Sample records for key comparison comparison

  1. Comparison is key.

    PubMed

    Stone, Mark H; Stenner, A Jackson

    2014-01-01

    Several concepts from Georg Rasch's last papers are discussed. The key one is comparison because Rasch considered the method of comparison fundamental to science. From the role of comparison stems scientific inference made operational by a properly developed frame of reference producing specific objectivity. The exact specifications Rasch outlined for making comparisons are explicated from quotes, and the role of causality derived from making comparisons is also examined. Understanding causality has implications for what can and cannot be produced via Rasch measurement. His simple examples were instructive, but the implications are far reaching upon first establishing the key role of comparison.

  2. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. KEY COMPARISON: Final report, on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII, 2007

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez Blaya, Carmen

    2009-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone mole fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. KEY COMPARISON: CCQM-K21 Key Comparison Determination of pp’-DDT in fish oil

    NASA Astrophysics Data System (ADS)

    Webb, K. S.; Carter, D.; Wolff Briche, C. S. J.

    2003-01-01

    A key comparison on the determination of (pp'-dichlorodiphenyl) trichloroethane (pp'-DDT) in a fish oil matrix has been successfully completed. Nine NMIs participated in this key comparison and used the technique of isotope dilution gas-chromatography mass spectrometry (ID/GC/MS) for the determinations. Two samples (A and B) of fish oil were distributed to participants, each gravimetrically spiked with pp'-DDT. The KCRV for Sample A is 0.0743 +/- 0.0020 µg g-1 and that of Sample B is 0.1655 +/- 0.0014 µg g-1 of pp'-DDT in fish oil. The results for Sample A showed a RSD of 3.5%, the RSD for Sample B was within 1%. These results were an improvement over those of the corresponding pilot study (CCQM-P21), where at a mass fraction of pp'-DDT in fish oil of 0.311 µg g-1 the RSD was 2.6%. The compound pp'-DDT is a typical organochlorine pesticide and this key comparison has shown that NMIs have the ability to measure such compounds at levels typically found in the environment. The compound (pp'-dichlorodiphenyl) dichloroethylene (pp'-DDE), a metabolite of pp'-DDT, was the subject of a previous key comparison (CCQM-K5). The compound pp'-DDT is technically more challenging than that of pp'-DDE since it can decompose during the measurement procedure. Consequently the success of this key comparison, combined with that of CCQM-K5 demonstrates a broad measurement capability by NMIs for organochlorine compounds in the environment. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  5. KEY COMPARISON: Final report of International Comparison EUROMET.QM-K1c: Comparison of measurements of nitrogen monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, A. M. H.; Nieuwenkamp, G.; Oudwater, R.; Wessel, R. M.; Novak, J.; Perrochet, J.-F.; Ackermann, A.; Rakowska, A.; Cortez, L.; Dias, F.; Konopelko, L.; Kustikov, Y.; Sutour, C.; Masé, T.; Milton, M. J. T.; Uprichard, I. J.; Woods, P. T.; Walden, J.; Lopez Esteban, M. T.

    2005-01-01

    Following-up the key comparison CCQM-K1c, EUROMET organized a regional key comparison involving ten laboratories. The objectives of this EUROMET key comparison were essentially the same as for the CCQM-K1c comparison: to compare the measurement capabilities of national metrological institutes (NMIs) in measuring amount of substance fractions of nitrogen monoxide in nitrogen. The nominal amount of substance fraction of the standards used for the comparison was 100 µmol/mol. The pilot laboratory in this key comparison also piloted the CCQM key comparison and has long-term experience in the behaviour of these mixtures and the technical challenges in preparing batches of very similar mixtures. Most participants used chemiluminescence as the measurement method; two participants used UV techniques and one ND-IR. The degrees of equivalence between this comparison and CCQM-K1c were calculated; four laboratories participated in both key comparisons, thus providing sufficient data for demonstrating the comparability. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  6. CCM key comparison CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.; Lenard, E.; Lee, Y. J.; Lee, W. G.; Madec, T.; Meury, P. A.; Caceres, J.; Santos, C.; Vamossy, C.; Man, J.; Fen, K.; Toda, K.; Wright, J.; Bettin, H.; Toth, H.

    2016-01-01

    This report presents the comparison philosophy, methodology, analysis and the results of the designed CCM.D-K4 key comparison that covered the calibration of high resolution hydrometers for liquid and alcoholometers in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20°C. The main purpose of this comparison was not only to evaluate the degree of equivalence in the calibration of high accuracy hydrometers between NMI participants, but also to link, were it is possible, the results of previous comparisons to Key Comparison Reference Values (KCRVs) of CCM.D-K4. Eleven NMI laboratories took part in the CCM.D-K4 divided in two groups (petals). With the CCM.D-K4 purpose, two similar sets consisting of three hydrometers for liquid density determinations and an alcoholometer were circulated to the NMI participants as a travelling standard in the time interval from January 2011 to April 2012. Twelve Key Comparison Reference Values (KCRVs) for each petal have been obtained at the density values related to the tested density marks of the transfer standards by the results of participants. The KCRVs and corresponding uncertainties were calculated by the weighted mean in the case of consistent results, otherwise the median was used. The degree of equivalence (DoE) with respect to the corresponding KCRV was determined for each participant and, in this particular comparison, the Weighted Least Squares (WLS) method was used to link the individual DoE of each participant by a continuous function. Significant drift of the transfer standards was not detected. This report also gives instructions on calculating pair-wise degrees of equivalence, with the addition of any information on correlations that may be necessary to estimate more accurately as well as the procedure for linking international comparisons to the CCM.D-K4. Finally an example of linkage to the CCM.D-K4 is given by dealing with the results of the bilateral comparison between INRiM and NMIA, which was

  7. Key comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Buchner, Christian; Zelenka, Zoltan; Kajastie, Heikki; Madec, Tanguy; Wolf, Henning; Vámossy, Csilla; Lorefice, Salvatore; Garberg, Torgunn; Lenard, Elżbieta; Spohr, Isabel; Mares, Gabriela; Spurný, Robert; Lumbreras, Angel; Medina, Nieves; Y Akçadağ, Ümit; Perkin, Michael

    2015-01-01

    Hydrostatic density determination for liquids is mainly performed by laboratories to provide means for calibrating liquid density measuring instruments such as oscillation-type density meters. From 2002 to 2005 the CIPM key comparison CCM.D-K2 'comparison of liquid density standards' was carried out piloted by the PTB. The aim was to compare the results of the density determination by the participating laboratories to support entries to the CMC tables in this sub-field. To provide further laboratories the possibility to support their entries to the CMC tables at the meeting of the EUROMET Working Group on Density in 2007 this comparison was agreed on. BEV (Austria) organized the comparison supported by the PTB (Germany). For the comparison samples of pentadecane, water, tetrachloroethylene and of an oil of high viscosity were measured in the temperature range from 5 °C to 60 °C at atmospheric pressure by hydrostatic weighing. The measurements were completed in 2008. The reference values of the first reports based on the draft of the CCM.D-K2. After the official publication of the CCM.D-K2 the reference values were recalculated and the report was finalised in 2015. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. KEY COMPARISON: Final report on international key comparison CCQM-K53: Oxygen in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Bok Lee, Jin; Moon, Dong Min; Seog Kim, Jin; van der Veen, Adriaan M. H.; Besley, Laurie; Heine, Hans-Joachim; Martin, Belén; Konopelko, L. A.; Kato, Kenji; Shimosaka, Takuya; Perez Castorena, Alejandro; Macé, Tatiana; Milton, Martin J. T.; Kelley, Mike; Guenther, Franklin; Botha, Angelique

    2010-01-01

    Gravimetry is used as the primary method for the preparation of primary standard gas mixtures in most national metrology institutes, and it requires the combined abilities of purity assessment, weighing technique and analytical skills. At the CCQM GAWG meeting in October 2005, it was agreed that KRISS should coordinate a key comparison, CCQM-K53, on the gravimetric preparation of gas, at a level of 100 µmol/mol of oxygen in nitrogen. KRISS compared the gravimetric value of each cylinder with an analytical instrument. A preparation for oxygen gas standard mixture requires particular care to be accurate, because oxygen is a major component of the atmosphere. Key issues for this comparison are related to (1) the gravimetric technique which needs at least two steps for dilution, (2) oxygen impurity in nitrogen, and (3) argon impurity in nitrogen. The key comparison reference value is obtained from the linear regression line (with origin) of a selected set of participants. The KCRV subset, except one, agree with each other. The standard deviation of the x-residuals of this group (which consists of NMIJ, VSL, NIST, NPL, BAM, KRISS and CENAM) is 0.056 µmol/mol and consistent with the uncertainties given to their standard mixtures. The standard deviation of the residuals of all participating laboratory is 0.182 µmol/mol. With respect to impurity analysis, overall argon amounts of the cylinders are in the region of about 3 µmol/mol however; four cylinders showed an argon amount fraction over 10 µmol/mol. Two of these are inconsistent with the KCRV subset. The explicit separation between two peaks of oxygen and argon in the GC chromatogram is essential to maintain analytical capability. Additionally oxygen impurity analysis in nitrogen is indispensable to ensure the preparative capability. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The

  9. KEY COMPARISON Final report on international comparison CCQM-K71: Measurement of stack gas

    NASA Astrophysics Data System (ADS)

    Nieuwenkamp, G.; van der Veen, A. M. H.; Wessel, R. M.; Qiao, Han; Oh, Sang-Hyub; Kim, Byung-Moon; Kim, Kwang-Sub; Pérez Castorena, Alejandro; Ramírez Nambo, Carlos; Koelliker Delgado, Jorge; Serrano Caballero, Victor M.; Rangel Murillo, Francisco; Avila Salas, Manuel de Jesus; Dias, Florbela; Baptista, Gonçalo; Konopelko, L. A.; Kustikov, Y. A.; Pankratov, V. V.; Selyukov, D. N.; Balandovich, V. S.; Vishnyakov, I. M.; Pavlov, M. V.; Maltsev, M. A.; Botha, Angelique; Valkova, Miroslava; Stovcik, Viliam; Musil, Stanislav; Milton, M. J. T.; Uprichard, I. J.; Vargha, G. M.; Guenther, F.; Gameson, L.; da Cunha, V.

    2010-01-01

    Industrial stack gas emission measurements are important for process control, control of air pollution, and for implementing legislation regarding carbon dioxide emission rights. Measurements are typically performed using a range of process analysers for carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOx), sulphur dioxide (SO2) and miscellaneous hydrocarbons. The calibration of these analysers is often performed using a series of binary mixtures of each component in nitrogen. For reasons of efficiency as well as a better match with true stack gas, the use of multi-component mixtures for this purpose would be preferred. The aim of this key comparison is to evaluate the measurement capabilities of national metrology institutes for carbon monoxide, carbon dioxide, nitrogen monoxide, sulphur dioxide and propane in nitrogen. Ten laboratories participated in the key comparison and one in the associated study. The key comparison reference value is based on the gravimetric preparation data. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison

    NASA Astrophysics Data System (ADS)

    Newell, D. B.; van Westrum, D.; Francis, O.; Kanney, J.; Liard, J.; Ramirez, A. E.; Lucero, B.; Ellis, B.; Greco, F.; Pistorio, A.; Reudink, R.; Iacovone, D.; Baccaro, F.; Silliker, J.; Wheeler, R. D.; Falk, R.; Ruelke, A.

    2017-01-01

    Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. KEY COMPARISON: Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

    NASA Astrophysics Data System (ADS)

    Hung, Chen-Chuan; Jian, Wu; Changpan, Tawat

    2009-01-01

    This report describes the key comparison APMP.M.P-K6.1 among the three national metrology institutes, Center for Measurement Standards-ITRI (CMS-ITRI, Taiwan), SPRING Singapore and National Institute of Metrology (NIMT), in the pressure range from 20 kPa to 105 kPa in gas media and gauge mode executed during the period April 2003 to April 2004. This comparison was conducted by CMS-ITRI and was based on the calibration procedure of APMP pneumatic pressure comparison APMP.M.P-K6. We intended to link to the CCM.P-K6 key comparison through the APMP.M.P-K6 key comparison by using the proposed linkage method in the APMP.M.P-K6 key comparison to determine a linking factor that can transform the quantities measured in the APMP.M.P-K6.1 key comparison. All three participating institutes used pneumatic piston gauges as their pressure standards. The Ruska 2465 gas-operated piston-cylinder assembly TL-1409 used as transfer standard offered by CMS-ITRI was calibrated three times by the pilot institute during the comparison period and showed that it was very stable after evaluation. The comparison was conducted on the basis of cross-float experiments to determine the effective area of transfer standards from the national standards of three institutes. The comparison results (as shown in Table 6) were equivalent to the CCM.P-K6 comparison and the relative bilateral degrees of equivalence between two laboratories were smaller than 39.7 × 10-6 from 20 kPa to 105 kPa. These results showed all participating institutes measuring the same quantity in the whole pressure range lay within their expanded uncertainty with confidence level 95%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. KEY COMPARISON: Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Kurupakorn, C.; Fletcher, N.; Stock, M.

    2010-01-01

    This report describes the results obtained from a NIMT (Thailand)-BIPM bilateral comparison of 10 kΩ resistance standards in 2009. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMIT and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was smaller than the uncertainty arising from the calibrations. The mean difference between the NIMT and the BIPM calibrations was found to be significantly larger than the expanded uncertainty (k = 2) of the comparison. However, this exercise allowed previously undetected sources of errors to be detected in the NIMT facility. A new bilateral comparison can be organized as soon as these problems are fixed. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. KEY COMPARISON: Key comparison CCQM-K60: Total selenium and selenomethionine in selenised wheat flour

    NASA Astrophysics Data System (ADS)

    Goenaga Infante, Heidi; Sargent, Mike

    2010-01-01

    Key comparison CCQM-K60 was performed to assess the analytical capabilities of national metrology institutes (NMIs) to accurately quantitate the mass fraction of selenomethionine (SeMet) and total selenium (at low mg kg-1 levels) in selenised wheat flour. It was organized by the Inorganic Analysis Working Group (IAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) as a follow-up key comparison to the previous pilot study CCQM-P86 on selenised yeast tablets. LGC Limited (Teddington, UK) and the Institute for National Measurement Standards, National Research Council Canada (NRCC, Ottawa, Canada) acted as the coordinating laboratories. CCQM-K60 was organized in parallel with a pilot study (CCQM-P86.1) involving not only NMIs but also expert laboratories worldwide, thus enabling them to assess their capabilities, discover problems and learn how to modify analytical procedures accordingly. Nine results for total Se and four results for SeMet were reported by the participant NMIs. Methods used for sample preparation were microwave assisted acid digestion for total Se and multiple-step enzymatic hydrolysis and hydrolysis with methanesulfonic acid for SeMet. For total Se, detection techniques included inductively coupled plasma mass spectrometry (ICP-MS) with external calibration, standard additions or isotope dilution analysis (IDMS); instrumental neutron activation analysis (INAA); and graphite furnace atomic absorption spectrometry (GFAAS) with external calibration. For determination of SeMet in the wheat flour sample, the four NMIs relied upon measurements using species-specific IDMS (using 76Se-enriched SeMet) with HPLC-ICP-MS. Eight of the nine participating NMIs reported results for total Se within 3.5% deviation from the key comparison reference value (KCRV). For SeMet, the four participating NMIs reported results within 3.2% deviation from the KCRV. This shows that the performance of the majority of the CCQM-K60 participants was very good

  14. Final report of the regional key comparison EURAMET.M.G-K1: European Comparison of Absolute Gravimeters ECAG-2011

    NASA Astrophysics Data System (ADS)

    Francis, Olivier; Klein, Gilbert; Baumann, Henri; Dando, Nicolas; Tracey, Ray; Ullrich, Christian; Castelein, Stefaan; Hua, Hu; Kang, Wu; Chongyang, Shen; Songbo, Xuan; Hongbo, Tan; Zhengyuan, Li; Pálinkás, Vojtech; Kostelecký, Jakub; Mäkinen, Jaakko; Näränen, Jyri; Merlet, Sébastien; Farah, Tristan; Guerlin, Christine; Pereira Dos Santos, Franck; Le Moigne, Nicolas; Champollion, Cédric; Deville, Sabrina; Timmen, Ludger; Falk, Reinhard; Wilmes, Herbert; Iacovone, Domenico; Baccaro, Francesco; Germak, Alessandro; Biolcati, Emanuele; Krynski, Jan; Sekowski, Marcin; Olszak, Tomasz; Pachuta, Andrzej; Agren, Jonas; Engfeldt, Andreas; Reudink, René; Inacio, Pedro; McLaughlin, Daniel; Shannon, Geoff; Eckl, Marc; Wilkins, Tim; van Westrum, Derek; Billson, Ryan

    2012-01-01

    During November 2011 a EURAMET key comparison of absolute gravimeters was organized in the Underground Laboratory for Geodynamics in Walferdange, Luxemburg. The comparison assembled 22 participants coming from 16 countries and four different continents. The comparison was divided into two parts: a key comparison that included six National Metrology Institutes or Designated Institutes, and a pilot study including all participants. The global result given by the pilot study confirms that all instruments are absolutely coherent with each other. The results obtained in the key comparison confirm a good agreement between the NMI instruments. Finally, a link to ICAG-2009 shows also that the NMI gravimeters are stable in time. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII (December 2014)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2015-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report on CCM key comparison CCM.D-K2: Comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Jacques, Claude; Zelenka, Zoltán; Fujii, Ken-ichi; Kuramoto, Naoki; Chang, Kyung-Ho; Lee, Yong Jae; Becerra, Luis Omar; Domostroeva, Natalia

    2013-01-01

    The results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10-5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database

  17. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII, March 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NPL, April 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Sweeney, Bryan; Quincey, Paul

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone standard of the United Kingdom maintained by the National Physical Laboratory (NPL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with VSL, September 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Heikens, Dita; van der Veen, Adrian

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Netherlands maintained by the Van Swinden (VSL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NIST, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Hodges, Joe; Norris, James E.

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the National Institute of Standards and Technology (NIST) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with INECC, September 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Fentanes, Oscar; Benítez, Ángeles; Ordoñez, Daniel

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of Mexico maintained by the National Institute of Ecology and Climate Change (INECC) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Final report on RMO Vickers key comparison COOMET M.H-K1

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Menelao, F.; Herrmann, K.; Aslanyan, A.; Pivovarov, V.; Galat, E.; Dovzhenko, Y.; Zhamanbalin, M.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales involving five National Metrology Institutes: PTB (Germany), BelGIM (Belarus), NSC IM (Ukraine), KazInMetr (Kazakhstan) and VNIIFTRI (Russia). The pilot laboratory was VNIIFTRI, and PTB acted as the linking institute to key comparisons CCM.H-K1.b and CCM.H-K1.c conducted for the Vickers hardness scales HV1 and HV30, respectively. The comparison was also conducted for the HV5 Vickers hardness scale, since this scale is most frequently used in practice in Russia and CIS countries that work according to GOST standards. In the key comparison, two sets of hardness reference blocks for the Vickers hardness scales HV1, HV5 and HV30 consisting each of three hardness reference blocks with hardness levels of 450 HV and 750 HV were used. The measurement results and uncertainty assessments for HV1 and HV30 hardness scales, as announced by BelGIM, NSC IM, KazInMetr and VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1.b and CCM.H-K1.c. The comparison results for the HV5 hardness scale are viewed as additional information, since up to today no CCM key comparisons on this scale have yet been carried out. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Report of the key comparison APMP.QM-K19. APMP comparison on pH measurement of borate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Obromsook, Krairerk; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Wong, Siu-Kay; Lam, Wai-Hing; Zakaria, Osman; Anuar Mohd. Amin, Khirul; Thanh, Ngo Huy; Máriássy, Michal; Vyskocil, Leos; Hankova, Zuzana; Fisicaro, Paola; Stoica, Daniela; Singh, Nahar; Soni, Daya; Ticona Canaza, Galia; Kutovoy, Viatcheslav; Barbieri Gonzaga, Fabiano; Dias, Júlio Cesar; Vospelova, Alena; Bakovets, Nickolay; Zhanasbayeva, Bibinur

    2015-01-01

    The APMP.QM-K19 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a borate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan (NMIJ) and the National Institute of Metrology (Thailand) (NIMT) at the APMP-TCQM meeting held 26-27 November 2012. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K19 and CCQM-K19.1. The comparison material was a borate buffer of pH around 9.2 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the second APMP key comparison on pH measurement and the fourth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006 and APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Regional comparison of absolute gravimeters, EURAMET.M.G-K2 key comparison

    NASA Astrophysics Data System (ADS)

    Pálinkáš, V.; Francis, O.; Val'ko, M.; Kostelecký, J.; Van Camp, M.; Castelein, S.; Bilker-Koivula, M.; Näränen, J.; Lothhammer, A.; Falk, R.; Schilling, M.; Timmen, L.; Iacovone, D.; Baccaro, F.; Germak, A.; Biolcati, E.; Origlia, C.; Greco, F.; Pistorio, A.; De Plaen, R.; Klein, G.; Seil, M.; Radinovic, R.; Reudink, R.; Dykowski, P.; Sȩkowski, M.; Próchniewicz, D.; Szpunar, R.; Mojzeš, M.; Jańk, J.; Papčo, J.; Engfeldt, A.; Olsson, P. A.; Smith, V.; van Westrum, D.; Ellis, B.; Lucero, B.

    2017-01-01

    In the framework of the regional EURAMET.M.G-K2 comparison of absolute gravimeters, 17 gravimeters were compared in November 2015. Four gravimeters were from different NMIs and DIs, they were used to link the regional comparison to the CCM.G.K2 by means of linking converter. Combined least-squares adjustments with weighted constraint was used to determine KCRV. Several pilot solutions are presented and compared with the official solution to demonstrate influences of different approaches (e.g. definition of weights and the constraint) on results of the adjustment. In case of the official solution, all the gravimeters are in equivalence with declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Final report, on-going key comparison BIPM.QM-K1: ozone at ambient level, comparison with DMDM, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, J.; Moussay, P.; Wielgosz, R.; Bebic, J.; Norris, J. E.; Guenther, F.

    2016-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Directorate of Measures and Precious Metals (DMDM) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NMISA, June 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Ntsasa, Napo G.; Tshilongo, James; Mphaphuli, Gumani E.; Norris, James E.; Hodges, Joseph T.

    2018-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of South Africa maintained by the National Metrology Institute of South Africa (NMISA) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2010)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2011-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2012)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2013-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Final report of the key comparison APMP.QM-K91: APMP comparison on pH measurement of phthalate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Ketrin, Rosi; Nuryatini; Thanh, Ngo Huy; Truong Chinh, Nguyen; Vospelova, Alena; Bastkowski, Frank; Sander, Beatrice; Matzke, Jessica; Prokunin, Sergey; Frolov, Dmitry; Aprelev, Alexey; Dobrovolskiy, Vladimir; Uysal, Emrah; Liv, Lokman; Velina Lara-Manzano, Judith; Montero-Ruiz, Jazmin; Ortiz-Aparicio, JosÉ Luis; Ticona Canaza, Galia; Anuar Mohd Amin, Khirul; Abd Kadir, Haslina; Bakovets, Nickolay; Wong, Siu-Kay; Lam, Wai-Hing

    2017-01-01

    The APMP.QM-K91 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phthalate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan at the APMP-TCQM meeting held September 22-23, 2014. After approval by TCQM, the comparison has been conducted by NMIJ. The comparison is a key comparison following CCQM-K91. The comparison material was a phthalate buffer of pH around 4.0 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the third APMP key comparison on pH measurement and the fifth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006, APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011 and APMP.QM-K19/APMP.QM-P25 (a borate buffer) in 2013-2014. The results can be used further by any participant to support its CMC claim at least for a phthalate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report of the key comparison APMP.QM-K9: APMP comparison on pH measurement of phosphate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Ohata, Masaki; Cherdchu, Chainarong; Tangpaisarnkul, Nongluck

    2011-01-01

    The APMP.QM-K9 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phosphate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan, NMIJ, and the National Institute of Metrology of Thailand, NIMT, in August 2009. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K9, CCQM-K9.1 and CCQM-K9.2. The comparison material was a phosphate buffer of pH around 6.86 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the first APMP key comparison on pH measurement and the third APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004 and APMP.QM-P09 (a phthalate buffer) in 2006. The results can be used further by any participant to support its CMC claim for a phosphate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the temperature(s) used or the full temperature range between 15 °C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with CMS-ITRI, June 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Lin, Tsai-Yin; Norris, James E.; Hodges, Joseph T.

    2017-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the ITRI Center for Measurement Standards (CMS-ITRI) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. KEY COMPARISON: Report of the spectral irradiance comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

    NASA Astrophysics Data System (ADS)

    Ojanen, M.; Shpak, M.; Kärhä, P.; Leecharoen, R.; Ikonen, E.

