Sample records for key comparison bilateral

  1. KEY COMPARISON: Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Kurupakorn, C.; Fletcher, N.; Stock, M.

    2010-01-01

    This report describes the results obtained from a NIMT (Thailand)-BIPM bilateral comparison of 10 kΩ resistance standards in 2009. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMIT and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was smaller than the uncertainty arising from the calibrations. The mean difference between the NIMT and the BIPM calibrations was found to be significantly larger than the expanded uncertainty (k = 2) of the comparison. However, this exercise allowed previously undetected sources of errors to be detected in the NIMT facility. A new bilateral comparison can be organized as soon as these problems are fixed. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Bilateral key comparison on luminous flux COOMET.PR-K4.1. final report

    NASA Astrophysics Data System (ADS)

    Huriev, M.; Khlevnoy, B.; Tolstykh, G.; Ivashin, E.; Gorchkova, T.

    2017-01-01

    This report describes an international bilateral key comparison on luminous flux of tungsten lamps between the National Scientific Centre 'Institute of Metrology' (NSC 'IM', Ukraine) and All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI, Russia). The comparison is intended to determine the Degrees of Equivalence (DoE) for NSC 'IM' and the associated expanded uncertainty. VNIIOFI acts as a laboratory, providing the link to the comparison CCPR-K4. The comparison used a set of tungsten incandescent lamps as a transfer standard with a luminous flux of approximately 3800 lm. The determined DoE of NSC 'IM' is -0.94% with an expanded uncertainty (k = 2) of 1.05%. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 1 Ω resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Two BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The mean difference between the NMLI and the BIPM calibrations was found to be just within the expanded uncertainty (k = 2) of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. KEY COMPARISON: Final report on bilateral comparison CCEM.RF-K9.1: Thermal noise standards at 12.4 GHz, 13.5 GHz, 15 GHz and 17.5 GHz

    NASA Astrophysics Data System (ADS)

    Allal, Djamel

    2009-01-01

    A bilateral comparison subsequent to key comparison CCEM.RF-K9 was decided between VNIIFTRI and PTB. It was registered into the BIPM KCDB under the identifier CCEM.RF-K9.1. The results of this comparison were gathered by the pilot laboratory of comparison CCEM.RF-K9, the LNE, and a very good agreement was found between the two participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 10 kΩ resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NMLI and the BIPM calibrations were found to be in agreement, with a mean difference smaller than the standard uncertainty of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. KEY COMPARISON: CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    NASA Astrophysics Data System (ADS)

    Hill, K. D.; Steele, A. G.; Dedikov, Y. A.; Shkraba, V. T.

    2005-01-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 Ω capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L&N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions

  7. KEY COMPARISON: Final report on Key Comparison APMP.SIM.M.P-K1c: Bilateral comparison between NIST (USA) and NPLI (India) in the pneumatic pressure region 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Driver, R. Gregory; Olson, Douglas A.; Dilawar, Nita; Bandyopadhyay, A. K.

    2007-01-01

    We report the results of a bilateral comparison of pressure measurement between NIST and NPLI using a piston gauge transfer standard (TS), designated as NPLI-4, over the range of nominal applied pressure 0.4 MPa to 4.0 MPa. This TS was cross-floated against the laboratory secondary standard designated as PG13 at NIST, USA and against NPLI-8 at NPLI, India. The nominal pressure points of the bilateral comparison were (0.4, 0.8, 1.2, 1.6, 2.0, 2.4, 2.8, 3.2, 3.6 and 4.0) MPa, respectively. The comparison was performed in both the institutes in identical pressure cycles in increasing pressures. The comparison data were analysed in terms of the effective area [Ap (mm2)] as a function pressure [p (MPa)] of the TS at the above-mentioned pressures. We have also estimated the zero-pressure effective area [A0 (mm2)] and the pressure distortion coefficient [λ (MPa-1)] of the transfer standard. The consistency of the results at every pressure in the range indicates that the laboratory standards used in this comparison are compatible, uniform and can be considered traceable to each other. Finally, the degree of equivalence between NPLI and NIST is 11.4 × 10-6 or better, which is always less than the relative standard uncertainty of the difference (33.6 × 10-6). Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Power, Oliver

    2017-01-01

    This report presents the results of a bilateral comparison of capacitance at 100 pF between the NSAI-NML (Ireland) and the BIPM carried out in 2016. This comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b in which the BIPM is the pilot laboratory. Two 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring rms voltage of 15 V. The results from the NSAI-NML and the BIPM were found to be in relatively good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.85 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. SUPPLEMENTARY COMPARISON: Final report on APMP.PR-S1.1: Bilateral comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Huang, Xuebo

    2009-01-01

    In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Bilateral key comparison CCM.P-K3.1 for absolute pressure measurements from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Fedchak, J. A.; Bock, Th; Jousten, K.

    2014-01-01

    This report describes the bilateral key comparison CCM.P-K3.1 between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt (PTB) for absolute pressure in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. This comparison was a follow-up to the comparison CCM.P-K3. Two ionization gauges and two spinning rotor gauges (SRGs) were used as the transfer standards for the comparison. The SRGs were used to compare the standards at a pressure of 9 × 10-4 Pa and to normalize the ionization gauge readings. The two ionization gauges were used to compare the standards in the pressure range of from 3 × 10-6 Pa to 3 × 10-4 Pa. Both laboratories used dynamic expansion chambers as standards in the comparison. The two labs showed excellent agreement with each other and with the CCM.P-K3 key comparison reference value (KCRV) over the entire range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Report on the bilateral comparison between BIM (Bulgaria) and VSL (The Netherlands)

    NASA Astrophysics Data System (ADS)

    Dekker, Paul; Kunova, Angela; Dierikx, Erik

    2017-01-01

    A bilateral comparison has been organized between VSL, The Netherlands and BIM, Bulgaria in the field of spectral regular transmittance measurements. This comparison is registered as EURAMET project nr. 1073 and EURAMET.PR-K6.2 in the BIPM key comparison database. The aim of the comparison is to demonstrate the improvement of calibration measurement capabilities of BIM in this working field. If this comparison is successful, i.e. the results support the claimed improvement in uncertainties, the improved CMC's for BIM will be included in Appendix C of the CIPM mutual recognition arrangement (MRA). The results of this comparison are linked to key comparison CCPR K6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.66 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A—B—A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 2.5 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Report on NIM-NMC bilateral comparison: SPRT calibration comparison from -190°C to 420°C

    NASA Astrophysics Data System (ADS)

    Sun, Jianping; Ye, Shaochun; Wang, Li; Zhang, Jintao; Kho, Haoyuan

    2016-01-01

    A bilateral comparison of local realization of the International temperature scale of 1990 (ITS-90) between National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from -190°C to 420°C. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key comparison 3 (CCT-K3) and facilitate the NMC's Calibration and measurement capabilities (CMCs) submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme (APMP) in 2009, and registered in the Key Comparison Database (KCDB) in 2010 as CCT-K3.2. NMC supplied two 25 Ω fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn and Zn fixed points, while the other one was used at the Ar and Hg fixed point. NMC measured them before and after NIM measurement. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 Average Reference Value (ARV) using NIM as a link are reported with expanded uncertainties at each measured fixed point. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the SMD (Belgium) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, Benjamin; Fletcher, Nick; Vlad, Dana

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the SMD (Belgium) and the BIPM carried out in 2017. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the SMD, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13.b (for 10 kΩ). The results from the SMD and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.080 × 10-6 for 1 Ω and 0.068 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIMT (Thailand) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Khumthukthit, N.; Jassadajin, C.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NIMT (Thailand) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NIMT and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.20 × 10-6 for 1 Ω and 0.74 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the CMI (Czech Republic) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Kučera, J.; Chrobok, P.; Vo&jacute; čko&vacute; , L.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the CMI (Czech Republic) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the CMI and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.046 × 10-6 for 1 Ω and 0.034 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Power, O.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.16 × 10-6 for 1 Ω and 0.42 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the BIM (Bulgaria) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Tenev, A.; Hadzhistoykova, R.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the BIM (Bulgaria) and the BIPM carried out in 2013. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.30 × 10-6 at 10 kΩ and in reasonable agreement for 1 Ω with a relative difference of -0.18 × 10-6 with a relative expanded uncertainty of 0.17 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NIS (Egypt) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Helmy, M.; Raouf, A.; Hamed, Heba A. M.; Eliwa Gad, A.

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NIS (Egypt) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NIS, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NIS and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of about 0.72 × 10-6 at 10 pF and about 0.65 × 10-6 at 100 pF. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NMISA (South Africa) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Khoza, Michael

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NMISA (South Africa) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NMISA, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NMISA and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of maximum value 0.33 × 10-6 at 10 pF and 0.24 × 10-6 at 100 pF (and 1000 Hz in both cases). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. KEY COMPARISON: Report of the spectral irradiance comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

    NASA Astrophysics Data System (ADS)

    Ojanen, M.; Shpak, M.; Kärhä, P.; Leecharoen, R.; Ikonen, E.

    2009-01-01

    A bilateral comparison of the spectral irradiance scales between MIKES (Finland) and NIMT (Thailand) was carried out at 22 wavelengths between 290 nm and 900 nm. MIKES acted as the pilot and link to the results of the key comparison CCPR-K1.a. The spectral irradiance values measured by NIMT generally agree with the key comparison reference value within the expanded uncertainty. The only exceptions are results at wavelengths 300 nm, 450 nm and 500 nm, where the ratios between the degree of equivalence (DoE) and the expanded uncertainty of DoE (k = 2) are 1.0, 1.4 and 1.2, respectively. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. SUPPLEMENTARY COMPARISON: Report of the bilateral comparison of the calibrations of hydrometers for liquid density determination between CENAM-Mexico and INRIM-Italy: SIM.M.D-S1

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Lorefice, Salvatore

    2009-01-01

    Hydrometers are instruments usually made of glass which are widely used for different levels of precision to measure liquid density and related quantities to control different products and processes. This bilateral comparison on the calibration of hydrometers shows that results reported by CENAM-Mexico and INRIM-Italy are consistent within the claimed uncertainty in the range of 800 kg/m3 to 1200 kg/m3. This bilateral comparison is intended to link the two regional comparisons SIM.M.D-K4 and EURAMET.D-K4. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. KEY COMPARISON: Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

    NASA Astrophysics Data System (ADS)

    Hung, Chen-Chuan; Jian, Wu; Changpan, Tawat

    2009-01-01

    This report describes the key comparison APMP.M.P-K6.1 among the three national metrology institutes, Center for Measurement Standards-ITRI (CMS-ITRI, Taiwan), SPRING Singapore and National Institute of Metrology (NIMT), in the pressure range from 20 kPa to 105 kPa in gas media and gauge mode executed during the period April 2003 to April 2004. This comparison was conducted by CMS-ITRI and was based on the calibration procedure of APMP pneumatic pressure comparison APMP.M.P-K6. We intended to link to the CCM.P-K6 key comparison through the APMP.M.P-K6 key comparison by using the proposed linkage method in the APMP.M.P-K6 key comparison to determine a linking factor that can transform the quantities measured in the APMP.M.P-K6.1 key comparison. All three participating institutes used pneumatic piston gauges as their pressure standards. The Ruska 2465 gas-operated piston-cylinder assembly TL-1409 used as transfer standard offered by CMS-ITRI was calibrated three times by the pilot institute during the comparison period and showed that it was very stable after evaluation. The comparison was conducted on the basis of cross-float experiments to determine the effective area of transfer standards from the national standards of three institutes. The comparison results (as shown in Table 6) were equivalent to the CCM.P-K6 comparison and the relative bilateral degrees of equivalence between two laboratories were smaller than 39.7 × 10-6 from 20 kPa to 105 kPa. These results showed all participating institutes measuring the same quantity in the whole pressure range lay within their expanded uncertainty with confidence level 95%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. SUPPLEMENTARY COMPARISON: APMP.EM-S6: Bilateral supplementary comparison of resistance

    NASA Astrophysics Data System (ADS)

    Charoensook, Ajchara; Jassadajin, Chaiwat; Chen, Henry; Ricketts, Brian

    2004-01-01

    A bilateral supplementary comparison of resistance, APMP.EM-S6, was conducted between the National Institute of Metrology Thailand (NIMT) and the CSIRO National Measurement Laboratory of Australia (NML). The comparison covered seven values of resistance, 0.1 Ω, 1 Ω, 100 Ω, 10 kΩ, 100 kΩ, 1 MΩ and 100 MΩ. The 0.1 Ω resistor was a YEW type 2792, the 100 MΩ resistor was an IET type SRC and the other five resistors were Fluke type 742A. The resistors were supplied by NIMT, and NML was the pilot laboratory for the comparison. The measurements for the comparison were made between December 2003 and April 2004. The resistors were measured on three separate occasions by NIMT and between each of these occasions the resistors were sent to NML for measurement. The resistors of nominal values 0.1 Ω, 1 Ω, 100 Ω and 10 kΩ were measured as four-terminal resistors while the 100 kΩ, 1 MΩ and 100 MΩ resistors were measured as two-terminal resistors. The quantity En (the absolute value of the difference between the values obtained at the two laboratories divided by the root sum square of the expanded uncertainties of the two values) was calculated for each resistance value used in the comparison. In all cases En was less than 0.5. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the Mutual Recognition Arrangement (MRA).

  8. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Comparison is key.

    PubMed

    Stone, Mark H; Stenner, A Jackson

    2014-01-01

    Several concepts from Georg Rasch's last papers are discussed. The key one is comparison because Rasch considered the method of comparison fundamental to science. From the role of comparison stems scientific inference made operational by a properly developed frame of reference producing specific objectivity. The exact specifications Rasch outlined for making comparisons are explicated from quotes, and the role of causality derived from making comparisons is also examined. Understanding causality has implications for what can and cannot be produced via Rasch measurement. His simple examples were instructive, but the implications are far reaching upon first establishing the key role of comparison.

  10. Bilateral Comparison Between NIM and NMC Over the Temperature Range from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Sun, Jianping; Ye, Shaochun; Kho, Haoyuan; Zhang, Jintao; Wang, Li

    2015-08-01

    A bilateral comparison of local realization of the International Temperature Scale of 1990 between the National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from 83.8058 K to 692.677 K. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin, and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key Comparison 3 (CCT-K3) and facilitate the NMC's calibration and measurement capabilities submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme in 2009, and registered in the Key Comparison Database in 2010 as CCT-K3.2. NMC supplied two fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn, and Zn fixed points, while the other one was used at the Ar and Hg fixed points. NMC measured them before and after NIM measured them. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 average reference value using NIM as a link are reported with expanded uncertainties at each measured fixed point.

  11. AC Power at Power Frequencies: Bilateral comparison between SASO NMCC and TÜBİTAK UME

    NASA Astrophysics Data System (ADS)

    Çaycı, Hüseyin; Yılmaz, Özlem; AlRobaish, Abdullah M.; AlAnazi, Shafi S.; AlAyali, Ahmed R.; AlRumie, Rashed A.

    2018-01-01

    A supplementary bilateral comparison measurement on AC Power at 50/60 Hz between SASO NMCC (GULFMET) and TÜBİTAK UME (EURAMET) was performed with the primary power standards of each partner. Measurement methods and setups which are very similar of the participants, measurement results, calculation of differences in the results, evaluation of uncertainties are given within this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. CCM key comparison CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.; Lenard, E.; Lee, Y. J.; Lee, W. G.; Madec, T.; Meury, P. A.; Caceres, J.; Santos, C.; Vamossy, C.; Man, J.; Fen, K.; Toda, K.; Wright, J.; Bettin, H.; Toth, H.

    2016-01-01

    This report presents the comparison philosophy, methodology, analysis and the results of the designed CCM.D-K4 key comparison that covered the calibration of high resolution hydrometers for liquid and alcoholometers in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20°C. The main purpose of this comparison was not only to evaluate the degree of equivalence in the calibration of high accuracy hydrometers between NMI participants, but also to link, were it is possible, the results of previous comparisons to Key Comparison Reference Values (KCRVs) of CCM.D-K4. Eleven NMI laboratories took part in the CCM.D-K4 divided in two groups (petals). With the CCM.D-K4 purpose, two similar sets consisting of three hydrometers for liquid density determinations and an alcoholometer were circulated to the NMI participants as a travelling standard in the time interval from January 2011 to April 2012. Twelve Key Comparison Reference Values (KCRVs) for each petal have been obtained at the density values related to the tested density marks of the transfer standards by the results of participants. The KCRVs and corresponding uncertainties were calculated by the weighted mean in the case of consistent results, otherwise the median was used. The degree of equivalence (DoE) with respect to the corresponding KCRV was determined for each participant and, in this particular comparison, the Weighted Least Squares (WLS) method was used to link the individual DoE of each participant by a continuous function. Significant drift of the transfer standards was not detected. This report also gives instructions on calculating pair-wise degrees of equivalence, with the addition of any information on correlations that may be necessary to estimate more accurately as well as the procedure for linking international comparisons to the CCM.D-K4. Finally an example of linkage to the CCM.D-K4 is given by dealing with the results of the bilateral comparison between INRiM and NMIA, which was

  13. Final report on bilateral comparison SIM.EM-S9.b: Comparison of resistance standards at 1 Ω and 10 kΩ between INIMET (Cuba) and INTI (Argentina), March to October 2012

    NASA Astrophysics Data System (ADS)

    Tonina, A.; Currás, M.; Navarro, M.

    2014-01-01

    The CIPM MRA states that its technical basis is a set of results obtained in a course of time through key comparisons carried out by the Consultative Committees of the CIPM, the BIPM and the Regional Metrology Organizations (RMOs). As part of this process, INTI (Argentina) has participated in several key and supplementary comparisons. By means of procedures for linking key comparison data, a bilateral comparison would help to provide assurance of equality in measurements between the participating laboratories. With this end, the comparison SIM.EM-S9.b of 1 ohm and 10 kiloohm standard resistors of INIMET (Cuba) and INTI was carried out from March to October 2012. The obtained results were very good. They show that the resistance standards maintained by INTI and INIMET were equivalent, within their combined uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. SUPPLEMENTARY COMPARISON Bilateral comparison on the calibrations of hydrometers for liquid density between INRIM-Italy and INMETRO-Brazil: SIM.M.D-S2

    NASA Astrophysics Data System (ADS)

    Lorefice, Salvatore; Malta, Dalni; Julio Pinheiro, José; Marteleto, Paulo Roberto

    2010-01-01

    The results of the SIM.M.D-S2 bilateral comparison between INRIM-Italy and INMETRO-Brazil are summarized in this report. The aims of this comparison were to check the stated uncertainty levels and the degrees of equivalence between the two institutes on the calibration of hydrometers for liquid density in the range of 800 kg m-3 to 1000 kg m-3 at 20 ºC, by means of two transfer standards of excellent metrological characteristics. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. Bilateral Comparison of Blackbodies for Clinical Infrared Ear Thermometers between NIMT and NMIJ

    NASA Astrophysics Data System (ADS)

    Manoi, A.; Norranim, U.; Kaneko, Y.; Ishii, J.

    2014-04-01

    This article describes the results of the bilateral comparison of blackbodies for infrared ear thermometers (IRETs) between the National Institute of Metrology (Thailand), NIMT, and the National Metrology Institute of Japan (NMIJ). The purpose of this comparison was to ensure consistency of the national radiance temperature scales for IRETs maintained by NIMT and NMIJ. Results of the measurements indicate differences in radiance temperature within 10 mK with a maximum measurement uncertainty of 64 mK. The equivalence of the radiance temperature scales realized by both NIMT and NMIJ in the range of 35 C to 42 C for IRET calibration is indicated. The results of this bilateral comparison can be used in terms of quality assurance and validation of calibration.

  16. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. KEY COMPARISON: CCQM-K21 Key Comparison Determination of pp’-DDT in fish oil

    NASA Astrophysics Data System (ADS)

    Webb, K. S.; Carter, D.; Wolff Briche, C. S. J.

    2003-01-01

    A key comparison on the determination of (pp'-dichlorodiphenyl) trichloroethane (pp'-DDT) in a fish oil matrix has been successfully completed. Nine NMIs participated in this key comparison and used the technique of isotope dilution gas-chromatography mass spectrometry (ID/GC/MS) for the determinations. Two samples (A and B) of fish oil were distributed to participants, each gravimetrically spiked with pp'-DDT. The KCRV for Sample A is 0.0743 +/- 0.0020 µg g-1 and that of Sample B is 0.1655 +/- 0.0014 µg g-1 of pp'-DDT in fish oil. The results for Sample A showed a RSD of 3.5%, the RSD for Sample B was within 1%. These results were an improvement over those of the corresponding pilot study (CCQM-P21), where at a mass fraction of pp'-DDT in fish oil of 0.311 µg g-1 the RSD was 2.6%. The compound pp'-DDT is a typical organochlorine pesticide and this key comparison has shown that NMIs have the ability to measure such compounds at levels typically found in the environment. The compound (pp'-dichlorodiphenyl) dichloroethylene (pp'-DDE), a metabolite of pp'-DDT, was the subject of a previous key comparison (CCQM-K5). The compound pp'-DDT is technically more challenging than that of pp'-DDE since it can decompose during the measurement procedure. Consequently the success of this key comparison, combined with that of CCQM-K5 demonstrates a broad measurement capability by NMIs for organochlorine compounds in the environment. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  18. Final report on APMP.T-K7.1 key comparison of water triple point cells, bilateral NMIJ-VMI

    NASA Astrophysics Data System (ADS)

    Yamazawa, Kazuaki; Nakano, Tohru; Thanh Binh, Pham

    2018-01-01

    APMP.T-K7.1, was held from July 2014 to May 2015 to compare the national realizations of the water triple point between NMIJ (Japan) and VMI (Vietnam). To reach the objective, VMI sent a transfer cell to NMIJ and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the NMIJ and at the VMI, and aims to link the results of APMP.T-K7.1 to APMP.T-K7 and CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report of EURAMET 1197: Supplementary bilateral comparison of hydraulic gauge pressure standards up to 50 MPa

    NASA Astrophysics Data System (ADS)

    Durgut, Yasin; Petrovski, Nenad; Kacarski, Vanco

    2012-01-01

    Interlaboratory comparisons are important for the laboratories to assess their own measurement capability. It is equally important for the accreditation bodies and assessors during the audit process of a laboratory to judge whether the laboratory is doing well. As per accreditation rules, it is mandatory for the testing and calibration laboratories to participate in such comparisons from time to time. In this report, results of the bilateral interlaboratory comparison in pressure area in hydraulic media up to 50 MPa gauge between UME (Turkey) and BOM (The FYR of Macedonia) are presented. The artefact used for the comparison was a digital pressure calibrator and its drift was taken into account in the calculation. Results show that all En values lie in acceptable limits. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral comparison on the calibration of a set of F1 mass standards between IBMETRO (Bolivia) and INTI (Argentina)

    NASA Astrophysics Data System (ADS)

    Quille, Ruben; Sanchez, Jorge; Escalante, Boris

    2017-01-01

    Mass calibration is an important activity for National Metrology Institutes (NMIs), due to the amount of measurements on scientific, industrial and legal activities that have traceability to the national mass standards of each country. In order to evaluate the stated uncertainty and degree of equivalence between INTI-Argentina and IBMETRO-Bolivia on mass calibration a bilateral comparison was agreed between both laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. KEY COMPARISON: Final report, on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII, 2007

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez Blaya, Carmen

    2009-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone mole fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Final report on APMP.M.M.K4.1—bilateral comparison of 1 kg stainless steel mass standards between KRISS and A*STAR

    NASA Astrophysics Data System (ADS)

    Chung, J. W.; Lee, S. M.; Lee, S. J.

    2017-01-01

    This report describes a bilateral comparison of 1 kg stainless steel mass standard between the Korea Research Institute of Standards and Science (KRISS), and the National Measurement Centre, Agency for Science, Technology and Research (A*STAR), Singapore, which is registered in the BIPM KCDB as APMP.M.M-K4.1. This nominal value was chosen as it followed the nominal value of CCM.M-K4. This bilateral comparison was piloted by KRISS. The transfer weight was delivered to A*STAR from KRISS in April 2015 and received back from A*STAR in October 2015. A*STAR are aiming to improve their calibration measurement capability (CMC) for mass of 1 kg. KRISS participated in both this comparison and CCM.M-K4, providing a link between the A*STAR result and the KCRV of CCM.M-K4. The final report of this comparison is given in this document. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. KEY COMPARISON: Final report of EUROMET Project 696: pH determination of a phthalate buffer

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Charlet, Philippe; Eberhard, Ralf; Karpov, Oleg V.; Philippe, Rachel; Rivier, Cedric; Maximov, Igor; Sudmeier, Uwe

    2005-01-01

    The EUROMET project 696, a trilateral comparison between PTB, Germany, LNE, France and VNIIFTRI, Russia was performed in order to demonstrate and document the capability of the participants to measure the pH of a phthalate buffer by the primary measurement procedure for pH. Good agreement of the reported results was observed. The sample was very similar to the one used in the comparison CCQM-K17. PTB acts as pilot laboratory in CCQM-K17 and in EUROMET 696. This comparison allows one to link the results obtained by LNE to the CCQM-K17 key comparison through the degree of equivalence of PTB. On the other hand, the discrepancy between measured pH values at the VNIIFTRI and PTB for the same type of buffer solution decreased, as compared with a bilateral comparison in 1997. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  5. Results and evaluation of key comparison CCM.P-K12.1 for very low helium flow rates (leak rates)

    NASA Astrophysics Data System (ADS)

    Šetina, Janez; Vičar, Martin; Pražák, Dominik

    2015-01-01

    The Czech Metrology Institute (CMI) took part and failed to prove equivalence in the Key Comparison CCM.P-K12 of helium leak artefacts (leak rates) into vacuum. After identifying and eliminating the cause of the failure, the Institute of Metals and Technology (IMT) of Slovenia, a successful participant in CCM.P-K12, volunteered to serve as pilot and link in a following bilateral comparison of IMT and CMI that obtained designation CCM.P-K12.1 in June 2012. It was decided to perform the comparison with a glass permeation helium leak artefact at nominally 3.10-11 mol/s (7.4.10-7 mbar.L.s-1) at 23 °C. Both the laboratory standards took part in CCM.P-K12 and were considered as primary. The comparison measurements were performed in October 2012. CMI proved equivalence both with IMT and with the reference value of the key comparison CCM.P-K12. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. KEY COMPARISON Bilateral comparison of 1.018 V and 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2010 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2010-01-01

    As a part of the ongoing BIPM key comparisons BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and of the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2010. Two BIPM Zener diode-based travelling standards were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage is maintained at the 10 V level by means of a group of characterized Zener diode-based electronic voltage standards. The output EMF of each travelling standard, at the 10 V output terminals, was measured by direct comparison with the group standard. Measurements of the output EMF of the travelling standards at the 1.018 V output terminals were made using a potentiometer, standardized against the local 10 V reference standard. At the BIPM, the travelling standards were calibrated at both voltages before and after the measurements at NSAI-NML, using the BIPM Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. KEY COMPARISON: Final report on international key comparison CCQM-K53: Oxygen in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Bok Lee, Jin; Moon, Dong Min; Seog Kim, Jin; van der Veen, Adriaan M. H.; Besley, Laurie; Heine, Hans-Joachim; Martin, Belén; Konopelko, L. A.; Kato, Kenji; Shimosaka, Takuya; Perez Castorena, Alejandro; Macé, Tatiana; Milton, Martin J. T.; Kelley, Mike; Guenther, Franklin; Botha, Angelique

    2010-01-01

    Gravimetry is used as the primary method for the preparation of primary standard gas mixtures in most national metrology institutes, and it requires the combined abilities of purity assessment, weighing technique and analytical skills. At the CCQM GAWG meeting in October 2005, it was agreed that KRISS should coordinate a key comparison, CCQM-K53, on the gravimetric preparation of gas, at a level of 100 µmol/mol of oxygen in nitrogen. KRISS compared the gravimetric value of each cylinder with an analytical instrument. A preparation for oxygen gas standard mixture requires particular care to be accurate, because oxygen is a major component of the atmosphere. Key issues for this comparison are related to (1) the gravimetric technique which needs at least two steps for dilution, (2) oxygen impurity in nitrogen, and (3) argon impurity in nitrogen. The key comparison reference value is obtained from the linear regression line (with origin) of a selected set of participants. The KCRV subset, except one, agree with each other. The standard deviation of the x-residuals of this group (which consists of NMIJ, VSL, NIST, NPL, BAM, KRISS and CENAM) is 0.056 µmol/mol and consistent with the uncertainties given to their standard mixtures. The standard deviation of the residuals of all participating laboratory is 0.182 µmol/mol. With respect to impurity analysis, overall argon amounts of the cylinders are in the region of about 3 µmol/mol however; four cylinders showed an argon amount fraction over 10 µmol/mol. Two of these are inconsistent with the KCRV subset. The explicit separation between two peaks of oxygen and argon in the GC chromatogram is essential to maintain analytical capability. Additionally oxygen impurity analysis in nitrogen is indispensable to ensure the preparative capability. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The

  8. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2011-01-01

    As a part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2011. Two BIPM Zener diode-based travelling standards (Fluke 732B) were transported by freight to NSAI-NML. At NSAI-NML, the 10 V output EMF of each travelling standard was measured by direct comparison with a group of characterized Zener diode-based electronic voltage standards. At the BIPM, the travelling standards were calibrated before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. KEY COMPARISON: Final report of International Comparison EUROMET.QM-K1c: Comparison of measurements of nitrogen monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, A. M. H.; Nieuwenkamp, G.; Oudwater, R.; Wessel, R. M.; Novak, J.; Perrochet, J.-F.; Ackermann, A.; Rakowska, A.; Cortez, L.; Dias, F.; Konopelko, L.; Kustikov, Y.; Sutour, C.; Masé, T.; Milton, M. J. T.; Uprichard, I. J.; Woods, P. T.; Walden, J.; Lopez Esteban, M. T.

    2005-01-01

    Following-up the key comparison CCQM-K1c, EUROMET organized a regional key comparison involving ten laboratories. The objectives of this EUROMET key comparison were essentially the same as for the CCQM-K1c comparison: to compare the measurement capabilities of national metrological institutes (NMIs) in measuring amount of substance fractions of nitrogen monoxide in nitrogen. The nominal amount of substance fraction of the standards used for the comparison was 100 µmol/mol. The pilot laboratory in this key comparison also piloted the CCQM key comparison and has long-term experience in the behaviour of these mixtures and the technical challenges in preparing batches of very similar mixtures. Most participants used chemiluminescence as the measurement method; two participants used UV techniques and one ND-IR. The degrees of equivalence between this comparison and CCQM-K1c were calculated; four laboratories participated in both key comparisons, thus providing sufficient data for demonstrating the comparability. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  10. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out in February and March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_4 (Z4) and BIPM_5 (Z5), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 10 March 2014. UNML - UBIPM = -0.64 µV uc = 1.35 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to

  12. Comparison of Cognitive Parameters Between Bilateral and Unilateral Hippocampal Sclerosis.

    PubMed

    Vanli Yavuz, Ebru Nur; Bilgiç, Başar; Matur, Zeliha; Bebek, Nerses; Gürses, Candan; Gökyiğit, Ayşen; Öktem, Öget; Baykan, Betül

    2016-09-01

    Recent studies showed that hippocampal sclerosis (HS) patients with unilateral involvement had more diffuse cognitive impairment than expected. Therefore, we aimed to compare the cognitive profiles of bilateral HS (BHS) patients with unilateral HS (UHS) patients. Consecutive patients, diagnosed with epilepsy, who fulfilled two major magnetic resonance imaging (MRI) criteria (T1 atrophy and T2-FLAIR hyperintensity) for HS were included. Standard neuro-psychological test (NPT) battery consisted of the Turkish version of 15-word verbal memory processes test, Wechsler memory scale visual reproduction subtest, forward and backward digit span, phonemic and semantic fluency, and Stroop test were applied; and the groups with right HS, left HS, and bilateral HS were compared statistically. Ninety-one patients, completing the NPT (34 males, 57 females)-16 with BHS, 36 with right HS, and 39 with left HS-were included. Six out of 43 operated patients had BHS. There were no significant differences in education and handedness of the groups. Even though NPT performances of the BHS group were found to be poor compared to UHS subgroups, this was beyond statistical significance. Comparison of BHS with the right HS group showed a significant difference in the learning score of the Verbal Memory Processes Test, but recognition scores were found to be similar in all groups. Compared to the BHS group, both right and left HS groups revealed a significant difference in delayed recall score of the Verbal Memory Processes Test. Although there were no significant differences in the postoperative parameters of the BHS group, UHS subgroups had deficits in many postoperative parameters. Our study revealed that bilateral involvement of the hippocampi was correlated with a poor cognitive performance. Retrieval failure, rather than a total recall problem, in the memory of the patients resembles a more diffuse involvement not only limited to limbic structures.

  13. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    NASA Astrophysics Data System (ADS)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in January and February 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM7 (Z7) and BIPM9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V, at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 31 of January 2016. UNML - UBIPM = + 0.22 μV uc = 1.35 μV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Power, O.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in February and March 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMC (ZC), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final resultof the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V,at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 24 February 2015. UNML - UBIPM = - 0.82 mV; uc = 1.35 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Key comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Buchner, Christian; Zelenka, Zoltan; Kajastie, Heikki; Madec, Tanguy; Wolf, Henning; Vámossy, Csilla; Lorefice, Salvatore; Garberg, Torgunn; Lenard, Elżbieta; Spohr, Isabel; Mares, Gabriela; Spurný, Robert; Lumbreras, Angel; Medina, Nieves; Y Akçadağ, Ümit; Perkin, Michael

    2015-01-01

    Hydrostatic density determination for liquids is mainly performed by laboratories to provide means for calibrating liquid density measuring instruments such as oscillation-type density meters. From 2002 to 2005 the CIPM key comparison CCM.D-K2 'comparison of liquid density standards' was carried out piloted by the PTB. The aim was to compare the results of the density determination by the participating laboratories to support entries to the CMC tables in this sub-field. To provide further laboratories the possibility to support their entries to the CMC tables at the meeting of the EUROMET Working Group on Density in 2007 this comparison was agreed on. BEV (Austria) organized the comparison supported by the PTB (Germany). For the comparison samples of pentadecane, water, tetrachloroethylene and of an oil of high viscosity were measured in the temperature range from 5 °C to 60 °C at atmospheric pressure by hydrostatic weighing. The measurements were completed in 2008. The reference values of the first reports based on the draft of the CCM.D-K2. After the official publication of the CCM.D-K2 the reference values were recalculated and the report was finalised in 2015. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. KEY COMPARISON: Key comparison CCQM-K60: Total selenium and selenomethionine in selenised wheat flour

    NASA Astrophysics Data System (ADS)

    Goenaga Infante, Heidi; Sargent, Mike

    2010-01-01

    Key comparison CCQM-K60 was performed to assess the analytical capabilities of national metrology institutes (NMIs) to accurately quantitate the mass fraction of selenomethionine (SeMet) and total selenium (at low mg kg-1 levels) in selenised wheat flour. It was organized by the Inorganic Analysis Working Group (IAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) as a follow-up key comparison to the previous pilot study CCQM-P86 on selenised yeast tablets. LGC Limited (Teddington, UK) and the Institute for National Measurement Standards, National Research Council Canada (NRCC, Ottawa, Canada) acted as the coordinating laboratories. CCQM-K60 was organized in parallel with a pilot study (CCQM-P86.1) involving not only NMIs but also expert laboratories worldwide, thus enabling them to assess their capabilities, discover problems and learn how to modify analytical procedures accordingly. Nine results for total Se and four results for SeMet were reported by the participant NMIs. Methods used for sample preparation were microwave assisted acid digestion for total Se and multiple-step enzymatic hydrolysis and hydrolysis with methanesulfonic acid for SeMet. For total Se, detection techniques included inductively coupled plasma mass spectrometry (ICP-MS) with external calibration, standard additions or isotope dilution analysis (IDMS); instrumental neutron activation analysis (INAA); and graphite furnace atomic absorption spectrometry (GFAAS) with external calibration. For determination of SeMet in the wheat flour sample, the four NMIs relied upon measurements using species-specific IDMS (using 76Se-enriched SeMet) with HPLC-ICP-MS. Eight of the nine participating NMIs reported results for total Se within 3.5% deviation from the key comparison reference value (KCRV). For SeMet, the four participating NMIs reported results within 3.2% deviation from the KCRV. This shows that the performance of the majority of the CCQM-K60 participants was very good

  19. Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants

    PubMed Central

    Dietz, Mathias

    2015-01-01

    In patients with bilateral cochlear implants (CIs), pairing matched interaural electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, and spatial release from masking. Because clinical procedures typically do not include patient-specific interaural electrode pairing, it remains the case that each electrode is allocated to a generic frequency range, based simply on the electrode number. Two psychoacoustic techniques for determining interaurally paired electrodes have been demonstrated in several studies: interaural pitch comparison and interaural time difference (ITD) sensitivity. However, these two methods are rarely, if ever, compared directly. A third, more objective method is to assess the amplitude of the binaural interaction component (BIC) derived from electrically evoked auditory brainstem responses for different electrode pairings; a method has been demonstrated to be a potential candidate for bilateral CI users. Here, we tested all three measures in the same eight CI users. We found good correspondence between the electrode pair producing the largest BIC and the electrode pair producing the maximum ITD sensitivity. The correspondence between the pairs producing the largest BIC and the pitch-matched electrode pairs was considerably weaker, supporting the previously proposed hypothesis that whilst place pitch might adapt over time to accommodate mismatched inputs, sensitivity to ITDs does not adapt to the same degree. PMID:26631108

  20. Final report on bilateral supplementary comparison APMP.M.P-S5 in hydraulic gauge pressure from 1 MPa to 10 MPa

    NASA Astrophysics Data System (ADS)

    Yue, J.; Yang, Y.; Sabuga, W.

    2016-01-01

    This report summarizes the results of the Asia-Pacific Metrology Programme (APMP) supplementary comparison APMP.M.P-S5 for hydraulic gauge pressure in the range of 1 MPa to 10 MPa, which is a bilateral comparison carried out at the National Institute of Metrology, China (NIM) and the Physikalisch-Technische Bundesanstalt, Germany (PTB) during the period June 2014 to June 2015. NIM piloted the comparison and provided the transfer standard, which was a piston-cylinder assembly (PCA) of 1 cm2 nominal effective area built in a hydraulic pressure balance manufactured by Fluke Corporation. The laboratory standards of NIM and PTB are both hydraulic pressure balances equipped with PCAs, of which the nominal effective area is 1 cm2 for NIM and 5 cm2 for PTB. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards of NIM and PTB in the range of 1 MPa to 10 MPa are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Chayramy, R.; Solve, S.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from January to February 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_8 (Z8) and BIPM_9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 February 2013. UNML - UBIPM = -0.63 µV uc = 1.31 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according

  2. [Speech perception with electric-acoustic stimulation : Comparison with bilateral cochlear implant users in different noise conditions].

    PubMed

    Rader, T

    2015-02-01

    Cochlear implantation with the aim of hearing preservation for combined electric-acoustic stimulation (EAS) is the therapy of choice for patients with residual low-frequency hearing. Preserved residual acoustic hearing has a positive effect on speech intelligibility in difficult noise conditions. The goal of this study was to assess speech reception thresholds in various complex noise conditions for patients with EAS in comparison with patients using bilateral cochlear implants (CI). Speech perception in noise was measured for bilateral CI and EAS patient groups. A total of 22 listeners with normal hearing served as a control group. Speech reception thresholds (SRT) were measured using a closed-set sentence matrix test. Speech was presented with a single source in frontal position; noise was presented in frontal position or in a multisource noise field (MSNF) consisting of a four-loudspeaker array with independent noise sources. Modulated speech-simulating noise and pseudocontinuous noise served respectively as interference signal with different temporal characteristics. The average SRTs in the EAS group were significantly better in all test conditions than those of the group with bilateral CI. Both user groups showed significant improvement in the MSNF condition compared with the frontal noise condition as a result of bilateral interaction. The normal-hearing control group was able to use short temporal gaps in modulated noise to improve speech perception in noise (gap listening). This effect was absent in both implanted user groups. Patients with combined EAS in one ear and a hearing aid in the contralateral ear show significantly improved speech perception in complex noise conditions compared with bilateral CI recipients.

  3. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    NASA Astrophysics Data System (ADS)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. SUPPLEMENTARY COMPARISON: Final report of the bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B between PTB and NIMT

    NASA Astrophysics Data System (ADS)

    Sanponpute, Tassanai; Meesaplak, Apichaya; Herrmann, Konrad; Menelao, Febo

    2009-01-01

    The bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B was arranged by the National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison was to confirm the calibration and measurement capabilities of NIMT in hardness measurement. The period of measurement covered March to August 2009. There were two sets of artefacts: scale A artefact set and scale B artefact set. The scale A artefact set consisted of seven hardness blocks: 35 HRA, 40 HRA, 55 HRA, 60 HRA, 70 HRA, 80 HRA, 85 HRA. The artefact set for scale B consisted of nine hardness blocks: 25 HRB, 30 HRB, 40 HRB, 50 HRB, 60 HRB, 70 HRB, 80 HRB, 90 HRB, 100 HRB. Laboratories had to ensure that the primary Rockwell hardness machines passed the verification process according to ISO 6508-3. Then participants measured the hardness value by making ten indentations in a designated area of each artefact block. Hardness measurement results and uncertainty budget were then reported to the pilot laboratory and were used to compute the degrees of equivalence in terms of the Comparison Reference Value (CRV) and En ratio. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -25 °C TO +20 °C.

    PubMed

    Meyer, C W; Hill, K D

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC.

  6. KEY COMPARISON Final report on international comparison CCQM-K71: Measurement of stack gas

    NASA Astrophysics Data System (ADS)

    Nieuwenkamp, G.; van der Veen, A. M. H.; Wessel, R. M.; Qiao, Han; Oh, Sang-Hyub; Kim, Byung-Moon; Kim, Kwang-Sub; Pérez Castorena, Alejandro; Ramírez Nambo, Carlos; Koelliker Delgado, Jorge; Serrano Caballero, Victor M.; Rangel Murillo, Francisco; Avila Salas, Manuel de Jesus; Dias, Florbela; Baptista, Gonçalo; Konopelko, L. A.; Kustikov, Y. A.; Pankratov, V. V.; Selyukov, D. N.; Balandovich, V. S.; Vishnyakov, I. M.; Pavlov, M. V.; Maltsev, M. A.; Botha, Angelique; Valkova, Miroslava; Stovcik, Viliam; Musil, Stanislav; Milton, M. J. T.; Uprichard, I. J.; Vargha, G. M.; Guenther, F.; Gameson, L.; da Cunha, V.

    2010-01-01

    Industrial stack gas emission measurements are important for process control, control of air pollution, and for implementing legislation regarding carbon dioxide emission rights. Measurements are typically performed using a range of process analysers for carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOx), sulphur dioxide (SO2) and miscellaneous hydrocarbons. The calibration of these analysers is often performed using a series of binary mixtures of each component in nitrogen. For reasons of efficiency as well as a better match with true stack gas, the use of multi-component mixtures for this purpose would be preferred. The aim of this key comparison is to evaluate the measurement capabilities of national metrology institutes for carbon monoxide, carbon dioxide, nitrogen monoxide, sulphur dioxide and propane in nitrogen. Ten laboratories participated in the key comparison and one in the associated study. The key comparison reference value is based on the gravimetric preparation data. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2012-01-01

    As part of the on-going BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from February to March 2012. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_C (ZC) and BIPM_D (ZD), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson voltage standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 February 2012. UNML - UBIPM = +0.83 µV, uc = 1.35 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. The final result is impacted by the anomalous offset between the NSAI-NML results for the two transfer standards. The reason for this offset hasn't been determined. However, the difference remains within the total combined standard uncertainty. Therefore, the comparison result shows that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of

  8. Bilateral Comparison of Mercury and Gallium Fixed-Point Cells Using Standard Platinum Resistance Thermometer

    NASA Astrophysics Data System (ADS)

    Bojkovski, J.; Veliki, T.; Zvizdić, D.; Drnovšek, J.

    2011-08-01

    The objective of project EURAMET 1127 (Bilateral comparison of triple point of mercury and melting point of gallium) in the field of thermometry is to compare realization of a triple point of mercury (-38.8344 °C) and melting point of gallium (29.7646 °C) between the Slovenian national laboratory MIRS/UL-FE/LMK and the Croatian national laboratory HMI/FSB-LPM using a long-stem 25 Ω standard platinum resistance thermometer (SPRT). MIRS/UL/FE-LMK participated in a number of intercomparisons on the level of EURAMET. On the other hand, the HMI/LPM-FSB laboratory recently acquired new fixed-point cells which had to be evaluated in the process of intercomparisons. A quartz-sheathed SPRT has been selected and calibrated at HMI/LPM-FSB at the triple point of mercury, the melting point of gallium, and the water triple point. A second set of measurements was made at MIRS/UL/FE-LMK. After its return, the SPRT was again recalibrated at HMI/LPM-FSB. In the comparison, the W value of the SPRT has been used. Results of the bilateral intercomparison confirmed that the new gallium cell of the HMI/LPM-FSB has a value that is within uncertainty limits of both laboratories that participated in the exercise, while the mercury cell experienced problems. After further research, a small leakage in the mercury fixed-point cell has been found.

  9. Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison

    NASA Astrophysics Data System (ADS)

    Newell, D. B.; van Westrum, D.; Francis, O.; Kanney, J.; Liard, J.; Ramirez, A. E.; Lucero, B.; Ellis, B.; Greco, F.; Pistorio, A.; Reudink, R.; Iacovone, D.; Baccaro, F.; Silliker, J.; Wheeler, R. D.; Falk, R.; Ruelke, A.

    2017-01-01

    Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Final report on RMO Vickers key comparison COOMET M.H-K1

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Menelao, F.; Herrmann, K.; Aslanyan, A.; Pivovarov, V.; Galat, E.; Dovzhenko, Y.; Zhamanbalin, M.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales involving five National Metrology Institutes: PTB (Germany), BelGIM (Belarus), NSC IM (Ukraine), KazInMetr (Kazakhstan) and VNIIFTRI (Russia). The pilot laboratory was VNIIFTRI, and PTB acted as the linking institute to key comparisons CCM.H-K1.b and CCM.H-K1.c conducted for the Vickers hardness scales HV1 and HV30, respectively. The comparison was also conducted for the HV5 Vickers hardness scale, since this scale is most frequently used in practice in Russia and CIS countries that work according to GOST standards. In the key comparison, two sets of hardness reference blocks for the Vickers hardness scales HV1, HV5 and HV30 consisting each of three hardness reference blocks with hardness levels of 450 HV and 750 HV were used. The measurement results and uncertainty assessments for HV1 and HV30 hardness scales, as announced by BelGIM, NSC IM, KazInMetr and VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1.b and CCM.H-K1.c. The comparison results for the HV5 hardness scale are viewed as additional information, since up to today no CCM key comparisons on this scale have yet been carried out. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −25 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Hill, K.D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952

  12. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    PubMed

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  13. Final report on key comparison APMP.M.P-K3: Absolute pressure measurements in gas from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Yoshida, H.; Arai, K.; Akimichi, H.; Hong, S. S.; Song, H. W.

    2011-01-01

    The results of a key comparison of ultra-high vacuum standards at two national metrology institutes (NMIJ/AIST and KRISS) are reported. This bilateral comparison was carried out from May 2010 to October 2010 within the framework of the Asia-Pacific Metrology Programme (APMP) to determine their degrees of equivalence at pressures in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. The pilot institute was NMIJ/AIST. Two spinning rotor gauges and two hot cathode ionization gauges were used as the transfer standards. NMIJ/AIST used two calibration systems: the dynamic expansion system (NMIJ-DES) and two-stage flow-dividing system (NMIJ-TFS). KRISS used the dynamic expansion system. The transfer standards were sufficiently stable to meet the requirements of the comparison compared with those of previous international comparisons owing to some improvements of the protocol and the transfer standards. The ultra-high vacuum standards of NMIJ/AIST and KRISS were found to be equivalent within their claimed uncertainties in the range from 3 × 10-6 Pa to 9 × 10-5 Pa. The NMIJ-DES results, which have smaller uncertainty than NMIJ-TFS, were transferred to the corresponding CCM key comparison, CCM.P-K3, in the range from 3 × 10-6 Pa to 9 × 10-5 Pa and it is shown that the NMIJ values were equivalent to the CCM key comparison reference value within the claimed uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    PubMed Central

    Vilar, César; Hida, Wilson Takashi; de Medeiros, André Lins; Magalhães, Klayny Rafaella Pereira; de Moraes Tzelikis, Patrick Frensel; Chaves, Mario Augusto Pereira Dias; Motta, Antônio Francisco Pimenta; Carricondo, Pedro Carlos; Alves, Milton Ruiz; Nosé, Walton

    2017-01-01

    Purpose To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. Methods This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve. Results Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision. Conclusion Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions. PMID:28814826

  15. Final report on VMI-NMISA bilateral comparison APMP.T-K3.1: Realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans

    2012-01-01

    The Comité Consulatif de Thermométrie (CCT) has organized several key comparisons to compare realizations of the ITS-90 in different National Metrology Institutes. To keep the organization, time scale and data processing of such a comparison manageable, the number of participants in a CCT key comparison (CCT KC) is limited to a few laboratories in each major economic region. Subsequent regional key comparisons are linked to the applicable CCT KC by two or more linking laboratories. For the temperature range from 83.8058 K (triple point of Ar) to 933.473 K (freezing point of Al), a key comparison, CCT-K3, was carried out from 1997 to 2001 among representative laboratories in North America, Europe and Asia. Following CCT-K3, the Asia-Pacific Metrology Program Key Comparison 3 (APMP.T-K3) was organized for National Metrology Institutes in the Asia/Pacific region. NMIA (Australia) and KRISS (South Korea) provided the link between CCT-K3 and APMP.T-K3. APMP.T-K3, which took place from February 2000 to June 2003, covered the temperature range from -38.8344 °C (triple point of Hg) to 419.527 °C (freezing point of Zn), using a standard platinum resistance thermometer (SPRT) as the artefact. In June 2007 the Vietnam Metrology Institute (VMI) requested a bilateral comparison to link their SPRT calibration capabilities to APMP.T-K3, and in October 2007 the National Metrology Institute of South Africa (NMISA) agreed to provide the link to APMP.T-K3. Like APMP.T-K3, the comparison was restricted to the Hg to Zn temperature range to reduce the chance of drift in the SPRT artefact. The comparison was carried out in a participant-pilot-participant topology (with NMISA as the pilot and VMI as the participant). VMI's results in the comparison were linked to the Average Reference Values of CCT-K3 via NMISA's results in APMP.T-K3. The resistance ratios measured by VMI and NMISA at Zn, Sn, Ga and Hg fixed points agree within their combined uncertainties, and VMI's results also

  16. A review of bilateral training for upper extremity hemiparesis.

    PubMed

    Stoykov, Mary Ellen; Corcos, Daniel M

    2009-01-01

    Upper extremity hemiparesis is the most common post-stroke disability. Longitudinal studies have indicated that 30-66% of stroke survivors do not have full arm function 6 months post-stroke. The current gold standard for treatment of mild post-stroke upper limb impairment is constraint-induced therapy but, because of the inclusion criteria, alternative treatments are needed which target more impaired subjects. Bilateral arm training has been investigated as a potential rehabilitation intervention. Bilateral arm training encompasses a number of methods including: (1) bilateral isokinematic training; (2) mirror therapy using bilateral training; (3) device-driven bilateral training; and (4) bilateral motor priming. Neural mechanisms mediating bilateral training are first reviewed. The key bilateral training studies that have demonstrated evidence of efficacy will then be discussed. Finally, conclusions are drawn concerning clinical implications based on the reviewed literature. (c) 2009 John Wiley & Sons, Ltd.

  17. Final report of the regional key comparison EURAMET.M.G-K1: European Comparison of Absolute Gravimeters ECAG-2011

    NASA Astrophysics Data System (ADS)

    Francis, Olivier; Klein, Gilbert; Baumann, Henri; Dando, Nicolas; Tracey, Ray; Ullrich, Christian; Castelein, Stefaan; Hua, Hu; Kang, Wu; Chongyang, Shen; Songbo, Xuan; Hongbo, Tan; Zhengyuan, Li; Pálinkás, Vojtech; Kostelecký, Jakub; Mäkinen, Jaakko; Näränen, Jyri; Merlet, Sébastien; Farah, Tristan; Guerlin, Christine; Pereira Dos Santos, Franck; Le Moigne, Nicolas; Champollion, Cédric; Deville, Sabrina; Timmen, Ludger; Falk, Reinhard; Wilmes, Herbert; Iacovone, Domenico; Baccaro, Francesco; Germak, Alessandro; Biolcati, Emanuele; Krynski, Jan; Sekowski, Marcin; Olszak, Tomasz; Pachuta, Andrzej; Agren, Jonas; Engfeldt, Andreas; Reudink, René; Inacio, Pedro; McLaughlin, Daniel; Shannon, Geoff; Eckl, Marc; Wilkins, Tim; van Westrum, Derek; Billson, Ryan

    2012-01-01

    During November 2011 a EURAMET key comparison of absolute gravimeters was organized in the Underground Laboratory for Geodynamics in Walferdange, Luxemburg. The comparison assembled 22 participants coming from 16 countries and four different continents. The comparison was divided into two parts: a key comparison that included six National Metrology Institutes or Designated Institutes, and a pilot study including all participants. The global result given by the pilot study confirms that all instruments are absolutely coherent with each other. The results obtained in the key comparison confirm a good agreement between the NMI instruments. Finally, a link to ICAG-2009 shows also that the NMI gravimeters are stable in time. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  19. Efficacy of combined metformin-letrozole in comparison with bilateral ovarian drilling in clomiphene-resistant infertile women with polycystic ovarian syndrome.

    PubMed

    Abd Elgafor, Ibrahim

    2013-07-01

    To compare the hormonal-metabolic profiles and reproductive outcomes between women receiving metformin plus letrozole and women undergoing bilateral ovarian drilling in clomiphene citrate (CC)-resistant women with polycystic ovary syndrome (PCOS). In this randomized study, 146 patients were randomly allocated into group 1 (n = 73) who received metformin plus letrozole, and group 2 (n = 73) who underwent bilateral ovarian drilling. Comparison was done between the basal and after treatment biochemical values for each group, in addition reproductive outcomes after treatment were compared between both groups. There was significant reduction in testosterone (p ≤ 0.001), fasting insulin (p ≤ 0.001), and fasting glucose/fasting insulin ratio (p = 0.029) in metformin plus letrozole group, while there was significant reduction in FSH, LH and LH/FSH ratio in bilateral drilling group (p ≤ 0.001, 0.001 and 0.001). No significant difference in cycle regularity (p = 0.82), ovulation (p = 0.24), pregnancy rate (p = 0.32) and abortion rate (p = 0.51) between both groups. Both metformin plus letrozole and bilateral ovarian drilling are similarly effective as second-line strategies for the treatment of women with PCOS who do not conceive with CC.

  20. Final report on CCM key comparison CCM.D-K2: Comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Jacques, Claude; Zelenka, Zoltán; Fujii, Ken-ichi; Kuramoto, Naoki; Chang, Kyung-Ho; Lee, Yong Jae; Becerra, Luis Omar; Domostroeva, Natalia

    2013-01-01

    The results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10-5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database

  1. Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII (December 2014)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2015-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Bilateral comparison of 1 V and 10 V standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Simionescu, M.; Cîrneanu, L.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Institut National de Metrologie (INM), Bucharest, Romania, was carried out from August to October 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_8 (Z8), were transported by freight to INM. At INM, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at INM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by INM, at the level of 1.018 V and 10 V, at INM, UINM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 6 September 2013. UINM - UBIPM = -0.014 µV uc = 0.051 µV, at 1 V UINM - UBIPM = -0.43 µV uc = 0.34 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at INM, based on KJ-90, and the uncertainty related to the comparison. These are satisfactory results. The comparison results show that the voltage standards maintained by INM and the BIPM were equivalent, within the comparison uncertainty, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual

  3. Final report of the APMP water flow key comparison: APMP.M.FF-K1

    NASA Astrophysics Data System (ADS)

    Lee, Kwang-Bock; Chun, Sejong; Terao, Yoshiya; Thai, Nguyen Hong; Tsair Yang, Cheng; Tao, Meng; Gutkin, Mikhail B.

    2011-01-01

    The key comparison, APMP.M.FF-K1, was undertaken by APMP/TCFF, the Technical Committee for Fluid Flow (TCFF) under the Asia Pacific Metrology Program (APMP). One objective of the key comparison was to demonstrate the degree of equivalence among six participating laboratories (KRISS, NMIJ, VMI, CMS, NIM and VNIIM) in water flow rate metrology by comparing the results with the key comparison reference value (KCRV) determined from the CCM.FF-K1 key comparison. The other objective of this key comparison was to provide supporting evidence for the calibration and measurement capabilities (CMCs), which had been declared by the participating laboratories during this key comparison. The Transfer Standard Package (TSP) was a Coriolis mass flowmeter, which had been used in the CCM.FF-K1 key comparison. Because the K-factors in the APMP.M.FF-K1 key comparison were slightly lower than the K-factors of the CCM.FF-K1 key comparison due to long-term drifts of the TSP, a correction value D was introduced. The value of D was given by a weighted sum between two link laboratories (NMIJ and KRISS), which participated in both the CCM.FF-K1 and the APMP.M.FF-K1 key comparisons. By this correction, the K-factors were laid between 12.004 and 12.017 at either low (Re = 254 000) or high (Re = 561 000) flow rates. Most of the calibration data were within expected uncertainty bounds. However, some data showed undulations, which gave large fluctuations of the metering factor at Re = 561 000. Calculation of degrees of equivalence showed that all the participating laboratories had deviations between -0.009 and 0.007 pulses/kg from the CCM.FF-K1 KCRV at either the low or the high flow rates. In case of En calculation, all the participating laboratories showed values less than 1, indicating that the corrected K-factors of all the laboratories were equivalent with the KCRV at both Re = 254 000 and 561 000. When the corrected K-factors from two participating laboratories were compared, all the

  4. Bilateral Comparison of 1 V and 10 V Standards between the NIS (Egypt) and the BIPM, August to September 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Abdel Mageed, Hala M.; Aladdin, Omar M.; Raouf, M. Helmy A.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMB (ZB) and BIPMC (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, UNIS, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 7 September 2014. UNIS - UBIPM = 0.09 µV uc = 0.08 µV, at 1 V UNIS - UBIPM = 0.22 µV uc = 0.14 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM

  5. Bilateral Coordination of Children who are Blind.

    PubMed

    Rutkowska, Izabela; Lieberman, Lauren J; Bednarczuk, Grzegorz; Molik, Bartosz; Kazimierska-Kowalewska, Kalina; Marszałek, Jolanta; Gómez-Ruano, Miguel-Ángel

    2016-04-01

    The purpose of this study was to evaluate the bilateral coordination in children and adolescents with visual impairments aged 7 to 18 years in comparison to their sighted peers. An additional objective was to identify the influence of sex and age on bilateral coordination. Seventy-five individuals with congenital severe visual impairment (40 girls and 35 boys) comprised the visually impaired group. The Sighted group comprised 139 youth without visual impairment. Subtest 4 of the Bruininks-Oseretsky Test of Motor Proficiency was administered to test bilateral coordination. To analyze the effect of the independent variables in the results obtained in the Subtest 4, four linear regression models were applied according to group and sex. The results indicated that severe visual impairment and lack of visual sensation had a negative effect on the development of participants' bilateral coordination, which however did not depend on sex or age. © The Author(s) 2016.

  6. Bilateral Testicular Tumors Resulting in Recurrent Cushing Disease After Bilateral Adrenalectomy.

    PubMed

    Puar, Troy; Engels, Manon; van Herwaarden, Antonius E; Sweep, Fred C G J; Hulsbergen-van de Kaa, Christina; Kamphuis-van Ulzen, Karin; Chortis, Vasileios; Arlt, Wiebke; Stikkelbroeck, Nike; Claahsen-van der Grinten, Hedi L; Hermus, Ad R M M

    2017-02-01

    Recurrence of hypercortisolism in patients after bilateral adrenalectomy for Cushing disease is extremely rare. We present a 27-year-old man who previously underwent bilateral adrenalectomy for Cushing disease with complete clinical resolution. Cushingoid features recurred 12 years later, with bilateral testicular enlargement. Hormonal tests confirmed adrenocorticotropic hormone (ACTH)-dependent Cushing disease. Surgical resection of the testicular tumors led to clinical and biochemical remission. Gene expression analysis of the tumor tissue by quantitative polymerase chain reaction showed high expression of all key steroidogenic enzymes. Adrenocortical-specific genes were 5.1 × 105 (CYP11B1), 1.8 × 102 (CYP11B2), and 6.3 × 104 (MC2R) times higher than nonsteroidogenic fibroblast control. This correlated with urine steroid metabolome profiling showing 2 fivefold increases in the excretion of the metabolites of 11-deoxycortisol, 21-deoxycortisol, and total glucocorticoids. Leydig-specific genes were 4.3 × 101 (LHCGR) and 9.3 × 100 (HSD17B3) times higher than control, and urinary steroid profiling showed twofold increased excretion of the major androgen metabolites androsterone and etiocholanolone. These distinctly increased steroid metabolites were suppressed by dexamethasone but unresponsive to human chorionic gonadotropin stimulation, supporting the role of ACTH, but not luteinizing hormone, in regulating tumor-specific steroid excess. We report bilateral testicular tumors occurring in a patient with recurrent Cushing disease 12 years after bilateral adrenalectomy. Using mRNA expression analysis and steroid metabolome profiling, the tumors demonstrated both adrenocortical and gonadal steroidogenic properties, similar to testicular adrenal rest tumors found in patients with congenital adrenal hyperplasia, suggesting the presence of pluripotent cells even in patients without congenital adrenal hyperplasia. Copyright © 2017 by the Endocrine Society

  7. KEY COMPARISON: Final report of APMP.T-K6 (original name APMP-IC-1-97): Comparison of humidity measurements using a dew point meter as a transfer standard

    NASA Astrophysics Data System (ADS)

    Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.

    2007-01-01

    This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII, March 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NPL, April 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Sweeney, Bryan; Quincey, Paul

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone standard of the United Kingdom maintained by the National Physical Laboratory (NPL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with VSL, September 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Heikens, Dita; van der Veen, Adrian

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Netherlands maintained by the Van Swinden (VSL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NIST, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Hodges, Joe; Norris, James E.

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the National Institute of Standards and Technology (NIST) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with INECC, September 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Fentanes, Oscar; Benítez, Ángeles; Ordoñez, Daniel

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of Mexico maintained by the National Institute of Ecology and Climate Change (INECC) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Bilateral Comparison of 1 V and 10 V Standards between the SMD (Belgium) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Vlad, D.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Service Métrologie—Metrologische Dienst (SMD), Brussel, Belgium, was carried out from October to November 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to SMD and also back to BIPM. At SMD, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at SMD, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by SMD, at the level of 1.018 V and 10 V, at SMD, USMD, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 November 2014. USMD - UBIPM = 0.14 mV; uc = 0.07 mV, at 1 V USMD - UBIPM = 0.09 mV; uc = 0.49 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at SMD, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral Comparison of 1 V and 10 V Standards between the JV (Norway) and the BIPM, January to February 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Sengebush, F.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Justervesenet (JV), Kjeller, Norway, was carried out from January to February 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to JV and also back to BIPM. At JV, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at JV, withthe Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by JV, at the level of 1.018 V and 10 V, at JV, UJV, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 28 January 2015. UJV - UBIPM = 0.23 μV uc = 0.03 μV , at 1 V UJV - UBIPM = 0.63 μV uc = 0.28 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at JV, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Bilateral Comparison of 1 V and 10 V Standards between the NIMT (Thailand) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute of Metrology (Thailand), NIMT, was carried out from October to December 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPM6 (Z6), were transported by freight to NIMT and back to BIPM. At NIMT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIMT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by NIMT, at the level of 1.018 V and 10 V, at NIMT, UNIMT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 November 2014. UNIMT - UBIPM = 0.16 mV; uc = 0.14 mV, at 1 V UNIMT - UBIPM = - 0.03 mV; uc = 0.11 mV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIMT, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Report to the CCT on COOMET comparison COOMET.T-K3.1 (previously COOMET.T-S1): Key regional comparison of the national standards of temperature in the range from the triple point of water to the freezing point of zinc

    NASA Astrophysics Data System (ADS)

    Pokhodun, A. I.

