optical coherence tomography (OCT) were performed twice weekly. Cats were sacrificed and corneas harvested 4 hours, and 2, 4, 6, and 9 days post-DSAEK. Corneal sections were stained with the TUNEL method and immunohistochemistry was performed for α-smooth muscle actin (α-SMA) and fibronectin with DAPI counterstain. Results At all in vivo imaging time-points, corneal OCT revealed an increase in backscatter of light and confocal imaging revealed an acellular zone at the graft-host interface. At all post-mortem time-points, immunohistochemistry revealed a complete absence of α-SMA staining at the graft-host interface. At 4 hours, extracellular fibronectin staining was identified along the graft-host interface and both fibronectin and TUNEL assay were positive within adjacent cells extending into the host stroma. By day 2, fibronectin and TUNEL staining diminished and a distinct acellular zone was present in the region of previously TUNEL-positive cells. Conclusions OCT imaging consistently showed increased reflectivity at the graft-host interface in cat corneas in the days post-DSAEK. This was not associated with myofibroblast differentiation at the graft-host interface, but rather with apoptosis and the development of a subsequent acellular zone. The roles of extracellular matrix changes and keratocyte cell death and repopulation should be investigated further as potential contributors to the interface optical changes. PMID:24098706

  18. Express implant in Urrets-Zavalia syndrome after descemet's stripping automated endothelial keratoplasty.

    PubMed

    Muñoz-Morales, A; del Trigo-Zamora, J R; Sánchez-Vicente, J L; Lozano-Bernal, O; Luchena-López, R

    2015-10-01

    The first case is described on a patient with Urrets-Zavalía syndrome after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in whom an ExPRESS implant was used. The ExPRESS implant is a useful tool for complex cases of post-surgical glaucoma where patients need to avoid post-operative inflammation and risks (corneal transplant patients). It is also very useful in cases with a high risk of fibrosis due to previous interventions. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Descemet’s stripping and non-Descemet’s stripping automated endothelial keratoplasty for microcornea using 6.0 mm donor grafts

    PubMed Central

    Yokogawa, Hideaki; Kobayashi, Akira; Yamazaki, Natsuko; Ueta, Yoshiki; Hashimoto, Yoshihiro; Tachi, Naoko; Sugiyama, Kazuhisa

    2013-01-01

    Background The purpose of this paper is to report our experience of Descemet’s stripping and non-Descemet’s stripping automated endothelial keratoplasty (DSAEK/nDSAEK) for microcorneas using 6.0 mm donor grafts. Methods Three eyes of two patients (a 56-year-old woman and a 59-year-old woman) with microcornea and suffering from bullous keratopathy were treated with either DSAEK or nDSAEK. A small donor graft (6.0 mm) was inserted into the anterior chamber using a double glide (Busin glide and intraocular lens sheet glide) donor insertion technique. Both patients were followed for at least 12 months. Clinical outcomes, including intraoperative and postoperative complications, visual acuity, and endothelial cell density were evaluated. Results In all three cases (100%), no intraoperative complications were noted. In one case with a flat keratometry value (32.13 D), a partial donor detachment was noted one day postoperatively, but it was reattached by rebubbling. In another case, rejection was noted 8 months postoperatively, but treatment with systemic corticosteroids was successful. A clear cornea remained in all three cases (100%), with best-corrected visual acuity greater than 20/100 (mean 20/50) at 12 months. Mean postoperative endothelial cell counts were 2,603 ± 18 cells/mm2 at 6 months (7.4% decrease from preoperative donor cell counts) and 1,799 ± 556 cells/mm2 at 12 months (36.5% decrease). Conclusion We report for the first time the successful use of a small donor graft (6.0 mm) for DSAEK/nDSAEK in cases of microcornea. Additional stud ies using a large number of patients are required to evaluate fully the potential advantages and drawbacks of small diameter donor grafts for microcornea. PMID:24109176

  20. Viscoelastic-Assisted Non-Descemet Stripping Automated Endothelial Keratoplasty in Vitrectomized and Iris-Lens Diaphragm Injured Eyes.

    PubMed

    Ren, Yueping; Zhao, Zelin; Shao, Yumei; Waller, Stephen G; Jhanji, Vishal; Chen, Wei

    2015-11-01

    To report the outcomes of viscoelastic-aided non-Descemet stripping automated endothelial keratoplasty (nDSAEK) to treat bullous keratopathy in vitrectomized and iris-lens diaphragm injured eyes. A prospective consecutive case series of eyes with bullous keratopathy underwent nDSAEK. About 0.15 to 0.2 mL cohesive viscoelastic was injected into the anterior chamber in front of the iris defect to prevent air from entering the posterior chamber and vitreous cavity. Filtered air was injected until the intraocular pressure (IOP) rose to a mildly high level. Graft position and complications were monitored postoperatively. Endothelial cell density and best-corrected visual acuity (BCVA) were recorded at a 1-year follow-up. Viscoelastic-aided nDSAEK was performed in 21 cases (11 males, 10 females; mean age: 58.9±12.4 years). No intraoperative complications were noted. Effective graft adherence was achieved in all cases intraoperatively. Postoperatively, partial graft dislocation was seen in 2 cases because of hypotony (IOP, 6 and 5 mm Hg, respectively) due to postoperative cyclodialysis as demonstrated on anterior segment optical coherence tomography. Hypotony was successfully managed conservatively with spontaneous graft reattachment. One year postoperatively, the median BCVA improved to 20/50. The mean endothelial cell loss was 14.7±12.6% and 20.5±11.1% at 6 months and 1 year, respectively. In vitrectomized and iris-lens diaphragm injured eyes, viscoelastic-aided nDSAEK effectively facilitated graft adherence and reduced graft dislocation. Appropriate control of IOP was considered to play a vital role in supporting the graft adherence.

  1. Nomogram to Predict Graft Thickness in Descemet Stripping Automated Endothelial Keratoplasty: An Eye Bank Study.

    PubMed

    Bae, Steven S; Menninga, Isaac; Hoshino, Richard; Humphreys, Christine; Chan, Clara C

    2018-06-01

    The purpose of this study was to develop a nomogram to predict postcut thickness of corneal grafts prepared at an eye bank for Descemet stripping automated endothelial keratoplasty (DSAEK). Retrospective chart review was performed of DSAEK graft preparations by 3 experienced technicians from April 2012 to May 2017 at the Eye Bank of Canada-Ontario Division. Variables collected included the following: donor demographics, death-to-preservation time, death-to-processing time, precut tissue thickness, postcut tissue thickness, microkeratome head size, endothelial cell count, cut technician, and rate of perforation. Linear regression models were generated for each microkeratome head size (300 and 350 μm). A total of 780 grafts were processed during the study period. Twelve preparation attempts resulted in perforation (1.5%) and were excluded. Mean precut tissue thickness was 510 ± 49 μm (range: 363-670 μm). Mean postcut tissue thickness was 114 ± 22 μm (range: 57-193 μm). Seventy-nine percent (608/768) of grafts were ≤130 μm. The linear regression models included precut thickness and donor age, which were able to predict the thickness to within 25 μm 80% of the time. We report a nomogram to predict thickness of DSAEK corneal grafts prepared in an eye bank setting, which was accurate to within 25 μm 80% of the time. Other eye banks could consider performing similar analyses.

  2. Descemet Stripping Automated Endothelial Keratoplasty for Endothelial Dysfunction in Xeroderma Pigmentosum: A Clinicopathological Correlation and Review of Literature.

    PubMed

    Vira, Divya; Fernandes, Merle; Mittal, Ruchi

    2016-07-01

    Xeroderma pigmentosum (XP) mainly affects the ocular surface; however, endothelial damage may also occur. We would like to report changes in the endothelial-Descemet layer and review the literature on similar findings in patients with XP, including the role of Descemet stripping automated endothelial keratoplasty (DSAEK) in the management of a 21-year-old man who presented with nonresolving corneal edema in the right eye after excision biopsy for conjunctival intraepithelial neoplasia. His best-corrected visual acuity (BCVA) was 20/200 in the right eye and 20/20 in the left eye. On general examination, there was patchy hyperpigmentation of the exposed areas of skin suggestive of XP. On examination of the right eye, there was stromal edema involving the exposed half of cornea. The left eye appeared normal. Pachymetry readings were 860 and 600 μm in the right and left eye, respectively. Descemet stripping automated endothelial keratoplasty was performed for endothelial dysfunction and the stripped endothelium, and Descemet membrane (DM) was sent for histopathologic evaluation. Postoperatively, the donor lenticule was well apposed and the overlying stromal edema resolved. The patient achieved a BCVA of 20/30 in the right eye without progression of corneal scarring at 1-year follow-up. In the meanwhile, however, the left eye developed corneal edema. Histopathology revealed gross attenuation of endothelial cells with uniform thickness of the DM. Corneal endothelial dysfunction in XP is amenable to treatment with DSAEK.

  3. Outcomes of descemet stripping automated endothelial keratoplasty using imported donor corneas.

    PubMed

    Lekhanont, Kaevalin; Vanikieti, Kavin; Nimvorapun, Nutthida; Chuckpaiwong, Varintorn

    2017-04-05

    The lack of development of local donor tissue acquisition in several regions of the world has resulted in the necessity of performing keratoplasty with imported donor corneas. The greatest concern about the use of donor corneas supplied by foreign eye banks is the effect of the increased donor death-to-operation time which inevitably occurs during the tissue recovery, tissue processing, and tissue transfer between the countries. The purpose of this study was to report the outcomes of descemet stripping automated endothelial keratoplasty (DSAEK) using imported donor corneas. This retrospective, non-comparative case series investigated the outcomes of the 102 consecutive DSAEK procedures using imported donor corneas performed at a single university-based hospital between August 2006-2014. The main outcome measures were postoperative best-corrected visual acuity (BCVA), endothelial cell density (ECD), and complications. The mean death-to-operation time was 9.52 ± 1.48 days (range, 8-13). The mean preoperative ECD was 2761 ± 285 cells/mm 2 . Fuchs' endothelial dystrophy was the predominant indication for grafting. The mean follow-up duration was 65.3 months. Ninety-three eyes had improved vision postoperatively (91.18%). BCVA unchanged in 3 eyes due to preexisting macular scar and advanced glaucoma. Primary graft failure occurred in 6 eyes (5.88%). Of the 93 eyes with improved BCVA, 100% had their best corrected vision within the first 1 year. The mean ECD at 6, 12, 24, 36, and 60 months after surgery was 1762 ± 294 cells/mm 2 , 1681 ± 284 cells/mm 2 , 1579 ± 209 cells/mm 2 , 1389 ± 273 cells/mm 2 , and 1251 ± 264 cells/mm 2 respectively. The mean ECD loss at 6 months, 1 year, 2 years, 3 years, and 5 years after surgery was 36.2%, 39.1%, 42.8%, 49.7%, and 54.7% respectively. The most common complication was graft detachment/dislocation (10.78%). There were no cases of any postoperative infection. DSAEK with imported donor corneas provides

  4. Tissue quality of eye-bank-prepared precut corneas for Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Nelson, Brian A; Ritenour, Rusty J

    2014-02-01

    To evaluate endothelial cell density (ECD) of eye-bank-prepared tissue for use in Descemet's stripping automated endothelial keratoplasty (DSAEK). Prospective case series of consecutive corneal tissue prepared for DSAEK surgery. Sixty-seven sequential corneal-scleral tissue specimens representing 48 human donors processed for use in DSAEK surgery by the Regional Tissue Bank (Halifax, Nova Scotia). Corneal-scleral donor tissue was obtained by in situ recovery. ECD was recorded using the EB-3000 XYZ (HAI Laboratories Inc, Lexington, MA) specular microscope within 24 hours of preservation. Before the tissue was dissected, the corneal thickness was measured using the DGH-550 PACHETTE 2 (DGH Technology, Exton, PA) ultrasound pachymeter. The dissection was performed using a 300-μm Moria ALTK model microkeratome (Moria Inc). The posterior bed thickness was measured, and the anterior flap was replaced. Endothelial cell count density was obtained after re-preservation. Complete measurements were obtained for 42 of 67 corneas. In 25 corneas it was not possible to obtain a postdissection ECD measurement. The mean ECD before dissection was 2806 ± 317 cells/mm(2). The mean ECD after dissection was 2772 ± 318 cells/mm(2). There was an average loss of 34 cells/mm(2) (95% CI -110 to 40 cells/mm(2), p = 0.3). This case series confirms that ECD is preserved when DSAEK tissue is prepared in advance of surgery by trained eye-bank technicians in a low-volume Canadian eye bank. It was difficult to obtain clear images of the endothelial cell layer postdissection, possibly because of tissue swelling or distortion. Sixty-six of 67 corneas included in the study were used for surgery. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.

  5. Combined use of a femtosecond laser and a microkeratome in obtaining thin grafts for Descemet stripping automated endothelial keratoplasty: an eye bank study.

    PubMed

    Murta, Joaquim N; Rosa, Andreia M; Quadrado, Maria Joao C; Russo, Ana D; Brito, Sergio S; Silva, Maria Fátima L

    2013-01-01

    To evaluate the use of a femtosecond laser combined with a microkeratome in the preparation of posterior corneal disks for Descemet stripping automated endothelial keratoplasty (DSAEK). This experimental study involved ultrathin DSAEK tissue preparation of 22 donor corneas unsuitable for transplantation. The first cut was performed with an Intralase® FS60 laser and the second cut with a Moria CBm 300-µm microkeratome. The thickness of the first cut was modified for each cornea to obtain a final graft thickness of less than 110 µm. Precut and postcut central pachymetry were performed with an ultrasonic pachymeter. Central endothelial cell density (ECD) was calculated before and 24 hours after tissue preparation. Final graft thickness was 105.0 ± 26.1 (SD) µm (range 65-117). The mean microkeratome head cut thickness was 324.5 ± 10.9 µm (range 310-345). Precut and postcut ECDs averaged 2250 ± 222 and 2093 ± 286 cells/mm2, respectively, representing 6.9% of cell loss. No corneas were perforated. Femtosecond FS60 lasers and Moria CBm 300-µm microkeratomes can be used sequentially to prepare consistently thin DSAEK grafts with no irregular cuts or cornea perforations.

  6. Development of Selective Lamellar Keratoplasty within an Asian Corneal Transplant Program: The Singapore Corneal Transplant Study (An American Ophthalmological Society Thesis)

    PubMed Central

    Tan, Donald; Ang, Marcus; Arundhati, Anshu; Khor, Wei-Boon

    2015-01-01

    Purpose: To evaluate outcomes of anterior lamellar keratoplasty (ALK) and endothelial keratoplasty (EK) within the Singapore Corneal Transplant Study (SCTS), with the hypothesis that both ALK and EK are able to provide equivalent or improved clinical outcomes, compared to penetrating keratoplasty (PK), and to determine changing trends globally with other international databases. Methods: Clinical data on all transplants performed was derived from our SCTS database, a prospective national keratoplasty registry, and clinical outcomes (graft survival, endothelial cell loss, complications, visual acuity) were compared between PK, ALK, and EK. Global trends on indications and forms of keratoplasty performed in 2011/2012 were obtained from national keratoplasty or eye banking registries, corneal/ophthalmological societies, national eye banks, and national ophthalmic institutions. Results: Global rates of EK surgery vary widely, from 52% (Sweden) to 0% (South Africa), with higher adoption by industrialized countries. ALK adoption rates similarly vary from 28.7% (China) to 1.0% (Philippines). SCTS data show high adoption rates in Singapore: EK 44% and ALK 28%. Our surgical modifications to big-bubble deep anterior lamellar keratoplasty (DALK) surgery resulted in visual outcomes matching PK, and a low conversion to PK of 2.1%, whereas our evolving approaches to donor insertion in Descemet’s stripping automated endothelial keratoplasty (DSAEK) show significant reduction in 1-year postoperative endothelial cell loss rates from 60% (folding), to 22% to 30% (Sheets Glide), to 15% (EndoGlide inserter). Conclusion: Improvements in various forms of ALK and EK surgery can lead to better visual outcomes, longer graft survival, and reduced complications, as compared to PK. Global trends suggest adoption of these procedures at different rates. PMID:26755854

  7. Patients with Fuchs Endothelial Dystrophy and Cataract Undergoing Descemet Stripping Automated Endothelial Keratoplasty and Phacoemulsification with Intraocular Lens Implant: Staged versus Combined Procedure Outcomes.

    PubMed

    Sykakis, Evripidis; Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian

    2015-01-01

    Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods.

  8. Patients with Fuchs Endothelial Dystrophy and Cataract Undergoing Descemet Stripping Automated Endothelial Keratoplasty and Phacoemulsification with Intraocular Lens Implant: Staged versus Combined Procedure Outcomes

    PubMed Central

    Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian

    2015-01-01

    Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods. PMID:26064669

  9. Twenty-nine-gauge dual-chandelier retroillumination for the non-open-sky continuous curvilinear capsulorhexis in the penetrating keratoplasty triple procedure.

    PubMed

    Yokokura, Shunji; Hariya, Takehiro; Kobayashi, Wataru; Meguro, Yasuhiko; Nishida, Kohji; Nakazawa, Toru

    2017-03-01

    We describe a technique for the penetrating keratoplasty (PKP) triple procedure that uses 29-gauge dual-chandelier illumination during creation of a non-open-sky continuous curvilinear capsulorhexis (CCC). The chandeliers are inserted through the pars plana into the vitreous cavity through the bulbar conjunctiva at the 3 o'clock and 9 o'clock positions. We compared this approach with that of a core vitrectomy, in which a single 25-gauge port is inserted into the vitreous cavity transconjunctivally through the upper temporal pars plana. The area of halation around the corneal opacity was significantly smaller in the 29-gauge group than in the 25-gauge group. The reduction in halation improved visibility of the anterior capsule and enabled the surgeon to perform CCC with greater safety. The 29-gauge chandelier system was more suitable than the 25-gauge chandelier system for the non-open-sky CCC component of the PKP triple procedure. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Glaucoma Mini-Shunt Implantation After Keratoplasty.

    PubMed

    Ledesma-Gil, Jasbeth; García-Rodríguez, María de Los Ángeles; Gurria, Lulu U; Graue-Hernández, Enrique O; Navas, Alejandro

    2017-04-01

    To report the outcomes of patients who underwent miniature glaucoma shunt implantation after secondary glaucoma due to keratoplasty. Prospective study of consecutive clinical cases who underwent mini-glaucoma shunt implantation following keratoplasty. In brief, a fornix-based conjunctival flap was performed, approximately 50% thickness scleral flap. Mitomycin C 0.025% placed under Tenon's capsule. A 25-G needle created entry for mini-shunt. Ex-PRESS model P-50 was inserted. Scleral flap and conjunctiva were closed with 10-0 Nylon. STATA 8.0 and SPSS software were used for statistical analysis. Seventeen eyes of 17 patients with a mean age of 39.70 years (SD=18.33, range: 18 to 76). A total of 64.70% were male and 35.30% female. Eleven cases after penetrating keratoplasty, 3 cases after triple procedure, 2 after deep anterior lamellar keratoplasty, and 1 following endothelial keratoplasty. Most of the indications for keratoplasty were keratoconus in 9 cases (52.94%), 4 due to endothelial failure (23.52%), 3 cases of herpetic keratitis (17.64%), and 1 case of post-LASIK ectasia (5.88%). Mean preoperative intraocular pressure was 35.94 mm Hg with maximal medical therapy (SD=9.65, range: 18 to 55). Decreasing intraocular pressure to 12.76 mm Hg postoperatively (SD=2.51, range 10 to 18) (P=0.001). Mean follow-up after mini-glaucoma shunt implantation was 23.76 months (SD=8.73, range: 10 to 35 mo). Preoperative mean uncorrected distance visual acuity (UDVA) was 1.31±0.63 (20/408 Snellen) and postoperative mean UDVA was 0.85±0.40 (20/141 Snellen) (P=0.001). Preoperative mean corrected distance visual acuity (CDVA) was 0.83±0.76 (20/135 Snellen) and postoperative mean CDVA was 0.56±0.44 (20/72 Snellen) (P=0.032). Ex-PRESS miniature glaucoma shunt could be an alternative treatment in postkeratoplasty glaucoma resistant to medical treatment. This technique may be helpful, in trying to avoid corneal damage produced by conventional glaucoma procedures.

  11. Astigmatism Correction With Toric Intraocular Lenses in Descemet Membrane Endothelial Keratoplasty Triple Procedures.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2017-03-01

    To report the clinical efficacy of astigmatism correction with toric intraocular lenses (IOLs) in patients undergoing the Descemet membrane endothelial keratoplasty (DMEK) triple procedure and to evaluate the accuracy of the correction. Fifteen eyes of 10 patients who received cataract extraction, toric IOL placement, and DMEK surgery for Fuchs corneal dystrophy and cataracts were evaluated. The cylinder power of toric IOLs was determined by an online toric calculator with keratoscopy measurements obtained using Scheimpflug corneal imaging. Prediction errors were assessed as a difference vector between the anticipated minus postoperative residual astigmatism. At 10.1 ± 4.9 months postoperatively, 8/13 (61.5%) of eyes achieved uncorrected distance visual acuity better than 20/40. Mean best spectacle-corrected distance visual acuity (logMAR) improved from 0.21 ± 0.15 preoperatively to 0.08 ± 0.12 postoperatively (P < 0.01). The magnitude of refractive astigmatism was also significantly decreased from 2.23 ± 1.10 D (range 0.75-4.25 D) preoperatively to 0.87 ± 0.75 D (range 0.00-3.00 D) postoperatively (P < 0.01). In 1 eye with rotational misalignment by 43 degrees, we found no improvement of astigmatism. The prediction error of astigmatism at the corneal plane was 0.77 ± 0.54 D (range 0.10-1.77 D). Four eyes with preoperative "with-the-rule" corneal astigmatism had postoperative "against-the-rule" refractive astigmatism. For patients with Fuchs corneal dystrophy and cataracts, use of toric IOLs might be a valuable option in triple DMEK surgery. Additionally, care should be taken to prevent excessive IOL rotation.

  12. Evaluation of an interlaced triple procedure: penetrating keratoplasty, extracapsular cataract extraction, and nonopen-sky intraocular lens implantation.

    PubMed

    Yang, Shuo; Wang, Bin; Zhang, Yangyang; Zhai, Hualei; Wang, Junyi; Wang, Shuang; Xie, Lixin

    2017-09-01

    To evaluate an interlaced triple procedure that involved penetrating keratoplasty (PKP), extracapsular cataract extraction (ECCE) using diathermy capsulotomy, and nonopen-sky intraocular lens (IOL) implantation.This retrospective study involved data from 34 patients who were diagnosed with severe corneal opacities and cataracts. These patients were divided into an interlaced procedure group (21 patients) and a traditional procedure group (13 patients). In the interlaced group, the method of continuous curvilinear capsulorhexis (CCC) was completed via diathermy capsulotomy. The donor corneal button was sutured at 8 positions (at equal intervals) using 10-0 nylon sutures, and the IOL was inserted into the capsular bag using a closed anterior chamber approach at the 10:30 to 12 o'clock positions between the sutures. In the traditional group, CCC was completed using side-port capsular forceps, and the IOL was implanted using an open anterior chamber approach.In the interlaced group, the CCC, open-sky, and total operation times were significantly shorter than in the traditional group (P < .05). Neither the best-corrected visual acuity (BCVA) nor corneal endothelial cell density was significantly different between the groups at 1 and 6 months after the operation.This interlaced triple procedure for the treatment of corneal diseases with cataracts appears to be feasible and practical.

  13. Preoperative graft thickness measurements do not influence final BSCVA or speed of vision recovery after descemet stripping automated endothelial keratoplasty.

    PubMed

    Phillips, Paul M; Phillips, Louis J; Maloney, Charlene M

    2013-11-01

    To evaluate the influence of preoperative graft thickness (GT) on final visual acuity and speed of vision recovery after Descemet stripping automated endothelial keratoplasty (DSAEK). The best spectacle-corrected acuity (BSCVA) was measured after DSAEK was performed at 1, 3, 6, 12, and 24 months. A regression analysis was performed to determine whether GT predicted the BSCVA across each time gate. The time to achieve the "1-year maximum BSCVA" was determined to assess the "speed" of recovery for all eyes that had data at 1, 3, 6, and 12 months. Additionally, the final BSCVA was compared between 2 distinct groups of "thin" (<125-μm) versus "thick" (>165-μm) tissue. There were 144 eyes evaluated. No significant correlations were found between the GT and the BSCVA at any of the time gates: 1, 3, 6, 12, or 24 months. Speed of vision recovery was not affected by the GT. The average GT values of the eyes that achieved BSCVA by 1, 3, 6 months and 1 year were not significantly different and were 154.7, 141.3, 149, and 150.1 μm, respectively. No difference was found between the BSCVA of "thick" versus "thin" tissues at any of the time gates: 1, 3, 6, or 12 months. Preoperative GT measurements were not correlated with the BSCVA after the DSAEK was performed at 1, 6, 12, or 24 months postoperatively and do not determine the speed of vision recovery. Additionally, no difference was found in postoperative vision outcomes when directly comparing tissues at either end of the GT spectrum of this study.

  14. Pediatric keratoplasty.

    PubMed

    Vanathi, M; Panda, Anita; Vengayil, Sujith; Chaudhuri, Zia; Dada, Tanuj

    2009-01-01

    Penetrating keratoplasty in children is a highly challenging and demanding procedure associated with a high risk of graft failure or failure of amblyopia therapy in clear grafts. Nonetheless, keratoplasty remains the surgery of choice for the management of pediatric corneal stromal opacities or edema. Allograft rejection, graft infection, corneal neovascularization, glaucoma, trauma to the anterior segment, vitreous pathology, and additional surgical interventions, especially those related to glaucoma management, are important risk factors. Successful penetrating keratoplasty in children requires careful preoperative evaluation and selection of patients follow-up by well-motivated parents, an expert corneal transplant surgeon, and a devoted pediatric ophthalmologist.

  15. Eye-bank preparation of endothelial tissue.

    PubMed

    Boynton, Grace E; Woodward, Maria A

    2014-07-01

    Eye-bank preparation of endothelial tissue for keratoplasty continues to evolve. Although eye-bank personnel have become comfortable and competent at Descemet's stripping automated endothelial keratoplasty (DSAEK), tissue preparation and tissue transport, optimization of preparation methods continues. Surgeons and eye-bank personnel should be up to date on the research in the field. As surgeons transit to Descemet's membrane endothelial keratoplasty (DMEK), eye banks have risen to the challenge of preparing tissue. Eye banks are refining their DMEK preparation and transport techniques. This article covers refinements to DSAEK tissue preparation, innovations to prepare DMEK tissue, and nuances to improve donor cornea tissue quality. As eye bank-supplied corneal tissue is the main source of tissue for many corneal surgeons, it is critical to stay informed about tissue handling and preparation. Ultimately, the surgeon is responsible for the transplantation, so involvement of clinicians in eye-banking practices and advocacy for pursuing meaningful research in this area will benefit clinical patient outcomes.

  16. Eye-bank Preparation of Endothelial Tissue

    PubMed Central

    Boynton, Grace E.; Woodward, Maria A.

    2014-01-01

    Purpose of review Eyebank preparation of endothelial tissue for keratoplasty continues to evolve. While eye bank personnel have become comfortable and competent at Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) tissue preparation and tissue transport, optimization of preparation methods continues. Surgeons and eye bank personnel should be up to date on the research in the field. As surgeons transition to Descemet Membrane Endothelial Keratoplasty (DMEK), eye banks have risen to the challenge of preparing tissue. Eye banks are refining their DMEK preparation and transport techniques Recent findings This article covers refinements to DSAEK tissue preparation, innovations to prepare DMEK tissue, and nuances to improve donor cornea tissue quality. Summary As eye bank supplied corneal tissue is the main source of tissue for many corneal surgeons, it is critical to stay informed about tissue handling and preparation. Ultimately the surgeon is responsible for the transplantation, so involvement of clinicians in eye banking practices and advocacy for pursuing meaningful research in this area will benefit clinical patient outcomes. PMID:24837574

  17. Corneal iron ring after conductive keratoplasty.

    PubMed

    Kymionis, George D; Naoumidi, Tatiana L; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-08-01

    To report formation of corneal iron ring deposits after conductive keratoplasty. Observational case report. Case report. A 54-year-old woman underwent conductive keratoplasty for hyperopia. One year after conductive keratoplasty, iron ring pattern pigmentation was detected at the corneal epithelium of both eyes. This is the first report of the appearance of corneal iron ring deposits following conductive keratoplasty treatment in a patient. It is suggested that alterations in tear film stability, resulting from conductive keratoplasty-induced changes in corneal curvature, constitute the contributory factor for these deposits.

  18. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty.

    PubMed

    Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D

    2018-01-01

    We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  19. Evaluation of Time to Donor Lenticule Apposition Using Intraoperative Optical Coherence Tomography in Descemet Stripping Automated Endothelial Keratoplasty.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Falera, Ruchita; Jose, Cijin P; Sharma, Namrata

    2016-04-01

    To evaluate the time to donor lenticule apposition in cases of Descemet stripping automated endothelial keratoplasty (DSAEK) using microscope-integrated intraoperative optical coherence tomography (iOCT). Thirty eyes of 27 patients planned to undergo Descemet stripping automated endothelial keratoplasty were enrolled in this prospective study. In group I (n = 10), continuous intracameral positive pressure was maintained for 8 minutes. In group II (n = 10) and group III (n = 10), external corneal massage was initiated simultaneously with positive intracameral air pressure. The external corneal massage was continued till complete resolution of interface fluid; the positive intracameral pressure was maintained for 8 minutes in group II and for 5 minutes in group III. The host-donor relationship was continuously monitored with the iOCT. The main outcome measure was time to complete donor lenticule apposition. In group I, the interface fluid persisted after 8 minutes of positive intracameral pressure in all eyes (10/10); hence an external corneal massage was required to achieve optimal donor adherence. In groups II and III, all eyes (20/20) had complete resolution of the interface fluid at the end of 3 minutes. In 100% of the eyes (30/30), the grafts were attached after anterior chamber decompression as seen on the iOCT. In all cases, the donor lenticules were adhered in the postoperative period. iOCT helps in understanding that the donor lenticule is well apposed within 1 to 3 minutes with the technique of simultaneous positive intracameral pressure and external corneal massage. This knowledge minimizes the waiting time for graft apposition and prevents prolonged intraocular pressure elevation.

  20. Efficacy of Chandelier Illumination for Combined Cataract Operation and Penetrating Keratoplasty

    PubMed Central

    Hariya, Takehiro; Uematsu, Megumi; Meguro, Yasuhiko; Kobayashi, Wataru; Nishida, Kohji; Nakazawa, Toru

    2015-01-01

    Purpose: The aim of this study was to describe a method for non–open-sky continuous curvilinear capsulorhexis (CCC) with chandelier retroillumination for penetrating keratoplasty triple procedure and report its effectiveness in decreasing intraoperative complications and enabling successful primary intraocular lens (IOL) insertion in patients with moderate or dense central corneal opacities. Methods: Seventeen eyes of 17 patients were enrolled in this study, divided into a chandelier group, including 7 eyes of 7 patients, and a nonchandelier group, including 10 eyes of 10 patients. In each group, time to achieve CCC (in seconds), open-sky time (in seconds), and operation time (in minutes) were measured, and the rates of successful CCC completion, rupture of the posterior capsule or zonule of Zinn, and successful IOL insertion were recorded. Results: CCC time was not significantly different in both groups. In the chandelier group, however, open-sky time and operation time were significantly shorter than in the nonchandelier group (1429 ± 67 vs. 2016 ± 354 seconds, and 90.4 ± 3.5 vs. 108.9 ± 10.3 minutes, respectively). In the chandelier group, the rate of successful CCC completion was significantly higher than in the nonchandelier group (86% vs. 30%). The rates of posterior capsule or zonule of Zinn rupture and successful IOL insertion were not significantly different (14% vs. 40%, 14% vs. 10%, and 86% vs. 70%, respectively). Conclusions: Non–open-sky CCC with chandelier illumination has many advantages for penetrating keratoplasty triple procedure compared with open-sky CCC without chandelier illumination. PMID:25564335

  1. Donor cross-linking for keratoplasty: a laboratory evaluation.

    PubMed

    Mukherjee, Achyut; Hayes, Sally; Aslanides, Ioannis; Lanchares, Elena; Meek, Keith M

    2015-12-01

    This laboratory-based investigation compares the topographic outcomes of conventional penetrating keratoplasty with that of a novel procedure in which donor corneas are cross-linked prior to keratoplasty. Penetrating keratoplasty procedures with continuous running sutures were carried out in a porcine whole globe model. Sixty eyes were randomly paired as 'donor' and 'host' tissue before being assigned to one of two groups. In the cross-linked group, donor corneas underwent riboflavin/UVA cross-linking prior to being trephined and sutured to untreated hosts. In the conventional keratoplasty group, both host and donor corneas remained untreated prior to keratoplasty. Topographic and corneal wavefront measurements were performed following surgery, and technical aspects of the procedure evaluated. Mean keratometric astigmatism was significantly lower in the cross-linked donor group at 3.67D (SD 1.8 D), vs. 8.43 D (SD 2.4 D) in the conventional keratoplasty group (p < 0.005). Mean wavefront astigmatism was also significantly reduced in the cross-linked donor group 4.71 D (SD 2.1) vs. 8.29D (SD 3.6) in the conventional keratoplasty group (p < 0.005). Mean RMS higher order aberration was significantly lower in the cross-linked donor group at 1.79 um (SD 0.98), vs. 3.05 um (SD 1.9) in the conventional keratoplasty group (P = 0.02). Qualitative analysis revealed less tissue distortion at the graft-host junction in the cross-linked group. Cross-linking of donor corneas prior to keratoplasty reduces intraoperative induced astigmatism and aberrations in an animal model. Further studies are indicated to evaluate the implications of this potential modification of keratoplasty surgery.

  2. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Zafar, Andleeb; Aslanides, Ioannis M.; Selimis, Vasileios; Tsoulnaras, Konstantinos I.; Tabibian, David; Kymionis, George D.

    2018-01-01

    Purpose We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye. PMID:29643797

  3. Cost Minimization Analysis of Precut Cornea Grafts in Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Yong, Kai-Ling; Nguyen, Hai V.; Cajucom-Uy, Howard Y.; Foo, Valencia; Tan, Donald; Finkelstein, Eric A.; Mehta, Jodhbir S.

    2016-01-01

    Abstract Descemet stripping automated endothelial keratoplasty (DSAEK) is the most common corneal transplant procedure. A key step in the procedure is preparing the donor cornea for transplantation. This can be accomplished via 1 of 3 alternatives: surgeon cuts the cornea on the day of surgery, the cornea is precut ahead of time in an offsite facility by a trained technician, or a precut cornea is purchased from an eye bank. Currently, there is little evidence on the costs and effectiveness of these 3 strategies to allow healthcare providers decide upon the preferred method to prepare grafts. The aim of this study was to compare the costs and relative effectiveness of each strategy. The Singapore National Eye Centre and Singapore Eye Bank performed both precut cornea and surgeon-cut cornea transplant services between 2009 and 2013. This study included 110 subjects who received precut cornea and 140 who received surgeon-cut cornea. Clinical outcomes and surgical duration were compared across the strategies using the propensity score matching. The cost of each strategy was estimated using the microcosting and consisted of facility costs and procedural costs including surgical duration. One-way sensitivity analysis and threshold analysis were performed. The cost for DSAEK was highest for the surgeon-cut approach ($13,965 per procedure), followed by purchasing precut corneas ($12,659) and then setting up precutting ($12,421). The higher procedural cost of the surgeon-cut approach was largely due to the longer duration of the procedure (surgeon-cut = 72.54 minutes, precut = 59.45 minutes, P < 0.001) and the higher surgeon fees. There was no evidence of differences in clinical outcomes between grafts that were precut or surgeon-cut. Threshold analysis demonstrated that if the number of cases was below 31 a year, the strategy that yielded the lowest cost was purchasing precut cornea from eye bank. If there were more than 290 cases annually, the cheapest

  4. Histopathologic analysis of successful endothelial keratoplasty following multiple failed keratoplasties.

    PubMed

    Epstein, Rachel H; Mamalis, Nick; Price, Francis W; Price, Marianne O

    2015-02-01

    A 68-year-old woman with bilateral keratoconus presented with persistent visual acuity deficits following cataract extraction with a neodymium:YAG capsulotomy in the right eye 2 years earlier. Penetrating keratoplasty (PKP) had been performed for keratoconus in the right eye without complications until steroid drops were discontinued after 10 years because of persistent elevated intraocular pressure. The right eye experienced immunologic rejection and failure of 3 PKPs, 1 Descemet-stripping endothelial keratoplasty (DSEK), and a trabeculectomy with an eventual anatomically successful DSEK before the patient died at 95 years of age. The left eye improved following a single PKP. Postmortem histopathologic analysis of the cornea showed an anatomically successful DSEK graft with intact donor Descemet membrane and viable graft endothelial cells. To our knowledge, this is the first histopathologic analysis of an anatomically successful DSEK after multiple failed PKPs and trabeculectomy. The course in this case supports early consideration of lamellar keratoplasty, especially in patients with ocular comorbidities. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Cornea Preservation Time Study: Methods and Potential Impact on the Cornea Donor Pool in the United States

    PubMed Central

    Szczotka-Flynn, Loretta B.; Ayala, Allison R.; Benetz, Beth A.; Gal, Robin L.; Aldave, Anthony J.; Corrigan, Michelle M.; Dunn, Steven P.; McCall, Ty L.; Pramanik, Sudeep; Rosenwasser, George O.; Ross, Kevin W.; Terry, Mark A.; Verdier, David D.

    2015-01-01

    Purpose: The aim of this study was to describe the aims, methods, donor and recipient cohort characteristics, and potential impact of the Cornea Preservation Time Study (CPTS). Methods: The CPTS is a randomized clinical trial conducted at 40 clinical sites (70 surgeons) designed to assess the effect of donor cornea preservation time (PT) on graft survival 3 years after Descemet stripping automated endothelial keratoplasty (DSAEK). Eyes undergoing surgery for Fuchs endothelial corneal dystrophy or pseudophakic/aphakic corneal edema were randomized to receive donor corneas stored ≤7 days or 8 to 14 days. Donor and patient characteristics, tissue preparation and surgical parameters, recipient and donor corneal stroma clarity, central corneal thickness, intraocular pressure, complications, and a reading center-determined central endothelial cell density were collected. Surveys were conducted to evaluate pre-CPTS PT practices. Results: The 1330 CPTS donors were: 49% >60 years old, 27% diabetic, had a median eye bank–determined screening endothelial cell density of 2688 cells/mm2, and 74% eye bank prepared for DSAEK. A total of 1090 recipients (1330 eyes including 240 bilateral cases) had: median age of 70 years, were 60% female, 90% white, 18% diabetic, 52% phakic, and 94% had Fuchs endothelial corneal dystrophy. Before the CPTS, 19 eye banks provided PT data on 20,852 corneas domestically placed for DSAEK in 2010 to 2011; 96% were preserved ≤7 days. Of 305 American Academy of Ophthalmology members responding to a pre-CPTS survey, 233 (76%) set their maximum PT preference at 8 days or less. Conclusions: The CPTS will increase understanding of factors related to DSAEK success and, if noninferiority of longer PT is shown, will have great potential to extend the available pool of endothelial keratoplasty donors. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT01537393. PMID:25850706

  6. Air-guided manual deep lamellar keratoplasty.

    PubMed

    Caporossi, A; Simi, C; Licignano, R; Traversi, C; Balestrazzi, A

    2004-01-01

    To evaluate the efficacy of a new modified technique of deep lamellar keratoplasty (DLK). Nine eyes of eight patients with keratoconus of moderate degree were included. All patients underwent DLK with manual dissection from a limbal side port after an air bubble injection in the anterior chamber. The patients underwent a complete ophthalmologic examination 6 months after the suture removal, evaluating best-corrected visual acuity, corneal thickness, endothelial cell count, and topographic astigmatism. One case (11.1%) was converted to penetrating keratoplasty because of microperforation. In the eight successful cases, 7 eyes (77.8%) achieved 20/30 or better visual acuity 6 months after suture removal. Mean postoperative pachymetry was 604.76 microm (SD 46.76). Specular microscopy 6 months after suture removal revealed average endothelial cell count of 2273/mm2 (SD 229). This modified DLK technique is a safe and effective procedure and could facilitate, after a short learning curve, this kind of surgery with a low risk of conversion to penetrating keratoplasty.

  7. Combined keratoplasty and cataract extraction.

    PubMed

    Demeler, U; Hinzpeter, E N

    1977-04-01

    A short film showing our technique of combined penetrating keratoplasty and intracapsular cataract extraction was shown, and the postoperative results in 72 eyes after an average of 3 years were reported.

  8. Corneal lenticular wrinkling after automated lamellar keratoplasty.

    PubMed

    Steinemann, T L; Denton, N C; Brown, M F

    1998-10-01

    To report complications of automated lamellar keratoplasty in two eyes of two patients. Case reports. Two eyes of two patients underwent automated lamellar keratoplasty for myopia. Both patients complained of visual distortion and glare in the postoperative eye. The postoperative eye of both patients showed evidence of wrinkling of the corneal lenticule accompanied by irregular astigmatism. Patient 1 showed persistent lenticular wrinkling and corneal scarring 2.5 years later. Patient 2 showed evidence of interface scar and overcorrection. The use of a microkeratome can be complicated by lenticular displacement and wrinkling, resulting in visual aberration for the patient.

  9. Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

    PubMed

    Greenlee, Emily C; Kwon, Young H

    2008-06-01

    Glaucoma after penetrating keratoplasty is a frequently observed post-operative complication and is a risk factor for graft failure. Penetrating keratoplasty performed for aphakic and pseudophakic bullous keratopathy and inflammatory conditions are more likely to cause postoperative glaucoma compared with keratoconus and Fuchs' endothelial dystrophy. The intraocular pressure elevation may occur immediately after surgery or in the early to late postoperative period. Early postoperative causes of glaucoma include pre-existing glaucoma, retained viscoelastic, hyphema, inflammation, pupillary block, aqueous misdirection, or suprachoroidal hemorrhage. Late causes include pre-existing glaucoma, angle-closure glaucoma, ghost cell glaucoma, suprachoroidal hemorrhage, and steroid-induced glaucoma. Determining the cause of IOP elevation can help guide therapeutic intervention. Treatments for refractory glaucoma include topical anti-glaucoma medications such as beta-adrenergic blockers. Topical carbonic anhydrase inhibitors, miotic agents, adrenergic agonists, and prostaglandin analogs should be used with caution in the post-keratoplasty patient, because of the possibility of corneal decompensation, cystoid macular edema, or persistent inflammation. Various glaucoma surgical treatments have reported success in post-keratoplasty glaucoma. Trabeculectomy with mitomycin C can be successful in controlling IOP without the corneal toxicity noted with 5-fluorouracil. Glaucoma drainage devices have successfully controlled intraocular pressure in postkeratoplasty glaucoma; this is, however, associated with increased risk of graft failure. Placement of the tube through the pars plana may improve graft success compared with implantation within the anterior chamber. In addition, cyclophotocoagulation remains a useful procedure for eyes that have refractory glaucoma despite multiple surgical interventions.

  10. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  11. Penetrating keratoplasty in infancy and early childhood.

    PubMed

    Reidy, J J

    2001-08-01

    Penetrating keratoplasty in infants and young children is performed on an infrequent basis. The most common indication is visually significant congenital corneal opacity. Surgery must be performed early to avoid amblyopia. Surgical techniques differ from those used in adult penetrating keratoplasty because of the reduced ocular rigidity encountered in infants and young children. Use of a multispecialty team approach is important to improve visual outcome. Poor prognostic indicators include bilateral disease, concomitant infantile glaucoma, lensectomy and vitrectomy at the time of surgery, previous graft failure, extensive goniosynechiae, and extensive corneal vascularization. Prompt postoperative optical rehabilitation, combined with occlusion therapy when appropriate, is an important determinant of success.

  12. Accuracy of Corneal Thickness by Swept-Source Optical Coherence Tomography and Scheimpflug Camera in Virgin and Treated Fuchs Endothelial Dystrophy.

    PubMed

    Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana

    2018-06-01

    To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.

  13. Development of a nomogram for femtosecond laser astigmatic keratotomy for astigmatism after keratoplasty.

    PubMed

    St Clair, Ryan M; Sharma, Anushree; Huang, David; Yu, Fei; Goldich, Yakov; Rootman, David; Yoo, Sonia; Cabot, Florence; Jun, Jason; Zhang, Lijun; Aldave, Anthony J

    2016-04-01

    To develop a nomogram for femtosecond laser astigmatic keratotomy (AK) to treat post-keratoplasty astigmatism. Three academic medical centers. Retrospective interventional case series. A review of post-keratoplasty femtosecond laser AK was performed. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and keratometry were recorded preoperatively and 1, 3, 6, and 12 months postoperatively. The location, length, depth, and diameter of the AK incisions were recorded, and the surgically induced astigmatic correction was related to these variables using regression analysis. One hundred forty femtosecond laser AK procedures were performed after penetrating keratoplasty (PKP) (n = 129) or deep anterior lamellar keratoplasty (DALK) (n =11), with 89 procedures (80 PKP, 9 DALK) included in the analysis. The mean CDVA improved from 20/59 (0.47 logMAR ± 0.38 [SD]) preoperatively to 20/45 (0.35 ± 0.31 logMAR) postoperatively (P = .013) (n = 46). The mean keratometric astigmatism decreased from 8.26 ± 2.90 diopters (D) preoperatively to 3.62 ± 2.59 D postoperatively (P < .0001) (n = 89). The mean refractive cylinder decreased from 6.77 ± 2.80 D preoperatively to 2.85 ± 2.57 D postoperatively (P < .0001) (n = 69). A nomogram for femtosecond laser AK to treat post-keratoplasty astigmatism was generated using regression analysis. Femtosecond laser AK significantly improved UDVA and CDVA and significantly reduced keratometric astigmatism and refractive cylinder after keratoplasty. The nomogram generated should improve the accuracy of post-keratoplasty femtosecond laser AK. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Fuchs' dystrophy associated with radial keratotomy: Lamellar or perforating keratoplasty?

    PubMed

    Rodriguez-Ausin, P; Antolin-Garcia, D; Santamaria Garcia, L; Blazquez-Fernandez, A-B

    2017-05-01

    A 70 year-old male patient with a history of radial keratotomy suffering from Fuchs' dystrophy and a cataract. The patient received a two-step surgery: lens phacoemulsification and intraocular lens implant, followed by descemet stripping automated endothelial keratoplasty in both eyes, four months later. There were no complications apart from a recurrent cystoid macular oedema in both eyes. The best corrected visual acuity was 20/40 both eyes, and the patient was satisfied. Descemet stripping automated endothelial keratoplasty may be considered as an alternative to penetrating keratoplasty in the case of endothelial dysfunction and radial keratotomy in patients with no corneal ectasia or significant stromal opacity. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Post-keratoplasty astigmatism management by relaxing incisions: a systematic review.

    PubMed

    Ho Wang Yin, Gaëlle; Hoffart, Louis

    2017-01-01

    Postoperative visual acuity can be limited by post-keratoplasty astigmatism, even with a clear corneal graft. Astigmatism management can be performed by selective suture removal, adjustment of sutures, optical correction, photorefractive procedures, wedge resection, intra-ocular lens implantation, intracorneal ring segments, relaxing incisions with or without compression sutures and repeated keratoplasty. Relaxing incisions can be made in the graft, graft-host interface or host cornea. Despite the unpredictability of the method because the flat and steep meridians are usually not orthogonal after penetrating keratoplasty, with asymmetric power distribution, all the studies showed an overall reduction of refractive, keratometric or topographic astigmatism, ranging from 30% to 72% with manual or femtosecond-assisted techniques. Most patients with astigmatism higher than 6 diopters had residual cylinder less than or equal to 3 diopters, which can be treated by laser excimer ablation or secondary intraocular lens implantation.

  16. Fixed dilated pupil (Urrets-Zavalia syndrome) after air/gas injection after deep lamellar keratoplasty for keratoconus.

    PubMed

    Maurino, Vincenzo; Allan, Bruce D S; Stevens, Julian D; Tuft, Stephen J

    2002-02-01

    To describe three cases of fixed dilated pupil and presumed iris ischemia (Urrets-Zavalia syndrome) after anterior chamber air/gas injection after deep lamellar keratoplasty for keratoconus. Interventional case series. Three eyes of three patients with keratoconus underwent deep lamellar keratoplasty and intraoperative or postoperative injection of air/gas in the anterior chamber to appose the host-donor lamellar graft interface. Urrets-Zavalia syndrome was diagnosed on clinical grounds in three cases and was associated with the Descemet membrane microperforation intraoperatively and introduction of air/gas into the anterior chamber intraoperatively or postoperatively. A fixed dilated pupil is an uncommon complication of penetrating keratoplasty for keratoconus that can also develop after deep lamellar keratoplasty. Leaving an air or gas bubble in the anterior chamber of a phakic eye after deep lamellar keratoplasty is a risk factor and should therefore be avoided.

  17. Eye bank tissue utilization between endothelial keratoplasty and penetrating keratoplasty.

    PubMed

    Croasdale, Christopher R; Barney, Erin; Warner, Evan J

    2013-03-01

    To determine rates of tissue use for corneal transplants via endothelial keratoplasty (EK) relative to penetrating keratoplasty (PK). Retrospective chart review of all cornea tissues (n = 3669) distributed from the Lions Eye Bank of Wisconsin for EK or PK from August 1, 2004 through July 31, 2009 (60 months). Rates of tissue use for EK relative to PK were determined both on a yearly basis and for the overall study period. Replacement frequency and time to subsequent surgery were established for each group. Donor tissue and recipient characteristics were compared between groups. Donor characteristics did not differ between the 2 groups; 11.9% of EK tissues failed and were replaced during the study period compared with 5.1% of PK tissues (P < 0.0001). Additional tissue for the same eye came at a mean of 174 days after an EK surgery compared with 558 days after a PK (P < 0.0001). Surgeons requesting tissue for EK increased each year, whereas the number of repeat tissue requests decreased over time. Additional tissues were required for recipients of EK more than twice as often as for recipients of PK, and replacement of EK grafts occurred at a mean of more than 1 year before replacement of PK grafts. This pattern of tissue utilization during the first 5 years of distribution for EK did not negatively affect the Lions Eye Bank of Wisconsin from meeting the surgeon demand for tissue in its service area. Eye banks may wish to monitor tissue utilization as part of their quality assurance program.

  18. Descemet Membrane Endothelial Keratoplasty After Penetrating Keratoplasty: Features for Success.

    PubMed

    Einan-Lifshitz, Adi; Belkin, Avner; Sorkin, Nir; Mednick, Zale; Boutin, Tanguy; Gill, Ishrat; Karimi, Mohammad; Chan, Clara C; Rootman, David S

    2018-05-08

    To evaluate Descemet membrane endothelial keratoplasty (DMEK) in the setting of failed penetrating keratoplasty (PKP) and to identify factors associated with DMEK success and failure after PKP. A retrospective chart review of patients who underwent DMEK for failed PKP at Toronto Western Hospital, Canada, between 2014 and 2017 was performed. Demographic characteristics, number of previous transplants, intraoperative and postoperative complications, best spectacle-corrected visual acuity (BSCVA), and endothelial cell density were analyzed. Twenty-eight eyes were included in the study. Rebubbling intervention was performed in 12 eyes (43%) within the first postoperative weeks. Five eyes (18%) developed graft rejection episodes. Twelve eyes (43%) had to be regrafted after DMEK surgery and were deemed failures (because of persistent Descemet membrane detachment, rejection episode that led to secondary failure, and infection). BSCVA before DMEK was significantly worse in the eyes that failed than those that did not [1.97 ± 0.85 and 1.2 ± 0.56 logMAR, respectively, (P = 0.01)]. Rebubbling was required in 75% of eyes in the failure group compared with 19% in the success group (P = 0.002). Six of the 16 eyes (37.5%) in the success group underwent femtosecond laser-enabled DMEK, whereas this technique was not used in any of the eyes in the failure group (P = 0.017). DMEK is a viable option for cases of failed PKP. DMEK failure after PKP might be associated with lower visual acuity before DMEK surgery, higher number of rebubble interventions, and manual descemetorhexis rather than femtosecond laser-enabled DMEK.

  19. Laser in situ keratomileusis for residual hyperopic astigmatism after conductive keratoplasty.

    PubMed

    Kymionis, George D; Aslanides, Ioannis M; Khoury, Aghlab N; Markomanolakis, Marinos M; Naoumidi, Tatiana; Pallikaris, loannis G

    2004-01-01

    To report a case of laser in situ keratomileusis (LASIK) in a patient with previous conductive keratoplasty. A 48-year-old man underwent conductive keratoplasty for low hyperopic astigmatism (manifest refraction OD: +2.25 -0.50 x 77 degrees; OS: +2.50 -0.50 x 105 degrees). Three months postoperatively, UCVA was 20/25 and BSCVA was 20/20 in both eyes; manifest refraction OD: -0.25 -0.75 x 110 degrees; OS: +0.75 -0.75 x 50 degrees. Sixteen months after the operation, regression of refractive outcome was (manifest) OD: +1.75 -1.25 x 90 degrees; OS: +2.50 -0.50 x 85 degrees; UCVA was 20/40 in the right eye and 20/63 in the left eye and BSCVA was 20/20 in both eyes. LASIK was performed for hyperopic regression in the left eye using an automated microkeratome (Alcon SKBM, 130-microm plate; Aesculap-Meditec MEL 70 excimer laser). LASIK was uneventful and no intraoperative or postoperative complications related to the previous conductive keratoplasty procedure or LASIK were observed. Three months after LASIK and 19 months after the initial conductive keratoplasty, the patient's left eye was emmetropic; UCVA was 20/20(-2), BSCVA was 20/20 and manifest refraction was +0.25 -0.25 x 35 degrees. There was a uniform increase in topographical steepening. Visual acuity, refraction and topographic findings remained unchanged at 6 months. Even though our experience is limited, treatment of hyperopia with LASIK in an eye with refractive regression following previous conductive keratoplasty resulted in a predicted refractive outcome, with no complications, and improvement in visual acuity at 6 months follow-up.

  20. A comparison of lamellar and penetrating keratoplasty outcomes: a registry study.

    PubMed

    Coster, Douglas J; Lowe, Marie T; Keane, Miriam C; Williams, Keryn A

    2014-05-01

    To investigate changing patterns of practice of keratoplasty in Australia, graft survival, visual outcomes, the influence of experience, and the surgeon learning curve for endothelial keratoplasty. Observational, prospective cohort study. From a long-standing national corneal transplantation register, 13 920 penetrating keratoplasties, 858 deep anterior lamellar keratoplasties (DALKs), and 2287 endokeratoplasties performed between January 1996 and February 2013 were identified. Kaplan-Meier functions were used to assess graft survival and surgeon experience, the Pearson chi-square test was used to compare visual acuities, and linear regression was used to examine learning curves. Graft survival. The total number of corneal grafts performed annually is increasing steadily. More DALKs but fewer penetrating grafts are being performed for keratoconus, and more endokeratoplasties but fewer penetrating grafts are being performed for Fuchs' dystrophy and pseudophakic bullous keratopathy. In 2012, 1482 grafts were performed, compared with 955 in 2002, translating to a requirement for 264 extra corneal donors across the country in 2012. Comparing penetrating grafts and DALKs performed for keratoconus over the same era, both graft survival (P <0.001) and visual outcomes (P <0.001) were significantly better for penetrating grafts. Survival of endokeratoplasties performed for Fuchs' dystrophy or pseudophakic bullous keratopathy was poorer than survival of penetrating grafts for the same indications over the same era (P <0.001). Visual outcomes were significantly better for penetrating grafts than for endokeratoplasties performed for Fuchs' dystrophy (P <0.001), but endokeratoplasties achieved better visual outcomes than penetrating grafts for pseudophakic bullous keratopathy (P <0.001). Experienced surgeons (>100 registered keratoplasties) achieved significantly better survival of endokeratoplasties (P <0.001) than surgeons who had performed fewer grafts (<100

  1. Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device

    PubMed Central

    Modis, Laszlo; Hassan, Ziad; Szalai, Eszter; Flaskó, Zsuzsanna; Berta, Andras; Nemeth, Gabor

    2016-01-01

    AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43±21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41±40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. PMID:26949641

  2. Deep lamellar keratoplasty on air with lyophilised tissue.

    PubMed Central

    Chau, G K; Dilly, S A; Sheard, C E; Rostron, C K

    1992-01-01

    Deep lamellar keratoplasty on air involves injecting air into the corneal stroma to expand it to several times its normal thickness. This method is designed to facilitate dissection of the deep stroma and reduce the risk of perforation of Descemet's membrane when carrying out deep lamellar keratoplasty. We have modified the technique by using prelathed freeze-dried donor tissue and report our results in a series of patients with corneal stromal scarring owing to a variety of corneal problems, namely, keratoconus, pterygium, and herpes zoster ophthalmicus. All patients achieved best corrected postoperative visual acuity of 6/12 or better without problems associated with graft failure or rejection. Histopathological examination of corneal tissue following air injection showed surgical emphysema within the cornea and separation of deep stromal fibres from the underlying Descemet's membrane. Images PMID:1477037

  3. Indications and Visual Outcome of Penetrating Keratoplasty in Tertiary Eye Care Institute in Uttarakhand

    PubMed Central

    Gupta, Neeti; Dhasmana, Renu; Nagpal, Ramesh Chander; Bahadur, Harsh; Maitreya, Amit

    2016-01-01

    Introduction Corneal blindness forms significant proportion of visual blindness in developing countries and penetrating keratoplasty (PK) can restore vision for this. The prognosis of PK is dependent on the corneal diseases responsible for corneal blindness. Aim To evaluate the indications and visual outcome of PK in tertiary eye care institute in Uttarakhand. Materials and Methods Data was reviewed from the medical records of 145 PK done in Department of Ophthalmology, Himalayan Institute of Medical Sciences from January 2012 to October 2014. Analysis of data was done for evaluation of the indications and visual outcome by Paired student’s t-test for hypothesis testing of grouped values of preoperative and last follow-up best corrected visual acuity in cases of optical and therapeutic grafts. A p-value < 0.05 was considered statistically significant. Results In this study data of 145 eyes of 138 patients was reviewed. The most common indication for keratoplasty was corneal scarring including adherent leucoma 48 (33.10%). Therapeutic keratoplasty was done for 33 cases with maximum 30(20.68%) cases of infectious keratitis. One case of tectonic graft was included in therapeutic keratoplasty group for analysis. There was statistically significant difference (p=.0001) in best corrected visual acuity improvement from 1.39 logMAR+ 0.022(SD) preoperatively to 0.367 logMAR+0.44(SD) postoperatively and 1.4 logMAR+.000(SD) preoperatively to 0.16 logMAR+0.57(SD) postoperatively for optical and therapeutic grafts respectively. Conclusion Infective keratitis either active or healed was the major indication for keratoplasty. Poor prognosis indications were most common in this part of the country. The visual outcome following corneal transplantation was encouraging particularly in cases of optical keratoplasty. PMID:27504319

  4. Corneal electrolysis for recurrence of corneal stromal dystrophy after keratoplasty

    PubMed Central

    Mashima, Y; Kawai, M; Yamada, M

    2002-01-01

    Aims: To evaluate corneal electrolysis as a treatment for recurrent diffuse corneal opacities at the host-graft interface of the stroma or at the subepithelial region in two types of granular corneal dystrophy (GCD). Methods: Recurrence developed at the host-graft interface of the stroma after lamellar keratoplasty in a patient with Avellino corneal dystrophy (ACD). At surgery, the deep aspect of the graft in this patient was partially separated from host tissue to expose the deposits, with one third of the host-graft junction left intact. The graft was everted, and electrolysis was applied directly to remove the deposits attached to both surfaces of the host and the graft. Then the graft was returned to its place and sutured. In two patients with homozygous ACD and one patient with the superficial variant of GCD, diffuse subepithelial opacities developed following penetrating keratoplasty. Electrolysis was applied directly to the corneal surface. Results: Deposits at the host-graft interface of the stroma and in the subepithelial region disappeared following treatment, and vision recovered in all patients. Conclusions: This method is a simple, easy, and inexpensive way to remove deposits that recur after lamellar or penetrating keratoplasty. PMID:11864880

  5. Corneal electrolysis for recurrence of corneal stromal dystrophy after keratoplasty.

    PubMed

    Mashima, Y; Kawai, M; Yamada, M

    2002-03-01

    To evaluate corneal electrolysis as a treatment for recurrent diffuse corneal opacities at the host-graft interface of the stroma or at the subepithelial region in two types of granular corneal dystrophy (GCD). Recurrence developed at the host-graft interface of the stroma after lamellar keratoplasty in a patient with Avellino corneal dystrophy (ACD). At surgery, the deep aspect of the graft in this patient was partially separated from host tissue to expose the deposits, with one third of the host-graft junction left intact. The graft was everted, and electrolysis was applied directly to remove the deposits attached to both surfaces of the host and the graft. Then the graft was returned to its place and sutured. In two patients with homozygous ACD and one patient with the superficial variant of GCD, diffuse subepithelial opacities developed following penetrating keratoplasty. Electrolysis was applied directly to the corneal surface. Deposits at the host-graft interface of the stroma and in the subepithelial region disappeared following treatment, and vision recovered in all patients. This method is a simple, easy, and inexpensive way to remove deposits that recur after lamellar or penetrating keratoplasty.

  6. Endophthalmitis after penetrating keratoplasty: microbiologic spectrum and susceptibility of isolates.

    PubMed

    Kunimoto, Derek Y; Tasman, William; Rapuano, Christopher; Recchia, Franco; Busbee, Brandon; Pearlman, Robert; Belmont, Jonathan; Cohen, Elisabeth; Vander, James; Laibson, Peter; Raber, Irving

    2004-02-01

    To present the microbial spectrum and susceptibilities of isolates in endophthalmitis following penetrating keratoplasty. Interventional case series. The 1,074 consecutive cases of endophthalmitis presenting to Wills Eye Hospital between 1989 and 2000 were reviewed. Fourteen patients with endophthalmitis after penetrating keratoplasty were identified, and vitreous biopsy isolates from these patients were examined. Eleven (78.6%) of 14 vitreous samples were culture-positive, and two others (14.3%) had organisms viewed on pathology specimen, for a total of 13 (92.9%) organism-proven cases of endophthalmitis. Isolates included 10 (76.9%) gram-positive cocci (six Streptococcus sp., three Staphylococcus sp., one identified on pathology specimen only) and three (23.1%) gram-negative organisms (Proteus mirabilis, Serratia marcescens, one identified on pathology specimen only). Susceptibilities to organism-appropriate antibiotic testing are reported, including cefazolin (six of eight, 75.0%), ciprofloxacin (four of seven, 57.1%), nafcillin (four of six, 66.7%), and vancomycin (seven of seven, 100.0%). This is the largest series on microbial susceptibilities in postpenetrating keratoplasty endophthalmitis. We report a high percentage of culture-positivity, and a high incidence of gram-positive species, and in particular Streptococcus species, with all tested gram-positive organisms susceptible to vancomycin.

  7. Boston type 1 keratoprosthesis for failed keratoplasty.

    PubMed

    Hager, Jonathan L; Phillips, David L; Goins, Kenneth M; Kitzmann, Anna S; Greiner, Mark A; Cohen, Alex W; Welder, Jeffrey D; Wagoner, Michael D

    2016-02-01

    The purpose of this study was to evaluate the outcomes of the Boston type 1 keratoprosthesis (Kpro-1) in eyes with failed keratoplasty. A retrospective review was performed of every patient treated with a Kpro-1 at a tertiary eye care center between January 1, 2008 and July 1, 2013. Eyes with a failed keratoplasty originally performed for corneal edema, trauma, or keratoconus were included in the statistical analysis. The main outcome measures were visual outcome, prosthesis retention, and postoperative complications. Twenty-four eyes met the inclusion criteria, including 13 eyes with corneal edema, 8 eyes with trauma, and 3 eyes with keratoconus. After a mean follow-up period of 28.9 months (range 7-63 months), the median best corrected visual acuity (BCVA) was 20/125. The BCVA was ≥ 20/40 in 4 (16.7 %) eyes, ≥ 20/70 in 9 (37.5 %) eyes, and ≥ 20/200 in 14 (58.3 %) eyes. Overall, the postoperative BCVA improved in 17 (70.9 %) eyes, was unchanged in 3 (12.5 %) eyes, and was worse in 4 (16.7 %) eyes. The initial Kpro-1 was retained in 22 (91.7 %) eyes, and was successfully repeated in the other 2 eyes. One or more serious prosthesis- or sight-threatening complications occurred in 8 (33.3 %) eyes. These included 1 case of wound dehiscence leading to prosthesis extrusion, 1 case of fungal keratitis leading to prosthesis extrusion, 4 cases of endophthalmitis, and 5 retinal detachments. The Boston Kpro-1 is associated with an excellent prognosis for prosthesis retention and satisfactory visual improvement in eyes with previous failed keratoplasty.

  8. Corona sign: manifestation of peripheral corneal epithelial edema as a possible marker of the progression of corneal endothelial dysfunction.

    PubMed

    Inoue, Tomoyuki; Hara, Yuko; Kobayashi, Takeshi; Zheng, Xiaodong; Suzuki, Takashi; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-09-01

    To describe a characteristic form of the corona sign and its clinical relevance to the degree of corneal endothelial decompensation and investigate the underlying mechanism using a rabbit model. These observational cases include 31 patients undergoing penetrating keratoplasty (PKP) and 15 patients undergoing Descemet stripping automated endothelial keratoplasty (DSAEK) with special attention to the circumferentially developed corneal epithelial edema. We also conducted a laboratory observation of horizontal water flow in the rabbit cornea. We consistently observed the corona sign at the superior periphery during the initial stage of corneal endothelial decompensation after PKP. With progressive corneal endothelial cellular loss, the epithelial edema gradually expanded circumferentially in the periphery. The endothelial cellular density associated with the corona sign significantly (P < 0.01) decreased compared with that without the sign. The endothelial cellular density decreased significantly (P < 0.05) in cases with a circumferential corona sign compared with a superior corona sign. After DSAEK, however, the corneal epithelial edema subsided from the center but persisted peripherally as a corona sign in all cases. By 3 months postoperatively, the epithelial edema was confined to the superior periphery along with uneventful corneal endothelial healing. Rabbit experiments showed that total corneal endothelial decompensation decreased the horizontal intracorneal water migration (Inoue-Ohashi phenomenon) in the corneal periphery and induced peripheral corneal edema. The slit-lamp microscopic findings of the corona-like epithelial edema in the peripheral cornea are associated with the stage of corneal endothelial function. To support this, the developmental mechanism of the corona sign was demonstrated experimentally.

  9. The value-based medicine comparative effectiveness and cost-effectiveness of penetrating keratoplasty for keratoconus.

    PubMed

    Roe, Richard H; Lass, Jonathan H; Brown, Gary C; Brown, Melissa M

    2008-10-01

    To perform a base case, comparative effectiveness, and cost-effectiveness (cost-utility) analysis of penetrating keratoplasty for patients with severe keratoconus. Visual acuity data were obtained from a large, retrospective multicenter study in which patients with keratoconus with less than 20/40 best corrected visual acuity and/or the inability to wear contact lenses underwent penetrating keratoplasty, with an average follow-up of 2.1 years. The results were combined with other retrospective studies investigating complication rates of penetrating keratoplasty. The data were then incorporated into a cost-utility model using patient preference-based, time trade-off utilities, computer-based decision analysis, and a net present value model to account for the time value of outcomes and money. The comparative effectiveness of the intervention is expressed in quality-of-life gain and QALYs (quality-adjusted life-years), and the cost-effectiveness results are expressed in the outcome of $/QALY (dollars spent per QALY). Penetrating keratoplasty in 1 eye for patients with severe keratoconus results in a comparative effectiveness (value gain) of 16.5% improvement in quality of life every day over the 44-year life expectancy of the average patient with severe keratoconus. Discounting the total value gain of 5.36 QALYs at a 3% annual discount rate yields 3.05 QALYs gained. The incremental cost for penetrating keratoplasty, including all complications, is $5934 ($5913 discounted at 3% per year). Thus, the incremental cost-utility (discounted at 3% annually) for this intervention is $5913/3.05 QALYs = $1942/QALY. If both eyes undergo corneal transplant, the total discounted value gain is 30% and the overall cost-utility is $2003. Surgery on the second eye confers a total discounted value gain of 2.5 QALYs, yielding a quality-of-life gain of 11.6% and a discounted cost-utility of $2238/QALY. Penetrating keratoplasty for patients with severe keratoconus seems to be a

  10. Association between culture results of corneal scrapings and culture and histopathology results of corneal tissues in therapeutic keratoplasty.

    PubMed

    Das, Sujata; Sharma, Savitri; Priyadarshini, Omega; Sahu, Srikant K; Kar, Sarita; Vemuganti, Geeta K

    2011-09-01

    To correlate the culture results of corneal scrapings with culture and histopathology results of corneal tissues in therapeutic keratoplasty. A retrospective analysis of the culture results of corneal scrapings and corneal tissues of eyes that received therapeutic penetrating keratoplasty at a tertiary eye care center between December 2006 and November 2008 was conducted. As per the preferred practice, those cases that did not respond to appropriate antimicrobial therapy and/or presented with a large infiltrate/perforation received therapeutic keratoplasty. The microbiology and histopathology findings of the corneal tissues were compared. Thirty-eight therapeutic keratoplasties were performed on 36 patients. Although all cases had histopathology and culture of the corneal tissue, corneal scrapings were not performed in 4 cases. Corneal scrapings and corneal tissues were culture-positive in 76% (26 of 34) and 60% (23 of 38) of cases, respectively. In 8 cases, the corneal scrapings and corneal tissues yielded identical organisms, whereas different organisms grew in 4 cases. In 6 cases, the corneal tissues were culture-positive but the corneal scrapings were sterile. In 20 cases, the corneal tissues were culture-positive for fungus and also showed fungal filaments in their corresponding histopathology specimens. Corneal tissue culture can provide additional information in cases undergoing therapeutic keratoplasty. It helps to determine the management of patients after keratoplasty.

  11. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    PubMed

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  12. Chandelier Illumination for Descemet Membrane Endothelial Keratoplasty

    PubMed Central

    Hayashi, Takahiko; Yuda, Kentaro; Tsuchiya, Ayako; Oyakawa, Itaru; Mizuki, Nobuhisa; Kato, Naoko

    2017-01-01

    Purpose: To describe a simple technique that uses posterior chandelier illumination during Descemet membrane endothelial keratoplasty in cases of severe bullous keratopathy (BK). Methods: Five eyes of 4 patients with advanced BK undergoing Descemet membrane endothelial keratoplasty were retrospectively analyzed. The pupil of the host eye was not treated with mydriatic or miotic agents. The chandelier illuminator was inserted transconjunctivally into the vitreous cavity from the pars plana. Results: In all eyes, BK was secondary to laser iridotomy, which was performed for prevention or treatment of angle closure glaucoma. The implanted graft was clearly confirmed in the anterior chamber using activated chandelier illumination. The graft was immediately attached to the host cornea, with eventual healing of BK in all eyes. No complication involving insertion or removal of the 25-gauge trocar and the chandelier illuminator was observed. No vision-threatening complication was observed in any of the 5 eyes. Conclusions: The chandelier illuminator provided good visibility of the anterior chamber and enhanced the safety of surgery by preventing formation of an inverted graft. PMID:28644235

  13. Descemet Membrane Endothelial Keratoplasty for Failed Deep Anterior Lamellar Keratoplasty: A Case Series.

    PubMed

    Einan-Lifshitz, Adi; Sorkin, Nir; Boutin, Tanguy; Mednick, Zale; Kreimei, Mohammad; Chan, Clara C; Rootman, David S

    2018-06-01

    To suggest a new surgical approach for posterior opacities or persistent Descemet membrane (DM) detachment in failed deep anterior lamellar keratoplasty (DALK) and to report the outcome of Descemet membrane endothelial keratoplasty (DMEK) in a series of patients with DALK failure. In this retrospective case series of patients who underwent DMEK for failed DALK at Toronto Western Hospital, 4 patients with failed DALK who underwent DMEK surgery were included. In all 4 cases, big bubble formation during initial DALK surgery had failed and the surgical technique was converted to manual dissection using the Melles technique. In 2 cases, the descemetorhexis in DMEK surgery was performed manually, and in 2 cases, the descemetorhexis was performed with the assistance of the femtosecond laser. Four eyes of 4 patients aged 70 ± 4 years were included. Average follow-up time was 9 ± 5 months. Indications for DALK surgery were corneal dystrophy in 2 patients and corneal scars in the other 2. DALK failure was due to persistent DM detachment that created a double chamber in 2 patients and due to posterior lamellar haze in the other 2. After DMEK surgery, 2 patients had graft detachment and required rebubbling. In 1 patient, the DMEK scroll was attached after 1 rebubble attempt, and in the other patient, a second rebubble attempt was needed. The final visual acuities were 20/40, 20/50, 20/70, and 20/200 (because of dense cataract). All procedures were uneventful. DMEK surgery may be effective in managing DALK failure.