    2009-01-01

    A bilateral comparison of the spectral irradiance scales between MIKES (Finland) and NIMT (Thailand) was carried out at 22 wavelengths between 290 nm and 900 nm. MIKES acted as the pilot and link to the results of the key comparison CCPR-K1.a. The spectral irradiance values measured by NIMT generally agree with the key comparison reference value within the expanded uncertainty. The only exceptions are results at wavelengths 300 nm, 450 nm and 500 nm, where the ratios between the degree of equivalence (DoE) and the expanded uncertainty of DoE (k = 2) are 1.0, 1.4 and 1.2, respectively. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. SIM key comparison for luminous flux. SIM.PR-K4

    NASA Astrophysics Data System (ADS)

    Matamoros, Carlos H.; Ohno, Yoshi; Zwinkels, Joanne; Cogno, Jorge A.; Couceiro, Iakyra B.

    2016-01-01

    In compliance with the established BIPM and CCPR policies and guidelines on comparisons, the SIM Photometry and Radiometry Working Group decided to conduct a key comparison on total luminous flux in order to provide an opportunity for its member National Metrology Institutes (NMIs) that did not participate in the CCPR-K4 comparison, to get a link to the reference value obtained for this quantity (the lumen) and to derive the corresponding degrees of equivalence. This SIM.PR-K4 was piloted by Centro Nacional de Metrología (CENAM), the NMI of Mexico and included the participation of five laboratories: CENAM (Mexico), INTI (Argentina), INMETRO (Brazil), NIST (USA, linking lab), and NRC (Canada, linking lab). The comparison, conducted in star type scheme, was run using three to four lamps per participant, and results are given in this report, including the unilateral degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report of the APMP water flow key comparison: APMP.M.FF-K1

    NASA Astrophysics Data System (ADS)

    Lee, Kwang-Bock; Chun, Sejong; Terao, Yoshiya; Thai, Nguyen Hong; Tsair Yang, Cheng; Tao, Meng; Gutkin, Mikhail B.

    2011-01-01

    The key comparison, APMP.M.FF-K1, was undertaken by APMP/TCFF, the Technical Committee for Fluid Flow (TCFF) under the Asia Pacific Metrology Program (APMP). One objective of the key comparison was to demonstrate the degree of equivalence among six participating laboratories (KRISS, NMIJ, VMI, CMS, NIM and VNIIM) in water flow rate metrology by comparing the results with the key comparison reference value (KCRV) determined from the CCM.FF-K1 key comparison. The other objective of this key comparison was to provide supporting evidence for the calibration and measurement capabilities (CMCs), which had been declared by the participating laboratories during this key comparison. The Transfer Standard Package (TSP) was a Coriolis mass flowmeter, which had been used in the CCM.FF-K1 key comparison. Because the K-factors in the APMP.M.FF-K1 key comparison were slightly lower than the K-factors of the CCM.FF-K1 key comparison due to long-term drifts of the TSP, a correction value D was introduced. The value of D was given by a weighted sum between two link laboratories (NMIJ and KRISS), which participated in both the CCM.FF-K1 and the APMP.M.FF-K1 key comparisons. By this correction, the K-factors were laid between 12.004 and 12.017 at either low (Re = 254 000) or high (Re = 561 000) flow rates. Most of the calibration data were within expected uncertainty bounds. However, some data showed undulations, which gave large fluctuations of the metering factor at Re = 561 000. Calculation of degrees of equivalence showed that all the participating laboratories had deviations between -0.009 and 0.007 pulses/kg from the CCM.FF-K1 KCRV at either the low or the high flow rates. In case of En calculation, all the participating laboratories showed values less than 1, indicating that the corrected K-factors of all the laboratories were equivalent with the KCRV at both Re = 254 000 and 561 000. When the corrected K-factors from two participating laboratories were compared, all the

  17. KEY COMPARISON: Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Giera, Janine; Fraga, Isabel C.; Tønnes Jakobsen, Pia; Jensen, Hans D.; Hyllested, Peter; Karpov, Oleg; Kutovoy, Viatcheslav; Nakamura, Susumu; Vospelova, Alena; Zvezdina, Valentina

    2008-01-01

    CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were 15 °C, 25 °C, 37 °C. CCQM-K9.2, CCQM-K.9 and the first supplementary comparison CCQM-K9.1 [5] are activities of the Electrochemical Working Group (EAWG) of the CCQM. All three comparisons were coordinated by the PTB, Germany. The Danish Primary Laboratory (DPL) successfully took part in the CCQM-K9. Meanwhile the primary set-up for pH in Denmark moved from DPL affiliated to Radiometer Medical to DFM, Denmark. The subsequent comparison allows assessing the degree of equivalence for the measurement of pH at DFM after the move. Due to the interest of other laboratories in demonstrating their progress in pH measurements on the primary level the CCQM-K9.2 supplementary comparison was extended to other participants than DFM, namely NMIJ, VNIIFTRI, INMETRO and CMI. The reported quantity for CCQM-K9.2 was not the pH of the sample but the acidity function at zero chloride molality (see chapter 12). To calculate the pH value from the acidity function it is necessary to know the ionic strength of the sample buffer solution, which was undisclosed by the coordinator. With the exception of the Czech Metrology Institute, CMI, good agreement in the determined acidity function is found between the participants. The results reported by DFM and by PTB agree within their measurement uncertainty at all measurement temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report

  18. KEY COMPARISON: Final report of comparison of the calibrations of hydrometers for liquid density determination between SIM laboratories: SIM.M.D-K4

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar

    2009-01-01

    This SIM comparison on the calibration of high accuracy hydrometers was carried out within fourteen laboratories in the density range from 600 kg/m3 to 1300 kg/m3 in order to evaluate the degree of equivalence among participant laboratories. This key comparison anticipates the planned key comparison CCM.D-K4, and is intended to be linked with CCM.D-K4 when results are available. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Final report on the key comparison CCPR-K5: Spectral diffuse reflectance

    NASA Astrophysics Data System (ADS)

    Nadal, Maria; Eckerle, Kenneth L.; Early, Edward A.; Ohno, Yoshi

    2013-01-01

    The CCPR K5 key comparison on spectral diffuse reflectance was carried out in the framework of the CIPM Mutual Recognition Arrangement, by 13 national metrology institutes (MMIs) as participants. The participants were CSIR-NML (South Africa), HUT (Finland), IFA-CSIC (Spain), KRISS (Republic of Korea), MSL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NPL (United Kingdom), NRC (Canada), OMH (Hungary), PTB (Germany) and VNIIOFI (Russia Federation). NIST (USA) piloted the comparison. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 820 nm at 20 nm increment. The comparison was a star type comparison with the samples provided by the pilot laboratory and with the measurement sequence: Pilot-Participant-Pilot. Spectralon and matte white ceramic tiles were used as the transfer standards. Each participant received three of each type of sample and at least one sample of each type was measured three times on three separate days, and the other two samples were measured once. The report presents the description of the measurement facilities, procedures and uncertainties of all the participants as well as the results of the comparison. Measurement results from the participants and their associated uncertainties were analyzed in accordance with the Guidelines for CCPR Key Comparison Report Preparation, using weighted mean with cut-off. For the calculation of the Key Comparison Reference Value (KCRV), as agreed by the participants, the data of both samples were used for the 460 nm to 820 nm region and only the data of the Spectralon samples were used in the spectral region of 360 nm to 440 nm. The unilateral degrees of equivalence (DoE) calculated for each participant are mostly consistent within the uncertainty (k = 2) of the DoE. This international comparison of spectral diffuse reflectance

  20. KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. Final report of the key comparison of APMP.AUV.V-K2

    NASA Astrophysics Data System (ADS)

    Usuda, Takashi; Ota, Akihiro; Nozato, Hideaki; Ishigami, Tamio; Kokuyama, Wataru; Plangsangmas, Virat; Rattanangkul, Pairoj; Yih Tsuei, Kuang; Huang, Yu-Chung; Chee Keong, Chan; Shan, Cui

    2017-01-01

    A key comparison of vibration acceleration APMP.AUV.V-K2, which is an upgrade from APMP.AUV.V-K1.1, has been made within the Asia Pacific Metrology Programme (APMP) to include three national laboratories; the CMS-ITRI (Chinese Taipei), the NIMT (Thailand) and the A*Star (Singapore). One pilot laboratory, the NMIJ (Japan), participated to link the RMO APMP results to the CIPM CC key comparison (CCAUV.V-K2), according to the decision of the CCAUV10/D7 during the 10th CCAUV meeting. The admissible acceleration amplitude ranges from 10 m/s2 to 200 m/s2 over the frequency range from 40 Hz to 5 kHz. The RMO APMP results demonstrate the agreement with the key comparison reference value of CCAUV.V-K2 within the expanded uncertainties considering the armature effect of vibration exciter in a high-frequency range. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. KEY COMPARISON: Final Report on CCT-K7: Key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Stock, M.; Solve, S.; del Campo, D.; Chimenti, V.; Méndez-Lango, E.; Liedberg, H.; Steur, P. P. M.; Marcarino, P.; Dematteis, R.; Filipe, E.; Lobo, I.; Kang, K. H.; Gam, K. S.; Kim, Y.-G.; Renaot, E.; Bonnier, G.; Valin, M.; White, R.; Dransfield, T. D.; Duan, Y.; Xiaoke, Y.; Strouse, G.; Ballico, M.; Sukkar, D.; Arai, M.; Mans, A.; de Groot, M.; Kerkhof, O.; Rusby, R.; Gray, J.; Head, D.; Hill, K.; Tegeler, E.; Noatsch, U.; Duris, S.; Kho, H. Y.; Ugur, S.; Pokhodun, A.; Gerasimov, S. F.

    2006-01-01

    accepted this recommendation and the next edition of the SI brochure will include this specification. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Allisy-Roberts, P. J.; Burns, D. T.; Guerra, A. S.; Laitano, R. F.; Pimpinella, M.

    2010-01-01

    A comparison of the standards for absorbed dose to water of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI), and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation under the auspices of the key comparison BIPM.RI(I)-K4. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the ENEA and the BIPM standards for absorbed dose to water, is 0.9999 (0.0044). The present 2007 result replaces the earlier ENEA value in this key comparison. The degrees of equivalence between the ENEA and the other participants in this comparison have been calculated and the results are given in the form of a matrix for the ten national metrology institutes (NMIs) that have published results in this ongoing comparison for absorbed dose to water. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. KEY COMPARISON: Report on the Regional Comparison COOMET.AUV.A-K3

    NASA Astrophysics Data System (ADS)

    Barrera-Figueroa, Salvador; Nielsen, Lars; Rasmussen, Knud

    2007-01-01

    COOMET.AUV.A-K3 is a Regional Comparison that supplements the Key Comparison CCAUV.A-K3 organized by the CCAUV. The participating NMIs are GUM (Poland), INM (Romania), VNIIFTRI (Russia) and DP-NDI 'Systema' (Ukraine). The role of Pilot laboratory was undertaken by DPLADFM (Denmark). The measurements took place between May 2005 and February 2006. The time schedule was organized in a single star configuration. Initially, two LS2aP microphones were circulated. However, a sudden change of sensitivity of one of them forced the inclusion of an additional microphone. Nevertheless, the analysis was performed on all microphones involved. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignation of degrees of equivalence and the link to the CCAUV.A-K3. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Bilateral key comparison on luminous flux COOMET.PR-K4.1. final report

    NASA Astrophysics Data System (ADS)

    Huriev, M.; Khlevnoy, B.; Tolstykh, G.; Ivashin, E.; Gorchkova, T.

    2017-01-01

    This report describes an international bilateral key comparison on luminous flux of tungsten lamps between the National Scientific Centre 'Institute of Metrology' (NSC 'IM', Ukraine) and All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI, Russia). The comparison is intended to determine the Degrees of Equivalence (DoE) for NSC 'IM' and the associated expanded uncertainty. VNIIOFI acts as a laboratory, providing the link to the comparison CCPR-K4. The comparison used a set of tungsten incandescent lamps as a transfer standard with a luminous flux of approximately 3800 lm. The determined DoE of NSC 'IM' is -0.94% with an expanded uncertainty (k = 2) of 1.05%. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. KEY COMPARISON: CCQM-K27-Subsequent: Key Comparison (subsequent) for the determination of ethanol in aqueous matrix

    NASA Astrophysics Data System (ADS)

    Schantz, Michele M.; Duewer, David L.; Parris, Reenie M.; May, Willie E.; Archer, Marcellé; Mussell, Chris; Carter, David; Konopelko, Leonid A.; Kustikov, Yury A.; Krylov, Anatoli I.; Fatina, Olga V.

    2005-01-01

    Ethanol is important both forensically ('drunk driving' or driving while under the influence, 'DWI', regulations) and commercially (alcoholic beverages). Blood- and breath-alcohol testing can be imposed on individuals operating private vehicles such as cars, boats, or snowmobiles, or operators of commercial vehicles like trucks, planes, and ships. The various levels of blood alcohol that determine whether these operators are considered legally impaired vary depending on the circumstances and locality. Accurate calibration and validation of instrumentation is critical in areas of forensic testing where quantitative analysis directly affects the outcome of criminal prosecutions, as is the case with the determination of ethanol in blood and breath. Additionally, the accurate assessment of the alcoholic content of beverages is a commercially important commodity. In 2002, the CCQM conducted a Key Comparison (CCQM-K27) for the determination of ethanol in aqueous matrix with nine participants. A report on this project has been approved by the CCQM and can be found at the BIPM website and in this Technical Supplement. CCQM-K27 comprised three samples, one at low mass fraction of ethanol in water (nominal concentration of 0.8 mg/g), one at high level (nominal concentration of 120 mg/g), and one wine matrix (nominal concentration of 81 mg/g). Overall agreement among eight participants using gas chromatography with flame ionization detection (GC-FID), titrimetry, isotope dilution gas chromatography/mass spectrometry (GC-IDMS), and gas chromatography-combustion-isotope ratio mass spectrometry (ID-GC-C-IRMS) was good. The ninth participant used a headspace GC-FID method that had not been validated in an earlier pilot study (CCQM-P35). A follow-on Key Comparison, CCQM-K27-Subsequent, was initiated in 2003 to accommodate laboratories that had not been ready to benchmark their methods in the original CCQM-K27 study or that wished to benchmark a different method. Four levels of

  7. CCQM-K103 key comparison melanine in milk powder

    NASA Astrophysics Data System (ADS)

    Li, Xiuqin; Zhang, Qinghe; Li, Hongmei; Li, Mengwan; Wong, Siu-kay; Lee, Foo-Wing; Kakoulides, Elias; Naujaus, Evaldas; Fernandes-Whaley, Maria; Prevoo-Franzsen, Des; Quinn, Laura; Pookrod, Preeyaporn; Konopelko, Leonid

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K103, was coordinated by the National Institute of Metrology (NIM) and Government Laboratory, Hong Kong, China (GLHK). The comparison was designed to demonstrate NMIs/DIs ability to analyze traces of melamine in milk and milk powder at concentration levels resulting from requirements for food safety. Seven NMIs or DIs participated in the comparison. Final reference value (KCRV) is 0.286 mg/kg, with standard uncertainty of the median as 0.011 mg/kg (3.8 %). The k-factor for the estimation of the expanded uncertainty was chosen as k = 2.57 ( t (0.05;5) ), thus the expanded uncertainty is 0.028 mg/kg (9.8%). The degrees of equivalence with melamine in milk powder KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for IDMS in determining mass fractions in the range from 0.1 to 5.0 mg/kg of analytes with low molar mass (range 50-300 Da) with high polarity (pKow > -2.0) in milk and milk products. Extension to other analytes and matrices should be applied with care since there is a close linkage to other relevant parameters as e.g. sample preparation procedures (liquid/liquid extraction, SPE clean-up) and analytical separation techniques (e.g., GC-MS, LC-MS/MS etc). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 1 Ω resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Two BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The mean difference between the NMLI and the BIPM calibrations was found to be just within the expanded uncertainty (k = 2) of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Final report on EUROMET key comparison EUROMET.M.D-K2 (EUROMET 627) "Comparison of density determinations of liquid samples"

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Heinonen, Martti; Gosset, André; Zelenka, Zoltán; Lorefice, Salvatore; Hellerud, Kristen; Durlik, Hanna; Jordaan, Werner; Field, Ireen

    2016-01-01

    The results of the key comparison EUROMET 627 (EUROMET.M.D-K2) are presented. This project covered the density measurements of three liquids: dodecane, water and an oil of high viscosity measured at 15 °C, 20 °C and 40 °C. Seven European metrology laboratories and the South African laboratory CSIR-NML (now: NMISA) measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards between 04 October 2001 and 18 December 2001. The stability and homogeneity of the liquids were investigated by the pilot laboratory PTB. The results generally show good agreement among the participants. Only for the simple Mohr-Westphal balances do the uncertainties seem to be underestimated by the laboratories. Furthermore, the measurement of high-viscosity oil was difficult for some laboratories. Nevertheless, the five laboratories PTB/DE, BNM/FR (now: LNE/FR), OMH/HU (now: MKEH/HU), IMGC/IT (now: INRIM/IT) and GUM/PL agree with each other for stated uncertainties of 0.05 kg/m3 or less. This satisfies the current needs of customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. No reference values were calculated since the subsequent CCM key comparison CCM.D-K2 had a different scope and the EUROMET 627 comparison was soon superseded by the EURAMET 1019 (EURAMET.M.D-K2) comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. KEY COMPARISON: BIPM comparison BIPM.RI(II)-K1.Cu-64 of the activity measurements of the radionuclide 64Cu

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Kossert, K.; Nähle, O. J.

    2009-01-01

    In 2009, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted a sample of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The value of the activity submitted was about 9.3 MBq. The result of this new comparison has been approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), comparison identifier BIPM.RI(II)-K1.Cu-64. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 10 kΩ resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NMLI and the BIPM calibrations were found to be in agreement, with a mean difference smaller than the standard uncertainty of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. EURAMET.T-K7 Key Comparison of Water Triple-Point Cells

    NASA Astrophysics Data System (ADS)

    Peruzzi, A.; Bosma, R.; Kerkhof, O.; Rosenkranz, P.; Del Campo Maldonado, M. D.; Strnad, R.; Nielsen, J.; Anagnostou, M.; Veliki, T.; Zvizdic, D.; Grudnewicz, E.; Nedea, M.; Neagu, D. M.; Steur, P.; Filipe, E.; Lobo, I.; Antonsen, I.; Renaot, E.; Heinonen, M.; Weckstrom, T.; Bojkovski, J.; Turzo-Andras, E.; Nemeth, S.; White, M.; Tegeler, E.; Dobre, M.; Duris, S.; Kartal Dogan, A.; Uytun, A.; Augevicius, V.; Pauzha, A.; Pokhodun, A.; Simic, S.

    2011-12-01

    The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the "mother" comparison CCT-K7 is discussed in detail.

  13. Key comparison CCPR-K1.a as an interlaboratory comparison of correlated color temperature

    NASA Astrophysics Data System (ADS)

    Kärhä, P.; Vaskuri, A.; Pulli, T.; Ikonen, E.

    2018-02-01

    We analyze the results of spectral irradiance key comparison CCPR-K1.a for correlated color temperature (CCT). For four participants out of 13, the uncertainties of CCT, calculated using traditional methods, not accounting for correlations, would be too small. The reason for the failure of traditional uncertainty calculation is spectral correlations, producing systematic deviations of the same sign over certain wavelength regions. The results highlight the importance of accounting for such correlations when calculating uncertainties of spectrally integrated quantities.

  14. KEY COMPARISON: Final report on bilateral comparison CCEM.RF-K9.1: Thermal noise standards at 12.4 GHz, 13.5 GHz, 15 GHz and 17.5 GHz

    NASA Astrophysics Data System (ADS)

    Allal, Djamel

    2009-01-01

    A bilateral comparison subsequent to key comparison CCEM.RF-K9 was decided between VNIIFTRI and PTB. It was registered into the BIPM KCDB under the identifier CCEM.RF-K9.1. The results of this comparison were gathered by the pilot laboratory of comparison CCEM.RF-K9, the LNE, and a very good agreement was found between the two participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. KEY COMPARISON Bilateral comparison of 1.018 V and 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2010 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2010-01-01

    As a part of the ongoing BIPM key comparisons BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and of the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2010. Two BIPM Zener diode-based travelling standards were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage is maintained at the 10 V level by means of a group of characterized Zener diode-based electronic voltage standards. The output EMF of each travelling standard, at the 10 V output terminals, was measured by direct comparison with the group standard. Measurements of the output EMF of the travelling standards at the 1.018 V output terminals were made using a potentiometer, standardized against the local 10 V reference standard. At the BIPM, the travelling standards were calibrated at both voltages before and after the measurements at NSAI-NML, using the BIPM Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Final report on CIPM key comparison CCM.FF-K6.2011: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John

    2014-01-01

    The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. KEY COMPARISON Final report on APMP.EM-K6.a: APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty

    NASA Astrophysics Data System (ADS)

    Budovsky, Ilya

    2010-01-01

    The APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty, APMP.EM-K6a, started in 2000 and concluded in 2003. This comparison has offered the same range and frequencies as the key comparison CCEM-K6a with the view of providing the National Metrology Institutes (NMIs) of the APMP member economies with an opportunity to link the values of their standards for ac-dc transfer difference to the international reference values. The ac-dc difference of the travelling standard was measured with 3 V applied at standard frequencies of 1 kHz, 20 kHz, 100 kHz and 1 MHz, and optional frequencies of 50 kHz and 500 kHz. The travelling standard has not been damaged and has shown excellent stability. The results submitted by the overwhelming majority of the participants lie well within the reported uncertainty. At the standard frequencies the results have been linked to those of the CCEM-K6a key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  18. The comparison and analysis of extracting video key frame

    NASA Astrophysics Data System (ADS)

    Ouyang, S. Z.; Zhong, L.; Luo, R. Q.

    2018-05-01

    Video key frame extraction is an important part of the large data processing. Based on the previous work in key frame extraction, we summarized four important key frame extraction algorithms, and these methods are largely developed by comparing the differences between each of two frames. If the difference exceeds a threshold value, take the corresponding frame as two different keyframes. After the research, the key frame extraction based on the amount of mutual trust is proposed, the introduction of information entropy, by selecting the appropriate threshold values into the initial class, and finally take a similar mean mutual information as a candidate key frame. On this paper, several algorithms is used to extract the key frame of tunnel traffic videos. Then, with the analysis to the experimental results and comparisons between the pros and cons of these algorithms, the basis of practical applications is well provided.

  19. Final report on key comparison CCQM-K81: Chloramphenicol in pig muscle

    NASA Astrophysics Data System (ADS)

    Polzer, Joachim; Henrion, Andre; Gowik, Petra

    2013-01-01

    Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K81 'Chloramphenicol in pig muscle', was coordinated by BVL and PTB in 2009/2010. Six NMIs/DIs participated in this comparison. Chloramphenicol (CAP) is an effective broad-spectrum antibiotic which can in principle be used for the treatment of humans and animals. Its use for the treatment of food-producing animals is, however, forbidden worldwide in many countries due to potential severe side effects. The key comparison was the follow-up to the successful pilot study 'CCQM-P90: chloramphenicol in milk'. With this key comparison it was intended to demonstrate the capability of NMIs/DIs to analyse traces of CAP in food at concentration levels resulting from legal requirements for food control. Additionally, the quality of this kind of analysis with respect to compliance with legal requirements for food control methods and the international comparability of measurements should be evaluated in general. The study was classified as a 'track C' study (studies in emerging areas of global interest). For the study incurred lyophilised pig muscle material containing CAP (at a mass-fraction level around the maximum allowable level for import for a number of countries) has been produced as a candidate reference material by BVL and IRMM (Institute for Reference Materials and Measurements, JRC of the European Commission). Animal treatment and slaughtering of the animal to gain incurred muscle material as well as pre-testing of the CAP content was done at the BVL. The IRMM did further processing of the material and testing of homogeneity and stability. Participants were invited to assign the mass fraction of free CAP in the comparison sample. CCQM-K81 demonstrated successfully the capability of the participating laboratories to assign chloramphenicol values in tissue down to residue levels of around 0.3 ng/g (referring to the

  20. Linking results of key and supplementary comparisons of AC/DC voltage transfer references

    NASA Astrophysics Data System (ADS)

    Velychko, Oleh

    2018-04-01

    A regional key comparison (KC) COOMET.EM-K6.a and a supplementary comparison (SC) COOMET.EM-S1 of AC/DC voltage transfer references were conducted between participating laboratories from the Eurasian region. Measurements were made over the period 2004-2014. The results showed good agreement between all but one of the participating laboratories. The proposed procedure of linking results of key and SCs of regional metrology organization of AC/DC voltage transfer references is presented. Linking results is realized for COOMET.EM-K6.a and CCEM-K6.a KCs, and for COOMET.EM-K6.a KC and COOMET.EM-S1 SC.

  1. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Burns, D. T.; Berlyand, V.; Berlyand, A.

