Sample records for kerosene-fired space heaters

  1. Kerosene space heaters--combustion technology and kerosene characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubayashi, k.; I Wasaki, N.

    1984-07-01

    This paper describes kerosene combustion technology. Unvented wick-type kerosene space heaters are very popular in Japan because of their economy and convenience. In recent years new vaporized kerosene burners having premixed combustion systems have been developed to solve some of the problems encountered in the older portable type. Some of the features of the new burners are instantaneous ignition, no vaporizing deposit on the burner and a wide range heating capacity. These new kerosene heaters have four major components: an air supply fan, a fuel supply assembly, a burner assembly and a control assembly. These heaters are designed to bemore » highly reliable, have stable combustion characteristics, yield minimum carbon deposit. Finally, they are simple and inexpensive to operate.« less

  2. TOTAL PARTICLE, SULFATE, AND ACIDIC AEROSOL EMISSIONS FROM KEROSENE SPACE HEATERS

    EPA Science Inventory

    Chamber studies were conducted on four unvented kerosene space heaters to assess emissions of total particle, sulfate, and acidic aerosol. The heaters tested represented four burner designs currently in use by the public. Kerosene space heaters are a potential source of fine part...

  3. Impact of kerosene space heaters on indoor air quality.

    PubMed

    Hanoune, B; Carteret, M

    2015-09-01

    In recent years, the use of kerosene space heaters as additional or principal heat source has been increasing, because these heaters allow a continuous control on the energy cost. These devices are unvented, and all combustion products are released into the room where the heaters are operated. The indoor air quality of seven private homes using wick-type or electronic injection-type kerosene space heaters was investigated. Concentrations of CO, CO2, NOx, formaldehyde and particulate matter (0.02-10 μm) were measured, using time-resolved instruments when available. All heaters tested are significant sources of submicron particles, NOx and CO2. The average NO2 and CO2 concentrations are determined by the duration of use of the kerosene heaters. These results stress the need to regulate the use of unvented combustion appliances to decrease the exposure of people to air contaminants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Toxic organic pollutants from kerosene space heaters in Iran.

    PubMed

    Keyanpour-Rad, Mansoor

    2004-03-01

    The aim of this study was to investigate qualitatively the emission of toxic organic pollutants from an unventilated conventional kerosene space heater commonly used in Iran. A brand new common convective kerosene space heater, the "Aladdin," was used for this study. The well-tuned convective heater was operated in a 2.6-m(3) test chamber and then the emission was tested for organic pollutants. The emission was collected on Teflon-impregnated glass-fiber filters and XAD-2 resin and then analyzed by gas chromatography-mass spectroscopy. It was found that in addition to the ordinary pollutant gases, the heater emits aliphatic hydrocarbons, alcohols, polyaromatic hydrocarbons and the related nitrated compounds, phthalates, naphthalenes, and some other toxic organic compounds. However, it was found that the heater did not emit fluoranthene, cyclohexane, benzoic acid, and higher-molecular-weight alkylbenzenes, which could have resulted from the combustion of some other types of kerosene.

  5. Total particle, sulfate, and acidic aerosol emissions from kerosene space heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leaderer, B.P.; Boone, P.M.; Hammond, S.K.

    1990-06-01

    Chamber studies were conducted on four unvented kerosene space heaters to assess emissions of total particle, sulfate, and acidic aerosol. The heaters tested represented four burner designs currently in use by the public. Kerosene space heaters are a potential source of fine particles ({<=} 2.5-{mu}m diameter), sulfate, and acidic aerosol indoors. Fine particle concentrations in homes in which the heaters are used may be increased in excess of 20 {mu}g/m{sup 3} over background levels. Sulfate and acidic aerosol levels in such homes could exceed average and peak outdoor concentrations. Maltuned heaters could produce exceptionally high levels of all air contaminantsmore » measured.« less

  6. Total particle, sulfate, and acidic aerosol emissions from kerosene space heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leaderer, B.P.; Boone, P.M.; Hammond, S.K.

    1990-01-01

    The article discusses chamber studies of four unvented kerosene space heaters to assess emissions of total particle, sulfate, and acidic aerosol. The heaters tested represented four burner designs currently in use by the public. Kerosene space heaters are a potential source of fine particles (= or < 2.5 micrometer diameter), sulfate, and acidic aerosol indoors. Fine particle concentrations in houses in which the heaters are used may be increased in excess of 20 micrograms/m3 over background levels. Sulfate and acidic aerosol levels in such houses could exceed average and peak outdoor concentrations. Maltuned heaters could produce exceptionally high levels ofmore » all air contaminants measured.« less

  7. Selected organic pollutant emissions from unvented kerosene space heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Traynor, G.W.; Apte, M.G.; Sokol, H.A.

    1990-08-01

    An exploratory study was performed to assess the semivolatile and nonvolatile organic pollutant emissions rates from unvented kerosene space heaters. A well-tuned radiant heater and maltuned convective heater were tested for semivolatile and nonvolatile organic pollutant emissions. Each heater was operated in a 27-m{sup 3} chamber with a prescribed on/off pattern. Organic compounds were collected on Teflon-impregnated glass filters backed by XAD-2 resin and analyzed by gas chromatography/mass spectrometry. Pollutant source strengths were calculated by use of a mass balance equation. The results show that kerosene heaters can emit polycyclic aromatic hydrocarbons (PAHs); nitrated PAHs; alkylbenzenes, phthalates; hydronaphthalenes; aliphatic hydrocarbons,more » alcohols, and ketones; and other organic compounds, some of which are known mutagens.« less

  8. Comparison of pollutant emission rates from unvented kerosene and gas space heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apte, M.G.; Traynor, G.W.

    1986-05-01

    In this paper the pollutant emission rates of all five types of unvented space heaters are compared. Pollutant emission rates for carbon dioxide, carbon monoxide (CO), nitric oxide, nitrogen dioxide (NO/sub 2/), formaldehyde, and submicron suspended particles were measured. Special emphasis is placed on CO and NO/sub 2/ emissions. Pollutant measurements were made in a 27-m/sup 3/ environmental chamber and emission rates were calculated using a mass-balance model. Emission rates for propane and natural gas space heaters were similar. Emissions from the various types of heaters fall into three distinct groups. The groups are better characterized by burner design thanmore » by the type of fuel used. Radiant kerosene heaters and infrared UVGSHs constitute one group; convective kerosene heaters and convective UVGSHs the second, and two-stage kerosene heaters the third group. When groups are compared, emission rates vary by an order of magnitude for carbon monoxide and for nitrogen dioxide. The two-stage kerosene heaters emitted the least CO and also the least NO/sub 2/ per unit of fuel energy consumed. The radiant/infrared heaters emitted the most CO, and the convective heaters emitted the most NO/sub 2/. The effects of various operation parameters such as the wick height for kerosene heaters and the air shutter adjustment for gas heaters are discussed. Convective UVGSHs operating at half input were found to have lower emission rates on average than when operating at full input. Some maltuned convective UVGSHs were capable of emitting very high amounts of CO. Kerosene heaters were found to emit more CO and NO/sub 2/ on average when they were operated with lowered wicks.« less

  9. Portable kerosene heater controversy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Decker, M.O.

    1982-04-01

    The National Kerosene Heater Association reports sales of slightly fewer than two million heaters in the United States between 1975 and 1979. More than one million were sold in 1980 and they project sales of eight to ten million by 1985. Kerosene heater dealers are urged to post warnings to customers specifying the grade of kerosene to be used. 1-K kerosene has a maximum sulfur content of .04% and is generally suitable for use in nonflue-connected burners. 2-K kerosene, with a sulfur content of as much as .30% should be used only in flue-connected burner applications. (JMT)

  10. CHARACTERIZATIONS OF POPULATION AND USAGE OF UNVENTED KEROSENE SPACE HEATERS

    EPA Science Inventory

    The report gives results of a study of the market penetration of unvented kerosene space heaters (UKSHs) in the residential sector, The study was aimed at gathering baseline information to help assess the magnitude and potential severity of a problem involving emissions from unve...

  11. CHARACTERIZATION OF POPULATION AND USAGE OF UNVENTED KEROSENE SPACE HEATERS

    EPA Science Inventory

    The report gives results of a study of the market penetration of unvented kerosene space heaters (UKSHs) in the residential sector, The study was aimed at gathering baseline information to help assess the magnitude and potential severity of a problem involving emissions from unve...

  12. SELECTED ORGANIC POLLUTANT EMISSIONS FROM UNVENTED KEROSENE HEATERS

    EPA Science Inventory

    An exploratory study was performed to assess the semivolatile and nonvolatile organic pollutant emission rates from unvented kerosene space heaters. A well-tuned radiant heater and maltuned convective heater were tested for semivolatile and nonvolatile organic pollutant emiss...

  13. COMPARISON OF MEASUREMENT TECHNIQUES FOR QUANTIFYING SELECTED ORGANIC EMISSIONS FROM KEROSENE SPACE HEATERS

    EPA Science Inventory

    The report goes results of (1) a comparison the hood and chamber techniques for quantifying pollutant emission rates from unvented combustion appliances, and (2) an assessment of the semivolatile and nonvolatile organic-compound emissions from unvented kerosene space heaters. In ...

  14. Emission factors of gaseous pollutants from recent kerosene space heaters and fuels available in France in 2010.

    PubMed

    Carteret, M; Pauwels, J-F; Hanoune, B

    2012-08-01

    Laboratory measurements of the gaseous emission factors (EF) from two recent kerosene space heaters (wick and injector) with five different fuels have been conducted in an 8-m(3) environmental chamber. The two heaters tested were found to emit mainly CO(2), CO, NO, NO(2), and some volatile organic compounds (VOCs). NO(2) is continuously emitted during use, with an EF of 100-450 μg per g of consumed fuel. CO is normally emitted mainly during the first minutes of use (up to 3 mg/g). Formaldehyde and benzene EFs were quantified at 15 and 16 μg/g, respectively, for the wick heater. Some other VOCs, such as 1,3-butadiene, were detected with lower EFs. We demonstrated the unsuitability of a 'biofuel' containing fatty acid methyl esters for use with the wick heater, and that the accumulation of soot on the same heater, whatever the fuel, leads to a dramatic increase in the CO EF, up to 16 mg/g, which could be responsible for chronic and acute CO intoxications. Our results show that in spite of new technologies and emission standards for unvented kerosene space heaters, as well as for the fuels, the use of these heaters in indoor environments still leads to NO(x) levels in excess of current health recommendations. Whereas injection heaters generate more nitrogen oxides than wick heaters, prolonged use of the latter leads to a soot buildup, concomitant with high CO emissions, which could be responsible for acute and chronic intoxications. The use of a biofuel in a wick heater is also of concern. Maintenance of the heaters and adequate ventilation of the room during use of kerosene space heaters are therefore of prime importance to reduce personal exposure. © 2011 John Wiley & Sons A/S.

  15. Characterization of kerosene-heater emissions inside two mobile homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burton, R.M.; Seila, R.A.; Wilson, W.E.

    1990-03-01

    In an effort to determine the impact of kerosene heater emissions on indoor air quality, measurements were made in and around two mobile homes at a rural mobile home park near Apex, NC. The sampling was performed at two single-wide mobile homes equipped with kerosene heaters. The concentrations of acidic aerosols and gases, fine and coarse particulate aerosol mass, carbon monoxide, nitrogen oxides, volatile organic compounds and semivolatiles, were determined for periods of heater operation and for periods in which heaters were not operated. Simultaneous outdoor measurements of acid aerosols and gases, fine and coarse aerosol mass, and volatile organicmore » compounds were conducted to determine the contribution of outdoor pollutants to the indoor concentrations. Comparisons between the concentrations obtained from the analysis of outdoor, heater-on, and heater-off samples allowed the authors to examine the impacts of the kerosene emissions on indoor concentrations. Concentrations of sulfates, aerosol strong acidity, fine and coarse aerosol mass, carbon monoxide, and sulfur dioxide were found to be higher when the heater was operated; however, these heater-on concentrations were comparable to those observed in moderately polluted atmospheres. Indoor concentrations of nitrous acid and nitrogen oxides during heater operation were found to be considerably higher than those observed in polluted atmospheres. Finally, use of kerosene heaters was found to be responsible for increased concentrations of non-methane volatile and semi-volatile organic compounds indoors. Acid aerosol indoor concentrations were quite variable during the study and were found to exist in the presence of excess ammonia.« less

  16. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  17. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  18. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  19. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  20. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  1. Unvented kerosene-heater emissions in mobile homes: Studies on indoor air particles, semivolatile organics, carbon monoxide, and mutagenicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mumford, J.L.; Lewtas, J.; Burton, R.M.

    1990-01-01

    The study was conducted to assess human exposure to air pollutants resulting from the use of kerosene heaters in mobile homes. It has been estimated that 15-17 million unvented kerosene heaters have been sold in the United States, and 33% of these heaters have been sold to mobile home residents. The emissions from kerosene heaters can result in high pollutants levels in mobile homes that have a small air volume and low ventilation rate. Indoor air exchange rate, temperature, and humidity were measured. Chemical analyses, including polycyclic aromatic hydrocarbon (PAH) and nitro PAH, also were performed on the indoor airmore » samples from a selected home with the kerosene heater on and off. Increases in CO and organic concentrations resulting from the use of kerosene heaters were found in most homes monitored. Chemical analysis data also suggested the presence of evaporated, unburned kerosene fuel present in semivolatile organics collected in the XAD samples. When kerosene heaters were on, 56% of the sampling days (in all homes) showed dose-response mutagenic activity and 19% showed mutagenic activity on the heater-off days. In comparison with the U.S. national ambient air standards, four out of the eight heaters investigated in this study emitted pollutants that exceeded the ambient air standards some days. These data suggested that emissions from unvented kerosene heaters can significantly impact indoor air quality in mobile homes and that these emissions contain carcinogenic compounds and can be potentially carcinogenic in humans.« less

  2. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  3. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  4. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  5. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  6. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  7. Impact of kerosene heater usage on indoor NO/sub 2/ exposures in 50 East Tennessee homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dudney, C.S.; Hawthorne, A.R.; Monar, K.P.

    1988-01-01

    As part of a study of indoor air quality in 300 houses in Roane County, Tennessee, a special study was made on kerosene heater usage and indoor pollutant levels, with emphasis on NO/sub 2/. Owners of 45 homes with kerosene heaters deployed pairs of passive NO/sub 2/ monitors on a weekly basis for ten weeks and recorded the weekly amount of heater use. Without correcting for house-specific factors, such as air exchange rate, indoor NO/sub 2/ levels were found to increase about 0.3 ppB per h/week of homeowner-reported heater use. In the absence of heater use, NO/sub 2/ levels weremore » about 10 ppB in houses with and without kerosene heaters. In four houses with kerosene heaters and one house without, continuous measurements were made of NO, NO/sub x/, SO/sub 2/, and CO. CO and SO/sub 2/ levels increased threefold and tenfold, respectively, when the heater was operated compared to when it was off. Mean SO/sub 2/ levels during heater operation were 57, 46, and 110 ppB in three houses with radiant heaters and 13.5 ppB in one house with a convective heater. 5 refs., 8 figs., 3 tabs.« less

  8. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  9. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  10. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  11. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  12. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  13. The impact of add-on catalytic devices on pollutant emissions from unvented kerosene heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apte, M.G.; Traynor, G.W.; Froehlich, D.A.

    1989-09-01

    Many studies have documented pollutant emission rates from kerosene heaters. Carbon monoxide (CO), carbon dioxide (CO{sub 2}), nitric oxide (NO), nitrogen dioxide (NO{sub 2}), formaldehyde (HCHO), suspended particles, and semivolatile and nonvolatile organic compounds, including some nitrated and non-nitrated polycyclic aromatic hydrocarbons, can be emitted by kerosene heaters. Recently, several add-on catalytic devices designed to reduce some pollutant emissions have become commercially available. The tests described here were designed to measure the impact of these devices on pollutant emissions from unvented kerosene heaters. Emissions of CO, NO, NO{sub 2}, HCHO, and total suspended particles were investigated in this study. Inmore » addition, analyses of particulate sulfur and chromium were conducted for some tests.« less

  14. Effects on carbon monoxide levels in mobile homes using unvented kerosene heaters for residential heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, R.; Walsh, D.; White, J.

    1992-01-01

    Carbon monoxide (CO) emission levels were continuously monitored in 8 mobile trailer homes less than 10 years old. These homes were monitored in an US EPA study on indoor air quality as affected by unvented portable kerosene heaters. Respondents were asked to operate their heaters in a normal fashion. CO, air exchange and temperature values were measured during the study in each home. Results indicate that consumers using unvented kerosene heaters may be unknowingly exposed to high CO levels without taking proper precautions.

  15. Evaluation of a dual-chamber kerosene-heater combustion technology. Topical report, June-December 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kardas, A.

    1987-10-01

    A kerosene heater equipped with a dual-chamber combustor was procured, tested, and technically evaluated to determine its applicability to natural gas combustion. The kerosene heater was found to have nitric oxide (NO), nitrogen dioxide (NO/sub 2/), and carbon monoxide (CO) emissions of 0.0)2, 0.006 and 0.02 lb/10/sup 6/ Btu input, respectively, much lower than those of blue-flame natural-gas combustors. A basic study was conducted to understand the interaction between kerosene combustion and the surrounding metal sleeves forming the dual chamber. Combustion characteristics of kerosene and natural gas were compared to formulate potential designs of low-emitting natural gas combustors. Three conceptsmore » were developed for low-emitting burners: an atmospheric burner to replace the kerosene wick in the dual chamber; the same concept with a powered vent; and a two-stage system equipped with a powered vent.« less

  16. Indoor air pollutants from unvented kerosene-heater emissions in mobile homes: Studies on particles, semivolatile organics, carbon monoxide, and mutagenicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mumford, J.L.; Williams, R.W.; Walsh, D.B.

    1991-01-01

    The study was conducted to assess human exposure to air pollutants resulting from the use of kerosene heaters in mobile homes. It has been estimated that 15-17 million unvented kerosene heaters have been sold in the United States, and 33% of these heaters have been sold to mobile home residents. The emissions from kerosene heaters can result in high pollutants levels in mobile homes that have a small air volume and low ventilation rate. Eight totally electric mobile homes with no smokers living in the homes were monitored for indoor air particles < 10 micrometer (PM10), semivolatile organics, carbon monoxidemore » (CO), and mutagenicity of semivolatile and particle-phase organics in Salmonella typhimurium TA98 without S9 using a microsuspension reverse-mutation assay. Each home was monitored for an average of 6.5 h/day, 3 days/week, for 4 weeks (2 weeks with the heater on and 2 weeks with the heater off) during the heating season of 1989. Indoor air exchange rate, temperature, and humidity were measured. Chemical analyses, including polycyclic aromatic hydrocarbon (PAH) and nitro PAH, also were performed on the indoor air samples from a selected home with the kerosene heater on and off. Increases in CO and organic concentrations resulting from the use of kerosene heaters were found in most homes monitored. Chemical analysis data also suggested the presence of evaporated, unburned kerosene fuel present in semivolatile organics collected in the XAD samples. In comparison with the U.S. national ambient air standards, four out of the eight heaters investigated in the study emitted pollutants that exceeded the ambient air standards some days. These data suggested that emissions from unvented kerosene heaters can significantly impact indoor air quality in mobile homes and that these emissions contain carcinogenic compounds and can be potentially carcinogenic in humans.« less

  17. Indoor air pollutants from unvented kerosene heater emissions in mobile homes: Studies on particles, semivolatile organics, carbon monoxide, and mutagenicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mumford, J.L.; Burton, R.M.; Svendsgaard, D.J.

    1991-10-01

    This study assessed human exposure to air pollutants from unvented kerosene heaters in mobile homes. Eight electric homes with no smokers were monitored for airborne particles of < 10 {mu}m in diameter (PM{sub 10}), semivolatile organics, and carbon monoxide with the kerosene heaters on and off. The organic emissions were assayed for polycyclic aromatic hydrocarbon (PAH), nitro-PAH, and for mutagenicity in a Salmonella typhimurium reverse mutation assay. Usage of kerosene heaters resulted in (a) a significant increase in CO and organic levels (including carcinogenic PAH and nitro-PAH), (b) no significant effect on PM{sub 10} levels, except in two homes, (c)more » the presence of unburned kerosene fuel, (d) an increase in mutagenicity (in TA98) of particle-phase organics in five homes, and (e) little mutagenicity in the semivolatile organics in TA98 and TA100. Four of the eight heaters investigated emitted pollutants that exceeded the US ambient air standards for the 24-h PM{sub 10} standard and/or CO standards (the 1-h peak or 8-h average standard). This study showed that kerosene heater emissions can significantly impact indoor air quality in mobile homes.« less

  18. 40 CFR 279.23 - On-site burning in space heaters.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false On-site burning in space heaters. 279... burning in space heaters. Generators may burn used oil in used oil-fired space heaters provided that: (a) The heater burns only used oil that the owner or operator generates or used oil received from...

  19. 40 CFR 279.23 - On-site burning in space heaters.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false On-site burning in space heaters. 279... burning in space heaters. Generators may burn used oil in used oil-fired space heaters provided that: (a) The heater burns only used oil that the owner or operator generates or used oil received from...

  20. 40 CFR 279.23 - On-site burning in space heaters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false On-site burning in space heaters. 279... burning in space heaters. Generators may burn used oil in used oil-fired space heaters provided that: (a) The heater burns only used oil that the owner or operator generates or used oil received from...

  1. 40 CFR 279.23 - On-site burning in space heaters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false On-site burning in space heaters. 279... burning in space heaters. Generators may burn used oil in used oil-fired space heaters provided that: (a) The heater burns only used oil that the owner or operator generates or used oil received from...

  2. 40 CFR 279.23 - On-site burning in space heaters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false On-site burning in space heaters. 279... burning in space heaters. Generators may burn used oil in used oil-fired space heaters provided that: (a) The heater burns only used oil that the owner or operator generates or used oil received from...

  3. Mutagenicity and Nitropyrene Concentration of Indoor Air Particulates Exhausted from a Kerosene Heater*1

    PubMed Central

    Kinouchi, Takemi; Nishifuji, Keiko; Tsutsui, Hideshi; Hoare, Sadako Louise

    1988-01-01

    The particulates in a room warmed with a radiant kerosene heater were collected, extracted and fractionated into diethyl ether‐soluble neutral, acidic and basic fractions. The mutagenicity of these fractions was measured with Salmonella typhimurium strains TA98, TA98NR, TA98/1,8‐DNP6 and TA100 in the presence and ahsence of S9 mix. Room air without the heater showed very low mutagenicity. However, a sample from a room at the beginning of the burning period showed very high mutagenicity (237 His+ revertants/plate/m*3 of air in strain TA98 in the absence of S9 mix). In contrast, emissions from the heater after it was burning stably showed low mutagenicity (9 His+ revertants/plate/m*3). The crude extract of particulates from the heater at the beginning of the burning period was analyzed by high‐pressure liquid chromatography (HPLC) and showed a considerable amount of nitropyrenes (NPs); the concentrations of 1‐NP and 1,6‐diNP were 1.62 ng and 0.149 ng/m*3 of air, respectively, and accounted for 1.2% and 17.6%, respectively, of the mutagenicity in strain TA98 in the absence of S9 mix. In addition, an HPLC‐Ames histogram showed that peaks of mutagenicity corresponding to 1‐NP and diNPs accounted for 75.7% (1‐NP, 4.9%; 1,6‐diNP, 17.1%; 1,8‐diNP, 46.3%; 1,3‐diNP, 7.4%) of the HPLC‐recovered mutagenicity for strain TA98 without S9 mix. These results suggest that kerosene heaters, especially immediately after ignition, create mutagenic substances such as NPs. PMID:3128503

  4. 46 CFR 52.25-15 - Fired thermal fluid heaters.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Fired thermal fluid heaters. 52.25-15 Section 52.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-15 Fired thermal fluid heaters. (a) Fired thermal fluid heaters shall be designed...

  5. 46 CFR 52.25-15 - Fired thermal fluid heaters.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Fired thermal fluid heaters. 52.25-15 Section 52.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-15 Fired thermal fluid heaters. (a) Fired thermal fluid heaters shall be designed...

  6. 46 CFR 52.25-15 - Fired thermal fluid heaters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Fired thermal fluid heaters. 52.25-15 Section 52.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-15 Fired thermal fluid heaters. (a) Fired thermal fluid heaters shall be designed...

  7. Indoor, outdoor, and regional summer and winter concentrations of PM10, PM2.5, SO4(2)-, H+, NH4+, NO3-, NH3, and nitrous acid in homes with and without kerosene space heaters.

    PubMed Central

    Leaderer, B P; Naeher, L; Jankun, T; Balenger, K; Holford, T R; Toth, C; Sullivan, J; Wolfson, J M; Koutrakis, P

    1999-01-01

    Twenty-four-hour samples of PM10 (mass of particles with aerodynamic diameter < or = 10 microm), PM2.5, (mass of particles with aerodynamic diameter < or = 2.5 microm), particle strong acidity (H+), sulfate (SO42-), nitrate (NO3-), ammonia (NH3), nitrous acid (HONO), and sulfur dioxide were collected inside and outside of 281 homes during winter and summer periods. Measurements were also conducted during summer periods at a regional site. A total of 58 homes of nonsmokers were sampled during the summer periods and 223 homes were sampled during the winter periods. Seventy-four of the homes sampled during the winter reported the use of a kerosene heater. All homes sampled in the summer were located in southwest Virginia. All but 20 homes sampled in the winter were also located in southwest Virginia; the remainder of the homes were located in Connecticut. For homes without tobacco combustion, the regional air monitoring site (Vinton, VA) appeared to provide a reasonable estimate of concentrations of PM2.5 and SO42- during summer months outside and inside homes within the region, even when a substantial number of the homes used air conditioning. Average indoor/outdoor ratios for PM2.5 and SO42- during the summer period were 1.03 +/- 0.71 and 0.74 +/- 0.53, respectively. The indoor/outdoor mean ratio for sulfate suggests that on average approximately 75% of the fine aerosol indoors during the summer is associated with outdoor sources. Kerosene heater use during the winter months, in the absence of tobacco combustion, results in substantial increases in indoor concentrations of PM2.5, SO42-, and possibly H+, as compared to homes without kerosene heaters. During their use, we estimated that kerosene heaters added, on average, approximately 40 microg/m3 of PM2.5 and 15 microg/m3 of SO42- to background residential levels of 18 and 2 microg/m3, respectively. Results from using sulfuric acid-doped Teflon (E.I. Du Pont de Nemours & Co., Wilmington, DE) filters in homes with

  8. Skin analysis following dermal exposure to kerosene in rats: the effects of postmortem exposure and fire.

    PubMed

    Hieda, Yoko; Tsujino, Yoshio; Xue, Yuying; Takayama, Koji; Fujihara, Junko; Kimura, Kojiro; Dekio, Satoshi

    2004-02-01

    To evaluate the usefulness of skin analysis for the forensic examination of cases involving postmortem dermal exposure to kerosene and/or fire, an experimental study using rats was performed. Rats received dermal exposure to kerosene before or after death, and the effect of fire was determined by burning an area of exposed skin after death. Kerosene concentrations in skin and blood were determined by gas chromatography-mass spectrometry and microscopic observation was performed for skin samples. No differences were observed in skin kerosene levels between antemortem and postmortem exposure. Kerosene concentrations in mildly burned skin where the stratum corneum (SC) was retained were approximately 84% compared to those in non-burned exposed skin, whereas concentrations in severely burned skin where the SC was almost completely burned off were 28% of non-burned skin. Even in non-exposed control skin 14% of the original kerosene concentrations could be detected, which was considered to be caused by contamination during the experimental protocol combined with kerosene's property of a high affinity for the SC. These results suggest that (1) skin analysis is useful in estimating the type of petroleum product involved in crimes or accidents even for postmortem exposure, (2) whether the SC is retained or not primarily determined the kerosene levels in burned skin, and (3) attention must be paid to evaluate the results obtained from skin samples in the light of the circumstances surrounding the case.

  9. 30 CFR 75.341 - Direct-fired intake air heaters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 75.341 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.341 Direct-fired intake air heaters. (a) If any system used to heat intake air malfunctions, the heaters affected shall switch...

  10. Fired heater for coal liquefaction process

    DOEpatents

    Ying, David H. S.

    1984-01-01

    A fired heater for a coal liquefaction process is constructed with a heat transfer tube having U-bends at regular intervals along the length thereof to increase the slug frequency of the multi-phase mixture flowing therethrough to thereby improve the heat transfer efficiency.

  11. 46 CFR 52.25-15 - Fired thermal fluid heaters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Each fired thermal fluid heater must be fitted with a control which prevents the heat transfer fluid from being heated above its flash point. (c) The heat transfer fluid must be chemically compatible with any cargo carried in the cargo tanks serviced by the heat transfer system. (d) Each fired thermal...

  12. 46 CFR 52.25-15 - Fired thermal fluid heaters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Each fired thermal fluid heater must be fitted with a control which prevents the heat transfer fluid from being heated above its flash point. (c) The heat transfer fluid must be chemically compatible with any cargo carried in the cargo tanks serviced by the heat transfer system. (d) Each fired thermal...

  13. Fired heater for coal liquefaction process

    DOEpatents

    Ying, David H. S.; McDermott, Wayne T.; Givens, Edwin N.

    1985-01-01

    A fired heater for a coal liquefaction process is operated under conditions to maximize the slurry slug frequency and thereby improve the heat transfer efficiency. The operating conditions controlled are (1) the pipe diameter and pipe arrangement, (2) the minimum coal/solvent slurry velocity, (3) the maximum gas superficial velocity, and (4) the range of the volumetric flow velocity ratio of gas to coal/solvent slurry.

  14. Diesel-fired self-pumping water heater

    NASA Astrophysics Data System (ADS)

    Gertsmann, Joseph

    1994-07-01

    The object of this project was to study the feasibility of pumping and heating water by sustained oscillatory vaporization and condensation in a fired heat exchanger. Portable field liquid fueled water heaters would facilitate heating water for sanitation, personal hygiene, food service, laundry, equipment maintenance, and decontamination presently available only from larger, less portable, motorized pumping units. The technical tasks consisted of: development of an analytical model, operation of proof-of-principal prototypes, and determination of the thermal and mechanical relationships to evaluate operating range and control characteristics. Four successive pump models were analyzed and tested. The final analytical model gave reasonable agreement with the experimental results, indicating that the actual pumping effect was an order of magnitude lower than originally anticipated. It was concluded that a thermally-activated self pumping water heater based on the proposed principle is not feasible.

  15. Self-extinguishing behavior of kerosene spray fire in a completely enclosed compartment

    NASA Astrophysics Data System (ADS)

    Wang, Changjian; Guo, Jin; Yan, Weigang; Lu, Shouxiang

    2013-10-01

    The self-extinguishing behavior of kerosene spray fire was investigated in a completely enclosed compartment with the size of 3 m × 3 m × 3.4 m. The spray was generated by locating one BETE nozzle at the center of the bottom wall. A series of spray fire videos were obtained by changing BETE nozzle type and injecting pressure. The results show that spray fire undergoes four stages: the growth stage, the quasi-steady stage, the stretch stage and the self-extinguishing stage. Consumption of large quantities of oxygen causes spray fire to first be stretched and then quench. In this process, fire base migrates away from spray region and leads to the emergence of ghosting fire. Ghosting fire promotes the instability of spray fire and large fluctuation of its height, which provides help to its self-extinguishing. With increasing the injecting pressure or the nozzle diameter, the self-extinguishing time decreases. It is found that the self-extinguishing time is approximately in inverse relation with injecting flow rate. Additionally, we also observed the occurrence of two-phase deflagration just after ignition, and it accelerates the spray fire growth and induces a larger fire height than the following quasi-steady spray fire. The deflagration turns stronger with increasing the injecting pressure.

  16. Emissions Characterization of Residential Wood-Fired Hydronic Heater Technologies

    EPA Science Inventory

    Residential wood-fired hydronic heaters (RWHHs) can negatively impact the local ambient air quality and thus are of major environmental concern in wood burning areas of the U. S. Few studies have been conducted which characterize the emissions from RWHHs. To address the lack of e...

  17. Space Station solar water heater

    NASA Technical Reports Server (NTRS)

    Horan, D. C.; Somers, Richard E.; Haynes, R. D.

    1990-01-01

    The feasibility of directly converting solar energy for crew water heating on the Space Station Freedom (SSF) and other human-tended missions such as a geosynchronous space station, lunar base, or Mars spacecraft was investigated. Computer codes were developed to model the systems, and a proof-of-concept thermal vacuum test was conducted to evaluate system performance in an environment simulating the SSF. The results indicate that a solar water heater is feasible. It could provide up to 100 percent of the design heating load without a significant configuration change to the SSF or other missions. The solar heater system requires only 15 percent of the electricity that an all-electric system on the SSF would require. This allows a reduction in the solar array or a surplus of electricity for onboard experiments.

  18. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  19. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  20. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  1. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  2. Solar water heater for NASA's Space Station

    NASA Technical Reports Server (NTRS)

    Somers, Richard E.; Haynes, R. Daniel

    1988-01-01

    The feasibility of using a solar water heater for NASA's Space Station is investigated using computer codes developed to model the Space Station configuration, orbit, and heating systems. Numerous orbit variations, system options, and geometries for the collector were analyzed. Results show that a solar water heater, which would provide 100 percent of the design heating load and would not impose a significant impact on the Space Station overall design is feasible. A heat pipe or pumped fluid radial plate collector of about 10-sq m, placed on top of the habitat module was found to be well suited for satisfying water demand of the Space Station. Due to the relatively small area required by a radial plate, a concentrator is unnecessary. The system would use only 7 to 10 percent as much electricity as an electric water-heating system.

  3. Blender for Antimisting Kerosene

    NASA Technical Reports Server (NTRS)

    Parikh, Pradip G.; Sarohia, Virendra; Yavrouian, Andre H.

    1987-01-01

    Blender continuously disperses controlled amount of flammability-reducing additive into stream of jet fuel. Resulting mixture consists of homogeneous suspension of additive polymer particles in fuel. Particles dissolve within 15 to 30 min, without agitation, forming airplane fuel known as antimisting kerosene which promises to reduce danger from fire in crashes.

  4. Hollow cathode heater development for the Space Station plasma contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1993-01-01

    A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.

  5. Generic Verification Protocol for Determination of Emissions from Cleaner Outdoor Wood-Fired Hydronic Heaters

    EPA Science Inventory

    This protocol describes the Environmental Technology Verification Program's considerations and requirements for verification of emissions reduction provided by cleaner outdoor wood-fired hydronic heaters. Outdoor wood-burning units provide heat and hot water for homes and other b...

  6. Development and Validation of a Gas-Fired Residential Heat Pump Water Heater - Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael Garrabrant; Roger Stout; Paul Glanville

    2013-01-21

    For gas-fired residential water heating, the U.S. and Canada is predominantly supplied by minimum efficiency storage water heaters with Energy Factors (EF) in the range of 0.59 to 0.62. Higher efficiency and higher cost ($700 - $2,000) options serve about 15% of the market, but still have EFs below 1.0, ranging from 0.65 to 0.95. To develop a new class of water heating products that exceeds the traditional limit of thermal efficiency, the project team designed and demonstrated a packaged water heater driven by a gas-fired ammonia-water absorption heat pump. This gas-fired heat pump water heater can achieve EFs ofmore » 1.3 or higher, at a consumer cost of $2,000 or less. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, the Gas Technology Institute (GTI), and Georgia Tech, the cross-functional team completed research and development tasks including cycle modeling, breadboard evaluation of two cycles and two heat exchanger classes, heat pump/storage tank integration, compact solution pump development, combustion system specification, and evaluation of packaged prototype GHPWHs. The heat pump system extracts low grade heat from the ambient air and produces high grade heat suitable for heating water in a storage tank for domestic use. Product features that include conventional installation practices, standard footprint and reasonable economic payback, position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions from domestic hot water production.« less

  7. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal fluid heater, and heating boilers. (a) To determine the appropriate part of the regulations where...

  8. Kerosene-Fuel Engine Testing Under Way

    NASA Image and Video Library

    2003-11-17

    NASA Stennis Space Center engineers conducted a successful cold-flow test of an RS-84 engine component Sept. 24. The RS-84 is a reusable engine fueled by rocket propellant - a special blend of kerosene - designed to power future flight vehicles. Liquid oxygen was blown through the RS-84 subscale preburner to characterize the test facility's performance and the hardware's resistance. Engineers are now moving into the next phase, hot-fire testing, which is expected to continue into February 2004. The RS-84 engine prototype, developed by the Rocketdyne Propulsion and Power division of The Boeing Co. of Canoga Park, Calif., is one of two competing Rocket Engine Prototype technologies - a key element of NASA's Next Generation Launch Technology program.

  9. Kerosene-Fuel Engine Testing Under Way

    NASA Technical Reports Server (NTRS)

    2003-01-01

    NASA Stennis Space Center engineers conducted a successful cold-flow test of an RS-84 engine component Sept. 24. The RS-84 is a reusable engine fueled by rocket propellant - a special blend of kerosene - designed to power future flight vehicles. Liquid oxygen was blown through the RS-84 subscale preburner to characterize the test facility's performance and the hardware's resistance. Engineers are now moving into the next phase, hot-fire testing, which is expected to continue into February 2004. The RS-84 engine prototype, developed by the Rocketdyne Propulsion and Power division of The Boeing Co. of Canoga Park, Calif., is one of two competing Rocket Engine Prototype technologies - a key element of NASA's Next Generation Launch Technology program.

  10. Status of Hollow Cathode Heater Development for the Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1994-01-01

    A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Heater tests included testing of the heater unit alone and plasma contactor and ion thruster testing. To date, eight heaters have been or are being processed through heater unit testing, two through plasma contactor testing and three through ion thruster testing, all using direct current power supplies. Comparisons of data from heater unit performance tests before cyclic testing, plasma contactor tests, and ion thruster tests at the ignition input current level show the average deviation of input power and tube temperature near the cathode tip to be +/-0.9 W and +/- 21 C, respectively. Heater unit testing included cyclic testing to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Four additional heaters successfully completed 6300, 6300, 700, and 700 cycles. Heater unit testing is currently ongoing for three heaters which have to date accumulated greater than 7250, greater than 5500, and greater than 5500 cycles, respectively.

  11. Process for Testing Compaction of a Swaged Heater for an Anode Sub-Assembly of a Hollow Cathode Assembly

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J. (Inventor); Verhey, Timothy R. R. (Inventor); Soulas, George C. (Inventor)

    2003-01-01

    A process for testing compaction of a swaged heater for an anode sub-assembly of a Hollow Cathode Assembly (HCA), in which a test sample is cleaned, its mass measured before and after immersion in kerosene for 24 hours, and a compaction percentage calculated. A swaged heater is rejected if the compaction percentage exceeds 84%, plus or minus 4%.

  12. Experimentation on bio-kerosene stove using organic additive

    NASA Astrophysics Data System (ADS)

    Varshini, M.; Shetty, Divakar

    2017-07-01

    One of the basic worthy item used in most of the villages even now a day's also is the kerosene stove. But in the current scenario, the petroleum products are been replenished. So an alternate fuel should be found in order delve. This work is to check the contingency of blending pongamia oil and kerosene in which is used as an additive. Pongamia is one of the forest based fast growing evergreen tree which is capable of yielding 9 - 90 kg seeds from which 25% of oil can be extracted. Distilled cow urine is to be used so that the fuel can be stored for longer time and is odorless. Blends of 10% to 70% neat pongamia oil - kerosene(KEP) and pongamia oil - kerosene with additive(KEPWA) are prepared. The properties such as flash point, fire point and viscosity are determined. The blends are been compared by doing emission test. The blends with additive showed better properties and reducing in emission characteristics compared to neat blends. It is also observed that emission of CO is decreasing with increasing blends.

  13. Determination of polycyclic aromatic hydrocarbons in kerosene and bio-kerosene soot.

    PubMed

    Andrade-Eiroa, Auréa; Leroy, Valérie; Dagaut, Philippe; Bedjanian, Yuri

    2010-03-01

    Here we report a new, efficient and reliable analytical methodology for sensitive and selective quantification of Polycyclic Aromatic Hydrocarbons (PAHs) in soot samples. The methodology developed is based on ultrasonic extraction of the soot-bound PAHs into small volumes of acetonitrile, purification of the extracts through C(18) Solid Phase Extraction (SPE) cartridges and analysis by Reverse Phase Liquid Chromatography (RPLC) with UV and fluorimetric detection. For the first time, we report the convenience of adapting the SPE procedure to the nature of the soot samples. As a matter of fact, extracts containing high percentage of unpolar material are recommended to be cleaned with acetone, whereas extracts poor in unpolar compounds can be efficiently cleaned with methanol. The method was satisfactorily applied to kerosene and bio-kerosene soot from atmospheric open diffusion flames (pool fires) and premixed flames achieving Quantification and Detection limits in the range ng mg(-1) soot and recoveries about 90% for most of the PAHs studied. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  14. Is your electric process heater safe?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tiras, C.S.

    2000-04-01

    Over the past 35 years, electric process heaters (EPHs) have been used to heat flowing fluids in different sectors of the energy industry: oil and gas exploration and production, refineries, petrochemical plants, pipeline compression facilities and power-generation plants. EPHs offer several advantages over fired heaters and shell-and-tube exchangers, which have been around for many years, including: smaller size, lighter weight, cleaner operation, lower capital costs, lower maintenance costs, no emissions or leakage, better control and improved safety. However, while many industrial standards have addressed safety concerns of fired heaters and shell-and-tube exchangers (API, TEMA, NFPA, OSHA and NEC), no standardsmore » address EPHs. The paper presents a list of questions that plant operators need to ask about the safety of their electric process heaters. The answers are also given.« less

  15. 26 CFR 48.4082-6 - Kerosene; exemption for aviation-grade kerosene.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Kerosene; exemption for aviation-grade kerosene..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-6 Kerosene; exemption for aviation-grade kerosene... entry of aviation-grade kerosene that is destined for use as a fuel in an aircraft. (b) Definition. For...

  16. 26 CFR 48.4082-6 - Kerosene; exemption for aviation-grade kerosene.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Kerosene; exemption for aviation-grade kerosene..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-6 Kerosene; exemption for aviation-grade kerosene... entry of aviation-grade kerosene that is destined for use as a fuel in an aircraft. (b) Definition. For...

  17. 26 CFR 48.4082-6 - Kerosene; exemption for aviation-grade kerosene.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Kerosene; exemption for aviation-grade kerosene..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-6 Kerosene; exemption for aviation-grade kerosene... entry of aviation-grade kerosene that is destined for use as a fuel in an aircraft. (b) Definition. For...

  18. 26 CFR 48.4082-6 - Kerosene; exemption for aviation-grade kerosene.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Kerosene; exemption for aviation-grade kerosene..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-6 Kerosene; exemption for aviation-grade kerosene... entry of aviation-grade kerosene that is destined for use as a fuel in an aircraft. (b) Definition. For...

  19. Infrared Heater Used in Qualification Testing of International Space Station Radiators

    NASA Technical Reports Server (NTRS)

    Ziemke, Robert A.

    2004-01-01

    Two heat rejection radiator systems for the International Space Station (ISS) have undergone thermal vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the Space Power Facility (SPF), the largest thermal vacuum chamber in the world. The heat rejection system radiator was tested first; it removes heat from the ISS crew living quarters. The second system tested was the photovoltaic radiator (PVR), which rejects heat from the ISS photovoltaic arrays and the electrical power-conditioning equipment. The testing included thermal cycling, hot- and cold-soaked deployments, thermal gradient deployments, verification of the onboard heater controls, and for the PVR, thermal performance tests with ammonia flow. Both radiator systems are orbital replacement units for ease of replacement on the ISS. One key to the success of these tests was the performance of the infrared heater system. It was used in conjunction with a gaseous-nitrogen-cooled cryoshroud in the SPF vacuum chamber to achieve the required thermal vacuum conditions for the qualification tests. The heater, which was designed specifically for these tests, was highly successful and easily met the test requirements. This report discusses the heating requirements, the heater design features, the design approach, and the mathematical basis of the design.

  20. MHD oxidant intermediate temperature ceramic heater study

    NASA Technical Reports Server (NTRS)

    Carlson, A. W.; Chait, I. L.; Saari, D. P.; Marksberry, C. L.

    1981-01-01

    The use of three types of directly fired ceramic heaters for preheating oxygen enriched air to an intermediate temperature of 1144K was investigated. The three types of ceramic heaters are: (1) a fixed bed, periodic flow ceramic brick regenerative heater; (2) a ceramic pebble regenerative heater. The heater design, performance and operating characteristics under conditions in which the particulate matter is not solidified are evaluated. A comparison and overall evaluation of the three types of ceramic heaters and temperature range determination at which the particulate matter in the MHD exhaust gas is estimated to be a dry powder are presented.