  14. [Toric add-on intraocular lenses for correction of high astigmatism after pseudophakic keratoplasty].

    PubMed

    Hassenstein, A; Niemeck, F; Giannakakis, K; Klemm, M

    2017-06-01

    Perforating keratoplasty shows good morphological results with a clear cornea; however, a limiting factor is often the resulting astigmatism, which cannot be corrected with either glasses or contact lenses (CL) in up to 20% of the patients. We retrospectively investigated 15 patients after pseudophakic perforating keratoplasty, who received implantation of toric add-on intraocular lenses (IOL) to correct astigmatism. The mean preoperative astigmatism of 6.5 diopter (dpt) could be reduced to a mean postoperative value of 1.0 dpt. The mean visual acuity could be improved from a preoperative value of sc <0.05 (cc 0.6) to a postoperative value of sc 0.4 (cc 0.63). There were no complications except for one case of a lens extension tear. Based on our good experiences we now provide toric add-on IOL to all patients with pseudophakic perforating keratoplasty when this cannot be corrected or only insufficiently corrected by conservative methods.

  15. Infectious crystalline keratopathy caused by Cladosporium sp. after penetrating keratoplasty: a case report

    PubMed Central

    Stock, Ricardo Alexandre; Bonamigo, Elcio Luiz; Cadore, Emeline; Oechsler, Rafael Allan

    2016-01-01

    Background Infectious crystalline keratopathy is a rare, progressive infection characterized by the insidious progression of branches and crystalline corneal opacities with minimal or no inflammation. This case report describes the evolution of an infectious crystalline keratopathy caused by Cladosporium sp., which developed after tectonic keratoplasty in a patient with a history of ocular trauma. Case presentation A 40-year-old Brazilian male was the victim of firework-induced trauma to the left eye, which resulted in a corneal laceration that could not be sutured as well as a severe traumatic cataract. The patient underwent penetrating keratoplasty and phacoemulsification. During postoperative follow-up, another therapeutic keratoplasty was required because unresponsive infectious keratitis was observed. The infiltrate’s characteristics were suggestive of infectious crystalline keratopathy; in particular, the infiltrate was insidious and progressive, and grayish-white branches appeared in the anterior corneal stroma. As different therapies were administered, inflammatory reactions ranging from mild to severe were observed. The infection was unresponsive to typical antifungal drugs. This lack of response most likely occurred due to steroid treatment and the diffuse corneal spread of an atypical microorganism, which was subsequently identified in culture as Cladosporium sp. After the second therapeutic keratoplasty, the patient’s eye integrity was successfully reestablished. Conclusion This study likely provides the first report describing a case of infectious crystalline keratopathy caused by Cladosporium sp. This case emphasizes the clinical characteristics and outcome of this type of keratitis. PMID:27621671

  16. Potential use of lasers for penetrating keratoplasty.

    PubMed

    Thompson, K P; Barraquer, E; Parel, J M; Loertscher, H; Pflugfelder, S; Roussel, T; Holland, S; Hanna, K

    1989-07-01

    Experimental corneal trephination has been achieved with the 193 nm argon fluoride excimer and 2.9 microns hydrogen fluoride and Er:YAG laser systems. Compared with metal blades and other lasers, the 193 nm excimer laser creates the best quality corneal excision, but has a relatively slow etch rate through the stroma, and its use requires toxic gas. The mid-infrared laser systems trephine the cornea in less than 10 seconds, but cause a 10 microns to 15 microns zone of adjacent stromal damage and create wounds that are approximately 2.5 times larger than wounds made by metal scalpels. The wavelength and laser pulse duration influence the cutting characteristics of the laser. Optical delivery systems using an axicon lens, a rotating slit, and a computer controlled scanning optical system have been developed for penetrating keratoplasty. Selection of the optimal laser system for penetrating keratoplasty must await further experimental studies. Refinements of the laser cavity and delivery system are necessary before clinical studies can begin. A carefully controlled randomized clinical trial comparing laser trephination with conventional mechanical trephines will be necessary to determine the safety and efficacy of a laser trephination system.

  17. Two-photon optical microscopy imaging of endothelial keratoplasty grafts.

    PubMed

    Lombardo, Marco; Parekh, Mohit; Serrao, Sebastiano; Ruzza, Alessandro; Ferrari, Stefano; Lombardo, Giuseppe

    2017-03-01

    To investigate the microstructure of endothelial keratoplasty grafts using two-photon optical microscopy. Six endothelial keratoplasty grafts obtained from human donor corneoscleral tissues and prepared by submerged hydrodissection technique were imaged by two-photon optical microscopy. In each graft, two liquid bubbles were created in order to investigate the presence of a conserved cleavage plane regardless of the volume of posterior stroma that remained attached to Descemet's membrane (DM); the first bubble (bubble A) was generated under DM and the second bubble (bubble B) injection was done in order to obtain a layer of deep stroma that kept the two bubbles separated. Six human donor corneoscleral tissues were used as controls. Second harmonic generation and two-photon emitted fluorescence signals were collected from each specimen. Dissection of stroma occurred along the posterior collagen lamellae at variable distance from DM, which ranged between 3 and 16 μm in bubble A and between 23 and 41 μm in bubble B. The residual stroma included, anteriorly, bands of collagen lamellae, and thin bundles of stromal collagen fibrils, posteriorly, which were tightly intertwining with the underlying DM. There was no anatomically distinct plane of separation between these pre-Descemetic stromal collagen bundles and the overlying collagen lamellae with this hydrodissection technique. Two-photon optical microscopy provided label-free high-resolution imaging of endothelial keratoplasty grafts, showing that the most posterior stroma changes organization at approximately 10 μm above the DM. The pre-Descemetic stromal collagen fibrils form an intertwined complex with DM, which cannot be separated using hydrodissection.

  18. Preparation and Thickness Profile of Endothelial Keratoplasty Lenticules from Donated Whole Eyes with Previous Photorefractive Keratectomy

    PubMed Central

    Kanavi, Mozhgan Rezaei; Fahim, Pejman; Rahmanian, Mohsen; Chamani, Tahereh; Kheiri, Bahar; Balagholi, Sahar; Javadi, Mohammad Ali

    2017-01-01

    Purpose: To describe the preparation and thickness profiles of endothelial keratoplasty lenticules harvested from eyes with previous photorefractive keratectomy (PRK). Methods: Donor whole eyes that underwent PRK were subjected to microkeratome-assisted dissection for Descemet stripping automated endothelial keratoplasty. Specular microscopy and Visante optical coherence tomography were performed on precut corneas. Endothelial cell indices and thickness profiles of endothelial keratoplasty lenticules were statistically analyzed. Postoperative reports for transplanted lenticules were recorded. Results: Over a 6-month period, 2,929 whole eyes from 1,471 donors were screened for PRK. Twenty-five (0.85%) eyes from 14 donors were diagnosed with disciform haziness due to prior PRK and were used uneventfully for preparation of endothelial keratoplasty lenticules. Mean endothelial cell count was 3164.6 ± 311.0/mm2 and mean central posterior lenticule thickness was 128 ± 34 μm. Posterior lenticules revealed an increase in thickness from the central to peripheral cornea (mean increase of 26.2 μm at pericentral and 90.4 μm at peripheral locations). Mean increase in thickness was statistically different between two peripheral locations (74.5 μm vs. 108.1 μm, P = 0.047). Postoperative reports of transplanted lenticules revealed no posterior flap detachment or loss of clarity at least three months after the surgery. Conclusion: PRK donor whole eyes are potential sources for preparation of microkeratome-assisted thin endothelial keratoplasty lenticules with a high endothelial cell count. Although an asymmetric and significant increase in thickness was present at the peripheral cornea, neither attachment nor clarity of transplanted lenticules was affected by variations in thickness of precut corneas. PMID:29090046

  19. Collagen crosslinking for ectasia following PRK performed in excimer laser-assisted keratoplasty for keratoconus.

    PubMed

    Spadea, Leopoldo

    2012-01-01

    To report the results of corneal collagen crosslinking (CXL) in a patient with corneal ectasia developed after excimer laser-assisted lamellar keratoplasty for keratoconus and a secondary photorefractive keratectomy (PRK) for residual refractive error. A 33-year-old woman, who had originally been treated for keratoconus in the right eye by excimer laser-assisted lamellar keratoplasty, subsequently had her residual ametropia treated by topographically guided, transepithelial excimer laser PRK. Five years after PRK, the patient developed corneal ectasia showing concomitant visual changes of best spectacle-corrected visual acuity (BSCVA) reduced to 20/33 with a refraction of -6.00 +6.00 × 30. The minimum corneal thickness at the ectasia apex was 406 µm. A treatment of riboflavin-UVA-induced corneal CXL was performed on the right eye. Two years after the CXL treatment, the right eye improved to 20/20 BSCVA with a refraction of plano +1.00 × 50 while exhibiting a clear lamellar graft. Corneal CXL provided safe and effective management of ectasia developed after excimer laser-assisted lamellar keratoplasty and PRK.

  20. [Management of corneal endothelial decompensation with Descemet's membrane endothelial keratoplasty in a patient with Ahmed glaucoma valve implant].

    PubMed

    Röck, T; Bartz-Schmidt, K-U; Röck, D; Yoeruek, E

    2014-05-01

    Currently, the main causes for developing bullous keratopathy are from problems related to intraocular surgery, trauma, infection, Fuchs' endothelial dystrophy and chronically elevated intraocular pressure. In the 1990s penetrating keratoplasty was once considered the therapy of choice for treatment of bullous keratopathy but in recent years it has been replaced by posterior lamellar keratoplasty. The Descemet membrane endothelial keratoplasty (DMEK) procedure represents the final development of posterior lamellar keratoplasty. The question now arises whether DMEK can be used in patients with bullous keratopathy and Ahmed glaucoma valve implant. A 72-year-old man was referred to our hospital for further evaluation with the diagnosis of bullous keratopathy and pseudoexfoliative glaucoma. The bullous keratopathy was caused by a variety of previous operations as well as decompensation of intraocular pressure. This article describes the therapy of bullous keratopathy by DMEK with existing Ahmed glaucoma valve implant. After surgery the cornea became clear and the best-corrected visual acuity improved from hand movement to 0.2. The intraocular pressure remained normal (10-14 mmHg) without antiglaucoma medication and the endothelial cell count decreased only slightly over a follow-up of 13 months. No complications were encountered. The DMEK surgical procedure seems to be possible in patients with Ahmed glaucoma valve implant and endothelial decompensation. However, further studies with a larger number of patients should follow to validate the replacement of penetrating keratoplasty and other posterior lamellar procedures by DMEK.

  1. Cyclodiode photocoagulation for refractory glaucoma after penetrating keratoplasty.

    PubMed

    Shah, P; Lee, G A; Kirwan, J K; Bunce, C; Bloom, P A; Ficker, L A; Khaw, P T

    2001-11-01

    This study analyzes the results of intraocular pressure (IOP) reduction by contact diode cycloablation (cyclodiode) in cases of refractory glaucoma after penetrating keratoplasty. Retrospective noncomparative, interventional case series. Twenty-eight eyes in 28 patients attending the Moorfields Eye Hospital. Cyclodiode (40 applications x 1.5 W x 1.5 seconds over 270-300 degrees ) was used to control the IOP in refractory glaucoma after penetrating keratoplasty. Postoperative IOP, graft status, visual acuity, and number of antiglaucoma medications were recorded after cyclodiode treatment. Cyclodiode resulted in a reduction of IOP from a median of 33 mmHg (interquartile range [28, 40.5]) to a median of 15 mmHg (interquartile range [12, 20.5]). Most patients had a significant lowering in IOP with a median reduction of 16 mmHg (interquartile range [12, 25]; P < 0.0001). IOPs of 6 to 21 mmHg were achieved in 22 patients (79%). Sixteen patients (57%) required more than one treatment with cyclodiode to control the IOP, with three patients (11%) requiring three treatments and two patients (7%) requiring four treatments. Visual acuity improved (> two Snellen lines of acuity) in three patients (11%) and remained the same (+/- one Snellen line) in 17 patients (61%). The mean number of antiglaucoma medications before cycloablation was 2.6 and was 1.8 after treatment (P < 0.001). Of the 19 patients (68%) with originally clear grafts, three grafts (16%) developed opacification. One patient (4%), with a history of nanophthalmos and recurrent uveal effusion, had delayed hypotony (IOP < 6 mmHg) occurring 46 months after the diode treatment. All patients had at least 6 months follow-up. These patients have often undergone multiple previous complicated ocular interventions and are often not suitable for filtration surgery. Reduction of IOP with maintenance of visual acuity and a good safety profile was achieved in most patients in this study but may require multiple treatments. We

  2. Fitting the post-keratoplasty cornea with hydrogel lenses.

    PubMed

    Katsoulos, Costas; Nick, Vasileiou; Lefteris, Karageorgiadis; Theodore, Mousafeiropoulos

    2009-02-01

    We report two cases who have undergone penetrating keratoplasty (three eyes total), and who were fitted with hydrogel lenses. In the first case, a 28-year-old male presented with an interest in contact lens fitting. He had undergone corneal transplantation in both eyes, about 5 years ago. After topographies and trial fitting were performed, it was decided to be fitted with reverse geometry hydrogel lenses, due to the globular geometry of the cornea, the resultant instability of RGPs, and personal preference. In the second case, a 26-year-old female who had also penetrating keratoplasty was fitted with a hydrogel toric lens of high cylinder in the right eye. The final hydrogel lenses for the first subject incorporated a custom tricurve design, in which the second curve was steeper than the base curve and the third curve flatter than the second but still steeper than the first. Visual acuity was 6/7.5 RE and a mediocre 6/15 LE (OU 6/7.5). The second subject achieved 6/4.5 acuity RE with the high cylinder hydrogel toric lens. In corneas exhibiting extreme protrusion, such as keratoglobus and some cases after penetrating keratoplasty, curvatures are so extreme and the cornea so globular leading to specific fitting options: sclerals, small diameter RGPs and reverse geometry hydrogel lenses, in order to improve lens and optical stability. In selected cases such as the above, large diameter inverse geometry RGP may be fitted only if the eyelid shape and tension permits so. The first case demonstrates that the option of hydrogel lenses is viable when the patient has no interest in RGPs and in certain cases can improve vision to satisfactory levels. In other cases, graft toricity might be so high that the practitioner will need to employ hydrogel torics with large amounts of cylinder in order to correct vision. In such cases, the patient should be closely monitored in order to avoid complications from hypoxia.

  3. Indications and outcomes of pediatric keratoplasty in a tertiary eye care center: A retrospective review.

    PubMed

    Gulias-Cañizo, Rosario; Gonzalez-Salinas, Roberto; Hernandez-Zimbron, Luis Fernando; Hernandez-Quintela, Everardo; Sanchez-Huerta, Valeria

    2017-11-01

    To evaluate indications and outcomes of pediatric keratoplasty in a tertiary eye center, and identify factors that affect visual outcomes.We performed a retrospective review of penetrating keratoplasty in children aged 0 to 18 years between 1995 and 2011 in the Asociación para Evitar la Ceguera en México IAP, Hospital "Dr. Luis Sánchez Bulnes".A total of 574 penetrating keratoplasties were performed during the study interval. Median follow-up was 5.0 years. Main indications included keratoconus (55.58%), postherpetic scarring (9.58%), traumatic opacities (7.49%), and bullous keratopathy (6.09%). Rejection rates at 5 years were 27% overall, and among indications, keratoconus showed the best graft survival at 60-months follow-up (85%). The percentage of patients with best corrected visual acuity (BCVA) posttransplant >20/400 at 5 years in the nonrejection group was 81.25% and 82.74% in < and > 10 years of age (YOA) groups, respectively, versus a BCVA posttransplant > 20/400 at 5 years in the rejection group of 53.68% and 51.72% in < and > 10 YOA groups, respectively. There was a statistically significant reduced rejection rate between genders at 18 months of follow-up, favoring males.Despite being considered a high-risk procedure in children, penetrating keratoplasty can achieve good results, especially in patients with keratoconus. It can achieve significative improvements of visual acuity, provided there is an adequate follow-up and treatment adherence.

  4. [Astigmatism after keratoplasty: influence of orthotopic transplantation].

    PubMed

    Feuerstacke, J; Hellwinkel, O; Naydis, I; Linke, S; Klemm, M

    2014-09-01

    Patients undergoing corneal transplantation often suffer from postoperative reduced vision due to high astigmatism. This retrospective study analyzed the influence of heterotopic or orthotopic transplantation on astigmatism and visual outcome. In this study 373 eyes of 334 patients were analyzed. Group 1 (OT) contained 186 eyes, which underwent orthotopic transplantation (side of recipient and donor corresponded), whereas group 2 (HT) included 187 heterotopic keratoplasties (donor cornea placed in the recipient's contralateral side). After 1, 3, 6, 12 and 24 months the median of keratometric astigmatism, objective astigmatism, topographic astigmatism and best corrected visual acuity (BCVA) were assessed and compared between groups. The long-term results showed no statistically significant differences regarding keratometric and objective astigmatism, whereas topographic astigmatism differed significantly (p = 0.04) after 3 months. We observed a lower astigmatism of 5.7 dpt (range 3.08-7.78 dpt) in group OT than in the group HT with 7.1 dpt (range 3.9-10.7 dpt). No differences were found at the other time points. The BCVA showed a significantly better effect after 1 month (p = 0.01) in the OT group of 0.2 (0.1-0.3) than in HT group of 0.1 (0.05/0.25). In the postoperative course no additional significant dissimilarities were documented. Heterotopic and orthotopic keratoplasty show no significant long-term differences in astigmatism and visual outcom.

  5. Microkeratome-Assisted Anterior Lamellar Keratoplasty for the Correction of High-Degree Postkeratoplasty Astigmatism.

    PubMed

    Gutfreund, Shay; Leon, Pia; Busin, Massimo

    2017-07-01

    To describe the surgical technique and report the outcomes of patients treated with microkeratome-assisted anterior lamellar keratoplasty (MALK) for the correction of high-degree postkeratoplasty astigmatism. Four eyes of 2 patients with extremely high (>10 D) and irregular [surface asymmetry index >1.0 D] post-penetrating keratoplasty astigmatism occurring after complete suture removal underwent MALK and were followed for at least 3 years after the procedure. In all cases, 250-µm lamellar keratectomy was performed, followed by 2 full-thickness incisions through the penetrating keratoplasty scar and the placement of an appropriately sized donor graft, which was secured with a double-running 10-0 nylon suture. All sutures were removed in all eyes within 1 year from surgery. Corrected distance visual acuity, refraction, corneal topography, and endothelial cell density were noted at each examination. At the last follow-up examination (3 years or longer after MALK), corrected distance visual acuity had improved to 20/20, refractive astigmatism had decreased to an average of 2.1 D (in all cases within 4.5 D), and the average surface asymmetry index had reduced from 2.27 to 0.56. MALK is an effective and safe technique for the correction of high-degree postkeratoplasty astigmatism.

  6. Descemet membrane endothelial keratoplasty (DMEK) early stage graft failure in eyes with preexisting glaucoma.

    PubMed

    Treder, Maximilian; Alnawaiseh, Maged; Eter, Nicole

    2017-07-01

    To evaluate the effect of a preexisting glaucoma on the early postoperative outcome of a descemet membrane endothelial keratoplasty (DMEK). All patients who underwent DMEK surgery at the Department of Ophthalmology of the University of Muenster with a follow-up of at least 3 months (90d) were included in this study. The best corrected distance visual acuity (BCDVA), the intraocular pressure (IOD), the rate of re-keratoplasty and the rebubbling rate were inter alia recorded. The results of patients with (group 1) and without a preexisting glaucoma (group 2) were compared. 74 eyes of 59 patients with a mean follow-up of 152 ± 70 days were included. 65 eyes were in group 1 and 9 eyes in group 2. The BCDVA significantly improved in both groups after surgery (p < 0.03). The Re-keratoplasty rate (p = 0.172), the number of rebubblings per patient (p = 0.571) and the rebubbling rate (p = 0.939) were not significantly different in patients without glaucoma compared to patients with a preexisting glaucoma. In the early stage outcome of DMEK no significant impact of a preexisting glaucoma was found.

  7. Combined keratoplasty, cataract extraction, and intraocular lens implantation after corneolenticular laceration in children.

    PubMed

    Vajpayee, R B; Angra, S K; Honavar, S G

    1994-04-15

    Over a period of two years we performed combined penetrating keratoplasty, cataract extraction, and intraocular lens implantation in seven children between the ages of 2 and 12 years old. The interval between trauma and the surgery varied from six weeks to six months (3.5 +/- 1.6 months, mean +/- SD). All of the patients had undergone primary repair of corneal perforation. Fresh corneas preserved in McCarey-Kaufman medium were used. The graft size was 7.5 mm with 0.5 mm disparity. Posterior chamber polymethylmethacrylate C-loop lenses were used in all cases. The surgeon's average postkeratoplasty keratometry was used in the calculation of intraocular lens power. The follow-up period ranged from nine to 36 months (18 +/- 9.1 months, mean +/- SD). Six grafts remained clear at the final follow-up. The visual acuity ranged from 20/40 to 20/200 with final astigmatism ranging from 0.5 diopter to 2.0 diopters. One patient developed a retinal detachment 12 months after surgery, which was successfully reattached. One patient, who had preoperative corneal vascularization, had graft rejection, which was treated medically. Our limited series suggests that the triple ocular procedure is a good choice for the treatment of corneolenticular trauma in children. The proper postoperative treatment includes vigorous antiamblyopia therapy and Nd:YAG laser treatment of after-cataracts.

  8. Air Bubble-Induced High Intraocular Pressure After Descemet Membrane Endothelial Keratoplasty.

    PubMed

    Röck, Daniel; Bartz-Schmidt, Karl Ulrich; Röck, Tobias; Yoeruek, Efdal

    2016-08-01

    To investigate the incidence and risk factors of pupillary block caused by an air bubble in the anterior chamber in the early postoperative period after Descemet membrane endothelial keratoplasty (DMEK). A retrospective review was conducted in 306 eyes that underwent DMEK from September 2009 through October 2014 at the Tübingen Eye Hospital. Intraocular pressure (IOP) elevation was defined as a spike above 30 mm Hg. In the first 190 eyes, an intraoperative peripheral iridectomy was performed at the 12-o'clock position and in the other 116 eyes at the 6-o'clock position. If possible, reasons for IOP elevation were identified. For all eyes, preoperative and postoperative slit-lamp examinations and IOP measurements were performed. Overall, 30 eyes (9.8%) showed a postoperative IOP elevation within the first postoperative day. The incidence of IOP elevation was 13.9% (5/36) in the triple DMEK group, and 2 of 5 phakic eyes (40%) developed an air bubble-induced IOP elevation. All eyes presented with a de novo IOP elevation, associated in 25 patients with pupillary block from air anterior to iris and in 5 patients with angle closure from air migration posterior to the iris. All of them had an iridectomy at the 12-o'clock position. A postoperative pupillary block with IOP elevation caused by the residual intraoperative air bubble may be an important complication that could be avoided by close and frequent observations, especially in the first postoperative hours and by an inferior peripheral iridectomy and an air bubble with a volume of ≤80% of the anterior chamber.

  9. Association Between Fungal Contamination and Eye Bank-Prepared Endothelial Keratoplasty Tissue: Temperature-Dependent Risk Factors and Antifungal Supplementation of Optisol-Gentamicin and Streptomycin.

    PubMed

    Brothers, Kimberly M; Shanks, Robert M Q; Hurlbert, Susan; Kowalski, Regis P; Tu, Elmer Y

    2017-11-01

    Fungal contamination and infection from donor tissues processed for endothelial keratoplasty is a growing concern, prompting analysis of donor tissues after processing. To determine whether eyebank-processed endothelial keratoplasty tissue is at higher risk of contamination than unprocessed tissue and to model eyebank processing with regard to room temperature exposure on Candida growth in optisol-gentamicin and streptomycin (GS) with and without antifungal supplementation. An examination of the 2013 Eversight Eyebank Study follow-up database for risk factors associated with post-keratoplasty infection identified an increased risk of positive fungal rim culture results in tissue processed for endothelial keratoplasty vs unprocessed tissue. Processing steps at room temperature were hypothesized as a potential risk factor for promotion of fungal growth between these 2 processes. Candida albicans, Candida glabrata, and Candida parapsilosis endophthalmitis isolates were each inoculated into optisol-GS and subjected to 2 different room temperature incubation regimens reflective of current corneal tissue handling protocols. Eversight Eyebank Study outcomes and measures were follow-up inquiries from 6592 corneal transplants. Efficacy study outcomes and measures were fungal colony-forming units from inoculated vials of optisol-GS taken at 2 different processing temperatures. Donor rim culture results were 3 times more likely to be positive for fungi in endothelial keratoplasty-processed eyes (1.14%) than for other uses (0.37%) (difference, 0.77%; 95% CI, 0.17-.1.37) (P = .009). In vitro, increased room temperature incubation of optisol-GS increased growth of Candida species over time. The addition of caspofungin and voriconazole decreased growth of Candida in a species-dependent manner. Detectable Candida growth in donor rim cultures, associated with a higher rate of post keratoplasty infection, is seen in endothelial keratoplasty tissue vs other uses at the time of

  10. Comparison of graft survival following penetrating keratoplasty and Descemet's stripping endothelial keratoplasty in eyes with a glaucoma drainage device.

    PubMed

    Iverson, Shawn M; Spierer, Oriel; Papachristou, George C; Feuer, William J; Shi, Wei; Greenfield, David S; O'Brien, Terrence P

    2018-02-01

    To compare corneal graft survival rates after penetrating keratoplasty (PK) and Descemet's stripping endothelial keratoplasty (DSEK) in patients with a glaucoma drainage device (GDD) or medically managed glaucoma. A retrospective chart review was conducted on consecutive patients who underwent primary PK or primary DSEK. Inclusion criteria consisted of eyes with a diagnosis of glaucoma prior to corneal transplantation and a minimum of 6 months of follow-up. Graft failure was defined as an edematous cornea with failure to maintain deturgescence lasting beyond a period of 1 month of intense steroid therapy or vascularization and scarring resulting in irreversible loss of central graft clarity. Corneal graft survival was calculated using Kaplan-Meier survival analysis. Patients were divided into four groups: GDD-PK, GDD-DSEK, medical-PK and medical-DSEK. Fifty-six eyes of 56 patients were identified as meeting inclusion criteria. Among eyes with a GDD, there was no difference in the proportion of failures between PK grafts (48%) and DSEK grafts (50%) (p = 0.90). Failure occurred earlier in DSEK recipients compared to PK recipients, 5.82 ± 6.77 months versus 14.40 ± 7.70 months, respectively (p = 0.04). A Kaplan-Meier analysis did not identify a difference between the four groups with respect to graft failure (p = 0.52). There is no significant difference in graft survival rates between medically and surgically treated glaucoma patients for either PK or DSEK grafts. In patients with GDD, graft failure occurs earlier in DSEK compared to PK.

  11. New stroboscopic light source and technique for intraoperative retinal fluorescein angiography during penetrating keratoplasty

    NASA Astrophysics Data System (ADS)

    Krueger, Ronald R.; Morales, Ronald B.; Chong, Lawrence P.; Smith, Ronald E.

    1994-06-01

    We report the development of a new stroboscopic light source system and technique for performing intraoperative fluorescein angiography during penetrating keratoplasty for aphakic or pseudophakic bullous keratopathy. A controllable pulse xenon light source system with a fiber optic endoilluminator probe is used to perform high-quality intraoperative fluorescein angiography during penetrating keratoplasty in pigmented rabbits and human subjects. Following corneal trephination and extraction of the intraocular lens, a temporary Cobo keratoprosthesis is secured while a 20-gauge endoilluminator is inserted into the vitreous cavity through a limbal incision. The endoilluminator is advanced to a retinal illumination area of approximately 3 DD and 10% fluorescein is injected intravenously. A microscope camera coupled to a 50:50 beamsplitter photographs the passage of fluorescein dye while the surgeon maintains an unaltered view through the operating microscope. Angiograms through a keratoprosthesis show excellent contrast and resolution, comparable to standard fluorescein angiography. Fine peripapillary vessels are seen reproducibly and with great detail in the rabbits. All the phases of retinal angiography can be seen, including arteriolar constriction and capillary nonperfusion in one of four human subjects examined. High quality intraoperative fluorescein angiography can be performed in patients undergoing penetrating keratoplasty for aphakic/ pseudophakic bullous keratopathy. With this technology, preexisting retinal disorders such as cystoid macular edema might be identified in the perioperative setting allowing for important management decisions to be made intraoperatively.

  12. [Endothelial keratoplasty: Descemet stripping (DSEK) using TAN EndoGlide™ device: case series].

    PubMed

    Pazos, Henrique Santiago Baltar; Pazos, Paula Fernanda Morais Ramalho Baltar; Nogueira Filho, Pedro Antônio; Grisolia, Ana Beatriz Diniz; Silva, André Berger Emiliano; Gomes, José Álvaro Pereira

    2011-01-01

    To report the results of Descemet stripping endothelial keratoplasty (DSEK) using the TAN EndoGlideTM device to facilitate the insertion of the endothelial membrane. Prospective clinical study that included nine patients presenting corneal edema secondary to endothelial dysfunction. Best corrected visual acuity, refraction, central corneal thickness, endothelial cell density and complications were analyzed after a six-month follow-up. There was a significant improvement in the corneal edema and visual acuity in 7 patients (77.78%). The best corrected visual acuity ranged between 20/40 and 20/200. The average density of endothelial cells in six months varied between 1,305 cells/mm² and 2,346 cells/mm² with an average loss of 33.14% cells. Detachment of part of the graft was observed in one eye (11.11%) and primary failure of the endothelial transplantation occurred in 2 eyes (22.22%). The device TAN EndoGlideTM facilitates the introduction of the graft in Descemet stripping endothelial keratoplasty.

  13. Outcomes of Descemet Stripping Endothelial Keratoplasty Using Eye Bank-Prepared Preloaded Grafts.

    PubMed

    Palioura, Sotiria; Colby, Kathryn

    2017-01-01

    To evaluate the feasibility of Descemet stripping endothelial keratoplasty using grafts preloaded by an eye bank in a commercially available insertion device. In this retrospective case series, a series of 35 eyes in 34 consecutive patients who underwent Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy or previously failed full-thickness grafts at a single tertiary care center from March 2013 to March 2014 was included. The donor tissue had undergone pre-lamellar dissection, trephination, and loading into EndoGlide Ultrathin inserters at the Lions Eye Institute for Transplant and Research (Tampa, FL) and was shipped overnight in Optisol GS to the surgeon (K.C.). Surgery was performed within 24 hours from tissue preparation and loading by the eye bank. Donor and recipient characteristics, endothelial cell density (ECD), best-corrected visual acuity, and central corneal thickness were recorded. The main outcome measures were intraoperative and postoperative complications and ECD loss at 3, 6, and 12 months. One primary graft failure (2.8%), 2 rebubblings (5.7%), and 1 graft rejection (2.8%) occurred. Mean preoperative donor ECD was 2821 ± 199 cells/mm. Six months postoperatively, the mean endothelial cell loss was 25.3% ± 17.2% (n = 32), which remained stable at 1 year (31.5% ± 17.9%, n = 32). Mean best-corrected visual acuity improved from 20/100 preoperatively to 20/25 at a mean follow-up of 1 year (n = 32). Mean central corneal thickness was reduced from 711 ± 110 μm to 638 ± 66 μm at the last follow-up visit. Donor graft tissue preloaded by an eye bank can be used successfully for endothelial keratoplasty. Preloading reduces intraoperative tissue manipulation.

  14. Incidence and Outcomes of Positive Donor Corneoscleral Rim Fungal Cultures after Keratoplasty.

    PubMed

    Vislisel, Jesse M; Goins, Kenneth M; Wagoner, Michael D; Schmidt, Gregory A; Aldrich, Benjamin T; Skeie, Jessica M; Reed, Cynthia R; Zimmerman, M Bridget; Greiner, Mark A

    2017-01-01

    To determine the incidence of positive corneoscleral donor rim fungal cultures after keratoplasty and to report clinical outcomes of grafts with culture-positive donor rims. Retrospective cohort study. Consecutive donor corneas and keratoplasty recipients at a single tertiary referral center over 20 years. Patient charts were reviewed to determine the incidence of positive donor rim fungal cultures and clinical outcomes of all grafts using contaminated tissue. The primary outcome measures were positive donor rim fungal culture results and the development of postkeratoplasty fungal infection using corresponding corneal tissue. The secondary outcome measure was the impact of postoperative prophylaxis on donor tissue-associated infections. A total of 3414 keratoplasty cases were included in the statistical analysis. Seventy-one cases (2.1%) were associated with a fungal culture-positive donor rim. Candida species were cultured in 40 cases (56.3%). There was a higher incidence of positive rim cultures over the last 5 years of the analytic period compared with the first 15 years (P = 0.018). Fungal keratitis developed in 4 cases (5.6%), and all patients required further surgical intervention to achieve cure. There were no cases of fungal endophthalmitis. Empiric antimycotic prophylaxis initiated at the time of positive culture result reduced the incidence of keratitis from 15.8% in untreated cases to 1.9% in treated cases (P = 0.056). Positive donor rim fungal cultures are uncommon, but carry an unacceptably high risk of postoperative fungal infection. This risk may be reduced with prophylactic antimycotic therapy when culture-positive donor rims are identified. Copyright © 2016 American Academy of Ophthalmology. All rights reserved.

  15. Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism

    PubMed Central

    Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S

    2013-01-01

    Aims In a previous study, we proposed that corneal topography performed 30–40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. Methods 10/0 nylon interrupted sutures were placed, to secure the graft–host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30–40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4–6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Results Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). Conclusion SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty. PMID:23743526

  16. Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism.

    PubMed

    Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S

    2013-09-01

    In a previous study, we proposed that corneal topography performed 30-40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. 10/0 nylon interrupted sutures were placed, to secure the graft-host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30-40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4-6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty.

  17. Intraocular pressure measurements after conductive keratoplasty.

    PubMed

    Kymionis, George D; Naoumidi, Tatiana L; Aslanides, Ioannis M; Kumar, Vinod; Astyrakakis, Nikolaos I; Tsilimbaris, Miltiadis; Pallikaris, Ioannis G

    2005-01-01

    To determine the possible impact of conductive keratoplasty (CK) on intraocular pressure (IOP) measurements. A prospective, single-center, noncomparative interventional case series was performed. Baseline and postoperative IOPs were measured by Goldmann applanation tonometry in 32 eyes of 18 patients who underwent CK for hyperopia correction. Mean follow-up was 11.9 months (range: 8 to 18 months). After CK, a statistically significant decrease in the measured IOP was observed (before CK: 14.22+/-1.64 vs after CK: 12.66+/-2.21, P<.001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or attempted correction. Despite the limitations due to the small number of patients enrolled in this study, the applanation tonometer appears to underestimate the true IOP after CK.

  18. Corneal Astigmatism Stability in Descemet Membrane Endothelial Keratoplasty for Fuchs Corneal Dystrophy.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2016-07-01

    To calculate the magnitude and angle of the shift in corneal astigmatism associated with Descemet membrane endothelial keratoplasty (DMEK) surgery to determine the feasibility of concurrent astigmatism correction at the time of DMEK triple procedures. Retrospective study. Forty-seven eyes that previously underwent the DMEK procedure for Fuchs endothelial corneal dystrophy and that had more than 1.0 diopter (D) of front corneal astigmatism preoperatively were identified. All DMEK surgeries used a clear corneal temporal incision of 3.2 mm. Surgically induced astigmatism (SIA) was evaluated 6 months postsurgery with vector analysis using Scheimpflug image reading. We did not find a difference between pre- and postoperative magnitude of front astigmatism (P = 0.88; paired t test). The magnitude of the SIA front surface was 0.77 ± 0.63 D (range, 0.10-3.14 D). The centroid vector of the SIA front surface was 0.14 at 89.3°. A hyperopic corneal power shift was noted in both the front surface by 0.26 ± 0.74 D (range, 0.45-3.05 D) (P = 0.018; paired t test) and back surface by 0.56 ± 0.55 D (range, 0.25-2.40 D) (P < 0.01; paired t test). DMEK surgery induces minimal amounts of corneal astigmatism that is a with-the-rule shift associated with a temporal clear corneal incision. The stability of these data from preop to postop supports the plausibility of incorporating astigmatism correction with the cautious use of toric intraocular lenses for patients with Fuchs corneal dystrophy and cataract.

  19. Intraocular Lens Opacification After Endothelial Keratoplasty as Analyzed by Environmental Scanning Electron Microscopy.

    PubMed

    Verdaguer, Paula; Gris, Oscar; Casaroli-Marano, Ricardo P; Elies, Daniel; Muñoz-Gutierrez, Gerardo; Güell, Jose L

    2015-08-01

    To describe a case of hydrophilic intraocular lens (IOL) opacification based on IOL analysis after Descemet stripping automated endothelial keratoplasty. A 60-year-old woman had uneventful phacoemulsification after the implantation of a hydrophilic IOL (Akreos-Adapt; Bausch & Lomb) into both eyes. Because of postoperative corneal decompensation in the right eye, 2 Descemet stripping automated endothelial keratoplasty operations were performed within 1 year. After the second procedure, the graft was not well attached, requiring an intracameral injection of air on day 3. After 1 year, opacification was observed on the superior 2/3 of the anterior surface of the IOL, along with a significant decrease in visual acuity. The IOL was explanted 6 months after the opacification. Environmental scanning electron microscopy followed by x-ray microanalysis revealed an organic biofilm on the surface of the IOL. To our knowledge, this is the first reported case in which the material deposited on the lens is organic rather than calcific.

  20. Stepwise Guided Photorefractive Keratectomy in Treatment of Irregular Astigmatism After Penetrating Keratoplasty and Deep Anterior Lamellar Keratoplasty.

    PubMed

    Sorkin, Nir; Einan-Lifshitz, Adi; Abelson, Sagi; Boutin, Tanguy; Showail, Mahmood; Borovik, Armand; Ashkenazy, Zach; Chan, Clara C; Rootman, David S

    2017-11-01

    To report the outcome of stepwise ablation using topography-guided photorefractive keratectomy to treat irregular astigmatism after either penetrating keratoplasty (PKP) or deep anterior lamellar keratoplasty (DALK). This is a retrospective, interventional analysis including patients with irregular astigmatism after either PKP or DALK, who underwent topography-guided photorefractive keratectomy. The entire cohort was analyzed, as well as the PKP and DALK groups separately. Analysis of factors associated with a better outcome was also performed. Thirty-four eyes of 34 patients (20 PKP patients and 14 DALK patients) aged 47.4 ± 15.9 years were included. Twenty-one patients underwent more than 1 ablation. Refractive stability and a minimal period of 5 months were required before repeat ablation. The average follow-up duration was 17.0 ± 6.0 months. Corrected distance visual acuity (CDVA) improved significantly from 0.22 ± 0.14 logarithm of the minimum angle of resolution (logMAR) to 0.14 ± 0.12 logMAR at final follow-up (P = 0.035). Uncorrected distance visual acuity (UDVA) improved significantly from 0.90 ± 0.54 logMAR to 0.57 ± 0.40 logMAR at final follow-up (P = 0.004). CDVA and UDVA improved by ≥1 Snellen lines in 54.2% and 70.8% of the eyes, respectively, and by ≥3 Snellen lines in 16.7% and 54.2% of the eyes, respectively. Statistically significant improvement was seen in optical aberrometry indices (total root mean square, higher-order aberration root mean square, defocus, coma, trefoil, and spherical aberration). The difference between PKP and DALK in either CDVA (P = 0.562) or UDVA (P = 0.384) improvement was nonsignificant. The stepwise topography-guided photorefractive keratectomy approach in cases of irregular astigmatism after PKP or DALK can help improve visual acuity outcomes. Patients should be appropriately counseled that more than 1 treatment will likely be needed.

  1. Changing Practice Patterns and Long-term Outcomes of Endothelial Versus Penetrating Keratoplasty: A Prospective Dutch Registry Study.

    PubMed

    Dickman, Mor M; Peeters, Jean Marie P W U; van den Biggelaar, Frank J H M; Ambergen, Ton A W; van Dongen, Martin C J M; Kruit, Pieter Jan; Nuijts, Rudy M M A

    2016-10-01

    To compare graft survival, best-corrected visual acuity (BCVA), endothelial cell density (ECD), and refraction following penetrating keratoplasty (PK) vs endothelial keratoplasty (EK) for Fuchs endothelial dystrophy (FED) and pseudophakic bullous keratopathy (PBK). Nonrandomized treatment comparison with national registry data. All consecutive patients undergoing first keratoplasty for FED and PBK between 1998 and 2014 were analyzed, with a maximum follow-up of 5 years (mean ± SD follow-up 39 ± 20 months, range 0-60 months). Graft survival was analyzed using Kaplan-Meier survival curves and Cox regression analysis. BCVA, ECD, and refractive error were compared using linear mixed models. Main outcome measures were graft survival, BCVA, refraction, and ECD. A total of 5115 keratoplasties (PK = 2390; EK = 2725) were identified. Two-year graft survival following EK was lower compared with PK (94.5% vs 96.3%, HR = 1.56, P = .001). Five-year survival was comparable for EK and PK (93.4% vs 89.7%, HR = 0.89, P = .261). EK graft survival improved significantly over time while remaining stable for PK. One-year BCVA was better following EK vs PK (0.34 vs 0.47 logMAR, P < .001). Astigmatism was lower 1 year after EK vs PK (-1.69 vs -3.52 D, P < .001). One-year ECD was lower after EK vs PK (1472 vs 1859 cells/mm 2 , P < .001). At 3 years, ECD did not differ between EK and PK. Long-term graft survival after EK and PK is high and comparable despite lower short-term survival for EK. EK graft survival improved over time, suggesting a learning curve. EK results in better BCVA, lower astigmatism, and similar long-term ECD compared with PK for FED and PBK. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Indications for and outcomes of repeat penetrating keratoplasty, 1989-1995.

    PubMed

    Patel, N P; Kim, T; Rapuano, C J; Cohen, E J; Laibson, P R

    2000-04-01

    To evaluate the indications for and outcomes of repeat penetrating keratoplasty over a 7-year period and compare them to a similar study over the prior 6-year period at the same institution. Retrospective noncomparative case series. Two hundred twenty-three consecutive repeat corneal transplants performed by one of five corneal surgeons between 1989 and 1995 were studied. Reasons for primary and regraft failure, indications for the initial corneal graft, graft clarity, and best-corrected visual acuity were measured on each patient. Between 1989 and 1995, 16% (271 of 1689) of transplants performed by our cornea group were regrafts compared with 9% (165 of 1860) in the period from 1983 to 1988 (P < 0.01). The most common indications for penetrating keratoplasty before regraft were pseudophakic bullous keratopathy (27%, 61 of 223), failed graft (20%, 44 of 223), Fuchs' dystrophy (11%, 24 of 223), aphakic bullous keratopathy (9%, 21 of 223), keratoconus (8%, 17 of 223), and herpes simplex keratitis (6%, 14 of 223). Compared with the prior study period of 1983 to 1988, an increase was revealed in the incidence of failed graft (11% to 20%, P = 0.03), and a decrease was revealed in the incidence of aphakic bullous keratopathy (19% to 9%, P = 0.01). Of the 223 regrafts, 55 (25%) failed during the study period (range, 1 month to 7.5 years; mean 2.1 years). Eleven percent (6 of 55) of regraft failures occurred within 6 months, and 55% (30 of 55) failed within 18 months. Of the 150 regrafts with 2 years follow-up (mean, 3.9 years), 111 (74%) had clear grafts. A best-corrected visual acuity of 20/20 to 20/40 was achieved in 41% (46 of 111), 20/50 to 20/100 in 32% (36 of 111), 20/200 to 20/400 in 21% (23 of 111), and counting fingers to no light perception in 5% (6 of 111). Failed grafts are increasing as an indication for penetrating keratoplasty. Graft clarity and visual acuity results continue to be very good, supporting the use of repeat corneal transplantation.

  3. Frequency of Complications During Preparation of Corneal Lamellae Used in Posterior Lamellar Keratoplasty Using the Pneumodissection Technique (Big Bubble).

    PubMed

    Studeny, Pavel; Netukova, Magdalena; Hlozanek, Martin; Bednar, Jan; Jirsova, Katerina; Krizova, Deli

    2018-04-26

    To determine the frequency of formation of various types of bubbles and the potential impact of donor and lamella parameters on this frequency, and to identify possible risk factors of unsuccessful "big-bubble" creation in preparation of pre-Descemet endothelial keratoplasty and Descemet membrane endothelial keratoplasty with peripheral stromal support. Donor age and sex, death to preservation time (DPT), storage time, presence of corneal scars (mainly a condition after cataract surgery), and endothelial cell density of 256 donor corneas were assessed before Descemet membrane endothelial keratoplasty with peripheral stromal support or pre-Descemet endothelial keratoplasty lamella preparation using the big-bubble technique. Mean donor age was 62.3 ± 8.5 years (28.3% women and 71.7% men). Mean endothelial cell density of the donor graft was 2866 ± 255 cells/mm. Mean DPT was 10.12 ± 4.88 hours, and mean storage time of the transplant before surgery was 6.5 ± 4.8 days. Corneal scars were present in 17 donor grafts (6.6%) after cataract surgery. Eleven corneas were devalued because of Descemet membrane rupture during preparation (4.3%). In 182 corneas, standard bubble type I was created (71.7%); in 27 corneas, bubble type II was created; eventually, both types of bubbles formed simultaneously (10.5%); in 47 corneas, no bubble was created (18.4%). We identified higher endothelial cell density, shorter DPT, and the presence of corneal scars after cataract surgery as risk factors threatening successful bubble formation. The only risk factor for creating type II bubbles was higher donor age in our study.

  4. Cross-Linking as an Adjuvant Treatment for Tectonic Corneal Lamellar Graft Preparation

    PubMed Central

    Kymionis, George D.; Plaka, Argyro D.; Diakonis, Vasilios F.; Grentzelos, Michael A.; Kontadakis, Georgios A.; Mersinoglou, Andreana C.; Detorakis, Efstathios T.; Topouzis, Fotis

    2013-01-01

    Purpose: To describe a new surgical approach for the tectonic reconstruction of the anterior ocular segment and the management of scleral and conjuctival melting. Methods: Case series of patients demonstrating anterior segment anomalies, such as scleral and conjunctival melting. The anterior stromal part of a pre-cut corneal graft for Descemet’s stripping automated endothelial keratoplasty (DSAEK) was cross-linked with riboflavin and ultraviolet A irradiation and was used to cover scleral (scleral melting in a patient with necrotizing scleritis, one case) and conjuctival (dehiscence of the conjunctiva in patients with anti-glaucomatous valve exposure, two cases) areas. The endothelial part of all corneal grafts was used for DSAEK in patients with need of corneal endothelial transplantation. Results: Repair of scleral and conjuctival melting was successful in all cases. No intra- or post- operative complications occured. Visual acuity of all patients remained stable during the follow up period. One year postoperatively the corneal graft remained in place and no signs of inflammation were evident, while all grafts were epithelialized. Conclusions: The use of cross-linked corneal graft for the tectonic reconstruction of the anterior ocular segment represents an adequate surgical approach for the management of scleral and conjuctival melting; while, at the same time it offers the advantage of using one corneal graft for two recipients. PMID:24278090

  5. Human fibrin tissue adhesive for sutureless lamellar keratoplasty and scleral patch adhesion: a pilot study.

    PubMed

    Kaufman, Herbert E; Insler, Michael S; Ibrahim-Elzembely, Hosan A; Kaufman, Stephen C

    2003-11-01

    To determine whether a fibrin adhesive can facilitate the performance of sutureless lamellar keratoplasty and attachment of amnion to bare sclera. Prospective, noncomparative case series. Six patients, 5 of whom underwent lamellar keratoplasty and 1 who received an amniotic patch of the sclera and cornea. Institutional review board approval was not required for these therapeutic treatments. In 5 patients, the epithelium was removed from the corneal surface, a free cap, 200- micro m thick, was cut with a microkeratome, and a human fibrin tissue adhesive (Tisseel VH Fibrin Sealant; Baxter Healthcare Corporation, Glendale, CA) was applied to the cut surface of the corneal stroma. A 200- micro m thick, microkeratome-cut lamellar graft was placed in the stromal bed without sutures, and a bandage soft contact lens was applied. The lens was left in place for 1 week and then removed. In 1 patient, the adhesive was applied to bare sclera for attachment of amniotic membrane after removal of a conjunctival melanosis. All patients were followed up for 3 months after surgery. Tissue adhesion, corneal clarity, and visual acuity. All 5 lamellar grafts healed and remained clear, although final visual acuity varied with visual potential and astigmatism. The amniotic membrane graft also adhered well to the bare sclera. The fibrin adhesive provided satisfactory attachment without sutures for lamellar keratoplasty and amniotic patching. It should be effective for sealing of clear cornea incisions, LASIK flaps, and conjunctival and skin grafts. An adhesive that has been designed specifically for ophthalmic applications and is more convenient to use would be desirable.

  6. The efficacy of a single continuous nylon suture for control of post keratoplasty astigmatism.

    PubMed Central

    Van Meter, W

    1996-01-01

    PURPOSE: Post operative adjustment of a single continuous suture is an effective means of reducing post keratoplasty astigmatism. This study evaluates post keratoplasty keratometry following suture adjustment with an adjusted suture in place and after the suture is removed. METHODS: Average keratometric astigmatism was measured over 24 months time in 26 patients with an adjusted continuous suture and 24 patients with a continuous suture that was not adjusted. Average keratometry in 43 patients with an adjusted continuous suture was compared with 37 patients with combined continuous and interrupted sutures. Finally, suture out astigmatism in 19 adjusted patients was compared to six patients with no adjustment. RESULTS: There was an increase in average corneal astigmatism over two years of 2.2 diopters in the adjusted group and 1.7 diopters in the non-adjusted group with sutures in place. One year following surgery, average keratometry flattened from 47.5 to 42.9 diopters in the adjusted continuous group and from 47.0 to 46.0 diopters in the group with combined continuous and interrupted sutures. Following suture removal, average astigmatism in patients who had suture adjustment was 4.4 diopters +/- 2.5 diopters (range 1-10 diopters), and 6.01 diopters (range 4-7) in the non-adjusted group. CONCLUSIONS: Average post keratoplasty astigmatism increases after a continuous suture is adjusted but the increase is comparable to patients with acceptable astigmatism who do not require adjustment. More progressive corneal flattening over 12 months time is seen with a continuous suture than which combined sutures. Average suture out astigmatism was 4.0 diopters following suture adjustment, compared to an average of 8.4 diopters prior to adjustment. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 7A FIGURE 7B PMID:8981721

  7. Efficacy and safety of deep anterior lamellar keratoplasty vs. penetrating keratoplasty for keratoconus: a meta-analysis.

    PubMed

    Liu, Hao; Chen, Yihui; Wang, Peng; Li, Bing; Wang, Weifang; Su, Yan; Sheng, Minjie

    2015-01-01

    To evaluate difference in therapeutic outcomes between deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PKP) for the clinical treatment of keratoconus. A comprehensive search was conducted in Pubmed, EMBASE, Cochrane Library, and Web of science. Eligible studies should include at least one of the following factors: best corrected visual acuity (BCVA), postoperative spherical equivalent (SE), postoperative astigmatism and endothelial cell count (ECC), central corneal thickness (CCT), graft rejection and graft failure, of which BCVA, graft rejection and graft failure were used as the primary outcome measures, and postoperative SE, astigmatism, CCT and ECC as the secondary outcome measures. Given the lack of randomized clinical trials (RCTs), cohort studies and prospective studies were considered eligible. Sixteen clinical trials involving 6625 eyes were included in this review, including 1185 eyes in DALK group, and 5440 eyes in PKP group. The outcomes were analyzed using Cochrane Review Manager (RevMan) version 5.0 software. The postoperative BCVA in DALK group was significantly better than that in PKP group (OR = 0.48; 95%CI 0.39 to 0.60; p<0.001). There were fewer cases of graft rejection in DALK group than those in PKP group (OR = 0.28; 95%CI 0.15 to 0.50; p<0.001). Nevertheless the rate of graft failure was similar between DALK and PKP groups (OR = 1.05; 95%CI 0.81 to 1.36; p = 0.73). There were no significant differences in the secondary outcomes of SE (p = 0.70), astigmatism (p = 0.14) and CCT (p = 0.58) between DALK and PKP groups. And ECC in DALK group was significantly higher than PKP group (p<0.001). The postoperative complications, high intraocular pressure (high-IOP) and cataract were analyzed, fewer cases of complications occurred in DALK group than those in PKP group (high-IOP, OR 0.22, 95% CI 0.11-0.44, P<0.001) (cataract, OR 0.22; 95% CI 0.08-0.61, P = 0.004). And no cases of expulsive hemorrhage and endophthalmitis were

  8. Salvaging deep anterior lamellar keratoplasty with microbubble incision technique in failed "big bubble" cases: an update study.

    PubMed

    Banerjee, Sanjib; Li, He J; Tsaousis, Konstantinos T; Tabin, Geoffrey C

    2016-11-04

    To report the achievement rate of bare Descemet membrane (DM) dissection with the help of microbubble incision technique in eyes with failed big bubble formation and to investigate the mechanism of the microbubble rescue technique through ex vivo imaging of human cadaver corneas. This retrospective clinical study included 80 eyes of 80 patients that underwent deep anterior lamellar keratoplasty (DALK). In 22/80 (27.5%) cases, big bubble dissection failed. After puncturing the microbubbles, viscodissection helped to achieve separation of DM from the remaining stroma. In addition, an ex vivo study with human cadaver cornea specimens, gross photography, and anterior segment optical coherence tomography imaging was accomplished ex vivo to explore the mechanism of this method. Microbubble dissection technique led to successful DALK in 19 of 22 cases of failed big bubble. Microperforation occurred in 3 eyes. Deep anterior lamellar keratoplasty was completed without any complications in 2 out of the 3 eyes with microperforation. In 1 eye, conversion to penetrating keratoplasty was required. Microbubble-guided viscodissection achieved 95.4% (21/22) success in exposing bare DM in failed big-bubble cases of DALK. Anterior segment optical coherence tomography imaging results of cadaver eyes showed where these microbubbles were concentrated and their related size. Microbubble-guided DALK should be considered an effective rescue technique in achieving bare DM in eyes with failed big bubble. Our ex vivo experiment illustrated the possible alterations in cornea anatomy during this technique.

  9. Evaluation of the Role of Umbilical Cord Serum and Autologous Serum Therapy in Reepithelialization After Keratoplasty: A Randomized Controlled Clinical Trial.

    PubMed

    Kamble, Neha; Sharma, Namrata; Maharana, Prafulla K; Bandivadekar, Pooja; Nagpal, Ritu; Agarwal, Tushar; Velpandian, Thirumurthy; Mittal, Suneeta; Vajpayee, Rasik B

    2017-09-01

    To evaluate the role of umbilical cord serum (UCS) and autologous serum (AS) therapy in reepithelialization of corneal graft after keratoplasty in a randomized controlled trial. A total of 105 eyes with epithelial defect (ED) after keratoplasty (penetrating keratoplasty-67 and anterior lamellar keratoplasty-38) on the first postoperative day were included in the study. The eyes were randomized into three groups: UCS (n=35), AS (n=35), and artificial tears (AT) (n=35). All patients received standard postoperative medical therapy. The primary outcome measure was time to epithelialization, and secondary outcome measures were best-corrected visual acuity and graft clarity. The ED healed completely in 103 eyes. The mean time for complete reepithelialization was 2.5±2.1, 3.1±2.2, and 4.5±1.4 days in UCS, AS, and AT groups, respectively. The mean percentage decrease in the size of the ED was significantly better in the UCS and AS groups as compared with the AT group (P=0.001). The rate of reepithelialization was comparable between the AS and UCS groups (P=0.3). On bivariate analysis, significant correlation was found between the mean size of postoperative ED, grade of the donor cornea (P=0.001), and the presence of preoperative ED (P=0.001). No complications were associated with the use of serum therapy. Most of the cases of postkeratoplasty corneal ED can be managed with AT only. The serum therapy (AS/UCS) helps in the faster reepithelialization of postkeratoplasty ED as compared with AT and may be considered as a treatment option for early epithelial healing.

  10. The Results of Toric Intraocular Lens Implantation in Patients With Cataract and High Astigmatism After Penetrating Keratoplasty.

    PubMed

    Müftüoğlu, İlkay Klç; Akova, Yonca Aydn; Egrilmez, Sait; Yilmaz, Suzan Guven

    2016-03-01

    To evaluate the results of toric intraocular lens (IOL) implantation in patients with cataract and postpenetrating keratoplasty astigmatism. Seven eyes of 7 patients with cataract and more than 3.5 diopters (D) astigmatism following penetrating keratoplasty were included in this retrospective case series study. All of the eyes underwent phacoemulsification and Acrysof toric IOL (t5-t9) implantation at least 6 months later than the complete suture removal. Corrected visual acuity (CVA), manifest astigmatism, the keratometry measurements, and complications were assessed. The mean preoperative CVA significantly increased (0.7±0.3 [range: 0.3-1.3] logMAR to 0.1±0.04 [range: 0.05-0.15] logMAR; P<0.05) at mean 8.71±4.11 months after the surgery. The mean preoperative corneal astigmatism and the average manifest refractive astigmatism at the last visit were 5.4±0.9 D (range: 4.25-7 D) and 1.6±0.6 D (range: 0.5-2.5 D), respectively. The mean attempted cylinder correction at spectacle plane was 4.3±0.9 D (range: 2.4-4.7 D) whereas the mean cylinder correction was 4.6±0.5 D (range: 3.9-5.9 D), showing a slightly tendency for overcorrection. All eyes (100%) were within 1 D of predicted residual astigmatism. No complication occurred during the follow-up. Toric IOL implantation seems to be an effective, predictable, and safe procedure in patients with cataract formation and high astigmatism after penetrating keratoplasty.

  11. Femtosecond laser-assisted deep anterior lamellar keratoplasty with big-bubble technique for keratoconus.

    PubMed

    Lu, Yan; Chen, Xiangfei; Yang, Liping; Xue, Chunyan; Huang, Zhenping

    2016-09-01

    The purpose of this study was to evaluate the clinical results after deep anterior lamellar keratoplasty (DALK) assisted by the femtosecond laser with big-bubble technique for keratoconus. A case series of 22 eyes in 19 patients with keratoconus was enrolled in the study. The 500-kHz VisuMax femtosecond laser (Carl Zeiss Meditec AG, Jena, Germany) was used to create a vertical side cut on donor and recipient corneas. Intraoperative and postoperative complications, uncorrected visual acuity, best-corrected visual acuity, corneal curvature, and central corneal thickness were evaluated in all patients. Big-bubble and naked Descemet's membrane (DM) were successfully achieved in twenty eyes (90.9%). Intraoperative macroperforation of DM occurred in two cases and converted to full-thickness keratoplasty. The mean follow-up time was 18.8 ± 5.3 months. The best-corrected visual acuity was increased from 0.3 to 1.0, mean corneal curvature was 43.0 ± 2.3D, and mean central corneal thickness was 508.9 ± 60.1 μm (range, from 430 to 600 μm) postoperatively. Our results indicate that femtosecond laser-assisted DALK with big-bubble technique is an accurate, safe, and effective method to treat the patients with keratoconus.

  12. New refractive method for laser thermal keratoplasty with the Co:MgF2 laser.

    PubMed

    Horn, G; Spears, K G; Lopez, O; Lewicky, A; Yang, X Y; Riaz, M; Wang, R; Silva, D; Serafin, J

    1990-09-01

    We have observed corneal curvature changes from laser thermal keratoplasty with a Co:MgF2 laser. We studied corneal curvature changes in rabbits and have identified specific treatment patterns and laser parameters that can correct myopia and astigmatism. These corneal changes, some as large as 8 diopters, have been stable for at least one year, and slitlamp examination demonstrates clear central corneas with normal appearance.

  13. Young donor-graft assisted endothelial keratoplasty (PDEK/DMEK) with epithelial debridement for chronic pseudophakic bullous keratopathy.

    PubMed

    Agarwal, Amar; Narang, Priya; Kumar, Dhivya A; Agarwal, Ashvin

    2017-10-01

    The aim of this study was to describe the applicability and report visual outcomes for the treatment of subepithelial fibrosis and anterior stromal scarring in cases of chronic pseudophakic bullous keratopathy (PBK) with epithelial debridement and endothelial keratoplasty (EK) (pre-Descemet endothelial keratoplasty [PDEK]; Descemet membrane endothelial keratoplasty [(DMEK]) using young donor tissue. Prospective, single-centre, interventional study. 6 cases with chronic PBK (> 1 year duration). Case 1 underwent PDEK with glued intraocular lens (IOL) as a single-stage procedure, whereas cases 2 and 3 underwent glued IOL followed by DMEK and PDEK, respectively, as a second-stage procedure. Cases 4 and 6 underwent PDEK, whereas case 5 underwent DMEK. Epithelial debridement was performed in all cases at the time of EK, and young donor grafts were used. The main outcome measures were best spectacle-corrected visual acuity, clearance of corneal scar and haze, central corneal thickness (CCT), specular microscopy, and endothelial cell count (ECC). Postoperatively, all cases demonstrated significant improvement in visual acuity. The mean value of depth of subepithelial haze was 121±71.7 µm and 25.3 ± 19.8 µm in the preoperative and postoperative periods, respectively (p = 0.028). At the 1-month follow-up, the mean preoperative CCT of 676 ± 92.7 µm was reduced to 534.6 ± 21.1µm. At the 6-month follow-up, the mean ECC loss resulting from the procedure was 36.5 ± 10.4%. EK with epithelial debridement performed for the treatment of chronic PBK resulted in significantly improved visual acuity to a functional level, with the clearance of subepithelial fibrosis and anterior stromal scar, in most patients. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  14. Long-term follow-up of astigmatic keratotomy for corneal astigmatism after penetrating keratoplasty.

    PubMed

    Böhringer, Daniel; Dineva, Nina; Maier, Philip; Birnbaum, Florian; Kirschkamp, Thomas; Reinhard, Thomas; Eberwein, Philipp

    2016-11-01

    To report the long-term stability of paired arcuate corneal keratotomies (AKs) in patients with high regular postpenetrating keratoplasty astigmatism. Retrospective chart review of best-corrected visual acuity, refraction and keratometric values of 41 eyes with AK between 2003 and 2012. Magnitude of median target induced astigmatism vector was 9.2 dioptres (Dpt). We reached a median magnitude of surgically induced astigmatism vector of 9.81 Dpt and a median magnitude of difference vector of 5.5 Dpt. In keratometry, we achieved a net median astigmatism reduction by 3.3 Dpt. The average correction index was 1.14, showing a slight overcorrection. Irregularity of keratometric astigmatism increased by 0.6 Dpt, and spherical equivalent changed by 1.75 Dpt. Monocular best spectacle corrected visual acuity increased from preoperatively 20/63 (0.5 logMAR) to 20/40 (0.3 logMAR) postoperatively. Median gain on the ETDRS chart was two lines. Long-term follow-up showed a median keratometric astigmatic increase by 0.3 Dpt per year. Arcuate corneal keratotomies is a safe and effective method to reduce high regular corneal astigmatism following penetrating keratoplasty but has limited predictability. The long-term follow-up shows an increase of keratometric astigmatism by 0.3 Dpt/year, equalizing the surgical effect after 10 years. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  15. Corneal collagen cross-linking in the stabilization of PRK, LASIK, thermal keratoplasty, and orthokeratology.

    PubMed

    Nguyen, Michelle K; Chuck, Roy S

    2013-07-01

    To describe the use of corneal collagen cross-linking (CXL) and its efficacy in the stabilization of keratorefractive procedures, including PRK, laser in-situ keratomileusis (LASIK), thermal keratoplasty, and orthokeratology. Since its introduction, CXL has quickly gained interest in the treatment of ectactic disorders due to its ability to increase the biomechanical stability of the cornea. In its earliest use, it has shown to be effective in the treatment of both keratoconus and post-LASIK ectasia. More recent studies of CXL in combination with keratorefractive procedures have shown varying degrees of success. CXL with PRK has shown to be effective in slowing or halting the progression of keratoconus, pellucid marginal degeneration, and post-LASIK ectasia, in addition to potentially decreasing or delaying the need for penetrating keratoplasty. Several small case series have also demonstrated improved stability and efficacy of PRK and LASIK when combined with CXL, as well as a potentially decreased risk of postprocedure ectasia. In conjunction with thermokeratoplasty and orthokeratology, CXL has shown improved but only temporary results in the treatment of keratoconus. Future studies are needed to determine the efficacy and long-term stability of CXL in combination with keratorefractive procedures, as well as to address possible complications.

  16. Combined astigmatic keratotomy and conductive keratoplasty to correct high corneal astigmatism.

    PubMed

    Sy, Mary Ellen; Kovoor, Timmy A; Tannan, Anjali; Choi, Daniel; Deng, Sophie X; Danesh, Jennifer; Hamilton, D Rex

    2015-05-01

    To determine the safety, efficacy, and predictability of combined astigmatic keratotomy (AK) and conductive keratoplasty (CK) for treating high corneal astigmatism. University of California-Los Angeles, Los Angeles, California, USA. Retrospective case series. From January 1, 2004, to December 31, 2009, AK and CK were performed in eyes with corneal astigmatism of 5.0 diopters (D) or more after keratoplasty or trauma. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, spherical equivalent (SE), defocus equivalent, mean astigmatism, efficacy index, and complications were evaluated. In 11 eyes of 11 patients, the mean UDVA improved from 1.54 logMAR ± 0.50 (SD) preoperatively to 0.69 ± 0.62 logMAR 3 months postoperatively (P < .001) and the mean CDVA from 0.55 ± 0.62 logMAR to 0.12 ± 0.11 logMAR (P = .028). The mean SE and mean defocus equivalent decreased from -1.25 ± 5.06 D to 3.13 ± 3.06 D (P = .15) and from 7.98 ± 4.41 D to 6.97 ± 3.73 D (P = .45), respectively; these changes were not statistically significant. The mean absolute astigmatism decreased from 10.25 ± 4.71 D to 4.31 ± 2.34 D (P < .001). The mean absolute orthogonal and mean oblique astigmatism showed a statistically significant decrease. The efficacy index was 0.82. One case of wound gape after AK required suturing. No infectious keratitis, corneal perforation, or graft rejection occurred. Results indicate that combined AK and CK is safe and effective for correcting high corneal astigmatism after surgery or trauma. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Rate and Localization of Graft Detachment in Descemet Membrane Endothelial Keratoplasty.

    PubMed

    Maier, Anna-Karina B; Gundlach, Enken; Pilger, Daniel; Rübsam, Anne; Klamann, Matthias K J; Gonnermann, Johannes; Bertelmann, Eckart; Joussen, Antonia M; Torun, Necip

    2016-03-01

    To investigate the rate and localization of graft detachment after Descemet membrane endothelial keratoplasty. Sixty-six consecutive cases operated between June and August 2014 at the Charité-Universitätsmedizin Berlin were examined prospectively 1 week postoperatively. A single masked observer analyzed the rate and localization of graft detachment using optical coherence tomography (OCT), and the rebubbling rate was measured. Localization of graft detachment was correlated to the incision approach. Preoperative data were correlated to the rate of graft detachment and rebubbling. Graft detachment occurred in more than 2 clock hours and with postoperative corneal edema in 33.3% and required rebubbling. In 33.3%, graft detachment occurred in more than 2 clock hours and with postoperative corneal edema and required rebubbling. The mean graft detachment rate was 8.3% per clock hour. A significantly higher graft detachment rate was noted in the inferior clock hours (21.1%, P < 0.0001, 16.7%, P = 0.003). Only higher age of the patient correlated to a higher rate of graft detachment (P = 0.022). No correlation was found between localization of graft detachment and the incision approach (P = 0.615). The graft detachment rate is high after Descemet membrane endothelial keratoplasty, but detachment is usually peripheral, partial and mainly inferior and involves only a few clock hours. Only higher age of the patient is strongly associated with a higher rate of graft detachment. The incision approach is not significantly correlated with the localization of graft detachment. Therefore, the postoperative supine position of the patient seems to be of major importance.Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT02020044.

  18. Visual acuity, refractive error, and endothelial cell density 6 and 12 months after deep lamellar endothelial keratoplasty.

    PubMed

    Fillmore, Parley D; Sutphin, John E; Goins, Kenneth M

    2010-06-01

    To report the visual acuity, refractive outcome, and endothelial cell density (ECD) up to 1 year after deep lamellar endothelial keratoplasty (DLEK) in a large prospective series. Eighty-six DLEK procedures were performed and evaluated in a prospective interventional case series. Subgroup analysis was performed to compare results from large-incision (9 mm) DLEK (n = 7), small-incision (5-8 mm) DLEK (n = 70), and penetrating keratoplasty (PKP) conversion (n = 9). Outcome measures included best-corrected visual acuity (BCVA), manifest refraction, corneal topographic astigmatism, and ECD. The percentage of eyes that achieved a BCVA of 20/40 or better after DLEK was 55% at 6 months, increasing to 61% at 1 year. Topographic astigmatism and spherical equivalent were not significantly different than preoperative measurements up to 1 year after DLEK (P > 0.05). An endothelial cell loss of 40% at 6 months and 48% by 1 year was observed. The mean ECD after DLEK was 1831 +/- 472 cells per square millimeter at 6 months and 1569 +/- 601 cells per square millimeter at 12 months. When evaluated by incision size, the ECD was better at 2066 +/- 558 cells per square millimeter with a 9-mm incision compared with only 1516 +/- 585 cells per square millimeter with a smaller incision at 1 year, although this did not reach significance (P = 0.075). The endothelial cell loss after penetrating keratoplasty conversion was similar to that in the large-incision group (P > 0.05). DLEK provides good visual acuity (> or =20/40) for the majority of patients at 1 year with stable refractive error compared with baseline. Refractive stability was observed with both large- and small-incision DLEKs; however, worrisome endothelial cell loss was observed, especially with a small-incision technique.

  19. Comparison of synthetic glues and 10-0 nylon in rabbit lamellar keratoplasty.

    PubMed

    Cho, Soon Young; Kim, Man Soo; Oh, Su Ja; Chung, Sung Kun

    2013-09-01

    To evaluate changes in mean keratometry and to compare wound repair with corneal lamellar grafts in rabbit eyes using human synthetic tissue adhesives and 10-0 nylon. Corneal grafts were made using a 6.0-mm-diameter trephine and blades in the eyes of 15 New Zealand white rabbits. Human fibrin tissue adhesive (Tisseel) was used in group 1, human fibrin tissue adhesive (Beriplast P) was used in group 2, polyethylene glycol adhesive (Coseal) was used in group 3, and 8 bite sutures with 10-0 nylon were used in group 4 (control) for lamellar keratoplasty. Four bite sutures were made with 10-0 nylon in groups 1, 2, and 3. Slit-lamp microscopy and keratometry were performed at 3 days and 1, 2, and 4 weeks after the surgery. Histopathologic and electromicroscopic examinations were performed 4 weeks after the surgery. No inflammation or corneal toxicity was seen in groups 1 and 2. Histologically, a few inflammatory cells were seen in groups 3 and 4. Groups 1, 2, and 3 showed no statistically significant changes in mean keratometry at 4 weeks postoperatively compared with preoperative mean keratometry (Wilcoxon signed-rank test, P = 0.178, 0.208, and 0.889, respectively). The control group showed significant changes in mean keratometry at 4 weeks postoperatively (Wilcoxon signed-rank test, P = 0.018). Human fibrin tissue adhesives were well tolerated in rabbit eyes, with no apparent corneal toxicity. Polyethylene glycol adhesive showed more inflammation and insufficient wound repair compared with human fibrin tissue adhesives. Therefore, human fibrin tissue adhesives can be used as an alternative to sutures in lamellar keratoplasty.