    2010-01-01

    A new comparison of the standards for absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation in 2009. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9976 for the calibration coefficients of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. This result is consistent with the earlier 2001 comparison result of 0.9967 (43). The updated degrees of equivalence for the VNIIFTRI are compared with those of the other national metrology institutes as presented in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. KEY COMPARISON: Final report on Key Comparison APMP.SIM.M.P-K1c: Bilateral comparison between NIST (USA) and NPLI (India) in the pneumatic pressure region 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Driver, R. Gregory; Olson, Douglas A.; Dilawar, Nita; Bandyopadhyay, A. K.

    2007-01-01

    We report the results of a bilateral comparison of pressure measurement between NIST and NPLI using a piston gauge transfer standard (TS), designated as NPLI-4, over the range of nominal applied pressure 0.4 MPa to 4.0 MPa. This TS was cross-floated against the laboratory secondary standard designated as PG13 at NIST, USA and against NPLI-8 at NPLI, India. The nominal pressure points of the bilateral comparison were (0.4, 0.8, 1.2, 1.6, 2.0, 2.4, 2.8, 3.2, 3.6 and 4.0) MPa, respectively. The comparison was performed in both the institutes in identical pressure cycles in increasing pressures. The comparison data were analysed in terms of the effective area [Ap (mm2)] as a function pressure [p (MPa)] of the TS at the above-mentioned pressures. We have also estimated the zero-pressure effective area [A0 (mm2)] and the pressure distortion coefficient [λ (MPa-1)] of the transfer standard. The consistency of the results at every pressure in the range indicates that the laboratory standards used in this comparison are compatible, uniform and can be considered traceable to each other. Finally, the degree of equivalence between NPLI and NIST is 11.4 × 10-6 or better, which is always less than the relative standard uncertainty of the difference (33.6 × 10-6). Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. CCQM key comparison CCQM-K75: Determination of toxic metals in algae

    NASA Astrophysics Data System (ADS)

    Shakhashiro, A.; Toervenyi, A.; Gaudino, S.; Rosamilia, S.; Belli, M.; Turk, G. C.

    2011-01-01

    The determination of mass fraction of toxic elements and especially platinum emitted from automobile catalytic converters in the air is a critical factor in assessing air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to toxic elements. Biomonitors, such as lichen and algae, are examples of environmental samples that have been widely used by the scientific community to assess and monitor the level of environmental pollution. For this purpose, the IAEA-450 algae material containing heavy metals and platinum at low level was prepared by IAEA Seibersdorf Laboratories in collaboration with the Italian National Institute for Environmental Protection—ISPRA (former APAT). During the April meeting in 2009 of the Inorganic Analysis Working Group (IAWG) of the CCQM it was agreed to organize a key comparison K75 for Pt and Ni and a parallel pilot study P118 for As, Cd, Cr, Hg, Ni, Pb and Pt using this algae material. The key comparison CCQM-K75 was successfully organized. The participating NMIs demonstrated a high level of measurement capabilities and technical competence in analysing nickel and platinum at a low level of concentration in environmental samples such as algae. The between-laboratories reproducibility standard deviation for nickel and platinum was 1.9% and 3.6% respectively, which reflects an excellent agreement of between-laboratories measurement results. The ratio between the bias and its expanded uncertainty for nickel and platinum was below 2.0 for all reported results except in one case. This study was a practical demonstration of a CCQM comparison to use the 'core-capabilities' utilized by participants as a mean of providing evidence for Calibration and Measurement Capabilities (CMC) claims for Ni and Pt. Based on this CCQM international key comparison, the measurement capability of the NMIs which participated in the CCQM-K75 has been demonstrated directly for determination of Pt and Ni

  4. Final report on key comparison CCQM-K100: Analysis of copper in ethanol

    NASA Astrophysics Data System (ADS)

    Zhou, Tao; Kakoulides, Elias; Zhu, Yanbei; Jaehrling, Reinhard; Rienitz, Olaf; Saxby, David; Phukphatthanachai, Pranee; Yafa, Charun; Labarraque, Guillaume; Cankur, Oktay; Can, Süleyman Z.; Konopelko, Leonid A.; Kustikov, Yu A.; Caciano de Sena, Rodrigo; Marques Rodrigues, Janaina; Fonseca Sarmanho, Gabriel; Fortunato de Carvalho Rocha, Werickson; dos Reis, Lindomar Augusto

    2014-01-01

    The increase in renewable sources in the energy matrix of the countries is an effort to reduce dependency on crude oil and the environmental impacts associated with its use. In order to help overcome the lack of widely accepted quality standards for fuel ethanol and to guarantee its competitiveness in the international trade market, the NMIs have been working to develop certified reference materials for bio-fuels and measurement methods. Inorganic impurities such as Cu, Na and Fe may be present in the fuel ethanol and their presence is associated with corrosion and the formation of oxide deposits in some engine parts. The key comparison CCQM-K100 was carried out under the auspices of the Inorganic Analysis Working Group (IAWG) and the coordination of the National Institute of Metrology, Quality and Technology (INMETRO). The objective of this key comparison was to compare the measurement capabilities of the participants for the determination of Cu in fuel ethanol. Ten NMIs participated in this exercise and most of them used the isotopic dilution method for determining the amount of Cu. The median was chosen as key comparison reference value (KCRV). The assigned KCRV for the Cu content was 0.3589 µg/g with a combined standard uncertainty of 0.0014 µg/g. In general, there is a good agreement among the participants' results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. KEY COMPARISON: CCQM-K25: Determination of PCB congeners in sediment

    NASA Astrophysics Data System (ADS)

    Schantz, Michele; Wise, Stephen

    2004-01-01

    Polychlorinated biphenyls (PCBs) consist of 209 possible congeners depending on the substitution of the chlorine atoms around the biphenyl molecule. PCBs have been widely used as industrial fluids, flame retardants, diluents, hydraulic fluids, and dielectric fluids for capacitors and transformers. As a class of compounds, they are environmentally stable and tend to bioaccumulate. Of the 209 possible congeners, approximately 150 congeners have been reported in the environment. Congener-specific PCB methods, which are typically based on gas chromatography (GC) with electron capture detection (ECD) or mass spectrometric (MS) detection, are designed to measure selected priority congeners, but the congeners of interest change with the study and sponsoring agency. A pilot study (CCQM-P17) for the determination of PCB congeners in sediment was organized by NIST and NRC-Canada in 2000. Ten laboratories participated in the pilot study. After discussion and critical review of the data, there was agreement that the pilot study should be followed by a Key Comparison and that the Key Comparison Reference Value (KCRV) should be derived from isotope dilution GC/MS (ID-GC/MS) based methods that had been validated in the Pilot Study. The CCQM-K25 Key Comparison study utilized a sediment sample prepared by mixing known quantities of two sediment materials to simulate a moderately contaminated sample with respect to PCBs. Nine laboratories participated in CCQM-K25 and demonstrated a high level of equivalence in capabilities for determining five PCB congeners (congener numbers 28, 101, 105, 153, and 170) in a moderately contaminated sediment using GC/MS-based methods. The amount of substance concentration for the congeners measured ranged from ~10 ng/g to ~35 ng/g. The relative expanded uncertainties of the KCRVs ranged from 2% to 5%, indicating excellent agreement among the participants that used ID-GC/MS. Results from the one laboratory that used GC/MS with a non-labeled PCB

  6. Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Power, Oliver

    2017-01-01

    This report presents the results of a bilateral comparison of capacitance at 100 pF between the NSAI-NML (Ireland) and the BIPM carried out in 2016. This comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b in which the BIPM is the pilot laboratory. Two 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring rms voltage of 15 V. The results from the NSAI-NML and the BIPM were found to be in relatively good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.85 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. KEY COMPARISON: CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    NASA Astrophysics Data System (ADS)

    Hill, K. D.; Steele, A. G.; Dedikov, Y. A.; Shkraba, V. T.

    2005-01-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 Ω capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L&N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions

  8. Final report on COOMET Vickers PTB/VNIIFTRI key comparison (COOMET.M.H-K1.b and COOMET.M.H-K1.c)

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Herrmann, K.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales of two National Metrology Institutes—PTB and VNIIFTRI. The pilot laboratory was PTB, which was the linking institute with the key comparison reference values of CCM.H-K1. In the key comparison two sets of hardness reference blocks for the Vickers hardness scales HV1 and HV30, each consisting of three hardness reference blocks with the hardness levels 240 HV, 540 HV and 840 HV, are used. The same hardness reference blocks were used previously in the key comparison CCM.H-K1. The measurement results and uncertainty assessments, announced by VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Consensus building for interlaboratory studies, key comparisons, and meta-analysis

    NASA Astrophysics Data System (ADS)

    Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza

    2017-06-01

    Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian

  10. KEY COMPARISON Comparison of the standards of air kerma of the ENEA-INMRI and the BIPM for 137Cs gamma rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Toni, M.; Bovi, M.

    2010-01-01

    A comparison of the standards of air kerma of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI) and of the Bureau International des Poids et Mesures (BIPM) was carried out in 137Cs radiation in 1998. The comparison result, updated for changes in the standards in 2003 and 2009, is 0.9927 (0.0067) and demonstrates that the ENEA-INMRI and BIPM standards are in agreement within the uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. Final report on key comparison COOMET.QM-K36 (Project COOMET 540/UA/11) 'Electrolytic Conductivity 0,5 S/m'

    NASA Astrophysics Data System (ADS)

    Gavrilkin, V.; Prokopenko, L.; Bakovec, N.; Zolotorevich, E.; Suvorov, V.; Ovchinnikov, Yu; Pilishvili, T.; Buleishvili, M.; Zhasanbaeva, B.; Aytzhatova, G.; Ticona, G.; Vyskocil, L.

    2015-01-01

    The COOMET.QM-K36 key comparison 'Electrolytic conductivity: 0.5 S/m' is a comparison in the field of electrolytic conductivity measurements conducted by COOMET and carried out in 2012. It used a solution of KCl in water and the results are connected to those of the CCQM key comparison CCQM-K36.a through common participation of VNIIFTRI (Russia), SMU (Slovakia) and Ukrmetrteststandart (Ukraine). The purpose of this key comparison was to establish the equivalence of measurements of electrolytic conductivity performed at the National Metrology Institutes of COOMET member states for the value of 0.5 S/m. The results can be used to support the CMCs claims over the range of 0.1 S/m to 1.3 S/m. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Final report on APMP.T-K7 key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Tsai, S. F.; White, R.; Tamba, J.; Yamazawa, K.; Ho, M. K.; Tsui, C. M.; Zaid, G.; Achmadi, A.; Gam, K. S.; Othman, H.; Ali, N. M.; Yuan, K. H.; Shaochun, Y.; Liedberg, H.; Yaokulbodee, C.

    2016-01-01

    APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. APMP key comparison for the measurement of air kerma for 60Co (APMP.RI(I)-K1.1)

    NASA Astrophysics Data System (ADS)

    Webb, D. V.; Lee, J.-H.; Budiantari, C. T.; Laban, J.; Saito, N.; Srimanoroth, S.; Khaled, N. E.

    2016-01-01

    The results are reported for an APMP.R(I)-K1.1 comparison that extends the regional comparison of standards for air kerma APMP.R(I)-K1 to several laboratories unable to participate earlier. The comparison was conducted with the goal of supporting the relevant calibration and measurement capabilities (CMCs) planned for publication by the participant laboratories. The comparison was conducted by the pilot laboratory, the Australian Radiation Protection and Nuclear Safety (ARPANSA), Australia, supported by the Institute of Nuclear Energy Research (INER), Taiwan, in a modified ring-shaped arrangement from September 2009 to November 2010, in parallel with an APMP.R(I)-K4 comparison being piloted by the INER. The laboratories that took part in the comparison were the ARPANSA, the Centre of Technology of Radiation Safety and Metrology (PTKMR-BATAN), Indonesia, the Division of Radiation and Medical Devices (DMSC), Thailand, the INER, the National Centre for Radiation Science (NCRS), New Zealand, the National Institute for Standards (NIS), Egypt and the National Metrology Institute of Japan (NMIJ/AIST), Japan. The two primary laboratories, ARPANSA and NMIJ, were chosen as the linking laboratories. Three ionization chambers were used as transfer instruments to be calibrated in terms of air kerma in 60Co radiotherapy beams. The comparison result is based on the ratio between the air kerma calibration coefficients (NK) determined by the participants and the mean of the results of the linking laboratories. The mean comparison ratio was found to be within 0.5 % of the key comparison reference value KCRV. The largest deviation between any two comparison ratios for the three chambers in terms of air kerma was 2.0 %. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE) in terms of the deviations of the results and their associated uncertainties. As a result of this APMP comparison, the BIPM key comparison database (KCDB) should

  14. KEY COMPARISON: CCEM.RF-K9: International comparison of thermal noise standards between 12.4 GHz and 18 GHz (GT-RF/99-1)

    NASA Astrophysics Data System (ADS)

    Allal, Djamel; Achkar, Joseph

    2006-01-01

    An international comparison of thermal noise-power measurements has been carried out among five national metrology institutes between 12.4 GHz and 18 GHz. Four transfer standards were measured. The following national institutes participated: BNM-LCIE (France), NPL (United Kingdom), PTB (Germany), NIST (United States of America) and VNIIFTRI (Russia). The Bureau National de Métrologie-Laboratoire Central des Industries Electriques (France) acted as the pilot laboratory for the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. KEY COMPARISON: Final report of EUROMET Project 696: pH determination of a phthalate buffer

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Charlet, Philippe; Eberhard, Ralf; Karpov, Oleg V.; Philippe, Rachel; Rivier, Cedric; Maximov, Igor; Sudmeier, Uwe

    2005-01-01

    The EUROMET project 696, a trilateral comparison between PTB, Germany, LNE, France and VNIIFTRI, Russia was performed in order to demonstrate and document the capability of the participants to measure the pH of a phthalate buffer by the primary measurement procedure for pH. Good agreement of the reported results was observed. The sample was very similar to the one used in the comparison CCQM-K17. PTB acts as pilot laboratory in CCQM-K17 and in EUROMET 696. This comparison allows one to link the results obtained by LNE to the CCQM-K17 key comparison through the degree of equivalence of PTB. On the other hand, the discrepancy between measured pH values at the VNIIFTRI and PTB for the same type of buffer solution decreased, as compared with a bilateral comparison in 1997. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  16. Results and evaluation of key comparison CCM.P-K12.1 for very low helium flow rates (leak rates)

    NASA Astrophysics Data System (ADS)

    Šetina, Janez; Vičar, Martin; Pražák, Dominik

    2015-01-01

    The Czech Metrology Institute (CMI) took part and failed to prove equivalence in the Key Comparison CCM.P-K12 of helium leak artefacts (leak rates) into vacuum. After identifying and eliminating the cause of the failure, the Institute of Metals and Technology (IMT) of Slovenia, a successful participant in CCM.P-K12, volunteered to serve as pilot and link in a following bilateral comparison of IMT and CMI that obtained designation CCM.P-K12.1 in June 2012. It was decided to perform the comparison with a glass permeation helium leak artefact at nominally 3.10-11 mol/s (7.4.10-7 mbar.L.s-1) at 23 °C. Both the laboratory standards took part in CCM.P-K12 and were considered as primary. The comparison measurements were performed in October 2012. CMI proved equivalence both with IMT and with the reference value of the key comparison CCM.P-K12. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NIS (Egypt) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Helmy, M.; Raouf, A.; Hamed, Heba A. M.; Eliwa Gad, A.

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NIS (Egypt) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NIS, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NIS and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of about 0.72 × 10-6 at 10 pF and about 0.65 × 10-6 at 100 pF. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on the key comparison CCM.P-K4.2012 in absolute pressure from 1 Pa to 10 kPa

    NASA Astrophysics Data System (ADS)

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.66 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A—B—A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 2.5 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2011-01-01

    As a part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2011. Two BIPM Zener diode-based travelling standards (Fluke 732B) were transported by freight to NSAI-NML. At NSAI-NML, the 10 V output EMF of each travelling standard was measured by direct comparison with a group of characterized Zener diode-based electronic voltage standards. At the BIPM, the travelling standards were calibrated before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. KEY COMPARISON: Final Report on EUROMET.T-K3: Regional key comparison of the realisations of the ITS-90 from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Renaot, E.; Hermier, Y.; Valin, M.; Bonnier, G.

    2007-01-01

    This report presents the results of the EUROMET regional key comparison corresponding to CCT-K3 and covering the temperature range from 83.8058 K (triple point of Ar) to 692.77 K (freezing point of Zn). The comparison involved the six NMIs previously involved in CCT-K3 (BNM-INM/CNAM, SMU, IMGC, NMi-VSL, NPL, PTB) and 18 European national laboratories. The comparison was divided into five different loops coordinated by a co-pilot chosen among the laboratories having participated in the CCT-K3 comparison. BNM-INM/CNAM played the role of pilot in establishing the link between the five loops. In each loop, an artefact in the form of a standard platinum resistance thermometer (SPRT) was circulated among the participant laboratories. In order to have sufficient information about the possible drift of the SPRTs, the co-pilots have performed a calibration over the full temperature range at the beginning and at the end of the loop. Each participant laboratory carried out the measurements in agreement with the protocol. After initial measurements of R(tpw) and successful annealing treatment, each calibration consisted of three measurements of R(t) at each fixed point, in separate realizations. Each measurement was followed by a measurement of R(tpw). The order of fixed points was Zn, Sn, In, Ga, Hg, Ar, but if a fixed point was not available, it was omitted. Values of W(t), and their average value, were calculated. The results were reported to the co-pilot and BNM-INM/CNAM, with uncertainty budgets and other specified data. The results of the comparison were analysed by BNM-INM/CNAM. For the sake of clarity, the results are firstly presented loop by loop. In a second step a EUROMET Reference Value (ERV) taking into account the whole comparison was defined. In order to calculate this ERV advantage was taken of the presence of BNM-INM/CNAM in the five loops; the differences between each laboratory's results and BNM-INM's were considered. The participant laboratories decided

  5. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NMISA (South Africa) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Khoza, Michael

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NMISA (South Africa) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NMISA, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NMISA and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of maximum value 0.33 × 10-6 at 10 pF and 0.24 × 10-6 at 100 pF (and 1000 Hz in both cases). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final Report on the Key Comparison CCM.P-K4.2012 in Absolute Pressure from 1 Pa to 10 kPa

    PubMed Central

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. PMID:28216793

  7. KEY COMPARISON: Final report of the CCQM-K56: Ca, Fe, Zn and Cu in whole fat soybean powder

    NASA Astrophysics Data System (ADS)

    Liandi, Ma; Qian, Wang

    2010-01-01

    The CCQM-K56 key comparison was organized by the Inorganic Analysis Working Group (IAWG) of CCQM as a follow-up to completed pilot study CCQM-P64 to test the abilities of national metrology institutes to measure the amount content of nutritious elements in whole fat soybean powder. A pilot study CCQM-P64.1 was conducted in parallel with this key comparison. The National Institute of Metrology (NIM), P. R. China, acted as the coordinating laboratory. Eleven NIMs participated in CCQM-K56. Four elements - Ca, Fe, Zn and Cu - in different concentration levels have been studied. Different measurement methods (IDMS, ICP-MS, ICP-OES, AAS and INAA) and the microwave digestion method were used. The agreement of the results of CCQM-K56 is very good, and obviously better than that of the original P64. It shows that the capability of all of the participants had been promoted from the original pilot study to this key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. KEY COMPARISON: Final report on CCEM key comparison CCEM.RF-K10.CL (GT-RF/99-2) 'Power in 50 Ω coaxial lines, frequency: 50 MHz to 26 GHz' measurement techniques and results

    NASA Astrophysics Data System (ADS)

    Janik, Dieter; Inoue, T.; Michaud, A.

    2006-01-01

    This report summarizes the results and the measuring methods of an international key comparison between twelve national metrology institutes (NMIs) and is concerning the calibration factor of RF power sensors in the coaxial 3.5 mm line for frequencies up to 26 GHz. Two RF power travelling standards fitted with male PC 3.5 mm connectors were measured at seven frequencies. The following NMIs participated: NMIJ (Japan), NRC (Canada), NIST (USA), METAS (Switzerland), CSIR-NML (South Africa), NMIA (Australia), NPL (UK), SiQ (Slovenia), IEN (Italy), VNIIFTRI (Russian Federation), SPRING (Singapore) and PTB (Germany), as the pilot laboratory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Final report of CCAUV.V-K3: key comparison in the field of acceleration on the complex charge sensitivity

    NASA Astrophysics Data System (ADS)

    Qiao, Sun; Lifeng, Yang; Bartoli, Claire; Veldman, Ian; Ripper, Gustavo P.; Bruns, Thomas; Rask Licht, Torben; Kolasa, Joanna; Hof, Christian; Silva Pineda, Guillermo; Dickinson, Laurence; Ota, Akihiro; Cheung, Wan Sup; Yankovsky, Alexander; Shan, Cui

    2017-01-01

    This is the final report for CIPM key comparison CCAUV.V-K3 in the area of 'vibration' (quantity of acceleration). The aim of this comparison was to measure the voltage sensitivity of one accelerometer standard set with primary means at 27 frequencies from 0.1 Hz to 40 Hz. Fourteen Metrology Institutes from five RMOs have participated in the comparison with National Institute of Metrology, P.R. China as pilot lab and Laboratoire National de Métrologie et d'Essais and National Metrology Institute of South Africa as co-pilot labs. One quartz-flexure servo accelerometer of single-ended type and a signal conditioner was circulated among the participants. All but one of the participating laboratories provided their calibration results, which were mostly consistent within their declared expanded uncertainties for magnitude results. Only two participants failed to contribute to the KCRV values calculated for five frequencies. For phase shift, three participants could not contribute to the calculation of the KCRV values in a total of sixteen frequencies. This first low-frequency vibration key comparison revealed the current calibration capabilities of the fourteen participants of five RMOs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out in February and March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_4 (Z4) and BIPM_5 (Z5), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 10 March 2014. UNML - UBIPM = -0.64 µV uc = 1.35 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to

  11. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the SMD (Belgium) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, Benjamin; Fletcher, Nick; Vlad, Dana

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the SMD (Belgium) and the BIPM carried out in 2017. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the SMD, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13.b (for 10 kΩ). The results from the SMD and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.080 × 10-6 for 1 Ω and 0.068 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIMT (Thailand) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Khumthukthit, N.; Jassadajin, C.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NIMT (Thailand) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NIMT and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.20 × 10-6 for 1 Ω and 0.74 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Report of the key-comparison of spectral diffuse reflectance (EURAMET.PR-K5) (Ref. 619)

    NASA Astrophysics Data System (ADS)

    Andor, György; Gál, Péter

    2018-01-01

    This report details the final results of the EURAMET comparison on regular spectral transmittance carried out between 2006 and 2016. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 780 nm at 20 nm increment. We used a star type comparison: first the participants sent their samples to the pilot, than the pilot measured all the samples of the participants and sent them back. The participants measured the samples and sent them to the pilot for control measurement. Six standards were used as reference standards in order to maintain the scale during the comparison. These were three samples of BCR-406 opal glasses (BCR 30506; BCR 30303; BCR 30704), an MC20 Russian opal glass (MC 4777) and two samples made of pressed halon (polytetrafluoroethylene) powder (halon 2007A; halon 2007C). These six samples were designated as the Comparison reference standards. The diffuse reflectance was initially measured on the OMH (BFKH) absolute reflectometer. The link to the CCPR-K5 results was BFKH, and the check on BFKH was the PTB results who also participated in the CCPR-K5 comparison. The participants were GUM, INM, LNE, METAS, BFKH, PTB, SP. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report on SIM Regional Key Comparison SIM.L-K1.2007: Calibration of gauge blocks by optical interferometry

    NASA Astrophysics Data System (ADS)

    Colín, C.; Viliesid, M.; Chaudhary, K. P.; Decker, J.; Dvorácek, F.; Franca, R.; Ilieff, S.; Rodríguez, J.; Stoup, J.

    2012-01-01

    This Key Comparison of gauge blocks (GB) calibration by optical interferometry was carried out to support this Calibration and Measurement Capability (CMC) of the National Measurement Institutes (NMI) from the SIM Region for this specific service and for those that rely on this kind of technique as required by the Mutual Recognition Arrangement (MRA). It provides evidence of the participant's technical competence and supports the uncertainties they state in their CMC. It is a Regional Key Comparison and should be linked to the upper level corresponding comparison CCL-K1. The comparison had nine participants, five from the SIM Region—NRC-CNRC, Canada; NIST, USA; CENAM, Mexico; INMETRO, Brazil; and INTI, Argentina— and four from other regions—CMI, Czech Rep.; CEM, Spain; NPLI, India; and NMISA South Africa. It included the circulation of fourteen GB—seven steel GB and seven ceramic GB. The circulation of the artifacts started on 2007-11-01 and ended on 2010-04-25. Some additional time was required to publish the results as the same artifacts were used thereafter for comparison SIM.L-S6, Calibration of GB by mechanical comparison, and the results could not be disclosed until the participants of the second circulation loop had sent their results. The final report of this comparison was sent out for review in May 2012 and the final version was approved in August 2012. The behavior of the artifacts throughout the circulation was good and therefore the results obtained were judged technically valid. The reference value was taken as arithmetic mean of the largest subset of consistent results. Most of participates obtained results in good agreement with the reference values with a few exceptions mentioned in the report. The corresponding NMIs are responsible for identifying the causes and taking corrective action. This makes the present comparison exercise valid to support the CMC claims of the participants in GB calibration by optical interferometry. Main text. To

  15. Final report on the key comparison of hydrocarbon liquid flow: CCM.FF-K2.2015

    NASA Astrophysics Data System (ADS)

    Shimada, T.; Bittner-Rohrhofer, K.; Medina López, V. J.; Arias, R.; Su, C.-M.; Chen, I.-C.; Ribere, F.; Rowan, L.; Dignan, S.