  1. 49 CFR 393.77 - Heaters.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... heater shall comply with the following requirements: (a) Prohibited types of heaters. The installation or use of the following types of heaters is prohibited: (1) Exhaust heaters. Any type of exhaust heater... heater which conducts engine compartment air into any such space. (2) Unenclosed flame heaters. Any type...

  2. 49 CFR 393.77 - Heaters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... heater shall comply with the following requirements: (a) Prohibited types of heaters. The installation or use of the following types of heaters is prohibited: (1) Exhaust heaters. Any type of exhaust heater... heater which conducts engine compartment air into any such space. (2) Unenclosed flame heaters. Any type...

  3. Kerosene-induced asthma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez de la Vega, A.; Casaco, A.; Garcia, M.

    1990-04-01

    Clinical evaluation of 286 asthmatic women showed 15.5% of those who improved clinically had contact with kerosene, while 43.9% of those who failed to improve used kerosene as fuel for cooking. In 16 women the onset of asthma occurred soon after they began to use kerosene. Kerosene can cause and aggravate asthma.

  4. Kerosene: a review of household uses and their hazards in low- and middle-income countries.

    PubMed

    Lam, Nicholas L; Smith, Kirk R; Gauthier, Alison; Bates, Michael N

    2012-01-01

    Kerosene has been an important household fuel since the mid-19th century. In developed countries its use has greatly declined because of electrification. However, in developing countries, kerosene use for cooking and lighting remains widespread. This review focuses on household kerosene uses, mainly in developing countries, their associated emissions, and their hazards. Kerosene is often advocated as a cleaner alternative to solid fuels, biomass and coal, for cooking, and kerosene lamps are frequently used when electricity is unavailable. Globally, an estimated 500 million households still use fuels, particularly kerosene, for lighting. However, there are few studies, study designs and quality are varied, and results are inconsistent. Well-documented kerosene hazards are poisonings, fires, and explosions. Less investigated are exposures to and risks from kerosene's combustion products. Some kerosene-using devices emit substantial amounts of fine particulates, carbon monoxide (CO), nitric oxides (NO(x)), and sulfur dioxide (SO(2)). Studies of kerosene used for cooking or lighting provide some evidence that emissions may impair lung function and increase infectious illness (including tuberculosis), asthma, and cancer risks. However, there are few study designs, quality is varied, and results are inconsistent. Considering the widespread use in the developing world of kerosene, the scarcity of adequate epidemiologic investigations, the potential for harm, and the implications for national energy policies, researchers are strongly encouraged to consider collecting data on household kerosene uses in studies of health in developing countries. Given the potential risks of kerosene, policymakers may consider alternatives to kerosene subsidies, such as shifting support to cleaner technologies for lighting and cooking.

  5. KEROSENE: A REVIEW OF HOUSEHOLD USES AND THEIR HAZARDS IN LOW- AND MIDDLE-INCOME COUNTRIES

    PubMed Central

    Lam, Nicholas L.; Smith, Kirk R.; Gauthier, Alison; Bates, Michael N.

    2013-01-01

    Kerosene has been an important household fuel since the mid-19th century. In developed countries its use has greatly declined because of electrification. However, in developing countries, kerosene use for cooking and lighting remains widespread. This review focuses on household kerosene uses, mainly in developing countries, their associated emissions, and their hazards. Kerosene is often advocated as a cleaner alternative to solid fuels, biomass and coal, for cooking, and kerosene lamps are frequently used when electricity is unavailable. Globally, an estimated 500 million households still use fuels, particularly kerosene, for lighting. However, there are few studies, study designs and quality are varied, and results are inconsistent. Well-documented kerosene hazards are poisonings, fires, and explosions. Less investigated are exposures to and risks from kerosene’s combustion products. Some kerosene-using devices emit substantial amounts of fine particulates, carbon monoxide (CO), nitric oxides (NOx), and sulfur dioxide (SO2). Studies of kerosene used for cooking or lighting provide some evidence that emissions may impair lung function and increase infectious illness (including tuberculosis), asthma, and cancer risks. However, there are few study designs, quality is varied, and results are inconsistent. Considering the widespread use in the developing world of kerosene, the scarcity of adequate epidemiologic investigations, the potential for harm, and the implications for national energy policies, researchers are strongly encouraged to consider collecting data on household kerosene uses in studies of health in developing countries. Given the potential risks of kerosene, policymakers may consider alternatives to kerosene subsidies, such as shifting support to cleaner technologies for lighting and cooking. PMID:22934567

  6. An Experimental and Analytical Investigation of Stirling Space Power Converter Heater Head

    NASA Technical Reports Server (NTRS)

    Abdul-Aziz, Ali; Bartolotta, Paul; Tong, Mike; Allen, Gorden

    1995-01-01

    NASA has identified the Stirling power converter as a prime candidate for the next generation power system for space applications requiring 60000 hr of operation. To meet this long-term goal, several critical components of the power converter have been analyzed using advanced structural assessment methods. Perhaps the most critical component, because of its geometric complexity and operating environment, is the power converter's heater head. This report describes the life assessment of the heater head which includes the characterization of a viscoplastic material model, the thermal and structural analyses of the heater head, and the interpolation of fatigue and creep test results of a nickel-base superalloy, Udimet 720 LI (Low Inclusions), at several elevated temperatures for life prediction purposes.

  7. Semivolatile and volatile organic compound emissions from wood-fired hydronic heaters.

    PubMed

    Aurell, Johanna; Gullett, Brian K; Tabor, Dennis; Touati, Abderrahmane; Oudejans, Lukas

    2012-07-17

    Emissions including polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), polyaromatic hydrocarbons (PAHs), and volatile organic compounds (VOCs), were sampled from different wood-fired hydronic heater (HH) technologies. Four commercially available HH technologies were studied: a single-stage conventional combustor with natural updraft, a three-stage downdraft combustion system, a bottom-fed pellet burner, and a two-stage heater with both a combustion and gasification chamber. The fuel consisted of three wood types (red oak, white pine, and white ash), one hardwood pellet brand, and one fuel mixture containing 95% red oak and 5% residential refuse by weight. The various HHs and fuel combinations were tested in a realistic homeowner fuel-charging scenario. Differences in emission levels were found between HH technologies and fuel types. PCDD/PCDF emissions ranged from 0.004 to 0.098 ng toxic equivalency/MJ(input) and PAHs from 0.49 to 54 mg/MJ(input). The former was increased by the presence of 5% by weight refuse. The white pine fuel had the highest PAH emission factor, while the bottom fed pellet burner had the lowest. The major VOCs emitted were benzene, acetylene, and propylene. The highest emissions of PAHs, VOCs, and PCDDs/PCDFs were observed with the conventional unit, likely due to the rapid changes in combustion conditions effected by the damper opening and closing.

  8. Gas-fired radiant heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rattner, D.

    1987-01-06

    A heater apparatus is described comprising a plurality of porous tile members arranged in an elongated series; fuel distribution means adapted to support the tile members and having a baffled compartmentalized chamber transversely integrally formed therein for delivering a predetermined ignitable fuel mixture evenly to the tile members; and air circulation means adapted to substantially encase the fuel distribution means for circulating cooling air thereabout. The air circulation means is formed to provide an elongated and deflected air gap along opposite edges thereof to direct vented air away from the tile members.

  9. Dampers for Natural Draft Heaters: Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lutz, James D.; Biermayer, Peter; King, Derek

    2008-10-27

    Energy required for water heating accounts for approximately 40percent of national residential natural gas consumption in California. With water heating contributing such a substantial portion of natural gas consumption, it is important to pay attention to water heater efficiencies. This paper reports on an investigation of a patented, buoyancy-operated flue damper. It is an add-on design to a standard atmospherically vented natural-draft gas-fired storage water heater. The flue damper was expected to reduce off-cycle standby losses, which would lead to improvements in the efficiency of the water heater. The test results showed that the Energy Factor of the baseline watermore » heater was 0.576. The recovery efficiency was 0.768. The standby heat loss coefficient was 10.619 (BTU/hr-oF). After the damper was installed, the test results show an Energy Factor for the baseline water heater of 0.605. The recovery efficiency was 0.786. The standby heat loss coefficient was 9.135 (BTU/hr-oF). The recovery efficiency increased 2.3percent and the standby heat loss coefficient decreased 14percent. When the burner was on, the baseline water heater caused 28.0 CFM of air to flow from the room. During standby, the flow was 12.4 CFM. The addition of the damper reduced the flow when the burner was on to 23.5 CFM. During standby, flow with the damper was reduced to 11.1 CFM. The flue damper reduced off-cycle standby losses, and improved the efficiency of the water heater. The flue damper also improved the recovery efficiency of the water heater by restricting on-cycle air flows through the flue.With or without the flue damper, off-cycle air flow upthe stack is nearly half the air flow rate as when the burner is firing.« less

  10. Catalyst for cracking kerosene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsie, C. H.

    1985-06-04

    A catalyst capable of cracking kerosene under lower pressure and temperature comprising kerosene; metal powder mixture of chromium powder, copper powder, lead powder, zinc powder, nickel powder, manganese powder in an amount of 12 to 13 parts by weight per 100 parts by weight of said kerosene; sulfuric acid in an amount of 15 to 30 parts by weight per 100 parts by weight of said kerosene; inorganic powder mixture of aluminum oxide powder, serpentine powder, alum powder, magnesium oxide powder, limestone powder, slake lime powder, silica powder, and granite powder in an amount of 150 to 170 parts bymore » weight per 100 parts by weight of said kerosene.« less

  11. Manual Fire Suppression Methods on Typical Machinery Space Spray Fires

    DTIC Science & Technology

    1990-07-31

    Aqueous Film Forming Foam Manuscnpt approved April 25, 1990. ( AFFF ), has been incorporated in machinery space fire protection systems to...distribution unlimited. 13. ABSTRACT (Maximum 200 words) A series of tests was conducted to evaluate the effectiveness of Aqueous Film Forming Foami ( AFFF ...machinery space fire protection systems to control running fuel and fuel spray fires (PKP side of TAFES), and bilge fires ( aqueous film forming foam

  12. Kerosene Oil Poisoning among Children in Rural Sri Lanka.

    PubMed

    Dayasiri, M B Kavinda Chandimal; Jayamanne, Shaluka F; Jayasinghe, Chamilka Y

    2017-01-01

    Kerosene oil poisoning is one of common presentations to emergency departments among children in rural territories of developing countries. This study aimed to describe clinical manifestations, reasons for delayed presentations, harmful first aid practices, complications, and risk factors related to kerosene oil poisoning among children in rural Sri Lanka. This multicenter study was conducted in North-Central province of Sri Lanka involving all in-patient children with acute kerosene oil poisoning. Data were collected over seven years from thirty-six hospitals in the province. Data collection was done by pretested, multistructured questionnaires and a qualitative study. Male children accounted for 189 (60.4%) while 283 (93%) children were below five years. The majority of parents belonged to farming community. Most children ingested kerosene oil in home kitchen. Mortality rate was 0.3%. Lack of transport facilities and financial resources were common reasons for delayed management. Hospital transfer rate was 65.5%. Thirty percent of caregivers practiced harmful first aid measures. Commonest complication was chemical pneumonitis. Strongest risk factors for kerosene oil poisoning were unsafe storage, inadequate supervision, and inadequate house space. Effect of safe storage and community education in reducing the burden of kerosene oil poisoning should be evaluated. Since many risk factors interact to bring about the event of poisoning in a child, holistic approaches to community education in rural settings are recommended.

  13. Kerosene Oil Poisoning among Children in Rural Sri Lanka

    PubMed Central

    Jayamanne, Shaluka F.; Jayasinghe, Chamilka Y.

    2017-01-01

    Introduction Kerosene oil poisoning is one of common presentations to emergency departments among children in rural territories of developing countries. This study aimed to describe clinical manifestations, reasons for delayed presentations, harmful first aid practices, complications, and risk factors related to kerosene oil poisoning among children in rural Sri Lanka. Methods This multicenter study was conducted in North-Central province of Sri Lanka involving all in-patient children with acute kerosene oil poisoning. Data were collected over seven years from thirty-six hospitals in the province. Data collection was done by pretested, multistructured questionnaires and a qualitative study. Results Male children accounted for 189 (60.4%) while 283 (93%) children were below five years. The majority of parents belonged to farming community. Most children ingested kerosene oil in home kitchen. Mortality rate was 0.3%. Lack of transport facilities and financial resources were common reasons for delayed management. Hospital transfer rate was 65.5%. Thirty percent of caregivers practiced harmful first aid measures. Commonest complication was chemical pneumonitis. Strongest risk factors for kerosene oil poisoning were unsafe storage, inadequate supervision, and inadequate house space. Conclusions Effect of safe storage and community education in reducing the burden of kerosene oil poisoning should be evaluated. Since many risk factors interact to bring about the event of poisoning in a child, holistic approaches to community education in rural settings are recommended. PMID:29348762

  14. Development of a Prototype Military Field Space Heater

    DTIC Science & Technology

    1983-04-01

    COMBUSTION HEATERS TENT HEATERS LIQUID FUELS LIQUID FUEL BURNERS 2&< ABSTRACT rCamrtbmum «o rarerem ataT» ft namteaamry mod Identity by block...M1941 heater. This prototype features a large triple stage burner obtained from Holland that uses staged combustion to achieve clean burning with...M1941. This Dutch burner features staged combustion , which results in complete and very clean burning of diesel fuel. This report covers fabrication and

  15. Pyopneumothorax following suicidal kerosene ingestion

    PubMed Central

    Verma, S K; Kapoor, Neha; Bhaskar, Ravi; Upadhyay, Rashmi

    2012-01-01

    Liquid hydrocarbons derived from petroleum are widely used in household and industry. Many hydrocarbons in kerosene, such as hexane, naphthalene, octane and phenanthrene, are toxic to humans. Pulmonary toxicity is the major cause of morbidity and mortality followed by central nervous-system and cardiovascular complications.1 As kerosene is a mixture of chemicals, there is no definitive absorption, distribution, metabolism and excretion. The major route of exposure is by inhalation of liquid (aspiration). Kerosene vapours may be mildly irritating to the respiratory system and spray applications of kerosene may provoke signs of pulmonary irritation such as coughing and dyspnoea. Kerosene aspiration leads to inflammation and loss of surfactant. Secondary effects in the lungs include pneumothorax, pneumatocele or bronchopleural fistula. Here, we are presenting a case of pyopneumothorax after kerosene consumption. PMID:23257648

  16. Pyopneumothorax following suicidal kerosene ingestion.

    PubMed

    Verma, S K; Kapoor, Neha; Bhaskar, Ravi; Upadhyay, Rashmi

    2012-12-18

    Liquid hydrocarbons derived from petroleum are widely used in household and industry. Many hydrocarbons in kerosene, such as hexane, naphthalene, octane and phenanthrene, are toxic to humans. Pulmonary toxicity is the major cause of morbidity and mortality followed by central nervous-system and cardiovascular complications. As kerosene is a mixture of chemicals, there is no definitive absorption, distribution, metabolism and excretion. The major route of exposure is by inhalation of liquid (aspiration). Kerosene vapours may be mildly irritating to the respiratory system and spray applications of kerosene may provoke signs of pulmonary irritation such as coughing and dyspnoea. Kerosene aspiration leads to inflammation and loss of surfactant. Secondary effects in the lungs include pneumothorax, pneumatocele or bronchopleural fistula. Here, we are presenting a case of pyopneumothorax after kerosene consumption.

  17. One-year assessment of a solar space/water heater--Clinton, Mississippi

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Unit called "System 4" integrated into space-heating and hot-water systems of dormitory satisfied 32 percent of building heat load. System 4 includes flat-plate air collectors, circulation blowers, rock storage bed with heat exchanger, two hot water tanks, and auxiliary heaters. Report describes performance of system and subsystems, operating-energy requirements and savings, and performance parameters.

  18. Analysis of the performance and space-conditioning impacts of dedicated heat-pump water heaters

    NASA Astrophysics Data System (ADS)

    Morrison, L.; Swisher, J.

    1980-12-01

    The operation of a newly marketed dedicated heat pump water heater (HPWH) which utilizes an air to water heat pump, costs about $1000 installed, and obtains a coefficient of performance (COP) of about 2.0 in laboratory and field tests, is a space conditioning benefit if an air conditioning load exists and a penalty if a space heating load exists. A simulation was developed to model the thermal performance of a residence with resistance baseboard heat, air conditioning, and either heat pump or resistance water heating. The building characteristics were adapted (Madison, Wisconsin; Washington, DC; and Ft. Worth, Texas) and the system was simulated for a year with typical weather data. For each city, HPWH COPs are calculated monthly and yearly. The water heating and space conditioning energy requirements of HPWH operation are compared with those of resistance water heater operation to determine the relative performance ratio of the HPWH.

  19. Measure Guideline: Transitioning to a Tankless Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brozyna, K.; Rapport, A.

    2012-09-01

    This Measure Guideline provides information to help residential builders and retrofitters with the design, specification, selection, implementation, installation, and maintenance issues of transitioning from tank-type water heaters to tankless water heaters. The report compares the differences between tankless and tank-type water heaters, highlighting the energy savings that can be realized by adopting tankless water heaters over tank-type water heaters. Selection criteria and risks discussed include unit sizing and location, water distribution system, plumbing line length and diameter, water quality, electrical backup, and code issues. Cost and performance data are provided for various types of tankless and tank-type water heaters, bothmore » natural gas fired and electric. Also considered are interactions between the tankless water heater and other functional elements of a house, such as cold water supply and low-flow devices. Operating costs and energy use of water distribution systems for single- and two-story houses are provided, along with discussion of the various types of distribution systems that can be used with tankless water heaters. Finally, details to prepare for proper installation of a tankless water heater are described.« less

  20. Heat transfer in hybrid fibre reinforced concrete-steel composite column exposed to a gas-fired radiant heater

    NASA Astrophysics Data System (ADS)

    Štefan, R.; Procházka, J.; Novák, J.; Fládr, J.; Wald, F.; Kohoutková, A.; Scheinherrová, L.; Čáchová, M.

    2017-09-01

    In the paper, a gas-fired radiant heater system for testing of structural elements and materials at elevated temperatures is described. The applicability of the system is illustrated on an example of the heat transfer experiment on a hybrid fibre reinforced concrete-steel composite column specimen. The results obtained during the test are closely analysed by common data visualization techniques. The experiment is simulated by a mathematical model of heat transfer, assuming the material data of the concrete determined by in-house measurements. The measured and calculated data are compared and discussed.

  1. 89. ARAIII. Petrochem oilfired gas heater installed in reactor building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    89. ARA-III. Petro-chem oil-fired gas heater installed in reactor building (ARA-608). View is at floor level. Shows hand rails around heater pit and top of pit extending upwards through ceiling. January 20, 1959. Ineel photo no. 59-321. Photographer: Jack L. Anderson. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  2. Fire safety concerns in space operations

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1987-01-01

    This paper reviews the state-of-the-art in fire control techniques and identifies important issues for continuing research, technology, and standards. For the future permanent orbiting facility, the space station, fire prevention and control calls for not only more stringent fire safety due to the long-term and complex missions, but also for simplified and flexible safety rules to accommodate the variety of users. Future research must address a better understanding of the microgravity space environment as it influences fire propagation and extinction and the application of the technology of fire detection, extinguishment, and material assessment. Spacecraft fire safety should also consider the adaptation of methods and concepts derived from aircraft and undersea experience.

  3. 46 CFR 61.30-5 - Preparation of thermal fluid heater for inspection and test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Preparation of thermal fluid heater for inspection and test. 61.30-5 Section 61.30-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-5 Preparation of thermal fluid heater for...

  4. Emissions characterization of residential wood-fired hydronic heater technologies

    NASA Astrophysics Data System (ADS)

    Kinsey, John S.; Touati, Abderrahmane; Yelverton, Tiffany L. B.; Aurell, Johanna; Cho, Seung-Hyun; Linak, William P.; Gullett, Brian K.

    2012-12-01

    Residential wood-fired hydronic heaters (RWHHs) can negatively impact the local ambient air quality and thus are an environmental concern in wood burning areas of the U. S. Only a few studies have been conducted which characterize the emissions from RWHHs. To address the lack of emissions data, a study was conducted on four appliances of differing design using multiple fuel types to determine their thermal, boiler, and combustion efficiency as well as the emissions of carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), nitrous oxide (N2O), methane (CH4), total particulate matter (PM) mass, and particle number as well as particle size distribution (PSD). Three of these appliances were fired with split-log cordwood with the fourth unit using hardwood pellets. The measured thermal efficiencies for the appliances tested varied from 22 to 44% and the combustion efficiencies from 81 to 98%. Depending on appliance and fuel type, the emission factors ranged from about 1300 to 1800 g kg-1 dry fuel for CO2, 8-190 g kg-1 dry fuel for CO, <1-54 g kg-1 dry fuel for THC and 6-120 mg kg-1 for N2O. For the particle phase pollutants, the PM mass emission factors ranged from 0.31 to 47 g kg-1 dry fuel and the PM number emission factors from 8.5 × 1010 to 2.4 × 1014 particles kg-1 dry fuel, also depending on the appliance and fuel tested. The PSD for all four appliances indicated a well established accumulation mode with evidence of a nucleation mode present for Appliances A and B. The average median aerodynamic particle diameters observed for the four appliances ranged from 84 to 187 nm while burning red oak or pellets. In general, the pellet-burning appliance had the highest overall operating efficiency and lowest emissions of the four units tested.

  5. Analysis of Potassium Superoxide/Kerosene Situation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. S. Bullock

    2001-01-16

    A general picture of the processes that could occur in an initiated KO{sub 2}-kerosene reaction with excess kerosene and in contact with K metal has been created. A worst-case estimate of explosion of the dispersed kerosene overlayer has also been created, with a probable value of average pressure surge in the current storage room of less than 0.4 psi. more probable scenarios would put the peak value of pressure surge somewhat lower, with ignition of the K metal and burning of the excess kerosene at a rate between smooth burning and a slow deflagration. The enthalpy release from the combustionmore » of kerosene in this situation 9478,440 cal is much larger than that for the reaction between KO{sub 2} and kerosene (between 2346 and 4589 cal). Thus, kerosene combustion is potentially much more significant than the KO{sub 2} reaction and may provide 99.05 to 99.51% of the total energy of possible explosions. Hence, there is a good reason to separate bulk amounts of flammable or combustible hydrocarbons from explosive material. For this case, in the limit that absolutely all hydrocarbons were removed from the system, there should no longer be an explosive hazard.« less

  6. Fuel oil and kerosene sales 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-09-01

    This publication contains the 1995 survey results of the ``Annual Fuel Oil and Kerosene Sales Report`` (Form EIA-821). This is the seventh year that the survey data have appeared in a separate publication. Except for the kerosene and on-highway diesel information, data presented in Tables 1 through 12 (Sales of Fuel Oil and Kerosene) present results of the EIA-821 survey. Tables 13 through 24 (Adjusted Sales of Fuel Oil and Kerosene) include volumes that are based on the EIA-821 survey but have been adjusted to equal the product supplied volumes published in the Petroleum Supply Annual (PSA). 24 tabs.

  7. JPS heater and sensor lightning qualification

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1989-01-01

    Simulated lightning strike testing of the Redesigned Solid Rocket Motor (RSRM) field joint protection system heater assembly was performed at Thiokol Corp., Wendover Lightning Facility. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of heater cable transients on cables within the systems tunnel. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by transients from all cables external to the systems tunnel, was 92 amperes. The maximum open-circuit voltage coupled was 316 volts. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by heater power cable transients only, was 2.7 amperes; the maximum open-circuit voltage coupled was 39 volts. All heater power cable induced coupling was due to simulated lightning discharges only, no heater operating power was applied during the test. The results showed that, for a worst-case lightning discharge, the heater power cable is responsible for a 3.9 decibel increase in voltage coupling to operational flight cables within the systems tunnel. Testing also showed that current and voltage levels coupled onto cables within the systems tunnel are partially dependant on the relative locations of the cables within the systems tunnel.

  8. Assessment of exposure to indoor air contaminants from combustion sources: methodology and application.

    PubMed

    Leaderer, B P; Zagraniski, R T; Berwick, M; Stolwijk, J A

    1986-08-01

    A methodology for assessing indoor air pollutant exposures is presented, with specific application to unvented combustion by-products. This paper describes the method as applied to a study of acute respiratory illness associated with the use of unvented kerosene space heaters in 333 residences in the New Haven, Connecticut, area from September 1982 to April 1983. The protocol serves as a prototype for a nested design of exposure assessment which could be applied to large-scale field studies of indoor air contaminant levels. Questionnaires, secondary records, and several methods of air monitoring offer a reliable method of estimating environmental exposures for assessing associations with health effects at a reasonable cost. Indoor to outdoor ratios of NO2 concentrations were found to be 0.58 +/- 0.31 for residences without known sources of NO2. Levels of NO2 were found to be comparable for homes with a kerosene heater only and those with a gas cooking stove only. Homes with a kerosene heater and a gas stove had average two-week NO2 levels approximately double those with only one source. Presence of tobacco smokers had a small but significant impact on indoor NO2 levels. Two-week average levels of indoor NO2 were found to be excellent predictors of total personal NO2 exposure for a small sample of adults. Residences with kerosene space heaters had SO2 levels corresponding to the number of hours of heater use and the sulfur content of the fuel. Formaldehyde levels were found to be low and not related to unvented combustion sources. NO2, SO2, and CO2 levels measured in some of the residences were found to exceed those levels specified in current national health standards.

  9. Fuel oil and kerosene sales 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-10-03

    This publication contains the 1993 survey results of the ``Annual Fuel Oil and Kerosene, Sales Report`` (Form EIA-821). This is the fifth year that the survey data have appeared in a separate publication. Prior to the 1989 report, the statistics appeared in the Petroleum Marketing Annual (PMA) for reference year 1988 and the Petroleum Marketing Monthly (PMM) for reference years 1984 through 1987. The 1993 edition marks the 10th annual presentation of the results of the ongoing ``Annual Fuel Oil and Kerosene Sales Report`` survey. Except for the kerosene and on-highway diesel information, data presented in Tables 1 through 12more » (Sales of Fuel Oil and Kerosene) present results of the EIA-821 survey. Tables 13 through 24 (Adjusted Sales of Fuel Oil and Kerosene) include volumes that are based on the EIA-821 survey but have been adjusted to equal the products supplied volumes published in the Petroleum Supply Annual (PSA).« less

  10. Fuel oil and kerosene sales 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-10-29

    This publication contains the 1992 survey results of the ``Annual Fuel Oil and Kerosene Sales Report`` (Form EIA-821). This is the fourth year that the survey data have appeared in a separate publication. Prior to the 1989 report, the statistics appeared in the Petroleum Marketing Annual (PMA) for reference year 1988 and the Petroleum Marketing Monthly (PMM for reference years 1984 through 1987. The 1992 edition marks the ninth annual presentation of the results of the ongoing ``Annual Fuel Oil and Kerosene Sales Report`` survey. Except for the kerosene and on-highway diesel information, data presented in Tables 1 through 12more » (Sales of Fuel Oil and Kerosene) present results of the EIA-821 survey. Tables 13 through 24 (Adjusted Sales of Fuel Oil and Kerosene) include volumes that are based on the EIA-821 survey but have been adjusted to equal the products supplied volumes published in the Petroleum Supply Annual (PSA).« less

  11. Thermophysics Characterization of Kerosene Combustion

    NASA Technical Reports Server (NTRS)

    Wang, Ten-See

    2000-01-01

    A one-formula surrogate fuel formulation and its quasi-global combustion kinetics model are developed to support the design of injectors and thrust chambers of kerosene-fueled rocket engines. This surrogate fuel model depicts a fuel blend that properly represents the general physical and chemical properties of kerosene. The accompanying gaseous-phase thermodynamics of the surrogate fuel is anchored with the heat of formation of kerosene and verified by comparing a series of one-dimensional rocket thrust chamber calculations. The quasi-global combustion kinetics model consists of several global steps for parent fuel decomposition, soot formation, and soot oxidation, and a detailed wet-CO mechanism. The final thermophysics formulations are incorporated with a computational fluid dynamics model for prediction of the combustor efficiency of an uni-element, tri-propellant combustor and the radiation of a kerosene-fueled thruster plume. The model predictions agreed reasonably well with those of the tests.

  12. Remote Sensing of Forest Fires from Space

    NASA Technical Reports Server (NTRS)

    Kaufman, Y.

    1999-01-01

    Forest fires, and fires used for deforestation and agriculture are sporadic. Some may last an hour others several days. It is difficult to find the fires or to estimate their effect on atmospheric pollution without an "eye in the sky" a satellite or an array of satellites that monitors them routinely from space. Since fires have a significant effect on the quality of air that we breath, on the surface vegetation, on clouds and precipitation and even on climate, NASA and other space agencies try to develop fire monitoring capability from space. Presently satellites were not designed to monitor fires. But the AVHRR and GOES satellites were used for fire monitoring. AVHRR is an orbiter that passes over the same area twice a day with detailed observations of fires from a distance of 800 km, GOES is a stationary satellite located above the equator, and observes the larger fires from a distance of 20,000 km. Field experiments, such as the "SCAR-B" experiment in Brazil conducted in 1995 by INPE, NASA and Universities of Sao Paulo, Washington and Wisconsin, were used to determine the ability of satellites to observe fires and the emitted pollution. They are the basis of a new system of satellites designed by NASA to observe fires and pollution, the Earth Observing System AM1 and PM1. NASA plans to use the information for four observations a day of the fires and the emitted smoke. The information can be used to determine the location of the fires, to distinguish between small and large fires and monitor their development. The satellites will measure the emitted smoke and with trajectory models can be used to predict the density and spread of the smoke.

  13. Effects of Cavity Configurations on Flameholding and Performances of Kerosene Fueled Scramjet Combustor

    NASA Astrophysics Data System (ADS)

    Shi, Deyong; Song, Wenyan; Wang, Yuhang; Wang, Yanhua

    2017-08-01

    In this work, the effects of cavity flameholder configurations on flameholding and performances of kerosene fueled scramjet combustor were studied experimentally and numerically. For experiments, a directly connected ground facility was used and clean high enthalpy air, with a total temperature of 800 K and a total pressure of 800 Kpa, was provided by an electricity resistance heater. To investigate the effects of cavity configurations on flameholding capacity and reacting-flow characteristics, three different flameholders, one single cavity flameholder and two tandem cavity flameholders, were used in experiments. For the two combustors with tandem cavity flameholders, the location and configurations of its up-stream cavity were same with the single cavity flameholder, and the length-to-depth ratios for down-stream cavities were 9 and 11 respectively. The experimental results showed that stabilize kerosene combustion were achieved for combustor with tandem cavity flameholders mounted, and none for that with single cavity flameholder. The none-reacting and reacting flows of combustor models with tandem cavity flameholders were compared and studied with numerical and experimental results. The results showed that higher combustion efficiencies and pressure recovery ratios were achieved for the combustor with down-stream cavity length-to-depth ratio of 9.

  14. A preliminary test method for masonry heater particulate matter and carbon monoxide emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stern, C.H.; Jaasma, D.R.; Shelton, J.W.

    1991-08-01

    A test method for determining carbon monoxide (CO) and particulate matter (PM) emissions from masonry heaters is described and results of tests on two masonry heaters are presented. The method specifies fueling protocol and laboratory measurement procedures for determination of both emission factors (g/kg) and rates (g/hr). The fuel load size and fueling intervals are dependent upon the firebox volume of the masonry heater. The test method starts with a room temperature masonry heater and involves five firings to achieve burn rates in two ranges, where the burn rate is defined as the dry mass of the fuel load dividedmore » by the time between loadings. Emission samples are extracted from a dilution tunnel with a set flow rate and configuration. Particulate matter sampling is similar to US EPA Method 5G for woodstoves, and Co concentration is measured by a nondispersive infrared (NDIR) gas analyzer. The emissions results for each firing are weighted according to EPA Method 28 to obtain the overall emission totals for the test.« less

  15. Thermophysics Characterization of Kerosene Combustion

    NASA Technical Reports Server (NTRS)

    Wang, Ten-See

    2001-01-01

    A one-formula surrogate fuel formulation and its quasi-global combustion kinetics model are developed to support the design of injectors and thrust chambers of kerosene-fueled rocket engines. This surrogate fuel model depicts a fuel blend that properly represents the general physical and chemical properties of kerosene. The accompanying gaseous-phase thermodynamics of the surrogate fuel is anchored with the heat of formation of kerosene and verified by comparing a series of one-dimensional rocket thrust chamber calculations. The quasi-global combustion kinetics model consists of several global steps for parent fuel decomposition, soot formation, and soot oxidation and a detailed wet-CO mechanism to complete the combustion process. The final thermophysics formulations are incorporated with a computational fluid dynamics model for prediction of the combustion efficiency of an unielement, tripropellant combustor and the radiation of a kerosene-fueled thruster plume. The model predictions agreed reasonably well with those of the tests.

  16. Confined space emergency response: assessing employer and fire department practices.

    PubMed

    Wilson, Michael P; Madison, Heather N; Healy, Stephen B

    2012-01-01

    An emergency response plan for industrial permit-required confined space entry is essential for employee safety and is legally required. Maintaining a trained confined space rescue team, however, is costly and technically challenging. Some employers turn to public fire departments to meet their emergency response requirements. The confined space emergency response practices of employers and fire departments have not been previously assessed. We present (1) federal data on the U.S. occurrence between 1992 and 2005 of confined space fatal incidents involving toxic and/or oxygen-deficient atmospheres; (2) survey data from 21 large companies on permit-required confined space emergency response practices; (3) data on fire department arrival times; and (4) estimates by 10 senior fire officers of fire department rescue times for confined space incidents. Between 1992 and 2005, 431 confined space incidents that met the case definition claimed 530 lives, or about 0.63% of the 84,446 all-cause U.S. occupational fatal injuries that occurred during this period. Eighty-seven (20%) incidents resulted in multiple fatalities. Twelve (57%) of 21 surveyed companies reported that they relied on the fire department for permit-required confined space emergency response. Median fire department arrival times were about 5 min for engines and 7 min for technical rescue units. Fire department confined space rescue time estimates ranged from 48 to 123 min and increased to 70 and 173 min when hazardous materials were present. The study illustrates that (1) confined space incidents represent a small but continuing source of fatal occupational injuries in the United States; (2) a sizeable portion of employers may be relying on public fire departments for permit-required confined space emergency response; and (3) in the event of a life-threatening emergency, fire departments usually are not able to effect a confined space rescue in a timely manner. We propose that the appropriate role for the

  17. 27 CFR 21.114 - Kerosene.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Kerosene. 21.114 Section 21.114 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF... Kerosene. (a) Distillation range. (For applicable ASTM method, see 1980 Annual Book of ASTM Standards, Part...

  18. 27 CFR 21.114 - Kerosene.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Kerosene. 21.114 Section 21.114 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF... Kerosene. (a) Distillation range. (For applicable ASTM method, see 1980 Annual Book of ASTM Standards, Part...

  19. 27 CFR 21.114 - Kerosene.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Kerosene. 21.114 Section 21.114 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF... Kerosene. (a) Distillation range. (For applicable ASTM method, see 1980 Annual Book of ASTM Standards, Part...

  20. 27 CFR 21.114 - Kerosene.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Kerosene. 21.114 Section 21.114 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF... Kerosene. (a) Distillation range. (For applicable ASTM method, see 1980 Annual Book of ASTM Standards, Part...

  1. 27 CFR 21.114 - Kerosene.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Kerosene. 21.114 Section 21.114 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF... Kerosene. (a) Distillation range. (For applicable ASTM method, see 1980 Annual Book of ASTM Standards, Part...

  2. Fuel oil and kerosene sales 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-08-01

    The Fuel Oil and Kerosene Sales 1996 report provides information, illustrations and State-level statistical data on end-use sales of kerosene; No. 1, No. 2, and No. 4 distillate fuel oil; and residual fuel oil. State-level kerosene sales include volumes for residential, commercial, industrial, farm, and all other uses. State-level distillate sales include volumes for residential, commercial, industrial, oil company, railroad, vessel bunkering, military, electric utility, farm, on-highway, off highway construction, and other uses. State-level residual fuel sales include volumes for commercial, industrial, oil company, vessel bunkering, military, electric utility, and other uses. The Petroleum Marketing Division, Office of Oil andmore » Gas, Energy Information Administration ensures the accuracy, quality, and confidentiality of the published data in the Fuel Oil and Kerosene Sales 1996. 24 tabs.« less

  3. LOW EMISSION AND HIGH EFFICIENCY RESIDENTIAL PELLET-FIRED HEATERS

    EPA Science Inventory

    The paper gives results of air emissions testing and efficiency testing on new commercially available under-feed and top-feed residential heaters burning hardwood- and softwood-based pellets. The results were compared with data from earlier models. Reductions in air emissions w...

  4. Spacecraft Fire Safety: A Human Space Flight Program Perspective

    NASA Technical Reports Server (NTRS)

    Pedley, Michael D.

    2003-01-01

    This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.

  5. Sources of Combustion Products: An Introduction to Indoor Air Quality

    EPA Pesticide Factsheets

    In addition to environmental tobacco smoke, other sources of combustion products are unvented kerosene and gas space heaters, woodstoves, fireplaces, and gas stoves. The major pollutants released are carbon monoxide, nitrogen dioxide, and particles.

  6. Risks and issues in fire safety on the Space Station

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.

  7. Distribution of kerosene components in rats following dermal exposure.

    PubMed

    Tsujino, Y; Hieda, Y; Kimura, K; Eto, H; Yakabe, T; Takayama, K; Dekio, S

    2002-08-01

    The systemic distribution of kerosene components in blood and tissues was analysed in rats following dermal exposure. Four types of trimethylbenzenes (TMBs) and aliphatic hydrocarbons (AHCs) with carbon numbers 9-16 (C(9)-C(16)) were analysed as major kerosene components by capillary gas chromatography/mass spectrometry (GC/MS). The kerosene components were detected in blood and all tissues after a small piece of cotton soaked with kerosene was applied to the abdominal skin. The amounts of TMBs detected were higher than those of AHCs. Greater increases in TMB levels were found in adipose tissue in an exposure duration-dependent manner. The amounts of TMBs detected were only at trace levels following post-mortem dermal exposure to kerosene. These findings suggest that kerosene components were absorbed percutaneously and distributed to various organs via the blood circulation. Post-mortem or ante-mortem exposure to kerosene could be distinguished when the exposure duration was relatively long. Adipose tissue would seem to be the most useful for estimating the degree of kerosene exposure.

  8. Solubilization of water in water-in-oil microemulsions of kerosene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andheria, A.P.; Bhagwat, S.S.

    1995-04-01

    The incorporation of water into fuels formulated as microemulsions can offer several advantages such as fire resistance, increased flash point, and improved air-fuel contact. To this end, phase equilibria of kerosene microemulsions employing ionic and nonionic surfactants such as sodium di-(2-ethylhexyl) sulfosuccinate (AOT), lauryl diethanolamide (LDEA), nonylphenol EO-4.5 (NPEO-4.5), sorbitan monolaurate (Span-20), and cetyltrimethylammonium bromide (CTAB), as well as cosurfactants such as n-pentanol, n-hexanol, and n-heptanol, were studied. The effect of the aromaticity of the oil phase on the solubilization of water was also investigated.

  9. 40 CFR 65.149 - Boilers and process heaters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... stream is not introduced as or with the primary fuel, a temperature monitoring device in the fire box...-throughput transfer racks, as applicable, shall meet the requirements of this section. (2) The vent stream... thermal units per hour) or greater. (ii) A boiler or process heater into which the vent stream is...

  10. Design Guidelines for Heating Aircraft Hangars with Radiant Heaters.

    DTIC Science & Technology

    1983-12-01

    required for gas-fired radiant heaters. Building mate- rials that are contiguous to the exterior (e.g., glass skylights ) are potential collection points...for use in aircraft hangars * when the burners glow a dull red, a malfunctioning burner would be visually apparent by intermittent burner incandescence

  11. Fuel oil and kerosene sales 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-08-01

    The Fuel Oil and Kerosene Sales 1997 report provides information, illustrations and state-level statistical data on end-use sales of kerosene; No. 1, No. 2, and No. 4 distillate fuel oil; and residual fuel oil. State-level kerosene sales include volumes for residential, commercial, industrial, farm, and all other uses. State-level distillate sales include volumes for residential, commercial, industrial, oil company, railroad, vessel bunkering, military, electric utility, farm, on-highway, off highway construction, and other uses. State-level residual fuel sales include volumes for commercial, industrial, oil company, vessel bunkering, military, electric utility, and other uses. 24 tabs.

  12. The levels of kerosene components in biological samples after repeated dermal exposure to kerosene in rats.

    PubMed

    Fujihara, Junko; Hieda, Yoko; Tsujino, Yoshio; Xue, Yuying; Takayama, Koji; Kimura, Kojiro; Dekio, Satoshi

    2004-04-01

    The current study was experimentally investigated using rats whether or not kerosene components are accumulated from daily repeated dermal exposure. Rats received daily 1h-exposure to kerosene for 5 days (5K), daily 1h-exposure for 4 days and left for 1 day (4KL), a single 1h-exposure (1K), a single 1h-exposure and left for 1 day (1KL), or a single 1h-exposure, sacrificed and left dead for 1 day (1KLD). Kerosene components, trimethylbenzenes (TMBs) and aliphatic hydrocarbons (AHCs) in blood and tissues were determined by GC-MS. In blood, almost the same concentrations of TMBs were detected in the rats sacrificed immediately after exposure (5K, 1K and 1KLD), and only trace levels were detected in the rats sacrificed 1 day after exposure (4 and 1KL). Almost the same levels of AHCs in blood were detected among groups except for the rats sacrificed 1 day after a single exposure (1KL), in which AHCs were slightly lower. These results suggest that (1) AHCs tend to be accumulated from daily exposure, while TMBs do not, (2) the proportions of detected kerosene components in blood can be an indicator of whether the last exposure occurred just before death or not, (3) the kerosene levels last at least 1 day without blood circulation.

  13. Conversion of a Micro, Glow-Ignition, Two-Stroke Engine from Nitromethane-Methanol Blend Fuel to Military Jet Propellant (JP-8)

    DTIC Science & Technology

    2012-01-01

    Table 10-4: Selected Birk polyimide heater sizes, resistances and locations [37] ........................ 79 Table 10-5: Final starting tests with (3...damage, and fire are prevalent. Kerosene type fuels are also cheaper and more common than nitromethane-methanol blend fuels. One final note is...diesel fuel was changed to produce lower emissions, the abrasiveness of diesel fuel increased. This was especially problematic for the new high

  14. 27 CFR 21.115 - Kerosene (deodorized).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Kerosene (deodorized). 21.115 Section 21.115 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU....115 Kerosene (deodorized). (a) Distillation range. No distillate should come over below 340 °F. and...

  15. 27 CFR 21.115 - Kerosene (deodorized).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Kerosene (deodorized). 21.115 Section 21.115 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU....115 Kerosene (deodorized). (a) Distillation range. No distillate should come over below 340 °F. and...

  16. 27 CFR 21.115 - Kerosene (deodorized).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Kerosene (deodorized). 21.115 Section 21.115 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU....115 Kerosene (deodorized). (a) Distillation range. No distillate should come over below 340 °F. and...

  17. 27 CFR 21.115 - Kerosene (deodorized).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Kerosene (deodorized). 21.115 Section 21.115 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU....115 Kerosene (deodorized). (a) Distillation range. No distillate should come over below 340 °F. and...

  18. 27 CFR 21.115 - Kerosene (deodorized).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Kerosene (deodorized). 21.115 Section 21.115 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU....115 Kerosene (deodorized). (a) Distillation range. No distillate should come over below 340 °F. and...

  19. 30 CFR 75.341 - Direct-fired intake air heaters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... combustible materials from passing over the burner units. (e) If intake air heaters use liquefied fuel systems... measurement of the carbon monoxide concentration at the bottom of each shaft, slope, or in the drift opening... a carbon monoxide sensor that is calibrated with a known concentration of carbon monoxide and air at...

  20. 10 CFR Appendix P to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Pool Heaters

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...-1994. The expression of fuel consumption for oil-fired pool heaters shall be in Btu. 4.2Average annual fossil fuel energy for pool heaters. The average annual fuel energy for pool heater, EF, is defined as... of pool operating hours=4464 h QIN=rated fuel energy input as defined according to 2.9.1 or 2.9.2 of...

  1. 40 CFR 80.525 - What requirements apply to kerosene blenders?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false What requirements apply to kerosene....525 What requirements apply to kerosene blenders? (a) For purposes of this subpart, a kerosene blender means any refiner who produces NRLM or motor vehicle diesel fuel by adding kerosene to NRLM or motor...

  2. 40 CFR 80.525 - What requirements apply to kerosene blenders?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false What requirements apply to kerosene....525 What requirements apply to kerosene blenders? (a) For purposes of this subpart, a kerosene blender means any refiner who produces NRLM or motor vehicle diesel fuel by adding kerosene to NRLM or motor...