    2010-01-01

    In the framework of the CIPM MRA, a first COOMET comparison "Comparison of the ITS-90 realizations in the range from 0.01 °C to 429.7485 °C (from the triple point of water to the freezing point of zinc)", registered in the KCDB under the identifier "COOMET.T-K3", was carried out in 2005-2007. Four national metrology institutes took part in this comparison: VNIIM (Russian Federation), SMU (Slovakia), BelGIM (Republic of Belarus) and NSC IM (Ukraine), and two of them (VNIIM and SMU) ensured the linkage with key comparisons CCT-K3 and CCT-K4, in order to disseminate the metrological equivalence to the measurement standards of NSC IM and BelGIM. NSC IM, however, had to withdraw its results, and at the meeting of Technical Committee T-10 of COOMET it was decided to carry out a supplementary bilateral comparison between VNIIM and the NSC IM for realization of the ITS-90 in the same range of temperature. This was registered in the KCDB under the identifier COOMET.T-S1 and measurements were performed in 2008-2009. From the results presented in this report, it is possible to draw the conclusion that the COOMET supplementary comparison COOMET.T-S1 demonstrates the CMC uncertainties claimed by the NSC IM for the melting point of gallium 0.236 mK (k = 2), and the freezing points of indium 1.040 mK (k = 2), tin 0.858 mK (k = 2) and zinc 0.944 mK (k = 2). In September 2012 the Working Group on key Comparisons (WG 7) of the CCT upgraded this comparison to a COOMET key comparison of the 'CCT-K3' type. It is now identified as COOMET.T-K3.1. In April 2013 this report was superseded by item 03006 in the Technical Supplement of 2013. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. KEY COMPARISON: Final Report on EUROMET.T-K3: Regional key comparison of the realisations of the ITS-90 from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Renaot, E.; Hermier, Y.; Valin, M.; Bonnier, G.

    2007-01-01

    during a Workshop organized by the pilot in Vienna in April 2005 to use as ERV the weighted mean rather than the simple mean. The differences (TLab - TERV) are presented with the associated uncertainties. Given that the protocol of the comparison contains a detailed description of how the uncertainties are to be calculated, the uncertainty budgets established by the participants seem consistent or, at least, homogeneous. The degrees of equivalence between the participating laboratories (in the same loop or in different loops) are given with their associated uncertainty. Finally, a method for establishing the bilateral equivalence between the participants in CCT-K3 and in EUROMET'T-K3 is proposed. It is recommend to use a group of 'linking laboratories' composed by the pilot and the co-pilots in order to link EUROMET.T-K3 to CCT-K3. The hypothesis is that the mean temperature of the pilot and co-pilot laboratories is the same in EUROMET.T-K3 as it was in CCT-K3. A specific analysis of the pilot's and co-pilot's results shows that even when the results given by one or several members of the 'linking laboratories' are not positioned in the same place as in EUROMET.T-K3 and CCT-K3 the mean calculated for the group is really reproducible. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  18. Final report of the key comparison of APMP.AUV.V-K2

    NASA Astrophysics Data System (ADS)

    Usuda, Takashi; Ota, Akihiro; Nozato, Hideaki; Ishigami, Tamio; Kokuyama, Wataru; Plangsangmas, Virat; Rattanangkul, Pairoj; Yih Tsuei, Kuang; Huang, Yu-Chung; Chee Keong, Chan; Shan, Cui

    2017-01-01

    A key comparison of vibration acceleration APMP.AUV.V-K2, which is an upgrade from APMP.AUV.V-K1.1, has been made within the Asia Pacific Metrology Programme (APMP) to include three national laboratories; the CMS-ITRI (Chinese Taipei), the NIMT (Thailand) and the A*Star (Singapore). One pilot laboratory, the NMIJ (Japan), participated to link the RMO APMP results to the CIPM CC key comparison (CCAUV.V-K2), according to the decision of the CCAUV10/D7 during the 10th CCAUV meeting. The admissible acceleration amplitude ranges from 10 m/s2 to 200 m/s2 over the frequency range from 40 Hz to 5 kHz. The RMO APMP results demonstrate the agreement with the key comparison reference value of CCAUV.V-K2 within the expanded uncertainties considering the armature effect of vibration exciter in a high-frequency range. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. SIM key comparison for luminous flux. SIM.PR-K4

    NASA Astrophysics Data System (ADS)

    Matamoros, Carlos H.; Ohno, Yoshi; Zwinkels, Joanne; Cogno, Jorge A.; Couceiro, Iakyra B.

    2016-01-01

    In compliance with the established BIPM and CCPR policies and guidelines on comparisons, the SIM Photometry and Radiometry Working Group decided to conduct a key comparison on total luminous flux in order to provide an opportunity for its member National Metrology Institutes (NMIs) that did not participate in the CCPR-K4 comparison, to get a link to the reference value obtained for this quantity (the lumen) and to derive the corresponding degrees of equivalence. This SIM.PR-K4 was piloted by Centro Nacional de Metrología (CENAM), the NMI of Mexico and included the participation of five laboratories: CENAM (Mexico), INTI (Argentina), INMETRO (Brazil), NIST (USA, linking lab), and NRC (Canada, linking lab). The comparison, conducted in star type scheme, was run using three to four lamps per participant, and results are given in this report, including the unilateral degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. The comparison and analysis of extracting video key frame

    NASA Astrophysics Data System (ADS)

    Ouyang, S. Z.; Zhong, L.; Luo, R. Q.

    2018-05-01

    Video key frame extraction is an important part of the large data processing. Based on the previous work in key frame extraction, we summarized four important key frame extraction algorithms, and these methods are largely developed by comparing the differences between each of two frames. If the difference exceeds a threshold value, take the corresponding frame as two different keyframes. After the research, the key frame extraction based on the amount of mutual trust is proposed, the introduction of information entropy, by selecting the appropriate threshold values into the initial class, and finally take a similar mean mutual information as a candidate key frame. On this paper, several algorithms is used to extract the key frame of tunnel traffic videos. Then, with the analysis to the experimental results and comparisons between the pros and cons of these algorithms, the basis of practical applications is well provided.

  1. Final report, on-going key comparison BIPM.QM-K1: ozone at ambient level, comparison with DMDM, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, J.; Moussay, P.; Wielgosz, R.; Bebic, J.; Norris, J. E.; Guenther, F.

    2016-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Directorate of Measures and Precious Metals (DMDM) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NMISA, June 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Ntsasa, Napo G.; Tshilongo, James; Mphaphuli, Gumani E.; Norris, James E.; Hodges, Joseph T.

    2018-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of South Africa maintained by the National Metrology Institute of South Africa (NMISA) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2010)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2011-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2012)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2013-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. A comparison of critical heat flux in tubes and bilaterally heated annuli

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doerffer, S.; Groeneveld, D.C.; Cheng, S.C.

    1995-09-01

    This paper examines the critical heat flux (CHF) behaviour for annular flow in bilaterally heated annuli and compares it to that in tubes and unilaterally heated annuli. It was found that the differences in CHF between bilaterally and unilaterally heated annuli or tubes strongly depend on pressure and quality. the CHF in bilaterally heated annuli can be predicted by tube CHF prediction methods for the simultaneous CHF occurrence at both surfaces, and the following flow conditions: pressure 7-10 MPa, mass flux 0.5-4.0 Mg/m{sup 2}s and critical quality 0.23-0.9. The effect on CHF of the outer-to-inner surface heat flux ratio, wasmore » also examined. The prediction of CHF for bilaterally heated annuli was based on the droplet-diffusion model proposed by Kirillov and Smogalev. While their model refers only to CHF occurrence at the inner surface, we extended it to cases where CHF occurs at the outer surface, and simultaneously at both surfaces, thus covering all cases of CHF occurrence in bilaterally heated annuli. From the annuli CHF data of Becker and Letzter, we derived empirical functions required by the model. the proposed equations provide good accuracy for the CHF data used in this study. Moreover, the equations can predict conditions at which CHF occurs simultaneously at both surfaces. Also, this method can be used for cases with only one heated surface.« less

  6. Gender comparisons between unilateral and bilateral landings.

    PubMed

    Weinhandl, Joshua T; Joshi, Mukta; O'Connor, Kristian M

    2010-11-01

    The increased number of women participating in sports has led to a higher knee injury rate in women compared with men. Among these injuries, those occurring to the ACL are commonly observed during landing maneuvers. The purpose of this study was to determine gender differences in landing strategies during unilateral and bilateral landings. Sixteen male and 17 female recreational athletes were recruited to perform unilateral and bilateral landings from a raised platform, scaled to match their individual jumping abilities. Three-dimensional kinematics and kinetics of the dominant leg were calculated during the landing phase and reported as initial ground contact angle, ranges of motion (ROM) and peak moments. Lower extremity energy absorption was also calculated for the duration of the landing phase. Results showed that gender differences were only observed in sagittal plane hip and knee ROM, potentially due to the use of a relative drop height versus the commonly used absolute drop height. Unilateral landings were characterized by significant differences in hip and knee kinematics that have been linked to increased injury risk and would best be classified as "stiff" landings. The ankle musculature was used more for impact absorption during unilateral landing, which required increased joint extension at touchdown and may increase injury risk during an unbalanced landing. In addition, there was only an 11% increase in total energy absorption during unilateral landings, suggesting that there was a substantial amount of passive energy transfer during unilateral landings.

  7. KEY COMPARISON: CCQM-K27-Subsequent: Key Comparison (subsequent) for the determination of ethanol in aqueous matrix

    NASA Astrophysics Data System (ADS)

    Schantz, Michele M.; Duewer, David L.; Parris, Reenie M.; May, Willie E.; Archer, Marcellé; Mussell, Chris; Carter, David; Konopelko, Leonid A.; Kustikov, Yury A.; Krylov, Anatoli I.; Fatina, Olga V.

    2005-01-01

    Ethanol is important both forensically ('drunk driving' or driving while under the influence, 'DWI', regulations) and commercially (alcoholic beverages). Blood- and breath-alcohol testing can be imposed on individuals operating private vehicles such as cars, boats, or snowmobiles, or operators of commercial vehicles like trucks, planes, and ships. The various levels of blood alcohol that determine whether these operators are considered legally impaired vary depending on the circumstances and locality. Accurate calibration and validation of instrumentation is critical in areas of forensic testing where quantitative analysis directly affects the outcome of criminal prosecutions, as is the case with the determination of ethanol in blood and breath. Additionally, the accurate assessment of the alcoholic content of beverages is a commercially important commodity. In 2002, the CCQM conducted a Key Comparison (CCQM-K27) for the determination of ethanol in aqueous matrix with nine participants. A report on this project has been approved by the CCQM and can be found at the BIPM website and in this Technical Supplement. CCQM-K27 comprised three samples, one at low mass fraction of ethanol in water (nominal concentration of 0.8 mg/g), one at high level (nominal concentration of 120 mg/g), and one wine matrix (nominal concentration of 81 mg/g). Overall agreement among eight participants using gas chromatography with flame ionization detection (GC-FID), titrimetry, isotope dilution gas chromatography/mass spectrometry (GC-IDMS), and gas chromatography-combustion-isotope ratio mass spectrometry (ID-GC-C-IRMS) was good. The ninth participant used a headspace GC-FID method that had not been validated in an earlier pilot study (CCQM-P35). A follow-on Key Comparison, CCQM-K27-Subsequent, was initiated in 2003 to accommodate laboratories that had not been ready to benchmark their methods in the original CCQM-K27 study or that wished to benchmark a different method. Four levels of

  8. Report of the key comparison APMP.QM-K19. APMP comparison on pH measurement of borate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Obromsook, Krairerk; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Wong, Siu-Kay; Lam, Wai-Hing; Zakaria, Osman; Anuar Mohd. Amin, Khirul; Thanh, Ngo Huy; Máriássy, Michal; Vyskocil, Leos; Hankova, Zuzana; Fisicaro, Paola; Stoica, Daniela; Singh, Nahar; Soni, Daya; Ticona Canaza, Galia; Kutovoy, Viatcheslav; Barbieri Gonzaga, Fabiano; Dias, Júlio Cesar; Vospelova, Alena; Bakovets, Nickolay; Zhanasbayeva, Bibinur

    2015-01-01

    The APMP.QM-K19 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a borate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan (NMIJ) and the National Institute of Metrology (Thailand) (NIMT) at the APMP-TCQM meeting held 26-27 November 2012. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K19 and CCQM-K19.1. The comparison material was a borate buffer of pH around 9.2 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the second APMP key comparison on pH measurement and the fourth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006 and APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Binaural Pitch Fusion in Bilateral Cochlear Implant Users.

    PubMed

    Reiss, Lina A J; Fowler, Jennifer R; Hartling, Curtis L; Oh, Yonghee

    Binaural pitch fusion is the fusion of stimuli that evoke different pitches between the ears into a single auditory image. Individuals who use hearing aids or bimodal cochlear implants (CIs) experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3-4 octaves are fused across ears, leading to spectral averaging and speech perception interference. The goal of this study was to determine if adult bilateral CI users also experience broad binaural pitch fusion. Stimuli were pulse trains delivered to individual electrodes. Fusion ranges were measured using simultaneous, dichotic presentation of reference and comparison stimuli in opposite ears, and varying the comparison stimulus to find the range that fused with the reference stimulus. Bilateral CI listeners had binaural pitch fusion ranges varying from 0 to 12 mm (average 6.1 ± 3.9 mm), where 12 mm indicates fusion over all electrodes in the array. No significant correlations of fusion range were observed with any subject factors related to age, hearing loss history, or hearing device history, or with any electrode factors including interaural electrode pitch mismatch, pitch match bandwidth, or within-ear electrode discrimination abilities. Bilateral CI listeners have abnormally broad fusion, similar to hearing aid and bimodal CI listeners. This broad fusion may explain the variability of binaural benefits for speech perception in quiet and in noise in bilateral CI users.

  10. Final report on the key comparison CCPR-K5: Spectral diffuse reflectance

    NASA Astrophysics Data System (ADS)

    Nadal, Maria; Eckerle, Kenneth L.; Early, Edward A.; Ohno, Yoshi

    2013-01-01

    The CCPR K5 key comparison on spectral diffuse reflectance was carried out in the framework of the CIPM Mutual Recognition Arrangement, by 13 national metrology institutes (MMIs) as participants. The participants were CSIR-NML (South Africa), HUT (Finland), IFA-CSIC (Spain), KRISS (Republic of Korea), MSL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NPL (United Kingdom), NRC (Canada), OMH (Hungary), PTB (Germany) and VNIIOFI (Russia Federation). NIST (USA) piloted the comparison. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 820 nm at 20 nm increment. The comparison was a star type comparison with the samples provided by the pilot laboratory and with the measurement sequence: Pilot-Participant-Pilot. Spectralon and matte white ceramic tiles were used as the transfer standards. Each participant received three of each type of sample and at least one sample of each type was measured three times on three separate days, and the other two samples were measured once. The report presents the description of the measurement facilities, procedures and uncertainties of all the participants as well as the results of the comparison. Measurement results from the participants and their associated uncertainties were analyzed in accordance with the Guidelines for CCPR Key Comparison Report Preparation, using weighted mean with cut-off. For the calculation of the Key Comparison Reference Value (KCRV), as agreed by the participants, the data of both samples were used for the 460 nm to 820 nm region and only the data of the Spectralon samples were used in the spectral region of 360 nm to 440 nm. The unilateral degrees of equivalence (DoE) calculated for each participant are mostly consistent within the uncertainty (k = 2) of the DoE. This international comparison of spectral diffuse reflectance

  11. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with CMS-ITRI, June 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Lin, Tsai-Yin; Norris, James E.; Hodges, Joseph T.

    2017-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the ITRI Center for Measurement Standards (CMS-ITRI) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral aldosterone-producing adenomas: differentiation from bilateral adrenal hyperplasia.

    PubMed

    Wu, V C; Chueh, S C; Chang, H W; Lin, W C; Liu, K L; Li, H Y; Lin, Y H; Wu, K D; Hsieh, B S

    2008-01-01

    Primary aldosteronism (PA) is a common curable disease of secondary hypertension. Most such patients have either idiopathic bilateral adrenal hyperplasia (BAH) or unilateral aldosterone-producing adenoma (APA). Bilateral APAs are reportedly extremely rare. To compare the distinctive characteristics, clinical course, and outcomes of bilateral APA vs. BAH. Retrospective record review. From July 1994 to Jan 2007, 190 patients diagnosed with PA underwent surgical intervention at our hospital. Bilateral APA was diagnosed in 7/164 patients with histologically-proven APA. Twenty-one patients diagnosed as BAH, and 21 randomly selected of unilateral APA patients, matched by age and sex served as controls. Patients with bilateral APA had similar blood pressure, arterial blood gas analysis, spot urinary potassium to creatinine ratio and clinical symptoms to those with BAH, but lower serum potassium levels (p = 0.027), lower plasma renin activity (p = 0.037), and higher plasma aldosterone concentrations (p = 0.029). Aldosterone-renin ratio (ARR) after administration of 50 mg captopril was higher in bilateral APA than in BAH patients (p = 0.023), but not different between unilateral APA and BAH (p = 0.218). A cut-off of ARR >100 ng/dl per ng/ml/h and plasma aldosterone >20 ng/dl after captopril significantly differentiated bilateral APA from BAH. Bilateral subtotal adrenalectomy normalized blood pressure and biochemistry in all patients with bilateral APA. Bilateral APA, presenting simultaneously or sequentially, may not be a rare disease, accounting for 4.3% of APA in this sample. The clinical presentations of bilateral functional adenoma are not different from BAH, but patients with low serum potassium and ARR >100 after captopril should be carefully evaluated for bilateral adenoma.

  13. Regional comparison of absolute gravimeters, EURAMET.M.G-K2 key comparison

    NASA Astrophysics Data System (ADS)

    Pálinkáš, V.; Francis, O.; Val'ko, M.; Kostelecký, J.; Van Camp, M.; Castelein, S.; Bilker-Koivula, M.; Näränen, J.; Lothhammer, A.; Falk, R.; Schilling, M.; Timmen, L.; Iacovone, D.; Baccaro, F.; Germak, A.; Biolcati, E.; Origlia, C.; Greco, F.; Pistorio, A.; De Plaen, R.; Klein, G.; Seil, M.; Radinovic, R.; Reudink, R.; Dykowski, P.; Sȩkowski, M.; Próchniewicz, D.; Szpunar, R.; Mojzeš, M.; Jańk, J.; Papčo, J.; Engfeldt, A.; Olsson, P. A.; Smith, V.; van Westrum, D.; Ellis, B.; Lucero, B.

    2017-01-01

    In the framework of the regional EURAMET.M.G-K2 comparison of absolute gravimeters, 17 gravimeters were compared in November 2015. Four gravimeters were from different NMIs and DIs, they were used to link the regional comparison to the CCM.G.K2 by means of linking converter. Combined least-squares adjustments with weighted constraint was used to determine KCRV. Several pilot solutions are presented and compared with the official solution to demonstrate influences of different approaches (e.g. definition of weights and the constraint) on results of the adjustment. In case of the official solution, all the gravimeters are in equivalence with declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral comparison of 1 V and 10 V standards between the DEFNAT (Tunisia) and the BIPM February to March 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Ben Salah, B.; Mallat, A.; Abene, L.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Electrique, DEFNAT (Tunisia), was carried out from February to March 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMC (ZC) and BIPM6 (Z6), were transported by freight to DEFNAT and back to BIPM. In order to keep the Zeners powered during their transportation phase, a BIPM in-house voltage stabiliser was connected in parallel to the internal battery. The voltage stabiliser consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for 10 consecutive days. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DEFNAT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT, UDEFNAT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 26th of February 2016. UDEFNAT - UBIPM = + 0.07 μV uc = 0.04 μV, at 1.018 V UDEFNAT - UBIPM = + 0.38 μV uc = 0.10 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  15. KEY COMPARISON: Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Giera, Janine; Fraga, Isabel C.; Tønnes Jakobsen, Pia; Jensen, Hans D.; Hyllested, Peter; Karpov, Oleg; Kutovoy, Viatcheslav; Nakamura, Susumu; Vospelova, Alena; Zvezdina, Valentina

    2008-01-01

    CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were 15 °C, 25 °C, 37 °C. CCQM-K9.2, CCQM-K.9 and the first supplementary comparison CCQM-K9.1 [5] are activities of the Electrochemical Working Group (EAWG) of the CCQM. All three comparisons were coordinated by the PTB, Germany. The Danish Primary Laboratory (DPL) successfully took part in the CCQM-K9. Meanwhile the primary set-up for pH in Denmark moved from DPL affiliated to Radiometer Medical to DFM, Denmark. The subsequent comparison allows assessing the degree of equivalence for the measurement of pH at DFM after the move. Due to the interest of other laboratories in demonstrating their progress in pH measurements on the primary level the CCQM-K9.2 supplementary comparison was extended to other participants than DFM, namely NMIJ, VNIIFTRI, INMETRO and CMI. The reported quantity for CCQM-K9.2 was not the pH of the sample but the acidity function at zero chloride molality (see chapter 12). To calculate the pH value from the acidity function it is necessary to know the ionic strength of the sample buffer solution, which was undisclosed by the coordinator. With the exception of the Czech Metrology Institute, CMI, good agreement in the determined acidity function is found between the participants. The results reported by DFM and by PTB agree within their measurement uncertainty at all measurement temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report

  16. Audio-visual speech intelligibility benefits with bilateral cochlear implants when talker location varies.

    PubMed

    van Hoesel, Richard J M

    2015-04-01

    One of the key benefits of using cochlear implants (CIs) in both ears rather than just one is improved localization. It is likely that in complex listening scenes, improved localization allows bilateral CI users to orient toward talkers to improve signal-to-noise ratios and gain access to visual cues, but to date, that conjecture has not been tested. To obtain an objective measure of that benefit, seven bilateral CI users were assessed for both auditory-only and audio-visual speech intelligibility in noise using a novel dynamic spatial audio-visual test paradigm. For each trial conducted in spatially distributed noise, first, an auditory-only cueing phrase that was spoken by one of four talkers was selected and presented from one of four locations. Shortly afterward, a target sentence was presented that was either audio-visual or, in another test configuration, audio-only and was spoken by the same talker and from the same location as the cueing phrase. During the target presentation, visual distractors were added at other spatial locations. Results showed that in terms of speech reception thresholds (SRTs), the average improvement for bilateral listening over the better performing ear alone was 9 dB for the audio-visual mode, and 3 dB for audition-alone. Comparison of bilateral performance for audio-visual and audition-alone showed that inclusion of visual cues led to an average SRT improvement of 5 dB. For unilateral device use, no such benefit arose, presumably due to the greatly reduced ability to localize the target talker to acquire visual information. The bilateral CI speech intelligibility advantage over the better ear in the present study is much larger than that previously reported for static talker locations and indicates greater everyday speech benefits and improved cost-benefit than estimated to date.

  17. Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Zivkovic, V.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Directorate of Measures and Precious Metals (DMDM), Beograd, Serbia, was carried out from January to March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMA (ZA), were transported by freight to DMDM. At DMDM, the reference standard for DC voltage is a Josephson Voltage Standard. The output electromotive force of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DMDM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DMDM, at the level of 1.018 V and 10 V, at DMDM, UDMDM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 13 February 2014. UDMDM - UBIPM = 0.094 µV uc = 0.072 µV, at 1 V UDMDM - UBIPM = 0.39 µV uc = 0.12 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DMDM, based on KJ-90, and the uncertainty related to the comparison. The results at the 10 V level are not covered by the uncertainties with a coverage factor of 2. After the distribution of the Draft A, the DMDM discovered that the pressure gauge was defective. Some considerations on the correction to apply on the comparison result and the corresponding uncertainties are presented in the report. Nevertheless, the above results fully cover the CMCs of DMDM which are significantly larger. No corrections for temperature and pressure are applied in calibrations for

  18. Final report on COOMET.EM-S11: Supplementary bilateral comparison of the measurement of current transformers between UNIIM and PTB

    NASA Astrophysics Data System (ADS)

    Mohns, Enrico; Sychev, Y.; Roeissle, G.

    2014-01-01

    A bilateral comparison of the measurement of current transformers was carried out between UNIIM (Russia) and PTB (Germany). For all of the current ratio error measurements and the phase displacement measurements there is a close agreement between PTB and UNIIM. Extensive measurements with the travelling standards were carried out at 18 different current ratios and at 5 different test points (1%, 5%, 20%, 100% and 120%) each. The range of tested primary currents was from 10 mA to 60 kA. It can therefore be concluded that the results of each laboratory agree very well within the calculated measurement uncertainties. No outliers were observed. Considering especially the En factors, the calculated uncertainties seem to be too conservative to some extent. Here there is the possibility to slightly improve the uncertainty budgets in the future if there is a need. The worst En factors are within ±0.6 at 1 kA/5 A and ±0.8 at 3 kA. The current comparator 'IW 32' from PTB may have caused that. This was subsequently confirmed. The primary current induced a small voltage in the compensation winding. This problem has now been solved. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report of the key comparison APMP.QM-K91: APMP comparison on pH measurement of phthalate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Ketrin, Rosi; Nuryatini; Thanh, Ngo Huy; Truong Chinh, Nguyen; Vospelova, Alena; Bastkowski, Frank; Sander, Beatrice; Matzke, Jessica; Prokunin, Sergey; Frolov, Dmitry; Aprelev, Alexey; Dobrovolskiy, Vladimir; Uysal, Emrah; Liv, Lokman; Velina Lara-Manzano, Judith; Montero-Ruiz, Jazmin; Ortiz-Aparicio, JosÉ Luis; Ticona Canaza, Galia; Anuar Mohd Amin, Khirul; Abd Kadir, Haslina; Bakovets, Nickolay; Wong, Siu-Kay; Lam, Wai-Hing

    2017-01-01

    The APMP.QM-K91 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phthalate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan at the APMP-TCQM meeting held September 22-23, 2014. After approval by TCQM, the comparison has been conducted by NMIJ. The comparison is a key comparison following CCQM-K91. The comparison material was a phthalate buffer of pH around 4.0 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the third APMP key comparison on pH measurement and the fifth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006, APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011 and APMP.QM-K19/APMP.QM-P25 (a borate buffer) in 2013-2014. The results can be used further by any participant to support its CMC claim at least for a phthalate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Final report of the key comparison APMP.QM-K9: APMP comparison on pH measurement of phosphate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Ohata, Masaki; Cherdchu, Chainarong; Tangpaisarnkul, Nongluck

    2011-01-01

    The APMP.QM-K9 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phosphate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan, NMIJ, and the National Institute of Metrology of Thailand, NIMT, in August 2009. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K9, CCQM-K9.1 and CCQM-K9.2. The comparison material was a phosphate buffer of pH around 6.86 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the first APMP key comparison on pH measurement and the third APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004 and APMP.QM-P09 (a phthalate buffer) in 2006. The results can be used further by any participant to support its CMC claim for a phosphate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the temperature(s) used or the full temperature range between 15 °C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    PubMed

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Subsequent bilateral comparison to CCT-K3, CIPM key comparison CCT-K3.1: Comparison of standard platinum resistance thermometers at the triple point of water (T = 273.16 K) and at the melting point of gallium (T = 302.9146 K)

    NASA Astrophysics Data System (ADS)

    Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.

    2011-01-01

    A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Joung, W.; Gam, K. S.; Achmadi, A.; Trisna, B. A.

    2016-01-01

    The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Bilateral comparison of 1 V and 10 V standards between the NMISA (South Africa) and the BIPM April to June 2017 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Matlejoane, A. M.; Magagula, L.; Stock, M.

    2018-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the National Metrology Institute of South Africa, NMISA (South Africa), was carried out from April to June 2017. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPMB (ZB), were transported by freight to NMISA and back to BIPM. In order to keep the Zeners powered during their transportation phase, a voltage stabilizer developed by BIPM was connected in parallel to the internal battery. It consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for ten consecutive days. At NMISA, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NMISA, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NMISA, at the level of 1.018 V and 10 V, at NMISA, UNMISA, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference dates of the 19th and 18th of May 2017, respectively. UNMISA - UBIPM = + 0.07 μV uc = 0.02 μV, at 1.018 V UNMISA - UBIPM = + 0.001 μV uc = 0.34 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NMISA, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  6. KEY COMPARISON: Final report of comparison of the calibrations of hydrometers for liquid density determination between SIM laboratories: SIM.M.D-K4

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar

    2009-01-01

    This SIM comparison on the calibration of high accuracy hydrometers was carried out within fourteen laboratories in the density range from 600 kg/m3 to 1300 kg/m3 in order to evaluate the degree of equivalence among participant laboratories. This key comparison anticipates the planned key comparison CCM.D-K4, and is intended to be linked with CCM.D-K4 when results are available. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. Directional bilateral filters for smoothing fluorescence microscopy images

    NASA Astrophysics Data System (ADS)

    Venkatesh, Manasij; Mohan, Kavya; Seelamantula, Chandra Sekhar

    2015-08-01

    Images obtained through fluorescence microscopy at low numerical aperture (NA) are noisy and have poor resolution. Images of specimens such as F-actin filaments obtained using confocal or widefield fluorescence microscopes contain directional information and it is important that an image smoothing or filtering technique preserve the directionality. F-actin filaments are widely studied in pathology because the abnormalities in actin dynamics play a key role in diagnosis of cancer, cardiac diseases, vascular diseases, myofibrillar myopathies, neurological disorders, etc. We develop the directional bilateral filter as a means of filtering out the noise in the image without significantly altering the directionality of the F-actin filaments. The bilateral filter is anisotropic to start with, but we add an additional degree of anisotropy by employing an oriented domain kernel for smoothing. The orientation is locally adapted using a structure tensor and the parameters of the bilateral filter are optimized for within the framework of statistical risk minimization. We show that the directional bilateral filter has better denoising performance than the traditional Gaussian bilateral filter and other denoising techniques such as SURE-LET, non-local means, and guided image filtering at various noise levels in terms of peak signal-to-noise ratio (PSNR). We also show quantitative improvements in low NA images of F-actin filaments.

  8. CCQM-K103 key comparison melanine in milk powder

    NASA Astrophysics Data System (ADS)

    Li, Xiuqin; Zhang, Qinghe; Li, Hongmei; Li, Mengwan; Wong, Siu-kay; Lee, Foo-Wing; Kakoulides, Elias; Naujaus, Evaldas; Fernandes-Whaley, Maria; Prevoo-Franzsen, Des; Quinn, Laura; Pookrod, Preeyaporn; Konopelko, Leonid

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K103, was coordinated by the National Institute of Metrology (NIM) and Government Laboratory, Hong Kong, China (GLHK). The comparison was designed to demonstrate NMIs/DIs ability to analyze traces of melamine in milk and milk powder at concentration levels resulting from requirements for food safety. Seven NMIs or DIs participated in the comparison. Final reference value (KCRV) is 0.286 mg/kg, with standard uncertainty of the median as 0.011 mg/kg (3.8 %). The k-factor for the estimation of the expanded uncertainty was chosen as k = 2.57 ( t (0.05;5) ), thus the expanded uncertainty is 0.028 mg/kg (9.8%). The degrees of equivalence with melamine in milk powder KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for IDMS in determining mass fractions in the range from 0.1 to 5.0 mg/kg of analytes with low molar mass (range 50-300 Da) with high polarity (pKow > -2.0) in milk and milk products. Extension to other analytes and matrices should be applied with care since there is a close linkage to other relevant parameters as e.g. sample preparation procedures (liquid/liquid extraction, SPE clean-up) and analytical separation techniques (e.g., GC-MS, LC-MS/MS etc). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Simultaneous bilateral cataract surgery: economic analysis; Helsinki Simultaneous Bilateral Cataract Surgery Study Report 2.

    PubMed

    Leivo, Tiina; Sarikkola, Anna-Ulrika; Uusitalo, Risto J; Hellstedt, Timo; Ess, Sirje-Linda; Kivelä, Tero

    2011-06-01

    To present an economic-analysis comparison of simultaneous and sequential bilateral cataract surgery. Helsinki University Eye Hospital, Helsinki, Finland. Economic analysis. Effects were estimated from data in a study in which patients were randomized to have bilateral cataract surgery on the same day (study group) or sequentially (control group). The main clinical outcomes were corrected distance visual acuity, refraction, complications, Visual Function Index-7 (VF-7) scores, and patient-rated satisfaction with vision. Health-care costs of surgeries and preoperative and postoperative visits were estimated, including the cost of staff, equipment, material, floor space, overhead, and complications. The data were obtained from staff measurements, questionnaires, internal hospital records, and accountancy. Non-health-care costs of travel, home care, and time were estimated based on questionnaires from a random subset of patients. The main economic outcome measures were cost per VF-7 score unit change and cost per patient in simultaneous versus sequential surgery. The study comprised 520 patients (241 patients included non-health-care and time cost analyses). Surgical outcomes and patient satisfaction were similar in both groups. Simultaneous cataract surgery saved 449 Euros (€) per patient in health-care costs and €739 when travel and paid home-care costs were included. The savings added up to €849 per patient when the cost of lost working time was included. Compared with sequential bilateral cataract surgery, simultaneous bilateral cataract surgery provided comparable clinical outcomes with substantial savings in health-care and non-health-care-related costs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. KEY COMPARISON: Final Report on CCT-K7: Key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Stock, M.; Solve, S.; del Campo, D.; Chimenti, V.; Méndez-Lango, E.; Liedberg, H.; Steur, P. P. M.; Marcarino, P.; Dematteis, R.; Filipe, E.; Lobo, I.; Kang, K. H.; Gam, K. S.; Kim, Y.-G.; Renaot, E.; Bonnier, G.; Valin, M.; White, R.; Dransfield, T. D.; Duan, Y.; Xiaoke, Y.; Strouse, G.; Ballico, M.; Sukkar, D.; Arai, M.; Mans, A.; de Groot, M.; Kerkhof, O.; Rusby, R.; Gray, J.; Head, D.; Hill, K.; Tegeler, E.; Noatsch, U.; Duris, S.; Kho, H. Y.; Ugur, S.; Pokhodun, A.; Gerasimov, S. F.

    2006-01-01

    accepted this recommendation and the next edition of the SI brochure will include this specification. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. Comparison of two fertility-sparing approaches for bilateral borderline ovarian tumours: a randomized controlled study.

    PubMed

    Palomba, S; Zupi, E; Russo, T; Falbo, A; Del Negro, S; Manguso, F; Marconi, D; Tolino, A; Zullo, F

    2007-02-01

    During the childbearing years, the standard fertility-sparing treatment for bilateral borderline ovarian tumours (BOTs) is the unilateral oophorectomy plus controlateral cystectomy. The aim of the present study was to compare the effects of two laparoscopic fertility-sparing surgical procedures for the treatment of bilateral BOTs on recurrence and fertility in young women who desire to conceive as soon as possible. Thirty-two women affected by bilateral early-stage BOTs who desired to conceive were randomized to receive bilateral cystectomy (experimental group, n=15) or oophorectomy plus controlateral cystectomy (control group, n=17). At the first recurrence after childbearing completion, each patient was treated with non-conservative standard treatment. Recurrences and reproductive events were recorded. After a follow-up period of 81 months (19 inter-quartile; 60-96 range), the cumulative pregnancy rate (CPR) (14/15 versus 9/17; P=0.003) and the cumulative probability of first pregnancy (P= 0.011) were significantly higher in the experimental than in control group. No significant (P=0.358) difference between groups was detected in cumulative probability of first recurrence. The laparoscopic bilateral cystectomy followed by non-conservative treatment performed at the first recurrence after the childbearing completion is an effective surgical strategy for patients with bilateral early-stage BOTs who desire to conceive as soon as possible.

  12. Simultaneous bilateral decortications via video-assisted thoracic surgery for bilateral empyema

    PubMed Central

    Nose, Naohiro; Anami, Toshiki

    2014-01-01

    Introduction Bilateral empyema is a rare and life-threatening condition that is difficult to treat. We herein report a case of bilateral empyema that was treated with simultaneous bilateral decortications via video-assisted thoracic surgery (VATS). Presentation of case A 38-year-old female complained of chest pain, dyspnea, and high grade fever lasting two weeks. Computed tomography revealed bilateral notching pleural effusion and pneumonia with atelectasis. Bilateral thoracic drainage was performed. From the right chest, white pus was drained, and Streptococcus anginosus was identified. The left drainage fluid was serous, and no bacteria were identified. We diagnosed the patient with right empyema and left para-pneumonic effusion consequent to pneumonia. Because conservative therapies could not resolve the inflammatory findings, simultaneous bilateral VATS decortications were performed. Both thoracic cavities had loculated pleural effusion. In contrast to the preoperative findings, white pus was found in not only the right, but also the left thoracic cavity. She had an uncomplicated postoperative course and recovered. Discussion Bilateral empyema that has developed to the fibrinopleural phase is difficult to treat with drains alone. Bilateral VATS decortications helped to make a definitive diagnosis and treat both sides simultaneously. Conclusion Simultaneous bilateral VATS decortications should be considered as a feasible and effective procedure for bilateral empyema that is refractory to medical treatment. PMID:25528031

  13. Comparison of ablation centration after bilateral sequential versus simultaneous LASIK.

    PubMed

    Lin, Jane-Ming; Tsai, Yi-Yu

    2005-01-01

    To compare ablation centration after bilateral sequential and simultaneous myopic LASIK. A retrospective randomized case series was performed of 670 eyes of 335 consecutive patients who had undergone either bilateral sequential (group 1) or simultaneous (group 2) myopic LASIK between July 2000 and July 2001 at the China Medical University Hospital, Taichung, Taiwan. The ablation centrations of the first and second eyes in the two groups were compared 3 months postoperatively. Of 670 eyes, 274 eyes (137 patients) comprised the sequential group and 396 eyes (198 patients) comprised the simultaneous group. Three months post-operatively, 220 eyes of 110 patients (80%) in the sequential group and 236 eyes of 118 patients (60%) in the simultaneous group provided topographic data for centration analysis. For the first eyes, mean decentration was 0.39 +/- 0.26 mm in the sequential group and 0.41 +/- 0.19 mm in the simultaneous group (P = .30). For the second eyes, mean decentration was 0.28 +/- 0.23 mm in the sequential group and 0.30 +/- 0.21 mm in the simultaneous group (P = .36). Decentration in the second eyes significantly improved in both groups (group 1, P = .02; group 2, P < .01). The mean distance between the first and second eyes was 0.31 +/- 0.25 mm in the sequential group and 0.32 +/- 0.18 mm in the simultaneous group (P = .33). The difference of ablation center angles between the first and second eyes was 43.2 < or = 48.3 degrees in the sequential group and 45.1 +/- 50.8 degrees in the simultaneous group (P = .42). Simultaneous bilateral LASIK is comparable to sequential surgery in ablation centration.

  14. Final report on EURAMET.M.P-S12 — Bilateral supplementary comparison of the national pressure standards of CMI and INRIM in the range 300 Pa to 15 kPa of negative gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajícek, Zdenek; Bergoglio, Mercede; Pražák, Dominik; Pasqualin, Stefano

    2014-01-01

    This report describes a EURAMET bilateral supplementary comparison between Czech CMI and Italian INRIM in low negative gauge pressure in gas (nitrogen), denoted as EURAMET.M.P-S12. The digital non-rotating pressure balance FPG8601 manufactured by Fluke/DH-Instruments, USA is normally used for gauge and absolute pressures in the range from 1 Pa to 15 kPa, but with some modifications it can be used also for the negative gauge pressures in the same range. During the preparation of the visit of INRIM at CMI for the last comparison within the framework of EURAMET.M.P-K4.2010, it was agreed to also perform an additional comparison in the range from 300 Pa to 15 kPa of negative gauge pressure. The measurements were performed in October 2012. Both institutes successfully proved their equivalence in all the tested points in the range from 300 Pa to 15 kPa of negative gauge pressure in a comparison that had, so far, been unique. . Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Linking results of key and supplementary comparisons of AC/DC voltage transfer references

    NASA Astrophysics Data System (ADS)

    Velychko, Oleh

    2018-04-01

    A regional key comparison (KC) COOMET.EM-K6.a and a supplementary comparison (SC) COOMET.EM-S1 of AC/DC voltage transfer references were conducted between participating laboratories from the Eurasian region. Measurements were made over the period 2004-2014. The results showed good agreement between all but one of the participating laboratories. The proposed procedure of linking results of key and SCs of regional metrology organization of AC/DC voltage transfer references is presented. Linking results is realized for COOMET.EM-K6.a and CCEM-K6.a KCs, and for COOMET.EM-K6.a KC and COOMET.EM-S1 SC.

  16. EURAMET.T-K7 Key Comparison of Water Triple-Point Cells

    NASA Astrophysics Data System (ADS)

    Peruzzi, A.; Bosma, R.; Kerkhof, O.; Rosenkranz, P.; Del Campo Maldonado, M. D.; Strnad, R.; Nielsen, J.; Anagnostou, M.; Veliki, T.; Zvizdic, D.; Grudnewicz, E.; Nedea, M.; Neagu, D. M.; Steur, P.; Filipe, E.; Lobo, I.; Antonsen, I.; Renaot, E.; Heinonen, M.; Weckstrom, T.; Bojkovski, J.; Turzo-Andras, E.; Nemeth, S.; White, M.; Tegeler, E.; Dobre, M.; Duris, S.; Kartal Dogan, A.; Uytun, A.; Augevicius, V.; Pauzha, A.; Pokhodun, A.; Simic, S.

    2011-12-01

    The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the "mother" comparison CCT-K7 is discussed in detail.

  17. Quantitative assessment of paretic limb dexterity and interlimb coordination during bilateral arm rehabilitation training.

    PubMed

    Xu, Chang; Li, Siyi; Wang, Kui; Hou, Zengguang; Yu, Ningbo

    2017-07-01

    In neuro-rehabilitation after stroke, the conventional constrained induced movement therapy (CIMT) has been well-accepted. Existing bilateral trainings are mostly on mirrored symmetrical motion. However, complementary bilateral movements are dominantly involved in activities of daily living (ADLs), and functional bilateral therapies may bring better skill transfer from trainings to daily life. Neurophysiological evidence is also growing. In this work, we firstly introduce our bilateral arm training system realized with a haptic interface and a motion sensor, as well as the tasks that have been designed to train both the manipulation function of the paretic arm and coordination of bilateral upper limbs. Then, we propose quantitative measures for functional assessment of complementary bilateral training performance, including kinematic behavior indices, smoothness, submovement and bimanual coordination. After that, we describe the experiments with healthy subjects and the results with respect to these quantitative measures. Feasibility and sensitivity of the proposed indices were evaluated through comparison of unilateral and bilateral training outcomes. The proposed bilateral training system and tasks, as well as the quantitative measures, have been demonstrated effective for training and assessment of unilateral and bilateral arm functions.

  18. Final report of the SIM.QM-S8 supplementary comparison, trace metals in drinking water

    NASA Astrophysics Data System (ADS)

    Yang, Lu; Nadeau, Kenny; Gedara Pihillagawa, Indu; Meija, Juris; Mester, Zoltan; Napoli, Romina; Pérez Zambra, Ramiro; Ferreira, Elizabeth; Alejandro Ahumada Forigua, Diego; Abella Gamba, Johanna Paola

    2018-01-01

    After completing a supplementary comparison SIM.QM-S7, the National Metrology Institute of Colombia (NMIC) requested to National Research Council of Canada (NRC) a subsequent bilateral comparison, because INMC considered that its results in SIM.QM-S7 unrepresentative of its standards. In this context, NRC agreed to coordinate this bilateral comparison with the aim of demonstrating the measurement capabilities of trace elements in fresh water. Participants included NMIC and LATU. No measurement method was prescribed by the coordinating laboratory. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S8 Supplementary Comparison provides NMIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    PubMed

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  20. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    PubMed Central

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity. PMID:26175916

  1. Computerized mass detection in whole breast ultrasound images: reduction of false positives using bilateral subtraction technique

    NASA Astrophysics Data System (ADS)

    Ikedo, Yuji; Fukuoka, Daisuke; Hara, Takeshi; Fujita, Hiroshi; Takada, Etsuo; Endo, Tokiko; Morita, Takako

    2007-03-01

    The comparison of left and right mammograms is a common technique used by radiologists for the detection and diagnosis of masses. In mammography, computer-aided detection (CAD) schemes using bilateral subtraction technique have been reported. However, in breast ultrasonography, there are no reports on CAD schemes using comparison of left and right breasts. In this study, we propose a scheme of false positive reduction based on bilateral subtraction technique in whole breast ultrasound images. Mass candidate regions are detected by using the information of edge directions. Bilateral breast images are registered with reference to the nipple positions and skin lines. A false positive region is detected based on a comparison of the average gray values of a mass candidate region and a region with the same position and same size as the candidate region in the contralateral breast. In evaluating the effectiveness of the false positive reduction method, three normal and three abnormal bilateral pairs of whole breast images were employed. These abnormal breasts included six masses larger than 5 mm in diameter. The sensitivity was 83% (5/6) with 13.8 (165/12) false positives per breast before applying the proposed reduction method. By applying the method, false positives were reduced to 4.5 (54/12) per breast without removing a true positive region. This preliminary study indicates that the bilateral subtraction technique is effective for improving the performance of a CAD scheme in whole breast ultrasound images.

  2. KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Comparison of bimodal and bilateral cochlear implant users on speech recognition with competing talker, music perception, affective prosody discrimination, and talker identification.

    PubMed

    Cullington, Helen E; Zeng, Fan-Gang

    2011-02-01

    Despite excellent performance in speech recognition in quiet, most cochlear implant users have great difficulty with speech recognition in noise, music perception, identifying tone of voice, and discriminating different talkers. This may be partly due to the pitch coding in cochlear implant speech processing. Most current speech processing strategies use only the envelope information; the temporal fine structure is discarded. One way to improve electric pitch perception is to use residual acoustic hearing via a hearing aid on the nonimplanted ear (bimodal hearing). This study aimed to test the hypothesis that bimodal users would perform better than bilateral cochlear implant users on tasks requiring good pitch perception. Four pitch-related tasks were used. 1. Hearing in Noise Test (HINT) sentences spoken by a male talker with a competing female, male, or child talker. 2. Montreal Battery of Evaluation of Amusia. This is a music test with six subtests examining pitch, rhythm and timing perception, and musical memory. 3. Aprosodia Battery. This has five subtests evaluating aspects of affective prosody and recognition of sarcasm. 4. Talker identification using vowels spoken by 10 different talkers (three men, three women, two boys, and two girls). Bilateral cochlear implant users were chosen as the comparison group. Thirteen bimodal and 13 bilateral adult cochlear implant users were recruited; all had good speech perception in quiet. There were no significant differences between the mean scores of the bimodal and bilateral groups on any of the tests, although the bimodal group did perform better than the bilateral group on almost all tests. Performance on the different pitch-related tasks was not correlated, meaning that if a subject performed one task well they would not necessarily perform well on another. The correlation between the bimodal users' hearing threshold levels in the aided ear and their performance on these tasks was weak. Although the bimodal cochlear

  4. [Bilateral cochlear implants].

    PubMed

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  5. Final report on key comparison CCQM-K100: Analysis of copper in ethanol

    NASA Astrophysics Data System (ADS)

    Zhou, Tao; Kakoulides, Elias; Zhu, Yanbei; Jaehrling, Reinhard; Rienitz, Olaf; Saxby, David; Phukphatthanachai, Pranee; Yafa, Charun; Labarraque, Guillaume; Cankur, Oktay; Can, Süleyman Z.; Konopelko, Leonid A.; Kustikov, Yu A.; Caciano de Sena, Rodrigo; Marques Rodrigues, Janaina; Fonseca Sarmanho, Gabriel; Fortunato de Carvalho Rocha, Werickson; dos Reis, Lindomar Augusto

    2014-01-01

    The increase in renewable sources in the energy matrix of the countries is an effort to reduce dependency on crude oil and the environmental impacts associated with its use. In order to help overcome the lack of widely accepted quality standards for fuel ethanol and to guarantee its competitiveness in the international trade market, the NMIs have been working to develop certified reference materials for bio-fuels and measurement methods. Inorganic impurities such as Cu, Na and Fe may be present in the fuel ethanol and their presence is associated with corrosion and the formation of oxide deposits in some engine parts. The key comparison CCQM-K100 was carried out under the auspices of the Inorganic Analysis Working Group (IAWG) and the coordination of the National Institute of Metrology, Quality and Technology (INMETRO). The objective of this key comparison was to compare the measurement capabilities of the participants for the determination of Cu in fuel ethanol. Ten NMIs participated in this exercise and most of them used the isotopic dilution method for determining the amount of Cu. The median was chosen as key comparison reference value (KCRV). The assigned KCRV for the Cu content was 0.3589 µg/g with a combined standard uncertainty of 0.0014 µg/g. In general, there is a good agreement among the participants' results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. KEY COMPARISON: CCQM-K25: Determination of PCB congeners in sediment

    NASA Astrophysics Data System (ADS)

    Schantz, Michele; Wise, Stephen

    2004-01-01

    Polychlorinated biphenyls (PCBs) consist of 209 possible congeners depending on the substitution of the chlorine atoms around the biphenyl molecule. PCBs have been widely used as industrial fluids, flame retardants, diluents, hydraulic fluids, and dielectric fluids for capacitors and transformers. As a class of compounds, they are environmentally stable and tend to bioaccumulate. Of the 209 possible congeners, approximately 150 congeners have been reported in the environment. Congener-specific PCB methods, which are typically based on gas chromatography (GC) with electron capture detection (ECD) or mass spectrometric (MS) detection, are designed to measure selected priority congeners, but the congeners of interest change with the study and sponsoring agency. A pilot study (CCQM-P17) for the determination of PCB congeners in sediment was organized by NIST and NRC-Canada in 2000. Ten laboratories participated in the pilot study. After discussion and critical review of the data, there was agreement that the pilot study should be followed by a Key Comparison and that the Key Comparison Reference Value (KCRV) should be derived from isotope dilution GC/MS (ID-GC/MS) based methods that had been validated in the Pilot Study. The CCQM-K25 Key Comparison study utilized a sediment sample prepared by mixing known quantities of two sediment materials to simulate a moderately contaminated sample with respect to PCBs. Nine laboratories participated in CCQM-K25 and demonstrated a high level of equivalence in capabilities for determining five PCB congeners (congener numbers 28, 101, 105, 153, and 170) in a moderately contaminated sediment using GC/MS-based methods. The amount of substance concentration for the congeners measured ranged from ~10 ng/g to ~35 ng/g. The relative expanded uncertainties of the KCRVs ranged from 2% to 5%, indicating excellent agreement among the participants that used ID-GC/MS. Results from the one laboratory that used GC/MS with a non-labeled PCB

  7. Final report on the torque key komparison CCM.T-K1.2 measurand torque: 0 N.m, 500 N.m, 1000 N.m

    NASA Astrophysics Data System (ADS)

    Röske, Dirk

    2015-01-01

    The purpose of the CIPM subsequent bilateral comparison CCM.T-K1.2 was to link another participant, namely the National Institute of Metrology (Thailand), in short NIMT, to the CCM.T-K1 torque key comparison. The measuring capabilities up to 1000 N.m of dead-weight torque standard machines with supported lever were investigated. The pilot laboratory was the same in both comparisons—it was the Physikalisch-Technische Bundesanstalt (PTB, Braunschweig, Germany). The same two very stable torque transducers with well-known properties were used as travelling standards. The measurements at the participating laboratory were carried out between November 2007 and February 2008. According to the technical protocol, torque steps of 500 N.m and 1000 N.m had to be measured both in clockwise and anticlockwise directions. Corrections had to be applied to the results reported by the participants taking into account the use of different amplifiers, the creep (due to different loading times of the machines) and the environmental conditions in the laboratories (temperature and relative humidity of the ambient air). The results of the pilot laboratory in this bilateral comparison are in very good agreement with the same results obtained in the CCM.T-K1 comparison. For each of the transducers, the two torque steps and both senses of direction of the torque vector, the key comparison reference value of the CCM.T-K1 was taken, and the results of participant NIMT were calculated with respect to these values. The agreement between the results is very good. The smallest expanded (k = 2) relative uncertainty of the machine stated by the participant is 1 × 10-4. The results of the comparison support this uncertainty statement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according

  8. Final report on EURAMET.M.P-K4.2010: Key and supplementary comparison of national pressure standards in the range 1 Pa to 15 kPa of absolute and gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajíček, Zdeněk; Bergoglio, Mercede; Jousten, Karl; Otal, Pierre; Sabuga, Wladimir; Saxholm, Sari; Pražák, Dominik; Vičar, Martin

    2014-01-01

    This report describes a EURAMET comparison of five European National Metrology Institutes in low gauge and absolute pressure in gas (nitrogen), denoted as EURAMET.M.P-K4.2010. Its main intention is to state equivalence of the pressure standards, in particular those based on the technology of force-balanced piston gauges such as e.g. FRS by Furness Controls, UK and FPG8601 by DHI-Fluke, USA. It covers the range from 1 Pa to 15 kPa, both gauge and absolute. The comparison in absolute mode serves as a EURAMET Key Comparison which can be linked to CCM.P-K4 and CCM.P-K2 via PTB. The comparison in gauge mode is a supplementary comparison. The comparison was carried out from September 2008 till October 2012. The participating laboratories were the following: CMI, INRIM, LNE, MIKES, PTB-Berlin (absolute pressure 1 kPa and below) and PTB-Braunschweig (absolute pressure 1 kPa and above and gauge pressure). CMI was the pilot laboratory and provided a transfer standard for the comparison. This transfer standard was also the laboratory standard of CMI at the same time, which resulted in a unique and logistically difficult star comparison. Both in gauge and absolute pressures all the participating institutes successfully proved their equivalence with respect to the reference value and all also proved mutual bilateral equivalences in all the points. All the participating laboratories are also equivalent with the reference values of CCM.P-K4 and CCM.P-K2 in the relevant points. The comparison also proved the ability of FPG8601 to serve as a transfer standard. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report on key comparison CCQM-K81: Chloramphenicol in pig muscle

    NASA Astrophysics Data System (ADS)

    Polzer, Joachim; Henrion, Andre; Gowik, Petra

    2013-01-01

    Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K81 'Chloramphenicol in pig muscle', was coordinated by BVL and PTB in 2009/2010. Six NMIs/DIs participated in this comparison. Chloramphenicol (CAP) is an effective broad-spectrum antibiotic which can in principle be used for the treatment of humans and animals. Its use for the treatment of food-producing animals is, however, forbidden worldwide in many countries due to potential severe side effects. The key comparison was the follow-up to the successful pilot study 'CCQM-P90: chloramphenicol in milk'. With this key comparison it was intended to demonstrate the capability of NMIs/DIs to analyse traces of CAP in food at concentration levels resulting from legal requirements for food control. Additionally, the quality of this kind of analysis with respect to compliance with legal requirements for food control methods and the international comparability of measurements should be evaluated in general. The study was classified as a 'track C' study (studies in emerging areas of global interest). For the study incurred lyophilised pig muscle material containing CAP (at a mass-fraction level around the maximum allowable level for import for a number of countries) has been produced as a candidate reference material by BVL and IRMM (Institute for Reference Materials and Measurements, JRC of the European Commission). Animal treatment and slaughtering of the animal to gain incurred muscle material as well as pre-testing of the CAP content was done at the BVL. The IRMM did further processing of the material and testing of homogeneity and stability. Participants were invited to assign the mass fraction of free CAP in the comparison sample. CCQM-K81 demonstrated successfully the capability of the participating laboratories to assign chloramphenicol values in tissue down to residue levels of around 0.3 ng/g (referring to the

  10. Clinical and logopaedic results of simultaneous and sequential bilateral implants in children with severe and/or profound bilateral sensorineural hearing loss: A literature review.

    PubMed

    López-Torrijo, Manuel; Mengual-Andrés, Santiago; Estellés-Ferrer, Remedios

    2015-06-01

    This article carries out a literature review of the advantages and limitations of the simultaneous bilateral cochlear implantation (SCI) compared to those of the sequential bilateral cochlear implantation (SBCI) and the unilateral cochlear implantation (UCI). The variables analysed in said comparison are: safety and surgical technique, SCI incidence, effectiveness, impact of the inter-implant interval, costs and financing, impact on brain plasticity, impact on speech and language development, main benefits, main disadvantages and concerns, and predictive factors of prognosis. Although the results are not conclusive, all variables analysed seem to point towards observable benefits of SCI in comparison with SBCI or UCI. This tendency should be studied in more depth in multicentre studies with higher methodological rigour, more comprehensive samples and periods and other determining variables (age at the time of implantation, duration and degree of the hearing loss, rehabilitation methodologies used, family involvement, etc.). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. CCQM key comparison CCQM-K75: Determination of toxic metals in algae

    NASA Astrophysics Data System (ADS)

    Shakhashiro, A.; Toervenyi, A.; Gaudino, S.; Rosamilia, S.; Belli, M.; Turk, G. C.

    2011-01-01

    The determination of mass fraction of toxic elements and especially platinum emitted from automobile catalytic converters in the air is a critical factor in assessing air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to toxic elements. Biomonitors, such as lichen and algae, are examples of environmental samples that have been widely used by the scientific community to assess and monitor the level of environmental pollution. For this purpose, the IAEA-450 algae material containing heavy metals and platinum at low level was prepared by IAEA Seibersdorf Laboratories in collaboration with the Italian National Institute for Environmental Protection—ISPRA (former APAT). During the April meeting in 2009 of the Inorganic Analysis Working Group (IAWG) of the CCQM it was agreed to organize a key comparison K75 for Pt and Ni and a parallel pilot study P118 for As, Cd, Cr, Hg, Ni, Pb and Pt using this algae material. The key comparison CCQM-K75 was successfully organized. The participating NMIs demonstrated a high level of measurement capabilities and technical competence in analysing nickel and platinum at a low level of concentration in environmental samples such as algae. The between-laboratories reproducibility standard deviation for nickel and platinum was 1.9% and 3.6% respectively, which reflects an excellent agreement of between-laboratories measurement results. The ratio between the bias and its expanded uncertainty for nickel and platinum was below 2.0 for all reported results except in one case. This study was a practical demonstration of a CCQM comparison to use the 'core-capabilities' utilized by participants as a mean of providing evidence for Calibration and Measurement Capabilities (CMC) claims for Ni and Pt. Based on this CCQM international key comparison, the measurement capability of the NMIs which participated in the CCQM-K75 has been demonstrated directly for determination of Pt and Ni

  12. KEY COMPARISON: Report on the Regional Comparison COOMET.AUV.A-K3

    NASA Astrophysics Data System (ADS)

    Barrera-Figueroa, Salvador; Nielsen, Lars; Rasmussen, Knud

    2007-01-01

    COOMET.AUV.A-K3 is a Regional Comparison that supplements the Key Comparison CCAUV.A-K3 organized by the CCAUV. The participating NMIs are GUM (Poland), INM (Romania), VNIIFTRI (Russia) and DP-NDI 'Systema' (Ukraine). The role of Pilot laboratory was undertaken by DPLADFM (Denmark). The measurements took place between May 2005 and February 2006. The time schedule was organized in a single star configuration. Initially, two LS2aP microphones were circulated. However, a sudden change of sensitivity of one of them forced the inclusion of an additional microphone. Nevertheless, the analysis was performed on all microphones involved. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignation of degrees of equivalence and the link to the CCAUV.A-K3. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    PubMed

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  14. Comparison APMP.QM-S2.1: oxygen in nitrogen at atmospheric level

    NASA Astrophysics Data System (ADS)

    Kim, B. M.; Kim, K.; Jung, J.; Oh, S.; Hui, L.; Li, H.; Keat, T. B.; Ann, C. H.

    2016-01-01

    This document describes results of the bilateral comparison of an oxygen in nitrogen gas mixture. The nominal amount-of-substance fraction was 0.2 mol/mol oxygen in nitrogen Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Allisy-Roberts, P. J.; Burns, D. T.; Guerra, A. S.; Laitano, R. F.; Pimpinella, M.

    2010-01-01

    A comparison of the standards for absorbed dose to water of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI), and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation under the auspices of the key comparison BIPM.RI(I)-K4. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the ENEA and the BIPM standards for absorbed dose to water, is 0.9999 (0.0044). The present 2007 result replaces the earlier ENEA value in this key comparison. The degrees of equivalence between the ENEA and the other participants in this comparison have been calculated and the results are given in the form of a matrix for the ten national metrology institutes (NMIs) that have published results in this ongoing comparison for absorbed dose to water. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Key comparison CCPR-K1.a as an interlaboratory comparison of correlated color temperature

    NASA Astrophysics Data System (ADS)

    Kärhä, P.; Vaskuri, A.; Pulli, T.; Ikonen, E.

    2018-02-01

    We analyze the results of spectral irradiance key comparison CCPR-K1.a for correlated color temperature (CCT). For four participants out of 13, the uncertainties of CCT, calculated using traditional methods, not accounting for correlations, would be too small. The reason for the failure of traditional uncertainty calculation is spectral correlations, producing systematic deviations of the same sign over certain wavelength regions. The results highlight the importance of accounting for such correlations when calculating uncertainties of spectrally integrated quantities.

  17. Final report on EUROMET key comparison EUROMET.M.D-K2 (EUROMET 627) "Comparison of density determinations of liquid samples"

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Heinonen, Martti; Gosset, André; Zelenka, Zoltán; Lorefice, Salvatore; Hellerud, Kristen; Durlik, Hanna; Jordaan, Werner; Field, Ireen

    2016-01-01

    The results of the key comparison EUROMET 627 (EUROMET.M.D-K2) are presented. This project covered the density measurements of three liquids: dodecane, water and an oil of high viscosity measured at 15 °C, 20 °C and 40 °C. Seven European metrology laboratories and the South African laboratory CSIR-NML (now: NMISA) measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards between 04 October 2001 and 18 December 2001. The stability and homogeneity of the liquids were investigated by the pilot laboratory PTB. The results generally show good agreement among the participants. Only for the simple Mohr-Westphal balances do the uncertainties seem to be underestimated by the laboratories. Furthermore, the measurement of high-viscosity oil was difficult for some laboratories. Nevertheless, the five laboratories PTB/DE, BNM/FR (now: LNE/FR), OMH/HU (now: MKEH/HU), IMGC/IT (now: INRIM/IT) and GUM/PL agree with each other for stated uncertainties of 0.05 kg/m3 or less. This satisfies the current needs of customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. No reference values were calculated since the subsequent CCM key comparison CCM.D-K2 had a different scope and the EUROMET 627 comparison was soon superseded by the EURAMET 1019 (EURAMET.M.D-K2) comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on COOMET Vickers PTB/VNIIFTRI key comparison (COOMET.M.H-K1.b and COOMET.M.H-K1.c)

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Herrmann, K.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales of two National Metrology Institutes—PTB and VNIIFTRI. The pilot laboratory was PTB, which was the linking institute with the key comparison reference values of CCM.H-K1. In the key comparison two sets of hardness reference blocks for the Vickers hardness scales HV1 and HV30, each consisting of three hardness reference blocks with the hardness levels 240 HV, 540 HV and 840 HV, are used. The same hardness reference blocks were used previously in the key comparison CCM.H-K1. The measurement results and uncertainty assessments, announced by VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Comparison of EMG activity on abdominal muscles during plank exercise with unilateral and bilateral additional isometric hip adduction.

    PubMed

    Kim, Soo-Yong; Kang, Min-Hyeok; Kim, Eui-Ryong; Jung, In-Gui; Seo, Eun-Young; Oh, Jae-Seop

    2016-10-01

    The aim of this study was to investigate the effects of additional isometric hip adduction during the plank exercise on the abdominal muscles. Twenty healthy young men participated in this study. Surface electromyography (EMG) was used to monitor the activity of the bilateral rectus abdominis (RA), the internal oblique (IO), and the external oblique (EO) muscles. The participants performed three types of plank exercise; the standard plank exercise, the plank exercise with bilateral isometric hip adduction, and the plank exercise with unilateral isometric hip adduction. All abdominal muscle activity was significantly increased during the plank exercise combined with the bilateral and unilateral isometric hip adduction compared with the standard plank exercise (p<0.05). Bilateral IO, EO, and left RA muscle activity was significantly increased during the unilateral isometric hip adduction compared with the bilateral isometric hip adduction (p<0.05). These findings suggest that additional isometric hip adduction during the plank exercise could be a useful method to enhance abdominal muscle activity. In particular, the unilateral isometric hip adduction is a more beneficial exercise than the bilateral isometric hip adduction. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Laparoscopic inguinal hernia repair: gold standard in bilateral hernia repair? Results of more than 2800 patients in comparison to literature.