  20. [Sutureless lamellar keratoplasty by microkeratome combined with fibrin tissue adhesive in rabbits].

    PubMed

    Chen, Wei; Qu, Jia; Lu, Fan; Zhu, Ren-yuan

    2004-05-01

    To evaluate the feasibility and safety of sutureless lamellar keratoplasty by microkeratome combined with fibrin tissue adhesive. Twenty-four New Zealand white rabbits were divided into two groups, the donor grafts and recipient beds were made by the microkeratome, the grafts were glued over the stoma bed using the commercial product Tisseel in one group; and grafts without tissue adhesive were used as the control group. Corneal refractive power was measured by automated keratometer preoperatively and in 3 days, 2 weeks, 1 and 3 months postoperatively. Rejection and cornea transparency were observed. Confocal microscopy was used to observe corneal wound healing response and to measure the keratocyte and endothelium densities in vivo. Corneal wound healing was also evaluated using light and fluorescence microscopy. Ninety-two percent (11/12 eyes) of the glued grafts were retained in the Tisseel group, whereas all grafts were lost in the control group. All survived grafts were clear 1 month after surgery. However, in the control group, severe haze in the grafts occurred 2 weeks postoperatively. Confocal microscopy showed that there was a significant decrease of the keratocyte density surrounding the lenticule-host interface, and no changes occurred in the posterior keratocyte and endothelium. Histopathologic observations demonstrated the presence of a line of amorphous eosinophilic substance in the lenticule-host interface at 3 days after surgery, but the line disappeared after 1 month. Fluorescence microscopy showed no detectable regenerated stromal tissue. This initial study demonstrates sutureless optical lamellar keratoplasty performed by microkeratome combined with fibrin tissue adhesive is a simple and safe technique. Stromal wound healing response to this surgery is minimal. Fibrin tissue adhesive has no influence on the cornea optical property.

  1. A chandelier-illuminated anterior chamber maintainer for use during descemet stripping automated endothelial keratoplasty in patients with advanced bullous keratopathy.

    PubMed

    Inoue, Tomoyuki; Oshima, Yusuke; Hori, Yuich; Maeda, Naoyuki

    2010-08-01

    A new 25-gauge illuminated anterior chamber maintainer composed of a 25-gauge infusion cannula through which a 29-gauge chandelier fiber probe passes was developed for use during Descemet stripping automated endothelial keratoplasty to treat patients with advanced bullous keratopathy. This device, which is compatible with a xenon or mercury vapor illuminator to generate powerful wide-angle illumination from the cone-shaped chandelier fiber tip, is self-retained at the corneal limbus after insertion of the infusion cannula through a corneal side port. Because of its bifunctionality, that is, bright illumination and adequate irrigation flow, excellent visibility with stable anterior chamber maintenance can be concurrently obtained for Descemet stripping, endothelial graft insertion, and subsequent intraocular manipulations without the need for use of a biologic staining technique or ophthalmic viscosurgical products even in patients with severe corneal haze. This new device facilitates safe and simple intraocular manipulation during Descemet stripping automated endothelial keratoplasty.

  2. Asymptomatic Infection in Decompensated Full-Thickness Corneal Grafts Referred for Repeat Penetrating Keratoplasty.

    PubMed

    Nahum, Yoav; Leon, Pia; Ricci-Filipovic, Benedetta Azzurra; Camposampiero, Davide; Ponzin, Diego; Busin, Massimo

    2017-04-01

    We report a case series of asymptomatic infections affecting failed corneal grafts in patients referred for repeat penetrating keratoplasty (PK). In this retrospective, noncomparative, interventional case series, we reviewed the medical records of all repeat PK procedures performed at Villa Serena-Villa Igea private Hospitals (Forlì, Italy) between January 2011 and March 2016. Specifically, preoperative and postoperative slit-lamp examinations, and the results of histological and bacteriological examinations, were noted. Fifty-three repeat PKs were performed in the study period. All patients were referred because of long-standing graft decompensation with stromal scars or surface irregularities, thus unsuitable for endothelial keratoplasty. None was referred because of presumed infection. Histological examination of the explanted buttons showed the presence of microorganisms of various types in 7 eyes. Cultures were positive in 4 of these cases and in one additional case Staphylococcus aureus was grown in culture, but was not seen in the histology specimen. None of the patients presented with unusual pain, tearing, or discomfort. Preoperative abnormal clinical findings included epithelial defect (n = 6), focal whitening of corneal stroma (n = 5), crystalline keratopathy (n = 1), and an elevated pigmented lesion (n = 1). After repeat PK, recurrence of the infection was seen in 5 of 7 (71%) cases, 2 of which required a third PK procedure. Apparently quiet eyes with failed PK can harbor slow-growing asymptomatic infection. An epithelial defect in a failed PK graft should raise suspicion of infection. Routine cultures and histological examination of the excised corneal buttons are instrumental in the diagnosis of these infections and can guide further treatment.

  3. In situ ultrahigh-resolution optical coherence tomography characterization of eye bank corneal tissue processed for lamellar keratoplasty.

    PubMed

    Brown, Jamin S; Wang, Danling; Li, Xiaoli; Baluyot, Florence; Iliakis, Bernie; Lindquist, Thomas D; Shirakawa, Rika; Shen, Tueng T; Li, Xingde

    2008-08-01

    To use optical coherence tomography (OCT) as a noninvasive tool to perform in situ characterization of eye bank corneal tissue processed for lamellar keratoplasty. A custom-built ultrahigh-resolution OCT (UHR-OCT) was used to characterize donor corneal tissue that had been processed for lamellar keratoplasty. Twenty-seven donor corneas were analyzed. Four donor corneas were used as controls, whereas the rest were processed into donor corneal buttons for lamellar transplantation by using hand dissection, a microkeratome, or a femtosecond laser. UHR-OCT was also used to noninvasively characterize and monitor the viable corneal tissue immersed in storage medium over 3 weeks. The UHR-OCT captured high-resolution images of the donor corneal tissue in situ. This noninvasive technique showed the changes in donor corneal tissue morphology with time while in storage medium. The characteristics of the lamellar corneal tissue with each processing modality were clearly visible by UHR-OCT. The in situ characterization of the femtosecond laser-cut corneal tissue was noted to have more interface debris than shown by routine histology. The effects of the femtosecond laser microcavitation bubbles on the corneal tissue were well visualized at the edges of the lamellar flap while in storage medium. The results of our feasibility study show that UHR-OCT can provide superb, in situ microstructural characterization of eye bank corneal tissue noninvasively. The UHR-OCT interface findings and corneal endothelial disc thickness uniformity analysis are valuable information that may be used to optimize the modalities and parameters for lamellar tissue processing. The UHR-OCT is a powerful approach that will allow us to further evaluate the tissue response to different processing techniques for posterior lamellar keratoplasty. It may also provide information that can be used to correlate with postoperative clinical outcomes. UHR-OCT has the potential to become a routine part of tissue

  4. Characterization of triple layers

    NASA Astrophysics Data System (ADS)

    Otero, Toribio F.; Cortes, M. Teresa

    2001-07-01

    We reported the characterization of a macroscopic electrochemomechanical actuator like triple layer (3x1 cm) formed by polypyrrole)/double- sided, non-conducting and flexible tape/ polypyrrole that works in liquid electrolytes under electrochemical control. This triple layer has characteristics of artificial muscle. The influence of variables that control the volume change in the polymer as electrolyte concentration, or temperature has been studied. Variations of time, energy and charge under different conditions are described. We have found that the triple layer acts, at the same time, as sensor and actuator. Therefore, physical magnitudes like the electrolyte concentration or the temperature in the cell can be obtained from electrical energy consumed by a muscle. We have evaluated the influence of variables as area of the triple layer or the trailing weight, which don't participate in the electrochemical reaction. We propose an explication to the results, which show a correlation between the trailed mass and the consumed charge required to move a constant angle those masses by the triple layer. When different surface areas of the triple layer has been evaluated we found that the consumed electrical charge is proportional to area (the mass) of the triple layer. The triple layer can make macroscopical movements in short times, their position is absolutely controlled with the electrical charge, and it has capacity to lift masses. These characteristics allow their use in the design of tools. So, we present a macroscopic tool constituted by two triple layers, which allows catch and translate objects in liquid medium (nipper).

  5. Toxic anterior segment syndrome following penetrating keratoplasty.

    PubMed

    Maier, Philip; Birnbaum, Florian; Böhringer, Daniel; Reinhard, Thomas

    2008-12-01

    To describe an outbreak of toxic anterior segment syndrome (TASS) following penetrating keratoplasty (PK) and to examine its possible causes. Owing to a series of TASS following PK between June 6, 2007, and October 2, 2007, we reviewed the records of all patients who had undergone PK during that time. In addition to routine microbial tests on organ culture media, we looked for specific pathogens and endotoxins in all of the materials used for organ culture or PK. Furthermore, we analyzed all of the perioperative products and instrument processing. Of the 94 patients who underwent PK, we observed 24 cases of postoperative sterile keratitis. Causal research revealed that the accumulation of cleaning substances or heat-stable endotoxins on the surface of the routinely used guided trephine system was most likely responsible for the TASS. To our knowledge, this is the first report on TASS following PK. Suboptimal reprocessing of surgical instruments may be an important cause of TASS as in this series the TASS-like symptoms resolved after modified instrument-cleaning procedures. The standardization of protocols for processing reusable trephine systems might prevent outbreaks of TASS following PK.

  6. [Astigmatic keratotomy with the femtosecond laser: correction of high astigmatisms after keratoplasty].

    PubMed

    Kook, D; Bühren, J; Klaproth, O K; Bauch, A S; Derhartunian, V; Kohnen, T

    2011-02-01

    The purpose of this study was to evaluate a novel technique for the correction of postoperative astigmatism after penetrating keratoplasty with the use of the femtosecond laser creating astigmatic keratotomies (femto-AK) in the scope of a retrospective case series. Clinical data of ten eyes of nine patients with high residual astigmatism after penetrating keratoplasty undergoing paired femto-AK using a 60-kHz femtosecond laser (IntraLase™, AMO) were analyzed. A new software algorithm was used to create paired arcuate cuts deep into the donor corneal button with different cut angles. Target values were refraction, uncorrected visual acuity, best corrected visual acuity, topographic data (Orbscan®, Bausch & Lomb, Rochester, NY, USA), and corneal wavefront analysis using Visual Optics Lab (VOL)-Pro 7.14 Software (Sarver and Associates). Vector analysis was performed using the Holladay, Cravy and Koch formula. Statistical analysis was performed to detect significances between visits using Student's t test. All procedures were performed without any major complications. The mean follow-up was 13 months. The mean patient age was 48.7 years. The preoperative mean uncorrected visual acuity (logMAR) was 1.27, best corrected visual acuity 0.55, mean subjective cylinder -7.4 D, and mean topometric astigmatism 9.3 D. The postoperative mean uncorrected visual acuity (logMAR) was 1.12, best corrected visual acuity 0.47, mean subjective cylinder -4.1 D, and mean topometric astigmatism 6.5 D. Differences between corneal higher order aberrations showed a high standard deviation and were therefore not statistically significant. Astigmatic keratotomy using the femtosecond laser seems to be a safe and effective tool for the correction of higher corneal astigmatisms. Due to the biomechanical properties of the cornea and missing empirical data for the novel femto-AK technology, higher numbers of patients are necessary to develop optimal treatment nomograms.

  7. Update on the Management of High-Risk Penetrating Keratoplasty

    PubMed Central

    Jabbehdari, Sayena; Rafii, Alireza Baradaran; Yazdanpanah, Ghasem; Hamrah, Pedram; Holland, Edward J.; Djalilian, Ali R

    2017-01-01

    Purpose of review In this article, we review the indications and latest management of high-risk penetrating keratoplasty. Recent findings Despite the immune-privilege status of the cornea, immune-mediated graft rejection still remains the leading cause of corneal graft failure. This is particularly a problem in the high-risk graft recipients, namely patients with previous graft failure due to rejection and those with inflamed and vascularized corneal beds. A number of strategies including both local and systemic immunosuppression are currently used to increase the success rate of high-risk corneal grafts. Moreover, in cases of limbal stem cell deficiency, limbal stem cells transplantation is employed. Summary Corticosteroids are still the top medication for prevention and treatment in cases of corneal graft rejection. Single and combined administration of immunosuppressive agents e.g. tacrolimus, cyclosporine and mycophenolate are promising adjunctive therapies for prolonging graft survival. In the future, cellular and molecular therapies should allow us to achieve immunologic tolerance even in high-risk grafts. PMID:28959505

  8. Update on the Management of High-Risk Penetrating Keratoplasty.

    PubMed

    Jabbehdari, Sayena; Rafii, Alireza Baradaran; Yazdanpanah, Ghasem; Hamrah, Pedram; Holland, Edward J; Djalilian, Ali R

    2017-03-01

    In this article, we review the indications and latest management of high-risk penetrating keratoplasty. Despite the immune-privilege status of the cornea, immune-mediated graft rejection still remains the leading cause of corneal graft failure. This is particularly a problem in the high-risk graft recipients, namely patients with previous graft failure due to rejection and those with inflamed and vascularized corneal beds. A number of strategies including both local and systemic immunosuppression are currently used to increase the success rate of high-risk corneal grafts. Moreover, in cases of limbal stem cell deficiency, limbal stem cells transplantation is employed. Corticosteroids are still the top medication for prevention and treatment in cases of corneal graft rejection. Single and combined administration of immunosuppressive agents e.g. tacrolimus, cyclosporine and mycophenolate are promising adjunctive therapies for prolonging graft survival. In the future, cellular and molecular therapies should allow us to achieve immunologic tolerance even in high-risk grafts.

  9. Corneal perforation after conductive keratoplasty with previous refractive surgery.

    PubMed

    Kymionis, George D; Titze, Patrik; Markomanolakis, Marinos M; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-12-01

    A 56-year-old woman had conductive keratoplasty (CK) for residual hyperopia and astigmatism. Three years before the procedure, the patient had arcuate keratotomy, followed by laser in situ keratomileusis 2 years later for high astigmatism correction in both eyes. During CK, a corneal perforation occurred in the right eye; during the postoperative examination, an iris perforation and anterior subcapsule opacification were seen beneath the perforation site. The perforation was managed with a bandage contact lens and an antibiotic-steroid ointment; it had a negative Seidel sign by the third day. The surgery in the left eye was uneventful. Three months after the procedure, the uncorrected visual acuity was 20/32 and the best corrected visual acuity 20/20 in both eyes with a significant improvement in corneal topography. Care must be taken to prevent CK-treated spots from coinciding with areas in the corneal stroma that might have been altered by previous refractive procedures.

  10. Simultaneous topography-guided PRK followed by corneal collagen cross-linking after lamellar keratoplasty for keratoconus.

    PubMed

    Spadea, Leopoldo; Paroli, Marino

    2012-01-01

    The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (-6.11 D ± 2.48, range -2.50 to -9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. After a mean 15 ± 6.5 (range 6-24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1-10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was -0.79 ± 2.09 (range +1 to -3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8-8.9) D. All the corneas remained clear (haze < 1). The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus.

  11. TM triple-mode microwave filter

    NASA Astrophysics Data System (ADS)

    Lai, S.-L.; Lin, W.-G.

    1990-12-01

    A novel realization of triple-mode six-pole microwave filters that use only TM modes is presented. The application involves TM triple degeneracies in cylindrical cavities using triple-mode elliptic function filter synthesis. Experimental results are reported.

  12. Deep anterior lamellar keratoplasty: dissection plane with viscoelastic and air can be different.

    PubMed

    Ross, Andrew R; Said, Dalia G; El-Amin, Abdalla; Altaan, Saif; Cabrerizo, Javier; Nubile, Mario; Hogan, Emily; Mastropasqua, Leonardo; Dua, Harminder Singh

    2018-04-03

    To investigate and define the nature of big bubbles (BB) formed by injection of viscoelastic in deep anterior lamellar keratoplasty. Intrastromal injections of 0.1 and 0.3 mL of sodium hyaluronate 1.2% and 0.6% were made into sclera-corneal discs (n = 32) at superficial (anterior-third), midstromal (middle-third) and deep (posterior-third) levels to simulate deep anterior lamellar keratoplasty. Postinjection optical coherence tomograms (OCT) were obtained with the needle in situ. The samples were sectioned and examined histologically. Twelve control samples were injected with air. With superficial injections (n=8) only intrastromal accumulation of viscoelastic was noted. With midstromal injections (n=10) intrastromal accumulation of viscoelastic (n=6) and intrastromal big bubbles (IBB) (n=4) with substantial and variable stromal tissue in the walls were noted. No type 1, type 2 or mixed BB were noted. With deep injections (n=14), type 1 BB (n=4), IBB (n=4) and mixed BB (n=6) were obtained.There was no difference in the results with the two different concentrations of viscoelastic used. With air injection (n=12), 10 type 1 and 1 type 2 BB and 1 mixed BB were obtained. No IBB was noted. BB obtained by injection of viscoelastic and air can be different. The former tends to occur at the site of injection, especially with midstromal injections, takes the form of tissue separation by stretch and tearing and does not cleave in a consistent plane like air. Surgeons should be aware of IBB created by viscodissection and not confuse it for a type1 BB. Intraoperative OCT should help identify IBB. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Simultaneous topography-guided PRK followed by corneal collagen cross-linking after lamellar keratoplasty for keratoconus

    PubMed Central

    Spadea, Leopoldo; Paroli, Marino

    2012-01-01

    Background The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. Methods The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (−6.11 D ± 2.48, range −2.50 to −9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. Results After a mean 15 ± 6.5 (range 6–24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1–10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was −0.79 ± 2.09 (range +1 to −3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8–8.9) D. All the corneas remained clear (haze < 1). Conclusion The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus. PMID:23152658

  14. Triple flames and flame stabilization

    NASA Technical Reports Server (NTRS)

    Broadwell, James E.

    1994-01-01

    It is now well established that when turbulent jet flames are lifted, combustion begins, i.e., the flame is stabilized, at an axial station where the fuel and air are partially premixed. One might expect, therefore, that the beginning of the combustion zone would be a triple flame. Such flames have been described; however, other experiments provide data that are difficult to reconcile with the presence of triple flames. In particular, laser images of CH and OH, marking combustion zones, do not exhibit shapes typical of triple flames, and, more significantly, the lifted flame appears to have a propagation speed that is an order of magnitude higher than the laminar flame speed. The speed of triple flames studied thus far exceeds the laminar value by a factor less than two. The objective of the present task is the resolution of the apparent conflict between the experiments and the triple flame characteristics, and the clarification of the mechanisms controlling flame stability. Being investigated are the resolution achieved in the experiments, the flow field in the neighborhood of the stabilization point, propagation speeds of triple flames, laboratory flame unsteadiness, and the importance of flame ignition limits in the calculation of triple flames that resemble lifted flames.

  15. Quantification of Collagen Ultrastructure after Penetrating Keratoplasty – Implications for Corneal Biomechanics

    PubMed Central

    Gardner, Steven J.; Kamma-Lorger, Christina S.; Hayes, Sally; Nielsen, Kim; Hjortdal, Jesper; Sorensen, Thomas; Terrill, Nicholas J.; Meek, Keith M.

    2013-01-01

    Purpose To quantify long-term changes in stromal collagen ultrastructure following penetrating keratoplasty (PK), and evaluate their possible implications for corneal biomechanics. Methods A pair of 16 mm post-mortem corneo-scleral buttons was obtained from a patient receiving bilateral penetrating keratoplasty 12 (left)/28 (right) years previously. Small-angle x-ray scattering quantified collagen fibril spacing, diameter and spatial order at 0.5 mm or 0.25 mm intervals along linear scans across the graft margin. Corresponding control data was collected from two corneo-scleral buttons with no history of refractive surgery. Wide-angle x-ray scattering quantified collagen fibril orientation at 0.25 mm (horizontal)×0.25 mm (vertical) intervals across both PK specimens. Quantification of orientation changes in the graft margin were verified by equivalent analysis of data from a 13 year post-operative right PK specimen obtained from a second patient in a previous study, and comparison made with new and published data from normal corneas. Results Marked changes to normal fibril alignment, in favour of tangentially oriented collagen, were observed around the entire graft margin in all PK specimens. The total number of meridional fibrils in the wound margin was observed to decrease by up to 40%, with the number of tangentially oriented fibrils increasing by up to 46%. As a result, in some locations the number of fibrils aligned parallel to the wound outnumbered those spanning it by up to five times. Localised increases in fibril spacing and diameter, with an accompanying reduction in matrix order, were also evident. Conclusions Abnormal collagen fibril size and spatial order within the PK graft margin are indicative of incomplete stromal wound remodelling and the long term persistence of fibrotic scar tissue. Lasting changes in collagen fibril orientation in and around PK wounds may alter corneal biomechanics and compromise the integrity of the graft-host interface in the

  16. Orbit Alignment in Triple Stars

    NASA Astrophysics Data System (ADS)

    Tokovinin, Andrei

    2017-08-01

    The statistics of the angle Φ between orbital angular momenta in hierarchical triple systems with known inner visual or astrometric orbits are studied. A correlation between apparent revolution directions proves the partial orbit alignment known from earlier works. The alignment is strong in triples with outer projected separation less than ˜50 au, where the average Φ is about 20^\\circ . In contrast, outer orbits wider than 1000 au are not aligned with the inner orbits. It is established that the orbit alignment decreases with the increasing mass of the primary component. The average eccentricity of inner orbits in well-aligned triples is smaller than in randomly aligned ones. These findings highlight the role of dissipative interactions with gas in defining the orbital architecture of low-mass triple systems. On the other hand, chaotic dynamics apparently played a role in shaping more massive hierarchies. The analysis of projected configurations and triples with known inner and outer orbits indicates that the distribution of Φ is likely bimodal, where 80% of triples have {{Φ }}< 70^\\circ and the remaining ones are randomly aligned.

  17. Genetics Home Reference: triple X syndrome

    MedlinePlus

    ... Twitter Home Health Conditions Triple X syndrome Triple X syndrome Printable PDF Open All Close All Enable ... to view the expand/collapse boxes. Description Triple X syndrome , also called trisomy X or 47,XXX, ...

  18. Atypical Presentation of Iridocorneal Endothelial Syndrome With Band Keratopathy but No Corneal Edema Managed With Descemet Membrane Endothelial Keratoplasty.

    PubMed

    Zygoura, Vasiliki; Lavy, Itay; Verdijk, Robert M; Santander-García, Diana; Baydoun, Lamis; Dapena, Isabel; Melles, Gerrit R J

    2018-04-17

    To report an unusual presentation of iridocorneal endothelial (ICE) syndrome associated with band keratopathy and its management with ethylenediamine-tetraacetic acid (EDTA) chelation and Descemet membrane endothelial keratoplasty (DMEK). A 57-year-old female patient presented with unilateral progressive painless visual impairment, corneal band keratopathy, and morphological corneal endothelial changes without corneal edema or any previous ophthalmic, medical, or family history. Routine specular and confocal microscopy imaging, as well as biomicroscopy, best-corrected visual acuity, and pachymetry measurements were performed before and after the surgical procedures. Histopathologic and immunohistochemical evaluations of the surgically excised diseased DM-endothelium were performed. Superficial epithelial keratectomy with EDTA chelation was performed. After an initial period of a few months of corneal clearance, the patient presented with recurrence of visually significant band keratopathy. After 1 year, she underwent retreatment with superficial epithelial keratectomy and EDTA chelation, followed by DMEK. Histopathologic and immunohistochemical analysis showed ICE syndrome. Two years after DMEK surgery, the cornea was still clear and band keratopathy had not recurred. To the best of our knowledge, this is the first case in the literature that reports the association of ICE syndrome with band keratopathy. As band keratopathy recurred shortly after EDTA chelation, endothelial keratoplasty (DMEK) may be indicated to successfully treat such cases.

  19. Fluorescent in situ hybridization (FISH) on corneal impression cytology specimens (CICS): study of epithelial cell survival after keratoplasty.

    PubMed

    Catanese, Muriel; Popovici, Cornel; Proust, Hélène; Hoffart, Louis; Matonti, Frédéric; Cochereau, Isabelle; Conrath, John; Gabison, Eric E

    2011-02-22

    To assess corneal epithelial cell survival after keratoplasty. Corneal impression cytology (CIC) was performed on sex-mismatched corneal transplants. Fluorescent in situ hybridization (FISH) with sex chromosome-specific probes was performed to identify epithelial cell mosaicism and therefore allocate the donor or recipient origin of the cells. Twenty-four samples of corneal epithelial cells derived from 21 transplanted patients were analyzed. All patients received post-operative treatment using dexamethasone eye drops, with progressive tapering over 18 months, and nine patients also received 2% cyclosporine eye drops. Out of the 24 samples reaching quality criteria, sex mosaicism was found in 13, demonstrating the presence of donor-derived cells at the center of the graft for at least 211 days post keratoplasty. Kaplan-Meier analysis established a median survival of donor corneal epithelial cells of 385 days. Although not statistically significant, the disappearance of donor cells seemed to be delayed and the average number of persistent cells appeared to be greater when 2% cyclosporine was used topically as an additional immunosuppressive therapy. The combination of corneal impressions and FISH analysis is a valuable tool with negligible side effects to investigate the presence of epithelial cell mosaicism in sex-mismatched donor transplants. Epithelial cells survived at the center of the graft with a median survival of more than one year, suggesting slower epithelial turnover than previously described.

  20. Interface quality of different corneal lamellar–cut depths for femtosecond laser–assisted lamellar anterior keratoplasty

    PubMed Central

    Zhang, Chenxing; Bald, Matthew; Tang, Maolong; Li, Yan; Huang, David

    2015-01-01

    PURPOSE To evaluate interface quality of different corneal lamellar–cut depths with the femtosecond laser and determine a feasible range of depth for femtosecond laser–assisted lamellar anterior keratoplasty. SETTING Casey Eye Institute, Portland, Oregon, USA. DESIGN Experimental study. METHODS Full lamellar cuts were made on 20 deepithelialized human cadaver corneas using the femtosecond laser. The cut depth was 17% to 21% (100 μm), 31%, 35%, 38% to 40%, and 45% to 48% of the central stromal thickness. Scanning electron microscopy images of cap and bed surfaces were subjectively graded for ridge and roughness using a scale of 1 to 5 (1 = best). The graft–host match was evaluated by photography and optical coherence tomography in a simulated procedure. RESULTS The ridge score was correlated with the cut depth (P = .0078, R = 0.58) and better correlated with the percentage cut depth (P = .00024, R = 0.73). The shallowest cuts had the least ridges (score 1.25). The 31% cut depth produced significantly less ridges (score 2.15) than deeper cuts. The roughness score ranged from 2.19 to 3.08 for various depths. A simulated procedure using a 100 μm host cut and a 177 μm (31%) graft had a smooth interface and flush anterior junction using an inverted side-cut design. CONCLUSIONS The femtosecond laser produced more ridges in deeper lamellar cuts. A depth setting of 31% stromal thickness might produce adequate surface quality for femtosecond laser–assisted lamellar anterior keratoplasty. The inverted side-cut design produced good edge apposition even when the graft was thicker than the host lamellar–cut depth. PMID:25747165

  1. Penetrating keratoplasty for treatment of corneal protrusion in a great horned owl (Bubo virginianus).

    PubMed

    Andrew, Stacy E; Clippinger, Tracy L; Brooks, Dennis E; Helmick, Kelly E

    2002-09-01

    A young adult great horned owl (Bubo virginianus) was examined following presumed trauma. The owl had soft tissue injury to its left wing as well as corneal protrusion, lens subluxation, and iridodialysis of the right eye. The bird's eye was treated surgically with a large, rectangular penetrating keratoplasty. Following escape from housing, the bird was found with partial wound dehiscence and iris prolapse 12 days post operation. Surgical repair was performed and healing progressed for 14 days, at which time the transplant dehisced and the globe was exenterated. The patient rehabilitated well until escaping from its cage again 4 weeks later, at which time it sustained an open comminuted humeral fracture and was euthanized.

  2. Effects of central corneal thickness on measurement of intra-ocular pressure in keratoconus and post-keratoplasty.

    PubMed

    Patel, S; McLaughlin, J M

    1999-05-01

    To measure and compare central corneal thickness (CT) and intraocular pressure (IOP) in keratoconus and post-keratoplasty subjects and examine the CT-IOP relationship. 22 keratoconus (category I: six female sixteen male, average age 27.0 range 12-47) and 19 post-keratoplasty (category II: ten female nine male average age 34.6 range 16-54) patients without other anterior segment conditions were recruited. Only one, non-contact lens wearing, eye of the patient was included for analysis. Cornea was anaesthetised with non-preserved 0.4% Benoxinate Hydrochloride. Using a randomised approach, CT was measured using a standard ultrasonic pachymeter. IOP was then measured using a standard Goldmann tonometer. At all times the tonometrist remained unaware of the corneal thickness values. The mean (+/- s.d.) values for CT and IOP respectively in the two categories were: (I), 445 (45) mu and 9.8 (2.3) mmHg, (II), 564(44) microns and 15.8 (3.9) mmHg. Differences between I and II for both CT and IOP were significant (t-test, p = 0.01). Within each category, a significant correlation between CT and IOP was not found. Pooling all pairs of data (n = 41) a significant relationship between CT and IOP was detected (r = 0.635, p = 0.0001). The results confirm the hypothesis that an eye with a thicker cornea tends to present with a higher measured IOP. In the management of keratoconus and other corneal surgical procedures, changes in CT will contribute to any apparent changes in measured IOP.

  3. Geodynamical simulation of the RRF triple junction

    NASA Astrophysics Data System (ADS)

    Wang, Z.; Wei, D.; Liu, M.; Shi, Y.; Wang, S.

    2017-12-01

    Triple junction is the point at which three plate boundaries meet. Three plates at the triple junction form a complex geological tectonics, which is a natural laboratory to study the interactions of plates. This work studies a special triple junction, the oceanic transform fault intersects the collinear ridges with different-spreading rates, which is free of influence of ridge-transform faults and nearby hotspots. First, we build 3-D numerical model of this triple junction used to calculate the stead-state velocity and temperature fields resulting from advective and conductive heat transfer. We discuss in detail the influence of the velocity and temperature fields of the triple junction from viscosity, spreading rate of the ridge. The two sides of the oceanic transform fault are different sensitivities to the two factors. And, the influence of the velocity mainly occurs within 200km of the triple junction. Then, we modify the model by adding a ridge-transform fault to above model and directly use the velocity structure of the Macquarie triple junction. The simulation results show that the temperature at both sides of the oceanic transform fault decreases gradually from the triple junction, but the temperature difference between the two sides is a constant about 200°. And, there is little effect of upwelling velocity away from the triple junction 100km. The model results are compared with observational data. The heat flux and thermal topography along the oceanic transform fault of this model are consistent with the observed data of the Macquarie triple junction. The earthquakes are strike slip distributed along the oceanic transform fault. Their depths are also consistent with the zone of maximum shear stress. This work can help us to understand the interactions of plates of triple junctions and help us with the foundation for the future study of triple junctions.

  4. Triple-Crater in Elysium Planitia

    NASA Image and Video Library

    2015-01-22

    This image from NASA Mars Mars Reconnaissance Orbiter shows a triple impact crater in Elysium Planitia near Tartarus Montes, which probably formed when a binary-or even triple-asteroid struck the surface.

  5. Triple Asteroid System Triples Asteroid Observers Interest

    NASA Image and Video Library

    2009-08-06

    NASA Deep Space Network, Goldstone radar images show triple asteroid 1994 CC, which consists of a central object approximately 700 meters 2,300 feet in diameter and two smaller moons that orbit the central body. Animation available at the Photojournal

  6. A Mathematical Model to Predict Endothelial Cell Density Following Penetrating Keratoplasty With Selective Dropout From Graft Failure

    PubMed Central

    Riddlesworth, Tonya D.; Kollman, Craig; Lass, Jonathan H.; Patel, Sanjay V.; Stulting, R. Doyle; Benetz, Beth Ann; Gal, Robin L.; Beck, Roy W.

    2014-01-01

    Purpose. We constructed several mathematical models that predict endothelial cell density (ECD) for patients after penetrating keratoplasty (PK) for a moderate-risk condition (principally Fuchs' dystrophy or pseudophakic/aphakic corneal edema). Methods. In a subset (n = 591) of Cornea Donor Study participants, postoperative ECD was determined by a central reading center. Various statistical models were considered to estimate the ECD trend longitudinally over 10 years of follow-up. A biexponential model with and without a logarithm transformation was fit using the Gauss-Newton nonlinear least squares algorithm. To account for correlated data, a log-polynomial model was fit using the restricted maximum likelihood method. A sensitivity analysis for the potential bias due to selective dropout was performed using Bayesian analysis techniques. Results. The three models using a logarithm transformation yield similar trends, whereas the model without the transform predicts higher ECD values. The adjustment for selective dropout turns out to be negligible. However, this is possibly due to the relatively low rate of graft failure in this cohort (19% at 10 years). Fuchs' dystrophy and pseudophakic/aphakic corneal edema (PACE) patients had similar ECD decay curves, with the PACE group having slightly higher cell densities by 10 years. Conclusions. Endothelial cell loss after PK can be modeled via a log-polynomial model, which accounts for the correlated data from repeated measures on the same subject. This model is not significantly affected by the selective dropout due to graft failure. Our findings warrant further study on how this may extend to ECD following endothelial keratoplasty. PMID:25425307

  7. NIM Realization of the Gallium Triple Point

    NASA Astrophysics Data System (ADS)

    Xiaoke, Yan; Ping, Qiu; Yuning, Duan; Yongmei, Qu

    2003-09-01

    In the last three years (1999 to 2001), the gallium triple-point cell has been successfully developed, and much corresponding research has been carried out at the National Institute of Metrology (NIM), Beijing, China. This paper presents the cell design, apparatus and procedure for realizing the gallium triple point, and presents studies on the different freezing methods. The reproducibility is 0.03 mK, and the expanded uncertainty of realization of the gallium triple point is evaluated to be 0.17 mK (p=0.99, k=2.9). Also, the reproducibility of the gallium triple point was compared with that of the triple point of water.

  8. Air pressure changes in the creation and bursting of the type-1 big bubble in deep anterior lamellar keratoplasty: an ex vivo study.

    PubMed

    AlTaan, S L; Mohammed, I; Said, D G; Dua, H S

    2018-01-01

    PurposeTo measure the pressure and volume of air required to create a big bubble (BB) in simulated deep anterior lamellar keratoplasty (DALK) in donor eyes and ascertain the bursting pressure of the BB.Patients and methodsTwenty-two human sclera-corneal discs were used. Air was injected into the corneal stroma to create a BB and the pressure measured by means of a pressure converter attached to the system via a side port. A special clamp was designed to prevent air leak from the periphery of the discs. The pressure at which air emerged in the corneal tissue; the bursting pressure measured after advancing the needle into the bubble cavity and injecting more air; the volume of air required to create a BB and the volume of the BB were ascertained.ResultsType-1 BB were achieved in 19 and type-2 BB in 3 eyes. The maximum pressure reached to create a BB was 96.25+/- 21.61 kpa; the mean type-1 intrabubble pressure was 10.16 +/- 3.65 kpa. The mean bursting pressure of a type-1 BB was 66.65 +/- 18.65 kpa, while that of a type-2 BB was 14.77 +/- 2.44 kpa. The volume of air required to create a type-1 BB was 0.54 ml and the volume of a type-1 BB was consistently 0.1 ml.ConclusionsDua's layer baring DALK can withstand high intraoperative pressures compared to Descemet's membrane baring DALK. The study suggests that it could be safe to undertake procedures such as DALK-triple with a type-1 BB but not with a type-2 BB.

  9. Counting Primitive Pythagorean Triples

    ERIC Educational Resources Information Center

    Ayoub, Ayoub B.

    2005-01-01

    A triple (x,y,z) of natural numbers is called a Primitive Pythagorean Triple (PPT) if it satisfies two conditions: (1) x[squared] + y[squared] = z[squared]; and (2) x, y, and z have no common factor other than one. All the PPT's are given by the parametric equations: (1) x = m[squared] - n[squared]; (2) y = 2mn; and (3) z = m[squared] +…

  10. Use of a "small-bubble technique" to increase the success of Anwar's "big-bubble technique" for deep lamellar keratoplasty with complete baring of Descemet's membrane.

    PubMed

    Parthasarathy, Anand; Por, Yong Ming; Tan, Donald T H

    2007-10-01

    To describe a quick and simple "small-bubble" technique to immediately determine the success of attaining complete Descemet's membrane (DM) separation from corneal stroma through Anwar's "big-bubble" technique of deep anterior lamellar keratoplasty (DALK) for complete stromal removal. A partial trephination was followed by a lamellar dissection of the anterior stroma. Deep stromal air injection was then attempted to achieve the big bubble to help separate the stroma from the DM. To confirm that a big bubble had been achieved, a small air bubble was injected into the anterior chamber (AC) through a limbal paracentesis. If the small bubble is then seen at the corneal periphery, it confirms that the big-bubble separation of DM was successful because the convex nature of the bubble will cause it to protrude posteriorly, forcing the small AC bubble to the periphery. If the small AC bubble is not seen in the corneal periphery, this means that it is present in the centre, beneath the opaque corneal stroma, and therefore the big bubble has not been achieved. We used the small-bubble technique to confirm the presence of the big bubble in three (one keratoconus, one interstitial keratitis and one dense corneal scar) out of 41 patients who underwent DALK. The small-bubble technique confirmed that the big bubble was achieved in the eye of all three patients. Complete stromal removal with baring of the DM was achieved, and postoperatively all three eyes achieved best corrected vision of 6/6. The small-bubble technique can be a useful surgical tool for corneal surgeons attempting lamellar keratoplasty using the big-bubble technique. It helps in confirming the separation of DM from the deep stroma, which is important in achieving total stromal replacement. It will help to make the transition to lamellar keratoplasty smoother, enhance corneal graft success and improve visual outcomes in patients.

  11. Da Vinci Xi Robot–Assisted Penetrating Keratoplasty

    PubMed Central

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-01-01

    Purpose This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Methods Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Results Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5–61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. Conclusions We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Translational Relevance Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use. PMID:28660096

  12. Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.

    PubMed

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-06-01

    This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.

  13. Standardizing Descemet Membrane Endothelial Keratoplasty Graft Preparation Method in the Eye Bank-Experience of 527 Descemet Membrane Endothelial Keratoplasty Tissues.

    PubMed

    Parekh, Mohit; Baruzzo, Mattia; Favaro, Elisa; Borroni, Davide; Ferrari, Stefano; Ponzin, Diego; Ruzza, Alessandro

    2017-12-01

    To share the experience and provide a standardized protocol for Descemet membrane endothelial keratoplasty (DMEK) graft preparation. A retrospective study based on 527 prestripped DMEK tissues that were prepared between 2014 and 2017. The experience of using different instruments and techniques has been described, and a standardized technique for preparing DMEK grafts has been identified. The tissues in general were prepared by superficially tapping the endothelial side with a Moria trephine (9.5 mm diameter). The plane of cleavage was identified using a cleavage hook, and the DMEK graft was deadhered from the trephined site throughout the circumference for ease of excising the graft. The DMEK graft was peeled using either one or multiple quadrant methods depending on the challenges faced during excision. The graft was finally marked with the letter "F" to identify the orientation during surgery. Data on endothelial cell loss (ECL) and challenging cases were observed, monitored, and recorded during this period. Less than 1 percent trypan blue-positive cells with tissue wastage of <6% was observed during the study period. Our standardized stripping technique has resulted in an overall ECL of 4.6%. Marking Descemet membrane showed 0.5% cell mortality. Standardizing DMEK technique using specific tools and simple techniques would help new surgeons to decide the instruments and improve their tissue preparation skills also in challenging cases such as previous cataract incisions or horseshoe-shaped tears, further reducing ECL or tissue wastage.

  14. Triple dye plus rubbing alcohol versus triple dye alone for umbilical cord care.

    PubMed

    Suliman, Alawia K; Watts, Heidi; Beiler, Jessica; King, Tonya S; Khan, Sana; Carnuccio, Marybeth; Paul, Ian M

    2010-01-01

    Current practices for umbilical cord care vary across centers, but the evidence regarding these practices and their impact on cord separation, complications, and health care use are limited. The objective of this study was to compare the effect of triple dye alone (brilliant green, crystal violet, and proflavine hemisulfate) versus triple dye plus rubbing alcohol (isopropyl alcohol) twice daily on time to umbilical cord separation, complications, and health care use. For the 90 newborns who completed the study, there were no significant differences between treatment groups for time to cord separation, cord-related morbidities, or cord-related urgent care. Based on these study results, there does not appear to be significant benefit to the addition of twice daily applications of rubbing alcohol to neonatal umbilical cords following triple dye treatment after birth.

  15. Donor cornea preparation in partial big bubble deep anterior lamellar keratoplasty.

    PubMed

    Lim, Li; Lim, Samuel Wen Yan

    2014-01-01

    The purpose of this paper is to describe a technique of donor cornea preparation to ensure good graft-host apposition in incomplete big bubble deep anterior lamellar keratoplasty. Following a partial-thickness trephination, manual dissection and excision of corneal stroma was performed. Anwar's big-bubble technique involving a deep stromal air injection was then initiated. However, the big bubble could not extend to the trephination edge and the peripheral residual corneal stroma could not be removed. Donor cornea preparation involving trimming of the posterior lip of the corneal button was then performed and good graft-host apposition was obtained without graft over-ride. We performed peripheral donor cornea trimming prior to allograft placement in order to ensure good graft-host apposition. Postoperatively, best-corrected visual acuity in both eyes was 6/7.5. Donor cornea preparation involving trimming of the posterior lip of the corneal button is a useful technique in instances where the big bubble does not extend to the trephination edge and ensures good graft-host apposition.

  16. Teaching Triple Science: GCSE Chemistry

    ERIC Educational Resources Information Center

    Learning and Skills Network (NJ3), 2007

    2007-01-01

    The Department for Children, Schools and Families (DCSF) has contracted with the Learning and Skills Network to support awareness and take-up of Triple Science GCSEs through the Triple Science Support Programme. This publication provides an introduction to teaching and learning approaches for the extension topics within GCSE Chemistry. It…

  17. Teaching Triple Science: GCSE Biology

    ERIC Educational Resources Information Center

    Learning and Skills Network (NJ3), 2007

    2007-01-01

    The Department for Children, Schools and Families (DCSF) has contracted with the Learning and Skills Network to support awareness and take-up of Triple Science GCSEs through the Triple Science Support Programme. This publication provides an introduction to teaching and learning approaches for the extension topics within GCSE Biology. It highlights…

  18. Electrospun nanofibrous SF/P(LLA-CL) membrane: a potential substratum for endothelial keratoplasty.

    PubMed

    Chen, Junzhao; Yan, Chenxi; Zhu, Mengyu; Yao, Qinke; Shao, Chunyi; Lu, Wenjuan; Wang, Jing; Mo, Xiumei; Gu, Ping; Fu, Yao; Fan, Xianqun

    2015-01-01

    Cornea transplant technology has progressed markedly in recent decades, allowing surgeons to replace diseased corneal endothelium by a thin lamellar structure. A thin, transparent, biocompatible, tissue-engineered substratum with corneal endothelial cells for endothelial keratoplasty is currently of interest. Electrospinning a nanofibrous structure can simulate the extracellular matrix and have beneficial effects for cell culture. Silk fibroin (SF) has good biocompatibility but poor mechanical properties, while poly(L-lactic acid-co-ε-caprolactone) (P(LLA-CL)) has good mechanical properties but poor biocompatibility. Blending SF with P(LLA-CL) can maintain the advantages of both these materials and overcome their disadvantages. Blended electrospun nanofibrous membranes may be suitable for regeneration of the corneal endothelium. The aim of this study was to produce a tissue-engineered construct suitable for endothelial keratoplasty. Five scaffolds containing different SF:P(LLA-CL) blended ratios (100:0, 75:25, 50:50, 25:75, 0:100) were manufactured. A human corneal endothelial (B4G12) cell line was cultured on the membranes. Light transmission, speed of cell adherence, cell viability (live-dead test), cell proliferation (Ki-67, BrdU staining), and cell monolayer formation were detected on membranes with the different blended ratios, and expression of some functional genes was also detected by real-time polymerase chain reaction. Different blended ratios of scaffolds had different light transmittance properties. The 25:75 blended ratio membrane had the best transmittance among these scaffolds. All electrospun nanofibrous membranes showed improved speed of cell adherence when compared with the control group, especially when the P(LLA-CL) ratio increased. The 25:75 blended ratio membranes also had the highest cell proliferation. B4G12 cells could form a monolayer on all scaffolds, and most functional genes were also stably expressed on all scaffolds. Only two genes

  19. Recovery and normalization of triple coincidences in PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.

    2015-03-15

    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose amore » simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with

  20. Recovery and normalization of triple coincidences in PET.

    PubMed

    Lage, Eduardo; Parot, Vicente; Moore, Stephen C; Sitek, Arkadiusz; Udías, Jose M; Dave, Shivang R; Park, Mi-Ae; Vaquero, Juan J; Herraiz, Joaquin L

    2015-03-01

    Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. To recover triple coincidences, the authors' method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. The addition of triple-coincidence events with the authors' method increased peak

  1. Triple effect absorption cycles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, D.C.; Potnis, S.V.; Tang, J.

    1996-12-31

    Triple effect absorption chillers can achieve 50% COP improvement over double-effect systems. However, to translate this potential into cost-effective hardware, the most promising embodiments must be identified. In this study, 12 generic triple effect cycles and 76 possible hermetic loop arrangements of those 12 generic cycles were identified. The generic triple effect cycles were screened based on their pressure and solubility field requirements, generic COPs, risk involved in the component design, and number of components in a high corrosive environment. This screening identified four promising arrangements: Alkitrate Topping cycle, Pressure Staged Envelope cycle, High Pressure Overlap cycle, and Dual Loopmore » cycle. All of these arrangements have a very high COP ({approximately} 1.8), however the development risk and cost involved is different for each arrangement. Therefore, the selection of a particular arrangement will depend upon the specific situation under consideration.« less

  2. Examining Primary Healthcare Performance through a Triple Aim Lens.

    PubMed

    Ryan, Bridget L; Brown, Judith Belle; Glazier, Richard H; Hutchison, Brian

    2016-02-01

    This study sought to apply a Triple Aim framework to the measurement and evaluation of primary healthcare (PHC) team performance. Triple Aim components were populated with 10 dimensions derived from survey and health administrative data for 17 Family Health Teams (FHTs) in Ontario, Canada. Bivariate analyses and rankings of sites examined the relationships among dimensions and among Triple Aim components. Readily available measures to fully populate the Triple Aim framework were lacking in FHTs. Within sites, there was little consistency in performance across the Triple Aim components (health, patient experience and cost). More and better measures are needed that can be readily used to examine the Triple Aim performance in PHC teams. FHTs, in this study, are partially achieving Triple Aim goals; however, there was a lack of consistency in performance. It is essential to collect appropriate measures and attend to performance across all components of the Triple Aim. Copyright © 2016 Longwoods Publishing.

  3. Examining Primary Healthcare Performance through a Triple Aim Lens

    PubMed Central

    Ryan, Bridget L.; Brown, Judith Belle; Glazier, Richard H.; Hutchison, Brian

    2016-01-01

    Purpose: This study sought to apply a Triple Aim framework to the measurement and evaluation of primary healthcare (PHC) team performance. Methods: Triple Aim components were populated with 10 dimensions derived from survey and health administrative data for 17 Family Health Teams (FHTs) in Ontario, Canada. Bivariate analyses and rankings of sites examined the relationships among dimensions and among Triple Aim components. Results: Readily available measures to fully populate the Triple Aim framework were lacking in FHTs. Within sites, there was little consistency in performance across the Triple Aim components (health, patient experience and cost). Conclusions: More and better measures are needed that can be readily used to examine the Triple Aim performance in PHC teams. FHTs, in this study, are partially achieving Triple Aim goals; however, there was a lack of consistency in performance. It is essential to collect appropriate measures and attend to performance across all components of the Triple Aim. PMID:27027790

  4. Laser speckle strain and deformation sensor using linear array image cross-correlation method for specifically arranged triple-beam triple-camera configuration

    NASA Technical Reports Server (NTRS)

    Sarrafzadeh-Khoee, Adel K. (Inventor)

    2000-01-01

    The invention provides a method of triple-beam and triple-sensor in a laser speckle strain/deformation measurement system. The triple-beam/triple-camera configuration combined with sequential timing of laser beam shutters is capable of providing indications of surface strain and structure deformations. The strain and deformation quantities, the four variables of surface strain, in-plane displacement, out-of-plane displacement and tilt, are determined in closed form solutions.

  5. Density of Primitive Pythagorean Triples

    ERIC Educational Resources Information Center

    Killen, Duncan A.

    2004-01-01

    Based on the properties of a Primitive Pythagorean Triple (PPT), a computer program was written to generate, print, and count all PPTs greater than or equal to I[subscript x], where I[subscript x] is an arbitrarily chosen integer. The Density of Primitive Pythagorean Triples may be defined as the ratio of the number of PPTs whose hypotenuse is…

  6. ENDOTHELIAL KERATOPLASTY: CLINICAL OUTCOMES IN THE TWO YEARS FOLLOWING DEEP LAMELLAR ENDOTHELIAL KERATOPLASTY (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    Terry, Mark A.

    2007-01-01

    Purpose To evaluate the clinical outcome of small-incision, deep lamellar endothelial keratoplasty (DLEK) for the treatment of endothelial dysfunction. Methods A prospective series of 79 eyes that underwent DLEK by a single surgeon was evaluated. Best spectacle-corrected visual acuity (BSCVA), refractive astigmatism, and central endothelial cell density (ECD) were measured preoperatively and at 6, 12, and 24 months. Results Data was available on 78 eyes (99%) at 6 months, 77 eyes (97%) at 1 year, and 79 eyes (100%) at 2 years. Mean BSCVA preoperatively of 20/71 improved to 20/42 by 6 months and remained stable. Eliminating eyes with known retinal disease, BSCVA of 20/40 or better was present in 60% (40 of 67) of eyes at 6 months, 74% (49 of 66) of eyes at 1 year, and 79% (53 of 68) of eyes at 2 years. Refractive astigmatism preoperatively was .91 ±.78 diopters and was unchanged by surgery over time with results at 6 months of 1.11 ±.76 (P = .052, power = .43), 1 year 1.04 ±.80 (P =.287, power = .06), and 2 years 1.10 ±.70 (P =.467, power = .22). The mean donor ECD preoperatively was 2819 ± 225 (2389 to 3385) cells/mm2, and this decreased by 26% at 6 months (2095 ± 380) (1097 to 2920) (P = .0001; 95% confidence interval [CI] = 643–809), 3% fewer at 1 year (2009 ± 393) (612 to 2723) (P = .054, power = .5), and 17% fewer at 2 years (1536 ± 547) (500 to 2546) (P < .001, 95% CI = 368–585). Complications included one primary graft failure and 4 dislocations into the anterior chamber. Conclusions DLEK provides improved vision and minimal refractive astigmatic change, but progressive ECD decrease over time is of concern. PMID:18427629

  7. Vectorized data acquisition and fast triple-correlation integrals for Fluorescence Triple Correlation Spectroscopy

    PubMed Central

    Ridgeway, William K; Millar, David P; Williamson, James R

    2013-01-01

    Fluorescence Correlation Spectroscopy (FCS) is widely used to quantitate reaction rates and concentrations of molecules in vitro and in vivo. We recently reported Fluorescence Triple Correlation Spectroscopy (F3CS), which correlates three signals together instead of two. F3CS can analyze the stoichiometries of complex mixtures and detect irreversible processes by identifying time-reversal asymmetries. Here we report the computational developments that were required for the realization of F3CS and present the results as the Triple Correlation Toolbox suite of programs. Triple Correlation Toolbox is a complete data analysis pipeline capable of acquiring, correlating and fitting large data sets. Each segment of the pipeline handles error estimates for accurate error-weighted global fitting. Data acquisition was accelerated with a combination of off-the-shelf counter-timer chips and vectorized operations on 128-bit registers. This allows desktop computers with inexpensive data acquisition cards to acquire hours of multiple-channel data with sub-microsecond time resolution. Off-line correlation integrals were implemented as a two delay time multiple-tau scheme that scales efficiently with multiple processors and provides an unprecedented view of linked dynamics. Global fitting routines are provided to fit FCS and F3CS data to models containing up to ten species. Triple Correlation Toolbox is a complete package that enables F3CS to be performed on existing microscopes. PMID:23525193

  8. Thermodynamics of a pure substance at the triple point

    NASA Astrophysics Data System (ADS)

    Velasco, S.; Fernández-Pineda, C.

    2007-12-01

    A thermodynamic study of a pure substance at the triple point is presented. In particular, we show that the mass fractions of the phases coexisting at the triple point obey lever rules in the specific entropy-specific volume diagram, and the relative changes in the mass fractions present in each phase along reversible isochoric and adiabatic processes of a pure substance at the triple point are governed by the relative sizes of the segments of the triple-point line in the pressure-specific volume diagram and in the temperature-specific entropy diagram. Applications to the ordinary triple point of water and to the triple point of Al2SiO5 polymorphs are presented.

  9. Arcuate keratotomy on post-keratoplasty astigmatism is unpredictable and frequently needs repeat procedures to increase its success rate.

    PubMed

    Bayramlar, Huseyin; Karadag, Remzi; Cakici, Ozgur; Ozsoy, Isilay

    2016-06-01

    To evaluate the effectiveness and predictability of arcuate keratotomy (AK) for post-keratoplasty astigmatism and to present the complications and rate of repeat procedures. Sixteen eyes from 14 patients were included. Paired 70-80° arc length AKs centred on the steep axis were carried out 0.5 mm within the graft-host junction. The depth of the AKs was set at approximately 80-90% of the depth of the cornea, based on a topographic pachymeter at the incision location. The outcome measures included preoperative and postoperative topographic astigmatism, uncorrected and corrected visual acuity, surgical complications and repeat procedures. In 12 of the 16 eyes (75%), at least one additional surgical procedure was required to obtain the desired result: suturing for overcorrection or wound gape in six eyes (38%), lengthening of the incisions for undercorrection in four eyes (25%) and additional AKs for marked astigmatic axis displacement in three eyes (19%). The mean preoperative astigmatism was 10.45±3.82 dioptres (D); the postoperative astigmatism at the last visit was 2.99±1.14 D (in a mean follow-up of 17.6±5.55 months). The efficacy index was 0.83 and the safety index was 1.68. In treatment of post-keratoplasty astigmatism, AK does not have a good predictability. Additional procedures such as lengthening of the AK incisions for undercorrection or using compression sutures for overcorrection with significantly gaping wounds are frequently required to improve the final outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Triple products of Eisenstein series

    NASA Astrophysics Data System (ADS)

    Venkatesh, Anil

    In this thesis, we construct a Massey triple product on the Deligne cohomology of the modular curve with coefficients in symmetric powers of the standard representation of the modular group. This result is obtained by constructing a Massey triple product on the extension groups in the category of admissible variations of mixed Hodge structure over the modular curve, which induces the desired construction on Deligne cohomology. The result extends Brown's construction of the cup product on Deligne cohomology to a higher cohomological product. Massey triple products on Deligne cohomology have been previously investigated by Deninger, who considered Deligne cohomology with trivial real coefficients. By working over the reals, Deninger was able to compute cohomology exclusively with differential forms. In this work, Deligne cohomology is studied over the rationals, which introduces an obstruction to applying Deninger's results. The obstruction arises from the fact that the integration map from the de Rham complex to the Eilenberg-MacLane complex of the modular group is not an algebra homomorphism. We compute the correction terms of the integration map as regularized iterated integrals of Eisenstein series, and show that these integrals arise in the cup product and Massey triple product on Deligne cohomology.

  11. Stimulated penetrating keratoplasty using real-time virtual intraoperative surgical optical coherence tomography

    PubMed Central

    Lee, Changho; Kim, Kyungun; Han, Seunghoon; Kim, Sehui; Lee, Jun Hoon; Kim, Hong kyun; Kim, Chulhong; Jung, Woonggyu; Kim, Jeehyun

    2014-01-01

    Abstract. An intraoperative surgical microscope is an essential tool in a neuro- or ophthalmological surgical environment. Yet, it has an inherent limitation to classify subsurface information because it only provides the surface images. To compensate for and assist in this problem, combining the surgical microscope with optical coherence tomography (OCT) has been adapted. We developed a real-time virtual intraoperative surgical OCT (VISOCT) system by adapting a spectral-domain OCT scanner with a commercial surgical microscope. Thanks to our custom-made beam splitting and image display subsystems, the OCT images and microscopic images are simultaneously visualized through an ocular lens or the eyepiece of the microscope. This improvement helps surgeons to focus on the operation without distraction to view OCT images on another separate display. Moreover, displaying the OCT live images on the eyepiece helps surgeon’s depth perception during the surgeries. Finally, we successfully processed stimulated penetrating keratoplasty in live rabbits. We believe that these technical achievements are crucial to enhance the usability of the VISOCT system in a real surgical operating condition. PMID:24604471

  12. [Period-tripling in Multiscale Physical and Biological Events].

    PubMed

    Bondar, A T; Fedorov, M V; Kolombet, V A

    2015-01-01

    A recent paper by S.J. Puetz et al. (Chaos, Solitons -& Fractals, v. 62-63, p. 55, 2014) described a fundamental period-tripled model. It involves periods of different astronomical (quasars, Sun), geophysical (geomagnetic, climatic, volcanic) and some biological processes. This work contains statistics for sixteen pairs of a period-tripled sequence. These periods range from -50 years to 1.5 billion years and no signs of the timescale limitations are found. We believe that the universal scope of the fundamental period-tripled model can be used for the development of new methodology of research data analysis: the main idea is that the spectrum of the periods of the studied event should be tested for the similarity with the spectrum of fundamental period-tripling pattern (because of the fundamental nature of the period-tripled model). Using this method, in this study we complement an already described period-tripled model with periods of human memory performance ranging from one minute to one month also adding seven relevant periods/frequencies of the period-tripled model in the range of human hearing. We make a conclusion that these characteristic frequencies may form the basis for music and singing phenomena. The new methodology is particularly appropriate for being applied in medicine and engineering.

  13. Warps, grids and curvature in triple vector bundles

    NASA Astrophysics Data System (ADS)

    Flari, Magdalini K.; Mackenzie, Kirill

    2018-06-01

    A triple vector bundle is a cube of vector bundle structures which commute in the (strict) categorical sense. A grid in a triple vector bundle is a collection of sections of each bundle structure with certain linearity properties. A grid provides two routes around each face of the triple vector bundle, and six routes from the base manifold to the total manifold; the warps measure the lack of commutativity of these routes. In this paper we first prove that the sum of the warps in a triple vector bundle is zero. The proof we give is intrinsic and, we believe, clearer than the proof using decompositions given earlier by one of us. We apply this result to the triple tangent bundle T^3M of a manifold and deduce (as earlier) the Jacobi identity. We further apply the result to the triple vector bundle T^2A for a vector bundle A using a connection in A to define a grid in T^2A . In this case the curvature emerges from the warp theorem.

  14. Quantification and Patterns of Endothelial Cell Loss Due to Eye Bank Preparation and Injector Method in Descemet Membrane Endothelial Keratoplasty Tissues.

    PubMed

    Schallhorn, Julie M; Holiman, Jeffrey D; Stoeger, Christopher G; Chamberlain, Winston

    2016-03-01

    To evaluate endothelial cell damage after eye bank preparation and passage through 1 of 2 different injectors for Descemet membrane endothelial keratoplasty grafts. Eighteen Descemet membrane endothelial keratoplasty grafts were prepared by Lions VisionGift with the standard partial prepeel technique and placement of an S-stamp for orientation. The grafts were randomly assigned to injection with either a glass-modified Jones tube injector (Gunther Weiss Scientific Glass) or a closed-system intraocular lens injector (Viscoject 2.2; Medicel). After injection, the grafts were stained with the vital fluorescent dye Calcein AM and digitally imaged. The percentage of cell loss was calculated by measuring the area of nonfluorescent pixels and dividing it by the total graft area pixels. Grafts injected using the modified Jones tube injector had an overall cell loss of 27% ± 5% [95% confidence interval, 21%-35%]. Grafts injected using the closed-system intraocular lens injector had a cell loss of 32% ± 8% (95% confidence interval, 21%-45%). This difference was not statistically significant (P = 0.3). Several damage patterns including damage due to S-stamp placement were observed, but they did not correlate with injector type. In this in vitro study, there was no difference in the cell loss associated with the injector method. Grafts in both groups sustained significant cell loss and displayed evidence of graft preparation and S-stamp placement. Improvement in graft preparation and injection methods may improve cell retention.

  15. Impact of eye bank lamellar tissue cutting for endothelial keratoplasty on bacterial and fungal corneoscleral donor rim cultures after corneal transplantation.

    PubMed

    Rauen, Matthew P; Goins, Kenneth M; Sutphin, John E; Kitzmann, Anna S; Schmidt, Gregory A; Wagoner, Michael D

    2012-04-01

    To determine if the lamellar cut of donor tissue for endothelial keratoplasty (EK) by an eye bank facility is associated with a change in the prevalence of positive bacterial or fungal donor rim cultures after corneal transplantation. A retrospective review was conducted of bacterial and fungal cultures of donor rims used for corneal transplantation at a tertiary eye care center from January 1, 2003, to December 31, 2008, with tissue provided by a single eye bank. The cases were divided into 2 groups. Group 1 ("no-cut") included keratoplasty procedures in which a lamellar cut was not performed. Group 2 ("precut") included EK procedures in which a 4-hour period of prewarming of tissue followed by a lamellar cut was performed in the eye bank before tissue delivery to the operating surgeon. There were 351 donor rim cultures in group 1 and 278 in group 2. Bacterial cultures were positive in 30 donor rims (8.5%) in group 1 and 13 (4.7%) in group 2 (P = 0.058). Positive bacterial cultures were not associated with any postoperative infections. Fungal cultures were positive in 8 donor rims (2.3%) in group 1 and 7 (2.5%) in group 2 (P = 1.0). Positive fungal cultures were associated with 2 cases (13.3%) of postoperative fungal infections. Corneal donor tissue can be precut for EK by trained eye bank personnel without an increased risk of bacterial or fungal contamination.

  16. The effects of complex chemistry on triple flames

    NASA Technical Reports Server (NTRS)

    Echekki, T.; Chen, J. H.

    1996-01-01

    The structure, ignition, and stabilization mechanisms for a methanol (CH3OH)-air triple flame are studied using Direct Numerical Simulations (DNS). The methanol (CH3OH)-air triple flame is found to burn with an asymmetric shape due to the different chemical and transport processes characterizing the mixture. The excess fuel, methanol (CH3OH), on the rich premixed flame branch is replaced by more stable fuels CO and H2, which burn at the diffusion flame. On the lean premixed flame side, a higher concentration of O2 leaks through to the diffusion flame. The general structure of the triple point features the contribution of both differential diffusion of radicals and heat. A mixture fraction-temperature phase plane description of the triple flame structure is proposed to highlight some interesting features in partially premixed combustion. The effects of differential diffusion at the triple point add to the contribution of hydrodynamic effects in the stabilization of the triple flame. Differential diffusion effects are measured using two methods: a direct computation using diffusion velocities and an indirect computation based on the difference between the normalized mixture fractions of C and H. The mixture fraction approach does not clearly identify the effects of differential diffusion, in particular at the curved triple point, because of ambiguities in the contribution of carbon and hydrogen atoms' carrying species.

  17. Cristoforetti packing TripleLux-A experiment

    NASA Image and Video Library

    2015-05-08

    ISS043E181043 (05/08/2015) --- ESA (European Space Agency) astronaut Samantha Cristoforetti prepares the TripleLux-A experiment for return on SpaceX’s Dragon cargo craft. TripleLux-A is investigating immune suppression in space as understanding such risks is essential in maintaining the health and performance of crew members during long-duration missions.

  18. Continuous-Variable Triple-Photon States Quantum Entanglement

    NASA Astrophysics Data System (ADS)

    González, E. A. Rojas; Borne, A.; Boulanger, B.; Levenson, J. A.; Bencheikh, K.

    2018-01-01

    We investigate the quantum entanglement of the three modes associated with the three-photon states obtained by triple-photon generation in a phase-matched third-order nonlinear optical interaction. Although the second-order processes have been extensively dealt with, there is no direct analogy between the second and third-order mechanisms. We show, for example, the absence of quantum entanglement between the quadratures of the three modes in the case of spontaneous parametric triple-photon generation. However, we show robust, seeding-dependent, genuine triple-photon entanglement in the fully seeded case.

  19. Continuous-Variable Triple-Photon States Quantum Entanglement.

    PubMed

    González, E A Rojas; Borne, A; Boulanger, B; Levenson, J A; Bencheikh, K

    2018-01-26

    We investigate the quantum entanglement of the three modes associated with the three-photon states obtained by triple-photon generation in a phase-matched third-order nonlinear optical interaction. Although the second-order processes have been extensively dealt with, there is no direct analogy between the second and third-order mechanisms. We show, for example, the absence of quantum entanglement between the quadratures of the three modes in the case of spontaneous parametric triple-photon generation. However, we show robust, seeding-dependent, genuine triple-photon entanglement in the fully seeded case.

  20. Graft biomechanical properties after penetrating keratoplasty in keratoconus.

    PubMed

    Feizi, Sepehr; Einollahi, Bahram; Yazdani, Shahin; Hashemloo, Ali

    2012-08-01

    To measure corneal graft biomechanical properties after penetrating keratoplasty (PKP) in a group of keratoconic eyes using the ocular response analyzer (ORA) and to evaluate the relationship between donor size, donor-recipient disparity and central graft thickness (CGT), and ORA parameters. This cross-sectional study was conducted on 34 eyes of 34 keratoconus patients who had undergone PKP. Corneal hysteresis (CH), corneal resistance factor (CRF), and cornea-compensated intraocular pressure were measured at least 6 months after complete suture removal. Two groups of donor-recipient disparity (0.25 vs. 0.50 mm) were compared using the independent t test. Multivariate regression analysis was used to investigate the correlation of donor trephine size and CGT with ORA parameters. Factors influencing intraocular pressure measured with the Goldmann applanation tonometer (IOP GAT) after PKP were determined using multiple regression analysis. Mean patient age and follow-up period were 29.6 ± 6.2 years and 82.4 ± 59.6 months, respectively. Mean CGT, CH, and CRF were 564.7 ± 36.9 μm, 10.1 ± 2.1 mm Hg, and 10.0 ± 2.3 mm Hg, respectively. CH and CRF had a significant positive correlation with donor trephine size and CGT. Significantly greater values of CH and CRF were observed in the 0.5-mm disparity group compared with the 0.25-mm disparity group. Among the studied parameters, only CH, CRF, and cornea-compensated intraocular pressure had a significant positive correlation with IOP GAT. Graft biomechanics seem to be closer to normal values with larger grafts and greater donor-recipient disparity. These metrics had a significant correlation with IOP GAT after PKP.

  1. Comparison of femtosecond laser-assisted descemetic and predescemetic lamellar keratoplasty for keratoconus.

    PubMed

    Lu, Yan; Grisolia, Ana Beatriz Diniz; Ge, Yi-Rui; Xue, Chun-Yan; Cao, Qian; Yang, Li-Ping; Huang, Zhen-Ping

    2017-01-01

    The purpose of this study is to compare the outcomes following femtosecond laser-assisted deep anterior lamellar keratoplasty (DALK) with 75% of stromal dissection (predescemetic group) and femtosecond laser-assisted DALK using big-bubble technique with total stromal resection (descemetic group) for the treatment of keratoconus. Twenty eyes of 17 patients with keratoconus were studied. There were 10 eyes of 9 patients in predescemetic group and 10 eyes of 8 patients in descemetic group. The postoperative best-corrected visual acuity (BCVA), manifest refraction, keratometry, endothelial cell density (ECD), and central corneal thickness (CCT) were analyzed. All surgeries were performed uneventfully. At 1 year after surgery, the BCVA, corneal astigmatism, keratometry, CCT, and ECD between two groups were not statistically significant (all P > 0.05). However, the mean manifest refraction was -9.43 ± 7.44 diopter (D) and -1.03 ± 1.13D in predescemetic and descemetic groups, respectively, which was statistically significant between two groups (P < 0.05). The results of BCVA and corneal astigmatism, keratometry, ECD, and CCT were comparable between two groups. However, the mean postoperative manifest refraction was lower in descemetic group.

  2. The minimal carcinoma triple stain is superior to commercially available multiplex immunohistochemical stains: breast triple stain and LC/DC breast cocktail.

    PubMed

    Ginter, Paula S; Varma, Sonal; Liu, Yi-Fang; Shin, Sandra J

    2015-12-01

    The Minimal Carcinoma (MC) Triple Stain is a tri-chromogen multiplex immunostain (CK7, p63, and E-cadherin) helpful in classifying morphologically ambiguous and/or small carcinomas as either ductal or lobular and/or in situ or invasive. We compared the utility of this stain with two commercially available duplex/multiplex immunostains: Breast Triple Stain (BTS) (Clarient, Aliso Viejo, CA; CK5, p63, and CK8/18) and LC/DC Breast Cocktail (LCDC) (Biocare, Concord, CA; E-cadherin and p120). Ninety-seven mammary carcinomas stained with the MC Triple Stain, BTS, and LCDC were compared. The MC Triple Stain, LCDC, and BTS were diagnostic in 90 (93%) of 97, 82 (85%) of 97, and 85 (88%) of 97 of cases, respectively. All stains showed decreased diagnostic utility due to variability in tissue integrity, quality of the staining, and/or ease of interpretation. In cases where all immunostains were interpretable, the MC Triple Stain yielded the most information. When technically sufficient, all three immunostains demonstrated relative strengths and weaknesses in their ability to provide diagnostic information with the highest consistency and ease of use. Many cases stained with LCDC were technically insufficient due to a suboptimal staining protocol provided by the company. Overall, the MC Triple Stain outperformed BTS and LCDC by more consistently providing more diagnostic information. The MC Triple Stain is a viable alternative to other multiplex immunostains in evaluating small foci of carcinoma, particularly when both the histologic type and extent of disease (in situ vs invasive) require clarification. Copyright© by the American Society for Clinical Pathology.

  3. Nonparametric triple collocation

    USDA-ARS?s Scientific Manuscript database

    Triple collocation derives variance-covariance relationships between three or more independent measurement sources and an indirectly observed truth variable in the case where the measurement operators are linear-Gaussian. We generalize that theory to arbitrary observation operators by deriving nonpa...

  4. Surgical outcome of deep anterior lamellar keratoplasty with air-assisted manual dissection for corneas with previous inflammation or fibrosis

    PubMed Central

    Ho, Yi-Ju; Wu, Cheng-Hsiu; Chen, Hung-Chi; Hsiao, Chin-Shi; Hsueh, Yi-Jen; Ma, David Hui-Kang

    2017-01-01

    PURPOSE: To report our experience in air-assisted manual dissection deep anterior lamellar keratoplasty (DALK) for the treatment of corneal scar with previous inflammation and fibrosis. MATERIALS AND METHODS: We retrospectively reviewed the medical history of 21 patients (male:female = 13:8 mean age 41.9 years old) with corneal pathology from previous infection and inflammation. Trephination diameter ranged from 7.0 to 8.0 mm, and the graft was oversized by 0.25–0.50 mm. Debulking technique was performed to expose Descemet's membrane after filling stroma with air. Starting from postoperative 3 months, selective suture removal was performed to reduce corneal astigmatism. RESULTS: The mean follow-up period was 59.9 ± 19.8 (20–96) months. Intraoperative microperforation occurred in 2 eyes (9.5%); however, there was no shift to penetrating keratoplasty. Air-bubble tamponade was performed in 7 eyes (33.3%) for postoperative gapping of the graft. There were 2 failed grafts (9.5%) due to corneal ulcer while all the other grafts remained clear throughout follow-up. The mean preoperative best-corrected visual acuity (BCVA) was 1.84 ± 0.66 logMAR, which improved to 0.74 ± 0.63 (P < 0.01). The average sphere power was − 0.88 ± 3.88 diopter (D), average cylinder power 3.03 ± 1.46D, and average endothelial count 1877 ± 375 cells/mm2. CONCLUSION: In severe ocular surface diseases, big-bubble technique frequently failed to separate predescemtic plane; however, it effectively created air-filled stroma which was easier to remove. Although BCVA was suboptimal due to ocular surface disorders, graft survival and clarity rate is high, justifying the application of DALK in these cases. PMID:29296551

  5. Measurements of donor endothelial keratoplasty lenticules prepared from fresh donated whole eyes by using ultrasound and optical coherence tomography.