  3. 40 CFR 80.525 - What requirements apply to kerosene blenders?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false What requirements apply to kerosene....525 What requirements apply to kerosene blenders? (a) For purposes of this subpart, a kerosene blender means any refiner who produces NRLM or motor vehicle diesel fuel by adding kerosene to NRLM or motor...

  4. 40 CFR 80.525 - What requirements apply to kerosene blenders?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false What requirements apply to kerosene....525 What requirements apply to kerosene blenders? (a) For purposes of this subpart, a kerosene blender means any refiner who produces NRLM or motor vehicle diesel fuel by adding kerosene to NRLM or motor...

  5. 40 CFR 80.525 - What requirements apply to kerosene blenders?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false What requirements apply to kerosene....525 What requirements apply to kerosene blenders? (a) For purposes of this subpart, a kerosene blender means any refiner who produces NRLM or motor vehicle diesel fuel by adding kerosene to NRLM or motor...

  6. Biodegradation of kerosene by Aspergillus ochraceus NCIM-1146.

    PubMed

    Saratale, Ganesh; Kalme, Satish; Bhosale, Sanjyot; Govindwar, Sanjay

    2007-10-01

    The filamentous fungus Aspergillus ochraceus NCIM-1146 was found to degrade kerosene, when previously grown mycelium (96 h) was incubated in the broth containing kerosene. Higher levels of NADPH-DCIP reductase, aminopyrine N-demethylase and kerosene biodegradation activities were found to be present after the growth in potato dextrose broth for 96 h, when compared with the activities at different time intervals during the growth phase. NADPH was the preferred cofactor for enzyme activity, which was inhibited by CO, indicating cytochrome P450 mediated reactions. A significant increase in all the enzyme activities was observed when mycelium incubated for 18 h in mineral salts medium, containing cholesterol, camphor, naphthalene, 1,2-dimethoxybenzene, phenobarbital, n-hexane, kerosene or saffola oil as inducers. Acetaldehyde produced by alcohol dehydrogenase could be used as an indicator for the kerosene biodegradation.

  7. Design of an Improved Heater Array to Measure Microscale Wall Heat Transfer

    NASA Technical Reports Server (NTRS)

    Kim, Jungho; Chng, Choon Ping; Kalkur, T. S.

    1996-01-01

    An improved array of microscale heaters is being developed to measure the heat transfer coefficient at many points underneath individual bubbles during boiling as a function of space and time. This heater array enables the local heat transfer from a surface during the bubble growth and departure process to be measured with very high temporal and spatial resolution, and should allow better understanding of the boiling heat transfer mechanisms by pin-pointing when and where in the bubble departure cycle large amounts of wall heat transfer occur. Such information can provide much needed data regarding the important heat transfer mechanisms during the bubble departure cycle, and can serve as benchmarks to validate many of the analytical and numerical models used to simulate boiling. The improvements to the heater array include using a silicon-on-quartz substrate to reduce thermal cross-talk between the heaters, decreased space between the heaters, increased pad sizes on the heaters, and progressive heater sizes. Some results using the present heater array are discussed.

  8. Structural Benchmark Testing for Stirling Convertor Heater Heads

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Kalluri, Sreeramesh; Bowman, Randy R.

    2007-01-01

    The National Aeronautics and Space Administration (NASA) has identified high efficiency Stirling technology for potential use on long duration Space Science missions such as Mars rovers, deep space missions, and lunar applications. For the long life times required, a structurally significant design limit for the Stirling convertor heater head is creep deformation induced even under relatively low stress levels at high material temperatures. Conventional investigations of creep behavior adequately rely on experimental results from uniaxial creep specimens, and much creep data is available for the proposed Inconel-718 (IN-718) and MarM-247 nickel-based superalloy materials of construction. However, very little experimental creep information is available that directly applies to the atypical thin walls, the specific microstructures, and the low stress levels. In addition, the geometry and loading conditions apply multiaxial stress states on the heater head components, far from the conditions of uniaxial testing. For these reasons, experimental benchmark testing is underway to aid in accurately assessing the durability of Stirling heater heads. The investigation supplements uniaxial creep testing with pneumatic testing of heater head test articles at elevated temperatures and with stress levels ranging from one to seven times design stresses. This paper presents experimental methods, results, post-test microstructural analyses, and conclusions for both accelerated and non-accelerated tests. The Stirling projects use the results to calibrate deterministic and probabilistic analytical creep models of the heater heads to predict their life times.

  9. Effects and mechanisms of kerosene use-related toxicity.

    PubMed

    Maiyoh, Geoffrey K; Njoroge, Rachel W; Tuei, Vivian C

    2015-07-01

    Kerosene is a heterogeneous hydrocarbon substance that continues to find many uses worldwide due to its economic viability and ease of availability. In spite of kerosene's many uses, it is known to cause harm to various body organs and systems. Major affected body organs/systems are the pulmonary system, central nervous system, cardiovascular system, the skin, immune system and liver. This review discusses the various kerosene-mediated adverse health effects and possible mechanisms by which kerosene is likely to inflict such effects. These mechanisms are quite varied and include induction of inflammation, loss of effectiveness of pulmonary surfactants, hypoxia, production of highly reactive oxidative metabolites, extraction of endogenous epidermal and membrane lipids, necrosis, hormonal and enzymatic levels changes, and immunosuppression. Understanding of the above will allow for proper relevant policy formulation and targeted kerosene-mediated morbidity and mortality preventive and management initiatives. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Clinical profile of children with kerosene aspiration.

    PubMed

    Venkatesh, C; Sriram, P; Adhisivam, B; Mahadevan, S

    2011-07-01

    Accidental aspiration of kerosene is a common problem among children in developing countries. This descriptive study involved the retrospective analysis of children admitted with kerosene aspiration in a tertiary care hospital in South India for a year. Kerosene aspiration contributed to 60.4% of poisoning cases. Boys aged less than three years and from a rural background formed a significant proportion. Tachypnoea, cough and crepitations were the predominant clinical findings. Male gender and malnutrition (weight for age <80%) were significantly associated with prolonged hospital stay.

  11. Gravity and Heater Size Effects on Pool Boiling Heat Transfer

    NASA Technical Reports Server (NTRS)

    Kim, Jungho; Raj, Rishi

    2014-01-01

    The current work is based on observations of boiling heat transfer over a continuous range of gravity levels between 0g to 1.8g and varying heater sizes with a fluorinert as the test liquid (FC-72/n-perfluorohexane). Variable gravity pool boiling heat transfer measurements over a wide range of gravity levels were made during parabolic flight campaigns as well as onboard the International Space Station. For large heaters and-or higher gravity conditions, buoyancy dominated boiling and heat transfer results were heater size independent. The power law coefficient for gravity in the heat transfer equation was found to be a function of wall temperature under these conditions. Under low gravity conditions and-or for smaller heaters, surface tension forces dominated and heat transfer results were heater size dependent. A pool boiling regime map differentiating buoyancy and surface tension dominated regimes was developed along with a unified framework that allowed for scaling of pool boiling over a wide range of gravity levels and heater sizes. The scaling laws developed in this study are expected to allow performance quantification of phase change based technologies under variable gravity environments eventually leading to their implementation in space based applications.

  12. EDUCATION LEVEL IS GREATEST RISK-FACTOR IN CARBON MONOXIDE POISONING

    EPA Science Inventory

    Carbon monoxide (CO) is a toxic by-product of the combustion of fossil fuels. In confined spaces, inefficient combustion sources, such as furnaces, stoves, kerosene heaters and automobiles can generate levels of CO that interrupt oxygen transport throughout the body, potentially ...

  13. Experiments to ensure Space Station fire safety - A challenge

    NASA Technical Reports Server (NTRS)

    Youngblood, W. W.; Seiser, K. M.

    1988-01-01

    Three experiments have been formulated in order to address prominent fire safety requirements aboard the NASA Space Shuttle; these experiments are to be conducted as part of a Space Station-based Technology Development Mission for the growth phase of Space Station construction and operation. The experiments are: (1) an investigation of the flame-spread rate and combustion-product evolution in the burning of typical spacecraft materials in low gravity; (2) an evaluation of the interaction of fires and candidate fire extinguishers in low gravity; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion in low gravity.

  14. Architecture for Absorption Based Heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moghaddam, Saeed; Chugh, Devesh

    An absorption based heater is constructed on a fluid barrier heat exchanging plate such that it requires little space in a structure. The absorption based heater has a desorber, heat exchanger, and absorber sequentially placed on the fluid barrier heat exchanging plate. The vapor exchange faces of the desorber and the absorber are covered by a vapor permeable membrane that is permeable to a refrigerant vapor but impermeable to an absorbent. A process fluid flows on the side of the fluid barrier heat exchanging plate opposite the vapor exchange face through the absorber and subsequently through the heat exchanger. Themore » absorption based heater can include a second plate with a condenser situated parallel to the fluid barrier heat exchanging plate and opposing the desorber for condensation of the refrigerant for additional heating of the process fluid.« less

  15. Implementation of heaters on thermally actuated spacecraft mechanisms

    NASA Technical Reports Server (NTRS)

    Busch, John D.; Bokaie, Michael D.

    1994-01-01

    This paper presents general insight into the design and implementation of heaters as used in actuating mechanisms for spacecraft. Problems and considerations that were encountered during development of the Deep Space Probe and Science Experiment (DSPSE) solar array release mechanism are discussed. Obstacles included large expected fluctuations in ambient temperature, variations in voltage supply levels outgassing concerns, heater circuit design, materials selection, and power control options. Successful resolution of these issues helped to establish a methodology which can be applied to many of the heater design challenges found in thermally actuated mechanisms.

  16. Mountain Plains Learning Experience Guide: Appliance Repair. Course: Heater-Type Appliances.

    ERIC Educational Resources Information Center

    Ziller, T.

    One of two individualized courses included in an appliance repair curriculum (see CE 027 767), this course covers minor and major heater-type appliances. The course is comprised of six units: (1) Irons, (2) Roasters, (3) Space Heaters, (4) Water Heaters, (5) Electric Ranges, and (6) Gas Ranges. Each unit begins with a Unit Learning Experience…

  17. An Unusual Case of Suicide Attempt Using Intravenous Injection of Kerosene.

    PubMed

    Hasan, M N; Sutradhar, S R; Ahmed, S M; Chowdhury, I H

    2016-07-01

    Kerosene belongs to the hydrocarbon group of compounds, used as a fuel for lamps, as well as heating and cooking in developing countries. Accidental kerosene poisoning and intoxication usually occur by inhalation or by occupational percutaneous absorption. Adults usually ingest kerosene for the purpose of self-harm, and children may ingest accidentally. Suicidal attempt using intravenous kerosene is an extra ordinary and very rare occurrence. A very few data are available regarding effects of intravenous administration of kerosene and its management.

  18. Merox catalyst innovation solves difficult kerosene treating problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Verachtert, T.A.; Salazar, J.R.; Staehle, B.E.

    1985-03-01

    The UOP* Merox* process has enjoyed more than 25 years of successful commercial application. It is applied to treatment of mercaptanrich hydrocarbon streams ranging from a light gas to liquids as heavy as 350/sup 0/C (650/sup 0/F) endpoint diesel fuel. Although Merox has been applied successfully to many kerosenes, there are kerosenes from certain crudes that could not be treated using the standard Merox system. Recent UOP Merox research has centered on the development of new catalysts. From this research, an improved catalyst system (Merox 10*) for kerosene treatment now makes the Merox process applicable to the sweetening of anymore » kerosene boiling range material from any crude oil source now in production. This Merox catalyst innovation also could replace the more expensive hydrotreating still being used by refiners for reducing the mercaptan content of distillates. This paper discusses the application of the Merox process to the treatment of higher boiling fuels, particularly kerosene and jet fuel; however, it should be understood that the treatment of illuminating kerosene, stove oil, diesel fuel, and light furnace oil is quite similar although generally less complicated. Comparative economics and commercial data are provided for the Merox 10 and conventional fixed bed Merox systems. The well established superior economics of Merox over an equivalent duty hydrotreater are presented.« less

  19. Additives for Water Mist Fire Suppression Systems: A Review

    DTIC Science & Technology

    2012-11-01

    TM 2012-236; R & D pour la défense Canada – Atlantique; novembre 2012. Introduction : On utilisait les halons comme agents extincteurs dans les... 13 Table 11: Results of fire extinguishment tests on kerosene or heptanes pan fires using water mist and water mist with 2 vol...Forafac® WM. ....................................................... 13 x DRDC Atlantic TM 2012-236 This page intentionally left

  20. Burns and fires in South Africa's informal settlements: Have approved kerosene stoves improved safety?

    PubMed

    Kimemia, David; van Niekerk, Ashley; Govender, Rajen; Seedat, Mohamed

    2018-06-01

    This study is a follow-on to an intervention project that implemented South African Bureau of Standards approved kerosene stoves and safety education in 150 households of a Johannesburg informal settlement. An investigation conducted 12 months later established that 43 stoves had operational defects, yet 23 households continued using the faulty appliances. This study focuses on (1) the psychological and behavioural factors associated with continued use of faulty stoves by the 23 households, and (2), the specific technical failures of these stoves. The study involved one-on-one recall interviews with the households using defective stoves (N=21) and laboratory-based stove tests for seven of the affected appliances. The results indicate that the stoves had defects in critical safety features such as flame control and the self-extinguishing mechanism. Four stove malfunctions of minor burn affect were reported in the study. Continued use of the damaged stoves was significantly associated with the time from receipt of the stove to detection of first failure: stoves that failed later on were more significantly likely to remain in use as compared to those that failed sooner. The findings point to the need for strengthening enforcement of appliance standards, public education on kerosene stove use, and structural change for the energy-poor. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  1. Fuel Oil and Kerosene Sales

    EIA Publications

    2016-01-01

    Provides information, illustrations and state-level statistical data on end-use sales of kerosene; No.1, No. 2, and No. 4 distillate fuel oil; and residual fuel oil. State-level kerosene sales include volumes for residential, commercial, industrial, farm, and all other uses. State-level distillate sales include volumes for residential, commercial, industrial, oil company, railroad, vessel bunkering, military, electric utility, farm, on-highway, off-highway construction, and other uses. State-level residual fuel sales include volumes for commercial, industrial, oil company, vessel bunkering, military, electric utility, and other uses.

  2. Kerosene lamp "Kupi": lights the house, but may bring darkness to life.

    PubMed

    Ahmed, S; Hussain, M; Rahman, A; Halim, A; Rahman, F

    2009-07-01

    In terms of mortality and morbidity, childhood burn comprises a significant public health problem in Bangladesh, especially in rural poor families who use kerosene-lamp "Kupi" for lighting and traditional mud-made open oven for cooking. They lack optimum safety measures. A total of 100 patients in the age group of 01 to 15 years who got admitted into the burn unit of Dhaka Medical College Hospital during the first half of 2005 were enrolled in the study. Data on socio-demographic variables and information on events and consequences of burn were extracted and analyzed. The results identified flame burn from kerosene lamp "Kupi" as the major cause and source of burn in affected children. Both electrical burn and burn by ash were seen to happen in older male and toddler boys respectively. There were 02 deaths in the series; both were females and were the victims of massive flame burn-one from Kupi and other form oven fire during cooking. Pediatric burn imposes stress on the physique, psyche and socio-economic status of the affected personnel and families. Effective measures are needed to prevent this unfortunate injury in children which is preventable to a large extent.

  3. 26 CFR 48.4082-7 - Kerosene; exemption for feedstock purposes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Kerosene; exemption for feedstock purposes. 48..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-7 Kerosene; exemption for feedstock purposes. (a... kerosene for use for a feedstock purpose. (b) Definitions. The following definitions apply to this section...

  4. 26 CFR 48.4082-7 - Kerosene; exemption for feedstock purposes.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Kerosene; exemption for feedstock purposes. 48..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-7 Kerosene; exemption for feedstock purposes. (a... kerosene for use for a feedstock purpose. (b) Definitions. The following definitions apply to this section...

  5. 26 CFR 48.4082-7 - Kerosene; exemption for feedstock purposes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Kerosene; exemption for feedstock purposes. 48..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-7 Kerosene; exemption for feedstock purposes. (a... kerosene for use for a feedstock purpose. (b) Definitions. The following definitions apply to this section...

  6. 26 CFR 48.4082-7 - Kerosene; exemption for feedstock purposes.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Kerosene; exemption for feedstock purposes. 48..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-7 Kerosene; exemption for feedstock purposes. (a... kerosene for use for a feedstock purpose. (b) Definitions. The following definitions apply to this section...

  7. Bioremediation of kerosene I: A case study in liquid media.

    PubMed

    Gouda, Mona K; Omar, Sanaa H; Chekroud, Zohra A; Nour Eldin, Hemdan M

    2007-11-01

    The ability of different local isolates in addition to some isolates from Germany to degrade kerosene in liquid medium was studied. The results showed that the percent of kerosene degradation varied among the different organisms and that 59-94% of kerosene was degraded after 21d. Two local isolates (Pseudomonas sp. AP and Pseudomonas sp. CK) and one German isolate (Gordonia sp. DM) were selected for this study. The addition of wheat bran, as co-substrate, stimulated the kerosene degradation by the two local strains, while glucose inhibited the degradation rate using the three organisms with different rates. Ammonium nitrate and urea was the best nitrogen sources. The use of superphosphate (as phosphorus source) in the presence of urea stimulates the degradation rate. It was also observed that the addition of 1% surfactants, like Triton X-100, Igepal, Tergitol, or Tween 20 and 80 enhanced the kerosene degradation. The degradation percent lied between 94% and 98%. The ability of the tested organisms to degrade kerosene concentration from 2% to 8% was evaluated. It was found that the three organisms degraded about 65-85% from 8% kerosene after 21d. The use of rice straw-immobilized cells reduced the time of degradation and enhanced the degradation ability of the organisms. The sodium dodecyl sulphate-polyacrylamide gel electrophoresis revealed the presence of a common protein band when the tested organisms were grown on kerosene.

  8. 26 CFR 48.4082-5 - Diesel fuel and kerosene; Alaska.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; Alaska. 48.4082-5..., and Taxable Fuel Taxable Fuel § 48.4082-5 Diesel fuel and kerosene; Alaska. (a) Application. This section applies to diesel fuel or kerosene removed, entered, or sold in Alaska for ultimate sale or use in...

  9. 26 CFR 48.4082-5 - Diesel fuel and kerosene; Alaska.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; Alaska. 48.4082-5..., and Taxable Fuel Taxable Fuel § 48.4082-5 Diesel fuel and kerosene; Alaska. (a) Application. This section applies to diesel fuel or kerosene removed, entered, or sold in Alaska for ultimate sale or use in...

  10. 26 CFR 48.4082-5 - Diesel fuel and kerosene; Alaska.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; Alaska. 48.4082-5..., and Taxable Fuel Taxable Fuel § 48.4082-5 Diesel fuel and kerosene; Alaska. (a) Application. This section applies to diesel fuel or kerosene removed, entered, or sold in Alaska for ultimate sale or use in...

  11. 26 CFR 48.4082-5 - Diesel fuel and kerosene; Alaska.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; Alaska. 48.4082-5..., and Taxable Fuel Taxable Fuel § 48.4082-5 Diesel fuel and kerosene; Alaska. (a) Application. This section applies to diesel fuel or kerosene removed, entered, or sold in Alaska for ultimate sale or use in...

  12. Semivolatile and Volatile Organic Compound Emissions from Wood-Fired Hydronic Heaters

    EPA Science Inventory

    Four commercially available HH technologies were studied: a single-stage combustor with natural updraft, a three-stage downdraft combustion system, a bottom-fed pellet burner, and a two-stage heater with both a combustion and gasification chamber. The fuel consisted of three wood...

  13. Infrared transparent graphene heater for silicon photonic integrated circuits.

    PubMed

    Schall, Daniel; Mohsin, Muhammad; Sagade, Abhay A; Otto, Martin; Chmielak, Bartos; Suckow, Stephan; Giesecke, Anna Lena; Neumaier, Daniel; Kurz, Heinrich

    2016-04-18

    Thermo-optical tuning of the refractive index is one of the pivotal operations performed in integrated silicon photonic circuits for thermal stabilization, compensation of fabrication tolerances, and implementation of photonic operations. Currently, heaters based on metal wires provide the temperature control in the silicon waveguide. The strong interaction of metal and light, however, necessitates a certain gap between the heater and the photonic structure to avoid significant transmission loss. Here we present a graphene heater that overcomes this constraint and enables an energy efficient tuning of the refractive index. We achieve a tuning power as low as 22 mW per free spectral range and fast response time of 3 µs, outperforming metal based waveguide heaters. Simulations support the experimental results and suggest that for graphene heaters the spacing to the silicon can be further reduced yielding the best possible energy efficiency and operation speed.

  14. Fire safety design considerations for advanced space vehicles

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The desire to understand and explore space has driven man to overcome the confines of the Earth's atmosphere and accept the challenge of spaceflight. With our increasing ability to travel, work, and explore in space comes a need for a better understanding of the hazards in this relatively new endeavor. One of the most important and immediate needs is to be able to predict the ignition, spread, and growth of fire on board spacecraft. Fire safety aboard spacecraft has always been a concern; however, with the increasing number and duration of proposed missions, it is imperative that the spacecraft be designed with a solid understanding of fire hazards, insuring that all risks have been minimized and extinguishment systems are available.

  15. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  16. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  17. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  18. Characterization of kerosene distribution around the ignition cavity in a scramjet combustor

    NASA Astrophysics Data System (ADS)

    Li, Xipeng; Liu, Weidong; Pan, Yu; Yang, Leichao; An, Bin; Zhu, Jiajian

    2017-05-01

    Kerosene distribution before its ignition in a scramjet combustor with dual cavity was measured using kerosene-PLIF under transverse injection upstream of the cavity and different injection pressures. The simulated flight condition is Ma 5.5, and the isolator entrance has a Mach number of 2.52, a total pressure of 1.6 MPa and a stagnation temperature of 1486 K. Effects of injection pressure on fuel distribution characteristics were analyzed. The majority of kerosene is present in the cavity shear layer as well as its upper region. Kerosene extends gradually into the cavity, almost, at a constant angle. Large scale structures are evident on the windward side of kerosene. The cavity shear layer plays an important role in determining the kerosene distribution and its entrainment into the cavity. The middle part of cavity is the most suitable location for ignition as a result of a favorable local equivalent ratio. As the injection pressure increases, the penetration height gets higher with the rate of increase getting slower at higher injection pressure. Meanwhile, the portion of kerosene entrained into cavity through shear layer becomes smaller as injection pressure increases. However, the kerosene entrained into cavity still increase due to the increased mass flow rate of kerosene.

  19. Numerical Investigation of Hydrogen and Kerosene Combustion in Supersonic Air Streams

    NASA Technical Reports Server (NTRS)

    Taha, A. A.; Tiwari, S. N.; Mohieldin, T. O.

    1999-01-01

    The effect of mixing schemes on the combustion of both gaseous hydrogen and liquid kerosene is investigated. Injecting pilot gaseous hydrogen parallel to the supersonic incoming air tends to maintain the stabilization of the main liquid kerosene, which is normally injected. Also the maximum kerosene equivalence ratio that can maintain stable flame can be increased by increasing the pilot energy level. The wedge flame holding contributes to an increased kerosene combustion efficiency by the generation of shock-jet interaction.

  20. Tankless Water Heater

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Kennedy Space Center specialists aided Space, Energy, Time Saving (SETS) Systems, Inc. in working out the problems they encountered with their new electronic "tankless" water heater. The flow switch design suffered intermittent problems. Hiring several testing and engineering firms produced only graphs, printouts, and a large expense, but no solutions. Then through the Kennedy Space Center/State of Florida Technology Outreach Program, SETS was referred to Michael Brooks, a 21-year space program veteran and flowmeter expert. Run throughout Florida to provide technical service to businesses at no cost, the program applies scientific and engineering expertise originally developed for space applications to the Florida business community. Brooks discovered several key problems, resulting in a new design that turned out to be simpler, yielding a 63 percent reduction in labor and material costs over the old design.

  1. Packaged die heater

    DOEpatents

    Spielberger, Richard; Ohme, Bruce Walker; Jensen, Ronald J.

    2011-06-21

    A heater for heating packaged die for burn-in and heat testing is described. The heater may be a ceramic-type heater with a metal filament. The heater may be incorporated into the integrated circuit package as an additional ceramic layer of the package, or may be an external heater placed in contact with the package to heat the die. Many different types of integrated circuit packages may be accommodated. The method provides increased energy efficiency for heating the die while reducing temperature stresses on testing equipment. The method allows the use of multiple heaters to heat die to different temperatures. Faulty die may be heated to weaken die attach material to facilitate removal of the die. The heater filament or a separate temperature thermistor located in the package may be used to accurately measure die temperature.

  2. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; back-up tax. 48.4082-4..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  3. Spacecraft fire-safety experiments for space station: Technology development mission

    NASA Technical Reports Server (NTRS)

    Youngblood, Wallace W.

    1988-01-01

    Three concept designs for low-gravity, fire-safety related experiments are presented, as selected for the purpose of addressing key issues of enhancing safety and yet encouraging access to long-duration, manned spacecraft such as the NASA space station. The selected low-gravity experiments are the following: (1) an investigation of the flame-spread rate and combustion-product evolution of the burning of typical thicknesses of spacecraft materials in very low-speed flows; (2) an evaluation of the interaction of fires and candidate extinguishers in various fire scenarios; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion. Each experiment is expected to provide fundamental combustion-science data, as well as the fire-safety applications, and each requires the unique long-duration, low-gravity environment of the space station. Two generic test facilities, i.e., the Combustion Tunnel Facility and the Combustion Facility, are proposed for space station accommodation to support the selected experiments. In addition, three near-term, fire-safety related experiments are described along with other related precursor activities.

  4. Fuel oil and kerosene sales 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-11-01

    This publication contains the 1991 survey results of the ``Annual Fuel Oil and Kerosene Sales Report`` (Form EIA-821). This is the third year that the survey data have appeared in a separate publication. Prior to the 1989 report, the statistics appeared in the Petroleum Marketing Annual (PMA) for reference year 1988 and the Petroleum Marketing Monthly (PMM) for reference years 1984 through 1987, The 1991 edition marks the eighth annual presentation, of the results of the ongoing ``Annual Fuel Oil and Kerosene Sales Report`` survey.

  5. 75 FR 58347 - Information Collection; Overcoming Barriers to Wildland Fire Defensible Space Behaviors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-24

    ... Information Collection; Overcoming Barriers to Wildland Fire Defensible Space Behaviors AGENCY: Forest Service... new information collection, Overcoming Barriers to Wildland Fire Defensible Space Behaviors. DATES... time, Monday through Friday. SUPPLEMENTARY INFORMATION: Title: Overcoming Barriers to Wildland Fire...

  6. Evaluation of Liquid Fuel Field Space Heaters: Standard Military, Developmental and Foreign

    DTIC Science & Technology

    1978-10-01

    least 15 kg/kg, (2) to react as much fuel as possible by the flameless combustion reaction, and (3) to maintain gas temperatures not higher than 1000...as there is enough oxygen there to support combustion . As the fuel flow increases, the flames move up until at maximum flow only flameless ...HEATING FIELD HEATING COMBUSTION COMBUSTION (LIQUID FUELS) HEATERS TENT HEATERS LIQUID FUELS FUELS LIQUIDS OXYGEN tS»TRACT rCoaltnu* an rmrormm

  7. Fuel oil and kerosene sales 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-27

    This publication contains the 1994 survey results of the ``Annual Fuel Oil and Kerosene Sales Report`` (Form EIA-821). This is the sixth year that the survey data have appeared in a separate publication. Prior to the 1989 report, the statistics appeared in the Petroleum Marketing Annual (PMA)for reference year 1988 and the Petroleum Marketing Monthly (PMM) for reference years 1984 through 1987. The 1994 edition marks the 11th annual presentation of the results of the ongoing ``Annual Fuel Oil and Kerosene Sales Report`` survey. Distillate and residual fuel oil sales continued to move in opposite directions during 1994. Distillate salesmore » rose for the third year in a row, due to a growing economy. Residual fuel oil sales, on the other hand, declined for the sixth year in a row, due to competitive natural gas prices, and a warmer heating season than in 1993. Distillate fuel oil sales increased 4.4 percent while residual fuel oil sales declined 1.6 percent. Kerosene sales decreased 1.4 percent in 1994.« less

  8. Water augmented indirectly-fired gas turbine systems and method

    DOEpatents

    Bechtel, Thomas F.; Parsons, Jr., Edward J.

    1992-01-01

    An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a higher driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1,000.degree. C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

  9. Kerosene poisoning in children

    PubMed Central

    Nouri, L.; Al-Rahim, K.

    1970-01-01

    The epidemiological and clinical aspects of 100 cases of kerosene poisoning have been studied. The use of gastric lavage is discussed, and it is considered that this measure is probably valuable in treatment. The importance of preventive measures is stressed. PMID:5416507

  10. 26 CFR 48.6427-11 - Kerosene; claims by registered ultimate vendors (blending).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-11 Kerosene... certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments allowed...

  11. 26 CFR 48.6427-11 - Kerosene; claims by registered ultimate vendors (blending).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-11 Kerosene... certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments allowed...

  12. 26 CFR 48.6427-11 - Kerosene; claims by registered ultimate vendors (blending).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-11 Kerosene... certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments allowed...

  13. 26 CFR 48.6427-11 - Kerosene; claims by registered ultimate vendors (blending).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-11 Kerosene... certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments allowed...

  14. An unusual case of suicide attempt using intravenous injection of kerosene.

    PubMed

    Jayaprasad, Sushmitha; Metikurke, Vijayashankar

    2013-01-01

    Kerosene is refined oil belonging to the hydrocarbon group of compounds, available for domestic use in developing countries. Poisoning is due to inhalation, ingestion. Kerosene. We report a rare case of attempted suicide by means of intravenous injection of kerosene. It has a devastating effect and it is important to initiate active and immediate surgical intervention. Psychotherapy should also be an integral part of the management.

  15. Four Bed Molecular Sieve - Exploration (4BMS-X) Virtual Heater Design and Optimization

    NASA Technical Reports Server (NTRS)

    Schunk, R. Gregory; Peters, Warren T.; Thomas, John T., Jr.

    2017-01-01

    A 4BMS-X (Four Bed Molecular Sieve - Exploration) design and heater optimization study for CO2 sorbent beds in proposed exploration system architectures is presented. The primary objectives of the study are to reduce heater power and thermal gradients within the CO2 sorbent beds while minimizing channeling effects. Some of the notable changes from the ISS (International Space Station) CDRA (Carbon Dioxide Removal Assembly) to the proposed exploration system architecture include cylindrical beds, alternate sorbents and an improved heater core. Results from both 2D and 3D sorbent bed thermal models with integrated heaters are presented. The 2D sorbent bed models are used to optimize heater power and fin geometry while the 3D models address end effects in the beds for more realistic thermal gradient and heater power predictions.

  16. West Valley demonstration project: Implementation of the kerosene mitigation plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blickwedehl, R.R.; Goodman, J.; Valenti, P.J.

    1987-05-01

    An aggressive program was implemented to mitigate the migration of radioactive kerosene believed to have originated from the West Valley NRC-Licensed Disposal Area (NDA) disposal trenches designated as SH-10 and SH-11 (Special Holes 10 and 11). This report provides a historical background of the events leading to the migration problem, the results of a detailed investigation to determine the location and source of the kerosene migration, the remediation plan to mitigate the migration, and the actions taken to successfully stabilize the kerosene. 7 refs., 19 figs., 1 tab.

  17. Environmental monitoring of adulterated gasoline with kerosene and their assessment at exhaust level.

    PubMed

    Sinha, Sukesh Narayan; Shivgotra, V K

    2012-07-01

    Fuel adulteration increases the emission of total hydrocarbons, carbon monoxide, nitrogen oxides and respirable particulate matter, and thus adds to air pollution. The study examined the effects of mixing of different percentage of kerosene with petrol on the motorized rickshaw exhausts in terms of volatile organic compounds (benzene, toluene, xylene and ethyl benzene) and total suspended particulate matter (SPM). The personal sampler was used for sampling, and gas chromatography-mass spectrometry for quantification of compounds. Concentration of volatile organic compounds significantly decreased (p < 0.001) along with the increase in fraction of kerosene in petrol. The level of benzene in exhausts while, using petrol (100%) was significantly higher (p < 0.001) than that of three combinations used in this study (75% petrol + 25% kerosene, 50% petrol + 50% kerosene and 25% petrol + 75% kerosene). Similar trend was observed for toluene, xylene and ethyl benzene also. The mean concentration of benzene, toluene, xylene and ethyl benzene were 31.34,160.93, 10.07 and 5.58 microg m(-3) in pure petrol, while 12.30, 51.41,4.89 and 3.16 microg m(-3) for fuel combination 75% petrol + 25% kerosene. The observed levels of benzene, toluene, xylene and ethyl benzene were 9.12, 41.04, 4.33 and 2.91 microg m(-3) for fuel mixture having 50% petrol with 50% kerosene and levels were 8.36, 20.05, 3.82 and 2.95 microg m(-3) were for 25% petrol with 75% kerosene fuel combination. The levels of suspended particulate matter (SPM) increased along with the increase in fraction of kerosene in petrol. The data generated is useful to understand the common volatile organic compounds trend with the increasing fraction of kerosene in petrol.

  18. The effect of hard water scale buildup and water treatment on residential water heater performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talbert, S.G.; Stickford, G.H.; Newman, D.C.

    Conventional gas and electric storage-type residential water heaters were operated at four different U.S. cities under accelerated test conditions to measure the effect of scale buildup on efficiency and to assess the benefits and limitations of common water treatment methods. The four selected test sites had hard water supplied with expected scale-forming tendencies and were located in Columbus, OH; Lisle, IL; Roswell, NM; and Marshall, MN. The main conclusions are as follows. After 60 lbs (27 kg) of scale buildup at two of the test sites (representing an estimated 20 years of equivalent scale buildup), the efficiency of the gasmore » water heaters gradually declined about 5%, while that of the electric water heaters remained constant. However, the buildup of scale in the electric heaters caused the electric heating element to fail periodically, and in the gas-fired heaters, it caused the tank metal temperatures near the burner to operate hotter. Treated water (either softened, softened plus polyphosphate, or hard plus polyphosphate) effectively reduced scale buildup and tended to reduce the corrosion rates of the metal test coupons in hot water.« less

  19. State-space decoding of primary afferent neuron firing rates

    NASA Astrophysics Data System (ADS)

    Wagenaar, J. B.; Ventura, V.; Weber, D. J.

    2011-02-01

    Kinematic state feedback is important for neuroprostheses to generate stable and adaptive movements of an extremity. State information, represented in the firing rates of populations of primary afferent (PA) neurons, can be recorded at the level of the dorsal root ganglia (DRG). Previous work in cats showed the feasibility of using DRG recordings to predict the kinematic state of the hind limb using reverse regression. Although accurate decoding results were attained, reverse regression does not make efficient use of the information embedded in the firing rates of the neural population. In this paper, we present decoding results based on state-space modeling, and show that it is a more principled and more efficient method for decoding the firing rates in an ensemble of PA neurons. In particular, we show that we can extract confounded information from neurons that respond to multiple kinematic parameters, and that including velocity components in the firing rate models significantly increases the accuracy of the decoded trajectory. We show that, on average, state-space decoding is twice as efficient as reverse regression for decoding joint and endpoint kinematics.

  20. Kerosene lighting contributes to household air pollution in rural Uganda.

    PubMed

    Muyanja, D; Allen, J G; Vallarino, J; Valeri, L; Kakuhikire, B; Bangsberg, D R; Christiani, D C; Tsai, A C; Lai, P S

    2017-09-01

    The literature on the contribution of kerosene lighting to indoor air particulate concentrations is sparse. In rural Uganda, kitchens are almost universally located outside the main home, and kerosene is often used for lighting. In this study, we obtained longitudinal measures of particulate matter 2.5 microns or smaller in size (PM 2.5 ) from living rooms and kitchens of 88 households in rural Uganda. Linear mixed-effects models with a random intercept for household were used to test the hypotheses that primary reported lighting source and kitchen location (indoor vs outdoor) are associated with PM 2.5 levels. During initial testing, households reported using the following sources of lighting: open-wick kerosene (19.3%), hurricane kerosene (45.5%), battery-powered (33.0%), and solar (1.1%) lamps. During follow-up testing, these proportions changed to 29.5%, 35.2%, 18.2%, and 9.1%, respectively. Average ambient, living room, and kitchen PM 2.5 levels were 20.2, 35.2, and 270.0 μg/m 3 . Living rooms using open-wick kerosene lamps had the highest PM 2.5 levels (55.3 μg/m 3 ) compared to those using solar lighting (19.4 μg/m 3 ; open wick vs solar, P=.01); 27.6% of homes using open-wick kerosene lamps met World Health Organization indoor air quality standards compared to 75.0% in homes using solar lighting. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Reliability-Based Life Assessment of Stirling Convertor Heater Head

    NASA Technical Reports Server (NTRS)

    Shah, Ashwin R.; Halford, Gary R.; Korovaichuk, Igor

    2004-01-01

    Onboard radioisotope power systems being developed and planned for NASA's deep-space missions require reliable design lifetimes of up to 14 yr. The structurally critical heater head of the high-efficiency Stirling power convertor has undergone extensive computational analysis of operating temperatures, stresses, and creep resistance of the thin-walled Inconel 718 bill of material. A preliminary assessment of the effect of uncertainties in the material behavior was also performed. Creep failure resistance of the thin-walled heater head could show variation due to small deviations in the manufactured thickness and in uncertainties in operating temperature and pressure. Durability prediction and reliability of the heater head are affected by these deviations from nominal design conditions. Therefore, it is important to include the effects of these uncertainties in predicting the probability of survival of the heater head under mission loads. Furthermore, it may be possible for the heater head to experience rare incidences of small temperature excursions of short duration. These rare incidences would affect the creep strain rate and, therefore, the life. This paper addresses the effects of such rare incidences on the reliability. In addition, the sensitivities of variables affecting the reliability are quantified, and guidelines developed to improve the reliability are outlined. Heater head reliability is being quantified with data from NASA Glenn Research Center's accelerated benchmark testing program.

  2. 26 CFR 48.6427-10 - Kerosene; claims by registered ultimate vendors (blocked pumps).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-10 Kerosene... which certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments...

  3. 26 CFR 48.6427-10 - Kerosene; claims by registered ultimate vendors (blocked pumps).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-10 Kerosene... which certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments...

  4. 26 CFR 48.6427-10 - Kerosene; claims by registered ultimate vendors (blocked pumps).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-10 Kerosene... which certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments...

  5. 26 CFR 48.6427-10 - Kerosene; claims by registered ultimate vendors (blocked pumps).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Kerosene; claims by registered ultimate vendors... Administrative Provisions of Special Application to Retailers and Manufacturers Taxes § 48.6427-10 Kerosene... which certain registered ultimate vendors of taxed kerosene may claim the income tax credits or payments...

  6. Encystment of Azotobacter nigricans grown diazotrophically on kerosene as sole carbon source.

    PubMed

    García-Esquivel, Gabriela; Calva-Calva, Graciano; Ferrera-Cerrato, Ronald; Fernández-Linares, Luis Carlos; Vázquez, Refugio Rodríguez; Esparza-García, Fernando José

    2009-03-01

    Encystment of Azotobacter nigricans was induced by its diazotrophic cultivation on kerosene. Its growth and nitrogenase activity were affected by kerosene in comparison to cultures grown on sucrose. Electron microscopy of vegetative cells showed that when nitrogenase activity was higher and the poly-beta-hydroxybutyrate granules were not present to a significant extent, peripheral bodies were abundant. After 8 days of culture on kerosene, the presence of cysts with intracellular bunches of poly-beta-hydroxybutyrate granules was observed. Germination of cysts bears germinating multicelled yet unbroken capsule cysts with up to three cells inside. This is the first report of encystment induction of Azotobacter species grown on kerosene.

  7. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  8. 26 CFR 48.6427-8 - Diesel fuel and kerosene; claims by ultimate purchasers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; claims by ultimate... kerosene; claims by ultimate purchasers. (a) Overview. This section provides rules under which ultimate purchasers of taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section...

  9. 26 CFR 48.6427-8 - Diesel fuel and kerosene; claims by ultimate purchasers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; claims by ultimate... kerosene; claims by ultimate purchasers. (a) Overview. This section provides rules under which ultimate purchasers of taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section...

  10. 26 CFR 48.6427-8 - Diesel fuel and kerosene; claims by ultimate purchasers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; claims by ultimate... kerosene; claims by ultimate purchasers. (a) Overview. This section provides rules under which ultimate purchasers of taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section...

  11. 26 CFR 48.6427-8 - Diesel fuel and kerosene; claims by ultimate purchasers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; claims by ultimate... kerosene; claims by ultimate purchasers. (a) Overview. This section provides rules under which ultimate purchasers of taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section...

  12. An intervention to reduce kerosene-related burns and poisonings in low-income South African communities.

    PubMed

    Schwebel, David C; Swart, Dehran; Simpson, Jennifer; Hobe, Phumla; Hui, Siu-Kuen Azor

    2009-07-01

    Unintentional injury rates in low- and middle-income countries are up to 50 times higher than high-income nations. In South Africa, kerosene (paraffin) is a leading cause of poisoning and burns, particularly in low-income communities where it serves as a primary fuel for light, cooking, and heating. This study tested a community-based intervention to reduce kerosene-related injury risk. The intervention used a train-the-trainers model, whereby expert trainers train local paraprofessionals, who in turn deliver educational materials to community residents. The intervention was theory-driven, pragmatically motivated, and culturally sensitive. Prospective quasi-experimental intervention design with nonequivalent case versus control groups. Three primary outcome measures were considered: self-reported knowledge of kerosene safety, observed practice of safe kerosene use, and self-reported recognition of risk for kerosene-related injury. ANOVA models suggest a large and significant increase in self-reported kerosene-related knowledge in the intervention community compared to the control community. There were smaller, but statistically significant changes, in kerosene-related safety practices and recognition of kerosene injury risk in the intervention community compared to the control community. The intervention was successful. A train-the-trainers model might be an effective educational tool to reduce kerosene-related injury risk in low-income communities within low- and middle-income countries.

  13. Laser aircraft. [using kerosene

    NASA Technical Reports Server (NTRS)

    Hertzberg, A.; Sun, K.; Jones, W. S.

    1979-01-01

    The concept of a laser-powered aircraft is discussed. Laser flight would be completely compatible with existing airports and air-traffic control, with the airplane using kerosene only power, up to a cruising altitude of 9 km where the laser satellite would lock on and beam laser energy to it. Two major components make up the laser turbofan, a heat exchanger for converting laser radiation into thermal energy, and conventional turbomachinery. The laser power satellite would put out 42 Mw using a solar-powered thermal engine to generate electrical power for the closed-cycle supersonic electric discharge CO laser, whose radiators, heat exchangers, supersonic diffuser, and ducting will amount to 85% of the total subsystem mass. Relay satellites will be used to intercept the beam from the laser satellite, correct outgoing beam aberrations, and direct the beam to the next target. A 300-airplane fleet with transcontinental range is projected to save enough kerosene to equal the energy content of the entire system, including power and relay satellites, in one year.

  14. Superheating of kerosene-surfactant-water interface formed in capillary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kitamura, Y.; Huang, Q.; Takahashi, T.

    1993-03-01

    To provide fundamental information about the microexplosion of emulsified fuels, the effect of surfactants on the superheating of a kerosene-water interface was experimentally investigated. Surfactants such as Span 80, NPE[sub 2], NPE[sub 5], and NPE[sub 7.5] were used. The three-layer sample was prepared in a capillary; the bottom layer was kerosene, the middle layer was water, and the upper layer was kerosene. The surfactants were dissolved in the upper kerosene layer. The 30-40 samples were used to determine the superheating temperature distribution. The superheating temperature decreases with increasing concentration of surfactant and approaches a constant distribution over a critical concentration.more » The superheating temperature also depends on the hydrophilic group of NPE[sub x]. To explain such an effect, the authors assumed that the surfactant was absorbed on the interface and accelerated the nucleation rate. The authors suggest a modified nucleation rate which includes the surface coverage by a surfactant. The model predicts that the presence of surfactants reduces the superheating temperature and makes the distribution broader. The prediction from this model is in good agreement with the experimental data.« less

  15. Simulation of Rocket-Grade Kerosene Flowing in an Electrically Heated Experimental Apparatus

    DTIC Science & Technology

    2015-07-01

    Technical Paper 3. DATES COVERED (From - To) July 2015-July 2015 4. TITLE AND SUBTITLE Simulation of Rocket Kerosene Flowing in an Electrically Heated...rocket-grade kerosene (RP-2) flowing in an electrically heated tube is simulated. The model and boundary conditions are selected so as to simulate an...and Astronautics 1 Simulation of Rocket-Grade Kerosene Flowing in an Electrically Heated Experimental Apparatus Ananda Himansu1 and Matthew C

  16. Fire safety of ground-based space facilities on the spaceport ;Vostochny;

    NASA Astrophysics Data System (ADS)

    Artamonov, Vladimir S.; Gordienko, Denis M.; Melikhov, Anatoly S.