    PubMed

    Wauschkuhn, Constantin Aurel; Schwarz, Jochen; Boekeler, Ulf; Bittner, Reinhard

    2010-12-01

    Advantages and disadvantages of open and endoscopic hernia surgery are still being discussed. Until now there has been no study that evaluated the advantages and disadvantages of bilateral hernia repair in a large number of patients. Our prospectively collected database was analyzed to compare the results of laparoscopic bilateral with laparoscopic unilateral hernia repair. We then compared these results with the results of a literature review regarding open and laparoscopic bilateral hernia repair. From April 1993 to December 2007 there were 7240 patients with unilateral primary hernia (PH) and 2880 patients with bilateral hernia (5760 hernias) who underwent laparoscopic transabdominal preperitoneal patch plastic (TAPP). Of the 10,120 patients, 28.5% had bilateral hernias. Adjusted for the number of patients operated on, the mean duration of surgery for unilateral hernia repair was shorter than that for bilateral repair (45 vs. 70 min), but period of disability (14 vs. 14 days) was the same. Adjusted for the number of hernias repaired, morbidity (1.9 vs. 1.4%), reoperation (0.5 vs. 0.43%), and recurrence rate (0.63 vs. 0.42%) were similar for unilateral versus bilateral repair, respectively. The review of the literature shows a significantly shorter time out of work after laparoscopic bilateral repair than after the bilateral open approach. Simultaneous laparoscopic repair of bilateral inguinal hernias does not increase the risk for the patient and has an equal length of down time compared with unilateral repair. According to literature, recovery after laparoscopic repair is faster than after open simultaneous repair. Laparoscopic/endoscopic inguinal hernia repair of bilateral hernias should be recommended as the gold standard.

  1. ARE UNILATERAL AND BILATERAL KNEE OSTEOARTHRITIS PATIENTS UNIQUE SUBSETS OF KNEE OSTEOARTHRITIS? A BIOMECHANICAL PERSPECTIVE

    PubMed Central

    Messier, Stephen P.; Beavers, Daniel P.; Herman, Cassandra; Hunter, David J.; DeVita, Paul

    2016-01-01

    Objective To compare the gait of adults with unilateral and bilateral symptomatic and radiographic knee osteoarthritis (OA) to determine whether these subgroups can be treated similarly in the clinic and when recruiting for randomized clinical trials, and to use these data to generate future hypotheses regarding gait in these subsets of knee OA patients. Methods Cross-sectional investigation of patients with unilateral and bilateral knee OA on gait mechanics using 136 older adults (age ≥ 55 yrs.; 27 kg.m−2 ≥ BMI ≤ 41 kg.m−2; 82% female) with radiographic knee OA. Comparisons were made between the most affected side of the bilateral group (Bi) and the affected side of the unilateral group (Uni), and between symmetry indices of each group. Results There were no significant differences in any temporal, kinematic, or kinetic measures between the Uni and Bi cohorts. Comparison of symmetry indices between groups also revealed no significant differences. Conclusion The similarity in lower extremity mechanics between unilateral and bilateral knee OA patients is sufficiently robust to consider both subsets as a single cohort. We hypothesize that biomechanical adaptations to knee OA are at least partially systemic in origin and not based solely on the physiological characteristics of an affected knee joint. PMID:26706699

  2. Bilaterally cleft lip, limb defects, and haematological manifestations: Roberts syndrome versus TAR syndrome.

    PubMed

    Urban, M; Opitz, C; Bommer, C; Enders, H; Tinschert, S; Witkowski, R

    1998-09-23

    We report on a 13-year-old patient followed since birth. He is the only offspring of young, non-consanguineous German parents. His mother has an isolated left cleft of lip and a cleft palate. At birth, our patient presented with bilaterally cleft lip/cleft palate, phocomelia of upper limbs with normal hands, and mild symmetrical deficiencies of the long bones of the lower limbs. Haematological evaluation demonstrated a leukaemoid reaction during a urinary tract infection as well as intermittent thrombocytopenia and episodes of marked eosinophilia during the first two years of life. Intellectual development has been normal. Comparison with two similar cases from the literature suggests a non-random phenotypic overlap of Roberts syndrome (MIM 268300) and TAR syndrome (MIM 274000). Such clinical constellations may be key observations to understand the genetic relationship of Roberts syndrome and TAR syndrome in future phenotype-genotype correlations.

  3. Final report on APMP.M.P-S3: Results of the supplementary comparison in gas media in the range 1.77 MPa to 6.8 MPa

    NASA Astrophysics Data System (ADS)

    Owen, N.; Bergoglio, M.

    2013-01-01

    This report provides the results of the supplementary bilateral comparison APMP.M.P-S3 between NMI Australia (NMIA) and INRIM, Italy executed from November 2010 to November 2011. NMIA acted as the pilot laboratory and provided a Ruska G series piston gauge as the transfer standard, with a nominal area 16.8 mm2 requiring a nominal load of 12 kg to balance a pressure of 7.0 MPa. The purpose of this supplementary bilateral comparison was to provide data for linking NMIA to CCM.P-K1.c in the pressure range greater than 4 MPa to extend the range covered by key comparison APMP.M.P-K1c. The original protocol called for the pressure range from 80 kPa to 6.80 MPa. Both participants agreed to limit this comparison range to 1.77 MPa to 6.50 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on key comparison COOMET.QM-K36 (Project COOMET 540/UA/11) 'Electrolytic Conductivity 0,5 S/m'

    NASA Astrophysics Data System (ADS)

    Gavrilkin, V.; Prokopenko, L.; Bakovec, N.; Zolotorevich, E.; Suvorov, V.; Ovchinnikov, Yu; Pilishvili, T.; Buleishvili, M.; Zhasanbaeva, B.; Aytzhatova, G.; Ticona, G.; Vyskocil, L.

    2015-01-01

    The COOMET.QM-K36 key comparison 'Electrolytic conductivity: 0.5 S/m' is a comparison in the field of electrolytic conductivity measurements conducted by COOMET and carried out in 2012. It used a solution of KCl in water and the results are connected to those of the CCQM key comparison CCQM-K36.a through common participation of VNIIFTRI (Russia), SMU (Slovakia) and Ukrmetrteststandart (Ukraine). The purpose of this key comparison was to establish the equivalence of measurements of electrolytic conductivity performed at the National Metrology Institutes of COOMET member states for the value of 0.5 S/m. The results can be used to support the CMCs claims over the range of 0.1 S/m to 1.3 S/m. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral metal stents for hilar biliary obstruction using a 6Fr delivery system: outcomes following bilateral and side-by-side stent deployment.

    PubMed

    Law, Ryan; Baron, Todd H

    2013-09-01

    Controversy exists on optimal endoscopic management for palliation of malignant hilar obstruction, with advocates for metal "side-by-side" (SBS) and "stent-in-stent" (SIS) techniques. We sought to evaluate the technical feasibility, efficacy, and outcomes of bilateral biliary self-expanding metal stents (SEMS) for treatment of malignant hilar obstruction using a stent with a 6Fr delivery system. This was a single-center, retrospective review of all patients who underwent bilateral placement of Zilver® biliary SEMS for malignant hilar obstruction from January 2010 to August 2012. Patients underwent endoscopic retrograde cholangiopancreatography with placement of stents using either the SIS or SBS stent techniques. Twenty-four patients (19 men, mean age 63 years) underwent bilateral stenting for malignant hilar obstruction during the study period. Seventeen and seven patients underwent the SBS and SIS technique, respectively. Cholangiocarcinoma (n=14) was the most common cause of hilar obstruction. Initial technical success was achieved in 24/24 (100%) of patients; however, 12 (50%) patients required re-intervention during the study period (median 98 days). Comparison of the SBS and SIS groups revealed no statistical difference with respect to need for re-intervention (P=0.31), successful re-intervention (P=0.60), or procedural length (P=0.89). Use of bilateral Zilver® SEMS in either the SBS or SIS configuration is safe, technically feasible, and effective for drainage of malignant hilar obstruction; however, duration of stent patency and procedure-free survival remain variable.

  6. Consensus building for interlaboratory studies, key comparisons, and meta-analysis

    NASA Astrophysics Data System (ADS)

    Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza

    2017-06-01

    Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian

  7. Final report on CIPM key comparison CCM.FF-K6.2011: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John

    2014-01-01

    The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Comparisons of absolute gravimeters (COOMET.M.G-S1)

    NASA Astrophysics Data System (ADS)

    Vinnichenko, Mr Alexander; Germak, Alessandro, Dr

    2017-01-01

    This report describes the results of the RMO supplementary comparison COOMET.M.G-S1 (also known as bilateral comparison COOMET 634/UA/14). The comparison measurements between the two participants NSC 'IM' (pilot laboratory) and INRIM were started in December 2015 and finished in January 2016. Participants of comparisons were conducted at their national standards the measurements of the free fall acceleration in gravimetric point laboratory of absolute gravimetry of INRIM named INRiM.2. Absolute measurements of gravimetric acceleration were conducted by ballistic gravimeters. The agreement between the two participants is good. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Diversity of bilateral synaptic assemblies for binaural computation in midbrain single neurons.

    PubMed

    He, Na; Kong, Lingzhi; Lin, Tao; Wang, Shaohui; Liu, Xiuping; Qi, Jiyao; Yan, Jun

    2017-11-01

    Binaural hearing confers many beneficial functions but our understanding of its underlying neural substrates is limited. This study examines the bilateral synaptic assemblies and binaural computation (or integration) in the central nucleus of the inferior colliculus (ICc) of the auditory midbrain, a key convergent center. Using in-vivo whole-cell patch-clamp, the excitatory and inhibitory postsynaptic potentials (EPSPs/IPSPs) of single ICc neurons to contralateral, ipsilateral and bilateral stimulation were recorded. According to the contralateral and ipsilateral EPSP/IPSP, 7 types of bilateral synaptic assemblies were identified. These include EPSP-EPSP (EE), E-IPSP (EI), E-no response (EO), II, IE, IO and complex-mode (CM) neurons. The CM neurons showed frequency- and/or amplitude-dependent EPSPs/IPSPs to contralateral or ipsilateral stimulation. Bilateral stimulation induced EPSPs/IPSPs that could be larger than (facilitation), similar to (ineffectiveness) or smaller than (suppression) those induced by contralateral stimulation. Our findings have allowed our group to characterize novel neural circuitry for binaural computation in the midbrain. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Bilateral Patellar Tendon Rupture

    DTIC Science & Technology

    2009-07-01

    Bilateral patellar tendon rupture Military Medicine Radiology Corner, Volume 173, July, 2009...Radiology Corner Bilateral patellar tendon rupture (#37) Guarantor: 2dLt Ramon A. Riojas, USAF, MSC1 Contributors: 2dLt Ramon A. Riojas...with the abbreviated answer in the July 2009 issue. 1 The authors present a case of bilateral patellar tendon rupture in an active duty male exiting

  11. Bilateral vision loss in a captive cheetah (Acinonyx jubatus).

    PubMed

    Walser-Reinhardt, Ladina; Wernick, Morena B; Hatt, Jean-Michel; Spiess, Bernhard M

    2010-09-01

    The following case report describes a 1-year-old female cheetah (Acinonyx jubatus) with bilateral blindness and unresponsive pupils. For comparison, a second healthy 2.5-year-old male cheetah without visual deficits was also examined. Clinical examination of both animals included biomicroscopy, indirect ophthalmoscopy, tonometry, and electroretinography. The young female cheetah showed no menace response, no direct or indirect pupillary light reflex, and no dazzle reflex in either eye. Fundus lesions, as detected by indirect ophthalmoscopy, are described for the female animal. In both eyes, the fundus color was green/turquoise/yellow with multiple hyperpigmented linear lesions in the tapetal area around the optic nerve. The optic nerve head was dark gray and about half the normal size suggesting bilateral optic nerve hypoplasia and retinal dysplasia or differentially optic nerve atrophy and chorioretinal scarring. The ERG had low amplitudes in the right eye but appeared normal in the left eye compared with the male cheetah. Blood levels did not suggest current taurine deficiency. This is addressed to some degree in the discussion. Bilateral optic nerve hypoplasia or optic nerve atrophy is a rare anomaly in cats and has not yet been described in a cheetah.

  12. Pilot Study EURAMET.AUV.V-P1: Bilateral comparison on magnitude of the complex charge sensitivity of accelerometers from 10 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Bartoli, Claire; Hermawanto, Denny

    2017-01-01

    The results of a Pilot Study EURAMET.AUV.V-P1 between LNE (France) and RCM-LIPI (Indonesia) are reported. This bilateral comparison of sinusoidal vibration was organized after the implementation of various improvements at RCM-LIPI following a previous (unpublished) comparison that had revealed discrepancies in their results at frequencies above 5 kHz. The results of this Pilot Study, using the same accelerometers as the earlier comparison, demonstrate that the discrepancies at high frequencies have been resolved. For both the back-to-back and the single-ended accelerometers tested, the sensitivities of the RCM-LIPI and the LNE over the frequency range from 10 Hz to 10 kHz now agree within their declared uncertainties. Main text To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV.

  13. Bilateral comparison on electric field measurements between TÜBİTAK UME and SASO NMCC

    NASA Astrophysics Data System (ADS)

    Aslan, Çağlar; Alrobaish, Abdullah M.; Şen, Osman

    2017-01-01

    Electromagnetic (EM) probes are widely utilized in the measurement of EM fields for non-ionizing radiation, electromagnetic compatibility (EMC) testing and other applications in the frequency range 5 Hz-60 GHz. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as IEEE 1309. The existing NMIs or emerging NMIs should refer to the international comparison measurements in order to assure the quality of their measurement results. Therefore, the electric field comparison measurements organized by TUBITAK UME were performed between TUBITAK UME and SASO NMCC at the 100 Hz, 1 kHz, 10 MHz, 100 MHz, 1 GHz, 10 GHz and 18 GHz frequencies in order to obtain the correction factors of the electric field probes. The comparison measurements were carried out in accordance with the Technical Protocol prepared by TUBITAK UME. The measurements started in October 2017 and were completed in January 2017. There was good agreement found for the correction factors. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. KEY COMPARISON Final report on APMP.EM-K6.a: APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty

    NASA Astrophysics Data System (ADS)

    Budovsky, Ilya

    2010-01-01

    The APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty, APMP.EM-K6a, started in 2000 and concluded in 2003. This comparison has offered the same range and frequencies as the key comparison CCEM-K6a with the view of providing the National Metrology Institutes (NMIs) of the APMP member economies with an opportunity to link the values of their standards for ac-dc transfer difference to the international reference values. The ac-dc difference of the travelling standard was measured with 3 V applied at standard frequencies of 1 kHz, 20 kHz, 100 kHz and 1 MHz, and optional frequencies of 50 kHz and 500 kHz. The travelling standard has not been damaged and has shown excellent stability. The results submitted by the overwhelming majority of the participants lie well within the reported uncertainty. At the standard frequencies the results have been linked to those of the CCEM-K6a key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. Final report on APMP.T-K7 key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Tsai, S. F.; White, R.; Tamba, J.; Yamazawa, K.; Ho, M. K.; Tsui, C. M.; Zaid, G.; Achmadi, A.; Gam, K. S.; Othman, H.; Ali, N. M.; Yuan, K. H.; Shaochun, Y.; Liedberg, H.; Yaokulbodee, C.

    2016-01-01

    APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. KEY COMPARISON: BIPM comparison BIPM.RI(II)-K1.Cu-64 of the activity measurements of the radionuclide 64Cu

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Kossert, K.; Nähle, O. J.

    2009-01-01

    In 2009, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted a sample of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The value of the activity submitted was about 9.3 MBq. The result of this new comparison has been approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), comparison identifier BIPM.RI(II)-K1.Cu-64. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Sequential Bilateral Cochlear Implantation in a Patient with Bilateral Meniere’s Disease

    PubMed Central

    Holden, Laura K.; Neely, J. Gail; Gotter, Brenda D.; Mispagel, Karen M.; Firszt, Jill B.

    2012-01-01

    This case study describes a 45 year old female with bilateral, profound sensorineural hearing loss due to Meniere’s disease. She received her first cochlear implant in the right ear in 2008 and the second cochlear implant in the left ear in 2010. The case study examines the enhancement to speech recognition, particularly in noise, provided by bilateral cochlear implants. Speech recognition tests were administered prior to obtaining the second implant and at a number of test intervals following activation of the second device. Speech recognition in quiet and noise as well as localization abilities were assessed in several conditions to determine bilateral benefit and performance differences between ears. The results of the speech recognition testing indicated a substantial improvement in the patient’s ability to understand speech in noise and her ability to localize sound when using bilateral cochlear implants compared to using a unilateral implant or an implant and a hearing aid. In addition, the patient reported considerable improvement in her ability to communicate in daily life when using bilateral implants versus a unilateral implant. This case suggests that cochlear implantation is a viable option for patients who have lost their hearing to Meniere’s disease even when a number of medical treatments and surgical interventions have been performed to control vertigo. In the case presented, bilateral cochlear implantation was necessary for this patient to communicate successfully at home and at work. PMID:22463939

  18. Bilateral tuberculous otitis media: An unique presentation.

    PubMed

    Bhatkar, Dhiraj; Utpat, Ketaki; Desai, Unnati; Joshi, Jyotsna M

    2017-10-01

    Tuberculous otitis media (TOM) is an uncustomary variety of tuberculosis (TB) usually seen secondary to pulmonary tuberculosis or associated with it. It is characterized by indolent and heterogeneous presentations. Diagnosis warrants clinical, radiological, and microbiological amalgamation. It is hence challenging and frequently delayed leading to disabling complications. Opportunate suspicion, timely diagnosis and appropriate antituberculosis therapy are the key to successful management. We report a unique case of bilateral TOM occurring in an immunocompetent adult. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  19. SUPPLEMENTARY COMPARISON: COOMET.RI(II)-S1.Rn-222 (169/UA/98): Rn-222 volume activity comparison

    NASA Astrophysics Data System (ADS)

    Skliarov, V.; Röttger, A.; Honig, A.; Korostin, S.; Kuznetsov, S.; Lapenas, A.; Milevsky, V.; Ivaniukovich, A.; Kharitonov, I.; Sepman, S.

    2009-01-01

    According to a first program, a supplementary comparison of Rn-222 volume activity was drawn up as a bilateral supplementary comparison between NSC 'Institute of Metrology', Ukraine, and VNIIFTRI, Russia. It took place in March 2005. In April 2005, at the 5th meeting of COOMET held in Braunschweig (Germany), representatives of these institutes exchanged data which showed the comparability of the national standards of Ukraine and Russia for the check points. During the discussion of the procedure some other institutes decided to join the comparison program, which was extended to BelGIM (Belarus), PTB (Germany), VNIIM (Russia) and RMTC (Latvia). The national standards of volume activity of radon-222 were thus calibrated using one standard radon radiometer as the transfer standard. Results are shown in the Final Report of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by COOMET, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. Comparison of Right and Left Upper Limb Arterial Variants in Patients Undergoing Bilateral Transradial Procedures.

    PubMed

    Burzotta, Francesco; Brancati, Marta Francesca; Porto, Italo; Saffioti, Silvia; Aurigemma, Cristina; Niccoli, Giampaolo; Leone, Antonio Maria; Coluccia, Valentina; Crea, Filippo; Trani, Carlo

    2015-12-01

    Transradial approach (TRA), when compared with transfemoral, improves the safety of percutaneous coronary procedures. Arterial axis variants are known to hinder the performance of transradial approach percutaneous coronary procedures. Data on the occurrence of arterial axis variants in the right and left arm arterial axes of individual patients are lacking. From a single-center prospective registry, we selected all patients in whom bilateral upper limb arterial anatomy was assessed based on the performance of left and right radial catheterization obtained during the same or during repeat coronary diagnostic or interventional procedure(s). The occurrence of upper right and left limb arterial axis variants was classified according to the previously described operative ABC classification. A total of 610 patients were identified. An ABC upper limb arterial axis variant was detected in 156 (25.6%) patients. Variants were right-sided only in 65 (11.0%), left-sided only in 40 (6.6%), and bilateral in 46 (7.5%) patients. Thus, arterial axis variants were significantly more common in the right side (P=0.02). Bilateral arterial variants were significantly associated with age, female sex, and valvulopathy. Both A (radial/brachial) and B (axillary/subclavian/innominate) variants exhibited concordance across the 2 sides (odds ratio, 7.2; 95% confidence interval, 4.1-12.7 and 8.0; 95% confidence interval, 2.1-30.9, respectively). The occurrence of an anatomic variant potentially hindering transradial approach coronary diagnostic or interventional procedures is bilateral in <8% of cases and is more common in the right arm. Such information may guide, during the clinical practice, the access selection in the case of repeat procedures or need for additional accesses. © 2015 American Heart Association, Inc.

  1. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Burns, D. T.; Berlyand, V.; Berlyand, A.

    2010-01-01

    A new comparison of the standards for absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation in 2009. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9976 for the calibration coefficients of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. This result is consistent with the earlier 2001 comparison result of 0.9967 (43). The updated degrees of equivalence for the VNIIFTRI are compared with those of the other national metrology institutes as presented in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Funding analysis of bilateral autologous free-flap breast reconstructions in Australia.

    PubMed

    Sinha, Shiba; Ruskin, Olivia; McCombe, David; Morrison, Wayne; Webb, Angela

    2015-08-01

    Bilateral breast reconstructions are being increasingly performed. Autologous free-flap reconstructions represent the gold standard for post-mastectomy breast reconstruction but are resource intensive. This study aims to investigate the difference between hospital reimbursement and true cost of bilateral autologous free-flap reconstructions. Retrospective analysis of patients who underwent bilateral autologous free-flap reconstructions at a single Australian tertiary referral centre was performed. Hospital reimbursement was determined from coding analysis. A true cost analysis was also performed. Comparisons were made considering the effect of timing, indication and complications of the procedure. Forty-six bilateral autologous free-flap procedures were performed (87 deep inferior epigastric perforators (DIEPs), four superficial inferior epigastric artery perforator flaps (SIEAs) and one muscle-sparing free transverse rectus abdominis myocutaneous flap (MS-TRAM)). The mean funding discrepancy between hospital reimbursement and actual cost was $12,137 ± $8539 (mean ± standard deviation (SD)) (n = 46). Twenty-four per cent (n = 11) of the cases had been coded inaccurately. If these cases were excluded from analysis, the mean funding discrepancy per case was $9168 ± $7453 (n = 35). Minor and major complications significantly increased the true cost and funding discrepancy (p = 0.02). Bilateral free-flap breast reconstructions performed in Australian public hospitals result in a funding discrepancy. Failure to be economically viable threatens the provision of this procedure in the public system. Plastic surgeons and hospital managers need to adopt measures in order to make these gold-standard procedures cost neutral. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Systematic Review of Bilateral Independent Periodic Discharges Written for Topical Journal Subject on Periodic Discharges.

    PubMed

    Freund, Brin; Kaplan, Peter W

    2018-05-01

    Periodic discharges (PDs) are EEG patterns that may have important clinical and prognostic implications. There are different subtypes of PDs that are delineated by their location, and each type may have different meaning regarding prognosis and clinical associations. Bilateral independent PDs are a subtype that have not been analyzed recently and remain poorly understood. In this article, we systematically review the literature to better describe bilateral independent PDs regarding underlying neuropathology, neuroimaging, and neuroexamination correlates, seizure incidence, EEG characteristics, their comparison with other PD subtypes, and prognostic meaning.

  4. A case of bilateral aldosterone-producing adenomas differentiated by segmental adrenal venous sampling for bilateral adrenal sparing surgery

    PubMed Central

    Morimoto, R; Satani, N; Iwakura, Y; Ono, Y; Kudo, M; Nezu, M; Omata, K; Tezuka, Y; Seiji, K; Ota, H; Kawasaki, Y; Ishidoya, S; Nakamura, Y; Arai, Y; Takase, K; Sasano, H; Ito, S; Satoh, F

    2016-01-01

    Primary aldosteronism due to unilateral aldosterone-producing adenoma (APA) is a surgically curable form of hypertension. Bilateral APA can also be surgically curable in theory but few successful cases can be found in the literature. It has been reported that even using successful adrenal venous sampling (AVS) via bilateral adrenal central veins, it is extremely difficult to differentiate bilateral APA from bilateral idiopathic hyperaldosteronism (IHA) harbouring computed tomography (CT)-detectable bilateral adrenocortical nodules. We report a case of bilateral APA diagnosed by segmental AVS (S-AVS) and blood sampling via intra-adrenal first-degree tributary veins to localize the sites of intra-adrenal hormone production. A 36-year-old man with marked long-standing hypertension was referred to us with a clinical diagnosis of bilateral APA. He had typical clinical and laboratory profiles of marked hypertension, hypokalaemia, elevated plasma aldosterone concentration (PAC) of 45.1 ng dl−1 and aldosterone renin activity ratio of 90.2 (ng dl−1 per ng ml−1 h−1), which was still high after 50 mg-captopril loading. CT revealed bilateral adrenocortical tumours of 10 and 12 mm in diameter on the right and left sides, respectively. S-AVS confirmed excess aldosterone secretion from a tumour segment vein and suppressed secretion from a non-tumour segment vein bilaterally, leading to the diagnosis of bilateral APA. The patient underwent simultaneous bilateral sparing adrenalectomy. Histopathological analysis of the resected adrenals together with decreased blood pressure and PAC of 5.2 ng dl−1 confirmed the removal of bilateral APA. S-AVS was reliable to differentiate bilateral APA from IHA by direct evaluation of intra-adrenal hormone production. PMID:26538381

  5. KEY COMPARISON: Final report on CCEM key comparison CCEM.RF-K10.CL (GT-RF/99-2) 'Power in 50 Ω coaxial lines, frequency: 50 MHz to 26 GHz' measurement techniques and results

    NASA Astrophysics Data System (ADS)

    Janik, Dieter; Inoue, T.; Michaud, A.

    2006-01-01

    This report summarizes the results and the measuring methods of an international key comparison between twelve national metrology institutes (NMIs) and is concerning the calibration factor of RF power sensors in the coaxial 3.5 mm line for frequencies up to 26 GHz. Two RF power travelling standards fitted with male PC 3.5 mm connectors were measured at seven frequencies. The following NMIs participated: NMIJ (Japan), NRC (Canada), NIST (USA), METAS (Switzerland), CSIR-NML (South Africa), NMIA (Australia), NPL (UK), SiQ (Slovenia), IEN (Italy), VNIIFTRI (Russian Federation), SPRING (Singapore) and PTB (Germany), as the pilot laboratory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Hardware Implementation of a Bilateral Subtraction Filter

    NASA Technical Reports Server (NTRS)

    Huertas, Andres; Watson, Robert; Villalpando, Carlos; Goldberg, Steven

    2009-01-01

    A bilateral subtraction filter has been implemented as a hardware module in the form of a field-programmable gate array (FPGA). In general, a bilateral subtraction filter is a key subsystem of a high-quality stereoscopic machine vision system that utilizes images that are large and/or dense. Bilateral subtraction filters have been implemented in software on general-purpose computers, but the processing speeds attainable in this way even on computers containing the fastest processors are insufficient for real-time applications. The present FPGA bilateral subtraction filter is intended to accelerate processing to real-time speed and to be a prototype of a link in a stereoscopic-machine- vision processing chain, now under development, that would process large and/or dense images in real time and would be implemented in an FPGA. In terms that are necessarily oversimplified for the sake of brevity, a bilateral subtraction filter is a smoothing, edge-preserving filter for suppressing low-frequency noise. The filter operation amounts to replacing the value for each pixel with a weighted average of the values of that pixel and the neighboring pixels in a predefined neighborhood or window (e.g., a 9 9 window). The filter weights depend partly on pixel values and partly on the window size. The present FPGA implementation of a bilateral subtraction filter utilizes a 9 9 window. This implementation was designed to take advantage of the ability to do many of the component computations in parallel pipelines to enable processing of image data at the rate at which they are generated. The filter can be considered to be divided into the following parts (see figure): a) An image pixel pipeline with a 9 9- pixel window generator, b) An array of processing elements; c) An adder tree; d) A smoothing-and-delaying unit; and e) A subtraction unit. After each 9 9 window is created, the affected pixel data are fed to the processing elements. Each processing element is fed the pixel value for

  7. Comparative study between unilateral and bilateral cochlear implantation in children of 1 and 2 years of age.

    PubMed

    Escorihuela García, Vicente; Pitarch Ribas, María Ignacia; Llópez Carratalá, Ignacio; Latorre Monteagudo, Emilia; Morant Ventura, Antonio; Marco Algarra, Jaime

    2016-01-01

    The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localization and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducted a statistical comparison of both groups in the audiometry, IT-Mais, Nottingham, LittlEars scales and verbal tests. No significant differences in hearing thresholds and questionnaires between unilateral and bilateral implantation were detected in either the first or second year. Verbal tests do show statistically significant differences: children with bilateral cochlear implant obtain 100% recognition of disyllabic and phrases within 2-3 years after implantation whilst children with one implant do not obtain those results at 5 years after surgery. No differences between simultaneous and sequential bilateral implantation were detected. We emphasize the importance of ensuring good early audiological screening, to carry out an early and bilateral cochlear implantation with the consequent development of audio-language skills similar to normal hearing children. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  8. A Comparison of Right Unilateral and Sequential Bilateral Repetitive Transcranial Magnetic Stimulation for Major Depression: A Naturalistic Clinical Australian Study.

    PubMed

    Galletly, Cherrie A; Carnell, Benjamin L; Clarke, Patrick; Gill, Shane

    2017-03-01

    A great deal of research has established the efficacy of repetitive transcranial magnetic stimulation (rTMS) in the treatment of depression. However, questions remain about the optimal method to deliver treatment. One area requiring consideration is the difference in efficacy between bilateral and unilateral treatment protocols. This study aimed to compare the effectiveness of sequential bilateral rTMS and right unilateral rTMS. A total of 135 patients participated in the study, receiving either bilateral rTMS (N = 57) or right unilateral rTMS (N = 78). Treatment response was assessed using the Hamilton depression rating scale. Sequential bilateral rTMS had a higher response rate than right unilateral (43.9% vs 30.8%), but this difference was not statistically significant. This was also the case for remission rates (33.3% vs 21.8%, respectively). Controlling for pretreatment severity of depression, the results did not indicate a significant difference between the protocols with regard to posttreatment Hamilton depression rating scale scores. The current study found no statistically significant differences in response and remission rates between sequential bilateral rTMS and right unilateral rTMS. Given the shorter treatment time and the greater safety and tolerability of right unilateral rTMS, this may be a better choice than bilateral treatment in clinical settings.

  9. Idiopathic bilateral male breast abscess.

    PubMed

    Sinha, Rajan Kumar; Sinha, Mithilesh Kumar; Gaurav, Kumar; Kumar, Amar

    2014-03-10

    A 38-year-old man presented with bilateral breast swelling, along with pain and redness for 7 days. Bilateral axillary nodes were also palpable; which were multiple and discrete. A provisional diagnosis of bilateral breast abscess was made with suspicion of underlying malignancy. Incision and drainage through subareolar incision was performed and the adjoining tissue was excised and sent for histopathological examination.

  10. Motor Experience Reprograms Development of a Genetically-Altered Bilateral Corticospinal Motor Circuit.

    PubMed

    Serradj, Najet; Martin, John H

    Evidence suggests that motor experience plays a role in shaping development of the corticospinal system and voluntary motor control, which is a key motor function of the system. Here we used a mouse model with conditional forebrain deletion of the gene for EphA4 (Emx1-Cre:EphA4tm2Kldr), which regulates development of the laterality of corticospinal tract (CST). We combined study of Emx1-Cre:EphA4tm2Kldr with unilateral forelimb constraint during development to expand our understanding of experience-dependent CST development from both basic and translational perspectives. This mouse develops dense ipsilateral CST projections, a bilateral motor cortex motor representation, and bilateral motor phenotypes. Together these phenotypes can be used as readouts of corticospinal system organization and function and the changes brought about by experience. The Emx1-Cre:EphA4tm2Kldr mouse shares features with the common developmental disorder cerebral palsy: bilateral voluntary motor impairments and bilateral CST miswiring. Emx1-Cre:EphA4tm2Kldr mice with typical motor experiences during development display the bilateral phenotype of "mirror" reaching, because of a strongly bilateral motor cortex motor representation and a bilateral CST. By contrast, Emx1-Cre:EphA4tm2Kldr mice that experienced unilateral forelimb constraint from P1 to P30 and tested at maturity had a more contralateral motor cortex motor representation in each hemisphere; more lateralized CST projections; and substantially more lateralized/independent reaching movements. Changes in CST organization and function in this model can be explained by reduced synaptic competition of the CST from the side without developmental forelimb motor experiences. Using this model we show that unilateral constraint largely abrogated the effects of the genetic mutation on CST projections and thus demonstrates how robust and persistent experience-dependent development can be for the establishment of corticospinal system

  11. KEY COMPARISON: Final report of the CCQM-K56: Ca, Fe, Zn and Cu in whole fat soybean powder

    NASA Astrophysics Data System (ADS)

    Liandi, Ma; Qian, Wang

    2010-01-01

    The CCQM-K56 key comparison was organized by the Inorganic Analysis Working Group (IAWG) of CCQM as a follow-up to completed pilot study CCQM-P64 to test the abilities of national metrology institutes to measure the amount content of nutritious elements in whole fat soybean powder. A pilot study CCQM-P64.1 was conducted in parallel with this key comparison. The National Institute of Metrology (NIM), P. R. China, acted as the coordinating laboratory. Eleven NIMs participated in CCQM-K56. Four elements - Ca, Fe, Zn and Cu - in different concentration levels have been studied. Different measurement methods (IDMS, ICP-MS, ICP-OES, AAS and INAA) and the microwave digestion method were used. The agreement of the results of CCQM-K56 is very good, and obviously better than that of the original P64. It shows that the capability of all of the participants had been promoted from the original pilot study to this key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. Specific Changes in Young Soccer Player's Fitness After Traditional Bilateral vs. Unilateral Combined Strength and Plyometric Training.

    PubMed

    Ramirez-Campillo, Rodrigo; Sanchez-Sanchez, Javier; Gonzalo-Skok, Oliver; Rodríguez-Fernandez, Alejandro; Carretero, Manuel; Nakamura, Fabio Y

    2018-01-01

    The aim of this study was to compare changes in young soccer player's fitness after traditional bilateral vs. unilateral combined plyometric and strength training. Male athletes were randomly divided in two groups; both received the same training, including strength training for knee extensors and flexors, in addition to horizontal plyometric training drills. The only difference between groups was the mode of drills technique: unilateral (UG; n = 9; age, 17.3 ± 1.1 years) vs. bilateral (TG; n = 9; age, 17.6 ± 0.5 years). One repetition maximum bilateral strength of knee muscle extensors (1RM_KE) and flexors (1RM_KF), change of direction ability (COD), horizontal and vertical jump ability with one (unilateral) and two (bilateral) legs, and limb symmetry index were measured before and after an 8-week in-season intervention period. Some regular soccer drills were replaced by combination of plyometric and strength training drills. Magnitude-based inference statistics were used for between-group and within-group comparisons. Beneficial effects ( p < 0.05) in 1RM_KE, COD, and several test of jumping performance were found in both groups in comparison to pre-test values. The limb symmetry index was not affected in either group. The beneficial changes in 1RM_KE (8.1%; p = 0.074) and 1RM_KF (6.7%; p = 0.004), COD (3.1%; p = 0.149), and bilateral jump performance (from 2.7% [ p = 0.535] to 10.5% [ p = 0.002]) were possible to most likely beneficial in the TG than in the UG. However, unilateral jump performance measures achieved likely to most likely beneficial changes in the UG compared to the TG (from 4.5% [ p = 0.090] to 8.6% [ p = 0.018]). The improvements in jumping ability were specific to the type of jump performed, with greater improvements in unilateral jump performance in the UG and bilateral jump performance in the TG. Therefore, bilateral strength and plyometric training should be complemented with unilateral drills, in order to maximize adaptations.

  13. Specific Changes in Young Soccer Player's Fitness After Traditional Bilateral vs. Unilateral Combined Strength and Plyometric Training

    PubMed Central

    Ramirez-Campillo, Rodrigo; Sanchez-Sanchez, Javier; Gonzalo-Skok, Oliver; Rodríguez-Fernandez, Alejandro; Carretero, Manuel; Nakamura, Fabio Y.

    2018-01-01

    The aim of this study was to compare changes in young soccer player's fitness after traditional bilateral vs. unilateral combined plyometric and strength training. Male athletes were randomly divided in two groups; both received the same training, including strength training for knee extensors and flexors, in addition to horizontal plyometric training drills. The only difference between groups was the mode of drills technique: unilateral (UG; n = 9; age, 17.3 ± 1.1 years) vs. bilateral (TG; n = 9; age, 17.6 ± 0.5 years). One repetition maximum bilateral strength of knee muscle extensors (1RM_KE) and flexors (1RM_KF), change of direction ability (COD), horizontal and vertical jump ability with one (unilateral) and two (bilateral) legs, and limb symmetry index were measured before and after an 8-week in-season intervention period. Some regular soccer drills were replaced by combination of plyometric and strength training drills. Magnitude-based inference statistics were used for between-group and within-group comparisons. Beneficial effects (p < 0.05) in 1RM_KE, COD, and several test of jumping performance were found in both groups in comparison to pre-test values. The limb symmetry index was not affected in either group. The beneficial changes in 1RM_KE (8.1%; p = 0.074) and 1RM_KF (6.7%; p = 0.004), COD (3.1%; p = 0.149), and bilateral jump performance (from 2.7% [p = 0.535] to 10.5% [p = 0.002]) were possible to most likely beneficial in the TG than in the UG. However, unilateral jump performance measures achieved likely to most likely beneficial changes in the UG compared to the TG (from 4.5% [p = 0.090] to 8.6% [p = 0.018]). The improvements in jumping ability were specific to the type of jump performed, with greater improvements in unilateral jump performance in the UG and bilateral jump performance in the TG. Therefore, bilateral strength and plyometric training should be complemented with unilateral drills, in order to maximize adaptations. PMID:29623049

  14. Magnetic resonance mammography in comparison with mammography in the discovery of multifocal, multicentric and bilateral lesions of breast cancer.

    PubMed

    Bakhtavar, Khadijeh; Saran, Maryam; Behzadifar, Masoud; Farsi, Maryam

    2017-08-01

    Breast cancer is one of the health system problems and important diseases that is rising in developing and advanced countries. This study aimed to determine the difference of Magnetic Resonance Mammography (MRM) findings versus mammography in detecting multifocal, multi-centric and malignant bilateral lesions in patients with known breast cancer in Tehran. This cross-sectional study was conducted in Iran and Tehran among breast cancer patients between January 2015 and February 2016. Patients were included in the study prior to surgery, at the request of a surgeon with the aim of detecting multifocal, multi-centric and bilateral lesions. Demographic information was also collected from patients. The results for quantitative variables were expressed as mean and standard deviations, and for qualitative variables, were expressed as relative and absolute frequency. Chi-square test was used to compare the two methods. SPSS Ver.24 (IBM) software was used to analyze the data. Thirty-nine patients were enrolled in the study. The mean age of patients in this study was 48.46±6.836. In mammography, 13 (33.3%) had Composition C and 26 (66.7%) had Composition D according to the type of Composition. In total, 25 patients (89.3%) had one lesion and 3 patients (10.7%) had more than two lesions. In MRM, all lesions observed were mass (54 masses). The number of lesions found in MRM was 27 patients with one lesion (58.9%), 6 patients with two lesions (20.5%) and 5 patients with three lesions (20.6%). MRM detected more lesions compared to mammography (p<0.0001). The value of Chi-square test with a degree of freedom and error level of 0.05 was 3.71 and p<0.0001 that showed a significant relationship between the number of MRM findings in comparison with mammography. The results of our study showed that two or more lesions and bilateral lesions in MRM were more than mammography in women with B Breast Composition C, D; the findings showed that MRM has a better ability to detect breast

  15. Idiopathic bilateral male breast abscess

    PubMed Central

    Sinha, Rajan Kumar; Sinha, Mithilesh Kumar; Gaurav, Kumar; Kumar, Amar

    2014-01-01

    A 38-year-old man presented with bilateral breast swelling, along with pain and redness for 7 days. Bilateral axillary nodes were also palpable; which were multiple and discrete. A provisional diagnosis of bilateral breast abscess was made with suspicion of underlying malignancy. Incision and drainage through subareolar incision was performed and the adjoining tissue was excised and sent for histopathological examination. PMID:24614823

  16. Comparison of measurement standards of the acoustic pressure in air in the low frequency range: COOMET.AUV.A-K2

    NASA Astrophysics Data System (ADS)

    Chalyy, V.

    2011-01-01

    A bilateral regional comparison of national microphone standards from 2 Hz to 250 Hz was carried out between the DP NDI 'Systema' (Ukraine) and the VNIIFTRI (Russia) from July to September 2009. The comparison, COOMET.AUV.A-K2, was based on the pressure calibration of laboratory standard microphones type LSIP. The comparison results have been linked to the established key comparison reference value (KCRV) of CCAUV.A-K2. The degrees of equivalence, expressed as the deviation from the established KCRV and its expanded uncertainty (k = 2), have been determined, and the comparison result is in agreement with the KCRV within the estimated uncertainties at all employed frequencies. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Final report on the key comparison CCM.P-K4.2012 in absolute pressure from 1 Pa to 10 kPa

    NASA Astrophysics Data System (ADS)

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Bilateral Endoscopic Medial Maxillectomy for Bilateral Inverted Papilloma

    PubMed Central

    Kodama, Satoru; Kawano, Toshiaki; Suzuki, Masashi

    2012-01-01

    Inverted papilloma (IP) is a benign tumor of the nasal cavity and paranasal sinuses that is unilateral in most cases. Bilateral IP, involving both sides of the nasal cavity and sinuses, is extremely rare. This paper describes a large IP that filled in both sides of the nasal cavity and sinuses, mimicking association with malignancy. The tumor was successfully treated by bilateral endoscopic medial maxillectomy (EMM). The patient is without evidence of the disease 24 months after surgery. If preoperative diagnosis does not confirm the association with malignancy in IP, endoscopic sinus surgery (ESS) should be selected, and ESS, including EMM, is a good first choice of the treatment for IP. PMID:22953103

  19. Bilateral Internal Carotid Artery Occlusion, External Carotid Artery Stenosis, and Vertebral Artery Kinking: May It Be Asymptomatic?

    PubMed

    Fatic, Nikola; Jaffer, Usman; Ivana, Saicic; Gordana, Globarevic-Vukcevic; Markovic, Dragan; Kostic, Dusan; Davidovic, Lazar

    2017-10-01

    The clinical spectrum of internal carotid artery occlusion ranges from being a completely asymptomatic occlusion to a devastating stroke or death. The prevalence of asymptomatic internal carotid artery occlusion is unknown, particularly for bilateral occlusion. The distal branches of the external carotid artery anastomose with distal branches of the internal carotid artery provide important sources of collateral circulation to the brain. Stenosis of the external carotid artery with ipsilateral/bilateral internal occlusion may result in ischemic sequelae. Coiling or kinking of the vertebral artery is a rare morphological entity that is infrequently reported because it remains asymptomatic and has no clinical relevance. Currently, there is little evidence to support management strategies for this disease entity and no official recommendations for asymptomatic bilateral carotid artery occlusion. We present a case of a 62-year-old female with asymptomatic bilateral internal carotid artery occlusion, bilateral external carotid artery stenoses, and bilateral kinking of the vertebral artery at the V2 segment, who has been successfully managed conservatively for over 5 years. An individualized approach to management of patients with bilateral internal carotid artery occlusion, especially in combination with external carotid artery stenosis and elongation malformations of the vertebral artery is key to a successful strategy. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Final report on APMP.M.P-S4: Results of the bilateral supplementary comparison on pressure measurements in the range (60 to 350) kPa of gauge pressure in gas media

    NASA Astrophysics Data System (ADS)

    Priruenrom, T.; Sabuga, W.; Konczak, T.

    2013-01-01

    The bilateral supplementary comparison APMP.M.P-S4 on pressure measurements in the range (60 to 350) kPa of gauge pressure in gas media was organized by National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison is to check equivalence of gas pressure standards between NIMT and PTB. The period of measurement covered November to December 2012. NIMT provided a transfer standard, which was a WC-WC piston-cylinder assembly (PCA) with a nominal effective area of 10 cm2 manufactured by Fluke Corporation, DHI. The measurements were performed at pressures (60, 100, 150, 200, 250, 300 and 350) kPa. The NIMT laboratory standard used was a pressure balance with a PCA of 10 cm2 manufactured by DHI and identified by serial number 0693. The PTB laboratory standard used was a pressure balance with a PCA of 10 cm2 manufactured by Desgranges et Huot (DH) and identified by serial number 288. The results of this comparison show that the relative difference of the effective area values obtained by NIMT and PTB is not larger than 4.3 ppm, which corresponds to En = 0.26. Therefore, it confirms that the gas pressure standards maintained by the two institutes, NIMT and PTB, in the pressure range (60 to 350) kPa in gauge mode are equivalent under their uncertainties claimed. The result of this comparison is essential to support the calibration and measurement capabilities (CMC) of NIMT in this pressure range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Bilateral giant juvenile fibroadenomas of the breasts—a rare indication for bilateral skin reducing mastectomy

    PubMed Central

    Neto, Francisco Laitano; Zerwes, Felipe Pereira

    2016-01-01

    Fibroadenoma is the most common benign tumor of the breast but giant juvenile fibroadenoma represent only 0.5% of all fibroadenomas and when bilateral are much more rare. We describe the case of a 25 years old girl that presented with bilateral giant juvenile fibroadenomas and was treated by bilateral skin reducing mastectomy using the inferior dermal flap, implant, and free nipple graft. PMID:27563567

  2. APMP key comparison for the measurement of air kerma for 60Co (APMP.RI(I)-K1.1)

    NASA Astrophysics Data System (ADS)

    Webb, D. V.; Lee, J.-H.; Budiantari, C. T.; Laban, J.; Saito, N.; Srimanoroth, S.; Khaled, N. E.

    2016-01-01

    The results are reported for an APMP.R(I)-K1.1 comparison that extends the regional comparison of standards for air kerma APMP.R(I)-K1 to several laboratories unable to participate earlier. The comparison was conducted with the goal of supporting the relevant calibration and measurement capabilities (CMCs) planned for publication by the participant laboratories. The comparison was conducted by the pilot laboratory, the Australian Radiation Protection and Nuclear Safety (ARPANSA), Australia, supported by the Institute of Nuclear Energy Research (INER), Taiwan, in a modified ring-shaped arrangement from September 2009 to November 2010, in parallel with an APMP.R(I)-K4 comparison being piloted by the INER. The laboratories that took part in the comparison were the ARPANSA, the Centre of Technology of Radiation Safety and Metrology (PTKMR-BATAN), Indonesia, the Division of Radiation and Medical Devices (DMSC), Thailand, the INER, the National Centre for Radiation Science (NCRS), New Zealand, the National Institute for Standards (NIS), Egypt and the National Metrology Institute of Japan (NMIJ/AIST), Japan. The two primary laboratories, ARPANSA and NMIJ, were chosen as the linking laboratories. Three ionization chambers were used as transfer instruments to be calibrated in terms of air kerma in 60Co radiotherapy beams. The comparison result is based on the ratio between the air kerma calibration coefficients (NK) determined by the participants and the mean of the results of the linking laboratories. The mean comparison ratio was found to be within 0.5 % of the key comparison reference value KCRV. The largest deviation between any two comparison ratios for the three chambers in terms of air kerma was 2.0 %. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE) in terms of the deviations of the results and their associated uncertainties. As a result of this APMP comparison, the BIPM key comparison database (KCDB) should

  3. Use of tomotherapy in treatment of synchronous bilateral breast cancer: dosimetric comparison study

    PubMed Central

    Wadasadawala, T; Sarin, R; Upreti, R R; Paul, S; Phurailatpam, R

    2015-01-01

    Objective: Synchronous malignancy in both breasts is a rare incidence. The present study aims at dosimetric comparison of conventional bitangential radiotherapy (RT) technique with conventional [field-in-field (FIF)] and rotational [Helical TomoTherapy® and TomoDirect™ (TD); Accuray Inc., Sunnyvale, CA] intensity-modulated RT for patients with synchronous bilateral breast cancer (SBBC). Methods: CT data sets of 10 patients with SBBC were selected for the present study. RT was planned for all patients on both sides to whole breast and/or chest wall using the above-mentioned techniques. Six females with breast conservation on at least one side also had a composite plan along with tumour bed (TB) boost using sequential electrons for bitangential and FIF techniques or sequential helical tomotherapy (HT) boost (for TD) or simultaneous integrated boost (SIB) for HT. Results: All techniques produced acceptable target coverage. The hotspot was significantly lower with FIF technique and HT but higher with TD. For the organs at risk doses, HT resulted in significant reduction of the higher dose volumes. Similarly, TD resulted in significant reduction of the mean dose to the heart and total lung by reducing the lower dose volumes. All techniques of delivering boost to the TB were comparable in terms of target coverage. HT-SIB markedly reduced mean doses to the total lung and heart by specifically lowering the higher dose volumes. Conclusion: This study demonstrates the cardiac and pulmonary sparing ability of tomotherapy in the setting of SBBC. Advances in knowledge: This is the first study demonstrating feasibility of treatment of SBBC using tomotherapy. PMID:25605345

  4. Comparison of characteristics observed in tinnitus patients with unilateral vs bilateral symptoms, with both normal hearing threshold and distortion-product otoacoustic emissions.

    PubMed

    Zagólski, Olaf; Stręk, Paweł

    2017-02-01

    Tinnitus characteristics in normal-hearing patients differ between the groups with unilateral and bilateral complaints. The study was to determine the differences between tinnitus characteristics observed in patients with unilateral vs bilateral symptoms and normal hearing threshold, as well as normal results of distortion-product otoacoustic emissions (DPOAEs). The patients answered questions concerning tinnitus duration, laterality, character, accompanying symptoms, and circumstances of onset. The results of tympanometry, auditory brainstem responses, tinnitus likeness spectrum, minimum masking level (MML), and uncomfortable loudness level were evaluated. Records of 380 tinnitus sufferers were examined. Patients with abnormal audiograms and/or DPOAEs were excluded. The remaining 66 participants were divided into groups with unilateral and bilateral tinnitus. Unilateral tinnitus in normal-hearing patients was diagnosed twice more frequently than bilateral. Tinnitus pitch was higher in the group with bilateral tinnitus (p < .001). MML was lower in unilateral tinnitus (p < .05). Mean age of patients was higher in the unilateral tinnitus group (p < .05). Mean tinnitus duration was longer (p < .05) and hypersensitivity to sound was more frequent (p < .05) in the bilateral tinnitus group. Repeated exposure to excessive noise was the most frequent cause in the bilateral tinnitus group.

  5. Final report on the key comparison of hydrocarbon liquid flow: CCM.FF-K2.2015

    NASA Astrophysics Data System (ADS)

    Shimada, T.; Bittner-Rohrhofer, K.; Medina López, V. J.; Arias, R.; Su, C.-M.; Chen, I.-C.; Ribere, F.; Rowan, L.; Dignan, S.

    2016-01-01

    Seven laboratories: BEV (Austria), CENAM (Mexico), CMS (Chinese-Taipei), LNE-TRAPIL (France), NEL (United Kingdom), NMIA (Australia), and the pilot lab NMIJ (Japan), participated in the key comparison CCM.FF-K2.2015 for hydrocarbon flow measurement. A screw type positive displacement flow meter was selected as a transfer standard. The calibration stability of the transfer standard was evaluated from repeated measurements by NMIJ and showed standard reproducibility of 0.0035 %. The transfer standard was also thoroughly tested for sensitivity to temperature, viscosity, pressure, and other effects. The uncertainty due to the transfer standard of 0.0080 % was less than the quoted uncertainties of the participants. The key comparison reference values (KCRVs) at Reynolds number of 70 000 and 300 000 were obtained as the weighted mean from the calibration results, and the KCRV at Reynolds number of 100 000 was obtained as the median by using the Monte Carlo method according to Cox's procedure B, since the consistency check at Reynolds number of 100 000 failed at the 95 % confidence level. All participant results selected to determine the KCRVs have En values which show consistency with the evaluated KCRVs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. KEY COMPARISON: Final report on CCQM-K57: Chemical composition of clay

    NASA Astrophysics Data System (ADS)

    Salas, Antonio; Ramírez, Estele

    2009-01-01

    After the successful completion of the pilot study, CCQM-P65 [1], the Inorganic Analysis Working Group of CCQM agreed to conduct key comparison CCQM-K57, Chemical composition of clay, in Paris, April 2006. The natural mass fraction levels of five elements—Si, Ca, Fe, Al and Mg—were measured and reported as oxides in clay. Six national metrology institutes participated in CCQM K57, and CENAM (Querétaro, Mexico) coordinated. The methods employed were isotope dilution mass spectrometry (IDMS), inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-optical emission spectrometry (ICP-OES) using the dehydration method and condensation method, gravimetric analysis, neutron activation analysis (NAA), prompt gamma activation analysis (PGAA) and x-ray fluorescence spectrometry (XRF) with the reconstitution method and external calibration. This final report presents the capability of the participant institutes, based on the KCRV, which was approved at the IAWG spring meeting in 2008, and the equivalence statements regarding the KCRV, approved at its autumn meeting. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty.

    PubMed

    Steimle, Jerrod A; Groover, Michael T; Webb, Brad A; Ceccarelli, Brian J

    2018-01-01

    Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation.

  8. Bilateral hydronephrosis

    MedlinePlus

    ... general problems with urination. Alternative Names Hydronephrosis - bilateral Images Female urinary tract Male urinary tract References Elder JS. Obstruction of the urinary tract. In: Kliegman RM, ...

  9. Amnesia Associated with Bilateral Hippocampal and Bilateral Basal Ganglia Lesions in Anoxia with Stimulant Use

    PubMed Central

    Haut, Marc W.; Hogg, Jeffery P.; Marshalek, Patrick J.; Suter, Blair C.; Miller, Liv E.

    2017-01-01

    We report a case of a 55-year-old man with ischemic lesions of the bilateral hippocampus and bilateral basal ganglia following a myocardial infarction during an episode of multiple drug use with subsequent anoxia requiring resuscitation. He presented for a neuropsychological evaluation with an anterograde amnesia for both explicit and procedural memory. There are two main points to this case, the unique aspects of the bilateral multifocal lesions and the functional, cognitive impact of these lesions. We hypothesize that his rare focal bilateral lesions of both the hippocampus and basal ganglia are a result of anoxia acting in synergy with his stimulant drug use (cocaine and/or 3,4-methylenedioxy-methamphetamine). Second, his unique lesions produced an explicit and implicit/procedural anterograde amnesia. PMID:28228745

  10. Amnesia Associated with Bilateral Hippocampal and Bilateral Basal Ganglia Lesions in Anoxia with Stimulant Use.

    PubMed

    Haut, Marc W; Hogg, Jeffery P; Marshalek, Patrick J; Suter, Blair C; Miller, Liv E

    2017-01-01

    We report a case of a 55-year-old man with ischemic lesions of the bilateral hippocampus and bilateral basal ganglia following a myocardial infarction during an episode of multiple drug use with subsequent anoxia requiring resuscitation. He presented for a neuropsychological evaluation with an anterograde amnesia for both explicit and procedural memory. There are two main points to this case, the unique aspects of the bilateral multifocal lesions and the functional, cognitive impact of these lesions. We hypothesize that his rare focal bilateral lesions of both the hippocampus and basal ganglia are a result of anoxia acting in synergy with his stimulant drug use (cocaine and/or 3,4-methylenedioxy-methamphetamine). Second, his unique lesions produced an explicit and implicit/procedural anterograde amnesia.

  11. Final report of CCAUV.V-K3: key comparison in the field of acceleration on the complex charge sensitivity

    NASA Astrophysics Data System (ADS)

    Qiao, Sun; Lifeng, Yang; Bartoli, Claire; Veldman, Ian; Ripper, Gustavo P.; Bruns, Thomas; Rask Licht, Torben; Kolasa, Joanna; Hof, Christian; Silva Pineda, Guillermo; Dickinson, Laurence; Ota, Akihiro; Cheung, Wan Sup; Yankovsky, Alexander; Shan, Cui

    2017-01-01

    This is the final report for CIPM key comparison CCAUV.V-K3 in the area of 'vibration' (quantity of acceleration). The aim of this comparison was to measure the voltage sensitivity of one accelerometer standard set with primary means at 27 frequencies from 0.1 Hz to 40 Hz. Fourteen Metrology Institutes from five RMOs have participated in the comparison with National Institute of Metrology, P.R. China as pilot lab and Laboratoire National de Métrologie et d'Essais and National Metrology Institute of South Africa as co-pilot labs. One quartz-flexure servo accelerometer of single-ended type and a signal conditioner was circulated among the participants. All but one of the participating laboratories provided their calibration results, which were mostly consistent within their declared expanded uncertainties for magnitude results. Only two participants failed to contribute to the KCRV values calculated for five frequencies. For phase shift, three participants could not contribute to the calculation of the KCRV values in a total of sixteen frequencies. This first low-frequency vibration key comparison revealed the current calibration capabilities of the fourteen participants of five RMOs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Motor Experience Reprograms Development of a Genetically-Altered Bilateral Corticospinal Motor Circuit

    PubMed Central

    Serradj, Najet

    2016-01-01

    Evidence suggests that motor experience plays a role in shaping development of the corticospinal system and voluntary motor control, which is a key motor function of the system. Here we used a mouse model with conditional forebrain deletion of the gene for EphA4 (Emx1-Cre:EphA4tm2Kldr), which regulates development of the laterality of corticospinal tract (CST). We combined study of Emx1-Cre:EphA4tm2Kldr with unilateral forelimb constraint during development to expand our understanding of experience-dependent CST development from both basic and translational perspectives. This mouse develops dense ipsilateral CST projections, a bilateral motor cortex motor representation, and bilateral motor phenotypes. Together these phenotypes can be used as readouts of corticospinal system organization and function and the changes brought about by experience. The Emx1-Cre:EphA4tm2Kldr mouse shares features with the common developmental disorder cerebral palsy: bilateral voluntary motor impairments and bilateral CST miswiring. Emx1-Cre:EphA4tm2Kldr mice with typical motor experiences during development display the bilateral phenotype of “mirror” reaching, because of a strongly bilateral motor cortex motor representation and a bilateral CST. By contrast, Emx1-Cre:EphA4tm2Kldr mice that experienced unilateral forelimb constraint from P1 to P30 and tested at maturity had a more contralateral motor cortex motor representation in each hemisphere; more lateralized CST projections; and substantially more lateralized/independent reaching movements. Changes in CST organization and function in this model can be explained by reduced synaptic competition of the CST from the side without developmental forelimb motor experiences. Using this model we show that unilateral constraint largely abrogated the effects of the genetic mutation on CST projections and thus demonstrates how robust and persistent experience-dependent development can be for the establishment of corticospinal system

  13. Final Report on the Key Comparison CCM.P-K4.2012 in Absolute Pressure from 1 Pa to 10 kPa

    PubMed Central

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. PMID:28216793

  14. A 12-year anthropometric evaluation of the nose in bilateral cleft lip-cleft palate patients following nasoalveolar molding and cutting bilateral cleft lip and nose reconstruction.

    PubMed

    Garfinkle, Judah S; King, Timothy W; Grayson, Barry H; Brecht, Lawrence E; Cutting, Court B

    2011-04-01

    Patients with bilateral cleft lip-cleft palate have nasal deformities including reduced nasal tip projection, widened ala base, and a deficient or absent columella. The authors compare the nasal morphology of patients treated with presurgical nasoalveolar molding followed by primary lip/nasal reconstruction with age-matched noncleft controls. A longitudinal, retrospective review of 77 nonsyndromic patients with bilateral cleft lip-cleft palate was performed. Nasal tip protrusion, alar base width, alar width, columella length, and columella width were measured at five time points spanning 12.5 years. A one-sample t test was used for statistical comparison to an age-matched noncleft population published by Farkas. All five measurements demonstrated parallel, proportional growth in the treatment group relative to the noncleft group. The nasal tip protrusion, alar base width, alar width, columella length, and columella width were not statistically different from those of the noncleft, age-matched control group at age 12.5 years. The nasal tip protrusion also showed no difference in length at 7 and 12.5 years. The alar width and alar base width were significantly wider at the first four time points. This is the first study to describe nasal morphology following nasoalveolar molding and primary surgical repair in patients with bilateral cleft lip-cleft palate through the age of 12.5 years. In this investigation, the authors have shown that patients with bilateral cleft lip-cleft palate treated at their institution with nasoalveolar molding and primary nasal reconstruction, performed at the time of their lip repair, attained nearly normal nasal morphology through 12.5 years of age.

  15. Bilateral weighted radiographs are required for accurate classification of acromioclavicular separation: an observational study of 59 cases.

    PubMed

    Ibrahim, E F; Forrest, N P; Forester, A

    2015-10-01

    Misinterpretation of the Rockwood classification system for acromioclavicular joint (ACJ) separations has resulted in a trend towards using unilateral radiographs for grading. Further, the use of weighted views to 'unmask' a grade III injury has fallen out of favour. Recent evidence suggests that many radiographic grade III injuries represent only a partial injury to the stabilising ligaments. This study aimed to determine (1) whether accurate classification is possible on unilateral radiographs and (2) the efficacy of weighted bilateral radiographs in unmasking higher-grade injuries. Complete bilateral non-weighted and weighted sets of radiographs for patients presenting with an acromioclavicular separation over a 10-year period were analysed retrospectively, and they were graded I-VI according to Rockwood's criteria. Comparison was made between grading based on (1) a single antero-posterior (AP) view of the injured side, (2) bilateral non-weighted views and (3) bilateral weighted views. Radiographic measurements for cases that changed grade after weighted views were statistically compared to see if this could have been predicted beforehand. Fifty-nine sets of radiographs on 59 patients (48 male, mean age of 33 years) were included. Compared with unilateral radiographs, non-weighted bilateral comparison films resulted in a grade change for 44 patients (74.5%). Twenty-eight of 56 patients initially graded as I, II or III were upgraded to grade V and two of three initial grade V patients were downgraded to grade III. The addition of a weighted view further upgraded 10 patients to grade V. No grade II injury was changed to grade III and no injury of any severity was downgraded by a weighted view. Grade III injuries upgraded on weighted views had a significantly greater baseline median percentage coracoclavicular distance increase than those that were not upgraded (80.7% vs. 55.4%, p=0.015). However, no cut-off point for this value could be identified to predict an

  16. Total bilateral salpingectomy versus partial bilateral salpingectomy for permanent sterilization during cesarean delivery.

    PubMed

    Shinar, Shiri; Blecher, Yair; Alpern, Sharon; Many, Ariel; Ashwal, Eran; Amikam, Uri; Cohen, Aviad

    2017-05-01

    Sterilization via bilateral total salpingectomy is slowly replacing partial salpingectomy, as it is believed to decrease the incidence of ovarian cancer. Our objective was to compare short-term intra and post-operative complication rates of bilateral total salpingectomy versus partial salpingectomy performed during the course of a cesarean delivery. A large series of tubal sterilizations during cesarean sections were studied in a single tertiary medical center between 1/2014 and 8/2016 before and after a policy change was made, switching from partial salpingectomy to total salpingectomy. Patients who underwent bilateral partial salpingectomy using the modified Pomeroy technique were compared with those who underwent total salpingectomy. Operative length, estimated blood loss, postpartum fever, wound infection, need for re-laparotomy, hospitalization length, and blood transfusions were compared. During the study period, 149 women met inclusion criteria. Fifty parturients underwent bilateral total salpingectomy and 99 underwent partial salpingectomy in the course of the cesarean section. Demographic, obstetrical, and surgical characteristics were similar in both groups. Mean cesarean section duration was comparable for partial salpingectomy and total salpingectomy (a median of 35 min in both groups, P = 0.92). Complications were rare in both groups with no significant differences in rates of postpartum fever, wound infection, re-laparotomy, hospitalization length, estimated blood loss, transfusions, and readmissions within 1-month postpartum. Rates of short-term complications are similar in patients undergoing bilateral partial salpingectomy and total salpingectomy during cesarean deliveries, making the latter a feasible alternative to the former.