    PubMed

    Kanavi, Mozhgan Rezaei; Nemati, Farzan; Chamani, Tahereh; Kheiri, Bahar; Javadi, Mohammad Ali

    2017-03-01

    This study was conducted to analyze the profile and thickness of endothelial keratoplasty lenticules prepared from fresh donated whole eyes with Visante optical coherence tomography (V-OCT) compared to measurements obtained from ultrasound pachymetry (USP) at the Central Eye Bank of Iran. Microkeratome-assisted precut corneas were prepared for Descemet stripping automated endothelial keratoplasty by using standard eye bank protocol. Central posterior lenticule thickness (CPLT) on fresh whole eye, before excising corneoscleral disc and transferring to Optisol-GS, was measured by USP. V-OCT was used to measure central, paracentral, and midperipheral thicknesses of lenticules after transferring the tissue to Optisol-GS. Chi Square and Bonferroni tests were respectively used to uncover the differences between the USP and V-OCT measurements and also the thickness profile of lenticules. Postoperative reports for the entire transplanted lenticules were recorded. Accordingly, on evaluation of 312 enrolled precut corneas, CPLT measurements by V-OCT versus USP were statistically different (mean: 136 µm vs 165 µm, respectively; P = 0.008). Thickness profile of the posterior lenticules revealed increased thickness from the central to the peripheral parts of the cornea (mean increase of 16 µm at the pericentral and 64.2 µm at the peripheral locations, respectively); however, the increase in the thickness was relatively symmetrical. Postoperative reports of transplanted lenticules were unremarkable, since there were no posterior flap detachments. In essence, V-OCT measurements of microkeratome-assisted precut lenticules prepared from fresh donated whole eyes averaged 29 μm thinner than USP measurements and revealed a significant but symmetric increase of thickness towards the peripheral parts of the corneas. However, the variation in the thickness profile did not affect the attachment or the clarity of transplanted precut lenticlues.

  6. Clinical outcomes of trabeculectomy vs. Ahmed glaucoma valve implantation in patients with penetrating keratoplasty : (Trabeculectomy vs. Ahmed galucoma valve in patients with penetrating keratoplasty).

    PubMed

    Akdemir, Mehmet Orcun; Acar, Banu Torun; Kokturk, Furuzan; Acar, Suphi

    2016-08-01

    The aim of this study was to compare the visual outcomes, intraocular pressure (IOP), and endothelial cell loss caused by trabeculectomy (TRAB) and Ahmed glaucoma valve (AGV) implantation in patients who had previously undergone penetrating keratoplasty (PKP). The data from all patients who underwent surgical treatment of glaucoma after PKP were reviewed at the Cornea Department of Haydarpasa Numune Education and Research Hospital. Eighteen patients who had undergone surgical treatment of glaucoma after PKP were included in this retrospective study. Time between PKP and glaucoma surgeries, visual acuity results, IOP results, endothelial cell counts (ECC) before the surgery, at 1st, 6th, and 12th month of surgery were recorded. Differences between two groups were evaluated. Mean loss of ECC was 315 cells/mm(2) in the AGV group and 197 cells/mm(2) in TRAB group at 12th month of glaucoma surgery. The difference between endothelial cell loss at 12th month of surgery was statistically significant and higher in AGV group (p < 0.001). The decrease in IOP was 64.2 % in AGV group and 46.9 % in TRAB group at 12th month of surgery. Both differences were statistically significant between 2 groups (p = 0.001, 0.001). TRAB successfully decreased both the IOP and endothelial cell loss in patients with post-PKP glaucoma. Ahmed glaucoma valve had a significantly better IOP lowering but higher endothelial cell loss effect.

  7. Vectorized data acquisition and fast triple-correlation integrals for Fluorescence Triple Correlation Spectroscopy

    NASA Astrophysics Data System (ADS)

    Ridgeway, William K.; Millar, David P.; Williamson, James R.

    2013-04-01

    Fluorescence Correlation Spectroscopy (FCS) is widely used to quantify reaction rates and concentrations of molecules in vitro and in vivo. We recently reported Fluorescence Triple Correlation Spectroscopy (F3CS), which correlates three signals together instead of two. F3CS can analyze the stoichiometries of complex mixtures and detect irreversible processes by identifying time-reversal asymmetries. Here we report the computational developments that were required for the realization of F3CS and present the results as the Triple Correlation Toolbox suite of programs. Triple Correlation Toolbox is a complete data analysis pipeline capable of acquiring, correlating and fitting large data sets. Each segment of the pipeline handles error estimates for accurate error-weighted global fitting. Data acquisition was accelerated with a combination of off-the-shelf counter-timer chips and vectorized operations on 128-bit registers. This allows desktop computers with inexpensive data acquisition cards to acquire hours of multiple-channel data with sub-microsecond time resolution. Off-line correlation integrals were implemented as a two delay time multiple-tau scheme that scales efficiently with multiple processors and provides an unprecedented view of linked dynamics. Global fitting routines are provided to fit FCS and F3CS data to models containing up to ten species. Triple Correlation Toolbox is a complete package that enables F3CS to be performed on existing microscopes. Catalogue identifier: AEOP_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEOP_v1_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 50189 No. of bytes in distributed program, including test data, etc.: 6135283 Distribution format: tar.gz Programming language: C/Assembly. Computer: Any with GCC and

  8. Fixed Point Problems for Linear Transformations on Pythagorean Triples

    ERIC Educational Resources Information Center

    Zhan, M.-Q.; Tong, J.-C.; Braza, P.

    2006-01-01

    In this article, an attempt is made to find all linear transformations that map a standard Pythagorean triple (a Pythagorean triple [x y z][superscript T] with y being even) into a standard Pythagorean triple, which have [3 4 5][superscript T] as their fixed point. All such transformations form a monoid S* under matrix product. It is found that S*…

  9. Homomorphisms in C*-ternary algebras and JB*-triples

    NASA Astrophysics Data System (ADS)

    Park, Choonkil; Rassias, Themistocles M.

    2008-01-01

    In this paper, we investigate homomorphisms between C*-ternary algebras and derivations on C*-ternary algebras, and homomorphisms between JB*-triples and derivations on JB*-triples, associated with the following Apollonius type additive functional equation

  10. Triple valve surgery: a 25-year experience.

    PubMed

    Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen

    2004-09-01

    Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become

  11. Triple X syndrome: a review of the literature.

    PubMed

    Otter, Maarten; Schrander-Stumpel, Constance T R M; Curfs, Leopold M G

    2010-03-01

    The developmental and clinical aspects in the literature on triple X syndrome are reviewed. Prenatal diagnosis depends on karyotyping. The incidence is 1 of 1000 females. At birth, 47,XXX girls have a lower mean birth weight and a smaller head circumference. Triple X diagnosis was not suspected at birth. The maternal age seems to be increased. Toddlers with triple X syndrome show delayed language development. The youngest girls show accelerated growth until puberty. EEG abnormalities seem to be rather common. Many girls show motor-coordination problems and auditory-processing disorders are not rare. Scoliosis is probably more common in adolescent cases. The IQ levels are 20 points below that of controls, and verbal IQ is lowest. The girls struggle with low self-esteem and they need psychological, behavioural and educational support. They perform best in stable families. After leaving school they seem to feel better. In adults, premature ovarian failure seems to be more prevalent than in controls. MRIs of the brain seem to show decreased brain volumes. The 47,XXX women most often find jobs that reflect their performance abilities. Psychotic illness seems to be more prevalent in triple X adult women than in controls. Psychotic disorders respond well to psychotropic drugs. Triple X adults suffer more frequently from cyclothymic and labile personality traits. Research on triple X syndrome may yield more insight into brain and behaviour relations, developmental psychopathology, auditory-processing disorders, EEG disorders, personality and psychotic disorders, etc.

  12. Existence Regions of Shock Wave Triple Configurations

    ERIC Educational Resources Information Center

    Bulat, Pavel V.; Chernyshev, Mikhail V.

    2016-01-01

    The aim of the research is to create the classification for shock wave triple configurations and their existence regions of various types: type 1, type 2, type 3. Analytical solutions for limit Mach numbers and passing shock intensity that define existence region of every type of triple configuration have been acquired. The ratios that conjugate…

  13. On Pythagoras Theorem for Products of Spectral Triples

    NASA Astrophysics Data System (ADS)

    D'Andrea, Francesco; Martinetti, Pierre

    2013-05-01

    We discuss a version of Pythagoras theorem in noncommutative geometry. Usual Pythagoras theorem can be formulated in terms of Connes' distance, between pure states, in the product of commutative spectral triples. We investigate the generalization to both non-pure states and arbitrary spectral triples. We show that Pythagoras theorem is replaced by some Pythagoras inequalities, that we prove for the product of arbitrary (i.e. non-necessarily commutative) spectral triples, assuming only some unitality condition. We show that these inequalities are optimal, and we provide non-unital counter-examples inspired by K-homology.

  14. Development of 600 kV triple resonance pulse transformer.

    PubMed

    Li, Mingjia; Zhang, Faqiang; Liang, Chuan; Xu, Zhou

    2015-06-01

    In this paper, a triple-resonance pulse transformer based on an air-core transformer is introduced. The voltage across the high-voltage winding of the air-core transformer is significantly less than the output voltage; instead, the full output voltage appears across the tuning inductor. The maximum ratio of peak load voltage to peak transformer voltage is 2.77 in theory. By analyzing pulse transformer's lossless circuit, the analytical expression for the output voltage and the characteristic equation of the triple-resonance circuit are presented. Design method for the triple-resonance pulse transformer (iterated simulation method) is presented, and a triple-resonance pulse transformer is developed based on the existing air-core transformer. The experimental results indicate that the maximum ratio of peak voltage across the load to peak voltage across the high-voltage winding of the air-core transformer is approximately 2.0 and the peak output voltage of the triple-resonance pulse transformer is approximately 600 kV.

  15. 'Blue bubble' technique: an ab interno approach for Descemet separation in deep anterior lamellar keratoplasty using trypan blue stained viscoelastic device.

    PubMed

    Livny, Eitan; Bahar, Irit; Hammel, Naama; Nahum, Yoav

    2018-04-01

    In this study, we examined a novel variant of 'big-bubble' deep anterior lamellar keratoplasty using trypan-blue-stained viscoelastic device for the creation of a pre-descemetic bubble. Ten corneoscleral rims were mounted on an artificial anterior chamber (AC). The AC was filled with air through a limbal paracentesis. A Melles' triangulated spatula was inserted through the paracentesis, with its tip penetrating the AC, was then slightly retracted and pushed into the deep stroma above the roof of the paracentesis. A mixture of trypan blue and viscoelastic device (Healon, Abbott Medical Optics, Abbott Park, Illinois) was injected into this intra-stromal pocket using a 27-G cannula to create a pre-descemetic separation bubble. Bubble type and visualization of dyed viscoelastic device were noted. The method was later employed in three cases. In all 10 corneoscleral rims, the technique successfully created a visible pre-descemetic (type 1) bubble that could be expanded up to the predicted diameter of trephination. Subsequent trephination and the removal of corneal stroma were uneventful. In two out of four clinical cases, a type 1 bubble was created, while in two others, visco-dissection failed and dyed viscoelastic was seen in the AC. The presented technique holds promise of being a relatively easy to perform, predictable and well-controlled alternative for achieving a type 1 bubble during deep anterior lamellar keratoplasty surgery. The trypan-blue-stained viscoelastic device facilitates proper visualization and control of the separation bubble and assists in identifying the penetrance to the separation bubble prior to removal of the stromal cap. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  16. Pursuing the Triple Aim: The First 7 Years.

    PubMed

    Whittington, John W; Nolan, Kevin; Lewis, Ninon; Torres, Trissa

    2015-06-01

    POLICY POINTS: In 2008, researchers at the Institute for Healthcare Improvement (IHI) proposed the Triple Aim, strategic organizing principles for health care organizations and geographic communities that seek, simultaneously, to improve the individual experience of care and the health of populations and to reduce the per capita costs of care for populations. In 2010, the Triple Aim became part of the US national strategy for tackling health care issues, especially in the implementation of the Patient Protection and Affordable Care Act (ACA) of 2010. Since that time, IHI and others have worked together to determine how the implementation of the Triple Aim has progressed. Drawing on our 7 years of experience, we describe 3 major principles that guided the organizations and communities working on this endeavor: creating the right foundation for population management, managing services at scale for the population, and establishing a learning system to drive and sustain the work over time. In 2008, researchers at the Institute for Healthcare Improvement (IHI) described the Triple Aim as simultaneously "improving the individual experience of care; improving the health of populations; and reducing the per capita costs of care for populations." IHI and its close colleagues had determined that both individual and societal changes were needed. In 2007, IHI began recruiting organizations from around the world to participate in a collaborative to implement what became known as the Triple Aim. The 141 participating organizations included health care systems, hospitals, health care insurance companies, and others closely tied to health care. In addition, key groups outside the health care system were represented, such as public health agencies, social services groups, and community coalitions. This collaborative provided a structure for observational research. By noting the contrasts between the contexts and structures of those sites in the collaborative that progressed and

  17. On the stability and collisions in triple stellar systems

    NASA Astrophysics Data System (ADS)

    He, Matthias Y.; Petrovich, Cristobal

    2018-02-01

    A significant fraction of main-sequence (MS) stars are part of a triple system. We study the long-term stability and dynamical outcomes of triple stellar systems using a large number of long-term direct N-body integrations with relativistic precession. We find that the previously proposed stability criteria by Eggleton & Kiseleva and Mardling & Aarseth predict the stability against ejections reasonably well for a wide range of parameters. Assuming that the triple stellar systems follow orbital and mass distributions from FGK binary stars in the field, we find that ˜ 1 per cent and ˜ 0.5 per cent of the triple systems lead to a direct head-on collision (impact velocity ˜ escape velocity) between MS stars and between a MS star and a stellar-mass compact object, respectively. We conclude that triple interactions are the dominant channel for direct collisions involving a MS star in the field with a rate of one event every ˜100 years in the Milky Way. We estimate that the fraction of triple systems that form short-period binaries is up to ˜ 23 per cent with only up to ˜ 13 per cent being the result of three-body interactions with tidal dissipation, which is consistent with previous work using a secular code.

  18. Risk factors for donor endothelial loss in eye bank-prepared posterior lamellar corneal tissue for descemet stripping automated endothelial keratoplasty.

    PubMed

    Liu, Yu-Chi; Alvarez Paraz, Carisa M; Cajucom-Uy, Howard Yu; Agahari, Djoni; Sethuraman, Selvam; Tan, Donald T-H; Mehta, Jodhbir S

    2014-07-01

    The aim of this study was to investigate donor, tissue, and precut procedure risk factors for endothelial cell density (ECD) loss in posterior lamellar corneal tissue preparation by an eye bank for Descemet stripping automated endothelial keratoplasty. A total of 259 corneoscleral rims precut by the Singapore Eye Bank from October 2011 to August 2013 were evaluated. Donor characteristics, tissue characteristics, and precut procedure parameters were analyzed. The mean donor age was 57.18 ± 11.35 years, and the mean cutting transition time was 4.16 ± 0.75 seconds. The mean ECD was 2826 ± 225 and 2787 ± 224 cells per square millimeter before and after precutting, respectively, with an average ECD change of -1.38% ± 3.28%. The precutting procedure failure rate was 1.2%. Mutivariate regression analysis showed that an older donor age, a higher ECD before cutting, and a slower cutting transition speed were significant factors. Corneas with an ECD >2800 cells per square millimeter before precutting, cutting transition time >5.5 seconds, and corneas with donor age >65 years were significantly more likely to have greater than 5% ECD loss after precutting (odds ratio, 6.42, 1.66, and 1.62; 95% confidence interval, 1.44-29.43, 1.45-2.72, and 1.66-5.82, respectively). Donor source, death-to-preservation time (range, 0.67-10.88 hours), death-to-precutting time (range, 0-7 days), and graft thickness (range, 43-232 μm) were not statistically significant factors. The ECD loss in the precut tissue prepared by the eye bank was very low. The risk factors identified provide better understanding of how to improve the quality and safety profiles when preparing graft tissue for Descemet stripping automated endothelial keratoplasty.

  19. Triple shape memory polymers by 4D printing

    NASA Astrophysics Data System (ADS)

    Bodaghi, M.; Damanpack, A. R.; Liao, W. H.

    2018-06-01

    This article aims at introducing triple shape memory polymers (SMPs) by four-dimensional (4D) printing technology and shaping adaptive structures for mechanical/bio-medical devices. The main approach is based on arranging hot–cold programming of SMPs with fused decomposition modeling technology to engineer adaptive structures with triple shape memory effect (SME). Experiments are conducted to characterize elasto-plastic and hyper-elastic thermo-mechanical material properties of SMPs in low and high temperatures at large deformation regime. The feasibility of the dual and triple SMPs with self-bending features is demonstrated experimentally. It is advantageous in situations either where it is desired to perform mechanical manipulations on the 4D printed objects for specific purposes or when they experience cold programming inevitably before activation. A phenomenological 3D constitutive model is developed for quantitative understanding of dual/triple SME of SMPs fabricated by 4D printing in the large deformation range. Governing equations of equilibrium are established for adaptive structures on the basis of the nonlinear Green–Lagrange strains. They are then solved by developing a finite element approach along with an elastic-predictor plastic-corrector return map procedure accomplished by the Newton–Raphson method. The computational tool is applied to simulate dual/triple SMP structures enabled by 4D printing and explore hot–cold programming mechanisms behind material tailoring. It is shown that the 4D printed dual/triple SMPs have great potential in mechanical/bio-medical applications such as self-bending gripers/stents and self-shrinking/tightening staples.

  20. Government and Governance of Regional Triple Helix Interactions

    ERIC Educational Resources Information Center

    Danson, Mike; Todeva, Emanuela

    2016-01-01

    This conceptual paper contributes to the discussion of the role of regional government and regional Triple Helix constellations driving economic development and growth within regional boundaries. The impact of regionalism and subsidiarity on regional Triple Helix constellations, and the questions of governmentality, governance and institutional…

  1. Overcoming Triple Segregation

    ERIC Educational Resources Information Center

    Gandara, Patricia

    2010-01-01

    Latinos are, after whites, the most segregated student group in the United States, and their segregation is closely tied to poor academic outcomes. Latinos experience a triple segregation: by race/ethnicity, poverty, and language. Racial segregation perpetuates negative stereotypes, reduces the likelihood of a strong teaching staff, and is often…

  2. Femtosecond Laser-Assisted Descemetorhexis: A Novel Technique in Descemet Membrane Endothelial Keratoplasty.

    PubMed

    Pilger, Daniel; von Sonnleithner, Christoph; Bertelmann, Eckart; Joussen, Antonia M; Torun, Necip

    2016-10-01

    To explore the feasibility of femtosecond laser-assisted descemetorhexis (DR) to facilitate Descemet membrane endothelial keratoplasty (DMEK) surgery. Six pseudophakic patients suffering from Fuchs' endothelial dystrophy underwent femtosecond laser-assisted DMEK surgery. DR was performed using the LenSx femtosecond laser, followed by manual removal of the Descemet membrane. Optical coherence tomography images were used to measure DR parameters. Patients were followed up for 1 month to examine best corrected visual acuity, endothelial cell loss, flap detachment, and structure of the anterior chamber of the eye. The diameter of the DR approximated the intended diameter closely [mean error of 34 μm (0.45%) and 54 μm (0.67%) in the x- and y-diameter, respectively] and did not require manual correction. The median visual acuity increased from 0.4 logMAR (range 0.6-0.4 logMAR) preoperative to 0.2 logMAR (range 0-0.4 logMAR) postoperative. The median endothelial cell loss was 22% (range 7%-34%). No clinically significant flap detachments were noted. All patients had clear corneas after surgery, and no side effects or damage to structures of the anterior chamber were noted. Femtosecond laser-assisted DR is a safe and precise method for facilitating DMEK surgery.

  3. A reconstruction theorem for Connes-Landi deformations of commutative spectral triples

    NASA Astrophysics Data System (ADS)

    Ćaćić, Branimir

    2015-12-01

    We formulate and prove an extension of Connes's reconstruction theorem for commutative spectral triples to so-called Connes-Landi or isospectral deformations of commutative spectral triples along the action of a compact Abelian Lie group G, also known as toric noncommutative manifolds. In particular, we propose an abstract definition for such spectral triples, where noncommutativity is entirely governed by a deformation parameter sitting in the second group cohomology of the Pontryagin dual of G, and then show that such spectral triples are well-behaved under further Connes-Landi deformation, thereby allowing for both quantisation from and dequantisation to G-equivariant abstract commutative spectral triples. We then use a refinement of the Connes-Dubois-Violette splitting homomorphism to conclude that suitable Connes-Landi deformations of commutative spectral triples by a rational deformation parameter are almost-commutative in the general, topologically non-trivial sense.

  4. Gauge transformations for twisted spectral triples

    NASA Astrophysics Data System (ADS)

    Landi, Giovanni; Martinetti, Pierre

    2018-05-01

    It is extended to twisted spectral triples the fluctuations of the metric as bounded perturbations of the Dirac operator that arises when a spectral triple is exported between Morita equivalent algebras, as well as gauge transformations which are obtained by the action of the unitary endomorphisms of the module implementing the Morita equivalence. It is firstly shown that the twisted-gauged Dirac operators, previously introduced to generate an extra scalar field in the spectral description of the standard model of elementary particles, in fact follow from Morita equivalence between twisted spectral triples. The law of transformation of the gauge potentials turns out to be twisted in a natural way. In contrast with the non-twisted case, twisted fluctuations do not necessarily preserve the self-adjointness of the Dirac operator. For a self-Morita equivalence, conditions are obtained in order to maintain self-adjointness that are solved explicitly for the minimal twist of a Riemannian manifold.

  5. Pursuing the Triple Aim: The First 7 Years

    PubMed Central

    Whittington, John W; Nolan, Kevin; Lewis, Ninon; Torres, Trissa

    2015-01-01

    Context In 2008, researchers at the Institute for Healthcare Improvement (IHI) described the Triple Aim as simultaneously “improving the individual experience of care; improving the health of populations; and reducing the per capita costs of care for populations.” IHI and its close colleagues had determined that both individual and societal changes were needed. Methods In 2007, IHI began recruiting organizations from around the world to participate in a collaborative to implement what became known as the Triple Aim. The 141 participating organizations included health care systems, hospitals, health care insurance companies, and others closely tied to health care. In addition, key groups outside the health care system were represented, such as public health agencies, social services groups, and community coalitions. This collaborative provided a structure for observational research. By noting the contrasts between the contexts and structures of those sites in the collaborative that progressed and those that did not, we were able to develop an ex post theory of what is needed for an organization or community to successfully pursue the Triple Aim. Findings Drawing on our 7 years of experience, we describe the 3 major principles that guided the organizations and communities working on the Triple Aim: creating the right foundation for population management, managing services at scale for the population, and establishing a learning system to drive and sustain the work over time. Conclusions The concept of the Triple Aim is now widely used, because of IHI's work with many organizations and also because of the adoption of the Triple Aim as part of the national strategy for US health care, developed during the implementation of the Patient Protection and Affordable Care Act of 2010. Even those organizations working on the Triple Aim before IHI coined the term found our concept to be useful because it helped them think about all 3 dimensions at once and organize their

  6. A directional nucleation-zipping mechanism for triple helix formation

    PubMed Central

    Alberti, Patrizia; Arimondo, Paola B.; Mergny, Jean-Louis; Garestier, Thérèse; Hélène, Claude; Sun, Jian-Sheng

    2002-01-01

    A detailed kinetic study of triple helix formation was performed by surface plasmon resonance. Three systems were investigated involving 15mer pyrimidine oligonucleotides as third strands. Rate constants and activation energies were validated by comparison with thermodynamic values calculated from UV-melting analysis. Replacement of a T·A base pair by a C·G pair at either the 5′ or the 3′ end of the target sequence allowed us to assess mismatch effects and to delineate the mechanism of triple helix formation. Our data show that the association rate constant is governed by the sequence of base triplets on the 5′ side of the triplex (referred to as the 5′ side of the target oligopurine strand) and provides evidence that the reaction pathway for triple helix formation in the pyrimidine motif proceeds from the 5′ end to the 3′ end of the triplex according to the nucleation-zipping model. It seems that this is a general feature for all triple helices formation, probably due to the right-handedness of the DNA double helix that provides a stronger base stacking at the 5′ than at the 3′ duplex–triplex junction. Understanding the mechanism of triple helix formation is not only of fundamental interest, but may also help in designing better triple helix-forming oligonucleotides for gene targeting and control of gene expression. PMID:12490709

  7. Collagenolytic Matrix Metalloproteinase Activities toward Peptomeric Triple-Helical Substrates.

    PubMed

    Stawikowski, Maciej J; Stawikowska, Roma; Fields, Gregg B

    2015-05-19

    Although collagenolytic matrix metalloproteinases (MMPs) possess common domain organizations, there are subtle differences in their processing of collagenous triple-helical substrates. In this study, we have incorporated peptoid residues into collagen model triple-helical peptides and examined MMP activities toward these peptomeric chimeras. Several different peptoid residues were incorporated into triple-helical substrates at subsites P3, P1, P1', and P10' individually or in combination, and the effects of the peptoid residues were evaluated on the activities of full-length MMP-1, MMP-8, MMP-13, and MMP-14/MT1-MMP. Most peptomers showed little discrimination between MMPs. However, a peptomer containing N-methyl Gly (sarcosine) in the P1' subsite and N-isobutyl Gly (NLeu) in the P10' subsite was hydrolyzed efficiently only by MMP-13 [nomenclature relative to the α1(I)772-786 sequence]. Cleavage site analysis showed hydrolysis at the Gly-Gln bond, indicating a shifted binding of the triple helix compared to the parent sequence. Favorable hydrolysis by MMP-13 was not due to sequence specificity or instability of the substrate triple helix but rather was based on the specific interactions of the P7' peptoid residue with the MMP-13 hemopexin-like domain. A fluorescence resonance energy transfer triple-helical peptomer was constructed and found to be readily processed by MMP-13, not cleaved by MMP-1 and MMP-8, and weakly hydrolyzed by MT1-MMP. The influence of the triple-helical structure containing peptoid residues on the interaction between MMP subsites and individual substrate residues may provide additional information about the mechanism of collagenolysis, the understanding of collagen specificity, and the design of selective MMP probes.

  8. CRITICAL CURVES AND CAUSTICS OF TRIPLE-LENS MODELS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daněk, Kamil; Heyrovský, David, E-mail: kamil.danek@utf.mff.cuni.cz, E-mail: heyrovsky@utf.mff.cuni.cz

    2015-06-10

    Among the 25 planetary systems detected up to now by gravitational microlensing, there are two cases of a star with two planets, and two cases of a binary star with a planet. Other, yet undetected types of triple lenses include triple stars or stars with a planet with a moon. The analysis and interpretation of such events is hindered by the lack of understanding of essential characteristics of triple lenses, such as their critical curves and caustics. We present here analytical and numerical methods for mapping the critical-curve topology and caustic cusp number in the parameter space of n-point-mass lenses.more » We apply the methods to the analysis of four symmetric triple-lens models, and obtain altogether 9 different critical-curve topologies and 32 caustic structures. While these results include various generic types, they represent just a subset of all possible triple-lens critical curves and caustics. Using the analyzed models, we demonstrate interesting features of triple lenses that do not occur in two-point-mass lenses. We show an example of a lens that cannot be described by the Chang–Refsdal model in the wide limit. In the close limit we demonstrate unusual structures of primary and secondary caustic loops, and explain the conditions for their occurrence. In the planetary limit we find that the presence of a planet may lead to a whole sequence of additional caustic metamorphoses. We show that a pair of planets may change the structure of the primary caustic even when placed far from their resonant position at the Einstein radius.« less

  9. Triple Helix

    DTIC Science & Technology

    2008-08-01

    and sponsoring FIRST teams at the Junior FIRST Lego League (JFLL) and the FIRST Lego League (FLL) levels in elementary and middle school . As such, the...a Final Technical Report for Year I Grant W911NF-07-1-0663 with the Newport News Public School District for the Menchville High School Robotics Team...August 2008 TRIPL HELIX 0 Menchville High School Newport News, VA 20080829081 w DEFENSE TECHNICAL INFORMATION CENTER bfro do.A icfr tkw, Def&*ue, Cow

  10. Triple helix purification and sequencing

    DOEpatents

    Wang, Renfeng; Smith, Lloyd M.; Tong, Xinchun E.

    1995-01-01

    Disclosed herein are methods, kits, and equipment for purifying single stranded circular DNA and then using the DNA for DNA sequencing purposes. Templates are provided with an insert having a hybridization region. An elongated oligonucleotide has two regions that are complementary to the insert and the oligo is bound to a magnetic anchor. The oligo hybridizes to the insert on two sides to form a stable triple helix complex. The anchor can then be used to drag the template out of solution using a magnet. The system can purify sequencing templates, and if desired the triple helix complex can be opened up to a double helix so that the oligonucleotide will act as a primer for further DNA synthesis.

  11. Localized Triple Modular Redundancy vs. Distributed Triple Modular Redundancy on a ProASIC3E Reprogrammable FPGA

    NASA Technical Reports Server (NTRS)

    McGuffey, Alex; Berg, Melanie; Pellish, Jonathan

    2010-01-01

    Field programmable gate arrays (FPGA) are used in every space application. Currently, most space flight applications use radiation hardened (RH) FPGAs, which are very expensive. There is a desire to use cheaper, commercial off the shelf reprogrammable FPGAs, which are more susceptible to radiation effects known as single-event effects (SEE). The RH parts have SEE and total ionizing dose (TID) hardened elements pre-integrated into the part. This means that the designer does not need to implement any hardening techniques while configuring the device. The COTS parts on the other hand must be mitigated by design in order to insure any form of mitigation. The design techniques this project examines concern the use of localized triple modular redundancy (LTMR) and distributed triple modular redundancy (DTMR). LTMR triples every flip flop in the device architecture while DTMR triples everything except for the global routes (clocks, resets, and enables). The testing was performed on a ProASIC3E FPGA at the Texas A&M cyclotron facility. Two design architectures were used: shift registers and counters, both with LTMR and DTMR mitigation techniques. The test results prove that DTMR is more effective at reducing SEE than LTMR. We also determined that there was not a significant difference between the use of shift registers and counters for test purposes. More testing is required to obtain additional linear energy transfer values for each architecture and mitigation technique in order to determine the most cost-effective method of SEE mitigation.

  12. Two-week, high-dose proton pump inhibitor, moxifloxacin triple Helicobacter pylori therapy after failure of standard triple or non-bismuth quadruple treatments.

    PubMed

    Gisbert, Javier P; Romano, Marco; Molina-Infante, Javier; Lucendo, Alfredo J; Medina, Enrique; Modolell, Inés; Rodríguez-Tellez, Manuel; Gomez, Blas; Barrio, Jesús; Perona, Monica; Ortuño, Juan; Ariño, Inés; Domínguez-Muñoz, Juan Enrique; Perez-Aisa, Ángeles; Bermejo, Fernando; Domínguez, Jose Luis; Almela, Pedro; Gomez-Camarero, Judith; Millastre, Judith; Martin-Noguerol, Elisa; Gravina, Antonietta G; Martorano, Marco; Miranda, Agnese; Federico, Alessandro; Fernandez-Bermejo, Miguel; Angueira, Teresa; Ferrer-Barcelo, Luis; Fernández, Nuria; Marín, Alicia C; McNicholl, Adrián G

    2015-02-01

    Aim was to evaluate the efficacy and tolerability of a moxifloxacin-containing second-line triple regimen in patients whose previous Helicobacter pylori eradication treatment failed. Prospective multicentre study including patients in whom a triple therapy or a non-bismuth-quadruple-therapy failed. Moxifloxacin (400mg qd), amoxicillin (1g bid), and esomeprazole (40 mg bid) were prescribed for 14 days. Eradication was confirmed by (13)C-urea-breath-test. Compliance was determined through questioning and recovery of empty medication envelopes. 250 patients were consecutively included (mean age 48 ± 15 years, 11% with ulcer). Previous (failed) therapy included: standard triple (n = 179), sequential (n = 27), and concomitant (n = 44); 97% of patients took all medications, 4 were lost to follow-up. Intention-to-treat and per-protocol eradication rates were 82.4% (95% CI, 77-87%) and 85.7% (95% CI, 81-90%). Cure rates were similar independently of diagnosis (ulcer, 77%; dyspepsia, 82%) and previous treatment (standard triple, 83%; sequential, 89%; concomitant, 77%). At multivariate analysis, only age was associated with eradication (OR = 0.957; 95% CI, 0.933-0.981). Adverse events were reported in 25.2% of patients: diarrhoea (9.6%), abdominal pain (9.6%), and nausea (9.2%). 14-day moxifloxacin-containing triple therapy is an effective and safe second-line strategy in patients whose previous standard triple therapy or non-bismuth quadruple (sequential or concomitant) therapy has failed, providing a simple alternative to bismuth quadruple regimen. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  13. Outcome Measures of Triple Board Graduates, 1991-2003

    ERIC Educational Resources Information Center

    Warren, Marla J.; Dunn, David W.; Rushton, Jerry

    2006-01-01

    Objective: To describe program outcomes for the Combined Training Program in Child and Adolescent Psychiatry, Pediatrics, and Psychiatry (Triple Board Program). Method: All Triple Board Program graduates to date (1991-2003) were asked to participate in a 37-item written survey from February to April 2004. Results: The response rate was 80.7%. Most…

  14. Peptide tessellation yields micrometre-scale collagen triple helices

    NASA Astrophysics Data System (ADS)

    Tanrikulu, I. Caglar; Forticaux, Audrey; Jin, Song; Raines, Ronald T.

    2016-11-01

    Sticky-ended DNA duplexes can associate spontaneously into long double helices; however, such self-assembly is much less developed with proteins. Collagen is the most prevalent component of the extracellular matrix and a common clinical biomaterial. As for natural DNA, the ~103-residue triple helices (~300 nm) of natural collagen are recalcitrant to chemical synthesis. Here we show how the self-assembly of short collagen-mimetic peptides (CMPs) can enable the fabrication of synthetic collagen triple helices that are nearly a micrometre in length. Inspired by the mathematics of tessellations, we derive rules for the design of single CMPs that self-assemble into long triple helices with perfect symmetry. Sticky ends thus created are uniform across the assembly and drive its growth. Enacting this design yields individual triple helices that, in length, match or exceed those in natural collagen and are remarkably thermostable, despite the absence of higher-order association. The symmetric assembly of CMPs provides an enabling platform for the development of advanced materials for medicine and nanotechnology.

  15. Endothelial cell density to predict endothelial graft failure after penetrating keratoplasty.

    PubMed

    Lass, Jonathan H; Sugar, Alan; Benetz, Beth Ann; Beck, Roy W; Dontchev, Mariya; Gal, Robin L; Kollman, Craig; Gross, Robert; Heck, Ellen; Holland, Edward J; Mannis, Mark J; Raber, Irving; Stark, Walter; Stulting, R Doyle

    2010-01-01

    To determine whether preoperative and/or postoperative central endothelial cell density (ECD) and its rate of decline postoperatively are predictive of graft failure caused by endothelial decompensation following penetrating keratoplasty to treat a moderate-risk condition, principally, Fuchs dystrophy or pseudophakic corneal edema. In a subset of Cornea Donor Study participants, a central reading center determined preoperative and postoperative ECD from available specular images for 17 grafts that failed because of endothelial decompensation and 483 grafts that did not fail. Preoperative ECD was not predictive of graft failure caused by endothelial decompensation (P = .91). However, the 6-month ECD was predictive of subsequent failure (P < .001). Among those that had not failed within the first 6 months, the 5-year cumulative incidence (+/-95% confidence interval) of failure was 13% (+/-12%) for the 33 participants with a 6-month ECD of less than 1700 cells/mm(2) vs 2% (+/-3%) for the 137 participants with a 6-month ECD of 2500 cells/mm(2) or higher. After 5 years' follow-up, 40 of 277 participants (14%) with a clear graft had an ECD below 500 cells/mm(2). Preoperative ECD is unrelated to graft failure from endothelial decompensation, whereas there is a strong correlation of ECD at 6 months with graft failure from endothelial decompensation. A graft can remain clear after 5 years even when the ECD is below 500 cells/mm(2).

  16. Therapeutic penetrating keratoplasty in severe fungal keratitis using cryopreserved donor corneas

    PubMed Central

    Yao, Y-F; Zhang, Y-M; Zhou, P; Zhang, B; Qiu, W-Y; Tseng, S C G

    2003-01-01

    Aims: To investigate whether cryopreserved donor cornea could be used for therapeutic penetrating keratoplasty (PKP) to eradicate the infection, obviate complications, and preserve anatomical integrity in severe fungal keratitis. Methods: In this retrospective, consecutive case series, 45 eyes of 45 patients with severe fungal keratitis, which exhibited anterior chamber collapse, corneal perforation, and/or large suppurative corneal infiltrate, received therapeutic PKP after removal of the infected corneal tissue, irrigation of the anterior chamber by 0.2% fluconazole solution, iris dissection of fibrinoid membrane, and iridectomy and therapeutic PKP using corneas cryopreserved at −20°C. Results: Among 45 eyes, 39 eyes (86.7%) were successfully eradicated the fungal infection without recurrence and maintained their anatomical integrity without any complication. Four of 45 eyes (8.9%) showed postoperative rise of intraocular pressure, of which three were controlled with subsequent antiglaucoma surgeries, whereas one eye needed additional antiglaucoma medications. Two of 45 eyes (4.4%) were enucleated because of uncontrollable fungal infection and secondary retinal detachment, respectively. 23 eyes received subsequent optical PKP and, among them, 21 maintained clear corneal grafts and two suffered from graft failure due to allograft rejections. Conclusion: Cryopreserved donor corneas are effective substitutes in therapeutic PKP to control severe fungal corneal infection and preserve the global integrity, and may offer additional advantages over conventional PKP in reducing allograft rejection, eradicating fungal infection during the postoperative period, and improving the success of optical PKP for visual rehabilitation. PMID:12714387

  17. OPTICS OF CONDUCTIVE KERATOPLASTY: IMPLICATIONS FOR PRESBYOPIA MANAGEMENT

    PubMed Central

    Hersh, Peter S

    2005-01-01

    Purpose To define the corneal optics of conductive keratoplasty (CK) and assess the clinical implications for hyperopia and presbyopia management. Methods Four analyses were done. (1) Multifocal effects: In a prospective study of CK, uncorrected visual acuity (UCVA) for a given refractive error in 72 postoperative eyes was compared to control eyes. (2) Surgically induced astigmatism (SIA): 203 eyes were analyzed for magnitude and axis of SIA. (3) Higher-order optical aberrations: Corneal higher-order optical aberrations were assessed for 36 eyes after CK and a similar patient population after hyperopic laser in situ keratomileusis (LASIK). (4) Presbyopia clinical trial: Visual acuity, refractive result, and patient questionnaires were analyzed for 150 subjects in a prospective, multicenter clinical trial of presbyopia management with CK. Results (1) 63% and 82% of eyes after CK had better UCVA at distance and near, respectively, than controls. (2) The mean SIA was 0.23 diopter (D) steepening at 175° (P < .001); mean magnitude was 0.66 D (SD, 0.43 D). (3) After CK, composite fourth- and sixth-order spherical aberration increased; change in (Z12) spherical aberration alone was not statistically significant. When compared to hyperopic LASIK, there was a statistically significant increase in composite fourth- and sixth-order spherical aberration (P < .01) and spherical aberration (Z12) alone (P < .02); spherical aberration change was more prolate after CK. (4) After the CK monovision procedure, 80% of patients had J3 or better binocular UCVA at near; 84% of patients were satisfied. Satisfaction was associated with near UCVA of J3 or better in the monovision eye (P = .001) and subjectively good postoperative depth perception (P = .038). Conclusions CK seems to produce functional corneal multifocality with definable introduction of SIA and higher-order optical aberrations, and development of a more prolate corneal contour. These optical factors may militate toward

  18. Sound transmission through triple-panel structures lined with poroelastic materials

    NASA Astrophysics Data System (ADS)

    Liu, Yu

    2015-03-01

    In this paper, previous theories on the prediction of sound transmission loss for a double-panel structure lined with poroelastic materials are extended to address the problem of a triple-panel structure. Six typical configurations are considered for a triple-panel structure based on the method of coupling the porous layers to the facing panels which determines critically the sound insulation performance of the system. The transfer matrix method is employed to solve the system by applying appropriate types of boundary conditions for these configurations. The transmission loss of the triple-panel structures in a diffuse sound field is calculated as a function of frequency and compared with that of corresponding double-panel structures. Generally, the triple-panel structure with poroelastic linings has superior acoustic performance to the double-panel counterpart, remarkably in the mid-high frequency range and possibly at low frequencies, by selecting appropriate configurations in which those with two air gaps in the structure exhibit the best overall performance over the entire frequency range. The poroelastic lining significantly lowers the cut-on frequency above which the triple-panel structure exhibits noticeably higher transmission loss. Compared with a double-panel structure, the wider range of system parameters for a triple-panel structure due to the additional partition provides more design space for tuning the sound insulation performance. Despite the increased structural complexity, the triple-panel structure lined with poroelastic materials has the obvious advantages in sound transmission loss while without the penalties in weight and volume, and is hence a promising replacement for the widely used double-panel sandwich structure.

  19. Triple loop heat exchanger for an absorption refrigeration system

    DOEpatents

    Reimann, Robert C.

    1984-01-01

    A triple loop heat exchanger for an absorption refrigeration system is disclosed. The triple loop heat exchanger comprises portions of a strong solution line for conducting relatively hot, strong solution from a generator to a solution heat exchanger of the absorption refrigeration system, conduit means for conducting relatively cool, weak solution from the solution heat exchanger to the generator, and a bypass system for conducting strong solution from the generator around the strong solution line and around the solution heat exchanger to an absorber of the refrigeration system when strong solution builds up in the generator to an undesirable level. The strong solution line and the conduit means are in heat exchange relationship with each other in the triple loop heat exchanger so that, during normal operation of the refrigeration system, heat is exchanged between the relatively hot, strong solution flowing through the strong solution line and the relatively cool, weak solution flowing through the conduit means. Also, the strong solution line and the bypass system are in heat exchange relationship in the triple loop heat exchanger so that if the normal flow path of relatively hot, strong solution flowing from the generator to an absorber is blocked, then this relatively, hot strong solution which will then be flowing through the bypass system in the triple loop heat exchanger, is brought into heat exchange relationship with any strong solution which may have solidified in the strong solution line in the triple loop heat exchanger to thereby aid in desolidifying any such solidified strong solution.

  20. Triple helix purification and sequencing

    DOEpatents

    Wang, R.; Smith, L.M.; Tong, X.E.

    1995-03-28

    Disclosed herein are methods, kits, and equipment for purifying single stranded circular DNA and then using the DNA for DNA sequencing purposes. Templates are provided with an insert having a hybridization region. An elongated oligonucleotide has two regions that are complementary to the insert and the oligo is bound to a magnetic anchor. The oligo hybridizes to the insert on two sides to form a stable triple helix complex. The anchor can then be used to drag the template out of solution using a magnet. The system can purify sequencing templates, and if desired the triple helix complex can be opened up to a double helix so that the oligonucleotide will act as a primer for further DNA synthesis. 4 figures.

  1. The decay of triple systems

    NASA Astrophysics Data System (ADS)

    Martynova, A. I.; Orlov, V. V.

    2014-10-01

    Numerical simulations have been carried out in the general three-body problem with equal masses with zero initial velocities, to investigate the distribution of the decay times T based on a representative sample of initial conditions. The distribution has a power-law character on long time scales, f( T) ∝ T - α , with α = 1.74. Over small times T < 30 T cr ( T cr is the mean crossing time for a component of the triple system), a series of local maxima separated by about 1.0 T cr is observed in the decay-time distribution. These local peaks correspond to zones of decay after one or a few triple encounters. Figures showing the arrangement of these zones in the domain of the initial conditions are presented.

  2. Ahmed glaucoma valve in post-penetrating-keratoplasty glaucoma: A critically evaluated prospective clinical study

    PubMed Central

    Panda, Anita; Prakash, Vadivelu Jaya; Dada, Tanuj; Gupta, Anoop Kishore; Khokhar, Sudarshan; Vanathi, Murugesan

    2011-01-01

    Aim: The aim was to evaluate the outcome of Ahmed glaucoma valve (AGV) in post-penetrating-keratoplasty glaucoma (PKPG). Materials and Methods: In this prospective study, 20 eyes of 20 adult patients with post-PKPG with intraocular pressure (IOP) >21 mmHg, on two or more antiglaucoma medications, underwent AG (model FP7) implantation and were followed up for a minimum of 6 months. Absolute success was defined as 5

  3. Novel method to avoid the open-sky condition in penetrating keratoplasty: covered cornea technique.

    PubMed

    Arslan, Osman S; Unal, Mustafa; Arici, Ceyhun; Cicik, Erdoğan; Mangan, Serhat; Atalay, Eray

    2014-09-01

    The aim of this study was to present a novel technique to avoid the open-sky condition in pediatric and adult penetrating keratoplasty (PK). Seventy-two eyes of 65 infants and children and 44 eyes of 44 adult patients were operated on using this technique. After trephining the recipient cornea up to a depth of 50% to 70%, the anterior chamber was entered at 1 point. Then, only a 2 clock hour segment of the recipient button was incised, and this segment was sutured to the recipient rim with a single tight suture. The procedure was repeated until the entire recipient button was excised and resutured. The donor corneal button was sutured to the recipient corneal rim. The sutures between the recipient button and the rim were then cut off, and the recipient button was drawn out. None of the patients operated on with this technique developed complications related to the open-sky condition. Visual acuities, graft failure rates, and endothelial cell loss were comparable with the findings of studies performed for conventional PK. The technique described avoids the open-sky condition during the entire PK procedure. Endothelial cell loss rates are acceptable.

  4. Reappraisal of the Arabia-India-Somalia triple junction kinematics

    NASA Astrophysics Data System (ADS)

    Fournier, Marc; Patriat, Philippe; Leroy, Sylvie

    2001-07-01

    We propose alternative kinematics for the Arabia-India-Somalia triple junction based on a re-interpretation of seismological and magnetic data. The new triple junction of the ridge-ridge-ridge type is located at the bend of the Sheba Ridge in the eastern gulf of Aden at 14.5°N and 56.4°E. The Owen fracture zone (Arabia-India boundary) is connected to the Sheba Ridge by an ultra-slow divergent boundary trending N80°E±10° marked by diffuse seismicity. The location of the Arabia-India rotation pole is constrained at 14.1°N and 71.2°E by fitting the active part of the Owen fracture zone with a small circle. The finite kinematics of the triple junction is inferred from the present-day kinematics. Since the inception of the accretion 15-18 Ma ago, the Sheba Ridge has probably receded ∼300 km at the expense of the Carlsberg Ridge which propagated northwestward in the gulf of Aden, while an ultra-slow divergent plate boundary developed between the Arabian and Indian plates. The overall geometry of the new triple junction is very similar to that of the Azores triple junction.

  5. Lamellar keratoplasty using position-guided surgical needle and M-mode optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Shin, Sungwon; Bae, Jung Kweon; Ahn, Yujin; Kim, Hyeongeun; Choi, Geonho; Yoo, Young-Sik; Joo, Choun-Ki; Moon, Sucbei; Jung, Woonggyu

    2017-12-01

    Deep anterior lamellar keratoplasty (DALK) is an emerging surgical technique for the restoration of corneal clarity and vision acuity. The big-bubble technique in DALK surgery is the most essential procedure that includes the air injection through a thin syringe needle to separate the dysfunctional region of the cornea. Even though DALK is a well-known transplant method, it is still challenged to manipulate the needle inside the cornea under the surgical microscope, which varies its surgical yield. Here, we introduce the DALK protocol based on the position-guided needle and M-mode optical coherence tomography (OCT). Depth-resolved 26-gage needle was specially designed, fabricated by the stepwise transitional core fiber, and integrated with the swept source OCT system. Since our device is feasible to provide both the position information inside the cornea as well as air injection, it enables the accurate management of bubble formation during DALK. Our results show that real-time feedback of needle end position was intuitionally visualized and fast enough to adjust the location of the needle. Through our research, we realized that position-guided needle combined with M-mode OCT is a very efficient and promising surgical tool, which also to enhance the accuracy and stability of DALK.

  6. Iridoplasty of fixed-dilated pupil (Urrets-Zavalia syndrome) after deep anterior lamellar keratoplasty

    PubMed Central

    Ntora, Efthalia; Ziakas, Nikolaos

    2017-01-01

    A 38-year-old woman with advanced keratoconus initially developed Urrets-Zavalia Syndrome (UZS) in the left eye after deep anterior lamellar keratoplasty. During the uneventful surgery, a 7-mm-wide pupil unresponsive to light was noticed. On the first postoperative day, intraocular pressure (IOP) was elevated up to 45 mmHg with shallow anterior chamber (AC). A peripheral iridotomy in 2 o’clock position was conducted and a fixed combination of brinzolamide 1% and timolol 0.5% was administered topically. In the subsequent postoperative period, IOP was successfully reduced, but the patient reported severe photophobia, glare, and decreased vision. Twelve months after surgery, her best-corrected visual acuity (BCVA) was 20/200, the fixed-dilated pupil persisted, iris was atrophic, and lens opacities were detected. She was submitted for phacoemulsification cataract surgery combined with iridoplasty using the closed chamber slipping suture technique. Three months after surgery, her BCVA was 20/25, pupil diameter remained stable at 4 mm, and glare symptoms were significantly reduced. A very adequate cosmetic outcome was also achieved. Iridoplasty in postkeratoplasty patient with unilateral UZS was effective in improving patient's visual function disability and restoring residual anisocoria. This technique can be applied as a single procedure or combined with another one for the management of UZS. PMID:29118500

  7. Combinatorial Effects of Lapatinib and Rapamycin in Triple-Negative Breast Cancer Cells

    PubMed Central

    Liu, Tongrui; Yacoub, Rami; Taliaferro-Smith, LaTonia D.; Sun, Shi-Yong; Graham, Tisheeka R.; Dolan, Ryan; Lobo, Christine; Tighiouart, Mourad; Yang, Lily; Adams, Amy; O'Regan, Ruth M.

    2016-01-01

    Triple-negative breast cancers, which lack estrogen receptor, progesterone receptor, and HER2/neu overexpression, account for approximately 15% of breast cancers, but occur more commonly in African Americans. The poor survival outcomes seen with triple-negative breast cancers patients are, in part, due to a lack of therapeutic targets. Epidermal growth factor receptor (EGFR) is overexpressed in 50% of triple-negative breast cancers, but EGFR inhibitors have not been effective in patients with metastatic breast cancers. However, mTOR inhibition has been shown to reverse resistance to EGFR inhibitors. We examined the combination effects of mTOR inhibition with EGFR inhibition in triple-negative breast cancer in vitro and in vivo. The combination of EGFR inhibition by using lapatinib and mTOR inhibition with rapamycin resulted in significantly greater cytotoxicity than the single agents alone and these effects were synergistic in vitro. The combination of rapamycin and lapatinib significantly decreased growth of triple-negative breast cancers in vivo compared with either agent alone. EGFR inhibition abrogated the expression of rapamycin-induced activated Akt in triple-negative breast cancer cells in vitro. The combination of EGFR and mTOR inhibition resulted in increased apoptosis in some, but not all, triple-negative cell lines, and these apoptotic effects correlated with a decrease in activated eukaryotic translation initiation factor (eIF4E). These results suggest that mTOR inhibitors could sensitize a subset of triple-negative breast cancers to EGFR inhibitors. Given the paucity of effective targeted agents in triple-negative breast cancers, these results warrant further evaluation. PMID:21690228

  8. [Implantation of a sulcus-fixated toric additive intraocular lens in a case of high astigmatism after a triple procedure].

    PubMed

    Linz, K; Auffarth, G U; Kretz, F T A

    2014-08-01

    Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D. A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, - 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and - 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to - 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed. Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of

  9. A triple point in 3-level systems

    NASA Astrophysics Data System (ADS)

    Nahmad-Achar, E.; Cordero, S.; López-Peña, R.; Castaños, O.

    2014-11-01

    The energy spectrum of a 3-level atomic system in the Ξ-configuration is studied. This configuration presents a triple point independently of the number of atoms, which remains in the thermodynamic limit. This means that in a vicinity of this point any quantum fluctuation will drastically change the composition of the ground state of the system. We study the expectation values of the atomic population of each level, the number of photons, and the probability distribution of photons at the triple point.

  10. Deep Laser-Assisted Lamellar Anterior Keratoplasty with Microkeratome-Cut Grafts

    PubMed Central

    Yokogawa, Hideaki; Tang, Maolong; Li, Yan; Liu, Liang; Chamberlain, Winston; Huang, David

    2016-01-01

    Background The goals of this laboratory study were to evaluate the interface quality in laser-assisted lamellar anterior keratoplasty (LALAK) with microkeratome-cut grafts, and to achieve good graft–host apposition. Methods Simulated LALAK surgeries were performed on six pairs of eye bank corneoscleral discs. Anterior lamellar grafts were precut with microkeratomes. Deep femtosecond (FS) laser cuts were performed on host corneas followed by excimer laser smoothing. Different parameters of FS laser cuts and excimer laser smoothing were tested. OCT was used to measure corneal pachymetry and evaluate graft-host apposition. The interface quality was quantified in a masked fashion using a 5-point scale based on scanning electron microscopy images. Results Deep FS laser cuts at 226–380 μm resulted in visible ridges on the host bed. Excimer laser smoothing with central ablation depth of 29 μm and saline as a smoothing agent did not adequately reduce ridges (score = 4.0). Deeper excimer laser ablation of 58 μm and Optisol-GS as a smoothing agent smoothed ridges to an acceptable level (score = 2.1). Same sizing of the graft and host cut diameters with an approximately 50 μm deeper host side-cut relative to the central graft thickness provided the best graft–host fit. Conclusions Deep excimer laser ablation with a viscous smoothing agent was needed to remove ridges after deep FS lamellar cuts. The host side cut should be deep enough to accommodate thicker graft peripheral thickness compared to the center. This LALAK design provides smooth lamellar interfaces, moderately thick grafts, and good graft-host fits. PMID:26890667

  11. The effect of donor diabetes history on graft failure and endothelial cell density 10 years after penetrating keratoplasty.

    PubMed

    Lass, Jonathan H; Riddlesworth, Tonya D; Gal, Robin L; Kollman, Craig; Benetz, Beth A; Price, Francis W; Sugar, Alan; Terry, Mark A; Soper, Mark; Beck, Roy W

    2015-03-01

    To examine the long-term effect of donor diabetes history on graft failure and endothelial cell density (ECD) after penetrating keratoplasty (PK) in the Cornea Donor Study. Multicenter, prospective, double-masked, controlled clinical trial. One thousand ninety subjects undergoing PK for a moderate risk condition, principally Fuchs' dystrophy or pseudophakic or aphakic corneal edema, were enrolled by 105 surgeons from 80 clinical sites in the United States. Corneas from donors 12 to 75 years of age were assigned by 43 eye banks to participants without respect to recipient factors. Donor and recipient diabetes status was determined from existing medical records. Images of the central endothelium were obtained before surgery (baseline) and at intervals for 10 years after surgery and were analyzed by a central image analysis reading center to determine ECD. Time to graft failure (regraft or cloudy cornea for 3 consecutive months) and ECD. There was no statistically significant association of donor diabetes history with 10-year graft failure, baseline ECD, 10-year ECD, or ECD values longitudinally over time in unadjusted analyses, nor after adjusting for donor age and other significant covariates. The 10-year graft failure rate was 23% in the 199 patients receiving a cornea from a donor with diabetes versus 26% in the 891 patients receiving a cornea from a donor without diabetes (95% confidence interval for the difference, -10% to 6%; unadjusted P=0.60). Baseline ECD (P=0.71), 10-year ECD (P>0.99), and changes in ECD over 10 years (P=0.86) were similar comparing donor groups with and without diabetes. The study results do not suggest an association between donor diabetes and PK outcome. However, the assessment of donor diabetes was imprecise and based on historical data only. The increasing frequency of diabetes in the aging population in the United States affects the donor pool. Thus, the impact of donor diabetes on long-term endothelial health after PK or endothelial

  12. The Effect of Donor Diabetes History on Graft Failure and Endothelial Cell Density Ten Years after Penetrating Keratoplasty

    PubMed Central

    Lass, Jonathan H.; Riddlesworth, Tonya D.; Gal, Robin L.; Kollman, Craig; Benetz, Beth A.; Price, Francis W.; Sugar, Alan; Terry, Mark A.; Soper, Mark; Beck, Roy W.

    2014-01-01

    Objective To examine the long term effect of donor diabetes history on graft failure and endothelial cell density (ECD) after penetrating keratoplasty (PKP) in the Cornea Donor Study Design Multi-center prospective, double-masked, controlled clinical trial Participants 1090 subjects undergoing PKP for a moderate risk condition, principally Fuchs’ dystrophy or pseudophakic/aphakic corneal edema (PACE), were enrolled by 105 surgeons from 80 clinical sites in the United States. Methods Corneas from donors 12 to 75 years old were assigned by 43 eye banks to participants without respect to recipient factors. Donor and recipient diabetes status was determined from existing medical records. Images of the central endothelium were obtained preoperatively (baseline) and at intervals for ten years postoperatively and analyzed by a central image analysis reading center to determine ECD. Main Outcome Measure(s) Time to graft failure (regraft or cloudy cornea for 3 consecutive months) and ECD. Results There was no statistically significant association of donor diabetes history with 10-year graft failure, baseline ECD, 10-year ECD or ECD values longitudinally over time in unadjusted analyses nor after adjusting for donor age and other significant covariates. The 10-year graft failure rate was 23% in the 199 cases receiving a cornea from a donor with diabetes versus 26% in the 891 cases receiving a cornea from a donor without diabetes (95% confidence interval for the difference: −10% to +6%; unadjusted p = 0.60). Baseline ECD (p=0.71), 10-year ECD (p>0.99), and changes in ECD over 10 years (p=0.86) were similar comparing donor diabetes and no-diabetes groups. Conclusions and Relevance The study results do not suggest an association between donor diabetes and PKP outcome. However, the assessment of donor diabetes was imprecise and based on historical data only. The increasing frequency of diabetes in the aging population in the United States affects the donor pool, thus the

  13. "Special Issue": Regional Dimensions of the Triple Helix Model

    ERIC Educational Resources Information Center

    Todeva, Emanuela; Danson, Mike

    2016-01-01

    This paper introduces the rationale for the special issue and its contributions, which bridge the literature on regional development and the Triple Helix model. The concept of the Triple Helix at the sub-national, and specifically regional, level is established and examined, with special regard to regional economic development founded on…

  14. A sliding technique to load thin endothelial donor lamella onto Busin glide for Descemet-stripping automated endothelial keratoplasty

    PubMed Central

    Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa

    2012-01-01

    We describe a modified technique for loading donor corneal endothelial lamella onto a Busin glide® without causing wrinkles, as part of the procedure of Descemet-stripping automated endothelial keratoplasty. Briefly, after punching out a composite of the donor-endothelial lamella and a microkeratome-dissected cap, several drops of dispersive ophthalmic viscosurgical device are placed onto the endothelial surface. The Busin glide surface is then wetted with several drops of balanced salt solution. After the composite is transferred onto the Busin glide, hydrodissection of the potential space between the donor-endothelial lamella and the microkeratome-dissected cap is carefully performed to enable smooth detachment of these two lamellae. Whereas simply dragging the donor-endothelial lamella directly onto the glide can cause wrinkling or folding of the donor lamella, this technique enables smooth detachment of the composite without wrinkle or fold formation, and results in less endothelial cell damage. PMID:22927732

  15. Coupling characteristics of the spun optical fiber with triple stress elements

    NASA Astrophysics Data System (ADS)

    Ji, Minning; Shang, Fengtao; Chen, Dandan

    2018-06-01

    An empirical formula related to the stress field distribution in the optical fiber with triple stress elements is proposed and proved. The possible intercoupling between the fundamental modes and the higher order modes is demonstrated. The transmission property of the spun optical fiber with triple stress elements is analyzed. The experimental data from a sample of the spun optical fiber with triple stress elements confirm the theoretical results very well.

  16. Fractal spectral triples on Kellendonk's C∗-algebra of a substitution tiling

    NASA Astrophysics Data System (ADS)

    Mampusti, Michael; Whittaker, Michael F.

    2017-02-01

    We introduce a new class of noncommutative spectral triples on Kellendonk's C∗-algebra associated with a nonperiodic substitution tiling. These spectral triples are constructed from fractal trees on tilings, which define a geodesic distance between any two tiles in the tiling. Since fractals typically have infinite Euclidean length, the geodesic distance is defined using Perron-Frobenius theory, and is self-similar with scaling factor given by the Perron-Frobenius eigenvalue. We show that each spectral triple is θ-summable, and respects the hierarchy of the substitution system. To elucidate our results, we construct a fractal tree on the Penrose tiling, and explicitly show how it gives rise to a collection of spectral triples.

  17. A tunable few electron triple quantum dot

    NASA Astrophysics Data System (ADS)

    Gaudreau, L.; Kam, A.; Granger, G.; Studenikin, S. A.; Zawadzki, P.; Sachrajda, A. S.

    2009-11-01

    In this paper, we report on a tunable few electron lateral triple quantum dot design. The quantum dot potentials are arranged in series. The device is aimed at studies of triple quantum dot properties where knowing the exact number of electrons is important as well as quantum information applications involving electron spin qubits. We demonstrate tuning strategies for achieving required resonant conditions such as quadruple points where all three quantum dots are on resonance. We find that in such a device resonant conditions at specific configurations are accompanied by complex charge transfer behavior.

  18. Targeting the androgen receptor in triple-negative breast cancer.

    PubMed

    Gucalp, Ayca; Traina, Tiffany A

    Triple-negative breast cancer represents approximately 15%-20% of all newly diagnosed breast cancers, but it accounts for a disproportionate number of breast cancer-related deaths each year. Owing to the lack of estrogen, progesterone, and human epidermal growth factor receptor 2 expression, patients with triple-negative breast cancer do not benefit from generally well-tolerated and effective therapies targeting the estrogen and human epidermal growth factor receptor 2 signaling pathways and are faced with an increased risk of disease progression and poorer overall survival. The heterogeneity of triple-negative breast cancer has been increasingly recognized and this may lead to therapeutic opportunities because of newly defined oncogenic drivers and targets. A subset of triple-negative breast tumors expresses the androgen receptor (AR) and this may benefit from treatments that inhibit the AR-signaling pathway. The first proof-of-concept trial established activity of the AR antagonist, bicalutamide, in patients with advanced AR+ triple-negative breast cancer. Since that time, evidence further supports the activity of other next-generation AR-targeted agents such as enzalutamide. Not unlike in estrogen receptor-positive breast cancer, mechanisms of resistance are being investigated and rationale exists for thoughtful, well-designed combination regimens such as AR antagonism with CDK4/6 pathway inhibitors or PI3K inhibitors. Furthermore, novel agents developed for the treatment of prostate cancer, which reduce androgen production such as abiraterone acetate and seviteronel, are being tested as well. This review summarizes the underlying biology of AR signaling in breast cancer development and the available clinical trial data for the use of anti-androgen therapy in the treatment of AR+ triple-negative breast cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Corrosion casts of big bubbles formed during deep anterior lamellar keratoplasty.

    PubMed

    Feizi, Sepehr; Kanavi, Mozhgan Rezaei; Kharaghani, Davood; Balagholi, Sahar; Meskinfam, Masoumeh; Javadi, Mohammad Ali

    2016-11-01

    To characterize the walls of big bubbles formed during deep anterior lamellar keratoplasty (DALK) using the corrosion casting technique. Fresh corneoscleral buttons with normal transparency and without any known eye diseases (n = 11) were obtained from 11 human donors. A 20-gauge needle was used to inject a solution of 20 % polyvinyl alcohol (PVA) immediately beneath the corneal endothelium to form big bubbles in eight corneoscleral buttons. In the second experiment on three corneoscleral buttons, a big bubble was first formed by air injection beneath the endothelium. Thereafter, 20 % PVA was injected into the bubble space. Scanning electron microscopy was used to characterize the surfaces of the casts, which replicated the walls of the big bubbles. A type-1 bubble was formed in all corneas. In one cornea, one type-1 bubble was initially formed centrally, and while it was enlarged, an eccentric type-2 bubble appeared. Scanning electron microscopy showed that the casts of type-1 bubbles had two distinct surfaces. The anterior surface demonstrated several holes or pits, depending on the material used for the bubble formation, whereas the posterior surface exhibited an uneven surface. The anterior and posterior surfaces of the type-2 cast were more or less similar. A communication measuring 531.9 µm in length and 171.4 µm in diameter was found between the two bubbles. The corrosion casting technique provides a permanent three-dimensional record of the potential spaces and barriers in the posterior corneal stroma, which explains several features associated with big-bubble DALK.

  20. Triple-band metamaterial absorption utilizing single rectangular hole

    NASA Astrophysics Data System (ADS)

    Kim, Seung Jik; Yoo, Young Joon; Kim, Young Ju; Lee, YoungPak

    2017-01-01

    In the general metamaterial absorber, the single absorption band is made by the single meta-pattern. Here, we introduce the triple-band metamaterial absorber only utilizing single rectangular hole. We also demonstrate the absorption mechanism of the triple absorption. The first absorption peak was caused by the fundamental magnetic resonance in the metallic part between rectangular holes. The second absorption was generated by induced tornado magnetic field. The process of realizing the second band is also presented. The third absorption was induced by the third-harmonic magnetic resonance in the metallic region between rectangular holes. In addition, the visible-range triple-band absorber was also realized by using similar but smaller single rectangular-hole structure. These results render the simple metamaterials for high frequency in large scale, which can be useful in the fabrication of metamaterials operating in the optical range.

  1. Targeting Histone Abnormality in Triple Negative Breast Cancer

    DTIC Science & Technology

    2015-08-01

    Casero RA, Davidson NE. Molecular mechanisms of polyamine analogues in cancer cells. Anti - Cancer Drugs, 16(3): 229-241, 2005. PMID: 15711175 18 3...1 AWARD NUMBER: W81XWH-14-1-0237 TITLE: Targeting Histone Abnormality in Triple-Negative Breast Cancer PRINCIPAL INVESTIGATOR: Yi...TITLE AND SUBTITLE 5a. CONTRACT NUMBER Targeting Histone Abnormality in Triple-Negative Breast Cancer 5b. GRANT NUMBER W81XWH-14-1-0237 5c

  2. Asteroid Systems: Binaries, Triples, and Pairs

    NASA Astrophysics Data System (ADS)

    Margot, J.-L.; Pravec, P.; Taylor, P.; Carry, B.; Jacobson, S.

    In the past decade, the number of known binary near-Earth asteroids has more than quadrupled and the number of known large main-belt asteroids with satellites has doubled. Half a dozen triple asteroids have been discovered, and the previously unrecognized populations of asteroid pairs and small main-belt binaries have been identified. The current observational evidence confirms that small (≲20 km) binaries form by rotational fission and establishes that the Yarkovsky-O'Keefe-Radzievskii-Paddack (YORP) effect powers the spin-up process. A unifying paradigm based on rotational fission and post-fission dynamics can explain the formation of small binaries, triples, and pairs. Large (>~20 km) binaries with small satellites are most likely created during large collisions.

  3. Incipient triple point for adsorbed xenon monolayers: Pt(111) versus graphite substrates

    NASA Astrophysics Data System (ADS)

    Novaco, Anthony D.; Bruch, L. W.; Bavaresco, Jessica

    2015-04-01

    Simulation evidence of an incipient triple point is reported for xenon submonolayers adsorbed on the (111) surface of platinum. This is in stark contrast to the "normal" triple point found in simulations and experiments for xenon on the basal plane surface of graphite. The motions of the atoms in the surface plane are treated with standard 2D "NVE" molecular dynamics simulations using modern interactions. The simulation evidence strongly suggests an incipient triple point in the 120 -150 K range for adsorption on the Pt (111) surface while the adsorption on graphite shows a normal triple point at about 100 K.

  4. Intramolecular triple helix as a model for regular polyribonucleotide (CAA)(n).

    PubMed

    Efimov, Alexander V; Spirin, Alexander S

    2009-10-09

    The regular (CAA)(n) polyribonucleotide, as well as the omega leader sequence containing (CAA)-rich core, have recently been shown to form cooperatively melted and compact structures. In this report, we propose a structural model for the (CAA)(n) sequence in which the polyribonucleotide chain is folded upon itself, so that it forms an intramolecular triple helix. The triple helix is stabilized by hydrogen bonding between bases thus forming coplanar triads, and by stacking interactions between the base triads. A distinctive feature of the proposed triple helix is that it does not contain the canonical double-helix elements. The difference from the known triple helices is that Watson-Crick hydrogen bond pairings do not take place in the interactions between the bases within the base triads.

  5. Penetrating Keratoplasty at a Tertiary Referral Center in Ethiopia: Indications and Outcomes.

    PubMed

    Ayalew, Menen; Tilahun, Yonas; Holsclaw, Doug; Indaram, Maanasa; Stoller, Nicole E; Keenan, Jeremy D; Rose-Nussbaumer, Jennifer

    2017-06-01

    To describe the indications, visual acuity outcomes, and graft survival after penetrating keratoplasty (PKP) in Addis Ababa, Ethiopia. The medical records of patients who underwent PKP at Menelik II Hospital between September 2000 and September 2013 were retrospectively reviewed. The prespecified outcomes were graft survival, visual acuity, and complication rates. A total of 321 patients underwent PKP during the study period and were included in the analysis. Indications for surgery were trachoma or leukoma in 141 (44%), keratoconus in 45 (14%), corneal dystrophy in 46 (14%), pseudophakic or aphakic bullous keratopathy in 28 (9%), trauma in 27 (8%), previous graft failure in 18 (6%), active ulcer, burn, or perforation in 9 (3%), and others in 7 (2%). The graft survival rate was 80% overall at 2 years but varied considerably depending on the indication for surgery. Uncorrected visual acuity improved from baseline mean logarithm of the minimum angle of resolution 2.09 (SD 0.67) to mean logarithm of the minimum angle of resolution of 1.53 (SD 1.03) at 2 years. A number of factors affected the visual acuity outcomes. Patients were not routinely refracted, and only 18% (N = 60) of patients had access to corrective spectacles or contact lenses postoperatively. Complication rates were high with infectious keratitis being the most common. PKP is becoming a viable treatment for corneal opacity in developing countries. However, the high burden of disease and lack of corrective lenses remain significant obstacles to overcome.

  6. Triple p-positive parenting program for mothers of ADHD children.

    PubMed

    Aghebati, Asma; Gharraee, Banafsheh; Hakim Shoshtari, Mitra; Gohari, Mahmood Reza

    2014-01-01

    Attention deficit hyperactivity disorder (ADHD) is a chronic, highly prevalent neurodevelopmental disorder which affects 9% of school-age children. Triple P-Positive Parenting Program is an evidence-based parenting program reported to be useful in the management of this disorder. The aim of this randomized controlled trial was to evaluate the effectiveness of Triple P in mothers of ADHD children. In this study, 30 mothers with ADHD children aged between 6 to 10 were randomly assigned to two groups (15 participants in each group). Parenting style, mother-child relationship, maternal depression, anxiety and stress, and children's behavioral problems were evaluated. The intervention group received 120 minute sessions for 5 weeks and 15-30 minute telephone contacts for 3 weeks while no intervention was done for the control group. Analysis of covariance revealed that mothers of the Triple P group showed significant (p < 0.01) improvements in parenting style, mother-child relationship, and considerable decrease in depression, anxiety and stress. Women trained in the Triple P group also reported significantly lower rates of child misbehavior than women of the control group. Triple P-Positive Parenting intervention is effective and acceptable for mothers of ADHD children. None. Clinical Trial Registration-URL: http://www.irct.ir. Unique identifier: IRCT201111288234N1.