    2017-06-01

    The facilities of the spaceport ;Vostochny; and the innovative technologies for fire safety to be implemented are considered. The planned approaches and prospects for fire safety ensuring at the facilities of the spaceport ;Vostochny; are presented herein, based on the study of emergency situations having resulted in fire accidents and explosion cases at the facilities supporting space vehicles operation.

  17. 26 CFR 48.4082-1 - Diesel fuel and kerosene; exemption for dyed fuel.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; exemption for dyed..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1 Diesel fuel and kerosene; exemption for dyed... fuel or kerosene if— (1) The person otherwise liable for tax is a taxable fuel registrant; (2) In the...

  18. 26 CFR 48.4082-1 - Diesel fuel and kerosene; exemption for dyed fuel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; exemption for dyed..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1 Diesel fuel and kerosene; exemption for dyed... fuel or kerosene if— (1) The person otherwise liable for tax is a taxable fuel registrant; (2) In the...

  19. 26 CFR 48.4082-1 - Diesel fuel and kerosene; exemption for dyed fuel.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; exemption for dyed..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1 Diesel fuel and kerosene; exemption for dyed... fuel or kerosene if— (1) The person otherwise liable for tax is a taxable fuel registrant; (2) In the...

  20. 26 CFR 48.4082-1 - Diesel fuel and kerosene; exemption for dyed fuel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; exemption for dyed..., Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1 Diesel fuel and kerosene; exemption for dyed... fuel or kerosene if— (1) The person otherwise liable for tax is a taxable fuel registrant; (2) In the...

  1. Molded polymer solar water heater

    DOEpatents

    Bourne, Richard C.; Lee, Brian E.

    2004-11-09

    A solar water heater has a rotationally-molded water box and a glazing subassembly disposed over the water box that enhances solar gain and provides an insulating air space between the outside environment and the water box. When used with a pressurized water system, an internal heat exchanger is integrally molded within the water box. Mounting and connection hardware is included to provide a rapid and secure method of installation.

  2. Study of aircraft crashworthiness for fire protection

    NASA Technical Reports Server (NTRS)

    Cominsky, A.

    1981-01-01

    Impact-survivable postcrash fire accidents were surveyed. The data base developed includes foreign and domestic accidents involving airlines and jet aircraft. The emphasis was placed on domestic accidents, airlines, and jet aircraft due principally to availability of information. Only transport category aircraft in commercial service designed under FAR Part 25 were considered. A matrix was prepared to show the relationships between the accident characteristics and the fire fatalities. Typical postcrash fire scenaries were identified. Safety concepts were developed for three engineering categories: cabin interiors - cabin subsystems; power plant - engines and fuel systems; and structural mechanics - primary and secondary structures. The parameters identified for concept evaluation are cost, effectiveness, and societal concerns. Three concepts were selected for design definition and cost and effectiveness analysis: improved fire-resistant seat materials; anti-misting kerosene; and additional cabin emergency exits.

  3. Flame burns involving kerosene pressure stoves in India.

    PubMed

    Sawhney, C P

    1989-12-01

    The author has analysed 339 patients with extensive burns admitted to a teaching hospital and found them to be most common in poor socioeconomic groups with low incomes, poor housing and illiteracy. Thermal injuries afflicted 89 per cent of the patients and were generally accidental and occurred in homes with floor-level cooking: chemical and electrical burns (the remaining 11 per cent) were uncommon. Kerosene pressure stove accidents were a common cause of thermal burns and occurred in 65 per cent of the patients. These were reported in both sexes but were 3.5 times more common in females. Mishandling of kerosene pressure stoves was the commonest cause and occurred in 65.7 per cent of the patients and the next most common cause was wearing loose garments. Kerosene pressure stove accidents occurred commonly in the age group 16-35 years and were rare in other age groups. These burns were relatively more extensive, deep and carried a high mortality.

  4. Fuel oil and kerosene sales, 1994 (for microcomputers). Data file

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-10-01

    Annual petroleum marketing data are available on this diskette which contains statistics from the Fuel Oil and Kerosene Sales 1994 report. Included are annual sales data on petroleum volumes of kerosene, distillate fuel oil, and residual fuel oil by state. Annual historic data at the national level are provided in summary tables.

  5. Progress in Fire Detection and Suppression Technology for Future Space Missions

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Urban, David L.

    2000-01-01

    Fire intervention technology (detection and suppression) is a critical part of the strategy of spacecraft fire safety. This paper reviews the status, trends, and issues in fire intervention, particularly the technology applied to the protection of the International Space Station and future missions beyond Earth orbit. An important contribution to improvements in spacecraft fire safety is the understanding of the behavior of fires in the non-convective (microgravity) environment of Earth-orbiting and planetary-transit spacecraft. A key finding is the strong influence of ventilation flow on flame characteristics, flammability limits and flame suppression in microgravity. Knowledge of these flow effects will aid the development of effective processes for fire response and technology for fire suppression.

  6. Home Fires

    MedlinePlus

    ... to the touch and lights that flicker. Portable Space Heaters Keep combustible objects at least three feet ... Radiological Dispersion Device Severe Weather Snowstorms & Extreme Cold Space Weather Thunderstorms & Lightning Tornadoes Tsunamis Volcanoes Wildfires Ready. ...

  7. 40 CFR 63.7491 - Are any boilers or process heaters not subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .../infectious waste incinerator covered by 40 CFR part 60, subpart Ce or subpart Ec. (c) An electric utility... furnace stoves as described in the EPA document, entitled “National Emission Standards for Hazardous Air... boilers as defined in this subpart. (o) Blast furnace gas fuel-fired boilers and process heaters as...

  8. Subsurface heaters with low sulfidation rates

    DOEpatents

    John, Randy Carl; Vinegar, Harold J

    2013-12-10

    A system for heating a hydrocarbon containing formation includes a heater having an elongated ferromagnetic metal heater section. The heater is located in an opening in a formation. The heater section is configured to heat the hydrocarbon containing formation. The exposed ferromagnetic metal has a sulfidation rate that goes down with increasing temperature of the heater, when the heater is in a selected temperature range.

  9. Fuel oil and kerosene sales 1991. [USA, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-11-01

    This publication contains the 1991 survey results of the Annual Fuel Oil and Kerosene Sales Report'' (Form EIA-821). This is the third year that the survey data have appeared in a separate publication. Prior to the 1989 report, the statistics appeared in the Petroleum Marketing Annual (PMA) for reference year 1988 and the Petroleum Marketing Monthly (PMM) for reference years 1984 through 1987, The 1991 edition marks the eighth annual presentation, of the results of the ongoing Annual Fuel Oil and Kerosene Sales Report'' survey.

  10. Investigation of flameholding mechanisms in a kerosene-fueled scramjet combustor

    NASA Astrophysics Data System (ADS)

    Wang, Yu-hang; Song, Wen-yan; Shi, De-yong

    2017-11-01

    Laser-induced fluorescence and high-speed photography were employed to investigate the kerosene flame stabilization mechanism in a cavity-based scramjet combustor with an inlet condition corresponds to flight Mach number of 4. Pilot hydrogen was used to ignite the kerosene fuel. The PLIF results of kerosene distribution in the reacting cases showed that the mixing process was dramatically enhanced compared to the non-reacting cases. Sharp OH gradients were observed in the shear layer and the aft region of cavity, which indicated that the flame was located at these positions. A portion of hot products participated in the recirculation of the cavity and preheated the kerosene-air mixture in the leading edge. The heated mixture was ignited in the mid-cavity and the reaction zone spread into the mainstream flow. Due to the competition between the local flame speed and the local flow speed, the high-speed images showed that the spreading location was in fluctuation. This movement was observed to cause a low-frequency wall pressure fluctuation.

  11. Grouped exposed metal heaters

    DOEpatents

    Vinegar, Harold J.; Coit, William George; Griffin, Peter Terry; Hamilton, Paul Taylor; Hsu, Chia-Fu; Mason, Stanley Leroy; Samuel, Allan James; Watkins, Ronnie Wade

    2010-11-09

    A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

  12. Grouped exposed metal heaters

    DOEpatents

    Vinegar, Harold J [Bellaire, TX; Coit, William George [Bellaire, TX; Griffin, Peter Terry [Brixham, GB; Hamilton, Paul Taylor [Houston, TX; Hsu, Chia-Fu [Granada Hills, CA; Mason, Stanley Leroy [Allen, TX; Samuel, Allan James [Kular Lumpar, ML; Watkins, Ronnie Wade [Cypress, TX

    2012-07-31

    A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

  13. [Strengthening Effects of Sodium Salts on Washing Kerosene Contaminated Soil with Surfactants].

    PubMed

    Huang, Zhao-lu; Chen, Quan-yuan; Zhou, Juan; Xie, Mo-han

    2015-05-01

    The impact of sodium salt on kerosene contaminated soil washing with surfactants was investigated. The results indicated that sodium silicate greatly enhanced the washing efficiency of SDS. Sodium tartrate can largely enhance the washing efficiency of SDBS and Brij35. Sodium salts can enhance the washing efficiency on kerosene contaminated with TX-100. No significant differences were observed between different sodium salts. Sodium salt of humic acid and sodium silicate had similar enhancement on kerosene contaminated soil washing with saponin. Sodium humate can be a better choice since its application can also improve soil quality. The enhancement of sodium silicate on kerosene contaminated soil washing with Tw-80 increased with the increase of Tw-80 dosage. However, the impact of sodium chloride and sodium tartrate was opposite to sodium silicate. Sodium salts can reduce surface tension and critical micelle concentration of ionic surfactants to enhance the washing. Sodium salts can also reduce re-adsorption of oil to soil with nonionic surfactants to enhance the washing. Kerosene contamination can increase the contact angle of soil, which indicated the increase of hydrophilicity of soil. Washing with surfactants can reduce the hydrophilicitiy of soil according to contact angle measurement, which indicated that kerosene contaminated soil remediation with surfactant can also benefit nutrient and water transportation in the contaminated soil.

  14. Fire safety practices in the Shuttle and the Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.

  15. The great Chinese fire of 1987 - A view from space

    NASA Technical Reports Server (NTRS)

    Cahoon, Donald R., Jr.; Levine, Joel S.; Cofer, Wesley R., III; Miller, James E.; Minnis, Patrick; Tennille, Geoffrey M.; Yip, Tommy W.; Stocks, Brian J.; Heck, Patrick W.

    1991-01-01

    One of the largest forest fires ever recorded burned in the People's Republic of China (PRC) and the Soviet Union in May 1987. The fire covered over 1.0 million hectares in the PRC and almost 4 million hectares in the Soviet Union. The progress and areal extent of the fire were measured using satellite images analyzed in the imaging facilities at NASA-Langley and Forestry Canada. The analyses show the utility and value of satellite measurements to assess the areal extent and geographical distribution of fires, and have important implications for future measurements to be obtained from space platforms, such as the Earth Observing System.

  16. Commercial Absorption Heat Pump Water Heater: Beta Prototype Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geoghegan, Patrick; Ally, Moonis; Sharma, Vishaldeep

    2016-10-14

    The Beta version of the Commercial Absorption Heat Pump (CAHP) water heater was evaluated in the environmental chambers at Oak Ridge National Laboratory. Ambient air conditions ranged from 17 to 75 oF and inlet water temperatures ranged from 100 to 120oF in order to capture trends in performance. The unit was operated under full fire (100%) and partial fire (55%). The unit was found to perform at 90% of the project goal at the design conditions of 47oF ambient and 100oF water temperatures. The trends across the full range of environmental conditions were as expected for ambient air temperatures abovemore » 32oF. Below this temperature and for the full fire condition, frost accumulated on the evaporator coil. In future work a defrost strategy will be enabled, the unit will be thoroughly cleaned of an oil contamination and the rectifier will be reconfigured in order to meet the design goals and have a field test unit ready in early 2017.« less

  17. Kerosene/Water/2,4-Dinitrophenol.

    ERIC Educational Resources Information Center

    Whyman, Derek

    1986-01-01

    Background information/theory, procedures used, and typical results obtained are discussed for a system in which kerosene, water, and 2,4-dinitrophenol (DNP) are used to demonstrate the principles of liquid-liquid extraction in a Graesser rotary contractor. The DNP is almost equal between the two disimilar solvents. (JN)

  18. A Mobile Heat Applicator for Simulating Prescribed Fire Intensities

    Treesearch

    Stephen S. Sackett; Darold E. Ward

    1972-01-01

    In testing the degree of tolerance or susceptibility of tree stems to heat from prescribed fires, it is desirable to apply controlled quantities of heat to the lower bole. This paper describes an infrared heater capable of simulating the intensities of prescribed fires and mobile enough for use in the field under natural conditions. Procedures for calibrating the unit...

  19. 26 CFR 48.4082-2 - Diesel fuel and kerosene; notice required for dyed fuel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; notice required for..., Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-2 Diesel fuel and kerosene; notice... “DYED KEROSENE, NONTAXABLE USE ONLY, PENALTY FOR TAXABLE USE” must be posted by a seller on any retail...

  20. 26 CFR 48.4082-2 - Diesel fuel and kerosene; notice required for dyed fuel.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; notice required for..., Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-2 Diesel fuel and kerosene; notice... “DYED KEROSENE, NONTAXABLE USE ONLY, PENALTY FOR TAXABLE USE” must be posted by a seller on any retail...

  1. 26 CFR 48.4082-2 - Diesel fuel and kerosene; notice required for dyed fuel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; notice required for..., Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-2 Diesel fuel and kerosene; notice... “DYED KEROSENE, NONTAXABLE USE ONLY, PENALTY FOR TAXABLE USE” must be posted by a seller on any retail...

  2. 26 CFR 48.4082-2 - Diesel fuel and kerosene; notice required for dyed fuel.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; notice required for..., Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-2 Diesel fuel and kerosene; notice... “DYED KEROSENE, NONTAXABLE USE ONLY, PENALTY FOR TAXABLE USE” must be posted by a seller on any retail...

  3. Flat plate solar air heater with latent heat storage

    NASA Astrophysics Data System (ADS)

    Touati, B.; Kerroumi, N.; Virgone, J.

    2017-02-01

    Our work contains two parts, first is an experimental study of the solar air heater with a simple flow and forced convection, we can use thatlaste oneit in many engineering's sectors as solardrying, space heating in particular. The second part is a numerical study with ansys fluent 15 of the storage of part of this solar thermal energy produced,using latent heat by using phase change materials (PCM). In the experimental parts, we realize and tested our solar air heater in URER.MS ADRAR, locate in southwest Algeria. Where we measured the solarradiation, ambient temperature, air flow, thetemperature of the absorber, glasses and the outlet temperature of the solar air heater from the Sunrise to the sunset. In the second part, we added a PCM at outlet part of the solar air heater. This PCM store a part of the energy produced in the day to be used in peak period at evening by using the latent heat where the PCMs present a grateful storagesystem.A numerical study of the fusion or also named the charging of the PCM using ANSYS Fluent 15, this code use the method of enthalpies to solve the fusion and solidification formulations. Furthermore, to improve the conjugate heat transfer between the heat transfer fluid (Air heated in solar plate air heater) and the PCM, we simulate the effect of adding fins to our geometry. Also, four user define are write in C code to describe the thermophysicalpropriety of the PCM, and the inlet temperature of our geometry which is the temperature at the outflow of the solar heater.

  4. Development of the International Space Station Fine Water Mist Portable Fire Extinguisher

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle; Young, GIna

    2013-01-01

    The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segments, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic fire extinguisher to mitigate this operational risk. The FWM PFE can extinguish a fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.

  5. Coaxial Electric Heaters

    NASA Technical Reports Server (NTRS)

    Strekalov, Dmitry; Matsko, Andrey; Savchenkov, Anatoliy; Maleki, Lute

    2008-01-01

    Coaxial electric heaters have been conceived for use in highly sensitive instruments in which there are requirements for compact heaters but stray magnetic fields associated with heater electric currents would adversely affect operation. Such instruments include atomic clocks and magnetometers that utilize heated atomic-sample cells, wherein stray magnetic fields at picotesla levels could introduce systematic errors into instrument readings. A coaxial electric heater is essentially an axisymmetric coaxial cable, the outer conductor of which is deliberately made highly electrically resistive so that it can serve as a heating element. As in the cases of other axisymmetric coaxial cables, the equal magnitude electric currents flowing in opposite directions along the inner and outer conductors give rise to zero net magnetic field outside the outer conductor. Hence, a coaxial electric heater can be placed near an atomic-sample cell or other sensitive device. A coaxial electric heater can be fabricated from an insulated copper wire, the copper core of which serves as the inner conductor. For example, in one approach, the insulated wire is dipped in a colloidal graphite emulsion, then the emulsion-coated wire is dried to form a thin, uniform, highly electrically resistive film that serves as the outer conductor. Then the film is coated with a protective layer of high-temperature epoxy except at the end to be electrically connected to the power supply. Next, the insulation is stripped from the wire at that end. Finally, electrical leads from the heater power supply are attached to the exposed portions of the wire and the resistive film. The resistance of the graphite film can be tailored via its thickness. Alternatively, the film can be made from an electrically conductive paint, other than a colloidal graphite emulsion, chosen to impart the desired resistance. Yet another alternative is to tailor the resistance of a graphite film by exploiting the fact that its resistance

  6. Immersible solar heater for fluids

    DOEpatents

    Kronberg, James W.

    1995-01-01

    An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

  7. Solar heating and domestic hot water system installed at Kansas City, Fire Station, Kansas City, Missouri. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1980-07-01

    This document is the final report of the solar energy heating and hot water system installed at the Kansas City Fire Station, Number 24, 2309 Hardesty Street, Kansas City, Missouri. The solar system was designed to provide 47 percent of the space heating, 8800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1428 cubic feet of 1/2 inch diameter pebbles weighing 71 1/2 tons, a DHW preheat tank, blowers, pumps, heatmore » exchangers, air ducting, controls and associated plumbing. Two 120-gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30-kilowatt electric unit heaters. There are six modes of system operation. This project is part of the Department of Energy PON-1 Solar Demonstration Program with DOE cost sharing $154,282 of the $174,372 solar system cost. The Final Design Review was held March 1977, the system became operational March 1979 and acceptance test was completed in September 1979.« less

  8. Hot gas engine heater head

    DOEpatents

    Berntell, John O.

    1983-01-01

    A heater head for a multi-cylinder double acting hot gas engine in which each cylinder is surrounded by an annular regenerator unit, and in which the tops of each cylinder and its surrounding regenerator are interconnected by a multiplicity of heater tubes. A manifold for the heater tubes has a centrally disposed duct connected to the top of the cylinder and surrounded by a wider duct connecting the other ends of the heater tubes with the regenerator unit.

  9. Household light makes global heat: high black carbon emissions from kerosene wick lamps.

    PubMed

    Lam, Nicholas L; Chen, Yanju; Weyant, Cheryl; Venkataraman, Chandra; Sadavarte, Pankaj; Johnson, Michael A; Smith, Kirk R; Brem, Benjamin T; Arineitwe, Joseph; Ellis, Justin E; Bond, Tami C

    2012-12-18

    Kerosene-fueled wick lamps used in millions of developing-country households are a significant but overlooked source of black carbon (BC) emissions. We present new laboratory and field measurements showing that 7-9% of kerosene consumed by widely used simple wick lamps is converted to carbonaceous particulate matter that is nearly pure BC. These high emission factors increase previous BC emission estimates from kerosene by 20-fold, to 270 Gg/year (90% uncertainty bounds: 110, 590 Gg/year). Aerosol climate forcing on atmosphere and snow from this source is estimated at 22 mW/m² (8, 48 mW/m²), or 7% of BC forcing by all other energy-related sources. Kerosene lamps have affordable alternatives that pose few clear adoption barriers and would provide immediate benefit to user welfare. The net effect on climate is definitively positive forcing as coemitted organic carbon is low. No other major BC source has such readily available alternatives, definitive climate forcing effects, and cobenefits. Replacement of kerosene-fueled wick lamps deserves strong consideration for programs that target short-lived climate forcers.

  10. Immersible solar heater for fluids

    DOEpatents

    Hazen, T.C.; Fliermans, C.B.

    1994-01-01

    An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

  11. Immersible solar heater for fluids

    DOEpatents

    Kronberg, J.W.

    1995-07-11

    An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

  12. Quantitative Risk Modeling of Fire on the International Space Station

    NASA Technical Reports Server (NTRS)

    Castillo, Theresa; Haught, Megan

    2014-01-01

    The International Space Station (ISS) Program has worked to prevent fire events and to mitigate their impacts should they occur. Hardware is designed to reduce sources of ignition, oxygen systems are designed to control leaking, flammable materials are prevented from flying to ISS whenever possible, the crew is trained in fire response, and fire response equipment improvements are sought out and funded. Fire prevention and mitigation are a top ISS Program priority - however, programmatic resources are limited; thus, risk trades are made to ensure an adequate level of safety is maintained onboard the ISS. In support of these risk trades, the ISS Probabilistic Risk Assessment (PRA) team has modeled the likelihood of fire occurring in the ISS pressurized cabin, a phenomenological event that has never before been probabilistically modeled in a microgravity environment. This paper will discuss the genesis of the ISS PRA fire model, its enhancement in collaboration with fire experts, and the results which have informed ISS programmatic decisions and will continue to be used throughout the life of the program.

  13. 26 CFR 48.4082-1T - Diesel fuel and kerosene; exemption for dyed fuel (temporary).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; exemption for dyed... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1T Diesel fuel and kerosene... this section, diesel fuel or kerosene satisfies the dyeing requirements of this paragraph (d) only if...

  14. 26 CFR 48.4082-1T - Diesel fuel and kerosene; exemption for dyed fuel (temporary).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; exemption for dyed... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1T Diesel fuel and kerosene... this section, diesel fuel or kerosene satisfies the dyeing requirements of this paragraph (d) only if...

  15. 26 CFR 48.4082-1T - Diesel fuel and kerosene; exemption for dyed fuel (temporary).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; exemption for dyed... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1T Diesel fuel and kerosene... this section, diesel fuel or kerosene satisfies the dyeing requirements of this paragraph (d) only if...

  16. 26 CFR 48.4082-1T - Diesel fuel and kerosene; exemption for dyed fuel (temporary).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; exemption for dyed... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-1T Diesel fuel and kerosene... this section, diesel fuel or kerosene satisfies the dyeing requirements of this paragraph (d) only if...

  17. Remote sensing of fire and deforestation in the tropics from the International Space Station

    NASA Astrophysics Data System (ADS)

    Hoffman, James W.; Riggan, Philip J.; Brass, James A.

    2000-01-01

    In August of 1999 over 30,000 fire counts were registered by the Advanced Very High Resolution Radiometer aboard NOAA satellites over central Brazil, and an extensive smoke pall produced a health hazard and hindered commercial aviation across large portions of the states of Mato Grosso and Mato Grosso do Sul. Clearly fire was an important part of the Brazilian environment, but limitations in satellite and airborne remote sensing prevented a clear picture of what was burning, how much biomass was consumed, where the most critical resources were threatened, or exactly what was the global environmental impact. Another important problem that must be addressed is the deforestation of the rain forest by unauthorized logging operations. To detect these illegal clear cutting activities, continuous, high resolution monitoring must be initiated. The low altitude Space Station offers an ideal platform from which to monitor the tropical regions for both fires and deforestation from an equatorial orbit. A new micro-bolometer-based thermal imager, the FireMapper, has been designed to provide a solution for these problems in fire and resource monitoring. In this paper we describe potential applications of the FireMapper aboard the International Space Station for demonstration of space-borne fire detection and measurement. .

  18. 46 CFR 182.320 - Water heaters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Water heaters. 182.320 Section 182.320 Shipping COAST...) MACHINERY INSTALLATION Auxiliary Machinery § 182.320 Water heaters. (a) A water heater must meet the...), except that an electric water heater is also acceptable if it: (1) Has a capacity of not more than 454...

  19. 46 CFR 182.320 - Water heaters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Water heaters. 182.320 Section 182.320 Shipping COAST...) MACHINERY INSTALLATION Auxiliary Machinery § 182.320 Water heaters. (a) A water heater must meet the...), except that an electric water heater is also acceptable if it: (1) Has a capacity of not more than 454...

  20. 46 CFR 182.320 - Water heaters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Water heaters. 182.320 Section 182.320 Shipping COAST...) MACHINERY INSTALLATION Auxiliary Machinery § 182.320 Water heaters. (a) A water heater must meet the...), except that an electric water heater is also acceptable if it: (1) Has a capacity of not more than 454...

  1. 46 CFR 182.320 - Water heaters.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Water heaters. 182.320 Section 182.320 Shipping COAST...) MACHINERY INSTALLATION Auxiliary Machinery § 182.320 Water heaters. (a) A water heater must meet the...), except that an electric water heater is also acceptable if it: (1) Has a capacity of not more than 454...

  2. 46 CFR 182.320 - Water heaters.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Water heaters. 182.320 Section 182.320 Shipping COAST...) MACHINERY INSTALLATION Auxiliary Machinery § 182.320 Water heaters. (a) A water heater must meet the...), except that an electric water heater is also acceptable if it: (1) Has a capacity of not more than 454...

  3. 53. THRUST SECTION HEATER AND GASEOUS NITROGEN PURGE CONTROLS ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    53. THRUST SECTION HEATER AND GASEOUS NITROGEN PURGE CONTROLS ON EAST SIDE OF LAUNCH DECK. LAUNCHER IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  4. 46 CFR 119.320 - Water heaters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Water heaters. 119.320 Section 119.320 Shipping COAST... Machinery § 119.320 Water heaters. (a) A water heater must meet the requirements of Parts 53 and 63 in... electric water heater is also acceptable if it: (1) Has a capacity of not more than 454 liters (120 gallons...

  5. 46 CFR 119.320 - Water heaters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water heaters. 119.320 Section 119.320 Shipping COAST... Machinery § 119.320 Water heaters. (a) A water heater must meet the requirements of Parts 53 and 63 in... electric water heater is also acceptable if it: (1) Has a capacity of not more than 454 liters (120 gallons...

  6. 46 CFR 119.320 - Water heaters.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Water heaters. 119.320 Section 119.320 Shipping COAST... Machinery § 119.320 Water heaters. (a) A water heater must meet the requirements of Parts 53 and 63 in... electric water heater is also acceptable if it: (1) Has a capacity of not more than 454 liters (120 gallons...

  7. 46 CFR 119.320 - Water heaters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Water heaters. 119.320 Section 119.320 Shipping COAST... Machinery § 119.320 Water heaters. (a) A water heater must meet the requirements of Parts 53 and 63 in... electric water heater is also acceptable if it: (1) Has a capacity of not more than 454 liters (120 gallons...

  8. 46 CFR 119.320 - Water heaters.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Water heaters. 119.320 Section 119.320 Shipping COAST... Machinery § 119.320 Water heaters. (a) A water heater must meet the requirements of Parts 53 and 63 in... electric water heater is also acceptable if it: (1) Has a capacity of not more than 454 liters (120 gallons...

  9. Delicious Low GL space foods by using Low GI materials -IH and Vacuum cooking -

    NASA Astrophysics Data System (ADS)

    Katayama, Naomi; Nagasaka, Sanako; Murasaki, Masahiro; Space Agriculture Task Force, J.

    Enough life-support systems are necessary to stay in space for a long term. The management of the meal for astronauts is in particular very important. When an astronaut gets sick in outer space, it means death. To astronauts, the delicious good balance space foods are essential for their work. This study was aimed at making balance space foods menu for the healthy space-life. The kitchen utensil has a limit in the space environment. And a method to warm is only heater without fire. Therefore purpose of this study, we make the space foods which make by using vacuum cooking device and the IH heater We made space foods menu to referred to Japanese nutrition standard in 2010. We made space foods menu which are using "brown rice, wheat, soy bean, sweet potato and green-vegetable" and " loach and insects which are silkworm pupa, snail, mud snail, turmait, fly, grasshopper, bee". We use ten health adults as subjects. Ten subjects performed the sensory test of the questionnaire method. There was the sensuality examination in the item of "taste, a fragrance, color, the quantity" and acquired a mark at ten points of perfect scores.. We could make the space foods which we devised with vacuum cooking and IH deliciously. As a result of sensuality examination, the eight points in ten points of perfect scores was appeared. This result showed, our space food menu is delicious. We can store these space foods with a refrigerator for 20 days by making vacuum cooking. This thing is at all important result so that a save is enabled when surplus food was done in future by performing vacuum cooking. We want to make delicious space foods menu with vacuum cooking and IH heater more in future.

  10. Household Light Makes Global Heat: High Black Carbon Emissions From Kerosene Wick Lamps

    PubMed Central

    Lam, Nicholas L.; Chen, Yanju; Weyant, Cheryl; Venkataraman, Chandra; Sadavarte, Pankaj; Johnson, Michael A.; Smith, Kirk R.; Brem, Benjamin T.; Arineitwe, Joseph; Ellis, Justin E.; Bond, Tami C.

    2012-01-01

    Kerosene-fueled wick lamps used in millions of developing-country households are a significant but overlooked source of black carbon (BC) emissions. We present new laboratory and field measurements showing that 7–9% of kerosene consumed by widely used simple wick lamps is converted to carbonaceous particulate matter that is nearly pure BC. These high emission factors increase previous BC emission estimates from kerosene by 20-fold, to 270 Gg/year (90% uncertainty bounds: 110, 590 Gg/year). Aerosol climate forcing on atmosphere and snow from this source is estimated at 22 mW/m2 (8, 48 mW/m2), or 7% of BC forcing by all other energy-related sources. Kerosene lamps have affordable alternatives that pose few clear adoption barriers and would provide immediate benefit to user welfare. The net effect on climate is definitively positive forcing as co-emitted organic carbon is low. No other major BC source has such readily available alternatives, definitive climate forcing effects, and co-benefits. Replacement of kerosene-fueled wick lamps deserves strong consideration for programs that target short-lived climate forcers. PMID:23163320

  11. Dermal absorption of kerosene components in rats and the influence of its amount and area of exposure.

    PubMed

    Tsujino, Yoshio; Hieda, Yoko; Kimura, Kojiro; Dekio, Satoshi

    2003-04-23

    The influences of amount and area of dermal exposure to kerosene upon the levels of kerosene components in biological samples were examined in vivo and in vitro. Thirty-two rats were randomly divided into four groups and exposed to kerosene through the abdominal skin for 2h. The amounts (soaked in cotton) and area of kerosene exposed were 1 ml/4 cm(2) in Group I, 4 ml/4 cm(2) in Group II, 4 ml/16 cm(2) in Group III and 16 ml/64 cm(2) in Group IV. Before, then 5, 10, 20, 30, 45, 60, 90 and 120 min after exposure, 0.5 ml of blood was collected. Solid tissue samples, including the exposed skin area, were harvested at 120 min. Kerosene components were analyzed by gas chromatography/mass spectrometry. Trimethylbenzens (TMBs) that are easily absorbed kerosene components, appeared at 5-20 min. The time course changes in TMB levels in blood were significantly different between Groups I and II or Groups I and III, and almost identical between Groups II and III. Similar trends were observed in tissue samples at 120 min. High concentrations of aliphatic hydrocarbons (AHCs) were detected in the exposed skin and the AHC levels were dependent on the amount of kerosene exposed per unit area. These results suggest that (1) dermal absorption of kerosene occurs soon after dermal exposure started, (2) absorption of TMBs is influenced by the total amount of kerosene rather than area of exposure, and (3) AHCs remaining in the skin at significant levels are influenced by the amount of kerosene per unit area exposed.

  12. Design and optimization of resistance wire electric heater for hypersonic wind tunnel

    NASA Astrophysics Data System (ADS)

    Rehman, Khurram; Malik, Afzaal M.; Khan, I. J.; Hassan, Jehangir

    2012-06-01

    The range of flow velocities of high speed wind tunnels varies from Mach 1.0 to hypersonic order. In order to achieve such high speed flows, a high expansion nozzle is employed in the converging-diverging section of wind tunnel nozzle. The air for flow is compressed and stored in pressure vessels at temperatures close to ambient conditions. The stored air is dried and has minimum amount of moisture level. However, when this air is expanded rapidly, its temperature drops significantly and liquefaction conditions can be encountered. Air at near room temperature will liquefy due to expansion cooling at a flow velocity of more than Mach 4.0 in a wind tunnel test section. Such liquefaction may not only be hazardous to the model under test and wind tunnel structure; it may also affect the test results. In order to avoid liquefaction of air, a pre-heater is employed in between the pressure vessel and the converging-diverging section of a wind tunnel. A number of techniques are being used for heating the flow in high speed wind tunnels. Some of these include the electric arc heating, pebble bed electric heating, pebble bed natural gas fired heater, hydrogen burner heater, and the laser heater mechanisms. The most common are the pebble bed storage type heaters, which are inefficient, contaminating and time consuming. A well designed electrically heating system can be efficient, clean and simple in operation, for accelerating the wind tunnel flow up to Mach 10. This paper presents CFD analysis of electric preheater for different configurations to optimize its design. This analysis has been done using ANSYS 12.1 FLUENT package while geometry and meshing was done in GAMBIT.

  13. Analysis of the performance and space conditioning impacts of dedicated heat pump water heaters

    NASA Astrophysics Data System (ADS)

    Morrison, L.; Swisher, J.

    The development and testing of the newly-marketed dedicated heat pump water heater (HPWH) are described. This system utilizes an air-to-water heat pump, costs about $1,000 installed, and obtains a coefficient of performance (COP) of about 2.0 in laboratory and field tests. To investigate HPWH performance and space conditioning impacts, a simulation was developed to mode the thermal performance of a residence with resistance baseboard heat, air conditioning, and either heat pump or resistance water heating. The building characteristics are adapted for three U.S. geographical areas (Madison, Wisconsin; Washington, D.C.; and Ft. Worth, Texas), and the system is simulated for a year with typical weather data. The thermal network includes both a house node and a basement node so that the water heating equipment can be simulated in an unconditioned basement in Northern cities and in a conditioned first-floor utility room in Southern cities.

  14. Persistence and biodegradation of kerosene in high-arctic intertidal sediment.

    PubMed

    Røberg, Stian; Stormo, Svein Kristian; Landfald, Bjarne

    2007-10-01

    A kerosene type hydrocarbon fraction (equivalent to 7 L m(-2)) was added to enclosures in the surface layer of high-arctic intertidal beach sediment. The experimental spill was repeated in two consecutive years in the period July-September. The rate and extent of hydrocarbon removal and the accompanying bacterial response were monitored for 79 days (2002) and 78 days (2003). The bulk of added kerosene, i.e. 94-98%, was lost from the upper 5 cm layer by putatively abiotic processes within 2 days and a residual fraction in the range 0.6-1.2mg per g dry sediment was stably retained. Concomitant addition of oleophilic fertilizer led to higher initial retention, as 24% of the kerosene remained after 2 days in the presence of a modified, cold-climate adapted version of the well-known Inipol EAP 22 bioremediation agent. In these enclosures, which showed an increase in hydrocarbon-degrader counts from 6.5 x 10(3) to 4.1 x 10(7) per g dry sediment within 8 days, a 17% contribution by biodegradation to subsequent hydrocarbon removal was estimated. Stimulation in hydrocarbon-degrader counts in fertilizer-alone control enclosures was indistinguishable from the stimulation observed with both kerosene and fertilizer present, suggesting that the dynamics in numbers of hydrocarbon-degrading bacteria was primarily impacted by the bioremediation agent.

  15. An Active Heater Control Concept to Meet IXO Type Mirror Module Thermal-Structural Distortion Requirement

    NASA Technical Reports Server (NTRS)

    Choi, Michael

    2013-01-01

    Flight mirror assemblies (FMAs) of large telescopes, such as the International X-ray Observatory (IXO), have very stringent thermal-structural distortion requirements. The spatial temperature gradient requirement within a FMA could be as small as 0.05 C. Con ventionally, heaters and thermistors are attached to the stray light baffle (SLB), and centralized heater controllers (i.e., heater controller boards located in a large electronics box) are used. Due to the large number of heater harnesses, accommodating and routing them is extremely difficult. The total harness length/mass is very large. This innovation uses a thermally conductive pre-collimator to accommodate heaters and a distributed heater controller approach. It minimizes the harness length and mass, and reduces the problem of routing and accommodating them. Heaters and thermistors are attached to a short (4.67 cm) aluminum portion of the pre-collimator, which is thermally coupled to the SLB. Heaters, which have a very small heater power density, and thermistors are attached to the exterior of all the mirror module walls. The major portion (23.4 cm) of the pre-collimator for the middle and outer modules is made of thin, non-conductive material. It minimizes the view factors from the FMA and heated portion of the precollimator to space. It also minimizes heat conduction from one end of the FMA to the other. Small and multi-channel heater controllers, which have adjustable set points and internal redundancy, are used. They are mounted to the mechanical support structure members adjacent to each module. The IXO FMA, which is 3.3 m in diameter, is an example of a large telescope. If the heater controller boards are centralized, routing and accommodating heater harnesses is extremely difficult. This innovation has the following advantages. It minimizes the length/mass of the heater harness between the heater controllers and heater circuits. It reduces the problem of routing and accommodating the harness on the

  16. High Efficiency Water Heating Technology Development Final Report, Part II: CO 2 and Absorption-Based Residential Heat Pump Water Heater Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gluesenkamp, Kyle R.; Abdelaziz, Omar; Patel, Viral K.

    2017-05-01

    The two objectives of this project were to 1.demonstrate an affordable path to an ENERGY STAR qualified electric heat pump water heater (HPWH) based on low-global warming potential (GWP) CO 2 refrigerant, and 2.demonstrate an affordable path to a gas-fired absorption-based heat pump water heater with a gas energy factor (EF) greater than 1.0. The first objective has been met, and the project has identified a promising low-cost option capable of meeting the second objective. This report documents the process followed and results obtained in addressing these objectives.

  17. Kerosene-a toddler's sin: A five years study at tertiary care hospital in western India.

    PubMed

    Parekh, Utsav; Gupta, Sanjay

    2017-04-01

    Acute kerosene poisoning is a preventable health problem in children perceived mainly in developing countries. It influences socioeconomic and cultural status of country due to its contribution in morbidity and mortality. As kerosene is widely used as household energy source in India at rural areas as well as urban, it accounts for significant number of poisoning cases mainly accidental in manner. As there are only handful studies from India on kerosene poisoning in children, we planned this study to evaluate incidence of kerosene poisoning in Western Indian population and its clinico-epidemiotoxicological profile. In this retrospective cross-sectional study, we collected data of all the cases of kerosene poisoning diagnosed during five years from 2009 to 2013 at Shri Krishna hospital situated at Karamsad, Gujarat state of Western India. We observed among total 42 cases, all victims were under 3 years of age. Evening in summer months, rural areas, storage of kerosene in household containers, inadequate parental supervision and door-to-hospitalization period emerged as most serious associated factors. Fever, cough, vomiting, tachypnoea and leucocytosis were commonest manifestations while pneumonia was the most common complication. Signs of central nervous system involvement, leucocytosis and vomiting were significantly correlated with pneumonia. Deaths occurred due to pneumonia. Early diagnosis and treatment of pneumonia may reduce mortality and recommendations are made to reduce the incidence of kerosene poisoning. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  18. Clinical finding and outcome in suicidal attempt due to intravenous injection of kerosene.

    PubMed

    Amiri, Aref Hosseinian; Tarrahi, Mohammad Javad; Rafiei, Alireza

    2009-03-01

    The aim of this study was to describe the clinical findings and outcome in suicidal attempted due to intravenous injection of kerosene. This case series study was conducted in the Department of Internal Medicine, Shohada Ashayer Hospital, Khorramabad, Iran during 8 years. Ten IV drug addicts who intravenously injected themselves with Kerosene were collected. All patients admitted in ICU, completely monitored for cardiopulmonary status and consulted with pulmonologist, cardiologist, neurologist, anesthesiologist and dermatologist. Therapeutic decision including intubation, antibiotics therapy, and oxygen, correction of water and electrolyte disturbances was applied according patients condition. The data were analyzed with fisher-exact test. Nine (90%) patients were male, 1(10%) was female. All cases were attempted suicides and IV drug abusers. Mean age was 20.3 +/- 2 years. The patients' mean arrival time to the hospital after poisoning was 1.1 h. Death of 5(50%) patients was related to the higher doses (>5 mL) of intravenous injection of kerosene, the most clinical findings were related to pulmonary involvement with pulmonary edema and subsequent cardiac and neurological complications and phlebitis due to IV injection. Intravenous kerosene injection causes major injury to the lungs, the organ bearing the first capillary bed encountered. Other complications including cardiac and neurological seems to be related to severe hypoxia and other metabolic disturbances due to lung injury. The amounts of kerosene were major determinants of lethality. Early and aggressive supportive care might be conducive to a favorable outcome with minimal residual pulmonary squeal at least in patients with injection of less than 5 mL of kerosene.

  19. Kerosene-base fuels in small gasoline engines. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Failla, C.C.; Pouring, A.A.

    1991-01-01

    This document presents the results of an engineering study to demonstrate the technology for converting small gasoline spark-ignited engines, to burn kerosene type fuels to power small generators (0.5 to 3.0 kw). Commercially available (plus those in the developmental stage), reciprocating, two-stroke, four stroke and rotary engines were evaluated for their conversion potential. Unique combustion systems were identified and trade-off studies conducted on engine type, combustion systems, and modification required to burn kerosene type fuels, with special emphasis given to minimizing life cycle cost. Recommendations for the most feasible system are given.

  20. Metabolic and thyroidal response in air-breathing perch (Anabas testudineus) to water-borne kerosene.

    PubMed

    Peter, Valsa S; Joshua, Elizabeth K; Wendelaar Bonga, Sjoerd E; Peter, M C Subhash

    2007-01-01

    To address the physiological compensatory adaptations in air-breathing fish to a toxicant, we studied the metabolite pattern, serum and liver enzymes and thyroidal response in a tropical air-breathing perch, Anabas testudineus (kept at 30 degrees C in a 12-h L:D cycle) after exposing the fish for 48h to the water-soluble fraction of kerosene. The concentrations of serum glucose (P <0.05), triglycerides (P <0.01) and liver total protein (P <0.05) were significantly increased in kerosene-exposed fish. The serum urea level, however, remained unaffected. A significant (P <0.05) increase in liver RNA occurred without changing the liver DNA concentration. Kerosene exposure decreased the level of aspartate aminotransferase activities in serum (P <0.001) and liver (P <0.05) but it increased (P <0.05) the liver alanine aminotransferase activity without changing its activity in serum. The levels of serum (P <0.01) and liver (P <0.001) lactate dehydrogenase activity were declined and the serum (P <0.05) and liver (P <0.05) alkaline phosphatase activity levels were elevated in kerosene-treated fish. The nominated levels (3.33-6.66ml/L) of kerosene significantly (P <0.01) elevated the thyroxine (T(4)) titre, and reduced (P <0.05) the triiodothyronine (T(3)) titre. The fish pretreated with either T(3) or T(4) and exposed to kerosene had a metabolic and thyroidal response that differed from that in control fish treated with kerosene: no rise in serum glucose was observed, nor in triglycerides, total protein and RNA in the liver, whereas declined levels of T(4) and T(3) were observed. The upregulation of the thyroid along with the marked metabolite changes point to a positive involvement of thyroid in energy metabolism during kerosene exposure. This is consistent with the hypothesis that the fish thyroid responds to the action of petroleum products and influences the metabolic homeostasis of this air-breathing fish.

  1. Acid-catalyzed hydrogenation during kerosene hydrodewaxing over H/ZSM-5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Longstaff, D.C.; Hanson, F.V.

    1996-11-01

    Hydrogen addition to the products derived from cracking kerosene over H/ZSM-5 was observed at hydrogen pressures between 4.1-8.7 MPa and at 373-390{degrees}C. At low pressures, kerosene cracking over H/ZSM-5 yielded typical cracked products: aromatics, as well as low molecular weight saturates and olefins. Endothermic reactor temperature profiles were also observed, indicative of cracking reactions. At high hydrogen partial pressures product selectivity was altered in that kerosene cracking gave high yields of low molecular weight paraffins and low yields of olefins and aromatics. Reactor temperature profiles were exothermic, indicative of hydrocracking reactions. A mechanism for acid catalyzed hydrogenation is suggested. Althoughmore » hydrogenation was not observed at lower hydrogen pressures, hydrogen proved beneficial in maintaining catalyst activity at a stable level. Lost catalyst activity was restored by maintaining the catalyst under static hydrogen at 1.4 MPa and 370{degrees}C for 16h. 36 refs., 14 figs., 3 tabs.« less

  2. Structural Benchmark Creep Testing for the Advanced Stirling Convertor Heater Head

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Kalluri, Sreeramesh; Bowman, Randy R.; Shah, Ashwin R.