    2016-01-01

    Seven laboratories: BEV (Austria), CENAM (Mexico), CMS (Chinese-Taipei), LNE-TRAPIL (France), NEL (United Kingdom), NMIA (Australia), and the pilot lab NMIJ (Japan), participated in the key comparison CCM.FF-K2.2015 for hydrocarbon flow measurement. A screw type positive displacement flow meter was selected as a transfer standard. The calibration stability of the transfer standard was evaluated from repeated measurements by NMIJ and showed standard reproducibility of 0.0035 %. The transfer standard was also thoroughly tested for sensitivity to temperature, viscosity, pressure, and other effects. The uncertainty due to the transfer standard of 0.0080 % was less than the quoted uncertainties of the participants. The key comparison reference values (KCRVs) at Reynolds number of 70 000 and 300 000 were obtained as the weighted mean from the calibration results, and the KCRV at Reynolds number of 100 000 was obtained as the median by using the Monte Carlo method according to Cox's procedure B, since the consistency check at Reynolds number of 100 000 failed at the 95 % confidence level. All participant results selected to determine the KCRVs have En values which show consistency with the evaluated KCRVs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the BIM (Bulgaria) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Tenev, A.; Hadzhistoykova, R.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the BIM (Bulgaria) and the BIPM carried out in 2013. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.30 × 10-6 at 10 kΩ and in reasonable agreement for 1 Ω with a relative difference of -0.18 × 10-6 with a relative expanded uncertainty of 0.17 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the CMI (Czech Republic) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Kučera, J.; Chrobok, P.; Vo&jacute; čko&vacute; , L.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the CMI (Czech Republic) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the CMI and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.046 × 10-6 for 1 Ω and 0.034 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Power, O.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.16 × 10-6 for 1 Ω and 0.42 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. KEY COMPARISON: Final report on CCQM-K57: Chemical composition of clay

    NASA Astrophysics Data System (ADS)

    Salas, Antonio; Ramírez, Estele

    2009-01-01

    After the successful completion of the pilot study, CCQM-P65 [1], the Inorganic Analysis Working Group of CCQM agreed to conduct key comparison CCQM-K57, Chemical composition of clay, in Paris, April 2006. The natural mass fraction levels of five elements—Si, Ca, Fe, Al and Mg—were measured and reported as oxides in clay. Six national metrology institutes participated in CCQM K57, and CENAM (Querétaro, Mexico) coordinated. The methods employed were isotope dilution mass spectrometry (IDMS), inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-optical emission spectrometry (ICP-OES) using the dehydration method and condensation method, gravimetric analysis, neutron activation analysis (NAA), prompt gamma activation analysis (PGAA) and x-ray fluorescence spectrometry (XRF) with the reconstitution method and external calibration. This final report presents the capability of the participant institutes, based on the KCRV, which was approved at the IAWG spring meeting in 2008, and the equivalence statements regarding the KCRV, approved at its autumn meeting. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in January and February 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM7 (Z7) and BIPM9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V, at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 31 of January 2016. UNML - UBIPM = + 0.22 μV uc = 1.35 μV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Power, O.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in February and March 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMC (ZC), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final resultof the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V,at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 24 February 2015. UNML - UBIPM = - 0.82 mV; uc = 1.35 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. KEY COMPARISON: Results of the APMP Pressure key comparison APMP.M.P-K1c in gas media and gauge mode from 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, A. K.; Woo, Sam Yong; Fitzgerald, Mark; Man, John; Ooiwa, Akira; Jescheck, M.; Jian, Wu; Fatt, Chen Soo; Chan, T. K.; Moore, Ken; El-Tawil, Alaaeldin A. E.

    2003-01-01

    This report summarizes the results of a regional key comparison (APMP-IC-2-97) under the aegis of the Asia Pacific Metrology Program (APMP) for pressure measurements in gas media and in gauge mode from 0.4 MPa to 4.0 MPa. The transfer standard was a pressure-balance with a piston-cylinder assembly with nominal effective area 8.4 mm2 (V-407) and was supplied by the National Metrology Institute of Japan [NMIJ]. Ten standard laboratories from the APMP region with one specially invited laboratory from the EUROMET region, namely Physikalisch-Technische Bundesanstalt (PTB), Germany, participated in this comparison. The comparison started in October 1998 and was completed in May 2001. The pilot laboratory prepared the calibration procedure [1] as per the guidelines of APMP and the International Bureau of Weights and Measures (BIPM) [2-4]. Detailed instructions for performing this key comparison were provided in the calibration protocol [1] and the required data were described in: (1) Annex 3 - characteristics of the laboratory standards, (2) Annex 4 - the effective area (A'p'/mm2) (the prime indicates values based on measured quantities) at 23°C of the travelling standard as a function of nominal pressure (p'/MPa) (five cycles both increasing and decreasing pressures at ten pre-determined pressure points) and (3) Annex 5 - the average effective area at 23°C (A'p'/mm2) obtained for each pressure p'/MPa with all uncertainty statements. The pilot laboratory processed the information and the data provided by the participants for these three annexes, starting with the information about the standards as provided in Annex 3. Based on this information, the participating laboratories are classified into two categories: (I) laboratories that are maintaining primary standards, and (II) laboratories that are maintaining standards loosely classified as secondary standards with a clear traceability as per norm of the BIPM. It is observed that out of these eleven laboratories, six

  3. SUPPLEMENTARY COMPARISON: Final report on APMP.PR-S1.1: Bilateral comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Huang, Xuebo

    2009-01-01

    In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. Final report on key comparison EURAMET.M.P-K13 in the range 50 MPa to 500 MPa of hydraulic gauge pressure

    NASA Astrophysics Data System (ADS)

    Kocas, I.; Sabuga, W.; Bergoglio, M.; Eltaweel, A.; Korasie, C.; Farar, P.; Setina, J.; Waller, B.; Durgut, Y.

    2015-01-01

    The regional key comparison EURAMET.M.P-K13 for pressure measurements in liquid media from 50 MPa to 500 MPa was piloted by the TÜBİTAK UME Pressure Group Laboratories, Turkey. The transfer standard was a DH-Budenberg pressure balance with a free deformation piston-cylinder unit of 2 mm2 nominal effective area. Six laboratories from the EURAMET region, namely PTB, INRIM, SMU, IMT, NPL and UME, and two laboratories from the AFRIMETS region, NIS and NMISA participated in this comparison. Participant laboratories and countries are given in the bottom of the page. PTB participated in this comparison to provide a link to corresponding 500 MPa CCM key comparison CCM.P-K13. The results of all participants excepting NMISA and NPL were found to be consistent with the reference value of the actual comparison and of CCM.P-K13 within their claimed uncertainties (k = 2), at all pressures. Compared in pairs all laboratories with exception of NPL and NMISA demonstrate their agreement with each other within the expanded uncertainties (k = 2) at all pressures. The results are therefore considered to be satisfactory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. International comparison CCQM-K101: oxygen in nitrogen—a track B comparison and that the matrix contains argon

    NASA Astrophysics Data System (ADS)

    Zhou, Z.; Han, Q.; Wang, D.; Macé, T.; Kipphardt, H.; Maiwald, M.; Tuma, D.; Uehara, S.; Akima, D.; Shimosaka, T.; Jung, J.; Oh, S.-H.; van der Veen, A.; van Wijk, J. I. T.; Ziel, P. R.; Konopelko, L.; Valkova, M.; Mogale, David M.; Botha, A.; Brewer, P.; Murugan, A.; Doval Minnaro, M.; Miller, M.; Guenther, F.; Kelly, M. E.

    2016-01-01

    This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Bilateral key comparison CCM.P-K3.1 for absolute pressure measurements from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Fedchak, J. A.; Bock, Th; Jousten, K.

    2014-01-01

    This report describes the bilateral key comparison CCM.P-K3.1 between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt (PTB) for absolute pressure in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. This comparison was a follow-up to the comparison CCM.P-K3. Two ionization gauges and two spinning rotor gauges (SRGs) were used as the transfer standards for the comparison. The SRGs were used to compare the standards at a pressure of 9 × 10-4 Pa and to normalize the ionization gauge readings. The two ionization gauges were used to compare the standards in the pressure range of from 3 × 10-6 Pa to 3 × 10-4 Pa. Both laboratories used dynamic expansion chambers as standards in the comparison. The two labs showed excellent agreement with each other and with the CCM.P-K3 key comparison reference value (KCRV) over the entire range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Chayramy, R.; Solve, S.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from January to February 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_8 (Z8) and BIPM_9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 February 2013. UNML - UBIPM = -0.63 µV uc = 1.31 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according

  8. Key comparison BIPM.RI(I)-K9 of the absorbed dose to water standards of the PTB, Germany and the BIPM in medium-energy x-rays

    NASA Astrophysics Data System (ADS)

    Burns, D. T.; Kessler, C.; Büermann, L.; Ketelhut, S.

    2018-01-01

    A key comparison has been made between the absorbed dose to water standards of the PTB, Germany and the BIPM in the medium-energy x-ray range. The results show the standards to be in general agreement at the level of the standard uncertainty of the comparison of 9 to 11 parts in 103. The results are combined with those of a EURAMET comparison and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the SMU, Slovakia and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    A key comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0042 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. KEY COMPARISON: Final report on CCPR K1-a: Spectral irradiance from 250 nm to 2500 nm

    NASA Astrophysics Data System (ADS)

    Woolliams, Emma R.; Fox, Nigel P.; Cox, Maurice G.; Harris, Peter M.; Harrison, Neil J.

    2006-01-01

    The CCPR K1-a key comparison of spectral irradiance (from 250 nm to 2500 nm) was carried out to meet the requirements of the Mutual Recognition Arrangement by 13 participating national metrology institutes (NMIs). Because of the fragile nature of the tungsten halogen lamps used as comparison artefacts, the comparison was arranged as a star comparison with three lamps per participant. NPL (United Kingdom) piloted the comparison and, by measuring all lamps, provided a link between participants' measurements. The other participants were BNM-INM (France), CENAM (Mexico), CSIRO (Australia), HUT (Finland), IFA-CSIC (Spain), MSL-IRL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NRC (Canada), PTB (Germany) and VNIIOFI (Russian Federation). Before the analysis was completed and the results known, the pilot discussed with each participant which lamp measurements should be included as representative of their comparison. As a consequence of this check, at least one measurement was excluded from one third of the lamps because of changes due to transportations. The comparison thus highlighted the difficulty regarding the availability of suitable transfer standards for the dissemination of spectral irradiance. The use of multiple lamps and multiple measurements ensured sufficient redundancy that all participants were adequately represented. In addition, during this pre-draft A phase all participants had the opportunity to review the uncertainty budgets and methods of all other participants. This new process helped to ensure that all submitted results and their associated uncertainties were evaluated in a consistent manner. The comparison was analysed using a model-based method which regarded each lamp as having a stable spectral irradiance and the measurements made by an NMI as systematically influenced by a factor that applies to all that NMI's measurements. The aim of the analysis was to estimate the systematic factor for each NMI. Across the

  11. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays.

    PubMed

    Burns, D T; Kessler, C; O'Brien, M; Minniti, R

    2012-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x-ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 10 3 , except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database.

  12. On-site comparison of Quantum Hall Effect resistance standards of METAS and the BIPM: Ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Mortara, Alessandro; Jeanneret, Blaise

    2018-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Federal Institute of Metrology METAS (Switzerland) and of the Bureau International des Poids et Mesures (BIPM) was made in December 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 5 parts in 1010 with a relative combined standard uncertainty uc = 23 × 10‑10. Scaling from 100 Ω to 10 kΩ has also been addressed through the measurement of a 10000 Ω/100 Ω ratio. The measurements carried out agreed to 2 parts in 1010 with a relative combined standard uncertainty uc = 19 × 10‑10. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays

    PubMed Central

    Burns, D T; Kessler, C; O’Brien, M; Minniti, R

    2017-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x–ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 103, except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. PMID:28966399

  14. Report on key comparison COOMET.AUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Dobrowolska, D.; Kosterov, A.

    2016-01-01

    This is the final report for regional key comparison COOMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Two laboratories—Central Office of Measures (GUM)—the national metrology institute for Poland and the State Enterprise Scientific-Research Institute for Metrology of Measurement and Control Systems (DP NDI Systema)— the designated institute for acoustics in Ukraine took part in this comparison with the GUM as a pilot. One travelling type LS1P microphone was circulated to the participants and results in the form of regular calibration certificates were collected. The results of the DP NDI Systema obtained in this comparison were linked to the CCAUV.A-K5 key comparison through the joint participation of the GUM. The degrees of equivalence were computed for DP NDI Systema with respect to the CCAUV.A-K5 key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Key comparison SIM.EM.RF-K5b.CL: scattering coefficients by broad-band methods, 2 GHz-18 GHz — type N connector

    NASA Astrophysics Data System (ADS)

    Silva, H.; Monasterios, G.

    2016-01-01

    The first key comparison in microwave frequencies within the SIM (Sistema Interamericano de Metrología) region has been carried out. The measurands were the S-parameters of 50 ohm coaxial devices with Type-N connectors and were measured at 2 GHz, 9 GHz and 18 GHz. SIM.EM.RF-K5b.CL was the identification assigned and it was based on a parent CCEM key comparison named CCEM.RF-K5b.CL. For this reason, the measurements standards and their nominal values were selected accordingly, i.e. two one-port devices (a matched and a mismatched load) to cover low and high reflection coefficients and two attenuators (3dB and 20 dB) to cover low and high transmission coefficients. This key comparison has met the need for ensuring traceability in high-frequency measurements across America by linking SIM's results to CCEM. Six NMIs have participated in this comparison which was piloted by the Instituto Nacional de Tecnología Industrial (Argentina). A linking method of multivariate values was proposed and implemented in order to allow the linking of 2-dimensional results. KEY WORDS FOR SEARCH Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Report to the CCT on COOMET comparison COOMET.T-K3.1 (previously COOMET.T-S1): Key regional comparison of the national standards of temperature in the range from the triple point of water to the freezing point of zinc

    NASA Astrophysics Data System (ADS)

    Pokhodun, A. I.

    2010-01-01

    In the framework of the CIPM MRA, a first COOMET comparison "Comparison of the ITS-90 realizations in the range from 0.01 °C to 429.7485 °C (from the triple point of water to the freezing point of zinc)", registered in the KCDB under the identifier "COOMET.T-K3", was carried out in 2005-2007. Four national metrology institutes took part in this comparison: VNIIM (Russian Federation), SMU (Slovakia), BelGIM (Republic of Belarus) and NSC IM (Ukraine), and two of them (VNIIM and SMU) ensured the linkage with key comparisons CCT-K3 and CCT-K4, in order to disseminate the metrological equivalence to the measurement standards of NSC IM and BelGIM. NSC IM, however, had to withdraw its results, and at the meeting of Technical Committee T-10 of COOMET it was decided to carry out a supplementary bilateral comparison between VNIIM and the NSC IM for realization of the ITS-90 in the same range of temperature. This was registered in the KCDB under the identifier COOMET.T-S1 and measurements were performed in 2008-2009. From the results presented in this report, it is possible to draw the conclusion that the COOMET supplementary comparison COOMET.T-S1 demonstrates the CMC uncertainties claimed by the NSC IM for the melting point of gallium 0.236 mK (k = 2), and the freezing points of indium 1.040 mK (k = 2), tin 0.858 mK (k = 2) and zinc 0.944 mK (k = 2). In September 2012 the Working Group on key Comparisons (WG 7) of the CCT upgraded this comparison to a COOMET key comparison of the 'CCT-K3' type. It is now identified as COOMET.T-K3.1. In April 2013 this report was superseded by item 03006 in the Technical Supplement of 2013. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2012-01-01

    As part of the on-going BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from February to March 2012. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_C (ZC) and BIPM_D (ZD), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson voltage standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 February 2012. UNML - UBIPM = +0.83 µV, uc = 1.35 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. The final result is impacted by the anomalous offset between the NSAI-NML results for the two transfer standards. The reason for this offset hasn't been determined. However, the difference remains within the total combined standard uncertainty. Therefore, the comparison result shows that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of

  18. International comparison CCQM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Oudwater, Rutger J.; Fioravante, Andreia L.; Augusto, Cristiane R.; Coutinho Brum, Mariana; Uehara, Shinji; Akima, Dai; Bae, Hyun Kil; Kang, Namgoo; Woo, Jin-Chun; Liaskos, Christina E.; Rhoderick, George C.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique; Brewer, Paul J.; Brown, Andrew S.; Bartlett, Sam; Downey, Michael L.; Konopelko, L. A.; Kolobova, A. V.; Pankov, A. A.; Orshanskaya, A. A.; Efremova, O. V.

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare primary standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as a track A key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities using the flexible scheme, and for propane under the default scheme. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results but one are within +/- 0.2 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.; Rujirat, N.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device. Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 2.6 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Final report on APMP.T-K7.1 key comparison of water triple point cells, bilateral NMIJ-VMI

    NASA Astrophysics Data System (ADS)

    Yamazawa, Kazuaki; Nakano, Tohru; Thanh Binh, Pham

    2018-01-01

    APMP.T-K7.1, was held from July 2014 to May 2015 to compare the national realizations of the water triple point between NMIJ (Japan) and VMI (Vietnam). To reach the objective, VMI sent a transfer cell to NMIJ and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the NMIJ and at the VMI, and aims to link the results of APMP.T-K7.1 to APMP.T-K7 and CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. International comparison CCQM-K111.1—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capability of preparing Primary Standard gas Mixtures (PSMs), performing the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this subsequent key comparison is classified as a track B key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities for propane under the default scheme. The artefact was a binary mixture of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The result of the participating laboratory is consistent with the key comparison reference value within the respective expanded uncertainties and deviates less than 0.1 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Social Comparison Processes in Organizations

    ERIC Educational Resources Information Center

    Greenberg, Jerald; Ashton-James, Claire E.; Ashkanasy, Neal M.

    2007-01-01

    We systematically analyze the role of social comparison processes in organizations. Specifically, we describe how social comparison processes have been used to explain six key areas of organizational inquiry: (1) organizational justice, (2) performance appraisal, (3) virtual work environments, (4) affective behavior in the workplace, (5) stress,…

  3. Comparisons between Intel 386 and i486 microprecessors

    NASA Technical Reports Server (NTRS)

    Liu, Yuan-Kwei

    1989-01-01

    A quick and preliminary comparison is made between the Intel 386 and i486 microprocessors. The following topics are discussed: the i486 key elements, comparison of instruction set architecture, the i486 on-chip cache characteristics, the i486 multiprocessor support, comparison of performance, comparison of power consumption, comparison of radiation hardening potential, and recommendations for the Space Station Freedom (SSF) Data Management System (DMS).

  4. Bilateral comparison of 1 V and 10 V standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Simionescu, M.; Cîrneanu, L.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Institut National de Metrologie (INM), Bucharest, Romania, was carried out from August to October 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_8 (Z8), were transported by freight to INM. At INM, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at INM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by INM, at the level of 1.018 V and 10 V, at INM, UINM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 6 September 2013. UINM - UBIPM = -0.014 µV uc = 0.051 µV, at 1 V UINM - UBIPM = -0.43 µV uc = 0.34 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at INM, based on KJ-90, and the uncertainty related to the comparison. These are satisfactory results. The comparison results show that the voltage standards maintained by INM and the BIPM were equivalent, within the comparison uncertainty, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual

  5. Key comparison BIPM.RI(I)-K5 of the air-kerma standards of the SMU, Slovakia and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    The first direct comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0051 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the MKEH, Hungary and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Machula, G.

    2018-01-01

    A comparison of the standards for air kerma of the Hungarian Trade Licensing Office (MKEH), Hungary and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in March 2016. The comparison result, evaluated as a ratio of the MKEH and the BIPM standards for air kerma, is 1.0047 with a combined standard uncertainty of 1.9 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2.6 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. CCQM-K104 key comparison (avermectin B1a) on the characterization of organic substances for chemical purity

    NASA Astrophysics Data System (ADS)

    Dai, Xinhua; Zhang, Wei; Li, Hongmei; Huang, Ting; Li, Mengwan; Quan, Can; Zhang, Qinghe; Davies, Stephen R.; Warren, John; Lo, Man-fung; Kakoulides, Elias; Ceyhan Gören, Ahmet; Marbumrung, Sornkrit; Pfeifer, Dietmar; Ün, İlker; Gündüz, Simay; Yilmaz, Hasibe; Kankaew, Pornhatai; Sudsiri, Nittaya; Shearman, Kittiya; Pookrod, Preeyaporn; Polzer, Joachim; Radeck, Wolfgang

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K104, was coordinated by the National Institute of Metrology (NIM). The comparison was designed to demonstrate a laboratory's performance in determining the mass fraction of the main component in a complex high purity organic material. Nine NMIs or DIs participated in the comparison. Eight participants reported their results. An additional impurity was resolved from the avermectin B1a peak and was tentatively identified as an unknown impurity by NMIA (National Measurement Institute (Australia)). It was subsequently identified by NIM as a diastereoisomer of avermectin B1a at the C-26 position. Final reference value (KCRV) = 924.63 mg/g, with uncertainty (k=1) = 3.89 mg/g, and expanded uncertainty = 8.97 mg/g. The degrees of equivalence with the avermectin B1a KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of high structural complexity (relative molecular mass range of 500 Da -1000 Da and low polarity (-log KOW <= -2). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Report of the key comparison CCQM-K108 determination of arsenic species, total arsenic and cadmium in brown rice flour

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shinichi; Kotzeva, Boriana; Kakoulides, Elias; Sxoina, Vasiliki; Fung, W. H.; Choi, Y. Y.; Yau, H. P.; Tsoi, Y. T.; Lee, C. L.; Kong, M. F.; Shin, Richard; Juan, Wang; Sin Yee, Ng; Uribe, Christian; Marques Rodrigues, Janaína; Caciano de Sena, Rodrigo; Silva Dutra, Emily; Bergamaschi, Luigi; Giordani, Laura; D'Agostino, Giancarlo; Valiente, Liliana; Horvat, Milena; Jacimovic, Radojko; Oduor Okumu, Tom; Kang'Iri, Jacqueline; Owiti Orwa, Tabitha; Chao, Wei; Jingbo, Chao; Taebunpakul, Sutthinun; Yafa, Charun; Kaewkhomdee, Nattikarn; Chailap, Benjamat; Pharat, Yanee; Phukphattanachai, Pranee; Turk, Gregory C.; Long, Stephen; Murphy, K. E.; Davis, Clay; Ellisor, Michael; Merrick, Jeffrey; White, Ian; Saxby, David; Linsky, S. M.; Barzev, A.; Botha, A.

    2015-01-01

    The CCQM-K108 key comparison was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes (NMIs) or designated institutes (DIs) to measure the mass fractions of arsenic species, total arsenic and cadmium in brown rice flour. The National Metrology Institute of Japan (NMIJ) acted as the coordinating laboratory. The participants used different measurement methods, though most of them used inductively coupled plasma mass spectrometry (ICP-MS) or isotope-dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) for Cd and ICP-MS for total arsenic. Regarding arsenic speciation, all participants used ICP-MS coupled with liquid chromatography (LC). Accounting for relative expanded uncertainty, comparability of measurement results for each of total arsenic and cadmium was successfully demonstrated by the participating NMIs or DIs for the measurement of the measurand at the level of less than 0.5 mg/kg. Regarding arsenic species (inorganic arsenic and dimethylarsinic acid (DMAA)), there was, however, a measurement problem still to be solved and that part of CCQM-K108 will be repeated. It is expected that arsenic, cadmium and other metals at mass fractions greater than approximately 0.1 mg/kg in rice flour can be determined by each participant using the same technique(s) employed for this key comparison to achieve similar uncertainties mentioned in the present report. Furthermore, the results of this key comparison can be utilised along with the IAWG core capability approach. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Comparison of the Josephson Voltage Standards of the DMDM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Cincar Vujovic, T.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Directorate of Measures and Precious Metals (DMDM), Belgrade, Serbia, was carried out in June 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the DMDM using its Josephson standard with its own measuring device. Option A required the DMDM to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. Since no sufficiently stable voltage could be achieved in this configuration, a digital detector was used. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 1.5 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Subsequent bilateral comparison to CCT-K3, CIPM key comparison CCT-K3.1: Comparison of standard platinum resistance thermometers at the triple point of water (T = 273.16 K) and at the melting point of gallium (T = 302.9146 K)

    NASA Astrophysics Data System (ADS)

    Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.