  17. Extruded upper first molar intrusion: Comparison between unilateral and bilateral miniscrew anchorage.

    PubMed

    Sugii, Mari Miura; Barreto, Bruno de Castro Ferreira; Francisco Vieira-Júnior, Waldemir; Simone, Katia Regina Izola; Bacchi, Ataís; Caldas, Ricardo Armini

    2018-01-01

    The aim of his study was to evaluate the stress on tooth and alveolar bone caused by orthodontic intrusion forces in a supraerupted upper molar, by using a three-dimensional Finite Element Method (FEM). A superior maxillary segment was modeled in the software SolidWorks 2010 (SolidWorks Corporation, Waltham, MA, USA) containing: cortical and cancellous bone, supraerupted first molar, periodontal tissue and orthodontic components. A finite element model has simulated intrusion forces of 4N onto a tooth, directed to different mini-screw locations. Three different intrusion mechanics vectors were simulated: anchoring on a buccal mini-implant; anchoring on a palatal mini-implant and the association of both anchorage systems. All analyses were performed considering the minimum principal stress and total deformation. Qualitative analyses exhibited stress distribution by color maps. Quantitative analysis was performed with a specific software for reading and solving numerical equations (ANSYS Workbench 14, Ansys, Canonsburg, Pennsylvania, USA). Intrusion forces applied from both sides (buccal and palatal) resulted in a more homogeneous stress distribution; no high peak of stress was detected and it has allowed a vertical resultant movement. Buccal or palatal single-sided forces resulted in concentrated stress zones with higher values and tooth tipping to respective force side. Unilateral forces promoted higher stress in root apex and higher dental tipping. The bilateral forces promoted better distribution without evidence of dental tipping. Bilateral intrusion technique suggested lower probability of root apex resorption.

  18. The role of P2X3 receptors in bilateral masseter muscle allodynia in rats

    PubMed Central

    Tariba Knežević, Petra; Vukman, Robert; Antonić, Robert; Kovač, Zoran; Uhač, Ivone; Simonić-Kocijan, Sunčana

    2016-01-01

    Aim To determine the relationship between bilateral allodynia induced by masseter muscle inflammation and P2X3 receptor expression changes in trigeminal ganglia (TRG) and the influence of intramasseteric P2X3 antagonist administration on bilateral masseter allodynia. Methods To induce bilateral allodynia, rats received a unilateral injection of complete Freund’s adjuvant (CFA) into the masseter muscle. Bilateral head withdrawal threshold (HWT) was measured 4 days later. Behavioral measurements were followed by bilateral masseter muscle and TRG dissection. Masseter tissue was evaluated histopathologically and TRG tissue was analyzed for P2X3 receptor mRNA expression by using quantitative real-time polymerase chain reaction (PCR) analysis. To assess the P2X3 receptor involvement in nocifensive behavior, two doses (6 and 60 μg/50 μL) of selective P2X3 antagonist A-317491 were administrated into the inflamed masseter muscle 4 days after the CFA injection. Bilateral HWT was measured at 15-, 30-, 60-, and 120-minute time points after A-317491 administration. Results HWT was bilaterally reduced after the CFA injection (P < 0.001). Intramasseteric inflammation was confirmed ipsilaterally to the CFA injection. Quantitative real-time PCR analysis demonstrated enhanced P2X3 expression in TRG ipsilaterally to CFA administration (P < 0.01). In comparison with controls, the dose of 6 μg of A-317491 significantly increased bilateral HWT at 15-, 30-, and 60-minute time points after the A-317491 administration (P < 0.001), whereas the dose of 60 μg of A-317491 was efficient at all time points ipsilaterally (P = 0.004) and at 15-, 30-, and 60-minute time points contralaterally (P < 0.001). Conclusion Unilateral masseter inflammation can induce bilateral allodynia in rats. The study provided evidence that P2X3 receptors can functionally influence masseter muscle allodynia and suggested that P2X3 receptors expressed in TRG neurons are involved in masseter

  19. Bilateral tension pneumothorax related to acupuncture.

    PubMed

    Tagami, Rumi; Moriya, Takashi; Kinoshita, Kosaku; Tanjoh, Katsuhisa

    2013-06-01

    We report on a patient with a rare case of bilateral tension pneumothorax that occurred after acupuncture. A 69-year-old large-bodied man, who otherwise had no risk factors for spontaneous pneumothorax, presented with chest pressure, cold sweats and shortness of breath. Immediately after bilateral pneumothorax had been identified on a chest radiograph in the emergency room, his blood pressure and percutaneous oxygen saturation suddenly decreased to 78 mm Hg and 86%, respectively. We confirmed deterioration in his cardiopulmonary status and diagnosed bilateral tension pneumothorax. We punctured his chest bilaterally and inserted chest tubes for drainage. His vital signs promptly recovered. After the bilateral puncture and drainage, we learnt that he had been treated with acupuncture on his upper back. We finally diagnosed a bilateral tension pneumothorax based on the symptoms that appeared 8 h after the acupuncture. Because the patient had no risk factors for spontaneous pneumothorax, no alternative diagnosis was proposed. We recommend that patients receiving acupuncture around the chest wall must be adequately informed of the possibility of complications and expected symptoms, as a definitive diagnosis can be difficult without complete information.

  20. [Bilateral caudate head infarcts].

    PubMed

    Kuriyama, N; Yamamoto, Y; Akiguchi, I; Oiwa, K; Nakajima, K

    1997-11-01

    We reported a 67-year-old woman with bilateral caudate head infarcts. She developed sudden mutism followed by abulia. She was admitted to our hospital 2 months after ictus for further examination. She showed prominent abulia and was inactive, slow and apathetic. Spontaneous activity and speech, immediate response to queries, spontaneous word recall and attention and persistence to complex programs were disturbed. Apparent motor disturbance, gait disturbance, motor aphasia, apraxia and remote memory disturbance were not identified. She seemed to be depressed but not sad. Brain CT and MRI revealed bilateral caudate head hemorrhagic infarcts including bilateral anterior internal capsules, in which the left lesion was more extensive than right one and involved the part of the left putamen. These infarct locations were thought to be supplied by the area around the medial striate artery including Heubner's arteries and the A1 perforator. Digital subtraction angiography showed asymptomatic right internal carotid artery occlusion. She bad had hypertension, diabetes mellitus and atrial fibrillation and also had a left atrium with a large diameter. The infarcts were thought to be caused by cardioembolic occlusion to the distal portion of the left internal carotid artery. Although some variations of vasculature at the anterior communicating artery might contribute to bilateral medial striate artery infarcts, we could not demonstrate such abnormalities by angiography. Bilateral caudate head infarcts involving the anterior internal capsule may cause prominent abulia. The patient did not improve by drug and rehabilitation therapy and died suddenly a year after discharge.

  1. Bilateral, independent juvenile nasopharyngeal angiofibroma: case report.

    PubMed

    Mørkenborg, M-L; Frendø, M; Stavngaard, T; Von Buchwald, C

    2015-10-01

    Juvenile nasopharyngeal angiofibroma is a benign, vascular tumour that primarily occurs in adolescent males. Despite its benign nature, aggressive growth patterns can cause potential life-threatening complications. Juvenile nasopharyngeal angiofibroma is normally unilateral, originating from the sphenopalatine artery, but bilateral symptoms can occur if a large tumour extends to the contralateral side of the nasopharynx. This paper presents the first reported case of true bilateral extensive juvenile nasopharyngeal angiofibroma involving clinically challenging pre-surgical planning and surgical strategy. A 21-year-old male presented with increasing bilateral nasal obstruction and discharge. Examination revealed tumours bilaterally and imaging demonstrated non-contiguous tumours. Pre-operative angiography showed strictly ipsilateral vascular supplies requiring bilateral embolisation. Radical removal performed as one-step, computer-assisted functional endoscopic sinus surgery was performed. The follow-up period was uncomplicated. This case illustrates the importance of suspecting bilateral juvenile nasopharyngeal angiofibroma in patients presenting with bilateral symptoms. Our management, including successful pre-operative planning, enabled one-step total removal of both tumours and rapid patient recovery.

  2. Final report on CCT-K6: Comparison of local realisations of dew-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.

    2015-01-01

    A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Bilateral neuroretinitis associated with mumps.

    PubMed

    Khubchandani, Raju; Rane, Tej; Agarwal, Premlata; Nabi, Fazal; Patel, Phiroze; Shetty, Avinash K

    2002-10-01

    Involvement of the optic nerve is a rare complication of mumps infection. To report a case of bilateral neuroretinitis complicating a mumps infection and to review 5 previously reported cases. Case report and literature review. Tertiary hospital. A 7-year-old girl had sudden-onset blindness due to bilateral neuroretinitis. Approximately 3 weeks prior to the initial examination, she developed a self-limited febrile illness with parotid swelling and subsequent meningoencephalitis. Mumps was determined to be the underlying cause of the meningoencephalitis and bilateral optic neuritis because of the exposure history in this nonvaccinated child, the typical clinical signs and symptoms, and the positive serologic test results. Recovery of visual function was gradual but nearly complete. Physicians should be aware that optic nerve involvement may be a manifestation of mumps infection. The delayed onset of optic neuritis, the bilateral involvement, and the near complete recovery suggest an immune-mediated pathogenesis.

  4. Bilateral medial medullary infarction due to bilateral vertebral artery dissection.

    PubMed

    Fukuda, Masafumi; Aiba, Toyotaka; Takahashi, Sho

    2004-03-01

    We describe a 52-year-old woman who experienced transient motor weakness and numbness of the left extremities and presented 2 days later with severe hemiparesis and sensory impairment of the right extremities and right lingual palsy. Magnetic resonance imaging (MRI) revealed bilateral upper medial medullary infarction, primarily in the left ventral portion. The findings of both three-dimensional (3D) computed tomographic and conventional angiography suggested dissection of both intracranial vertebral arteries (VAs). Medial medullary infarction is generally caused by atherosclerosis within a VA or anterior spinal artery. This is the first report of bilateral medial medullary infarction due to dissection of both intracranial VAs.

  5. KEY COMPARISON Comparison of the standards of air kerma of the ENEA-INMRI and the BIPM for 137Cs gamma rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Toni, M.; Bovi, M.

    2010-01-01

    A comparison of the standards of air kerma of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI) and of the Bureau International des Poids et Mesures (BIPM) was carried out in 137Cs radiation in 1998. The comparison result, updated for changes in the standards in 2003 and 2009, is 0.9927 (0.0067) and demonstrates that the ENEA-INMRI and BIPM standards are in agreement within the uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Medical tourism: a review of the literature and analysis of a role for bi-lateral trade.

    PubMed

    Smith, Richard; Martínez Álvarez, Melisa; Chanda, Rupa

    2011-12-01

    With increasing globalization, many countries are considering opening their health systems to greater cross-border movement of patients. This is usually done from the viewpoint of a multi-lateral trade relationship. This paper considers the issues that arise from this debate from a bi-lateral perspective. A systematic literature review was carried out on 'Medical Tourism' from the perspective of a bi-lateral trade relationship, using the UK and India as a case study. There is a dearth of data and discussion on such bi-lateral trade. This limited evidence offers some suggestions. Exporting countries may benefit from medical tourism by generating foreign exchange and reversing the brain drain, but run the risk of creating a dual system, where the local population is crowded out. Importing countries can benefit from alleviating waiting lists and lowering healthcare costs, but may risk quality of care and legal liability. However, evidence from a bi-lateral perspective suggests that the positive aspects can be capitalised, and the negative ones reduced. The key recommendations from this paper are for more evidence to be collected at the country and international level, and for countries to consider trade in health services from a bi-lateral rather than multi-lateral perspective. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Effects of Bilateral Repetitive Transcranial Magnetic Stimulation on Post-Stroke Dysphagia.

    PubMed

    Park, Eunhee; Kim, Min Su; Chang, Won Hyuk; Oh, Su Mi; Kim, Yun Kwan; Lee, Ahee; Kim, Yun-Hee

    Optimal protocol of repetitive transcranial magnetic stimulation (rTMS) on post-stroke dysphagia remains uncertain with regard to its clinical efficacy. The aim of the present study is to investigate the effects of high-frequency rTMS at the bilateral motor cortices over the cortical representation of the mylohyoid muscles in the patients with post-stroke dysphagia. This study was a single-blind, randomized controlled study with a blinded observer. Thirty-five stroke patients were randomly divided into three intervention groups: the bilateral stimulation group, the unilateral stimulation group, and the sham stimulation group. For the bilateral stimulation group, 500 pulses of 10 Hz rTMS over the ipsilesional and 500 pulses of 10 Hz rTMS over the contralesional motor cortices over the cortical areas that project to the mylohyoid muscles were administered daily for 2 consecutive weeks. For the unilateral stimulation group, 500 pulses of 10 Hz rTMS over the ipsilesional motor cortex over the cortical representation of the mylohyoid muscle and the same amount of sham rTMS over the contralesional hemisphere were applied. For the sham stimulation group, sham rTMS was applied at the bilateral motor cortices. Clinical swallowing function and videofluoroscopic swallowing studies were assessed before the intervention (T0), immediately after the intervention (T1) and 3 weeks after the intervention (T2) using Clinical Dysphagia Scale (CDS), Dysphagia Outcome and Severity Scale (DOSS), Penetration Aspiration Scale (PAS), and Videofluoroscopic Dysphagia Scale (VDS). There were significant time and intervention interaction effects in the CDS, DOSS, PAS, and VDS scores (p < 0.05). In the direct comparison of the changes in the swallowing parameters among the three groups, the change in CDS scores at T1 and T2 showed a significantly higher improvement in the bilateral simulation group than in two other groups (p < 0.05). There was a significantly larger change in the

  8. A comparison of bilateral versus unilateral target and distractor presentation in the remote distractor paradigm.

    PubMed

    Benson, Valerie

    2008-01-01

    The remote distractor effect (RDE) is a robust finding of an increase in saccade onset latencies (20-40 ms) when a distractor is presented simultaneously with a target, compared to when a target is presented on its own (Walker, Deubel, Schneider, & Findlay, 1997). Distractors presented at fixation produce the largest RDE and the effect decreases as distractors are moved into the periphery. Data from two experiments that contrast with these standard findings are reported. Under bilateral target presentation, larger RDE magnitudes occurred for peripheral than for central distractors, whereas under unilateral presentation, the pattern reversed. The findings are discussed with reference to discrimination processes, attentional factors and current models of oculomotor control. It is suggested that in bilateral target presentation the competition between the distractor and the target results in the programming of a saccade to the distractor, as well as a saccade to the target. Time taken to cancel the saccade to the distractor produces the increased saccade latency for peripheral distractors in that condition.

  9. Bilateral juvenile nasopharyngeal angiofibroma: report of a case.

    PubMed

    Wu, Edward C; Chark, Davin W; Bhandarkar, Naveen D

    2014-07-01

    Juvenile nasopharyngeal angiofibroma (JNA) is the most common benign neoplasm of the nasopharynx. Almost always unilateral on diagnosis, JNAs are locally invasive and may extend across the midline, giving a false bilateral appearance; as such, true bilateral JNA is exceedingly rare. We present a recent case of true bilateral JNA. Single case report of a patient with bilateral JNA, including clinical presentation, diagnosis, and management. The patient presented with unilateral nasal obstruction and recurrent epistaxis. Computed tomography and magnetic resonance imaging demonstrated bilateral, noncontiguous masses. Angiography revealed independent vascular supplies from each respective side with no bilateral supply noted. The patient underwent preoperative embolization followed by endoscopic surgical removal of the larger mass; no complications were noted. Follow-up at 2 years demonstrated no recurrence or growth. The vast majority of JNAs are unilateral, though invasive growth to the contralateral side may appear "bilateral" in presentation. Proper identification of true bilateral JNA is helpful in guiding management, wherein excision of both tumors may not be necessary. © 2014 ARS-AAOA, LLC.

  10. Key comparison SIM.EM.RF-K5b.CL: scattering coefficients by broad-band methods, 2 GHz-18 GHz — type N connector

    NASA Astrophysics Data System (ADS)

    Silva, H.; Monasterios, G.

    2016-01-01

    The first key comparison in microwave frequencies within the SIM (Sistema Interamericano de Metrología) region has been carried out. The measurands were the S-parameters of 50 ohm coaxial devices with Type-N connectors and were measured at 2 GHz, 9 GHz and 18 GHz. SIM.EM.RF-K5b.CL was the identification assigned and it was based on a parent CCEM key comparison named CCEM.RF-K5b.CL. For this reason, the measurements standards and their nominal values were selected accordingly, i.e. two one-port devices (a matched and a mismatched load) to cover low and high reflection coefficients and two attenuators (3dB and 20 dB) to cover low and high transmission coefficients. This key comparison has met the need for ensuring traceability in high-frequency measurements across America by linking SIM's results to CCEM. Six NMIs have participated in this comparison which was piloted by the Instituto Nacional de Tecnología Industrial (Argentina). A linking method of multivariate values was proposed and implemented in order to allow the linking of 2-dimensional results. KEY WORDS FOR SEARCH Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. SUPPLEMENTARY COMPARISON COOMET. M.P-S5 of hydraulic gauge pressure standards from 5 MPa to 34 MPa

    NASA Astrophysics Data System (ADS)

    Babayev, E. A.; Klenovská, Simona; Páviš, Richard; Pražák, Dominik

    2018-01-01

    This report describes the results of bilateral inter laboratory comparison (BILC) denoted as COOMET.M.P-S5 (also known as supplementary comparison COOMET 723/AZ/17). The comparison measurements between the two participants, Czech Metrology Institute (CMI) (pilot laboratory) and Azerbaijan İnstitute of Metrology (AzMI), started in April 2017 and finished in June 2017. The transfer standards was a digital manometer, Crystal XP 2i with the gauge pressure range (0–34000) kPa. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral solar retinopathy. Autofluorescence and optical coherence tomography.

    PubMed

    Rocha Cabrera, P; Cordovés Dorta, L; González Hernández, M

    2016-08-01

    A 33-year-old man referred decreased bilateral visual acuity for five years, with no history of interest. Military profession and probably previous sun exposure. Focal pigmented lesions in the macular area of the fundus were observed, with impairment of the photoreceptor layer in the fovea, observed by optical coherence tomography (OCT), in various sectors of the fovea. Solar retinopathy is associated with professions at risk of sun exposure. The diagnosis is based on autofluorescence and macular OCT, that later will provide key data to establish the cause. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  13. KEY COMPARISON: Results of the APMP Pressure key comparison APMP.M.P-K1c in gas media and gauge mode from 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, A. K.; Woo, Sam Yong; Fitzgerald, Mark; Man, John; Ooiwa, Akira; Jescheck, M.; Jian, Wu; Fatt, Chen Soo; Chan, T. K.; Moore, Ken; El-Tawil, Alaaeldin A. E.

    2003-01-01

    This report summarizes the results of a regional key comparison (APMP-IC-2-97) under the aegis of the Asia Pacific Metrology Program (APMP) for pressure measurements in gas media and in gauge mode from 0.4 MPa to 4.0 MPa. The transfer standard was a pressure-balance with a piston-cylinder assembly with nominal effective area 8.4 mm2 (V-407) and was supplied by the National Metrology Institute of Japan [NMIJ]. Ten standard laboratories from the APMP region with one specially invited laboratory from the EUROMET region, namely Physikalisch-Technische Bundesanstalt (PTB), Germany, participated in this comparison. The comparison started in October 1998 and was completed in May 2001. The pilot laboratory prepared the calibration procedure [1] as per the guidelines of APMP and the International Bureau of Weights and Measures (BIPM) [2-4]. Detailed instructions for performing this key comparison were provided in the calibration protocol [1] and the required data were described in: (1) Annex 3 - characteristics of the laboratory standards, (2) Annex 4 - the effective area (A'p'/mm2) (the prime indicates values based on measured quantities) at 23°C of the travelling standard as a function of nominal pressure (p'/MPa) (five cycles both increasing and decreasing pressures at ten pre-determined pressure points) and (3) Annex 5 - the average effective area at 23°C (A'p'/mm2) obtained for each pressure p'/MPa with all uncertainty statements. The pilot laboratory processed the information and the data provided by the participants for these three annexes, starting with the information about the standards as provided in Annex 3. Based on this information, the participating laboratories are classified into two categories: (I) laboratories that are maintaining primary standards, and (II) laboratories that are maintaining standards loosely classified as secondary standards with a clear traceability as per norm of the BIPM. It is observed that out of these eleven laboratories, six

  14. Foveal retinoschisis misdiagnosed as bilateral amblyopia.

    PubMed

    Kyung, Sungeun E; Lee, Minsoo

    2012-12-01

    Juvenile foveal retinoschisis is one of the most common causes of bilateral macular degeneration in young boys. School age with accommodative esotropia may develop amblyopia due to late correction of hyperopia. Retinoschisis is hard to diagnose in patient with subtle macula change and hyperopic amblyopia. We report a case of bilateral foveal retinoschisis before and after treatment with topical dorzolamide, which was misdiagnosed as bilateral hyperopic amblyopia. Optical coherence tomography should be considered in diagnostic procedures of children with hyperopic amblyopia.

  15. KEY COMPARISON: CCEM.RF-K9: International comparison of thermal noise standards between 12.4 GHz and 18 GHz (GT-RF/99-1)

    NASA Astrophysics Data System (ADS)

    Allal, Djamel; Achkar, Joseph

    2006-01-01

    An international comparison of thermal noise-power measurements has been carried out among five national metrology institutes between 12.4 GHz and 18 GHz. Four transfer standards were measured. The following national institutes participated: BNM-LCIE (France), NPL (United Kingdom), PTB (Germany), NIST (United States of America) and VNIIFTRI (Russia). The Bureau National de Métrologie-Laboratoire Central des Industries Electriques (France) acted as the pilot laboratory for the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays.

    PubMed

    Burns, D T; Kessler, C; O'Brien, M; Minniti, R

    2012-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x-ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 10 3 , except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database.

  17. Outcomes evaluation following bilateral breast reconstruction using latissimus dorsi myocutaneous flaps.

    PubMed

    Losken, Albert; Nicholas, Claire S; Pinell, Ximena A; Carlson, Grant W

    2010-07-01

    The demand for bilateral breast reconstruction has recently increased. Although numerous options exist, the latissimus dorsi myocutaneous flap remains a popular technique. The benefits of additional autologous coverage are evident; however, donor site morbidity does exist. The purpose of this report is to evaluate our experience with bilateral latissimus dorsi breast reconstructions, focusing on donor site morbidity and patient satisfaction. All patients who underwent bilateral latissimus dorsi breast reconstruction at Emory University Hospital, were evaluated and included in the series. Data points queried included patient demographics, risk factors, radiation therapy, timing of the procedure (immediate or delayed), type of procedure (latissimus dorsi only, latissimus dorsi with expander, latissimus dorsi with implant), and outcomes. Outcomes included >1 additional operation, any breast and any donor-site complications. A patient satisfaction survey was performed evaluating outcomes such as aesthetic results, general satisfaction, morbidities, and functional assessment. Comparisons were made using radiation therapy, timing of reconstruction, and type of reconstruction as variables. Eighty-three patients underwent bilateral latissimus dorsi breast reconstruction with an average follow-up of 2.3 years. The method of reconstruction included latissimus dorsi with expander (n = 54), latissimus dorsi only (n = 17), and latissimus dorsi with implant (n = 12). Breast complications occurred in 34% of the patients with radiation therapy being a significant risk factor. The average number of secondary operations was 2.3 with the expander group resulting in an increased need for additional procedures. Overall patient satisfaction was 3.93/5, with the average symmetry score being 3.82/5, shape 3.84/5, nipple position 3.92/5, and inframammary fold (IMF) position 4/5. The majority of patients (n = 28/37) reported no pain (0/5) at the time of the survey. Most patients (n = 33

  18. Bilateral Facial Paralysis: A 13-Year Experience.

    PubMed

    Gaudin, Robert A; Jowett, Nathan; Banks, Caroline A; Knox, Christopher J; Hadlock, Tessa A

    2016-10-01

    Bilateral facial palsy is a rare clinical entity caused by myriad disparate conditions requiring different treatment paradigms. Lyme disease, Guillain-Barré syndrome, and leukemia are several examples. In this article, the authors describe the cause, the initial diagnostic approach, and the management of long-term sequelae of bilateral paralysis that has evolved in the authors' center over the past 13 years. A chart review was performed to identify all patients diagnosed with bilateral paralysis at the authors' center between January of 2002 and January of 2015. Demographics, signs and symptoms, diagnosis, initial medical treatment, interventions for facial reanimation, and outcomes were reviewed. Of the 2471 patients seen at the authors' center, 68 patients (3 percent) with bilateral facial paralysis were identified. Ten patients (15 percent) presented with bilateral facial paralysis caused by Lyme disease, nine (13 percent) with Möbius syndrome, nine (13 percent) with neurofibromatosis type 2, five (7 percent) with bilateral facial palsy caused by brain tumor, four (6 percent) with Melkersson-Rosenthal syndrome, three (4 percent) with bilateral temporal bone fractures, two (3 percent) with Guillain-Barré syndrome, one (2 percent) with central nervous system lymphoma, one (2 percent) with human immunodeficiency virus infection, and 24 (35 percent) with presumed Bell palsy. Treatment included pharmacologic therapy, physical therapy, chemodenervation, and surgical interventions. Bilateral facial palsy is a rare medical condition, and treatment often requires a multidisciplinary approach. The authors outline diagnostic and therapeutic algorithms of a tertiary care center to provide clinicians with a systematic approach to managing these complicated patients.

  19. Key comparison BIPM.RI(I)-K9 of the absorbed dose to water standards of the PTB, Germany and the BIPM in medium-energy x-rays

    NASA Astrophysics Data System (ADS)

    Burns, D. T.; Kessler, C.; Büermann, L.; Ketelhut, S.

    2018-01-01

    A key comparison has been made between the absorbed dose to water standards of the PTB, Germany and the BIPM in the medium-energy x-ray range. The results show the standards to be in general agreement at the level of the standard uncertainty of the comparison of 9 to 11 parts in 103. The results are combined with those of a EURAMET comparison and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the SMU, Slovakia and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    A key comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0042 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Asymmetric pelvic and hip rotation in children with bilateral cerebral palsy: uni- or bilateral femoral derotation osteotomy?

    PubMed

    Niklasch, M; Döderlein, L; Klotz, M C; Braatz, F; Wolf, S I; Dreher, T

    2015-02-01

    Internal rotation gait is common among children with bilateral cerebral palsy. However, despite bilaterally increased femoral anteversion asymmetric internal rotation gait is often found. Femoral derotation osteotomy (FDO) is commonly performed bilaterally. Variable functional outcomes are reported especially in cases with mild internal hip rotation during gait and abnormal preoperative pelvic rotation. A major question is if a unilateral treatment of the more involved side in asymmetric cases leads to a comparable or even superior outcome. One hundred and nine children with spastic bilateral CP treated with FDO with pre- and 1-year postoperative 3D gait analysis were retrospectively collected. The asymmetry was calculated from the preoperative difference between both limbs in hip rotation obtained by 3D gait analysis. Twenty-eight children with asymmetry larger than 20° were selected and classified into two groups, according to whether they obtained a unilateral or bilateral FDO. Preoperative clinical examination and pre- and postoperative hip and pelvic rotation in gait analysis on the more and the less involved side did not differ significantly between both groups. Interestingly, in both groups, hip rotation did not change significantly in less-involved limbs, although intraoperative derotation averaged 25°. After unilateral FDO a significant change in pelvic rotation resulted, whereas this was not found after bilateral FDO. The results of this study suggest that unilateral FDO in children with asymmetric internal rotation gait leads to a comparable functional outcome compared to bilateral treatment. Furthermore, it was shown for the first time that considering the asymmetry has a positive effect on pelvic rotation. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Final report on SIM Regional Key Comparison SIM.L-K1.2007: Calibration of gauge blocks by optical interferometry

    NASA Astrophysics Data System (ADS)

    Colín, C.; Viliesid, M.; Chaudhary, K. P.; Decker, J.; Dvorácek, F.; Franca, R.; Ilieff, S.; Rodríguez, J.; Stoup, J.

    2012-01-01

    This Key Comparison of gauge blocks (GB) calibration by optical interferometry was carried out to support this Calibration and Measurement Capability (CMC) of the National Measurement Institutes (NMI) from the SIM Region for this specific service and for those that rely on this kind of technique as required by the Mutual Recognition Arrangement (MRA). It provides evidence of the participant's technical competence and supports the uncertainties they state in their CMC. It is a Regional Key Comparison and should be linked to the upper level corresponding comparison CCL-K1. The comparison had nine participants, five from the SIM Region—NRC-CNRC, Canada; NIST, USA; CENAM, Mexico; INMETRO, Brazil; and INTI, Argentina— and four from other regions—CMI, Czech Rep.; CEM, Spain; NPLI, India; and NMISA South Africa. It included the circulation of fourteen GB—seven steel GB and seven ceramic GB. The circulation of the artifacts started on 2007-11-01 and ended on 2010-04-25. Some additional time was required to publish the results as the same artifacts were used thereafter for comparison SIM.L-S6, Calibration of GB by mechanical comparison, and the results could not be disclosed until the participants of the second circulation loop had sent their results. The final report of this comparison was sent out for review in May 2012 and the final version was approved in August 2012. The behavior of the artifacts throughout the circulation was good and therefore the results obtained were judged technically valid. The reference value was taken as arithmetic mean of the largest subset of consistent results. Most of participates obtained results in good agreement with the reference values with a few exceptions mentioned in the report. The corresponding NMIs are responsible for identifying the causes and taking corrective action. This makes the present comparison exercise valid to support the CMC claims of the participants in GB calibration by optical interferometry. Main text. To

  3. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays

    PubMed Central

    Burns, D T; Kessler, C; O’Brien, M; Minniti, R

    2017-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x–ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 103, except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. PMID:28966399

  4. Final report on key comparison EURAMET.M.P-K13 in the range 50 MPa to 500 MPa of hydraulic gauge pressure

    NASA Astrophysics Data System (ADS)

    Kocas, I.; Sabuga, W.; Bergoglio, M.; Eltaweel, A.; Korasie, C.; Farar, P.; Setina, J.; Waller, B.; Durgut, Y.

    2015-01-01

    The regional key comparison EURAMET.M.P-K13 for pressure measurements in liquid media from 50 MPa to 500 MPa was piloted by the TÜBİTAK UME Pressure Group Laboratories, Turkey. The transfer standard was a DH-Budenberg pressure balance with a free deformation piston-cylinder unit of 2 mm2 nominal effective area. Six laboratories from the EURAMET region, namely PTB, INRIM, SMU, IMT, NPL and UME, and two laboratories from the AFRIMETS region, NIS and NMISA participated in this comparison. Participant laboratories and countries are given in the bottom of the page. PTB participated in this comparison to provide a link to corresponding 500 MPa CCM key comparison CCM.P-K13. The results of all participants excepting NMISA and NPL were found to be consistent with the reference value of the actual comparison and of CCM.P-K13 within their claimed uncertainties (k = 2), at all pressures. Compared in pairs all laboratories with exception of NPL and NMISA demonstrate their agreement with each other within the expanded uncertainties (k = 2) at all pressures. The results are therefore considered to be satisfactory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral mandibular angle fractures: clinical considerations.

    PubMed

    Boffano, Paolo; Roccia, Fabio

    2010-03-01

    The mandibular angle is a frequent site of fracture. It is a weak zone that is more exposed to fractures than other areas of the mandibular bone. The presence of incompletely erupted third molars is associated with a further increased risk of angle fractures. Our objective was to evaluate and discuss the surgical outcomes of a group of patients with bilateral mandibular angle fractures.In our study, patients with bilateral mandibular angle fractures surgically treated from January 1, 2001, to June 30, 2009, at the Division of Maxillofacial Surgery of the University of Turin were retrospectively analyzed. A combined transbuccal and intraoral approach or an intraoral approach only was adopted.Eight patients (7 men and 1 woman) underwent surgery for bilateral mandibular angle fractures. Good to satisfactory reduction of the fractures was obtained with both surgical techniques. Good to fair restored occlusion was observed postoperatively in all patients.Successful treatment of bilateral mandibular angle fractures may be achieved via different techniques. Superficially impacted third molars seem to be associated with an increased risk of angle fractures. Bilateral angle fractures are an ideal model to study the biomechanical pathogenesis of angle fractures.

  6. Bilateral renal calculi

    PubMed Central

    Sreenevasan, G

    1974-01-01

    Bilateral renal calculi were present in 114 (10.7%) of 1,070 cases of proved urinary calculus admitted to the Urological Department of the General Hospital, Kuala Lumpur, during the period November 1968—May 1973. The management of bilateral renal calculi is discussed with reference to the first 100 cases in this series. The introduction of renography has greatly facilitated the decision as to which kidney should be operated on first. The management of patients with and without uraemia is discussed and the use of the modified V and V—Y incisions for the removal of staghorn calculi is described. Complications and results are briefly reviewed. ImagesFig. 1Fig. 4Fig. 6Fig. 7 PMID:4845653

  7. Song Recognition by Young Children with Cochlear Implants: Comparison between Unilateral, Bilateral, and Bimodal Users

    ERIC Educational Resources Information Center

    Bartov, Tamar; Most, Tova

    2014-01-01

    Purpose: To examine song identification by preschoolers with normal hearing (NH) versus preschoolers with cochlear implants (CIs). Method: Participants included 45 children ages 3;8-7;3 (years;months): 12 with NH and 33 with CIs, including 10 with unilateral CI, 14 with bilateral CIs, and 9 bimodal users (CI-HA) with unilateral CI and…

  8. Report on key comparison COOMET.AUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Dobrowolska, D.; Kosterov, A.

    2016-01-01

    This is the final report for regional key comparison COOMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Two laboratories—Central Office of Measures (GUM)—the national metrology institute for Poland and the State Enterprise Scientific-Research Institute for Metrology of Measurement and Control Systems (DP NDI Systema)— the designated institute for acoustics in Ukraine took part in this comparison with the GUM as a pilot. One travelling type LS1P microphone was circulated to the participants and results in the form of regular calibration certificates were collected. The results of the DP NDI Systema obtained in this comparison were linked to the CCAUV.A-K5 key comparison through the joint participation of the GUM. The degrees of equivalence were computed for DP NDI Systema with respect to the CCAUV.A-K5 key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Postoperative Stiffness Requiring Manipulation Under Anesthesia Is Significantly Reduced After Simultaneous Versus Staged Bilateral Total Knee Arthroplasty.

    PubMed

    Meehan, John P; Monazzam, Shafagh; Miles, Troy; Danielsen, Beate; White, Richard H

    2017-12-20

    For patients with symptomatic bilateral knee arthritis, it is unknown whether the risk of developing stiffness requiring manipulation under anesthesia postoperatively is higher or lower for those undergoing simultaneous bilateral total knee arthroplasty (TKA) compared with those having staged bilateral TKA. Therefore, we undertook this study to evaluate the risk of requiring manipulation under anesthesia in staged versus simultaneous bilateral TKA as well as patients undergoing unilateral TKA. We utilized the California Patient Discharge Database, which is linked with the California Emergency Department, Ambulatory Surgery, and master death file databases. Using a literature-based estimate of the number of patients who failed to undergo the second stage of a staged bilateral TKA, replacement cases were randomly selected from patients who had unilateral TKA and were matched on 8 clinical characteristics of the patients who had staged bilateral TKA. Hierarchical multivariate logistic regression was performed to determine the risk-adjusted odds of manipulation in patients undergoing unilateral TKA, staged bilateral TKA, and simultaneous bilateral TKA using yearly hospital TKA volume as a random effect. Adjustment was made to allow fair comparison of the outcome at 90 and 180 days of follow-up after staged compared with simultaneous bilateral TKA. During the time period from 2005 through 2013, the cumulative incidence of manipulation within 90 days was 2.14% for unilateral TKA (4,398 events per 205,744 patients), 2.11% for staged bilateral TKA (724 events per 34,352 patients), and 1.62% for simultaneous bilateral TKA (195 events per 12,013 patients). At 180 days of complete follow-up, the cumulative incidence of manipulation was 3.07% after unilateral TKA (6,313 events per 205,649 patients), 2.89% after staged bilateral TKAs (957 events per 33,169 patients), and 2.29% after simultaneous bilateral TKA (267 events per 11,653 patients). With multivariate analyses used to

  10. Bilateral vocal cord paralysis in children.

    PubMed

    Chen, Eunice Y; Inglis, Andrew F

    2008-10-01

    Bilateral vocal cord paralysis in children with its many causes presents a challenging problem to the pediatric otolaryngologist. Traditionally, management of bilateral vocal cord paralysis includes securing the airway with a tracheotomy and waiting for spontaneous recovery. Surgeons have tried a variety of surgical procedures in lieu of or in addition to tracheotomy, but none are perfect solutions to the problem. This article reviews the current surgical procedures for bilateral vocal cord paralysis in the pediatric population with a particular focus on the senior author's experience with the endoscopic posterior costal cartilage grafting procedure.

  11. Outcome and cost analysis of bilateral sequential same-day cartilage tympanoplasty compared with bilateral staged tympanoplasty.

    PubMed

    Olusesi, A D; Oyeniran, O

    2017-05-01

    Few studies have compared bilateral same-day with staged tympanoplasty using cartilage graft materials. A prospective randomised observational study was performed of 38 chronic suppurative otitis media patients (76 ears) who were assigned to undergo bilateral sequential same-day tympanoplasty (18 patients, 36 ears) or bilateral sequential tympanoplasty performed 3 months apart (20 patients, 40 ears). Disease duration, intra-operative findings, combined duration of surgery, post-operative graft appearance at 6 weeks, post-operative complications, re-do rate and relative cost of surgery were recorded. Tympanic membrane perforations were predominantly subtotal (p = 0.36, odds ratio = 0.75). Most grafts were harvested from the conchal cartilage and fewer from the tragus (p = 0.59, odds ratio = 1.016). Types of complication, post-operative hearing gain and revision rates were similar in both patient groups. Surgical outcomes are not significantly different for same-day and bilateral cartilage tympanoplasty, but same-day surgery has the added benefit of a lower cost.

  12. Oral Bilateral Collagenous Fibroma: A previously unreported case and literature review.

    PubMed

    Vasconcelos, Ana-Carolina; Gomes, Ana-Paula; Tarquinio, Sandra; Abduch-Rodrigues, Eduardo; Mesquita, Ricardo; Silva, Karine

    2018-01-01

    Collagenous fibroma, also known as desmoplastic fibroblastoma, is a rare benign slow growing tumor particularly uncommon in the oral cavity. The aim of this study was to analyze the clinical and histopathological features of an oral collagenous fibroma as well as to compare this data with those reported in an English-literature review. The thirteenth case of collagenous fibroma in the oral cavity and the first to present clinically as a bilateral mass was described. A 48-years-old female patient was referred to a School of Dentistry, complaining about an asymptomatic swelling on the hard palate, lasting around ten years. The intraoral examination revealed two well-defined mass, bilaterally in the hard palate. An excisional biopsy was performed. Microscopically, the connective tissue consisted of dense collagen bundles in which were seen scarcely distributed spindle-shaped to stellate fibroblastic cells. Blood vessels were few, as well as inflammatory cells. Immunohistochemical staining was positive for vimentin, α-smooth muscle actin and factor XIIIa and negative for S-100, CD68, CD34, HHF35, desmin and AE1/AE3. The patient remains disease-free 24 months after excision. In conclusion, oral collagenous fibroma should be included in the differential diagnosis of bilateral sessile nodules in the oral cavity. Key words: Connective tissue, mouth diseases, mouth neoplasms, oral diagnosis, oral pathology.

  13. Improving neurovascular outcomes with bilateral forepaw stimulation in a rat photothrombotic ischemic stroke model

    PubMed Central

    Liao, Lun-De; Bandla, Aishwarya; Ling, Ji Min; Liu, Yu-Hang; Kuo, Li-Wei; Chen, You-Yin; King, Nicolas KK; Lai, Hsin-Yi; Lin, Yan-Ren; Thakor, Nitish V.

    2014-01-01

    Abstract. Restoring perfusion to the penumbra during the hyperacute phase of ischemic stroke is a key goal of neuroprotection. Thrombolysis is currently the only approved treatment for ischemic stroke. However, its use is limited by the narrow therapeutic window and side effect of bleeding. Therefore, other interventions are desired that could potentially increase the perfusion of the penumbra. Here, we hypothesized that bilateral peripheral electrical stimulation will improve cerebral perfusion and restore cortical neurovascular response. We assess the outcomes of bilateral forepaw electrical stimulation at intensities of 2 and 4 mA, administered either unilaterally or bilaterally. We developed a combined electrocorticogram (ECoG)-functional photoacoustic microscopy (fPAM) system to evaluate the relative changes in cerebral hemodynamic function and electrophysiologic response to acute, focal stroke. The fPAM system is used for cerebral blood volume (CBV) and hemoglobin oxygen saturation (SO2) and the ECoG for neural activity, namely somatosensory-evoked potential (SSEP), interhemispheric coherence, and alpha-delta ratio (ADR) in response to forepaw stimulation. Our results confirmed the neuroprotective effect of bilateral forepaw stimulation at 2 mA as indicated by the 82% recovery of ADR and 95% improvement in perfusion into the region of penumbra. This experimental model can be used to study other potential interventions such as therapeutic hypertension and hypercarbia. PMID:26157965

  14. Bilateral tension pneumothorax after acupuncture.

    PubMed

    Mohammad, Nurashikin

    2018-04-19

    Acupuncture is an ancient complementary medicine which is currently used worldwide. Many serious adverse events have been reported which include a spectrum of mild-to-fatal complications. However, the level of awareness with regard to complications is still low both to physicians and patients. We report a 63-year-old who presented with acute shortness of breath 2 hours after having had acupuncture. On examination, there was absent breath sound heard on the left lung and slightly reduced breath sound on the right lung. She had type 1 respiratory failure. Urgent chest radiograph confirmed bilateral pneumothorax which was more severe on the left with tension pneumothorax and mediastinal shift. Chest tubes were inserted bilaterally after failed needle aspiration attempts. Subsequently, the pneumothoraces resolved, and she was discharged well. The bilateral pneumothoraces caused by acupuncture were curable but could have been potentially fatal if diagnosis was delayed. This case report adds to the limited current literature on the complications of acupuncture leading to bilateral pneumothoraces. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    PubMed

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  16. Simultaneous bilateral elbow dislocation with bilateral medial epicondyle fractures in a 13-year-old female gymnast with hyperlaxity

    PubMed Central

    Bauer, Stefan; Dunne, Ben; Whitewood, Colin

    2012-01-01

    Bilateral simultaneous elbow dislocations are extremely rare and have only been described in 12 cases. In the paediatric population unilateral elbow dislocations are rare with 3–6% of all elbow injuries and there are only few studies describing this injury exclusively in children. There is only one case report of a paediatric patient who sustained a simultaneous bilateral elbow dislocation with medial epicondyle fractures. We present a second paediatric case of simultaneous bilateral elbow dislocation with associated displaced bilateral medial epicondyle fractures in a gymnast with joint hyperlaxity (3 of 5 Wynne-Davies criteria) treated with closed reduction and short-term immobilisation (3 weeks). The patient returned to full trampoline gymnastics between 4 and 5 months postinjury and made an uneventful recovery. PMID:23234820

  17. Report of the key comparison CCQM-K108 determination of arsenic species, total arsenic and cadmium in brown rice flour

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shinichi; Kotzeva, Boriana; Kakoulides, Elias; Sxoina, Vasiliki; Fung, W. H.; Choi, Y. Y.; Yau, H. P.; Tsoi, Y. T.; Lee, C. L.; Kong, M. F.; Shin, Richard; Juan, Wang; Sin Yee, Ng; Uribe, Christian; Marques Rodrigues, Janaína; Caciano de Sena, Rodrigo; Silva Dutra, Emily; Bergamaschi, Luigi; Giordani, Laura; D'Agostino, Giancarlo; Valiente, Liliana; Horvat, Milena; Jacimovic, Radojko; Oduor Okumu, Tom; Kang'Iri, Jacqueline; Owiti Orwa, Tabitha; Chao, Wei; Jingbo, Chao; Taebunpakul, Sutthinun; Yafa, Charun; Kaewkhomdee, Nattikarn; Chailap, Benjamat; Pharat, Yanee; Phukphattanachai, Pranee; Turk, Gregory C.; Long, Stephen; Murphy, K. E.; Davis, Clay; Ellisor, Michael; Merrick, Jeffrey; White, Ian; Saxby, David; Linsky, S. M.; Barzev, A.; Botha, A.

    2015-01-01

    The CCQM-K108 key comparison was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes (NMIs) or designated institutes (DIs) to measure the mass fractions of arsenic species, total arsenic and cadmium in brown rice flour. The National Metrology Institute of Japan (NMIJ) acted as the coordinating laboratory. The participants used different measurement methods, though most of them used inductively coupled plasma mass spectrometry (ICP-MS) or isotope-dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) for Cd and ICP-MS for total arsenic. Regarding arsenic speciation, all participants used ICP-MS coupled with liquid chromatography (LC). Accounting for relative expanded uncertainty, comparability of measurement results for each of total arsenic and cadmium was successfully demonstrated by the participating NMIs or DIs for the measurement of the measurand at the level of less than 0.5 mg/kg. Regarding arsenic species (inorganic arsenic and dimethylarsinic acid (DMAA)), there was, however, a measurement problem still to be solved and that part of CCQM-K108 will be repeated. It is expected that arsenic, cadmium and other metals at mass fractions greater than approximately 0.1 mg/kg in rice flour can be determined by each participant using the same technique(s) employed for this key comparison to achieve similar uncertainties mentioned in the present report. Furthermore, the results of this key comparison can be utilised along with the IAWG core capability approach. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Bilateral coordination and gait symmetry after body-weight supported treadmill training for persons with chronic stroke.

    PubMed

    Combs, Stephanie A; Dugan, Eric L; Ozimek, Elicia N; Curtis, Amy B

    2013-04-01

    Locomotor interventions are commonly assessed using functional outcomes, but these outcomes provide limited information about changes toward recovery or compensatory mechanisms. The study purposes were to examine changes in gait symmetry and bilateral coordination following body-weight supported treadmill training in individuals with chronic hemiparesis due to stroke and to compare findings to participants without disability. Nineteen participants with stroke (>6 months) who ambulated between 0.4 and 0.8 m/s and 22 participants without disability were enrolled in this repeated-measures study. The stroke group completed 24 intervention sessions over 8 weeks with 20 minutes of walking/session. The non-disabled group served as a comparison for describing changes in symmetry and coordination. Bilateral 3-dimensional motion analysis and gait speed were assessed across 3 time points (pre-test, immediate post-test, and 6-month retention). Continuous relative phase was used to evaluate bilateral coordination (thigh-thigh, shank-shank, foot-foot) and gait symmetry was assessed with spatiotemporal ratios (step length, swing time, stance time). Significant improvements in continuous relative phase (shank-shank and foot-foot couplings) were found at post-test and retention for the stroke group. Significant differences in spatiotemporal symmetry ratios were not found over time. Compared to the non-disabled group, changes in bilateral coordination moved in the direction of normal recovery. Most measures of continuous relative phase were more responsive to change after training than the spatiotemporal ratios. After body-weight supported treadmill training, the stroke group made improvements toward recovery of normal bilateral coordination. Bilateral coordination and gait symmetry measures may assess different aspects of gait. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Immediate effects of bilateral manipulation of talocrural joints on standing stability in healthy subjects.

    PubMed

    Alburquerque-Sendín, Francisco; Fernández-de-las-Peñas, César; Santos-del-Rey, Miguel; Martín-Vallejo, Francisco Javier

    2009-02-01

    The purpose of this study was to investigate the immediate effects of bilateral talocrural joint manipulation on standing stability in healthy subjects. Sixty-two healthy subjects, 16 males and 46 females, aged from 18 to 32 years old (mean: 21+/-3 years old) participated in the study. Subjects were randomly divided into two groups: an intervention group (n=32), who received manipulation of bilateral talocrural joints and a control group (n=30) which did not receive any intervention. Baropodometric and stabilometric evaluations were assessed pre- and 5 min post-intervention by an assessor blinded to the treatment allocation. Intra-group and inter-group comparisons were analysed using appropriate parametric tests. The results indicated that changes on the X coordinate range, length of motion, and mean speed approximated to statistical significance (P=0.06), and changes on the Y coordinate range reached statistical significance (P=0.02). Average X and Y motions, and anterior-posterior or lateral velocities did not show significant differences. Our results showed that bilateral thrust manipulation of the talocrural joint did not modify standing stability, that is, the behavioural pattern of the projection of the centre of pressure, in healthy subjects.

  20. Bilateral versus unilateral hearing aids for bilateral hearing impairment in adults.

    PubMed

    Schilder, Anne Gm; Chong, Lee Yee; Ftouh, Saoussen; Burton, Martin J

    2017-12-19

    Acquired hearing loss is common and its incidence increases markedly with age. In most people, 'age-related' hearing loss is sensorineural (due to the loss of cochlear hair cells) and bilateral, affecting both ears to the same degree. Hearing loss categorised as mild, moderate or severe is primarily managed with hearing aids. People with bilateral hearing loss may be offered one aid, fitted to one specific ear, or two aids fitted to both ears. There is uncertainty about the relative benefits to people with hearing loss of these different strategies. To assess the effects of bilateral versus unilateral hearing aids in adults with a bilateral hearing impairment. The Cochrane ENT Information Specialist searched the ENT Trials Register; Cochrane Register of Studies Online; PubMed; Ovid Embase; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 8 June 2017. Randomised controlled trials (RCTs) comparing the fitting of two versus one ear-level acoustic hearing aids in adults (over 18 years) with a bilateral hearing impairment, both ears being eligible for hearing aids. We used the standard methodological procedures expected by Cochrane. Our primary outcomes were patient preference for bilateral or unilateral aids, hearing-specific health-related quality of life and adverse effects (pain or discomfort in the ear, initiation or exacerbation of middle or outer ear infection). Secondary outcomes included: usage of hearing aids (as measured by, for example, data logging or battery consumption), generic health-related quality of life, listening ability and audiometric benefit measured as binaural loudness summation. We used GRADE to assess the quality of the evidence for each outcome; this is indicated in italics. We included four cross-over RCTs with a total of 209 participants, ranging in age from 23 to 85 and with a preponderance of men. All the studies allowed the use of hearing aids for

  1. Bilateral Mandibular Paramolars

    PubMed Central

    Dhull, Rachita Singh; Panda, Swagatika; Acharya, Sonu; Yadav, Shweta; Mohanty, Gatha

    2014-01-01

    ABSTRACT Supernumerary tooth is a developmental anomaly and has been argued to arise from multiple etiologies. These teeth may remain embedded in the alveolar bone or can erupt into the oral cavity. They can cause a variety of complications in the develo­ping dentition. Supernumerary teeth can present in various forms and in any region of the mandible or maxilla, but have a predisposition for the anterior maxilla. Here is the presentation of a case of unusual location of supernumerary teeth located in between mandibular first and second molar region bilaterally. How to cite this article: Dhull KS, Dhull RS, Panda S, Acharya S, Yadav S, Mohanty G. Bilateral Mandibular Paramolars. Int J Clin Pediatr Dent 2014;7(1):40-42. PMID:25206236

  2. Bilateral mandibular paramolars.

    PubMed

    Dhull, Kanika Singh; Dhull, Rachita Singh; Panda, Swagatika; Acharya, Sonu; Yadav, Shweta; Mohanty, Gatha

    2014-01-01

    Supernumerary tooth is a developmental anomaly and has been argued to arise from multiple etiologies. These teeth may remain embedded in the alveolar bone or can erupt into the oral cavity. They can cause a variety of complications in the develo-ping dentition. Supernumerary teeth can present in various forms and in any region of the mandible or maxilla, but have a predisposition for the anterior maxilla. Here is the presentation of a case of unusual location of supernumerary teeth located in between mandibular first and second molar region bilaterally. How to cite this article: Dhull KS, Dhull RS, Panda S, Acharya S, Yadav S, Mohanty G. Bilateral Mandibular Paramolars. Int J Clin Pediatr Dent 2014;7(1):40-42.

  3. Bilateral intraocular calcification in necrotizing cytomegalovirus retinitis.

    PubMed

    Tuncer, Samuray; Oray, Merih; Yildirim, Yeliz; Camcioglu, Yildiz; Tugal-Tutkun, Ilknur

    2014-10-01

    We report a unique case of bilateral intraocular calcification due to necrotizing cytomegalovirus (CMV) retinitis associated with congenital CMV infection. A 7-month-old boy with a history of congenital CMV infection showed bilateral intraocular calcific plaques on computed tomography (CT) and ultrasonography. We reviewed the patient's medical files for the purpose of this report. The patient had a prior medical history of hospitalization for fever and swelling in the neck at 3 months of age. Systemic findings (anemia, neutropenia, hepatosplenomegaly, and reactive lymphadenomegaly) in association with a low CD4 count, high blood CMV viral load, and positivity for urine CMV DNA by polymerase chain reaction led to the diagnosis of bone marrow suppression and congenital CMV infection. At 7 months, he developed horizontal nystagmus and bilateral leukocoria over 20 days. Cranial CT and ultrasonography revealed bilateral intraocular calcific plaques and the patient was referred to rule out retinoblastoma. Fundoscopy was consistent with bilateral hemorrhagic, necrotizing CMV retinitis. Significant resolution of the retinal infiltrations occurred 2 weeks after initiation of systemic treatment with ganciclovir. Intraocular calcification may be a sign of active CMV retinitis. To our knowledge this is the first report of bilateral intraocular calcification serving as the presenting clinical manifestation of necrotizing CMV retinitis.

  4. Coordination between pelvis and shoulder girdle during walking in bilateral cerebral palsy.

    PubMed

    Tavernese, Emanuela; Paoloni, Marco; Mangone, Massimiliano; Castelli, Enrico; Santilli, Valter

    2016-02-01

    Studies revealed that pelvis and shoulder girdle kinematics is impaired in children with the diplegic form of bilateral cerebral palsy while walking. The features of 3D coordination between these segments, however, have never been evaluated. The gait analyses of 27 children with bilateral cerebral palsy (18 males; mean age 124 months) have been retrospectively reviewed from the database of a Movement Analysis Laboratory. The spatial-temporal parameters and the range-of-motions of the pelvis and of the shoulder girdle on the three planes of motion have been calculated. Continuous relative phase has been calculated for the 3D pelvis-shoulder girdle couplings on the transverse, sagittal and frontal planes of motion to determine coordination between these segments. Data from 10 typically developed children have been used for comparison. Children with bilateral cerebral palsy walk with lower velocity (P=0.01), shorter steps (P<0.0001), larger base of support (P<0.01) and increased duration of the double support phase (P=0.005) when compared to typically developed children. The mean continuous relative phase on the transverse plane has been found lower in the cerebral palsy group throughout the gait cycle (P=0.003), as well as in terminal stance, pre-swing and mid-swing. The age, gait speed and pelvis range-of-motions on the transverse plane have been found correlated to continuous relative phase on the transverse plane. Compared with typically developed children, children with bilateral cerebral palsy show a more in-phase coordination between the pelvis and the shoulder girdle on the transverse plane while walking. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Bilateral contact ground reaction forces and contact times during plyometric drop jumping.

    PubMed

    Ball, Nick B; Stock, Christopher G; Scurr, Joanna C

    2010-10-01

    Drop jumping (DJ) is used in training programs aimed to improve lower extremity explosive power. When performing double-leg drop jumps, it is important to provide an equal stimulus to both legs to ensure balanced development of the lower legs. The aim of this study was to bilaterally analyze the ground reactions forces and temporal components of drop jumping from 3 heights. Ten recreationally active male subjects completed 3 bounce-drop jumps from 3 starting heights (0.2, 0.4, and 0.6 m). Two linked force platforms were used to record left- and right-leg peak vertical force, time to peak force, average force, ground contact time, impulse and time differential. Between-height and between-leg comparisons for each variable were made using a multivariate analysis of variance with post hoc Wilcoxon tests (p < 0.05). Results indicated that force and time variables increased as drop jump height increased (p < 0.0001). Post hoc analyses showed that at 0.2- and 0.4-m bilateral differences were present in the time to peak force, average force, and impulse. No bilateral differences for any variables were shown at 0.6-m starting height. The contact time for all jumps was <0.26 seconds. At 0.2 m, only 63% of the subjects had a starting time differential of <0.01 seconds, rising to 96.3% at 0.6 m. The results indicated that 0.6 m is the suggested drop jump height to ensure that no bilateral differences in vertical forces and temporal components occur; however, shorter contact times were found at the lower heights.

  6. Active middle ear implant coupled bilaterally to the round window despite bilateral implanted stapes prostheses.

    PubMed

    Coordes, Annekatrin; Jahreiss, Linda; Schönfeld, Uwe; Lenarz, Minoo

    2017-02-01

    After stapes surgery, patients with mixed or moderate hearing loss have limited possibilities for hearing improvement. We are reporting on a patient who underwent stapedotomy bilaterally 20 years ago and had sensorineural and mixed hearing loss. Recurrent otitis externa prevented the use of hearing aids. This patient was treated bilaterally with the Vibrant Soundbridge (Med-El, Innsbruck, Austria) successively. The Schuknecht piston stapes prostheses remained in situ. The Floating Mass Transducer (FMT; Med-El) was coupled to the round window (RW) and provided good acoustic reinforcement bilaterally. In conclusion, for patients with otosclerosis and stapes surgery, the FMT-RW coupling (Bess AG, Berlin, DE) is a safe procedure with good acoustic amplification. Laryngoscope, 2016 127:500-503, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Management of Bilateral Hemifacial Spasm with Microvascular Decompression.

    PubMed

    Dou, Ning-Ning; Zhong, Jun; Liu, Ming-Xing; Xia, Lei; Sun, Hui; Li, Bin; Li, Shi-Ting

    2016-03-01

    Bilateral hemifacial spasm (HFS) is very rare. The literature contains only 32 clinical reports. Although microvascular decompression (MVD) is widely accepted as effective therapy for HFS, the etiology and surgical treatment of bilateral HFS are seldom addressed. We report our experience with MVD for patients with bilateral HFS. This retrospective report included 10 patients with bilateral HFS. All patients underwent MVD 1 or 2 times and were followed for 5-92 months. The clinical data were retrospectively analyzed. The etiology and treatment strategies were discussed. Spasm stopped completely on the operative side in all 10 patients. Symptoms on the other side also resolved in 3 patients, improved in 1 patient, and did not improve at all in 6 patients. Of the 6 patients with no improvement, 5 underwent another MVD on the contralateral side within 1 year and experienced relief of symptoms, and 1 patient refused the surgery. The neurovascular conflict was found in all the operations. During the follow-up period, no complications of hearing loss or facial palsy and no recurrence were observed. Vascular compression was the cause of bilateral HFS in our patients, and MVD relieved the symptoms. Thus, we recommend MVD for patients with bilateral HFS. A crowded cerebellopontine angle space and easy attrition of the neurovascular interfaces may play important roles in the occurrence of bilateral HFS. For some patients, 1 MVD can resolve bilateral symptoms. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Relationships Between Potentiation Effects After Ballistic Half-Squats and Bilateral Symmetry.

    PubMed

    Suchomel, Timothy J; Sato, Kimitake; DeWeese, Brad H; Ebben, William P; Stone, Michael H

    2016-05-01

    The purposes of this study were to examine the effect of ballistic concentric-only half-squats (COHS) on subsequent squat-jump (SJ) performances at various rest intervals and to examine the relationships between changes in SJ performance and bilateral symmetry at peak performance. Thirteen resistance-trained men performed an SJ immediately and every minute up to 10 min on dual force plates after 2 ballistic COHS repetitions at 90% of their 1-repetition-maximum COHS. SJ peak force, peak power, net impulse, and rate of force development (RFD) were compared using a series of 1-way repeated-measures ANOVAs. The percent change in performance at which peak performance occurred for each variable was correlated with the symmetry index scores at the corresponding time point using Pearson correlation coefficients. Statistical differences in peak power (P = .031) existed between rest intervals; however, no statistically significant pairwise comparisons were present (P > .05). No statistical differences in peak force (P = .201), net impulse (P = .064), and RFD (P = .477) were present between rest intervals. The relationships between changes in SJ performance and bilateral symmetry after the rest interval that produced the greatest performance for peak force (r = .300, P = .319), peak power (r = -.041, P = .894), net impulse (r = -.028, P = .927), and RFD (r = -.434, P = .138) were not statistically significant. Ballistic COHS may enhance SJ performance; however, the changes in performance were not related to bilateral symmetry.

  9. Comparison of T stage, N stage, multifocality, and bilaterality in papillary thyroid carcinoma patients according to the presence of coexisting lymphocytic thyroiditis.

    PubMed

    Park, Jin Young; Kim, Dong Wook; Park, Ha Kyung; Ha, Tae Kwun; Jung, Soo Jin; Kim, Do Hun; Bae, Sang Kyun

    2015-01-01

    This study aimed to assess the relationship between coexisting lymphocytic thyroiditis and T-N stages of papillary thyroid carcinoma (PTC) by histopathological analysis. The study included 653 patients who underwent thyroid surgery for PTC at our hospital. Each case was classified as either Hashimoto's thyroiditis (HT), non-Hashimoto type of lymphocytic thyroiditis (NHLT), or normal according to the histopathology of thyroid parenchyma. Patient age, gender, surgical modality, location, T stage, N stage, multifocality and bilaterality were compared according to the histopathology. The prevalence of coexisting lymphocytic thyroiditis was 25.8% (169/653); HT (7.5%, 49/653) and NHLT (18.3%, 120/653). There were no significant differences in T stage, N stage, multifocality and bilaterality with regard to coexisting lymphocytic thyroiditis, regardless of whether HT and NHLT were considered collectively or discretely. Primary tumor size (p < 0.0001), location (p = 0.0011), N stage (p < 0.0001), multifocality (p < 0.0001) and bilaterality (p < 0.0001) differed significantly according to T stage, and gender (p = 0.0193), primary tumor size (p < 0.0001), T stage (p < 0.0001), multifocality (p < 0.0001) and bilaterality (p < 0.0001) differed significantly according to N stage. PTC patients with coexisting lymphocytic thyroiditis did not differ from those with normal parenchyma in terms of T stage, N stage, multifocality and bilaterality.

  10. A case presentation of bilateral simultaneous Bell's palsy.

    PubMed

    Kilic, Rahmi; Ozdek, Ali; Felek, Sevim; Safak, M Asim; Samim, Erdal

    2003-01-01

    Bilateral simultaneous facial paralysis is an extremely rare clinical entity. Unlike the unilateral form, bilateral facial paralysis seldom falls into Bell's category. It is most often a special finding in a symptom complex of a systemic disease; many of them are potentially life-threatening, and therefore the condition warrants urgent medical intervention. Lyme disease, Guillian-Barre syndrome, Bell's palsy, leukemia, sarcoidosis, bacterial meningitis, syphilis, leprosy, Moebius syndrome, infectious mononucleosis, and skull fracture are the most common cause of bilateral facial paralysis. Here we present a 16-year-old patient with bilateral simultaneous Bell's palsy.

  11. Bilateral vocal cord paralysis secondary to head and neck surgery.

    PubMed

    Tekin, Muhammet; Acar, Gul Ozbilen; Kaytaz, Asim; Savrun, Feray Karaali; Çelik, Melek; Cam, Osman Halit

    2012-01-01

    Even endotracheal intubation could be considered safe in operations under general anesthesia; rarely, it could cause recurrent laryngeal nerve paralysis as a complication. As mentioned in the literature, as a possible reason for this, anterior branches of the recurrent laryngeal nerve in the larynx could suffer from compression between the posteromedial part of the thyroid cartilage and the cuff of the tube. In the literature, unilateral vocal cord paralysis due to endotracheal intubation occurs more frequently in comparison to bilateral vocal cord paralysis. These types of palsies usually totally improve in approximately 6 months. A patient who experienced bilateral vocal cord paralysis in the early postoperative period after undergoing an endotracheal intubation process for general anesthesia and primary partial lip resection and supraomohyoid neck dissection due to lower lip carcinoma is presented in our article. Although vocal cord paralysis occurring after head and neck surgery is first thought as a complication of the surgery, endotracheal intubation should be considered as a possible cause of this paralysis. In relation with this patient, causes, clinical symptoms, and treatment procedures of vocal cord paralysis due to endotracheal intubation are discussed under guidance of the literature.