    2008-01-01

    The National Aeronautics and Space Administration (NASA) has identified the high efficiency Advanced Stirling Radioisotope Generator (ASRG) as a candidate power source for use on long duration Science missions such as lunar applications, Mars rovers, and deep space missions. For the inherent long life times required, a structurally significant design limit for the heater head component of the ASRG Advanced Stirling Convertor (ASC) is creep deformation induced at low stress levels and high temperatures. Demonstrating proof of adequate margins on creep deformation and rupture for the operating conditions and the MarM-247 material of construction is a challenge that the NASA Glenn Research Center is addressing. The combined analytical and experimental program ensures integrity and high reliability of the heater head for its 17-year design life. The life assessment approach starts with an extensive series of uniaxial creep tests on thin MarM-247 specimens that comprise the same chemistry, microstructure, and heat treatment processing as the heater head itself. This effort addresses a scarcity of openly available creep properties for the material as well as for the virtual absence of understanding of the effect on creep properties due to very thin walls, fine grains, low stress levels, and high-temperature fabrication steps. The approach continues with a considerable analytical effort, both deterministically to evaluate the median creep life using nonlinear finite element analysis, and probabilistically to calculate the heater head s reliability to a higher degree. Finally, the approach includes a substantial structural benchmark creep testing activity to calibrate and validate the analytical work. This last element provides high fidelity testing of prototypical heater head test articles; the testing includes the relevant material issues and the essential multiaxial stress state, and applies prototypical and accelerated temperature profiles for timely results in a

  3. Experimental Creep Life Assessment for the Advanced Stirling Convertor Heater Head

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Kalluri, Sreeramesh; Shah, Ashwin R.; Korovaichuk, Igor

    2010-01-01

    The United States Department of Energy is planning to develop the Advanced Stirling Radioisotope Generator (ASRG) for the National Aeronautics and Space Administration (NASA) for potential use on future space missions. The ASRG provides substantial efficiency and specific power improvements over radioisotope power systems of heritage designs. The ASRG would use General Purpose Heat Source modules as energy sources and the free-piston Advanced Stirling Convertor (ASC) to convert heat into electrical energy. Lockheed Martin Corporation of Valley Forge, Pennsylvania, is integrating the ASRG systems, and Sunpower, Inc., of Athens, Ohio, is designing and building the ASC. NASA Glenn Research Center of Cleveland, Ohio, manages the Sunpower contract and provides technology development in several areas for the ASC. One area is reliability assessment for the ASC heater head, a critical pressure vessel within which heat is converted into mechanical oscillation of a displacer piston. For high system efficiency, the ASC heater head operates at very high temperature (850 C) and therefore is fabricated from an advanced heat-resistant nickel-based superalloy Microcast MarM-247. Since use of MarM-247 in a thin-walled pressure vessel is atypical, much effort is required to assure that the system will operate reliably for its design life of 17 years. One life-limiting structural response for this application is creep; creep deformation is the accumulation of time-dependent inelastic strain under sustained loading over time. If allowed to progress, the deformation eventually results in creep rupture. Since creep material properties are not available in the open literature, a detailed creep life assessment of the ASC heater head effort is underway. This paper presents an overview of that creep life assessment approach, including the reliability-based creep criteria developed from coupon testing, and the associated heater head deterministic and probabilistic analyses. The approach also

  4. Cavity ignition of liquid kerosene in supersonic flow with a laser-induced plasma.

    PubMed

    Li, Xiaohui; Yang, Leichao; Peng, Jiangbo; Yu, Xin; Liang, Jianhan; Sun, Rui

    2016-10-31

    We have for the first time achieved cavity ignition and sustainable combustion of liquid kerosene in supersonic flow of Mach number 2.52 using a laser-induced plasma (LIP) on a model supersonic combustor equipped with dual cavities in tandem as flameholders. The liquid kerosene of ambient temperature is injected from the front wall of the upstream cavity, while the ignitions have been conducted in both cavities. High-speed chemiluminescence imaging shows that the flame kernel initiated in the downstream cavity can propagate contraflow into upstream cavity and establish full sustainable combustion. Based on the qualitative distribution of the kerosene vapor in the cavity, obtained using the kerosene planar laser-induced fluorescence technique, we find that the fuel atomization and evaporation, local hydrodynamic and mixing conditions in the vicinity of the ignition position and in the leading edge area of the cavity have combined effects on the flame kernel evolution and the eventual ignition results.

  5. Absorption and scattering of laser radiation by the diffusion flame of aviation kerosene

    NASA Astrophysics Data System (ADS)

    Gvozdev, S. V.; Glova, A. F.; Dubrovskii, V. Yu; Durmanov, S. T.; Krasyukov, A. G.; Lysikov, A. Yu; Smirnov, G. V.; Solomakhin, V. B.

    2012-04-01

    The absorption coefficient of the radiation of a repetitively pulsed Nd : YAG laser with an average output power up to 6 W and of a cw ytterbium optical fibre laser with an output power up to 3 kW was measured in the diffusion flame of aviation kerosene burning on a free surface in the atmospheric air. The absorption coefficient as a function of flame length, radiation power, and radiation intensity, which was varied in the ~103 — 5×104 W cm-2 range, was obtained for two distances (1 and 2 cm) between the laser beam axis and the surface. The coefficient of radiation absorption by kerosene flame was compared with that in ethanol and kerosene — ethanol mixture flames. The radiation power scattered by a small segment of the kerosene flame irradiated by Nd : YAG laser radiation was measured as a function of longitudinal and azimuthal coordinates. An estimate was made of the total scattered radiation power.

  6. Solar air heaters and their applications

    NASA Technical Reports Server (NTRS)

    Selcuk, M. K.

    1977-01-01

    The solar air heater appears to be the most logical choice, as far as the ultimate application of heating air to maintain a comfortable environment is concerned. One disadvantage of solar air heaters is the need for handling larger volumes of air than liquids due to the low density of air as a working substance. Another disadvantage is the low thermal capacity of air. In cases where thermal storage is needed, water is superior to air. Design variations of solar air heaters are discussed along with the calculation of the efficiency of a flat plate solar air heater, the performance of various collector types, and the applications of solar air heaters. Attention is given to collectors with nonporous absorber plates, collectors with porous absorbers, the performance of flat plate collectors with finned absorbers, a wire mesh absorber, and an overlapped glass plate air heater.

  7. Fire monitoring from space: from research to operation

    NASA Astrophysics Data System (ADS)

    Pergola, Nicola; Filizzola, Carolina; Corrado, Rosita; Coviello, Irina; lacava, Teodosio; Marchese, Francesco; Mazzeo, Giuseppe; Paciello, Rossana; Tramutoli, Valerio

    2013-04-01

    Each summer fires rage through European forests, burning hundreds of thousands of hectares per year, as a result of the many (up to 60000) forest fires that usually occur annually in Europe. Fires can threaten public health and safety, destroy property and cause economic damages. Despite of their medium extension (the average burnt area is less than 6 ha), much smaller if compared with other regions like the USA and Canada, the number of simultaneous active fires in Europe can be very high, fomented by weather conditions that, especially in summer times and for countries of South Europe, are particularly favourable to a rapid and dramatic development of flames. Fires still are not only a social problem, but also an environmental emergency, producing a continuous impoverishment of forests and possibly indirectly triggering other natural hazards (e.g. making slopes, without the trees action, more prone to landslides). Additionally, there is a general concern about the loss of biodiversity and the contribution to land degradation that fires may cause. Earth Observation satellite systems have been largely tested for fire detection and monitoring from space. Their spectral capability, synoptic view and revisit times can offer an added value in the operational use not only in real time, during fires fighting activities, but also in near-real or delay time during the phases of risk management and mitigation. However, the practice of an actual operational use of satellite products by end-users is still not usual at European level. This work is based on the experience carried out jointly by CNR-IMAA and the National Civil Protection Department (DPC), in the framework of a five-year agreement in which the operational use of an Earth observation satellite system for fires spotting and monitoring is tested. Satellite-based products, developed not only for detecting fires but also for continuously monitoring their evolution in time domain, have been provided to Civil Protection

  8. Accelerated Life Structural Benchmark Testing for a Stirling Convertor Heater Head

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Kantzos, Pete T.

    2006-01-01

    For proposed long-duration NASA Space Science missions, the Department of Energy, Lockheed Martin, Infinia Corporation, and NASA Glenn Research Center are developing a high-efficiency, 110 W Stirling Radioisotope Generator (SRG110). A structurally significant limit state for the SRG110 heater head component is creep deformation induced at high material temperature and low stress level. Conventional investigations of creep behavior adequately rely on experimental results from uniaxial creep specimens, and a wealth of creep data is available for the Inconel 718 material of construction. However, the specified atypical thin heater head material is fine-grained with a heat treatment that limits precipitate growth, and little creep property data for this microstructure is available in the literature. In addition, the geometry and loading conditions apply a multiaxial stress state on the component, far from the conditions of uniaxial testing. For these reasons, an extensive experimental investigation is ongoing to aid in accurately assessing the durability of the SRG110 heater head. This investigation supplements uniaxial creep testing with pneumatic testing of heater head-like pressure vessels at design temperature with stress levels ranging from approximately the design stress to several times that. This paper presents experimental results, post-test microstructural analyses, and conclusions for four higher-stress, accelerated life tests. Analysts are using these results to calibrate deterministic and probabilistic analytical creep models of the SRG110 heater head.

  9. Infrared Heaters

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The heating units shown in the accompanying photos are Panelbloc infrared heaters, energy savers which burn little fuel in relation to their effective heat output. Produced by Bettcher Manufacturing Corporation, Cleveland, Ohio, Panelblocs are applicable to industrial or other facilities which have ceilings more than 12 feet high, such as those pictured: at left the Bare Hills Tennis Club, Baltimore, Maryland and at right, CVA Lincoln- Mercury, Gaithersburg, Maryland. The heaters are mounted high above the floor and they radiate infrared energy downward. Panelblocs do not waste energy by warming the surrounding air. Instead, they beam invisible heat rays directly to objects which absorb the radiation- people, floors, machinery and other plant equipment. All these objects in turn re-radiate the energy to the air. A key element in the Panelbloc design is a coating applied to the aluminized steel outer surface of the heater. This coating must be corrosion resistant at high temperatures and it must have high "emissivity"-the ability of a surface to emit radiant energy. The Bettcher company formerly used a porcelain coating, but it caused a production problem. Bettcher did not have the capability to apply the material in its own plant, so the heaters had to be shipped out of state for porcelainizing, which entailed extra cost. Bettcher sought a coating which could meet the specifications yet be applied in its own facilities. The company asked The Knowledge Availability Systems Center, Pittsburgh, Pennsylvania, a NASA Industrial Applications Center (IAC), for a search of NASA's files

  10. 33 CFR 149.413 - On a manned deepwater port, what spaces require a fixed fire extinguishing system?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... capacity of more than 200 cubic feet, and similar spaces containing flammable liquids. (b) Galley ranges or... spaces require a fixed fire extinguishing system? 149.413 Section 149.413 Navigation and Navigable Waters... manned deepwater port, what spaces require a fixed fire extinguishing system? The manned deepwater port...

  11. 33 CFR 149.413 - On a manned deepwater port, what spaces require a fixed fire extinguishing system?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... capacity of more than 200 cubic feet, and similar spaces containing flammable liquids. (b) Galley ranges or... spaces require a fixed fire extinguishing system? 149.413 Section 149.413 Navigation and Navigable Waters... manned deepwater port, what spaces require a fixed fire extinguishing system? The manned deepwater port...

  12. 33 CFR 149.413 - On a manned deepwater port, what spaces require a fixed fire extinguishing system?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... capacity of more than 200 cubic feet, and similar spaces containing flammable liquids. (b) Galley ranges or... spaces require a fixed fire extinguishing system? 149.413 Section 149.413 Navigation and Navigable Waters... manned deepwater port, what spaces require a fixed fire extinguishing system? The manned deepwater port...

  13. 33 CFR 149.413 - On a manned deepwater port, what spaces require a fixed fire extinguishing system?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... capacity of more than 200 cubic feet, and similar spaces containing flammable liquids. (b) Galley ranges or... spaces require a fixed fire extinguishing system? 149.413 Section 149.413 Navigation and Navigable Waters... manned deepwater port, what spaces require a fixed fire extinguishing system? The manned deepwater port...

  14. 33 CFR 149.413 - On a manned deepwater port, what spaces require a fixed fire extinguishing system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... capacity of more than 200 cubic feet, and similar spaces containing flammable liquids. (b) Galley ranges or... spaces require a fixed fire extinguishing system? 149.413 Section 149.413 Navigation and Navigable Waters... manned deepwater port, what spaces require a fixed fire extinguishing system? The manned deepwater port...

  15. Development of the International Space Station (ISS) Fine Water Mist (FWM) Portable Fire Extinguisher

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle; Graf, John; Carlile, Christie; Young, GIna

    2012-01-01

    The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational concerns with the emergency breathing equipment and the carbon dioxide extinguisher. The toxicity of the carbon dioxide requires the crew members to have an oxygen supply present during a fire event, therefore inherently creating an unsafe environment. The FWM PFE extinguishes a fire without creating a hazardous breathing environment for crew members. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, as well as discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.

  16. Heater Development, Fabrication, and Testing: Analysis of Fabricated Heaters

    NASA Technical Reports Server (NTRS)

    Bragg-Sitton, S. M.; Dickens, R. E.; Farmer, J. T.; Davis, J. D.; Adams, M. R.; Martin, J. J.; Webster, K. L.

    2008-01-01

    Thermal simulators (highly designed heater elements) developed at the Early Flight Fission Test Facility (EFF-TF) are used to simulate the heat from nuclear fission in a variety of reactor concepts. When inserted into the reactor geometry, the purpose of the thermal simulators is to deliver thermal power to the test article in the same fashion as if nuclear fuel were present. Considerable effort has been expended to mimic heat from fission as closely as possible. To accurately represent the fuel, the simulators should be capable of matching the overall properties of the nuclear fuel rather than simply matching the fuel temperatures. This includes matching thermal stresses in the pin, pin conductivities, total core power, and core power profile (axial and radial). This Technical Memorandum discusses the historical development of the thermal simulators used in nonnuclear testing at the EFF-TF and provides a basis for the development of the current series of thermal simulators. The status of current heater fabrication and testing is assessed, providing data and analyses for both successes and failures experienced in the heater development and testing program.

  17. [Study on rapid determination and analysis of rocket kerosene by near infrared spectrum and chemometrics].

    PubMed

    Xia, Ben-Li; Cong, Ji-Xin; Li, Xia; Wang, Xuan-Jun

    2011-06-01

    The rocket kerosene quality properties such as density, distillation range, viscosity and iodine value were successfully measured based on their near-infrared spectrum (NIRS) and chemometrics. In the present paper, more than 70 rocket kerosene samples were determined by near infrared spectrum, the models were built using the partial least squares method within the appropriate wavelength range. The correlation coefficients (R2) of every rocket kerosene's quality properties ranged from 0.862 to 0.999. Ten unknown samples were determined with the model, and the result showed that the prediction accuracy of near infrared spectrum method accords with standard analysis requirements. The new method is well suitable for replacing the traditional standard method to rapidly determine the properties of the rocket kerosene.

  18. 26 CFR 48.4082-3 - Diesel fuel and kerosene; visual inspection devices. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; visual inspection devices. [Reserved] 48.4082-3 Section 48.4082-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-3 Diesel fuel and kerosene...

  19. 26 CFR 48.4082-3 - Diesel fuel and kerosene; visual inspection devices. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; visual inspection devices. [Reserved] 48.4082-3 Section 48.4082-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-3 Diesel fuel and kerosene...

  20. 26 CFR 48.4082-3 - Diesel fuel and kerosene; visual inspection devices. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; visual inspection devices. [Reserved] 48.4082-3 Section 48.4082-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-3 Diesel fuel and kerosene...

  1. 26 CFR 48.4082-3 - Diesel fuel and kerosene; visual inspection devices. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; visual inspection devices. [Reserved] 48.4082-3 Section 48.4082-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... Vehicles, Tires, Tubes, Tread Rubber, and Taxable Fuel Taxable Fuel § 48.4082-3 Diesel fuel and kerosene...

  2. Fuel oil and kerosene sales, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-01-22

    Despite the rise in petroleum products prices, a colder-than-normal winter in the latter part of 1989 spurred an increase in demand for distillate fuel oils. The shipping and electric utilities industries contributed to a significant rise in demand for both distillate and residual fuels oils in 1989. A total of 72.9 billion gallons of fuel oil and kerosene were sold to consumers in 1989, an increase of 3.0 percent over 1988 sales volumes. Of all fuel oil sold during 1989, distillate fuel oil accounted for 68.3 percent, which was an increase over 1988 when distillate fuel oil accounted for 67.2more » percent of all fuel oil products sold in the United States. Residual fuel oil's share of total fuel oil sold fell slightly to 29.9 percent from 30.7 percent in 1988. Kerosene followed with a 1.8 percent share, also falling from the previous year when it accounted for a 2.1 percent share of total fuel oil sold. 3 figs., 24 tabs.« less

  3. Parallel heater system for subsurface formations

    DOEpatents

    Harris, Christopher Kelvin [Houston, TX; Karanikas, John Michael [Houston, TX; Nguyen, Scott Vinh [Houston, TX

    2011-10-25

    A heating system for a subsurface formation is disclosed. The system includes a plurality of substantially horizontally oriented or inclined heater sections located in a hydrocarbon containing layer in the formation. At least a portion of two of the heater sections are substantially parallel to each other. The ends of at least two of the heater sections in the layer are electrically coupled to a substantially horizontal, or inclined, electrical conductor oriented substantially perpendicular to the ends of the at least two heater sections.

  4. Determination of sulfur in kerosene by combustion and molecular absorption spectrometry in the gas phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruschak, M.L.; Syty, A.

    1982-08-01

    A technique of nonflame molecular adsorption in the gas phase developed for the determination of sulfite trapped in tetrachloromercurate, is described herein for application to the determination of total sulfur in kerosene. The burner head is removed from the atomic absorption spectrometer and replaced with a flow-through absorption cell. A special reaction vessel is used to evolve SO/sub 2/ from the sulfite in a precise and convenient manner. The transient absorbance caused by the SO/sub 2/, as it is carried through the absorption cell, is measured. Both spiked and unspiked samples of kerosene were analyzed, and the reproducibility of themore » repeated runs is evidenced by a relative standard deviation from the mean of 5% for the unspiked kerosene and 4% for the spiked kerosene. If the detection level is defined as that concentration of S which gives a % S twice the standard deviation from the mean yields, the detection limit for the present method is 0.002% S by weight in kerosene.« less

  5. Influence of the input database in detecting fire space-time clusters

    NASA Astrophysics Data System (ADS)

    Pereira, Mário; Costa, Ricardo; Tonini, Marj; Vega Orozco, Carmen; Parente, Joana

    2015-04-01

    Fire incidence variability is influenced by local environmental variables such as topography, land use, vegetation and weather conditions. These induce a cluster pattern of the fire events distribution. The space-time permutation scan statistics (STPSS) method developed by Kulldorff et al. (2005) and implemented in the SaTScanTM software (http://www.satscan.org/) proves to be able to detect space-time clusters in many different fields, even when using incomplete and/or inaccurate input data. Nevertheless, the dependence of the STPSS method on the different characteristics of different datasets describing the same environmental phenomenon has not been studied yet. In this sense, the objective of this study is to assess the robustness of the STPSS for detecting real clusters using different input datasets and to justify the obtained results. This study takes advantage of the existence of two very different official fire datasets currently available for Portugal, both provided by the Institute for the Conservation of Nature and Forests. The first one is the aggregated Portuguese Rural Fire Database PRFD (Pereira et al., 2011), which is based on ground measurements and provides detailed information about the ignition and extinction date/time and the area burnt by each fire in forest, scrubs and agricultural areas. However, in the PRFD, the fire location of each fire is indicated by the name of smallest administrative unit (the parish) where the ignition occurred. Consequently, since the application of the STPSS requires the geographic coordinates of the events, the centroid of the parishes was considered. The second fire dataset is the national mapping burnt areas (NMBA), which is based on satellite measurements and delivered in shape file format. The NMBA provides a detailed spatial information (shape and size of each fire) but the temporal information is restricted to the year of occurrence. Besides these differences, the two datasets cover different periods, they

  6. Varying properties along lengths of temperature limited heaters

    DOEpatents

    Vinegar, Harold J [Bellaire, TX; Xie, Xueying [Houston, TX; Miller, David Scott [Katy, TX; Ginestra, Jean Charles [Richmond, TX

    2011-07-26

    A system for heating a subsurface formation is described. The system includes an elongated heater in an opening in the formation. The elongated heater includes two or more portions along the length of the heater that have different power outputs. At least one portion of the elongated heater includes at least one temperature limited portion with at least one selected temperature at which the portion provides a reduced heat output. The heater is configured to provide heat to the formation with the different power outputs. The heater is configured so that the heater heats one or more portions of the formation at one or more selected heating rates.

  7. The climate space of fire regimes in north-western North America

    USGS Publications Warehouse

    Whitman, Ellen; Batllori, Enric; Parisien, Marc-André; Miller, Carol; Coop, Jonathan D.; Krawchuk, Meg A.; Chong, Geneva W.; Haire, Sandra L.

    2015-01-01

    Aim. Studies of fire activity along environmental gradients have been undertaken, but the results of such studies have yet to be integrated with fire-regime analysis. We characterize fire-regime components along climate gradients and a gradient of human influence. Location. We focus on a climatically diverse region of north-western North America extending from northern British Columbia, Canada, to northern Utah and Colorado, USA.Methods. We used a multivariate framework to collapse 12 climatic variables into two major climate gradients and binned them into 73 discrete climate domains. We examined variation in fire-regime components (frequency, size, severity, seasonality and cause) across climate domains. Fire-regime attributes were compiled from existing databases and Landsat imagery for 1897 large fires. Relationships among the fire-regime components, climate gradients and human influence were examined through bivariate regressions. The unique contribution of human influence was also assessed.Results. A primary climate gradient of temperature and summer precipitation and a secondary gradient of continentality and winter precipitation in the study area were identified. Fire occupied a distinct central region of such climate space, within which fire-regime components varied considerably. We identified significant interrelations between fire-regime components of fire size, frequency, burn severity and cause. The influence of humans was apparent in patterns of burn severity and ignition cause.Main conclusions. Wildfire activity is highest where thermal and moisture gradients converge to promote fuel production, flammability and ignitions. Having linked fire-regime components to large-scale climate gradients, we show that fire regimes – like the climate that controls them – are a part of a continuum, expanding on models of varying constraints on fire activity. The observed relationships between fire-regime components, together with the distinct role of climatic

  8. Build Your Own Solar Air Heater.

    ERIC Educational Resources Information Center

    Conservation and Renewable Energy Inquiry and Referral Service (DOE), Silver Spring, MD.

    The solar air heater is a simple device for catching some of the sun's energy to heat a home. Procedures for making and installing such a heater are presented. Included is a materials list, including tools needed for constructing the heater, sources for obtaining further details, and a list of material specifications. (JN)

  9. Absorption and scattering of laser radiation by the diffusion flame of aviation kerosene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gvozdev, S V; Glova, A F; Dubrovskii, V Yu

    2012-04-30

    The absorption coefficient of the radiation of a repetitively pulsed Nd : YAG laser with an average output power up to 6 W and of a cw ytterbium optical fibre laser with an output power up to 3 kW was measured in the diffusion flame of aviation kerosene burning on a free surface in the atmospheric air. The absorption coefficient as a function of flame length, radiation power, and radiation intensity, which was varied in the {approx}10{sup 3} - 5 Multiplication-Sign 10{sup 4} W cm{sup -2} range, was obtained for two distances (1 and 2 cm) between the laser beammore » axis and the surface. The coefficient of radiation absorption by kerosene flame was compared with that in ethanol and kerosene - ethanol mixture flames. The radiation power scattered by a small segment of the kerosene flame irradiated by Nd : YAG laser radiation was measured as a function of longitudinal and azimuthal coordinates. An estimate was made of the total scattered radiation power.« less

  10. Black Carbon and Kerosene Lighting: An Opportunity for Rapid Action on Climate Change and Clean Energy for Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobson, Arne; Bond, Tami C.; Lam, Nicholoas L.

    2013-04-15

    Replacing inefficient kerosene lighting with electric lighting or other clean alternatives can rapidly achieve development and energy access goals, save money and reduce climate warming. Many of the 250 million households that lack reliable access to electricity rely on inefficient and dangerous simple wick lamps and other kerosene-fueled light sources, using 4 to 25 billion liters of kerosene annually to meet basic lighting needs. Kerosene costs can be a significant household expense and subsidies are expensive. New information on kerosene lamp emissions reveals that their climate impacts are substantial. Eliminating current annual black carbon emissions would provide a climate benefitmore » equivalent to 5 gigatons of carbon dioxide reductions over the next 20 years. Robust and low-cost technologies for supplanting simple wick and other kerosene-fueled lamps exist and are easily distributed and scalable. Improving household lighting offers a low-cost opportunity to improve development, cool the climate and reduce costs.« less

  11. Effects of diesel and kerosene on germination and growth of coastal wetland plant species.

    PubMed

    Kim, Kee Dae

    2014-11-01

    This study aims to investigate effects of diesel and kerosene on seed germination and seedling growth among coastal wetland plants to select species that can be used for the restoration and revegetation of oil-polluted habitats. Tests on 51 species were performed in Petri dishes containing 0 %, 6 %, 12 %, and 18 % diesel, 20 %, 40 %, and 60 % kerosene; each treatment combination was replicated five times with 20 seeds in each Petri dish. All dishes were held in a growth chamber with 20°C day of 12 h/15°C night of 12 h in 80 % humidity for 20 days for calculating the germination percentage, seedling weight, and seedling vitality. The germination percentage of Rumex stenophyllus decreased significantly in diesel and kerosene treatments. The weights of seedlings treated with diesel and kerosene either increased or decreased in comparison with controls depending on the species. Vitality percentage values were high for seedlings of Chenopodium ficifolium. Thus, herbaceous plant responses to oil treatments are species-specific.

  12. 49 CFR 393.77 - Heaters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... source and the heater. (13) “Tell-tale” indicators. Heaters subject to paragraph (c)(14) of this section and not provided with automatic controls shall be provided with “tell-tale” means to indicate to the...

  13. Evaluation of the Improved Flameless Ration Heater

    DTIC Science & Technology

    2001-12-01

    THROUGH SCIENCE TECHNICAL REPORT NATICKjTR.02/004 AD. _____ _ EVALUATION OF THE IMPROVED FLAMELESS RATION HEATER by Wendy K. Johnson and F...From- To) 21-12-2001 Final August 2000 - August 2001 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER EVALUATION OF THE IMPROVED FLAMELESS RATION HEATER...was conducted at Fort Wainwright, AK to evaluate two prototype heaters and a modified version of the current Flameless Ration Heater (FRH). The

  14. Tolerance of cultivated and wild plants of different taxonomy to soil contamination by kerosene.

    PubMed

    Sharonova, Natalia; Breus, Irina

    2012-05-01

    In laboratory experiments on leached chernozem contaminated by kerosene (1-15 wt.%), germination of 50 plants from 21 families (cultivated and wild, annual and perennial, mono- and dicotyledonous) as affected by kerosene type and concentration and plant features was determined. Tested plants formed three groups: more tolerant, less tolerant, and intolerant, in which relative germination was more than 70%, 30-70% and less than 30%, respectively. As parameters of soil phytotoxicity, effective kerosene concentrations (EC) causing germination depression of 10%, 25% and 50% were determined. EC values depended on the plant species and varied in a wide range of kerosene concentrations: 0.02-7.3% (EC(10)), 0.05-8.1% (EC(25)), and 0.2-12.7% (EC(50)). The reported data on germination in soils contaminated by oil and petrochemicals were generalized. The comparison showed that at very high contamination levels (10 and 15%) kerosene was 1.3-1.6 times more phytotoxic than diesel fuel and 1.3-1.4 times more toxic than crude oil, and at low (1 and 2%) and medium (3 and 5%) levels the toxicity of these contaminants was close differing by a factor of 1.1-1.2. Tolerance of plants to soil contamination had a species-specific nature and, on the average, decreased in the following range of families: Fabaceae (germination decrease of 10-60% as compared to an uncontaminated control)>Brassicaceae (5-70%)>Asteraceae (25-95%)>Poaceae (10-100%). The monocotyledonous species tested were characterized as medium- and low-stable to contamination, whereas representatives of dicotyledonous plants were met in all groups of tolerance. Tested wild plants, contrary to reference data on oil toxicity, were more sensitive to kerosene than cultivated. No correlation was observed between degree of plant tolerance to kerosene and mass of seeds. The evidence indicates factors as structure and properties of testa, structure of germ, type of storage compounds, and type of seed germination (underground or

  15. Risk factors for kerosene stove explosion burns seen at Kenyatta National Hospital in Kenya.

    PubMed

    Ombati, Alex N; Ndaguatha, Peter L W; Wanjeri, Joseph K

    2013-05-01

    The kerosene stove is a common cooking appliance in lower and middle income households in Kenya and if it explodes, life threatening thermal burn injuries may be sustained by those using the appliance. Women tend to be victims more frequently since traditionally they are the ones who are involved in cooking. The aim of this study was to determine risk factors predisposing to kerosene stove explosion burns seen at Kenyatta National Hospital. The study was a prospective longitudinal descriptive study carried out at the Kenyatta National Hospital. Forty-eight patients who met the inclusion criteria were recruited into the study over a period of 6 months from November 2010 to April 2011 and the data was collected using a structured questionnaire. The analysis, using SPSS version 17.0 was done by associating occurrence of injury to: age, sex, socioeconomic status and level of education of patient. Charts and tables were used to present the results. The mean age of patients who sustained kerosene stove explosion burns was 23.6 years (SD ± 11.7) with the commonest age group being 20-39 years. More females were affected than males by a ratio of 7:3 and ninety two percent of those who sustained these burns were either from poor or lower middle socio-economic class. Stove explosions occurred mainly during cooking and when kerosene refill was being done. Most of the patients (63%) reported having bought kerosene from fuel vendors and almost all explosions were caused by the wick type of stove (98%). Young females from poor socioeconomic background were found to be at a higher risk for kerosene stove explosion burns. The wick stove is a common cause of burns especially when users unwittingly refill it with kerosene when already lit resulting in an explosion. Prevention can be done through evidence based public health education targeting the groups at risk and enactment of relevant laws. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  16. Heater Validation for the NEXT-C Hollow Cathodes

    NASA Technical Reports Server (NTRS)

    Verhey, Timothy R.; Soulas, George C.; Mackey, Jonathan Ar.

    2017-01-01

    Swaged cathode heaters whose design was successfully demonstrated under a prior flight project are to be provided by the NASA Glenn Research Center for the NEXT-C ion thruster being fabricated by Aerojet Rocketdyne. Extensive requalification activities were performed to validate process controls that had to be re-established or revised because systemic changes prevented reuse of the past approaches. A development batch of heaters was successfully fabricated based on the new process controls. Acceptance and cyclic life testing of multiple discharge and neutralizer sized heaters extracted from the development batch was initiated in August, 2016, with the last heater completing testing in April, 2017. Cyclic life testing results substantially exceeded the NEXT-C thruster requirement as well as all past experience for GRC fabricated units. The heaters demonstrated ultimate cyclic life capability of 19050 to 33500 cycles. A qualification batch of heaters is now being fabricated using the finalized process controls. A set of six heaters will be acceptance and cyclic tested to verify conformance to the behavior observed with the development heaters. The heaters for flight use will be then be provided to the contractor. This paper summarizes the fabrication process control activities and the acceptance and life testing of the development heater units.

  17. Heater Validation for the NEXT-C Hollow Cathodes

    NASA Technical Reports Server (NTRS)

    Verhey, Timothy R.; Soulas, George C.; Mackey, Jonathan A.

    2018-01-01

    Swaged cathode heaters whose design was successfully demonstrated under a prior flight project are to be provided by the NASA Glenn Research Center for the NEXT-C ion thruster being fabricated by Aerojet Rocketdyne. Extensive requalification activities were performed to validate process controls that had to be re-established or revised because systemic changes prevented reuse of the past approaches. A development batch of heaters was successfully fabricated based on the new process controls. Acceptance and cyclic life testing of multiple discharge and neutralizer sized heaters extracted from the development batch was initiated in August, 2016, with the last heater completing testing in April, 2017. Cyclic life testing results substantially exceeded the NEXT-C thruster requirement as well as all past experience for GRC-fabricated units. The heaters demonstrated ultimate cyclic life capability of 19050 to 33500 cycles. A qualification batch of heaters is now being fabricated using the finalized process controls. A set of six heaters will be acceptance and cyclic tested to verify conformance to the behavior observed with the development heaters. The heaters for flight use will be then be provided to the contractor from the remainder of the qualification batch. This paper summarizes the fabrication process control activities and the acceptance and life testing of the development heater units.

  18. Analysis of copper mixed kerosene servotherm in EDM of Monel 400™

    NASA Astrophysics Data System (ADS)

    Anandakumar, P. A.; Molla, Baya; Biruke, Fisha; Aravind, S.

    2017-05-01

    Powder mixed electro discharge machine process (PMEDM) is a hybrid machine process where a conductive powders is mixed to the dielectric fluid to facilitate effective machining of advanced material. This present study focused on performance of copper mixed kerosene servotherm as dielectric medium in EDM of Monel 400TM. The ratio of kerosene sevothermis 75 : 25. The copper powder was mixed with dielectric medium of kerosene servothem of 6g, 8g and 10 g respectively. This mixture was analyzed using different current rate of 8 amps, 10 amps and 12 amps to know the performance characteristics by using material removal rate, tool wear rate, diameter overcut, surface finish and dimensional accuracy. Based on the experimental investigation it is concluded that copper powder of 10g with 10 amps performed well than that of all other parameters.

  19. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...

  20. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...

  1. Convective heater

    DOEpatents

    Thorogood, Robert M.

    1986-01-01

    A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

  2. Convective heater

    DOEpatents

    Thorogood, Robert M.

    1983-01-01

    A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

  3. Convective heater

    DOEpatents

    Thorogood, R.M.

    1983-12-27

    A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation. 14 figs.

  4. 26 CFR 48.6427-9 - Diesel fuel and kerosene; claims by registered ultimate vendors (farming and State use).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; claims by registered... Manufacturers Taxes § 48.6427-9 Diesel fuel and kerosene; claims by registered ultimate vendors (farming and... taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section 6427(l)(5...

  5. 26 CFR 48.6427-9 - Diesel fuel and kerosene; claims by registered ultimate vendors (farming and State use).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; claims by registered... Manufacturers Taxes § 48.6427-9 Diesel fuel and kerosene; claims by registered ultimate vendors (farming and... taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section 6427(l)(5...

  6. 26 CFR 48.6427-9 - Diesel fuel and kerosene; claims by registered ultimate vendors (farming and State use).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; claims by registered... Manufacturers Taxes § 48.6427-9 Diesel fuel and kerosene; claims by registered ultimate vendors (farming and... taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section 6427(l)(5...

  7. 26 CFR 48.6427-9 - Diesel fuel and kerosene; claims by registered ultimate vendors (farming and State use).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; claims by registered... Manufacturers Taxes § 48.6427-9 Diesel fuel and kerosene; claims by registered ultimate vendors (farming and... taxed diesel fuel and kerosene may claim the income tax credits or payments allowed by section 6427(l)(5...

  8. Resistance Heater Helps Stirling-Engine Research

    NASA Technical Reports Server (NTRS)

    Hoehn, F. W.

    1982-01-01

    Stirling engine heater head consists of 18 double-turn coils of tubing, each of which is tightly wrapped with resistance-heating element, through which working gas flows. Coils form a toroid about periphery of heater-head body. With new resistance heater, total circuit resistance can be selected independently of tube geometry by changing size of wires and/or number of wire wraps around each tube.

  9. Infrared fiber-optic fire sensors - Concepts and designs for Space Station applications

    NASA Technical Reports Server (NTRS)

    Tapphorn, Ralph M.; Porter, Alan R.

    1990-01-01

    Various design configurations used for testing IR fiber-optic (IFO) fire-sensor concepts are presented. Responsibility measurements conducted to select the best concept are reviewed. The results indicate that IFO fire-sensor systems based on distributed fiber sensors are feasible for future aerospace applications. For Space Station Freedom, these systems offer alternative fire detectors for monitoring areas within equipment or stage compartments where the ventilation may be inadequate for proper operation of smoke detectors. They also allow a large number of areas to be monitored by a single central detector unit, which reduces the associated cost and weight.

  10. Exposure to open-fire cooking and cognitive performance in children.

    PubMed

    Munroe, Robert L; Gauvain, Mary

    2012-01-01

    We reexamined field data on cognitive performance in light of recent research that shows open-fire cooking--with its emission of harmful substances--to pose a risk to healthy physical development. Tests of three- to nine-year-old children in four communities around the world yielded evidence concerning block-building skills, memory, and the discernment of embedded figures. Naturalistic observations of these children were also undertaken in everyday settings. Open-fire cooking (as opposed to cooking on kerosene stoves) was associated with both lower cognitive performance and less frequent structured play at all ages. Although these correlational results do not reveal causal mechanisms, they are consistent with ideas about negative developmental consequences of exposure to open-fire cooking and suggest that research is needed on the effect on brain development of practices involving production of indoor smoke.

  11. Heater for Combustible-Gas Tanks

    NASA Technical Reports Server (NTRS)

    Ingle, Walter B.

    1987-01-01

    Proposed heater for pressurizing hydrogen, oxygen, or another combustible liquid or gas sealed in immersion cup in pressurized tank. Firmly supported in finned cup, coiled rod transfers heat through liquid metal to gas tank. Heater assembly welded or bolted to tank flange.

  12. Establishing conversation spaces in hastily formed networks: the worst fire in modern Swedish history.

    PubMed

    Lundberg, Jonas; Törnqvist, Eva K; Nadjm-Tehrani, Simin

    2014-10-01

    In presenting examples from the most extensive and demanding fire in modern Swedish history, this paper describes challenges facing hastily formed networks in exceptional situations. Two concepts that have been used in the analysis of the socio-technical systems that make up a response are conversation space and sensemaking. This paper argues that a framework designed to promote understanding of the sensemaking process must take into consideration the time and the location at which an individual is engaged in an event. In hastily formed networks, location is partly mediated through physical systems that form conversation spaces of players and their interaction practices. This paper identifies and discusses four challenges to the formation of shared conversation spaces. It is based on the case study of the 2006 Bodträskfors forest fire in Sweden and draws on the experiences of organised volunteers and firefighters who participated in a hastily formed network created to combat the fire. © 2014 The Author(s). Disasters © Overseas Development Institute, 2014.

  13. Tuberculosis and indoor biomass and kerosene use in Nepal: a case-control study.

    PubMed

    Pokhrel, Amod K; Bates, Michael N; Verma, Sharat C; Joshi, Hari S; Sreeramareddy, Chandrashekhar T; Smith, Kirk R

    2010-04-01

    In Nepal, tuberculosis (TB) is a major problem. Worldwide, six previous epidemiologic studies have investigated whether indoor cooking with biomass fuel such as wood or agricultural wastes is associated with TB with inconsistent results. Using detailed information on potential confounders, we investigated the associations between TB and the use of biomass and kerosene fuels. A hospital-based case-control study was conducted in Pokhara, Nepal. Cases (n = 125) were women, 20-65 years old, with a confirmed diagnosis of TB. Age-matched controls (n = 250) were female patients without TB. Detailed exposure histories were collected with a standardized questionnaire. Compared with using a clean-burning fuel stove (liquefied petroleum gas, biogas), the adjusted odds ratio (OR) for using a biomass-fuel stove was 1.21 [95% confidence interval (CI), 0.48-3.05], whereas use of a kerosene-fuel stove had an OR of 3.36 (95% CI, 1.01-11.22). The OR for use of biomass fuel for heating was 3.45 (95% CI, 1.44-8.27) and for use of kerosene lamps for lighting was 9.43 (95% CI, 1.45-61.32). This study provides evidence that the use of indoor biomass fuel, particularly as a source of heating, is associated with TB in women. It also provides the first evidence that using kerosene stoves and wick lamps is associated with TB. These associations require confirmation in other studies. If using kerosene lamps is a risk factor for TB, it would provide strong justification for promoting clean lighting sources, such as solar lamps.

  14. Hot-Fire Test Results of Liquid Oxygen/RP-2 Multi-Element Oxidizer-Rich Preburners

    NASA Technical Reports Server (NTRS)

    Protz, C. S.; Garcia, C. P.; Casiano, M. J.; Parton, J. A.; Hulka, J. R.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. To supply the oxidizer-rich combustion products to the main injector of the integrated test article, existing subscale preburner injectors from a previous NASA-funded oxidizer-rich staged combustion engine development program were utilized. For the integrated test article, existing and newly designed and fabricated inter-connecting hot gas duct hardware were used to supply the oxidizer-rich combustion products to the oxidizer circuit of the main injector of the thrust chamber. However, before one of the preburners was used in the integrated test article, it was first hot-fire tested at length to prove it could provide the hot exhaust gas mean temperature, thermal uniformity and combustion stability necessary to perform in the integrated test article experiment. This paper presents results from hot-fire testing of several preburner injectors in a representative combustion chamber with a sonic throat. Hydraulic, combustion performance, exhaust gas thermal uniformity, and combustion stability data are presented. Results from combustion stability modeling of these test results are described in a companion paper at this JANNAF conference, while hot-fire test results of the preburner injector in the integrated test article are described in another companion paper.

  15. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  16. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  17. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  18. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  19. Wavelength-dependent excess permittivity as indicator of kerosene in diesel oil.

    PubMed

    Kanyathare, Boniphace; Peiponen, Kai-Erik

    2018-04-20

    Adulteration of diesel oil by kerosene is a serious problem because of air pollution resulting from car exhaust gases. The objective of this study was to develop a relatively simple optical measurement and data analysis method to screen low-adulterated diesel oils. For this purpose, we introduce the utilization of refractive index measurement with a refractometer, scanning of visible-near-infrared transmittance, transmittance data inversion using the singly subtractive Kramers-Kronig relation, and exploitation of so-called wavelength-dependent relative excess permittivity. It is shown for three different diesel oil grades, adulterated with kerosene, that the excess permittivity is a powerful measure for screening fake diesel oils. The excess relative permittivity of such binary mixtures also reveals hidden spectral fingerprints that are neither visible in dispersion data alone nor in spectral transmittance measurements alone. We believe that the excess permittivity data are useful in the case of screening adulteration of diesel oil by kerosene and can further be explored for practical sensing solutions, e.g., in quality inspection of diesel oils in refineries.

  20. Evaluation of Candidate Materials for a High-Temperature Stirling Convertor Heater Head

    NASA Technical Reports Server (NTRS)

    Bowman, Randy; Ritzert, Frank; Freedman, Marc

    2003-01-01

    The Department of Energy (DOE) and NASA have identified Stirling Radioisotope Generators (SRG) as a candidate power system for use on long-duration, deep-space science missions and Mars rovers. One of the developments planned for an upgraded version of the current SRG design is to achieve higher efficiency by increasing the overall operating temperature of the system. Currently, the SRG operates with a heater head temperature of 650 C and is fabricated from the nickel base superalloy 718. This temperature is at the limit of Alloy 718's capability, and any planned increase in temperature will be contingent on identifying a more capable material from which to fabricate the heater head. To this end, an assessment of material candidates was performed assuming a range of heater head temperatures. The chosen alternative material candidates will be discussed, along with the development efforts needed to ensure that these materials can meet the demanding system requirements of long-duration operation in hostile environments.

  1. 49 CFR 179.12 - Interior heater systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Design Requirements § 179.12 Interior heater systems. (a) Interior heater systems shall be of approved design and materials. If a tank is divided into compartments, a separate system shall be provided for... 49 Transportation 2 2010-10-01 2010-10-01 false Interior heater systems. 179.12 Section 179.12...

  2. Temperature limited heaters using phase transformation of ferromagnetic material

    DOEpatents

    Vitek, John Michael [Oak Ridge, TN; Brady, Michael Patrick [Oak Ridge, TN

    2009-10-06

    Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.