    2011-01-01

    A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. International comparison Euramet.QM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    Wouter van der Hout, J.; van der Veen, Adriaan M. H.; Ziel, Paul R.; Kipphardt, Heinrich; Tuma, Dirk; Maiwald, Michael; Fernández, Teresa E.; Gómez, Concepción; Cieciora, Dariusz; Ochman, Grzegorz; Dias, Florbela; Silvino, Victor; Macé, Tatiana; Sutour, Christophe; Marioni, Fabrice; Ackermann, Andreas; Niederhauser, Bernhard; Fükő, Judit; Büki, Tamás; Nagyné Szilágyi, Zsófia; Tarhan, Tanıl; Engin, Erinç

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within +/- 1 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. On-site comparison of Quantum Hall Effect resistance standards of the CMI and the BIPM: ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Kučera, Jan; Vojáčková, Lucie

    2017-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Czech Metrology Institute (CMI) and of the Bureau International des Poids et Mesures (BIPM) was made in April 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 6 parts in 1010 with a relative combined standard uncertainty uc = 25 × 10-10. Measurements of 10000 Ω/100 Ω and 100 Ω/1 Ω ratios agreed to 11 parts in 1010 with uc = 22 × 10-10 and to 33 parts in 1010 with uc = 32 × 10-10, respectively. The influence of the current reversal time has been systematically investigated in order to take into account possible errors due to the Peltier effect, which may be particularly large in 1 Ω standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. KEY COMPARISON: EUROMET.M.D-K4/EUROMET Project 702: Comparison of the calibrations of high-resolution hydrometers for liquid density determinations

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Malengo, A.; Vámossy, C.; Bettin, H.; Toth, H.; do Céu Ferreira, M.; Gosset, A.; Madec, T.; Heinonen, M.; Buchner, C.; Lenard, E.; Spurny, R.; Akcadag, U.; Domostroeva, N.

    2008-01-01

    The main objective of the EUROMET project 702 was to compare the extent of comparability among eleven participating European national metrology institutes (INRIM (IT), OMH (HU), PTB (DE), BEV (AT), IPQ (PT), LNE (FR), MIKES (FI), GUM (PL), SMU (SK), UME (TR) and VNIIM (RU)) in performing calibrations of high-resolution hydrometers for liquid density determination in the range between 600 kg m-3 and 1300 kg m-3. By means of two groups of four similar transfer standards of excellent metrological characteristics, the participating laboratories were initially divided into two groups (petals) linked by the three density laboratories of INRIM, OMH and PTB. The results of the participating laboratories have been analyzed in this report and a good agreement was found between the results provided by most of the participants. These results allowed also determination of the degrees of equivalence of each NMI participating with the EUROMET_key comparison reference values (EU_KCRV); they will provide a basis for the review of the Calibration Measurement Capabilities (CMC) entries on hydrometer calibration, and they allowed the degree of equivalence between pairs of NMIs to be established. The Istitituto Nazionale di Ricerca Metrologica (INRIM), Italy, formerly IMGC-CNR, coordinated the project. Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Bilateral Comparison of 1 V and 10 V Standards between the NIS (Egypt) and the BIPM, August to September 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Abdel Mageed, Hala M.; Aladdin, Omar M.; Raouf, M. Helmy A.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMB (ZB) and BIPMC (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, UNIS, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 7 September 2014. UNIS - UBIPM = 0.09 µV uc = 0.08 µV, at 1 V UNIS - UBIPM = 0.22 µV uc = 0.14 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM

  15. Key comparison BIPM.RI(I)-K5 of the air kerma standards of the ININ, Mexico and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D. T.; Alvarez Romero, J. T.; De la Cruz Hernández, D.; Cabrera Vertti, M. R.; Tovar-Muñoz, V. M.

    2015-01-01

    A direct comparison of the standards for air kerma of the Instituto Nacional de Investigaciones Nucleares (ININ), Mexico, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in February 2015. The comparison result, evaluated as a ratio of the ININ and the BIPM standards for air kerma, is 1.0048 with a combined standard uncertainty of 2.0 × 10-3. The results are analysed and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Report on NIM-NMC bilateral comparison: SPRT calibration comparison from -190°C to 420°C

    NASA Astrophysics Data System (ADS)

    Sun, Jianping; Ye, Shaochun; Wang, Li; Zhang, Jintao; Kho, Haoyuan

    2016-01-01

    A bilateral comparison of local realization of the International temperature scale of 1990 (ITS-90) between National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from -190°C to 420°C. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key comparison 3 (CCT-K3) and facilitate the NMC's Calibration and measurement capabilities (CMCs) submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme (APMP) in 2009, and registered in the Key Comparison Database (KCDB) in 2010 as CCT-K3.2. NMC supplied two 25 Ω fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn and Zn fixed points, while the other one was used at the Ar and Hg fixed point. NMC measured them before and after NIM measurement. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 Average Reference Value (ARV) using NIM as a link are reported with expanded uncertainties at each measured fixed point. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report on key comparison CCAUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Avison, Janine; Barham, Richard

    2014-01-01

    This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. SUPPLEMENTARY COMPARISON: APMP.PR-S1 comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Xu, Gan; Huang, Xuebo; Liu, Yuanjie

    2007-01-01

    APMP.PR-S1, a supplementary comparison of irradiance responsivity of UVA detectors, was carried out among seven national metrology institutes piloted by SPRING Singapore from 2003 to 2005. Two quantities, the narrow band UV (365 nm ± 5 nm) irradiance responsivity and the broad band UVA (315 nm-400 nm) irradiance responsivity of the transfer detectors, have been compared. Commercial UV source (medium pressure mercury short arc lamp) and UVA detectors were used as transfer standards in the comparison. Measurement results from participants were reported and their uncertainties associated with the comparison were analysed in this report. The method of weighted mean with cut-off was used to calculate the comparison reference values. The results from most participating labs lie within ±5% against the comparison reference values with a few exceptions. The degree of agreement of the comparison depends not only on the base scales of spectral responsivity and spectral irradiance of a laboratory, but also equally importantly on the method used for the measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. SUPPLEMENTARY COMPARISON: Final report on Supplementary Comparison APMP.M.H-S1

    NASA Astrophysics Data System (ADS)

    Kongkavitool, Rugkanawan; Hattori, Koichiro; Sanh, Vo; Yen, Lim Gin

    2007-01-01

    This report presents the results of supplementary comparison APMP.M.H-S1 among four national metrology institutes (NIMT, NMIJ/AIST, VMI and SPRING). The comparison was carried out during October 2004 to January 2005 in order to determine the capability of the primary Rockwell hardness standard, including standard conditions, of each participant, to confirm the accuracy of Rockwell hardness scale C measurement declared by the participant, which includes the effect of each participant's primary indenter and determine the degrees of equivalence of hardness scale measurement in the range 20 HRC to 60 HRC. Furthermore, the comparison was carried out a by common indenter, which was provided by the pilot institute, in order to determine the measurement capability of the participant's primary machine without the influence of the indenter, as a study of scientific purpose. The pilot institute was the National Institute of Metrology (Thailand), NIMT. There were two sets of artifacts for the comparison. Each set was composed of nine hardness blocks: 20 HRC, 25 HRC, 30 HRC, 35 HRC, 40 HRC, 45 HRC, 50 HRC, 55 HRC, 60 HRC. The verification of the participant's primary Rockwell hardness machine was carried out according to ISO6508-3 before making the measurement. The pilot institute made measurements at the beginning and the end of the comparison in order to monitor the stability of the artifacts. The degree of equivalence of each national primary hardness standard was expressed quantitatively by two terms, the deviation from KCRV and the uncertainty of this deviation at a 95% level of confidence. The En parameter was calculated to express the equivalence between the measurements of participants as well. The degree of equivalence between pairs of participating institutes was expressed by the difference of their deviations from the key comparison reference value and the uncertainty of this difference at the 95% level of confidence. Main text. To reach the main text of this paper

  20. Final report on key comparison APMP.M.P-K3: Absolute pressure measurements in gas from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Yoshida, H.; Arai, K.; Akimichi, H.; Hong, S. S.; Song, H. W.

    2011-01-01

    The results of a key comparison of ultra-high vacuum standards at two national metrology institutes (NMIJ/AIST and KRISS) are reported. This bilateral comparison was carried out from May 2010 to October 2010 within the framework of the Asia-Pacific Metrology Programme (APMP) to determine their degrees of equivalence at pressures in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. The pilot institute was NMIJ/AIST. Two spinning rotor gauges and two hot cathode ionization gauges were used as the transfer standards. NMIJ/AIST used two calibration systems: the dynamic expansion system (NMIJ-DES) and two-stage flow-dividing system (NMIJ-TFS). KRISS used the dynamic expansion system. The transfer standards were sufficiently stable to meet the requirements of the comparison compared with those of previous international comparisons owing to some improvements of the protocol and the transfer standards. The ultra-high vacuum standards of NMIJ/AIST and KRISS were found to be equivalent within their claimed uncertainties in the range from 3 × 10-6 Pa to 9 × 10-5 Pa. The NMIJ-DES results, which have smaller uncertainty than NMIJ-TFS, were transferred to the corresponding CCM key comparison, CCM.P-K3, in the range from 3 × 10-6 Pa to 9 × 10-5 Pa and it is shown that the NMIJ values were equivalent to the CCM key comparison reference value within the claimed uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the IST-LPSR, Portugal and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Cardoso, J.

    2018-01-01

    A comparison of the standards for air kerma of the Instituto Superior Técnico, Laboratório de Proteção e Segurança Radiológica (IST-LPSR), Portugal and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in December 2015. The comparison result, evaluated as a ratio of the IST-LPSR and the BIPM standards for air kerma, is 1.0026 with a combined standard uncertainty of 1.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 1.1 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Bilateral Comparison of 1 V and 10 V Standards between the SMD (Belgium) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Vlad, D.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Service Métrologie—Metrologische Dienst (SMD), Brussel, Belgium, was carried out from October to November 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to SMD and also back to BIPM. At SMD, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at SMD, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by SMD, at the level of 1.018 V and 10 V, at SMD, USMD, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 November 2014. USMD - UBIPM = 0.14 mV; uc = 0.07 mV, at 1 V USMD - UBIPM = 0.09 mV; uc = 0.49 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at SMD, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Bilateral Comparison of 1 V and 10 V Standards between the JV (Norway) and the BIPM, January to February 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Sengebush, F.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Justervesenet (JV), Kjeller, Norway, was carried out from January to February 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to JV and also back to BIPM. At JV, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at JV, withthe Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by JV, at the level of 1.018 V and 10 V, at JV, UJV, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 28 January 2015. UJV - UBIPM = 0.23 μV uc = 0.03 μV , at 1 V UJV - UBIPM = 0.63 μV uc = 0.28 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at JV, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral Comparison of 1 V and 10 V Standards between the NIMT (Thailand) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute of Metrology (Thailand), NIMT, was carried out from October to December 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPM6 (Z6), were transported by freight to NIMT and back to BIPM. At NIMT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIMT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by NIMT, at the level of 1.018 V and 10 V, at NIMT, UNIMT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 November 2014. UNIMT - UBIPM = 0.16 mV; uc = 0.14 mV, at 1 V UNIMT - UBIPM = - 0.03 mV; uc = 0.11 mV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIMT, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. KEY COMPARISON: Final report on CCQM-K44: Trace elements in sewage sludge

    NASA Astrophysics Data System (ADS)

    Aregbe, Y.; Taylor, P. D. P.

    2009-01-01

    CCQM-K44 was an activity of the Inorganic Analysis Working Group (IAWG) of CCQM and was coordinated by the Joint Research Centre-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) of the European Commission (EC). In CCQM-K44 the amount contents of Cd, Cr, Cu, Pb, Hg, Ni and Zn in sewage sludge were the measurands under investigation. Results were reported by six national metrology institutes (NMIs). During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and agreed on. The final report was submitted in June 2006. After the final report had been submitted to the CCQM in June 2006 the coordinating laboratory was informed that MIRS/IJS was not a designated institute and therefore could not represent the Slovenian NMI in CCQM-K44. This was contrary to what MIRS confirmed to the coordinating laboratory at the beginning of CCQM-K44. After several discussions between MIRS and the CCQM the coordinating laboratory was asked to amend the final report accordingly. In this revised version of the CCQM-K44 final report the results of MIRS/IJS were taken out of CCQM-K44 and included in the pilot study CCQM-P70, which was organised in parallel to CCQM-K44. Due to the limited number of participants compared to previous key comparisons the mixture model median (MM-median) of all reported results could not be applied as KCRV for all the measurands. During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and first agreed on. As a result the final report and degrees of equivalence were finalised and submitted to the CCQM. Subsequent discussions between the IAWG and the CCQM were held, resulting in a different approach as proposed by the coordinating laboratory. Particularly Maurice Cox from NPL recommended the weighted mean and its standard uncertainty (k = 1) as KCRV

  7. KEY COMPARISON: CCQM-K61: Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA

    NASA Astrophysics Data System (ADS)

    Woolford, Alison; Holden, Marcia; Salit, Marc; Burns, Malcolm; Ellison, Stephen L. R.

    2009-01-01

    Key comparison CCQM-K61 was performed to demonstrate and document the capability of interested national metrology institutes in the determination of the quantity of specific DNA target in an aqueous solution. The study provides support for the following measurement claim: "Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA". The comparison was an activity of the Bioanalysis Working Group (BAWG) of the Comité Consultatif pour la Quantité de Matière and was coordinated by NIST (Gaithersburg, USA) and LGC (Teddington, UK). The following laboratories (in alphabetical order) participated in this key comparison. DMSC (Thailand); IRMM (European Union); KRISS (Republic of Korea); LGC (UK); NIM (China); NIST (USA); NMIA (Australia); NMIJ (Japan); VNIIM (Russian Federation) Good agreement was observed between the reported results of all nine of the participants. Uncertainty estimates did not account fully for the dispersion of results even after allowance for possible inhomogeneity in calibration materials. Preliminary studies suggest that the effects of fluorescence threshold setting might contribute to the excess dispersion, and further study of this topic is suggested Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Report on the bilateral comparison between BIM (Bulgaria) and VSL (The Netherlands)

    NASA Astrophysics Data System (ADS)

    Dekker, Paul; Kunova, Angela; Dierikx, Erik

    2017-01-01

    A bilateral comparison has been organized between VSL, The Netherlands and BIM, Bulgaria in the field of spectral regular transmittance measurements. This comparison is registered as EURAMET project nr. 1073 and EURAMET.PR-K6.2 in the BIPM key comparison database. The aim of the comparison is to demonstrate the improvement of calibration measurement capabilities of BIM in this working field. If this comparison is successful, i.e. the results support the claimed improvement in uncertainties, the improved CMC's for BIM will be included in Appendix C of the CIPM mutual recognition arrangement (MRA). The results of this comparison are linked to key comparison CCPR K6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. International comparison of AC-DC current transfer standards

    NASA Astrophysics Data System (ADS)

    Heine, G.; Garcocz, M.; Waldmann, W.

    2017-01-01

    The measurements of the international comparison of ac-dc current transfer standards identified as EURAMET.EM-K12 started in June 2012 and were completed in December 2014. Twenty NMIs in the EURAMET region and one NMI in the AFRIMET region took part: BEV (Austria), CMI (Czech Republic), PTB (Germany), METAS (Switzerland), JV (Norway), UME (Turkey), GUM (Poland), IPQ (Portugal), CEM (Spain), INRIM (Italy), SP (Sweden), DANIAmet-MI-Trescal (Denmark), BIM (Bulgaria), MKEH (Hungary), SIQ (Slovenia), LNE (France), NSAI NML (Ireland), VSL (The Netherlands), NPL (United Kingdom), Metrosert (Estonia), NIS (Egypt). The comparison was proposed to link the National Metrology Institutes organised in EURAMET to the key comparison CCEM-K12. The ac-dc current transfer difference of each travelling standard had been measured at its nominal current 10 mA and 5 A at the following frequencies: 10 Hz, 55 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz. The test points were selected to link the results with the equivalent CCEM Key Comparison (CCEM-K12), through five NMIs participating in both EURAMET and CCEM key comparisons (PTB, JV, NPL, SP and BEV). The report shows the degree of equivalence in the EURAMET region and also the degree of equivalence with the corresponding CCEM reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Key comparison study on peptide purity—synthetic human C-peptide

    NASA Astrophysics Data System (ADS)

    Josephs, R. D.; Li, M.; Song, D.; Westwood, S.; Stoppacher, N.; Daireaux, A.; Choteau, T.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Flatschart, R.; Borges Oliveira, R.; Melanson, J. E.; Ohlendorf, R.; Henrion, A.; Kinumi, T.; Wong, L.; Liu, Q.; Oztug Senal, M.; Vatansever, B.; Ün, I.; Gören, A. C.; Akgöz, M.; Quaglia, M.; Warren, J.

    2017-01-01

    Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115, was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM). Eight Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of human C-peptide (hCP) present as the main component in the comparison sample for CCQM-K115. The comparison samples were prepared from synthetic human hCP purchased from a commercial supplier and used as provided without further treatment or purification. hCP was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of short (up to 5 kDa), non-cross-linked synthetic peptides/proteins. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used a peptide impurity corrected amino acid analysis (PICAA) approach as the amount of material that has been provided to each participant (25 mg) is insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, both the BIPM and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the hCP mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the hCP purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the hCP mass fraction. In particular it allows participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification

  11. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    NASA Astrophysics Data System (ADS)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Final report of the key comparison CCQM-K106: Pb, As and Hg measurements in cosmetic (cream)

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Wang, Qian; Yamani, Randa Nasr Ahmed; Shehata, Adel B.; Jacimovic, Radojko; Pavlin, Majda; Horvat, Milena; Tsoi, Y. P.; Tsang, C. K.; Shin, Richard; Chailap, Benjamat; Yafa, Charun; Caciano de Sena, Rodrigo; de Almeida, Marcelo; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Heun Kim, Sook; Konopelko, Leonid; Ari, Betül; Tokman, Nilgün; Rienitz, Olaf; Jaehrling, Reinhard; Pape, Carola

    2015-01-01

    Cosmetics are used in practically all walks of life as a means of improving skin and beautifying complexion. In recent years, more and more attention has been paid to the cosmetic safety. In response to the cosmetic safety issue, the accurate measurement of the heavy metals in cosmetics is, therefore, particularly important. NMIs from different countries should establish their chemical metrology traceability system in this area, which includes both measurement methods research and certain CRMs development. It should be noted that because the matrix of many cosmetics is complex and the contents of the heavy metals are relatively low, it still is a challenging task to measure the analytes with high accuracy and precision. CCQM-K106 followed up CCQM pilot study 'CCQM-P128: Pb, As measurements in cosmetic (cream)' coordinated by the National Institute of Metrology, China (NIM) in 2009. The cream was selected as the testing material, which is widely used as a daily skin care worldwide. This is the first CCQM key comparison regarding the measurement of toxic metal elements with the cosmetic matrix, which includes pure water, liquid paraffin, silicone oil, synthetic squalane, hyaluronic acid, glycerin, propylene glycol, allantoin, preservative and so on. The aim of the CCQM-K106 is to demonstrate the capability of participating NMIs and designated institutes in measuring the contents of poisonous elements, including lead, arsenic and mercury in a cosmetic sample (cream), and support CMC claims relating to inorganic elements in cosmetic materials and similar chemical industry products. The cream matrix sample was prepared under the guidance of professional technicians. The formula of the cream was carefully chosen to match with a real cosmetic. The homogeneity and stability level of Pb, As and Hg in the cream sample were fit for the objective of the comparison. Each participant received two numbered bottles containing about 5g samples in each bottle. The instruction

  14. KEY COMPARISON: CCQM-K28: Tributyltin in sediment

    NASA Astrophysics Data System (ADS)

    Wolff Briche, Céline S. J.; Wahlen, Raimund; Sturgeon, Ralph E.

    2006-01-01

    Key comparison CCQM K-28 was undertaken to assess the measurement capabilities for quantitation of (C4H9)3Sn+ (TBT) in a prepared marine sediment by National Metrology Institutes (NMIs), which are members of the Comité Consultatif pour la Quantité de Matière (CCQM). It follows a previous pilot study, CCQM-P18. [1, 2] This exercise was sanctioned by the 8th CCQM meeting, 18-19 April 2002, as an activity of the Inorganic Analysis Working Group and was jointly coordinated by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and LGC, UK. Eight NMIs initially indicated their interest, with seven ultimately submitting their results. All NMIs relied on isotope dilution mass spectrometry using a species-specific 117Sn-enriched TBT standard, which was supplied by LGC. No analytical methodology was prescribed for this study. As a result, a variety of extraction approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with ethylation and direct sampling. Detection techniques included ICP-MS (coupled to GC or HPLC for the separation of Sn species) and GC-MS. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  15. KEY COMPARISON Update of the BIPM.RI(II)-K1.Tc-99m comparison of activity measurements for the radionuclide 99mTc to include new results for the LNE-LNHB and the NPL

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Moune, M.; Johansson, L.; Keightley, J.

    2010-01-01

    In 2007 and 2008 respectively, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of 99mTc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNHB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. SUPPLEMENTARY COMPARISON: APMP.EM-S6: Bilateral supplementary comparison of resistance

    NASA Astrophysics Data System (ADS)

    Charoensook, Ajchara; Jassadajin, Chaiwat; Chen, Henry; Ricketts, Brian

    2004-01-01

    A bilateral supplementary comparison of resistance, APMP.EM-S6, was conducted between the National Institute of Metrology Thailand (NIMT) and the CSIRO National Measurement Laboratory of Australia (NML). The comparison covered seven values of resistance, 0.1 Ω, 1 Ω, 100 Ω, 10 kΩ, 100 kΩ, 1 MΩ and 100 MΩ. The 0.1 Ω resistor was a YEW type 2792, the 100 MΩ resistor was an IET type SRC and the other five resistors were Fluke type 742A. The resistors were supplied by NIMT, and NML was the pilot laboratory for the comparison. The measurements for the comparison were made between December 2003 and April 2004. The resistors were measured on three separate occasions by NIMT and between each of these occasions the resistors were sent to NML for measurement. The resistors of nominal values 0.1 Ω, 1 Ω, 100 Ω and 10 kΩ were measured as four-terminal resistors while the 100 kΩ, 1 MΩ and 100 MΩ resistors were measured as two-terminal resistors. The quantity En (the absolute value of the difference between the values obtained at the two laboratories divided by the root sum square of the expanded uncertainties of the two values) was calculated for each resistance value used in the comparison. In all cases En was less than 0.5. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the Mutual Recognition Arrangement (MRA).

  17. Characteristics of precision 1 Ω standard resistors influencing transport behaviour and the uncertainty of key comparisons

    NASA Astrophysics Data System (ADS)

    Jones, G. R.; Pritchard, B. J.; Elmquist, R. E.

    2009-10-01

    National measurement institutes (NMIs) participate in international key comparisons organized by the Bureau International des Poids et Mesures (BIPM), the Regional Metrology Organizations (RMOs) or the Consultative Committees of the Comité International des Poids et Mesures (CIPM) in order to provide evidence of equivalent reference standards and measurement capabilities. The US National Institute of Standards and Technology (NIST) and the National Measurement Institute of Australia (NMIA) have recently examined power loading and several other influences on the value of precision transportable 1 Ω resistors that can increase the uncertainty of key comparisons. We have studied the effects of temperature, barometric pressure, humidity, power loading and heat dissipation in oil on transportable wire-wound 1 Ω resistance standards that are based on different alloys and construction principles. This work focuses on standards manufactured from 1970 through 2000 by the NMIA made of Evanohm alloy and on Thomas-type resistors designed in the 1930s and made of Manganin alloy. We show that the relative standard uncertainty related to transport can be less than 0.01 μΩ Ω-1 when using certain resistors of these two types that are characterized and selected for stability. We describe the characterization process, and relate the environmental influences to the physical design, as well as to the mechanical properties and condition of the standards.

  18. COOMET.QM-K93 (COOMET 615/RU/13): key comparison in the field of measuring of the ethanol amount fraction in nitrogen (120 μmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Efremova, O. V.; Fatina, O. V.; Orshanskaia, A. A.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.

    2016-01-01

    The relevance of the COOMET.QM-K93 comparison is founded on paying particular attention to reliability of measurements which are performed during the medical examination of drivers of vehicles in order to assess the degree of alcoholic intoxication. Standard gas mixtures of ethanol in nitrogen in cylinders under pressure play a key role in providing metrological assurance of breath-alcohol analyzers. Participating laboratories: VNIIM and Ukrmetrteststandart. This comparison was carried out in 2014-2015. This supplementary comparison supports CMC claims for: ethanol in the range 50-500 μmol/mol in a matrix of either nitrogen or synthetic air. Results: The results are consistent with the reference values. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report on bilateral comparison SIM.EM-S9.b: Comparison of resistance standards at 1 Ω and 10 kΩ between INIMET (Cuba) and INTI (Argentina), March to October 2012

    NASA Astrophysics Data System (ADS)

    Tonina, A.; Currás, M.; Navarro, M.