  7. Diamond knife-assisted deep anterior lamellar keratoplasty to manage keratoconus.

    PubMed

    Vajpayee, Rasik B; Maharana, Prafulla K; Sharma, Namrata; Agarwal, Tushar; Jhanji, Vishal

    2014-02-01

    To evaluate the outcomes of a new surgical technique, diamond knife-assisted deep anterior lamellar keratoplasty (DALK), and compare its visual and refractive results with big-bubble DALK in cases of keratoconus. Tertiary eyecare hospital. Comparative case series. The visual and surgical outcomes of diamond knife-assisted DALK were compared with those of successful big-bubble DALK. Diamond knife-assisted DALK was performed in 19 eyes and big-bubble DALK, in 11 eyes. All surgeries were completed successfully. No intraoperative or postoperative complications occurred with diamond knife-assisted DALK. Six months after diamond knife-assisted DALK, the mean corrected distance visual acuity (CDVA) improved significantly from 1.87 logMAR ± 0.22 (SD) to 0.23 ± 0.06 logMAR, the mean keratometry improved from 65.99 ± 8.86 diopters (D) to 45.13 ± 1.16 D, and the mean keratometric cylinder improved from 7.99 ± 3.81 D to 2.87 ± 0.59 D (all P=.005). Postoperatively, the mean refractive astigmatism was 2.55 ± 0.49 D and the mean spherical equivalent was -1.97 ± 0.56 D. The mean logMAR CDVA (P = .06), postoperative keratometry (P=.64), refractive cylinder (P=.63), and endothelial cell loss (P=.11) were comparable between diamond knife-assisted DALK and big-bubble DALK. Diamond knife-assisted DALK was effective and predictable as a surgical technique for management of keratoconus cases. This technique has the potential to offer visual and refractive outcomes comparable to those of big-bubble DALK. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Changing indications for lamellar keratoplasty in Shandong, 1993 - 2008.

    PubMed

    Qu, Li-jun; Xie, Li-xin

    2010-11-01

    With the advancement of microsurgical techniques, lamellar keratoplasty (LK) has been more valued and performed to treat corneal blindness. This study aimed to evaluate the indications and changing trends for LK during the past 16 years in Shandong Eye Institute, an eye center in China. A total of 1529 eyes, predominantly from male (70.7%) patients undergoing LK between January 1993 and December 2008, were enrolled in this study. Data were collected by reviewing patient medical records for demographic characteristics, clinical diagnosis, laboratory findings and risk factors. Surgical times, initial diagnoses and causes of regrafting were recorded. All LKs were sequentially divided into period 1 (from 1993 to 2000) and period 2 (from 2001 to 2008). Rural-dwelling patients in this study numbered 1089 (71.2%); in all cases of infectious keratitis, rural patients accounted for 90.5%. The leading indications for LK were infectious keratitis (31.0%), corneal trauma (21.1%), keratoconus (18.7%), corneal dystrophy and degeneration (7.3%), regrafting (7.1%), immunologic disorders (6.7%), congenital abnormalities and corneal tumor (4.1%) and corneal scarring (3.1%). The most common subcategory of infectious keratitis was fungal keratitis (67.5%). Fusarium solani was the most morbigenous fungi. Among the patients, 73.1% of thermal burns were caused by hot molten metal, and 47.8% of alkali burns by lime. Dermoid was the most common indication for congenital abnormalities. The two main initial diagnoses from 109 regrafting cases were corneal trauma (45.9%) and Mooren's ulcer (27.5%). The most common cause for regrafting was immune rejection (35.8%). Infectious keratitis was the most common indication for LK from 16.0% in period 1 to 41.1% in period 2, followed by keratoconus (16.8%) and corneal trauma (14.5%). During the past 16 years, there have been major changes in the constituent ratios of leading indications for LK in Shangdong. Infectious keratitis has become the most

  9. Interface Fluid Syndrome After Laser In Situ Keratomileusis (LASIK) Because of Fuchs Endothelial Dystrophy Reversed by Descemet Membrane Endothelial Keratoplasty (DMEK).

    PubMed

    Luceri, Salvatore; Baksoellah, Zainab; Ilyas, Abbas; Baydoun, Lamis; Melles, Gerrit R J

    2016-12-01

    To describe a case that developed "interface fluid syndrome" after previous laser in situ keratomileusis (LASIK) because of Fuchs endothelial dystrophy (FED), which was reversed by Descemet membrane endothelial keratoplasty (DMEK). A 58-year-old male patient presented with bilateral visual impairment owing to FED and visually significant cataract. Cataract surgery was carried out in both eyes followed by DMEK in his left eye. After cataract surgery, visual acuity did not improve sufficiently because corneal thickness increased and a fine cleft with interface fluid developed between the LASIK-flap and the residual stromal bed. After uneventful DMEK in his left eye, the fluid resolved within a week and visual acuity improved rapidly. This case demonstrates that "interface fluid syndrome" after LASIK caused by concomitant endothelial dysfunction may be reversed by DMEK allowing fast visual recovery.

  10. Bacterial collagen-like proteins that form triple-helical structures

    PubMed Central

    Yu, Zhuoxin; An, Bo; Ramshaw, John A.M.; Brodsky, Barbara

    2014-01-01

    A large number of collagen-like proteins have been identified in bacteria during the past ten years, principally from analysis of genome databases. These bacterial collagens share the distinctive Gly-Xaa-Yaa repeating amino acid sequence of animal collagens which underlies their unique triple-helical structure. A number of the bacterial collagens have been expressed in E. coli, and they all adopt a triple-helix conformation. Unlike animal collagens, these bacterial proteins do not contain the post-translationally modified amino acid, hydroxyproline, which is known to stabilize the triple-helix structure and may promote self-assembly. Despite the absence of collagen hydroxylation, the triple-helix structures of the bacterial collagens studied exhibit a high thermal stability of 35–39 °C, close to that seen for mammalian collagens. These bacterial collagens are readily produced in large quantities by recombinant methods, either in the original amino acid sequence or in genetically manipulated sequences. This new family of recombinant, easy to modify collagens could provide a novel system for investigating structural and functional motifs in animal collagens and could also form the basis of new biomedical materials with designed structural properties and functions. PMID:24434612

  11. Defining Genomic Changes in Triple-Negative Breast Cancer in Women of African Descent

    DTIC Science & Technology

    2012-06-01

    African and African - American breast cancer cases. Gene Expression Array Studies The 31 triple negative Kijabe samples were... American Adjacent Normal Breast Tissue PI: Pegram & Baumbach Defining Genomic Changes in Triple Negative Breast Cancer in Women of African ...Tissues from African - American and East African Patients with Triple Negative Breast

  12. A Study of Neoadjuvant Paclitaxel in Combination With Bavituximab in Early- Stage Triple- Negative Breast Cancer

    ClinicalTrials.gov

    2017-03-08

    Breast Cancer; Triple Negative Breast Neoplasms; Triple-Negative Breast Neoplasm; Triple-Negative Breast Cancer; Triple Negative Breast Cancer; ER-Negative PR-Negative HER2-Negative Breast Neoplasms; ER-Negative PR-Negative HER2-Negative Breast Cancer

  13. EURAMET.T-K7 Key Comparison of Water Triple-Point Cells

    NASA Astrophysics Data System (ADS)

    Peruzzi, A.; Bosma, R.; Kerkhof, O.; Rosenkranz, P.; Del Campo Maldonado, M. D.; Strnad, R.; Nielsen, J.; Anagnostou, M.; Veliki, T.; Zvizdic, D.; Grudnewicz, E.; Nedea, M.; Neagu, D. M.; Steur, P.; Filipe, E.; Lobo, I.; Antonsen, I.; Renaot, E.; Heinonen, M.; Weckstrom, T.; Bojkovski, J.; Turzo-Andras, E.; Nemeth, S.; White, M.; Tegeler, E.; Dobre, M.; Duris, S.; Kartal Dogan, A.; Uytun, A.; Augevicius, V.; Pauzha, A.; Pokhodun, A.; Simic, S.

    2011-12-01

    The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the "mother" comparison CCT-K7 is discussed in detail.

  14. Does Lactation Mitigate Triple Negative/Basal Breast Cancer Progression?

    DTIC Science & Technology

    2012-09-01

    201 – 31 August 201 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER DOES LACTATION MITIGATE TRIPLE NEGATIVE /BASAL BREAST CANCER PROGRESSION? 5b...25 1 INTRODUCTION Young African American women have an increased risk of developing aggressive forms of breast cancer (i.e... triple negative /basal-like) than young non-Hispanic white women. Recent epidemiological data show increased risk of basal-like breast cancer with

  15. Polygonal Triples and the Double Ruling of a Hyperboloid

    ERIC Educational Resources Information Center

    Yiu, Paul

    2012-01-01

    For a given positive integer k [not equal] 4, let "P[subscript k,n]" denote the "n"-th "k"-gonal number. We study "k"-gonal triples ("a", "b", "c") satisfying P[subscript k,a] + P[subscript k,b] = P[subscript k,c]. A "k"-gonal triple corresponds to a rational point on the rectangular hyperboloid x[squared] + y[squared] = z[squared] + 1. The simple…

  16. Common breast cancer susceptibility loci are associated with triple negative breast cancer

    PubMed Central

    Stevens, Kristen N.; Vachon, Celine M.; Lee, Adam M.; Slager, Susan; Lesnick, Timothy; Olswold, Curtis; Fasching, Peter A.; Miron, Penelope; Eccles, Diana; Carpenter, Jane E.; Godwin, Andrew K.; Ambrosone, Christine; Winqvist, Robert; Schmidt, Marjanka K.; Cox, Angela; Cross, Simon S.; Sawyer, Elinor; Hartmann, Arndt; Beckmann, Matthias W.; Schulz-Wendtland, Rüdiger; Ekici, Arif B.; Tapper, William J; Gerty, Susan M; Durcan, Lorraine; Graham, Nikki; Hein, Rebecca; Nickels, Stephan; Flesch-Janys, Dieter; Heinz, Judith; Sinn, Hans-Peter; Konstantopoulou, Irene; Fostira, Florentia; Pectasides, Dimitrios; Dimopoulos, Athanasios M.; Fountzilas, George; Clarke, Christine L.; Balleine, Rosemary; Olson, Janet E.; Fredericksen, Zachary; Diasio, Robert B.; Pathak, Harsh; Ross, Eric; Weaver, JoEllen; Rüdiger, Thomas; Försti, Asta; Dünnebier, Thomas; Ademuyiwa, Foluso; Kulkarni, Swati; Pylkäs, Katri; Jukkola-Vuorinen, Arja; Ko, Yon-Dschun; Van Limbergen, Erik; Janssen, Hilde; Peto, Julian; Fletcher, Olivia; Giles, Graham G.; Baglietto, Laura; Verhoef, Senno; Tomlinson, Ian; Kosma, Veli-Matti; Beesley, Jonathan; Greco, Dario; Blomqvist, Carl; Irwanto, Astrid; Liu, Jianjun; Blows, Fiona M.; Dawson, Sarah-Jane; Margolin, Sara; Mannermaa, Arto; Martin, Nicholas G.; Montgomery, Grant W; Lambrechts, Diether; dos Santos Silva, Isabel; Severi, Gianluca; Hamann, Ute; Pharoah, Paul; Easton, Douglas F.; Chang-Claude, Jenny; Yannoukakos, Drakoulis; Nevanlinna, Heli; Wang, Xianshu; Couch, Fergus J.

    2012-01-01

    Triple negative breast cancers are an aggressive subtype of breast cancer with poor survival, but there remains little known about the etiological factors which promote its initiation and development. Commonly inherited breast cancer risk factors identified through genome wide association studies (GWAS) display heterogeneity of effect among breast cancer subtypes as defined by estrogen receptor (ER) and progesterone receptor (PR) status. In the Triple Negative Breast Cancer Consortium (TNBCC), 22 common breast cancer susceptibility variants were investigated in 2,980 Caucasian women with triple negative breast cancer and 4,978 healthy controls. We identified six single nucleotide polymorphisms (SNPs) significantly associated with risk of triple negative breast cancer, including rs2046210 (ESR1), rs12662670 (ESR1), rs3803662 (TOX3), rs999737 (RAD51L1), rs8170 (19p13.11) and rs8100241 (19p13.11). Together, our results provide convincing evidence of genetic susceptibility for triple negative breast cancer. PMID:21844186

  17. Effect of sterically demanding substituents on the conformational stability of the collagen triple helix.

    PubMed

    Erdmann, Roman S; Wennemers, Helma

    2012-10-17

    The effect of sterically demanding groups at proline residues on the conformational stability of the collagen triple helix was examined. The thermal stabilities (T(m) and ΔG) of eight different triple helices derived from collagen model peptides with (4R)- or (4S)-configured amidoprolines bearing either methyl or bulkier tert-butyl groups in the Xaa or Yaa position were determined and served as a relative measure for the conformational stability of the corresponding collagen triple helices. The results show that sterically demanding substituents are tolerated in the collagen triple helix when they are attached to (4R)-configured amidoprolines in the Xaa position or to (4S)-configured amidoprolines in the Yaa position. Structural studies in which the preferred conformation of (4R)- or (4S)-configured amidoproline were overlaid with the Pro and Hyp residues within a crystal structure of collagen revealed that the sterically demanding groups point to the outside of these two triple helices and thereby do not interfere with the formation of the triple helix. In all of the other examined collagen derivatives with lower stability of the triple helices, the acetyl or pivaloyl residues point toward the inside of the triple helix and clash with a residue of the neighboring strand. The results also revealed that unfavorable steric dispositions affect the conformational stability of the collagen triple helix more than unfavorable ring puckers of the proline residues. The results are useful for the design of functionalized collagen based materials.

  18. Regional Dimensions of the Triple Helix Model: Setting the Context

    ERIC Educational Resources Information Center

    Todeva, Emanuela; Danson, Mike

    2016-01-01

    This paper introduces the rationale for the special issue and its contributions, which bridge the literature on regional development and the Triple Helix model. The concept of the Triple Helix at the sub-national, and specifically regional, level is established and examined, with special regard to regional economic development founded on…

  19. A Triple Crater

    NASA Image and Video Library

    2017-06-01

    This image from NASA's Mars Reconnaissance Orbiter shows an elongated depression from three merged craters. The raised rims and ejecta indicate that these are impact craters rather than collapse or volcanic landforms. The pattern made by the ejecta and the craters suggest this was a highly oblique (low angle to the surface) impact, probably coming from the west. There may have been three major pieces flying in close formation to make this triple crater. https://photojournal.jpl.nasa.gov/catalog/PIA21652

  20. ACA and the Triple Aim: Musings of a Health Care Actuary.

    PubMed

    McCarthy, Mac

    2015-01-01

    In 2008, the Institute for Healthcare Improvement (IHI) promulgated the Triple Aim, which advocates simultaneous improvements in patient experiences, improved population health and lower cost per capita. In 2010, the Patient Protection and Affordable Care Act (ACA) promised quality, affordable health care for all Americans. It's fair to assume that the framers of ACA were aware of the Triple Aim, and it is likely that much of ACA was heavily influenced by IHI's positions. So it is reasonable, from time to time, to assess ACA's impact on health care against the Triple Aim principles.

  1. Residual corneal stroma in big-bubble deep anterior lamellar keratoplasty: a histological study in eye-bank corneas.

    PubMed

    McKee, Hamish D; Irion, Luciane C D; Carley, Fiona M; Jhanji, Vishal; Brahma, Arun K

    2011-10-01

    To determine if residual corneal stroma remains on the recipient posterior lamella in big-bubble deep anterior lamellar keratoplasty (DALK). Pneumodissection using the big-bubble technique was carried out on eye-bank corneas mounted on an artificial anterior chamber. Samples that had a successful big-bubble formation were sent for histological evaluation to determine if any residual stroma remained on the Descemet membrane (DM). Big-bubble formation was achieved in 32 donor corneas. Two distinct types of big-bubble were seen: the bubble had either a white margin (30 corneas) or a clear margin (two corneas). The posterior lamellae of all the white margin corneas showed residual stroma on DM with a mean central thickness of 7.0 μm (range 2.6-17.4 μm). The clear margin corneas showed no residual stroma on DM. It should no longer be assumed that big-bubble DALK, where the bubble has a white margin, routinely bares DM. True baring of DM may only occur with the less commonly seen clear margin bubble.

  2. Is Three a Crowd? Exploring the Development and Satisfaction of Students in Triples

    ERIC Educational Resources Information Center

    Long, Larry D.; Kujawa, Kyle

    2015-01-01

    Tripling, the assignment of a third resident to a room designed for two, is a common practice at many colleges and universities across the United States. Most of the research on tripling was conducted three or four decades ago, and research exploring how living in a triple affects the educational gains and satisfaction of college students is…

  3. Effect of disagreement between refractive, keratometric, and topographic determination of astigmatic axis on suture removal after penetrating keratoplasty

    PubMed Central

    Sarhan, A; Dua, H.; Beach, M.

    2000-01-01

    BACKGROUND/AIMS—Post-keratoplasty astigmatism can be managed by selective suture removal in the steep axis. Corneal topography, keratometry, and refraction are used to determine the steep axis for suture removal. However, often there is a disagreement between the topographically determined steep axis and sutures to be removed and that determined by keratometry and refraction. The purpose of this study was to evaluate any difference in the effect of suture removal, on visual acuity and astigmatism, in patients where such a disagreement existed.
METHODS—37 cases (from 37 patients) of selective suture removal after penetrating keratoplasty, were included. In the first group "the disagreement group" (n=15) there was disagreement between corneal topography, keratometry, and refraction regarding the axis of astigmatism and sutures to be removed. In the second group "the agreement group" (n=22) there was agreement between corneal topography, keratometry, and refraction in the determination of the astigmatic axis and sutures to be removed. Sutures were removed according to the corneal topography, at least 5 months postoperatively. Vector analysis for change in astigmatism and visual acuity after suture removal was compared between groups.
RESULTS—In the disagreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism after suture removal was 3.45 (SD 2.34), 3.57 (1.63), and 2.83 (1.68) dioptres, respectively. In the agreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism was 5.95 (3.52), 5.37 (3.29), and 4.71 (2.69) dioptres respectively. This difference in the vector corrected change in astigmatism between groups was statistically significant, p values of 0.02, 0.03, and 0.03 respectively. Visual acuity changes were more favourable in the agreement group. Improvement or no change in visual acuity occurred in 90.9% in the agreement group compared

  4. Solution Patterns Predicting Pythagorean Triples

    ERIC Educational Resources Information Center

    Ezenweani, Ugwunna Louis

    2013-01-01

    Pythagoras Theorem is an old mathematical treatise that has traversed the school curricula from secondary to tertiary levels. The patterns it produced are quite interesting that many researchers have tried to generate a kind of predictive approach to identifying triples. Two attempts, namely Diophantine equation and Brahmagupta trapezium presented…

  5. Structural insights into the stabilization of MALAT1 noncoding RNA by a bipartite triple helix

    PubMed Central

    Brown, Jessica A.; Bulkley, David; Wang, Jimin; Valenstein, Max L.; Yario, Therese A.; Steitz, Thomas A.; Steitz, Joan A.

    2014-01-01

    Metastasis-associated lung adenocarcinoma transcript 1 (MALAT1) is a highly-abundant nuclear long noncoding RNA that promotes malignancy. A 3′-stem-loop structure is predicted to confer stability by engaging a downstream A-rich tract in a triple helix, similar to the expression and nuclear retention element (ENE) from the KSHV polyadenylated nuclear RNA. The 3.1-Å resolution crystal structure of the human MALAT1 ENE and A-rich tract reveals a bipartite triple helix containing stacks of five and four U•A-U triples separated by a C+•G-C triplet and C-G doublet, extended by two A-minor interactions. In vivo decay assays indicate that this blunt-ended triple helix, with the 3′ nucleotide in a U•A-U triple, inhibits rapid nuclear RNA decay. Interruption of the triple helix by the C-G doublet induces a “helical reset” that explains why triple-helical stacks longer than six do not occur in nature. PMID:24952594

  6. Organizing product innovation: hierarchy, market or triple-helix networks?

    PubMed

    Fitjar, Rune Dahl; Gjelsvik, Martin; Rodríguez-Pose, Andrés

    This paper assesses the extent to which the organization of the innovation effort in firms, as well as the geographical scale at which this effort is pursued, affects the capacity to benefit from product innovations. Three alternative modes of organization are studied: hierarchy, market and triple-helix-type networks. Furthermore, we consider triple-helix networks at three geographical scales: local, national and international. These relationships are tested on a random sample of 763 firms located in five urban regions of Norway which reported having introduced new products or services during the preceding 3 years. The analysis shows that firms exploiting internal hierarchy or triple-helix networks with a wide range of partners managed to derive a significantly higher share of their income from new products, compared to those that mainly relied on outsourcing within the market. In addition, the analysis shows that the geographical scale of cooperation in networks, as well as the type of partner used, matters for the capacity of firms to benefit from product innovation. In particular, firms that collaborate in international triple-helix-type networks involving suppliers, customers and R&D institutions extract a higher share of their income from product innovations, regardless of whether they organize the processes internally or through the network.

  7. Synthesis of triple-stranded complexes using bis(dipyrromethene) ligands.

    PubMed

    Zhang, Zhan; Dolphin, David

    2010-12-20

    The reaction of an α-free, β,β'-linked bis(dipyrromethene) ligand with Fe(3+) or Co(3+) led to noninterconvertible triple-stranded helicates and mesocates. In the present context, a stable α-free ligand 2 has been developed and complexation of ligands 1 and 2 with diamagnetic Co(3+), Ga(3+), and In(3+) has been studied. The triple-stranded M(2)1(3) (M = Ga, In) and M(2)2(3) (M = Co, Ga, In) complexes were characterized using matrix-assisted laser desorption ionization time-of-flight spectrometry, (1)H NMR and UV-vis spectroscopy, and X-ray crystallography. Again, the (1)H NMR analysis showed that both the triple-stranded helicates and mesocates were generated in this metal-directed assembly. Consistent with our previous finding on coordinatively inert Co(3+) complexes, variable-temperature NMR spectroscopy indicated that the triple-stranded helicate and mesocate of labile In(3+) did not interconvert in solution, either. However, the diastereoselectivity of the M(2)2(3) complexes was found to improve with an increase in the reaction temperature. Taken together, this study complements the coordination chemistry of poly(dipyrromethene) ligands and provides further insight into the formation of helicates versus mesocates.

  8. Performance of Mercury Triple-Point Cells Made in Brazil

    NASA Astrophysics Data System (ADS)

    Petkovic, S. G.; Santiago, J. F. N.; Filho, R. R.; Teixeira, R. N.; Santos, P. R. F.

    2003-09-01

    Fixed-points cells are primary standards in ITS-90. They contain reference material with a purity of 99.999 % or more. The gallium in a melting-point cell, for example, can reach a purity of 99.99999 %. This level of purity is not easy to obtain. However, substances like water and mercury can be purified by means of distillation and chemical procedures. This paper presents the results of mercury triple-point cells made in Brazil that were directly compared to a mercury triple-point cell of 99.999% purity. This reference cell, made by Isotech (England), was previously compared to cells from CENAM (Mexico) and NRC (Canada) and the maximum deviation found was approximately 0.4 mK. The purification stage started with a sample of mercury 99.3 % pure, and the repeated use of both mechanical and chemical processes led to a purification grade considered good enough for calibration of standard platinum resistance thermometers. The purification procedures, the method of construction of the cell, the laboratory facilities, the comparison results and the budget of uncertainties are described in this paper. All of the cells tested have a triple-point temperature within 0.25 mK of the triple-point temperature of the Inmetro reference cell.

  9. Measuring ocular characteristics after gel injection adjustable keratoplasty (GIAK) in the rabbit

    NASA Astrophysics Data System (ADS)

    Comander, Jason I.; Parel, Jean-Marie A.; Simon, Gabriel; Takesue, Yoshiko; Villain, Franck L.

    1995-05-01

    Gel Injection Adjustable Keratoplasty (GIAK) is a refractive surgery procedure which uses an ocular ring implant made of a polyethylene oxide hydrogel to cause a refractive change in the cornea. Unlike laser photo refractive keratectomy, GIAK does not interfere with the central cornea because the ring lies around the optical axis. Thus, vision can be assessed immediately after surgery. Our in vivo study was designed to quantify GIAK's effects on tissues, the biocompatibility of the polymer and in the process investigate which ocular changes in the rabbit model can be monitored with precision using current technology. Thirty-two young rabbits underwent a delamination in one eye, 22 of which were injected with a new polymeric gel. Corneal topography, keratometry, pachymetry, and tonometry were performed on both eyes for up to 105 days. All corneas flattened with growth. In GIAK animals, we found an average flattening of 6.51 +/- 1.23 diopters (p < 0.0001) relative to the fellow eye. No statistically significant regression over the 102 days was observed. Intraocular pressure dropped slightly by 0.69 +/- 1.21 mmHg (p equals 0.025), a clinically insignificant value, while no significant change was detected in corneal thickness. Keratometry can be tracked in rabbits after GIAK surgery from POD 1. Measuring unoperated fellow eyes allows for the effects of surgery to be assessed without bias from growth. Using this protocol, GIAK was shown to be stable. It was more difficult to draw conclusions from pachymetry, tonometry, and topography data.

  10. Triple-effect absorption chiller cycle: A step beyond double-effect cycles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVault, R.C.

    1990-01-01

    Many advanced'' absorption cycles have been proposed during the current century. Of the hundreds of absorption cycles which have been patented throughout the world, all commercially manufactured products for air conditioning buildings have been variations of just two basic absorption cycles: single-effect and condenser-coupled double-effect cycles. The relatively low cooling coefficients of performance (COPs) inherent in single-effect and double-effect cycles limits the economic applicability of absorption air conditioners (chillers) in the United States. A triple-effect absorption chiller cycle is discussed. This cycle uses two condensers and two absorbers to achieve the triple effect.'' Depending on the absorption fluids selected, thismore » triple-effect cycle is predicted to improve cooling COPs by 18% to 60% compared with the equivalent double-effect cycle. This performance improvement is obtained without increasing the total amount of heat-transfer surface area needed for the heat exchangers. A comparison between the calculated performances of a double-effect cycle and a triple-effect cycle (both using ammonia-water (NH{sub 3}/H{sub 2}O) as the absorption fluid pair) is presented. The triple-effect cycle is predicted to have an 18% higher cooling COP (1.41 compared with 1.2 for a double-effect), lower pressure (47.70 atm (701 psi) instead of 68.05 atm (1000 psi)), significantly reduced pumping power (less than one-half that of the double-effect cycle), and potentially lower construction cost (33% less total heat exchange needed). Practical implications for this triple-effect cycle are discussed. 16 refs., 5 figs., 1 tab.« less

  11. Endophthalmitis after descemet stripping endothelial keratoplasty with concave-oriented dislocation on slit-lamp optical coherence topography.

    PubMed

    Kaiura, Terry L; Ritterband, David C; Koplin, Richard S; Shih, Carolyn; Palmierto, Pat M; Seedor, John A

    2010-02-01

    To present the first reported case of Descemet membrane stripping endothelial keratoplasty (DSEK)-associated endophthalmitis with concave dislocation on slit-lamp optical coherence topography (SL-OCT). An 86-year-old man underwent DSEK for corneal decompensation secondary to prior surgery. On all postoperative visits, a slit-lamp examination and SL-OCT were performed. On the first postoperative day, the lenticle was dislocated in a concave configuration as imaged with the SL-OCT. On the second postoperative day, the patient had eye pain, nausea, and increased intraocular pressure. On SL-OCT imaging, the concave configuration and fibrin stranding were imaged. With intraocular pressure lowering, the patient's pain subsided, and he was scheduled for a lenticle refloat the following day. The next day, endophthalmitis was diagnosed secondary to exuberant purulent inflammation. At surgery, the lenticle was removed, cultures were obtained, and pars plana vitrectomy and intravitreal injections were administered. Intraoperative cultures were positive for heavy growth of Streptococcus pneumoniae. Endophthalmitis is a potential complication for any intraocular procedure including DSEK. SL-OCT imaging postoperatively may reveal concave lenticle configuration and subtle anterior chamber fibrin stranding may be early sign of endophthalmitis.

  12. A Two-Piece Microkeratome-Assisted Mushroom Keratoplasty Improves the Outcomes and Survival of Grafts Performed in Eyes with Diseased Stroma and Healthy Endothelium (An American Ophthalmological Society Thesis)

    PubMed Central

    Busin, Massimo; Madi, Silvana; Scorcia, Vincenzo; Santorum, Paolo; Nahum, Yoav

    2015-01-01

    Purpose: To test the hypothesis that a new microkeratome-assisted penetrating keratoplasty (PK) technique employing transplantation of a two-piece mushroom-shaped graft may result in better visual outcomes and graft survival rates than those of conventional PK. Methods: Retrospective chart review of 96 eyes at low risk and 76 eyes at high risk for immunologic rejection (all with full-thickness central corneal opacity and otherwise healthy endothelium) undergoing mushroom PK between 2004 and 2012 at our Institution. Outcome measures were best-corrected visual acuity (BCVA), refraction, corneal topography, endothelial cell density, graft rejection, and survival probability. Results: Five years postoperatively, BCVA of 20/40 and 20/20 was recorded in 100% and over 50% of eyes, respectively. Mean spherical equivalent of refractive error did not vary significantly over a 5-year period; astigmatism averaged always below 4 diopters, with no statistically significant change over time, and was of the regular type in over 90% of eyes. Endothelial cell density decreased to about 40% of the eye bank count 2 years after mushroom PK and did not change significantly thereafter. Five years postoperatively, probabilities of graft immunologic rejection and graft survival were below 5% and above 95%, respectively. There was no statistically significant difference in endothelial cell loss, graft rejection, and survival probability between low-risk and high-risk subgroups. Conclusions: Refractive and visual outcomes of mushroom PK compare favorably with those of conventional full-thickness keratoplasty. In eyes at high risk for immunologic rejection, mushroom PK provides a considerably higher probability of graft survival than conventional PK. PMID:26538771

  13. Comparison of split double and triple twists in pair figure skating.

    PubMed

    King, Deborah L; Smith, Sarah L; Brown, Michele R; McCrory, Jean L; Munkasy, Barry A; Scheirman, Gary I

    2008-05-01

    In this study, we compared the kinematic variables of the split triple twist with those of the split double twist to help coaches and scientists understand these landmark pair skating skills. High-speed video was taken during the pair short and free programmes at the 2002 Salt Lake City Winter Olympics and the 2003 International Skating Union Grand Prix Finals. Three-dimensional analyses of 14 split double twists and 15 split triple twists from eleven pairs were completed. In spite of considerable variability in the performance variables among the pairs, the main difference between the split double twists and split triple twists was an increase in rotational rate. While eight of the eleven pairs relied primarily on an increased rotational rate to complete the split triple twist, three pairs employed a combined strategy of increased rotational rate and increased flight time due predominantly to delayed or lower catches. These results were similar to observations of jumps in singles skating for which the extra rotation is typically due to an increase in rotational velocity; increases in flight time come primarily from delayed landings as opposed to additional height during flight. Combining an increase in flight time and rotational rate may be a good strategy for completing the split triple twist in pair skating.

  14. Triple Value Simulation Model Fact Sheet

    EPA Pesticide Factsheets

    The Triple Value Simulation (3VS) is a high-level model that accounts for the complex relationships among economic, social and environmental systems in order to explore scenarios and solutions to improve the health of the Bay.

  15. Triple X Syndrome: Symptoms and Causes

    MedlinePlus

    ... be more pronounced — possibly including developmental delays and learning disabilities. Treatment for triple X syndrome depends on which ... motor skills, such as sitting up and walking Learning disabilities, such as difficulty with reading (dyslexia), understanding or ...

  16. Syntheses, structures and redox properties of some complexes containing the Os(dppe)Cp* fragment, including [{Os(dppe)Cp*}2(mu-C triple bondCC triple bond C)].

    PubMed

    Bruce, Michael I; Costuas, Karine; Davin, Thomas; Halet, Jean-François; Kramarczuk, Kathy A; Low, Paul J; Nicholson, Brian K; Perkins, Gary J; Roberts, Rachel L; Skelton, Brian W; Smith, Mark E; White, Allan H

    2007-12-14

    The sequential conversion of [OsBr(cod)Cp*] (9) to [OsBr(dppe)Cp*] (10), [Os([=C=CH2)(dppe)Cp*]PF6 ([11]PF6), [Os(C triple bond CH)(dppe)Cp*] (12), [{Os(dppe)Cp*}2{mu-(=C=CH-CH=C=)}][PF6]2 ([13](PF6)2) and finally [{Os(dppe)Cp*}(2)(mu-C triple bond CC triple bond C)] (14) has been used to make the third member of the triad [{M(dppe)Cp*}2(mu-C triple bond CC triple bond C)] (M = Fe, Ru, Os). The molecular structures of []PF6, 12 and 14, together with those of the related osmium complexes [Os(NCMe)(dppe)Cp*]PF6 ([15]PF6) and [Os(C triple bond CPh)(dppe)Cp*] (16), have been determined by single-crystal X-ray diffraction studies. Comparison of the redox properties of 14 with those of its iron and ruthenium congeners shows that the first oxidation potential E1 varies as: Fe approximately Os < Ru. Whereas the Fe complex has been shown to undergo three sequential 1-electron oxidation processes within conventional electrochemical solvent windows, the Ru and Os compounds undergo no fewer than four sequential oxidation events giving rise to a five-membered series of redox related complexes [{M(dppe)Cp*}2(mu-C4)]n+ (n = 0, 1, 2, 3 and 4), the osmium derivatives being obtained at considerably lower potentials than the ruthenium analogues. These results are complimented by DFT and DT DFT calculations.

  17. Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Ratcliffe, Alicia C.

    2018-01-01

    The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the

  18. Triple-negative breast cancer: current state of the art.

    PubMed

    Rastelli, Francesca; Biancanelli, Sandra; Falzetta, Amalia; Martignetti, Angelo; Casi, Camilla; Bascioni, Romeo; Giustini, Lucio; Crispino, Sergio

    2010-01-01

    Triple-negative breast cancer, defined by a lack of expression of estrogen, progesterone and HER-2 receptors, accounts for 15% of all types of breast cancer. The subtype mainly includes a molecularly distinct subgroup, the basal-like subtype (accounting for 75% of all cases). We attempt to define triple-negative breast cancer and compare it with basal-like disease, review the molecular, pathologic and clinical features of triple-negative disease, provide an overview of a retrospective subset analysis of clinical trials, and outline ongoing therapeutic trials and possible paths for future research. We collected data regarding classification, molecular and clinical features and treatment, drawn from the existing literature, including abstracts and verbal accounts. By the term "basal-like", we defined all cases where gene expression array or more sophisticated immunophenotypes are used for identification. When the analysis is restricted to clinical assay (immunohistochemistry), we refer to "triple-negative". Basal-like breast cancer expresses genes characteristic of basal epithelial cells, which include high-molecular weight basal cytokeratins (CK5/6, CK14, CK17), vimentin, p-cadherin, alpha B crystalline, caveolins 1 and 2 and EGFR. The expression of basal markers (basal cytokeratins and EGFR) is related to a worse prognosis and identifies a clinically distinct subgroup within the triple-negative breast cancer. BRCA1 mutations are present in 11% of triple-negative tumors and even more rare is BRCA2 deficiency. BR-CA1-associated breast cancers types are typically characterized by a high rate of DNA aberrations and defective DNA repair pathways (the so-called "BRCAness"). The use of regimens based on DNA-damaging agents, such as anthracyclines, platinum derivatives and cyclophosphamide seems a sensible option for this breast cancer subtypes. Clinical data support a strong sensitivity to primary chemotherapy with pathologic response rates ranging from 27-45% (with

  19. Precut cornea for Descemet's stripping endothelial keratoplasty: experience at a single eye bank.

    PubMed

    Mohamed, Ashik; Chaurasia, Sunita; Chandragiri, Venkataswamy; Kandhibanda, Srinivas; Gunnam, Srinivas; Garg, Prashant

    2017-06-01

    The aim of the study is to describe the experience with precut facility for endothelial keratoplasty at a single eye bank affiliated to a tertiary eye care center in India. Data on precut tissues from Nov 2012 to Dec 2014 were retrospectively reviewed from the electronic database of the eye bank of a tertiary eye care center in South India. Donor characteristic data including donor age, precut and postcut endothelial cell density (ECD), recipient age, and thickness of graft were collected. The number of precuts increased from 42 in 2012 (Nov and Dec) and 422 in 2013 to 584 in 2014. Of the total of 1048 precuts, seven (0.67 %) were miscut and could not be utilized for transplants. The donor age ranged from 2 to 89 years. A mean change of 43.6 ± 325.2 cells/mm 2 in ECD was noted after cut, proportional increase in mean being 1.9 %. The change in ECD after cut was negatively correlated with ECD before cut. The recipient age ranged from 1 to 89 years. The median thickness of donor lenticule after cut was 148 µm (interquartile range 131-166 µm). Analysis of precut donor corneas from a single eye bank shows that the ECD of the processed tissues was excellent for transplantation. The tissue wastage in the hands of eye bank personal was minimal.

  20. Targeting Tryptophan Catabolism: A Novel Method to Block Triple-Negative Breast Cancer Metastasis

    DTIC Science & Technology

    2017-04-01

    AWARD NUMBER: W81XWH-15-1-0039 TITLE: Targeting Tryptophan Catabolism: A Novel Method to Block Triple- Negative Breast Cancer Metastasis...Mar 2017 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Targeting Tryptophan Catabolism: A Novel Method to Block Triple-Negative Breast Cancer...Tryptophan Catabolism: A Novel Method to Block Triple-Negative Breast Cancer Metastasis,” Submitted by Jennifer K. Richer, PhD, University of Colorado

  1. Natural triple beta-stranded fibrous folds.

    PubMed

    Mitraki, Anna; Papanikolopoulou, Katerina; Van Raaij, Mark J

    2006-01-01

    A distinctive family of beta-structured folds has recently been described for fibrous proteins from viruses. Virus fibers are usually involved in specific host-cell recognition. They are asymmetric homotrimeric proteins consisting of an N-terminal virus-binding tail, a central shaft or stalk domain, and a C-terminal globular receptor-binding domain. Often they are entirely or nearly entirely composed of beta-structure. Apart from their biological relevance and possible gene therapy applications, their shape, stability, and rigidity suggest they may be useful as blueprints for biomechanical design. Folding and unfolding studies suggest their globular C-terminal domain may fold first, followed by a "zipping-up" of the shaft domains. The C-terminal domains appear to be important for registration because peptides corresponding to shaft domains alone aggregate into nonnative fibers and/or amyloid structures. C-terminal domains can be exchanged between different fibers and the resulting chimeric proteins are useful as a way to solve structures of unknown parts of the shaft domains. The following natural triple beta-stranded fibrous folds have been discovered by X-ray crystallography: the triple beta-spiral, triple beta-helix, and T4 short tail fiber fold. All have a central longitudinal hydrophobic core and extensive intermonomer polar and nonpolar interactions. Now that a reasonable body of structural and folding knowledge has been assembled about these fibrous proteins, the next challenge and opportunity is to start using this information in medical and industrial applications such as gene therapy and nanotechnology.

  2. Constraints from triple gauge couplings on vectorlike leptons

    DOE PAGES

    Bertuzzo, Enrico; Machado, Pedro A. N.; Perez-Gonzalez, Yuber F.; ...

    2017-08-30

    Here, we study the contributions of colorless vectorlike fermions to the triple gauge couplings W +W -γ and W +W -Z 0. We consider models in which their coupling to the Standard Model Higgs boson is allowed or forbidden by quantum numbers. We assess the sensitivity of the future accelerators FCC-ee, ILC, and CLIC to the parameters of these models, assuming they will be able to constrain the anomalous triple gauge couplings with precision δ κV~O(10 -4), V = γ,Z 0. We show that the combination of measurements at different center-of-mass energies helps to improve the sensitivity to the contributionmore » of vectorlike fermions, in particular when they couple to the Higgs. In fact, the measurements at the FCC-ee and, especially, the ILC and the CLIC, may turn the triple gauge couplings into a new set of precision parameters able to constrain the models better than the oblique parameters or the H → γγ decay, even assuming the considerable improvement of the latter measurements achievable at the new machines.« less

  3. Constraints from triple gauge couplings on vectorlike leptons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bertuzzo, Enrico; Machado, Pedro A. N.; Perez-Gonzalez, Yuber F.

    Here, we study the contributions of colorless vectorlike fermions to the triple gauge couplings W +W -γ and W +W -Z 0. We consider models in which their coupling to the Standard Model Higgs boson is allowed or forbidden by quantum numbers. We assess the sensitivity of the future accelerators FCC-ee, ILC, and CLIC to the parameters of these models, assuming they will be able to constrain the anomalous triple gauge couplings with precision δ κV~O(10 -4), V = γ,Z 0. We show that the combination of measurements at different center-of-mass energies helps to improve the sensitivity to the contributionmore » of vectorlike fermions, in particular when they couple to the Higgs. In fact, the measurements at the FCC-ee and, especially, the ILC and the CLIC, may turn the triple gauge couplings into a new set of precision parameters able to constrain the models better than the oblique parameters or the H → γγ decay, even assuming the considerable improvement of the latter measurements achievable at the new machines.« less

  4. Triple Achilles Tendon Rupture: Case Report.

    PubMed

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Isotopically enhanced triple-quantum-dot qubit

    PubMed Central

    Eng, Kevin; Ladd, Thaddeus D.; Smith, Aaron; Borselli, Matthew G.; Kiselev, Andrey A.; Fong, Bryan H.; Holabird, Kevin S.; Hazard, Thomas M.; Huang, Biqin; Deelman, Peter W.; Milosavljevic, Ivan; Schmitz, Adele E.; Ross, Richard S.; Gyure, Mark F.; Hunter, Andrew T.

    2015-01-01

    Like modern microprocessors today, future processors of quantum information may be implemented using all-electrical control of silicon-based devices. A semiconductor spin qubit may be controlled without the use of magnetic fields by using three electrons in three tunnel-coupled quantum dots. Triple dots have previously been implemented in GaAs, but this material suffers from intrinsic nuclear magnetic noise. Reduction of this noise is possible by fabricating devices using isotopically purified silicon. We demonstrate universal coherent control of a triple-quantum-dot qubit implemented in an isotopically enhanced Si/SiGe heterostructure. Composite pulses are used to implement spin-echo type sequences, and differential charge sensing enables single-shot state readout. These experiments demonstrate sufficient control with sufficiently low noise to enable the long pulse sequences required for exchange-only two-qubit logic and randomized benchmarking. PMID:26601186

  6. Outcomes of endothelial keratoplasty in pseudophakic corneal oedema: with or without Descemet's membrane stripping.

    PubMed

    Mohamed, Ashik; Ks, Anil Raj; Chaurasia, Sunita; Ramappa, Muralidhar

    2016-06-01

    To evaluate and compare outcomes of Descemet's stripping endothelial keratoplasty (DSEK) with non-DSEK (nDSEK) in pseudophakic corneal oedema (PCE). The study was a prospective, non-consecutive, comparative, interventional case series. Twenty-six patients with PCE were randomised into two groups. Group 1 comprised of those cases that had undergone conventional DSEK, and group 2 consisted of those that had nDSEK for PCE between 2010 and 2012. The data on demographics and clinical characteristics were collected from all patients. Any intraoperative and early and late postoperative complications were also noted. The primary outcome measure was postoperative functional success. Graft survival and complications were analysed as secondary outcomes. The median best-corrected visual acuities at 6 months postoperatively in groups 1 and 2 were 0.18 (IQR 0.10-0.30) and 0.44 (IQR 0.18-0.51), respectively (p=0.11). Corneal oedema cleared in all patients. During the early postoperative period, a patient in group 2 had lenticule detachment managed by rebubbling. nDSEK has outcomes similar to DSEK in PCE with advantages of decreased surgical time and avoidance of inadvertent pull on the posterior stromal fibres that may occur during Descemet's stripping. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Triple Junctions, Boninites, and a New Microplate in the Western Pacific

    NASA Astrophysics Data System (ADS)

    Flores, J. A.; Casey, J.

    2017-12-01

    A new microplate has been discovered while trying to correlate melting processes in subduction zones that are forming boninites along the southern Mariana Plate. The westward boundary between the Mariana plate and the Philippine Sea plate is along a well-defined back-arc spreading center. The southern extension of this spreading center to the intersection with the Mariana Trench does not have a recognized morphological boundary. Previous work has hypothesized that subduction beneath a spreading center provides conditions required for boninite petrogenesis. Therefore, the exact location of the trench-trench-ridge triple junction needs to be found and correlated with known boninite locations. The triple junction was found using fault plane solutions to constrain the southern boundary of the two plates as it transects across the forearc. Normal faults suggest the triple junction to be at approximately 11.9N 144.1W; slip direction of reverse faults associated with the subducting plate are dominantly north-south west of this junction and northwest-southeast on the east side. While locating the southern boundary, the nucleation of a new spreading center that creates a ridge-ridge-ridge triple junction was found. The main spreading center trends mostly north-south until about 12.5N 143W, where two other spreading centers meet. The western spreading zone trends mostly east-west and seems to be in its infancy whereas there is another spreading center trending northwest-southeast. It is this last spreading center that forms the trench-ridge-trench triple junction. Discovery of these triple junctions isolates a piece of lithosphere that we interpret to be a new microplate that we name the Challenger Microplate.

  8. Perilimbal bevacizumab injection for interface neovascularization after deep anterior lamellar keratoplasty.

    PubMed

    Foroutan, Alireza; Fariba, Beigzadeh; Pejman, Bakhtiari; Mahmoud, Joshaghani; Khalil, Ghasemi Falavarjani; Arash, Ehteshami Afshar; Foroutan, Pooria

    2010-11-01

    To evaluate the effect of perilimbal bevacizumab injection on neovascularization at the interface of donor and recipient tissues after deep anterior lamellar keratoplasty (DALK). This interventional case series included 4 patients with interface neovascularization after DALK (3 patients with advanced keratoconus and 1 patient with scarring because of herpetic keratitis). Bevacizumab (2.5 mg/0.1 mL) was injected subconjunctivally near the limbus adjacent to the abnormal blood vessels. Depending on regression of new vessels, injections were repeated. If neovascularization occurred in more than 1 quadrant, injections were administered at 2 sites (2.5 mg for each injection). Total corneal neovascularization, longest neovascular length, and degree of neovascular circumference were evaluated by digital slit lamp corneal photography before injection and 1 week, 1, 3, and 6 months afterward. The mean follow-up period was 14 ± 7.52 months from the first bevacizumab injection. Corneal neovascularization, on average,was 33.70% ± 7.8% (SD) of the total corneal surface before the injections, which decreased to 4.83% ± 3.3% (P = 0.005, t test) at the last follow-up examination. Mean degree of neovascularized circumference decreased from 165 degrees before injection to 77.5 degrees (P = 0.023) at the last follow-up examination. Mean longest neovascularized length decreased from 6.714 mm before injection to 1.497 mm (P = 0.021) at the last follow-up examination. At the end of the study, all patients had clear grafts with no sign of graft failure. Mean best-corrected visual acuity before injection was 20/100, which improved to 20/30 at the last examination. This small case series suggests that perilimbal bevacizumab injection is safe and effective for partial regression of new blood vessels at the interface of donor and recipient tissues after DALK and may effectively prevent graft rejection.

  9. Triple-activated blast furnace slag

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clarke, W.J.

    1995-12-31

    The current shortage of portland cement in the world will require the use of Ground Granulated Blast Furnace Slag (GGBFS) to fill demands in many industrialized countries. Therefore, an extensive series of triple-activated slag experiments have been undertaken to optimize an economical combination of mechanical properties for alkali-activated slags. Na{sub 2}OSiO{sub 2} (N Grade), Ca(OH){sub 2}, H{sub 2}O and Na{sub 2}CO{sub 3} have been added as activators in 5 to 10, 0 to 5 and 0 to 5 weight percentages of water and slag in a mix with a water:cement ratio of 1:1. Silica Fume and Sika 10 superplasticizer havemore » been added as 1 and 10 weight percent of slag. Set times, initial hardening times and compressive strengths at percentages of the mix to identify more refined formulations. Finally, the resulting aggregate to develop a triple-activated slag formulation with the ultimate objective of contributing toward satisfying the world shortage of high performance concrete.« less

  10. The chemical end-ligation of homopyrimidine oligodeoxyribonucleotides within a DNA triple helix.

    PubMed

    Li, T; Weinstein, D S; Nicolaou, K

    1997-03-01

    Triple-helical nucleic acids, first reported in the late 1950s, are receiving attention for their possible involvement in controlling gene expression. Certain sequences of DNA are believed to form local triple-helical structures (H-form DNA), although this has not been directly observed in vivo. Studies carried out in our laboratories have suggested that self-replicating oligonucleotides could have been involved in chemical evolution via triple-helical intermediates. In addition to self-replication mechanisms, elucidating processes for the nonenzymatic elongation of biologically relevant polymers remains an important challenge in understanding the origin of life. To this end, we have studied a novel ligation of oligodeoxyribonucleotides that lie within a triple helix. The chemical end-ligation of homopyrimidine oligodeoxyribonucleotides on a triple helix is reported. This selective process, induced by cyanoimidazole, is facilitated by a template effect of the DNA aggregate and occurs between the 3' end (hydroxyl) of the third minor-groove-bound strand and the 5' end (phosphate) of the antiparallel oligopyrimidine strand. Double-helical homopurine/homopyrimidine DNA can serve as a template for the elongation of oligonucleotides in a manner that has not been described previously. The end-ligation of homopyrimidine oligomers, a nonenzymatic process, proceeds via a requisite triple-helical intermediate and constitutes an efficient and selective method for the template-directed elongation of nucleic acids. Such a process could conceivably have been involved in the elongation of primordial information-bearing biopolymers.

  11. An overview of triple infection with hepatitis B, C and D viruses.

    PubMed

    Riaz, Mehwish; Idrees, Muhamad; Kanwal, Hifza; Kabir, Firoz

    2011-07-27

    Viral hepatitis is one of the major health problems worldwide, particularly in South East Asian countries including Pakistan where hepatitis C virus (HCV) and hepatitis B virus (HBV) infections are highly endemic. Hepatitis delta virus (HDV) is also not uncommon world-wide. HCV, HBV, and HDV share parallel routes of transmission due to which dual or triple viral infection can occur in a proportion of patients at the same time. HBV and HCV are important factors in the development of liver cirrhosis (LC) and hepatocellular carcinoma (HCC). In addition to LC and HCC, chronic HDV infection also plays an important role in liver damage with oncogenic potential.The current article reviews the available literature about the epidemiology, pathogenesis, transmission, symptoms, diagnosis, replication, disease outcome, treatment and preventive measures of triple hepatitis infection by using key words; epidemiology of triple infection, risk factors, awareness status, treatment and replication cycle in PubMed, PakMediNet, Directory of Open Access Journals (DOAJ) and Google Scholar. Total data from 74 different studies published from 1983 to 2010 on triple hepatitis infections were reviewed and included in this study. The present article briefly describes triple infection with HCV, HBV and HDV.

  12. Direct imaging discovery of a Jovian exoplanet within a triple-star system.

    PubMed

    Wagner, Kevin; Apai, Dániel; Kasper, Markus; Kratter, Kaitlin; McClure, Melissa; Robberto, Massimo; Beuzit, Jean-Luc

    2016-08-12

    Direct imaging allows for the detection and characterization of exoplanets via their thermal emission. We report the discovery via imaging of a young Jovian planet in a triple-star system and characterize its atmospheric properties through near-infrared spectroscopy. The semimajor axis of the planet is closer relative to that of its hierarchical triple-star system than for any known exoplanet within a stellar binary or triple, making HD 131399 dynamically unlike any other known system. The location of HD 131399Ab on a wide orbit in a triple system demonstrates that massive planets may be found on long and possibly unstable orbits in multistar systems. HD 131399Ab is one of the lowest mass (4 ± 1 Jupiter masses) and coldest (850 ± 50 kelvin) exoplanets to have been directly imaged. Copyright © 2016, American Association for the Advancement of Science.

  13. Triple-effect absorption refrigeration system with double-condenser coupling

    DOEpatents

    DeVault, R.C.; Biermann, W.J.

    1993-04-27

    A triple effect absorption refrigeration system is provided with a double-condenser coupling and a parallel or series circuit for feeding the refrigerant-containing absorbent solution through the high, medium, and low temperature generators utilized in the triple-effect system. The high temperature condenser receiving vaporous refrigerant from the high temperature generator is double coupled to both the medium temperature generator and the low temperature generator to enhance the internal recovery of heat within the system and thereby increase the thermal efficiency thereof.

  14. Triple-effect absorption refrigeration system with double-condenser coupling

    DOEpatents

    DeVault, Robert C.; Biermann, Wendell J.

    1993-01-01

    A triple effect absorption refrigeration system is provided with a double-condenser coupling and a parallel or series circuit for feeding the refrigerant-containing absorbent solution through the high, medium, and low temperature generators utilized in the triple-effect system. The high temperature condenser receiving vaporous refrigerant from the high temperature generator is double coupled to both the medium temperature generator and the low temperature generator to enhance the internal recovery of heat within the system and thereby increase the thermal efficiency thereof.

  15. The use of endoillumination probe-assisted Descemet membrane endothelial keratoplasty for bullous keratopathy secondary to argon laser iridotomy

    PubMed Central

    Kobayashi, Akira; Yokogawa, Hideaki; Yamazaki, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa

    2015-01-01

    Purpose To report the first case of Descemet membrane endothelial keratoplasty (DMEK) for bullous keratopathy (BK) secondary to argon laser iridotomy (ALI). Patient A 71-year-old woman presented with decreased visual acuity in her right eye due to BK secondary to ALI that was performed 10 years prior. Results Phacosurgery was performed first, followed by successful DMEK 4 months later. A DMEK shooter was used for donor insertion, which allowed for a stable anterior chamber during donor insertion, even when the anterior chamber was quite shallow. Also, removal of edematous epithelial cells and endoillumination probe-assisted DMEK was quite useful to visualize DMEK graft on the background of the dark brown iris seen in Asian eyes. The patient’s best corrected visual acuity rapidly increased from 20/200 to 25/20 after 1 month, with complete resolution of corneal edema. Conclusion We reported the first successful DMEK case for BK secondary to ALI. The use of a DMEK shooter for donor insertion and endoillumination assistance to visualize the DMEK graft was a useful technique for BK secondary to ALI. PMID:25609910

  16. Upfront triple combination therapy in pulmonary arterial hypertension: a pilot study.

    PubMed

    Sitbon, Olivier; Jaïs, Xavier; Savale, Laurent; Cottin, Vincent; Bergot, Emmanuel; Macari, Elise Artaud; Bouvaist, Hélène; Dauphin, Claire; Picard, François; Bulifon, Sophie; Montani, David; Humbert, Marc; Simonneau, Gérald

    2014-06-01

    Patients with severe pulmonary arterial hypertension (PAH) in New York Heart Association (NYHA) functional class (FC) III/IV have a poor prognosis, despite survival benefits being demonstrated with intravenous epoprostenol. In this pilot study, the efficacy and safety of a triple combination therapy regimen in patients with severe PAH was investigated. Data from newly diagnosed NYHA FC III/IV PAH patients (n=19) initiated on upfront triple combination therapy (intravenous epoprostenol, bosentan and sildenafil) were collected retrospectively from a prospective registry. Significant improvements in 6-min walk distance and haemodynamics were observed after 4 months' triple combination therapy in 18 patients (p<0.01); 17 patients had improved to NYHA FC I or II. One patient was not included in the month 4 assessment (due to an emergency lung transplant in month 3). At the final evaluation (mean ± sd 32 ± 19 months), all 18 patients had sustained clinical and haemodynamic improvement. Overall survival estimates for the triple combination cohort were 100% at 1, 2 and 3 years. Expected survival calculated from the French equation was 75% (95% CI 68-82%), 60% (95% CI 50-70%) and 49% (95% CI 38-60%) at 1, 2 and 3 years, respectively. This pilot study provides preliminary evidence of the long-term benefits of upfront triple combination therapy in patients with severe PAH. ©ERS 2014.

  17. Binaries and triples among asteroid pairs

    NASA Astrophysics Data System (ADS)

    Pravec, Petr; Scheirich, Peter; Kušnirák, Peter; Hornoch, Kamil; Galád, Adrián

    2015-08-01

    Despite major achievements obtained during the past two decades, our knowledge of the population and properties of small binary and multiple asteroid systems is still far from advanced. There is a numerous indirect evidence for that most small asteroid systems were formed by rotational fission of cohesionless parent asteroids that were spun up to the critical frequency presumably by YORP, but details of the process are lacking. Furthermore, as we proceed with observations of more and more binary and paired asteroids, we reveal new facts that substantially refine and sometimes change our understanding of the asteroid systems. One significant new finding we have recently obtained is that primaries of many asteroid pairs are actually binary or triple systems. The first such case found is (3749) Balam (Vokrouhlický, ApJL 706, L37, 2009). We have found 9 more binary systems among asteroid pairs within our ongoing NEOSource photometric project since October 2012. They are (6369) 1983 UC, (8306) Shoko, (9783) Tensho-kan, (10123) Fideoja, (21436) Chaoyichi, (43008) 1999 UD31, (44620) 1999 RS43, (46829) 1998 OS14 and (80218) 1999 VO123. We will review their characteristics. These paired binaries as we call them are mostly similar to binaries in the general ("background") population (of unpaired asteroids), but there are a few trends. The paired binaries tend to have larger secondaries with D_2/D_1 = 0.3 to 0.5 and they also tend to be wider systems with 8 of the 10 having orbital periods between 30 and 81 hours, than average among binaries in the general population. There may be also a larger fraction of triples; (3749) Balam is a confirmed triple, having a larger close and a smaller distant satellite, and (8306) Shoko and (10123) Fideoja are suspect triples as they show additional rotational lightcurve components with periods of 61 and 38.8 h that differ from the orbital period of 36.2 and 56.5 h, respectively. The unbound secondaries tend to be of the same size or

  18. Penetrating keratoplasty for keratoconus: role of videokeratoscopy and trephine sizing.

    PubMed

    Serdarevic, O N; Renard, G J; Pouliquen, Y

    1996-11-01

    To evaluate whether determining graft-host trephine disparity on the basis of videokeratoscopic data of keratoconus patients having penetrating keratoplasty (PKP) reduces ametropia and to correlate preoperative videokeratoscopic values, posterior axial length (PAL), and trephine disparity with postoperative refractive outcomes. Hôtel-Dieu, University of Paris, France. This randomized clinical trial comprised 18 keratoconus patients who had PKP. After computerized videokeratoscopic analysis, patients were randomly assigned to a test or control group with matching for midperipheral corneal keratoscopic criteria. One surgeon performed all grafts using the same technique (except for donor button punching with an 8.00 or 8.25 mm blade, depending on preoperative keratoscopy) with suction trephination (8.00) and a running 10-0 nylon suture. The PAL (total axial length minus the distance from the anterior corneal surface to the anterior lens surface) was measured by applanation ultrasonography. Refraction and videokeratoscopic analysis were done 18 months postoperatively (6 months after suture removal). The mean deviation from emmetropia corrected for PAL in test group patients who had trephine sizing based on the hypothesis that preoperative videokeratoscopy is a useful determining factor was 1.12 diopters (D) +/- 0.74 (SD), which was significantly smaller (P = .005) than that in the control group (2.19 +/- 0.85 D). The test group had uncorrected visual acuities of 20/50 or better. Postoperative spherical equivalent was affected by PAL (P = .0001), preoperative keratoscopy (P = .0001), and trephine disparity (P = .01). Central corneal power after grafting was influenced by keratoscopy (P = .0001) and trephine disparity (P = .002). Uncorrected visual acuity was affected by PAL (P = .001) and keratoscopic data (P = .01). Parameters for reducing ametropia after grafting of keratoconus patients can be developed for each surgeon based on trephine disparity dependent on

  19. Assessment of the Accuracy and Cut-Failure Rates of Eye Bank-Cut Corneas for Use in Endothelial Keratoplasty: A Comparison of Outcomes Between 2010 and 2013.

    PubMed

    Katzman, Lee R; Hoover, Caroline K; Khalifa, Yousuf M; Jeng, Bennie H

    2015-11-01

    To evaluate the accuracy of eye bank-prepared precut donor corneas over time by comparing cut-failure rates and corneal thickness measurements in 2010 and 2013. A total of 2511 human corneas cut by a technician-operated mechanical microkeratome intended for endothelial keratoplasty were evaluated prospectively at one large eye bank facility in 2010 and in 2013. The endothelium was evaluated by slit lamp, and specular microscopy both before and after cutting was performed. Graft thickness as measured by pachymetry and/or optical coherence tomography was collected to assess the accuracy of the cut tissue. Cut-failure rates were compared between normal donor tissue and tissue with significant preexisting scarring. The combined cut-failure rate in 2010 and 2013 was 2.3% (23/1000) and 1.6% (24/1511), respectively (P = 0.23). The cut-failure rate among normal tissue in 2010 and 2013 was 2.0% (19/927) and 1.4% (19/1400), respectively (P = 0.24). The cut-failure rate among previously scarred tissue in 2010 and 2013 was 5.5% (4/73) and 4.5% (5/111), respectively (P = 0.74). The mean surgeon-requested graft thickness was 144.7 μm (range 100-150, SD 13.6) and 127.2 μm (range 75-150, SD 25.2) in 2010 and 2013, respectively (P < 0.0001). The mean deviation from target graft thickness was 21.3 μm (SD 16.3) and 13.6 μm (SD 12.5) in 2010 and 2013, respectively (P < 0.0001). From 2010 to 2013, the combined cut-failure rates trended toward improvement, while the accuracy of graft thickness improved. This study suggests that the accuracy and success rates of tissue preparation for endothelial keratoplasty improve with experience and volume.

  20. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    NASA Astrophysics Data System (ADS)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or

  1. An empirical understanding of triple collocation evaluation measure

    NASA Astrophysics Data System (ADS)

    Scipal, Klaus; Doubkova, Marcela; Hegyova, Alena; Dorigo, Wouter; Wagner, Wolfgang

    2013-04-01

    Triple collocation method is an advanced evaluation method that has been used in the soil moisture field for only about half a decade. The method requires three datasets with an independent error structure that represent an identical phenomenon. The main advantages of the method are that it a) doesn't require a reference dataset that has to be considered to represent the truth, b) limits the effect of random and systematic errors of other two datasets, and c) simultaneously assesses the error of three datasets. The objective of this presentation is to assess the triple collocation error (Tc) of the ASAR Global Mode Surface Soil Moisture (GM SSM 1) km dataset and highlight problems of the method related to its ability to cancel the effect of error of ancillary datasets. In particular, the goal is to a) investigate trends in Tc related to the change in spatial resolution from 5 to 25 km, b) to investigate trends in Tc related to the choice of a hydrological model, and c) to study the relationship between Tc and other absolute evaluation methods (namely RMSE and Error Propagation EP). The triple collocation method is implemented using ASAR GM, AMSR-E, and a model (either AWRA-L, GLDAS-NOAH, or ERA-Interim). First, the significance of the relationship between the three soil moisture datasets was tested that is a prerequisite for the triple collocation method. Second, the trends in Tc related to the choice of the third reference dataset and scale were assessed. For this purpose the triple collocation is repeated replacing AWRA-L with two different globally available model reanalysis dataset operating at different spatial resolution (ERA-Interim and GLDAS-NOAH). Finally, the retrieved results were compared to the results of the RMSE and EP evaluation measures. Our results demonstrate that the Tc method does not eliminate the random and time-variant systematic errors of the second and the third dataset used in the Tc. The possible reasons include the fact a) that the TC

  2. Decreased triple network connectivity in patients with post-traumatic stress disorder

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Li, Liang; Li, Baojuan; Zhang, Xi; Lu, Hongbing

    2017-03-01

    The triple network model provides a common framework for understanding affective and neurocognitive dysfunctions across multiple disorders, including central executive network (CEN), default mode network (DMN), and salience network (SN). Considering the effect of traumatic experience on post-traumatic stress disorder (PTSD), this study aims to explore the alteration of triple network connectivity in a specific PTSD induced by a single prolonged trauma exposure. With arterial spin labeling sequence, three networks were identified using independent component analysis in 10 PTSD patients and 10 healthy survivors, who experienced the same coal mining flood disaster. In PTSD patients, decreased connectivity was identified in left middle frontal gyrus of CEN, left precuneus and bilateral superior frontal gyrus of DMN, and right anterior insula of SN. The decreased connectivity in left middle frontal gyrus was identified to associate with clinical severity. These results indicated the decreased triple network connectivity, which not only supported the proposal of the triple network model, but also prompted possible neurobiology mechanism of cognitive dysfunction for this kind of PTSD.

  3. Stability of planetary orbits in triple star systems

    NASA Astrophysics Data System (ADS)

    Busetti, Franco; Beust, Hervé; Harley, Charis

    2018-06-01

    Triple stellar systems comprising a central binary orbited by a third star at a larger distance are fairly common. However, there have been very few studies on the stability of planetary orbits in such systems. There has been almost no work on generalised systems, little on retrograde planetary orbits and none on retrograde stellar orbits, with nearly all being for coplanar orbits and for a limited number of orbital parameters. We provide a generalised numerical mapping of the regions of planetary stability in triples, using the symplectic N-body code HJS (Beust 2003) designed for the dynamics of multiple hierarchical systems. We investigate all these orbit types and extend the parameters used to all relevant orbital elements of the triple’s stars, also expanding these elements and mass ratios to wider ranges.This establishes the regions of secular stability and results in empirical models describing the stability bounds for planets in each type of triple configuration, as functions of the various system parameters. These results are compared to the corresponding results for binaries in the limit of a vanishing mass of the third star. A general feature is that retrograde planetary orbits appear more stable than prograde ones, and that stable regions also tend to be wider when the third star's motion is retrograde. Conversely, we point out the destabilizing role of Kozai-Lidov resonance in non-coplanar systems, which shrinks the stability regions as a result of large induced eccentricity variations. Nonetheless, large enough stability regions for planets do exist in triples, and this should motivate future observational campaigns.Refs : Beust, 2003, A&A 400, 1129 Busetti, Beust, Harley, 2018, to be submitted to A&A

  4. 10.4% Efficient triple organic solar cells containing near infrared absorbers

    NASA Astrophysics Data System (ADS)

    Meerheim, Rico; Körner, Christian; Oesen, Benjamin; Leo, Karl

    2016-03-01

    The efficiency of organic solar cells can be increased by serially stacked subcells with spectrally different absorber materials. For the triple junction devices presented here, we use the small molecule donor materials DCV5T-Me for the green region and Tol2-benz-bodipy or Ph2-benz-bodipy as near infrared absorbers. The broader spectral response allows an efficiency increase from a pure DCV5T-Me triple cell to a triple junction containing a Ph2-benz-bodipy subcell, reaching 10.4%. As often observed for organic photovoltaics, the efficiency is further increased at low light intensities to 11%, which allows improved energy harvesting under real outdoor conditions and better performance indoor.

  5. Dual Laser-Assisted Lamellar Anterior Keratoplasty with Tophat Graft: A Laboratory Study

    PubMed Central

    Cleary, Catherine; Song, Jonathan C.; Tang, Maolong; Li, Yan; Liu, Ying; Yiu, Samuel; Huang, David

    2011-01-01

    Objectives To develop a dual laser-assisted lamellar anterior keratoplasty (LALAK) technique, using excimer and femtosecond lasers to perform surgery on eye-bank eyes. Methods First we compared corneal stromal surfaces produced by (1) deep excimer ablation, (2) femtosecond lamellar cuts, and (3) manual dissection, and evaluated the effect of excimer laser smoothing with fluid masking on each surface. Masked observers graded scanning electron microscopy (SEM) images on a 5-point roughness scale. Then we performed a 6-mm diameter excimer laser phototherapeutic keratectomy (PTK) ablation to a residual bed thickness of 200μm, followed by laser smoothing. We used the femtosecond laser to cut donors in a modified top-hat design with a thin tapered brim, which fitted into a manually dissected circumferential pocket at the base of the recipient bed. Fourier-domain optical coherence tomography (OCT) was used to measure corneal pachymetry and evaluate graft fit. Results Deep excimer ablation with smoothing (n=4) produced a significantly (p<0.05) smoother surface (grade=3.5) than deep excimer alone (n=4, grade=3.8) or manual dissection with (n=1, grade=3.8) and without smoothing (n=1, grade=4.8). Deep femtosecond cuts (n=2) produced macroscopic concentric ridges on the stromal surface. Experimental LALAK was performed on 4 recipients prepared by deep excimer ablation and 4 donors cut with the femtosecond laser. After suturing good peripheral graft-host match was observed on FD-OCT imaging. Conclusion These preliminary studies show that the LALAK technique permits improved interface smoothness and graft edge matching. Clinical trials are needed to determine whether these improvements can translate to better vision. PMID:22378114

  6. A Policy Framework for Health Systems to Promote Triple Aim Innovation.

    PubMed

    Verma, Amol; Bhatia, Sacha

    2016-01-01

    With the expiry of the Health Accords, provincial governments must face the challenge of improving performance in the context of ageing demographics, increasing multi-morbidity, and real concerns about financial stability. The Institute for Healthcare Improvement Triple Aim articulates fundamental goals that can guide health system transformation: improved population health, enhanced patient experience and reduced or stable per capita costs. Advancing fragmented and costly health systems in pursuit of these goals requires transformative, as opposed to iterative, change. Provincial governments are ideally suited to lead this change by acting as "integrators" who link healthcare organizations and align incentives across the spectrum of delivery. Although there is very limited evidence regarding the effectiveness of system-level reforms, we draw on initiatives from around the world to suggest policies that can promote system-level Triple Aim innovation. We categorize these policies within the classic functions ascribed to health systems: financing, stewardship and resource generation. As healthcare financers, governments should orient procurement policy towards the Triple Aim innovation and reform payment to reward value not volume. As health system stewards, governments should define a Triple Aim vision; measure and report outcomes, patient experience, and costs; integrate across sectors; and facilitate learning from failure and spread of successful innovation. As resource generators, governments should invest in health information technology to exploit "big data" and ensure that professional education equips front-line clinicians with skills necessary to improve systems. There are a number of barriers to system-level Triple Aim innovation. There is a lack of evidence for macro-level policy changes, innovation is costly and complicated, and system reform may not be politically appealing. Triple Aim innovation may also be conflated with organization-level quality

  7. Evaluate Risk/Benefit of Nab Paclitaxel in Combination With Gemcitabine and Carboplatin Compared to Gemcitabine and Carboplatin in Triple Negative Metastatic Breast Cancer (or Metastatic Triple Negative Breast Cancer)

    ClinicalTrials.gov

    2018-03-07

    Breast Tumor; Breast Cancer; Cancer of the Breast; Estrogen Receptor- Negative Breast Cancer; HER2- Negative Breast Cancer; Progesterone Receptor- Negative Breast Cancer; Recurrent Breast Cancer; Stage IV Breast Cancer; Triple-negative Breast Cancer; Triple-negative Metastatic Breast Cancer; Metastatic Breast Cancer

  8. Dark energy in the three-body problem: Wide triple galaxies

    NASA Astrophysics Data System (ADS)

    Emel'yanov, N. V.; Kovalev, M. Yu.; Chernin, A. D.

    2016-04-01

    The structure and evolution of triple galaxy systems in the presence of the cosmic dark-energy background is studied in the framework of the three-body problem. The dynamics of wide triple systems are determinedmainly by the competition between the mutual gravitational forces between the three bodies and the anti-gravity created by the dark-energy background. This problem can be solved via numerical integration of the equations of motion with initial conditions that admit various types of evolutionary behavior of the system. Such dynamical models show that the anti-gravity created by dark energy makes a triple system less tightly bound, thereby facilitating its decay, with a subsequent transition to motion of the bodies away from each other in an accelerating regime with a linear Hubble-law dependence of the velocity on distance. The coefficient of proportionality between the velocity and distance in this asymptotic relation corresponds to the universal value H Λ = 61 km s-1 Mpc-1, which depends only on the dark-energy density. The similarity of this relation to the large-scale recession of galaxies indicates that double and triple galaxies represent elementary dynamical cells realizing the overall behavior of a system dominated by dark energy on their own scale, independent of their masses and dimensions.