  3. Slat Heater Boxes for Thermal Vacuum Testing

    NASA Technical Reports Server (NTRS)

    Ungar, Eugene

    2003-01-01

    Slat heater boxes have been invented for controlling the sink temperatures of objects under test in a thermal vacuum chamber, the walls of which are cooled to the temperature of liquid nitrogen. A slat heater box (see Figure 1) includes a framework of struts that support electrically heated slats that are coated with a high-emissivity optically gray paint. The slats can be grouped together into heater zones for the purpose of maintaining an even temperature within each side. The sink temperature of an object under test is defined as the steady-state temperature of the object in the vacuum/ radiative environment during the absence of any internal heat source or sink. The slat heater box makes it possible to closely control the radiation environment to obtain a desired sink temperature. The slat heater box is placed inside the cold thermal vacuum chamber, and the object under test is placed inside (but not in contact with) the slat heater box. The slat heaters occupy about a third of the field of view from any point on the surface of the object under test, the remainder of the field of view being occupied by the cold chamber wall. Thus, the radiation environment is established by the combined effects of the slat heater box and the cold chamber wall. Given (1) the temperature of the chamber wall, (2) the fractions of the field of view occupied by the chamber wall and the slat heater box, and (3) the emissivities of the slats, chamber wall, and the surface of object under test, the slat temperature required to maintain a desired sink temperature can be calculated by solving the equations of gray-body radiation for the steady-state adiabatic case (equal absorption and emission by the object under test). Slat heater boxes offer an important advantage over the infrared lamps that have been previously used to obtain desired sink temperatures: In comparison with an infrared lamp, a slat heater box provides a greater degree of sink temperature uniformity for a test

  4. Adjusting alloy compositions for selected properties in temperature limited heaters

    DOEpatents

    Brady; Michael Patrick , Horton, Jr.; Joseph Arno , Vitek; John Michael

    2010-03-23

    Heaters for treating a subsurface formation are described herein. Such heaters can be obtained by using the systems and methods described herein. The heater includes a heater section including iron, cobalt, and carbon. The heater section has a Curie temperature less than a phase transformation temperature. The Curie temperature is at least 740.degree. C. The heater section provides, when time varying current is applied to the heater section, an electrical resistance.

  5. Bilateral Deep Peroneal Nerve Paralysis Following Kerosene Self-Injection into External Hemorrhoids

    PubMed Central

    Rostami, Khalil; Farzaneh, Esmaeil; Abolhassani, Hassan

    2010-01-01

    Along with conventional therapies, some abrogated traditional treatment had been used for hemorrhoids like local Kerosene injection especially for extremely irritated external hemorrhoids. We report a rare case of Kerosene self-injection into the hemorrhoid. Despite antibiotics therapy, extent debridement, and colostomy, the patient died after 24 hours because of heart attack. Moreover, we discuss here the case with contact or injection of hydrocarbon materials and early care action to decrease the extensions of injury and side effects. PMID:20936130

  6. A modernized high-pressure heater protection system for nuclear and thermal power stations

    NASA Astrophysics Data System (ADS)

    Svyatkin, F. A.; Trifonov, N. N.; Ukhanova, M. G.; Tren'kin, V. B.; Koltunov, V. A.; Borovkov, A. I.; Klyavin, O. I.

    2013-09-01

    Experience gained from operation of high-pressure heaters and their protection systems serving to exclude ingress of water into the turbine is analyzed. A formula for determining the time for which the high-pressure heater shell steam space is filled when a rupture of tubes in it occurs is analyzed, and conclusions regarding the high-pressure heater design most advisable from this point of view are drawn. A typical structure of protection from increase of water level in the shell of high-pressure heaters used in domestically produced turbines for thermal and nuclear power stations is described, and examples illustrating this structure are given. Shortcomings of components used in the existing protection systems that may lead to an accident at the power station are considered. A modernized protection system intended to exclude the above-mentioned shortcomings was developed at the NPO Central Boiler-Turbine Institute and ZioMAR Engineering Company, and the design solutions used in this system are described. A mathematical model of the protection system's main elements (the admission and check valves) has been developed with participation of specialists from the St. Petersburg Polytechnic University, and a numerical investigation of these elements is carried out. The design version of surge tanks developed by specialists of the Central Boiler-Turbine Institute for excluding false operation of the high-pressure heater protection system is proposed.

  7. 10 CFR 429.17 - Residential water heaters.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Residential water heaters. 429.17 Section 429.17 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.17 Residential water heaters. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to residential water heaters...

  8. 10 CFR 429.17 - Residential water heaters.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Residential water heaters. 429.17 Section 429.17 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.17 Residential water heaters. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to residential water heaters...

  9. Herbert Easterly auxiliary truck heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The objective of this work was to continue the development of the Herbert Easterly heater apparatus for vehicles, such as semi-trailer tractors in order to fully establish its technical feasibility and provide the basis for its commercialization. This heater is auxiliary to the vehicle's primary heating system. With the engine off it heats both the vehicle engine to a temperature at which it starts easily and the vehicle passenger compartment. Specifically, this heater is automatically ignitable, operates directly from the vehicle diesel fuel supply and preheats the vehicle engine fuel prior to combustion. During the course of this work ninemore » different versions of prototype heaters were designed, constructed and tested. All designs were based on the ideas and principles outlined in the Easterly patent. Each successive version incorporated design and fabrication improvements relative to the previous version. The final version, Prototype 9, utilized a multiple water jacket design to capture additional heat from the combustion gases prior to exhausting to the atmosphere. This final prototype exceeded the performance of a commercially available Webasto DBW-2010 using the same commercial burner as the one used in the Webasto unit. The time required to raise the heater fluid temperature by 120{degree}F was 23% less (20 minutes compared to 26 minutes) for Prototype 9 compared to the commercially available unit. In addition a prototype heat exchanger for preheating engine fuel was designed, fabricated and tested. It was also determined that the Prototype 9 auxiliary heater could operate at 85{degree}F for approximately 6 hours on a fully charged 12 volt marine battery rated to deliver 500 cold cranking amps.« less

  10. Partially premixed prevalorized kerosene spray combustion in turbulent flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chrigui, M.; Ahmadi, W.; Sadiki, A.

    2010-04-15

    A detailed numerical simulation of kerosene spray combustion was carried out on a partially premixed, prevaporized, three-dimensional configuration. The focus was on the flame temperature profile dependency on the length of the pre-vaporization zone. The results were analyzed and compared to experimental data. A fundamental study was performed to observe the temperature variation and flame flashback. Changes were made to the droplet diameter, kerosene flammability limits, a combustion model parameter and the location of the combustion initialization. Investigations were performed for atmospheric pressure, inlet air temperature of 90 C and a global equivalence ratio of 0.7. The simulations were carriedmore » out using the Eulerian Lagrangian procedure under a fully two-way coupling. The Bray-Moss-Libby model was adjusted to account for the partially premixed combustion. (author)« less

  11. Effects of spray angle variation on mixing in a cold supersonic combustor with kerosene fuel

    NASA Astrophysics Data System (ADS)

    Zhu, Lin; Luo, Feng; Qi, Yin-Yin; Wei, Min; Ge, Jia-Ru; Liu, Wei-Lai; Li, Guo-Li; Jen, Tien-Chien

    2018-03-01

    Effective fuel injection and mixing is of particular importance for scramjet engines to be operated reliably because the fuel must be injected into high-speed crossflow and mixed with the supersonic air at an extremely short time-scale. This study numerically characterizes an injection jet under different spray angles in a cold kerosene-fueled supersonic flow and thus assesses the effects of the spray angle on the mixing between incident shock wave and transverse cavity injection. A detailed computational fluid dynamics model is developed in accordance with the real scramjet combustor. Next, the spray angles are designated as 45°, 90°, and 135° respectively with the other constant operational conditions (such as the injection diameter, velocity and pressure). Next, a combination of a three dimensional Couple Level Set & Volume of Fluids with an improved Kelvin-Helmholtz & Rayleigh-Taylor model is used to investigate the interaction between kerosene and supersonic air. The numerical predictions are focused on penetration depth, span expansion area, angle of shock wave and sauter mean diameter distribution of the kerosene droplets with or without evaporation. Finally, validation has been implemented by comparing the calculated to the measured in literature with good qualitative agreement. Results show that no matter whether the evaporation is considered, the penetration depth, span-wise angle and expansion area of the kerosene droplets are all increased with the spray angle, and most especially, that the size of the kerosene droplets is surely reduced with the spray angle increase. These calculations are beneficial to better understand the underlying atomization mechanism in the cold kerosene-fueled supersonic flow and hence provide insights into scramjet design improvement.

  12. Degradation and Characterization of Antimisting Kerosene (AMK).

    DTIC Science & Technology

    1982-12-01

    EXECUTIVE SUMMARY ................................................... I. INTRODUCTION ............................................... 2 II. DEGRADER...P - density Pll-P22 - normal stress difference P12 - shear stress x EXECUTIVE SI-9ARY CSingle pass degradation of Antinmisting Kerosene (ANIK) has...While the jet thrust experiment is more difficult to execute and interpret than flow experiments, a quality control test based on normal stresses would

  13. Solar Water-Heater Design Package

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Information on a solar domestic-hot water heater is contained in 146 page design package. System consists of solar collector, storage tanks, automatic control circuitry and auxiliary heater. Data-acquisition equipment at sites monitors day-by-day performance. Includes performance specifications, schematics, solar-collector drawings and drawings of control parts.

  14. Tuberculosis and Indoor Biomass and Kerosene Use in Nepal: A Case–Control Study

    PubMed Central

    Pokhrel, Amod K.; Bates, Michael N.; Verma, Sharat C.; Joshi, Hari S.; Sreeramareddy, Chandrashekhar T.; Smith, Kirk R.

    2010-01-01

    Background In Nepal, tuberculosis (TB) is a major problem. Worldwide, six previous epidemiologic studies have investigated whether indoor cooking with biomass fuel such as wood or agricultural wastes is associated with TB with inconsistent results. Objectives Using detailed information on potential confounders, we investigated the associations between TB and the use of biomass and kerosene fuels. Methods A hospital-based case–control study was conducted in Pokhara, Nepal. Cases (n = 125) were women, 20–65 years old, with a confirmed diagnosis of TB. Age-matched controls (n = 250) were female patients without TB. Detailed exposure histories were collected with a standardized questionnaire. Results Compared with using a clean-burning fuel stove (liquefied petroleum gas, biogas), the adjusted odds ratio (OR) for using a biomass-fuel stove was 1.21 [95% confidence interval (CI), 0.48–3.05], whereas use of a kerosene-fuel stove had an OR of 3.36 (95% CI, 1.01–11.22). The OR for use of biomass fuel for heating was 3.45 (95% CI, 1.44–8.27) and for use of kerosene lamps for lighting was 9.43 (95% CI, 1.45–61.32). Conclusions This study provides evidence that the use of indoor biomass fuel, particularly as a source of heating, is associated with TB in women. It also provides the first evidence that using kerosene stoves and wick lamps is associated with TB. These associations require confirmation in other studies. If using kerosene lamps is a risk factor for TB, it would provide strong justification for promoting clean lighting sources, such as solar lamps. PMID:20368124

  15. A 13-week dermal repeat-dose neurotoxicity study of hydrodesulfurized kerosene in rats.

    PubMed

    Breglia, Rudolph; Bui, Quang; Burnett, Donald; Koschier, Francis; Lapadula, Elizabeth; Podhasky, Paula; Schreiner, Ceinwen; White, Russell

    2014-01-01

    A 13-week dermal repeat-dose toxicity study was conducted with hydrodesulfurized (HDS) kerosene, a test material that also met the commercial specifications for aviation turbine fuel (jet A). The objectives were to assess the potential for target organ toxicity and neurotoxicity. The HDS kerosene was applied to the shaved backs of Sprague-Dawley CD rats, 12/sex/group, 6 h/d, 5 d/wk in doses of 0 (vehicle control), 165 mg/kg (20% HDS kerosene), 330 mg/kg (40% HDS kerosene), or 495 mg/kg (60% HDS kerosene). Additional rats (12/sex) from the control and the high-dose groups were held without treatment for 4 weeks to assess recovery. Standard parameters of toxicity were investigated during the in-life phase. At necropsy, organs were weighed and selected tissues were processed for microscopic evaluation. Neurobehavioral evaluations included tests of motor activity and functional observations that were conducted pretest, at intervals during the exposure period and after recovery. No test substance-related effects on mortality, clinical observations (except dermal irritation), body weight, or clinical chemistry values were observed. A dose-related increase in skin irritation, confirmed histologically as minimal, was evident at the dosing site. The only statistically significant change considered potentially treatment related was an increase in the neutrophil count in females at 13 weeks. No test article-related effects were observed in the neurobehavioral assessments or gross or microscopic findings in the peripheral or central nervous system tissues in any of the dose groups. Excluding skin irritation, the no observed adverse effect level value for all effects was considered 495 mg/kg/d.

  16. Severe lactic acidosis and acute renal failure following ingestion of metformin and kerosene oil: a case report.

    PubMed

    Rathnapala, Amila; Matthias, Thushara; Jayasinghe, Saroj

    2012-01-17

    Kerosene is a freely accessible hydrocarbon used in Sri Lankan (and other Asian) households for cooking and for lighting lamps. Kerosene poisoning is rarely reported among adults and its toxicological effects are not well known. Metformin is a commonly used oral hypoglycemic drug and its overdose leads primarily to lactic acidosis. Combined poisoning of metformin and kerosene and their interactions have not been reported. An 18-year-old, previously healthy, unmarried Sinhalese woman was referred following ingestion of 17.5 g of metformin and approximately 200 mL of kerosene oil in a suicide attempt. She had vomiting, burning epigastric pain, and a hypoglycemic seizure (capillary blood glucose of 42 mg/dL). Subsequently, she developed severe lactic acidosis followed by acute renal insufficiency, was treated with sodium bicarbonate, and underwent intermittent hemodialysis with bicarbonate. She recovered completely. This report proposes possible interactions that occur between metformin and kerosene that augment toxicity when the two are ingested together. It also stresses the importance of early treatment with intermittent hemodialysis in severe lactic acidosis with maintenance of blood glucose.

  17. Understanding the Residential Wood Heater Rules

    EPA Pesticide Factsheets

    Information on the components of the current wood heater new source performance standards (NSPS) and proposed updates to the NSPS including which types of heaters are covered under the rules and the benefits.

  18. Space Heaters, Computers, Cell Phone Chargers: How Plugged In AreCommercial Buildings?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez, Marla; Webber, Carrie; Brown, Richard

    2007-02-28

    Evidenceof electric plug loads in commercial buildings isvisible everyday: space heaters, portable fans, and the IT technician'stwo monitors connected to one PC. The Energy Information Administrationestimates that office and miscellaneous equipment together will consume2.18 quads in 2006, nearly 50 percent of U.S. commercial electricity use.Although the importance of commercial plug loads is documented, its verynature (diverse product types, products not installed when buildinginitially constructed, and products often hidden in closets) makes itdifficult to accurately count and categorize the end use.We auditedsixteen buildings in three cities (San Francisco, Atlanta, Pittsburgh)including office, medical and education building types. We inventoriedthe number and typesmore » of office and miscellaneous electric equipment aswell as estimated total energy consumption due to these product types. Intotal, we audited approximately 4,000 units of office equipment and 6,000units of miscellaneous equipment and covered a diverse range of productsranging from electric pencil sharpeners with a unit energy consumption(UEC) of 1 kWh/yr to a kiln with a UEC of 7,000 kWh/yr. Our paperpresents a summary of the density and type of plug load equipment foundas well as the estimated total energy consumption of the equipment.Additionally, we present equipment trends observed and provide insightsto how policy makers can target energy efficiency for this growing enduse.« less

  19. A Large Underestimate of Formic Acid from Tropical Fires: Constraints from Space-Borne Measurements.

    PubMed

    Chaliyakunnel, S; Millet, D B; Wells, K C; Cady-Pereira, K E; Shephard, M W

    2016-06-07

    Formic acid (HCOOH) is one of the most abundant carboxylic acids and a dominant source of atmospheric acidity. Recent work indicates a major gap in the HCOOH budget, with atmospheric concentrations much larger than expected from known sources. Here, we employ recent space-based observations from the Tropospheric Emission Spectrometer with the GEOS-Chem atmospheric model to better quantify the HCOOH source from biomass burning, and assess whether fire emissions can help close the large budget gap for this species. The space-based data reveal a severe model HCOOH underestimate most prominent over tropical burning regions, suggesting a major missing source of organic acids from fires. We develop an approach for inferring the fractional fire contribution to ambient HCOOH and find, based on measurements over Africa, that pyrogenic HCOOH:CO enhancement ratios are much higher than expected from direct emissions alone, revealing substantial secondary organic acid production in fire plumes. Current models strongly underestimate (by 10 ± 5 times) the total primary and secondary HCOOH source from African fires. If a 10-fold bias were to extend to fires in other regions, biomass burning could produce 14 Tg/a of HCOOH in the tropics or 16 Tg/a worldwide. However, even such an increase would only represent 15-20% of the total required HCOOH source, implying the existence of other larger missing sources.

  20. Study on separation of minor actinides from HLLW with new extractant of TODGA-DHOA/Kerosene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ye, Guo-an; Zhu, Wen-bin; Li, Feng-feng

    2013-07-01

    The extraction behavior of U, Np, Pu, Am, rare earth elements and Sr from nitric acid solutions by TODGA/dodecan, DHOA/dodecane and TODGA-DHOA/dodecane were investigated, respectively. Based on experimental results, a separation process was proposed for minor actinide isolation from high level liquid waste (HLLW): the TODGA-DHOA/kerosene system. The multi-stage counter-current cascade experiments were carried out for the purpose by 0.1 mol/l TODGA-1.0 mol/l DHOA/kerosene with miniature mixer- settler contactor rigs (8 stages for extraction, 6 stages for scrubbing, 8 stages for first stripping, 8 stages for second stripping). The results show that the recovery efficiencies of the actinides and lanthanidesmore » are more than 99.9%, whereas less than 1% Sr was extracted by 0.1 mol/l TODGA - 1.0 mol/l DHOA/kerosene. The stripping efficiencies of U, Np and Pu are more than 95% in the first stripping step by 0.5 mol/l HNO{sub 3} + 0.5 mol/l AHA(aceto-hydroxamic acid), all of the remained actinides and lanthanides can be stripped by 0.01 mol/l HNO{sub 3} in the second stripping step. 99% Sr was extracted by 0.1 mol/l TODGA/kerosene, so Sr can be recovered efficiently directly from the raffinate by 0.1 mol/l TODGA/kerosene. (authors)« less

  1. Implementation of a self-controlling heater

    NASA Technical Reports Server (NTRS)

    Strange, M. G.

    1973-01-01

    Temperature control of radiation sensors, targets, and other critical components is a common requirement in modern scientific instruments. Conventional control systems use a heater and a temperature sensor mounted on the body to be controlled. For proportional control, the sensor provides feedback to circuitry which drives the heater with an amount of power proportional to the temperature error. It is impractical or undesirable to mount both a heater and a sensor on certain components such as ultra-small parts or thin filaments. In principle, a variable current through the element is used for heating, and the change in voltage drop due to the element's temperature coefficient is separated and used to monitor or control its own temperature. Since there are no thermal propagation delays between heater and sensor, such control systems are exceptionally stable.

  2. Prevalence of hydrogen cyanide and carboxyhaemoglobin in victims of smoke inhalation during enclosed-space fires: a combined toxicological risk.

    PubMed

    Grabowska, Teresa; Skowronek, Rafał; Nowicka, Joanna; Sybirska, Halina

    2012-09-01

    Hydrogen cyanide (HCN) is one of the most toxic components of fire smoke, but insufficient attention is paid to its potential role as a cause of injury or death in victims (alive or dead) of enclosed-space fires. To analyse the prevalence of toxic HCN exposure in fire victims and factors that may influence its toxicity, particularly the co-presence of carbon monoxide (CO) and ethanol. Blood samples from fire victims and persons rescued from fires were analysed. A positive result for HCN (mean concentration 16.83 mg/l) was detected in blood samples from 169 of 285 fire-related deaths (59%). Ethanol was present in 91 (65%) of 139 samples with coincident presence of HCN and carboxyhaemoglobin (COHb). HCN (mean 4.0 mg/l) was also detected in 20 of 40 (50%) fire survivors. The high prevalence of coincident CO and HCN in enclosed-space, fire-related deaths should alert clinicians to suspect toxic HCN exposure in all persons rescued from fire with signs and symptoms of respiratory distress. Medical procedures in persons rescued from enclosed-space fires, especially in the pre-hospital setting, should be augmented to cover the possibility of toxic HCN exposure, particularly in individuals who do not respond to standard supportive therapy. Likewise, post-mortem investigations should routinely include assays for HCN when determining probable cause of death.

  3. Energy Factor Analysis for Gas Heat Pump Water Heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gluesenkamp, Kyle R

    2016-01-01

    Gas heat pump water heaters (HPWHs) can improve water heating efficiency with zero GWP and zero ODP working fluids. The energy factor (EF) of a gas HPWH is sensitive to several factors. In this work, expressions are derived for EF of gas HPWHs, as a function of heat pump cycle COP, tank heat losses, burner efficiency, electrical draw, and effectiveness of supplemental heat exchangers. The expressions are used to investigate the sensitivity of EF to each parameter. EF is evaluated on a site energy basis (as used by the US DOE for rating water heater EF), and a primary energy-basismore » energy factor (PEF) is also defined and included. Typical ranges of values for the six parameters are given. For gas HPWHs, using typical ranges for component performance, EF will be 59 80% of the heat pump cycle thermal COP (for example, a COP of 1.60 may result in an EF of 0.94 1.28). Most of the reduction in COP is due to burner efficiency and tank heat losses. Gas-fired HPWHs are theoretically be capable of an EF of up to 1.7 (PEF of 1.6); while an EF of 1.1 1.3 (PEF of 1.0 1.1) is expected from an early market entry.« less

  4. Extremophiles in Household Water Heaters

    NASA Astrophysics Data System (ADS)

    Wilpiszeski, R.; House, C. H.

    2016-12-01

    A significant fraction of Earth's microbial diversity comes from species living in extreme environments, but natural extreme environments can be difficult to access. Manmade systems like household water heaters serve as an effective proxy for thermophilic environments that are otherwise difficult to sample directly. As such, we are investigating the biogeography, taxonomic distribution, and evolution of thermophiles growing in domestic water heaters. Citizen scientists collected hot tap water culture- and filter- samples from 101 homes across the United States. We recovered a single species of thermophilic heterotroph from culture samples inoculated from water heaters across the United States, Thermus scotoductus. Whole-genome sequencing was conducted to better understand the distribution and evolution of this single species. We have also sequenced hyper-variable regions of the 16S rRNA gene from whole-community filter samples to identify the broad diversity and distribution of microbial cells captured from each water heater. These results shed light on the processes that shape thermophilic populations and genomes at a spatial resolution that is difficult to access in naturally occurring extreme ecosystems.

  5. Programmable Thermostats for MPLM Shell Heater Control ULF1. 1; Thermal Performances

    NASA Technical Reports Server (NTRS)

    Glasgow, Shaun; Clark, Dallas; Trichilo, Michele; Trichilo, Michele

    2007-01-01

    The Multi-Purpose Logistics Module (MPLM) is the primary carrier for "pressurized" logistics to and from the International Space Station (ISS). The MPLM is transported in the payload bay of the Space Shuttle and is docked to the ISS for unloading, and reloading, of contents within the ISS shirt sleeve environment. Foil heaters, controlled originally with bi-metallic thermostats, are distributed across the outside of the MPLM structure and are utilized to provide energy to the structure to avoid exposure to cold temperatures and prevent condensation. The existing bi-metallic, fixed temperature set point thermostats have been replaced with Programmable Thermostats Modules (PTMs) in the Passive Thermal Control Subsystem (PTCS) 28Vdc shell heater circuits. The goal of using the PTM thermostat is to improve operational efficiency of the MPLM on-orbit shell heaters by providing better shell temperature control via feedback control capability. Each heater circuit contains a programmable thermostat connected to an external temperature sensor, a Resistive Temperature Device (RTD), which is used to provide continuous temperature monitoring capability. Each thermostat has programmable temperature set points and control spans. The data acquisition system uses a standard RS-485 serial interface communications cable to provide digital control capability. The PTM system was designed by MSFC, relying upon ALTEC support for their integration within the MPLM system design, while KSC performed the installation and ground checkout testing of the thermostat and RS-485 communication cable on the MPLM FM1 flight module. The PTMs were used for the first time during the STS-121/ULF1.1 mission. This paper will describe the design, development and verification of the PTM system, as well as the PTM flight performance and comparisons with SINDA thermal model predictions.

  6. Performance Analysis and Parametric Study of a Natural Convection Solar Air Heater With In-built Oil Storage

    NASA Astrophysics Data System (ADS)

    Dhote, Yogesh; Thombre, Shashikant

    2016-10-01

    This paper presents the thermal performance of the proposed double flow natural convection solar air heater with in-built liquid (oil) sensible heat storage. Unused engine oil was used as thermal energy storage medium due to its good heat retaining capacity even at high temperatures without evaporation. The performance evaluation was carried out for a day of the month March for the climatic conditions of Nagpur (India). A self reliant computational model was developed using computational tool as C++. The program developed was self reliant and compute the performance parameters for any day of the year and would be used for major cities in India. The effect of change in storage oil quantity and the inclination (tilt angle) on the overall efficiency of the solar air heater was studied. The performance was tested initially at different storage oil quantities as 25, 50, 75 and 100 l for a plate spacing of 0.04 m with an inclination of 36o. It has been found that the solar air heater gives the best performance at a storage oil quantity of 50 l. The performance of the proposed solar air heater is further tested for various combinations of storage oil quantity (50, 75 and 100 l) and the inclination (0o, 15o, 30o, 45o, 60o, 75o, 90o). It has been found that the proposed solar air heater with in-built oil storage shows its best performance for the combination of 50 l storage oil quantity and 60o inclination. Finally the results of the parametric study was also presented in the form of graphs carried out for a fixed storage oil quantity of 25 l, plate spacing of 0.03 m and at an inclination of 36o to study the behaviour of various heat transfer and fluid flow parameters of the solar air heater.

  7. Assessment of radioisotope heaters for remote terrestrial applications

    NASA Astrophysics Data System (ADS)

    Uherka, Kenneth L.

    This paper examines the feasibility of using radioisotope byproducts for special heating applications at remote sites in Alaska and other cold regions. The investigation included assessment of candidate radioisotope materials for heater applications, identification of the most promising cold-region applications, evaluation of key technical issues and implementation constraints, and development of conceptual heater designs for candidate applications. Strontium-90 (Sr-90) was selected as the most viable fuel for radioisotopic heaters used in terrestrial applications. Opportunities for the application of radioisotopic heaters were determined through site visits to representative Alaskan installations. Candidate heater applications included water storage tanks, sludge digesters, sewage lagoons, water piping systems, well-head pumping stations, emergency shelters, and fuel storage tank deicers. Radio-isotopic heaters for freeze-up protection of water storage tanks and for enhancement of biological waste treatment processes at remote sites were selected as the most promising applications.

  8. Shipping device for heater unit assembly

    DOEpatents

    Blaushild, Ronald M.; Abbott, Stephan L.; Miller, Phillip E.; Shaffer, Robert

    1991-01-01

    A shipping device for a heater unit assembly (23), the heater unit assembly (23) including a cylindrical wall (25) and a top plate (31) secured to the cylindrical wall (25) and having a flange portion which projects radially beyond the outer surface of the cylindrical wall (25), and the shipping device including: a cylindrical container (3) having a closed bottom (13); a support member (47) secured to the container (3) and having an inwardly directed flange for supporting the flange portion of the top plate (31); a supplemental supporting system (1) for positioning the heater unit assembly (23) in the container (3) at a spaced relation from the inner surface and bottom wall (13) of the container (3); a cover (15) for closing the top of the container (3); and a container supporting structure (5,7,8) supporting the container (3) in a manner to permit the container (3) to be moved, relative to the supporting structure (5,7,8 ), between a vertical position for loading and unloading the assembly (23) and a horizontal position for transport of the assembly (23). A seal (57) is interposed between the container (3) and the cover (15) for sealing the interior of the container (3) from the environment. An abutment member (41) is mounted on the container supporting structure (5,7,8) for supporting the container bottom (13), when the container (3) is in the vertical position, to prevent the container (3) from moving past the vertical position in the direction away from the horizontal position, and a retainer member (55) is secured within the cover (15) for retaining the assembly top plate (31) in contact with the support member (47) when the cover (15) closes the top of the container (3).

  9. Explosives tester with heater

    DOEpatents

    Del Eckels, Joel [Livermore, CA; Nunes, Peter J [Danville, CA; Simpson, Randall L [Livermore, CA; Whipple, Richard E [Livermore, CA; Carter, J Chance [Livermore, CA; Reynolds, John G [San Ramon, CA

    2010-08-10

    An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.

  10. Increased risk of respiratory illness associated with kerosene fuel use among women and children in urban Bangalore, India.

    PubMed

    Choi, Jae-Young; Baumgartner, Jill; Harnden, Sarah; Alexander, Bruce H; Town, Robert J; D'Souza, George; Ramachandran, Gurumurthy

    2015-02-01

    Kerosene is a widely used cooking and lighting fuel in developing countries. The potential respiratory health effects of cooking with kerosene relative to cooking with cleaner fuels such as liquefied petroleum gas (LPG) have not been well characterised. We sampled 600 households from six urban neighbourhoods in Bangalore, India. Each household's primary cook, usually the woman of the house, was interviewed to collect information on current domestic fuel use and whether there was any presence of respiratory symptoms or illness in her or in the children in the household. Our analysis was limited to 547 adult females (ages 18-85) and 845 children (ages 0-17) in households exclusively cooking with either kerosene or LPG. We investigated the associations between kerosene use and the likelihood of having respiratory symptoms or illness using multivariate logistic regression models. Among adult women, cooking with kerosene was associated with cough (OR=1.88; 95% CI 1.19 to 2.99), bronchitis (OR=1.54; 95% CI 1.00 to 2.37), phlegm (OR=1.51; 95% CI 0.98 to 2.33) and chest illness (OR=1.61; 95% CI 1.02 to 2.53), relative to cooking with LPG in the multivariate models. Among children, living in a household cooking with kerosene was associated with bronchitis (OR=1.91; 95% CI 1.17 to 3.13), phlegm (OR=2.020; 95% CI 1.29 to 3.74) and chest illness (OR=1.70; 95% CI 0.99 to 2.90) after adjusting for other covariates. We also found associations between kerosene use and wheezing, difficulty breathing and asthma in adults and cough and wheezing in children, though these associations were not statistically significant. Women and children in households cooking with kerosene were more likely to have respiratory symptoms and illnesses compared with those in households cooking with LPG. Transitioning from kerosene to LPG for cooking may improve respiratory health among adult women and children in this population. Published by the BMJ Publishing Group Limited. For permission to use (where

  11. Resolving vorticity-driven lateral fire spread using the WRF-Fire coupled atmosphere-fire numerical model

    NASA Astrophysics Data System (ADS)

    Simpson, C. C.; Sharples, J. J.; Evans, J. P.

    2014-09-01

    Vorticity-driven lateral fire spread (VLS) is a form of dynamic fire behaviour, during which a wildland fire spreads rapidly across a steep leeward slope in a direction approximately transverse to the background winds. VLS is often accompanied by a downwind extension of the active flaming region and intense pyro-convection. In this study, the WRF-Fire (WRF stands for Weather Research and Forecasting) coupled atmosphere-fire model is used to examine the sensitivity of resolving VLS to both the horizontal and vertical grid spacing, and the fire-to-atmosphere coupling from within the model framework. The atmospheric horizontal and vertical grid spacing are varied between 25 and 90 m, and the fire-to-atmosphere coupling is either enabled or disabled. At high spatial resolutions, the inclusion of fire-to-atmosphere coupling increases the upslope and lateral rate of spread by factors of up to 2.7 and 9.5, respectively. This increase in the upslope and lateral rate of spread diminishes at coarser spatial resolutions, and VLS is not modelled for a horizontal and vertical grid spacing of 90 m. The lateral fire spread is driven by fire whirls formed due to an interaction between the background winds and the vertical circulation generated at the flank of the fire front as part of the pyro-convective updraft. The laterally advancing fire fronts become the dominant contributors to the extreme pyro-convection. The results presented in this study demonstrate that both high spatial resolution and two-way atmosphere-fire coupling are required to model VLS with WRF-Fire.

  12. Space-time clustering analysis of wildfires: The influence of dataset characteristics, fire prevention policy decisions, weather and climate.

    PubMed

    Parente, Joana; Pereira, Mário G; Tonini, Marj

    2016-07-15

    The present study focuses on the dependence of the space-time permutation scan statistics (STPSS) (1) on the input database's characteristics and (2) on the use of this methodology to assess changes on the fire regime due to different type of climate and fire management activities. Based on the very strong relationship between weather and the fire incidence in Portugal, the detected clusters will be interpreted in terms of the atmospheric conditions. Apart from being the country most affected by the fires in the European context, Portugal meets all the conditions required to carry out this study, namely: (i) two long and comprehensive official datasets, i.e. the Portuguese Rural Fire Database (PRFD) and the National Mapping Burnt Areas (NMBA), respectively based on ground and satellite measurements; (ii) the two types of climate (Csb in the north and Csa in the south) that characterizes the Mediterranean basin regions most affected by the fires also divide the mainland Portuguese area; and, (iii) the national plan for the defence of forest against fires was approved a decade ago and it is now reasonable to assess its impacts. Results confirmed (1) the influence of the dataset's characteristics on the detected clusters, (2) the existence of two different fire regimes in the country promoted by the different types of climate, (3) the positive impacts of the fire prevention policy decisions and (4) the ability of the STPSS to correctly identify clusters, regarding their number, location, and space-time size in spite of eventual space and/or time splits of the datasets. Finally, the role of the weather on days when clustered fires were active was confirmed for the classes of small, medium and large fires. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Candidate Materials Evaluated for a High-Temperature Stirling Convertor Heater Head

    NASA Technical Reports Server (NTRS)

    Bowman, Randy R.; Ritzert, Frank J.

    2005-01-01

    The Department of Energy and NASA have identified Stirling Radioisotope Generators (SRGs) as a candidate power system for use on long-duration, deep-space science missions and Mars rovers. One of the developments planned for an upgraded version of the current SRG design is to achieve higher efficiency by increasing the overall operating temperature of the system. Currently, the SRG operates with a heater head temperature of 650 C and is fabricated from the nickel-base superalloy 718. The current operating temperature is at the limit of alloy 718 s capability, and any planned increase in temperature will be contingent on identifying a more capable material from which to fabricate the heater head. To this end, personnel at the NASA Glenn Research Center are evaluating advanced materials for a high-temperature heater head to allow a higher convertor temperature ratio and, thus, increase the system efficiency. A generic list of properties that were used to screen the candidate materials follows: (1) creep, (2) fabricability, (3) helium gas containment, (4) long-term stability and compatibility, (5) ability to form a hermetical closeout seal, and (6) ductility and toughness.

  14. Particulate matter sensor with a heater

    DOEpatents

    Hall, Matthew [Austin, TX

    2011-08-16

    An apparatus to detect particulate matter. The apparatus includes a sensor electrode, a shroud, and a heater. The electrode measures a chemical composition within an exhaust stream. The shroud surrounds at least a portion of the sensor electrode, exclusive of a distal end of the sensor electrode exposed to the exhaust stream. The shroud defines an air gap between the sensor electrode and the shroud and an opening toward the distal end of the sensor electrode. The heater is mounted relative to the sensor electrode. The heater burns off particulate matter in the air gap between the sensor electrode and the shroud.

  15. Three-Dimensional Printable High-Temperature and High-Rate Heaters.

    PubMed

    Yao, Yonggang; Fu, Kun Kelvin; Yan, Chaoyi; Dai, Jiaqi; Chen, Yanan; Wang, Yibo; Zhang, Bilun; Hitz, Emily; Hu, Liangbing

    2016-05-24

    High temperature heaters are ubiquitously used in materials synthesis and device processing. In this work, we developed three-dimensional (3D) printed reduced graphene oxide (RGO)-based heaters to function as high-performance thermal supply with high temperature and ultrafast heating rate. Compared with other heating sources, such as furnace, laser, and infrared radiation, the 3D printed heaters demonstrated in this work have the following distinct advantages: (1) the RGO based heater can operate at high temperature up to 3000 K because of using the high temperature-sustainable carbon material; (2) the heater temperature can be ramped up and down with extremely fast rates, up to ∼20 000 K/second; (3) heaters with different shapes can be directly printed with small sizes and onto different substrates to enable heating anywhere. The 3D printable RGO heaters can be applied to a wide range of nanomanufacturing when precise temperature control in time, placement, and the ramping rate are important.

  16. Thin, Light, Flexible Heaters Save Time and Energy

    NASA Technical Reports Server (NTRS)

    2007-01-01

    The Icing Branch at NASA's Glenn Research Center uses the Center's Icing Research Tunnel (IRT) and Icing Research Aircraft to research methods for evaluating and simulating the growth of ice on aircraft, the effects that ice may have on aircraft in flight, and the development and effectiveness of various ice protection and detection systems. EGC Enterprises Inc. (EGC), of Chardon, Ohio, used the IRT to develop thermoelectric thin-film heater technology to address in-flight icing on aircraft wings. Working with researchers at Glenn and the original equipment manufacturers of aircraft parts, the company tested various thin, flexible, durable, lightweight, and efficient heaters. Development yielded a thin-film heater technology that can be used in many applications in addition to being an effective deicer for aircraft. This new thermoelectric heater was dubbed the QoFoil Rapid Response Thin-Film Heater, or QoFoil, for short. The product meets all criteria for in-flight use and promises great advances in thin-film, rapid response heater technology for a broad range of industrial applications. Primary advantages include time savings, increased efficiency, and improved temperature uniformity. In addition to wing deicing, EGC has begun looking at the material's usefulness for applications including cooking griddles, small cabinet heaters, and several laboratory uses.

  17. Strategy Guideline. Proper Water Heater Selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Springer, D.; German, A.

    2015-04-09

    This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

  18. Strategy Guideline: Proper Water Heater Selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Springer, D.; German, A.

    2015-04-01

    This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

  19. Antimisting kerosene. [reduced flammability during aircraft accident circumstances

    NASA Technical Reports Server (NTRS)

    Schmidt, H. W.

    1980-01-01

    The antimisting additive ((FM-9) was tested in terms of its propulsion systems performance. The effect of the additive on engine operation was evaluated, operating problems were identified, the adaptability of engines to antimisting kerosene was assessed, and the potential viability of this fuel for use in present and future fan jet engines was determined.

  20. Soil pollution by petroleum products, III. Kerosene stability in soil columns as affected by volatilization

    NASA Astrophysics Data System (ADS)

    Galin, Ts.; Gerstl, Z.; Yaron, B.

    1990-05-01

    The stability of kerosene in soils as affected by volatization was determined in a laboratory column experiment by following the losses in the total concentration and the change in composition of the residuals in a dune sand, a loamy sand, and a silty loam soil during a 50-day period. Seven major compounds ranging between C 9 and C 15 were selected from a large variety of hydrocarbons forming kerosene and their presence in the remaining petroleum product was determined. The change in composition of kerosene during the experimental period was determined by gas chromatography and related to the seven major compounds selected. The experimental conditions — air-dairy soil and no subsequent addition of water—excluded both biodegradative and leaching. losses. The losses of kerosene in air-dried soil columns during the 50-day experimental period and the changes in the composition of the remaining residues due to volatilization are reported. The volatilization of all the components determined was greater from the dune sand and loamy sand soils than from the silty loam soil. It was assumed that the reason for this behavior was that the dune sand and the loamy sand soils contain a greater proportion of large pores (>4.5 μm) than the silty loam soil, even though the total porosity of the loamy sand and the silty loam is similar. In all the soils in the experiment, the components with a high carbon number formed the main fraction of the kerosene residues after 50 days of incubation.

  1. Structure analysis and size distribution of particulate matter from candles and kerosene combustion in burning chamber

    NASA Astrophysics Data System (ADS)

    Baitimirova, M.; Osite, A.; Katkevics, J.; Viksna, A.

    2012-08-01

    Burning of candles generates particulate matter of fine dimensions that produces poor indoor air quality, so it may cause harmful impact on human health. In this study solid aerosol particles of burning of candles of different composition and kerosene combustion were collected in a closed laboratory system. Present work describes particulate matter collection for structure analysis and the relationship between source and size distribution of particulate matter. The formation mechanism of particulate matter and their tendency to agglomerate also are described. Particles obtained from kerosene combustion have normal size distribution. Whereas, particles generated from the burning of stearin candles have distribution shifted towards finer particle size range. If an additive of stearin to paraffin candle is used, particle size distribution is also observed in range of towards finer particles. A tendency to form agglomerates in a short time is observed in case of particles obtained from kerosene combustion, while in case of particles obtained from burning of candles of different composition such a tendency is not observed. Particles from candles and kerosene combustion are Aitken and accumulation mode particles

  2. [Determination of ru, rh and Pd in 30% trialkyl phosphine oxide (TRPO)-kerosene by inductively coupled plasma-atomic emission spectrum (ICP-AES)].

    PubMed

    Wang, Jian-Chen; Zhang, Lin

    2013-07-01

    The determination method of Ru, Rh and Pd in 30% TRPO-kerosene ICP-AES was studied by using aqueous calibration reference solution and choosing ethanol as diluent. The effects of the contents of 30% TRPO-kerosene and aqueous solution and the concentration of HNO3 in 30% TRPO-kerosene on the intensities of Ru, Rh and Pd were described. The optimized condition for preparing samples and calibration solutions was chosen as follows: The contents of 30% TRPO-kerosene and aqueous phase were 10% (V/V) and 5% (V/V) respectively and the concentration of HNO3 30% TRPO-kerosene was 0.20 mol x L(-1). The determination method of Au, Ru and Pd was set up according to the above condition. The detection limit, precision and recovery ratio of Ru, Rh and Pd are well. The method is not only used in determination of Au, Ru and Pd in 30% TRPO-kerosene, but also used in other organic phases.

  3. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... protection requirements for accommodation spaces and modules? 149.641 Section 149.641 Navigation and... the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation spaces and modules must be designed, located, and constructed so as to minimize the effects of flame...

  4. "Starfish" Heater Head For Stirling Engine

    NASA Technical Reports Server (NTRS)

    Vitale, N.

    1993-01-01

    Proposed "starfish" heater head for Stirling engine enables safe use of liquid sodium as heat-transfer fluid. Sodium makes direct contact with heater head but does not come in contact with any structural welds. Design concept minimizes number of, and simplifies nonstructural thermal welds and facilitates inspection of such welds.

  5. Transparent and Flexible Large-scale Graphene-based Heater

    NASA Astrophysics Data System (ADS)

    Kang, Junmo; Lee, Changgu; Kim, Young-Jin; Choi, Jae-Boong; Hong, Byung Hee

    2011-03-01

    We report the application of transparent and flexible heater with high optical transmittance and low sheet resistance using graphene films, showing outstanding thermal and electrical properties. The large-scale graphene films were grown on Cu foil by chemical vapor deposition methods, and transferred to transparent substrates by multiple stacking. The wet chemical doping process enhanced the electrical properties, showing a sheet resistance as low as 35 ohm/sq with 88.5 % transmittance. The temperature response usually depends on the dimension and the sheet resistance of the graphene-based heater. We show that a 4x4 cm2 heater can reach 80& circ; C within 40 seconds and large-scale (9x9 cm2) heater shows uniformly heating performance, which was measured using thermocouple and infra-red camera. These heaters would be very useful for defogging systems and smart windows.

  6. Simulation of a GOX-kerosene subscale rocket combustion chamber

    NASA Astrophysics Data System (ADS)

    Höglauer, Christoph; Kniesner, Björn; Knab, Oliver; Kirchberger, Christoph; Schlieben, Gregor; Kau, Hans-Peter

    2011-12-01

    In view of future film cooling tests at the Institute for Flight Propulsion (LFA) at Technische Universität München, the Astrium in-house spray combustion CFD tool Rocflam-II was validated against first test data gained from this rocket test bench without film cooling. The subscale rocket combustion chamber uses GOX and kerosene as propellants which are injected through a single double swirl element. Especially the modeling of the double swirl element and the measured wall roughness were adapted on the LFA hardware. Additionally, new liquid kerosene fluid properties were implemented and verified in Rocflam-II. Also the influences of soot deposition and hot gas radiation on the wall heat flux were analytically and numerically estimated. In context of reviewing the implemented evaporation model in Rocflam-II, the binary diffusion coefficient and its pressure dependency were analyzed. Finally simulations have been performed for different load points with Rocflam-II showing a good agreement compared to test data.

  7. Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Margle, Janice M. (Editor)

    1987-01-01

    Fire detection, fire standards and testing, fire extinguishment, inerting and atmospheres, fire-related medical science, aircraft fire safety, Space Station safety concerns, microgravity combustion, spacecraft material flammability testing, and metal combustion are among the topics considered.