    2014-01-01

    The CIPM MRA states that its technical basis is a set of results obtained in a course of time through key comparisons carried out by the Consultative Committees of the CIPM, the BIPM and the Regional Metrology Organizations (RMOs). As part of this process, INTI (Argentina) has participated in several key and supplementary comparisons. By means of procedures for linking key comparison data, a bilateral comparison would help to provide assurance of equality in measurements between the participating laboratories. With this end, the comparison SIM.EM-S9.b of 1 ohm and 10 kiloohm standard resistors of INIMET (Cuba) and INTI was carried out from March to October 2012. The obtained results were very good. They show that the resistance standards maintained by INTI and INIMET were equivalent, within their combined uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Zivkovic, V.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Directorate of Measures and Precious Metals (DMDM), Beograd, Serbia, was carried out from January to March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMA (ZA), were transported by freight to DMDM. At DMDM, the reference standard for DC voltage is a Josephson Voltage Standard. The output electromotive force of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DMDM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DMDM, at the level of 1.018 V and 10 V, at DMDM, UDMDM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 13 February 2014. UDMDM - UBIPM = 0.094 µV uc = 0.072 µV, at 1 V UDMDM - UBIPM = 0.39 µV uc = 0.12 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DMDM, based on KJ-90, and the uncertainty related to the comparison. The results at the 10 V level are not covered by the uncertainties with a coverage factor of 2. After the distribution of the Draft A, the DMDM discovered that the pressure gauge was defective. Some considerations on the correction to apply on the comparison result and the corresponding uncertainties are presented in the report. Nevertheless, the above results fully cover the CMCs of DMDM which are significantly larger. No corrections for temperature and pressure are applied in calibrations for

  1. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    NASA Astrophysics Data System (ADS)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Bilateral comparison of 1 V and 10 V standards between the DEFNAT (Tunisia) and the BIPM February to March 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Ben Salah, B.; Mallat, A.; Abene, L.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Electrique, DEFNAT (Tunisia), was carried out from February to March 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMC (ZC) and BIPM6 (Z6), were transported by freight to DEFNAT and back to BIPM. In order to keep the Zeners powered during their transportation phase, a BIPM in-house voltage stabiliser was connected in parallel to the internal battery. The voltage stabiliser consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for 10 consecutive days. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DEFNAT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT, UDEFNAT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 26th of February 2016. UDEFNAT - UBIPM = + 0.07 μV uc = 0.04 μV, at 1.018 V UDEFNAT - UBIPM = + 0.38 μV uc = 0.10 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  3. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -25 °C TO +20 °C.

    PubMed

    Meyer, C W; Hill, K D

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC.

  4. Final report on the key comparison, CCM.P-K15 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Arai, Kenta; Bergoglio, Mercede; Fedchak, James A.; Jousten, Karl; Hong, Seung Soo; Torres Guzman, Jorge

    2017-01-01

    The comparison CCM.P-K15 is a key comparison in pressure involving six laboratories in three regional metrological organizations (RMO). The measurand of the comparison is the accommodation coefficient of two spinning rotating gauge characterized in nitrogen from 0.1 mPa up to 1.0 Pa. The two transfer standards were circulated from November 2009 until March 2011. The circulation consisted of three loops, one for each RMO, and a new calibration by the pilot be-tween each loop. The stability of one of the transfer standards was poor and was worse than expected based on the previous history of the transfer standard while the other transfer standard demonstrated good stability while circulated in Europe and America and a fair stability while circulated in Asia. All the participants demonstrated equivalence to the definition of pressure in their respective primary standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Conducting indirect-treatment-comparison and network-meta-analysis studies: report of the ISPOR Task Force on Indirect Treatment Comparisons Good Research Practices: part 2.

    PubMed

    Hoaglin, David C; Hawkins, Neil; Jansen, Jeroen P; Scott, David A; Itzler, Robbin; Cappelleri, Joseph C; Boersma, Cornelis; Thompson, David; Larholt, Kay M; Diaz, Mireya; Barrett, Annabel

    2011-06-01

    Evidence-based health care decision making requires comparison of all relevant competing interventions. In the absence of randomized controlled trials involving a direct comparison of all treatments of interest, indirect treatment comparisons and network meta-analysis provide useful evidence for judiciously selecting the best treatment(s). Mixed treatment comparisons, a special case of network meta-analysis, combine direct evidence and indirect evidence for particular pairwise comparisons, thereby synthesizing a greater share of the available evidence than traditional meta-analysis. This report from the International Society for Pharmacoeconomics and Outcomes Research Indirect Treatment Comparisons Good Research Practices Task Force provides guidance on technical aspects of conducting network meta-analyses (our use of this term includes most methods that involve meta-analysis in the context of a network of evidence). We start with a discussion of strategies for developing networks of evidence. Next we briefly review assumptions of network meta-analysis. Then we focus on the statistical analysis of the data: objectives, models (fixed-effects and random-effects), frequentist versus Bayesian approaches, and model validation. A checklist highlights key components of network meta-analysis, and substantial examples illustrate indirect treatment comparisons (both frequentist and Bayesian approaches) and network meta-analysis. A further section discusses eight key areas for future research. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  6. APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Joung, W.; Gam, K. S.; Achmadi, A.; Trisna, B. A.

    2016-01-01

    The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Bilateral comparison of 1 V and 10 V standards between the NMISA (South Africa) and the BIPM April to June 2017 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Matlejoane, A. M.; Magagula, L.; Stock, M.

    2018-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the National Metrology Institute of South Africa, NMISA (South Africa), was carried out from April to June 2017. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPMB (ZB), were transported by freight to NMISA and back to BIPM. In order to keep the Zeners powered during their transportation phase, a voltage stabilizer developed by BIPM was connected in parallel to the internal battery. It consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for ten consecutive days. At NMISA, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NMISA, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NMISA, at the level of 1.018 V and 10 V, at NMISA, UNMISA, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference dates of the 19th and 18th of May 2017, respectively. UNMISA - UBIPM = + 0.07 μV uc = 0.02 μV, at 1.018 V UNMISA - UBIPM = + 0.001 μV uc = 0.34 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NMISA, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  8. SUPPLEMENTARY COMPARISON: COOMET.RI(II)-S1.Rn-222 (169/UA/98): Rn-222 volume activity comparison

    NASA Astrophysics Data System (ADS)

    Skliarov, V.; Röttger, A.; Honig, A.; Korostin, S.; Kuznetsov, S.; Lapenas, A.; Milevsky, V.; Ivaniukovich, A.; Kharitonov, I.; Sepman, S.

    2009-01-01

    According to a first program, a supplementary comparison of Rn-222 volume activity was drawn up as a bilateral supplementary comparison between NSC 'Institute of Metrology', Ukraine, and VNIIFTRI, Russia. It took place in March 2005. In April 2005, at the 5th meeting of COOMET held in Braunschweig (Germany), representatives of these institutes exchanged data which showed the comparability of the national standards of Ukraine and Russia for the check points. During the discussion of the procedure some other institutes decided to join the comparison program, which was extended to BelGIM (Belarus), PTB (Germany), VNIIM (Russia) and RMTC (Latvia). The national standards of volume activity of radon-222 were thus calibrated using one standard radon radiometer as the transfer standard. Results are shown in the Final Report of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by COOMET, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. KEY COMPARISON: Final report of APMP.T-K6 (original name APMP-IC-1-97): Comparison of humidity measurements using a dew point meter as a transfer standard

    NASA Astrophysics Data System (ADS)

    Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.

    2007-01-01

    This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Final report on COOMET.AUV.A-S1: Technical report on supplementary comparison 'Comparison of national standards of the sound pressure unit in air through calibration of working reference microphones'

    NASA Astrophysics Data System (ADS)

    Pozdeeva, Valentina; Chalyy, Vladimir

    2014-01-01

    The supplementary comparison COOMET.AUV.A-S1 for secondary calibration methods using WS1 and WS2 measurement microphones was carried out from 2009 to 2010. The results were submitted to and approved by CCAUV in April 2014. Four National Metrology Institutes took part in this comparison and are as follows: BelGIM (Belarus), VNIIFTRI (Russia), SMU (Slovakia) and DP NDI 'Sistema' (Ukraine). Three of the above NMIs (VNIIFTRI, SMU and DP NDI 'Sistema') had earlier participated in COOMET key comparisons and one NMI (VNIIFTRI) had also participated in CCAUV key comparisons. The Comparison Reference Values were calculated as the weighted mean values from results obtained by three institutes. The comparison results show agreement for all participants in the frequency range from 20 Hz to 12.5 kHz for WS1 microphones, and in the frequency range from 20 Hz to 16 kHz for WS2 microphones. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report of key comparison AFRIMETS.AUV.A-K5: primary pressure calibration of LS1P microphones according to IEC 61094-2, over the frequency range 2 Hz to 10 kHz.

    NASA Astrophysics Data System (ADS)

    Nel, R.; Avison, J.; Harris, P.; Blabla, M.; Hämäläinen, J.

    2017-01-01

    The degrees of equivalence of the AFRIMETS.AUV.A-K5 regional key comparison are reported here as the final report. The scope of the comparison covered the complex pressure sensitivities of two LS1P microphones over the frequency range 2 Hz to 10 kHz in accordance with IEC 61094-2: 2009. Four national metrology institutes from two different regional metrology organisations participated in the comparison. Two LS1P microphones were circulated simultaneously to all the participants in a circular configuration. One of the microphones sensitivity shifted and all results associated with this microphone were subsequently excluded from further analysis and linking. The AFRIMETS.AUV.A-K5 comparison results were linked to the CCAUV.A-K5 comparison results via dual participation in the CCAUV.A-K5 and AFRIMETS.AUV.A-K5 comparisons. The degrees of equivalence, linked to the CCAUV.A-K5 comparison, were calculated for all participants of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −25 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Hill, K.D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952

  13. SUPPLEMENTARY COMPARISON: EUROMET.L-S10 Comparison of squareness measurements

    NASA Astrophysics Data System (ADS)

    Mokros, Jiri

    2005-01-01

    from the weighted mean of data from participating laboratories, while some of them were excluded on the basis of statistical evaluation. Graphical interpretations of all deviations are contained in the Final Report. In order to compare the individual deviations mutually (25 profiles for the granite square and 44 profiles for the cylinder), graphical illustrations of 'standard deviations' and both extreme values (max. and min.) of deviations were created. This regional supplementary comparison has provided independent information about the metrological properties of the measuring equipment and method used by the participating NMIs. The Final Report does not contain the En values. Participants could not estimate some contributions in the uncertainty budget on the basis of previous comparisons, since no comparison of this kind had ever been organized. Therefore the En value cannot reflect the actual state of the given NMI. Instead of En, an analysis has been performed by means of the Grubbs test according to ISO 5725-2. This comparison provided information about the state of provision of metrological services in the field of big squares measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EUROMET, according to the provisions of the Mutual Recognition Arrangement (MRA).

  14. KEY COMPARISON: CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

    NASA Astrophysics Data System (ADS)

    Seah, M. P.

    2008-01-01

    CCQM-K32 and P84 were conducted following the pilot study P-38 to demonstrate and document the capability of interested National Metrology Institutes to measure the amount of silicon oxide on silicon wafers expressed as a thickness of SiO2 for nominal thicknesses in the range 1.5 nm to 8 nm. 'Amount of substance' may be expressed in many ways and here the measurand is the thickness of the silicon oxide layer on each of a total of 9 samples of nominal thicknesses in the range 1.5 to 8 nm on (100) and (111) Si substrates, expressed as the thickness of SiO2. This report presents the results from K32 and P84. It includes the data received for the measured values and their associated uncertainties, at 95% confidence, for the 9 samples prior to the deadline for receipt of data. The materials are grown by thermal oxidation in very clean furnaces designed for high quality gate oxides on Si wafers in European and US facilities at the same time as those for the pilot study, P-38. Separate samples were provided to each institute in special containers limiting the carbonaceous contamination to below about 0.3 nm. The 9 samples included 5 samples of ultra-thin SiO2 on (100) orientated wafers of Si and 4 samples of ultra-thin SiO2 on (111) orientated wafers of Si. The measurements from the 11 participating laboratories were conducted using ellipsometry, neutron reflectivity (NR), x-ray photoelectron spectroscopy (XPS) or x-ray reflectivity measurements (XRR), guided by the protocol developed in the pilot study P-38 and reproduced in the Appendix. The measurements are given in tables 2 and 3. A very small correction is then made for the different samples that each laboratory received as in table 4. Where appropriate, method offset values deduced from the pilot study P-38 are given in table 5 leading to comparative data in tables 6 and 7. Values for the key comparison reference values (KCRVs) and their associated uncertainties are made from the weighted means and the expanded

  15. KEY COMPARISON: CCEM.RF-K18.CL (GT-RF/00-1): Noise in 50 Ω coaxial line at frequencies up to 1 GHz

    NASA Astrophysics Data System (ADS)

    Eiø, Christopher; Adamson, David; Randa, James; Allal, Djamel; Uzdin, Rinadij

    2006-01-01

    A measurement comparison of noise temperature has been carried out between four national metrology laboratories in coaxial line at 30 MHz, 60 MHz and 1 GHz. The identification of this intercomparison is CCEM.RF-K18.CL. Two noise sources have been measured. The following four national laboratories participated in this intercomparison: NPL (United Kingdom), NIST (United States of America), BNM-LNE (France) and VNIIFTRI (Russia). The National Physical Laboratory (UK) acted as the pilot laboratory for the comparison. It can be seen that there is generally good agreement between the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    PubMed

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  17. Final report on key comparison APMP.M.P-K13 in hydraulic gauge pressure from 50 MPa to 500 MPa

    NASA Astrophysics Data System (ADS)

    Kajikawa, Hiroaki; Kobata, Tokihiko; Yadav, Sanjay; Jian, Wu; Changpan, Tawat; Owen, Neville; Yanhua, Li; Hung, Chen-Chuan; Ginanjar, Gigin; Choi, In-Mook

    2015-01-01

    This report describes the results of a key comparison of hydraulic high-pressure standards at nine National Metrology Institutes (NMIs: NMIJ/AIST, NPLI, NMC/A*STAR, NIMT, NMIA, NIM, CMS/ITRI, KIM-LIPI, and KRISS) within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence in the pressure range from 50 MPa to 500 MPa in gauge mode. The pilot institute was the National Metrology Institute of Japan (NMIJ/AIST). All participating institutes used hydraulic pressure balances as their pressure standards. A set of pressure balance with a free-deformational piston-cylinder assembly was used as the transfer standard. Three piston-cylinder assemblies, only one at a time, were used to complete the measurements in the period from November 2010 to January 2013. Ten participants completed their measurements and reported the pressure-dependent effective areas of the transfer standard at specified pressures with the associated uncertainties. Since one of the participants withdrew its results, the measurement results of the nine participants were finally compared. The results were linked to the CCM.P-K13 reference values through the results of two linking laboratories, NMIJ/AIST and NPLI. The degrees of equivalence were evaluated by the relative deviations of the participants' results from the CCM.P-K13 key comparison reference values, and their associated combined expanded (k=2) uncertainties. The results of all the nine participating NMIs agree with the CCM.P-K13 reference values within their expanded (k=2) uncertainties in the entire pressure range from 50 MPa to 500 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. The psychological costs of comparisons: Parents' social comparison moderates the links between family management of epilepsy and children's outcomes.

    PubMed

    Mendes, Teresa P; Crespo, Carla A; Austin, Joan K

    2017-10-01

    Parents play a key role in how children deal with epilepsy. When diagnosed with health conditions, people seek comparison information from fellow patients and families, and this information has consequences for how they evaluate their situation. This study examined the moderating role of parents' social comparison orientation in the associations between family management (parental perceptions of family life difficulties and child's daily life) and adaptation outcomes of children with epilepsy (HRQoL and perceived stigma). Participants included 201 dyads of children with epilepsy and either their mother or father. The results showed that when parents perceived higher difficulties managing their child's epilepsy and/or reported that their child was more affected by this condition, children reported higher perceived stigma and worse HRQoL only when parents had a higher social comparison orientation. Our results are innovative in showing that when parents have a higher social comparison orientation, their children may be at increased risk of poorer outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. CCM.FF-K3.2011: Final report for the CIPM key comparison of air speed, 0.5 m/s to 40 m/s

    NASA Astrophysics Data System (ADS)

    Müller, Harald; Caré, Isabelle; Lucas, Peter; Pachinger, Dietmar; Kurihara, Noboru; Lishui, Cui; Su, Chun-Min; Shinder, Iosif; Spazzini, Pier Giorgio

    2017-01-01

    The CCM.FF-K3.2011 comparison was organized for the purpose of determination of the degree of equivalence of the national standards for air speed over the range 0.5 m/s to 40 m/s. An ultrasonic anemometer and a Laser Doppler anemometer were used as transfer standards. Nine laboratories from three RMOs participated between July 2013 and July 2015—EURAMET: PTB, Germany; LNE-CETIAT, France; INRIM, Italy; VSL, The Netherlands; E+E, Austria; SIM: NIST, USA; APMP: NMIJ/AIST, Japan; NIM, China; CMS/ITRI, Chinese Taipei. The measurements were provided at ambient conditions. All results of independent participants were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each air speed separately following `procedure A' presented by M G Cox. The degree of equivalence with the KCRV was calculated for each air speed and laboratory. Almost all reported results were consistent with the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  1. Comparison as a Universal Learning Action

    ERIC Educational Resources Information Center

    Merkulova, T. V.

    2016-01-01

    This article explores "comparison" as a universal metasubject learning action, a key curricular element envisaged by the Russian Federal State Educational Standards. Representing the modern learner's fundamental pragmatic skill embedding such core capacities as information processing, critical thinking, robust decision-making, and…

  2. Final report on EURAMET.M.P-K4.2010: Key and supplementary comparison of national pressure standards in the range 1 Pa to 15 kPa of absolute and gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajíček, Zdeněk; Bergoglio, Mercede; Jousten, Karl; Otal, Pierre; Sabuga, Wladimir; Saxholm, Sari; Pražák, Dominik; Vičar, Martin

    2014-01-01

    This report describes a EURAMET comparison of five European National Metrology Institutes in low gauge and absolute pressure in gas (nitrogen), denoted as EURAMET.M.P-K4.2010. Its main intention is to state equivalence of the pressure standards, in particular those based on the technology of force-balanced piston gauges such as e.g. FRS by Furness Controls, UK and FPG8601 by DHI-Fluke, USA. It covers the range from 1 Pa to 15 kPa, both gauge and absolute. The comparison in absolute mode serves as a EURAMET Key Comparison which can be linked to CCM.P-K4 and CCM.P-K2 via PTB. The comparison in gauge mode is a supplementary comparison. The comparison was carried out from September 2008 till October 2012. The participating laboratories were the following: CMI, INRIM, LNE, MIKES, PTB-Berlin (absolute pressure 1 kPa and below) and PTB-Braunschweig (absolute pressure 1 kPa and above and gauge pressure). CMI was the pilot laboratory and provided a transfer standard for the comparison. This transfer standard was also the laboratory standard of CMI at the same time, which resulted in a unique and logistically difficult star comparison. Both in gauge and absolute pressures all the participating institutes successfully proved their equivalence with respect to the reference value and all also proved mutual bilateral equivalences in all the points. All the participating laboratories are also equivalent with the reference values of CCM.P-K4 and CCM.P-K2 in the relevant points. The comparison also proved the ability of FPG8601 to serve as a transfer standard. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report of the supplementary comparison EURAMET.EM-S31 comparison of capacitance and capacitance ratio

    NASA Astrophysics Data System (ADS)

    Schurr, J.; Fletcher, N.; Gournay, P.; Thévenot, O.; Overney, F.; Johnson, L.; Xie, R.; Dierikx, E.

    2017-01-01

    Within the framework of the supplementary comparison EURAMET.EM-S31, 'Comparison of capacitance and capacitance ratio', five participants (the BIPM, METAS, LNE, PTB, and VSL) inter-compared their capacitance realisations traced to the quantum Hall resistance measured at either ac or dc. The measurands were the capacitance values of three 10 pF standards and one 100 pF standard, and optionally their voltage and frequency dependences. Because the results were not fully satisfying, the circulation was repeated, augmented by a link to the NMIA calculable capacitor. Also two ac-dc resistors were circulated and their frequency dependences were measured in terms of the ac-dc resistance standards involved in the particular capacitance realisations, to allow inter-comparison of these resistance standards. At the end and in any case, a good agreement is achieved within the expanded uncertainties at coverage factor k = 2. Furthermore, the comparison led to new insight regarding the stability and travelling behaviour of the capacitance standards and, by virtue of the link to the NMIA calculable capacitor, to a determination of the von Klitzing constant in agreement with the 2014 CODATA value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Comparisons of absolute gravimeters (COOMET.M.G-S1)

    NASA Astrophysics Data System (ADS)

    Vinnichenko, Mr Alexander; Germak, Alessandro, Dr

    2017-01-01

    This report describes the results of the RMO supplementary comparison COOMET.M.G-S1 (also known as bilateral comparison COOMET 634/UA/14). The comparison measurements between the two participants NSC 'IM' (pilot laboratory) and INRIM were started in December 2015 and finished in January 2016. Participants of comparisons were conducted at their national standards the measurements of the free fall acceleration in gravimetric point laboratory of absolute gravimetry of INRIM named INRiM.2. Absolute measurements of gravimetric acceleration were conducted by ballistic gravimeters. The agreement between the two participants is good. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. 16 CFR 233.2 - Retail price comparisons; comparable value comparisons.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...

  6. 16 CFR 233.2 - Retail price comparisons; comparable value comparisons.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...

  7. 16 CFR 233.2 - Retail price comparisons; comparable value comparisons.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...

  8. 16 CFR 233.2 - Retail price comparisons; comparable value comparisons.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...

  9. Final report on COOMET.QM-K76 (COOMET project no 484/RU/09): Key comparison of primary standard gas mixtures: SO2 in nitrogen (100 µmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Shor, N. B.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Kozia, V. G.; Shpilnyi, S. A.; Petryshyn, P. V.; Iakubov, S. E.; Kluchits, A. S.; Ananyin, V. N.; Mironchik, A. M.; Mokhnach, M. V.; Valkova, M.; Stovcik, V.

    2014-01-01

    Sulfur dioxide is one of the main contaminants present in the atmosphere due to burning of coal, oil and natural gas, smelting of base metals and production of sulfuric acid. Sulfur dioxide has been the subject of three previous CCQM key comparisons: CCQM-K1.d in 1997, CCQM-K26.b in 2005 and CCQM-K76 in 2010. VNIIM proposed a new COOMET project (No 484/RU/09) in this field, which was registered in the KCDB as key comparison COOMET.QM-K76. It was found that all results were consistent with the reference (gravimetric) values, with observed differences not exceeding ±0.60% and not exceeding either the appropriate assigned expanded uncertainties. VNIIM is the linking laboratory to CCQM-K76. SMU has improved the results obtained in CCQM-K76. The mixtures prepared for this exercise were found to be stable during about one year within the uncertainty of the measurements. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Supplement to CCM.D-K4 'Hydrometer' report: linkage of EURAMET.M.D-K4 comparison, SIM.M.D-K4 comparison and the supplementary SIM.M.D-S2 to CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.

    2017-01-01

    Evaluation of different types of comparisons to a common set of reference values of a CIPM key comparison is essential to satisfy the concept of the CIPM Mutual Recognition Arrangement (CIPM MRA), where the DoEs of any participant who took part in comparisons should be within the Calibration and Measurement Capability (CMC) section of the CIPM MRA Key Comparison Data Base. The subject of this supplementary report is therefore to present the equivalence of each National Metrological Institute (NMI) participant in the CCM.D-K4 'Hydrometer' key comparison, which was performed in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20 °C, and the linkage of the European and Inter-American NMI results performed in the RMO.M.D-K4 comparisons as well as those of the supplementary SIM.M.D-S2 to the common set of KCRVs of the CCM.D-K4 'Hydrometer'. The linking procedure has been obtained by numerical simulation, based on the Monte Carlo method, in which the differences in the results of the different comparison between the intended laboratory and one or more linking laboratory/ies, which took part in both comparisons, are correlated with a continuous function describing the DoEs of the linking laboratory/ies with respect to the common set of KCRVs of the CCM.D-K4. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Metrics for comparison of crystallographic maps

    DOE PAGES

    Urzhumtsev, Alexandre; Afonine, Pavel V.; Lunin, Vladimir Y.; ...