  12. Bilateral mastoiditis from red tide exposure.

    PubMed

    Honner, Samantha; Kudela, Raphael M; Handler, Ethan

    2012-10-01

    Bilateral mastoiditis in adults has previously been reported only in association with diabetes mellitus or immunocompromised patients. To describe a case of bilateral mastoiditis in a healthy adult and to investigate the etiology. A 53-year-old woman presented to the Emergency Department with bilateral otitis externa and mastoiditis after scuba diving during a harmful algal bloom, commonly known as a "red tide." The levels of coliform bacteria recorded at the time and location of her dive exceeded health regulatory limits and correlate with her atypical culture results. Elevated bacterial counts that result from harmful algal blooms may account for this rare infection. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Virtual water trade and bilateral conflicts

    NASA Astrophysics Data System (ADS)

    De Angelis, Enrico; Metulini, Rodolfo; Bove, Vincenzo; Riccaboni, Massimo

    2017-12-01

    In light of growing water scarcity, virtual water, or the water embedded in key water-intensive commodities, has been an active area of debate among practitioners and academics alike. As of yet, however, there is no consensus on whether water scarcity affects conflict behavior and we still lack empirical research intending to account for the role of virtual water in affecting the odds of militarized disputes between states. Using quantitative methods and data on virtual water trade, we find that bilateral and multilateral trade openness reduce the probability of war between any given pair of countries, which is consistent with the strategic role of this important commodity and the opportunity cost associated with the loss of trade gains. We also find that the substantive effect of virtual water trade is comparable to that of oil and gas, the archetypal natural resources, in determining interstate conflicts' probability.

  14. Bilateral Radial Agenesis in a Cat Treated with Bilateral Ulnocarpal Arthrodesis.

    PubMed

    Bezhentseva, Alla; Singh, Harpreet; Boudrieau, Randy J

    2018-06-20

     This article describes corrective antebrachiocarpal re-alignment and arthrodesis for bilateral radial hemimelia (radial agenesis) in an 8-month-old domestic short-haired cat.  Bilateral forelimb deformity of ulnocarpal varus with complete luxation and rotation of the antebrachiocarpal joint spaces, and joint contracture, was observed. Several carpal bones and metacarpal bones I and II and their associated phalanges were absent. Abnormal ambulation and weight bearing on the dorsolateral part of the manus were present. The deformities were treated by bilateral distal ulnar ostectomy and ulnocarpal arthrodesis using a 2.0-mm locking compression plate applied with hybrid fixation and allograft.  Successful deformity correction was obtained with subsequent fusion of the antebrachiocarpal joints. No complications were observed. At long-term follow-up (4.75 years), there was good-to-excellent functional result, with approximately 15° internal rotation of the right forelimb manus and shortened stride with slight circumduction and lameness. All implants remained stable and continued bone remodelling was present. The cat was assessed to have good-to-excellent short- and long-term functional results with excellent owner satisfaction.  Treatment of radial agenesis in the cat has previously been limited to conservative management or limb amputation. While there are several reports of corrective limb-sparing procedures used to treat dogs, this is the first report of a cat with successful salvage corrective surgery. Schattauer GmbH Stuttgart.

  15. Bilateral Traumatic Globe Luxation with Optic Nerve Transection

    PubMed Central

    Tok, Levent; Tok, Ozlem Yalcin; Argun, Tugba Cakmak; Yilmaz, Omer; Gunes, Alime; Unlu, Elif Nisa; Sezer, Sezgin; Ibisoglu, Seda; Argun, Mehmet

    2014-01-01

    Purpose The purpose of this study was to document clinical findings and management of a patient with bilateral globe luxation and optic nerve transection. Materials and Methods A 25-year-old female patient was admitted to the emergency department with bilateral traumatic globe luxation following a motor vehicle accident. Results Visual acuity testing showed no light perception. The right pupil was dilated and bilaterally did not react to light. The globes were bilaterally intact. A computed tomography scan revealed Le Fort type II fractures, bilateral optic nerve transection and disruption of all extraocular muscles. The globes of the patient were bilaterally reduced into the orbit. However, the patient developed phthisis bulbi in the right eye at month 3. Conclusion Globe luxation presents a dramatic clinical picture, and may lead to the development of severe complications due to the concomitance of complete optic nerve dissection and multiple traumas. Even if the luxated globe is repositioned into the orbit, there is still an increased risk of the development of phthisis due to ischemia. PMID:25606034

  16. A synchronized computational architecture for generalized bilateral control of robot arms

    NASA Technical Reports Server (NTRS)

    Bejczy, Antal K.; Szakaly, Zoltan

    1987-01-01

    This paper describes a computational architecture for an interconnected high speed distributed computing system for generalized bilateral control of robot arms. The key method of the architecture is the use of fully synchronized, interrupt driven software. Since an objective of the development is to utilize the processing resources efficiently, the synchronization is done in the hardware level to reduce system software overhead. The architecture also achieves a balaced load on the communication channel. The paper also describes some architectural relations to trading or sharing manual and automatic control.

  17. Subxiphoid approach for spontaneous bilateral pneumothorax: a case report.

    PubMed

    Fok, Matthew; Karunanantham, Jay; Ali, Jason M; Concina, Serena; Jayakumar, Shruti; Peryt, Adam; Coonar, Aman; Aresu, Giuseppe

    2017-01-01

    The development of video-assisted thoracoscopic surgery (VATS) has contributed to reduced pain and improved recovery following thoracic surgery. However, pain remains a major issue. Patients with bilateral pulmonary pathology requiring operative intervention may have even more pain due to bilateral transthoracic incisions. The recently described uniportal subxiphoid VATS approach provides an opportunity to undertake bilateral thoracic surgery through a single incision that avoids the bilateral intercostal nerve damage caused by transthoracic incision and drainage. Here we report a case of a patient requiring bilateral bullectomy and pleurectomy for the management of pneumothorax that was performed successfully by the subxiphoid VATS approach.

  18. Bilateral adrenal masses: a single-centre experience

    PubMed Central

    Bandgar, Tushar; Khare, Shruti; Jadhav, Swati; Lila, Anurag; Goroshi, Manjunath; Kasaliwal, Rajeev; Khadilkar, Kranti; Shah, Nalini S

    2016-01-01

    Background Bilateral adrenal masses may have aetiologies like hyperplasia and infiltrative lesions, besides tumours. Hyperplastic and infiltrative lesions may have coexisting hypocortisolism. Bilateral tumours are likely to have hereditary/syndromic associations. The data on clinical profile of bilateral adrenal masses are limited. Aims To analyse clinical, biochemical and radiological features, and management outcomes in patients with bilateral adrenal masses. Methods Retrospective analysis of 70 patients with bilateral adrenal masses presenting to a single tertiary care endocrine centre from western India (2002–2015). Results The most common aetiology was pheochromocytoma (40%), followed by tuberculosis (27.1%), primary adrenal lymphoma (PAL) (10%), metastases (5.7%), non-functioning adenomas (4.3%), primary bilateral macronodular adrenal hyperplasia (4.3%), and others (8.6%). Age at presentation was less in patients with pheochromocytoma (33 years) and tuberculosis (41 years) compared with PAL (48 years) and metastases (61 years) (P<0.001). The presenting symptoms for pheochromocytoma were hyperadrenergic spells (54%) and abdominal pain (29%), whereas tuberculosis presented with adrenal insufficiency (AI) (95%). The presenting symptoms for PAL were AI (57%) and abdominal pain (43%), whereas all cases of metastasis had abdominal pain. Mean size of adrenal masses was the largest in lymphoma (5.5cm) followed by pheochromocytoma (4.8cm), metastasis (4cm) and tuberculosis (2.1cm) (P<0.001). Biochemically, most patients with pheochromocytoma (92.8%) had catecholamine excess. Hypocortisolism was common in tuberculosis (100%) and PAL (71.4%) and absent with metastases (P<0.001). Conclusion In evaluation of bilateral adrenal masses, age at presentation, presenting symptoms, lesion size, and biochemical features are helpful in delineating varied underlying aetiologies. PMID:27037294

  19. Patellofemoral arthroplasty in a bilateral Syme's amputee.

    PubMed

    Kanna, Raj; Barrett, David S

    2016-01-01

    We present the case of a 50-year-old woman, who is a bilateral Syme's amputee and subsequently underwent patellofemoral arthroplasty (PFA) for osteoarthritis primarily involving the patellofemoral (PF) joint. History and physical examination were suggestive of severe PF arthritis without patellar instability of the right knee. The diagnosis was confirmed by roentgenogram and a PFA was performed. A slightly modified rehabilitation program was implemented and the patient was followed until 6 years after surgery. In comparison to the preoperative scores, the Oxford, the Western Ontario and McMaster Universities (WOMAC), the Knee Society, and the Hospital for Special Surgery Knee Scores improved significantly (p < 0.05) at the time of final follow-up. PF problems specific to below-knee amputees, factors to be considered before performing PFA, and the drawbacks of other treatment modalities in these patients have been discussed.

  20. Bilateral aniridia lenticular coloboma and snowflake retinal degeneration.

    PubMed

    Doganay, Selim; Emre, Sinan; Firat, Penpegül

    2009-01-01

    A 6-year-old boy presented with bilateral aniridia associated with lens coloboma and snowflake retinal degeneration. Ophthalmologic examination revealed bilateral corneal peripheral epithelial thickening and aniridia. Additionally, the patient had lenticular coloboma and snowflake retinal degeneration in both eyes. Intraocular pressure was 22 mm Hg bilaterally. The patient also had pendular nystagmus. Uncorrected visual acuity was counting fingers at 2 meters for both eyes, but improved to 0.2 and 0.05, respectively, with correction. Congenital aniridia has been reported with various ophthalmic pathologies, but this is the first case to display bilateral lenticular coloboma and snowflake retinal degeneration associated with aniridia.

  1. [Bilateral torticollis].

    PubMed

    Kustos, T; Magdics, M

    1993-12-19

    Bilateral torticollis is a very rare form of a well known deformity i.e. muscular torticollis. This malformation might present a differential diagnostic problem both for orthopaedic surgeons and ophthalmologists, as well as, for neurologists. In agreement with the literature, the role of an injury during labour or defective embriogenesis is suggested to play a part.

  2. Comparison between Unilateral and Bilateral Plyometric Training on Single and Double Leg Jumping Performance and Strength.

    PubMed

    Bogdanis, Gregory C; Tsoukos, Athanasios; Kaloheri, Olga; Terzis, Gerasimos; Veligekas, Panagiotis; Brown, Lee E

    2017-04-18

    This study compared the effects of unilateral and bilateral plyometric training on single and double-leg jumping performance, maximal strength and rate of force development (RFD). Fifteen moderately trained subjects were randomly assigned to either a unilateral (U, n=7) or bilateral group (B, n=8). Both groups performed maximal effort plyometric leg exercises two times per week for 6 weeks. The B group performed all exercises with both legs, while the U group performed half the repetitions with each leg, so that total exercise volume was the same. Jumping performance was assessed by countermovement jumps (CMJ) and drop jumps (DJ), while maximal isometric leg press strength and RFD were measured before and after training for each leg separately and both legs together. CMJ improvement with both legs was not significantly different between U (12.1±7.2%) and B (11.0±5.5%) groups. However, the sum of right and left leg CMJ only improved in the U group (19.0±7.1%, p<0.001) and was unchanged in the B group (3.4±8.4%, p=0.80). Maximal isometric leg press force with both legs was increased similarly between groups (B: 20.1±6.5%, U: 19.9±6.2%). However, the sum of right and left leg maximal force increased more in U compared to B group (23.8±9.1% vs. 11.9±6.2%, p=0.009, respectively). Similarly, the sum of right and left leg RFD0-50 and RFD0-100 were improved only in the U group (34-36%, p<0.01). Unilateral plyometric training was more effective at increasing both single and double-leg jumping performance, isometric leg press maximal force and RFD when compared to bilateral training.

  3. Reinnervation of Bilateral Posterior Cricoarytenoid Muscles Using the Left Phrenic Nerve in Patients with Bilateral Vocal Fold Paralysis

    PubMed Central

    Zheng, Hongliang; Chen, Donghui; Zhu, Minhui; Wang, Wei; Liu, Fei; Zhang, Caiyun

    2013-01-01

    Objective To evaluate the feasibility, effectiveness, and safety of reinnervation of the bilateral posterior cricoarytenoid (PCA) muscles using the left phrenic nerve in patients with bilateral vocal fold paralysis. Methods Forty-four patients with bilateral vocal fold paralysis who underwent reinnervation of the bilateral PCA muscles using the left phrenic nerve were enrolled in this study. Videostroboscopy, perceptual evaluation, acoustic analysis, maximum phonation time, pulmonary function testing, and laryngeal electromyography were performed preoperatively and postoperatively. Patients were followed-up for at least 1 year after surgery. Results Videostroboscopy showed that within 1 year after reinnervation, abductive movement could be observed in the left vocal folds of 87% of patients and the right vocal folds of 72% of patients. Abductive excursion on the left side was significantly larger than that on the right side (P < 0.05); most of the vocal function parameters were improved postoperatively compared with the preoperative parameters, albeit without a significant difference (P > 0.05). No patients developed immediate dyspnea after surgery, and the pulmonary function parameters recovered to normal reference value levels within 1 year. Postoperative laryngeal electromyography confirmed successful reinnervation of the bilateral PCA muscles. Eighty-seven percent of patients in this series were decannulated and did not show obvious dyspnea after physical activity. Those who were decannulated after subsequent arytenoidectomy were not included in calculating the success rate of decannulation. Conclusions Reinnervation of the bilateral PCA muscles using the left phrenic nerve can restore inspiratory vocal fold abduction to a physiologically satisfactory extent while preserving phonatory function at the preoperative level without evident morbidity. PMID:24098581

  4. Bilateral ECT induces bilateral increases in regional cortical thickness.

    PubMed

    van Eijndhoven, P; Mulders, P; Kwekkeboom, L; van Oostrom, I; van Beek, M; Janzing, J; Schene, A; Tendolkar, I

    2016-08-23

    Electroconvulsive therapy (ECT) is the most effective treatment for patients suffering from severe or treatment-resistant major depressive disorder (MDD). Unfortunately its underlying neurobiological mechanisms are still unclear. One line of evidence indicates that the seizures produced by ECT induce or stimulate neuroplasticity effects. Although these seizures also affect the cortex, the effect of ECT on cortical thickness is not investigated until now. We acquired structural magnetic resonance imaging data in 19 treatment-resistant MDD patients before and after a bilateral ECT course, and 16 healthy controls at 2 time points, and compared changes in cortical thickness between the groups. Our results reveal that ECT induces significant, bilateral increases in cortical thickness, including the temporal pole, inferior and middle temporal cortex and the insula. The pattern of increased cortical thickness was predominant in regions that are associated with seizure onset in ECT. Post hoc analyses showed that the increase in thickness of the insular cortex was larger in responders than in non-responders, which may point to a specific relationship of this region with treatment effects of ECT.

  5. A low-complexity geometric bilateration method for localization in Wireless Sensor Networks and its comparison with Least-Squares methods.

    PubMed

    Cota-Ruiz, Juan; Rosiles, Jose-Gerardo; Sifuentes, Ernesto; Rivas-Perea, Pablo

    2012-01-01

    This research presents a distributed and formula-based bilateration algorithm that can be used to provide initial set of locations. In this scheme each node uses distance estimates to anchors to solve a set of circle-circle intersection (CCI) problems, solved through a purely geometric formulation. The resulting CCIs are processed to pick those that cluster together and then take the average to produce an initial node location. The algorithm is compared in terms of accuracy and computational complexity with a Least-Squares localization algorithm, based on the Levenberg-Marquardt methodology. Results in accuracy vs. computational performance show that the bilateration algorithm is competitive compared with well known optimized localization algorithms.

  6. Hummingbirds generate bilateral vortex loops during hovering: evidence from flow visualization

    NASA Astrophysics Data System (ADS)

    Pournazeri, Sam; Segre, Paolo S.; Princevac, Marko; Altshuler, Douglas L.

    2013-01-01

    Visualization of the vortex wake of a flying animal provides understanding of how wingbeat kinematics are translated into the aerodynamic forces for powering and controlling flight. Two general vortex flow patterns have been proposed for the wake of hovering hummingbirds: (1) The two wings form a single, merged vortex ring during each wing stroke; and (2) the two wings form bilateral vortex loops during each wing stroke. The second pattern was proposed after a study with particle image velocimetry that demonstrated bilateral source flows in a horizontal measurement plane underneath hovering Anna's hummingbirds ( Calypte anna). Proof of this hypothesis requires a clear perspective of bilateral pairs of vortices. Here, we used high-speed image sequences (500 frames per second) of C. anna hover feeding within a white plume to visualize the vortex wake from multiple perspectives. The films revealed two key structural features: (1) Two distinct jets of downwards airflow are present under each wing; and (2) vortex loops around each jet are shed during each upstroke and downstroke. To aid in the interpretation of the flow visualization data, we analyzed high-speed kinematic data (1,000 frames per second) of wing tips and wing roots as C. anna hovered in normal air. These data were used to refine several simplified models of vortex topology. The observed flow patterns can be explained by either a single loop model with an hourglass shape or a bilateral model, with the latter being more likely. When hovering in normal air, hummingbirds used an average stroke amplitude of 153.6° (range 148.9°-164.4°) and a wingbeat frequency of 38.5 Hz (range 38.1-39.1 Hz). When hovering in the white plume, hummingbirds used shallower stroke amplitudes ( bar{x} = 129.8°, range 116.3°-154.1°) and faster wingbeat frequencies ( bar{x} = 41.1 Hz, range 38.5-44.7 Hz), although the bilateral jets and associated vortices were observed across the full kinematic range. The plume did not

  7. Hummingbirds generate bilateral vortex loops during hovering: evidence from flow visualization

    NASA Astrophysics Data System (ADS)

    Pournazeri, Sam; Segre, Paolo S.; Princevac, Marko; Altshuler, Douglas L.

    2012-12-01

    Visualization of the vortex wake of a flying animal provides understanding of how wingbeat kinematics are translated into the aerodynamic forces for powering and controlling flight. Two general vortex flow patterns have been proposed for the wake of hovering hummingbirds: (1) The two wings form a single, merged vortex ring during each wing stroke; and (2) the two wings form bilateral vortex loops during each wing stroke. The second pattern was proposed after a study with particle image velocimetry that demonstrated bilateral source flows in a horizontal measurement plane underneath hovering Anna's hummingbirds ( Calypte anna). Proof of this hypothesis requires a clear perspective of bilateral pairs of vortices. Here, we used high-speed image sequences (500 frames per second) of C. anna hover feeding within a white plume to visualize the vortex wake from multiple perspectives. The films revealed two key structural features: (1) Two distinct jets of downwards airflow are present under each wing; and (2) vortex loops around each jet are shed during each upstroke and downstroke. To aid in the interpretation of the flow visualization data, we analyzed high-speed kinematic data (1,000 frames per second) of wing tips and wing roots as C. anna hovered in normal air. These data were used to refine several simplified models of vortex topology. The observed flow patterns can be explained by either a single loop model with an hourglass shape or a bilateral model, with the latter being more likely. When hovering in normal air, hummingbirds used an average stroke amplitude of 153.6° (range 148.9°-164.4°) and a wingbeat frequency of 38.5 Hz (range 38.1-39.1 Hz). When hovering in the white plume, hummingbirds used shallower stroke amplitudes ( bar{x} = 129.8°, range 116.3°-154.1°) and faster wingbeat frequencies ( bar{x} = 41.1 Hz, range 38.5-44.7 Hz), although the bilateral jets and associated vortices were observed across the full kinematic range. The plume did not

  8. Final report on EURAMET.QM-S6/1195: Bilateral comparison of liquefied hydrocarbon mixtures in constant pressure (piston) cylinders

    NASA Astrophysics Data System (ADS)

    Brown, Andrew S.; Downey, Michael L.; Milton, Martin J. T.; van der Veen, Adriaan M. H.; Zalewska, Ewelina T.; Li, Jianrong

    2013-01-01

    Traceable liquid hydrocarbon mixtures are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas) and LNG (liquefied natural gas), thus meeting the needs of an increasingly large European industrial market. The development of traceable liquid hydrocarbon standards by National Measurement Institutes (NMIs) was still at a relatively early stage at the time this comparison was proposed in 2011. NPL and VSL, who were the only NMIs active in this area, had developed methods for the preparation and analysis of such standards in constant pressure (piston) cylinders, but neither laboratory had Calibration and Measurement Capabilities (CMCs) for these mixtures. This report presents the results of EURAMET 1195, the first comparison of liquid hydrocarbon mixtures between NMIs, which assessed the preparation and analytical capabilities of NPL and VSL for these mixtures. The comparison operated between August 2011 and January 2012. Each laboratory prepared a liquid hydrocarbon standard with nominally the same composition and these standards were exchanged for analysis. The results of the comparison show a good agreement between the laboratories' results and the comparison reference values for the six components with amount fractions greater than 1.0 cmol/mol (propane, propene, iso-butene, n-butane, iso-butane and 1-butene). Measurement of the three components with lower amount fractions (1,3-butadiene, iso-pentane and n-pentane) proved more challenging. In all but one case, the differences from the comparison reference values for these three components were greater than the expanded measurement uncertainty. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual

  9. Final report on key comparison CCAUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Avison, Janine; Barham, Richard

    2014-01-01

    This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Inherited congenital bilateral atresia of the external auditory canal, congenital bilateral vertical talus and increased interocular distance.

    PubMed

    Rasmussen, N; Johnsen, N J; Thomsen, J

    1979-01-01

    Six out of twenty descendants of a reportedly affected grandfather have congenital bilateral symmetrical and isolated subtotal atresia of the external auditory canal. Four of the six affected descendants have bilateral foot anomalies--two affected cousins having congenital vertical talus. All of the three affected boys in the third generation have increased interocular distance. Short fifth fingers, bilateral single transverse palmar creases, pyloric stenosis and congenital exotropia were found infrequently and are considered coincidental features. Apart from the atresia, oto-rhinolaryngologic examination, mental function, dermatoglyphics, IgA, kidney function and heart function of the affected descendants were all normal. The karyotype of four affected descendants examined was normal. An autosomal dominant inheritance with variable expressivity is suggested.

  11. Bilateral stress fracture of the fibulae and periostitis of the tibiae.

    PubMed

    Tsuchie, Hiroyuki; Okada, Kyoji; Nagasawa, Hiroyuki; Chida, Shuichi; Shimada, Yoichi

    2010-01-01

    This study describes a unique case of bilateral stress fractures of the fibulae and provides a literature review. A 16-year-old female badminton player presented with pain around the bilateral distal lateral legs. She had mild bilateral varus deformity at the knee joint, and the bilateral ankles showed valgus deformity in standing posture. Radiographs and computed tomography showed periosteal reactions on the bilateral distal fibulae. Technetium-99m bone scintigraphy demonstrated increased uptake in the bilateral distal fibulae and the bilateral middle third of the tibiae. A diagnosis of bilateral distal fibular stress fractures was made. She was advised to stop playing badminton until the symptoms disappeared. Varus deformity of the knee and valgus deformity of the ankle may have influenced the mechanism underlying bilateral symmetric stress fractures. Copyright © 2010 S. Karger AG, Basel.

  12. Quantum key distribution with finite resources: Secret key rates via Renyi entropies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abruzzo, Silvestre; Kampermann, Hermann; Mertz, Markus

    A realistic quantum key distribution (QKD) protocol necessarily deals with finite resources, such as the number of signals exchanged by the two parties. We derive a bound on the secret key rate which is expressed as an optimization problem over Renyi entropies. Under the assumption of collective attacks by an eavesdropper, a computable estimate of our bound for the six-state protocol is provided. This bound leads to improved key rates in comparison to previous results.

  13. Final report on EURAMET.QM-S10/1274: supplementary comparison of preparative capabilities for automotive gas mixtures

    NASA Astrophysics Data System (ADS)

    Val'ková, M.; Ďurišová, Z.; Szilágyi, Z. N.; Büki, T.; Fükű, J.

    2016-01-01

    This bilateral supplementary preparative comparison involves standard gas mixtures of automotive gas containing carbon monoxide, carbon dioxide and propane in nitrogen. Two laboratories (SMU, Slovakia and MKEH, Hungary) participated in this supplementary comparison. SMU was the coordinating laboratory, responsible for collecting and reporting measurement results. The participants have established facilities for automotive gas gravimetric preparation and analysis. The agreement of the results in this supplementary comparison is good. All the results with their reported uncertainties are in agreement with the reference values for the participants. SMU participated and obtained good results in the previous preparative comparison organised within EURAMET in this field. Both laboratories have existing claims for their Calibration and Measurement Capabilities (CMCs) for automotive gas mixtures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Can foam sclerotherapy be used to safely treat bilateral varicose veins?

    PubMed

    Bhogal, R H; Moffat, C E; Coney, P; Nyamekye, I K

    2012-02-01

    We assessed the use of ultrasound guided foam sclerotherapy (UGFS) to treat bilateral varicose veins either as synchronous or interval procedures. We specifically assessed total foam volume usage and its influence on early outcome and complications. We reviewed our prospectively compiled computerised database of patients with bilateral varicose veins who have undergone UGFS. Duplex findings, foam volumes used and clinical outcome were assessed. One hundred and twelve patients had undergone UGFS for bilateral varicose veins. Sixty-one had bilateral UGFS (122 legs) and 51 had interval UGFS (102 legs). Seventy-eight percent bilateral and 60% interval procedures were for single trunk disease. Median foam volumes per treatment episode were: 17.5 mls bilateral, and 10 mls interval FS. At two weeks 81% of legs had complete occlusion after bilateral UGFS compared to 70% after interval UGFS. One patient in the bilateral UGFS developed transient visual disturbance. There was no systemic complications in the interval UGFS. Bilateral foam sclerotherapy treatment did not adversly affect vein occlusion rates and there was no significant difference in complication rates between the two groups. Bilateral UGFS can be safely performed in selected patient presenting with bilateral varicose veins.

  15. Report of the key-comparison of spectral diffuse reflectance (EURAMET.PR-K5) (Ref. 619)

    NASA Astrophysics Data System (ADS)

    Andor, György; Gál, Péter

    2018-01-01

    This report details the final results of the EURAMET comparison on regular spectral transmittance carried out between 2006 and 2016. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 780 nm at 20 nm increment. We used a star type comparison: first the participants sent their samples to the pilot, than the pilot measured all the samples of the participants and sent them back. The participants measured the samples and sent them to the pilot for control measurement. Six standards were used as reference standards in order to maintain the scale during the comparison. These were three samples of BCR-406 opal glasses (BCR 30506; BCR 30303; BCR 30704), an MC20 Russian opal glass (MC 4777) and two samples made of pressed halon (polytetrafluoroethylene) powder (halon 2007A; halon 2007C). These six samples were designated as the Comparison reference standards. The diffuse reflectance was initially measured on the OMH (BFKH) absolute reflectometer. The link to the CCPR-K5 results was BFKH, and the check on BFKH was the PTB results who also participated in the CCPR-K5 comparison. The participants were GUM, INM, LNE, METAS, BFKH, PTB, SP. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. KEY COMPARISON: Final report on CCQM-K44: Trace elements in sewage sludge

    NASA Astrophysics Data System (ADS)

    Aregbe, Y.; Taylor, P. D. P.

    2009-01-01

    CCQM-K44 was an activity of the Inorganic Analysis Working Group (IAWG) of CCQM and was coordinated by the Joint Research Centre-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) of the European Commission (EC). In CCQM-K44 the amount contents of Cd, Cr, Cu, Pb, Hg, Ni and Zn in sewage sludge were the measurands under investigation. Results were reported by six national metrology institutes (NMIs). During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and agreed on. The final report was submitted in June 2006. After the final report had been submitted to the CCQM in June 2006 the coordinating laboratory was informed that MIRS/IJS was not a designated institute and therefore could not represent the Slovenian NMI in CCQM-K44. This was contrary to what MIRS confirmed to the coordinating laboratory at the beginning of CCQM-K44. After several discussions between MIRS and the CCQM the coordinating laboratory was asked to amend the final report accordingly. In this revised version of the CCQM-K44 final report the results of MIRS/IJS were taken out of CCQM-K44 and included in the pilot study CCQM-P70, which was organised in parallel to CCQM-K44. Due to the limited number of participants compared to previous key comparisons the mixture model median (MM-median) of all reported results could not be applied as KCRV for all the measurands. During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and first agreed on. As a result the final report and degrees of equivalence were finalised and submitted to the CCQM. Subsequent discussions between the IAWG and the CCQM were held, resulting in a different approach as proposed by the coordinating laboratory. Particularly Maurice Cox from NPL recommended the weighted mean and its standard uncertainty (k = 1) as KCRV

  17. One antenna, two antennae, big antennae, small: total antennae length, not bilateral symmetry, predicts odor-tracking performance in the American cockroach Periplaneta americana.

    PubMed

    Lockey, Jacob K; Willis, Mark A

    2015-07-01

    Determining the location of a particular stimulus is often crucial to an animal's survival. One way to determine the local distribution of an odor is to make simultaneous comparisons across multiple sensors. If the sensors detect differences in the distribution of an odor in space, the animal can then steer toward the source. American cockroaches, Periplaneta americana, have 4 cm long antennae and are thought to track odor plumes using a spatial sampling strategy, comparing the amount of odor detected between these bilateral sensors. However, it is not uncommon for cockroaches to lose parts of their antennae and still track a wind-borne odor to its source. We examined whether bilateral odor input is necessary to locate an odor source in a wind-driven environment and how the loss of increasing lengths of the antennae affects odor tracking. The tracking performances of individuals with two bilaterally symmetrical antennae of decreasing length were compared with antennal length-matched individuals with one antenna. Cockroaches with one antenna were generally able to track an odor plume to its source. In fact, the performances of unilaterally antennectomized individuals were statistically identical to those of their bilaterally symmetrical counterparts when the combined length of both antennae equaled the length of the single antenna of the antennectomized individuals. This suggests that the total length of available antennae influences odor tracking performance more than any specific piece of antenna, and that they may be doing something more complex than a simple bilateral comparison between their antennae. The possibility of an antenna-topic map is discussed. © 2015. Published by The Company of Biologists Ltd.

  18. A case of bilateral otomycosis associated with Aspergillus flavus and A. terreus in Taiwan.

    PubMed

    Kirschner, R; Sun, P-L; Huang, S-L; Chen, C-L; Yang, C-P

    2017-09-01

    Otitis externa caused by fungi (otomycosis) occurs more commonly in tropical areas with high moisture than in temperate regions. Bilateral otomycosis is, however, rarely reported. In a case of bilateral otitis externa in a 56-year-old male patient in Taiwan, direct microscopic examination of the cerumen as well as isolation of strains indicated the presence of two Aspergillus species being different in each of both ears. The species were identified by DNA sequence comparisons and additional morphological confirmation of diagnostic characteristics as Aspergillus flavus and Aspergillus terreus. The rarely reported occurrence of two Aspergillus species in otitis of the same patient deserves attention in other cases of otomycosis, particularly with respect to potentially different resistances of different species against antifungals. Treatment with nystatin/neomycin was not successful, but with clotrimazole was effective. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Comparison between bilateral cochlear implants and Neurelec Digisonic(®) SP Binaural cochlear implant: speech perception, sound localization and patient self-assessment.

    PubMed

    Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René

    2013-01-01

    An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.

  20. Bilateral Ramsay Hunt syndrome in a diabetic patient.

    PubMed

    Syal, Rajan; Tyagi, Isha; Goyal, Amit

    2004-12-02

    BACKGROUND: Herpes zoster oticus accounts for about 10% cases of facial palsy, which is usually unilateral and complete and full recovery occurs in only about 20% of untreated patients. Bilateral herpes zoster oticus can sometime occur in immunocompromised patients, though incidence is very rare. CASE PRESENTATION: Diabetic male, 57 year old presented to us with bilateral facial palsy due to herpes zoster oticus. Patient was having bilateral mild to moderate sensorineural hearing loss. Patient was treated with appropriate metabolic control, anti-inflammatory drugs and intravenous acyclovir. Due to uncontrolled diabetes, glucocorticoids were not used in this patient. Significant improvement in hearing status and facial nerve functions were seen in this patient. CONCLUSIONS: Herpes zoster causes severe infections in diabetic patients and can be a cause of bilateral facial palsy and bilateral Ramsay Hunt syndrome. Herpes zoster in diabetic patients should be treated with appropriate metabolic control, NSAIDS and intravenous acyclovir, which we feel should be started at the earliest. Glucocorticoids should be avoided in diabetic patients.

  1. Infectious mononucleosis presenting as bilateral acute dacryocystitis.

    PubMed Central

    Atkinson, P L; Ansons, A M; Patterson, A

    1990-01-01

    A case of infectious mononucleosis presenting as bilateral acute dacryocystitis in a 7-year-old girl is reported. Acute dacryocystitis is uncommon in this age group, and an underlying systemic illness should be suspected particularly when it is bilateral. Images PMID:2275940

  2. SU-E-T-18: A Comparison of Planning Techniques for Bilateral Reconstructed Chest Wall Patients Undergoing Whole Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volpe, T; Margiasso, R; Saleh, Z

    2015-06-15

    Purpose: As we continuously see more bilateral reconstructed chest wall cases, new challenges are being presented to deliver left-sided breast irradiation. We herein compare three Deep Inspiration Breath Hold (DIBH) planning techniques (tangents, VMAT, and IMRT) and two free breathing techniques (VMAT and IMRT). Methods: Three left-sided chest wall patients with bilateral implants were studied. Tangents, VMAT, and IMRT plans were created for DIBH scans. VMAT and IMRT plans were created for free breathing scans. All plans were normalized so that 95% of the prescription dose was delivered to 95% of the planning target volume (PTV). The maximum point dosemore » was constrained to less than 120% of the prescription dose. Since the success of DIBH delivery largely depends on patient’s ability to perform consistent breath hold during beam on time, smaller number of Monitor Units (MU) is in general desired. For each patient, the following information was collected to compare the planning techniques: heart mean dose, left and right lung V20 Gy, contra-lateral (right) breast mean dose, cord max dose, and MU. Results: The average heart mean dose over all patients are 1561, 692, 985, 1245, and 1121 cGy, for DIBH tangents, VMAT, IMRT, free breathing VMAT and IMRT, respectively. For left lung V20 are 60%, 28%, 26%, 30%, and 29%. For contra-lateral breast mean dose are 244, 687, 616, 783, 438 cGy. MU are 253, 853, 2048, 1035, and 1874 MUs. Conclusion: In the setting of bilateral chest wall reconstruction, opposed tangent beams cannot consistently achieve desired heart and left lung sparing. DIBH consistently achieves better healthy tissue sparing. VMAT appears to be preferential to IMRT for planning and delivering radiation to patients with bilaterally reconstructed chest walls being treated with DIBH.« less

  3. Differences Between Bilateral Adrenal Incidentalomas and Unilateral Lesions.

    PubMed

    Pasternak, Jesse D; Seib, Carolyn D; Seiser, Natalie; Tyrell, J Blake; Liu, Chienying; Cisco, Robin M; Gosnell, Jessica E; Shen, Wen T; Suh, Insoo; Duh, Quan-Yang

    2015-10-01

    Adrenal incidentalomas are found in 1% to 5% of abdominal cross-sectional imaging studies. Although the workup and management of unilateral lesions are well established, limited information exists for bilateral incidentalomas. To compare the natural history of patients having bilateral incidentalomas with those having unilateral incidentalomas. Retrospective analysis of a prospective database of consecutive patients referred to an academic multidisciplinary adrenal conference. The setting was a tertiary care university hospital among a cohort of 500 patients with adrenal lesions between July 1, 2009, and July 1, 2014. Prevalence, age, imaging characteristics, biochemical workup, any intervention, and final diagnosis. Twenty-three patients with bilateral incidentalomas and 112 patients with unilateral incidentalomas were identified. The mean age at diagnosis of bilateral lesions was 58.7 years. The mean lesion size was 2.4 cm on the right side and 2.8 cm on the left side. Bilateral incidentalomas were associated with a significantly higher prevalence of subclinical Cushing syndrome (21.7% [5 of 23] vs 6.2% [7 of 112]) (P = .009) and a significantly lower prevalence of pheochromocytoma (4.3% [1 of 23] vs 19.6% [22 of 112]) (P = .003) compared with unilateral lesions, while rates of hyperaldosteronism were similar in both groups (4.3% [1 of 23] vs 5.4% [6 of 112]) (P > .99). Only one patient with bilateral incidentalomas underwent unilateral resection. The mean follow-up was 4 years (range, 1.2-13.0 years). There were no occult adrenocortical carcinomas. Bilateral incidentalomas are more likely to be associated with subclinical Cushing syndrome and less likely to be pheochromocytomas. Although patients with bilateral incidentalomas undergo a workup similar to that in patients with unilateral lesions, differences in their natural history warrant a greater index of suspicion for subclinical Cushing syndrome.

  4. CCQM-K104 key comparison (avermectin B1a) on the characterization of organic substances for chemical purity

    NASA Astrophysics Data System (ADS)

    Dai, Xinhua; Zhang, Wei; Li, Hongmei; Huang, Ting; Li, Mengwan; Quan, Can; Zhang, Qinghe; Davies, Stephen R.; Warren, John; Lo, Man-fung; Kakoulides, Elias; Ceyhan Gören, Ahmet; Marbumrung, Sornkrit; Pfeifer, Dietmar; Ün, İlker; Gündüz, Simay; Yilmaz, Hasibe; Kankaew, Pornhatai; Sudsiri, Nittaya; Shearman, Kittiya; Pookrod, Preeyaporn; Polzer, Joachim; Radeck, Wolfgang

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K104, was coordinated by the National Institute of Metrology (NIM). The comparison was designed to demonstrate a laboratory's performance in determining the mass fraction of the main component in a complex high purity organic material. Nine NMIs or DIs participated in the comparison. Eight participants reported their results. An additional impurity was resolved from the avermectin B1a peak and was tentatively identified as an unknown impurity by NMIA (National Measurement Institute (Australia)). It was subsequently identified by NIM as a diastereoisomer of avermectin B1a at the C-26 position. Final reference value (KCRV) = 924.63 mg/g, with uncertainty (k=1) = 3.89 mg/g, and expanded uncertainty = 8.97 mg/g. The degrees of equivalence with the avermectin B1a KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of high structural complexity (relative molecular mass range of 500 Da -1000 Da and low polarity (-log KOW <= -2). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Similarity in Bilateral Isolated Internal Orbital Fractures.

    PubMed

    Chen, Hung-Chang; Cox, Jacob T; Sanyal, Abanti; Mahoney, Nicholas R

    2018-04-13

    In evaluating patients sustaining bilateral isolated internal orbital fractures, the authors have observed both similar fracture locations and also similar expansion of orbital volumes. In this study, we aim to investigate if there is a propensity for the 2 orbits to fracture in symmetrically similar patterns when sustaining similar trauma. A retrospective chart review was performed studying all cases at our institution of bilateral isolated internal orbital fractures involving the medial wall and/or the floor at the time of presentation. The similarity of the bilateral fracture locations was evaluated using the Fisher's exact test. The bilateral expanded orbital volumes were analyzed using the Wilcoxon signed-rank test to assess for orbital volume similarity. Twenty-four patients with bilateral internal orbital fractures were analyzed for fracture location similarity. Seventeen patients (70.8%) had 100% concordance in the orbital subregion fractured, and the association between the right and the left orbital fracture subregion locations was statistically significant (P < 0.0001). Fifteen patients were analyzed for orbital volume similarity. The average orbital cavity volume was 31.2 ± 3.8 cm on the right and 32.0 ± 3.7 cm on the left. There was a statistically significant difference between right and left orbital cavity volumes (P = 0.0026). The data from this study suggest that an individual who suffers isolated bilateral internal orbital fractures has a statistically significant similarity in the location of their orbital fractures. However, there does not appear to be statistically significant similarity in the expansion of the orbital volumes in these patients.

  6. Patellofemoral arthroplasty in a bilateral Syme's amputee

    PubMed Central

    Kanna, Raj; Barrett, David S.

    2016-01-01

    We present the case of a 50-year-old woman, who is a bilateral Syme's amputee and subsequently underwent patellofemoral arthroplasty (PFA) for osteoarthritis primarily involving the patellofemoral (PF) joint. History and physical examination were suggestive of severe PF arthritis without patellar instability of the right knee. The diagnosis was confirmed by roentgenogram and a PFA was performed. A slightly modified rehabilitation program was implemented and the patient was followed until 6 years after surgery. In comparison to the preoperative scores, the Oxford, the Western Ontario and McMaster Universities (WOMAC), the Knee Society, and the Hospital for Special Surgery Knee Scores improved significantly (p < 0.05) at the time of final follow-up. PF problems specific to below-knee amputees, factors to be considered before performing PFA, and the drawbacks of other treatment modalities in these patients have been discussed. PMID:26908975

  7. KEY COMPARISON: CCQM-K28: Tributyltin in sediment

    NASA Astrophysics Data System (ADS)

    Wolff Briche, Céline S. J.; Wahlen, Raimund; Sturgeon, Ralph E.

    2006-01-01

    Key comparison CCQM K-28 was undertaken to assess the measurement capabilities for quantitation of (C4H9)3Sn+ (TBT) in a prepared marine sediment by National Metrology Institutes (NMIs), which are members of the Comité Consultatif pour la Quantité de Matière (CCQM). It follows a previous pilot study, CCQM-P18. [1, 2] This exercise was sanctioned by the 8th CCQM meeting, 18-19 April 2002, as an activity of the Inorganic Analysis Working Group and was jointly coordinated by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and LGC, UK. Eight NMIs initially indicated their interest, with seven ultimately submitting their results. All NMIs relied on isotope dilution mass spectrometry using a species-specific 117Sn-enriched TBT standard, which was supplied by LGC. No analytical methodology was prescribed for this study. As a result, a variety of extraction approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with ethylation and direct sampling. Detection techniques included ICP-MS (coupled to GC or HPLC for the separation of Sn species) and GC-MS. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  8. Distributional Preferences, Reciprocity-Like Behavior, and Efficiency in Bilateral Exchange

    PubMed Central

    Benjamin, Daniel J.

    2014-01-01

    Under what conditions do distributional preferences, such as altruism or a concern for fair outcomes, generate efficient trade? I analyze theoretically a simple bilateral exchange game: each player sequentially takes an action that reduces his own material payoff but increases the other player’s. Each player’s preferences may depend on both his/her own material payoff and the other player’s. I identify two key properties of the second-mover’s preferences: indifference curves kinked around “fair” material-payoff distributions, and materials payoffs entering preferences as “normal goods.” Either property can drive reciprocity-like behavior and generate a Pareto efficient outcome. PMID:25664144

  9. Fibromuscular Dysplasia Presenting with Bilateral Renal Infarction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doody, O., E-mail: orla_doody@hotmail.co; Adam, W. R.; Foley, P. T.

    2009-03-15

    Fibromuscular dysplasia (FMD) describes a group of conditions which cause nonatheromatous arterial stenoses, most commonly of the renal and carotid arteries, typically in young women. We report a rare case of bilateral segmental renal infarction secondary to FMD in a young male patient. His initial presentation with loin pain and pyrexia resulted in a delay in the definitive diagnosis of FMD. He was successfully treated with bilateral balloon angioplasty. The delayed diagnosis in this patient until the condition had progressed to bilateral renal infarcts highlights the need for prompt investigation and diagnosis of suspected cases of FMD.

  10. [A girl with bilateral periorbital edema].

    PubMed

    Garrelfs, Mark R; Romeijn, Jeroen R M; Heynens, Jan W C M

    2015-01-01

    An 11-year-old girl was seen with painless, bilateral periorbital edema, that had appeared a week before presentation. Additional symptoms included fever, headache and malaise. Serological tests performed three days later showed an active Epstein-Barr virus infection, which provided the diagnosis 'Pfeiffer's disease'. Bilateral periorbital edema can be the presenting manifestation of Epstein-Barr virus infection and should therefore be included in its differential diagnosis.

  11. NIST-NRC Comparison of Total Immersion Liquid-in-Glass Thermometers

    NASA Astrophysics Data System (ADS)

    Hill, K. D.; Gee, D. J.; Cross, C. D.; Strouse, G. F.

    2009-02-01

    The use of liquid-in-glass (LIG) thermometers is described in many documentary standards in the fields of environmental testing, material testing, and material transfer. Many national metrology institutes, including the National Institute of Standards and Technology (NIST) and the National Research Council of Canada (NRC), list calibration services for these thermometers among the Calibration Measurement Capabilities of Appendix C of the BIPM Key Comparison Database. NIST and NRC arranged a bilateral comparison of a set of total-immersion ASTM-type LIG thermometers to validate their uncertainty claims. Two each of ASTM thermometer types 62C through 69C were calibrated at NIST and at NRC at four temperatures distributed over the range appropriate to each thermometer, in addition to the ice point. Collectively, the thermometers span a temperature range of - 38 °C to 305 °C. In total, 160 measurements (80 pairs) comprise the comparison data set. Pair-wise differences ( T NIST- T NRC) were formed for each thermometer at each temperature. For 8 of the 80 pairs (10 %), the differences exceed the k = 2 combined uncertainties. These results support the claimed capabilities of NIST and NRC for the calibration of LIG thermometers.

  12. Noise reduction with complex bilateral filter.

    PubMed

    Matsumoto, Mitsuharu

    2017-12-01

    This study introduces a noise reduction technique that uses a complex bilateral filter. A bilateral filter is a nonlinear filter originally developed for images that can reduce noise while preserving edge information. It is an attractive filter and has been used in many applications in image processing. When it is applied to an acoustical signal, small-amplitude noise is reduced while the speech signal is preserved. However, a bilateral filter cannot handle noise with relatively large amplitudes owing to its innate characteristics. In this study, the noisy signal is transformed into the time-frequency domain and the filter is improved to handle complex spectra. The high-amplitude noise is reduced in the time-frequency domain via the proposed filter. The features and the potential of the proposed filter are also confirmed through experiments.

  13. Bilateral Medial Medullary Infarction with Nondominant Vertebral Artery Occlusion.

    PubMed

    Zhang, Lei; Zhang, Gui-lian; Du, Ju-mei; Ma, Zhu-lin

    2015-09-01

    Bilateral medial medullary infarction (MMI) is a rare stroke subtype. Here, we report a case with bilateral MMI caused by nondominant vertebral artery occlusion confirmed by brain digital subtraction angiography and magnetic resonance imaging basi-parallel-anatomical-scanning. We highlight that anterior spinal arteries could originate from a unilateral vertebral artery (VA). Radiologists and neurologists should pay attention to the nondominant VA as bilateral MMI may be induced by occlusion of nondominant VA that supplies the bilateral anteromedial territories of the medulla. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Bilateral nasolabial cysts associated with recurrent dacryocystitis.

    PubMed

    Kyrmizakis, Dionysios E; Lachanas, Vassilios A; Benakis, Antonios A; Velegrakis, George A; Aslanides, Ioannis M

    2005-05-01

    Nasolabial cysts are rare, nonodontogenic, soft-tissue, developmental cysts occurring inferior to the nasal alar region. They are thought to arise from remnants of the nasolacrimal ducts and they are frequently asymptomatic. We report a rare case of bilateral nasolabial cysts accompanied by bilateral chronic dacryocystitis. A 48-year-old woman suffering from bilateral chronic dacryocystitis was referred to our department for endonasal dacryocystorhinostomy. She had undergone external dacryocystorhinostomy on the left side a few years earlier. Physical examination and computed tomography scan revealed nasolabial cysts bilaterally inferior to the nasal alar region. The cysts were removed via a sublabial approach and endoscopic dacryocystorhinostomy was performed on the right side. Ten months after surgery, the patient was asymptomatic. There may be a correlation, due to embryological reasons, between the presence of nasolabial cysts and the presence of chronic dacryocystitis. Both can be corrected surgically, under the same anaesthesia, without visible scar formation.

  15. The behavioral implications of the bilateral gamma process

    NASA Astrophysics Data System (ADS)

    Xie, Haibin; Wang, Shouyang; Lu, Zudi

    2018-06-01

    Bilateral gamma process is widely used in risk management and asset pricing. However the behavioral implications of this process remain unknown. This paper investigates this problem for the first time within the framework of Tauchen and Pitts (1983). With the assumption that there are two types of traders in the market, the optimistic and the pessimistic, we find the bilateral gamma process can be derived from Walrasian equilibrium. This finding establishes the microstructure foundations for the bilateral gamma process.

  16. Bilateral calcaneal epiphysiolysis in a dog.

    PubMed

    Font, J; Pèlach, M; Font, C; Cairo, J

    2013-01-01

    A case of bilateral calcaneal epiphysiolysis in a six-month-old female Dobermann Pinscher is described in this report. The absence of a traumatic event and the clinical, radiographic and histopathological abnormalities led us to the diagnosis of simultaneous bilateral epiphysiolysis of the calcaneus. A tension band and a type II transarticular external fixator were placed. The clinical signs were resolved only temporarily because of the gravity of the bone changes.

  17. Bilateral medial medullary infarction: a systematic review.

    PubMed

    Pongmoragot, Jitphapa; Parthasarathy, Sujatha; Selchen, Daniel; Saposnik, Gustavo

    2013-08-01

    Bilateral infarction of the medial medulla (MMI) is rare. Limited information is available on clinical characteristics, etiology, and prognosis. High-resolution neuroimaging has a major role in elucidating the underlying stroke mechanism. The aim of this systematic review was to analyze the clinical presentations, stroke mechanisms, and outcomes in patients with bilateral MMI. We performed a systematic review of the literature from 1992-2011 that reported on clinical presentations, stroke mechanism, and/or outcomes in patients with magnetic resonance imaging-proven bilateral MMI. Medline, EMBASE, and Web of Science Scholars Portal were searched without language restriction. Two reviewers independently assessed identified studies to determine eligibility, validity, and quality. The primary outcome was inpatient mortality; a secondary outcome was case fatality at 12 months. We identified 138 articles from Medline, EMBASE, and Scholars Portal including the MeSH terms "brainstem infarction," "medulla," and "bilateral." Twenty-nine articles met our inclusion criteria, including a total of 38 cases with bilateral MMI, and included in our study. These 38 patients had a mean age of 62.2 years and were predominately male (74.2%). The most common clinical presentations were motor weakness in 78.4%, dysarthria in 48.6%, and hypoglossal palsy in 40.5%. The most common vascular pathology was vertebral artery atherosclerosis, in 38.5%. The clinical outcome was poor (mortality, 23.8%; dependency, 61.9%). Bilateral medial medullary infarction is a rare stroke syndrome. Clinical presentations were mostly rostral medullary lesions. Large-artery atherosclerosis and branch disease were the most common stroke mechanisms. The clinical outcome was usually poor. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  18. Bilateral tympanokeratomas (cholesteatomas) with bilateral otitis media, unilateral otitis interna and acoustic neuritis in a dog.

    PubMed

    Østevik, Liv; Rudlang, Kathrine; Holt Jahr, Tuva; Valheim, Mette; Njaa, Bradley Lyndon

    2018-05-22

    An aural cholesteatoma, more appropriately named tympanokeratoma, is an epidermoid cyst of the middle ear described in several species, including dogs, humans and Mongolian gerbils. The cyst lining consists of stratified, keratinizing squamous epithelium with central accumulation of a keratin debris. This case report describes vestibular ganglioneuritis and perineuritis in a dog with chronic otitis, bilateral tympanokeratomas and presumed extension of otic infection to the central nervous system. An 11-year-old intact male Dalmatian dog with chronic bilateral otitis externa and sudden development of symptoms of vestibular disease was examined. Due to the dog's old age the owner opted for euthanasia without any further examination or treatment and the dog was submitted for necropsy. Transection of the ears revealed grey soft material in the external ear canals and pearly white, dry material consistent with keratin in the tympanic bullae bilaterally. The brain and meninges were grossly unremarkable. Microscopical findings included bilateral otitis externa and media, unilateral otitis interna, ganglioneuritis and perineuritis of the spiral ganglion of the vestibulocochlear nerve and multifocal to coalescing, purulent meningitis. A keratinizing squamous epithelial layer continuous with the external acoustic meatus lined the middle ear compartments, consistent with bilateral tympanokeratomas. Focal bony erosion of the petrous portion of the temporal bone and squamous epithelium and Gram-positive bacterial cocci were evident in the left cochlea. The findings suggest that meningitis developed secondary to erosion of the temporal bone and ganglioneuritis and/or perineuritis of the vestibulocochlear nerve. Middle ear tympanokeratoma is an important and potentially life-threatening otic condition in the dog. Once a tympanokeratoma has developed expansion of the cyst can lead to erosion of bone and extension of otic infection to the inner ear, vestibulocochlear ganglion and

  19. Bilateral Ramsay Hunt syndrome in a diabetic patient

    PubMed Central

    Syal, Rajan; Tyagi, Isha; Goyal, Amit

    2004-01-01

    Background Herpes zoster oticus accounts for about 10% cases of facial palsy, which is usually unilateral and complete and full recovery occurs in only about 20% of untreated patients. Bilateral herpes zoster oticus can sometime occur in immunocompromised patients, though incidence is very rare. Case presentation Diabetic male, 57 year old presented to us with bilateral facial palsy due to herpes zoster oticus. Patient was having bilateral mild to moderate sensorineural hearing loss. Patient was treated with appropriate metabolic control, anti-inflammatory drugs and intravenous acyclovir. Due to uncontrolled diabetes, glucocorticoids were not used in this patient. Significant improvement in hearing status and facial nerve functions were seen in this patient. Conclusions Herpes zoster causes severe infections in diabetic patients and can be a cause of bilateral facial palsy and bilateral Ramsay Hunt syndrome. Herpes zoster in diabetic patients should be treated with appropriate metabolic control, NSAIDS and intravenous acyclovir, which we feel should be started at the earliest. Glucocorticoids should be avoided in diabetic patients. PMID:15575957

  20. Key comparison BIPM.RI(I)-K5 of the air-kerma standards of the SMU, Slovakia and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    The first direct comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0051 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the MKEH, Hungary and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Machula, G.

    2018-01-01

    A comparison of the standards for air kerma of the Hungarian Trade Licensing Office (MKEH), Hungary and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in March 2016. The comparison result, evaluated as a ratio of the MKEH and the BIPM standards for air kerma, is 1.0047 with a combined standard uncertainty of 1.9 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2.6 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Bilateral phacoemulsification in an orangutan (Pongo pygmaeus).

    PubMed

    Montiani-Ferreira, Fabiano; Lima, Leandro; Bacellar, Marianna; D'Otaviano Vilani, Ricardo G; Fedullo, José Daniel; Lange, Rogério R

    2010-09-01

    A 14-year-old, female, captive-born orangutan (Pongo pygmaeus) developed bilateral cataracts. Ultrasonography, electroretinography and cataract correction using phacoemulsification were performed bilaterally. This case report aims to describe the ophthalmic procedures performed in this animal critically endangered of extinction. The surgery successfully restored vision and normal activity to the patient.

  3. Sound-direction identification with bilateral cochlear implants.

    PubMed

    Neuman, Arlene C; Haravon, Anita; Sislian, Nicole; Waltzman, Susan B

    2007-02-01

    The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. Eight adults who were bilateral users of Nucleus 24 Contour devices participated in the study. All had received implants in both ears in a single surgery. Sound-direction identification was measured in a large classroom by using a nine-loudspeaker array. Localization was tested in three listening conditions (bilateral cochlear implants, left cochlear implant, and right cochlear implant), using two different stimuli (a speech stimulus and pink noise bursts) in a repeated-measures design. Sound-direction identification accuracy was significantly better when using two implants than when using a single implant. The mean root-mean-square error was 29 degrees for the bilateral condition, 54 degrees for the left cochlear implant, and 46.5 degrees for the right cochlear implant condition. Unilateral accuracy was similar for right cochlear implant and left cochlear implant performance. Sound-direction identification performance was similar for speech and pink noise stimuli. The data obtained in this study add to the growing body of evidence that sound-direction identification with bilateral cochlear implants is better than with a single implant. The similarity in localization performance obtained with the speech and pink noise supports the use of either stimulus for measuring sound-direction identification.

  4. Bilateral movements increase sustained extensor force in the paretic arm.

    PubMed

    Kang, Nyeonju; Cauraugh, James H

    2018-04-01

    Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.

  5. Coexistence of bilateral first and second branchial arch anomalies

    PubMed Central

    Thakur, J S; Shekar, Vidya; Saluja, Manika; Mohindroo, N K

    2013-01-01

    Branchial arch anomalies are one of the most common congenital anomalies that are usually unilateral and bilateral presentation is rare. The simultaneous presence of bilateral second branchial arch anomalies along with bilateral first arch anomalies is extremely rare, with only three such cases reported in the literature. We present two non-syndromic cases of coexisting bilateral first and second arch anomalies. Developmental anomalies of the branchial apparatus account for 17% of all paediatric cervical masses and are the most common type of congenital cervical mass. They usually present in the paediatric age group. About 96–97% of these anomalies are unilateral. Bilateral presentation is seen in 2–3% having a strong familial association. Congenital syndromes also have been associated with first and second branchial arch anomalies. Thorough clinical examination and investigations should be done to rule out these syndromes. PMID:23580675

  6. KEY COMPARISON: Final report on CCPR K1-a: Spectral irradiance from 250 nm to 2500 nm

    NASA Astrophysics Data System (ADS)

    Woolliams, Emma R.; Fox, Nigel P.; Cox, Maurice G.; Harris, Peter M.; Harrison, Neil J.

    2006-01-01

    The CCPR K1-a key comparison of spectral irradiance (from 250 nm to 2500 nm) was carried out to meet the requirements of the Mutual Recognition Arrangement by 13 participating national metrology institutes (NMIs). Because of the fragile nature of the tungsten halogen lamps used as comparison artefacts, the comparison was arranged as a star comparison with three lamps per participant. NPL (United Kingdom) piloted the comparison and, by measuring all lamps, provided a link between participants' measurements. The other participants were BNM-INM (France), CENAM (Mexico), CSIRO (Australia), HUT (Finland), IFA-CSIC (Spain), MSL-IRL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NRC (Canada), PTB (Germany) and VNIIOFI (Russian Federation). Before the analysis was completed and the results known, the pilot discussed with each participant which lamp measurements should be included as representative of their comparison. As a consequence of this check, at least one measurement was excluded from one third of the lamps because of changes due to transportations. The comparison thus highlighted the difficulty regarding the availability of suitable transfer standards for the dissemination of spectral irradiance. The use of multiple lamps and multiple measurements ensured sufficient redundancy that all participants were adequately represented. In addition, during this pre-draft A phase all participants had the opportunity to review the uncertainty budgets and methods of all other participants. This new process helped to ensure that all submitted results and their associated uncertainties were evaluated in a consistent manner. The comparison was analysed using a model-based method which regarded each lamp as having a stable spectral irradiance and the measurements made by an NMI as systematically influenced by a factor that applies to all that NMI's measurements. The aim of the analysis was to estimate the systematic factor for each NMI. Across the

  7. Key comparison BIPM.RI(I)-K5 of the air kerma standards of the ININ, Mexico and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D. T.; Alvarez Romero, J. T.; De la Cruz Hernández, D.; Cabrera Vertti, M. R.; Tovar-Muñoz, V. M.

    2015-01-01

    A direct comparison of the standards for air kerma of the Instituto Nacional de Investigaciones Nucleares (ININ), Mexico, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in February 2015. The comparison result, evaluated as a ratio of the ININ and the BIPM standards for air kerma, is 1.0048 with a combined standard uncertainty of 2.0 × 10-3. The results are analysed and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Bilateral silent sinus syndrome: A rare case and review of literature.

    PubMed

    Trope, Michal; Schwartz, Joseph S; Tajudeen, Bobby A; Kennedy, David W

    2017-06-01

    In this report, we presented a rare case of bilateral silent sinus syndrome (SSS) in an otherwise healthy 57-year-old man treated with functional endoscopic sinus surgery (FESS). A systematic review of the literature regarding bilateral SSS was performed. A 57-year-old man with well-controlled allergic rhinitis in the absence of previous surgery or trauma presented with bilateral SSS, which was successfully managed with bilateral FESS. A medical literature data base search of the terms "silent sinus syndrome" "maxillary atelectasis," "imploding antrum syndrome," and "bilateral silent sinus syndrome" was performed. The results were then narrowed to include only relevant articles. Relevant articles included three case reports and two articles that describe or mention bilateral SSS. Of the three case reports found, two patients presented with bilateral SSS, whereas the third patient presented metachronously, with the contralateral SSS manifesting 4 months after presentation of the initial ipsilateral SSS. The present literature regarding bilateral SSS is likely incomplete, and further investigation is required to provide greater insight into the prevalence of this disease. In this report, bilateral FESS was successful in resolving symptoms and preventing disease progression.

  9. A comparison of epidural buprenorphine plus detomidine with morphine plus detomidine in horses undergoing bilateral stifle arthroscopy.

    PubMed

    Fischer, Berit L; Ludders, John W; Asakawa, Makoto; Fortier, Lisa A; Fubini, Susan L; Nixon, Alan J; Radcliffe, Rolfe M; Erb, Hollis N

    2009-01-01

    To compare the analgesic efficacy of buprenorphine plus detomidine with that of morphine plus detomidine when administered epidurally in horses undergoing bilateral stifle arthroscopy. Prospective, randomized, blinded clinical trial. Twelve healthy adult horses participating in an orthopedic research study. Group M (n = 6) received morphine (0.2 mg kg(-1)) and detomidine (0.15 mg kg(-1)) epidurally; group B (n = 6) received buprenorphine (0.005 mg kg(-1)) and detomidine (0.15 mg kg(-1)) epidurally. Horses received one of two epidural treatments following induction of general anesthesia for bilateral stifle arthroscopy. Heart rate (HR), mean arterial blood pressure (MAP), end-tidal CO(2) (Pe'CO(2)), and end-tidal isoflurane concentrations (E'Iso%) were recorded every 15 minutes following epidural administration. Post-operative assessment was performed at 1, 2, 3, 6, 9, 12, and 24 hours after standing; variables recorded included HR, respiratory rate (f(R)), abdominal borborygmi, defecation, and the presence of undesirable side effects. At the same times post-operatively, each horse was videotaped at a walk and subsequently assigned a lameness score (0-4) by three ACVS diplomates blinded to treatment and who followed previously published guidelines. Nonparametric data were analyzed using Wilcoxon's rank-sum test. Inter- and intra-rater agreement were determined using weighted kappa coefficients. Statistical significance was set at p bilateral stifle arthroscopy, these doses of buprenorphine plus detomidine injected epidurally produced analgesia similar in intensity and

  10. Early assessment of bilateral inguinal hernia repair: A comparison between the laparoscopic total extraperitoneal and Stoppa approaches

    PubMed Central

    Utiyama, Edivaldo Massazo; Damous, Sérgio Henrique Bastos; Tanaka, Eduardo Yassushi; Yoo, Jin Hwan; de Miranda, Jocielle Santos; Ushinohama, Adriano Zuardi; Faro, Mario Paulo; Birolini, Claudio Augusto Vianna

    2016-01-01

    BACKGROUND: The present clinical trial was designed to compare the results of bilateral inguinal hernia repair between patients who underwent the conventional Stoppa technique and laparoscopic total extraperitoneal repair (LTE) with a single mesh and without staple fixation. PATIENTS AND METHODS: This controlled, randomised clinical trial was conducted at General Surgery and Trauma of the Clinics Hospital, Medical School, the University of São Paulo between September 2010 and February 2011. Totally, 50 male patients, with a bilateral inguinal hernia, older than 25 years were considered eligible for the study. The following parameters were analysed during the early post-operative period: (1) The intensity of surgical trauma, operation time, C-reactive protein (CRP) levels, white blood cell count, bleeding and pain intensity; (2) quality of life assessment; and (3) post-operative complications. RESULTS: LTE procedure was longer than the Stoppa procedure (134.6 min ± 38.3 vs. 90.6 min ± 41.3; P < 0.05). The levels of CRP were higher in the Stoppa group (P < 0.05) but the number of leucocytes, haematocrit, and haemoglobin were similar between the groups (P > 0.05). There was no difference in pain during the 1st and 7th post-operative, physical functioning, physical limitation, the impact of pain on daily activities, and the Carolinas Comfort Scale during the 7th and 15th post-operative (P > 0.05). Complications occurred in 88% of Stoppa group (22 patients) and 64% in LTE group (16 patients) (P < 0.05). CONCLUSION: The comparative study between the Stoppa and LTE approaches for the bilateral inguinal hernia repair demonstrated that: (1) The LTE approach showed less surgical trauma despite the longer operation time; (2) Quality of life during the early post-operative period were similar; and (3) Complication rates were higher in the Stoppa group. PMID:27279401

  11. Early assessment of bilateral inguinal hernia repair: A comparison between the laparoscopic total extraperitoneal and Stoppa approaches.