  8. Effects of crude kerosene on testosterone levels, aggression and toxicity in rat.

    PubMed

    Njoroge, Rachel W; Macharia, Benson N; Sawe, Dinah J; Maiyoh, Geoffrey K

    2015-01-01

    The use of crude kerosene as a dietary supplement in boarding schools has been a common practice in east Africa and other countries for many years, with the belief of it reducing the sex drive (libido) at the pubertal stage. There is however no scientific basis for this belief. The present study aimed at using a rat animal model to investigate the effects of crude kerosene on serum testosterone levels, aggression and its possible toxic effects. Fifteen male albino rats of approximately similar age and average weights were put into three groups of five animals each; the control group (placebo), low kerosene dose (10 μl/day) group and high kerosene dose (300 μl/day) group. ELISA was used to determine the serum testosterone levels. During treatment, changes in aggression were observed and noted. Liver toxicity was determined using enzyme assays, total protein and albumin while renal toxicity was monitored using serum creatinine levels. A full hemogram was conducted to determine hematological effects. Various tissue biopsies were obtained and examined using histopathological techniques for evidence of toxicity. Contrary to the common belief, our findings showed an overall increase of serum testosterone levels of up to 66% in the low dose and 75% in the high dose groups, with an increasing trend by the end of the study. The high dose group showed significantly increased levels of white blood cells (WBC) ( p  = 0.036), red blood cells (RBC) ( p  = 0.025), hematocrit (HCT) ( p  = 0.03), red cell distribution width ( p  = 0.028) and platelets ( p  = 0.017). The histological results of the stomach indicated chronic gastritis.

  9. Electrochemical cell has internal resistive heater element

    NASA Technical Reports Server (NTRS)

    Colston, E. F.; Ford, F. E.; Hennigan, T. J.

    1968-01-01

    External source supplies power to electrochemical cells containing internal resistive heater element. Each cell plate is individually contained in its own Pellon bag, enabling the heater element to be arranged in a continuous, parallel circuit.

  10. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency watermore » heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  11. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  12. Investigations on the droplet distributions in the atomization of kerosene jets in supersonic crossflows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Liyin; Wang, Zhen-guo, E-mail: wangzhenguo-wzg@163.com; Li, Qinglian

    2015-09-07

    Phase Doppler anemometry was applied to investigate the atomization processes of a kerosene jet injected into Ma = 1.86 crossflow. Physical behaviors, such as breakup and coalescence, are reproduced through the analysis of the spatial distribution of kerosene droplets' size. It is concluded that Sauter mean diameter distribution shape transforms into “I” type from “C” type as the atomization development. Simultaneously, the breakup of large droplets and the coalescence of small droplets can be observed throughout the whole atomization process.

  13. Fire tests to evaluate the potential fire threat and its effects on HEPA filter integrity in cell ventilation at the Oak Ridge National Laboratory, Building 7920

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasegawa, H.K.; Staggs, K.J.; Doughty, S.M.

    1992-12-01

    As a result of a DOE (Tiger Team) Technical Safety Appraisal (November 1990) of the Radiochemical Engineering Development Center (REDC), ORNL Building 7920, a number of fire protection concerns were identified. The primary concern was the perceived loss of ventilation system containment due to the thermal destruction and/or breaching of the prefilters and/or high-efficiency particulate air filters (HEPA `s) and the resultant radioactive release to the external environment. The following report describes the results of an extensive fire test program performed by the Fire Research Discipline (FRD) of the Special Projects Division of Lawrence Livermore National Lab (LLNL) and fundedmore » by ORNL to address these concerns. Full scale mock-ups of a REDC hot cell tank pit, adjacent cubicle pit, and associated ventilation system were constructed at LLNL and 13 fire experiments were conducted to specifically answer the questions raised by the Tiger Team. Our primary test plan was to characterize the burning of a catastrophic solvent spill (kerosene) of 40 liters and its effect on the containment ventilation system prefilters and HEPA filters. In conjunction with ORNL and Lockwood Greene we developed a test matrix that assessed the fire performance of the prefilters and HEPA filters; evaluated the fire response of the fiber reinforced plastic (FRP) epoxy ventilation duct work; the response and effectiveness of the fire protection system, the effect of fire in a cubicle on the vessel off-gas (VOG) elbow, and other fire safety questions.« less

  14. The Value of Assessing Public Perceptions: Wildland Fire and Defensible Space

    ERIC Educational Resources Information Center

    Monroe, Martha C.; Nelson, Kristen C.

    2004-01-01

    Fire is a challenge in the wildland-urban interface. Although resource managers encourage residents to create defensible space, many do not. This study illustrates the value of using a needs assessment to better understand perceptions of an audience in order to develop meaningful messages and materials. In this case, our audience is residents of…

  15. Exposure reductions associated with introduction of solar lamps to kerosene lamp-using households in Busia County, Kenya.

    PubMed

    Lam, N L; Muhwezi, G; Isabirye, F; Harrison, K; Ruiz-Mercado, I; Amukoye, E; Mokaya, T; Wambua, M; Bates, M N

    2018-03-01

    Solar lamps are a clean and potentially cost-effective alternative to polluting kerosene lamps used by millions of families in developing countries. By how much solar lamps actually reduce exposure to pollutants, however, has not been examined. Twenty households using mainly kerosene for lighting were enrolled through a secondary school in Busia County, Kenya. Personal PM 2.5 and CO concentrations were measured on a school pupil and an adult in each household, before and after provision of 3 solar lamps. PM 2.5 concentrations were measured in main living areas, pupils' bedrooms, and kitchens. Usage sensors measured use of kerosene and solar lighting devices. Ninety percent of baseline kerosene lamp use was displaced at 1-month follow-up, corresponding to average PM 2.5 reductions of 61% and 79% in main living areas and pupils' bedrooms, respectively. Average 48-h exposure to PM 2.5 fell from 210 to 104 μg/m 3 (-50%) among adults, and from 132 to 35 μg/m 3 (-73%) among pupils. Solar lamps displaced most kerosene lamp use in at least the short term. If sustained, this could mitigate health impacts of household air pollution in some contexts. Achieving safe levels of exposure for all family members would likely require also addressing use of solid-fuel stoves. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Dielectric Heaters for Testing Spacecraft Nuclear Reactors

    NASA Technical Reports Server (NTRS)

    Sims, William Herbert; Bitteker, Leo; Godfroy, Thomas

    2006-01-01

    A document proposes the development of radio-frequency-(RF)-driven dielectric heaters for non-nuclear thermal testing of the cores of nuclear-fission reactors for spacecraft. Like the electrical-resistance heaters used heretofore for such testing, the dielectric heaters would be inserted in the reactors in place of nuclear fuel rods. A typical heater according to the proposal would consist of a rod of lossy dielectric material sized and shaped like a fuel rod and containing an electrically conductive rod along its center line. Exploiting the dielectric loss mechanism that is usually considered a nuisance in other applications, an RF signal, typically at a frequency .50 MHz and an amplitude between 2 and 5 kV, would be applied to the central conductor to heat the dielectric material. The main advantage of the proposal is that the wiring needed for the RF dielectric heating would be simpler and easier to fabricate than is the wiring needed for resistance heating. In some applications, it might be possible to eliminate all heater wiring and, instead, beam the RF heating power into the dielectric rods from external antennas.

  17. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the structural fire protection requirements for accommodation spaces and modules? 149.641 Section 149.641 Navigation and... national consensus standard, as that term is defined in 29 CFR 1910.2, for the structural fire protection...

  18. 46 CFR 111.85-1 - Electric oil immersion heaters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Electric oil immersion heaters. 111.85-1 Section 111.85-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Electric Oil Immersion Heaters § 111.85-1 Electric oil immersion heaters...

  19. 46 CFR 111.85-1 - Electric oil immersion heaters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Electric oil immersion heaters. 111.85-1 Section 111.85-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Electric Oil Immersion Heaters § 111.85-1 Electric oil immersion heaters...

  20. 46 CFR 111.85-1 - Electric oil immersion heaters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Electric oil immersion heaters. 111.85-1 Section 111.85-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Electric Oil Immersion Heaters § 111.85-1 Electric oil immersion heaters...

  1. 46 CFR 111.85-1 - Electric oil immersion heaters.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Electric oil immersion heaters. 111.85-1 Section 111.85-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Electric Oil Immersion Heaters § 111.85-1 Electric oil immersion heaters...

  2. 46 CFR 111.85-1 - Electric oil immersion heaters.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Electric oil immersion heaters. 111.85-1 Section 111.85-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Electric Oil Immersion Heaters § 111.85-1 Electric oil immersion heaters...

  3. Development of the International Space Station (ISS) Fine Water Mist (FWM) Portable Fire Extinguisher

    NASA Technical Reports Server (NTRS)

    Clements, Anna L.

    2011-01-01

    NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. From a flight hardware design perspective, the fine water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface has been under development for several years. It has gone through several design iterations, and has been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements

  4. KSC-2010-5768

    NASA Image and Video Library

    2010-12-03

    CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket awaits a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, in which all nine Merlin engines will fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Rusty Backer

  5. KSC-2010-5772

    NASA Image and Video Library

    2010-12-03

    CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket awaits a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, in which all nine Merlin engines will fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell

  6. KSC-2010-5774

    NASA Image and Video Library

    2010-12-04

    CAPE CANAVERAL, Fla. -- During a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, all nine Merlin engines of the SpaceX Falcon 9 rocket fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX began to conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which ended after the engines fired at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell

  7. KSC-2010-5775

    NASA Image and Video Library

    2010-12-04

    CAPE CANAVERAL, Fla. -- During a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, all nine Merlin engines of the SpaceX Falcon 9 rocket fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX began to conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which ended after the engines fired at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell

  8. KSC-2010-5776

    NASA Image and Video Library

    2010-12-04

    CAPE CANAVERAL, Fla. -- During a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, all nine Merlin engines of the SpaceX Falcon 9 rocket fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX began to conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which ended after the engines fired at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell

  9. Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, Marc; Seitzler, Matthew

    2017-05-01

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summermore » space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.« less

  10. Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, Marc; Seitzler, Matthew

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summermore » space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.« less

  11. Multi-step heater deployment in a subsurface formation

    DOEpatents

    Mason, Stanley Leroy [Allen, TX

    2012-04-03

    A method for installing a horizontal or inclined subsurface heater includes placing a heating section of a heater in a horizontal or inclined section of a wellbore with an installation tool. The tool is uncoupled from the heating section. A lead in section is mechanically and electrically coupled to the heating section of the heater. The lead-in section is located in an angled or vertical section of the wellbore.

  12. A comparative analysis of liquefied petroleum gas (LPG) and kerosene related burns.

    PubMed

    Ahuja, Rajeev B; Dash, Jayant K; Shrivastava, Prabhat

    2011-12-01

    Previous studies from our department reflected a trend of decreasing incidence of burns culminating from rising income levels, which were bringing about a change in the cooking fuel in many urban households [1,2]. These studies also indicated a changing scenario of increased incidence of burns from LPG mishaps [2]. In the absence of much information on the subject we felt it rather imperative to comparatively study the pattern of burn injuries resulting from LPG and kerosene. This prospective study was conducted on the clinical database of consecutive patients admitted with burns sustained due to LPG and kerosene from 1st January 2009 to 31st May 2010 (17 months). Data recorded for each patient included; age, gender, religion, socioeconomic status, literacy level, type of family unit, marital status, type of dwelling unit, mode of injury and its exact mechanism, place of incident, level of cooking stove, extent of burns (%TBSA), presence of features of inhalation injury, number of patients affected in a single mishap, size of LPG cylinder used, length of hospital stay and mortality. Of 731 flame burn patients in this study, 395 (54%) were due to kerosene burns and 200 (27.4%) from LPG mishaps. Significantly, the majority of injuries, in both the groups, occurred in lower middle class families living as nuclear units, in a single room dwelling, without a separate kitchen. Majority of LPG burns (70.5%, 141 patients) resulted from a gas leak and 25.5% were from cooking negligence (51 patients). 50.5% of kerosene accidents were from 'stove mishaps' and 49% due to cooking negligence. In all kerosene accidents the stove was kept at floor level but in LPG group 20.6% had the stove placed on a platform. There was a slight difference in mean TBSA burns; 51% in kerosene group compared to 41.5% TBSA in LPG group. There were nine episodes in LPG group in which there were more than three burn victims admitted for treatment. Very importantly, 77% patients in LPG group were from

  13. Modeling Evaporation of Drops of Different Kerosenes

    NASA Technical Reports Server (NTRS)

    Bellan, Josette; Harstad, Kenneth

    2007-01-01

    A mathematical model describes the evaporation of drops of a hydrocarbon liquid composed of as many as hundreds of chemical species. The model is intended especially for application to any of several types of kerosenes commonly used as fuels. The concept of continuous thermodynamics, according to which the chemical composition of the evaporating multicomponent liquid is described by use of a probability distribution function (PDF). However, the present model is more generally applicable than is its immediate predecessor.

  14. Controlling an indirect hot water heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capano, J.

    The procedure for servicing a Dunkirk Empire indirect water heater is presented. In this particular case the serviceman found that a wire was loose on the aquastat on the tank. The serviceman checked the wire and the past and tightened the connection. This took care of the problem. A wiring diagram is presented for the home heating system and the hot water heater.

  15. Automated robotic equipment for ultrasonic inspection of pressurizer heater wells

    DOEpatents

    Nachbar, Henry D.; DeRossi, Raymond S.; Mullins, Lawrence E.

    1993-01-01

    A robotic device for remotely inspecting pressurizer heater wells is provided which has the advantages of quickly, precisely, and reliably acquiring data at reasonable cost while also reducing radiation exposure of an operator. The device comprises a prober assembly including a probe which enters a heater well, gathers data regarding the condition of the heater well and transmits a signal carrying that data; a mounting device for mounting the probe assembly at the opening of the heater well so that the probe can enter the heater well; a first motor mounted on the mounting device for providing movement of the probe assembly in an axial direction; and a second motor mounted on the mounting device for providing rotation of the probe assembly. This arrangement enables full inspection of the heater well to be carried out.

  16. Monitoring Fires from Space: a case study in transitioning from research to applications

    NASA Astrophysics Data System (ADS)

    Justice, C. O.; Giglio, L.; Vadrevu, K. P.; Csiszar, I. A.; Schroeder, W.; Davies, D.

    2012-12-01

    This paper discusses the heritage and relationships between science and applications in the context of global satellite-based fire monitoring. The development of algorithms for satellite-based fire detection has been supported primarily by NASA for the polar orbiters with a global focus, and initially by NOAA and more recently by EUMETSAT for the geostationary satellites, with a regional focus. As the feasibility and importance of space-based fire monitoring was recognized, satellite missions were designed to include fire detection capabilities. As a result, the algorithms and accuracy of the detections have improved. Due to the role of fire in the Earth System and its relevance to society, at each step in the development of the sensing capability the research has made a transition into fire-related applications to such an extent that there is now broad use of these data worldwide. The origin of the polar-orbiting satellite fire detection capability was with the AVHRR sensor beginning in the early 1980s, but was transformed with the launch of the EOS MODIS instruments, which included sensor characteristics specifically for fire detection. NASA gave considerable emphasis on the accuracy assessment of the fire detection and the development of fire characterization and burned area products from MODIS. Collaboration between the MODIS Fire Team and the RSAC USFS, initiated in the context of the Montana wildfires of 2001, prompted the development of a Rapid Response System for fire data and eventually led to operational use of MODIS data by the USFS for strategic fire monitoring. Building on this success, the Fire Information for Resource Management Systems (FIRMS) project was funded by NASA Applications to further develop products and services for the fire information community. The FIRMS was developed as a web-based geospatial tool, offering a range of geospatial data services, including SMS text messaging and is now widely used. This system, developed in the research

  17. Extraction of phenol using trialkylphosphine oxides (Cyanex 923) in kerosene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Urtiaga, A.M.; Ortiz, I.

    1997-04-01

    A group of extractants based on phosphine oxides have been reported as an alternative to conventional polar solvents for phenol-liquid-liquid extraction. Among phosphoryl extractants, Cyanex 923 (a mixture of four trialkylphosphine oxides, alkyl = normal, C{sub 6}, C{sub 8}) has proved to combine high extraction efficiency and low water solubility, obviating the necessity of removing the solvent from the aqueous raffinate, a need associated with the use of methyl isobutyl ketone and isopropyl ether, the solvents most widely employed for this application. Phosphoryl extractants are solvating extractants, and are known to form relatively strong and reversible hydrogen bonds with phenols.more » The fact that most of these systems show a strong nonideality in the organic phase makes a general theoretical treatment of the equilibria almost impossible, leading to the necessity of obtaining a large number of data in order to describe the equilibria for design purposes. In this work the effect of the concentration of phenol in the aqueous phase on the partition coefficient for phenol in Cyanex 923-kerosene/water systems is investigated at six different concentrations of the extractant in the organic phase: 1, 5, 10, 20, 50, and 70% v/v of Cyanex 923-kerosene/water systems is investigated at six different concentrations of the extractant in the organic phase: 1, 5, 10, 20, 50, and 70% v/v of Cyanex 923 in kerosene. The initial concentrations of phenol in the aqueous phase were in the 1000 mg/L < C{sub PhOH} < 50,000 mg/L range.« less

  18. Acute treatment with kerosene damages the dermal barrier and alters the distribution of topically applied benzo(a)pyrene in mice.

    PubMed

    LaDow, Kathy; Schumann, Brenda L; Luse, Nicole; Warshawsky, Dave; Pickens, William L; Hoath, Steven B; Talaska, Glenn

    2011-12-01

    The dermal route is important in many occupational exposures. Some materials may reduce the barrier function of the skin to enhance absorption and effect on internal organs. We have reported previously that kerosene cleaning following treatment with used engine oil increased DNA adduct levels in the lungs of mice compared with animals treated with used oil alone. To investigate what other physiological parameters might be affected by kerosene, we conducted in vitro and in vivo measurements of skin barrier function. We also topically applied (3)H-BAP(100 nM in 25 μL acetone) and washed half the mice with 25 μL kerosene 1 hr after carcinogen application. Groups of four mice were euthanized from 1 to 72 hr after treatment. Skin, lungs, and livers were harvested from each animal and stored separately. Kerosene application reduced the barrier function of the skin in vitro beyond the effect of the acetone vehicle and the vehicle plus BAP. In vivo studies indicated that kerosene treatment reduced the barrier function at 4 and 8 hr post application and that the barrier function recovered at 24 hr after a single treatment. The fraction of the radiolabel remaining in the skin of animals treated with (3)H-BAP and washed with kerosene was significantly less than those not washed, beginning at 24 hr (p< 0.05). Fractional distribution to the lungs and livers of these animals became significantly elevated at this time. Kerosene treatment compromises dermal barrier function and the ability of the skin to retain water, enhances carcinogen absorption, and alters organ distribution. This appears to contribute to the increase in BAP DNA adducts we reported earlier.

  19. One-step preparation of biological aviation kerosene by catalytic hydrogenation of waste lard over Pt/SAPO-11

    NASA Astrophysics Data System (ADS)

    Zhang, X.; Chen, Y. B.; Li, X. Y.; Souliyathai, D.; Zhang, S. P.; Wang, Q.; Liu, Q.; Du, J. C.; Zhang, A. M.

    2017-11-01

    Biological aviation kerosene was produced by one-step catalytic hydrotreatment of waste lard oil over Pt/SAPO-11 in a high-pressure fixed bed micro reactor. The influence of reaction conditions such as temperature, pressure, hydrogen oil ratio, and space velocity on the deoxygenation rate, the selectivity of C8-C16 hydrocarbons and the isomerization rate of C8-C16 hydrocarbons have been investigated. The experimental results showed that the temperature of 400°C, pressure of 5 MPa, hydrogen oil ratio of 1000 and space velocity of 1.2 h-1 were the best experimental reaction conditions. Under these conditions, the conversion rate is 96.62%, the selectivity of C8-C16 hydrocarbons is 50.25%, and the isomerization rate of C8-C16 hydrocarbons is 35.68%.

  20. 21 CFR 868.5270 - Breathing system heater.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breathing system heater. 868.5270 Section 868.5270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5270 Breathing system heater. (a...

  1. 21 CFR 868.5270 - Breathing system heater.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breathing system heater. 868.5270 Section 868.5270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5270 Breathing system heater. (a...

  2. WVNS experiences in the detection, monitoring, and leakage from underground tanks containing contaminated kerosene/TBP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valenti, P.J.; McVay, C.W.; Bourgeois, P.

    1986-01-01

    Tanks of radioactively contaminated kerosene/tributyl phosphate (TBP) disposed of at West Valley in 1969, when the plant was being utilized to reprocess commercial nuclear fuel, were determined to be leaking. Contaminated kerosene/TBP was initially detected in November 1983 when samples taken from US Geological Survey monitor wells tested positively for both radioactive and organic constituents. An extensive monitoring, sampling, and analysis program, which involved the installation of approx. 100 monitor points, core bores, and scavenger wells, has been in effect since November 1983 when the migrating kerosene/TBP was initially discovered. Sample analysis has served to provide data on the radionuclidemore » concentration as the kerosene/TBP migrates through the soil. Recent acquisition of a portable gas chromatograph is expected to yield even more definitive information on migration rates. Removal of organics from the scavenger wells will continue while more permanent control measures are finalized. The current efforts will involve the installation of a support structure, erection of a light-weight reusable weather shelter, excavation and potential removal of the tanks and contents, as well as packaging and/or otherwise stabilizing of the resulting waste. The significance of this project is that it will provide a data base for future work in former radioactive disposal sites. A discussion of the monitoring, sampling, and analysis is provided in conjunction with the stabilization efforts.« less

  3. Measure Guideline. Transitioning to a Tankless Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brozyna, K.; Rapport, A.

    2012-09-01

    This measure guideline provides information to help residential builders and retrofitters with the design, specification, selection, implementation, installation, and maintenance issues of transitioning from tank-type water heaters to tankless water heaters.

  4. Fire Suppression and Response

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2004-01-01

    This report is concerned with the following topics regarding fire suppression:What is the relative effectiveness of candidate suppressants to extinguish a representative fire in reduced gravity, including high-O2 mole fraction, low -pressure environments? What are the relative advantages and disadvantages of physically acting and chemically-acting agents in spacecraft fire suppression? What are the O2 mole fraction and absolute pressure below which a fire cannot exist? What effect does gas-phase radiation play in the overall fire and post-fire environments? Are the candidate suppressants effective to extinguish fires on practical solid fuels? What is required to suppress non-flaming fires (smoldering and deep seated fires) in reduced gravity? How can idealized space experiment results be applied to a practical fire scenario? What is the optimal agent deployment strategy for space fire suppression?

  5. Heat transfer, friction, and rheological characteristics of antimisting kerosene

    NASA Technical Reports Server (NTRS)

    Matthys, E.; Sarohia, V.

    1985-01-01

    Experiments were performed to determine the skin friction and heat transfer behavior of antimisting kerosene (AMK) in pipe flows. The additive used was FM-9. Based on the results of the experiments, which identify high viscosity and viscoelasticity for AMK, it is recommended that AMK be degraded. Sufficient degradation produces behavior similar to that of jet A.

  6. Wildland Arson as Clandestine Resource Management: A Space-Time Permutation Analysis and Classification of Informal Fire Management Regimes in Georgia, USA

    NASA Astrophysics Data System (ADS)

    Coughlan, Michael R.

    2016-05-01

    Forest managers are increasingly recognizing the value of disturbance-based land management techniques such as prescribed burning. Unauthorized, "arson" fires are common in the southeastern United States where a legacy of agrarian cultural heritage persists amidst an increasingly forest-dominated landscape. This paper reexamines unauthorized fire-setting in the state of Georgia, USA from a historical ecology perspective that aims to contribute to historically informed, disturbance-based land management. A space-time permutation analysis is employed to discriminate systematic, management-oriented unauthorized fires from more arbitrary or socially deviant fire-setting behaviors. This paper argues that statistically significant space-time clusters of unauthorized fire occurrence represent informal management regimes linked to the legacy of traditional land management practices. Recent scholarship has pointed out that traditional management has actively promoted sustainable resource use and, in some cases, enhanced biodiversity often through the use of fire. Despite broad-scale displacement of traditional management during the 20th century, informal management practices may locally circumvent more formal and regionally dominant management regimes. Space-time permutation analysis identified 29 statistically significant fire regimes for the state of Georgia. The identified regimes are classified by region and land cover type and their implications for historically informed disturbance-based resource management are discussed.

  7. Wildland Arson as Clandestine Resource Management: A Space-Time Permutation Analysis and Classification of Informal Fire Management Regimes in Georgia, USA.

    PubMed

    Coughlan, Michael R

    2016-05-01

    Forest managers are increasingly recognizing the value of disturbance-based land management techniques such as prescribed burning. Unauthorized, "arson" fires are common in the southeastern United States where a legacy of agrarian cultural heritage persists amidst an increasingly forest-dominated landscape. This paper reexamines unauthorized fire-setting in the state of Georgia, USA from a historical ecology perspective that aims to contribute to historically informed, disturbance-based land management. A space-time permutation analysis is employed to discriminate systematic, management-oriented unauthorized fires from more arbitrary or socially deviant fire-setting behaviors. This paper argues that statistically significant space-time clusters of unauthorized fire occurrence represent informal management regimes linked to the legacy of traditional land management practices. Recent scholarship has pointed out that traditional management has actively promoted sustainable resource use and, in some cases, enhanced biodiversity often through the use of fire. Despite broad-scale displacement of traditional management during the 20th century, informal management practices may locally circumvent more formal and regionally dominant management regimes. Space-time permutation analysis identified 29 statistically significant fire regimes for the state of Georgia. The identified regimes are classified by region and land cover type and their implications for historically informed disturbance-based resource management are discussed.

  8. Emission characteristics of kerosene-air spray combustion with plasma assistance

    NASA Astrophysics Data System (ADS)

    Liu, Xingjian; He, Liming; Zeng, Hao; Jin, Tao; Chen, Yi; Zhang, Yihan; Liu, Pengfei

    2015-09-01

    A plasma assisted combustion system for combustion of kerosene-air mixtures was developed to study emission levels of O2, CO2, CO, and NOx. The emission measurement was conducted by Testo 350-Pro Flue Gas Analyzer. The effect of duty ratio, feedstock gas flow rate and applied voltage on emission performance has been analyzed. The results show that O2 and CO emissions reduce with an increase of applied voltage, while CO2 and NOx emissions increase. Besides, when duty ratio or feedstock gas flow rate decreases, the same emission results would appear. The emission spectrum of the air plasma of plasma assisted combustion actuator was also registered to analyze the kinetic enhancement effect of plasma, and the generation of ozone was believed to be the main factor that plasma makes a difference in our experiment. These results are valuable for the future optimization of kerosene-fueled aircraft engine when using plasma assisted combustion devices to exert emission control.

  9. A seven-year review of accidental kerosene poisoning in children at Aminu Kano Teaching Hospital, Kano.

    PubMed

    Belonwu, R O; Adeleke, S I

    2008-01-01

    Accidental ingestion of kerosene is a potential source of morbidity and mortality in children. The objectives of the study are to determine to magnitude of the problem and proffer feasible solutions to reduce the frequency of occurrence. The medical records of all cases of kerosene poisoning admitted into Paediatric Medical Ward and Emergency Paediatric Unit were identified and relevant data extracted and analysed. Kerosene poisoning constituted 55 (1.2%) of cases of all paediatric admissions within the period (Jan 1999 Dec 2005). The study showed that children 4 months to 8 years were affected with peak age of 18 months. Thirty-four (61.8%) of the cases were aged below 2 years which conforms to findings in earlier studies in Nigeria. Main clinical feature was cough with difficulty in breathing in 52 (94.5%) of cases. Others features noted were central nervous system involvement (14.5%), vomiting (20%), and fever 16 (29.1%). There were 3 deaths giving the mortality of 5.5%. The study has revealed that kerosene poisoning is a significant cause of morbidity and mortality. Government policies that will enhance the standard of living of people and education of parents/care givers are the identified imperatives for reduction of the problem.

  10. The Production of Biodiesel and Bio-kerosene from Coconut Oil Using Microwave Assisted Reaction

    NASA Astrophysics Data System (ADS)

    SAIFUDDIN, N.; SITI FAZLILI, A.; KUMARAN, P.; PEI-JUA, N.; PRIATHASHINI, P.

    2016-03-01

    Biofuels including biodiesel, an alternative fuel, is renewable, environmentally friendly, non-toxic and low emissions. The raw material used in this work was coconut oil, which contained saturated fatty acids about 90% with high percentage of medium chain (C8-C12), especially lauric acid and myristic acid. The purpose of this research was to study the effect of power and NaOH catalyst in transesterification assisted by microwave for production of biofuels (biodiesel and bio-kerosene) derived from coconut oil. The reaction was performed with oil and methanol using mole ratio of 1:6, catalyst concentration of 0.6% with microwave power at 100W, 180W, 300W, 450W, 600W, and 850W. The reaction time was set at of 3, 5, 7, 10 and 15 min. The results showed that microwave could accelerate the transesterification process to produce biodiesel and bio-kerosene using NaOH catalyst. The highest yield of biodiesel was 97.17 %, or 99.05 % conversion at 5 min and 100W microwave power. Meanwhile, the bio-kerosene obtained was 65% after distillation.

  11. 46 CFR 111.70-5 - Heater circuits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-5 Heater circuits. (a) If an enclosure for a motor, master switch, or other equipment has an electric heater inside the enclosure that is energized.... (b) If the location of the enclosure for a motor, master switch, or other equipment for deck...

  12. Resolving vorticity-driven lateral fire spread using the WRF-Fire coupled atmosphere-fire numerical model

    NASA Astrophysics Data System (ADS)

    Simpson, C. C.; Sharples, J. J.; Evans, J. P.

    2014-05-01

    Fire channelling is a form of dynamic fire behaviour, during which a wildland fire spreads rapidly across a steep lee-facing slope in a direction transverse to the background winds, and is often accompanied by a downwind extension of the active flaming region and extreme pyro-convection. Recent work using the WRF-Fire coupled atmosphere-fire model has demonstrated that fire channelling can be characterised as vorticity-driven lateral fire spread (VDLS). In this study, 16 simulations are conducted using WRF-Fire to examine the sensitivity of resolving VDLS to spatial resolution and atmosphere-fire coupling within the WRF-Fire model framework. The horizontal grid spacing is varied between 25 and 90 m, and the two-way atmosphere-fire coupling is either enabled or disabled. At high spatial resolution, the atmosphere-fire coupling increases the peak uphill and lateral spread rate by a factor of up to 2.7 and 9.5. The enhancement of the uphill and lateral spread rate diminishes at coarser spatial resolution, and VDLS is not modelled for a horizontal grid spacing of 90 m. The laterally spreading fire fronts become the dominant contributors of the extreme pyro-convection. The resolved fire-induced vortices responsible for driving the lateral spread in the coupled simulations have non-zero vorticity along each unit vector direction, and develop due to an interaction between the background winds and vertical return circulations generated at the flank of the fire front as part of the pyro-convective updraft. The results presented in this study demonstrate that both high spatial resolution and two-way atmosphere-fire coupling are required to reproduce VDLS within the current WRF-Fire model framework.

  13. Three-phase heaters with common overburden sections for heating subsurface formations

    DOEpatents

    Vinegar, Harold J [Bellaire, TX

    2012-02-14

    A heating system for a subsurface formation is described. The heating system includes three substantially u-shaped heaters with first end portions of the heaters being electrically coupled to a single, three-phase wye transformer and second end portions of the heaters being electrically coupled to each other and/or to ground. The three heaters may enter the formation through a first common wellbore and exit the formation through a second common wellbore so that the magnetic fields of the three heaters at least partially cancel out in the common wellbores.

  14. [Ecological/hygienic and toxicological evaluation of combustion products of aviation kerosene and liquefied natural gas].

    PubMed

    Afanas'ev, R V; Berezin, G I; Raznoschikov, V V

    2006-01-01

    Products of kerosene combustion in the present-day aeroengines contain more than 200 compounds of incomplete combustion, partial oxidation, and thermal decomposition of fuel and oil. Most of these are strong toxicants for humans. Increase of temperature in the turbine engine combustion chamber led to production of very toxic nitrogen oxides. In search for the ecologically safe and less toxic alternative attention of fuel engineers was drawn to liquefied natural gas which compares well and even excels kerosene in ecological, economic and many other respects.

  15. Development of micro-heaters with optimized temperature compensation design for gas sensors.

    PubMed

    Hwang, Woo-Jin; Shin, Kyu-Sik; Roh, Ji-Hyoung; Lee, Dae-Sung; Choa, Sung-Hoon

    2011-01-01

    One of the key components of a chemical gas sensor is a MEMS micro-heater. Micro-heaters are used in both semiconductor gas sensors and NDIR gas sensors; however they each require different heat dissipation characteristics. For the semiconductor gas sensors, a uniform temperature is required over a wide area of the heater. On the other hand, for the NDIR gas sensor, the micro-heater needs high levels of infrared radiation in order to increase sensitivity. In this study, a novel design of a poly-Si micro-heater is proposed to improve the uniformity of heat dissipation on the heating plate. Temperature uniformity of the micro-heater is achieved by compensating for the variation in power consumption around the perimeter of the heater. With the power compensated design, the uniform heating area is increased by 2.5 times and the average temperature goes up by 40 °C. Therefore, this power compensated micro-heater design is suitable for a semiconductor gas sensor. Meanwhile, the poly-Si micro-heater without compensation shows a higher level of infrared radiation under equal power consumption conditions. This indicates that the micro-heater without compensation is more suitable for a NDIR gas sensor. Furthermore, the micro-heater shows a short response time of less than 20 ms, indicating a very high efficiency of pulse driving.

  16. Recovery Act: Water Heater ZigBee Open Standard Wireless Controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, William P.; Buescher, Tom

    2014-04-30

    The objective of Emerson's Water Heater ZigBee Open Standard Wireless Controller is to support the DOE's AARA priority for Clean, Secure Energy by designing a water heater control that levels out residential and small business peak electricity demand through thermal energy storage in the water heater tank.

  17. Summer Work Experience: Determining Methane Combustion Mechanisms and Sub-Scale Diffuser Properties for Space Transporation System Engine Testing

    NASA Technical Reports Server (NTRS)

    Williams, Powtawche N.

    1998-01-01

    To assess engine performance during the testing of Space Shuttle Main Engines (SSMEs), the design of an optimal altitude diffuser is studied for future Space Transportation Systems (STS). For other Space Transportation Systems, rocket propellant using kerosene is also studied. Methane and dodecane have similar reaction schemes as kerosene, and are used to simulate kerosene combustion processes at various temperatures. The equations for the methane combustion mechanism at high temperature are given, and engine combustion is simulated on the General Aerodynamic Simulation Program (GASP). The successful design of an altitude diffuser depends on the study of a sub-scaled diffuser model tested through two-dimensional (2-D) flow-techniques. Subroutines given calculate the static temperature and pressure at each Mach number within the diffuser flow. Implementing these subroutines into program code for the properties of 2-D compressible fluid flow determines all fluid characteristics, and will be used in the development of an optimal diffuser design.

  18. Thermally driven self-healing using copper nanofiber heater

    NASA Astrophysics Data System (ADS)

    Lee, Min Wook; Jo, Hong Seok; Yoon, Sam S.; Yarin, Alexander L.

    2017-07-01

    Nano-textured transparent heaters made of copper nanofibers (CuNFs) are used to facilitate accelerated self-healing of bromobutyl rubber (BIIR). The heater and BIIR layer are separately deposited on each side of a transparent flexible polyethylene terephthalate (PET) substrate. A pre-notched crack on the BIIR layer was bridged due to heating facilitated by CuNFs. In the corrosion test, a cracked BIIR layer covered a steel substrate. An accelerated self-healing of the crack due to the transparent copper nanofiber heater facilitated an anti-corrosion protective effect of the BIIR layer.

  19. 46 CFR 27.301 - What are the requirements for fire pumps, fire mains, and fire hoses on towing vessels?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... must provide for your towing vessel either a self-priming, power-driven, fixed fire-pump, a fire main... fire hydrants with attached hose to reach any part of the machinery space using a single length of fire... providing a solid stream and a spray pattern. (e) The portable fire pump must be self-priming and power...

  20. 46 CFR 27.301 - What are the requirements for fire pumps, fire mains, and fire hoses on towing vessels?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... must provide for your towing vessel either a self-priming, power-driven, fixed fire-pump, a fire main... fire hydrants with attached hose to reach any part of the machinery space using a single length of fire... providing a solid stream and a spray pattern. (e) The portable fire pump must be self-priming and power...

  1. Kerosene: Contributing agent to xylene as a clearing agent in tissue processing.

    PubMed

    Shah, Amisha Ashokkumar; Kulkarni, Dinraj; Ingale, Yashwant; Koshy, Ajit V; Bhagalia, Sanjay; Bomble, Nikhil

    2017-01-01

    Research methodology in oral and maxillofacial pathology has illimitable potential. The tissue processing involves many steps of which one of the most important step is "Clearing," which is a process of replacing dehydrant with a substance which is miscible with embedding medium or paraffin wax. Xylene is one of the common clearing agents used in laboratory, but it is also hazardous. The main aim of this study is to substitute conventionally used xylene by a mixture of kerosene and xylene in clearing steps without altering the morphology and staining characteristics of tissue sections. This will also minimize the toxic effects and tend to be more economical. One hundred and twenty bits of tissue samples were collected, each randomly separated into 4 groups (A, B, C and D) and kept for routine tissue processing till the step of clearing; during the step of clearing instead of conventional xylene, we used mixture of xylene and kerosene in 4 ratios ([A-K:X - 50:50]; [B-K:X - 70:30]; [C - Ab. Kerosene]; [D - Ab. Xylene - as control]) and observed for the light microscopic study adopting H and E staining, IHC (D2-40), Special stains (periodic acid-Schiff and congo red) procedure. The result was subjected to statistical analysis by using Fisher's exact test. The results obtained from the present study were compared with control group, i.e., D and it was observed that Groups A and B were absolutely cleared without altering the morphology of tissue and cellular details; optimum embedding characteristics and better staining characteristics were also noted, whereas Group C presents poor staining characteristics with reduced cellular details. Embedded tissues in Group C presented with rough, irregular surface and also appeared shrunken. Combined mixture of xylene and kerosene as a clearing agent in different ratio, i.e., Group A (K:X - 50:50) and B (K:X - 70:30) can be used without posing any health risk or compromising the cellular integrity.

  2. Natural convection in a parallel-plate vertical channel with discrete heating by two flush-mounted heaters: effect of the clearance between the heaters

    NASA Astrophysics Data System (ADS)

    Sarper, Bugra; Saglam, Mehmet; Aydin, Orhan; Avci, Mete

    2018-04-01

    In this study, natural convection in a vertical channel is studied experimentally and numerically. One of the channel walls is heated discretely by two flush-mounted heaters while the other is insulated. The effects of the clearance between the heaters on heat transfer and hot spot temperature while total length of the heaters keeps constant are investigated. Four different settlements of two discrete heaters are comparatively examined. Air is used as the working fluid. The range of the modified Grashof number covers the values between 9.6 × 105 and 1.53 × 10.7 Surface to surface radiation is taken into account. Flow visualizations and temperature measurements are performed in the experimental study. Numerical computations are performed using the commercial CFD code ANSYS FLUENT. The results are represented as the variations of surface temperature, hot spot temperature and Nusselt number with the modified Grashof number and the clearance between the heaters as well as velocity and temperature variations of the fluid.

  3. A silicon nanowire heater and thermometer

    NASA Astrophysics Data System (ADS)

    Zhao, Xingyan; Dan, Yaping

    2017-07-01

    In the thermal conductivity measurements of thermoelectric materials, heaters and thermometers made of the same semiconducting materials under test, forming a homogeneous system, will significantly simplify fabrication and integration. In this work, we demonstrate a high-performance heater and thermometer made of single silicon nanowires (SiNWs). The SiNWs are patterned out of a silicon-on-insulator wafer by CMOS-compatible fabrication processes. The electronic properties of the nanowires are characterized by four-probe and low temperature Hall effect measurements. The I-V curves of the nanowires are linear at small voltage bias. The temperature dependence of the nanowire resistance allows the nanowire to be used as a highly sensitive thermometer. At high voltage bias, the I-V curves of the nanowire become nonlinear due to the effect of Joule heating. The temperature of the nanowire heater can be accurately monitored by the nanowire itself as a thermometer.

  4. Kerosene poisoning in children in Iraq.

    PubMed Central

    Nagi, N. A.; Abdulallah, Z. A.

    1995-01-01

    One hundred and three children with kerosene poisoning were studied. The majority of the patients were under five years of age and included a newborn baby. More patients were seen in spring and fewer in winter months. Most of the patients were children of poor families living in overcrowded conditions. Negligence and ignorance were the main causes of poisoning. Respiratory and central nervous systems were mainly involved. Chest X-ray abnormalities were frequently seen. The patients were treated symptomatically. Only one patient died, he had been in a coma on admission to the hospital. All other patients had rapid and complete recoveries. PMID:7567734

  5. Solar kerosene from H2O and CO2

    NASA Astrophysics Data System (ADS)

    Furler, P.; Marxer, D.; Scheffe, J.; Reinalda, D.; Geerlings, H.; Falter, C.; Batteiger, V.; Sizmann, A.; Steinfeld, A.

    2017-06-01

    The entire production chain for renewable kerosene obtained directly from sunlight, H2O, and CO2 is experimentally demonstrated. The key component of the production process is a high-temperature solar reactor containing a reticulated porous ceramic (RPC) structure made of ceria, which enables the splitting of H2O and CO2 via a 2-step thermochemical redox cycle. In the 1st reduction step, ceria is endo-thermally reduced using concentrated solar radiation as the energy source of process heat. In the 2nd oxidation step, nonstoichiometric ceria reacts with H2O and CO2 to form H2 and CO - syngas - which is finally converted into kerosene by the Fischer-Tropsch process. The RPC featured dual-scale porosity for enhanced heat and mass transfer: mm-size pores for volumetric radiation absorption during the reduction step and μm-size pores within its struts for fast kinetics during the oxidation step. We report on the engineering design of the solar reactor and the experimental demonstration of over 290 consecutive redox cycles for producing high-quality syngas suitable for the processing of liquid hydrocarbon fuels.

  6. Thin film heater for removable volatile protecting coatings.

    PubMed

    Karim, Abid

    2013-01-01

    Freshly coated aluminum mirrors have excellent reflectivity at far ultraviolet wavelengths. However, reflectivity rapidly degrades when the mirror surfaces are exposed to atmosphere. In order to avoid this problem, freshly coated aluminum surface can be protected by over-coating of a removable volatile protecting coating. This protecting coating can be re-evaporated by controlled heating or by some other methods when required. This type of removable coating has immediate application in UV space astronomy. The purpose of this paper is to demonstrate the feasibility of re-evaporation of removable volatile Zn protecting coating using a NiCr thin film heater without affecting the reflection properties of Al mirror surfaces.

  7. Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration

    DOEpatents

    Vinegar, Harold J.; Sandberg, Chester Ledlie

    2010-11-09

    A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

  8. Emission of polycyclic aromatic hydrocarbons, toxicity, and mutagenicity from domestic cooking using sawdust briquettes, wood, and kerosene.

    PubMed

    Kim, OanhNguyenThi; Nghiem, Le Hoang; Phyu, Yin Latt

    2002-03-01

    Smoke samples, in both gas and particulate matter (PM) phases, of the three domestic stoves were collected using U.S. EPA modified method 5 and were analyzed for 17 PAH (HPLC-UV), acute toxicity (Microtox test), and mutagenicity (Amestest). The gas phase of smoke contributed > or = 95% of 17 PAH, > or = 96% of toxicity, and > or = 60% of mutagenicity. The highest emission factor of 17 PAH was from sawdust briquettes (260 mg/kg), but the highest emission of 11 genotoxic PAH was from kerosene (28 mg/kg). PM samples of kerosene smoke were not toxic. The total toxicity emission factor was the highest from sawdust, followed by kerosene and wood fuel. Smoke samples from the kerosene stove were not mutagenic. TA98 indicated the presence of both direct and indirect mutagenic activities in PM samples of sawdust and wood fuel but only direct mutagenic activities in the gas phase. TA100 detected only direct mutagenic activities in both PM and gas-phase samples. The higher mutagenicity emission factor was from wood fuel, 12 x 10(6) revertants/kg (TA100-S9) and 3.5 x 10(6) (TA98-S9), and lower from sawdust, 2.9 x 10(6) (TA100-S9) and 2.8 x 10(6) (TA98-S9). The low burning rate and high efficiency of a kerosene stove have resulted in the lowest PAH, toxicity, and mutagenicity emissions from daily cooking activities. The bioassays produced toxicity and mutagenicity results in correspondence with the PAH content of samples. The tests could be used for a quick assessment of potential health risks.

  9. [Comparative studies on the toxicity of various dieelectrics, kerosene derivatives, used in the electroerosion technic. I. Morphological, cytoenzymatic and biochemical changes in the liver of rats chronically exposed to kerosene hydrocarbons].