    2014-10-01

    Numerical comparison of crystallographic contour maps is used extensively in structure solution and model refinement, analysis and validation. However, traditional metrics such as the map correlation coefficient (map CC, real-space CC or RSCC) sometimes contradict the results of visual assessment of the corresponding maps. This article explains such apparent contradictions and suggests new metrics and tools to compare crystallographic contour maps. The key to the new methods is rank scaling of the Fourier syntheses. The new metrics are complementary to the usual map CC and can be more helpful in map comparison, in particular when only some of their aspects,more » such as regions of high density, are of interest.« less

  13. Infrared spectral normal emittance/emissivity comparison

    NASA Astrophysics Data System (ADS)

    Hanssen, L.; Wilthan, B.; Filtz, J.-R.; Hameury, J.; Girard, F.; Battuello, M.; Ishii, J.; Hollandt, J.; Monte, C.

    2016-01-01

    The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized Inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Reinforcer control by comparison-stimulus color and location in a delayed matching-to-sample task.

    PubMed

    Alsop, Brent; Jones, B Max

    2008-05-01

    Six pigeons were trained in a delayed matching-to-sample task involving bright- and dim-yellow samples on a central key, a five-peck response requirement to either sample, a constant 1.5-s delay, and the presentation of comparison stimuli composed of red on the left key and green on the right key or vice versa. Green-key responses were occasionally reinforced following the dimmer-yellow sample, and red-key responses were occasionally reinforced following the brighter-yellow sample. Reinforcer delivery was controlled such that the distribution of reinforcers across both comparison-stimulus color and comparison-stimulus location could be varied systematically and independently across conditions. Matching accuracy was high throughout. The ratio of left to right side-key responses increased as the ratio of left to right reinforcers increased, the ratio of red to green responses increased as the ratio of red to green reinforcers increased, and there was no interaction between these variables. However, side-key biases were more sensitive to the distribution of reinforcers across key location than were comparison-color biases to the distribution of reinforcers across key color. An extension of Davison and Tustin's (1978) model of DMTS performance fit the data well, but the results were also consistent with an alternative theory of conditional discrimination performance (Jones, 2003) that calls for a conceptually distinct quantitative model.

  15. Supplementary comparison EURAMET.L-S24 on involute gear standards

    NASA Astrophysics Data System (ADS)

    Kniel, K.; Chanthawong, N.; Eastman, N.; Frazer, R.; Kupko, V.; Osawa, S.; Xue, Z.

    2014-01-01

    At its meeting in 2007, the EURAMET TC-Length decided to run an intercomparison of involute gear standards as a regional comparison with non-European involvement. The Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany (PTB) was identified as the pilot laboratory, responsible for planning, organizing and analyzing the comparison. In all, seven participants from China, Germany, Japan, Thailand, Ukraine, United Kingdom and USA were asked to measure three different gear standards specialized for profile, helix and pitch measurements. The measurements started mid 2008 and were finished at the end of 2010. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The comparison was registered as the supplementary comparison EURAMET.L-S24. The final report has been peer-reviewed and approved for publication by the CCL WG-MRA, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the VSL, Netherlands and the BIPM in accelerator photon beams

    NASA Astrophysics Data System (ADS)

    Picard, S.; Burns, D. T.; Roger, P.; de Prez, L. A.; Jansen, B. J.; Pooter, J. A.

    2017-01-01

    A comparison of the dosimetry for accelerator photon beams was carried out between the Dutch Metrology Institute (VSL) and the Bureau International des Poids et Mesures (BIPM) from 23 September to 20 October 2014. The comparison was based on the determination of absorbed dose to water for three radiation qualities of the medical accelerator facilities of the National Physical Laboratory (United Kingdom). After establishing Draft B, the VSL discovered an error in the calculation of the correction factor for excess-heat linked to the VSL glass vessel used in the measurements at the NPL. The comparison results for the revised standard, reported as ratios of the VSL and the BIPM evaluations (and with the combined standard uncertainties given in parentheses), are 0.9959 (54) at 6 MV, 0.9958 (64) at 10 MV and 0.9991 (75) at 25 MV. This result is part of the on-going BIPM.RI(I)-K6 series of comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Prospective Relations between Social Comparison Orientation and Weight Loss Outcomes.

    PubMed

    Arigo, Danielle; Butryn, Meghan L

    2018-06-26

    Maintenance of weight loss after behavioral intervention tends to be poor, and there is need for an improved understanding of factors that are associated with successful maintenance. Social comparison is known to be a powerful influence on treatment outcomes for group-based behavioral weight loss programs, but little is known about the role of individual differences in social comparison orientation (i.e., tendency to value comparison information) in this context. The goal of this study was to examine prospective relations between social comparison orientation and long-term weight loss outcomes (percent weight loss, aerobic-intensity physical activity) among participants in behavioral weight loss treatment. Participants (n = 161, M Age = 54, M BMI = 34.4░kg/m 2 ) completed a measure of social comparison orientation at pre-treatment baseline. Height and weight were measured in the research center and aerobic-intensity physical activity was assessed via accelerometer at baseline, mid- and end-of-treatment, and at 6 and 12 months post-treatment (representing maintenance). Multilevel models tested prospective relations between comparison orientation and treatment outcomes over time, with emphasis on differences during the post-treatment maintenance phase. Stronger (vs. weaker) general comparison orientation was associated with better maintenance of aerobic-intensity physical activity. However, stronger (vs. weaker) orientation toward comparisons with better-off others (i.e., upward comparison) was associated with less weight loss success during and after treatment. Social comparison orientation thus shows meaningful relations with long-term maintenance of key outcomes in group-based behavioral weight loss treatment, and warrants further investigation in this context.

  18. KEY COMPARISON: Final report on CCQM-K62: Nutrients in infant/adult formula—Vitamins

    NASA Astrophysics Data System (ADS)

    Sharpless, Katherine E.; Rimmer, Catherine A.; Phinney, Karen W.; Nelson, Bryant C.; Duewer, David L.; Wise, Stephen A.; Kim, Byungjoo; Liu, Jun; Huang, Ting; Zhang, Wei

    2010-01-01

    Key comparison CCQM-K62 was designed to enable demonstration of the equivalence in capabilities for measurement of vitamins in a food matrix. A milk-based fortified human infant/adult formula was selected as the matrix based upon material availability and relevance. Because vitamins were added to the CCQM-K62 study material in a single form and at levels significantly higher than those that would be naturally occurring in the milk base, the ability of a laboratory to measure the study vitamins is only indicative of a laboratory's ability to measure vitamins in fortified foods. Target analytes were selected for study because of the ready availability of suitable standard materials and the range of their chemical properties: folic acid (vitamin B9) is a single water-soluble molecular entity that typically occurs at low levels and can be unstable, niacin (vitamin B3) is a single stable molecular entity and is typically present at higher concentrations than the other water-soluble vitamins, vitamin A has multiple molecular forms (including retinol and retinyl palmitate), is fat-soluble and typically occurs at relatively high levels. Results for participants measuring only folic acid or niacin are only indicative of their ability to make that measurement; results for participants measuring both folic acid and niacin are indicative of a laboratory's ability to measure folic acid, thiamine, niacin, and riboflavin in fortified foods but not vitamin C or other water-soluble vitamins. The ability to measure vitamin A (reported as retinol equivalents) in this material is also indicative of the participant's ability to measure vitamin E (as alpha-tocopherol and alpha-tocopheryl acetate) but is not indicative of the ability to measure vitamins D and K, which typically occur at much lower concentrations. The relative degrees of equivalence of the reported measurements for all three analytes in CCQM-K62 were within 10%; however, since only two results were submitted for niacin

  19. International comparison CCQM-K113—noble gas mixture

    NASA Astrophysics Data System (ADS)

    Lim, Jeong Sik; Lee, Jinbok; Moon, Dongmin; Tshilongo, James; Qiao, Han; Shuguo, Hu; Tiqiang, Zhang; Kelley, Michael E.; Rhoderick, George C.; Konopelko, L. A.; Kolobova, A. V.; Vasserman, I. I.; Zavyalov, S. V.; Gromova, E. V.; Efremova, O. V.

    2017-01-01

    Noble gases are one of the key elements used in the various processes of the bulbs industry, automotive industry, space industry, lasers industry, display industry as well as the semiconductor industry. Considering continuous growth, the provision of a reliable standard is required for those industries to improve their productivity. In this report, a result of the key comparison, CCQM-K113: noble gas mixture, is presented. Nominal amount-of-substance fractions of argon, neon, krypton, and xenon in helium are 20, 10, 2, and 1 cmol/mol, respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. NTP comparison process

    NASA Technical Reports Server (NTRS)

    Corban, Robert

    1993-01-01

    The systems engineering process for the concept definition phase of the program involves requirements definition, system definition, and consistent concept definition. The requirements definition process involves obtaining a complete understanding of the system requirements based on customer needs, mission scenarios, and nuclear thermal propulsion (NTP) operating characteristics. A system functional analysis is performed to provide a comprehensive traceability and verification of top-level requirements down to detailed system specifications and provides significant insight into the measures of system effectiveness to be utilized in system evaluation. The second key element in the process is the definition of system concepts to meet the requirements. This part of the process involves engine system and reactor contractor teams to develop alternative NTP system concepts that can be evaluated against specific attributes, as well as a reference configuration against which to compare system benefits and merits. Quality function deployment (QFD), as an excellent tool within Total Quality Management (TQM) techniques, can provide the required structure and provide a link to the voice of the customer in establishing critical system qualities and their relationships. The third element of the process is the consistent performance comparison. The comparison process involves validating developed concept data and quantifying system merits through analysis, computer modeling, simulation, and rapid prototyping of the proposed high risk NTP subsystems. The maximum amount possible of quantitative data will be developed and/or validated to be utilized in the QFD evaluation matrix. If upon evaluation of a new concept or its associated subsystems determine to have substantial merit, those features will be incorporated into the reference configuration for subsequent system definition and comparison efforts.

  1. Comparison versus reminding.

    PubMed

    Tullis, Jonathan G; Goldstone, Robert L

    2016-01-01

    Comparison and reminding have both been shown to support learning and transfer. Comparison is thought to support transfer because it allows learners to disregard non-matching features of superficially different episodes in order to abstract the essential structure of concepts. Remindings promote memory for the individual episodes and generalization because they prompt learners to retrieve earlier episodes during the encoding of later related episodes and to compare across episodes. Across three experiments, we compared the consequences of comparison and reminding on memory and transfer. Participants studied a sequence of related, but superficially different, proverb pairs. In the comparison condition, participants saw proverb pairs presented together and compared their meaning. In the reminding condition, participants viewed proverbs one at a time and retrieved any prior studied proverb that shared the same deep meaning as the current proverb. Experiment 1 revealed that participants in the reminding condition recalled more proverbs than those in the comparison condition. Experiment 2 showed that the mnemonic benefits of reminding persisted over a one-week retention interval. Finally, in Experiment 3, we examined the ability of participants to generalize their remembered information to new items in a task that required participants to identify unstudied proverbs that shared the same meaning as studied proverbs. Comparison led to worse discrimination between proverbs related to studied proverbs and proverbs unrelated to studied proverbs than reminding. Reminding supported better memory for individual instances and transfer to new situations than comparison.

  2. Angle comparison using an autocollimator

    NASA Astrophysics Data System (ADS)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    NASA Astrophysics Data System (ADS)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of

  4. Linking Comparisons of Absolute Gravimeters: A Proof of Concept for a new Global Absolute Gravity Reference System.

    NASA Astrophysics Data System (ADS)

    Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.

    2016-12-01

    Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.

  5. EURAMET key comparison no. EURAMET.T-K1: realisations of the ITS-90 from 2.6 K to 24.5561 K, using rhodium-iron resistance thermometers

    NASA Astrophysics Data System (ADS)

    Gaiser, Christof; Fellmuth, Bernd; Steur, Peter; Szmyrka-Grzebyk, Anna; Manuszkiewicz, Henryk; Lipinski, Leszek; Peruzzi, Andrea; Rusby, Richard; Head, David

    2017-01-01

    In the temperature range from 0.65 K to 24.5561 K, the ITS-90 is defined by specified vapour-pressure equations for 3He and 4He and interpolation equations for a constant-volume gas thermometer using 3He or 4He. The definitions are given in sections 3.1 and 3.2 of the ITS-90 text, and methods for realising the scale in this range are outlined in chapters 4 and 5 of the Guide to the Realization of the ITS-90 (formerly Supplementary Information for the ITS-90). Direct realisations of the ITS-90 by these methods require relatively sophisticated apparatus and time-consuming experiments, and consequently they are rarely carried out. The situation is acceptable in practice only because rhodium-iron resistance thermometers (RIRTs) are available that, once calibrated, are able to maintain their calibrations reliably for long periods of time. They are the practical thermometers on which realisations of the ITS-90 are most accurately maintained, disseminated and compared. The key comparison EURAMET.T-K1 is therefore a comparison of calibrated RIRTs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Paired Comparisons.

    DTIC Science & Technology

    1982-05-01

    including multidimensional scaling. Applications have arisen in many areas, but most notably in food technolog, marketing research, and sports ... competition .- An extensive bibliography on paired comparisons by Davidson and Farquhar (1976) contains some 400 references. - Paired comparisons have been...consideration of chess competition . Ford (1957) pro- posed the model independently. Both Zermelo and Ford concentrated on solution of normal equations for

  7. SUPPLEMENTARY COMPARISON Bilateral comparison on the calibrations of hydrometers for liquid density between INRIM-Italy and INMETRO-Brazil: SIM.M.D-S2

    NASA Astrophysics Data System (ADS)

    Lorefice, Salvatore; Malta, Dalni; Julio Pinheiro, José; Marteleto, Paulo Roberto

    2010-01-01

    The results of the SIM.M.D-S2 bilateral comparison between INRIM-Italy and INMETRO-Brazil are summarized in this report. The aims of this comparison were to check the stated uncertainty levels and the degrees of equivalence between the two institutes on the calibration of hydrometers for liquid density in the range of 800 kg m-3 to 1000 kg m-3 at 20 ºC, by means of two transfer standards of excellent metrological characteristics. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. An ecological momentary assessment of comparison target as a moderator of the effects of appearance-focused social comparisons.

    PubMed

    Leahey, Tricia M; Crowther, Janis H

    2008-09-01

    This research examined whether comparison target moderates the effects of naturally occurring appearance-focused social comparisons on women's affect, appearance esteem, and dieting thoughts. During daily activities, body-satisfied (BS) women and body-dissatisfied (BD) women recorded their comparison targets and reactions to comparison information. For BS women, upward comparisons with peers were associated with more positive affect (PA) and appearance esteem and less guilt than upward comparisons with media images and downward comparisons with peers were associated with less PA than downward comparisons with media images. For BD women, upward comparisons with peers were associated with more appearance esteem and diet thoughts than upward comparisons with media images and downward comparisons with peers were associated with less PA, appearance esteem, and diet thoughts and more guilt than downward comparisons with media images.

  9. Long History of IAM Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Steven J.; Clarke, Leon E.; Edmonds, James A.

    2015-04-23

    Correspondence to editor: We agree with the editors that the assumptions behind models of all types, including integrated assessment models (IAMs), should be as transparent as possible. The editors were in error, however, when they implied that the IAM community is just “now emulating the efforts of climate researchers by instigating their own model inter-comparison projects (MIPs).” In fact, model comparisons for integrated assessment and climate models followed a remarkably similar trajectory. Early General Circulation Model (GCM) comparison efforts, evolved to the first Atmospheric Model Inter-comparison Project (AMIP), which was initiated in the early 1990s. Atmospheric models evolved to coupledmore » atmosphere-ocean models (AOGCMs) and results from the first Coupled Model Inter-Comparison Project (CMIP1) become available about a decade later. Results of first energy model comparison exercise, conducted under the auspices of the Stanford Energy Modeling Forum, were published in 1977. A summary of the first comparison focused on climate change was published in 1993. As energy models were coupled to simple economic and climate models to form IAMs, the first comparison exercise for IAMs (EMF-14) was initiated in 1994, and IAM comparison exercises have been on-going since this time.« less

  10. Operating Reserves and Wind Power Integration: An International Comparison; Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milligan, M.; Donohoo, P.; Lew, D.

    2010-10-01

    This paper provides a high-level international comparison of methods and key results from both operating practice and integration analysis, based on an informal International Energy Agency Task 25: Large-scale Wind Integration.

  11. High pressure rinsing system comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Sertore; M. Fusetti; P. Michelato

    2007-06-01

    High pressure rinsing (HPR) is a key process for the surface preparation of high field superconducting cavities. A portable apparatus for the water jet characterization, based on the transferred momentum between the water jet and a load cell, has been used in different laboratories. This apparatus allows to collected quantitative parameters that characterize the HPR water jet. In this paper, we present a quantitative comparison of the different water jet produced by various nozzles routinely used in different laboratories for the HPR process

  12. SUPPLEMENTARY COMPARISON: Report of the bilateral comparison of the calibrations of hydrometers for liquid density determination between CENAM-Mexico and INRIM-Italy: SIM.M.D-S1

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Lorefice, Salvatore

    2009-01-01

    Hydrometers are instruments usually made of glass which are widely used for different levels of precision to measure liquid density and related quantities to control different products and processes. This bilateral comparison on the calibration of hydrometers shows that results reported by CENAM-Mexico and INRIM-Italy are consistent within the claimed uncertainty in the range of 800 kg/m3 to 1200 kg/m3. This bilateral comparison is intended to link the two regional comparisons SIM.M.D-K4 and EURAMET.D-K4. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Final report on international comparison CCQM-K83: Halocarbons in dry whole air

    NASA Astrophysics Data System (ADS)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Moon, Dongmin; Lee, Jinbok; Lim, Jeongsik; Seog Kim, Jin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a key comparison for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2 trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2 tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. International documentary standards and comparison of national physical measurement standards for the calibration of accelerometers

    NASA Astrophysics Data System (ADS)

    Evans, David J.

    2002-11-01

    The documentary standards defining internationally adopted methodologies and protocols for calibrating transducers used to measure vibration are currently developed under the International Organization for Standardization (ISO) Technical Committee 108 Sub Committee 3 (Use and calibration of vibration and shock measuring instruments). Recent revisions of the documentary standards on primary methods for the calibration of accelerometers used to measure rectilinear motion have been completed. These standards can be, and have been, used as references in the technical protocols of key international and regional comparisons between National Measurement Institutes (NMIs) on the calibration of accelerometers. These key comparisons are occurring in part as a result of the creation of the Mutual Recognition Arrangement between NMIs which has appendices that document the uncertainties, and the comparisons completed in support of the uncertainties, claimed by the National Laboratories that are signatories of the MRA. The measurements for the first international and the first Interamerican System of Metrology (SIM) regional key comparisons in vibration have been completed. These intercomparisons were promulgated via the relatively new Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM) and SIM Metrology Working Group (MWG) 9, respectively.

  15. Enabling interspecies epigenomic comparison with CEpBrowser.

    PubMed

    Cao, Xiaoyi; Zhong, Sheng

    2013-05-01

    We developed the Comparative Epigenome Browser (CEpBrowser) to allow the public to perform multi-species epigenomic analysis. The web-based CEpBrowser integrates, manages and visualizes sequencing-based epigenomic datasets. Five key features were developed to maximize the efficiency of interspecies epigenomic comparisons. CEpBrowser is a web application implemented with PHP, MySQL, C and Apache. URL: http://www.cepbrowser.org/.

  16. FIELD MEASUREMENT OF DISSOLVED OXYGEN: A COMPARISON OF METHODS

    EPA Science Inventory

    The ability to confidently measure the concentration of dissolved oxygen (D.O.) in ground water is a key aspect of remedial selection and assessment. Presented here is a comparison of the commonly practiced methods for determining D.O. concentrations in ground water, including c...

  17. KEY COMPARISON: Final report on CCQM-K63.a,b: Non-peptide hormones in serum: cortisol and progesterone

    NASA Astrophysics Data System (ADS)

    S-C Tai, Susan; Duewer, David L.

    2010-01-01

    Hormones are chemical messengers that regulate many life functions. Deviations from normal hormone levels can have serious health consequences. Accurate measurement of hormone levels in serum can be beneficial in diagnosing, monitoring, and treating a number of diseases. Two steroid hormones, cortisol and progesterone, were selected by the Organic Analysis Working Group (OAWG) to evaluate its member Institutes' measurement capabilities for this important class of measurand. Serum concentrations of cortisol range from 30 ng/mL to 230 ng/mL. Serum concentrations of progesterone in adult females range from 0.15 ng/mL to 25 ng/mL but can rise to approx230 ng/mL during pregnancy. The ability to measure cortisol is indicative of a laboratory's ability to measure steroid hormones at concentration levels similar to cortisol. The ability to measure progesterone is indicative of a laboratory's ability to measure steroid hormones with similar functional groups and concentration levels, such as testosterone. Pilot studies CCQM-P77.a and CCQM-P77.b on the determination of cortisol and progesterone in human serum were completed in 2006. There was good agreement among the results reported by participants who used isotope dilution/mass spectrometry (ID/MS) with either gas chromatography (GC) or liquid chromatography (LC). In 2007 the OAWG decided to proceed with key comparison (KC) CCQM-K63.a, cortisol in human serum, and CCQM-K63.b, progesterone in human serum. Thus, following established OAWG procedure, only results from participants that (1) used an ID/MS-based method, (2) participated in the relevant pilot study, and (3) used a metrologically traceable primary standard were to be eligible for use in calculating the key comparison reference value (KCRV) for each measurand. Six laboratories participated in CCQM-K63.a and eight laboratories participated in CCQM-K63.b. The same pooled frozen female serum material was used in both of the KCs. The mean value for the six ID

  18. The matrix: A comparison of international wilderness laws

    Treesearch

    Peter Landres; Brad Barr; Cyril F. Kormos

    2008-01-01

    The following matrix provides a comparison of wilderness laws around the world. This matrix is divided into four parts, each focusing on a key area of wilderness legislation: the definition of wilderness; the overall legislative purpose; uses allowed by the legislation; and administration and management requirements under law. A more thorough analysis of individual...

  19. "Harder, Better, Faster, Stronger": Negative Comparison on Facebook and Adolescents' Life Satisfaction Are Reciprocally Related.

    PubMed

    Frison, Eline; Eggermont, Steven

    2016-03-01

    Social networking sites, such as Facebook, offer adolescent users an ideal platform for negative comparison (i.e., experiencing negative feelings from social comparison). Although such negative comparison on Facebook has been associated with users' well-being, the reciprocal relations between the two remain unclear, particularly in an adolescent sample. To examine this reciprocal process, a two-wave study among a representative sample of Flemish adolescents was set up (N Time1 = 1,840). Data were analyzed using structural equation modeling. Cross-lagged analyses indicated that negative comparison on Facebook predicted decreases in life satisfaction over time. Conversely, lower scores on life satisfaction predicted increases in negative comparison on Facebook. The discussion focuses on the understanding of these findings, key limitations, directions for future research, and implications for prevention and intervention strategies.

  20. The neural correlates of beauty comparison

    PubMed Central

    Mussweiler, Thomas; Mullins, Paul; Linden, David E. J.

    2014-01-01

    Beauty is in the eye of the beholder. How attractive someone is perceived to be depends on the individual or cultural standards to which this person is compared. But although comparisons play a central role in the way people judge the appearance of others, the brain processes underlying attractiveness comparisons remain unknown. In the present experiment, we tested the hypothesis that attractiveness comparisons rely on the same cognitive and neural mechanisms as comparisons of simple nonsocial magnitudes such as size. We recorded brain activity with functional magnetic resonance imaging (fMRI) while participants compared the beauty or height of two women or two dogs. Our data support the hypothesis of a common process underlying these different types of comparisons. First, we demonstrate that the distance effect characteristic of nonsocial comparisons also holds for attractiveness comparisons. Behavioral results indicated, for all our comparisons, longer response times for near than far distances. Second, the neural correlates of these distance effects overlapped in a frontoparietal network known for its involvement in processing simple nonsocial quantities. These results provide evidence for overlapping processes in the comparison of physical attractiveness and nonsocial magnitudes. PMID:23508477

  1. The neural correlates of beauty comparison.

    PubMed

    Kedia, Gayannée; Mussweiler, Thomas; Mullins, Paul; Linden, David E J

    2014-05-01

    Beauty is in the eye of the beholder. How attractive someone is perceived to be depends on the individual or cultural standards to which this person is compared. But although comparisons play a central role in the way people judge the appearance of others, the brain processes underlying attractiveness comparisons remain unknown. In the present experiment, we tested the hypothesis that attractiveness comparisons rely on the same cognitive and neural mechanisms as comparisons of simple nonsocial magnitudes such as size. We recorded brain activity with functional magnetic resonance imaging (fMRI) while participants compared the beauty or height of two women or two dogs. Our data support the hypothesis of a common process underlying these different types of comparisons. First, we demonstrate that the distance effect characteristic of nonsocial comparisons also holds for attractiveness comparisons. Behavioral results indicated, for all our comparisons, longer response times for near than far distances. Second, the neural correlates of these distance effects overlapped in a frontoparietal network known for its involvement in processing simple nonsocial quantities. These results provide evidence for overlapping processes in the comparison of physical attractiveness and nonsocial magnitudes.

  2. Pairwise-Comparison Software

    NASA Technical Reports Server (NTRS)

    Ricks, Wendell R.