    PubMed

    Utiyama, Edivaldo Massazo; Damous, S Rgio Henrique Bastos; Tanaka, Eduardo Yassushi; Yoo, Jin Hwan; de Miranda, Jocielle Santos; Ushinohama, Adriano Zuardi; Faro, Mario Paulo; Birolini, Claudio Augusto Vianna

    2016-01-01

    The present clinical trial was designed to compare the results of bilateral inguinal hernia repair between patients who underwent the conventional Stoppa technique and laparoscopic total extraperitoneal repair (LTE) with a single mesh and without staple fixation. This controlled, randomised clinical trial was conducted at General Surgery and Trauma of the Clinics Hospital, Medical School, the University of São Paulo between September 2010 and February 2011. Totally, 50 male patients, with a bilateral inguinal hernia, older than 25 years were considered eligible for the study. The following parameters were analysed during the early post-operative period: (1) The intensity of surgical trauma, operation time, C-reactive protein (CRP) levels, white blood cell count, bleeding and pain intensity; (2) quality of life assessment; and (3) post-operative complications. LTE procedure was longer than the Stoppa procedure (134.6 min ± 38.3 vs. 90.6 min ± 41.3; P < 0.05). The levels of CRP were higher in the Stoppa group (P < 0.05) but the number of leucocytes, haematocrit, and haemoglobin were similar between the groups (P > 0.05). There was no difference in pain during the 1st and 7th post-operative, physical functioning, physical limitation, the impact of pain on daily activities, and the Carolinas Comfort Scale during the 7th and 15th post-operative (P > 0.05). Complications occurred in 88% of Stoppa group (22 patients) and 64% in LTE group (16 patients) (P < 0.05). The comparative study between the Stoppa and LTE approaches for the bilateral inguinal hernia repair demonstrated that: (1) The LTE approach showed less surgical trauma despite the longer operation time; (2) Quality of life during the early post-operative period were similar; and (3) Complication rates were higher in the Stoppa group.

  12. The phenotype of bilateral hippocampal sclerosis and its management in "real life" clinical settings.

    PubMed

    Sen, Arjune; Dugan, Patricia; Perucca, Piero; Costello, Daniel; Choi, Hyunmi; Bazil, Carl; Radtke, Rod; Andrade, Danielle; Depondt, Chantal; Heavin, Sinead; Adcock, Jane; Pickrell, W Owen; McGinty, Ronan; Nascimento, Fábio; Smith, Philip; Rees, Mark I; Kwan, Patrick; O'Brien, Terence J; Goldstein, David; Delanty, Norman

    2018-06-14

    There is little detailed phenotypic characterization of bilateral hippocampal sclerosis (HS). We therefore conducted a multicenter review of people with pharmacoresistant epilepsy and bilateral HS to better determine their clinical characteristics. Databases from 11 EPIGEN centers were searched. For identified cases, clinicians reviewed the medical notes, imaging, and electroencephalographic (EEG), video-EEG, and neuropsychometric data. Data were irretrievably anonymized, and a single database was populated to capture all phenotypic information. These data were compared with phenotyped cases of unilateral HS from the same centers. In total, 96 patients with pharmacoresistant epilepsy and bilateral HS were identified (43 female, 53 male; age range = 8-80 years). Twenty-five percent had experienced febrile convulsions, and 27% of patients had experienced status epilepticus. The mean number of previously tried antiepileptic drugs was 5.32, and the average number of currently prescribed medications was 2.99; 44.8% of patients had cognitive difficulties, and 47.9% had psychiatric comorbidity; 35.4% (34/96) of patients continued with long-term medical therapy alone, another 4 being seizure-free on medication. Sixteen patients proceeded to, or were awaiting, neurostimulation, and 11 underwent surgical resection. One patient was rendered seizure-free postresection, with an improvement in seizures for 3 other cases. By comparison, of 201 patients with unilateral HS, a significantly higher number (44.3%) had febrile convulsions and only 11.4% had experienced status epilepticus. Importantly, 41.8% (84/201) of patients with unilateral HS had focal aware seizures, whereas such seizures were less frequently observed in people with bilateral HS, and were never observed exclusively (P = .002; Fisher's exact test). The current work describes the phenotypic spectrum of people with pharmacoresistant epilepsy and bilateral HS, highlights salient clinical differences from patients

  13. Bilateral Vestibular Deficiency: Quality of Life and Economic Implications.

    PubMed

    Sun, Daniel Q; Ward, Bryan K; Semenov, Yevgeniy R; Carey, John P; Della Santina, Charles C

    2014-06-01

    Bilateral vestibular deficiency (BVD) causes chronic imbalance and unsteady vision and greatly increases the risk of falls; however, its effects on quality of life and economic impact are not well defined. To quantify disease-specific and health-related quality of life, health care utilization, and economic impact on individuals with BVD in comparison with those with unilateral vestibular deficiency (UVD). Cross-sectional survey study of patients with BVD or UVD and healthy controls at an academic medical center. Vestibular dysfunction was diagnosed by means of caloric nystagmography. Survey questionnaire. Health status was measured using the Dizziness Handicap Index (DHI) and Health Utility Index Mark 3 (HUI3). Economic burden was estimated using participant responses to questions on disease-specific health care utilization and lost productivity. Fifteen patients with BVD, 22 with UVD, and 23 healthy controls participated. In comparison with patients with UVD and controls, patients with BVD had significantly worse DHI (P < .001) and HUI3 scores. Statistically significant between-group differences were observed for overall HUI3 score (P < .001) and for specific attributes including vision, hearing, ambulation, emotion, and pain (P < .001 for all). Generalized linear model analysis of clinical variables associated with HUI3 scores after adjustment for other variables (including sex, race, education, age, and frequency of dizziness-related outpatient clinic visits) showed that the presence of UVD (P < .001) or BVD (P < .001), increased dizziness-related emergency room visits (P = .002), and increased dizziness-related missed work days (P < .001) were independently associated with worse HUI3 scores. Patients with BVD and UVD incurred estimated mean (range) annual economic burdens of $13,019 ($0-$48,830) and $3531 ($0-$48,442) per patient, respectively. Bilateral vestibular deficiency significantly decreases quality of life and imposes

  14. Bilateral varicocele: single transscrotal approach for Tauber antegrade sclerotherapy.

    PubMed

    Mazzoni, Guglielmo; Minucci, Sergio; Gentile, Vincenzo

    2003-03-01

    To describe the results of a new simple technique of single transscrotal approach for Tauber antegrade sclerotherapy in bilateral varicocele. During the period March 1998-June 2001, overall 341 patients were treated for varicocele using Tauber antegrade sclerotherapy. In 39 of these patients, sclerotherapy was performed bilaterally in the same session whilst in 34, rather than making two incisions at the root of the two hemiscrotums, a single incision was made on the median raphe. During this period, the same approach was used in 4 patients with left varicocele and right hydrocele, 2 patients with left varicocele and right epididymis cyst, 1 patient with bilateral varicocele and bilateral hydrocele, 1 patient with bilateral hydrocele and left varicocele. Maximum ray exposure time was 58 seconds (mean 30). Oro-tracheal intubation was not necessary in any of the patients. In 12 patients, besides local anesthesia, additional sedation was given. Slight bleeding of the wound, occurring in 3 patients, was medicated in the outpatient department. Patients prefer a single incision. When the incision is made on the median raphe, no scars remain. In bilateral varicocele, the single approach reduces invasiveness and increases patient satisfaction.

  15. Candidacy for bilateral hearing aids: a retrospective multicenter study.

    PubMed

    Boymans, Monique; Goverts, S Theo; Kramer, Sophia E; Festen, Joost M; Dreschler, Wouter A

    2009-02-01

    The goal of this study was to find factors for refining candidacy criteria for bilateral hearing aid fittings. Clinical files of 1,000 consecutive hearing aid fittings were analyzed. Case history, audiometric, and rehabilitation data were collected from clinical files, and an extensive questionnaire on long-term outcome measures was conducted. After at least 2 years of hearing aid use, 505 questionnaires were returned. In order to compare differences in benefits between unilateral and bilateral fittings, two subgroups were composed in which most relevant variables (age, degree of hearing loss, and audiometric asymmetry) were matched for unilateral fittings (n=212) and bilateral fittings (n=477). The bilateral group had significantly higher benefit scores than the unilateral group for detection, speech intelligibility in reverberation, and localization, but poorer scores for comfort of loud sounds. The benefit of bilateral hearing aids was not significantly related to the level of technology of the hearing aids. The analysis of the relation between objective parameters and the subjective outcome measures showed that candidacy for a successful bilateral fitting could not be predicted from age, maximum speech intelligibility, employment, exposure to background noise, or social activities.

  16. Sarcoidosis Presenting as Bilateral Vocal Fold Immobility.

    PubMed

    Hintze, Justin M; Gnagi, Sharon H; Lott, David G

    2018-05-01

    Bilateral true vocal fold paralysis is rarely attributable to inflammatory diseases. Sarcoidosis is a rare but important etiology of bilateral true vocal fold paralysis by compressive lymphadenopathy, granulomatous infiltration, and neural involvement. We describe the first reported case of sarcoidosis presenting as bilateral vocal fold immobility caused by direct fixation by granulomatous infiltration severe enough to necessitate tracheostomy insertion. In addition, we discuss the presentation, the pathophysiology, and the treatment of this disease with a review of the literature of previously reported cases of sarcoidosis-related vocal fold immobility. Sarcoidosis should therefore be an important consideration for the otolaryngologist's differential diagnosis of true vocal fold immobility. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  17. Unilateral Versus Bilateral Neck Exploration for Primary Hyperparathyroidism

    PubMed Central

    Bergenfelz, Anders; Lindblom, Pia; Tibblin, Sten; Westerdahl, Johan

    2002-01-01

    Objective To compare unilateral and bilateral neck exploration for primary hyperparathyroidism in a prospective randomized controlled trial. Summary Background Data Based on the assumption that unilateral neck exploration for a solitary parathyroid adenoma should reduce operating time and morbidity, a variety of minimally invasive procedures have challenged the idea that bilateral neck exploration is the gold standard for the surgical treatment of primary hyperparathyroidism. However, to date, no open prospective randomized trial has been published comparing unilateral and bilateral neck exploration. Methods Ninety-one patients with the preoperative diagnosis of primary hyperparathyroidism were randomized to unilateral or bilateral neck exploration. Preoperative scintigraphy and intraoperative parathyroid hormone measurement guided the unilateral exploration. Gross morphology and frozen section determined the extent of parathyroid tissue resection in the bilateral group. The primary end-point was the use of postoperative medication for hypocalcemic symptoms. Results Eighty-eight patients (97%) were cured. Histology and cure rate did not differ between the two groups. Patients in the bilateral group consumed more oral calcium, had lower serum calcium values on postoperative days 1 to 4, and had a higher incidence of early severe symptomatic hypocalcemia compared with patients in the unilateral group. In addition, for patients undergoing surgery for a solitary parathyroid adenoma, unilateral exploration was associated with a shorter operative time. The cost for the two procedures did not differ. Conclusions Patients undergoing a unilateral procedure had a lower incidence of biochemical and severe symptomatic hypocalcemia in the early postoperative period compared with patients undergoing bilateral exploration. Unilateral neck exploration with intraoperative parathyroid hormone assessment is a valid surgical strategy in patients with primary hyperparathyroidism with

  18. Characteristics of precision 1 Ω standard resistors influencing transport behaviour and the uncertainty of key comparisons

    NASA Astrophysics Data System (ADS)

    Jones, G. R.; Pritchard, B. J.; Elmquist, R. E.

    2009-10-01

    National measurement institutes (NMIs) participate in international key comparisons organized by the Bureau International des Poids et Mesures (BIPM), the Regional Metrology Organizations (RMOs) or the Consultative Committees of the Comité International des Poids et Mesures (CIPM) in order to provide evidence of equivalent reference standards and measurement capabilities. The US National Institute of Standards and Technology (NIST) and the National Measurement Institute of Australia (NMIA) have recently examined power loading and several other influences on the value of precision transportable 1 Ω resistors that can increase the uncertainty of key comparisons. We have studied the effects of temperature, barometric pressure, humidity, power loading and heat dissipation in oil on transportable wire-wound 1 Ω resistance standards that are based on different alloys and construction principles. This work focuses on standards manufactured from 1970 through 2000 by the NMIA made of Evanohm alloy and on Thomas-type resistors designed in the 1930s and made of Manganin alloy. We show that the relative standard uncertainty related to transport can be less than 0.01 μΩ Ω-1 when using certain resistors of these two types that are characterized and selected for stability. We describe the characterization process, and relate the environmental influences to the physical design, as well as to the mechanical properties and condition of the standards.

  19. Bilateral Patellar Tendon Rupture.

    PubMed

    Kamienski, Mary

    The knee is the most complex and largest joint in the body. Injuries to any part of this joint affect the entire body. There are multiple injuries that can occur to the knee, with the most common being ligament and meniscus tears. A not-so-common injury to the knee is a patellar tendon rupture. A bilateral patellar tendon rupture is extremely rare. A case study of a 43-year-old man who sustained a bilateral patellar tendon rupture while playing softball is used to present this devastating injury. This discussion includes the incidence and diagnosis of the tear, surgical repair, as well as a description of the comprehensive rehabilitation process necessary to allow the patient to return to normal physical activity. Risks and complications of this surgery and the expected outcomes are also presented.

  20. A Longitudinal Study in Children With Sequential Bilateral Cochlear Implants: Time Course for the Second Implanted Ear and Bilateral Performance.

    PubMed

    Reeder, Ruth M; Firszt, Jill B; Cadieux, Jamie H; Strube, Michael J

    2017-01-01

    Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization abilities. A prospective longitudinal study included 24 bilaterally implanted children (mean ear surgeries at 5.11 and 14.25 years). Test intervals were every 3-6 months through 24 months postbilateral. Test conditions were each ear and bilaterally for speech recognition and localization. Overall, the rate of progress for the second implanted ear was gradual. Improvements in quiet continued through the second year of bilateral use. Improvements in noise were more modest and leveled off during the second year. On all measures, results from the second ear were poorer than the first. Bilateral scores were better than either ear alone for all measures except sentences in quiet and localization. Older sequentially implanted children with several years between surgeries may obtain speech understanding in the second implanted ear; however, performance may be limited and rate of progress gradual. Continued contralateral ear hearing aid use and reduced time between surgeries may enhance outcomes.

  1. Cooled radiofrequency ablation for bilateral greater occipital neuralgia.

    PubMed

    Vu, Tiffany; Chhatre, Akhil

    2014-01-01

    This report describes a case of bilateral greater occipital neuralgia treated with cooled radiofrequency ablation. The case is considered in relation to a review of greater occipital neuralgia, continuous thermal and pulsed radiofrequency ablation, and current medical literature on cooled radiofrequency ablation. In this case, a 35-year-old female with a 2.5-year history of chronic suboccipital bilateral headaches, described as constant, burning, and pulsating pain that started at the suboccipital region and radiated into her vertex. She was diagnosed with bilateral greater occipital neuralgia. She underwent cooled radiofrequency ablation of bilateral greater occipital nerves with minimal side effects and 75% pain reduction. Cooled radiofrequency ablation of the greater occipital nerve in challenging cases is an alternative to pulsed and continuous RFA to alleviate pain with less side effects and potential for long-term efficacy.

  2. Cooled Radiofrequency Ablation for Bilateral Greater Occipital Neuralgia

    PubMed Central

    Chhatre, Akhil

    2014-01-01

    This report describes a case of bilateral greater occipital neuralgia treated with cooled radiofrequency ablation. The case is considered in relation to a review of greater occipital neuralgia, continuous thermal and pulsed radiofrequency ablation, and current medical literature on cooled radiofrequency ablation. In this case, a 35-year-old female with a 2.5-year history of chronic suboccipital bilateral headaches, described as constant, burning, and pulsating pain that started at the suboccipital region and radiated into her vertex. She was diagnosed with bilateral greater occipital neuralgia. She underwent cooled radiofrequency ablation of bilateral greater occipital nerves with minimal side effects and 75% pain reduction. Cooled radiofrequency ablation of the greater occipital nerve in challenging cases is an alternative to pulsed and continuous RFA to alleviate pain with less side effects and potential for long-term efficacy. PMID:24716017

  3. Bilateral guaifenesin ureteral calculi.

    PubMed

    Whelan, Chris; Schwartz, Bradley F

    2004-01-01

    We report on a patient with bilateral ureteral calculi composed of guaifenesin metabolite as determined by infrared spectroscopy. These stones may be associated with excessive guaifenesin intake related to the current popularity of ephedrine preparations.

  4. Laparoscopic repair of bilateral and recurrent hernias.

    PubMed

    Frankum, C E; Ramshaw, B J; White, J; Duncan, T D; Wilson, R A; Mason, E M; Lucas, G; Promes, J

    1999-09-01

    The optimal inguinal hernia repair has been controversial for decades. Since the advent of minimally invasive surgery, laparoscopic techniques have added to the controversy. Laparoscopic hernia repair has been advocated by many experts for the repair of bilateral and recurrent inguinal hernias. This study reviews the experience of a single community-based teaching hospital using the total extraperitoneal (TEP)-approach laparoscopic hernia repair for treating patients with bilateral and/or recurrent inguinal hernias. Since the TEP approach was adopted in June 1993, a total of 457 patients were treated for bilateral (322 patients) and/or recurrent (175) inguinal hernias (40 patients had recurrent and bilateral hernias). A total of 779 hernias were repaired with this technique. The average age of this patient group was 47 years, and there were 413 males and 44 females. Operative time averaged 68.3 minutes per patient, and there were 26 (5.7%) minor complications. There were 2 (0.4%) major complications, an enterotomy and a cystotomy, both early in the series and both in patients with previous lower abdominal surgery. There have been no deaths. With an average follow-up of 30 months (range, 1-60 months), there have been three (0.2%) recurrences. These recurrences were due to technical problems (inadequate mesh coverage), and each was repaired with a laparoscopic transabdominal approach or an anterior open approach. The use of the TEP-approach laparoscopic hernia repair is safe and effective in patients with recurrent and/or bilateral inguinal hernias.

  5. A Woman's Decision to Choose Bilateral Mastectomy.

    PubMed

    Jerome-D'Emilia, Bonnie; Suplee, Patricia D; Boiler, Jennifer L K; D'Emilia, John C

    2015-01-01

    Rates of bilateral mastectomy as treatment for unilateral breast cancer have been rising. Quantitative analyses have resulted in assumptions about why women choose this procedure, without confirmation from the women. The objective of this study was to explore a woman's decision making in the choice of bilateral mastectomy as a treatment for unilateral breast cancer, regardless of stage. A qualitative descriptive design was used. In-depth interviews were conducted by 2 researchers using a semistructured interview guide to elicit data, which were coded and analyzed using thematic analysis. Twenty-three women were interviewed. Five themes were identified that address specific determinants of the decision-making process: finding something, collecting evidence, perceived level of risk, identifying priorities, and making the decision. Nine women reported that their physicians recommended bilateral mastectomy. Women who recalled being advised of their risk of recurrence reported overestimates of that risk. The reasons women chose bilateral mastectomy were to avoid a lifetime of follow-up screenings with the subsequent fear of hearing that the breast cancer had returned and wanting to stay alive and well for their children and families. Except for women carrying genetic susceptibility to breast cancer, bilateral mastectomy is not considered the standard of care. Yet women are being offered or choosing this procedure. Nurses can be advocates for women by speaking positively about how women have the right to choose their treatment based on best evidence and personal choice. This evidence should include benefits and risks of the treatment.

  6. KEY COMPARISON: CCQM-K61: Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA

    NASA Astrophysics Data System (ADS)

    Woolford, Alison; Holden, Marcia; Salit, Marc; Burns, Malcolm; Ellison, Stephen L. R.

    2009-01-01

    Key comparison CCQM-K61 was performed to demonstrate and document the capability of interested national metrology institutes in the determination of the quantity of specific DNA target in an aqueous solution. The study provides support for the following measurement claim: "Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA". The comparison was an activity of the Bioanalysis Working Group (BAWG) of the Comité Consultatif pour la Quantité de Matière and was coordinated by NIST (Gaithersburg, USA) and LGC (Teddington, UK). The following laboratories (in alphabetical order) participated in this key comparison. DMSC (Thailand); IRMM (European Union); KRISS (Republic of Korea); LGC (UK); NIM (China); NIST (USA); NMIA (Australia); NMIJ (Japan); VNIIM (Russian Federation) Good agreement was observed between the reported results of all nine of the participants. Uncertainty estimates did not account fully for the dispersion of results even after allowance for possible inhomogeneity in calibration materials. Preliminary studies suggest that the effects of fluorescence threshold setting might contribute to the excess dispersion, and further study of this topic is suggested Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. On-site comparison of Quantum Hall Effect resistance standards of METAS and the BIPM: Ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Mortara, Alessandro; Jeanneret, Blaise

    2018-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Federal Institute of Metrology METAS (Switzerland) and of the Bureau International des Poids et Mesures (BIPM) was made in December 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 5 parts in 1010 with a relative combined standard uncertainty uc = 23 × 10‑10. Scaling from 100 Ω to 10 kΩ has also been addressed through the measurement of a 10000 Ω/100 Ω ratio. The measurements carried out agreed to 2 parts in 1010 with a relative combined standard uncertainty uc = 19 × 10‑10. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. ERP effects of spatial attention and display search with unilateral and bilateral stimulus displays.

    PubMed

    Lange, J J; Wijers, A A; Mulder, L J; Mulder, G

    1999-07-01

    Two experiments were performed in which the effects of selective spatial attention on the ERPs elicited by unilateral and bilateral stimulus arrays were compared. In Experiment 1, subjects received a series of grating patterns. In the unilateral condition these gratings were presented one at a time, randomly to the right or left of fixation. In the bilateral condition, gratings were presented in pairs, one to each side of fixation. In the unilateral condition standard ERP effects of visual spatial attention were observed. However, in the bilateral condition we failed to observe an attention related posterior contralateral positivity (overlapping the P1 and N1 components, latency interval about 100-250 ms), as reported in several previous studies. In Experiment 2, we investigated whether attention related ERP lateralizations are affected by the task requirement to search among multiple objects in the visual field. We employed a task paradigm identical to that used by Luck et al. (Luck, S.J., Heinze, H.J., Mangun, G.R., Hillyard, S.A., 1990. Visual event-related potentials index focused attention within bilateral stimulus arrays. II. Functional dissociation of P1 and N1 components. Electroencephalogr. Clin. Neurophysiol. 75, 528-542). Four letters were presented to a visual hemifield, simultaneously to both the attended and unattended hemifields in the bilateral conditions, and to one hemifield only in the unilateral conditions. In a focused attention condition, subjects searched for a target letter at a fixed position, whereas they searched for the target letter among all four letters in the divided attention condition (as in the experiment of Luck et al., 1990). In the bilateral focused attention condition, only the contralateral P1 was enhanced. In the bilateral divided attention condition a prolonged posterior positivity was observed over the hemisphere contralateral to the attended hemifield, comparable to the results of Luck et al. (1990). A comparison of the

  9. Final report on comparison of hydraulic pressure balance effective area determination in the range up to 80 MPa

    NASA Astrophysics Data System (ADS)

    Grgec Bermanec, L.; Pantic, D.; Ramac, B.

    2018-01-01

    Bilateral comparison was organized between the laboratory for process measurement of the Croatian Metrology Institute (HMI/FSB-LPM) and the pressure laboratory of the Directorate of Measures and Precious Metals of the Republic of Serbia (DMDM). Laboratory for process measurement of HMI acted as the pilot laboratory. The aim of the comparison was to evaluate the degree of equivalence in the determination of effective area and elastic distortion coefficient, considering respective uncertainties of the two laboratories. Measurements were done on the pressure balance in gauge mode, with oil as transmitting medium, in the gauge pressure range 10–80 MPa. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Using Evoked Potentials to Match Interaural Electrode Pairs with Bilateral Cochlear Implants

    PubMed Central

    Delgutte, Bertrand

    2007-01-01

    Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency–channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable. PMID:17225976

  11. Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants.

    PubMed

    Smith, Zachary M; Delgutte, Bertrand

    2007-03-01

    Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency-channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable.

  12. A case of bilateral vocal fold mucosal bridges, bilateral trans-vocal fold type III sulci vocales, and an intracordal polyp.

    PubMed

    Tan, Melin; Pitman, Michael J

    2011-07-01

    We present a patient with a novel finding of bilateral mucosal bridges, bilateral type III trans-vocal fold sulci vocales, and a vocal fold polyp. Although sulci and mucosal bridges occur in the vocal folds, it is rare to find multiples of these lesions in a single patient, and it is even more uncommon when they occur in conjunction with a vocal fold polyp. To our knowledge, this is the first description of a vocal fold polyp in combination with multiple vocal fold bridges and multiple type III sulci vocales in a single patient. To describe and visually present the diagnosis and treatment of a patient with an intracordal polyp, bilateral mucosal bridges, as well as bilateral type III trans-vocal fold sulci vocales. Presentation of a set of high definition intraoperative photos displaying the extent of the vocal fold lesions and the resection of the intracordal polyp. This patient presented with only 6 months of significant dysphonia. It was felt that the recent change in voice was because of the polyp and not the bridges or sulci vocales. Considering the patient's presentation and the possible morbidity of resection of mucosal bridges and sulci, only the polyp was excised. Postoperatively, the patient's voice returned to his acceptable mild baseline dysphonia, and the benefit has persisted 6 months postoperatively. The combination of bilateral mucosal bridges, bilateral type III sulcus vocalis, and an intracordal polyp in one patient is rare if not novel. Treatment of the polyp alone returned the patient's voice to his lifelong baseline of mild dysphonia. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  13. Fibrovascular tissue in bilateral juxtafoveal telangiectasis.

    PubMed

    Park, D; Schatz, H; McDonald, H R; Johnson, R N

    1996-09-01

    To study the natural history and retinal findings associated with the intraretinal and subretinal fibrovascular tissues that develop in the late phases of bilateral juxtafoveal telangiectasis. The records of 10 patients (11 eyes) with bilateral juxtafoveal telangiectasis who developed these fibrovascular tissues were examined. Throughout the follow-up period (average 44 months), only 2 eyes (18%) lost 2 or more lines of vision; the final visual acuities were similar for the eyes both with and without fibrovascular tissues. Sixty-four percent of fibrovascular tissues showed little to no growth. Eyes with fibrovascular tissue commonly had retinal pigment epithelial hyperplasia (72%), draining retinal venules (82%), and retinal vascular distortion (64%). Fibrovascular tissues of bilateral juxtafoveal telangiectasis have little proliferative potential and minimal effects on visual acuity. Nevertheless, these fibrovascular tissues do remodel over time, leading to retinal vascular distortion. Given these benign findings, the role of laser photocoagulation treatment of these tissues is questionable.

  14. Neuromarkers of Post-Traumatic Stress Disorder (PTSD) in a patient after bilateral hand amputation - ERP case study.

    PubMed

    Chrapusta, Anna; Kropotov, Juri D; Pąchalska, Maria

    2017-06-08

    Introduction. There is a lack in the worldwide literature of reports on the Neuromarkers of Post-Traumatic Stress Disorder (PTSD) in patients after bilateral hand amputation The aim of this study was to test a hypothesis regarding developing Post-Traumatic Stress Disorder (PTSD) in a patient after bilateral hand amputation with the use of Event Related Potentials (ERPs). On the basis of previous research, the amplitudes of P3 ERP components elicited in the cued GO/NOGO tasks have been chosen as candidates for neuromarkers of PTSD. Case study. A 24-year-old patient had undergone bilateral hand amputation 12 months previously. The patient was repeatedly operated on (he had undergone successful bilateral hand replantation) and despite the severity of the injuries, he recovered. However, the patient complained of flashbacks, anxiety and sleep difficulties. Specialist tests showed the presence of PTSD. The patient participated in the cued GO/NOGO task (Kropotov, 2009) with recording 19-channel EEG. P3 GO and NOGO waves in this task were found to be significantly smaller, in comparison to a group of healthy control subjects of the same age (N=23) taken from the HBI normative database (https://www.hbimed.com/). This observed pattern of ERP waves in the patient corresponds to the pattern found in PTSD patients. Conclusions. ERPs in a GO/NOGO task can be used in the assessment of the functional brain changes induced by chronic PTSD.

  15. Saline suppression test parameters may predict bilateral subtypes of primary aldosteronism.

    PubMed

    Hashimura, Hikaru; Shen, Jimmy; Fuller, Peter J; Chee, Nicholas Y N; Doery, James C G; Chong, Winston; Choy, Kay Weng; Gwini, Stella May; Yang, Jun

    2018-06-06

    The saline suppression test (SST) serves to confirm the diagnosis of primary aldosteronism (PA) while adrenal vein sampling (AVS) is used to determine whether the aldosterone hypersecretion is unilateral or bilateral. An accurate prediction of bilateral PA based on SST results could reduce the need for AVS. We sought to identify SST parameters that reliably predict bilateral PA. The results from 121 patients undergoing SSTs at Monash Health from January 2010 to January 2018 including screening blood tests, imaging, AVS and histopathology results were evaluated. Patients were subtyped into unilateral or bilateral PA based on AVS and surgical outcomes. Of 113 patients with confirmed PA, 33 had unilateral disease while 42 had bilateral disease. In those with bilateral disease, plasma aldosterone concentration (PAC) was significantly lower post-SST, together with a significant fall in the aldosterone-renin ratio (ARR). The combination of PAC <300 pmol/L and a reduction in ARR post-SST provided 96.8% specificity in predicting bilateral disease. Eighteen out of 39 patients (49%) with bilateral PA could have avoided AVS using these criteria. A combination of PAC <300 pmol/L and a lower ARR post-SST could reliably predict bilateral PA. An independent cohort will be needed to validate these findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  16. KEY COMPARISON: EUROMET.M.D-K4/EUROMET Project 702: Comparison of the calibrations of high-resolution hydrometers for liquid density determinations

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Malengo, A.; Vámossy, C.; Bettin, H.; Toth, H.; do Céu Ferreira, M.; Gosset, A.; Madec, T.; Heinonen, M.; Buchner, C.; Lenard, E.; Spurny, R.; Akcadag, U.; Domostroeva, N.

    2008-01-01

    The main objective of the EUROMET project 702 was to compare the extent of comparability among eleven participating European national metrology institutes (INRIM (IT), OMH (HU), PTB (DE), BEV (AT), IPQ (PT), LNE (FR), MIKES (FI), GUM (PL), SMU (SK), UME (TR) and VNIIM (RU)) in performing calibrations of high-resolution hydrometers for liquid density determination in the range between 600 kg m-3 and 1300 kg m-3. By means of two groups of four similar transfer standards of excellent metrological characteristics, the participating laboratories were initially divided into two groups (petals) linked by the three density laboratories of INRIM, OMH and PTB. The results of the participating laboratories have been analyzed in this report and a good agreement was found between the results provided by most of the participants. These results allowed also determination of the degrees of equivalence of each NMI participating with the EUROMET_key comparison reference values (EU_KCRV); they will provide a basis for the review of the Calibration Measurement Capabilities (CMC) entries on hydrometer calibration, and they allowed the degree of equivalence between pairs of NMIs to be established. The Istitituto Nazionale di Ricerca Metrologica (INRIM), Italy, formerly IMGC-CNR, coordinated the project. Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Key comparison study on peptide purity—synthetic human C-peptide

    NASA Astrophysics Data System (ADS)

    Josephs, R. D.; Li, M.; Song, D.; Westwood, S.; Stoppacher, N.; Daireaux, A.; Choteau, T.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Flatschart, R.; Borges Oliveira, R.; Melanson, J. E.; Ohlendorf, R.; Henrion, A.; Kinumi, T.; Wong, L.; Liu, Q.; Oztug Senal, M.; Vatansever, B.; Ün, I.; Gören, A. C.; Akgöz, M.; Quaglia, M.; Warren, J.

    2017-01-01

    Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115, was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM). Eight Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of human C-peptide (hCP) present as the main component in the comparison sample for CCQM-K115. The comparison samples were prepared from synthetic human hCP purchased from a commercial supplier and used as provided without further treatment or purification. hCP was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of short (up to 5 kDa), non-cross-linked synthetic peptides/proteins. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used a peptide impurity corrected amino acid analysis (PICAA) approach as the amount of material that has been provided to each participant (25 mg) is insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, both the BIPM and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the hCP mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the hCP purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the hCP mass fraction. In particular it allows participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification

  18. Unilateral and Mild Bilateral Hearing Loss in Children: Past and Current Perspectives

    PubMed Central

    Tharpe, Anne Marie

    2008-01-01

    Since the early 1980s, audiologists have become increasingly aware of the potential effect of even mild degrees of hearing loss on the psychoeducational and psychosocial outcomes of children. This review describes some of the key research findings during the past several decades that have led us to our current thinking about unilateral and mild bilateral hearing loss in children. The first section addresses unilateral hearing loss. This is followed by a review of the literature on mild bilateral hearing loss. Specifically, the issues addressed include the significance of permanent mild degrees of hearing loss on children's psychoeducational and psychosocial development and the speech, language, and auditory characteristics of children with mild degrees of hearing loss. Finally, some recommendations regarding the direction of future research are offered. This review is followed by 2 articles summarizing the proceedings of a 2005 workshop convened by the Centers for Disease Control and Prevention (CDC), Early Hearing Detection and Intervention (EHDI) program, and the Marion Downs Hearing Center to address concerns about the underidentification of—and professionals' apparent lack of awareness of—permanent unilateral and minimal to mild hearing loss in children.56,57 PMID:18270174

  19. Bilateral nanophthalmos and pigmentary retinal dystrophy--an unusual syndrome.

    PubMed

    Proença, Helena; Castanheira-Dinis, A; Monteiro-Grillo, M

    2006-09-01

    To report the clinical picture of the rare association of nanophthalmos and pigmentary retinal dystrophy and its cataract surgery outcome. We report a case of a 60-year-old female who presented with bilateral slowly progressive visual loss. The patient presented with bilateral light perception visual acuity, exotropia, brunescent cataract hindering fundus examination and hypodontia. Ultrasonography revealed bilateral nanophthalmos. A visual-evoked potential was also performed preoperatively. Cataract surgery with +40D IOL implantation was uneventful. Postoperative fundus examination revealed pigmentary retinal dystrophy, confirmed by electrophysiologic tests. Glycosaminoglycan urinary excretion was normal. Congenital bilateral nanophthalmos may rarely be associated with pigmentary retinal dystrophy. We suggest thorough preoperative evaluation in nanophthalmic eyes for the exclusion of significant features concerning visual prognosis.

  20. Bilateral patellar tuberculosis masquerading as infected infrapatellar bursitis.

    PubMed

    Sreenivasan, Ravi; Haq, Rehan Ul

    2017-04-01

    A 30-year-old woman presented to our outpatient department with complaints of pain and swelling in bilateral infrapatellar regions and a discharging sinus in the right knee over the duration of one year. Radiographs showed lytic regions in bilateral patellae. Samples sent from material curetted from sinus yielded no organism but histopathology reported granulomatous inflammation. Following a fresh magnetic resonance imaging (MRI) scan that revealed the infrapatellar pad of fat communicating with the patellar lesions, an exploration and evacuation was done. Material sent revealed epithelioid cell granulomas with caseous necrosis consistent with tuberculosis (TB). The patient was put on first line anti-tubercular treatment (ATT) and has responded favourably with healing of sinus and patellar lesions. Bilateral infrapatellar bursitis is not rare. However patellar TB as a cause for OMIT is not a common diagnosis. A bilateral patellar involvement has not been reported in literature to the best of our knowledge.

  1. Synchronous Bilateral Male Breast Cancer: A Case Report

    PubMed Central

    Sun, Woo-Young; Lee, Ki-Hyeong; Lee, Ho-Chang; Ryu, Dong-Hee; Park, Jin-Woo; Yun, Hyo-Young

    2012-01-01

    Synchronous bilateral breast cancer is extremely rare in men and has not, up to date, been reported in Korea. A 54-year-old man presented with a palpable mass in the right breast. The right nipple was retracted and bilateral axillary accessory breasts and nipples were present. On physical examination, a 2 cm-sized mass was palpated directly under the right nipple, and, with squeezing, bloody discharge developed in a single duct of the left nipple. There was no palpable mass in the left breast, and axillary lymph nodes were not palpable. Physical examination of external genitalia revealed a unilateral undescended testis on the left side. Synchronous bilateral breast cancer was diagnosed using mammography, ultrasonography, and core-needle biopsy. Histopathological examination revealed invasive ductal carcinoma in the right breast and ductal carcinoma in situ in the left breast. Bilateral total mastectomy, sentinel lymph node biopsy, and excision of accessory breasts in the axilla were performed. PMID:22807945

  2. Synchronous bilateral male breast cancer: a case report.

    PubMed

    Sun, Woo-Young; Lee, Ki-Hyeong; Lee, Ho-Chang; Ryu, Dong-Hee; Park, Jin-Woo; Yun, Hyo-Young; Song, Young-Jin

    2012-06-01

    Synchronous bilateral breast cancer is extremely rare in men and has not, up to date, been reported in Korea. A 54-year-old man presented with a palpable mass in the right breast. The right nipple was retracted and bilateral axillary accessory breasts and nipples were present. On physical examination, a 2 cm-sized mass was palpated directly under the right nipple, and, with squeezing, bloody discharge developed in a single duct of the left nipple. There was no palpable mass in the left breast, and axillary lymph nodes were not palpable. Physical examination of external genitalia revealed a unilateral undescended testis on the left side. Synchronous bilateral breast cancer was diagnosed using mammography, ultrasonography, and core-needle biopsy. Histopathological examination revealed invasive ductal carcinoma in the right breast and ductal carcinoma in situ in the left breast. Bilateral total mastectomy, sentinel lymph node biopsy, and excision of accessory breasts in the axilla were performed.

  3. Frontoethmoidal mucocele associated with bilateral increased intraocular pressure and proptosis.

    PubMed

    Chandra, Aman; Lim, Mingyann; Scott, Elizabeth; Morsman, David

    2007-02-01

    We describe the case of a 53-year-old man presenting with bilateral proptosis and raised intraocular pressure. Computed tomography imaging revealed these signs to be secondary to a frontoethmoidal mucocele with bilateral orbital invasion. Bilateral increased intraocular pressure is unusual in cases of frontoethmoidal mucoceles, but prompt imaging and treatment can prevent permanent visual loss.

  4. Mesh Displacement After Bilateral Inguinal Hernia Repair With No Fixation

    PubMed Central

    Rocha, Gabriela Moreira; Campos, Antonio Carlos Ligocki; Paulin, João Augusto Nocera; Coelho, Julio Cesar Uili

    2017-01-01

    Background and Objectives: About 20% of patients with inguinal hernia present bilateral hernias in the diagnosis. In these cases, laparoscopic procedure is considered gold standard approach. Mesh fixation is considered important step toward avoiding recurrence. However, because of cost and risk of pain, real need for mesh fixation has been debated. For bilateral inguinal hernias, there are few specific data about non fixation and mesh displacement. We assessed mesh movement in patients who had undergone laparoscopic bilateral inguinal hernia repair without mesh fixation and compared the results with those obtained in patients with unilateral hernia. Methods: From January 2012 through May 2014, 20 consecutive patients with bilateral inguinal hernia underwent TEP repair with no mesh fixation. Results were compared with 50 consecutive patients with unilateral inguinal hernia surgically repaired with similar technique. Mesh was marked with 3 clips. Mesh movements were measured by comparing initial radiography performed at the end of surgery, with a second radiographic scan performed 30 days later. Results: Mean movements of all 3 clips in bilateral nonfixation (NF) group were 0.15–0.4 cm compared with 0.1–0.3 cm in unilateral NF group. Overall displacement of bilateral and unilateral NF groups did not show significant difference. Mean overall displacement was 1.9 cm versus 1.8 cm in the bilateral and unilateral NF groups, respectively (P = .78). Conclusions: TEP with no mesh fixation is safe in bilateral inguinal repairs. Early mesh displacement is minimal. This technique can be safely used in most patients with inguinal hernia. PMID:28904521

  5. Bilateral cerebral hemispheric infarction associated with sildenafil citrate (Viagra) use.

    PubMed

    Kim, K-K; Kim, D G; Ku, Y H; Lee, Y J; Kim, W-C; Kim, O J; Kim, H S

    2008-03-01

    Sildenafil citrate (Viagra) is one of the frequently prescribed drugs for men with erectile dysfunction. We describe a 52-year-old man with bilateral middle cerebral artery (MCA) territory infarction after sildenafil use. He ingested 100 mg of sildenafil and about 1 h later, he complained of chest discomfort, palpitation and dizziness followed by mental obtundation, global aphasia and left hemiparesis. Brain magnetic resonance imaging documented acute bilateral hemispheric infarction, and cerebral angiography showed occluded bilateral MCA. Despite significant bilateral MCA stenosis and cerebral infarction, systemic hypotension persisted for a day. We presume that cerebral infarction was caused by cardioembolism with sildenafil use.

  6. Intermittent bilateral coherence in physiological and essential hand tremor.

    PubMed

    Chakraborty, Soma; Kopecká, Jana; Šprdlík, Otakar; Hoskovcová, Martina; Ulmanová, Olga; Růžička, Evžen; Zapotocky, Martin

    2017-04-01

    To investigate the prevalence and the temporal structure of bilateral coherence in physiological (PT) and essential (ET) hand tremor. Triaxial accelerometric recordings from both hands in 30 healthy subjects and 34 ET patients were analyzed using spectral coherence and wavelet coherence methods. In 12 additional healthy subjects, the relation between the hand tremor and the chest wall acceleration was evaluated using partial coherence analysis. The majority of both PT and ET subjects displayed significant bilateral coherence. While in PT, bilateral coherence was most frequently found in resting hand position (97% of subjects), in ET the prevalence was comparable for resting (54%) and postural (49%-57%) positions. In both PT and ET, epochs of strong coherence lasting several to a dozen seconds were separated by intervals of insignificant coherence. In PT, bilateral coherence at the main tremor frequency (8-12Hz) was coupled with the ballistocardiac rhythm. The oscillations of the two hands are intermittently synchronized in both PT and ET. We propose that in postural PT, bilateral coherence at the main tremor frequency arises from transient simultaneous entrainment of the left and right hand oscillations to ballistocardiac forcing. Bilateral coherence of hand kinematics provides a sensitive measure of synchronizing influences on the left and right tremor oscillators. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  7. Functional outcomes of simultaneous bilateral versus unilateral total knee arthroplasty.

    PubMed

    Bagsby, Deren; Pierson, Jeffery L

    2015-01-01

    Many patients in need of total knee arthroplasty (TKA) have bilateral symptoms and require surgery to both extremities. Performance of a bilateral procedure under a single anesthetic provides a reduced hospitalization time, an isolated anesthesia risk, a single rehabilitation, and substantial cost savings. While most current research examines postoperative complication rates, the primary purpose of TKA is the alleviation of pain and improved quality of life. The purpose of this study was to assess pain and functional outcomes associated with simultaneous bilateral TKA. The authors believe that patients with advanced destructive arthritis to numerous joints cannot achieve complete restoration of their functional status until comprehensive treatment of their disease process occurs. A retrospective review of 697 TKAs in 511 consecutive patients with bilateral knee arthritis was performed. Patients underwent either simultaneous bilateral TKA (n=186), performed sequentially under the same anesthetic, or unilateral TKA (n=325). The same intra- and postoperative protocols were followed in each group. There was no statistically significant difference in postoperative pain, represented by Knee Society Score (P=.161). However, there was a significantly higher postoperative functional outcomes-including increased total range of motion (P=.001), flexion (P=.003), and function score (P<.001)-associated with bilateral TKA. Simultaneous bilateral TKA is an effective treatment option and may be worth possible added risk in appropriate patients because it produces a better functional outcome. Copyright 2015, SLACK Incorporated.

  8. Final report of the key comparison CCQM-K106: Pb, As and Hg measurements in cosmetic (cream)

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Wang, Qian; Yamani, Randa Nasr Ahmed; Shehata, Adel B.; Jacimovic, Radojko; Pavlin, Majda; Horvat, Milena; Tsoi, Y. P.; Tsang, C. K.; Shin, Richard; Chailap, Benjamat; Yafa, Charun; Caciano de Sena, Rodrigo; de Almeida, Marcelo; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Heun Kim, Sook; Konopelko, Leonid; Ari, Betül; Tokman, Nilgün; Rienitz, Olaf; Jaehrling, Reinhard; Pape, Carola

    2015-01-01

    Cosmetics are used in practically all walks of life as a means of improving skin and beautifying complexion. In recent years, more and more attention has been paid to the cosmetic safety. In response to the cosmetic safety issue, the accurate measurement of the heavy metals in cosmetics is, therefore, particularly important. NMIs from different countries should establish their chemical metrology traceability system in this area, which includes both measurement methods research and certain CRMs development. It should be noted that because the matrix of many cosmetics is complex and the contents of the heavy metals are relatively low, it still is a challenging task to measure the analytes with high accuracy and precision. CCQM-K106 followed up CCQM pilot study 'CCQM-P128: Pb, As measurements in cosmetic (cream)' coordinated by the National Institute of Metrology, China (NIM) in 2009. The cream was selected as the testing material, which is widely used as a daily skin care worldwide. This is the first CCQM key comparison regarding the measurement of toxic metal elements with the cosmetic matrix, which includes pure water, liquid paraffin, silicone oil, synthetic squalane, hyaluronic acid, glycerin, propylene glycol, allantoin, preservative and so on. The aim of the CCQM-K106 is to demonstrate the capability of participating NMIs and designated institutes in measuring the contents of poisonous elements, including lead, arsenic and mercury in a cosmetic sample (cream), and support CMC claims relating to inorganic elements in cosmetic materials and similar chemical industry products. The cream matrix sample was prepared under the guidance of professional technicians. The formula of the cream was carefully chosen to match with a real cosmetic. The homogeneity and stability level of Pb, As and Hg in the cream sample were fit for the objective of the comparison. Each participant received two numbered bottles containing about 5g samples in each bottle. The instruction

  9. Bilateral Herpes Simplex Uveitis: Review of the Literature and Own Reports‏.

    PubMed

    de-la-Torre, Alejandra; Valdes-Camacho, Juanita; Foster, C Stephen

    2017-08-01

    Herpes simplex-associated uveitis is usually considered a unilateral eye disease, and rarely included in the differential diagnosis whenever there is bilateral involvement. We report three cases of bilateral herpetic anterior uveitis. We evaluated three patients who presented with clinical manifestations of bilateral uveitis suggestive of viral origin. We found intraocular hypertension, cells in the anterior chamber, paralytic mydriasis, iris atrophy with transillumination defects, and variable anterior vitreous cellularity. According to the clinical findings, supported with herpes-specific antibody titers and aqueous humor PCR results in two of them, they were diagnosed with bilateral anterior herpetic uveitis. Our patients were initially misdiagnosed as having non-infectious uveitis and were treated with immunomodulatory medications, which could have favored the extension of infection bilaterally. Although uncommon, bilateral herpetic uveitis should always be considered in the differential diagnoses, when patients present with hypertensive uveitis in both eyes.

  10. Subxiphoid uniportal video-assisted thoracoscopic surgery for synchronous bilateral lung resection.

    PubMed

    Yang, Xueying; Wang, Linlin

    2018-01-01

    With advancements in medical imaging and current emphasis on regular physical examinations, multiple pulmonary lesions increasingly are being detected, including bilateral pulmonary lesions. Video-assisted thoracic surgery is an important method for treating such lesions. Most of video-assisted thoracic surgeries for bilateral pulmonary lesions were two separate operations. Herein, we report a novel technique of synchronous subxiphoid uniportal video-assisted thoracic surgery for bilateral pulmonary lesions. Synchronous bilateral lung resection procedures were performed through a single incision (~4 cm, subxiphoid). This technique was used successfully in 11 patients with bilateral pulmonary lesions. There were no intraoperative deaths or mortality recorded at 30 days. Our results show that the subxiphoid uniportal thoracoscopic procedure is a safe and feasible surgical procedure for synchronous bilateral lung resection with less surgical trauma, postoperative pain and better cosmetic results in qualifying patients. Further analysis is ongoing, involving a larger number of subjects.

  11. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the IST-LPSR, Portugal and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Cardoso, J.

    2018-01-01

    A comparison of the standards for air kerma of the Instituto Superior Técnico, Laboratório de Proteção e Segurança Radiológica (IST-LPSR), Portugal and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in December 2015. The comparison result, evaluated as a ratio of the IST-LPSR and the BIPM standards for air kerma, is 1.0026 with a combined standard uncertainty of 1.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 1.1 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral acoustic neuromas.

    PubMed

    Anand, V T; Byrnes, D P; Walby, A P; Kerr, A G

    1993-10-01

    This article reviews 12 patients with bilateral acoustic neuromas. The sex incidence was equal and the mean age at diagnosis was 26.2 years. The family history was positive in nine of the patients. Five patients have had incomplete surgical removal of acoustic neuromas on both sides. Two of them are completely deaf and the other three have severe sensorineural hearing loss in one ear and no hearing in the other ear. In five patients the tumour on one side has been operated on and the other side is being observed with at least short-term preservation of good hearing. The remaining two patients died of intra-cranial complications, one of them post-operatively. Four patients developed facial palsy immediately following surgery and one developed facial weakness 6 months after surgery. Guidelines are discussed for the care of these patients including the timing of surgery and alternative treatment options (observation, radio-surgery and chemotherapy). This is essentially a group of young individuals who have had multiple operations for bilateral acoustic tumours and associated manifestations and for whom the disease and the sequelae of treatment can be tragic.

  13. Rigorously defined hemicrania continua presenting bilaterally.

    PubMed

    Southerland, Andrew M; Login, Ivan S

    2011-10-01

    Hemicrania continua (HC) is a headache syndrome characterized by continuous, unilateral head pain, autonomic features, and a complete therapeutic response to indomethacin. Although HC is classified as a unique entity among primary headache disorders, it clearly shares features with other primary headaches, including trigeminal autonomic cephalalgias, and chronic daily headaches, such as chronic migraine and chronic tension-type headache. In addition, the diagnosis is often delayed secondary to a relatively low incidence and the occurrence of some phenotypic variability as found in previous case series. A 62-year-old woman presented with 5 months of unremitting, bilateral headache with significant autonomic symptoms during exacerbations of pain. Neurological examination and imaging studies were normal. After failure to respond to numerous previous therapeutic medicines and interventions, she experienced complete resolution following administration of indomethacin and eventual remission on sustained treatment. This case demonstrates that hemicrania continua with requisite autonomic features can occur in a purely bilateral form. Although the definitive aspects of HC continue to evolve, a bilateral headache meeting the current criteria warrants a therapeutic trial of indomethacin.

  14. Bilateral parietal contributions to spatial language.

    PubMed

    Conder, Julie; Fridriksson, Julius; Baylis, Gordon C; Smith, Cameron M; Boiteau, Timothy W; Almor, Amit

    2017-01-01

    It is commonly held that language is largely lateralized to the left hemisphere in most individuals, whereas spatial processing is associated with right hemisphere regions. In recent years, a number of neuroimaging studies have yielded conflicting results regarding the role of language and spatial processing areas in processing language about space (e.g., Carpenter, Just, Keller, Eddy, & Thulborn, 1999; Damasio et al., 2001). In the present study, we used sparse scanning event-related functional magnetic resonance imaging (fMRI) to investigate the neural correlates of spatial language, that is; language used to communicate the spatial relationship of one object to another. During scanning, participants listened to sentences about object relationships that were either spatial or non-spatial in nature (color or size relationships). Sentences describing spatial relationships elicited more activation in the superior parietal lobule and precuneus bilaterally in comparison to sentences describing size or color relationships. Activation of the precuneus suggests that spatial sentences elicit spatial-mental imagery, while the activation of the SPL suggests sentences containing spatial language involve integration of two distinct sets of information - linguistic and spatial. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. CUDA-based acceleration and BPN-assisted automation of bilateral filtering for brain MR image restoration.

    PubMed

    Chang, Herng-Hua; Chang, Yu-Ning

    2017-04-01

    relative error in terms of peak signal-to-noise ratio (PSNR) less than 0.1%. In comparison with many state-of-the-art filters, the proposed automation framework with CUDA-based bilateral filtering provided more favorable results both quantitatively and qualitatively. Possessing unique characteristics and demonstrating exceptional performances, the proposed CUDA-based bilateral filter adequately removed random noise in multifarious brain MR images for further study in neurosciences and radiological sciences. It requires no prior knowledge of the noise variance and automatically restores MR images while preserving fine details. The strategy of exploiting the CUDA to accelerate the computation and incorporating texture features into the BPN to completely automate the bilateral filtering process is achievable and validated, from which the best performance is reached. © 2017 American Association of Physicists in Medicine.

  16. Bilateral gas gangrene of the hand - a unique case.

    PubMed Central

    Goyal, R. W.; Ng, A. B. Y.; Bale, R. S.

    2003-01-01

    Gas gangrene is a rare and rapidly progressive process with the propensity for devastating consequences. We report the first case of bilateral gas gangrene of the hand following bilateral middle phalangectomy of the middle fingers. PMID:14629884

  17. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    PubMed

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI

  18. Rayleigh-maximum-likelihood bilateral filter for ultrasound image enhancement.

    PubMed

    Li, Haiyan; Wu, Jun; Miao, Aimin; Yu, Pengfei; Chen, Jianhua; Zhang, Yufeng

    2017-04-17

    Ultrasound imaging plays an important role in computer diagnosis since it is non-invasive and cost-effective. However, ultrasound images are inevitably contaminated by noise and speckle during acquisition. Noise and speckle directly impact the physician to interpret the images and decrease the accuracy in clinical diagnosis. Denoising method is an important component to enhance the quality of ultrasound images; however, several limitations discourage the results because current denoising methods can remove noise while ignoring the statistical characteristics of speckle and thus undermining the effectiveness of despeckling, or vice versa. In addition, most existing algorithms do not identify noise, speckle or edge before removing noise or speckle, and thus they reduce noise and speckle while blurring edge details. Therefore, it is a challenging issue for the traditional methods to effectively remove noise and speckle in ultrasound images while preserving edge details. To overcome the above-mentioned limitations, a novel method, called Rayleigh-maximum-likelihood switching bilateral filter (RSBF) is proposed to enhance ultrasound images by two steps: noise, speckle and edge detection followed by filtering. Firstly, a sorted quadrant median vector scheme is utilized to calculate the reference median in a filtering window in comparison with the central pixel to classify the target pixel as noise, speckle or noise-free. Subsequently, the noise is removed by a bilateral filter and the speckle is suppressed by a Rayleigh-maximum-likelihood filter while the noise-free pixels are kept unchanged. To quantitatively evaluate the performance of the proposed method, synthetic ultrasound images contaminated by speckle are simulated by using the speckle model that is subjected to Rayleigh distribution. Thereafter, the corrupted synthetic images are generated by the original image multiplied with the Rayleigh distributed speckle of various signal to noise ratio (SNR) levels and

  19. Bilateral same-day endoscopic transcanal cartilage tympanoplasty: initial results.

    PubMed

    Daneshi, Ahmad; Jahandideh, Hesam; Daneshvar, Ali; Safdarian, Mahdi

    Same-day closure of bilateral tympanic membrane perforations is a quick and more comfortable procedure for the patients. However, conventional bilateral same-day tympanoplasty or myringoplasty has been rarely performed because of the theoretical risk of postoperative complications. To evaluate the advantages and outcomes of bilateral simultaneous endoscopic cartilage tympanoplasty in patients with bilateral tympanic membrane perforations. From February 2012 to March 2013, patients with bilateral dry tympanic membrane perforations who had some degree of hearing loss corresponding to the size and location of the perforation entered the study. There was no suspicion to disrupted ossicular chain, mastoid involvement or other middle or inner ear pathology. Endoscopic transcanal cartilage tympanoplasty was done using the underlay (medial) technique. The graft was harvested from cymba cartilage in just one ear with preservation of perichondrium in one side. A 1.5cm×1.5cm cartilage seemed to be enough for tympanoplasty in both sides. Nine patients (4 males and 5 females) with the mean age of 37.9 years underwent bilateral transcanal cartilage tympanoplasty in a same-day surgery. The mean duration of follow up was 15.8 months. There were detected no complications including hearing loss, otorrhea and wound complication with no retraction pocket or displaced graft during follow-up period. The grafts take rate was 94.44% (only one case of unilateral incomplete closure). The mean of air-bone gap overall improved from 13.88dB preoperatively to 9.16dB postoperatively (p<0.05). Bilateral endoscopic transcanal cartilage tympanoplasty can be considered as a safe minimally invasive procedure that can be performed in a same-day surgery. It reduces the costs and operation time and is practical with a low rate of postoperative complications. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights

  20. Laparoscopic bilateral simultaneous adrenalectomy: results of 11 operations.

    PubMed

    Pugliese, Raffaele; Boniardi, Marco; de Carli, Stefano; Sansonna, Fabio; Costanzi, Andrea; Maggioni, Dario; Ferrari, Giovanni C; Di Lernia, Stefano; Loli, Paola; Grossrubatscher, Erika

    2008-08-01

    This study was undertaken to evaluate the outcomes of the simultaneous bilateral laparoscopic adrenalectomy. This was a retrospective study, including 11 patients with bilateral adrenal lesions, affected by Cushing's syndrome (n=2), Cushing's disease (n=6), pheochromocytoma (n=2), and 1 adrenocorticotrophin-hormone-dependent hypercortisolism of unknown origin. Elevan bilateral adrenalectomies were carried out by the laparoscopic approach with no conversions. The operations were performed in 7 cases by the lateral transperitoneal adrenalectomy (LTLA), in 3 by the posterior approach (PRA), and in 1 by the combined approach. The mean size of the masses was 5 cm. (range, 4-13). The average operating time was 245 minutes for LTLA and 218 minutes for PRA (P<0.05). The estimated mean blood loss was 87+/-36 mL (range, 20-150). No patients required transfusions. The mean hospital stay was 5+/-1.8 days (range, 4-7). The mean follow-up was 34 months (range, 2-96). Our study confirms that the bilateral adrenalectomy by the minimally invasive technique is safe and effective, affording acceptable blood loss and morbidity with a short hospital stay.

  1. Management of bilateral patellar luxation in an alpaca.

    PubMed

    Abuja, Gustavo A; Kowaleski, Michael P; García-López, José M

    2014-05-01

    To report surgical management bilateral lateral patellar luxation in a mature alpaca using a combination of trochlear wedge recession (TWR), tibial tuberosity transposition (TTT), and joint capsule imbrication. Clinical case report. 9-year-old castrated male Alpaca. Bilateral, grade III/IV, lateral patellar luxation was identified by palpation, lameness examination and confirmed with radiography and ultrasonography. Surgical procedures were staged, with the left stifle treated first. Bilateral TWR, TTT, and joint capsule imbrication were performed. Outcome was assessed by radiography and follow up lameness examinations. An immediate improvement in weight bearing occurred after surgery of the left hind limb. Five months after initial surgery, right hind limb patella luxation was corrected. After surgery on the 2nd limb, the alpaca had progressive improvement in weight bearing during hospitalization. At 12 months, there were no signs of lameness and the alpaca had resumed normal activities. For bilateral lateral patellar luxation, a combination of TWR, TTT, and joint capsule imbrication resulted in excellent long-term outcome. © Copyright 2014 by The American College of Veterinary Surgeons.

  2. Bilateral panuveitis associated with Whipple disease - case report.

    PubMed

    Lisboa, Maria; Domingues, Isabel; Pamplona, Jaime; Barata, Pedro; Morgado, Joana; Brotas, Vítor

    2014-01-01

    To describe a clinical case and literature review of Whipple disease. A 65-year-old male with bilateral decreased visual acuity for 3 weeks as well as bilateral hypoacusia, vertigo, disequilibrium, headache and decreased strength in the right upper limb for 4 months. The clinical work-up revealed a bilateral panuveitis and an ischemic cerebellar stroke. The diagnosis of Whipple disease was confirmed by histopathological analysis of adenopathy. The patient was treated with cortico-antibiotic therapy with significant clinical improvement. Although rare, Whipple disease is potentially fatal if left untreated, it must be always be taken into consideration before any panuveitis of an unknown cause, even in the absence of gastrointestinal symptoms.

  3. Bilateral pulmonary infiltrates in association with disseminated actinomycosis.

    PubMed

    Dontfraid, F; Ramphal, R

    1994-07-01

    The most common infectious cause of bilateral upper-lobe pulmonary disease is tuberculosis. However, we recently encountered a patient with bilateral apical infiltrates and multiple soft-tissue abscesses caused by Actinomyces odontolyticus. Other findings included fever, weight loss, and leukocytosis, and the patient's only known source of immunosuppression was a long history of alcoholism. There was no history of diabetes, steroid use, or other chronic underlying disease. The diagnosis was made by culture of drainage fluid from one abscess. Therapy with intravenous penicillin G led to rapid clinical improvement and reduction in the infiltrates. To our knowledge, the presentation of pulmonary infection, with bilateral apical infiltrates due to A. odontolyticus has not been previously reported in the medical literature.

  4. Keratoconus presenting with bilateral simultaneous acute corneal hydrops.

    PubMed

    Bilgin, Burak; Unal, Betül; Unal, Mustafa; Doğan, Erkan; Cetinkaya, Aslı; Akyol, Mahmut; Yücel, Iclal; Akar, Yusuf; Apaydın, Cemil; Ilhan, Deniz

    2013-04-01

    To report a case of unknown keratoconus presenting with bilateral simultaneous acute corneal hydrops. Case report. A case of a 12-year-old male patient with Leber congenital amaurosis (LCA) presented with sudden whitening and lacrimation for 2 days in both eyes simultaneously. At the initial examination, there were bilateral acute corneal hydrops, enophthalmic eyes and roving nystagmus. Ultrasonography revealed clear crystalline lenses and attached retina. Initial management consisted of topical hypertonic solutions, steroids and artificial tears. Bilateral simultaneous acute corneal hydrops has not been reported before in the literature. It may be the presenting sign of keratoconus. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Bilateral multifocal Warthin tumours.

    PubMed

    Deveer, Mehmet; Sahan, Murat; Sivrioglu, Ali Kemal; Celik, Ozgür Ilhan

    2013-05-22

    Warthin tumour, also known as papillary cystadenoma lymphomatosum, is the second most frequent benign tumour of the parotid gland after pleomorphic adenoma. A 57-year-old man was referred to our hospital with bilateral buccal masses without pain. He presented with a 1-year history of the condition and stated that growth of the mass has accelerated during the last 6 months. Ultrasonography examination showed two heterogeneous solid masses. Axial contrast-enhanced CT image revealed bilateral heterogeneous solid masses. The masses showed enhancement after contrast administration (95 HU). Fine needle aspiration cytology was recommended for further analysis and typical benign features of Warthin tumour was obtained. Right parotid gland including the masses was resected completely. 5 weeks later superficial parotidectomy was performed to the left parotid gland. Histological examination revealed cystic tumour in the parenchyma of parotid gland, composed of prominent lymphoid stroma and large epithelial cells with oncocytic features covering it consistent with Warthin tumour.

  6. Bilateral multifocal Warthin tumours

    PubMed Central

    Deveer, Mehmet; Sahan, Murat; Sivrioglu, Ali Kemal; İlhan Celik, Özgür

    2013-01-01

    Warthin tumour, also known as papillary cystadenoma lymphomatosum, is the second most frequent benign tumour of the parotid gland after pleomorphic adenoma. A 57-year-old man was referred to our hospital with bilateral buccal masses without pain. He presented with a 1-year history of the condition and stated that growth of the mass has accelerated during the last 6 months. Ultrasonography examination showed two heterogeneous solid masses. Axial contrast-enhanced CT image revealed bilateral heterogeneous solid masses. The masses showed enhancement after contrast administration (95 HU). Fine needle aspiration cytology was recommended for further analysis and typical benign features of Warthin tumour was obtained. Right parotid gland including the masses was resected completely. 5 weeks later superficial parotidectomy was performed to the left parotid gland. Histological examination revealed cystic tumour in the parenchyma of parotid gland, composed of prominent lymphoid stroma and large epithelial cells with oncocytic features covering it consistent with Warthin tumour. PMID:23704438

  7. Bilateral Cochlear Implantation in Children: Experiences and Considerations

    ERIC Educational Resources Information Center

    Bohnert, Andrea; Spitzlei, Vera; Lippert, Karl L.; Keilmann, Annerose

    2006-01-01

    Between 2000 and 2006, the University Clinic for Ear Nose and Throat and Communication Disorders in Mainz, Germany, performed 41 bilateral cochlear implantations in children. This article addresses some of the factors to be considered in a decision to bilaterally implant a child, including the age of the child at the first implant, the length of…

  8. UNITED STATES/GERMAN TECHNICAL BILATERAL AGREEMENT: PAST, PRESENT & FUTURE

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) and the German Federal Ministry of Education and Research (BMBF) entered into a Bilateral Agreement in 1990 to study each country's efforts in developing and demonstrating remedial technologies. The bilateral agreement is being impl...