  9. Triple-parton scatterings in proton-nucleus collisions at high energies

    NASA Astrophysics Data System (ADS)

    d'Enterria, David; Snigirev, Alexander M.

    2018-05-01

    A generic expression to compute triple-parton scattering (TPS) cross sections in high-energy proton-nucleus (pA) collisions is derived as a function of the corresponding single-parton cross sections and an effective parameter encoding the transverse parton profile of the proton. The TPS cross sections are enhanced by a factor of about 9 A˜eq 2000 in pPb as compared to those in proton-nucleon collisions at the same center-of-mass energy. Estimates for triple charm (c\\overline{c}) and bottom (b\\overline{b}) production in pPb collisions at LHC and FCC energies are presented based on next-to-next-to-leading-order calculations for c\\overline{c} and b\\overline{b} single-parton cross sections. At √{s_{_{sc {nn}}}}= 8.8 TeV, about 10% of the pPb events have three c\\overline{c} pairs produced in separate partonic interactions. At √{s_{_{sc {nn}}}}= 63 TeV, the pPb cross sections for triple-J/ψ and triple-b\\overline{b} are O(1-10 mb). In the most energetic collisions of cosmic rays in the upper atmosphere, equivalent to √{s_{_{sc {nn}}}}≈ 400 TeV, the TPS c\\overline{c} cross section equals the total p-Air inelastic cross section.

  10. The Evolution of the Indian Ocean Triple Junction and the Finite Rotation Problem.

    DTIC Science & Technology

    1980-09-01

    AD-AG&9 103 ~S HOLE OCEANOGRAPHIC INSTITUTION MASS F/6 6/7 THE EVOLUTION OF THE INDIAN OCEAN TRIPLE JUNCTION AND THE FINIT-ETC(U1 SEP 80 C R TAPSCOTT...1111flfl 1.4 111116 MICROCOPY RESOLUTION TEST CHART WHOI-80-37 THE EVOLUTION OF THE INDIAN OCEAN TRIPLE JUNCTION AND THE FINITE ROTATION PROBLEM by...purpose of the United States Government. This thesis should be cited as: Christopher R. Tapscott, 1979. The Evolution of the Indian Ocean Triple Junction

  11. Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    PubMed

    van Hoof, Stefan J; Granton, Patrick V; Landry, Guillaume; Podesta, Mark; Verhaegen, Frank

    2012-07-07

    A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (pre-IR) film scan, using EBT2 film and kilo- and megavoltage photon beams up to 10 Gy. When considering regions of interest averaged doses, the triple-channel method and both single-channel methods produced equivalent results. Absolute dose discrepancies between the triple-channel method, both single-channel methods and the treatment planning system calculated dose values, were no larger than 5 cGy for dose levels up to 2.2 Gy. Signal to noise in triple-channel dose images was found to be similar to signal to noise in single-channel dose images. The accuracy of resulting dose images from the triple- and single-channel methods with inclusion of pre-IR film scan was found to be similar. Results of a comparison of EBT2 data from a kilovoltage depth dose experiment to corresponding Monte Carlo depth dose data produced dose discrepancies of 9.5 ± 12 cGy and 7.6 ± 6 cGy for the single-channel method with inclusion of a pre-IR film scan and the triple-channel method, respectively. EBT2 showed to be energy sensitive at low kilovoltage energies with response differences of 11.9% and 15.6% in the red channel at 2 Gy between 50-225 kVp and 80-225 kVp photon spectra, respectively. We observed that the triple-channel method resulted in non-uniformity corrections of ±1% and consistency values of 0-3 cGy for the batches and dose levels studied. Results of this study indicate that the triple-channel radiochromic film read-out method performs at least as well as the single-channel method with inclusion of a pre-IR film scan, reduces film non-uniformity and saves time with elimination of a pre-IR film scan.

  12. Prediction of triple-charm molecular pentaquarks

    NASA Astrophysics Data System (ADS)

    Chen, Rui; Hosaka, Atsushi; Liu, Xiang

    2017-12-01

    In a one-boson-exchange model, we study molecular states of double-charm baryon [Ξc c(3621 )] and a charmed meson (D and D*). Our model indicates that there exist two possible triple-charm molecular pentaquarks, a Ξc cD state with I (JP)=0 (1 /2-), and a Ξc cD* state with I (JP)=0 (3 /2-), and we do not find bound solutions for isotriplet states. In addition, we also extend our formula to explore Ξc cB¯(*), Ξc cD¯(*), and Ξc cB(*) systems and find more possible heavy flavor molecular pentaquarks, a Ξc cB ¯ state with I (JP)=0 (1 /2-), a Ξc cB¯* state with I (JP)=0 (3 /2-), and Ξc cD¯*/Ξc cB* states with I (JP)=0 (1 /2-). Experimental research for these predicted triple-charm molecular pentaquarks is encouraged.

  13. Laser welding in penetrating keratoplasty and cataract surgery in pediatric patients: early results.

    PubMed

    Buzzonetti, Luca; Capozzi, Paolo; Petrocelli, Gianni; Valente, Paola; Petroni, Sergio; Menabuoni, Luca; Rossi, Francesca; Pini, Roberto

    2013-12-01

    To evaluate the efficacy of diode laser welding to close corneal wounds in penetrating keratoplasty (PKP) and cataract surgery in pediatric patients. Ophthalmology Department, Bambino Gesù Children's Hospital, Rome, Italy. Prospective observational study. Patients had surgery for congenital cataract (Group 1) or femtosecond laser-assisted PKP (Group 2). The surgery was followed by corneal wound closure using diode laser welding of the stroma. In Group 1, no standard suturing was used. In Group 2, the donor button was sutured onto the recipient using 8 single nylon sutures or a 10-0 nylon running suture (12 passages). Laser welding was then used as an adjunct to the traditional suturing procedure. Group 1 comprised 7 eyes (7 patients; mean age 8.1 years ± 5.3 [SD], range 1 to 15 years) and Group 2, 5 eyes (5 patients; mean age 10.6 ± 3.3 years, range 6 to 15 years). The adhesion of the laser-welded tissues was perfect; there were no collateral effects, and restoration of the treated tissues was optimum. Seidel testing showed no wound leakage during the follow-up. Postoperative astigmatism did not change significantly from the first day after cataract surgery and shifted moderately 3 months after PKP. Laser welding of corneal tissue appeared to be safe and effective in children for whom a sutureless surgical procedure is important to reduce the use of anesthesia for suture management, prevent endophthalmitis, and improve the antiamblyopic effect. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Quantitative Analysis of Endothelial Cell Loss in Preloaded Descemet Membrane Endothelial Keratoplasty Grafts.

    PubMed

    Wolle, Meraf A; DeMill, David L; Johnson, Lauren; Lentz, Stephen I; Woodward, Maria A; Mian, Shahzad I

    2017-11-01

    Availability of preloaded Descemet membrane endothelial keratoplasty (pDMEK) tissue may increase acceptance of DMEK in surgical management of endothelial disease. The goal of this study was to determine the safety of pDMEK grafts for 24 hours before surgery by analyzing endothelial cell loss (ECL) using 2 image analysis software programs. A total of 18 cadaveric corneas were prepared for DMEK using a standardized technique and loaded in a modified Jones tube injector. Nine of the corneas were injected into Calcein AM vital dye after 1 minute (controls), and the remaining 9 corneas were left preloaded for 24 hours before injection into vital dye for staining. The stained corneas were imaged using an inverted confocal microscope. ECL was then analyzed and quantified by 2 different graders using 2 image analysis software programs. The control DMEK tissue resulted in 22.0% ± 4.0% ECL compared with pDMEK tissue, which resulted in 19.2% ± 7.2% ECL (P = 0.31). Interobserver agreement was 0.93 for MetaMorph and 0.92 for Fiji. The average time required to process images with MetaMorph was 2 ± 1 minutes and with Fiji was 20 ± 10 minutes. Intraobserver agreement was 0.97 for MetaMorph and 0.93 for Fiji. Preloading DMEK tissue is safe and may provide an alternative technique for tissue distribution and surgery for DMEK. The use of MetaMorph software for quantifying ECL is a novel and accurate imaging method with increased efficiency and reproducibility compared with the previously validated Fiji.

  15. Laser welding in penetrating keratoplasty and cataract surgery of pediatric patients: early results

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Pini, Roberto; Menabuoni, Luca; Malandrini, Alex; Canovetti, Annalisa; Lenzetti, Ivo; Capozzi, Paolo; Valente, Paola; Buzzonetti, Luca

    2013-03-01

    Diode laser welding of ocular tissues is a procedure that enables minimally invasive closure of a corneal wound. This procedure is based on a photothermal effect: a water solution of Indocyanine Green (ICG) is inserted in the surgical wound, in order to stain the corneal tissue walls. The stained tissue is then irradiated with a low power infrared diode laser, delivering laser light through a 300-μm core diameter optical fiber. This procedure enables an immediate closure of the wounds: it is thus possible to reduce or to substitute the use of surgical threads. This is of particular interest in children, because the immediate closure improves refractive outcome and anti-amblyopic effect; moreover this procedure avoids several general anaesthesia for suture management. In this work, we present the first use of diode laser welding procedure in paediatric patients. 5 selected patients underwent cataract surgery (Group 1), while 4 underwent fs-laserassisted penetrating keratoplasty (Group 2). In Group 1 the conventional surgery procedure was performed, while no stitches were used for the closure of the surgical wounds: these were laser welded and immediately closed. In Group 2 the donor button was sutured upon the recipient by 8 single stitches, instead of 16 single stitches or a running suture. The laser welding procedure was performed in order to join the donor tissue to the recipient bed. Objective observations in the follow up study evidenced a perfect adhesion of the laser welded tissues, no collateral effects and an optimal restoration of the treated tissues.

  16. The Big-Bubble Full Femtosecond Laser-Assisted Technique in Deep Anterior Lamellar Keratoplasty.

    PubMed

    Buzzonetti, Luca; Petrocelli, Gianni; Valente, Paola; Iarossi, Giancarlo; Ardia, Roberta; Petroni, Sergio; Parrilla, Rosa

    2015-12-01

    To describe the big-bubble full femtosecond laser-assisted (BBFF) technique, which could be helpful in standardizing the big-bubble technique in deep anterior lamellar keratoplasty (DALK). Ten eyes of 10 consecutive patients affected by keratoconus underwent the BBFF technique using the 150-kHz IntraLase femtosecond laser (Intra-Lase FS Laser; Abbott Medical Optics, Inc., Santa Ana, CA). A 9-mm diameter metal mask with a single fissure 0.7 mm wide oriented at the 12-o'clock position was positioned into the cone, over the laser glass. The laser performed a ring lamellar cut (internal diameter = 3 mm; external diameter = 8 mm) 100 µm above the thinnest point, with the photodisruption effectively occurring only in the corneal stroma corresponding to the fissure to create a deep stromal channel; subsequently, an anterior side cut created an arcuate incision, from the corneal surface to the deep stromal channel on the mask's opening site. The mask was removed and the laser performed a full lamellar cut 200 µm above the thinnest point to create a lamella. After the removal of the lamella, the air needle was inserted into the stromal channel and air was injected to achieve a big bubble. The big bubble was achieved in 9 eyes (all type 1 bubbles) and all procedures were completed as DALK. Preliminary results suggest that the BBFF technique could help in standardizing the big-bubble technique in DALK, reducing the "learning curve" for surgeons who approach this technique and the risks of intraoperative complications. Copyright 2015, SLACK Incorporated.

  17. QCD triple Pomeron coupling from string amplitudes

    NASA Astrophysics Data System (ADS)

    Bialas, A.; Navelet, H.; Peschanski, R.

    1998-06-01

    Using the recent solution of the triple Pomeron coupling in the QCD dipole picture as a closed string amplitude with six legs, its analytical form in terms of hypergeometric functions and numerical value are derived.

  18. The role of taxanes in triple-negative breast cancer: literature review

    PubMed Central

    Mustacchi, Giorgio; De Laurentiis, Michelino

    2015-01-01

    Breast cancer (BC) is the most frequent tumor worldwide. Triple-negative BCs are characterized by the negative estrogen and progesterone receptors and negative HER2, and represent 15% of all BCs. In this review, data on the use of taxanes in triple-negative BCs are analyzed, concluding they are effective in any clinical setting (neoadjuvant, adjuvant, and metastatic). Further, the role of nab-paclitaxel (formulation of albumin-bound paclitaxel) in these tumors is also evaluated. The available data show the clinical potential of nab-paclitaxel based combinations in terms of long-duration response, increased survival, and better quality of life of patients with triple-negative metastatic BC. The ongoing trials will give further information on the better management of this type of tumor. PMID:26273192

  19. Self-assembled RNA-triple-helix hydrogel scaffold for microRNA modulation in the tumour microenvironment

    NASA Astrophysics Data System (ADS)

    Conde, João; Oliva, Nuria; Atilano, Mariana; Song, Hyun Seok; Artzi, Natalie

    2016-03-01

    The therapeutic potential of miRNA (miR) in cancer is limited by the lack of efficient delivery vehicles. Here, we show that a self-assembled dual-colour RNA-triple-helix structure comprising two miRNAs--a miR mimic (tumour suppressor miRNA) and an antagomiR (oncomiR inhibitor)--provides outstanding capability to synergistically abrogate tumours. Conjugation of RNA triple helices to dendrimers allows the formation of stable triplex nanoparticles, which form an RNA-triple-helix adhesive scaffold upon interaction with dextran aldehyde, the latter able to chemically interact and adhere to natural tissue amines in the tumour. We also show that the self-assembled RNA-triple-helix conjugates remain functional in vitro and in vivo, and that they lead to nearly 90% levels of tumour shrinkage two weeks post-gel implantation in a triple-negative breast cancer mouse model. Our findings suggest that the RNA-triple-helix hydrogels can be used as an efficient anticancer platform to locally modulate the expression of endogenous miRs in cancer.

  20. Weighing of risk factors for penetrating keratoplasty graft failure: application of Risk Score System.

    PubMed

    Tourkmani, Abdo Karim; Sánchez-Huerta, Valeria; De Wit, Guillermo; Martínez, Jaime D; Mingo, David; Mahillo-Fernández, Ignacio; Jiménez-Alfaro, Ignacio

    2017-01-01

    To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases), incomplete medical notes (5 cases) and follow-up less than 1y (3 cases). We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure ( P <0.05). Multivariate logistic regression analysis showed no statistically significant relationship ( P >0.05) between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant ( P <0.05), although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y.

  1. Weighing of risk factors for penetrating keratoplasty graft failure: application of Risk Score System

    PubMed Central

    Tourkmani, Abdo Karim; Sánchez-Huerta, Valeria; De Wit, Guillermo; Martínez, Jaime D.; Mingo, David; Mahillo-Fernández, Ignacio; Jiménez-Alfaro, Ignacio

    2017-01-01

    AIM To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. METHODS The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases), incomplete medical notes (5 cases) and follow-up less than 1y (3 cases). We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. RESULTS Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure (P<0.05). Multivariate logistic regression analysis showed no statistically significant relationship (P>0.05) between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant (P<0.05), although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. CONCLUSION After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y. PMID:28393027

  2. Automated lamellar therapeutic keratoplasty with fibrin adhesive in the treatment of anterior corneal opacities.

    PubMed

    Hashemi, Hassan; Dadgostar, Alhan

    2011-06-01

    To assess the visual outcome of using fibrin adhesive in automated lamellar therapeutic keratoplasty with a microkeratome in the treatment of anterior corneal opacities. In this prospective noncomparative clinical trial, surgery was done on 10 eyes belonging to 9 patients with anterior stromal opacity (macular dystrophy, spheroidal degeneration, scarring because of advanced recurrent pterygium, refractive surgery, or trauma). Depending on the depth of the opacity, a 130- or 250-μm flap was removed from the recipient cornea using a microkeratome. Then, a thin layer of fibrin adhesive was spread over the bed, and a lenticule with the same thickness, created from the donor cornea, was positioned in place. After allowing the glue to set for about 5 minutes, a bandage contact lens was placed over the cornea, which was removed 7-10 days postoperatively. All corneas healed properly, and none required suturing or reoperation. During the follow-up period, no inflammation or rejection was observed. The donor cornea and the donor-recipient interface remained clear in all cases. The mean of best contact lens-corrected visual acuity improved from 1.14 ± 0.53 to 0.51 ± 0.23 in the logarithm of the minimum angle of resolution scale. The fibrin glue can provide safe and effective attachment needed in automated lamellar therapeutic keratectomy and obviates the need for suturing. However, it requires improvement for easier and safer use in ophthalmology.

  3. Software-Enabled Project Management Techniques and Their Relationship to the Triple Constraints

    ERIC Educational Resources Information Center

    Elleh, Festus U.

    2013-01-01

    This study investigated the relationship between software-enabled project management techniques and the triple constraints (time, cost, and scope). There was the dearth of academic literature that focused on the relationship between software-enabled project management techniques and the triple constraints (time, cost, and scope). Based on the gap…

  4. [Triple-negative breast carcinoma--rewiev of current literature].

    PubMed

    Rubovszky, Gábor; Udvarhelyi, Nóra; Horváth, Zsolt; Láng, István; Kásler, Miklós

    2010-12-01

    Breast cancer is one of the most common malignancies in women. Approximately 15% of cases belong to the triple-negative breast cancer (TNBC) group, in which no estrogen/progesterone receptors, or HER2 expression is detected. The unfavorable prognosis of this group of patients, as well as the lack of effective targeted therapy makes TNBC the subject of intensive research. In the present study, we searched PubMed for publications from January 2007 to June 2009 with the following key-words in addition to "breast cancer" and "triple negative": "epidemiology" or "gene-profile" or "predictive" or "prognostic" or "therapy" or "review". A total of 513 publications were identified. Relevant references were also reviewed. Beyond the well-known facts that TNBC affects younger patients, and is more common among Afro- or Hispano-Americans with lower socioeconomic status, hormonal environment and obesity emerged as potential etiologic factors. TNBC is not a homogenous disease. It can be further sub-classified based on histomorphologic features and immunohistochemistry. Hereditary BRCA1 mutations as well as acquired BRCA1 disfunction are described to be common in TNBC. Previously, many investigators considered TNBC to be identical to a subgroup called basal-like breast cancer defined by gene expression micro-array technology, but in the light of more recent findings, this view is no longer accepted by most investigators. Several large studies provide evidence that triple negativity, per se, is an independent adverse prognostic factor, in spite of the fact that approximately 10% of TNBC patients have a good prognosis. The therapy of choice for TNBC is systemic chemotherapy. Promising novel targeted chemotherapeutic agents include PARP1 inhibitors, a new group of compounds exploiting the defective DNA repair machinery. Rubovszky G, Udvarhelyi N, Horváth Z, Láng I, Kásler M. Triple negative breast carcinoma - rewiev of current literature.

  5. Rheumatoid Arthritis Treatment After Methotrexate: The Durability of Triple Therapy Versus Etanercept.

    PubMed

    Peper, Shana M; Lew, Robert; Mikuls, Ted; Brophy, Mary; Rybin, Denis; Wu, Hongseng; O'Dell, James

    2017-10-01

    Although it is common for rheumatologists to initiate biologic agents after failure of methotrexate monotherapy in rheumatoid arthritis (RA), ample data support the initial use of combinations of conventional therapies in this clinical scenario. Our study explores the durability of triple therapy (methotrexate, sulfasalazine, and hydroxychloroquine) versus methotrexate-etanercept in RA. RA patients with suboptimal response to methotrexate (n = 353) were randomized to either triple therapy or methotrexate-etanercept therapy in a 48-week, double-blinded, noninferiority trial. Patients without clinical improvement at 24 weeks were switched to the alternative treatment. Of the total, 289 participated in followup. We report treatment durability, Disease Activity Score in 28 joints (DAS28), and other measures during an open-label extension for an additional period up to 72 weeks. Mean ± SD duration of open-label followup was 11 ± 6 months. The likelihood of continuing conventional therapy at 1 year was 78% for triple therapy versus 63% for methotrexate-etanercept, with most treatment changes occurring at the start of followup. More patients changed from methotrexate-etanercept to triple therapy than from triple therapy to methotrexate-etanercept (P = 0.005). DAS28 scores and other disease activity measures were not different for the 2 treatments and were stable during followup. In RA patients with suboptimal methotrexate response randomized to receive triple therapy or methotrexate-etanercept, the former was found to be significantly more durable. Given cost differences and similar outcomes, the variable durability demonstrated provides additional evidence supporting conventional combinations over biologic agent combinations as the first choice after methotrexate inadequate response. © 2017, American College of Rheumatology.

  6. Design of triple-band polarization controlled terahertz metamaterial absorber

    NASA Astrophysics Data System (ADS)

    Wang, Ben-Xin; Xie, Qin; Dong, Guangxi; Huang, Wei-Qing

    2018-02-01

    A kind of triple-band polarization tunable terahertz absorber based on a metallic mirror and a metallic patch structure with two indentations spaced by an insulating medium layer is presented. Results prove that three near-perfect absorption peaks with average absorption coefficients of 98.25% are achieved when the polarization angle is equal to zero, and their absorptivities gradually decrease (and even disappear) by increasing the angle of polarization. When the polarization angle is increased to 90°, three new resonance modes with average absorption rates of 96.59% can be obtained. The field distributions are given to reveal the mechanisms of the triple-band absorption and the polarization tunable characteristics. Moreover, by introducing photosensitive silicon materials (its conductivity can be changed by the pump beam) in the indentations of the patch structure, the number of resonance peaks of the device can be actively tuned from triple-band to dual-band. The presented absorbers have potential applications, such as controlling thermal emissivity, and detection of polarization direction of the incident waves.

  7. Cycle simulation of the low-temperature triple-effect absorption chiller with vapor compression unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J.S.; Lee, H.

    1999-07-01

    The construction of a triple-effect absorption chiller machine using the lithium bromide-water solution as a working fluid is strongly limited by corrosion problems caused by the high generator temperature. In this work, three new cycles having the additional vapor compression units were suggested in order to lower the generator temperature of a triple-effect absorption chiller. Each new cycle has one compressor located at the different position which was used to elevate the pressure of the refrigerant vapor. Computer simulations were carried out in order to examine both the basic triple-effect cycle and three new cycles. All types of triple-effect absorptionmore » chiller cycles were found to be able to lower the temperature of high-temperature generator to the more favorable operation range. The COPs of three cycles calculated by considering the additional compressor works showed a small level of decrease or increase compared with that of the basic triple-effect cycle. Consequently, a low-temperature triple-effect absorption chiller can be possibly constructed by adapting one of three new cycles. A great advantage of these new cycles over the basic one is that the conventionally used lithium bromide-water solution can be successfully used as a working fluid without the danger of corrosion.« less

  8. On universality of scaling law describing roughness of triple line.

    PubMed

    Bormashenko, Edward; Musin, Albina; Whyman, Gene; Barkay, Zahava; Zinigrad, Michael

    2015-01-01

    The fine structure of the three-phase (triple) line was studied for different liquids, various topographies of micro-rough substrates and various wetting regimes. Wetting of porous and pillar-based micro-scaled polymer surfaces was investigated. The triple line was visualized with the environmental scanning electron microscope and scanning electron microscope for the "frozen" triple lines. The value of the roughness exponent ζ for water (ice)/rough polymer systems was located within 0.55-0.63. For epoxy glue/rough polymer systems somewhat lower values of the exponent, 0.42 < ζ < 0.54, were established. The obtained values of ζ were close for the Cassie and Wenzel wetting regimes, different liquids, and different substrates' topographies. Thus, the above values of the exponent are to a great extent universal. The switch of the exponent, when the roughness size approaches to the correlation length of the defects, is also universal.

  9. 19p13.1 is a triple-negative-specific breast cancer susceptibility locus.

    PubMed

    Stevens, Kristen N; Fredericksen, Zachary; Vachon, Celine M; Wang, Xianshu; Margolin, Sara; Lindblom, Annika; Nevanlinna, Heli; Greco, Dario; Aittomäki, Kristiina; Blomqvist, Carl; Chang-Claude, Jenny; Vrieling, Alina; Flesch-Janys, Dieter; Sinn, Hans-Peter; Wang-Gohrke, Shan; Nickels, Stefan; Brauch, Hiltrud; Ko, Yon-Dschun; Fischer, Hans-Peter; Schmutzler, Rita K; Meindl, Alfons; Bartram, Claus R; Schott, Sarah; Engel, Christoph; Godwin, Andrew K; Weaver, Joellen; Pathak, Harsh B; Sharma, Priyanka; Brenner, Hermann; Müller, Heiko; Arndt, Volker; Stegmaier, Christa; Miron, Penelope; Yannoukakos, Drakoulis; Stavropoulou, Alexandra; Fountzilas, George; Gogas, Helen J; Swann, Ruth; Dwek, Miriam; Perkins, Annie; Milne, Roger L; Benítez, Javier; Zamora, María Pilar; Pérez, José Ignacio Arias; Bojesen, Stig E; Nielsen, Sune F; Nordestgaard, Børge G; Flyger, Henrik; Guénel, Pascal; Truong, Thérèse; Menegaux, Florence; Cordina-Duverger, Emilie; Burwinkel, Barbara; Marmé, Frederick; Schneeweiss, Andreas; Sohn, Christof; Sawyer, Elinor; Tomlinson, Ian; Kerin, Michael J; Peto, Julian; Johnson, Nichola; Fletcher, Olivia; Dos Santos Silva, Isabel; Fasching, Peter A; Beckmann, Matthias W; Hartmann, Arndt; Ekici, Arif B; Lophatananon, Artitaya; Muir, Kenneth; Puttawibul, Puttisak; Wiangnon, Surapon; Schmidt, Marjanka K; Broeks, Annegien; Braaf, Linde M; Rosenberg, Efraim H; Hopper, John L; Apicella, Carmel; Park, Daniel J; Southey, Melissa C; Swerdlow, Anthony J; Ashworth, Alan; Orr, Nicholas; Schoemaker, Minouk J; Anton-Culver, Hoda; Ziogas, Argyrios; Bernstein, Leslie; Dur, Christina Clarke; Shen, Chen-Yang; Yu, Jyh-Cherng; Hsu, Huan-Ming; Hsiung, Chia-Ni; Hamann, Ute; Dünnebier, Thomas; Rüdiger, Thomas; Ulmer, Hans Ulrich; Pharoah, Paul P; Dunning, Alison M; Humphreys, Manjeet K; Wang, Qin; Cox, Angela; Cross, Simon S; Reed, Malcom W; Hall, Per; Czene, Kamila; Ambrosone, Christine B; Ademuyiwa, Foluso; Hwang, Helena; Eccles, Diana M; Garcia-Closas, Montserrat; Figueroa, Jonine D; Sherman, Mark E; Lissowska, Jolanta; Devilee, Peter; Seynaeve, Caroline; Tollenaar, Rob A E M; Hooning, Maartje J; Andrulis, Irene L; Knight, Julia A; Glendon, Gord; Mulligan, Anna Marie; Winqvist, Robert; Pylkäs, Katri; Jukkola-Vuorinen, Arja; Grip, Mervi; John, Esther M; Miron, Alexander; Alnæs, Grethe Grenaker; Kristensen, Vessela; Børresen-Dale, Anne-Lise; Giles, Graham G; Baglietto, Laura; McLean, Catriona A; Severi, Gianluca; Kosel, Matthew L; Pankratz, V S; Slager, Susan; Olson, Janet E; Radice, Paolo; Peterlongo, Paolo; Manoukian, Siranoush; Barile, Monica; Lambrechts, Diether; Hatse, Sigrid; Dieudonne, Anne-Sophie; Christiaens, Marie-Rose; Chenevix-Trench, Georgia; Beesley, Jonathan; Chen, Xiaoqing; Mannermaa, Arto; Kosma, Veli-Matti; Hartikainen, Jaana M; Soini, Ylermi; Easton, Douglas F; Couch, Fergus J

    2012-04-01

    The 19p13.1 breast cancer susceptibility locus is a modifier of breast cancer risk in BRCA1 mutation carriers and is also associated with the risk of ovarian cancer. Here, we investigated 19p13.1 variation and risk of breast cancer subtypes, defined by estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor-2 (HER2) status, using 48,869 breast cancer cases and 49,787 controls from the Breast Cancer Association Consortium (BCAC). Variants from 19p13.1 were not associated with breast cancer overall or with ER-positive breast cancer but were significantly associated with ER-negative breast cancer risk [rs8170 OR, 1.10; 95% confidence interval (CI), 1.05-1.15; P = 3.49 × 10(-5)] and triple-negative (ER-, PR-, and HER2-negative) breast cancer (rs8170: OR, 1.22; 95% CI, 1.13-1.31; P = 2.22 × 10(-7)). However, rs8170 was no longer associated with ER-negative breast cancer risk when triple-negative cases were excluded (OR, 0.98; 95% CI, 0.89-1.07; P = 0.62). In addition, a combined analysis of triple-negative cases from BCAC and the Triple Negative Breast Cancer Consortium (TNBCC; N = 3,566) identified a genome-wide significant association between rs8170 and triple-negative breast cancer risk (OR, 1.25; 95% CI, 1.18-1.33; P = 3.31 × 10(-13)]. Thus, 19p13.1 is the first triple-negative-specific breast cancer risk locus and the first locus specific to a histologic subtype defined by ER, PR, and HER2 to be identified. These findings provide convincing evidence that genetic susceptibility to breast cancer varies by tumor subtype and that triple-negative tumors and other subtypes likely arise through distinct etiologic pathways. ©2012 AACR.

  10. Triple helical DNA in a duplex context and base pair opening

    PubMed Central

    Esguerra, Mauricio; Nilsson, Lennart; Villa, Alessandra

    2014-01-01

    It is fundamental to explore in atomic detail the behavior of DNA triple helices as a means to understand the role they might play in vivo and to better engineer their use in genetic technologies, such as antigene therapy. To this aim we have performed atomistic simulations of a purine-rich antiparallel triple helix stretch of 10 base triplets flanked by canonical Watson–Crick double helices. At the same time we have explored the thermodynamic behavior of a flipping Watson–Crick base pair in the context of the triple and double helix. The third strand can be accommodated in a B-like duplex conformation. Upon binding, the double helix changes shape, and becomes more rigid. The triple-helical region increases its major groove width mainly by oversliding in the negative direction. The resulting conformations are somewhere between the A and B conformations with base pairs remaining almost perpendicular to the helical axis. The neighboring duplex regions maintain a B DNA conformation. Base pair opening in the duplex regions is more probable than in the triplex and binding of the Hoogsteen strand does not influence base pair breathing in the neighboring duplex region. PMID:25228466

  11. Trimerization and Triple Helix Stabilization of the Collagen XIX NC2 Domain*

    PubMed Central

    Boudko, Sergei P.; Engel, Jürgen; Bächinger, Hans Peter

    2008-01-01

    The mechanisms of chain selection and assembly of fibril-associated collagens with interrupted triple helices (FACITs) must differ from that of fibrillar collagens, since they lack the characteristic C-propeptide. We analyzed two carboxyl-terminal noncollagenous domains, NC2 and NC1, of collagen XIX as potential trimerization units and found that NC2 forms a stable trimer and substantially stabilizes a collagen triple helix attached to either end. In contrast, the NC1 domain requires formation of an adjacent collagen triple helix to form interchain disulfide bridges. The NC2 domain of collagen XIX and probably of other FACITs is responsible for chain selection and trimerization. PMID:18845531

  12. The psychiatric phenotype in triple X syndrome: New hypotheses illustrated in two cases

    PubMed Central

    Otter, Maarten; Schrander-Stumpel, Constance T. R. M.; Didden, Robert; Curfs, Leopold M. G.

    2012-01-01

    Background: Triple X syndrome (47,XXX or trisomy X) is a relatively frequent cytogenetic condition with a large variety of physical and behavioural phenotypes. Method: Two adult patients with a triple X karyotype are described. Results: Their karyotype was unknown until some years ago. What these patients have in common is that they were diagnosed with a broader autism phenotype, they were sexually abused, they suffer from psychotic illness and they show challenging behaviour, suicidality and a decline in occupational capacity. Discussion: These gene-environment interactions are discussed. Gene-environment interactions may explain the variety of behavioural and psychiatric phenotypes in triple X syndrome. Ongoing atypical development in adults is hypothesized. Conclusions: Gene-environment interactions and ongoing atypical development in adults should be taken into account in research concerning the psychiatric phenotype of developmental disorders, especially those involving triple X syndrome. PMID:22582855

  13. Triple X syndrome and puberty: focus on the hypothalamus-hypophysis-gonad axis.

    PubMed

    Stagi, Stefano; di Tommaso, Mariarosaria; Scalini, Perla; Lapi, Elisabetta; Losi, Stefania; Bencini, Erica; Masoni, Fabrizio; Dosa, Laura; Becciani, Sabrina; de Martino, Maurizio

    2016-06-01

    To evaluate the hypothalamus-hypophysis-gonad axis in a cohort of children and adolescents with nonmosaic triple X syndrome. Cross-sectional study with retrospective analysis. University pediatric hospital. Fifteen prepubertal subjects (median age 9.0 years, range 6.9-11.9 years) with nonmosaic triple X syndrome and age- and pubertal-matched control group (30 girls, median age 9.1 y, range 6.9-11.6 years). None. We evaluated FSH, LH, and E2 levels and performed an autoimmunity screening as well as a pelvic ultrasonography and an LH-releasing hormone stimulation test. All triple X patients (with and without pubertal signs) showed a pubertal LH peak level that was significantly different from controls. Triple X patients showed increased basal and peak FSH and LH values compared with control subjects. However, the mean E2 level was significantly lower than control subjects. However, triple X patients showed reduced DHEAS levels and reduced inhibin levels compared with control subjects. Finally, triple X patients had a significantly reduced ovarian volume compared with control subjects, in both prepubertal and pubertal patients. Triple X patients showed premature activation of the GnRH pulse generator, even without puberty signs. Both basal and peak LH and FSH levels were higher than in control subjects, and E2 and inhibin levels and ovarian volume were reduced, which led to a reduced gonadal function. Other studies and a longitudinal evaluation is necessary to better understand the endocrinologic features of these subjects. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  14. Tidal breakup of triple stars in the Galactic Centre

    NASA Astrophysics Data System (ADS)

    Fragione, Giacomo; Gualandris, Alessia

    2018-04-01

    The last decade has seen the detection of fast moving stars in the Galactic halo, the so-called hypervelocity stars (HVSs). While the bulk of this population is likely the result of a close encounter between a stellar binary and the supermassive black hole (MBH) in the Galactic Centre (GC), other mechanims may contribute fast stars to the sample. Few observed HVSs show apparent ages, which are shorter than the flight time from the GC, thereby making the binary disruption scenario unlikely. These stars may be the result of the breakup of a stellar triple in the GC, which led to the ejection of a hypervelocity binary (HVB). If such binary evolves into a blue straggler star due to internal processes after ejection, a rejuvenation is possible that make the star appear younger once detected in the halo. A triple disruption may also be responsible for the presence of HVBs, of which one candidate has now been observed. We present a numerical study of triple disruptions by the MBH in the GC and find that the most likely outcomes are the production of single HVSs and single/binary stars bound to the MBH, while the production of HVBs has a probability ≲ 1 per cent regardless of the initial parameters. Assuming a triple fraction of ≈ 10 per cent results in an ejection rate of ≲ 1 Gyr - 1, insufficient to explain the sample of HVSs with lifetimes shorter than their flight time. We conclude that alternative mechanisms are responsible for the origin of such objects and HVBs in general.

  15. Evaluating the approach run of class F11 visually impaired athletes in triple and long jumps.

    PubMed

    Theodorou, Apostolos; Skordilis, Emmanouil

    2012-04-01

    The present study examined stride pattern characteristics of Class F11 visually impaired long jumpers and triple jumpers. Athletes demonstrated initial ascending footfall variability followed by descending variability, on the second (long jumpers) and third (triple jumpers) stride prior to take-off, at a mean distance of 6.26 m (long jumpers) and 7.36 m (triple jumpers) from the take-off board. Toe-board-distance variability reached a maximum value of 0.36 m and 0.38 m for the long and triple jump, respectively. Last stride toe-board-distance variability was 0.29 m (long jump) and 0.25 m (triple jump). Class F11 visually impaired athletes exhibit regulation of goal-directed gait analogous to that of non-visually impaired athletes.

  16. Integrating Compassionate, Collaborative Care (the "Triple C") Into Health Professional Education to Advance the Triple Aim of Health Care.

    PubMed

    Lown, Beth A; McIntosh, Sharrie; Gaines, Martha E; McGuinn, Kathy; Hatem, David S

    2016-03-01

    Empathy and compassion provide an important foundation for effective collaboration in health care. Compassion (the recognition of and response to the distress and suffering of others) should be consistently offered by health care professionals to patients, families, staff, and one another. However, compassion without collaboration may result in uncoordinated care, while collaboration without compassion may result in technically correct but depersonalized care that fails to meet the unique emotional and psychosocial needs of all involved. Providing compassionate, collaborative care (CCC) is critical to achieving the "triple aim" of improving patients' health and experiences of care while reducing costs. Yet, values and skills related to CCC (or the "Triple C") are not routinely taught, modeled, and assessed across the continuum of learning and practice. To change this paradigm, an interprofessional group of experts recently recommended approaches and a framework for integrating CCC into health professional education and postgraduate training as well as clinical care. In this Perspective, the authors describe how the Triple C framework can be integrated and enhance existing competency standards to advance CCC across the learning and practice continuum. They also discuss strategies for partnering with patients and families to improve health professional education and health care design and delivery through quality improvement projects. They emphasize that compassion and collaboration are important sources of professional, patient, and family satisfaction as well as critical aspects of professionalism and person-centered, relationship-based high-quality care.

  17. Isolation and characterization of a uranium(VI)-nitride triple bond

    NASA Astrophysics Data System (ADS)

    King, David M.; Tuna, Floriana; McInnes, Eric J. L.; McMaster, Jonathan; Lewis, William; Blake, Alexander J.; Liddle, Stephen T.

    2013-06-01

    The nature and extent of covalency in uranium bonding is still unclear compared with that of transition metals, and there is great interest in studying uranium-ligand multiple bonds. Although U=O and U=NR double bonds (where R is an alkyl group) are well-known analogues to transition-metal oxo and imido complexes, the uranium(VI)-nitride triple bond has long remained a synthetic target in actinide chemistry. Here, we report the preparation of a uranium(VI)-nitride triple bond. We highlight the importance of (1) ancillary ligand design, (2) employing mild redox reactions instead of harsh photochemical methods that decompose transiently formed uranium(VI) nitrides, (3) an electrostatically stabilizing sodium ion during nitride installation, (4) selecting the right sodium sequestering reagent, (5) inner versus outer sphere oxidation and (6) stability with respect to the uranium oxidation state. Computational analyses suggest covalent contributions to U≡N triple bonds that are surprisingly comparable to those of their group 6 transition-metal nitride counterparts.

  18. Shaping planetary nebulae with jets in inclined triple stellar systems

    NASA Astrophysics Data System (ADS)

    Akashi, Muhammad; Soker, Noam

    2017-08-01

    We conduct three-dimensional hydrodynamical simulations of two opposite jets launched obliquely to the orbital plane around an asymptotic giant branch (AGB) star and within its dense wind, and demonstrate the formation of a 'messy' planetary nebula (PN), namely a PN lacking any type of symmetry (I.e. highly irregular). In building the initial conditions, we assume that a tight binary system orbits the AGB star and that the orbital plane of the tight binary system is inclined to the orbital plane of the binary system and the AGB star (the triple system plane). We further assume that the accreted mass on to the tight binary system forms an accretion disc around one of the stars and that the plane of the disc is tilted to the orbital plane of the triple system. The highly asymmetrical and filamentary structures that we obtain support the notion that messy PNe might be shaped by triple stellar systems.

  19. Pedagogical alternatives for triple integrals: moving towards more inclusive and personalized learning

    NASA Astrophysics Data System (ADS)

    Tisdell, Christopher C.

    2018-07-01

    This paper is based on the presumption that teaching multiple ways to solve the same problem has academic and social value. In particular, we argue that such a multifaceted approach to pedagogy moves towards an environment of more inclusive and personalized learning. From a mathematics education perspective, our discussion is framed around pedagogical approaches to triple integrals seen in a standard multivariable calculus curriculum. We present some critical perspectives regarding the dominant and long-standing approach to the teaching of triple integrals currently seen in hegemonic calculus textbooks; and we illustrate the need for more diverse pedagogical methods. Finally, we take a constructive position by introducing a new and alternate pedagogical approach to solve some of the classical problems involving triple integrals from the literature through a simple application of integration by parts. This pedagogical alternative for triple integrals is designed to question the dominant one-size-fits-all approach of rearranging the order of integration and the privileging of graphical methods; and to enable a shift towards a more inclusive, enhanced and personalized learning experience.

  20. Brown Dwarf Binaries from Disintegrating Triple Systems

    NASA Astrophysics Data System (ADS)

    Reipurth, Bo; Mikkola, Seppo

    2015-04-01

    Binaries in which both components are brown dwarfs (BDs) are being discovered at an increasing rate, and their properties may hold clues to their origin. We have carried out 200,000 N-body simulations of three identical stellar embryos with masses drawn from a Chabrier IMF and embedded in a molecular core. The bodies are initially non-hierarchical and undergo chaotic motions within the cloud core, while accreting using Bondi-Hoyle accretion. The coupling of dynamics and accretion often leads to one or two dominant bodies controlling the center of the cloud core, while banishing the other(s) to the lower-density outskirts, leading to stunted growth. Eventually each system transforms either to a bound hierarchical configuration or breaks apart into separate single and binary components. The orbital motion is followed for 100 Myr. In order to illustrate 200,000 end-states of such dynamical evolution with accretion, we introduce the “triple diagnostic diagram,” which plots two dimensionless numbers against each other, representing the binary mass ratio and the mass ratio of the third body to the total system mass. Numerous freefloating BD binaries are formed in these simulations, and statistical properties are derived. The separation distribution function is in good correspondence with observations, showing a steep rise at close separations, peaking around 13 AU and declining more gently, reaching zero at separations greater than 200 AU. Unresolved BD triple systems may appear as wider BD binaries. Mass ratios are strongly peaked toward unity, as observed, but this is partially due to the initial assumptions. Eccentricities gradually increase toward higher values, due to the lack of viscous interactions in the simulations, which would both shrink the orbits and decrease their eccentricities. Most newborn triple systems are unstable and while there are 9209 ejected BD binaries at 1 Myr, corresponding to about 4% of the 200,000 simulations, this number has grown to

  1. Numerical Study of Buoyancy and Different Diffusion Effects on the Structure and Dynamics of Triple Flames

    NASA Technical Reports Server (NTRS)

    Chen, Jyh-Yuan; Echekki, Tarek

    2001-01-01

    Numerical simulations of 2-D triple flames under gravity force have been implemented to identify the effects of gravity on triple flame structure and propagation properties and to understand the mechanisms of instabilities resulting from both heat release and buoyancy effects. A wide range of gravity conditions, heat release, and mixing widths for a scalar mixing layer are computed for downward-propagating (in the same direction with the gravity vector) and upward-propagating (in the opposite direction of the gravity vector) triple flames. Results of numerical simulations show that gravity strongly affects the triple flame speed through its contribution to the overall flow field. A simple analytical model for the triple flame speed, which accounts for both buoyancy and heat release, is developed. Comparisons of the proposed model with the numerical results for a wide range of gravity, heat release and mixing width conditions, yield very good agreement. The analysis shows that under neutral diffusion, downward propagation reduces the triple flame speed, while upward propagation enhances it. For the former condition, a critical Froude number may be evaluated, which corresponds to a vanishing triple flame speed. Downward-propagating triple flames at relatively strong gravity effects have exhibited instabilities. These instabilities are generated without any artificial forcing of the flow. Instead disturbances are initiated by minute round-off errors in the numerical simulations, and subsequently amplified by instabilities. A linear stability analysis on mean profiles of stable triple flame configurations have been performed to identify the most amplified frequency in spatially developed flows. The eigenfunction equations obtained from the linearized disturbance equations are solved using the shooting method. The linear stability analysis yields reasonably good agreements with the observed frequencies of the unstable triple flames. The frequencies and amplitudes of

  2. SIKA—the multiplexing cold-neutron triple-axis spectrometer at ANSTO

    NASA Astrophysics Data System (ADS)

    Wu, C.-M.; Deng, G.; Gardner, J. S.; Vorderwisch, P.; Li, W.-H.; Yano, S.; Peng, J.-C.; Imamovic, E.

    2016-10-01

    SIKA is a new cold-neutron triple-axis spectrometer receiving neutrons from the cold source CG4 of the 20MW Open Pool Australian Light-water reactor. As a state-of-the-art triple-axis spectrometer, SIKA is equipped with a large double-focusing pyrolytic graphite monochromator, a multiblade pyrolytic graphite analyser and a multi-detector system. In this paper, we present the design, functions, and capabilities of SIKA, and discuss commissioning experimental results from powder and single-crystal samples to demonstrate its performance.

  3. Discovering Steiner Triple Systems through Problem Solving

    ERIC Educational Resources Information Center

    Sriraman, Bharath

    2004-01-01

    An attempt to implement problem solving as a teacher of ninth grade algebra is described. The problems selected were not general ones, they involved combinations and represented various situations and were more complex which lead to the discovery of Steiner triple systems.

  4. Normal range of hepatic fat fraction on dual- and triple-echo fat quantification MR in children.

    PubMed

    Shin, Hyun Joo; Kim, Hyun Gi; Kim, Myung-Joon; Koh, Hong; Kim, Ha Yan; Roh, Yun Ho; Lee, Mi-Jung

    2015-01-01

    To evaluate hepatic fat fraction on dual- and triple-echo gradient-recalled echo MRI sequences in healthy children. We retrospectively reviewed the records of children in a medical check-up clinic from May 2012 to November 2013. We excluded children with abnormal laboratory findings or those who were overweight. Hepatic fat fraction was measured on dual- and triple-echo sequences using 3T MRI. We compared fat fractions using the Wilcoxon signed rank test and the Bland-Altman 95% limits of agreement. The correlation between fat fractions and clinical and laboratory findings was evaluated using Spearman's correlation test, and the cut-off values of fat fractions for diagnosing fatty liver were obtained from reference intervals. In 54 children (M:F = 26:28; 5-15 years; mean 9 years), the dual fat fraction (0.1-8.0%; median 1.6%) was not different from the triple fat fraction (0.4-6.5%; median 2.7%) (p = 0.010). The dual- and triple-echo fat fractions showed good agreement using a Bland-Altman plot (-0.6 ± 2.8%). Eight children (14.8%) on dual-echo sequences and six (11.1%) on triple-echo sequences had greater than 5% fat fraction. From these children, six out of eight children on dual-echo sequences and four out of six children on triple-echo sequences had a 5-6% hepatic fat fraction. When using a cut-off value of a 6% fat fraction derived from a reference interval, only 3.7% of children were diagnosed with fatty liver. There was no significant correlation between clinical and laboratory findings with dual and triple-echo fat fractions. Dual fat fraction was not different from triple fat fraction. We suggest a cut-off value of a 6% fat fraction is more appropriate for diagnosing fatty liver on both dual- and triple-echo sequences in children.

  5. Triple-phase helical computed tomography in dogs with solid splenic masses

    PubMed Central

    KUTARA, Kenji; SEKI, Mamiko; ISHIGAKI, Kumiko; TESHIMA, Kenji; ISHIKAWA, Chieko; KAGAWA, Yumiko; EDAMURA, Kazuya; NAKAYAMA, Tomohiro; ASANO, Kazushi

    2017-01-01

    We investigated the utility of triple-phase helical computed tomography (CT) in differentiating between benign and malignant splenic masses in dogs. Forty-two dogs with primary splenic masses underwent triple-phase helical CT scanning (before administration of contrast, and in the arterial phase, portal venous phase, and delayed phase) prior to splenectomy. Tissue specimens were sent for pathological diagnosis; these included hematomas (n=14), nodular hyperplasias (n=12), hemangiosarcomas (n=11), and undifferentiated sarcomas (n=5). The CT findings were compared with the histological findings. Nodular hyperplasia significantly displayed a homogeneous normal enhancement pattern in all phases. Hemangiosarcoma displayed 2 significant contrast-enhancement patterns, including a homogeneous pattern of poor enhancement in all phases, and a heterogeneous remarkable enhancement pattern in the arterial and portal venous phases. Hematoma and undifferentiated sarcoma displayed a heterogeneous normal enhancement pattern in all phases. The contrast-enhanced volumetric ratios of hematoma tended to be greater than those of undifferentiated sarcoma. Our study demonstrated that the characteristic findings on triple-phase helical CT could be useful for the preoperative differentiation of hematoma, nodular hyperplasia, hemangiosarcoma, and undifferentiated sarcoma in dogs. Triple-phase helical CT may be a useful diagnostic tool in dogs with splenic masses. PMID:28993600

  6. The effect of increasing strength and approach velocity on triple jump performance.

    PubMed

    Allen, Sam J; Yeadon, M R Fred; King, Mark A

    2016-12-08

    The triple jump is an athletic event comprising three phases in which the optimal phase ratio (the proportion of each phase to the total distance jumped) is unknown. This study used a planar whole body torque-driven computer simulation model of the ground contact parts of all three phases of the triple jump to investigate the effect of strength and approach velocity on optimal performance. The strength and approach velocity of the simulation model were each increased by up to 30% in 10% increments from baseline data collected from a national standard triple jumper. Increasing strength always resulted in an increased overall jump distance. Increasing approach velocity also typically resulted in an increased overall jump distance but there was a point past which increasing approach velocity without increasing strength did not lead to an increase in overall jump distance. Increasing both strength and approach velocity by 10%, 20%, and 30% led to roughly equivalent increases in overall jump distances. Distances ranged from 14.05m with baseline strength and approach velocity, up to 18.49m with 30% increases in both. Optimal phase ratios were either hop-dominated or balanced, and typically became more balanced when the strength of the model was increased by a greater percentage than its approach velocity. The range of triple jump distances that resulted from the optimisation process suggests that strength and approach velocity are of great importance for triple jump performance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Reversible “triple-Q” elastic field structures in a chiral magnet

    PubMed Central

    Hu, Yangfan; Wang, Biao

    2016-01-01

    The analytical solution of the periodic elastic fields in chiral magnets caused by presence of periodically distributed eigenstrains is obtained. For the skyrmion phase, both the periodic displacement field and the stress field are composed of three “triple-Q” structures with different wave numbers. The periodic displacement field, obtained by combining the three “triple-Q” displacement structures, is found to have the same lattice vectors with the magnetic skyrmion lattice. We find that for increasing external magnetic field, one type of “triple-Q” displacement structure and stress structure undergo a “configurational reversal”, where the initial and the final field configuration share similar pattern but with opposite direction of all the field vectors. The solution obtained is of fundamental significance for understanding the emergent mechanical properties of skyrmions in chiral magnets. PMID:27457629

  8. Acoustic radiation force impulse elastography in evaluation of triple-negative breast cancer: A preliminary experience.

    PubMed

    Wan, Jing; Wu, Rong; Yao, Minghua; Xu, Guang; Liu, Hui; Pu, Huan; Xiang, Lihua; Zhang, Shupin

    2018-05-19

    To assess the elastographic features of triple-negative breast cancers and evaluate the diagnostic value of acoustic radiation force impulse imaging (ARFI) for the characterization of triple-negative breast cancers. This study analyzed data from 234 women with breast cancer. Patients were categorized into three groups; 1) triple-negative breast cancers (n = 48); 2) ER-positive tumors (n = 128) and 3) HER2-positive tumors (n = 58). Mean tumor stiffness was evaluated by virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ) and quantified as both qualitative scores (1-5) and shear wave velocity (SWV) (m/s). The relationship between mean SWV and tumor parameters, including tumor size, tumor type, histologic grade and lymph node status, were investigated using multiple linear regression. Triple-negative tumor were more likely to have a large invasive size (p = 0.002), high histological grade (p < 0.001), lymph node involvement (p = 0.022) and strong ki-67 expression (p < 0.001). The highest mean SWV value were recorded in triple-negative tumors (7.36 m/s±1.83), followed by HER2+ tumors (6.65 m/s±2.26) and ER+ tumors (6.60 m/s±2.35) (p = 0.122). Triple-negative tumors were also associated with increased stiffness than ER+ tumors and HER2+ tumors (p = 0.016), as measured by qualitative VTI scores. Tumor size was independently associated with mean SWV value on adjusted regression (p < 0.001). Triple-negative breast cancer is associated with high stiffness scores and SWV in ARFI. The latter may be considered a useful complementary tool in evaluation of triple-negative breast cancer.

  9. Defining Genomic Changes in Triple Negative Breast Cancer in Women of African Descent

    DTIC Science & Technology

    2013-07-01

    Triple negative breast cancer , Ethnic disparities, Breast cancer amongst African - Americans and Africans , Gene expression... Americans . Adjacent Normal AA Native African TN BC Tissue Figure 1. Gene Expression Pattern of Native African Triple Negative Breast Cancer ...and African - American Adjacent Normal Breast Tissue Genes PI: Pegram & Baumbach

  10. Risk factors for eye bank preparation failure of Descemet membrane endothelial keratoplasty tissue.

    PubMed

    Vianna, Lucas M M; Stoeger, Christopher G; Galloway, Joshua D; Terry, Mark; Cope, Leslie; Belfort, Rubens; Jun, Albert S

    2015-05-01

    To assess the results of a single eye bank preparing a high volume of Descemet membrane endothelial keratoplasty (DMEK) tissues using multiple technicians to provide an overview of the experience and to identify possible risk factors for DMEK preparation failure. Cross-sectional study. setting: Lions VisionGift and Wilmer Eye Institute at Johns Hopkins Hospital. All 563 corneal tissues processed by technicians at Lions VisionGift for DMEK between October 2011 and May 2014 inclusive. Tissues were divided into 2 groups: DMEK preparation success and DMEK preparation failure. We compared donor characteristics, including past medical history. The overall tissue preparation failure rate was 5.2%. Univariate analysis showed diabetes mellitus (P = .000028) and its duration (P = .023), hypertension (P = .021), and hyperlipidemia or obesity (P = .0004) were more common in the failure group. Multivariate analysis showed diabetes mellitus (P = .0001) and hyperlipidemia or obesity (P = .0142) were more common in the failure group. Elimination of tissues from donors either with diabetes or with hyperlipidemia or obesity reduced the failure rate from 5.2% to 2.2%. Trends toward lower failure rates occurring with increased technician experience also were found. Our work showed that tissues from donors with diabetes mellitus (especially with longer disease duration) and hyperlipidemia or obesity were associated with higher failure rates in DMEK preparation. Elimination of tissues from donors either with diabetes mellitus or with hyperlipidemia or obesity reduced the failure rate. In addition, our data may provide useful initial guidelines and benchmark values for eye banks seeking to establish and maintain DMEK programs. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Implantation of a customized toric intraocular lens for correction of post-keratoplasty astigmatism

    PubMed Central

    Srinivasan, S; Ting, D S J; Lyall, D A M

    2013-01-01

    Purpose To report visual and refractive outcomes, and endothelial cell loss following primary and secondary ‘piggyback' toric intraocular lens (IOL) implantation in patients with high post-penetrating keratoplasty (PK) astigmatism. Methods Prospective case series. Nine eyes of nine patients with post-PK astigmatism were consecutively recruited for implantation of a customized toric IOL. Six underwent simultaneous phacoemulsification (PE) and three pseudophakic eyes had a secondary ‘piggyback' toric IOL implanted in the ciliary sulcus. Mean follow-up time was 17.2±7.7 months. Pre- and post-operative uncorrected (UDVA) and best-corrected (BDVA) distance visual acuities and refractive errors were collected for comparison. Cartesian astigmatic vectors were calculated to identify a change in the magnitude of astigmatism pre- compared to postoperatively. Pre- and post-operative endothelial cell counts were also collected for analysis. Results UDVA (logMAR) improved from 1.13±0.51 preoperatively to 0.48±0.24 postoperatively (P-value=0.003). There was no significant change in BDVA (P-value=0.905) from 0.31±0.27 to 0.26±0.19. Corneal astigmatism preoperatively was 6.57±4.40 diopters (D). Post-operative refractive cylinder was 0.83±1.09 D compared to 3.89±4.01 D preoperatively (P=0.039). Analysis of astigmatic Cartesian x and y coordinates found a significant reduction postoperatively compared to preoperatively (P=0.005 and P=0.002), respectively. Mean endothelial cell loss was 9.9%. Conclusion: Implantation of a customized primary or secondary ‘piggyback' toric IOL serves as an effective modality in treating patients with high post-PK astigmatism. PMID:23348728

  12. Hydroxyproline Ring Pucker Causes Frustration of Helix Parameters in the Collagen Triple Helix

    NASA Astrophysics Data System (ADS)

    Ying Chow, W.; Bihan, Dominique; Forman, Chris J.; Slatter, David A.; Reid, David G.; Wales, David J.; Farndale, Richard W.; Duer, Melinda J.

    2015-07-01

    Collagens, the most abundant proteins in mammals, are defined by their triple-helical structures and distinctive Gly-Xaa-Yaa repeating sequence, where Xaa is often proline and Yaa, hydroxyproline (Hyp/O). It is known that hydroxyproline in the Yaa position stabilises the triple helix, and that lack of proline hydroxylation in vivo leads to dysfunctional collagen extracellular matrix assembly, due to a range of factors such as a change in hydration properties. In addition, we note that in model peptides, when Yaa is unmodified proline, the Xaa proline has a strong propensity to adopt an endo ring conformation, whilst when Yaa is hydroxyproline, the Xaa proline adopts a range of endo and exo conformations. Here we use a combination of solid-state NMR spectroscopy and potential energy landscape modelling of synthetic triple-helical collagen peptides to understand this effect. We show that hydroxylation of the Yaa proline causes the Xaa proline ring conformation to become metastable, which in turn confers flexibility on the triple helix.

  13. Hydroxyproline Ring Pucker Causes Frustration of Helix Parameters in the Collagen Triple Helix

    PubMed Central

    Ying Chow, W.; Bihan, Dominique; Forman, Chris J.; Slatter, David A.; Reid, David G.; Wales, David J.; Farndale, Richard W.; Duer, Melinda J.

    2015-01-01

    Collagens, the most abundant proteins in mammals, are defined by their triple-helical structures and distinctive Gly-Xaa-Yaa repeating sequence, where Xaa is often proline and Yaa, hydroxyproline (Hyp/O). It is known that hydroxyproline in the Yaa position stabilises the triple helix, and that lack of proline hydroxylation in vivo leads to dysfunctional collagen extracellular matrix assembly, due to a range of factors such as a change in hydration properties. In addition, we note that in model peptides, when Yaa is unmodified proline, the Xaa proline has a strong propensity to adopt an endo ring conformation, whilst when Yaa is hydroxyproline, the Xaa proline adopts a range of endo and exo conformations. Here we use a combination of solid-state NMR spectroscopy and potential energy landscape modelling of synthetic triple-helical collagen peptides to understand this effect. We show that hydroxylation of the Yaa proline causes the Xaa proline ring conformation to become metastable, which in turn confers flexibility on the triple helix. PMID:26220399

  14. Facile scission of isonitrile carbon–nitrogen triple bond using a diborane(4) reagent

    PubMed Central

    Asakawa, Hiroki; Lee, Ka-Ho; Lin, Zhenyang; Yamashita, Makoto

    2014-01-01

    Transition metal reagents and catalysts are generally effective to cleave all three bonds (one σ and two π) in a triple bond despite its high bonding energy. Recently, chemistry of single-bond cleavage by using main-group element compounds is rapidly being developed in the absence of transition metals. However, the cleavage of a triple bond using non-transition-metal compounds is less explored. Here we report that an unsymmetrical diborane(4) compound could react with carbon monoxide and tert-butyl isonitrile at room temperature. In the latter case, the carbon–nitrogen triple bond was completely cleaved in the absence of transition metal as confirmed by X-ray crystallographic analysis, 13C NMR spectroscopy with 13C labelling and DFT calculations. The DFT calculations also revealed the detailed reaction mechanism and indicated that the key for the carbon–nitrogen triple-bond cleavage could be attributed to the presence of nucleophilic nitrogen atom in one of the intermediates. PMID:24967910

  15. A Biatrial Myxoma with Triple Ripples.

    PubMed

    Barik, Ramachandra

    2018-01-01

    Cardiac myxoma is a benign tumor, but it is known for its space-occupying effect at the site of origin and frequent systemic embolization. This case report highlights a biatrial myxoma of interatrial septum who presented with significant tricuspid valve regurgitation, atrial fibrillation, and cardioembolic stroke of the left parietal lobe, i.e., a biatrial myxoma with triple ripples.

  16. Does test-enhanced learning transfer for triple associates?

    PubMed

    Pan, Steven C; Wong, Carol M; Potter, Zachary E; Mejia, Jonathan; Rickard, Timothy C

    2016-01-01

    Test-enhanced learning and transfer for triple-associate word stimuli was assessed in three experiments. In each experiment, training and final-test trials involved the presentation of two words per triple associate (triplet), with the third word having to be retrieved. In agreement with the prior literature on different stimuli, training through testing with feedback yielded markedly better final-test performance than did restudy. However, in contrast to the positive transfer reported for paired associate stimuli, minimal or no positive transfer was observed, relative to a restudy control, from a trained cue combination (e.g., A, B, ?) to other cue combinations from the same triplet that required a different response (e.g., B, C, ?). That result also held when two unique cue combinations per triplet were tested during training, and for triplets with low and high average associative strengths. Supplementary analyses provided insight into the overall transfer effect: An incorrect response during training appears to yield positive transfer relative to restudy, whereas a correct response appears to yield no, or even negative, transfer. Cross-experiment analyses indicated that test-enhanced learning is not diminished when two or three cue combinations are presented during training. Thus, even though learning through testing is highly specific, testing on all possible stimulus-response combinations remains the most efficient strategy for the learning of triple associates.

  17. GATA3 expression in triple-negative breast cancers.

    PubMed

    Byrne, David J; Deb, Siddhartha; Takano, Elena A; Fox, Stephen B

    2017-07-01

    GATA-binding protein 3 (GATA3) is a well-studied transcription factor found to be essential in the development of luminal breast epithelium and has been identified in a variety of tumour types, including breast and urothelial carcinomas, making it a useful immunohistochemistry marker in the diagnosis of both primary and metastatic disease. We investigated GATA3 protein expression in a 106 primary triple-negative breast carcinomas (100 basal-like, six non-basal-like) using Cell Marque mouse monoclonal anti-GATA3 (L50-823). Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used to quantify mRNA expression in 22 triple-negative breast cancers (TNBCs) (20 primary and two cell lines), four luminal (three primary and one cell line) and five human epidermal growth factor receptor 2 (HER2) (four primary and one cell line) amplified tumours. In 98 TNBCs where IHC was assessable, 47 (48%) had a 1+ or greater staining with 20 (21%) having high GATA3 expression when using a weighted scoring. Our study has demonstrated that GATA3 expression is common in primary triple-negative breast carcinomas. It also suggests that although GATA3 is an oestrogen receptor (ER) regulated gene, it still proves useful in differentiating between primary and metastatic tumours in patients with a history of breast cancer regardless of its molecular subtype. © 2017 John Wiley & Sons Ltd.

  18. TGMI: an efficient algorithm for identifying pathway regulators through evaluation of triple-gene mutual interaction

    PubMed Central

    Gunasekara, Chathura; Zhang, Kui; Deng, Wenping; Brown, Laura

    2018-01-01

    Abstract Despite their important roles, the regulators for most metabolic pathways and biological processes remain elusive. Presently, the methods for identifying metabolic pathway and biological process regulators are intensively sought after. We developed a novel algorithm called triple-gene mutual interaction (TGMI) for identifying these regulators using high-throughput gene expression data. It first calculated the regulatory interactions among triple gene blocks (two pathway genes and one transcription factor (TF)), using conditional mutual information, and then identifies significantly interacted triple genes using a newly identified novel mutual interaction measure (MIM), which was substantiated to reflect strengths of regulatory interactions within each triple gene block. The TGMI calculated the MIM for each triple gene block and then examined its statistical significance using bootstrap. Finally, the frequencies of all TFs present in all significantly interacted triple gene blocks were calculated and ranked. We showed that the TFs with higher frequencies were usually genuine pathway regulators upon evaluating multiple pathways in plants, animals and yeast. Comparison of TGMI with several other algorithms demonstrated its higher accuracy. Therefore, TGMI will be a valuable tool that can help biologists to identify regulators of metabolic pathways and biological processes from the exploded high-throughput gene expression data in public repositories. PMID:29579312

  19. Revised Reynolds Stress and Triple Product Models

    NASA Technical Reports Server (NTRS)

    Olsen, Michael E.; Lillard, Randolph P.

    2017-01-01

    Revised versions of Lag methodology Reynolds-stress and triple product models are applied to accepted test cases to assess the improvement, or lack thereof, in the prediction capability of the models. The Bachalo-Johnson bump flow is shown as an example for this abstract submission.

  20. Micro-photoluminescence of GaAs/AlGaAs triple concentric quantum rings.

    PubMed

    Abbarchi, Marco; Cavigli, Lucia; Somaschini, Claudio; Bietti, Sergio; Gurioli, Massimo; Vinattieri, Anna; Sanguinetti, Stefano

    2011-10-31

    A systematic optical study, including micro, ensemble and time resolved photoluminescence of GaAs/AlGaAs triple concentric quantum rings, self-assembled via droplet epitaxy, is presented. Clear emission from localized states belonging to the ring structures is reported. The triple rings show a fast decay dynamics, around 40 ps, which is expected to be useful for ultrafast optical switching applications.

  1. Triple dose of gadolinium-DTPA and delayed MRI in patients with benign multiple sclerosis.

    PubMed Central

    Filippi, M; Capra, R; Campi, A; Colombo, B; Prandini, F; Marcianò, N; Gasparotti, R; Comi, G

    1996-01-01

    OBJECTIVES--To evaluate whether a triple dose of gadolinium-DTPA (Gd-DTPA) or delayed MRI increase the number, size, and conspicuousness of enhancing lesions in patients with benign multiple sclerosis. METHODS--T1 weighted brain MRI was carried out on 20 patients with benign multiple sclerosis (expanded disability status scale < 3 with a disease duration > 10 years) in two sessions. In the first session, one scan was obtained before and two scans five to seven minutes and 20-30 minutes after the injection of 0.1 mmol/kg Gd-DTPA (standard dose). In the second session, six to 24 hours later, the same procedure was repeated with 0.3 mmol/kg Gd-DTPA (triple dose). RESULTS--Nine enhancing lesions were found in seven patients (35%) using the standard dose of Gd-DTPA. The numbers of enhancing lesions increased to 13 (P = 0.03) and the number of patients with such lesions to eight (40%) on the delayed standard dose scans. On the early triple dose scans, we found 19 enhancing lesions in 10 patients (50%). The number of enhancing lesions was significantly higher (P = 0.01) than that obtained with the early standard dose. The number of enhancing lesions was 18 and the number of "active" patients 11 (55%) on the delayed triple dose scans. The enhancing areas increased progressively from the early standard dose scans to the delayed triple dose scans. The contrast ratios of the lesions detected in early standard dose scans was lower than those of lesions present in the early (P = 0.01) and delayed (P = 0.04) triple dose scans. CONCLUSIONS--More enhancing lesions were detected in patients with benign multiple sclerosis with both delay of MRI and the use of triple dose of Gd-DTPA suggesting that the amount of inflammation in the lesions of such patients is mild and heterogeneous. Images PMID:8778257

  2. Transition from slab to slabless: Results from the 1993 Mendocino triple junction seismic experiment

    USGS Publications Warehouse

    Beaudoin, B.C.; Godfrey, N.J.; Klemperer, S.L.; Lendl, C.; Trehu, A.M.; Henstock, T.J.; Levander, A.; Holl, J.E.; Meltzer, A.S.; Luetgert, J.H.; Mooney, W.D.

    1996-01-01

    Three seismic refraction-reflection profiles, part of the Mendocino triple junction seismic experiment, allow us to compare and contrast crust and upper mantle of the North American margin before and after it is modified by passage of the Mendocino triple junction. Upper crustal velocity models reveal an asymmetric Great Valley basin overlying Sierran or ophiolitic rocks at the latitude of Fort Bragg, California, and overlying Sierran or Klamath rocks near Redding, California. In addition, the upper crustal velocity structure indicates that Franciscan rocks underlie the Klamath terrane east of Eureka, California. The Franciscan complex is, on average, laterally homogeneous and is thickest in the triple junction region. North of the triple junction, the Gorda slab can be traced 150 km inboard from the Cascadia subduction zone. South of the triple junction, strong precritical reflections indicate partial melt and/or metamorphic fluids at the base of the crust or in the upper mantle. Breaks in these reflections are correlated with the Maacama and Bartlett Springs faults, suggesting that these faults extend at least to the mantle. We interpret our data to indicate tectonic thickening of the Franciscan complex in response to passage of the Mendocino triple junction and an associated thinning of these rocks south of the triple junction due to assimilation into melt triggered by upwelling asthenosphere. The region of thickened Franciscan complex overlies a zone of increased scattering, intrinsic attenuation, or both, resulting from mechanical mixing of lithologies and/or partial melt beneath the onshore projection of the Mendocino fracture zone. Our data reveal that we have crossed the southern edge of the Gorda slab and that this edge and/or the overlying North American crust may have fragmented because of the change in stress presented by the edge.

  3. Distributed deformation ahead of the Cocos-Nazca Rift at the Galapagos triple junction

    NASA Astrophysics Data System (ADS)

    Smith, Deborah K.; Schouten, Hans; Zhu, Wen-lu; Montési, Laurent G. J.; Cann, Johnson R.

    2011-11-01

    The Galapagos triple junction is not a simple ridge-ridge-ridge (RRR) triple junction. The Cocos-Nazca Rift (C-N Rift) tip does not meet the East Pacific Rise (EPR). Instead, two secondary rifts form the link: Incipient Rift at 2°40‧N and Dietz Deep volcanic ridge, the southern boundary of the Galapagos microplate (GMP), at 1°10‧N. Recently collected bathymetry data are used to investigate the regional tectonics prior to the establishment of the GMP (∼1.5 Ma). South of C-N Rift a band of northeast-trending cracks cuts EPR-generated abyssal hills. It is a mirror image of a band of cracks previously identified north of C-N Rift on the same age crust. In both areas, the western ends of the cracks terminate against intact abyssal hills suggesting that each crack initiated at the EPR spreading center and cut eastward into pre-existing topography. Each crack formed a short-lived triple junction until it was abandoned and a new crack and triple junction initiated nearby. Between 2.5 and 1.5 Ma, the pattern of cracking is remarkably symmetric about C-N Rift providing support for a crack interaction model in which crack initiation at the EPR axis is controlled by stresses associated with the tip of the westward-propagating C-N Rift. The model also shows that offsets of the EPR axis may explain times when cracking is not symmetric. South of C-N Rift, cracks are observed on seafloor as old as 10.5 Ma suggesting that this triple junction has not been a simple RRR triple junction during that time.