    PubMed

    Starek, A; Kamiński, M

    1982-01-01

    Rats exposed to cosmetic kerosene mists (odourless kerosene), concentration of 75 and 300 mg/m3 for 14 days, underwent morphological and cytoenzymatic liver tests and biochemical tests of lipids composition in this organ. In addition, lipids concentration and activity of test--enzymes in blood serum were determined. The findings were: passive congestion, fine--droplet fatty degeneration in I zones of clusters and increased number of Browicz--Kupffer's phagocytes near liver triads. Those changes were accompanied by: decreased activity of succinic dehydrogenese (SDH), tetrazolic NADPH--reductase (NADPH-r.t.) and glucose-6-phosphatase (G-6-P-ase) and increased activity of adenosine triphosphatase (Mg++-ATP-ase) and acid phosphatase (AcP). In blood serum medium increase of base phosphatase (AP), 5-nucleotidase (5-Nt) and leucyloaminepeptidase (LAP) and decreased activity of prothrombin (Pt) were found. In addition, it was demonstrated that liver steatosis was characterized by cumulation of free fatty acids, phospholipids and cholesterol esters with simultaneous decrease in triglycerides content in this organ. The obtained results indicate that changes induced by kerosene hydrocarbons in liver are focal and cumulate in I zones of liver clusters. The degree of lesion varies with the extent of exposure, and results from toxic effects of this preparation on hepatic cells lypoproteid membranes.

  10. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maguire, Jeff; Burch, Jay; Merrigan, Tim

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently re-emerged on the U.S. market, and they have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine the actual energy consumption of a HPWH in different U.S. regions, annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the United States. The simulations included a benchmark home to take into account interactions between themore » space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.« less

  11. Abatement of SF{sub 6} and CF{sub 4} using an enhanced kerosene microwave plasma burner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Dong Hun; Hong, Yong Cheol; Cho, Soon Cheon

    2006-11-15

    A kerosene microwave plasma burner was presented as a tool for abatement of SF{sub 6} and CF{sub 4} gases, which cause global warming. The plasma burner operates by injecting kerosene as a liquid hydrocarbon fuel into a microwave plasma torch and by mixing the resultant gaseous hydrogen and carbon compounds with air or oxygen (O{sub 2}) gas. The abatement of SF{sub 6} and CF{sub 4}, by making use of the kerosene plasma burner, was conducted in terms of nitrogen (N{sub 2}) flow rates. The destruction and removal efficiency of the burner were achieved up to 99.9999% for 0.1 liters permore » minute (lpm) SF{sub 6} in 120 lpm N{sub 2} and 99.3% for 0.05 lpm CF{sub 4} in 60 lpm N{sub 2}, revealing that the microwave plasma burner can effectively eliminate perfluorocompounds emitted from the semiconductor industries.« less

  12. Materials for a Stirling engine heater head

    NASA Technical Reports Server (NTRS)

    Noble, J. E.; Lehmann, G. A.; Emigh, S. G.

    1990-01-01

    Work done on the 25-kW advanced Stirling conversion system (ASCS) terrestrial solar program in establishing criteria and selecting materials for the engine heater head and heater tubes is described. Various mechanisms contributing to incompatibility between materials are identified and discussed. Large thermal gradients, coupled with requirements for long life (60,000 h at temperature) and a large number of heatup and cooldown cycles (20,000) drive the design from a structural standpoint. The pressurized cylinder is checked for creep rupture, localized yielding, reverse plasticity, creep and fatigue damage, and creep ratcheting, in addition to the basic requirements for bust and proof pressure. In general, creep rupture and creep and fatigue interaction are the dominant factors in the design. A wide range of materials for the heater head and tubes was evaluated. Factors involved in the assessment were strength and effect on engine efficiency, reliability, and cost. A preliminary selection of Inconel 713LC for the heater head is based on acceptable structural properties but driven mainly by low cost. The criteria for failure, the structural analysis, and the material characteristics with basis for selection are discussed.

  13. A programmable heater control circuit for spacecraft

    NASA Technical Reports Server (NTRS)

    Nguyen, D. D.; Owen, J. W.; Smith, D. A.; Lewter, W. J.

    1994-01-01

    Spacecraft thermal control is accomplished for many components through use of multilayer insulation systems, electrical heaters, and radiator systems. The heaters are commanded to maintain component temperatures within design specifications. The programmable heater control circuit (PHCC) was designed to obtain an effective and efficient means of spacecraft thermal control. The hybrid circuit provides use of control instrumentation as temperature data, available to the spacecraft central data system, reprogramming capability of the local microprocessor during the spacecraft's mission, and the elimination of significant spacecraft wiring. The hybrid integrated circuit has a temperature sensing and conditioning circuit, a microprocessor, and a heater power and control circuit. The device is miniature and housed in a volume which allows physical integration with the component to be controlled. Applications might include alternate battery-powered logic-circuit configurations. A prototype unit with appropriate physical and functional interfaces was procured for testing. The physical functionality and the feasibility of fabrication of the hybrid integrated circuit were successfully verified. The remaining work to develop a flight-qualified device includes fabrication and testing of a Mil-certified part. An option for completing the PHCC flight qualification testing is to enter into a joint venture with industry.

  14. Environmental Loss Characterization of an Advanced Stirling Convertor (ASC-E2) Insulation Package Using a Mock Heater Head

    NASA Technical Reports Server (NTRS)

    Schifer, Nicholas A.; Briggs, Maxwell H.

    2012-01-01

    The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two highefficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a specified electrical power output for a given net heat input. While electrical power output can be precisely quantified, thermal power input to the Stirling cycle cannot be directly measured. In an effort to improve net heat input predictions, the Mock Heater Head was developed with the same relative thermal paths as a convertor using a conducting rod to represent the Stirling cycle and tested to provide a direct comparison to numerical and empirical models used to predict convertor net heat input. The Mock Heater Head also served as the pathfinder for a higher fidelity version of validation test hardware, known as the Thermal Standard. This paper describes how the Mock Heater Head was tested and utilized to validate a process for the Thermal Standard.

  15. Reducing residential solid fuel combustion through electrified space heating leads to substantial air quality, health and climate benefits in China's Beijing-Tianjin-Hebei region

    NASA Astrophysics Data System (ADS)

    Yang, J.; Mauzerall, D. L.

    2017-12-01

    During periods of high pollution in winter, household space heating can contribute more than half of PM2.5 concentrations in China's Beijing-Tianjin-Hebei (BTH) region. The majority of rural households and some urban households in the region still heat with small stoves and solid fuels such as raw coal, coal briquettes and biomass. Thus, reducing emissions from residential space heating has become a top priority of the Chinese government's air pollution mitigation plan. Electrified space heating is a promising alternative to solid fuel. However, there is little analysis of the air quality and climate implications of choosing various electrified heating devices and utilizing different electricity sources. Here we conduct an integrated assessment of the air quality, human health and climate implications of various electrified heating scenarios in the BTH region using the Weather Research and Forecasting model with Chemistry. We use the Multi-resolution Emission Inventory for China for the year 2012 as our base case and design two electrification scenarios in which either direct resistance heaters or air source heat pumps are installed to replace all household heating stoves. We initially assume all electrified heating devices use electricity from supercritical coal-fired power plants. We find that installing air source heat pumps reduces CO2 emissions and premature deaths due to PM2.5 pollution more than resistance heaters, relative to the base case. The increased health and climate benefits of heat pumps occur because they have a higher heat conversion efficiency and thus require less electricity for space heating than resistance heaters. We also find that with the same heat pump installation, a hybrid electricity source (40% of the electricity generated from renewable sources and the rest from coal) further reduces both CO2 emissions and premature deaths than using electricity only from coal. Our study demonstrates the air pollution and CO2 mitigation potential and

  16. Precise Heater Controller with rf-Biased Josephson Junctions

    NASA Technical Reports Server (NTRS)

    Green, Colin J.; Sergatskov, Dmitri A.; Duncan, R. V.

    2003-01-01

    Paramagnetic susceptibility thermometers used in fundamental physics experiments are capable of measuring temperature changes with a precision of a part in 2 x 10(exp 10). However, heater controllers are only able to control open-loop power dissipation to about a part in 10(exp 5). We used an array of rf-biased Josephson junctions to precisely control the electrical power dissipation in a heater resistor mounted on a thermally isolated cryogenic platform. Theoretically, this method is capable of controlling the electrical power dissipation to better than a part in 10(exp 12). However, this level has not yet been demonstrated experimentally. The experiment consists of a liquid helium cell that also functions as a high-resolution PdMn thermometer, with a heater resistor mounted on it. The cell is thermally connected to a temperature-controlled cooling stage via a weak thermal link. The heater resistor is electrically connected to the array of Josephson junctions using superconducting wire. An rf-biased array of capacitively shunted Josephson junctions drives the voltage across the heater. The quantized voltage across the resistor is Vn = nf(h/2e), where h is Planck's constant, f is the array biasing frequency, e is the charge of an electron, and n is the integer quantum state of the Josephson array. This results in an electrical power dissipation on the cell of Pn = (Vn)(sup 2/R), where R is the heater resistance. The change of the quantum state of the array changes the power dissipated in the heater, which in turn, results in the change of the cell temperature. This temperature change is compared to the expected values based on the known thermal standoff resistance of the cell from the cooling stage. We will present our initial experimental results and discuss future improvements. This work has been funded by the Fundamental Physics Discipline of the Microgravity Science Office of NASA, and supported by a no-cost equipment loan from Sandia National Laboratories.

  17. Jet Fuel Kerosene is not Immunosuppressive in Mice or Rats Following Inhalation for 28 Days

    PubMed Central

    White, Kimber L.; DeLorme, Michael P.; Beatty, Patrick W.; Smith, Matthew J.; Peachee, Vanessa L.

    2013-01-01

    Previous reports indicated that inhalation of JP-8 aviation turbine fuel is immunosuppressive. However, in some of those studies, the exposure concentrations were underestimated, and percent of test article as vapor or aerosol was not determined. Furthermore, it is unknown whether the observed effects are attributable to the base hydrocarbon fuel (jet fuel kerosene) or to the various fuel additives in jet fuels. The present studies were conducted, in compliance with Good Laboratory Practice (GLP) regulations, to evaluate the effects of jet fuel kerosene on the immune system, in conjunction with an accurate, quantitative characterization of the aerosol and vapor exposure concentrations. Two female rodent species (B6C3F1 mice and Crl:CD rats) were exposed by nose-only inhalation to jet fuel kerosene at targeted concentrations of 0, 500, 1000, or 2000 mg/m3 for 6 h daily for 28 d. Humoral, cell-mediated, and innate immune functions were subsequently evaluated. No marked effects were observed in either species on body weights, spleen or thymus weights, the T-dependent antibody-forming cell response (plaque assay), or the delayed-type hypersensitivity (DTH) response. With a few exceptions, spleen cell numbers and phenotypes were also unaffected. Natural killer (NK) cell activity in mice was unaffected, while the NK assessment in rats was not usable due to an unusually low response in all groups. These studies demonstrate that inhalation of jet fuel kerosene for 28 d at levels up to 2000 mg/m3 did not adversely affect the functional immune responses of female mice and rats. PMID:24028664

  18. Jet fuel kerosene is not immunosuppressive in mice or rats following inhalation for 28 days.

    PubMed

    White, Kimber L; DeLorme, Michael P; Beatty, Patrick W; Smith, Matthew J; Peachee, Vanessa L

    2013-01-01

    Previous reports indicated that inhalation of JP-8 aviation turbine fuel is immunosuppressive. However, in some of those studies, the exposure concentrations were underestimated, and percent of test article as vapor or aerosol was not determined. Furthermore, it is unknown whether the observed effects are attributable to the base hydrocarbon fuel (jet fuel kerosene) or to the various fuel additives in jet fuels. The present studies were conducted, in compliance with Good Laboratory Practice (GLP) regulations, to evaluate the effects of jet fuel kerosene on the immune system, in conjunction with an accurate, quantitative characterization of the aerosol and vapor exposure concentrations. Two female rodent species (B6C3F1 mice and Crl:CD rats) were exposed by nose-only inhalation to jet fuel kerosene at targeted concentrations of 0, 500, 1000, or 2000 mg/m(3) for 6 h daily for 28 d. Humoral, cell-mediated, and innate immune functions were subsequently evaluated. No marked effects were observed in either species on body weights, spleen or thymus weights, the T-dependent antibody-forming cell response (plaque assay), or the delayed-type hypersensitivity (DTH) response. With a few exceptions, spleen cell numbers and phenotypes were also unaffected. Natural killer (NK) cell activity in mice was unaffected, while the NK assessment in rats was not usable due to an unusually low response in all groups. These studies demonstrate that inhalation of jet fuel kerosene for 28 d at levels up to 2000 mg/m(3) did not adversely affect the functional immune responses of female mice and rats.

  19. 88. ARAIII. "Petrochem" heater is hoisted over south exterior wall ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    88. ARA-III. "Petro-chem" heater is hoisted over south exterior wall of heater pit in GCRE reactor building (ARA-608). Printing on heater says, "Petro-chem iso-flow furnace; American industrial fabrications, inc." Camera facing north. January 7, 1959. Ineel photo no. 529-124. Photographer: Ken Mansfield. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  20. Temperature limited heater utilizing non-ferromagnetic conductor

    DOEpatents

    Vinegar,; Harold J. , Harris; Kelvin, Christopher [Houston, TX

    2012-07-17

    A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

  1. Engineering solutions for polymer composites solar water heaters production

    NASA Astrophysics Data System (ADS)

    Frid, S. E.; Arsatov, A. V.; Oshchepkov, M. Yu.

    2016-06-01

    Analysis of engineering solutions aimed at a considerable decrease of solar water heaters cost via the use of polymer composites in heaters construction and solar collector and heat storage integration into a single device representing an integrated unit results are considered. Possibilities of creating solar water heaters of only three components and changing welding, soldering, mechanical treatment, and assembly of a complicate construction for large components molding of polymer composites and their gluing are demonstrated. Materials of unit components and engineering solutions for their manufacturing are analyzed with consideration for construction requirements of solar water heaters. Optimal materials are fiber glass and carbon-filled plastics based on hot-cure thermosets, and an optimal molding technology is hot molding. It is necessary to manufacture the absorbing panel as corrugated and to use a special paint as its selective coating. Parameters of the unit have been optimized by calculation. Developed two-dimensional numerical model of the unit demonstrates good agreement with the experiment. Optimal ratio of daily load to receiving surface area of a solar water heater operating on a clear summer day in the midland of Russia is 130‒150 L/m2. Storage tank volume and load schedule have a slight effect on solar water heater output. A thermal insulation layer of 35‒40 mm is sufficient to provide an efficient thermal insulation of the back and side walls. An experimental model layout representing a solar water heater prototype of a prime cost of 70‒90/(m2 receiving surface) has been developed for a manufacturing volume of no less than 5000 pieces per year.

  2. Herbert Easterly auxiliary truck heater. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The objective of this work was to continue the development of the Herbert Easterly heater apparatus for vehicles, such as semi-trailer tractors in order to fully establish its technical feasibility and provide the basis for its commercialization. This heater is auxiliary to the vehicle`s primary heating system. With the engine off it heats both the vehicle engine to a temperature at which it starts easily and the vehicle passenger compartment. Specifically, this heater is automatically ignitable, operates directly from the vehicle diesel fuel supply and preheats the vehicle engine fuel prior to combustion. During the course of this work ninemore » different versions of prototype heaters were designed, constructed and tested. All designs were based on the ideas and principles outlined in the Easterly patent. Each successive version incorporated design and fabrication improvements relative to the previous version. The final version, Prototype 9, utilized a multiple water jacket design to capture additional heat from the combustion gases prior to exhausting to the atmosphere. This final prototype exceeded the performance of a commercially available Webasto DBW-2010 using the same commercial burner as the one used in the Webasto unit. The time required to raise the heater fluid temperature by 120{degree}F was 23% less (20 minutes compared to 26 minutes) for Prototype 9 compared to the commercially available unit. In addition a prototype heat exchanger for preheating engine fuel was designed, fabricated and tested. It was also determined that the Prototype 9 auxiliary heater could operate at 85{degree}F for approximately 6 hours on a fully charged 12 volt marine battery rated to deliver 500 cold cranking amps.« less

  3. KSC-2010-5773

    NASA Image and Video Library

    2010-12-03

    CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station was aborted at T minus 1.1 seconds due to high engine chamber pressure. During the test, all nine Merlin engines, which use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust, are expected to fire at once. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell

  4. KSC-2010-5770

    NASA Image and Video Library

    2010-12-03

    CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station was aborted at T minus 1.1 seconds due to high engine chamber pressure. During the test, all nine Merlin engines, which use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust, are expected to fire at once. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell

  5. KSC-2010-5769

    NASA Image and Video Library

    2010-12-03

    CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station was aborted at T minus 1.1 seconds due to high engine chamber pressure. During the test, all nine Merlin engines, which use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust, are expected to fire at once. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Rusty Backer

  6. KSC-2010-5771

    NASA Image and Video Library

    2010-12-03

    CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station was aborted at T minus 1.1 seconds due to high engine chamber pressure. During the test, all nine Merlin engines, which use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust, are expected to fire at once. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell

  7. Fuel-flexible burner apparatus and method for fired heaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zink, Darton J.; Isaacs, Rex K.; Jamaluddin, A. S.

    A burner apparatus for a fired heating system and a method of burner operation. The burner provides stable operation when burning gas fuels having heating values ranging from low to high and accommodates sudden wide changes in the Wobbe value of the fuel delivered to the burner. The burner apparatus includes a plurality of exterior fuel ejectors and has an exterior notch which extends around the burner wall for receiving and combusting a portion of the gas fuel. At least a portion of the hot combustion product gas produced in the exterior notch is delivered through channels formed in themore » burner wall to the combustion area at the forward end of the burner. As the Wobbe value of the gas fuel decreases, one or more outer series of addition ejectors can be automatically activated as needed to maintain the amount of heat output desired.« less

  8. Evaluation of candidate Stirling engine heater tube alloys after 3500 hours exposure to high pressure doped hydrogen or helium

    NASA Technical Reports Server (NTRS)

    Misencik, J. A.; Titran, R. H.

    1984-01-01

    The heater head tubes of current prototype automotive Stirling engines are fabricated from alloy N-155, an alloy which contains 20 percent cobalt. Because the United States imports over 90 percent of the cobalt used in this country and resource supplies could not meet the demand imposed by automotive applications of cobalt in the heater head (tubes plus cylinders and regenerator housings), it is imperative that substitute alloys free of cobalt be identified. The research described herein focused on the heater head tubes. Sixteen alloys (15 potential substitutes plus the 20 percent Co N-155 alloy) were evaluated in the form of thin wall tubing in the NASA Lewis Research Center Stirling simulator materials diesel fuel fired test rigs. Tubes filled with either hydrogen doped with 1 percent CO2 or with helium at a gas pressure of 15 MPa and a temperature of 820 C were cyclic endurance tested for times up to 3500 hr. Results showed that two iron-nickel base superalloys, CG-27 and Pyromet 901 survived the 3500 hr endurance test. The remaining alloys failed by creep-rupture at times less than 3000 hr, however, several other alloys had superior lives to N-155. Results further showed that doping the hydrogen working fluid with 1 vol % CO2 is an effective means of reducing hydrogen permeability through all the alloy tubes investigated.

  9. Probe with integrated heater and thermocouple pack

    DOEpatents

    McCulloch, Reg W.; Dial, Ralph E.; Finnell, Wilber K. R.

    1990-01-01

    A probe for measuring heat includes an elongate rod fitted within a sheath, and a plurality of annular recesses are formed on the surface of the rod in a spaced-apart relationship to form annular chambers that are resistant to heat flow. A longitudinal bore extends axially into the rod and within the cylinders defined by the annular chambers, and an integrated heater and thermocouple pack is dimensioned to fit within the bore. In construction, the integrated pack includes a plurality of wires disposed in electrical insulation within a sheath and a heater cable. These wires include one common wire and a plurality of thermocuple wires. The common wire is constructed of one type of conductive material while the thermocouple wires are each constructed of two types of materials so that at least one thermocouple junction is formed therein. All of the wires extend the length of the integrated pack and are connected together at their ends. The thermocouple wires are constructed to form thermocouple junctions proximate to each annular chamber for producing electromotive forces corresponding to the temperature of the rod within the annular chambers relative to outside the chambers. In the preferred embodiment, each thermocouple wire forms two thermocouple junctions, one junction being disposed within an annular chamber and the second junction being disposed outside of, but proximate to, the same annular chamber. In one embodiment two thermocouple wires are configured to double the sensitivity of the probe in one region.

  10. Probe with integrated heater and thermocouple pack

    DOEpatents

    McCulloch, Reginald W.; Dial, Ralph E.; Finnell, Wilber K. R.

    1988-01-01

    A probe for measuring heat includes an elongate rod fitted within a sheath, and a plurality of annular recesses are formed on the surface of the rod in a spaced-apart relationship to form annular chambers that are resistant to heat flow. A longitudinal bore extends axially into the rod and within the cylinders defined by the annular chambers, and an integrated heater and thermocouple pack is dimensioned to fit within the bore. In construction, the integrated pack includes a plurality of wires disposed in electrical insulation within a sheath and a heater cable. These wires include one common wire and a plurality of thermocouple wires. The common wire is constructed of one type of conductive material while the thermocouple wires are each constructed of two types of materials so that at least one thermocouple junction is formed therein. All of the wires extend the length of the integrated pack and are connected together at their ends. The thermocouple wires are constructed to form thermocouple junctions proximate to each annular chamber for producing electromotive forces corresponding to the temperature of the rod within the annular chambers relative to outside the chambers. In the preferred embodiment, each thermocouple wire forms two thermocouple junctions, one junction being disposed within an annular chamber and the second junction being disposed outside of, but proximate to, the same annular chamber. In one embodiment two thermocouple wires are configured to double the sensitivity of the probe in one region.

  11. Fire Detector

    NASA Technical Reports Server (NTRS)

    1978-01-01

    An early warning fire detection sensor developed for NASA's Space Shuttle Orbiter is being evaluated as a possible hazard prevention system for mining operations. The incipient Fire Detector represents an advancement over commercially available smoke detectors in that it senses and signals the presence of a fire condition before the appearance of flame and smoke, offering an extra margin of safety.

  12. 40 CFR 65.149 - Boilers and process heaters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) A boiler or process heater with a design heat input capacity of 44 megawatts (150 million British... hazardous waste for which the owner or operator meets either of the following requirements: (A) The boiler...). If an owner or operator elects to use a boiler or process heater to replace an existing recovery...

  13. 40 CFR 65.149 - Boilers and process heaters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) A boiler or process heater with a design heat input capacity of 44 megawatts (150 million British... hazardous waste for which the owner or operator meets either of the following requirements: (A) The boiler...). If an owner or operator elects to use a boiler or process heater to replace an existing recovery...

  14. The efficacy of prophylactic antibiotics in the management of children with kerosene-associated pneumonitis: a double-blind randomised controlled trial.

    PubMed

    Balme, Kate H; Zar, Heather; Swift, Donne K; Mann, Michael D

    2015-01-01

    Hydrocarbons, especially kerosene (paraffin), are the most common agents causing childhood poisoning in low and middle income countries (LMICs). Aspiration of kerosene causes an inflammatory sterile chemical pneumonitis, which may increase susceptibility to secondary lower respiratory tract bacterial infection. This study aimed to assess the efficacy of prophylactic antibiotics in the management of kerosene-associated pneumonitis in children and to identify risk factors associated with severity or outcome. A double-blind placebo-controlled trial of prophylactic antibiotics in the management of kerosene-associated pneumonitis of children presenting to a referral hospital was performed from July 2010 to September 2011. Sequential children with a history of kerosene ingestion and mild respiratory illness were randomised to receive placebo or amoxicillin. Each child was followed-up at Day 3 and Day 5 post-ingestion. The primary outcome measure was the number of treatment failures in each group, defined as any child who deteriorated within this time, necessitating a change in treatment regimen. Secondary outcome measures were length of hospital stay and symptoms and signs at follow-up. Seventy-four patients were enrolled. Thirty-five (47%) received placebo and 39 (53%) active treatment. There was no significant difference in treatment failures between placebo (3/35, 9%; 95% CI, 3-22) and active (2/39, 5%; 95% CI, 1-17) groups (relative risk, 0.60; 95% CI, 0.11-3.37). The median length of hospital stay was identical (placebo 0.5 days; IQR, 0-1.0 and active 0.5 days; IQR, 0.5-1.0). Symptoms and signs at Days 3 and 5 post-ingestion were similar. The only significant risk factor for treatment failure was residence in formal housing. Clinical severity at presentation was similar for treatment successes and failures. Prophylactic antibiotics do not improve the outcome in children with mild respiratory illness after kerosene ingestion.

  15. Remote sensing techniques to assess active fire characteristics and post-fire effects

    Treesearch

    Leigh B. Lentile; Zachary A. Holden; Alistair M. S. Smith; Michael J. Falkowski; Andrew T. Hudak; Penelope Morgan; Sarah A. Lewis; Paul E. Gessler; Nate C. Benson

    2006-01-01

    Space and airborne sensors have been used to map area burned, assess characteristics of active fires, and characterize post-fire ecological effects. Confusion about fire intensity, fire severity, burn severity, and related terms can result in the potential misuse of the inferred information by land managers and remote sensing practitioners who require unambiguous...

  16. 24 CFR 3280.205 - Carpeting.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.205 Carpeting. Carpeting shall not be used in a space or compartment designed to contain only a furnace and/or water heater...

  17. Forced convection in vertical Bridgman configuration with the submerged heater

    NASA Astrophysics Data System (ADS)

    Meyer, S.; Ostrogorsky, A. G.

    1997-02-01

    Ga-doped Ge single crystals were grown in vertical Bridgman configuration, using the submerged heater method (SHM). When used without rotation, the submerged heater drastically reduces convection at the solid-liquid interface. When the submerged heater is set in to rotation or oscillatory rotation, it acts as a centrifugal viscous pump, inducing forced convection (radial-inward flow) along the interface. The flow produced by a rotation and oscillatory rotation of the submerged heater was visualized using a 1 : 1 scale model. The vigorous mixing produced by the oscillatory rotation creates a nearly perfectly stirred melt, and yields a uniform lateral distribution of the dopant. The crystals were free of unintentionally produced striae.

  18. Evaluation of Cathode Heater Assembly for 42 GHz, 200 kW Gyrotron

    NASA Astrophysics Data System (ADS)

    Sharma, S. K.; Singh, Narendra Kumar; Singh, Udaybir; Khatun, Hasina; Kumar, Nitin; Alaria, M. K.; Raju, R. S.; Jain, P. K.; Sinha, A. K.

    2014-09-01

    In this paper, the evaluation of cathode-heater assembly of magnetron injection gun (MIG) for 42 GHz, 200 kW gyrotron is presented. The cathode-heater assembly is purchased from M/S SEMICON.The cathode-heater assembly is experimentally studied in three different conditions; in a belljar system, during vacuum processing of MIG and during MIG testing to ensure the required rise of cathode surface temperature for pre-set heater power.

  19. Antimisting kerosene atomization and flammability

    NASA Technical Reports Server (NTRS)

    Fleeter, R.; Petersen, R. A.; Toaz, R. D.; Jakub, A.; Sarohia, V.

    1982-01-01

    Various parameters found to affect the flammability of antimisting kerosene (Jet A + polymer additive) are investigated. Digital image processing was integrated into a technique for measurement of fuel spray characteristics. This technique was developed to avoid many of the error sources inherent to other spray assessment techniques and was applied to the study of engine fuel nozzle atomization performance with Jet A and antimisting fuel. Aircraft accident fuel spill and ignition dynamics were modeled in a steady state simulator allowing flammability to be measured as a function of airspeed, fuel flow rate, fuel jet Reynolds number and polymer concentration. The digital imaging technique was employed to measure spray characteristics in this simulation and these results were related to flammability test results. Scaling relationships were investigated through correlation of experimental results with characteristic dimensions spanning more than two orders of magnitude.

  20. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maguire, J.; Burch, J.; Merrigan, T.

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently reemerged on the U.S. market. These units have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine what actual in use energy consumption of a HPWH may be in different regions of the U.S., annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the U.S. The simulations included a benchmark home to takemore » into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.« less

  1. Diesel particulate filter with zoned resistive heater

    DOEpatents

    Gonze, Eugene V [Pinckney, MI

    2011-03-08

    A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

  2. Haem peroxidase activity in Daphnia magna: a biomarker for sub-lethal toxicity assessments of kerosene-contaminated groundwater.

    PubMed

    Connon, Richard; Dewhurst, Rachel E; Crane, Mark; Callaghan, Amanda

    2003-10-01

    A novel biomarker was developed in Daphnia magna to detect organic pollution in groundwater. The haem peroxidase assay, which is an indirect means of measuring oxidase activity, was particularly sensitive to kerosene contamination. Exposure to sub-lethal concentrations of kerosene-contaminated groundwater resulted in a haem peroxidase activity increase by dose with a two-fold activity peak at 25%. Reproduction in D. magna remained unimpaired when exposed to concentrations below 25% for 21 days, and a decline in fecundity was only observed at concentrations above the peak in enzyme activity. The measurement of haem peroxidase activity in D. magna detected sublethal effects of kerosene in just 24 h, whilst offering information on the health status of the organisms. The biomarker may be useful in determining concentrations above which detrimental effects would occur from long-term exposure for fuel hydrocarbons. Moreover, this novel assay detects exposure to chemicals in samples that would normally be classified as non-toxic by acute toxicity tests.

  3. Fire protection for launch facilities using machine vision fire detection

    NASA Astrophysics Data System (ADS)

    Schwartz, Douglas B.

    1993-02-01

    Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

  4. Fire protection for launch facilities using machine vision fire detection

    NASA Technical Reports Server (NTRS)

    Schwartz, Douglas B.

    1993-01-01

    Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

  5. Protection heater design validation for the LARP magnets using thermal imaging

    DOE PAGES

    Marchevsky, M.; Turqueti, M.; Cheng, D. W.; ...

    2016-03-16

    Protection heaters are essential elements of a quench protection scheme for high-field accelerator magnets. Various heater designs fabricated by LARP and CERN have been already tested in the LARP high-field quadrupole HQ and presently being built into the coils of the high-field quadrupole MQXF. In order to compare the heat flow characteristics and thermal diffusion timescales of different heater designs, we powered heaters of two different geometries in ambient conditions and imaged the resulting thermal distributions using a high-sensitivity thermal video camera. We observed a peculiar spatial periodicity in the temperature distribution maps potentially linked to the structure of themore » underlying cable. Two-dimensional numerical simulation of heat diffusion and spatial heat distribution have been conducted, and the results of simulation and experiment have been compared. Imaging revealed hot spots due to a current concentration around high curvature points of heater strip of varying cross sections and visualized thermal effects of various interlayer structural defects. Furthermore, thermal imaging can become a future quality control tool for the MQXF coil heaters.« less

  6. Stirling Space Engine Program. Volume 2; Appendixes A, B, C and D

    NASA Technical Reports Server (NTRS)

    Dhar, Manmohan

    1999-01-01

    The objective of this program was to develop the technology necessary for operating Stirling power converters in a space environment and to demonstrate this technology in full-scale engine tests. Volume 2 of the report includes the following appendices: Appendix A: Heater Head Development (Starfish Heater Head Program, 1/10th Segment and Full-Scale Heat Pipes, and Sodium Filling and Processing); Appendix B: Component Test Power Converter (CTPC) Component Development (High-temperature Organic Materials, Heat Exchanger Fabrication, Beryllium Issues, Sodium Issues, Wear Couple Tests, Pressure Boundary Penetrations, Heating System Heaters, and Cooler Flow Test); Appendix C: Udimet Testing (Selection of the Reference Material for the Space Stirling Engine Heater Head, Udimet 720LI Creep Test Result Update, Final Summary of Space Stirling Endurance Engine Udimet 720L1 Fatigue Testing Results, Udimet 720l1 Weld Development Summary, and Udimet 720L1 Creep Test Final Results Summary), and Appendix D: CTPC Component Development Photos.

  7. RP1 (KEROSENE) STORAGE TANKS ON HILLSIDE EAST OF TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    RP1 (KEROSENE) STORAGE TANKS ON HILLSIDE EAST OF TEST STAND 1-B. THIS TANK FARM SERVES BOTH TEST STANDS 1-A AND 1-B - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Combined Fuel Storage Tank Farm, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  8. Advanced fire observation by the Intelligent Infrared Sensor prototype FOCUS on the International Space Station

    NASA Astrophysics Data System (ADS)

    Oertel, D.; Haschberger, P.; Tank, V.; Lanzl, F.; Zhukov, B.; Jahn, H.; Briess, K.; Lorenz, E.; Roeser, H.-P.; Ginati, A.; Tobehn, C.; Schulte in den Bäumen, J.; Christmann, U.

    1999-01-01

    Current and planned operational space-borne Earth observation systems provide spatially, radiometrically or temporally crude data for the detection and monitoring of high temperature phenomena on the surface of our planet. High Temperature Events (HTE) very often cause environmental disasters. Such HTE are forest and savannah fires, fires of open coal mines, volcanic activities and others (e.g. fires of oil wells, pipelines etc.). A simultaneous co-registration of a combination of infrared (IR) and visible (VIS) channels is the key for a reliable autonomous on-board detection of High Temperature Events (HTE) on Earth surface, such as vegetation fires and volcano eruptions. This is the main feature of the FOCUS experiment. Furthermore there are ecology-oriented objectives of the FOCUS experiment mainly related to spectrometric/imaging remote inspection and parameter extraction of selected HTEs, and to the assessment of some ecological consequences of HTEs, such as aerosol and gas emission. Based on own experimental work and supported by Co-Investigators from Italy, Greece, France, Spain, Russia and Germany, DLR proposed in 1997 to use the International Space Station (ISS) in its early utilization phase as a platform and test-bed for an Intelligent Infrared Sensor prototype FOCUS of a future Environmental Disaster Recognition Satellite System. FOCUS is considered by ESA as an important mission combining a number of proven technologies and observation techniques to provide the scientific and operational user community with key data for the classification and monitoring of forest fires. FOCUS was selected as one of five European ``Groupings'' to be flown as an externally mounted payload during the early utilisation phase of the ISS. The FOCUS Phase A Study will be performed by OHB-System, DLR and Zeiss from September 1998 until May 1999.

  9. Around Marshall

    NASA Image and Video Library

    1993-09-01

    Marshall Space Flight Center's F-1 Engine Test Stand is shown in this picture. Constructed in 1963, the test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. The foundation of the stand is keyed into the bedrock approximately 40 feet below grade.

  10. Fire safety applications for spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Olson, Sandra L.

    1989-01-01

    Fire safety for spacecraft is reviewed by first describing current practices, many of which are adapted directly from aircraft. Then, current analyses and experimental knowledge in low-gravity combustion, with implications for fire safety are discussed. In orbiting spacecraft, the detection and suppression of flames are strongly affected by the large reduction in buoyant flows under low gravity. Generally, combustion intensity is reduced in low gravity. There are some notable exceptions, however, one example being the strong enhancement of flames by low-velocity ventilation flows in space. Finally, the future requirements in fire safety, particularly the needs of long-duration space stations in fire prevention, detection, extinguishment, and atmospheric control are examined. The goal of spacecraft fire-safety investigations is the establishment of trade-offs that promote maximum safety without hampering the useful human and scientific activities in space.

  11. Increased PCDD/F formation in the bottom ash from fires of CCA-treated wood.

    PubMed

    Tame, N W; Dlugogorski, B Z; Kennedy, E M

    2003-03-01

    Bottom ash that was the result of the combustion of chromated copper arsenate (CCA) treated wood under controlled fire conditions showed an increase of several orders of magnitude in the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), compared to that of untreated timber. Wood that has been pressure treated with CCA contains copper (II), which is known to catalyse the so-called de novo formation of PCDD/Fs. Comparable levels of PCDD/Fs would be expected in residual ash from burning CCA-treated wood in backyard fires, stoves and wood heaters, as a consequence of similar combustion conditions.

  12. Nonlinear Gravitational and Radiation Aspects in Nanoliquid with Exponential Space Dependent Heat Source and Variable Viscosity

    NASA Astrophysics Data System (ADS)

    Gireesha, B. J.; Kumar, P. B. Sampath; Mahanthesh, B.; Shehzad, S. A.; Abbasi, F. M.

    2018-05-01

    The nonlinear convective flow of kerosene-Alumina nanoliquid subjected to an exponential space dependent heat source and temperature dependent viscosity is investigated here. This study is focuses on augmentation of heat transport rate in liquid propellant rocket engine. The kerosene-Alumina nanoliquid is considered as the regenerative coolant. Aspects of radiation and viscous dissipation are also covered. Relevant nonlinear system is solved numerically via RK based shooting scheme. Diverse flow fields are computed and examined for distinct governing variables. We figured out that the nanoliquid's temperature increased due to space dependent heat source and radiation aspects. The heat transfer rate is higher in case of changeable viscosity than constant viscosity.

  13. Nonlinear Gravitational and Radiation Aspects in Nanoliquid with Exponential Space Dependent Heat Source and Variable Viscosity

    NASA Astrophysics Data System (ADS)

    Gireesha, B. J.; Kumar, P. B. Sampath; Mahanthesh, B.; Shehzad, S. A.; Abbasi, F. M.

    2018-02-01

    The nonlinear convective flow of kerosene-Alumina nanoliquid subjected to an exponential space dependent heat source and temperature dependent viscosity is investigated here. This study is focuses on augmentation of heat transport rate in liquid propellant rocket engine. The kerosene-Alumina nanoliquid is considered as the regenerative coolant. Aspects of radiation and viscous dissipation are also covered. Relevant nonlinear system is solved numerically via RK based shooting scheme. Diverse flow fields are computed and examined for distinct governing variables. We figured out that the nanoliquid's temperature increased due to space dependent heat source and radiation aspects. The heat transfer rate is higher in case of changeable viscosity than constant viscosity.

  14. Determination of Ignitable Liquids in Fire Debris: Direct Analysis by Electronic Nose

    PubMed Central

    Ferreiro-González, Marta; Barbero, Gerardo F.; Palma, Miguel; Ayuso, Jesús; Álvarez, José A.; Barroso, Carmelo G.

    2016-01-01

    Arsonists usually use an accelerant in order to start or accelerate a fire. The most widely used analytical method to determine the presence of such accelerants consists of a pre-concentration step of the ignitable liquid residues followed by chromatographic analysis. A rapid analytical method based on headspace-mass spectrometry electronic nose (E-Nose) has been developed for the analysis of Ignitable Liquid Residues (ILRs). The working conditions for the E-Nose analytical procedure were optimized by studying different fire debris samples. The optimized experimental variables were related to headspace generation, specifically, incubation temperature and incubation time. The optimal conditions were 115 °C and 10 min for these two parameters. Chemometric tools such as hierarchical cluster analysis (HCA) and linear discriminant analysis (LDA) were applied to the MS data (45–200 m/z) to establish the most suitable spectroscopic signals for the discrimination of several ignitable liquids. The optimized method was applied to a set of fire debris samples. In order to simulate post-burn samples several ignitable liquids (gasoline, diesel, citronella, kerosene, paraffin) were used to ignite different substrates (wood, cotton, cork, paper and paperboard). A full discrimination was obtained on using discriminant analysis. This method reported here can be considered as a green technique for fire debris analyses. PMID:27187407

  15. Improved Controllers For Heaters In Toxic-Gas Combustors

    NASA Technical Reports Server (NTRS)

    Wishard, James; Lamb, James; Fortier, Edward; Velasquez, Hugo; Waltman, Doug

    1995-01-01

    Commercial electronic proportional controllers installed in place of mechanical power controllers for electric heaters in toxic-gas combustors at NASA's Jet Propulsion Laboratory. Designed to maintain temperature of heater at preset value by turning power fully on or fully off when temperature falls below or rises above that value, respectively. Solid-state power controllers overcome deficiencies of mechanical power controllers.

  16. Landscape scale vegetation-type conversion and fire hazard in the San Francisco bay area open spaces

    USGS Publications Warehouse

    Russell, W.H.; McBride, J.R.

    2003-01-01

    Successional pressures resulting from fire suppression and reduced grazing have resulted in vegetation-type conversion in the open spaces surrounding the urbanized areas of the San Francisco bay area. Coverage of various vegetation types were sampled on seven sites using a chronosequence of remote images in order to measure change over time. Results suggest a significant conversion of grassland to shrubland dominated by Baccharis pilularison five of the seven sites sampled. An increase in Pseudotsuga menziesii coverage was also measured on the sites where it was present. Increases fuel and fire hazard were determined through field sampling and use of the FARSITE fire area simulator. A significant increase in biomass resulting from succession of grass-dominated to shrub-dominated communities was evident. In addition, results from the FARSITE simulations indicated significantly higher fire-line intensity, and flame length associated with shrublands over all other vegetation types sampled. These results indicate that the replacement of grass dominated with shrub-dominated landscapes has increased the probability of high intensity fires. ?? 2003 Elsevier Science B.V. All rights reserved.

  17. Household fuels, low birth weight, and neonatal death in India: the separate impacts of biomass, kerosene, and coal.

    PubMed

    Epstein, M B; Bates, M N; Arora, N K; Balakrishnan, K; Jack, D W; Smith, K R

    2013-08-01

    We examined the impact of maternal use of different household cooking fuels in India on low birth weight (LBW<2500g), and neonatal mortality (death within 28 days of birth). Using cross-sectional data from India's National Family Health Survey (NFHS-3), we separately analyzed the prevalence of these two outcomes in households utilizing three types of high-pollution fuels for cooking - biomass, coal, and kerosene - using low-pollution fuels (gas and biogas) as the comparison "control" group. Taking socioeconomic and child-specific factors into account, we employed logistic regression to examine the impact of fuel use on fetal and infant health. The results indicate that household use of high-pollution fuels is significantly associated with increased odds of LBW and neonatal death. Compared to households using cleaner fuels (in which the mean birth weight is 2901g), the primary use of coal, kerosene, and biomass fuels is associated with significant decreases in mean birth weight (of -110g for coal, -107g for kerosene, and -78g for biomass). Kerosene and biomass fuel use are also associated with increased risk of LBW (p<0.05). Results suggest that increased risk of neonatal death is strongly associated with household use of coal (OR 18.54; 95% CI: 6.31-54.45), and perhaps with kerosene (OR 2.30; 95% CI: 0.95-5.55). Biomass is associated with increased risk of neonatal death among infants born to women with no more than primary education (OR 7.56; 95% CI: 2.40-23.80). These results are consistent with a growing literature showing health impacts of household air pollution from these fuels. Copyright © 2012 Elsevier GmbH. All rights reserved.

  18. Fire weather and likelihood: characterizing climate space for fire occurrence and extent in Puerto Rico

    Treesearch

    Ashley E. Van Beusekom; William A. Gould; A. Carolina Monmany; Azad Henareh Khalyani; Maya Quiñones; Stephen J. Fain; Maria José Andrade-Núñez; Grizelle González

    2018-01-01

    Abstract Assessing the relationships between weather patterns and the likelihood of fire occurrence in the Caribbean has not been as central to climate change research as in temperate regions, due in part to the smaller extent of individual fires. However, the cumulative effect of small frequent fires can shape large landscapes, and fire-prone ecosystems are abundant...

  19. Assessing the home fire safety of urban older adults: a case study.

    PubMed

    Twyman, Stephanie; Fahey, Erin; Lehna, Carlee

    2014-01-01

    Older adults are at a higher risk for fatal house fire injury due to decreased mobility, chronic illness, and lack of smoke alarms. The purpose of this illustrative case study is to describe the home fire safety (HFS) status of an urban older adult who participated in a large study funded by the Federal Emergency Management Agency (FEMA). During a home visit with the participant, HFS data were collected from documents, observation, physical artifacts, reflective logs, and interviews. Numerous HFS hazards were identified including non-working smoke alarms, inadequate number and inappropriate placement of smoke alarms, lack of carbon monoxide (CO) alarms, inability to identify a home fire escape plan, hot water heater temperature set too high, and cooking hazards. Identification of HFS risk factors will assist in the development of educational materials that can be tailored to the older adult population to decrease their risk of fire-related injuries and death.

  20. Development of the International Space Station (ISS) Fine Water Mist (FWM) Portable Fire Extinguisher ICES Abstract

    NASA Technical Reports Server (NTRS)

    Clements, Anna L.; Carlile, Christie; Graf, John; Young, Gina

    2011-01-01

    NASA is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. FWM extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE. In addition, the NASA ISS specific fire standards will be described which were developed to establish acceptable extinguisher performance. The paper will also discuss the flight hardware design. The fin e water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface have been under development for several years. They have gone through several design iterations, and have been part of more than 400 fire challenge and spray characterizations. The