  9. Pros and cons of immediately sequential bilateral cataract surgery (ISBCS).

    PubMed

    Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Claoué, Charles

    2016-01-01

    Immediately sequential bilateral cataract surgery (ISBCS) is currently a "hot topic" in ophthalmology. There are well-documented advantages in terms of quicker visual rehabilitation and reduced costs. The risk of bilateral simultaneous endophthalmitis and bilateral blindness is now recognized to be minuscule with the advent of intracameral antibiotics and modern management of endophthalmitis. Refractive surprises are rare for normal eyes and with the use of optical biometry. Where a general anesthetic is indicated for cataract surgery, the risk of death from a second anesthetic is much higher than the risk of blindness. A widely recognized protocol from the International Society of Bilateral Cataract Surgeons needs to be adhered to if surgeons wish to start practicing ISBCS.

  10. Bilateral Total Hip Arthroplasty: 1-Stage or 2-Stage? A Meta-Analysis.

    PubMed

    Shao, Hongyi; Chen, Chi-Lung; Maltenfort, Mitchell G; Restrepo, Camilo; Rothman, Richard H; Chen, Antonia F

    2017-02-01

    Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed in the last 50 years. However, controversies still exist between conducting 1- or 2-stage bilateral THA. Using PubMed, Ovid, Embase, and Cochrane library databases, we searched for papers written between January 1995 and October 2015 that contained the following search terms: "one-stage or two-stage" or "simultaneous or staged," and "hip" and "arthroplasty or replacement." A meta-analysis was conducted with the collected pooled data about major and minor systemic complications, surgical complications, and other perioperative data associated with 1- and 2-stage bilateral THA. Statistical analysis was performed by the Mantel-Haenszel method, and the fixed effect model was used to analyze data. There were 13 studies with 17,762 patients who underwent 1-stage bilateral THA and 46,147 patients who underwent 2-stage bilateral THA. One-stage bilateral THA had a lower risk of major systemic complications, less deep venous thrombosis, and shorter operative time compared with 2-stage bilateral THA. There were no significant differences in death, pulmonary embolism, cardiovascular complication, infections, minor complications, and other surgical complications between procedures. One-stage bilateral THA was superior to 2-stage bilateral THA in terms of major systemic complication, deep venous thrombosis, and surgical time compared with 2-stage bilateral THA. However, this study does not encourage performing 1-stage over 2-stage bilateral THA. Higher evidence level studies are necessary for further analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. KEY COMPARISON: CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

    NASA Astrophysics Data System (ADS)

    Seah, M. P.

    2008-01-01

    CCQM-K32 and P84 were conducted following the pilot study P-38 to demonstrate and document the capability of interested National Metrology Institutes to measure the amount of silicon oxide on silicon wafers expressed as a thickness of SiO2 for nominal thicknesses in the range 1.5 nm to 8 nm. 'Amount of substance' may be expressed in many ways and here the measurand is the thickness of the silicon oxide layer on each of a total of 9 samples of nominal thicknesses in the range 1.5 to 8 nm on (100) and (111) Si substrates, expressed as the thickness of SiO2. This report presents the results from K32 and P84. It includes the data received for the measured values and their associated uncertainties, at 95% confidence, for the 9 samples prior to the deadline for receipt of data. The materials are grown by thermal oxidation in very clean furnaces designed for high quality gate oxides on Si wafers in European and US facilities at the same time as those for the pilot study, P-38. Separate samples were provided to each institute in special containers limiting the carbonaceous contamination to below about 0.3 nm. The 9 samples included 5 samples of ultra-thin SiO2 on (100) orientated wafers of Si and 4 samples of ultra-thin SiO2 on (111) orientated wafers of Si. The measurements from the 11 participating laboratories were conducted using ellipsometry, neutron reflectivity (NR), x-ray photoelectron spectroscopy (XPS) or x-ray reflectivity measurements (XRR), guided by the protocol developed in the pilot study P-38 and reproduced in the Appendix. The measurements are given in tables 2 and 3. A very small correction is then made for the different samples that each laboratory received as in table 4. Where appropriate, method offset values deduced from the pilot study P-38 are given in table 5 leading to comparative data in tables 6 and 7. Values for the key comparison reference values (KCRVs) and their associated uncertainties are made from the weighted means and the expanded

  12. Single-Anesthetic Versus Staged Bilateral Total Hip Arthroplasty: A Matched Cohort Study.

    PubMed

    Houdek, Matthew T; Wyles, Cody C; Watts, Chad D; Wagner, Eric R; Sierra, Rafael J; Trousdale, Robert T; Taunton, Michael J

    2017-01-04

    There is debate regarding the role of single-anesthetic versus staged bilateral total hip arthroplasty (THA) for patients with end-stage bilateral osteoarthritis. Studies have shown that single-anesthetic bilateral THA is associated with systemic complications, but there are limited data comparing patient outcomes in a matched setting of bilateral THA. We identified 94 patients (188 hips) who underwent single-anesthetic bilateral THA. Fifty-seven percent of the patients were male. Patients had a mean age of 52.2 years and body mass index of 27.1 kg/m. They were matched 1:1 on the basis of sex, age (±1 year), and year of surgery (±3 years) to a cohort of patients undergoing staged bilateral THA. In the staged group, there was <1 year between procedures (range, 5 days to 10 months). Mean follow-up was 4 years for each group. Patients in the single-anesthetic group experienced shorter total operating room time and length of stay. There was no difference (hazard ratio [HR] = 0.73, p = 0.50) in the overall revision-free survival in patients undergoing single-anesthetic or staged bilateral THA. The risks of reoperation (HR = 0.69, p = 0.40), complications (HR = 0.83, p = 0.48), and mortality (HR = 0.47, p = 0.10) were similar. Single-anesthetic bilateral THA reduced the total cost of care (by 27%, p = 0.0001). In this matched cohort analysis, single-anesthetic bilateral THA was not associated with an increased risk of revision, reoperation, or postoperative complications, while decreasing cost. In our experience, single-anesthetic bilateral THA is a safe procedure that, for certain patients, offers an excellent means to deal with bilateral hip osteoarthritis. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. Spared ability to recognise fear from static and moving whole-body cues following bilateral amygdala damage

    PubMed Central

    Atkinson, Anthony P.; Heberlein, Andrea S.; Adolphs, Ralph

    2007-01-01

    Bilateral amygdala lesions impair the ability to identify certain emotions, especially fear, from facial expressions, and neuroimaging studies have demonstrated differential amygdala activation as a function of the emotional expression of faces, even under conditions of subliminal presentation, and again especially for fear. Yet the amygdala's role in processing emotion from other classes of stimuli remains poorly understood. On the basis of its known connectivity as well as prior studies in humans and animals, we hypothesised that the amygdala would be important also for the recognition of fear from body expressions. To test this hypothesis, we assessed a patient (S.M.) with complete bilateral amygdala lesions who is known to be severely impaired at recognising fear from faces. S.M. completed a battery of tasks involving forced-choice labelling and rating of the emotions in two sets of dynamic body movement stimuli, as well as in a set of static body postures. Unexpectedly, S.M.'s performance was completely normal. We replicated the finding in a second rare subject with bilateral lesions entirely confined to the amygdala. Compared to healthy comparison subjects, neither of the amygdala lesion subjects was impaired in identifying fear from any of these displays. Thus, whatever the role of the amygdala in processing whole-body fear cues, it is apparently not necessary for the normal recognition of fear from either static or dynamic body expressions. PMID:17561172

  14. Bilateral asymmetry of skin temperature is not related to bilateral asymmetry of crank torque during an incremental cycling exercise to exhaustion

    PubMed Central

    Formenti, Damiano; Ludwig, Nicola; Gargano, Marco; Bosio, Andrea; Rampinini, Ermanno; Alberti, Giampietro

    2018-01-01

    Although moderate relationships (|r| ∼ 0.5) were reported between skin temperature and performance-related variables (e.g., kinetic), it remains unclear whether skin temperature asymmetry reflects muscle force imbalance in cycling. Therefore, the aim of this study was to assess whether a relationship exists between kinetic and thermal asymmetry during a fatiguing exercise. Ten elite cyclists were enrolled and tested on a maximal incremental cycling test. Peak crank torques of both legs were obtained at the initial and final workload. Likewise, bilateral skin temperatures were recorded before and after exercise. Asymmetric indexes were also calculated for kinetic (AIK) and skin temperature (AIT) outcomes. The bilateral peak crank torques showed a larger difference at the final compared to the initial workload (p < 0.05) of the incremental exercise. Conversely, the bilateral skin temperature did not show any differences at both initial and final workload (p > 0.05). Additionally, trivial relationships were reported between AIK and AIT (−0.3 < r < 0.2) at the initial and final workload. The obtained results showed that changes in bilateral kinetic values did not reflect concurrent changes in bilateral skin temperatures. This finding emphasizes the difficulty of associating the asymmetry of skin temperature with those of muscle effort in elite cyclists. Lastly, our study also provided further insights on thermal skin responses during exhaustive cycling exercise in very highly-trained athletes. PMID:29507831

  15. Unilateral versus bilateral stent insertion for malignant hilar biliary obstruction.

    PubMed

    Chang, Gang; Xia, Feng-Fei; Li, Hong-Fu; Niu, Su; Xu, Yuan-Shun

    2017-11-01

    To determine the clinical efficiency and long-term outcomes between unilateral and bilateral stent insertion in patients with malignant hilar biliary obstruction. From August 2012 to February 2016, 63 consecutive patients with malignant hilar biliary obstruction were treated with unilateral or bilateral stent insertion at our center. The bilateral stents were inserted using the side-by-side technique. The clinical efficiency and long-term outcomes were compared between the two groups. Unilateral and bilateral stent insertions were successfully performed in 31 of 33 and 27 of 30 patients, respectively (P = 0.912). No procedure-related complication occurred. Clinical success was achieved in 29 of 31 patients in the unilateral stent group and in 26 of 27 patients in the bilateral stent group (P = 0.637). During the follow-up, re-obstruction of stent occurred in five patients in the unilateral stent group and in three patients in the bilateral stent group (P = 0.58). The significant differences were not observed in the stent patency time (368 vs. 387 days, P = 0.685) and survival (200 vs. 198 days, P = 0.751) between two groups. Based on the univariate and multivariate analyses, the independent risk factors for decreasing the survival time included higher Eastern Cooperative Oncology Group performance status (P = 0.018), higher alanine aminotransferase level (P = 0.009), and absence of anticancer treatment after stent insertion (P = 0.002). Compared to bilateral stent insertion for malignant hilar biliary obstruction, unilateral stent insertion can provide comparable clinical efficiency and long-term outcomes.

  16. BILATERAL CHOROIDAL EXCAVATION IN JUVENILE LOCALIZED SCLERODERMA.

    PubMed

    Franklin, Mackenzie L; Day, Shelley

    2018-01-01

    To describe a case of bilateral choroidal excavation in a patient with juvenile localized scleroderma. Case report. An asymptomatic 12-year-old boy with localized scleroderma presented for examination and was found to have bilateral areas of choroidal excavation temporal to the fovea. Previous reports of ocular complications of localized scleroderma have primarily described adnexal and anterior segment changes. This is the second report of choroidal changes in a patient with localized scleroderma, and the first in a pediatric patient.

  17. Cutaneous metastasis of bilateral renal cell carcinoma.

    PubMed

    Abbasi, Fariba; Alizadeh, Mansur; Noroozinia, Farahnaz; Moradi, Amin

    2013-01-01

    Renal cell carcinoma (RCC) is a malignant lethal tumour with high potential of metastasis. However, metastasis from RCC to the skin is much less common. It is virtually a sign of poor prognosis. We represent a 42 years old man with bilateral RCC of clear cell type followed by metastasis to the scalp one month later. In this case the relatively young age of the patient, bilaterality of RCC and occurance of skin metastasis in the absence of recurrent kidney tumour are interesting.

  18. Early Vocabulary Development in Children with Bilateral Cochlear Implants

    ERIC Educational Resources Information Center

    Välimaa, Taina; Kunnari, Sari; Laukkanen-Nevala, Päivi; Lonka, Eila

    2018-01-01

    Background: Children with unilateral cochlear implants (CIs) may have delayed vocabulary development for an extended period after implantation. Bilateral cochlear implantation is reported to be associated with improved sound localization and enhanced speech perception in noise. This study proposed that bilateral implantation might also promote…

  19. Dysphagia in a patient with bilateral medial medullary infarcts.

    PubMed

    Paliwal, Vimal K; Kalita, Jayanti; Misra, Usha K

    2009-09-01

    Bilateral medial medullary infarct is a rare stroke syndrome and only a handful of cases have been described. Dysphagia as a manifestation of medullary infarcts is well recognized but often associated with lateral medullary infarct. Bilateral medial medullary infarcts are commonly associated with severe dysphagia in addition to a number of other signs and symptoms. We describe a patient who had bilateral medial medullary infarct with severe dysphagia in addition to quadriplegia and respiratory difficulty, and analyze infarct topography with respect to dysphagia, risk factors, vascular territories involved, and prognosis in view of previously reported cases.

  20. Physician opinions regarding elective bilateral salpingectomy with hysterectomy and for sterilization.

    PubMed

    Gill, Sarah E; Mills, Benjie B

    2013-01-01

    To gather opinions about the benefits and concerns of performing bilateral salpingectomy without oophorectomy during hysterectomy for benign indications and as a sterilization procedure. Survey study (Canadian Task Force classification III). Practicing physicians in US institutions that have obstetrics and gynecology residency programs listed on the FREIDA website were surveyed electronically. A validated, standardized questionnaire designed to gather opinions about bilateral salpingectomy performed during hysterectomy or for sterilization was administered via SurveyMonkey to practitioners of obstetrics and gynecology. Results were compiled and presented as percentages of total responders. A total of 234 surveys were returned. Fifty-four percent of physicians perform bilateral salpingectomy during hysterectomy, most commonly to reduce the risks of cancer (75%) and repeat operation (49.1%). Of the 45.5% of physicians who do not perform bilateral salpingectomy during hysterectomy, most (69.4%) believe there is no benefit. Fifty-eight percent of practitioners believe that bilateral salpingectomy is the most effective method of sterilization after age 35 years but choose this method only in patients in whom one sterilization procedure has failed or because of tubal disease. Only 7.2% of surgeons prefer it as an interval sterilization procedure. Most practitioners believe that bilateral salpingectomy is beneficial. Most also believe that bilateral salpingectomy is the most effective sterilization procedure; however, only 7.2% use this method as an interval procedure. More data are needed to evaluate the prophylactic effect of bilateral salpingectomy against postoperative sequelae. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  1. Correct, fake and absent pre-information does not affect the occurrence and magnitude of the bilateral force deficit.

    PubMed

    Donath, Lars; Siebert, Tobias; Faude, Oliver; Puta, Christian

    2014-05-01

    The present study examined whether different pre-information conditions could lead to a volitional modulation of the occurrence and magnitude of the bilateral force deficit (BFD) during isometric leg press. Twenty trained male adults (age: 24.5 ± 1.7 years; weight: 77.5 ± 7.1 kg; height: 1.81 ± 0.05 m) were examined on three days within a week. Isometric leg press was performed on a negatively inclined leg press slide. Each participant completed three maximal isometric strength test sessions with different pre-information conditions given in a graphical chart: no pre-information (NPI; first day), false pre-information (FPI; bilateral force > sum of unilateral forces; second or third day) and correct pre-information (CPI; bilateral force < sum of unilateral forces; second or third day) during bilateral, unilateral-left and unilateral-right leg-press. The sum of left- and right-sided force values were calculated for bilateral (FBL = FBL_left + FBL_right) and unilateral (FUL = FUL_left + FUL_right) analyses. Force data for NPI revealed: Mean (SD): FUL_NPI = 3023 N (435) vs. FBL_NPI = 2812 (453); FPI showed FUL_FPI = 3013 N (459) vs. FBL_FPI = 2843 (446) and the CPI revealed FUL_CPI = 3035 (425) vs. FBL_CPI = 2844 (385). The three (no, false, correct) x 2 (FUL, FBL) rANOVA revealed a high significant main effect of Force (F = 61.82, p < 0.001). No significant main effect of the factor Condition and no significant interaction between Force x Condition was observed. The BFD does not rely on the trueness of the given pre-information (no, false, correct). Cognition-based volitional influences on the BFD on supra-spinal level seem negligible. Key pointsBFD is reliable occurring phenomenonAvailable theoretical knowledge does not affect the BFDAlternating sport should include alternating strength exercises.

  2. Bilateral parotitis as the initial presentation of childhood sarcoidosis.

    PubMed

    Banks, Gretchen C; Kirse, Daniel J; Anthony, Evelyn; Bergman, Simon; Shetty, Avinash K

    2013-01-01

    The differential diagnosis of bilateral parotid gland enlargement in children includes infectious, inflammatory, and neoplastic disorders. We present the case of a 13-year-old male who presented with a 5-week history of bilateral parotid swelling. On exam, both parotid glands were nontender, smooth, and diffusely enlarged. He had slightly elevated inflammatory markers, but other lab results were normal. A neck CT revealed symmetric enlargement of the parotid, submandibular, and sublingual glands. A chest CT revealed scattered peripheral pulmonary nodules and bilateral hilar adenopathy. A parotid gland biopsy showed multiple noncaseating granulomas with multinucleated giant cells surrounded by lymphocytes, consistent with the diagnosis of sarcoidosis. Special stains for acid-fast and fungal organisms were negative. Using this illustrative case, we discuss the differential diagnosis of bilateral salivary gland enlargement in children and review the etiology, diagnosis, clinical manifestations, and treatment of pediatric sarcoidosis. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.; Rujirat, N.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device. Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 2.6 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Binaural Speech Understanding With Bilateral Cochlear Implants in Reverberation.

    PubMed

    Kokkinakis, Kostas

    2018-03-08

    The purpose of this study was to investigate whether bilateral cochlear implant (CI) listeners who are fitted with clinical processors are able to benefit from binaural advantages under reverberant conditions. Another aim of this contribution was to determine whether the magnitude of each binaural advantage observed inside a highly reverberant environment differs significantly from the magnitude measured in a near-anechoic environment. Ten adults with postlingual deafness who are bilateral CI users fitted with either Nucleus 5 or Nucleus 6 clinical sound processors (Cochlear Corporation) participated in this study. Speech reception thresholds were measured in sound field and 2 different reverberation conditions (0.06 and 0.6 s) as a function of the listening condition (left, right, both) and the noise spatial location (left, front, right). The presence of the binaural effects of head-shadow, squelch, summation, and spatial release from masking in the 2 different reverberation conditions tested was determined using nonparametric statistical analysis. In the bilateral population tested, when the ambient reverberation time was equal to 0.6 s, results indicated strong positive effects of head-shadow and a weaker spatial release from masking advantage, whereas binaural squelch and summation contributed no statistically significant benefit to bilateral performance under this acoustic condition. These findings are consistent with those of previous studies, which have demonstrated that head-shadow yields the most pronounced advantage in noise. The finding that spatial release from masking produced little to almost no benefit in bilateral listeners is consistent with the hypothesis that additive reverberation degrades spatial cues and negatively affects binaural performance. The magnitude of 4 different binaural advantages was measured on the same group of bilateral CI subjects fitted with clinical processors in 2 different reverberation conditions. The results of this work

  5. A case of simultaneous bilateral spontaneous pneumothorax after the Nuss procedure.

    PubMed

    Matsuoka, Shunichiro; Miyazawa, Masahisa; Kashimoto, Kentaro; Kobayashi, Hiroaki; Mitsui, Fumihiko; Tsunoda, Hajime; Kunitomo, Kazuyoshi; Chisuwa, Hisanao; Haba, Yoshiaki

    2016-06-01

    We present a case of simultaneous bilateral spontaneous pneumothorax caused by a pleuro-pleural communication formed from Nuss procedure for pectus excavatum. A 17-year-old man with a history of Nuss operation complained chest pain and dyspnea. A chest roentgenogram demonstrated a tiny bilateral pneumothorax and two metallic bars inserted at the Nuss procedure. Computed tomography revealed furthermore a bulla in the apex of the left lung. The bilateral pneumothorax critically deteriorated after 4 days from onset and urgent bilateral chest drainages were performed. Nevertheless the drainages the full expansion of both lungs was not obtained and air leakage only from left side was continued. A video-assisted left bullectomy was performed 9 days after the tube insertion. The two bars penetrating anterior mediastinal pleura were thought to be a cause of the simultaneous bilateral spontaneous pneumothorax.

  6. A Case of Bilateral Pigment Dispersion Syndrome Following Many Years of Uninterrupted Treatment With Atropine 1% for Bilateral Congenital Cataracts.

    PubMed

    Gizzi, Corrado; Mohamed-Noriega, Jibran; Murdoch, Ian

    2017-10-01

    Describe an unusual case of bilateral pigment dispersion syndrome (PDS) following years of uninterrupted treatment with atropine 1% for bilateral congenital cataracts, speculate on potential mechanisms leading to this condition. This is a case report. A 45-year-old white patient on long-term treatment with atropine 1% ointment since his infancy for bilateral congenital cataracts developed PDS with secondary ocular hypertension. The patient showed all the hallmarks of PDS with secondary ocular hypertension. An anterior segment Swept-Source optical coherence tomography was obtained to review the iris profile. The patient showed good pressure response to topical prostaglandin therapy. This is the second case report of PDS in a patient with chronic use of topical atropine. The proposed mechanisms for pigment dispersion are discussed and the possibility raised of dispersion being a potential side effect of the drug.

  7. Perceptual benefit and functional outcomes for children using sequential bilateral cochlear implants.

    PubMed

    Galvin, Karyn Louise; Mok, Mansze; Dowell, Richard C

    2007-08-01

    To evaluate the additional perceptual benefit provided to children through the use of two cochlear implants in comparison to one after 6 to 13 mo experience with sequential bilateral implants. A second cochlear implant was received by 11 children. The principal selection criteria were being age 4 to 15 yr with a bilateral profound hearing loss and being a consistent user of a first implant with a commitment to use of a second implant. Horizontal localization was assessed by using pink noise bursts presented from a 180 degrees , eight-loudspeaker array. Speech perception was assessed by using a four-alternative forced-choice spondee test, with speech presented from in front and adaptive background noise presented from 90 degrees to the left or right. Both tests were completed in the first implant alone and bilateral conditions. A questionnaire measured the pre- to postoperative change in the parent's ratings of the child's performance in specific listening situations. Items were related to speech perception, spatial hearing, or other qualities of hearing. Regular parental reports of device use, attitude and performance were collected. Most subjects were assessed at 6 mo after surgery, with two assessed at 13 mo. The 11 subjects demonstrated a great range of outcomes. For one subject, only anecdotal data were collected. Speech perception testing indicated that when noise was presented ipsilateral to the first implant, 8 of 10 subjects showed a benefit in the bilateral condition. None of the nine subjects tested showed a benefit when noise was contralateral to the first implant. Generally, there was no benefit to localization in the bilateral condition. For eight subjects, postoperative performance ratings were generally higher than preoperative ratings, particularly in the spatial hearing section. Anecdotal reports indicated that most subjects had a negative attitude toward, and gained limited experience with, the second implant alone. The subjects developed a range

  8. Muscle activity of the core during bilateral, unilateral, seated and standing resistance exercise.

    PubMed

    Saeterbakken, Atle Hole; Fimland, Marius Steiro

    2012-05-01

    Little is known about the effect of performing common resistance exercises standing compared to seated and unilaterally compared to bilaterally on muscle activation of the core. Thus, the purpose of this study was to compare the electromyographic activity (EMG) of the superficial core muscles (i.e. rectus abdominis, external oblique and erector spinae) between seated, standing, bilateral and unilateral dumbbell shoulder presses. 15 healthy males performed five repetitions at 80% of one-repetition maximum of the exercises in randomized order. Results were analyzed with a two-way analysis of variance and a Bonferroni post hoc test. The position × exercise interaction was significantly different for rectus abdominis (P = 0.016), but not for external oblique (P = 0.100) and erector spinae (P = 0.151). The following EMG results were observed: For rectus abdominis: ~49% lower in seated bilateral versus unilateral (P < 0.001), similar in standing bilateral versus unilateral (P = 0.408), ~81% lower in bilateral seated versus standing (P < 0.001), ~59% lower in unilateral seated versus standing (P < 0.001); For external oblique: ~81% lower in seated bilateral versus unilateral (P < 0.001), ~68% lower in standing bilateral than unilateral (P < 0.001), ~58% lower in bilateral seated versus standing (P < 0.001), ~28% lower in unilateral seated versus standing (P = 0.002); For erector spinae: similar in seated bilateral versus unilateral (P = 0.737), ~18% lower in standing bilateral versus unilateral (P = 0.001), similar in seated versus standing bilateral (P = 0.480) and unilateral (P = 0.690). In conclusion, to enhance neuromuscular activation of the superficial core muscles, standing exercises should be used instead of seated exercises, and unilateral exercises should be used instead of bilateral exercises.

  9. Spontaneous bilateral fracture of patella.

    PubMed

    Moretti, Biagio; Speciale, Domenico; Garofalo, Raffaele; Moretti, Lorenzo; Patella, Silvio; Patella, Vittorio

    2008-03-01

    Bilateral patellae fractures represent a rare entity, accounting for approximately 2.9% of all lesions interesting in this anatomical district. In most cases found in the published work, they are described as stress fractures or as complications of chronic diseases such as osteoporosis, renal failure and secondary hyperparathyroidism. Although many pathogenetic mechanisms have been supposed, none have been proved for certain. Insufficiency fractures of the patellae are rare events and no data has been published on their incidence. We present a case of bilateral fracture of the patellae due to an indirect trauma occurring in an 85-year-old patient affected by Parkinson's disease, osteoporosis and diffuse degenerative osteoarthritis. X-ray of the knees (anteroposterior and lateral) and magnetic resonance imaging evaluation confirmed the fractures. The patient was treated conservatively. She had a good result, returning to her previous autonomous ambulation. This case is unusual because there was no direct trauma to the knees because of bilaterality, but confirmed previous observations about insufficiency fractures of patellae in the presence of comorbidity. Insufficiency fractures of patellae can be an insidious condition in elderly people. Prepatellar pain, a common symptom in the relapse phase of degenerative arthritis of the knee, should not be underestimated, particularly in patients with diseases influencing metabolism of bone and with an elevated risk of fall. A periodical clinical and instrumental follow up should be done in these patient. Moreover, we underline the necessity of a multidisciplinary approach.

  10. Compensation Following Bilateral Vestibular Damage

    PubMed Central

    McCall, Andrew A.; Yates, Bill J.

    2011-01-01

    Bilateral loss of vestibular inputs affects far fewer patients than unilateral inner ear damage, and thus has been understudied. In both animal subjects and human patients, bilateral vestibular hypofunction (BVH) produces a variety of clinical problems, including impaired balance control, inability to maintain stable blood pressure during postural changes, difficulty in visual targeting of images, and disturbances in spatial memory and navigational performance. Experiments in animals have shown that non-labyrinthine inputs to the vestibular nuclei are rapidly amplified following the onset of BVH, which may explain the recovery of postural stability and orthostatic tolerance that occurs within 10 days. However, the loss of the vestibulo-ocular reflex and degraded spatial cognition appear to be permanent in animals with BVH. Current concepts of the compensatory mechanisms in humans with BVH are largely inferential, as there is a lack of data from patients early in the disease process. Translation of animal studies of compensation for BVH into therapeutic strategies and subsequent application in the clinic is the most likely route to improve treatment. In addition to physical therapy, two types of prosthetic devices have been proposed to treat individuals with bilateral loss of vestibular inputs: those that provide tactile stimulation to indicate body position in space, and those that deliver electrical stimuli to branches of the vestibular nerve in accordance with head movements. The relative efficacy of these two treatment paradigms, and whether they can be combined to facilitate recovery, is yet to be ascertained. PMID:22207864

  11. Repair of bilateral cleft lip and its variants

    PubMed Central

    Mulliken, John B.

    2009-01-01

    The surgeon who lifts a scalpel to repair a bilateral cleft lip and nasal deformity is accountable for: 1) precise craftsmanship based on three-dimensional features and four-dimensional changes; 2) periodic assessment throughout the child's growth; and 3) technical modifications during primary closure based on knowledge gained from long-term follow-up evaluation. These children should not have to endure the stares prompted by nasolabial stigmata that result from outdated concepts and technical misadventures. The principles for repair of bilateral complete cleft lip have evolved to such a level that the child's appearance should be equivalent to, or surpass, that of a unilateral complete cleft lip. These same principles also apply to the repair of the variants of bilateral cleft lip, although strategies and execution differ slightly. PMID:19884685

  12. COOMET.QM-K93 (COOMET 615/RU/13): key comparison in the field of measuring of the ethanol amount fraction in nitrogen (120 μmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Efremova, O. V.; Fatina, O. V.; Orshanskaia, A. A.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.

    2016-01-01

    The relevance of the COOMET.QM-K93 comparison is founded on paying particular attention to reliability of measurements which are performed during the medical examination of drivers of vehicles in order to assess the degree of alcoholic intoxication. Standard gas mixtures of ethanol in nitrogen in cylinders under pressure play a key role in providing metrological assurance of breath-alcohol analyzers. Participating laboratories: VNIIM and Ukrmetrteststandart. This comparison was carried out in 2014-2015. This supplementary comparison supports CMC claims for: ethanol in the range 50-500 μmol/mol in a matrix of either nitrogen or synthetic air. Results: The results are consistent with the reference values. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. On-site comparison of Quantum Hall Effect resistance standards of the CMI and the BIPM: ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Kučera, Jan; Vojáčková, Lucie

    2017-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Czech Metrology Institute (CMI) and of the Bureau International des Poids et Mesures (BIPM) was made in April 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 6 parts in 1010 with a relative combined standard uncertainty uc = 25 × 10-10. Measurements of 10000 Ω/100 Ω and 100 Ω/1 Ω ratios agreed to 11 parts in 1010 with uc = 22 × 10-10 and to 33 parts in 1010 with uc = 32 × 10-10, respectively. The influence of the current reversal time has been systematically investigated in order to take into account possible errors due to the Peltier effect, which may be particularly large in 1 Ω standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral and symmetrical tinea mammae.

    PubMed

    Yilmaz, Murat; Kavak, Ayse; Yamaner, Nalan Jale

    2013-09-14

    Tinea corporis has rarely been reported in some locations such as on the breast skin as unilaterally. Herein, we present a case of bilateral tinea mammae, which has not been reported before in English language literature to our knowledge.

  15. Bilateral filtering using the full noise covariance matrix applied to x-ray phase-contrast computed tomography.

    PubMed

    Allner, S; Koehler, T; Fehringer, A; Birnbacher, L; Willner, M; Pfeiffer, F; Noël, P B

    2016-05-21

    The purpose of this work is to develop an image-based de-noising algorithm that exploits complementary information and noise statistics from multi-modal images, as they emerge in x-ray tomography techniques, for instance grating-based phase-contrast CT and spectral CT. Among the noise reduction methods, image-based de-noising is one popular approach and the so-called bilateral filter is a well known algorithm for edge-preserving filtering. We developed a generalization of the bilateral filter for the case where the imaging system provides two or more perfectly aligned images. The proposed generalization is statistically motivated and takes the full second order noise statistics of these images into account. In particular, it includes a noise correlation between the images and spatial noise correlation within the same image. The novel generalized three-dimensional bilateral filter is applied to the attenuation and phase images created with filtered backprojection reconstructions from grating-based phase-contrast tomography. In comparison to established bilateral filters, we obtain improved noise reduction and at the same time a better preservation of edges in the images on the examples of a simulated soft-tissue phantom, a human cerebellum and a human artery sample. The applied full noise covariance is determined via cross-correlation of the image noise. The filter results yield an improved feature recovery based on enhanced noise suppression and edge preservation as shown here on the example of attenuation and phase images captured with grating-based phase-contrast computed tomography. This is supported by quantitative image analysis. Without being bound to phase-contrast imaging, this generalized filter is applicable to any kind of noise-afflicted image data with or without noise correlation. Therefore, it can be utilized in various imaging applications and fields.

  16. Bilateral External Iliac Artery Dissection in a Middle-Aged Male Athlete

    PubMed Central

    Yamanaka, Yasushi; Yoshida, Tetsuya; Nagaoka, Eiki

    2017-01-01

    We present the case of a bilateral external iliac artery (EIA) dissection in a 44-year-old male athlete. The patient was referred to our department for right lower abdominal pain without claudication during single squatting. His athletic history included participation in approximately five athletic events per year. Contrast-enhanced computed tomography (CT) revealed bilateral EIA dissection and right renal infarction. Following medical treatment for his hypertension and considering his medical history, a bilateral EIA replacement with 8-mm Dacron straight grafts was performed on the 24th day after hospital admission. Postoperative contrast-enhanced CT revealed good bilateral graft patency and perfusion following surgery. PMID:29515713

  17. Bilateral External Iliac Artery Dissection in a Middle-Aged Male Athlete.

    PubMed

    Yamanaka, Yasushi; Yoshida, Tetsuya; Nagaoka, Eiki

    2017-12-25

    We present the case of a bilateral external iliac artery (EIA) dissection in a 44-year-old male athlete. The patient was referred to our department for right lower abdominal pain without claudication during single squatting. His athletic history included participation in approximately five athletic events per year. Contrast-enhanced computed tomography (CT) revealed bilateral EIA dissection and right renal infarction. Following medical treatment for his hypertension and considering his medical history, a bilateral EIA replacement with 8-mm Dacron straight grafts was performed on the 24th day after hospital admission. Postoperative contrast-enhanced CT revealed good bilateral graft patency and perfusion following surgery.

  18. Bilateral posterior fracture-dislocation of the shoulder: Report of two cases

    PubMed Central

    Claro, Rui; Sousa, Ricardo; Massada, Marta; Ramos, Joaquim; Lourenço, José M.

    2009-01-01

    Bilateral posterior fracture-dislocation of the shoulder is a very rare injury. Almost 50% of bilateral posterior dislocations are due to a convulsive seizure, rising to 90% if the dislocations are associated with fractures. Electric shock accounts for less than 5% of bilateral posterior dislocations of the shoulder. A systematization of the clinical and radiological approach, followed by an early diagnosis and proper surgical treatment is essential. Authors report 2 cases of bilateral posterior fracture-dislocation of the shoulder, one caused by a convulsive seizure and the other by an electric shock. A review of literature and a treatment protocol are also presented. PMID:20661400

  19. Bilateral double level tibial lengthening in dwarfism.

    PubMed

    Burghardt, Rolf D; Yoshino, Koichi; Kashiwagi, Naoya; Yoshino, Shigeo; Bhave, Anil; Paley, Dror; Herzenberg, John E

    2015-12-01

    Outcome assessment after double level tibial lengthening in patients with dwarfism. Fourteen patients with dwarfism were analyzed after bilateral simultaneous double level tibial lengthening. Average age was 15.1 years. Average lengthening was 13.5 cm. The two levels were lengthened by an average of 7.5 cm proximally and 6.0 cm distally. Concomitant deformities were also addressed during lengthening. External fixation treatment time averaged 8.8 months. Healing index averaged 0.7 months/cm. Bilateral tibial lengthening for dwarfism is difficult, but the results are usually quite gratifying.

  20. Inducing comprehension in the bilateral poor reader.

    PubMed

    Rattan, G; Dean, R S; Lowrie, R E

    1987-09-01

    The comprehension effects of changes in the spatial configuration of prose were examined with reading disabled children who differed in laterality preference. Specifically, 24 learning disabled boys were presented with prose materials in a standard, phrased, and backward (right to left) fashion. Measures of comprehension showed that text in the phrased and backward conditions differentially facilitated comprehension for the more bilateral subjects but had little effect on more right lateralized subjects. The results were discussed in terms of the instructional implications of alterations in the visual-spatial arrangement of prose materials for bilateral readers.

  1. The effects of bilateral presentations on lateralized lexical decision.

    PubMed

    Fernandino, Leonardo; Iacoboni, Marco; Zaidel, Eran

    2007-06-01

    We investigated how lateralized lexical decision is affected by the presence of distractors in the visual hemifield contralateral to the target. The study had three goals: first, to determine how the presence of a distractor (either a word or a pseudoword) affects visual field differences in the processing of the target; second, to identify the stage of the process in which the distractor is affecting the decision about the target; and third, to determine whether the interaction between the lexicality of the target and the lexicality of the distractor ("lexical redundancy effect") is due to facilitation or inhibition of lexical processing. Unilateral and bilateral trials were presented in separate blocks. Target stimuli were always underlined. Regarding our first goal, we found that bilateral presentations (a) increased the effect of visual hemifield of presentation (right visual field advantage) for words by slowing down the processing of word targets presented to the left visual field, and (b) produced an interaction between visual hemifield of presentation (VF) and target lexicality (TLex), which implies the use of different strategies by the two hemispheres in lexical processing. For our second goal of determining the processing stage that is affected by the distractor, we introduced a third condition in which targets were always accompanied by "perceptual" distractors consisting of sequences of the letter "x" (e.g., xxxx). Performance on these trials indicated that most of the interaction occurs during lexical access (after basic perceptual analysis but before response programming). Finally, a comparison between performance patterns on the trials containing perceptual and lexical distractors indicated that the lexical redundancy effect is mainly due to inhibition of word processing by pseudoword distractors.

  2. Perioperative spontaneous bilateral suprachoroidal hemorrhage

    PubMed Central

    Haridas, Anjana; Litwin, Andre S.; Coker, Timothy

    2011-01-01

    Summary Suprachoroidal hemorrhage is a rare condition, occurring most commonly in the perioperative period, although cases of unilateral spontaneous hemorrhages have been reported. We report a case of bilateral spontaneous suprachoroidal hemorrhage and discuss the potential causative factors. PMID:23362387

  3. Bilateral cerebrovascular accidents in incontinentia pigmenti.

    PubMed

    Fiorillo, Loretta; Sinclair, D Barry; O'Byrne, Mary L; Krol, Alfons L

    2003-07-01

    Incontinentia Pigmenti is an X-linked dominant neurocutaneous disorder with central nervous system manifestations in 30% of cases, including seizures and mental retardation. Ischemic or hemorrhagic cerebrovascular accidents have been reported rarely in incontinentia pigmenti. Chart review and literature search was performed following identification of the index case. We describe a patient with incontinentia pigmenti who developed bilateral cerebrovascular accidents in the neonatal period, with resultant severe neurologic sequelae. This is the second reported case of bilateral cerebrovascular accidents in a patient with incontinentia pigmenti. This finding may be secondary to cerebrovascular anomalies, similar to those observed in the retina. Recognition of cerebrovascular accidents as a complication of incontinentia pigmenti will hopefully lead to earlier recognition and treatment.

  4. Bilateral limbic system destruction in man

    PubMed Central

    Feinstein, Justin S.; Rudrauf, David; Khalsa, Sahib S.; Cassell, Martin D.; Bruss, Joel; Grabowski, Thomas J.; Tranel, Daniel

    2010-01-01

    We report here a case study of a rare neurological patient with bilateral brain damage encompassing a substantial portion of the so-called “limbic system.” The patient, Roger, has been studied in our laboratory for over 14 years and the current article presents his complete neuroanatomical and neuropsychological profiles. The brain damage occurred in 1980 following an episode of herpes simplex encephalitis. The amount of destroyed neural tissue is extensive and includes bilateral damage to core limbic and paralimbic regions, including the hippocampus, amygdala, parahippocampal gyrus, temporal poles, orbitofrontal cortex, basal forebrain, anterior cingulate cortex, and insular cortex. The right hemisphere is more extensively affected than the left, although the lesions are largely bilateral. Despite the magnitude of his brain damage, Roger has a normal IQ, average to above average attention, working memory, and executive functioning skills, and very good speech and language abilities. In fact, his only obvious presenting deficits are a dense global amnesia and a severe anosmia and ageusia. Roger's case presents a rare opportunity to advance our understanding of the critical functions underlying the human limbic system, and the neuropsychological and neuroanatomical data presented here provide a critical foundation for such investigations. PMID:19763994

  5. Simultaneous bilateral distal biceps tendon repair: case report.

    PubMed

    Storti, Thiago Medeiros; Paniago, Alexandre Firmino; Faria, Rafael Salomon Silva

    2017-01-01

    Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  6. Bilateral Nasolabial Cyst as a Rare Case Report

    PubMed Central

    Cebi, Işıl Taylan; Karataş, Abdullah; Yüce, Turgut; Şalvız, Mehti; Koçak, Ayhan; Selçuk, Tuba

    2016-01-01

    The etiology, clinical features, and treatment of an extremely rare case of a bilateral nasolabial cyst have been evaluated in this report. A 60-year-old female presented to our clinic with a pain-free swelling above the upper lip for a year and obstruction of the left nasal cavity for two months. On undergoing a physical ENT examination, she showed bulging of both nasal fossae and effacement of the bilateral nasolabial groove with a fluctuating smooth mass. A paranasal sinus CT scan showed a smooth, ovoid mass of 20×13 mm at the right side and 26×22 mm at the left side occupying the floor of the nasal fossa and restricted to the soft parts of the premaxillary region, without any bony destruction. The patient underwent surgical excision under general anesthesia via sublabial approach. Histopathology confirmed the diagnosis of bilateral nasolabial cyst. The patient was asymptomatic during 18-month of postoperative follow-up. Bilateral nasolabial cysts should be considered in the differential diagnosis of cystic masses of the nasal vestibule and deformities of the premaxillary region. Although endonasal endoscopic cyst marsupialization is a relatively new treatment, surgical resection with the sublabial approach is the treatment of choice. PMID:29392022

  7. Case Report: Bilateral reexpansion pulmonary edema following treatment of a unilateral hemothorax

    PubMed Central

    de Wolf, Steven P; Deunk, Jaap; Cornet, Alexander D; Elbers, Paul WG

    2014-01-01

    Bilateral re-expansion pulmonary edema (RPE) is an extremely rare entity. We report the unique case of bilateral RPE following a traumatic, unilateral hemopneumothorax in a young healthy male. Bilateral RPE occurred only one hour after drainage of a unilateral hemopneumothorax. The patient was treated with diuretics and supplemental oxygen. Diagnosis was confirmed by excluding other causes, using laboratory findings, chest radiography, pulmonary and cardiac ultrasound and high resolution computed tomography. His recovery was uneventful. The pathophysiology of bilateral RPE is not well known. Treatment is mainly supportive and consists of diuretics, mechanical ventilation, inotropes and steroids. In case of a pulmonary deterioration after the drainage of a traumatic pneumothorax, bilateral RPE should be considered after exclusion of more common causes of dyspnea. PMID:25713699

  8. Bilateral assessment of functional tasks for robot-assisted therapy applications

    PubMed Central

    Wang, Sarah; Bai, Ping; Strachota, Elaine; Tchekanov, Guennady; Melbye, Jeff; McGuire, John

    2011-01-01

    This article presents a novel evaluation system along with methods to evaluate bilateral coordination of arm function on activities of daily living tasks before and after robot-assisted therapy. An affordable bilateral assessment system (BiAS) consisting of two mini-passive measuring units modeled as three degree of freedom robots is described. The process for evaluating functional tasks using the BiAS is presented and we demonstrate its ability to measure wrist kinematic trajectories. Three metrics, phase difference, movement overlap, and task completion time, are used to evaluate the BiAS system on a bilateral symmetric (bi-drink) and a bilateral asymmetric (bi-pour) functional task. Wrist position and velocity trajectories are evaluated using these metrics to provide insight into temporal and spatial bilateral deficits after stroke. The BiAS system quantified movements of the wrists during functional tasks and detected differences in impaired and unimpaired arm movements. Case studies showed that stroke patients compared to healthy subjects move slower and are less likely to use their arm simultaneously even when the functional task requires simultaneous movement. After robot-assisted therapy, interlimb coordination spatial deficits moved toward normal coordination on functional tasks. PMID:21881901

  9. Continuous variable quantum key distribution: finite-key analysis of composable security against coherent attacks.

    PubMed

    Furrer, F; Franz, T; Berta, M; Leverrier, A; Scholz, V B; Tomamichel, M; Werner, R F

    2012-09-07

    We provide a security analysis for continuous variable quantum key distribution protocols based on the transmission of two-mode squeezed vacuum states measured via homodyne detection. We employ a version of the entropic uncertainty relation for smooth entropies to give a lower bound on the number of secret bits which can be extracted from a finite number of runs of the protocol. This bound is valid under general coherent attacks, and gives rise to keys which are composably secure. For comparison, we also give a lower bound valid under the assumption of collective attacks. For both scenarios, we find positive key rates using experimental parameters reachable today.

  10. Cost-effectiveness of pediatric bilateral cochlear implantation in Spain.

    PubMed

    Pérez-Martín, Jorge; Artaso, Miguel A; Díez, Francisco J

    2017-12-01

    To determine the incremental cost-effectiveness of bilateral versus unilateral cochlear implantation for 1-year-old children suffering from bilateral sensorineural severe to profound hearing loss from the perspective of the Spanish public health system. Cost-utility analysis. We conducted a general-population survey to estimate the quality-of-life increase contributed by the second implant. We built a Markov influence diagram and evaluated it for a life-long time horizon with a 3% discount rate in the base case. The incremental cost-effectiveness ratio of simultaneous bilateral implantation with respect to unilateral implantation for 1-year-old children with severe to profound deafness is €10,323 per quality-adjusted life year (QALY). For sequential bilateral implantation, it rises to €11,733/QALY. Both options are cost-effective for the Spanish health system, whose willingness to pay is estimated at around €30,000/QALY. The probabilistic sensitivity analysis shows that the probability of bilateral implantation being cost-effective reaches 100% for that cost-effectiveness threshold. Bilateral implantation is clearly cost-effective for the population considered. If possible, it should be done simultaneously (i.e., in one surgical operation), because it is as safe and effective as sequential implantation, and saves costs for the system and for users and their families. Sequential implantation is also cost-effective for children who have received the first implant recently, but it is difficult to determine when it ceases to be so because of the lack of detailed data. These results are specific for Spain, but the model can easily be adapted to other countries. 2C. Laryngoscope, 127:2866-2872, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Bilateral temporomandibular joint dislocation with locked mandibular impaction.

    PubMed

    Hynes, Sally L; Jansen, Leigh A; Brown, D Ross; Courtemanche, Douglas J; Boyle, James C

    2012-02-01

    Bilateral anterior temporomandibular joint dislocation is very rare, with only 2 reported cases published. In the present report, we describe a healthy 25-year-old man from Haida Gwaii, in British Columbia, Canada, who was transferred to our tertiary trauma center with life-threatening complications of a bilateral anterior temporomandibular joint dislocation with locked mandibular impaction. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Final report on key comparison APMP.M.P-K13 in hydraulic gauge pressure from 50 MPa to 500 MPa

    NASA Astrophysics Data System (ADS)

    Kajikawa, Hiroaki; Kobata, Tokihiko; Yadav, Sanjay; Jian, Wu; Changpan, Tawat; Owen, Neville; Yanhua, Li; Hung, Chen-Chuan; Ginanjar, Gigin; Choi, In-Mook

    2015-01-01

    This report describes the results of a key comparison of hydraulic high-pressure standards at nine National Metrology Institutes (NMIs: NMIJ/AIST, NPLI, NMC/A*STAR, NIMT, NMIA, NIM, CMS/ITRI, KIM-LIPI, and KRISS) within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence in the pressure range from 50 MPa to 500 MPa in gauge mode. The pilot institute was the National Metrology Institute of Japan (NMIJ/AIST). All participating institutes used hydraulic pressure balances as their pressure standards. A set of pressure balance with a free-deformational piston-cylinder assembly was used as the transfer standard. Three piston-cylinder assemblies, only one at a time, were used to complete the measurements in the period from November 2010 to January 2013. Ten participants completed their measurements and reported the pressure-dependent effective areas of the transfer standard at specified pressures with the associated uncertainties. Since one of the participants withdrew its results, the measurement results of the nine participants were finally compared. The results were linked to the CCM.P-K13 reference values through the results of two linking laboratories, NMIJ/AIST and NPLI. The degrees of equivalence were evaluated by the relative deviations of the participants' results from the CCM.P-K13 key comparison reference values, and their associated combined expanded (k=2) uncertainties. The results of all the nine participating NMIs agree with the CCM.P-K13 reference values within their expanded (k=2) uncertainties in the entire pressure range from 50 MPa to 500 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Automatic temporal segment detection via bilateral long short-term memory recurrent neural networks

    NASA Astrophysics Data System (ADS)

    Sun, Bo; Cao, Siming; He, Jun; Yu, Lejun; Li, Liandong

    2017-03-01

    Constrained by the physiology, the temporal factors associated with human behavior, irrespective of facial movement or body gesture, are described by four phases: neutral, onset, apex, and offset. Although they may benefit related recognition tasks, it is not easy to accurately detect such temporal segments. An automatic temporal segment detection framework using bilateral long short-term memory recurrent neural networks (BLSTM-RNN) to learn high-level temporal-spatial features, which synthesizes the local and global temporal-spatial information more efficiently, is presented. The framework is evaluated in detail over the face and body database (FABO). The comparison shows that the proposed framework outperforms state-of-the-art methods for solving the problem of temporal segment detection.

  14. [POSTERIOR LUMBAR INTERBODY FUSION FOR DOUBLE-SEGMENTAL BILATERAL ISTHMIC LUMBAR SPONDYLOLISTHESIS].

    PubMed

    Xing, Wenhua; Huo Hongjun; Yang, Xuejun; Xiao, Yulong; Zhao, Yan; Fu, Yu; Zhu, Yong; Li, Feng; Xin, Daqi

    2015-12-01

    To explore the effectiveness of posterior lumbar interbody fusion in the treatment of double-segmental bilateral isthmic lumbar spondylolisthesis. Between February 2008 and December 2013, 17 patients with double-segmental bilateral isthmic lumbar spondylolisthesis were treated with posterior lumbar interbody fusion. There were 12 males and 5 females, with an age ranged 48-69 years (mean, 55.4 years). The disease duration ranged from 11 months to 17 years (median, 22 months). According to the Meyerding classification, 30 vertebrea were rated as degree I, 3 as degree II, and 1 as degree III. L₄,₅ was involved in 14 cases and L₃,₄ in 3 cases. The preoperative visual analogue scale (VAS) score was 8.6 ± 3.2. Cerebrospinal fluid leakage occurred in 2 cases because of intraoperative dural tear; primary healing of incision was obtained, with no operation related complication in the other patients. The patients were followed up 1-6 years (mean, 3.4 years). At last follow-up, VAS score was decreased significantly to 1.1 ± 0.4, showing significant difference when compared with preoperative score (t=7.652, P=0.008). X-ray films showed that slippage vertebral body obtained different degree of reduction, with a complete reduction rate of 85% (29/34) at 1 week after operation. All patients achieved bony union at 6-12 months (mean, 7.4 months). According to the Lenke classification, 13 cases were rated as grade A and 4 cases as grade B. No internal fixation loosening and fracture were observed during the follow-up. Intervertebral disc height was maintained, no loss of spondylolisthesis reduction was found. It can obtain satisfactory clinical result to use spinal canal decompression by posterior approach, and screw fixation for posterior fusion in treatment of double-segmental bilateral isthmic lumbar spondylolisthesis. The key points to successful operation include accurate insertion of screw, effective decompression, distraction before reduction, rational use of

  15. Comparison of unilateral versus bilateral percutaneous kyphoplasty for the treatment of patients with osteoporosis vertebral compression fracture (OVCF): a systematic review and meta-analysis.

    PubMed

    Cheng, Xing; Long, Hou-Qing; Xu, Jing-Hui; Huang, Yang-Liang; Li, Fo-Bao

    2016-11-01

    To compare the short- and long-term clinical outcomes, operation times, restoration rate, dosage of polymethylmeth-acrylate (PMMA) injected, complications and X-rays exposure frequency between unilateral and bilateral kyphoplasty approaches for the treatment of OVCF. Systematic review and meta-analysis. Randomized or non-randomized controlled trials published up to April 2015 that compared the unilateral and bilateral PKP for the treatment of OVCF were acquired by a comprehensive search in the Cochrane Controlled Trial Register, PubMed, MEDLINE, EMBASE, Web of Science, OVID. Exclusion criteria were patients with neoplastic etiology (metastasis or myeloma), infection, neural compression syndrome, invasive and degenerative disease, traumatic fracture, re-operation, neurological deficits, significant scoliosis and spinal stenosis. The main end points included: operation times, the short- and long-term postoperative Visual Analogue Scale (VAS) scores, the short-term postoperative Oswestry Disability Index (ODI), restoration rate, dosage of PMMA injected, cement leakage, X-ray exposure frequency and postoperative adjacent-level fractures. A total of 8 studies involving 428 patients were included in the meta-analysis. The mean operative time was shorter in the unilateral groups compared with the bilateral groups [P < 0.05, weighted mean difference (WMD) -19.74 (-30.56, -8.92)]. There was no significant difference in the short-term postoperative VAS scores [P > 0.05, WMD 0.03 (-0.34, 0.40)], the long-term postoperative VAS scores between them [P > 0.05, WMD 0.01 (-0.42, 0.45)] and the short-term postoperative ODI [P > 0.05, WMD -0.33 (-2.36, 1.69)] between the two groups. The unilateral approaches required significantly less dosage of PMMA than the bipedicular approaches did [P < 0.05, WMD -1.56 (-1.59, -1.16)]. The restoration rate in the bilateral groups was higher than the unilateral groups [P < 0.05, WMD -7.82 (-12.23, -3.41)]. There was no significant

  16. Ground reaction force comparison of bilateral symmetry with pneumatic resistance squat device and free weights - biomed 2009.

    PubMed

    Paulus, David C; Schilling, Brian K

    2009-01-01

    The unloading of spaceflight leads to bone and muscle atrophy, and a pneumatic resistance squat exercise countermeasure has the potential to provide optimized controllable resistance in a lightweight and compact configuration. However each end of the barbell in the proposed device is connected to a separate resistance cylinder which could lead to bilaterally asymmetric loading. Therefore, the purpose of the study is to compare the unilateral ground reaction forces (GRF) of the new squat device compared to free weights. Four previously trained men (mean +/- SD; age = 20+/-2 years, body mass = 99+/-18 kg) performed three sets of three repetitions of maximal exertion squat exercises with pneumatically controlled constant resistance and free weights each with a resistance level set to half of the body weight of each subject. Unilateral GRF data for each lifting modality at the negative to positive transition of the squat exercise was measured with a force plate under each foot. The pneumatic resistance GRF (N; mean +/- SD) was 749+/-114 on the left leg and 786+/-123 on the right leg and the free weight GRF was 786+/-114 left and 861+/-111 right resulting in a 5% difference between left and right GRF with pneumatics and 9% difference with free weights. The correlation coefficient between left and right GRF was 0.92 with pneumatics and 0.80 with free weights. Because the pneumatic device elicited more bilaterally symmetric GRF than traditional free weights, the separate resistance cylinders are an acceptable design configuration.

  17. Comparison of Dorsal Intercostal Artery Perforator Propeller Flaps and Bilateral Rotation Flaps in Reconstruction of Myelomeningocele Defects.

    PubMed

    Tenekeci, Goktekin; Basterzi, Yavuz; Unal, Sakir; Sari, Alper; Demir, Yavuz; Bagdatoglu, Celal; Tasdelen, Bahar

    2018-04-09

    Bilateral rotation flaps are considered the workhorse flaps in reconstruction of myelomeningocele defects. Since the introduction of perforator flaps in the field of reconstructive surgery, perforator flaps have been used increasingly in the reconstruction of various soft tissue defects all over the body because of their appreciated advantages. The aim of this study was to compare the complications and surgical outcomes between bilateral rotation flaps and dorsal intercostal artery perforator (DICAP) flaps in the soft tissue reconstruction of myelomeningocele defects. Between January 2005-February 2017, we studied 47 patients who underwent reconstruction of myelomeningocele defects. Patient demographics, operative data, and postoperative data were reviewed retrospectively and are included in the study. We found no statistically significant differences in patient demographics and surgical complications between these two groups; this may be due to small sample size. With regard to complications-partial flap necrosis, cerebrospinal fluid (CSF) leakage, necessity for reoperation, and wound infection-DICAP propeller flaps were clinically superior to rotation flaps. Partial flap necrosis was associated with CSF leakage and wound infection, and CSF leakage was associated with wound dehiscence. Although surgical outcomes obtained with DICAP propeller flaps were clinically superior to those obtained with rotation flaps, there was no statistically significant difference between the two patient groups. A well-designed comparative study with adequate sample size is needed. Nonetheless, we suggest using DICAP propeller flaps for reconstruction of large myelomeningocele defects.

  18. Comparison of the Josephson Voltage Standards of the DMDM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Cincar Vujovic, T.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Directorate of Measures and Precious Metals (DMDM), Belgrade, Serbia, was carried out in June 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the DMDM using its Josephson standard with its own measuring device. Option A required the DMDM to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. Since no sufficiently stable voltage could be achieved in this configuration, a digital detector was used. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 1.5 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Seizure semiology identifies patients with bilateral temporal lobe epilepsy.

    PubMed

    Loesch, Anna Mira; Feddersen, Berend; Tezer, F Irsel; Hartl, Elisabeth; Rémi, Jan; Vollmar, Christian; Noachtar, Soheyl

    2015-01-01

    Laterality in temporal lobe epilepsy is usually defined by EEG and imaging results. We investigated whether the analysis of seizure semiology including lateralizing seizure phenomena identifies bilateral independent temporal lobe seizure onset. We investigated the seizure semiology in 17 patients in whom invasive EEG-video-monitoring documented bilateral temporal seizure onset. The results were compared to 20 left and 20 right consecutive temporal lobe epilepsy (TLE) patients who were seizure free after anterior temporal lobe resection. The seizure semiology was analyzed using the semiological seizure classification with particular emphasis on the sequence of seizure phenomena over time and lateralizing seizure phenomena. Statistical analysis included chi-square test or Fisher's exact test. Bitemporal lobe epilepsy patients had more frequently different seizure semiology (100% vs. 40%; p<0.001) and significantly more often lateralizing seizure phenomena pointing to bilateral seizure onset compared to patients with unilateral TLE (67% vs. 11%; p<0.001). The sensitivity of identical vs. different seizure semiology for the identification of bilateral TLE was high (100%) with a specificity of 60%. Lateralizing seizure phenomena had a low sensitivity (59%) but a high specificity (89%). The combination of lateralizing seizure phenomena and different seizure semiology showed a high specificity (94%) but a low sensitivity (59%). The analysis of seizure semiology including lateralizing seizure phenomena adds important clinical information to identify patients with bilateral TLE. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Key Competencies. Second Edition.

    ERIC Educational Resources Information Center

    Haworth, David; Browne, Geoff

    Key competencies (or generic skills) have been specified in four sources: Further Education Unit (FEU), United Kingdom (1987); Finn Report (1991) and Mayer Committee (1992), Australia; U.S. Labor Secretary's Commission on Achieving Necessary Skills (SCANS) (June 1991); and Butterworth and Lovell (1983), New South Wales. A comparison of the four…

  1. [Epithelioid bilateral ovarian leiomyosarcoma: a study].

    PubMed

    Khabir, Abdelmajid; Boudawara, Tahia; Ayadi, Lobna; Kharrat, Maha; Kharrat, Madiha; Beyrouti, Issam; Jlidi, Rachid

    2003-02-01

    Primary ovarian leiomyosarcoma is extremely rare and generally affects post menopausal women. It is usually unilateral and more than 10 cm in diameter. Its histogenesis is not clear its prognosis seems to be improved by radical surgery and adjuvant therapy. We report a case of a 54 year-old, nulliparous, post menopausal woman who had abdominal distention. Physical examination revealed a large pelvi-abdominal mass. The excision of tumor with bilateral salpingo-oophorectomy and hysterectomy was carried out. A diagnosis of bilateral ovarian epithelioid leiomyosarcoma was made on pathological examination with immunohistochemistry. Adjuvant chemotherapy was given. After 3 months of follow up, abdominal sonography revealed a peritoneal recurrent tumor with hepatic metastasis. Our objectives are to discuss the histopathological features and the prognosis of this tumor.

  2. BILATERAL HYDRONEPHROSIS IN A SUGAR GLIDER (PETAURUS BREVICEPS).

    PubMed

    Cusack, Lara; Schnellbacher, Rodney; Howerth, Elizabeth W; Jiménez, David A; Mayer, Joerg; Divers, Stephen

    2016-09-01

    An adult, intact male sugar glider ( Petaurus breviceps ) presented for acute caudal abdominal swelling. Treatment by the referring veterinarian included aspiration of urine from the swelling. On physical examination, mild depression, pale mucus membranes, and caudal abdominal swelling were noted. Focused ultrasonographic assessment revealed a fluid-filled caudal abdominal structure and subjective bladder wall thickening. The following day, the sugar glider was severely depressed. Hematology results included hypoglycemia, hyperkalemia, hyponatremia, and azotemia. Ultrasonography revealed bilateral hydronephrosis and hydroureter. Despite supportive care, the animal died. Postmortem examination confirmed bilateral ureteral dilation, renal petechial hemorrhage, and dilation of the right renal pelvis. Submucosal edema, hemorrhage, and lymphoplasmacytic infiltration of the urinary bladder, ureters, and renal pelvises were noted. Hyperplasia of the urinary bladder and ureteral epithelium, coupled with inflammation, may have caused functional obstruction leading to bilateral hydronephrosis and hydroureter. This is the first reported case of hydronephrosis in a marsupial.

  3. Bilateral Posterior Scleritis Associated with Giant Cell Arteritis: A Case Report.

    PubMed

    Erdogan, Mehmet; Sayin, Nihat; Yıldız Ekinci, Dilbade; Bayramoglu, Sadik

    2017-09-15

    To report a case of bilateral posterior scleritis associated with giant cell arteritis Case Report: A 62-year-old female patient presented with bilateral progressive vision loss was diagnosed with bilateral posterior scleritis. According to clinical signs and symptoms and laboratory testing, Giant cell arteritis was also diagnosed. Within 8 weeks of the corticosteroid treatment, the serous retinal detachments completely resolved and choroidal thickness decreased in both eyes. Visual acuity increased, and the symtoms related to Giant cell arteritis improved. Posterior scleritis is an inflammatory disease that may be associated with many autoimmune systemic diseases. GCA should be thought of particularly in patients over the age of 50 with bilateral involvement, and a relevant detailed history should be obtained for early and correct diagnosis and treatment.

  4. [Metachronous Bilateral Hemothorax Due to Reverse Chance Type Thoracic Fracture].

    PubMed

    Fukada, Takehisa; Morita, Katsuhiko; Ueki, Takayuki; Hanaoka, Nobuharu

    2017-06-01

    Metachronous bilateral hemothorax due to reverse Chance type thoracic fracture is very rare. In this case, we experienced a case of metachronous bilateral hemothorax, triggered by a thoracic fracture in which the anterior component of the spine collapsed, so-called reverse Chance type thoracic fracture. An 83-year-old woman with spinal kyphosis traumatically injured thoracic spine burst fracture, and bone fragments appeared on both sides of the destroyed vertebra. After injury, the left hemothorax also appeared, followed by the right hemothorax causing hemorrhagic shock. In thoracic destructive anterior fracture, we should consider the possibility of metachronous bilateral hemothorax.

  5. Comparison of peripapillary retinal nerve fiber layer loss and visual outcome in fellow eyes following sequential bilateral non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Dotan, Gad; Kesler, Anat; Naftaliev, Elvira; Skarf, Barry

    2015-05-01

    To report on the correlation of structural damage to the axons of the optic nerve and visual outcome following bilateral non-arteritic anterior ischemic optic neuropathy. A retrospective review of the medical records of 25 patients with bilateral sequential non-arteritic anterior ischemic optic neuropathy was performed. Outcome measures were peripapillary retinal nerve fiber layer thickness measured with the Stratus optical coherence tomography scanner, visual acuity and visual field loss. Median peripapillary retinal nerve fiber layer (RNFL) thickness, mean deviation (MD) of visual field, and visual acuity of initially involved NAION eyes (54.00 µm, -17.77 decibels (dB), 0.4, respectively) were comparable to the same parameters measured following development of second NAION event in the other eye (53.70 µm, p = 0.740; -16.83 dB, p = 0.692; 0.4, p = 0.942, respectively). In patients with bilateral NAION, there was a significant correlation of peripapillary RNFL thickness (r = 0.583, p = 0.002) and MD of the visual field (r = 0.457, p = 0.042) for the pairs of affected eyes, whereas a poor correlation was found in visual acuity of these eyes (r = 0.279, p = 0.176). Peripapillary RNFL thickness following NAION was positively correlated with MD of visual field (r = 0.312, p = 0.043) and negatively correlated with logMAR visual acuity (r = -0.365, p = 0.009). In patients who experience bilateral NAION, the magnitude of RNFL loss is similar in each eye. There is a greater similarity in visual field loss than in visual acuity between the two affected eyes with NAION of the same individual.