  4. From Triple to Quadruple Aim: Care of the Patient Requires Care of the Provider

    PubMed Central

    Bodenheimer, Thomas; Sinsky, Christine

    2014-01-01

    The Triple Aim—enhancing patient experience, improving population health, and reducing costs—is widely accepted as a compass to optimize health system performance. Yet physicians and other members of the health care workforce report widespread burnout and dissatisfaction. Burnout is associated with lower patient satisfaction, reduced health outcomes, and it may increase costs. Burnout thus imperils the Triple Aim. This article recommends that the Triple Aim be expanded to a Quadruple Aim, adding the goal of improving the work life of health care providers, including clinicians and staff. PMID:25384822

  5. Defining Genomic Changes in Triple-Negative Breast Cancer in Women of African Descent

    DTIC Science & Technology

    2012-06-01

    Triple negative breast cancer • Ethnic disparities • Breast cancer amongst African Americans and Africans • Gene expression profiling • Array... negative cases seen in both African and African - American breast cancer cases. Gene Expression Array Studies The 31 triple negative Kijabe... African - American Adjacent Normal Breast Tissue PI: Pegram &

  6. Secondary angle closure caused by air migrating behind the pupil in descemet stripping endothelial keratoplasty.

    PubMed

    Lee, Jung S; Desai, Neel R; Schmidt, Gregory W; Jun, Albert S; Schein, Oliver D; Stark, Walter J; Eghrari, Allen O; Gottsch, John D

    2009-07-01

    To report secondary angle closure caused by air migrating behind the pupil in the context of intraocular pressure (IOP) elevation in the early postoperative period after Descemet stripping endothelial keratoplasty (DSEK). A retrospective case series was conducted on 100 consecutive DSEK cases from 90 patients undergoing DSEK because of corneal disease from Fuchs corneal dystrophy, pseudophakic bullous keratopathy, aphakic bullous keratopathy, and iridocorneal endothelial syndrome. Preoperative and postoperative slit-lamp examinations and IOP measurements were ascertained for all 100 eyes. Main outcome measures included preoperative and postoperative IOP. Thirteen of 100 eyes developed an IOP rise of greater than 30 mm Hg on the first postoperative day. Six of these 13 patients developed angle closure from air migrating posterior to the iris and causing iridocorneal adhesions. One of these 13 patients developed pupillary block from air anterior to iris. Six of 13 patients developed increased IOP without pupillary block or iridocorneal adhesions and had a history of preexisting primary or secondary glaucoma. A secondary angle closure associated with DSEK is reported with air migrating behind the iris, resulting in extensive iridocorneal adhesions. An acute increase in IOP after DSEK can also be induced by air anterior to the iris causing pupillary block. IOP spikes are much more common in the first few postoperative days after DSEK. Medical treatment can occasionally resolve air posterior to the iris, but if iridocorneal adhesions are extensive and persistent, air removal and angle reformation may be necessary.

  7. Revealing Secrets of Triple Asteroid Systems with SPHERE

    NASA Astrophysics Data System (ADS)

    Yang, Bin; Wahhaj, Zahed; Beauvalet, Laurene; Marchis, Franck; Dumas, Christophe; Marsset, Michaël

    2015-11-01

    A multiple-asteroid system provides otherwise unattainable information about the intrinsic properties of the system itself as well as its formation and evolution. Comparative spectroscopy and imaging of two large multiple main-belt asteroids: (93) Minerva and (130) Elektra were performed using the newly commissioned Spectro-Polarimetric High-contrast Exoplanet Research instrument (SPHERE) on ESO's 8.2-m VLT. A new moon (S/2014 (130) 1), of the known binary asteroid (130) Elektra, was discovered based on the SPHERE observations, making (130) Elektra the sixth triple system detected in the asteroid belt. We will present the component-resolved near infrared spectra, from 0.9 to 1.6 micron, of the Minerva and the Elektra triple systems. We will also present the orbital solution and the dynamical simulations on the two moons of (130) Elektra.

  8. The Contribution of Interchain Salt Bridges to Triple-Helical Stability in Collagen

    PubMed Central

    Gurry, Thomas; Nerenberg, Paul S.; Stultz, Collin M.

    2010-01-01

    Abstract Studies on collagen and collagen-like peptides suggest that triple-helical stability can vary along the amino acid chain. In this regard, it has been shown that lysine residues in the Y position and acidic residues in the X′ position of (GPO)3GXYGX′Y′(GPO)3 peptides lead to triple-helical structures with melting temperatures similar to (GPO)8 (where O is hydroxyproline), which is generally regarded as the most stable collagen-like sequence of this length. This enhanced stability has been attributed to the formation of salt bridges between adjacent collagen chains. In this study, we explore the relationship between interchain salt bridge formation and triple-helical stability using detailed molecular simulations. Although our results confirm that salt bridges promote triple-helical stability, we find that not all salt bridges are created equal. In particular, lysine-glutamate salt bridges are most stabilizing when formed between residues in the middle strand (B) and the trailing strand (C), whereas lysine-aspartate salt bridges are most stabilizing when formed between residues in the leading (A) and middle (B) strand—the latter observation being consistent with recent NMR data on a heterotrimeric model peptide. Overall, we believe these data clarify the role of salt bridges in modulating triple-helical stability and can be used to guide the design of collagen-like peptides that have specific interchain interactions. PMID:20513408

  9. Resolving an anomaly in electron temperature measurement using double and triple Langmuir probes

    NASA Astrophysics Data System (ADS)

    Ghosh, Soumen; Barada, K. K.; Chattopadhyay, P. K.; Ghosh, J.; Bora, D.

    2015-02-01

    Langmuir probes with variants such as single, double and triple probes remain the most common method of electron temperature measurement in low-temperature laboratory plasmas. However, proper estimation of electron temperature mainly using triple probe configuration requires the proper choice of compensation factor (W). Determination of the compensating factor is not very straightforward as it depends heavily on plasma floating potential (Vf), electron temperature (Te), the type of gas used for plasma production and the bias voltage applied to probe pins, especially in cases where there are substantial variations in floating potential. In this paper we highlight the anomaly in electron temperature measurement using double and triple Langmuir probe techniques as well as the proper determination of the compensation factor (W) to overcome this anomaly. Experiments are carried out with helicon antenna producing inductive radiofrequency plasmas, where significant variation of floating potential along the axis enables a detailed study of deviations introduced in Te measurements using triple probes compared to double and single probes. It is observed that the bias voltage between the probe pins of the triple probes plays an important role in the accurate determination of the compensating factor (W) and should be in the range (5Vd2 < Vd3 < 10Vd2), where Vd2 and Vd3 are the voltage between floating probe pins 2 and 1 and the bias voltage, respectively.

  10. The Triple Response Assay and Its Use to Characterize Ethylene Mutants in Arabidopsis.

    PubMed

    Merchante, Catharina; Stepanova, Anna N

    2017-01-01

    Exposure of plants to ethylene results in drastic morphological changes. Seedlings germinated in the dark in the presence of saturating concentrations of ethylene display a characteristic phenotype known as the triple response. This phenotype is robust and easy to score. In Arabidopsis the triple response is usually evaluated at 3 days post germination in seedlings grown in the dark in rich media supplemented with 10 μM of the ethylene precursor ACC in air or in unsupplemented media in the presence of 10 ppm ethylene. The triple response in Arabidopsis consists of shortening and thickening of hypocotyls and roots and exaggeration of the curvature of apical hooks. The search for Arabidopsis mutants that fail to show this phenotype in ethylene or, vice versa, display the triple response in the absence of exogenously supplied hormone has allowed the identification of the key components of the ethylene biosynthesis and signaling pathways. Herein, we describe a simple protocol for assaying the triple response in Arabidopsis. The method can also be employed in many other dicot species, with minor modifications to account for species-specific differences in germination. We also compiled a comprehensive table of ethylene-related mutants of Arabidopsis, including many lines with auxin-related defects, as wild-type levels of auxin biosynthesis, transport, signaling, and response are necessary for the normal response of plants to ethylene.

  11. BioBenchmark Toyama 2012: an evaluation of the performance of triple stores on biological data

    PubMed Central

    2014-01-01

    Background Biological databases vary enormously in size and data complexity, from small databases that contain a few million Resource Description Framework (RDF) triples to large databases that contain billions of triples. In this paper, we evaluate whether RDF native stores can be used to meet the needs of a biological database provider. Prior evaluations have used synthetic data with a limited database size. For example, the largest BSBM benchmark uses 1 billion synthetic e-commerce knowledge RDF triples on a single node. However, real world biological data differs from the simple synthetic data much. It is difficult to determine whether the synthetic e-commerce data is efficient enough to represent biological databases. Therefore, for this evaluation, we used five real data sets from biological databases. Results We evaluated five triple stores, 4store, Bigdata, Mulgara, Virtuoso, and OWLIM-SE, with five biological data sets, Cell Cycle Ontology, Allie, PDBj, UniProt, and DDBJ, ranging in size from approximately 10 million to 8 billion triples. For each database, we loaded all the data into our single node and prepared the database for use in a classical data warehouse scenario. Then, we ran a series of SPARQL queries against each endpoint and recorded the execution time and the accuracy of the query response. Conclusions Our paper shows that with appropriate configuration Virtuoso and OWLIM-SE can satisfy the basic requirements to load and query biological data less than 8 billion or so on a single node, for the simultaneous access of 64 clients. OWLIM-SE performs best for databases with approximately 11 million triples; For data sets that contain 94 million and 590 million triples, OWLIM-SE and Virtuoso perform best. They do not show overwhelming advantage over each other; For data over 4 billion Virtuoso works best. 4store performs well on small data sets with limited features when the number of triples is less than 100 million, and our test shows its

  12. BioBenchmark Toyama 2012: an evaluation of the performance of triple stores on biological data.

    PubMed

    Wu, Hongyan; Fujiwara, Toyofumi; Yamamoto, Yasunori; Bolleman, Jerven; Yamaguchi, Atsuko

    2014-01-01

    Biological databases vary enormously in size and data complexity, from small databases that contain a few million Resource Description Framework (RDF) triples to large databases that contain billions of triples. In this paper, we evaluate whether RDF native stores can be used to meet the needs of a biological database provider. Prior evaluations have used synthetic data with a limited database size. For example, the largest BSBM benchmark uses 1 billion synthetic e-commerce knowledge RDF triples on a single node. However, real world biological data differs from the simple synthetic data much. It is difficult to determine whether the synthetic e-commerce data is efficient enough to represent biological databases. Therefore, for this evaluation, we used five real data sets from biological databases. We evaluated five triple stores, 4store, Bigdata, Mulgara, Virtuoso, and OWLIM-SE, with five biological data sets, Cell Cycle Ontology, Allie, PDBj, UniProt, and DDBJ, ranging in size from approximately 10 million to 8 billion triples. For each database, we loaded all the data into our single node and prepared the database for use in a classical data warehouse scenario. Then, we ran a series of SPARQL queries against each endpoint and recorded the execution time and the accuracy of the query response. Our paper shows that with appropriate configuration Virtuoso and OWLIM-SE can satisfy the basic requirements to load and query biological data less than 8 billion or so on a single node, for the simultaneous access of 64 clients. OWLIM-SE performs best for databases with approximately 11 million triples; For data sets that contain 94 million and 590 million triples, OWLIM-SE and Virtuoso perform best. They do not show overwhelming advantage over each other; For data over 4 billion Virtuoso works best. 4store performs well on small data sets with limited features when the number of triples is less than 100 million, and our test shows its scalability is poor; Bigdata

  13. Robust Modeling of Stellar Triples in PHOEBE

    NASA Astrophysics Data System (ADS)

    Conroy, Kyle E.; Prsa, Andrej; Horvat, Martin; Stassun, Keivan G.

    2017-01-01

    The number of known mutually-eclipsing stellar triple and multiple systems has increased greatly during the Kepler era. These systems provide significant opportunities to both determine fundamental stellar parameters of benchmark systems to unprecedented precision as well as to study the dynamical interaction and formation mechanisms of stellar and planetary systems. Modeling these systems to their full potential, however, has not been feasible until recently. Most existing available codes are restricted to the two-body binary case and those that do provide N-body support for more components make sacrifices in precision by assuming no stellar surface distortion. We have completely redesigned and rewritten the PHOEBE binary modeling code to incorporate support for triple and higher-order systems while also robustly modeling data with Kepler precision. Here we present our approach, demonstrate several test cases based on real data, and discuss the current status of PHOEBE's support for modeling these types of systems. PHOEBE is funded in part by NSF grant #1517474.

  14. Triple grouping and period-three oscillations in minority-game dynamics.

    PubMed

    Dong, Jia-Qi; Huang, Zi-Gang; Huang, Liang; Lai, Ying-Cheng

    2014-12-01

    Dynamical systems based on the minority game (MG) have been a paradigm for gaining significant insights into a variety of social and biological behaviors. Recently, a grouping phenomenon has been unveiled in MG systems of multiple resources (strategies) in which the strategies spontaneously break into an even number of groups, each exhibiting an identical oscillation pattern in the attendance of game players. Here we report our finding of spontaneous breakup of resources into three groups, each exhibiting period-three oscillations. An analysis is developed to understand the emergence of the striking phenomenon of triple grouping and period-three oscillations. In the presence of random disturbances, the triple-group/period-three state becomes transient, and we obtain explicit formula for the average transient lifetime using two methods of approximation. Our finding indicates that, period-three oscillation, regarded as one of the most fundamental behaviors in smooth nonlinear dynamical systems, can also occur in much more complex, evolutionary-game dynamical systems. Our result also provides a plausible insight for the occurrence of triple grouping observed, for example, in the U.S. housing market.

  15. A Biatrial Myxoma with Triple Ripples

    PubMed Central

    Barik, Ramachandra

    2018-01-01

    Cardiac myxoma is a benign tumor, but it is known for its space-occupying effect at the site of origin and frequent systemic embolization. This case report highlights a biatrial myxoma of interatrial septum who presented with significant tricuspid valve regurgitation, atrial fibrillation, and cardioembolic stroke of the left parietal lobe, i.e., a biatrial myxoma with triple ripples. PMID:29629263

  16. Micro-photoluminescence of GaAs/AlGaAs triple concentric quantum rings

    PubMed Central

    2011-01-01

    A systematic optical study, including micro, ensemble and time resolved photoluminescence of GaAs/AlGaAs triple concentric quantum rings, self-assembled via droplet epitaxy, is presented. Clear emission from localized states belonging to the ring structures is reported. The triple rings show a fast decay dynamics, around 40 ps, which is expected to be useful for ultrafast optical switching applications. PMID:22039893

  17. Lifestyle Triple P: a parenting intervention for childhood obesity

    PubMed Central

    2012-01-01

    Background Reversing the obesity epidemic requires the development and evaluation of childhood obesity intervention programs. Lifestyle Triple P is a parent-focused group program that addresses three topics: nutrition, physical activity, and positive parenting. Australian research has established the efficacy of Lifestyle Triple P, which aims to prevent excessive weight gain in overweight and obese children. The aim of the current randomized controlled trial is to assess the effectiveness of the Lifestyle Triple P intervention when applied to Dutch parents of overweight and obese children aged 4–8 years. This effectiveness study is called GO4fit. Methods/Design Parents of overweight and obese children are being randomized to either the intervention or the control group. Those assigned to the intervention condition receive the 14-week Lifestyle Triple P intervention, in which they learn a range of nutritional, physical activity and positive parenting strategies. Parents in the control group receive two brochures, web-based tailored advice, and suggestions for exercises to increase active playing at home. Measurements are taken at baseline, directly after the intervention, and at one year follow-up. Primary outcome measure is the children’s body composition, operationalized as BMI z-score, waist circumference, and fat mass (biceps and triceps skinfolds). Secondary outcome measures are children’s dietary behavior and physical activity level, parenting practices, parental feeding style, parenting style, parental self-efficacy, and body composition of family members (parents and siblings). Discussion Our intervention is characterized by a focus on changing general parenting styles, in addition to focusing on changing specific parenting practices, as obesity interventions typically do. Strengths of the current study are the randomized design, the long-term follow-up, and the broad range of both self-reported and objectively measured outcomes. Trial Registration

  18. Lifestyle Triple P: a parenting intervention for childhood obesity.

    PubMed

    Gerards, Sanne M P L; Dagnelie, Pieter C; Jansen, Maria W J; van der Goot, Lidy O H M; de Vries, Nanne K; Sanders, Matthew R; Kremers, Stef P J

    2012-04-03

    Reversing the obesity epidemic requires the development and evaluation of childhood obesity intervention programs. Lifestyle Triple P is a parent-focused group program that addresses three topics: nutrition, physical activity, and positive parenting. Australian research has established the efficacy of Lifestyle Triple P, which aims to prevent excessive weight gain in overweight and obese children. The aim of the current randomized controlled trial is to assess the effectiveness of the Lifestyle Triple P intervention when applied to Dutch parents of overweight and obese children aged 4-8 years. This effectiveness study is called GO4fit. Parents of overweight and obese children are being randomized to either the intervention or the control group. Those assigned to the intervention condition receive the 14-week Lifestyle Triple P intervention, in which they learn a range of nutritional, physical activity and positive parenting strategies. Parents in the control group receive two brochures, web-based tailored advice, and suggestions for exercises to increase active playing at home. Measurements are taken at baseline, directly after the intervention, and at one year follow-up. Primary outcome measure is the children's body composition, operationalized as BMI z-score, waist circumference, and fat mass (biceps and triceps skinfolds). Secondary outcome measures are children's dietary behavior and physical activity level, parenting practices, parental feeding style, parenting style, parental self-efficacy, and body composition of family members (parents and siblings). Our intervention is characterized by a focus on changing general parenting styles, in addition to focusing on changing specific parenting practices, as obesity interventions typically do. Strengths of the current study are the randomized design, the long-term follow-up, and the broad range of both self-reported and objectively measured outcomes. Current Controlled Trials NTR 2555 MEC AZM/UM: NL 31988

  19. Triple Science GCSEs: Curriculum Planning and Design. GCSEs in Biology, Chemistry and Physics

    ERIC Educational Resources Information Center

    Morris, Pam; Quill, John

    2007-01-01

    This publication will provide managers and others with practical advice on how to plan, develop and model the Triple Science requirement, taking into account all the critical factors that need to be considered. This guidance concentrates on curriculum planning and design, including the use of the new (2006) specifications to provide Triple Science…

  20. Analytic reconstruction algorithms for triple-source CT with horizontal data truncation.

    PubMed

    Chen, Ming; Yu, Hengyong

    2015-10-01

    This paper explores a triple-source imaging method with horizontal data truncation to enlarge the field of view (FOV) for big objects. The study is conducted by using theoretical analysis, mathematical deduction, and numerical simulations. The proposed algorithms are implemented in c + + and matlab. While the basic platform is constructed in matlab, the computationally intensive segments are coded in c + +, which are linked via a mex interface. A triple-source circular scanning configuration with horizontal data truncation is developed, where three pairs of x-ray sources and detectors are unevenly distributed on the same circle to cover the whole imaging object. For this triple-source configuration, a fan-beam filtered backprojection-type algorithm is derived for truncated full-scan projections without data rebinning. The algorithm is also extended for horizontally truncated half-scan projections and cone-beam projections in a Feldkamp-type framework. Using their method, the FOV is enlarged twofold to threefold to scan bigger objects with high speed and quality. The numerical simulation results confirm the correctness and effectiveness of the developed algorithms. The triple-source scanning configuration with horizontal data truncation cannot only keep most of the advantages of a traditional multisource system but also cover a larger FOV for big imaging objects. In addition, because the filtering is shift-invariant, the proposed algorithms are very fast and easily parallelized on graphic processing units.

  1. The hierarchical stability of the seven known large size ratio triple asteroids using the empirical stability parameters.

    PubMed

    Liu, Xiaodong; Baoyin, Hexi; Marchis, Franck

    In this study, the hierarchical stability of the seven known large size ratio triple asteroids is investigated. The effect of the solar gravity and primary's J 2 are considered. The force function is expanded in terms of mass ratios based on the Hill's approximation and the large size ratio property. The empirical stability parameters are used to examine the hierarchical stability of the triple asteroids. It is found that the all the known large size ratio triple asteroid systems are hierarchically stable. This study provides useful information for future evolutions of the triple asteroids.

  2. Triple Value System Dynamics Modeling to Help Stakeholders Engage with Food-Energy-Water Problems

    EPA Science Inventory

    Triple Value (3V) Community scoping projects and Triple Value Simulation (3VS) models help decision makers and stakeholders apply systems-analysis methodology to complex problems related to food production, water quality, and energy use. 3VS models are decision support tools that...

  3. FPA-FTIR Microspectroscopy for Monitoring Chemotherapy Efficacy in Triple-Negative Breast Cancer

    NASA Astrophysics Data System (ADS)

    Zawlik, Izabela; Kaznowska, Ewa; Cebulski, Jozef; Kolodziej, Magdalena; Depciuch, Joanna; Vongsvivut, Jitraporn; Cholewa, Marian

    2016-11-01

    Triple-negative breast cancer is the most aggressive breast cancer subtype with limited treatment options and a poor prognosis. Approximately 70% of triple-negative breast cancer patients fail to achieve a pathologic complete response (pCR) after chemotherapy due to the lack of targeted therapies for this subtype. We report here the development of a focal-plane-array Fourier transform infrared (FPA-FTIR) microspectroscopic technique combined with principal component analysis (PCA) for monitoring chemotherapy effects in triple-negative breast cancer patients. The PCA results obtained using the FPA-FTIR spectral data collected from the same patients before and after the chemotherapy revealed discriminatory features that were consistent with the pathologic and clinical responses to chemotherapy, indicating the potential of the technique as a monitoring tool for observing chemotherapy efficacy.

  4. Corneal transplantation trends in France from 2004 to 2015: A 12-year review.

    PubMed

    Bigan, Guillaume; Puyraveau, Marc; Saleh, Maher; Gain, Philippe; Martinache, Isabelle; Delbosc, Bernard; Gauthier, Anne-Sophie

    2018-04-01

    The aim of this study was to report the 12-year longitudinal trends in indication and corneal transplantation techniques in France from 2004 to 2015. The records of all corneal transplantations performed from 2004 to 2015 in France were retrospectively reviewed. The patient indications and types of transplant performed were analyzed. A total of 46,658 corneal transplantations were performed between 2004 and 2015, with 34,187 (73.3%) penetrating keratoplasty and 10,452 (22.4%) lamellar keratoplasty. The leading surgical indications were secondary endothelial failure (24.3%), keratoconus (18.8%), regraft (13.5%), and Fuchs endothelial corneal dystrophy (15.1%). Endothelial keratoplasty became the preferred technique for endothelial diseases and deep anterior lamellar keratoplasty the preferred technique for keratoconus, surpassing penetrating keratoplasty in 2013. Secondary endothelial failure is the top indication for performing a keratoplasty over the 12-year period. There was a shift from penetrating keratoplasty to endothelial keratoplasty performed for Fuchs endothelial corneal dystrophy and secondary endothelial failure, and to deep anterior lamellar keratoplasty, performed for keratoconus. This highlights an important shift in managing corneal diseases toward the application of selective and more conservative surgeries and changes in indications in corneal transplantation.

  5. Non-linearity of the collagen triple helix in solution and implications for collagen function.

    PubMed

    Walker, Kenneth T; Nan, Ruodan; Wright, David W; Gor, Jayesh; Bishop, Anthony C; Makhatadze, George I; Brodsky, Barbara; Perkins, Stephen J

    2017-06-16

    Collagen adopts a characteristic supercoiled triple helical conformation which requires a repeating (Xaa-Yaa-Gly) n sequence. Despite the abundance of collagen, a combined experimental and atomistic modelling approach has not so far quantitated the degree of flexibility seen experimentally in the solution structures of collagen triple helices. To address this question, we report an experimental study on the flexibility of varying lengths of collagen triple helical peptides, composed of six, eight, ten and twelve repeats of the most stable Pro-Hyp-Gly (POG) units. In addition, one unblocked peptide, (POG) 10unblocked , was compared with the blocked (POG) 10 as a control for the significance of end effects. Complementary analytical ultracentrifugation and synchrotron small angle X-ray scattering data showed that the conformations of the longer triple helical peptides were not well explained by a linear structure derived from crystallography. To interpret these data, molecular dynamics simulations were used to generate 50 000 physically realistic collagen structures for each of the helices. These structures were fitted against their respective scattering data to reveal the best fitting structures from this large ensemble of possible helix structures. This curve fitting confirmed a small degree of non-linearity to exist in these best fit triple helices, with the degree of bending approximated as 4-17° from linearity. Our results open the way for further studies of other collagen triple helices with different sequences and stabilities in order to clarify the role of molecular rigidity and flexibility in collagen extracellular and immune function and disease. © 2017 The Author(s).

  6. Preparation and characterization of triple shape memory composite foams.

    PubMed

    Nejad, Hossein Birjandi; Baker, Richard M; Mather, Patrick T

    2014-10-28

    Foams prepared from shape memory polymers (SMPs) offer the potential for low density materials that can be triggered to deploy with a large volume change, unlike their solid counterparts that do so at near-constant volume. While examples of shape memory foams have been reported in the past, they have been limited to dual SMPs: those polymers featuring one switching transition between an arbitrarily programmed shape and a single permanent shape established by constituent crosslinks. Meanwhile, advances by SMP researchers have led to several approaches toward triple- or multi-shape polymers that feature more than one switching phase and thus a multitude of temporary shapes allowing for a complex sequence of shape deployments. Here, we report the design, preparation, and characterization of a triple shape memory polymeric foam that is open cell in nature and features a two phase, crosslinked SMP with a glass transition temperature of one phase at a temperature lower than a melting transition of the second phase. The soft materials were observed to feature high fidelity, repeatable triple shape behavior, characterized in compression and demonstrated for complex deployment by fixing a combination of foam compression and bending. We further explored the wettability of the foams, revealing composition-dependent behavior favorable for future work in biomedical investigations.

  7. Accurate Acoustic Thermometry I: The Triple Point of Gallium

    NASA Astrophysics Data System (ADS)

    Moldover, M. R.; Trusler, J. P. M.

    1988-01-01

    The speed of sound in argon has been accurately measured in the pressure range 25-380 kPa at the temperature of the triple point of gallium (Tg) and at 340 kPa at the temperature of the triple point of water (Tt). The results are combined with previously published thermodynamic and transport property data to obtain Tg = (302.9169 +/- 0.0005) K on the thermodynamic scale. Among recent determinations of T68 (the temperature on IPTS-68) at the gallium triple point, those with the smallest measurement uncertainty fall in the range 302.923 71 to 302.923 98 K. We conclude that T-T68 = (-6.9 +/- 0.5) mK near 303 K, in agreement with results obtained from other primary thermometers. The speed of sound was measured with a spherical resonator. The volume and thermal expansion of the resonator were determined by weighing the mercury required to fill it at Tt and Tg. The largest part of the standard error in the present determination of Tg is systematic. It results from imperfect knowledge of the thermal expansion of mercury between Tt and Tg. Smaller parts of the error result from imperfections in the measurement of the temperature of the resonator and of the resonance frequencies.

  8. Triple X Egyptian woman and a Down's syndrome offspring

    PubMed Central

    El-Dahtory, Faeza Abdel Mogib

    2013-01-01

    The 47, XXX karyotype (triple X) has a frequency of 1 in 1000 female newborns. However, this karyotype is not usually suspected at birth or childhood. Female patients with a sex chromosome abnormality may be fertile. In patients with a 47, XXX cell line there appears to be an increased risk of a cytogenetically abnormal child but the extent of this risk cannot yet be determined; it is probably lower in the non-mosaic 47, XXX patient than the mosaic 46, XX/47, XXX one. We describe a new rare case of triple X woman and a Down's syndrome offspring. The patient is 26 years of age. She is a housewife, her height is 160 cm and weight is 68 kg and her physical features and mentality are normal. She has had one pregnancy at the age of 25 years resulted in a girl with Down's syndrome. The child had 47 chromosomes with trisomy 21 (47, XX, +21) Figure 1. The patient also has 47 chromosomes with a triple X karyotype (47, XX, +X) Figure 2. The patient's husband (27 years old) is physically and mentally normal. He has 46 chromosomes with a normal XY karyotype (46, XY). There are neither Consanguinity between her parent's nor she and her husband. PMID:23901206

  9. Graft rejection episodes after Descemet stripping with endothelial keratoplasty: part two: the statistical analysis of probability and risk factors.

    PubMed

    Price, M O; Jordan, C S; Moore, G; Price, F W

    2009-03-01

    To investigate risk factors and probability of initial immunological graft rejection episodes after Descemet stripping with endothelial keratoplasty (DSEK). Outcomes of 598 DSEK cases from a single tertiary referral centre were reviewed. Risk factors and probability of rejection were assessed by multivariate Cox proportional hazards modelling. Rejection episodes occurred in 54 eyes of 48 patients. Estimated probability of a rejection episode was 7.6% by 1 year and 12% by 2 years after grafting. Relative risk of rejection was five times higher for African-American patients compared with Caucasians (p = 0.0002). Eyes with pre-existing glaucoma (9%) or steroid-responsive ocular hypertension (27%) had twice the relative risk of rejection (p = 0.045) compared with eyes that did not have those problems. Patient age, sex and corneal diagnosis did not significantly influence rejection risk. Risk of rejection was not increased when fellow eyes were grafted within 1 year of the first eye (p = 0.62). Pre-existing glaucoma or steroid-responsive ocular hypertension and race were the two factors that independently influenced relative risk of rejection after DSEK. Rejection risk was not increased if the fellow eye was grafted within the prior year with DSEK.

  10. Flow through triple helical microchannel

    NASA Astrophysics Data System (ADS)

    Rajbanshi, Pravat; Ghatak, Animangsu

    2018-02-01

    Flow through helical tubes and channels have been examined in different contexts, for facilitating heat and mass transfer at low Reynolds number flow, for generating plug flow to minimize reactor volume for many reactions. The curvature and torsion of the helices have been shown to engender secondary flow in addition to the primary axial flow, which enhances passive in-plane mixing between different fluid streams. Most of these studies, however, involve a single spiral with circular cross-section, which in essence is symmetric. It is not known, however, how the coupled effect of asymmetry of cross-section and the curvature and torsion of channel would affect the flow profile inside such tubes or channels. In this context, we have presented here the analysis of fluid flow at low Reynolds number inside a novel triple helical channel that consists of three helical flow paths joined along their contour length forming a single channel. We have carried out both microparticle image velocimetry (micro-PIV) and 3D simulation in FLUENT of flow of a Newtonian fluid through such channels. Our analysis shows that whereas in conventional single helices, the secondary flow is characterized by two counter-rotating vortices, in the case of triple helical channels, number of such vortices increases with the helix angle. Such flow profile is expected to enhance possibility of mixing between the liquids, yet diminish the pressure drop.

  11. Large (9 mm) Deep Anterior Lamellar Keratoplasty with Clearance of a 6-mm Optical Zone Optimizes Outcomes of Keratoconus Surgery.

    PubMed

    Busin, Massimo; Leon, Pia; Nahum, Yoav; Scorcia, Vincenzo

    2017-07-01

    To evaluate the outcomes of a 9-mm deep anterior lamellar keratoplasty (DALK) with removal of the deep stroma limited to the central 6-mm optical zone. Prospective, noncomparative, interventional case series. A total of 80 consecutive keratoconic eyes without deep stromal scarring, with at least 1 postoperative examination 1 month after complete suture removal. A standardized DALK was performed, including (1) deep trephination of the recipient bed 450 to 550 μm in depth and 9 mm in diameter; (2) pneumatic dissection; (3) debulking of approximately 80% of the anterior stroma; (4) removal of the deep stroma (bubble roof) from a central 6-mm optical zone; and (5) transplantation of a 9-mm anterior corneal lamella cut by microkeratome-assisted dissection (400-μm head) and sutured with a double running 10-0 nylon suture. Success rate and type of pneumatic dissection obtained; best spectacle-corrected visual acuity (BSCVA), refractive astigmatism (RA), and topographic astigmatism (TA), central corneal thickness (CCT) and endothelial cell density 12 months postoperatively; and intraoperative and postoperative complications. Pneumatic dissection created a "big bubble" in 67 of 80 eyes (83.7%), all of them but 1 (1.5%) being of type 1 according to the classification by Dua et al. After complete suture removal, BSCVA averaged 0.09±0.72 logarithm of the minimum angle of resolution (logMAR) and was ≥20/20 in 28 eyes (35%), ≥20/25 in 54 eyes (67.5%), and ≥20/40 in 76 eyes (95%); RA averaged 3.10±1.30 diopters (D), with 73 eyes (91%) within 4.5 D and none above 6 D; regular TA was detected in 72 eyes (90%); mean CCT was 492±62.10 μm; postoperative endothelial cell density averaged 2026±397cells/mm 2 with a mean cell loss of 11.2%. Intraoperative complications included loss of suction (n = 1) and perforation (n = 4). No conversion to penetrating keratoplasty was necessary. After surgery, double anterior chamber was observed in 2 cases (2.5%), both managed

  12. CURCUMIN IN COMBINATION WITH TRIPLE THERAPY REGIMES AMELIORATES OXIDATIVE STRESS AND HISTOPATHOLOGIC CHANGES IN CHRONIC GASTRITIS-ASSOCIATED HELICOBACTER PYLORI INFECTION.

    PubMed

    Judaki, Arezu; Rahmani, Asghar; Feizi, Jalil; Asadollahi, Khairollah; Hafezi Ahmadi, Mohammad Reza

    2017-01-01

    Helicobacter pylori (H. pylori) gastric infection is a main cause of inflammatory changes and gastric cancers. The aim of this study was finding the effects of curcumin on oxidative stress and histological changes in chronic gastritis associated with H. pylori. In a randomized clinical trial, patients were divided into two groups: a standard triple therapy group and triple therapy with curcumin group. Endoscopic and histological examinations were measured for all patients before and after 8 weeks. Triple therapy with curcumin treatment group significantly decreased malondialdehyde markers, glutathione peroxides and increased total antioxidant capacity of the gastric mucosa at the end of study compared to baseline and triple regimen groups. In addition, the oxidative damage to DNA was significantly decreased in triple therapy with curcumin group at the end of study compared to baseline and compared to triple therapy (P<0.05 for both). Triple therapy group in combination with Curcumin significantly decreased all active, chronic and endoscopic inflammation scores of patients compared to the baseline and triple therapy group (P<0.05 for both). The eradication rate by triple therapy + curcumin was significantly increased compared to triple therapy alone (P<0.05). Curcumin can be a useful supplement to improve chronic inflammation and prevention of carcinogenic changes in patients with chronic gastritis associated by H. pylori.

  13. Therapeutic Implications of the Molecular and Immune Landscape of Triple-Negative Breast Cancer.

    PubMed

    Gregório, Ana C; Lacerda, Manuela; Figueiredo, Paulo; Simões, Sérgio; Dias, Sérgio; Moreira, João Nuno

    2017-09-14

    Treatment and management of breast cancer imposes a heavy burden on public health care, and incidence rates continue to increase. Breast cancer is the most common female neoplasia and primary cause of death among women worldwide. The recognition of breast cancer as a complex and heterogeneous disease, comprising different molecular entities, was a landmark in our understanding of this malignancy. Valuing the impact of the molecular characteristics on tumor behavior enabled a better assessment of a patient's prognosis and increased the predictive power to therapeutic response and clinical outcome. Molecular heterogeneity is also prominent in the triple-negative breast cancer subtype, and is reflected by the distinct prognostic and patient's sensitivity to treatment, being chemotherapy the only systemic treatment currently available. From a therapeutic perspective, gene expression profiling of triple-negative tumors has notably contributed to the exploration of new druggable targets and brought to light the need to align these patients to the various therapies according to their triple-negative subtype. Additionally, the higher amount of tumor infiltrating lymphocytes, and the prevalence of an increased expression of PD-1 receptor and its ligand, PD-L1, in triple-negative tumors, created a new treatment opportunity with immune checkpoint inhibitors. This manuscript addresses the current knowledge on the molecular and immune profiles of breast cancer, and its impact on the development of targeted therapies, with a particular emphasis on the triple-negative subtype.

  14. Triple combination antibiotic therapy for carbapenemase-producing Klebsiella pneumoniae: a systematic review.

    PubMed

    Jacobs, David M; Safir, M Courtney; Huang, Dennis; Minhaj, Faisal; Parker, Adam; Rao, Gauri G

    2017-11-25

    The spread of carbapenemase-producing K. pneumoniae (CPKP) has become a significant problem worldwide. Combination therapy for CPKP is encouraging, but polymyxin resistance to many antibiotics is hampering effective treatment. Combination therapy with three or more antibiotics is being increasingly reported, therefore we performed a systematic review of triple combination cases in an effort to evaluate their clinical effectiveness for CPKP infections. The PubMed database was searched to identify all published clinical outcomes of CPKP infections treated with triple combination therapy. Articles were stratified into two tiers depending on the level of clinical detail provided. A tier 1 study included: antibiotic regimen, regimen-specific outcome, patient status at onset of infection, and source of infection. Articles not reaching these criteria were considered tier 2. Thirty-three studies were eligible, 23 tier 1 and ten tier 2. Among tier 1 studies, 53 cases were included in this analysis. The most common infection was pneumonia (31%) followed by primary or catheter-related bacteremia (21%) and urinary tract infection (17%). Different combinations of antibiotic classes were utilized in triple combinations, the most common being a polymyxin (colistin or polymyxin B, 86.8%), tigecycline (73.6%), aminoglycoside (43.4%), or carbapenem (43.4%). Clinical and microbiological failure occurred in 14/39 patients (35.9%) and 22/42 patients (52.4%), respectively. Overall mortality for patients treated with triple combination therapy was 35.8% (19/53 patients). Triple combination therapy is being considered as a treatment option for CPKP. Polymyxin-based therapy is the backbone antibiotic in these regimens, but its effectiveness needs establishing in prospective clinical trials.

  15. Novel technique for the preparation of corneal grafts for descemet membrane endothelial keratoplasty.

    PubMed

    Muraine, Marc; Gueudry, Julie; He, Zhiguo; Piselli, Simone; Lefevre, Sabine; Toubeau, David

    2013-11-01

    To report a simple novel technique to facilitate preparation of Descemet membrane grafts for Descemet membrane endothelial keratoplasty (DMEK). Laboratory investigation and retrospective, single-center, consecutive case series. Preparation of the endothelial graft is performed on an artificial anterior chamber, endothelial side up. After an incomplete circular superficial trephination, we describe a simple technique using a 27 gauge cannula to detach the Descemet membrane (DM). Endothelial cell density (ECD) was measured before dissection on 12 human corneas for research and 3 days after storage in organ culture. Histologic and electron microscopy analysis were performed. A DMEK was performed in 50 patients with Fuchs dystrophy. Visual acuity and ECD were evaluated 2 and 6 months after surgery. ECD was 2765 ± 256 cells/mm(2) on corneas for research before dissection and 2651 ± 305 cells/mm(2) after 3 days in organ culture (P < .01). Histologic and electronic sections confirm that the cleavage was between DM and posterior stroma. Clinically, preparation of 2 corneas from a single donor was unsuccessful; 48 corneas were clear at 2 months and 47 at 6 months. At 2 months 77% of the patients had recovered a visual acuity of at least 20/30. At 6 months, 91.5% of the patients had a visual acuity of at least 20/30. ECD was 2656 ± 28 cells/mm(2) (range: 2450-3100 cells/mm(2)) preoperatively, 1797 ± 41 cells/mm(2) (range: 1100-2700 cells/mm(2)) at 2 months, and 1658 ± 43 cells/mm(2) (range: 900-2600 cells/mm(2)) at 6 months. We report here a reliable and efficient technique for the preparation of pure Descemet membrane grafts. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Triple vs Dual Antithrombotic Therapy in Patients with Atrial Fibrillation and Coronary Artery Disease.

    PubMed

    Lopes, Renato D; Rao, Meena; Simon, DaJuanicia N; Thomas, Laine; Ansell, Jack; Fonarow, Gregg C; Gersh, Bernard J; Go, Alan S; Hylek, Elaine M; Kowey, Peter; Piccini, Jonathan P; Singer, Daniel E; Chang, Paul; Peterson, Eric D; Mahaffey, Kenneth W

    2016-06-01

    The role of triple antithrombotic therapy vs dual antithrombotic therapy in patients with both atrial fibrillation and coronary artery disease remains unclear. This study explores the differences in treatment practices and outcomes between triple antithrombotic therapy and dual antithrombotic therapy in patients with atrial fibrillation and coronary artery disease. Using the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (n = 10,135), we analyzed outcomes in patients with coronary artery disease (n = 1827) according to treatment with triple antithrombotic therapy (defined as concurrent therapy with an oral anticoagulant, a thienopyridine, and aspirin) or dual antithrombotic therapy (comprising either an oral anticoagulant and one antiplatelet agent [OAC plus AA] or 2 antiplatelet drugs and no anticoagulant [DAP]). The use of triple antithrombotic therapy, OAC plus AA, and DAP at baseline was 8.5% (n = 155), 80.4% (n = 1468), and 11.2% (n = 204), respectively. Among patients treated with OAC plus AA, aspirin was the most common antiplatelet agent used (90%), followed by clopidogrel (10%) and prasugrel (0.1%). The use of triple antithrombotic therapy was not affected by patient risk of either stroke or bleeding. Patients treated with triple antithrombotic therapy at baseline were hospitalized for all causes (including cardiovascular) more often than patients on OAC plus AA (adjusted hazard ratio 1.75; 95% confidence interval, 1.35-2.26; P <.0001) or DAP (hazard ratio 1.82; 95% confidence interval, 1.25-2.65; P = .0018). Rates of major bleeding or a combined cardiovascular outcome were not significantly different by treatment group. Choice of antithrombotic therapy in patients with atrial fibrillation and coronary artery disease was not affected by patient stroke or bleeding risks. Triple antithrombotic therapy-treated patients were more likely to be hospitalized for all causes than those on OAC plus AA or on DAP. Copyright © 2016 The

  17. Bladder exstrophy-epispadias complex and triple-X syndrome: incidental finding or causality?

    PubMed

    Ramaekers, Paul; Loeys, Bart; von Lowtzow, Catharina; Reutter, Heiko; Leroy, Yves; Colpaert, Cécile; Blaumeiser, Bettina; Janssens, Katrien; Parizel, Maxim; Jacquemyn, Yves

    2014-10-01

    Bladder exstrophy is a rare malformation. Prenatal diagnosis is usually an incidental finding on routine ultrasound examination. Triple-X syndrome (karyotype 47,XXX) is the most frequent sex chromosome aneuploidy in live-born females (approximately 1 in 1000). The diagnosis is often not made because women with 47,XXX karyotype have no or hardly any clinical symptoms during life. Prenatal diagnosis of triple X karyotype is usually an incidental finding when an invasive prenatal diagnosis is performed for other reasons. Here, we report on two cases with bladder exstrophy and triple-X syndrome, one in a fetus and one in an adult. In view of two previous reports of this association in literature, causality of these two conditions should be considered. A gene dosage effect as possible underlying mechanisms will be discussed. © 2014 Wiley Periodicals, Inc.

  18. Design and fabrication of high-performance diamond triple-gate field-effect transistors

    PubMed Central

    Liu, Jiangwei; Ohsato, Hirotaka; Wang, Xi; Liao, Meiyong; Koide, Yasuo

    2016-01-01

    The lack of large-area single-crystal diamond wafers has led us to downscale diamond electronic devices. Here, we design and fabricate a hydrogenated diamond (H-diamond) triple-gate metal-oxide-semiconductor field-effect transistor (MOSFET) to extend device downscaling and increase device output current. The device’s electrical properties are compared with those of planar-type MOSFETs, which are fabricated simultaneously on the same substrate. The triple-gate MOSFET’s output current (174.2 mA mm−1) is much higher than that of the planar-type device (45.2 mA mm−1), and the on/off ratio and subthreshold swing are more than 108 and as low as 110 mV dec−1, respectively. The fabrication of these H-diamond triple-gate MOSFETs will drive diamond electronic device development forward towards practical applications. PMID:27708372

  19. SDSS J1056+5516: A Triple AGN or an SMBH Recoil Candidate?

    NASA Astrophysics Data System (ADS)

    Kalfountzou, E.; Santos Lleo, M.; Trichas, M.

    2017-12-01

    We report the discovery of a kiloparsec-scale triple supermassive black hole system at z = 0.256: SDSS J1056+5516, discovered by our systematic search for binary quasars. The system contains three strong emission-line nuclei, which are offset by < 250 {km} {{{s}}}-1 and by 15-18 kpc in projected separation, suggesting that the nuclei belong to the same physical structure. The system includes a tidal arm feature spanning ˜100 kpc in projected distance at the systems’ redshift, inhabiting an ongoing or recent galaxy merger. Based on our results, such a structure can only satisfy one of the three scenarios; a triple supermasive black hole (SMBH) interacting system, a triple AGN, or a recoiling SMBH. Each of these scenarios is unique for our understanding of the hierarchical growth of galaxies, AGN triggering, and gravitational waves.

  20. Elevation of north facades of #156158 (triple wards) National ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Elevation of north facades of #156-158 (triple wards) - National Home for Disabled Volunteer Soldiers, Pacific Branch, Mental Health Buildings, 11301 Wilshire Boulevard, West Los Angeles, Los Angeles County, CA

  1. GDC-0941 and Cisplatin in Treating Patients With Androgen Receptor-Negative Triple Negative Metastatic Breast Cancer

    ClinicalTrials.gov

    2017-05-22

    Estrogen Receptor Negative Breast Cancer; Human Epidermal Growth Factor 2 Negative Carcinoma of Breast; Triple Negative Breast Cancer; Recurrent Breast Cancer; Stage IV Breast Cancer; Triple-negative Breast Cancer

  2. Analytic reconstruction algorithms for triple-source CT with horizontal data truncation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Ming; Yu, Hengyong, E-mail: hengyong-yu@ieee.org

    2015-10-15

    Purpose: This paper explores a triple-source imaging method with horizontal data truncation to enlarge the field of view (FOV) for big objects. Methods: The study is conducted by using theoretical analysis, mathematical deduction, and numerical simulations. The proposed algorithms are implemented in c + + and MATLAB. While the basic platform is constructed in MATLAB, the computationally intensive segments are coded in c + +, which are linked via a MEX interface. Results: A triple-source circular scanning configuration with horizontal data truncation is developed, where three pairs of x-ray sources and detectors are unevenly distributed on the same circle tomore » cover the whole imaging object. For this triple-source configuration, a fan-beam filtered backprojection-type algorithm is derived for truncated full-scan projections without data rebinning. The algorithm is also extended for horizontally truncated half-scan projections and cone-beam projections in a Feldkamp-type framework. Using their method, the FOV is enlarged twofold to threefold to scan bigger objects with high speed and quality. The numerical simulation results confirm the correctness and effectiveness of the developed algorithms. Conclusions: The triple-source scanning configuration with horizontal data truncation cannot only keep most of the advantages of a traditional multisource system but also cover a larger FOV for big imaging objects. In addition, because the filtering is shift-invariant, the proposed algorithms are very fast and easily parallelized on graphic processing units.« less

  3. Explicitly correlated coupled-cluster theory using cusp conditions. II. Treatment of connected triple excitations.

    PubMed

    Köhn, Andreas

    2010-11-07

    The coupled-cluster singles and doubles method augmented with single Slater-type correlation factors (CCSD-F12) determined by the cusp conditions (also denoted as SP ansatz) yields results close to the basis set limit with only small overhead compared to conventional CCSD. Quantitative calculations on many-electron systems, however, require to include the effect of connected triple excitations at least. In this contribution, the recently proposed [A. Köhn, J. Chem. Phys. 130, 131101 (2009)] extended SP ansatz and its application to the noniterative triples correction CCSD(T) is reviewed. The approach allows to include explicit correlation into connected triple excitations without introducing additional unknown parameters. The explicit expressions are presented and analyzed, and possible simplifications to arrive at a computationally efficient scheme are suggested. Numerical tests based on an implementation obtained by an automated approach are presented. Using a partial wave expansion for the neon atom, we can show that the proposed ansatz indeed leads to the expected (L(max)+1)(-7) convergence of the noniterative triples correction, where L(max) is the maximum angular momentum in the orbital expansion. Further results are reported for a test set of 29 molecules, employing Peterson's F12-optimized basis sets. We find that the customary approach of using the conventional noniterative triples correction on top of a CCSD-F12 calculation leads to significant basis set errors. This, however, is not always directly visible for total CCSD(T) energies due to fortuitous error compensation. The new approach offers a thoroughly explicitly correlated CCSD(T)-F12 method with improved basis set convergence of the triples contributions to both total and relative energies.

  4. Craniofacial and dental manifestations of triple X syndrome associated with congenital hypothyroidism: a case report.

    PubMed

    Ferrazzo, Kívia Linhares; Payeras, Marcia Rodrigues; Ferrazzo, Vilmar Antonio; Mezomo, Maurício Barbieri

    2014-01-01

    Triple X syndrome (47,XXX) is a numerical chromosomal alteration that affects 1/1,000 women, in which the woman is born with an extra X chromosome. Some oral changes have been reported in the literature, as hypodontia, influence on deposition of crown enamel and discrepancies in cephalometric measurements. Other systemic complications may lead to oral abnormalities similar to those seen in triple X patients, such as congenital hypothyroidism (CH). This paper reports a triple X syndrome case associated with CH later treated. Besides delay in cognitive and intellectual development, the patient had changes in teeth development and in cephalometric measurements with deficiencies in the maxilla and mandible. This is the first report of a triple X syndrome associated with CH. Both conditions may result in changes in dentofacial development. © 2013 Special Care Dentistry Association and Wiley Periodicals, Inc.

  5. A new triple system DNA-Nanosilver-Berberine for cancer therapy

    NASA Astrophysics Data System (ADS)

    Grebinyk, Anna; Yashchuk, Valeriy; Bashmakova, Nataliya; Gryn, Dmytro; Hagemann, Tobias; Naumenko, Antonina; Kutsevol, Nataliya; Dandekar, Thomas; Frohme, Marcus

    2018-03-01

    The isoquinoline quaternary alkaloid Berberine possesses a variety of pharmacological properties that suggests its promising application for an anticancer delivery system design utilizing its ability to intercalate DNA. In the current work, we have investigated the effects of Berberine on the human T cell leukemia cell line in vitro. Fluorescent microscopy of leukemic cells revealed Berberine nuclear localization. The results showed that Berberine inhibited leukemic cell growth in a time- and dose-dependent manner, that was associated with reactive oxygen species production intensification and caspase 3/7 activity increase with followed apoptosis induction. Berberine was used as a toxic and phototoxic agent for triple system synthesis along with DNA as a carrier and nanosilver as a plasmonic accelerator of Berberine electronic transitions and high energy emission absorbent centers. The proposed method allows to obtain the complex of DNA with Berberine molecules and silver nanoparticles. The optical properties of free components as well as their various combinations, including the final triple system DNA-Nanosilver-Berberine, were investigated. Obtained results support the possibility to use the triple system DNA-Nanosilver-Berberine as an alternative therapeutic agent for cancer treatment.

  6. Triple aim program: assessing its effectiveness as a hospital management tool.

    PubMed

    Coyne, Joseph S; Hilsenrath, Peter E; Arbuckle, Barry S; Kureshy, Fareed; Vaughan, David; Grayson, David; Saygin, Tuba

    2014-01-01

    According to a recent national survey of Hospital chief executive officers, financial challenges are their top concern, especially government reimbursement. Moreover, the patient faces greater deductibles forcing hospitals to prioritize price transparency. The Triple Aim program is a tool available to hospital management to help address these challenges. This study indicates that the Triple Aim is valuable to healthcare providers and patients by reducing medical errors, improving healthcare quality, and reducing costs on a per capita basis. Managerial implications are discussed for hospitals and health systems considering this approach to addressing financial challenges.

  7. Glyceollins as novel targeted therapeutic for the treatment of metastatic triple-negative breast cancer

    USDA-ARS?s Scientific Manuscript database

    The purpose of this study was to investigate the effects of glyceollins on the suppression of tumorigenesis in triple negative breast carcinoma cell lines. We further explored the effects of glyceollins on microRNA and protein expression in MDA MB 231 cells. Triple negative (ER , PgR, and Her2/neu ...

  8. Sweating of Descemet’s membrane during deep anterior lamellar keratoplasty in absence of perforation

    PubMed Central

    Mohamed-Noriega, Karim; Mehta, Jodhbir S

    2012-01-01

    We report a case of spontaneous Descemet’s membrane sweating of aqueous humor during a manual deep anterior lamellar keratoplasty (DALK) without perforation of Descemet’s membrane. An 81-year-old female developed a neurotrophic central ulcer with descemetocele in the right eye, and her visual acuity was count fingers at 30 cm. She was unresponsive to medical treatment, and an uneventful manual DALK was performed. Six months after surgery, unaided visual acuity improved to 6/30. Seven months after surgery, the patient had a decrease in visual acuity to count fingers in the same eye. She was diagnosed as having corneal melting with a central descemetocele in the previous lamellar graft. A repeat manual DALK graft was performed. Lamellar dissection was performed starting from the edge of descemetocele, proceeding to the corneal periphery and maintaining the surgical plane of the previous DALK. During the surgical procedure, continuous and localized sweating of aqueous through Descemet’s membrane was observed in the area of the descemetocele. After drying of the recipient bed, no visible perforation of Descemet’s membrane was found. After removal of the previous DALK graft, a new stromal lamellar graft was sutured. The surgery was concluded without complications. One day after surgery, the graft was clear, with no detachment of Descemet’s membrane. If Descemet’s membrane sweating is observed during DALK and there is no visible perforation, the reason may be a hidden micron perforation in an intact Descemet’s membrane. It is recommended to continue with surgery maintaining maximum diligence and low intraocular pressure to prevent extension of micron perforation. PMID:23055660

  9. Effect of Descemet Membrane Endothelial Keratoplasty on Color Vision in Patients With Fuchs Dystrophy.

    PubMed

    Price, David A; Price, Marianne O; Lopez, Amanda; Price, Francis W

    2016-08-01

    To assess changes in color discernment after Descemet membrane endothelial keratoplasty (DMEK) in patients with Fuchs endothelial corneal dystrophy (FECD). In this prospective, single-center study, the study group was composed of 26 patients with FECD, aged 46 to 85 years, who underwent DMEK as a single surgical procedure; 24 (92%) had pseudophakic and 2 (8%) had phakic eyes. The patients completed a computerized Farnsworth-Munsell 100-hue color vision test before and 1 month after DMEK. A control group of 14 subjects, aged 57 to 85 years, was tested 1 month after cataract surgery. The median number of errors made by patients who had undergone DMEK on the color vision test improved from 64 (range 24-124) before surgery to 48 (range 10-120) after surgery (P = 0.0053). The post-DMEK scores in the 24 patients with pseudophakic eyes (median = 48, range = 10-120) were comparable to those of an age-matched control group of patients with cataract without corneal abnormalities (median = 53, range = 4-104, P = 0.88). The improvement in color vision was not correlated with the amount of improvement in best corrected visual acuity (r = -0.02, P = 0.91) or with the reduction in central pachymetry (r = -0.08, P = 0.71) after DMEK. Consistent with spontaneous comments from some patients with FECD that colors appear more vivid after DMEK, a comparison of pre- and postoperative color vision scores showed that color discernment usually improved after DMEK (81%). The lack of correlation between color vision improvement and pachymetry reduction leads us to hypothesize that color vision improvement may relate to removal of the guttae associated with FECD.

  10. A Novel Tectonic Keratoplasty with Femtosecond Laser Intrastromal Lenticule for Corneal Ulcer and Perforation

    PubMed Central

    Jiang, Yang; Li, Ying; Liu, Xiao-Wei; Xu, Jing

    2016-01-01

    Background: Small incision refractive lenticule extraction (SMILE) is an effective laser procedure that treats myopia. This research was to describe a novel approach to treat corneal ulcer or perforation using the corneal lenticules obtained from SMILE and to evaluate the safety and effectiveness of tectonic keratoplasty with femtosecond laser intrastromal lenticule (TEKIL). Methods: A total of twenty patients (22 eyes) were monitored for at least 6 months and were assessed using slit lamp microscopy, optical coherence tomography, and best-corrected visual acuity (BCVA). Postoperative complications throughout the study period were recorded. Results: Corneal ulcer in 14 patients (16 eyes) and corneal perforation in six patients (6 eyes) were treated with TEKIL. The patients were ten females and ten males, with a mean age of 58.5 ± 16.3 years (range: 16–81 years). In this study, the most causes of corneal ulcer or perforation were immunologic causes (54.5%). After TEKIL procedure, global integrity was achieved in all cases. No immune rejection or perforation was detected. The mean BCVA improved from 0.17 ± 0.20 preoperatively to 0.27 ± 0.25 postoperatively at the final follow-up (t = 2.095, P = 0.052). The postoperative BCVA improved in 12 eyes (54.5%) and maintained in nine eyes (40.9%). Vision function successfully maintained in all eyes (100%). In three cases, corneal ulcers were treated by reoperation of TEKIL at 3 months after the initial surgery for the reason that the residual corneal thickness was <250 μm. Conclusions: TEKIL seems to be an effective treatment for corneal ulcer and perforation in the condition of emergency and donor shortage. PMID:27453231

  11. Beyond triple collocation: Applications to satellite soil moisture

    USDA-ARS?s Scientific Manuscript database

    Triple collocation is now routinely used to resolve the exact (linear) relationships between multiple measurements and/or representations of a geophysical variable that are subject to errors. It has been utilized in the context of calibration, rescaling and error characterisation to allow comparison...

  12. Mechanism of triple-color phase oscillators

    NASA Astrophysics Data System (ADS)

    Pun, Kwok C.

    1998-08-01

    A realistic model has been developed for a barium titanate triple-color phase oscillator based on the mechanism of polarizabililty and quantum mechanics. It helps to explain some of the difficult phenomena of the phase oscillator. As a result, with the clear understanding, we can seek betterment of the oscillator as a photonic switch as well as a one color writing and another color displaying no cross talk advance information exchanger.

  13. Simulation of Triple Oxidation Ditch Wastewater Treatment Process

    NASA Astrophysics Data System (ADS)

    Yang, Yue; Zhang, Jinsong; Liu, Lixiang; Hu, Yongfeng; Xu, Ziming

    2010-11-01

    This paper presented the modeling mechanism and method of a sewage treatment system. A triple oxidation ditch process of a WWTP was simulated based on activated sludge model ASM2D with GPS-X software. In order to identify the adequate model structure to be implemented into the GPS-X environment, the oxidation ditch was divided into several completely stirred tank reactors depended on the distribution of aeration devices and dissolved oxygen concentration. The removal efficiency of COD, ammonia nitrogen, total nitrogen, total phosphorus and SS were simulated by GPS-X software with influent quality data of this WWTP from June to August 2009, to investigate the differences between the simulated results and the actual results. The results showed that, the simulated values could well reflect the actual condition of the triple oxidation ditch process. Mathematical modeling method was appropriate in effluent quality predicting and process optimizing.

  14. Immunotherapeutic interventions of Triple Negative Breast Cancer.

    PubMed

    Li, Zehuan; Qiu, Yiran; Lu, Weiqi; Jiang, Ying; Wang, Jin

    2018-05-30

    Triple Negative Breast Cancer (TNBC) is a highly heterogeneous subtype of breast cancer that lacks the expression of oestrogen receptors, progesterone receptors and human epidermal growth factor receptor 2. Although TNBC is sensitive to chemotherapy, the overall outcomes of TNBC are worse than for other breast cancers, and TNBC is still one of the most fatal diseases for women. With the discovery of antigens specifically expressed in TNBC cells and the developing technology of monoclonal antibodies, chimeric antigen receptors and cancer vaccines, immunotherapy is emerging as a novel promising option for TNBC. This review is mainly focused on the tumour microenvironment and host immunity, Triple Negative Breast Cancer and the clinical treatment of TNBC, novel therapies for cancer and immunotherapy for TNBC, and the future outlook for the treatment for TNBC and the interplay between the therapies, including immune checkpoint inhibitors, combination of immune checkpoint inhibitors with targeted treatments in TNBC, adoptive cell therapy, cancer vaccines. The review also highlights recent reports on the synergistic effects of immunotherapy and chemotherapy, antibody-drug conjugates, and exosomes, as potential multifunctional therapeutic agents in TNBC.

  15. Triple galaxies and a hidden mass problem

    NASA Technical Reports Server (NTRS)

    Karachentsev, I. D.; Karachentseva, V. E.; Lebedev, V. S.

    1990-01-01

    The authors consider a homogeneous sample of 84 triple systems of galaxies with components brighter than m = 15.7, located in the northern sky and satisfying an isolation criterion with respect to neighboring galaxies in projection. The distributions of basic dynamical parameters for triplets have median values as follows: radial velocity dispersion 133 km/s, mean harmonic radius 63 kpc, absolute magnitude of galaxies M sub B equals -20.38, crossing time tau = 0.04 H(sup minus 1). For different ways of estimation the median mass-to-luminosity ratio is (20 - 30). A comparison of the last value with the ones for single and binary galaxies shows the presence of a virial mass excess for triplets by a factor 4. The mass-to-luminosity ratio is practically uncorrelated with linear size of triplets or with morphological types of their components. We note that a significant part of the virial excess may be explained by the presence of nonisolated triple configurations in the sample, which are produced by debris of more populous groups of galaxies.

  16. Triple shape memory effects of cross-linked polyethylene/polypropylene blends with cocontinuous architecture.

    PubMed

    Zhao, Jun; Chen, Min; Wang, Xiaoyan; Zhao, Xiaodong; Wang, Zhenwen; Dang, Zhi-Min; Ma, Lan; Hu, Guo-Hua; Chen, Fenghua

    2013-06-26

    In this paper, the triple shape memory effects (SMEs) observed in chemically cross-linked polyethylene (PE)/polypropylene (PP) blends with cocontinuous architecture are systematically investigated. The cocontinuous window of typical immiscible PE/PP blends is the volume fraction of PE (v(PE)) of ca. 30-70 vol %. This architecture can be stabilized by chemical cross-linking. Different initiators, 2,5-dimethyl-2,5-di(tert-butylperoxy)-hexane (DHBP), dicumylperoxide (DCP) coupled with divinylbenzene (DVB) (DCP-DVB), and their mixture (DHBP/DCP-DVB), are used for the cross-linking. According to the differential scanning calorimetry (DSC) measurements and gel fraction calculations, DHBP produces the best cross-linking and DCP-DVB the worst, and the mixture, DHBP/DCP-DVB, is in between. The chemical cross-linking causes lower melting temperature (Tm) and smaller melting enthalpy (ΔHm). The prepared triple shape memory polymers (SMPs) by cocontinuous immiscible PE/PP blends with v(PE) of 50 vol % show pronounced triple SMEs in the dynamic mechanical thermal analysis (DMTA) and visual observation. This new strategy of chemically cross-linked immiscible blends with cocontinuous architecture can be used to design and prepare new SMPs with triple SMEs.

  17. Analysis of the heat transfer in double and triple concentric tube heat exchangers

    NASA Astrophysics Data System (ADS)

    Rădulescu, S.; Negoiţă, L. I.; Onuţu, I.

    2016-08-01

    The tubular heat exchangers (shell and tube heat exchangers and concentric tube heat exchangers) represent an important category of equipment in the petroleum refineries and are used for heating, pre-heating, cooling, condensation and evaporation purposes. The paper presents results of analysis of the heat transfer to cool a petroleum product in two types of concentric tube heat exchangers: double and triple concentric tube heat exchangers. The cooling agent is water. The triple concentric tube heat exchanger is a modified constructive version of double concentric tube heat exchanger by adding an intermediate tube. This intermediate tube improves the heat transfer by increasing the heat area per unit length. The analysis of the heat transfer is made using experimental data obtained during the tests in a double and triple concentric tube heat exchanger. The flow rates of fluids, inlet and outlet temperatures of water and petroleum product are used in determining the performance of both heat exchangers. Principally, for both apparatus are calculated the overall heat transfer coefficients and the heat exchange surfaces. The presented results shows that triple concentric tube heat exchangers provide better heat transfer efficiencies compared to the double concentric tube heat exchangers.

  18. New Approaches Towards Recognition of Nucleic Acid Triple Helices

    PubMed Central

    Arya, Dev P.

    2012-01-01

    We show that groove recognition of nucleic acid triple helices can be achieved with aminosugars. Among these aminosugars, neomycin is the most effective aminoglycoside (groove binder) for stabilizing a DNA triple helix. It stabilizes both the T·A·T triplex and mixed-base DNA triplexes better than known DNA minor groove binders (which usually destabilize the triplex) and polyamines. Neomycin selectively stabilizes the triplex (T·A·T and mixed base) without any effect on the DNA duplex. The selectivity of neomycin likely originates from its potential and shape complementarity to the triplex Watson–Hoogsteen groove, making it the first molecule that selectively recognizes a triplex groove over a duplex groove. The groove recognition of aminoglycosides is not limited to DNA triplexes, but also extends to RNA and hybrid triple helical structures. Intercalator–neomycin conjugates are shown to simultaneously probe the base stacking and groove surface in the DNA triplex. Calorimetric and spectrosocopic studies allow the quantification of the effect of surface area of the intercalating moiety on binding to the triplex. These studies outline a novel approach to the recognition of DNA triplexes that incorporates the use of non-competing binding sites. These principles of dual recognition should be applicable to the design of ligands that can bind any given nucleic acid target with nanomolar affinities and with high selectivity. PMID:21073199

  19. Layout compliance for triple patterning lithography: an iterative approach

    NASA Astrophysics Data System (ADS)

    Yu, Bei; Garreton, Gilda; Pan, David Z.

    2014-10-01

    As the semiconductor process further scales down, the industry encounters many lithography-related issues. In the 14nm logic node and beyond, triple patterning lithography (TPL) is one of the most promising techniques for Metal1 layer and possibly Via0 layer. As one of the most challenging problems in TPL, recently layout decomposition efforts have received more attention from both industry and academia. Ideally the decomposer should point out locations in the layout that are not triple patterning decomposable and therefore manual intervention by designers is required. A traditional decomposition flow would be an iterative process, where each iteration consists of an automatic layout decomposition step and manual layout modification task. However, due to the NP-hardness of triple patterning layout decomposition, automatic full chip level layout decomposition requires long computational time and therefore design closure issues continue to linger around in the traditional flow. Challenged by this issue, we present a novel incremental layout decomposition framework to facilitate accelerated iterative decomposition. In the first iteration, our decomposer not only points out all conflicts, but also provides the suggestions to fix them. After the layout modification, instead of solving the full chip problem from scratch, our decomposer can provide a quick solution for a selected portion of layout. We believe this framework is efficient, in terms of performance and designer friendly.

  20. Realization of the Gallium Triple Point at NMIJ/AIST

    NASA Astrophysics Data System (ADS)

    Nakano, T.; Tamura, O.; Sakurai, H.

    2008-02-01

    The triple point of gallium has been realized by a calorimetric method using capsule-type standard platinum resistance thermometers (CSPRTs) and a small glass cell containing about 97 mmol (6.8 g) of gallium with a nominal purity of 99.99999%. The melting curve shows a very flat and relatively linear dependence on 1/ F in the region from 1/ F = 1 to 1/ F = 20 with a narrow width of the melting curve within 0.1 mK. Also, a large gallium triple-point cell was fabricated for the calibration of client-owned CSPRTs. The gallium triple-point cell consists of a PTFE crucible and a PTFE cap with a re-entrant well and a small vent. The PTFE cell contains 780 g of gallium from the same source as used for the small glass cell. The PTFE cell is completely covered by a stainless-steel jacket with a valve to enable evacuation of the cell. The melting curve of the large cell shows a flat plateau that remains within 0.03 mK over 10 days and that is reproducible within 0.05 mK over 8 months. The calibrated value of a CSPRT obtained using the large cell agrees with that obtained using the small glass cell within the uncertainties of the calibrations.

  1. Clinical outcomes of Descemet membrane endothelial keratoplasty using eye bank-prepared tissues.

    PubMed

    Deng, Sophie X; Sanchez, P James; Chen, Luxia

    2015-03-01

    To investigate the outcomes of Descemet membrane endothelial keratoplasty (DMEK) using prestripped donor tissue prepared by an eye bank. Retrospective, noncomparative case series. This retrospective, noncomparative, observational study investigated the outcomes of the first 40 consecutive DMEK procedures performed by a single surgeon using prestripped tissues prepared by a single eye bank during the period September 17, 2013 to July 1, 2014. A new technique to unfold the Descemet membrane grafts using a single cannula was described. Medical records were reviewed to obtain the prestripped and poststripped endothelial cell counts (ECC), postoperative ECC, visual acuity measurements, and complications. Of the 43 prestripped tissues received, 40 were transplanted. The leading indications for DMEK were Fuchs endothelial corneal dystrophy (n = 28) and bullous keratopathy (n = 11). Nine DMEK procedures were performed in combination with phacoemulsification and posterior chamber intraocular lens implantation. Six patients had undergone prior glaucoma surgeries. The mean follow-up duration was 5.3 months (range, 1 week to 11 months). Preoperative spectacle-corrected visual acuity was ≤20/200 in 8 patients (20%) and ≤20/40 in 37 patients (92.5%). Primary graft failure occurred in the first case. Thirty-eight patients had improved vision postoperatively. Among the 39 patients who had successful DMEK, postoperative BCVA was ≥20/20 in 20 patients (51.2%), ≥20/25 in 30 patients (76.9%), and ≥20/40 in 34 patients (87.2%) by the last follow-up. There was no secondary graft failure. Rejection occurred in 2 patients because of self-discontinuation of topical corticosteroid. The most common complication was partial detachment requiring air injection (11 of 40 patients; 27.5%). Mean ECC loss after stripping of Descemet membrane was 3.9% (range, 6.5% gain to 14.5% loss). During the first 6 months after transplantation, the average ECC loss was 30.5% (range, 3.8%-67.4% loss

  2. Triple Test in Carcinoma Breast

    PubMed Central

    Sameer; Mukherjee, Arindam

    2014-01-01

    Introduction: The commonest clinical presentation in majority of breast pathology is a lump. A definite diagnosis of breast lump is very important for the surgeon to decide on the final course of treatment and also saves the patient from unnecessary physical, emotional and psychological trauma if there is a definite preoperative diagnosis of benign lesion. The present study was done to evaluate the effectiveness and relevance of “TRIPLE TEST”in diagnosis of carcinoma breast in rural labour class population. Materials and Methods: The present study was a prospective study conducted on patients over 35 years of age having palpable breast lumps presenting in the out patient department of general surgery, ESI Hospital Basaidarapur New Delhi, India. The duration of study was from May 2007 to June 2009 and a total of 100 cases were studied. Each patient was subjected to a detailed history, clinical breast examination ,diagnostic mammography and FNAC. In this study, the results of each modality was divided in three groups: benign, suspicious and malignant. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of each test was calculated individually and as combined. Result: Out of 100 patients enrolled in this study, 60 cases were benign and 40 cases were of malignant breast disease. The age of patients with carcinoma breast in the series varied from 35 years to 70 years. The highest incidence of malignancy noted was 30% in 41-50 years age group (4th decade) followed by 27.5% in 51-60 years age group (5th decade). The sensitivity of clinical examination was found to be 75%, specificity was 83.3%, positive predictive value (PPV) of 75% and diagnostic accuracy of 80%. The sensitivity, specificity, positive predictive value and diagnostic accuracy of mammography was calculated and was found to be 94.9% , 90% , 86% and 92% respectively. The sensitivity, specificity, positive predictive value and diagnostic accuracy of

  3. Image-guided modified deep anterior lamellar keratoplasty (DALK) corneal transplant using intraoperative optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tao, Yuankai K.; LaBarbera, Michael; Ehlers, Justis P.; Srivastava, Sunil K.; Dupps, William J.

    2015-03-01

    Deep anterior lamellar keratoplasty (DALK) is an alternative to full-thickness corneal transplant and has advantages including the absence of allograft rejection; shortened duration of topical corticosteroid treatment and reduced associated risk of glaucoma, cataract, or infection; and enables use of grafts with poor endothelial quality. DALK begins by performing a trephination of approximately 80% stromal thickness, as measured by pachymetry. After removal of the anterior stoma, a needle is inserted into the residual stroma to inject air or viscoelastic to dissect Descemet's membrane. These procedures are inherently difficult and intraoperative rates of Descemet's membrane perforation between 4-39% have been reported. Optical coherence tomography (OCT) provides high-resolution images of tissue microstructures in the cornea, including Descemet's membrane, and allows quantitation of corneal layer thicknesses. Here, we use crosssectional intraoperative OCT (iOCT) measurements of corneal thickness during surgery and a novel micrometeradjustable biopsy punch to precision-cut the stroma down to Descemet's membrane. Our prototype cutting tool allows us to establish a dissection plane at the corneal endothelium interface, mitigates variability in cut-depths as a result of tremor, reduces procedure complexity, and reduces complication rates. iOCT-guided modified DALK procedures were performed on 47 cadaveric porcine eyes by non-experts and achieved a perforation rate of ~5% with a mean corneal dissection time <18 minutes. The procedure was also successful performed on a human donor eye without perforation. Our data shows the potential for iOCT-guided precision anterior segment surgery without variability as a result of tremor and improvements to standard clinical care.

  4. Descemet membrane endothelial keratoplasty in cases with existing scleral-sutured and iris-sutured intraocular lenses

    PubMed Central

    2014-01-01

    Background To report two cases of Descemet Membrane Endothelial Keratoplasty (DMEK) in patients with existing scleral-fixated and iris-fixated intraocular lenses (sf-IOL and if-IOL, respectively). Case presentation DMEK procedures were performed on a 49-year-old woman with a pre-existing sf-IOL (case 1) and a 69-year-old woman with a pre-existing if-IOL (case 2) in order to treat secondary corneal edema due to pseudophakic bullous keratopathy. Visual acuity, refractive error, intraocular pressure, slit lamp examination, pachymetry measurements and endothelial cell density (ECD) were considered and repeated during follow-ups. Both cases had no intraoperative complications. At postoperative day 1 graft centration and complete attachment were noted. The IOL positions were unchanged in comparison to their preoperative positions. In case 1, visual acuity improved from 1/15 at 1 meter preoperative to 20/200 within one week and to 20/63 within 12 weeks of follow up. In case 2, visual acuity improved from counting fingers at 1 meter preoperative to 20/200 within one week and to 20/100 within 12 weeks of follow-up. In case 2 a partial graft dislocation was observed at postoperative day twenty. Complete graft re-apposition was achieved by rebubbling procedure performed with intracameral air injection. Conclusions DMEK surgery in the treatment of pseudophakic bullous keratopathy in the presence of sf-IOL and if-IOL can successfully be performed. These eyes are at increased risk of IOL dislocation into the vitreous cavity during DMEK surgery. PMID:24443809

  5. Big-bubble deep anterior lamellar keratoplasty using central vs peripheral air injection: a clinical trial.

    PubMed

    Feizi, Sepehr; Daryabari, Seyed-Hashem; Najdi, Danial; Javadi, Mohammad Ali; Karimian, Farid

    2016-06-10

    To compare 2 sites of air injection to achieve Descemet membrane (DM) detachment in big-bubble deep anterior lamellar keratoplasty (DALK). In this prospective, randomized study, 48 eyes of 48 keratoconus-affected patients who underwent DALK by cornea fellows were enrolled. Each patient was randomly assigned into one of 2 groups. After trephination to approximately 80% of the corneal thickness, a 27-G needle was inserted into the stroma from the trephination site. The needle was moved radially inside the trephination site and advanced to the central or paracentral cornea in group 1. In group 2, the needle was inserted into the deep stroma from the trephination site and advanced into the peripheral cornea to approximately 1.5 mm anterior to the limbus. Air was gently injected into the deep stroma until a big bubble was formed. The rates of DM separation and complications were compared between the 2 groups. Big-bubble formation was successful in 79.2% of the eyes in the study group. A bare DM was achieved by central injection in 68.0% of group 1 and by peripheral injection in 69.6% of group 2 (p = 0.68). This rate was increased to 80.0% and 78.3% in groups 1 and 2, respectively, after the injection site was shifted when injections failed. The study groups were comparable in terms of complications including DM perforation and bubble bursting. Both injection sites were equivalent in their rates of big-bubble formation and complications. Less experienced surgeons are advised to initially inject air outside the trephination.

  6. The interface of mental health and human rights in Indigenous peoples: triple jeopardy and triple opportunity.

    PubMed

    Tarantola, Daniel

    2007-01-01

    Insufficient understanding of the reciprocal interactions between health and human rights, mental health and human rights and the realization of all human rights by Indigenous peoples constitute a triple jeopardy in how these topics are currently being addressed and/or openly antagonized. This paper will attempt to show how a combined health and human rights approach to mental health in Indigenous peoples can transform a triple jeopardy into a triple opportunity. The vast and growing body of literature on mental health, health as a whole, and human rights as these relate to health and to Indigenous peoples will be used to frame the discussion. Attention to the complex interactions of health and human rights can guide policy formulation and action by offering a method of analysis, a process of participatory decision and a framework for accountability. In addition, mental health can find its rightful place in the health and human rights discourse through efforts to help policymakers and practitioners broaden their vision of mental illness to holistically encompass aspects of physical, social, emotional and cultural wellbeing. Finally, connecting the role that rights realization plays in determining health and wellbeing will add power to the rightful claims by Indigenous peoples to the promotion and protection of all their human rights--civil, political, economic, social and cultural. Broadening the research agenda by applying systematically a health and human rights analytical framework to the understanding of social determinants of health would minimize the risk of assigning health outcome merely to behaviours, practices and lifestyles, uncovering structural determinants of holistic health entrenched in policies and governmental conduct. Building the evidence of the negative impact of human rights violation on health and the negative impact of ill-health on the fulfilment of other human rights can help in designing comprehensive interventions, building on the

  7. Evolution of the northern Main Ethiopian rift: birth of a triple junction

    NASA Astrophysics Data System (ADS)

    Wolfenden, Ellen; Ebinger, Cynthia; Yirgu, Gezahegn; Deino, Alan; Ayalew, Dereje

    2004-07-01

    Models for the formation of the archetypal rift-rift-rift triple junction in the Afar depression have assumed the synchronous development of the Red Sea-Aden-East African rift systems soon after flood basaltic magmatism at 31 Ma, but the timing of intial rifting in the northern sector of the East African rift system had been poorly constrained. The aims of our field, geochronology, and remote sensing studies were to determine the timing and kinematics of rifting in the 3rd arm, the Main Ethiopian rift (MER), near its intersection with the southern Red Sea rift. New structural data and 10 new SCLF 40Ar/39Ar dates show that extension in the northern Main Ethiopian rift commenced after 11 Ma, more than 17 My after initial rifting in the southern Red Sea and Gulf of Aden. The triple junction, therefore, could have developed only during the past 11 My, or 20 My after the flood basaltic magmatism. Thus, the flood basaltic magmatism and separation of Arabia from Africa are widely separated in time from the opening of the Main Ethiopian rift, which marks the incipient Nubia-Somalia plate boundary; triple junction formation is not a primary feature of breakup above the Afar mantle plume. The East African rift system appears to have propagated northward from the Mesozoic Anza rift system into the Afar depression to cut across Oligo-Miocene rift structures of the Red Sea and Gulf of Aden, in response to global plate reorganisations. Structural patterns reveal a change from 130°E-directed extension to 105°E-directed extension sometime in the interval 6.6 to 3 Ma, consistent with predictions from global plate kinematic studies. The along-axis propagation of rifting in each of the three arms of the triple junction has led to a NE-migration of the triple junction since 11 Ma.

  8. Migration of grain boundaries and triple junctions in high-purity aluminum during annealing after slight cold rolling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yin, Wenhong; School of Mechanical Engineering, Shandong University of Technology, Zibo 255049; Wang, Weiguo, E-mail: wang_weiguo@vip.163.com

    Grain orientations and grain boundary migrations near triple junctions in a high purity aluminum were analyzed by electron back scattered diffraction. The results indicate that there are good correlations between the Schmid factors or Taylor factors and the misorientation values of point to original point in grains near the triple junctions in a slightly deformed sample. Grains with higher Schmid factors or lower Taylor factors typically correspond to higher misorientation values near the triple junctions. In a subsequent annealing at 400 °C, both grain boundaries and triple junctions migrate, but the former leave ghost lines. During such migration, a grainmore » boundary grows from the grain with lower Schmid factor (higher Taylor factor) into the grain with higher Schmid factor (lower Taylor factor). Usually, the amount of migration of a grain boundary is considerably greater than that of a triple junction, and the grain boundary becomes more curved after migration. These observations indicate that the triple junctions have drag effects on grain boundary migration. - Highlights: • Polycrystalline aluminum with fine grains about 30 μm were used. • Off-line in situ EBSD was used to identify TJs before and after annealing. • Grains with higher SFs have higher misorientation values near TJs after deformation. • Grain boundaries grow from hard grains into soft grains during annealing. • Triple junctions have drag effects on grain boundaries migration.« less

  9. Guided Search for Triple Conjunctions

    PubMed Central

    Nordfang, Maria; Wolfe, Jeremy M

    2017-01-01

    A key tenet of Feature Integration Theory and related theories such as Guided Search (GS) is that the binding of basic features requires attention. This would seem to predict that conjunctions of features of objects that have not been attended should not influence search. However, Found (1998) reported that an irrelevant feature (size) improved the efficiency of search for a color × orientation conjunction if it was correlated with the other two features across the display compared to the case where size was not correlated with color and orientation features. We examine this issue with somewhat different stimuli. We use triple conjunctions of color, orientation and shape (e.g. search for a red, vertical, oval-shaped item). This allows us to manipulate the number of features that each distractor shares with the target (Sharing) and it allows us to vary the total number of distractor types (and, thus, the number of groups of identical items; Grouping). We find these triple conjunction searches are generally very efficient – producing very shallow reaction time (RT) × set size slopes, consistent with strong guidance by basic features. Nevertheless, both of these variables, Sharing and Grouping modulate performance. These influences are not predicted by previous accounts of GS. However, both can be accommodated in a GS framework. Alternatively, it is possible, if not necessary, to see these effects as evidence for “preattentive binding” of conjunctions. PMID:25005070

  10. Guided search for triple conjunctions.

    PubMed

    Nordfang, Maria; Wolfe, Jeremy M

    2014-08-01

    A key tenet of feature integration theory and of related theories such as guided search (GS) is that the binding of basic features requires attention. This would seem to predict that conjunctions of features of objects that have not been attended should not influence search. However, Found (1998) reported that an irrelevant feature (size) improved the efficiency of search for a Color × Orientation conjunction if it was correlated with the other two features across the display, as compared to the case in which size was not correlated with color and orientation features. We examined this issue with somewhat different stimuli. We used triple conjunctions of color, orientation, and shape (e.g., search for a red, vertical, oval-shaped item). This allowed us to manipulate the number of features that each distractor shared with the target (sharing) and it allowed us to vary the total number of distractor types (and, thus, the number of groups of identical items: grouping). We found that these triple conjunction searches were generally very efficient--producing very shallow Reaction Time × Set Size slopes, consistent with strong guidance by basic features. Nevertheless, both of the variables, sharing and grouping, modulated performance. These influences were not predicted by previous accounts of GS; however, both can be accommodated in a GS framework. Alternatively, it is possible, though not necessary, to see these effects as evidence for "preattentive binding" of conjunctions.

  11. Perturbative triples correction for local pair natural orbital based explicitly correlated CCSD(F12*) using Laplace transformation techniques.

    PubMed

    Schmitz, Gunnar; Hättig, Christof

    2016-12-21

    We present an implementation of pair natural orbital coupled cluster singles and doubles with perturbative triples, PNO-CCSD(T), which avoids the quasi-canonical triples approximation (T0) where couplings due to off-diagonal Fock matrix elements are neglected. A numerical Laplace transformation of the canonical expression for the perturbative (T) triples correction is used to avoid an I/O and storage bottleneck for the triples amplitudes. Results for a test set of reaction energies show that only very few Laplace grid points are needed to obtain converged energy differences and that PNO-CCSD(T) is a more robust approximation than PNO-CCSD(T0) with a reduced mean absolute deviation from canonical CCSD(T) results. We combine the PNO-based (T) triples correction with the explicitly correlated PNO-CCSD(F12*) method and investigate the use of specialized F12-PNOs in the conventional triples correction. We find that no significant additional errors are introduced and that PNO-CCSD(F12*)(T) can be applied in a black box manner.

  12. Synthesis and crystal structure analysis of uranyl triple acetates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klepov, Vladislav V., E-mail: vladislavklepov@gmail.com; Department of Chemistry, Samara National Research University, 443086 Samara; Serezhkina, Larisa B.

    2016-12-15

    Single crystals of triple acetates NaR[UO{sub 2}(CH{sub 3}COO){sub 3}]{sub 3}·6H{sub 2}O (R=Mg, Co, Ni, Zn), well-known for their use as reagents for sodium determination, were grown from aqueous solutions and their structural and spectroscopic properties were studied. Crystal structures of the mentioned phases are based upon (Na[UO{sub 2}(CH{sub 3}COO){sub 3}]{sub 3}){sup 2–} clusters and [R(H{sub 2}O){sub 6}]{sup 2+} aqua-complexes. The cooling of a single crystal of NaMg[UO{sub 2}(CH{sub 3}COO){sub 3}]{sub 3}·6H{sub 2}O from 300 to 100 K leads to a phase transition from trigonal to monoclinic crystal system. Intermolecular interactions between the structural units and their mutual packing were studiedmore » and compared from the point of view of the stereoatomic model of crystal structures based on Voronoi-Dirichlet tessellation. Using this method we compared the crystal structures of the triple acetates with Na[UO{sub 2}(CH{sub 3}COO){sub 3}] and [R(H{sub 2}O){sub 6}][UO{sub 2}(CH{sub 3}COO){sub 3}]{sub 2} and proposed reasons of triple acetates stability. Infrared and Raman spectra were collected and their bands were assigned. - Graphical abstract: Single crystals of uranium based triple acetates, analytical reagents for sodium determination, were synthesized and structurally, spectroscopically and topologically characterized. The structures were compared with the structures of compounds from preceding families [M(H{sub 2}O){sub 6})][UO{sub 2}(CH{sub 3}COO){sub 3}]{sub 2} (M = Mg, Co, Ni, Zn) and Na[UO{sub 2}(CH{sub 3}COO){sub 3}]. Analysis was performed with the method of molecular Voronoi-Dirichlet polyhedra to reveal a large contribution of the hydrogen bonds into intermolecular interactions which can be a reason of low solubility of studied complexes.« less

  13. Dually actuated triple shape memory polymers of cross-linked polycyclooctene-carbon nanotube/polyethylene nanocomposites.

    PubMed

    Wang, Zhenwen; Zhao, Jun; Chen, Min; Yang, Minhao; Tang, Luyang; Dang, Zhi-Min; Chen, Fenghua; Huang, Miaoming; Dong, Xia

    2014-11-26

    In this work, electrically and thermally actuated triple shape memory polymers (SMPs) of chemically cross-linked polycyclooctene (PCO)-multiwalled carbon nanotube (MWCNT)/polyethylene (PE) nanocomposites with co-continuous structure and selective distribution of fillers in PCO phase are prepared. We systematically studied not only the microstructure including morphology and fillers' selective distribution in one phase of the PCO/PE blends, but also the macroscopic properties including thermal, mechanical, and electrical properties. The co-continuous window of the immiscible PCO/PE blends is found to be the volume fraction of PCO (vPCO) of ca. 40-70 vol %. The selective distribution of fillers in one phase of co-continuous blends is obtained by a masterbatch technique. The prepared triple SMP materials show pronounced triple shape memory effects (SMEs) on the dynamic mechanical thermal analysis (DMTA) and the visual observation by both thermal and electric actuations. Such polyolefin samples with well-defined microstructure, electrical actuation, and triple SMEs might have potential applications as, for example, multiple autochoke elements for engines, self-adjusting orthodontic wires, and ophthalmic devices.

  14. Triple dividends of water consumption charges in South Africa

    NASA Astrophysics Data System (ADS)

    Letsoalo, Anthony; Blignaut, James; de Wet, Theuns; de Wit, Martin; Hess, Sebastiaan; Tol, Richard S. J.; van Heerden, Jan

    2007-05-01

    The South African government is exploring ways to address water scarcity problems by introducing a water resource management charge on the quantity of water used in sectors such as irrigated agriculture, mining, and forestry. It is expected that a more efficient water allocation, lower use, and a positive impact on poverty can be achieved. This paper reports on the validity of these claims by applying a computable general equilibrium model to analyze the triple dividend of water consumption charges in South Africa: reduced water use, more rapid economic growth, and a more equal income distribution. It is shown that an appropriate budget-neutral combination of water charges, particularly on irrigated agriculture and coal mining, and reduced indirect taxes, particularly on food, would yield triple dividends, that is, less water use, more growth, and less poverty.

  15. Grain boundary and triple junction diffusion in nanocrystalline copper

    NASA Astrophysics Data System (ADS)

    Wegner, M.; Leuthold, J.; Peterlechner, M.; Song, X.; Divinski, S. V.; Wilde, G.

    2014-09-01

    Grain boundary and triple junction diffusion in nanocrystalline Cu samples with grain sizes, , of ˜35 and ˜44 nm produced by spark plasma sintering were investigated by the radiotracer method using the 63Ni isotope. The measured diffusivities, Deff, are comparable with those determined previously for Ni grain boundary diffusion in well-annealed, high purity, coarse grained, polycrystalline copper, substantiating the absence of a grain size effect on the kinetic properties of grain boundaries in a nanocrystalline material at grain sizes d ≥ 35 nm. Simultaneously, the analysis predicts that if triple junction diffusion of Ni in Cu is enhanced with respect to the corresponding grain boundary diffusion rate, it is still less than 500ṡDgb within the temperature interval from 420 K to 470 K.

  16. Triple point determinations of monomethylhydrazine and nitrogen tetroxide, 2.2 percent by weight nitric oxide

    NASA Technical Reports Server (NTRS)

    Smith, Irwin D.; Dhooge, Patrick M.

    1977-01-01

    A series of tests was performed to ascertain the triple points of monomethylhydrazine and nitrogen tetroxide. A laboratory method indicated a triple point for monomethylhydrazine, but tests in a large vacuum chamber indicated that a triple point does not occur in spacelike conditions because the mono-methylhydrazine tends to supercool. Instead, an effective freezing point (with agitation) was obtained. New experimental values for liquid monomethylhydrazine vapor pressure were determined for temperatures from 275.2 to 207.6 K. The values were used to derive vapor pressure equations. Tentative values were obtained for the effective freezing point of nitrogen tetroxide spacelike conditions.

  17. How health systems could avert 'triple fail' events that are harmful, are costly, and result in poor patient satisfaction.

    PubMed

    Lewis, Geraint; Kirkham, Heather; Duncan, Ian; Vaithianathan, Rhema

    2013-04-01

    Health care systems in many countries are using the "Triple Aim"--to improve patients' experience of care, to advance population health, and to lower per capita costs--as a focus for improving quality. Population strategies for addressing the Triple Aim are becoming increasingly prevalent in developed countries, but ultimately success will also require targeting specific subgroups and individuals. Certain events, which we call "Triple Fail" events, constitute a simultaneous failure to meet all three Triple Aim goals. The risk of experiencing different Triple Fail events varies widely across people. We argue that by stratifying populations according to each person's risk and anticipated response to an intervention, health systems could more effectively target different preventive interventions at particular risk strata. In this article we describe how such an approach could be planned and operationalized. Policy makers should consider using this stratified approach to reduce the incidence of Triple Fail events, thereby improving outcomes, enhancing patient experience, and lowering costs.

  18. Characteristics of Known Triple Asteroid Systems in the Main Belt

    NASA Astrophysics Data System (ADS)

    Marchis, Franck; Berthier, J.; Burns, K. J.; Descamps, P.; Durech, J.; Emery, J. P.; Enriquez, J. E.; Lainey, V.; Reiss, A. E.; Vachier, F.

    2010-10-01

    Since the discovery of "Sylvia Remus II” [1], around the binary asteroid (87) Sylvia [2] using the VLT/NACO instrument, the number of known triple systems increased significantly. Using the same instrument, a second moonlet was discovered around the binary (45) Eugenia [3] in 2007 [4]. Using an improved W.M. Keck II AO system, [5] announced the discovery of two 3 & 5-km moons orbiting the M-type asteroid (216) Kleopatra and more recently, [6] revealed the presence of two tiny 4-km moons around the C-type (93) Minerva. 3749 Balam is a different triple asteroid system whose existence was suggested by combining lightcurves and AO observations [7]. The properties of these triple systems have been derived individually and published recently [1, 8,9,10]. We will review and contrast their characteristics, including the orbital parameters of the satellite orbits, the size and shape of the primary and the satellites, their taxonomic classes, their bulk densities, and their ages. The goal of this study is to uncover clues concerning the formation and evolution of these mini-planetary systems. The National Science Foundation supported this research under award number AAG-0807468. 1. Marchis et al. Nature 2005 2. Brown et al., IAU 7588, 2001 3. Merline et al. Nature 401, 1999 4. Marchis et al. IAU 1073, 2007 5. Marchis et al. IAU 8980, 2008 6. Marchis et al., IAU 9069, 2009 7. Marchis et al., IAU 8928, 2008 8. Marchis et al., A Dynamical Solution of the Triple Asteroid System (45) Eugenia , Icarus in press, 2010 9. Descamps et al, Triplicity and Physical Characteristics of Asteroid 216 Kleopatra Icarus, in revision, 2010 10. Marchis et al., Triplicity and Physical Characteristics of the main-belt Asteroid (93) Minerva, Icarus submitted 2010

  19. Effect of aqueous ethanol on the triple helical structure of collagen.

    PubMed

    Gopinath, Arun; Reddy, Samala Murali Mohan; Madhan, Balaraman; Shanmguam, Ganesh; Rao, Jonnalagadda Raghava

    2014-12-01

    Collagen, the most abundant protein in mammals, is widely used for making biomaterials. Recently, organic solvents have been used to fabricate collagen-based biomaterials for biological applications. It is therefore necessary to understand the behavior of collagen in the presence of organic solvents at low (≤50%, v/v) and high (≥90%, v/v) concentrations. This study was conducted to examine how collagen reacts when exposed to low and high concentrations of ethanol, one of the solvents used to make collagen-based biomaterials. Solubility testing indicated that collagen remains in solution at low concentrations (≤50%, v/v) of ethanol but precipitates (gel-like) thereafter, irrespective of the method of addition of ethanol (single shot or gradual addition); this behavior is different from that observed recently with acetonitrile. Collagen retains its triple helix in the presence of ethanol but becomes thermodynamically unstable, with substantially reduced melting temperature, with increasing concentration of ethanol. It was also found that the CD ellipticity at 222 nm, characteristic of the triple-helical structure, does not correlate with the thermal stability of collagen. Time-dependent experiments reveal that the collagen triple helix is kinetically stable in the presence of 0-40% (v/v) ethanol at low temperature (5 °C) but highly unstable in the presence of ethanol at elevated temperature (~34 °C). These results indicate that when ethanol is used to process collagen-based biomaterials, such factors as temperature and duration should be done taking into account, to prevent extensive damage to the triple-helical structure of collagen.

  20. Recent advances in (soil moisture) triple collocation analysis

    USDA-ARS?s Scientific Manuscript database

    To date, triple collocation (TC) analysis is one of the most important methods for the global scale evaluation of remotely sensed soil moisture data sets. In this study we review existing implementations of soil moisture TC analysis as well as investigations of the assumptions underlying the method....

  1. Understanding the loss-of-function in a triple missense mutant of DNA polymerase β found in prostate cancer.

    PubMed

    An, Changlong; Beard, William A; Chen, Desheng; Wilson, Samuel H; Makridakis, Nick M

    2013-10-01

    Human DNA polymerase (pol) β is essential for base excision repair. We previously reported a triple somatic mutant of pol β (p.P261L/T292A/I298T) found in an early onset prostate tumor. This mutation abolishes polymerase activity, and the wild-type allele was not present in the tumor, indicating a complete deficiency in pol β function. The effect on polymerase activity is unexpected because the point mutations that comprise the triple mutant are not part of the active site. Herein, we demonstrate the mechanism of this loss-of-function. In order to understand the effect of the individual point mutations we biochemically analyzed all single and double mutants that comprise the triple mutant. We found that the p.I298T mutation is responsible for a marked instability of the triple mutant protein at 37˚C. At room temperature the triple mutant's low efficiency is also due to a decrease in the apparent binding affinity for the dNTP substrate, which is due to the p.T292A mutation. Furthermore, the triple mutant displays lower fidelity for transversions in vitro, due to the p.T292A mutation. We conclude that distinct mutations of the triple pol β mutant are responsible for the loss of activity, lower fidelity, and instability observed in vitro.

  2. A Cobalt Supramolecular Triple-Stranded Helicate-based Discrete Molecular Cage

    PubMed Central

    Mai, Hien Duy; Kang, Philjae; Kim, Jin Kyung; Yoo, Hyojong

    2017-01-01

    We report a strategy to achieve a discrete cage molecule featuring a high level of structural hierarchy through a multiple-assembly process. A cobalt (Co) supramolecular triple-stranded helicate (Co-TSH)-based discrete molecular cage (1) is successfully synthesized and fully characterized. The solid-state structure of 1 shows that it is composed of six triple-stranded helicates interconnected by four linking cobalt species. This is an unusual example of a highly symmetric cage architecture resulting from the coordination-driven assembly of metallosupramolecular modules. The molecular cage 1 shows much higher CO2 uptake properties and selectivity compared with the separate supramolecular modules (Co-TSH, complex 2) and other molecular platforms. PMID:28262690

  3. The proteomic landscape of triple-negative breast cancer.

    PubMed

    Lawrence, Robert T; Perez, Elizabeth M; Hernández, Daniel; Miller, Chris P; Haas, Kelsey M; Irie, Hanna Y; Lee, Su-In; Blau, C Anthony; Villén, Judit

    2015-04-28

    Triple-negative breast cancer is a heterogeneous disease characterized by poor clinical outcomes and a shortage of targeted treatment options. To discover molecular features of triple-negative breast cancer, we performed quantitative proteomics analysis of twenty human-derived breast cell lines and four primary breast tumors to a depth of more than 12,000 distinct proteins. We used this data to identify breast cancer subtypes at the protein level and demonstrate the precise quantification of biomarkers, signaling proteins, and biological pathways by mass spectrometry. We integrated proteomics data with exome sequence resources to identify genomic aberrations that affect protein expression. We performed a high-throughput drug screen to identify protein markers of drug sensitivity and understand the mechanisms of drug resistance. The genome and proteome provide complementary information that, when combined, yield a powerful engine for therapeutic discovery. This resource is available to the cancer research community to catalyze further analysis and investigation. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Discovery of the triple asteroidal system 87 Sylvia.

    PubMed

    Marchis, Franck; Descamps, Pascal; Hestroffer, Daniel; Berthier, Jérome

    2005-08-11

    After decades of speculation, the existence of binary asteroids has been observationally confirmed, with examples in all minor planet populations. However, no triple systems have hitherto been discovered. Here we report the unambiguous detection of a triple asteroidal system in the main belt, composed of a 280-km primary (87 Sylvia) and two small moonlets orbiting at 710 and 1,360 km. We estimate their orbital elements and use them to refine the shape of the primary body. Both orbits are equatorial, circular and prograde, suggesting a common origin. Using the orbital information to estimate its mass and density, 87 Sylvia appears to have a rubble-pile structure with a porosity of 25-60 per cent. The system was most probably formed through the disruptive collision of a parent asteroid, with the new primary resulting from accretion of fragments, while the moonlets are formed from the debris, as has been predicted previously.

  5. Physics of lateral triple quantum-dot molecules with controlled electron numbers.

    PubMed

    Hsieh, Chang-Yu; Shim, Yun-Pil; Korkusinski, Marek; Hawrylak, Pawel

    2012-11-01

    We review the recent progress in theory and experiments with lateral triple quantum dots with controlled electron numbers down to one electron in each dot. The theory covers electronic and spin properties as a function of topology, number of electrons, gate voltage and external magnetic field. The orbital Hund's rules and Nagaoka ferromagnetism, magnetic frustration and chirality, interplay of quantum interference and electron-electron interactions and geometrical phases are described and related to charging and transport spectroscopy. Fabrication techniques and recent experiments are covered, as well as potential applications of triple quantum-dot molecule in coherent control, spin manipulation and quantum computation.

  6. Double- and Triple-Duty Caregiving Men: An Examination of Subjective Stress and Perceived Schedule Control.

    PubMed

    DePasquale, Nicole; Zarit, Steven H; Mogle, Jacqueline; Moen, Phyllis; Hammer, Leslie B; Almeida, David M

    2018-04-01

    Based on the stress process model of family caregiving, this study examined subjective stress appraisals and perceived schedule control among men employed in the long-term care industry (workplace-only caregivers) who concurrently occupied unpaid family caregiving roles for children (double-duty child caregivers), older adults (double-duty elder caregivers), and both children and older adults (triple-duty caregivers). Survey responses from 123 men working in nursing home facilities in the United States were analyzed using multiple linear regression models. Results indicated that workplace-only and double- and triple-duty caregivers' appraised primary stress similarly. However, several differences emerged with respect to secondary role strains, specifically work-family conflict, emotional exhaustion, and turnover intentions. Schedule control also constituted a stress buffer for double- and triple-duty caregivers, particularly among double-duty elder caregivers. These findings contribute to the scarce literature on double- and triple-duty caregiving men and have practical implications for recruitment and retention strategies in the health care industry.

  7. Antinociceptive interactions of triple and quadruple combinations of endogenous ligands at the spinal level.

    PubMed

    Horvath, Gyongyi; Kekesi, Gabriella; Tuboly, Gabor; Benedek, Gyorgy

    2007-06-25

    A very interesting and rapidly developing field of pain research is related to the roles of different endogenous ligands. This study determined the antinociceptive interactions of triple and quadruple combinations of different endogenous ligands (endomorphin-1, adenosine, agmatine and kynurenic acid) on carrageenan-induced inflammatory pain model at the spinal level. Intrathecal infusion (60 min) of these drugs alone, in double, triple or quadruple combinations, was followed by a 60-min observation period. During the infusion, antihyperalgesic effect of 0.3 microg/min endomorphin-1 was higher in the triple combinations than those in the double combinations. After cessation of drug administration, only the combination of 0.3 microg/min endomorphin-1, 1 microg/min agmatine, and 0.3 microg/min adenosine was more effective than the double combinations. In quadruple combinations, the antinociceptive effects of both 0.1 and 0.3 microg/min endomorphin-1 were significantly potentiated by the otherwise ineffective triple combination of adenosine, agmatine, and kynurenic acid. No side effects could be observed at these doses. These results demonstrate that triple and quadruple combinations of these endogenous ligands caused more effective antihyperalgesia compared with double combinations. Accordingly, the doses of these substances could be further reduced, thus, reinforcing the view that complex activation and/or inhibition of different systems can be sufficiently effective in blocking nociception without adverse effects. Because all of these drugs had effects on various receptors and systems, the possible types of these interactions were discussed.

  8. Determination of the Latent Heats and Triple Point of Perfluorocyclobutane

    ERIC Educational Resources Information Center

    Briggs, A. G.; Strachan, A. N.

    1977-01-01

    Proposes the use of Perfluorocyclobutane in physical chemistry courses to conduct experiments on latent heat, triple point temperatures and pressures, boiling points, and entropy of vaporization. (SL)

  9. Prenatal diagnosis and prognosis of triple X syndrome: 47, XXX.

    PubMed

    Ben Hamouda, H; Mkacher, N; Elghezal, H; Bannour, H; Kamoun, M; Soua, H; Saad, A; Souissi, M M; Sfar, M T

    2009-11-01

    Triple X syndrome is a relatively common sex chromosomal abnormality occurring in 0,1% of live-born female infants. Most of these infants have a normal phenotype and only a few cases with 47, XXX karyotype have congenital malformations. We report three cases of triple X syndrome that were diagnosed prenatally by genetic amniocentesis for advanced maternal age and have been observed from birth to age of 3 to 12 years. A description of their growth and development is presented. The birth weight was normal in all patients and one of them had facial dysmorphism with right microphtalmia and auricular septal defect. During the first 2 years of life, the neuromotor development of these infants was not distinguishable from chromosomally normal children. By 3 years of age, two patients have a moderate developmental delay in speech and language. One girl 12-year-old had normal schooling. The diagnosis of the triple X syndrome can be never made because clinical demonstrations are not rather important to arouse the demand of a karyotype. Prenatal diagnosis is often made in front of the advanced maternal age. Expectant parents must be counseled as to the significance of this 47, XXX karyotype and prognostic information must be given.

  10. Triple combination therapy and zeaxanthin for the treatment of neovascular age-related macular degeneration: an interventional comparative study and cost-effectiveness analysis.

    PubMed

    Olk, R Joseph; Peralta, Enrique; Gierhart, Dennis L; Brown, Gary C; Brown, Melissa M

    2015-01-01

    Reports of triple combination therapy for neovascular age-related macular degeneration (AMD) suggest a benefit, as do reports for zeaxanthin. An interventional comparative study was thus undertaken to evaluate the efficacy of triple combination therapy with and without zeaxanthin, as well as the economic viability of the therapies. The cases of 543 consecutive eyes of 424 patients with subfoveal choroidal neovascularization (CNV) secondary to AMD were reviewed. All eyes were treated with triple combination therapy (triple therapy) consisting of: (1) reduced-fluence photodynamic therapy with verteporfin, (2) intravitreal bevacizumab and (3) intravitreal dexamethasone. Therapy was repeated as necessary. One cohort of patients was also given supplementation with 20 mg of oral zeaxanthin (Zx) daily. The triple therapy group without Zx received a mean of 2.8 treatment cycles and 87 % of patients had stable or improved vision at 24 months. In the triple therapy group with Zx, the mean number of treatment cycles was 2.1, with 83 % of patients having stable or improved vision at 24 months. At 24 months, CNV developed in 12.5 % of fellow eyes treated with triple therapy alone; CNV developed in 6.25 % of eyes treated with triple therapy with Zx (p = 0.03). An average cost-utility analysis revealed that triple therapy was cost-effective with a cost-utility ratio of $26,574/QALY, while triple therapy with Zx was more cost-effective with an average cost-utility ratio of $19,962/QALY. The incremental cost-utility analysis assessing the addition of Zx to triple therapy disclosed Zx supplementation was very cost-effective at $5302/QALY. When it was assumed that triple therapy with Zx reduced fellow eye CNV development by 30.3 %, the incremental cost-utility dropped to (-$6332/QALY), indicating that adding Zx to triple therapy yielded greater patient value, and was also less expensive than using triple therapy alone. Triple therapy is comparatively effective and cost

  11. Corneal endothelial autocrine trophic factor VIP in a mechanism-based strategy to enhance human donor cornea preservation for transplantation.

    PubMed

    Koh, Shay-Whey Margaret

    2012-02-01

    Vasoactive intestinal peptide (VIP) and ciliary neurotrophic factor (CNTF) are identified as autocrines of human corneal endothelial (CE) cells working in concert to maintain the differentiated state and promote the survival of the corneal endothelium. From VIP gene knockdown study, endogenous VIP is shown to maintain the level of the differentiation marker, the adhesion molecule N-cadherin, CE cell size, shape, and retention, in situ in the human donor corneoscleral explants. Exogenous VIP protects the corneal endothelium against the killing effect of oxidative stress, in part by upholding ATP levels in CE cells dying of oxidative stress-induced injury, allowing them to die of an apoptotic death instead of an acute necrotic one. The switch from the acute necrosis to the programmed cell death (apoptosis) may have allowed the injured CE cell to be rescued by the VIP-upregulated pathways, including those of Bcl-2 and N-cadherin, and resulted in long-term CE cell survival. The endogenous VIP in CE cells is upregulated by CNTF, which is released by CE cells surviving the oxidative stress. The CNTF receptor (CNTFRα) is expressed in CE cells in human donor corneoscleral explant and gradually becomes lost during corneal storage. VIP treatment (10(-8) M, 37 °C, 30 min) prior to storage of freshly dissected human donor corneoscleral explants increases their CE cell CNTFRα level and responsiveness to CNTF in upregulating the gap junctional protein connexin-43 expression. VIP treatment of both fresh and preserved corneoscleral explants reduces CE damage in the corneoscleral explants and in the corneal buttons trephined from them. CE cell loss is a critical risk factor in corneal graft failure at any time in the life of the graft, which can be as late as 5-10 years after an initially successful transplant. A new procedure, Descemet's stripping automated endothelial keratoplasty (DSAEK), which is superior to the traditional full thickness transplantation in many aspects

  12. Theoretical Implications of the PSR B1620-26 Triple System and Its Planet

    NASA Astrophysics Data System (ADS)

    Ford, Eric B.; Joshi, Kriten J.; Rasio, Frederic A.; Zbarsky, Boris

    2000-01-01

    We present a new theoretical analysis of the PSR B1620-26 triple system in the globular cluster M4, based on the latest radio pulsar timing data, which now include measurements of five time derivatives of the pulse frequency. These data allow us to determine the mass and orbital parameters of the second companion completely (up to the usual unknown orbital inclination angle i2). The current best-fit parameters correspond to a second companion of planetary mass, m2sini2~=7×10-3 Msolar , in an orbit of eccentricity e2~=0.45 and semimajor axis a2~=60 AU. Using numerical scattering experiments, we study a possible formation scenario for the triple system, which involves a dynamical exchange interaction between the binary pulsar and a primordial star-planet system. The current orbital parameters of the triple are consistent with such a dynamical origin and suggest that the separation of the parent star-planet system was very large, >~50 AU. We also examine the possible origin of the anomalously high eccentricity of the inner binary pulsar. While this eccentricity could have been induced during the same dynamical interaction that created the triple, we find that it could equally well arise from long-term secular perturbation effects in the triple, combining the general relativistic precession of the inner orbit with the Newtonian gravitational perturbation of the planet. The detection of a planet in this system may be taken as evidence that large numbers of extrasolar planetary systems, not unlike those discovered recently in the solar neighborhood, also exist in old star clusters.

  13. Triple Helix Systems: An Analytical Framework for Innovation Policy and Practice in the Knowledge Society

    ERIC Educational Resources Information Center

    Ranga, Marina; Etzkowitz, Henry

    2013-01-01

    This paper introduces the concept of Triple Helix systems as an analytical construct that synthesizes the key features of university--industry--government (Triple Helix) interactions into an "innovation system" format, defined according to systems theory as a set of components, relationships and functions. Among the components of Triple…

  14. Experimental results of use of triple-energy X-ray beam with K-edge filter in multi-energy imaging

    NASA Astrophysics Data System (ADS)

    Kim, D.; Lee, S.; Jeon, P.-H.

    2016-04-01

    Multi-energy imaging is useful for contrast enhancement of lesions, quantitative analysis of specific materials and material separation in the human body. Generally, dual-energy methods are applied to discriminating two materials, but this method cannot discriminate more than two materials. Photon-counting detectors provide spectral information from polyenergetic X-rays using multiple energy bins. In this work, we developed triple-energy X-ray beams using a filter with K-edge energy and applied them experimentally. The energy spectra of triple-energy X-ray beams were assessed by using a spectrometer. The designed triple-energy X-ray beams were validated by measuring quantitative evaluations with mean energy ratio (MER), contrast variation ratio (CVR) and exposure efficiency (EE). Then, triple-energy X-ray beams were used to extract density map of three materials, iodine (I), aluminum (Al) and polymethyl methacrylate (PMMA). The results of the thickness density maps obtained with the developed triple-energy X-ray beams were compared to those acquired using the photon-counting method. As a result, it was found experimentally that the proposed triple-energy X-ray beam technique can separate the three materials as well as the photon-counting method.

  15. Orbital Analysis of Two Triple Systems in the Open Cluster NGC 2516

    NASA Astrophysics Data System (ADS)

    Veramendi, M. E.; González, J. F.

    2010-12-01

    We report the discovery of two hierarchical triple systems in the open cluster NGC 2516. Both systems are double-lined spectroscopic binaries whose center-of-mass velocity varies in a time scale of a few years. The system BDA 19 consists of an eccentric spectroscopic binary with a period of 8.7 days and a third body orbiting with a period of about 3300 days. The close pair in the triple BDA 2 has an orbital period of 11.2 days and contains a HgMn star.

  16. Binary Black Hole Mergers from Field Triples: Properties, Rates, and the Impact of Stellar Evolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonini, Fabio; Toonen, Silvia; Hamers, Adrian S.

    We consider the formation of binary black hole (BH) mergers through the evolution of field massive triple stars. In this scenario, favorable conditions for the inspiral of a BH binary are initiated by its gravitational interaction with a distant companion, rather than by a common-envelope phase invoked in standard binary evolution models. We use a code that follows self-consistently the evolution of massive triple stars, combining the secular triple dynamics (Lidov–Kozai cycles) with stellar evolution. After a BH triple is formed, its dynamical evolution is computed using either the orbit-averaged equations of motion, or a high-precision direct integrator for triplesmore » with weaker hierarchies for which the secular perturbation theory breaks down. Most BH mergers in our models are produced in the latter non-secular dynamical regime. We derive the properties of the merging binaries and compute a BH merger rate in the range (0.3–1.3) Gpc{sup −3} yr{sup −1}, or up to ≈2.5 Gpc{sup −3} yr{sup −1} if the BH orbital planes have initially random orientation. Finally, we show that BH mergers from the triple channel have significantly higher eccentricities than those formed through the evolution of massive binaries or in dense star clusters. Measured eccentricities could therefore be used to uniquely identify binary mergers formed through the evolution of triple stars. While our results suggest up to ≈10 detections per year with Advanced-LIGO, the high eccentricities could render the merging binaries harder to detect with planned space based interferometers such as LISA.« less

  17. Isolated orbital mass as the primary presentation of a triple-hit lymphoma transformed from a systemic follicular lymphoma.

    PubMed

    Zhou, Xiao Yi; Lu, Xinyan; Raparia, Kirtee; Chen, Yi-Hua

    2018-06-01

    Triple-hit lymphoma is a highly aggressive B-cell lymphoma. We report a case of triple-hit lymphoma transformed from systemic follicular lymphoma (FL) after 9-year remission and presented primarily as an isolated orbital mass without systemic symptoms or lymphadenopathy. A 58-year-old female presented with intermittent vertical binocular diplopia, left upper eyelid swelling and pain and was found to have a 2.9 cm orbital mass. Histological section revealed a CD10-positive large B-cell lymphoma, consistent with transformation of FL. Fluorescent in situ hybridization (FISH) analysis demonstrated rearrangements involving C-MYC, BCL-2 and BCL-6 genes, indicating a high grade, triple-hit lymphoma. Triple-hit lymphoma transformed from a low-grade lymphoma may initially present as an isolated orbital mass without systemic evidence of transformation. Early recognition of double or triple-hit lymphomas is important since these patients require aggressive chemotherapy.

  18. Triple collinear emissions in parton showers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Höche, Stefan; Prestel, Stefan

    2017-10-01

    A framework to include triple collinear splitting functions into parton showers is presented, and the implementation of flavor-changing NLO splitting kernels is discussed as a first application. The correspondence between the Monte-Carlo integration and the analytic computation of NLO DGLAP evolution kernels is made explicit for both timelike and spacelike parton evolution. Numerical simulation results are obtained with two independent implementations of the new algorithm, using the two independent event generation frameworks Pythia and Sherpa.

  19. Establishment of a New National Reference Ensemble of Water Triple Point Cells

    NASA Astrophysics Data System (ADS)

    Senn, Remo

    2017-10-01

    The results of the Bilateral Comparison EURAMET.T-K3.5 (w/VSL, The Netherlands) with the goal to link Switzerland's ITS-90 realization (Ar to Al) to the latest key comparisons gave strong indications for a discrepancy in the realization of the triple point of water. Due to the age of the cells of about twenty years, it was decided to replace the complete reference ensemble with new "state-of-the-art" cells. Three new water triple point cells from three different suppliers were purchased, as well as a new maintenance bath for an additional improvement of the realization. In several loops measurements were taken, each cell of both ensembles intercompared, and the deviations and characteristics determined. The measurements show a significant lower average value of the old ensemble of 0.59 ± 0.25 mK (k=2) in comparison with the new one. Likewise, the behavior of the old cells is very unstable with a drift downward during the realization of the triple point. Based on these results the impact of the new ensemble on the ITS-90 realization from Ar to Al was calculated and set in the context to performed calibrations and their related uncertainties in the past. This paper presents the instrumentation, cells, measurement procedure, results, uncertainties and impact of the new national reference ensemble of water triple point cells on the current ITS-90 realization in Switzerland.

  20. Organ culture storage of pre-prepared corneal donor material for Descemet's membrane endothelial keratoplasty.

    PubMed

    Bhogal, Maninder; Matter, Karl; Balda, Maria S; Allan, Bruce D

    2016-11-01

    To evaluate the effect of media composition and storage method on pre-prepared Descemet's membrane endothelial keratoplasty (DMEK) grafts. 50 corneas were used. Endothelial wound healing and proliferation in different media were assessed using a standard injury model. DMEK grafts were stored using three methods: peeling with free scroll storage; partial peeling with storage on the stroma and fluid bubble separation with storage on the stroma. Endothelial cell (EC) phenotype and the extent of endothelial overgrowth were examined. Global cell viability was assessed for storage methods that maintained a normal cell phenotype. 1 mm wounds healed within 4 days. Enhanced media did not increase EC proliferation but may have increased EC migration into the wounded area. Grafts that had been trephined showed evidence of EC overgrowth, whereas preservation of a physical barrier in the bubble group prevented this. In grafts stored in enhanced media or reapposed to the stroma after trephination, endothelial migration occurred sooner and cells underwent endothelial-mesenchymal transformation. Ongoing cell loss, with new patterns of cell death, was observed after returning grafts to storage. Grafts stored as free scrolls retained more viable ECs than grafts prepared with the fluid bubble method (74.2± 3% vs 60.3±6%, p=0.04 (n=8). Free scroll storage is superior to liquid bubble and partial peeling techniques. Free scrolls only showed overgrowth of ECs after 4 days in organ culture, indicating a viable time window for the clinical use of pre-prepared DMEK donor material using this method. Methods for tissue preparation and storage media developed for whole corneas should not be used in pre-prepared DMEK grafts without prior evaluation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Organ culture storage of pre-prepared corneal donor material for Descemet's membrane endothelial keratoplasty

    PubMed Central

    Bhogal, Maninder; Matter, Karl; Balda, Maria S; Allan, Bruce D

    2016-01-01

    Purpose To evaluate the effect of media composition and storage method on pre-prepared Descemet's membrane endothelial keratoplasty (DMEK) grafts. Methods 50 corneas were used. Endothelial wound healing and proliferation in different media were assessed using a standard injury model. DMEK grafts were stored using three methods: peeling with free scroll storage; partial peeling with storage on the stroma and fluid bubble separation with storage on the stroma. Endothelial cell (EC) phenotype and the extent of endothelial overgrowth were examined. Global cell viability was assessed for storage methods that maintained a normal cell phenotype. Results 1 mm wounds healed within 4 days. Enhanced media did not increase EC proliferation but may have increased EC migration into the wounded area. Grafts that had been trephined showed evidence of EC overgrowth, whereas preservation of a physical barrier in the bubble group prevented this. In grafts stored in enhanced media or reapposed to the stroma after trephination, endothelial migration occurred sooner and cells underwent endothelial-mesenchymal transformation. Ongoing cell loss, with new patterns of cell death, was observed after returning grafts to storage. Grafts stored as free scrolls retained more viable ECs than grafts prepared with the fluid bubble method (74.2± 3% vs 60.3±6%, p=0.04 (n=8). Conclusion Free scroll storage is superior to liquid bubble and partial peeling techniques. Free scrolls only showed overgrowth of ECs after 4 days in organ culture, indicating a viable time window for the clinical use of pre-prepared DMEK donor material using this method. Methods for tissue preparation and storage media developed for whole corneas should not be used in pre-prepared DMEK grafts without prior evaluation. PMID:27543290

  2. Office-based Relaxing Incision Procedure for Correction of Astigmatism after Deep Anterior Lamellar Keratoplasty

    PubMed Central

    Javadi, Mohammad Ali; Feizi, Sepehr; Mirbabaee, Firooz; Fekri, Yousef

    2017-01-01

    Purpose: To report the outcomes of a simple and effective office-based procedure for the correction of astigmatism after deep anterior lamellar keratoplasty (DALK). Methods: This study enrolled 24 consecutive keratoconic eyes that developed an intolerable amount of graft astigmatism after DALK. The location and extension of steep semi-meridians were determined using corneal topography. Office-based relaxing incision procedures were performed at the slit-lamp biomicroscope using a 27-gauge needle. Relaxing incisions were made at the donor-recipient interface on one side of the steepest meridian with an arc length of 45° to 60° and an initial depth of approximately 70–80% of the corneal thickness. Topography was performed after 30–40 minutes and the initial incision was enhanced in depth and length. If an acceptable amount of astigmatism was not achieved, another incision was created at the opposite semi-meridian during the same session. Results: Mean follow-up period was 13.1 ± 7.4 months. Mean preoperative best spectacle corrected visual acuity was 0.26 ± 0.14 logMAR, increasing to 0.22 ± 0.09 logMAR after the procedure (P = 0.20). Mean spherical equivalent refractive error increased from − 4.64 ± 3.06 diopters (D) preoperatively to −6.06 ± 3.15 D postoperatively (P = 0.01). Mean keratometric astigmatism was reduced by 2.95 ± 3.43 D and 5.16 ± 2.97 D measured using subtraction and vector analysis methods, respectively (P < 0.001). Microperforation occurred in one eye, which spontaneously improved with no sequelae. Conclusion: Office-based relaxing incision is a safe and effective procedure for the treatment of corneal graft astigmatism after DALK. This approach effectively decreases the need for the more costly alternative in the operating room. PMID:28540006

  3. Beveled Femtosecond Laser Astigmatic Keratotomy for the Treatment of High Astigmatism Post–Penetrating Keratoplasty

    PubMed Central

    Cleary, Catherine; Tang, Maolong; Ahmed, Habeeb; Fox, Martin; Huang, David

    2013-01-01

    Purpose To use beveled femtosecond laser astigmatic keratotomy (FLAK) incisions to treat high astigmatism after penetrating keratoplasty. Methods Paired FLAK incisions at a bevel angle of 135 degrees, 65% to 75% depth, and arc lengths of 60 to 90 degrees were performed using a femtosecond laser. One case of perpendicular FLAK was presented for comparison. Vector analysis was used to calculate the changes in astigmatism. Fourier domain optical coherence tomography was used to examine incision morphology. Results Wound gaping requiring suturing was observed in the case of perpendicular FLAK. Six consecutive cases of beveled FLAK were analyzed. Fourier domain optical coherence tomography showed that beveled FLAK caused a mean forward shift of Bowman layer anterior to the incisions of 126 ± 38 μm, with no wound gaping. The mean magnitude of preoperative keratometric astigmatism was 9.8 ± 2.9 diopters (D), and postoperatively it was 4.5 ± 3.2 D (P < 0.05). Uncorrected visual acuity improved from 1.24 ± 0.13 logarithm of the minimum angle of resolution preoperatively to 0.76 ± 0.38 postoperatively (P < 0.05). Best spectacle–corrected visual acuity improved from 0.43 ± 0.33 logarithm of the minimum angle of resolution preoperatively to 0.27 ± 0.24 postoperatively (P = 0.22). Visual results were reduced in 2 patients by cataract progression. Between 1 and 3 months after beveled FLAK, the keratometric cylinder was stable (<1 D change) in 5 of 6 patients, and regressed in 1 patient. No complications occurred. Conclusions Beveled FLAK incisions at varied depth are effective in the management of postkeratoplasty astigmatism. Early postoperative changes stabilized within 1 month in most patients. Further studies are needed to assess long-term outcomes. PMID:22968362

  4. Quadrupolar, Triple [Delta]-Function Potential in One Dimension

    ERIC Educational Resources Information Center

    Patil, S. H.

    2009-01-01

    The energy and parity eigenstates for quadrupolar, triple [delta]-function potential are analysed. Using the analytical solutions in specific domains, simple expressions are obtained for even- and odd-parity bound-state energies. The Heisenberg uncertainty product is observed to have a minimum for a specific strength of the potential. The…

  5. Triple-layered polyurethane prosthesis with wrinkles for repairing partial tracheal defects.

    PubMed

    Lee, Ja H; Park, Hae S; Oh, Se H; Lee, Jin H; Kim, Jin R; Kim, Hyun J; Jung, Soo Y; Chung, Sung M; Choi, Hong S; Kim, Han S

    2014-12-01

    The purpose of this study was to develop a triple-layered artificial polyurethane (PU) scaffold with a wrinkled layer for reconstruction of partial tracheal defects. Animal experiment. PU/Pluronic F127 solution was transformed into an asymmetrically porous PU membrane by an immersion precipitation method. The nonporous wrinkled film was prepared by a simple casting of the PU solution on a grooved mold. The triple-layered wrinkled PU scaffolds were fabricated by simple inosculating between the wrinkled film and the porous membranes as in a sandwich (porous/wrinkled/porous structure). Scaffolds were transplanted into 10 New Zealand rabbits after creating tracheal windows. Endoscopic and histological examinations and mechanical tests were performed. The thickness and outer pore size of the prepared triple-layered PU scaffold were ∼1.95 mm and ∼200 μm, respectively. The wrinkled PU scaffold showed better maximum flexural strength compared to the nonwrinkled scaffold (1.03 ± 0.19 vs. 0.56 ± 0.09 MPa). Eight of 10 rabbits survived through all of the examinations and procedures. Endoscopic findings revealed that respiratory mucosa was observed over the scaffold at 3 weeks, and it was an entirely covered scaffold at 6 weeks. The circular framework of the tracheal lumen was maintained in seven of 10 rabbits. Histologic findings showed that ciliated respiratory mucosa covered the surface of the scaffolds. The tensile strength of the scaffold-implanted trachea was lower than that of the normal control. A wrinkled, triple-layered PU scaffold can be used as a ready-made scaffold for reconstruction of partial tracheal defects. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Northwest corner, showing arcade at ground level, and triple leaded ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Northwest corner, showing arcade at ground level, and triple leaded glass windows of bender room high on north elevation. - Stanford University Library, Stanford University, Palo Alto, Santa Clara County, CA

  7. Erratum to: An Analysis of Training, Generalization, and Maintenance Effects of Primary Care Triple P for Parents of Preschool-Aged Children with Disruptive Behavior.

    PubMed

    Boyle, Cynthia L; Sanders, Matthew R; Lutzker, John R; Prinz, Ronald J; Shapiro, Cheri; Whitaker, Daniel J

    2015-10-01

    The Triple P-Positive Parenting Program is owned by the University of Queensland (UQ). The University through its main technology transfer company UniQuest Pty Limited has licensed Triple P International Pty Ltd to disseminate the program worldwide. Royalties stemming from this dissemination activity are distributed to the Parenting and Family Support Centre, School of Psychology, UQ; Faculty of Health and Behavioural Sciences at UQ; and contributory authors. No author has any share or ownership in Triple P International Pty Ltd. Matthew Sanders is the founder and an author on various Triple P programs and a consultant to Triple P International. Karen Turner is an author of various Triple P programs. Ronald Prinz is a consultant to Triple P International. Cheri Shapiro is a consultant to Triple P America.

  8. Photodissociation of methyl formate: Conical intersections, roaming and triple fragmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, King-Chuen; Tsai, Po-Yu; Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 106, Taiwan

    2015-12-31

    The photodissociation channels of methyl formate have been extensively investigated by two different advanced experimental techniques, ion imaging and Fourier-Transform-Infrared emission spectroscopy, combined with quantum chemical calculations and molecular dynamics simulations. Our aim is to characterize the role of alternative routes to the conventional transition-state mediated pathway: the roaming and the triple fragmentation processes. The photolysis experiments, carried out at a range of laser wavelengths in the vicinity of the triple fragmentation threshold, beside the simulation of large bunches of classical trajectories with different initial conditions, have shown that both mechanisms share a common path that involves a conical intersectionmore » during the relaxation process from the electronic excited state S{sub 1} to the ground state S{sub 0}.« less

  9. Evaluation of assumptions in soil moisture triple collocation analysis

    USDA-ARS?s Scientific Manuscript database

    Triple collocation analysis (TCA) enables estimation of error variances for three or more products that retrieve or estimate the same geophysical variable using mutually-independent methods. Several statistical assumptions regarding the statistical nature of errors (e.g., mutual independence and ort...

  10. Compositional limits and analogs of monoclinic triple-chain silicates

    NASA Astrophysics Data System (ADS)

    Jenkins, David M.; Gilleaudeau, Geoffrey J.; Kawa, Cynthia; Dibiase, Jaclyn M.; Fokin, Maria

    2012-08-01

    Growing recognition of triple-chain silicates in nature has prompted experimental research into the conditions under which they can form and the extent of solid solution that is feasible for some key chemical substitutions. Experiments were done primarily in the range of 0.1-0.5 GPa and 200-850 °C for durations of 18-1,034 h. A wide range of bulk compositions were explored in this study that can be classified broadly into two groups: those that are Na free and involve various possible chemical substitutions into jimthompsonite (Mg10Si12O32(OH)4), and those that are Na bearing and involve chemical substitutions into the ideal end-member Na4Mg8Si12O32(OH)4. Numerous attempts to synthesize jimthompsonite or clinojimthompsonite were unsuccessful despite the type of starting material used (reagent oxides, magnesite + SiO2, talc + enstatite, or anthophyllite). Similarly, the chemical substitutions of F- for OH-, Mn2+, Ca2+, or Fe2+ for Mg2+, and 2Li+ for Mg2+ and a vacancy were unsuccessful at nucleating triple-chain silicates. Conversely, nearly pure yields of monoclinic triple-chain silicate could be made at temperatures of 440-630 °C and 0.2 GPa from the composition Na4Mg8Si12O32(OH)4, as found in previous studies, though its composition is most likely depleted in Na as evidenced by electron microprobe and FTIR analysis. Pure yields of triple-chain silicate were also obtained for the F-analog composition Na4Mg8Si12O32F4 at 550-750 °C and 0.2-0.5 GPa if a flux consisting of Na-halide salt and water in a 2:1 ratio by weight was used. In addition, limited chemical substitution could be documented for the substitutions of 2 Na+ for Na+ + H+ and of Mg2+ + vacancy for 2Na+. For the former, the Na content appears to be limited to 2.5 cations giving the ideal composition of Na2.5Mg8Si12O30.5(OH)5.5, while for the latter substitution the Na content may go as low as 1.1 cations giving the composition Na1.1Mg9.4Si12O31.9(OH)4.1 based on a fixed number of Si cations. Further

  11. Risk of abnormal triple screen for Down syndrome is significantly higher in patients with female fetuses.

    PubMed

    Spong, C Y; Ghidini, A; Stanley-Christian, H; Meck, J M; Seydel, F D; Pezzullo, J C

    1999-04-01

    Previous studies have shown that mid-trimester maternal serum alpha-fetoprotein (AFP) levels are significantly higher and human chorionic gonadotrophin (hCG) levels significantly lower in women with male compared with female fetuses. We have evaluated whether triple-screen criteria are more likely to identify women with female fetuses as at risk for Down syndrome. From the Georgetown University genetics database we obtained the absolute values and corresponding multiples of the median (MoM) for AFP, hCG and unconjugated oestriol (uE3) in singleton gestations for the period database November 1992 July 1996. A Down syndrome risk of 1/270 or greater at mid-trimester was considered as high risk. A total of 977 patients with triple screen and outcome information were identified, including 502 female and 475 male fetuses. Patients with female fetuses were significantly more likely to have lower serum AFP (p=0.003) and a positive triple screen for Down syndrome (72 (14 per cent) versus 45 (9 per cent), p<0.02) than those with male fetuses. The gestational age at triple screen, maternal serum hCG and uE3, race and diabetes were not significantly different between the two groups. Since Down syndrome is less common in female than male fetuses, and the rates of female and male Down syndrome fetuses detected by triple screen and subsequent amniocentesis are not significantly different, the excess of positive mid-trimester maternal serum triple screen in women with female fetuses is likely due to false-positive results.

  12. Outcomes of Same-Size Host and Donor Trephine in Deep Anterior Lamellar Keratoplasty for Keratoconus.

    PubMed

    Huang, Ting; Ouyang, Chen; Hou, Chao; Wu, Qianni; Hu, Yunwei

    2016-06-01

    To evaluate the efficacy of the same-size host and donor trephine on reducing myopic refractive errors for patients with keratoconus when deep anterior lamellar keratoplasty (DALK) was used. Randomized controlled clinical trial. One hundred eighteen eyes of 118 patients with keratoconus were enrolled. Using stratified blocked randomization, eligible eyes were allocated into the same-size trephine group or oversize trephine group. Postoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), spherical equivalent (SE), topography data, and eye axial length were compared at each year for 5 years. The same-size trephine group had comparable UCVA to the oversize trephine group through 5 years after surgery. But the former had better BSCVA than the latter after 3 years of follow-up. At 5 years, mean BSCVA was 0.17 ± 0.10 logMAR in the same-size trephine group vs 0.25 ± 0.13 logMAR in the oversize trephine group (P = .03). The same-size trephine group had lower topographic power than the oversize trephine group after 3 years of follow-up. At 5 years, mean topographic power was 45.30 ± 2.28 diopters (D) in the same-size trephine group vs 46.75 ± 2.60 D in the oversize trephine group (P = .006). Eye axial lengths at 5 years were longer than those preoperatively as well as at 1 year follow-up after surgery in both groups. The same-size host and donor trephine could reduce late-stage myopic refractive errors for the patients with keratoconus after DALK. The mechanism may be late-stage axial length increase with time. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Air Versus Sulfur Hexafluoride Gas Tamponade in Descemet Membrane Endothelial Keratoplasty: A Fellow Eye Comparison.

    PubMed

    von Marchtaler, Philipp V; Weller, Julia M; Kruse, Friedrich E; Tourtas, Theofilos

    2018-01-01

    To perform a fellow eye comparison of outcomes and complications when using air or sulfur hexafluoride (SF6) gas as a tamponade in Descemet membrane endothelial keratoplasty (DMEK). One hundred thirty-six eyes of 68 consecutive patients who underwent uneventful DMEK in both eyes for Fuchs endothelial corneal dystrophy were included in this retrospective study. Inclusion criteria were air tamponade (80% of the anterior chamber volume) in the first eye and 20% SF6 gas tamponade (80% of the anterior chamber volume) in the second eye; and same donor tissue culture condition in both eyes. All eyes received laser iridotomy on the day before DMEK. Main outcome measures included preoperative and postoperative best-corrected visual acuity, endothelial cell density, corneal volume, rebubbling rate, and rate of postoperative pupillary block caused by the air/gas bubble. Thirteen of 68 eyes (19.1%) with an air tamponade needed rebubbling compared with 4 of 68 eyes (5.9%) with an SF6 gas tamponade (P = 0.036). Postoperative pupillary block necessitating partial release of air/gas occurred in 1 eye (1.5%) with an air tamponade and 3 eyes (4.4%) with an SF6 gas tamponade (P = 0.301). There were no significant differences in preoperative and postoperative best-corrected visual acuity, endothelial cell density, and corneal volume within 3-month follow-up. Our results confirm the previously reported better graft adhesion when using an SF6 gas tamponade in DMEK without increased endothelial cell toxicity. The rate of pupillary block in eyes with an SF6 gas tamponade was comparable to that with an air tamponade. As a consequence, we recommend using SF6 gas as the tamponade in DMEK.

  14. Standardization of the Descemet membrane endothelial keratoplasty technique: Outcomes of the first 450 consecutive cases.

    PubMed

    Satué, M; Rodríguez-Calvo-de-Mora, M; Naveiras, M; Cabrerizo, J; Dapena, I; Melles, G R J

    2015-08-01

    To evaluate the clinical outcome of the first 450 consecutive cases after Descemet membrane endothelial keratoplasty (DMEK), as well as the effect of standardization of the technique. Comparison between 3 groups: Group I: (cases 1-125), as the extended learning curve; Group II: (cases 126-250), transition to technique standardization; Group III: (cases 251-450), surgery with standardized technique. Best corrected visual acuity, endothelial cell density, pachymetry and intra- and postoperative complications were evaluated before, and 1, 3 and 6 months after DMEK. At 6 months after surgery, 79% of eyes reached a best corrected visual acuity of≥0.8 and 43%≥1.0. Mean preoperative endothelial cell density was 2,530±220 cells/mm2 and 1,613±495 at 6 months after surgery. Mean pachymetry measured 668±92 μm and 526±46 μm pre- and (6 months) postoperatively, respectively. There were no significant differences in best corrected visual acuity, endothelial cell density and pachymetry between the 3 groups (P > .05). Graft detachment presented in 17.3% of the eyes. The detachment rate declined from 24% to 12%, and the rate of secondary surgeries from 9.6% to 3.5%, from group I to III respectively. Visual outcomes and endothelial cell density after DMEK are independent of the technique standardization. However, technique standardization may have contributed to a lower graft detachment rate and a relatively low number of secondary interventions required. As such, DMEK may become the first choice of treatment in corneal endothelial disease. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  15. The New Zealand National Eye Bank: survival and visual outcome 1 year after penetrating keratoplasty.

    PubMed

    Patel, Hussain Y; Ormonde, Sue; Brookes, Nigel H; Moffatt, S Louise; Sherwin, Trevor; Pendergrast, David G C; McGhee, Charles N J

    2011-07-01

    To identify potential donor, recipient, surgical, and postoperative factors that may influence survival and visual outcome of penetrating keratoplasty (PKP). As part of a prospective longitudinal study, the electronic records of the New Zealand National Eye Bank were analyzed for the 10-year period from 1994-2003. Both univariate and multivariate analysis was performed. During the study period, the New Zealand National Eye Bank supplied 1820 corneas for PKP and 1629 (90%) had 1-year follow-up data. Overall, the 1-year survival rate was 87% (n = 1429). Donor factors including age, donor source, cause of death, death-to-preservation interval, endothelial cell density, donor lens status, and storage duration, were not significantly associated with decreased survival. The leading cause of PKP failure was irreversible rejection (7%, n = 114). Independent risk factors identified for decreased PKP survival were: 1 or more episodes of reversible rejection, active inflammation at PKP, preexisting corneal vascularization, intraoperative complications, small graft size (≤ 7.25 mm), large graft size (≥ 8.5 mm), preoperative glaucoma, and a preoperative diagnosis of regraft or trauma. A best-corrected Snellen visual acuity of 6/12 or better was achieved in 60% of eyes [mean: 6/15 (logarithm of the minimum angle of resolution 0.40)]. Keratoconus and Fuchs endothelial dystrophy were the diagnoses with best survival and visual outcome, whereas, bullous keratopathy, trauma or noninfective keratitis were associated with poorer visual outcome. Several independent risk factors were identified that significantly influenced PKP first year survival outcome. This information is valuable to patients and surgeons with respect to determining prognosis and clinical decision making.

  16. Residential Density: The Effects of Tripling College Students

    ERIC Educational Resources Information Center

    Clark, Elizabeth A.; Jackson, Shannon; Everhart, Deborah

    2012-01-01

    Due to a greater number of students enrolling in higher educational institutions, an increase in demand for housing on college campuses exists putting a strain on infrastructure. In order to accommodate the students, some universities are tripling students in residential settings by putting three students in a room originally designed for two.…

  17. Ionic polymer-metal composite actuators based on triple-layered polyelectrolytes composed of individually functionalized layers.

    PubMed

    Lee, Jang-Woo; Yoo, Young-Tai; Lee, Jae Yeol

    2014-01-22

    Ionic polymer-metal composite (IPMC) actuators based on two types of triple-layered Nafion composite membranes were prepared via consecutive solution recasting and electroless plating methods. The triple-layered membranes are composed of a Nafion layer containing an amphiphilic organic molecule (10-camphorsulfonic acid; CSA) in the middle section (for fast and large ion conduction) and two Nafion/modified inorganic composite layers in the outer sections (for large accumulation/retention of mobile ions). For construction of the two types of IPMCs, sulfonated montmorillonite (MMT) and polypyrrole (PPy)-coated alumina fillers were incorporated into the outer layers. Both the triple-layered IPMCs exhibited 42% higher tip displacements at the maximum deflections with a negligible back-relaxation, 50-74% higher blocking forces, and more rapid responses under 3 V dc, compared with conventional single-layered Nafion-IPMCs. Improvements in cyclic displacement under a rectangular voltage input of 3 V at 1 Hz were also made in the triple-layered configurations. Compared with single-layered IPMCs consisting of the identical compositions with the respective outer composite layers, the bending rates and energy efficiencies of both the triple-layered IPMCs were significantly higher, although the blocking forces were a bit lower. These remarkable improvements were attributed to higher capacitances and Young's moduli as well as a more efficient transport of mobile ions and water through the middle layer (Nafion/CSA) and a larger accumulation/retention of the mobile species in the outer functionalized inorganic composite layers. Especially, the triple-layered IPMC with the PPy-modified alumina registered the best actuation performance among all the samples, including a viable actuation even at a low voltage of 1.5 V due to involving efficient redox reactions of PPy with the aid of hygroscopic alumina.

  18. Direct-acting antiviral-based triple therapy on alpha-fetoprotein level in chronic hepatitis C patients

    PubMed Central

    Takayama, Koji; Furusyo, Norihiro; Ogawa, Eiichi; Ikezaki, Hiroaki; Shimizu, Motohiro; Murata, Masayuki; Hayashi, Jun

    2015-01-01

    AIM: To investigate the impact of telaprevir-based triple therapy on the serum alpha-fetoprotein (AFP) level of chronic hepatitis C patients. METHODS: A total of 210 patients with chronic hepatitis C genotype 1 of high viral load (baseline serum hepatitis C virus RNA > 5.0 log10 IU/mL) were divided into two groups by type of treatment: triple therapy with telaprevir, pegylated-interferon-α (PEG-IFNα), and ribavirin (RBV) for 24 wk (n = 88), or dual therapy with PEG-IFNα and RBV for 48 wk (n = 122). The relationship between virological response and the change in the serum AFP level from baseline to 24 wk after the end of treatment was examined. RESULTS: No significant difference in mean baseline AFP level was found between the triple and dual therapy groups (8.8 ng/mL vs 7.8 ng/mL). Triple therapy produced significant declines in the AFP level in sustained virological response (SVR) and non-SVR patients (7.8 ng/mL at baseline to 3.5 ng/mL at 24 wk after the end of treatment, P < 0.001 and 14.3 ng/mL to 9.5 ng/mL, P = 0.004, respectively). In contrast, dual therapy resulted in a significant decline in AFP level only in SVR patients (4.7 ng/mL to 2.8 ng/mL, P < 0.001), but not in non-SVR patients (10.2 ng/mL to 10.1 ng/mL). Among patients with a high-baseline AFP level (≥ 10 ng/mL), the decline in the AFP level was significantly higher in the triple therapy than in the dual therapy group (15.9 ng/mL vs 1.6 ng/mL, P = 0.037). CONCLUSION: Regardless of virological response, telaprevir-based triple therapy reduced the serum AFP level. PMID:25914481

  19. Direct-acting antiviral-based triple therapy on alpha-fetoprotein level in chronic hepatitis C patients.

    PubMed

    Takayama, Koji; Furusyo, Norihiro; Ogawa, Eiichi; Ikezaki, Hiroaki; Shimizu, Motohiro; Murata, Masayuki; Hayashi, Jun

    2015-04-21

    To investigate the impact of telaprevir-based triple therapy on the serum alpha-fetoprotein (AFP) level of chronic hepatitis C patients. A total of 210 patients with chronic hepatitis C genotype 1 of high viral load (baseline serum hepatitis C virus RNA > 5.0 log10 IU/mL) were divided into two groups by type of treatment: triple therapy with telaprevir, pegylated-interferon-α (PEG-IFNα), and ribavirin (RBV) for 24 wk (n = 88), or dual therapy with PEG-IFNα and RBV for 48 wk (n = 122). The relationship between virological response and the change in the serum AFP level from baseline to 24 wk after the end of treatment was examined. No significant difference in mean baseline AFP level was found between the triple and dual therapy groups (8.8 ng/mL vs 7.8 ng/mL). Triple therapy produced significant declines in the AFP level in sustained virological response (SVR) and non-SVR patients (7.8 ng/mL at baseline to 3.5 ng/mL at 24 wk after the end of treatment, P < 0.001 and 14.3 ng/mL to 9.5 ng/mL, P = 0.004, respectively). In contrast, dual therapy resulted in a significant decline in AFP level only in SVR patients (4.7 ng/mL to 2.8 ng/mL, P < 0.001), but not in non-SVR patients (10.2 ng/mL to 10.1 ng/mL). Among patients with a high-baseline AFP level (≥ 10 ng/mL), the decline in the AFP level was significantly higher in the triple therapy than in the dual therapy group (15.9 ng/mL vs 1.6 ng/mL, P = 0.037). Regardless of virological response, telaprevir-based triple therapy reduced the serum AFP level.

  20. Triple collinear emissions in parton showers

    DOE PAGES

    Hoche, Stefan; Prestel, Stefan

    2017-10-17

    A framework to include triple collinear splitting functions into parton showers is presented, and the implementation of flavor-changing next-to-leading-order (NLO) splitting kernels is discussed as a first application. The correspondence between the Monte Carlo integration and the analytic computation of NLO DGLAP evolution kernels is made explicit for both timelike and spacelike parton evolution. Finally, numerical simulation results are obtained with two independent implementations of the new algorithm, using the two independent event generation frameworks PYTHIA and SHERPA.