  6. Final report on the key comparison, CCM.P-K15 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Arai, Kenta; Bergoglio, Mercede; Fedchak, James A.; Jousten, Karl; Hong, Seung Soo; Torres Guzman, Jorge

    2017-01-01

    The comparison CCM.P-K15 is a key comparison in pressure involving six laboratories in three regional metrological organizations (RMO). The measurand of the comparison is the accommodation coefficient of two spinning rotating gauge characterized in nitrogen from 0.1 mPa up to 1.0 Pa. The two transfer standards were circulated from November 2009 until March 2011. The circulation consisted of three loops, one for each RMO, and a new calibration by the pilot be-tween each loop. The stability of one of the transfer standards was poor and was worse than expected based on the previous history of the transfer standard while the other transfer standard demonstrated good stability while circulated in Europe and America and a fair stability while circulated in Asia. All the participants demonstrated equivalence to the definition of pressure in their respective primary standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. [The place of surgery in bilateral sequelae bronchiectasis].

    PubMed

    Issoufou, I; Rabiou, S; Belliraj, L; Ammor, F Z; Harmouchi, H; Diarra, A S; Lakranbi, M; Serraj, M; Ouadnouni, Y; Smahi, M

    2017-06-01

    The aim of our study is to report our surgery results in bilateral sequelae bronchiectasis and to assess its impact on the life quality of our patients. This is a retrospective descriptive study in thoracic surgery department of Teaching Hospital Hassan II of Fez in Morocco. It involved all patients with bilateral bronchiectasis which is predominant on a few lobes or segments (localized) and who underwent surgery during the period 2010-2015. The epidemiological, clinical and paraclinical data, the surgery results, the evolution and the impact on life quality were assessed. From a total of 47 patients with bilateral bronchiectasis, 13 were operated, thus a frequency of 27.6%. The average age was 32years, ranging from 15 to 54years. Women were in majority (61.5%) representing a sex ratio of 1.6. The association of chronic bronchorrhea and hemoptysis was the main reason of medical consultation in 46.16%, followed by isolated chronic bronchorrhea in 38.46%. Surgical resection involved the left side in 61.5% of cases. The left lower lobectomy was the most accomplished gesture. An improvement in symptoms was found in 11 patients (84.6%) as a decrease in bronchorrhea, hemoptysis episodes and decreasing use of antibiotics. Bilateral bronchiectasis surgery can be performed with acceptable morbidity and mortality in well-selected patients with an improvement in symptoms. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Bilateral chondrosarcoma of the jugular foramen: literature review and personal experience.

    PubMed

    Zanoletti, Elisabetta; Faccioli, Chiara; Cazzador, Diego; Mazzoni, Antonio; Martini, Alessandro

    2015-10-01

    Chondrosarcomas (CS) are slow-growing malignant cartilaginous tumors with locally invasive behavior. They account for only 0.15% head and neck neoplasia. There have been no reports in the management of bilateral skull base CS in the literature to date. The synchronous presentation of bilateral CS of the jugular foramen (JF) was diagnosed in a 22-year-old woman with right abducens nerve palsy. Once evaluated the collateral intracranial venous discharge, the lesions were removed in two surgical stages through a bilateral petro-occipital trans-sigmoid (POTS) approach performing a bilateral closure of sigmoid sinus. The patient is disease free 15 years after surgery. No complications occurred. Diplopia improved after excision of the tumor on the right side. A review of relevant English literature was performed. The POTS approach to the JF proved to be safe and effective. Staged radical surgery alone, assessing intracranial venous flow at all stages of surgery, was a valid strategy for bilateral CS, achieving long-term disease control, avoiding early adjuvant radiotherapy, and carrying no complications.

  9. Temporal lobe developmental malformations and epilepsy: dual pathology and bilateral hippocampal abnormalities.

    PubMed

    Ho, S S; Kuzniecky, R I; Gilliam, F; Faught, E; Morawetz, R

    1998-03-01

    Temporal lobe developmental malformations (TLDM) with focal cortical dysplasia and balloon cells may coexist with mesial temporal sclerosis. The true incidence of this dual pathology is unknown. Our aim was to assess the frequency of amygdala (AM)-hippocampal abnormality in a homogeneous population with this specific developmental malformation. MRI-based volumetry of the AM and hippocampal formation (HF) in 30 patients with unilateral TLDM and intractable partial epilepsy was performed. A volume normalization process defined a normal range of HF and AM volumes in control subjects, and enabled the detection of bilateral volume loss. Normalized volumes detected HF atrophy in 26 patients (nine unilateral and 17 bilateral) and AM atrophy in 18 patients (three unilateral and 15 bilateral). Visual analysis detected unilateral HF abnormality in 21 patients and bilateral abnormality in two. When compared with a group of patients with temporal lobe epilepsy and pure hippocampal sclerosis (N = 92), where volumetry revealed bilateral HF atrophy in 18%, a significant difference in the frequency of bilateral HF atrophy was found (p < 0.0001). Dual pathology is frequent in patients with TLDM (87%), and the AM-HF abnormality is often bilateral (57%). Our data suggest that more widespread and potentially epileptogenic lesions coexist with visibly detectable unilateral TLDM. This has implications for the selection of patients for temporal lobe surgery and may influence surgical strategies.

  10. Motor correlates of models of secondary bilateral synchrony and multiple epileptic foci.

    PubMed

    Jiruska, Premysl; Proks, Jan; Otáhal, Jakub; Mares, Pavel

    2007-10-01

    Bilateral synchronous epileptiform discharges registered in patients with partial epilepsies may be generated by different pathophysiological mechanisms. Differentiation between underlying mechanisms is often crucial for correct diagnosis and adequate treatment in clinical epileptology. The aim of this study was to model in rats two possible mechanisms--secondary bilateral sychrony and interaction between multiple epilepic foci. Furthermore, to describe in detail semiology, laterality and differences in motor phenomena. Secondary bilateral synchrony was modeled by unilateral topical application of bicuculline methiodide (BMI) over the sensorimotor cortex. Bilateral symmetric application of BMI was used as a model of multiple epileptic foci. Electrographic and behavioural phenomena were recorded for 1h following the application of BMI. Electroencephalogram in both groups was characterized by presence of bilateral synchronous discharges. Myoclonic and clonic seizures involving forelimb and head muscles represented the most common motor seizure pattern in both groups. Significant differences were found in the laterality of motor phenomena. Motor seizures in unilateral foci always started in the contralateral limbs whereas symmetrical foci exhibited bilateral independent onset of convulsions. Similar lateralization was observed in interictal motor phenomena (myoclonic jerks). An important influence of posture on epileptic motor phenomena was demonstrated. Active or passive changes in animal posture (verticalization to bipedal posture) caused conversion from unilateral myoclonic jerks or clonic seizures to bilaterally synchronous (generalized) motor phenomena in both groups.

  11. Cochlear Implantation after Bilateral Transverse Temporal Bone Fractures

    PubMed Central

    Shin, Jong-Heon; Park, SooChan; Baek, Sam-Hyun

    2008-01-01

    Patients deafened by a severe head injury are rarely encountered. We report a case of a 65-yr-old man with bilateral transverse temporal bone fractures due to head injury. He underwent cochlear implant and achieved a satisfactory auditory rehabilitation. Imaging studies of temporal bone before performing a cochlear implantation provide important information on a patient with bilateral temporal bone fractures. Cochlear implantations with careful planning in such a patient may be a very effective method for aural rehabilitation. PMID:19434252

  12. Bilateral tension pneumothorax resulting from a bicycle-to-bicycle collision

    PubMed Central

    Edwin, Frank; Sereboe, Lawrence; Tettey, Mark Mawutor; Aniteye, Ernest; Bankah, Patrick; Frimpong-Boateng, Kwabena

    2009-01-01

    Bilateral tension pneumothorax occurring as a result of recreational activity is exceedingly rare. A 10-year-old boy with no previous respiratory symptoms was involved in a bicycle-to-bicycle collision during play. He was the only one hurt. A few hours later, he was rushed to the general casualty unit of the emergency department of our institution with respiratory distress, diminished bilateral chest excursions and diminished breath sounds. The correct diagnosis was made after a chest radiograph was obtained in the course of resuscitation at the casualty unit. Pleural space needle decompression was suggestive of tension only on the right. Bilateral tube thoracostomies provided effective relief. He was discharged from hospital after a week in excellent health. This case illustrates the need for children to have safety instruction to reduce the risks of recreational bicycling. Chest radiography may be needed to establish the diagnosis of bilateral tension pneumothorax. Needle thoracostomy decompression is not always effective. PMID:22148075

  13. Bilateral tension pneumothorax resulting from a bicycle-to-bicycle collision.

    PubMed

    Edwin, Frank; Sereboe, Lawrence; Tettey, Mark Mawutor; Aniteye, Ernest; Bankah, Patrick; Frimpong-Boateng, Kwabena

    2009-01-01

    Bilateral tension pneumothorax occurring as a result of recreational activity is exceedingly rare. A 10-year-old boy with no previous respiratory symptoms was involved in a bicycle-to-bicycle collision during play. He was the only one hurt. A few hours later, he was rushed to the general casualty unit of the emergency department of our institution with respiratory distress, diminished bilateral chest excursions and diminished breath sounds. The correct diagnosis was made after a chest radiograph was obtained in the course of resuscitation at the casualty unit. Pleural space needle decompression was suggestive of tension only on the right. Bilateral tube thoracostomies provided effective relief. He was discharged from hospital after a week in excellent health. This case illustrates the need for children to have safety instruction to reduce the risks of recreational bicycling. Chest radiography may be needed to establish the diagnosis of bilateral tension pneumothorax. Needle thoracostomy decompression is not always effective.

  14. Note: Unshielded bilateral magnetoencephalography system using two-dimensional gradiometers

    NASA Astrophysics Data System (ADS)

    Seki, Yusuke; Kandori, Akihiko; Ogata, Kuniomi; Miyashita, Tsuyoshi; Kumagai, Yukio; Ohnuma, Mitsuru; Konaka, Kuni; Naritomi, Hiroaki

    2010-09-01

    Magnetoencephalography (MEG) noninvasively measures neuronal activity with high temporal resolution. The aim of this study was to develop a new type of MEG system that can measure bilateral MEG waveforms without a magnetically shielded room, which is an obstacle to reducing both the cost and size of an MEG system. An unshielded bilateral MEG system was developed using four two-dimensional (2D) gradiometers and two symmetric cryostats. The 2D gradiometer, which is based on a low-Tc superconducting quantum interference device and wire-wound pickup coil detects a magnetic-field gradient in two orthogonal directions, or ∂/∂x(∂2Bz/∂z2), and reduces environmental magnetic-field noise by more than 50 dB. The cryostats can be symmetrically positioned in three directions: vertical, horizontal, and rotational. This makes it possible to detect bilateral neuronal activity in the cerebral cortex simultaneously. Bilateral auditory-evoked fields (AEF) of 18 elderly subjects were measured in an unshielded hospital environment using the MEG system. As a result, both the ipsilateral and the contralateral AEF component N100m, which is the magnetic counterpart of electric N100 in electroencephalography and appears about 100 ms after the onset of an auditory stimulus, were successfully detected for all the subjects. Moreover, the ipsilateral P50m and the contralateral P50m were also detected for 12 (67%) and 16 (89%) subjects, respectively. Experimental results demonstrate that the unshielded bilateral MEG system can detect MEG waveforms, which are associated with brain dysfunction such as epilepsy, Alzheimer's disease, and Down syndrome.

  15. Multilateral, regional and bilateral energy trade governance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leal-Arcas, Rafael; Grasso, Costantino; Rios, Juan Alemany

    The current international energy trade governance system is fragmented and multi-layered. Streamlining it for greater legal cohesiveness and international political and economic cooperation would promote global energy security. The current article explores three levels of energy trade governance: multilateral, regional and bilateral. Most energy-rich countries are part of the multilateral trading system, which is institutionalized by the World Trade Organization (WTO). The article analyzes the multilateral energy trade governance system by focusing on the WTO and energy transportation issues. Regionally, the article focuses on five major regional agreements and their energy-related aspects and examines the various causes that explain themore » proliferation of regional trade agreements, their compatibility with WTO law, and then provides several examples of regional energy trade governance throughout the world. When it comes to bilateral energy trade governance, this article only addresses the European Union’s (EU) bilateral energy trade relations. The article explores ways in which gaps could be filled and overlaps eliminated whilst remaining true to the high-level normative framework, concentrating on those measures that would enhance EU energy security.« less

  16. [Bilateral traumatic patella fracture: a case report].

    PubMed

    Cırpar, Meriç; Türker, Mehmet; Aslan, Arif; Yalçınozan, Mehmet

    2011-08-01

    Patellar fractures are uncommon injuries and account for approximately 1% of all fractures. In this article, a 35-year-old male patient who sustained a collision deceleration accident with bilateral comminuted transverse patellar fractures is presented. For this patient, open reduction and internal fixation with tension band technique, using two Kirschner wires and cerclage wire was applied for both fractures. At the first postoperative day, isometric quadriceps and active range of motion exercises were begun and the patient was allowed to walk full weight bearing with two crutches while both extremities were immobilized in a hinged brace allowing maximum 30 degrees of flexion. At postoperative fourth week brace immobilization was terminated. However, the patient was advised to use crutches for two weeks more to prevent any complications that may arise during walking because of the bilaterally of the injury. At six weeks solid union was achieved. During the last visit at postoperative second year, the patient had no complaints and the range of motion was full. In this paper a case of bilateral patella fractures is presented as a consequence of a dashboard injury, and the pathomechanical and therapeutical aspects of such an injury is discussed.

  17. Refractory thoracic endometriosis syndrome with bilateral hemothorax.

    PubMed

    Lua, Lannah L; Tran, Kevin; Desai, Jyoti

    2017-07-01

    Thoracic endometriosis syndrome (TES) is a rare disorder presenting with catamenial pneumothorax, hemothorax, hemoptysis or pulmonary nodules. Bilateral involvement is uncommon, and only a very few cases have been reported in the literature. We report a case of bilateral catamenial hemothorax in a patient with recurrent thoracic endometriosis. Despite multiple surgical interventions, the patient continued to develop hemopneumothorax coinciding with menses. Remission was finally achieved with the addition of gonadotropin-releasing hormone agonist, highlighting the effectiveness of postoperative adjuvant hormone therapy and supporting a combined surgical and medical approach in the treatment of TES in patients who desire future fertility. © 2017 Japan Society of Obstetrics and Gynecology.

  18. Pediatric Bilateral Blue Laser Pointer-Induced Maculopathy

    PubMed Central

    Raevis, Joseph; Shrier, Eric

    2017-01-01

    Background We report the first case of pediatric bilateral blue laser pointer maculopathy with complete resolution of visual symptoms. Case A 12-year-old boy presented with bilateral decreased visual acuity and central scotomata after blue laser pointer exposure. He was treated with a Medrol Dosepak and topical nonsteroidal anti-inflammatory drug (NSAID), with gradual visual acuity improved from 20/40 OU to 20/20 OU over 22 weeks, but with persistent evidence of outer retinal layer disruption from the external limiting membrane to the interdigitation zone. Conclusion Oral steroids and topical NSAIDs may be effective in improving visual outcomes in laser pointer maculopathy in the pediatric population. PMID:28611647

  19. Comparison of visual outcomes after bilateral implantation of extended range of vision and trifocal intraocular lenses.

    PubMed

    Ruiz-Mesa, Ramón; Abengózar-Vela, Antonio; Aramburu, Ana; Ruiz-Santos, María

    2017-06-26

    To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal. Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire. The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05). Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.

  20. A comparative study of standard intensity-modulated radiotherapy and RapidArc planning techniques for ipsilateral and bilateral head and neck irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pursley, Jennifer, E-mail: jpursley@mgh.harvard.edu; Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA; Damato, Antonio L.

    The purpose of this study was to investigate class solutions using RapidArc volumetric-modulated arc therapy (VMAT) planning for ipsilateral and bilateral head and neck (H&N) irradiation, and to compare dosimetric results with intensity-modulated radiotherapy (IMRT) plans. A total of 14 patients who received ipsilateral and 10 patients who received bilateral head and neck irradiation were retrospectively replanned with several volumetric-modulated arc therapy techniques. For ipsilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the contralateral parotid, two 260° or 270° arcs, and two 210° arcs. For bilateral neck irradiation, themore » volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the shoulders, and 3 arcs. All patients had a sliding-window-delivery intensity-modulated radiotherapy plan that was used as the benchmark for dosimetric comparison. For ipsilateral neck irradiation, a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid was dosimetrically comparable to intensity-modulated radiotherapy, with improved conformity (conformity index = 1.22 vs 1.36, p < 0.04) and lower contralateral parotid mean dose (5.6 vs 6.8 Gy, p < 0.03). For bilateral neck irradiation, 3-arc volumetric-modulated arc therapy techniques were dosimetrically comparable to intensity-modulated radiotherapy while also avoiding irradiation through the shoulders. All volumetric-modulated arc therapy techniques required fewer monitor units than sliding-window intensity-modulated radiotherapy to deliver treatment, with an average reduction of 35% for ipsilateral plans and 67% for bilateral plans. Thus, for ipsilateral head and neck irradiation a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid is

  1. A comparative study of standard intensity-modulated radiotherapy and RapidArc planning techniques for ipsilateral and bilateral head and neck irradiation.

    PubMed

    Pursley, Jennifer; Damato, Antonio L; Czerminska, Maria A; Margalit, Danielle N; Sher, David J; Tishler, Roy B

    2017-01-01

    The purpose of this study was to investigate class solutions using RapidArc volumetric-modulated arc therapy (VMAT) planning for ipsilateral and bilateral head and neck (H&N) irradiation, and to compare dosimetric results with intensity-modulated radiotherapy (IMRT) plans. A total of 14 patients who received ipsilateral and 10 patients who received bilateral head and neck irradiation were retrospectively replanned with several volumetric-modulated arc therapy techniques. For ipsilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the contralateral parotid, two 260° or 270° arcs, and two 210° arcs. For bilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the shoulders, and 3 arcs. All patients had a sliding-window-delivery intensity-modulated radiotherapy plan that was used as the benchmark for dosimetric comparison. For ipsilateral neck irradiation, a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid was dosimetrically comparable to intensity-modulated radiotherapy, with improved conformity (conformity index = 1.22 vs 1.36, p < 0.04) and lower contralateral parotid mean dose (5.6 vs 6.8Gy, p < 0.03). For bilateral neck irradiation, 3-arc volumetric-modulated arc therapy techniques were dosimetrically comparable to intensity-modulated radiotherapy while also avoiding irradiation through the shoulders. All volumetric-modulated arc therapy techniques required fewer monitor units than sliding-window intensity-modulated radiotherapy to deliver treatment, with an average reduction of 35% for ipsilateral plans and 67% for bilateral plans. Thus, for ipsilateral head and neck irradiation a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid is

  2. Bilateral Bell palsy as a presenting sign of preeclampsia.

    PubMed

    Vogell, Alison; Boelig, Rupsa C; Skora, Joanna; Baxter, Jason K

    2014-08-01

    Bell palsy is a facial nerve neuropathy that is a rare disorder but occurs at higher frequency in pregnancy. Almost 30% of cases are associated with preeclampsia or gestational hypertension. Bilateral Bell palsy occurs in only 0.3%-2.0% of cases of facial paralysis, has a poorer prognosis for recovery, and may be associated with a systemic disorder. We describe a case of a 24-year-old primigravid woman with a twin gestation at 35 weeks diagnosed initially with bilateral facial palsy and subsequently with preeclampsia. She then developed partial hemolysis, elevated liver enzymes, and low platelet count syndrome, prompting the diagnosis of severe preeclampsia, and was delivered. Bilateral facial palsy is a rare entity in pregnancy that may be the first sign of preeclampsia and suggests increased severity of disease, warranting close monitoring.

  3. Adenocarcinoma of the ethmoid following radiotherapy for bilateral retinoblastoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rowe, L.D.; Lane, R.; Snow, J.B. Jr.

    1980-01-01

    Adenocarcinoma of the ethmoid sinus is rare, representing only 4 to 8% of malignancies of the paranasal sinuses. An extraordinary case of papillary adenocarcinoma of the ethmoid sinus arising 30 years following high-dose radiotherapy for bilateral retinoblastoma is presented. Second fatal mesenchymal and epithelial primaries have been described in 8.5% of patients with bilateral retinoblastomas previously treated with radiotherapy; however, papillary adenocarcinoma arising within the paranasal sinuses has not been reported. Aggressive treatment including partial maxillectomy, radical pansinusectomy, radical neck dissection followed by regional radiotherapy and systemic chemotherapy failed to prevent the development of fatal hepatic metastases. The high incidencemore » of second fatal primary neoplasms in patients with bilateral retinoblastomas receiving radiation suggests an innate susceptibility that may add to the risk of radiotherapy.« less

  4. Bilateral Video-Assisted Thoracoscopic Surgery Resection for Multiple Mediastinal Myelolipoma: Report of a Case

    PubMed Central

    Kohno, Tadasu; Mun, Mingyon; Yoshiya, Tomoharu

    2014-01-01

    Myelolipoma in the mediastinum is an extremely rare entity. In this report, we present the case of a 79-year-old asymptomatic man who had three bilateral paravertebral mediastinal tumors. The three tumors were resected simultaneously using bilateral three-port video-assisted thoracoscopic surgery (VATS). There has been no evidence of recurrence within four years after the operation. Multiple bilateral mediastinal myelolipomas are extremely rare. There are no reports in the English literature of multiple bilateral thoracic myelolipomas that were resected simultaneously using bilateral VATS. We also present characteristic features of myelolipomas, which are helpful for diagnosis. PMID:24782978

  5. Immediately sequential bilateral cataract surgery: advantages and disadvantages.

    PubMed

    Singh, Ranjodh; Dohlman, Thomas H; Sun, Grace

    2017-01-01

    The number of cataract surgeries performed globally will continue to rise to meet the needs of an aging population. This increased demand will require healthcare systems and providers to find new surgical efficiencies while maintaining excellent surgical outcomes. Immediately sequential bilateral cataract surgery (ISBCS) has been proposed as a solution and is increasingly being performed worldwide. The purpose of this review is to discuss the advantages and disadvantages of ISBCS. When appropriate patient selection occurs and guidelines are followed, ISBCS is comparable with delayed sequential bilateral cataract surgery in long-term patient satisfaction, visual acuity and complication rates. In addition, the risk of bilateral postoperative endophthalmitis and concerns of poorer refractive outcomes have not been supported by the literature. ISBCS is cost-effective for the patient, healthcare payors and society, but current reimbursement models in many countries create significant financial barriers for facilities and surgeons. As demand for cataract surgery rises worldwide, ISBCS will become increasingly important as an alternative to delayed sequential bilateral cataract surgery. Advantages include potentially decreased wait times for surgery, patient convenience and cost savings for healthcare payors. Although they are comparable in visual acuity and complication rates, hurdles that prevent wide adoption include liability concerns as ISBCS is not an established standard of care, economic constraints for facilities and surgeons and inability to fine-tune intraocular lens selection in the second eye. Given these considerations, an open discussion regarding the advantages and disadvantages of ISBCS is important for appropriate patient selection.

  6. Effects of virtual reality-based bilateral upper-extremity training on brain activity in post-stroke patients.

    PubMed

    Lee, Su-Hyun; Kim, Yu-Mi; Lee, Byoung-Hee

    2015-07-01

    [Purpose] This study investigated the therapeutic effects of virtual reality-based bilateral upper-extremity training on brain activity in patients with stroke. [Subjects and Methods] Eighteen chronic stroke patients were divided into two groups: the virtual reality-based bilateral upper-extremity training group (n = 10) and the bilateral upper-limb training group (n = 8). The virtual reality-based bilateral upper-extremity training group performed bilateral upper-extremity exercises in a virtual reality environment, while the bilateral upper-limb training group performed only bilateral upper-extremity exercise. All training was conducted 30 minutes per day, three times per week for six weeks, followed by brain activity evaluation. [Results] Electroencephalography showed significant increases in concentration in the frontopolar 2 and frontal 4 areas, and significant increases in brain activity in the frontopolar 1 and frontal 3 areas in the virtual reality-based bilateral upper-extremity training group. [Conclusion] Virtual reality-based bilateral upper-extremity training can improve the brain activity of stroke patients. Thus, virtual reality-based bilateral upper-extremity training is feasible and beneficial for improving brain activation in stroke patients.

  7. Outcomes of unilateral and bilateral total knee arthroplasty in 238,373 patients

    PubMed Central

    Molodianovitsh, Katy; Dragan, Alina; Zhu, Naisu; Webster, Greg; Masri, Bas; Schemitsch, Emil; Dunbar, Michael

    2016-01-01

    Background and purpose — There is no consensus about the outcome of simultaneous vs. staged bilateral total knee arthroplasty (TKA). We examined this issue by analyzing 238,373 patients. Patients and methods — Demographic, clinical, and outcome data were evaluated for TKA patients (unilateral: 206,771; simultaneous bilateral: 6,349; staged bilateral: 25,253) from the Canadian Hospital Morbidity Database for fiscal years 2006–2007 to 2012–2013. Outcomes were adjusted for age, sex, comorbidities, and hospital TKA volume. Results — Simultaneous bilateral TKA patients were younger than staged bilateral TKA patients (median 64 years vs. 66 years), were more likely to be male (41% vs. 39%), and had a lower frequency of having ≥1 comorbid condition (2.9% vs. 4.2%). They also had a higher frequency of blood transfusions (41% vs. 19%), a shorter median length of stay (6 days vs. 8 days), a higher frequency of transfer to a rehabilitation facility (46% vs. 9%), and a lower frequency of knee infection (0.5% vs. 0.9%) than staged bilateral TKA patients, but they had higher rate of cardiac complications within 90 days (2.0% vs. 1.7%). Simultaneous patients had higher in-hospital mortality compared to the second TKA in staged patients (0.16% vs. 0.06%), but they had similar rates of in-hospital mortality compared to unilateral patients (0.16% vs. 0.14%). The cumulative 3-year revision rate was highest in the unilateral group (2.3%), but it was similar in the staged and simultaneous bilateral groups (1.4%). Interpretation — We found important differences between the outcomes of simultaneous and staged bilateral TKA. Further clarification of outcomes would be best determined in an adequately powered randomized trial, which would remove the selection bias inherent in this retrospective study design. PMID:27167849

  8. A patient with bilateral facial palsy associated with hypertension and chickenpox: learning points.

    PubMed

    Al-Abadi, Eslam; Milford, David V; Smith, Martin

    2010-11-26

    Bilateral facial nerve paralysis is an uncommon presentation and even more so in children. There are reports of different causes of bilateral facial nerve palsy. It is well-established that hypertension and chickenpox causes unilateral facial paralysis and the importance of checking the blood pressure in children with facial nerve paralysis cannot be stressed enough. The authors report a boy with bilateral facial nerve paralysis in association with hypertension and having recently recovered from chickenpox. The authors review aspects of bilateral facial nerve paralysis as well as hypertension and chickenpox causing facial nerve paralysis.

  9. KEY COMPARISON Update of the BIPM.RI(II)-K1.Tc-99m comparison of activity measurements for the radionuclide 99mTc to include new results for the LNE-LNHB and the NPL

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Moune, M.; Johansson, L.; Keightley, J.

    2010-01-01

    In 2007 and 2008 respectively, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of 99mTc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNHB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Lifespan development of the bilateral deficit in a simple reaction time task.

    PubMed

    Vieluf, Solveig; Aschersleben, Gisa; Panzer, Stefan

    2017-04-01

    Performing an action at a maximum speed or with a maximum strength simultaneously with two limbs leads to a lower performance than the sum of unimanual performances. This phenomenon is known as bilateral deficit. There is some evidence that the bilateral deficit changes over the lifespan, in a way that children and older adults show lower deficits than young adults. Inverse developmental changes of childrens' and older adults' brain structures connecting both hemispheres, i.e., the corpus callosum, might importantly contribute to this phenomenon. The seemingly similar developments have been observed with different experimental protocols in the different age groups, respectively. To test for similarities and differences in changes of the bilateral deficit at critical periods of the lifespan development of bimanual actions, children, young adults, and older adults performed a simple reaction time task uni- and bimanually. Reaction times and the resulting bilateral deficit, as well as reaction time variability were analyzed. As expected, reaction times were different for the young adults between the uni- and the bimanual task. Children and older adults performed both conditions with similar reaction times. However, a difference in the direction of the %bilateral deficit occurred between the two age groups. The findings demonstrated an absence of the bilateral deficit for children, but not for younger and older adults.

  11. SHORT COMMUNICATION: Comparison between two mobile absolute gravimeters: optical versus atomic interferometers

    NASA Astrophysics Data System (ADS)

    Merlet, S.; Bodart, Q.; Malossi, N.; Landragin, A.; Pereira Dos Santos, F.; Gitlein, O.; Timmen, L.

    2010-08-01

    We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atom gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participate in the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of (4.3 ± 6.4) µGal.

  12. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    PubMed

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  13. Speech recognition for bilaterally asymmetric and symmetric hearing aid microphone modes in simulated classroom environments.

    PubMed

    Ricketts, Todd A; Picou, Erin M

    2013-09-01

    This study aimed to evaluate the potential utility of asymmetrical and symmetrical directional hearing aid fittings for school-age children in simulated classroom environments. This study also aimed to evaluate speech recognition performance of children with normal hearing in the same listening environments. Two groups of school-age children 11 to 17 years of age participated in this study. Twenty participants had normal hearing, and 29 participants had sensorineural hearing loss. Participants with hearing loss were fitted with behind-the-ear hearing aids with clinically appropriate venting and were tested in 3 hearing aid configurations: bilateral omnidirectional, bilateral directional, and asymmetrical directional microphones. Speech recognition testing was completed in each microphone configuration in 3 environments: Talker-Front, Talker-Back, and Question-Answer situations. During testing, the location of the speech signal changed, but participants were always seated in a noisy, moderately reverberant classroom-like room. For all conditions, results revealed expected effects of directional microphones on speech recognition performance. When the signal of interest was in front of the listener, bilateral directional microphone was best, and when the signal of interest was behind the listener, bilateral omnidirectional microphone was best. Performance with asymmetric directional microphones was between the 2 symmetrical conditions. The magnitudes of directional benefits and decrements were not significantly correlated. In comparison with their peers with normal hearing, children with hearing loss performed similarly to their peers with normal hearing when fitted with directional microphones and the speech was from the front. In contrast, children with normal hearing still outperformed children with hearing loss if the speech originated from behind, even when the children were fitted with the optimal hearing aid microphone mode for the situation. Bilateral

  14. Bilateral ureteric stones: an unusual cause of acute kidney injury.

    PubMed

    Sumner, Daniel; Rehnberg, Lucas; Kler, Aaron

    2016-03-30

    A 49-year-old man presented to the accident and emergency department, with a short history of vague abdominal pain, abdominal distension and two episodes of frank haematuria. A plain chest film showed dilated loops of large bowel and blood results on admission showed an acute kidney injury (stage 3). A diagnosis of bowel obstruction was made initially but a CT scan of the abdomen showed bilateral obstructing calculi. After initial resuscitation, the patient had bilateral ultrasound-guided nephrostomies and haemofiltration. He later underwent bilateral antegrade ureteric stenting. A decision will later be made on whether or not he is fit enough to undergo ureteroscopy and laser stone fragmentation. 2016 BMJ Publishing Group Ltd.

  15. Ascites, a New Cause for Bilateral Hydronephrosis: Case Report

    PubMed Central

    Jain, Deepika; Dorairajan, Smrita; Misra, Madhukar

    2009-01-01

    Bilateral hydronephrosis secondary to urinary obstruction leads to a buildup of back pressure in the urinary tract and may lead to impairment of renal function. We present a case of a 57-year-old male with a history of alcoholic liver cirrhosis, who presented with tense ascites and acute renal failure. Bilateral hydronephrosis was seen on abdominal ultrasound. Multiple large-volume paracenteses resulted in resolution of hydronephrosis and prompt improvement in renal function. PMID:19802498

  16. Repeated and diverse losses of corolla bilateral symmetry in the Lamiaceae.

    PubMed

    Zhong, Jinshun; Preston, Jill C; Hileman, Lena C; Kellogg, Elizabeth A

    2017-05-01

    Independent evolution of derived complex characters provides a unique opportunity to assess whether and how similar genetic changes correlate with morphological convergence. Bilaterally symmetrical corollas have evolved multiple times independently from radially symmetrical ancestors and likely represent adaptations to attract specific pollinators. On the other hand, losses of bilateral corolla symmetry have occurred sporadically in various groups, due to either modification of bilaterally symmetrical corollas in late development or early establishment of radial symmetry. This study integrated phylogenetic, scanning electron microscopy (SEM)-based morphological, and gene expression approaches to assess the possible mechanisms underlying independent evolutionary losses of corolla bilateral symmetry. This work compared three species of Lamiaceae having radially symmetrical mature corollas with a representative sister taxon having bilaterally symmetrical corollas and found that each reaches radial symmetry in a different way. Higher core Lamiales share a common duplication in the CYCLOIDEA (CYC ) 2 gene lineage and show conserved and asymmetrical expression of CYC2 clade and RAD genes along the adaxial-abaxial floral axis in species having bilateral corolla symmetry. In Lycopus americanus , the development and expression pattern of La-CYC2A and La-CYC2B are similar to those of their bilaterally symmetrical relatives, whereas the loss of La-RAD expression correlates with a late switch to radial corolla symmetry. In Mentha longifolia , late radial symmetry may be explained by the loss of Ml-CYC2A , and by altered expression of two Ml-CYC2B and Ml-RAD genes . Finally, expanded expression of Cc-CYC2A and Cc-RAD strongly correlates with the early development of radially symmetrical corollas in Callicarpa cathayana . Repeated losses of mature corolla bilateral symmetry in Lamiaceae are not uncommon, and may be achieved by distinct mechanisms and various changes to symmetry

  17. Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids

    PubMed Central

    Rodriguez, Francisco A.; Portnuff, Cory D. F.; Goupell, Matthew J.; Tollin, Daniel J.

    2016-01-01

    In patients with bilateral hearing loss, the use of two hearing aids (HAs) offers the potential to restore the benefits of binaural hearing, including sound source localization and segregation. However, existing evidence suggests that bilateral HA users’ access to binaural information, namely interaural time and level differences (ITDs and ILDs), can be compromised by device processing. Our objective was to characterize the nature and magnitude of binaural distortions caused by modern digital behind-the-ear HAs using a variety of stimuli and HA program settings. Of particular interest was a common frequency-lowering algorithm known as nonlinear frequency compression, which has not previously been assessed for its effects on binaural information. A binaural beamforming algorithm was also assessed. Wide dynamic range compression was enabled in all programs. HAs were placed on a binaural manikin, and stimuli were presented from an arc of loudspeakers inside an anechoic chamber. Stimuli were broadband noise bursts, 10-Hz sinusoidally amplitude-modulated noise bursts, or consonant–vowel–consonant speech tokens. Binaural information was analyzed in terms of ITDs, ILDs, and interaural coherence, both for whole stimuli and in a time-varying sense (i.e., within a running temporal window) across four different frequency bands (1, 2, 4, and 6 kHz). Key findings were: (a) Nonlinear frequency compression caused distortions of high-frequency envelope ITDs and significantly reduced interaural coherence. (b) For modulated stimuli, all programs caused time-varying distortion of ILDs. (c) HAs altered the relationship between ITDs and ILDs, introducing large ITD–ILD conflicts in some cases. Potential perceptual consequences of measured distortions are discussed. PMID:27698258

  18. [Bilateral ovarian Burkitt's lymphoma. A case presentation].

    PubMed

    Briseño-Hernández, Andrés Alejandro; Quezada-López, Deissy Roxana; Castañeda-Chávez, Agar; Dassaejv Macías-Amezcua, Michel; Pintor-Belmontes, Julio Cesar

    2014-01-01

    Burkitt lymphoma, is described as an aggressive form of non-Hodgkin lymphoma of B cells which occurs most often in children and young adults, ovarian lymphoma can appear as a primary lesion or more commonly referred to as a metastasis. Primary ovarian lesions are rare manifestations corresponding to 0.5% of non-Hodgkin lymphoma and 1.5% of ovarian tumors. Clinic case: 31 years old female with general weakness, march incapacity, dyspnea, hyporexia, fever, diaphoresis, weight loss of 20 kg, flat abs with abdominal pain; Ca125 610 U/ml. Abdominal computed tomography shows a solid aspect tumor which affects the right pelvic cavity. Bilateral ovarian tumors were removed. Microscopically, both lesions show a "starry sky" pattern composed by a monotonous infiltration of lymphocytes mixed with large and clear macrophages, several atypical mitoses, and necrosis and hemorrhage areas. Immunohistochemistry was positive for CD10, CD20, and negative for CD3 and high Ki67 proliferation index. Bilateral ovarian Burkitt's lymphoma was diagnosed. Bilateral ovarian Burkitt's lymphoma is a rare entity, with a variability of presentations, the abdominal pain and abdominal tumors are the most frequent. The patient's prognosis at short term is poor, therefore it's necessary to know this entity and make an early diagnosis.

  19. Vestibular-Evoked Myogenic Potentials in Bilateral Vestibulopathy

    PubMed Central

    Rosengren, Sally M.; Welgampola, Miriam S.; Taylor, Rachael L.

    2018-01-01

    Bilateral vestibulopathy (BVP) is a chronic condition in which patients have a reduction or absence of vestibular function in both ears. BVP is characterized by bilateral reduction of horizontal canal responses; however, there is increasing evidence that otolith function can also be affected. Cervical and ocular vestibular-evoked myogenic potentials (cVEMPs/oVEMPs) are relatively new tests of otolith function that can be used to test the saccule and utricle of both ears independently. Studies to date show that cVEMPs and oVEMPs are often small or absent in BVP but are in the normal range in a significant proportion of patients. The variability in otolith function is partly due to the heterogeneous nature of BVP but is also due to false negative and positive responses that occur because of the large range of normal VEMP amplitudes. Due to their variability, VEMPs are not part of the diagnosis of BVP; however, they are helpful complementary tests that can provide information about the extent of disease within the labyrinth. This article is a review of the use of VEMPs in BVP, summarizing the available data on VEMP abnormalities in patients and discussing the limitations of VEMPs in diagnosing bilateral loss of otolith function. PMID:29719527

  20. A Powered Prosthetic Intervention for Bilateral Transfemoral Amputees

    PubMed Central

    Lawson, Brian E.; Ruhe, Brian; Shultz, Amanda; Goldfarb, Michael

    2014-01-01

    This paper presents the design and validation of a control system for a pair of powered knee and ankle prostheses to be used as a prosthetic intervention for bilateral transfemoral amputees. The control system leverages communication between the prostheses for enhanced awareness and stability, along with power generation at the knee and ankle joints to better restore biomechanical functionality in level ground walking. The control methodology employed is a combination of an impedance-based framework for weight-bearing portions of gait and a trajectory-based approach for the non-weight-bearing portions. The control system was implemented on a pair of self-contained powered knee and ankle prostheses, and the ability of the prostheses and control approach to provide walking functionality was assessed in a set of experimental trials with a bilateral transfemoral amputee subject. Specifically, experimental data from these trials indicate that the powered prostheses and bilateral control architecture provide gait kinematics that reproduce healthy gait kinematics to a greater extent than the subject’s daily-use passive prostheses. PMID:25014950

  1. Bilateral patching in retinal detachment: fluid mechanics and retinal "settling".

    PubMed

    Foster, William J

    2011-07-20

    When a patient suffers a retinal detachment and surgery is delayed, it is known clinically that bilaterally patching the patient may allow the retina to partially reattach or "settle." Although this procedure has been performed since the 1860s, there is still debate as to how such a maneuver facilitates the reattachment of the retina. Finite element calculations using commercially available analysis software are used to elucidate the influence of reduction in eye movement caused by bilateral patching on the flow of subretinal fluid in a physical model of retinal detachment. It was found that by coupling fluid mechanics with structural mechanics, a physically consistent explanation of increased retinal detachment with eye movements can be found in the case of traction on the retinal hole. Large eye movements increase vitreous traction and detachment forces on the edge of the retinal hole, creating a subretinal vacuum and facilitating increased subretinal fluid. Alternative models, in which intraocular fluid flow is redirected into the subretinal space, are not consistent with these simulations. The results of these simulations explain the physical principles behind bilateral patching and provide insight that can be used clinically. In particular, as is known clinically, bilateral patching may facilitate a decrease in the height of a retinal detachment. The results described here provide a description of a physical mechanism underlying this technique. The findings of this study may aid in deciding whether to bilaterally patch patients and in counseling patients on pre- and postoperative care.

  2. A patient with bilateral facial palsy associated with hypertension and chickenpox: learning points

    PubMed Central

    Al-Abadi, Eslam; Milford, David V; Smith, Martin

    2010-01-01

    Bilateral facial nerve paralysis is an uncommon presentation and even more so in children. There are reports of different causes of bilateral facial nerve palsy. It is well-established that hypertension and chickenpox causes unilateral facial paralysis and the importance of checking the blood pressure in children with facial nerve paralysis cannot be stressed enough. The authors report a boy with bilateral facial nerve paralysis in association with hypertension and having recently recovered from chickenpox. The authors review aspects of bilateral facial nerve paralysis as well as hypertension and chickenpox causing facial nerve paralysis. PMID:22797481

  3. CCM.FF-K3.2011: Final report for the CIPM key comparison of air speed, 0.5 m/s to 40 m/s

    NASA Astrophysics Data System (ADS)

    Müller, Harald; Caré, Isabelle; Lucas, Peter; Pachinger, Dietmar; Kurihara, Noboru; Lishui, Cui; Su, Chun-Min; Shinder, Iosif; Spazzini, Pier Giorgio

    2017-01-01

    The CCM.FF-K3.2011 comparison was organized for the purpose of determination of the degree of equivalence of the national standards for air speed over the range 0.5 m/s to 40 m/s. An ultrasonic anemometer and a Laser Doppler anemometer were used as transfer standards. Nine laboratories from three RMOs participated between July 2013 and July 2015—EURAMET: PTB, Germany; LNE-CETIAT, France; INRIM, Italy; VSL, The Netherlands; E+E, Austria; SIM: NIST, USA; APMP: NMIJ/AIST, Japan; NIM, China; CMS/ITRI, Chinese Taipei. The measurements were provided at ambient conditions. All results of independent participants were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each air speed separately following `procedure A' presented by M G Cox. The degree of equivalence with the KCRV was calculated for each air speed and laboratory. Almost all reported results were consistent with the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Fatal bilateral dioctophymatosis.

    PubMed

    Li, Gang; Liu, Caigang; Li, Fang; Zhou, Maoyi; Liu, Xiangyong; Niu, Yuanjie

    2010-12-01

    Dioctophyma renale is a parasite that frequently occurs in animals but rarely in humans. The present report describes the clinical observations of a D. renale infection in a 51-yr-old woman. Its clinical signs and diagnostic findings were unspecific until giant worms were observed in the urine and histological findings confirmed it was a D. renale infection. She refused treatment and died of bilateral renal function failure. This is the first confirmed report to follow the natural progression of D. renale infection in a human. Here, we discuss a conservative therapeutic approach and features associated with this parasitic infection.

  5. Poland syndrome with bilateral features: case description with review of the literature.

    PubMed

    Baban, Anwar; Torre, Michele; Bianca, Sebastiano; Buluggiu, Anna; Rossello, Mario Igor; Calevo, Maria Grazia; Valle, Maura; Ravazzolo, Roberto; Jasonni, Vincenzo; Lerone, Margherita

    2009-07-01

    Poland syndrome (PS) has been described as unilateral pectoral muscle deficiency variably associated with ipsilateral thoracic and upper limb anomalies. Bilateral hypoplasia/aplasia of the pectoralis muscle and upper limb defects in association with variable thoracic muscles, chest wall deformities and lower limb defects have been infrequently reported in the literature. We report on a 3(1/2)-year-old girl with clinical features consisting in bilateral asymmetric pectoral muscle defects (complete agenesis on the left side and agenesis of the sternocostal head on the right side), nipple hypoplasia, left rib defect, and right hand symbrachydactyly. In this study, we reviewed the bilateral features present in our patient and those described in the literature. Hypotheses explaining bilateral features in PS are reviewed.

  6. Bilateral custom-fit total knee arthroplasty in a patient with poliomyelitis.

    PubMed

    Tardy, Nicolas; Chambat, Pierre; Murphy, Colin G; Fayard, Jean-Marie

    2014-09-01

    In limbs affected by poliomyelitis, total knee arthroplasty results in satisfactory pain relief. However, the risk of failure is high, especially if the preoperative quadriceps power is low. Therefore, treating osteoarthritis in the current patient represented a challenging procedure. A 66-year-old man presented with tricompartmental osteoarthritis of both knees, with valgus deformity of 14° on the left knee and 11° on the right knee. He walked with a bilateral knee recurvatum of 30° and a grade 1 quadriceps power. The authors treated both knees with cemented custom-fit hinged total knee arthroplasty with 30° of recurvatum in the tibial keel. Clinical scores showed good results 1 year postoperatively, especially on the subjective data of quality of life and function. At follow-up, radiographs showed good total knee arthroplasty positioning on the right side and a small mechanical loosening at the end of the tibial keel on the left side. Only 5 studies (Patterson and Insall; Moran; Giori and Lewallen; Jordan et al; and Tigani et al) have reported total knee arthroplasty results in patients with poliomyelitis. This study reports an original case of bilateral custom-fit hinged total knee arthroplasty in a patient with poliomyelitis. To the authors' knowledge, this is the first report of this type of procedure in the literature. The key point is the degree of recurvatum that is needed to allow walking, avoiding excessive constraints on the implants that can lead to early mechanical failure. Copyright 2014, SLACK Incorporated.

  7. Are bilateral idiopathic clubfeet more severe than unilateral feet? A severity and treatment analysis.

    PubMed

    Agarwal, Anil; Agrawal, Nargesh; Barik, Sitanshu; Gupta, Neeraj

    2018-01-01

    Evidences suggest that different subgroups of idiopathic clubfoot exist with differences in severity and treatment outcomes. This study compares the severity and treatment outcomes of unilateral and bilateral clubfoot. We retrospectively studied 161 patients (bilateral 66, unilateral 95) with primary idiopathic clubfeet to evaluate the differences in severity and treatment. The parameters analyzed were precasting Pirani score, number of casts required, pretenotomy Pirani score, pretenotomy dorsiflexion, rate of tenotomy, and post-tenotomy dorsiflexion achieved. A Pirani score of at least 5 was classified as very severe and 4.5 or less was classified as less severe. There were 49=(74.24%) male and 17 (25.75%) female patients in the bilateral group and 76 (80%) male and 19 (20%) female patients in the unilateral group. Out of 95 unilateral patients, 34 were left sided (35.8%). Comparing severity, the mean precasting Pirani score in bilateral patients (5.4 ± 0.6) was statistically more than the unilateral patients (4.9 ± 0.7). The number of casts required was significantly more in bilateral feet compared to unilateral (bilateral 5.3 ± 1.7, unilateral 4.7 ± 1.7; p < 0.011). Achilles tenotomy was required in all feet. Post Ponseti treatment, the foot deformity correction achieved (pretenotomy Pirani score, pretenotomy, and post-tenotomy dorsiflexion) was statistically similar in both unilateral and bilateral feet. Idiopathic bilateral clubfoot was more severe than unilateral foot at initial presentation and required more number of corrective casts. Post Ponseti treatment, the deformity correction in bilateral foot was similar to unilateral foot.

  8. Variability of gait, bilateral coordination, and asymmetry in women with fibromyalgia.

    PubMed

    Heredia-Jimenez, J; Orantes-Gonzalez, E; Soto-Hermoso, V M

    2016-03-01

    To analyze how fibromyalgia affected the variability, asymmetry, and bilateral coordination of gait walking at comfortable and fast speeds. 65 fibromyalgia (FM) patients and 50 healthy women were analyzed. Gait analysis was performed using an instrumented walkway (GAITRite system). Average walking speed, coefficient of variation (CV) of stride length, swing time, and step width data were obtained and bilateral coordination and gait asymmetry were analyzed. FM patients presented significantly lower speeds than the healthy group. FM patients obtained significantly higher values of CV_StrideLength (p=0.04; p<0.001), CV_SwingTime (p<0.001; p<0.001), CV_StepWidth (p=0.004; p<0.001), phase coordination index (p=0.01; p=0.03), and p_CV (p<0.001; p=0.001) than the control group, walking at comfortable or fast speeds. Gait asymmetry only showed significant differences in the fast condition. FM patients walked more slowly and presented a greater variability of gait and worse bilateral coordination than healthy subjects. Gait asymmetry only showed differences in the fast condition. The variability and the bilateral coordination were particularly affected by FM in women. Therefore, variability and bilateral coordination of gait could be analyzed to complement the gait evaluation of FM patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Simultaneous vs sequential bilateral cataract surgery for infants with congenital cataracts: Visual outcomes, adverse events, and economic costs.

    PubMed

    Dave, Hreem; Phoenix, Vidya; Becker, Edmund R; Lambert, Scott R

    2010-08-01

    To compare the incidence of adverse events and visual outcomes and to compare the economic costs of sequential vs simultaneous bilateral cataract surgery for infants with congenital cataracts. Retrospective review of simultaneous vs sequential bilateral cataract surgery for infants with congenital cataracts who underwent cataract surgery when 6 months or younger at our institution. Records were available for 10 children who underwent sequential surgery at a mean age of 49 days for the first eye and 17 children who underwent simultaneous surgery at a mean age of 68 days (P = .25). We found a similar incidence of adverse events between the 2 treatment groups. Intraoperative or postoperative complications occurred in 14 eyes. The most common postoperative complication was glaucoma. No eyes developed endophthalmitis. The mean (SD) absolute interocular difference in logMAR visual acuities between the 2 treatment groups was 0.47 (0.76) for the sequential group and 0.44 (0.40) for the simultaneous group (P = .92). Payments for the hospital, drugs, supplies, and professional services were on average 21.9% lower per patient in the simultaneous group. Simultaneous bilateral cataract surgery for infants with congenital cataracts is associated with a 21.9% reduction in medical payments and no discernible difference in the incidence of adverse events or visual outcomes. However, our small sample size limits our ability to make meaningful comparisons of the relative risks and visual benefits of the 2 procedures.

  10. Bilateral anomalous origins of the posterior meningeal artery from the ascending pharyngeal arteries.

    PubMed

    Hsu, C Y; Sheu, J J; Huang, K M; Li, Y W

    2001-06-01

    We present a rare case of angiographically confirmed dural arteriovenous fistula supplied mainly by the posterior meningeal artery with bilateral anomalous origins from the bilateral ascending pharyngeal arteries. The bilaterality of the origins of the posterior meningeal artery is important in the angiographic diagnosis and management of a dural vascular malformation in the posterior fossa or the posterior part of the falx cerebri.

  11. Bilateral Superior Labial Mucosal Transposition Flaps to Correct Stenosis of the Nares Following Bilateral Rostral Maxillectomy Combined with Nasal Planum Resection in a Dog.

    PubMed

    Séguin, Bernard; Steinke, Julia R

    2016-04-01

    To describe a technique using labial mucosal flaps to correct stenosis of the nares subsequent to bilateral rostral maxillectomy and nasal planum resection. Case report Client-owned dog. A 10-year-old, neutered male Golden Retriever developed repeated stenosis of the nares, at first after bilateral rostral maxillectomy and nasal planum resection, and again after revision surgery. Bilateral, superior labial mucosal transposition flaps were created and interpolated between the nasal mucosa and skin after debridement of scar tissue. The stenosis did not recur after mucosal flap transposition and the dog returned to normal quality of life (last follow-up 25 months postoperative). Single-stage, superior labial mucosal transposition flaps can be used to correct nares stenosis subsequent to previous surgery. © Copyright 2016 by The American College of Veterinary Surgeons.

  12. Fulminant bilateral acute retinal necrosis after chickenpox - a case report.

    PubMed

    Dascalu, Ana Maria; Stana, Daniela; Popa-Cherecheanu, Alina; Popa-Cherecheanu, Matei; Serban, Dragos

    2016-01-01

    We present the case of a 34-year-old male, admitted for progressive bilateral loss of vision after a recent episode of chickenpox. Ophthalmological exam revealed bilateral acute retinal necrosis. As the patient was following a drug detoxification program, he was tested for HIV, HVB, HVC, and results highly positive. Immediate intravenous therapy with high doses of acyclovir and methylprednisolone was initiated, but the evolution was extremely severe resulting in necrotic retinal detachment. Surgery was performed in right eye, but no improvement of visual acuity was observed. The fulminant evolution of bilateral acute retinal necrosis and the lack of response to maximal intravenous therapy were clinical elements indicating coexistent immunosuppressive disease. Very severe acute retinal necrosis may occur in immunosuppressed patients, leading to blindness.

  13. Bilateral nevus comedonicus of the eyelids.

    PubMed

    Mendoza, Pia R; Jakobiec, Frederick A; Townsend, Daniel J

    2013-01-01

    Nevus comedonicus is a rare developmental abnormality of the infundibulum of the hair follicle. It is usually unilateral and commonly presents at birth or during childhood. A rare case of late-onset, bilateral nevus comedonicus of the eyelids is reported. A 79-year-old man presented with asymptomatic but disfiguring eyelid lesions noted several months earlier. On physical examination, multiple papules resembling comedones were present bilaterally in the eyelids, canthi, temple regions, and bridge of the nose. Microscopically, there were deep invaginations of the follicular canals forming focal tunnels or pseudosinus tracts with poral openings to the surface. These variably cystic structures were lined by keratinizing and nonkeratinizing squamous epithelium, contained concentric lamellae of keratin in their lumens, and some were acutely or chronically inflamed. The diagnosis of a nevus comedonicus was made. The clinical and histopathologic characteristics, pathogenesis, differential diagnosis, and management of nevus comedonicus are briefly discussed.

  14. Bilateral traumatic facial paralysis. Case report.

    PubMed

    Undabeitia, Jose; Liu, Brian; Pendleton, Courtney; Nogues, Pere; Noboa, Roberto; Undabeitia, Jose Ignacio

    2013-01-01

    Although traumatic injury of the facial nerve is a relatively common condition in neurosurgical practice, bilateral lesions related to fracture of temporal bones are seldom seen. We report the case of a 38-year-old patient admitted to Intensive Care Unit after severe head trauma requiring ventilatory support (Glasgow Coma Scale of 7 on admission). A computed tomography (CT) scan confirmed a longitudinal fracture of the right temporal bone and a transversal fracture of the left. After successful weaning from respirator, bilateral facial paralysis was observed. The possible aetiologies for facial diplegia differ from those of unilateral injury. Due to the lack of facial asymmetry, it can be easily missed in critically ill patients, and both the high resolution CT scan and electromyographic studies can be helpful for correct diagnosis. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  15. Final report on COOMET.QM-K76 (COOMET project no 484/RU/09): Key comparison of primary standard gas mixtures: SO2 in nitrogen (100 µmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Shor, N. B.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Kozia, V. G.; Shpilnyi, S. A.; Petryshyn, P. V.; Iakubov, S. E.; Kluchits, A. S.; Ananyin, V. N.; Mironchik, A. M.; Mokhnach, M. V.; Valkova, M.; Stovcik, V.

    2014-01-01

    Sulfur dioxide is one of the main contaminants present in the atmosphere due to burning of coal, oil and natural gas, smelting of base metals and production of sulfuric acid. Sulfur dioxide has been the subject of three previous CCQM key comparisons: CCQM-K1.d in 1997, CCQM-K26.b in 2005 and CCQM-K76 in 2010. VNIIM proposed a new COOMET project (No 484/RU/09) in this field, which was registered in the KCDB as key comparison COOMET.QM-K76. It was found that all results were consistent with the reference (gravimetric) values, with observed differences not exceeding ±0.60% and not exceeding either the appropriate assigned expanded uncertainties. VNIIM is the linking laboratory to CCQM-K76. SMU has improved the results obtained in CCQM-K76. The mixtures prepared for this exercise were found to be stable during about one year within the uncertainty of the measurements. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. KEY COMPARISON: Final report on CCQM-K62: Nutrients in infant/adult formula—Vitamins

    NASA Astrophysics Data System (ADS)

    Sharpless, Katherine E.; Rimmer, Catherine A.; Phinney, Karen W.; Nelson, Bryant C.; Duewer, David L.; Wise, Stephen A.; Kim, Byungjoo; Liu, Jun; Huang, Ting; Zhang, Wei

    2010-01-01

    Key comparison CCQM-K62 was designed to enable demonstration of the equivalence in capabilities for measurement of vitamins in a food matrix. A milk-based fortified human infant/adult formula was selected as the matrix based upon material availability and relevance. Because vitamins were added to the CCQM-K62 study material in a single form and at levels significantly higher than those that would be naturally occurring in the milk base, the ability of a laboratory to measure the study vitamins is only indicative of a laboratory's ability to measure vitamins in fortified foods. Target analytes were selected for study because of the ready availability of suitable standard materials and the range of their chemical properties: folic acid (vitamin B9) is a single water-soluble molecular entity that typically occurs at low levels and can be unstable, niacin (vitamin B3) is a single stable molecular entity and is typically present at higher concentrations than the other water-soluble vitamins, vitamin A has multiple molecular forms (including retinol and retinyl palmitate), is fat-soluble and typically occurs at relatively high levels. Results for participants measuring only folic acid or niacin are only indicative of their ability to make that measurement; results for participants measuring both folic acid and niacin are indicative of a laboratory's ability to measure folic acid, thiamine, niacin, and riboflavin in fortified foods but not vitamin C or other water-soluble vitamins. The ability to measure vitamin A (reported as retinol equivalents) in this material is also indicative of the participant's ability to measure vitamin E (as alpha-tocopherol and alpha-tocopheryl acetate) but is not indicative of the ability to measure vitamins D and K, which typically occur at much lower concentrations. The relative degrees of equivalence of the reported measurements for all three analytes in CCQM-K62 were within 10%; however, since only two results were submitted for niacin

  17. Laparoscopic bilateral transperitoneal adrenalectomy for Cushing syndrome: surgical challenges and lessons learnt.

    PubMed

    Aggarwal, Sandeep; Yadav, Kunal; Sharma, Aditya P; Sethi, Vrishketan

    2013-06-01

    Laparoscopic adrenalectomy is well established for treatment of adrenal lesions. However, bilateral adrenalectomy for Cushing syndrome is a challenging and time-consuming operation. We report our experience of laparoscopic bilateral adrenalectomy for this disease in 19 patients. From September 2009 to August 2012, we have operated 19 patients with Cushing syndrome and performed bilateral laparoscopic adrenalectomy using the transperitoneal approach; synchronous in 15 patients and staged in 4 patients. In 15 patients, the surgery was carried out sequentially on both the sides in lateral position with intraoperative change in position. Complete adrenalectomy including periadrenal fat was carried out on both the sides. Nineteen patients were referred from Department of Endocrinology for bilateral adrenalectomy for adrenocorticotropin hormone (ACTH)-dependent and ACTH-independent Cushing syndrome. The indications for surgery were Cushing disease in 15 patients, occult/ectopic source of ACTH in 2 patients, and primary adrenal hyperplasia in 2 patients. Fifteen patients underwent bilateral adrenalectomy during the same operation. Four patients underwent staged procedures. All procedures were completed laparoscopically with no conversions. The mean operating time for simultaneous bilateral adrenalectomy was 210 minutes (range, 150 to 240 min). This included the repositioning and reprepping time. There were no major intraoperative complications. The average blood loss was 100 mL (range, 50 to 200 mL). None of the patients required blood transfusions in the postoperative period. The postoperative complications included minor port-site infection in 2 patients. One severely debilitated patient died on the 14th postoperative day because of hospital-acquired pneumonia. The remaining 18 patients have done well in terms of impact on the disease. Laparoscopic bilateral adrenalectomy for Cushing syndrome is feasible and safe. It confers all the advantages of minimally invasive

  18. Bilateral methicillin-resistant staphylococcus aureus keratitis in a medical resident following an uneventful bilateral photorefractive keratectomy.

    PubMed

    Solomon, Renée; Donnenfeld, Eric D; Perry, Henry D; Biser, Seth

    2003-07-01

    To present a case of bilateral methicillin-resistant Staphylococcus aureus (MRSA) keratitis after photorefractive keratectomy (PRK). Retrospective chart review. RESULTS A 26-year-old female internal medicine resident underwent an uneventful bilateral PRK. After the procedure, the patient was fit with a bandage contact lens and was prescribed tobramycin 0.3%, fluorometholone 0.1%, and diclofenac sodium 0.1% four times per day. Postoperatively, corneal ulcers were noted in each eye, and the patient was referred for a consultation. Gram stain showed gram-positive cocci. The patient immediately started using vancomycin, 35 mg/mL every half hour, and ofloxacin 0.3% every hour around the clock. Forty-eight hours later, corneal and lid cultures were positive for MRSA. Three months after the infection, there was approximately 40% corneal thinning in the right eye and 10% thinning in the area of the corneal ulceration of the left eye. The patient is awaiting corneal transplantation of the right eye. To our knowledge, this represents the first reported case of bilateral MRSA keratitis after PRK. Methicillin-resistant S. aureus is a potentially serious infectious agent after PRK and may be associated with exposure to a hospital setting. For patients who have had extensive exposure to a hospital environment and are undergoing ocular surgery, we recommend prophylaxis against MRSA. To treat a possible MRSA keratitis, we suggest starting a fourth-generation topical fluoroquinolone every 30 minutes, alternating it with vancomycin 50 mg/mL every 30 minutes, and discontinuing steroid use. A high degree of suspicion coupled with rapid and appropriate treatment may result in improved visual recovery.

  19. Bilateral experimental neck pain reorganize axioscapular muscle coordination and pain sensitivity.

    PubMed

    Christensen, S W; Hirata, R P; Graven-Nielsen, T

    2017-04-01

    Neck pain is a large clinical problem where reorganized trunk and axioscapular muscle activities have been hypothesised contributing to pain persistence and pain hypersensitivity. This study investigated the effects of bilateral experimental neck pain on trunk and axioscapular muscle function and pain sensitivity. In 25 healthy volunteers, bilateral experimental neck pain was induced in the splenius capitis muscles by hypertonic saline injections. Isotonic saline was used as control. In sitting, subjects performed slow, fast and slow-resisted unilateral arm movements before, during and after injections. Electromyography (EMG) was recorded from eight shoulder and trunk muscles bilaterally. Pressure pain thresholds (PPTs) were assessed bilaterally at the neck, head and arm. Data were normalized to the before-measures. Compared with control and post measurements, experimental neck pain caused (1) decreased EMG activity of the ipsilateral upper trapezius muscles during all but slow-resisted down movements (p < 0.001), and (2) increased EMG activity in the ipsilateral erector spinae muscle during slow and fast movements (p < 0.02), and in the contralateral erector spinae muscle during all but fast up and slow-resisted down movements (p < 0.007). The PPTs in the painful condition increased at the head and arm compared with post measurements and the control condition (p < 0.001). In the post-pain condition, the neck PPT was decreased compared with the control condition (p < 0.001). Acute bilateral neck pain reorganized axioscapular and trunk muscle activity together with local hyperalgesia and widespread hypoalgesia indicating that acute neck pain immediately affects trunk and axioscapular function which may affect both assessment and treatment. Bilateral clinical neck pain alters axioscapular muscle coordination but only effects of unilateral experimental neck pain has been investigated. Bilateral experimental neck pain causes task-dependent reorganized

  20. [Simultaneous bilateral cataract surgery--advantages and disadvantages].

    PubMed

    Obuchowska, Iwona; Mariak, Zofia

    2006-01-01

    During the past decade, advances in techniques and technology led to major changes in cataract surgical practice patterns. In this progression towards ever faster eye rehabilitation after surgery, simultaneous bilateral cataract surgery (SBCS) may be the next and ultimate step. It is not routinely performed: however, there are certain situations in which SBCS might be beneficial to the patients. It has been considered a good option in patients who have significant cataract in both eyes and are not good candidates for having anesthesia and surgery twice. The question is, if the benefits by bilateral surgery justify the risk of simultaneous complications, in particular endophthalmitis. In this perspective we present the clinical, social and economic advantages and disadvantages of such surgical procedures.