    1995-01-01

    Pairwise comparison (PWC) is computer program that collects data for psychometric scaling techniques now used in cognitive research. It applies technique of pairwise comparisons, which is one of many techniques commonly used to acquire the data necessary for analyses. PWC administers task, collects data from test subject, and formats data for analysis. Written in Turbo Pascal v6.0.

  3. Importance of the nature of comparison conditions for testing theory-based interventions: reply.

    PubMed

    Michie, Susan; Prestwich, Andrew; de Bruin, Marijn

    2010-09-01

    The nature of comparison conditions is a much overlooked feature of designing and interpreting the results of randomized controlled trials, as outlined by Williams (see record 2010-18776-001). We agree that understanding the components and mechanisms of the comparison condition is necessary for making inferences about both intervention effectiveness (whether the intervention worked and which components may have contributed to such an effect) and about theoretical mediators (how it worked). The extent to which one can draw strong inferences regarding the efficacy and mechanisms of an intervention over the comparison is conditional upon a number of key points. (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  4. International comparison of activity measurements of a solution of 238Pu

    NASA Astrophysics Data System (ADS)

    Ratel, G.; Michotte, C.

    2018-01-01

    This report concerns an international comparison of measurements of a solution of 238Pu that was carried out by 12 participants in 2001. The report includes the degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Final report on the key comparison, CCM.M.P-K15.1 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Hongyan, Yu

    2017-01-01

    At the CCM WG-LP meeting in Berlin in April 2011 the National Institute of Metrology of the people's republic of China asked for an opportunity to be linked to the CCM.M.P-K15 comparison which just ended. METAS, which had been active as pilot for the CCM.M.P-K15, agreed to make a link with NIM. The NIM introduced a new static expansion system in his laboratory. Two spinning rotor gauges and a control electronic are used as transfer standard. The circulation of the transfer standard was made in spring 2012. The drift of the accommodation coefficient of the two SRG was measured by the pilot before and after the comparison. The stability of the transfer standards was excellent and the equivalence between METAS and NIM has been demonstrated. A link to the CCM.M.P­K15 has been established using the results from METAS. It has been possible to achieve a link with a small uncertainty due to the strong correlation of the measurements of METAS in the two comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final report on the Seventh International Comparison of Absolute Gravimeters (ICAG 2005)

    USGS Publications Warehouse

    Jiang, Z.; Francis, O.; Vitushkin, L.; Palinkas, V.; Germak, A.; Becker, M.; D'Agostino, G.; Amalvict, M.; Bayer, R.; Bilker-Koivula, M.; Desogus, S.; Faller, J.; Falk, R.; Hinderer, J.; Gagnon, C.; Jakob, T.; Kalish, E.; Kostelecky, J.; Lee, C.; Liard, J.; Lokshyn, Y.; Luck, B.; Makinen, J.; Mizushima, S.; Le, Moigne N.; Origlia, C.; Pujol, E.R.; Richard, P.; Robertsson, L.; Ruess, D.; Schmerge, D.; Stus, Y.; Svitlov, S.; Thies, S.; Ullrich, C.; Van Camp, M.; Vitushkin, A.; Ji, W.; Wilmes, H.

    2011-01-01

    The Bureau International des Poids et Mesures (BIPM), S??vres, France, hosted the 7th International Comparison of Absolute Gravimeters (ICAG) and the associated Relative Gravity Campaign (RGC) from August to September 2005. ICAG 2005 was prepared and performed as a metrological pilot study, which aimed: To determine the gravity comparison reference values; To determine the offsets of the absolute gravimeters; and As a pilot study to accumulate experience for the CIPM Key Comparisons. This document presents a complete and extensive review of the technical protocol and data processing procedures. The 1st ICAG-RGC comparison was held at the BIPM in 1980-1981 and since then meetings have been organized every 4 years. In this paper, we present an overview of how the meeting was organized, the conditions of BIPM gravimetric sites, technical specifications, data processing strategy and an analysis of the final results. This 7th ICAG final report supersedes all previously published reports. Readings were obtained from participating instruments, 19 absolute gravimeters and 15 relative gravimeters. Precise levelling measurements were carried out and all measurements were performed on the BIPM micro-gravity network which was specifically designed for the comparison. ?? 2011 BIPM & IOP Publishing Ltd.

  7. ECTA/DaSy Framework Self-Assessment Comparison Tool

    ERIC Educational Resources Information Center

    Center for IDEA Early Childhood Data Systems (DaSy), 2016

    2016-01-01

    The Self-Assessment Comparison (SAC) Tool is for state Part C and Section 619/Preschool programs to use to assess changes in the implementation of one or more components of the ECTA System Framework and/or subcomponenets of the DaSy Data System Framework. It is a companion to the ECTA/DaSy Framework Self-Assessment. Key features of the SAC are…

  8. APMP comparison on luminous flux units (APMP.PR-K4)

    NASA Astrophysics Data System (ADS)

    Liu, H.; Lin, Y. D.; Yang, C. Z.; Yu, J.

    2018-01-01

    During the 18th APMP meeting in 2004, TCPR agreed that the luminous flux should be one of the several regional comparisons to be conducted in the field of photometry and radiometry, and the project was named as APMP.PR-K4. Nine laboratories took part in this comparison. A group of LF 200W lamps (no less than three) was used as transfer artifacts by each participant. The National Institute of Metrology (NIM, China) acted as the pilot laboratory. Presented in this report are the detailed procedures and results of the work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report of the key comparison CCQM-K98: Pb isotope amount ratios in bronze

    NASA Astrophysics Data System (ADS)

    Vogl, Jochen; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Goenaga-Infante, Heidi; Malinowskiy, Dmitriy; Ren, Tongxiang; Wang, Jun; Vocke, Robert D., Jr.; Murphy, Karen; Nonose, Naoko; Rienitz, Olaf; Noordmann, Janine; Näykki, Teemu; Sara-Aho, Timo; Ari, Betül; Cankur, Oktay

    2014-01-01

    Isotope amount ratios are proving useful in an ever increasing array of applications that range from studies unravelling transport processes, to pinpointing the provenance of specific samples as well as trace element quantification by using isotope dilution mass spectrometry (IDMS). These expanding applications encompass fields as diverse as archaeology, food chemistry, forensic science, geochemistry, medicine and metrology. However, to be effective tools, the isotope ratio data must be reliable and traceable to enable the comparability of measurement results. The importance of traceability and comparability in isotope ratio analysis has already been recognized by the Inorganic Analysis Working Group (IAWG) within the CCQM. While the requirements for isotope ratio accuracy and precision in the case of IDMS are generally quite modest, 'absolute' Pb isotope ratio measurements for geochemical applications as well as forensic provenance studies require Pb isotope ratio measurements of the highest quality. To support present and future CMCs on isotope ratio determinations, a key comparison was urgently needed and therefore initiated at the IAWG meeting in Paris in April 2011. The analytical task within such a comparison was decided to be the measurement of Pb isotope amount ratios in water and bronze. Measuring Pb isotope amount ratios in an aqueous Pb solution tested the ability of analysts to correct for any instrumental effects on the measured ratios, while the measurement of Pb isotope amount ratios in a metal matrix sample provided a real world test of the whole chemical and instrumental procedure. A suitable bronze material with a Pb mass fraction between 10 and 100 mg•kg-1 and a high purity solution of Pb with a mass fraction of approximately 100 mg•kg-1 was available at the pilot laboratory (BAM), both offering a natural-like Pb isotopic composition. The mandatory measurands, the isotope amount ratios n(206Pb)/n(204Pb), n(207Pb)/n(204Pb) and n(208Pb)/n(204Pb

  10. Comparison of measurement standards of the acoustic pressure in air in the low frequency range: COOMET.AUV.A-K2

    NASA Astrophysics Data System (ADS)

    Chalyy, V.

    2011-01-01

    A bilateral regional comparison of national microphone standards from 2 Hz to 250 Hz was carried out between the DP NDI 'Systema' (Ukraine) and the VNIIFTRI (Russia) from July to September 2009. The comparison, COOMET.AUV.A-K2, was based on the pressure calibration of laboratory standard microphones type LSIP. The comparison results have been linked to the established key comparison reference value (KCRV) of CCAUV.A-K2. The degrees of equivalence, expressed as the deviation from the established KCRV and its expanded uncertainty (k = 2), have been determined, and the comparison result is in agreement with the KCRV within the estimated uncertainties at all employed frequencies. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. Final report on EURAMET.L-S21: `Supplementary comparison of parallel thread gauges'

    NASA Astrophysics Data System (ADS)

    Mudronja, Vedran; Šimunovic, Vedran; Acko, Bojan; Matus, Michael; Bánréti, Edit; István, Dicso; Thalmann, Rudolf; Lassila, Antti; Lillepea, Lauri; Bartolo Picotto, Gian; Bellotti, Roberto; Pometto, Marco; Ganioglu, Okhan; Meral, Ilker; Salgado, José Antonio; Georges, Vailleau

    2015-01-01

    The results of the comparison of parallel thread gauges between ten European countries are presented. Three thread plugs and three thread rings were calibrated in one loop. Croatian National Laboratory for Length (HMI/FSB-LPMD) acted as the coordinator and pilot laboratory of the comparison. Thread angle, thread pitch, simple pitch diameter and pitch diameter were measured. Pitch diameters were calibrated within 1a, 2a, 1b and 2b calibration categories in accordance with the EURAMET cg-10 calibration guide. A good agreement between the measurement results and differences due to different calibration categories are analysed in this paper. This comparison was a first EURAMET comparison of parallel thread gauges based on the EURAMET ctg-10 calibration guide, and has made a step towards the harmonization of future comparisons with the registration of CMC values for thread gauges. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Matched Comparison Group Design Standards in Systematic Reviews of Early Childhood Interventions.

    PubMed

    Thomas, Jaime; Avellar, Sarah A; Deke, John; Gleason, Philip

    2017-06-01

    Systematic reviews assess the quality of research on program effectiveness to help decision makers faced with many intervention options. Study quality standards specify criteria that studies must meet, including accounting for baseline differences between intervention and comparison groups. We explore two issues related to systematic review standards: covariate choice and choice of estimation method. To help systematic reviews develop/refine quality standards and support researchers in using nonexperimental designs to estimate program effects, we address two questions: (1) How well do variables that systematic reviews typically require studies to account for explain variation in key child and family outcomes? (2) What methods should studies use to account for preexisting differences between intervention and comparison groups? We examined correlations between baseline characteristics and key outcomes using Early Childhood Longitudinal Study-Birth Cohort data to address Question 1. For Question 2, we used simulations to compare two methods-matching and regression adjustment-to account for preexisting differences between intervention and comparison groups. A broad range of potential baseline variables explained relatively little of the variation in child and family outcomes. This suggests the potential for bias even after accounting for these variables, highlighting the need for systematic reviews to provide appropriate cautions about interpreting the results of moderately rated, nonexperimental studies. Our simulations showed that regression adjustment can yield unbiased estimates if all relevant covariates are used, even when the model is misspecified, and preexisting differences between the intervention and the comparison groups exist.

  13. Comparison APMP.QM-S2.1: oxygen in nitrogen at atmospheric level

    NASA Astrophysics Data System (ADS)

    Kim, B. M.; Kim, K.; Jung, J.; Oh, S.; Hui, L.; Li, H.; Keat, T. B.; Ann, C. H.

    2016-01-01

    This document describes results of the bilateral comparison of an oxygen in nitrogen gas mixture. The nominal amount-of-substance fraction was 0.2 mol/mol oxygen in nitrogen Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Acquisition of Comparison Constructions

    ERIC Educational Resources Information Center

    Hohaus, Vera; Tiemann, Sonja; Beck, Sigrid

    2014-01-01

    This article presents a study on the time course of the acquisition of comparison constructions. The order in which comparison constructions (comparatives, measure phrases, superlatives, degree questions, etc.) show up in English- and German-learning children's spontaneous speech is quite fixed. It is shown to be insufficiently determined by…

  15. Comparison on the calibrations of hydrometers for liquids density determination between SIM laboratories

    NASA Astrophysics Data System (ADS)

    Morales, Abed; Quiroga, Aldo; Daued, Arturo; Cantero, Diana; Sequeira, Francisco; Castro, Luis Carlos; Becerra, Luis Omar; Salazar, Manuel; Vega, Maria

    2017-01-01

    A supplementary comparison was made between SIM laboratories concerning the calibration of four hydrometers within the range of 600 kg/m3 to 2000 kg/m3. The main objectives of the comparison were to evaluate the degree of equivalences SIM NMIs in the calibration of hydrometers of high accuracy. The participant NMIs were: CENAM, IBMETRO, INEN, INDECOPI, INM, INTN and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Finding faults: analogical comparison supports spatial concept learning in geoscience.

    PubMed

    Jee, Benjamin D; Uttal, David H; Gentner, Dedre; Manduca, Cathy; Shipley, Thomas F; Sageman, Bradley

    2013-05-01

    A central issue in education is how to support the spatial thinking involved in learning science, technology, engineering, and mathematics (STEM). We investigated whether and how the cognitive process of analogical comparison supports learning of a basic spatial concept in geoscience, fault. Because of the high variability in the appearance of faults, it may be difficult for students to learn the category-relevant spatial structure. There is abundant evidence that comparing analogous examples can help students gain insight into important category-defining features (Gentner in Cogn Sci 34(5):752-775, 2010). Further, comparing high-similarity pairs can be especially effective at revealing key differences (Sagi et al. 2012). Across three experiments, we tested whether comparison of visually similar contrasting examples would help students learn the fault concept. Our main findings were that participants performed better at identifying faults when they (1) compared contrasting (fault/no fault) cases versus viewing each case separately (Experiment 1), (2) compared similar as opposed to dissimilar contrasting cases early in learning (Experiment 2), and (3) viewed a contrasting pair of schematic block diagrams as opposed to a single block diagram of a fault as part of an instructional text (Experiment 3). These results suggest that comparison of visually similar contrasting cases helped distinguish category-relevant from category-irrelevant features for participants. When such comparisons occurred early in learning, participants were more likely to form an accurate conceptual representation. Thus, analogical comparison of images may provide one powerful way to enhance spatial learning in geoscience and other STEM disciplines.

  17. Results of the EURAMET.RI(II)-S6.I-129 supplementary comparison

    NASA Astrophysics Data System (ADS)

    García-Toraño, Eduardo; Altzitzoglou, Timotheos; Auerbach, Pavel; Bé, Marie-Martine; Lourenço, Valérie; Bobin, Christophe; Cassette, Philippe; Dersch, Rainer; Kossert, Karsten; Nähle, Ole; Peyrés, Virginia; Pommé, Stefaan; Rozkov, Andrej; Sanchez-Cabezudo, Anabel; Sochoro&vacute; , Jana

    2015-01-01

    An international comparison of the long-lived gamma-ray emitter 129I has been recently completed. A total of 5 laboratories measured a solution prepared by Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT). Aliquots of the master solution were standardized in terms of activity per mass unit by participant laboratories using 4 different techniques. The results of the comparison can be used as the basis for establishing the equivalence among the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Visual Color Comparisons in Forensic Science.

    PubMed

    Thornton, J I

    1997-06-01

    Color is used extensively in forensic science for the characterization and comparison of physical evidence, and should thus be well understood. Fundamental elements of color perception and color comparison systems are first reviewed. The second portion of this article discusses instances in which defects in color perception may occur, and the recognition of opportunities by means of which color perception and color discrimination may be expressed and enhanced. Application and limitations of color comparisons in forensic science, including soil, paint, and fibers comparisons and color tests, are reviewed. Copyright © 1997 Central Police University.

  19. Is Comparison the Thief of Joy? Sexual Narcissism and Social Comparisons in the Domain of Sexuality.

    PubMed

    Day, Lisa C; Muise, Amy; Impett, Emily A

    2017-02-01

    Are people who are high in sexual narcissism more sensitive to information comparing their sex lives with the sex lives of others? Does this sensitivity explain narcissists' lower sexual and relationship satisfaction? We conducted three studies to address this question. Participants completed the Sexual Narcissism Scale (Widman & McNulty, 2010), and then either recalled (Study 1), imagined (Study 2), or actually made (Study 3) a sexual comparison. We found that people high in sexual narcissism (compared with those lower in sexual narcissism) were more bothered when comparing themselves with someone with a higher sexual frequency and felt better about a comparison with someone with a lower sexual frequency. In turn, narcissists' greater sensitivity to upward social comparisons predicted lower sexual and relationship satisfaction. These results suggest that those high in sexual narcissism may use downward sexual comparisons to maintain their grandiose self-views and be particularly sensitive to upward sexual comparisons.

  20. Comparison of density determination of liquid samples by density meters

    NASA Astrophysics Data System (ADS)

    Buchner, C.; Wolf, H.; Vámossy, C.; Lorefice, S.; Lenard, E.; Spohr, I.; Mares, G.; Perkin, M.; Parlic-Risovic, T.; Grue, L.-L.; Tammik, K.; van Andel, I.; Zelenka, Z.

    2016-01-01

    Hydrostatic density determinations of liquids as reference material are mainly performed by National Metrology Institutes to provide means for calibrating or checking liquid density measuring instruments such as oscillation-type density meters. These density meters are used by most of the metrology institutes for their calibration and scientific work. The aim of this project was to compare the results of the liquid density determination by oscillating density meters of the participating laboratories. The results were linked to CCM.D.K-2 partly via Project EURAMET.M.D.K-2 (1019) "Comparison of liquid density standards" by hydrostatic weighing piloted by BEV in 2008. In this comparison pentadecane, water and of oil with a high viscosity were measured at atmospheric pressure using oscillation type density meter. The temperature range was from 15 °C to 40 °C. The measurement results were in some cases discrepant. Further studies, comparisons are essential to explore the capability and uncertainty of the density meters Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Reinforcer Control by Comparison-Stimulus Color and Location in a Delayed Matching-to-Sample Task

    ERIC Educational Resources Information Center

    Alsop, Brent; Jones, B. Max

    2008-01-01

    Six pigeons were trained in a delayed matching-to-sample task involving bright- and dim-yellow samples on a central key, a five-peck response requirement to either sample, a constant 1.5-s delay, and the presentation of comparison stimuli composed of red on the left key and green on the right key or vice versa. Green-key responses were…

  2. Quantum-state comparison and discrimination

    NASA Astrophysics Data System (ADS)

    Hayashi, A.; Hashimoto, T.; Horibe, M.

    2018-05-01

    We investigate the performance of discrimination strategy in the comparison task of known quantum states. In the discrimination strategy, one infers whether or not two quantum systems are in the same state on the basis of the outcomes of separate discrimination measurements on each system. In some cases with more than two possible states, the optimal strategy in minimum-error comparison is that one should infer the two systems are in different states without any measurement, implying that the discrimination strategy performs worse than the trivial "no-measurement" strategy. We present a sufficient condition for this phenomenon to happen. For two pure states with equal prior probabilities, we determine the optimal comparison success probability with an error margin, which interpolates the minimum-error and unambiguous comparison. We find that the discrimination strategy is not optimal except for the minimum-error case.

  3. SUPPLEMENTARY COMPARISON: Final report on supplementary comparison APMP-T-S3-03 of industrial platinum resistance and liquid in glass thermometers from -40 °C to 250 °C

    NASA Astrophysics Data System (ADS)

    Norranim, Uthai; Nguyen, Mong Kim; Ballico, Mark J.

    2007-01-01

    Industrial thermometers such as industrial platinum resistance thermometers (iprts) and liquid-in-glass thermometers (LIGTs) are widely used in industry. Because Key Comparisons are limited to direct realizations of ITS-90, and not all APMP NMIs have participated in them, the national metrology institutes (NMIs) of Thailand and Australia (NIMT and NIMA) organized an APMP supplementary comparison to support the approval of CMCs (calibration and measurement capabilities) for these laboratories. The comparison, performed in 2003, covered the range from -40.0 °C to 250.0 °C, using IPRTs (Hart Scientific 5626-12-S), total immersion (ASTM 62C, 120C) and partial immersion (ASTM 40C) LIGTs. Ten NMIs from the APMP: KIM-LIPI (Indonesia), ITDI (Philippines), MSL (New Zealand), NBSM (Nepal), NMIA (Australia), NIMT (Thailand), SCL (Hong Kong), SIRIM (Malaysia), SPRING (Singapore) and VMI (Vietnam) were divided into two loops to shorten the circulation time, and these were linked by the two pilot laboratories. This report describes details of the artifacts, the circulation schedule, the measurement procedures, the results submitted by participants, uncertainties and the analysis of the results. Reference values calculated using simple mean, median and weighted mean were consistent with each other, but as the Birge criterion was satisfied, the weighted mean with its lower uncertainty was adopted. The artifacts were found to be stable over the comparison and the results of the loop linking labs consistent, allowing an uncertainty of 2 mK to 4 mK to be achieved for the IPRT reference value and 10 mK to 20 mK for the LIGT reference values. These uncertainties allowed the comparison data to be used to adequately test the uncertainties of all the participant laboratories, and hence to directly support their CMC claims. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database

  4. Final report of the SIM.QM-S8 supplementary comparison, trace metals in drinking water

    NASA Astrophysics Data System (ADS)

    Yang, Lu; Nadeau, Kenny; Gedara Pihillagawa, Indu; Meija, Juris; Mester, Zoltan; Napoli, Romina; Pérez Zambra, Ramiro; Ferreira, Elizabeth; Alejandro Ahumada Forigua, Diego; Abella Gamba, Johanna Paola

    2018-01-01

    After completing a supplementary comparison SIM.QM-S7, the National Metrology Institute of Colombia (NMIC) requested to National Research Council of Canada (NRC) a subsequent bilateral comparison, because INMC considered that its results in SIM.QM-S7 unrepresentative of its standards. In this context, NRC agreed to coordinate this bilateral comparison with the aim of demonstrating the measurement capabilities of trace elements in fresh water. Participants included NMIC and LATU. No measurement method was prescribed by the coordinating laboratory. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S8 Supplementary Comparison provides NMIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. International comparison CCQM-K119 liquefied petroleum gas

    NASA Astrophysics Data System (ADS)

    Brewer, P. J.; Downey, M. L.; Atkins, E.; Brown, R. J. C.; Brown, A. S.; Zalewska, E. T.; van der Veen, A. M. H.; Smeulders, D. E.; McCallum, J. B.; Satumba, R. T.; Kim, Y. D.; Kang, N.; Bae, H. K.; Woo, J. C.; Konopelko, L. A.; Popova, T. A.; Meshkov, A. V.; Efremova, O. V.; Kustikov, Y.

    2018-01-01

    Liquefied hydrocarbon mixtures with traceable composition are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas), thus meeting the needs of an increasingly large industrial market. This comparison aims to assess the analytical capabilities of laboratories for measuring the composition of a Liquid Petroleum Gas (LPG) mixture when sampled in the liquid phase from a Constant Pressure Cylinder. Mixtures contained ethane, propane, propene, i-butane, n-butane, but-1-ene and i-pentane with nominal amount fractions of 2, 71, 9, 4, 10, 3 and 1 cmol mol-1 respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Physical similarity or numerical representation counts in same-different, numerical comparison, physical comparison, and priming tasks?

    PubMed

    Zhang, Li; Xin, Ziqiang; Feng, Tingyong; Chen, Yinghe; Szűcs, Denes

    2018-03-01

    Recent studies have highlighted the fact that some tasks used to study symbolic number representations are confounded by judgments about physical similarity. Here, we investigated whether the contribution of physical similarity and numerical representation differed in the often-used symbolic same-different, numerical comparison, physical comparison, and priming tasks. Experiment 1 showed that subjective physical similarity was the best predictor of participants' performance in the same-different task, regardless of simultaneous or sequential presentation. Furthermore, the contribution of subjective physical similarity was larger in a simultaneous presentation than in a sequential presentation. Experiment 2 showed that only numerical representation was involved in numerical comparison. Experiment 3 showed that both subjective physical similarity and numerical representation contributed to participants' physical comparison performance. Finally, only numerical representation contributed to participants' performance in a priming task as revealed by Experiment 4. Taken together, the contribution of physical similarity and numerical representation depends on task demands. Performance primarily seems to rely on numerical properties in tasks that require explicit quantitative comparison judgments (physical or numerical), while physical stimulus properties exert an effect in the same-different task.

  7. The current status of microscopical hair comparisons.

    PubMed

    Rowe, W F

    2001-12-08

    Although the microscopical comparison of human hairs has been accepted in courts of law for over a century, recent advances in DNA technology have called this type of forensic examination into question. In a number of cases, post-conviction DNA testing has exonerated defendants who were convicted in part on the results of microscopical hair comparisons. A federal judge has held a Daubert hearing on the microscopical comparison of human hairs and has concluded that this type of examination does not meet the criteria for admission of scientific evidence in federal courts. A review of the available scientific literature on microscopical hair comparisons (including studies conducted by the Royal Canadian Mounted Police and the Federal Bureau of Investigation) leads to three conclusions: (1) microscopical comparisons of human hairs can yield scientifically defensible conclusions that can contribute to criminal investigations and criminal prosecutions, (2) the reliability of microscopical hair comparisons is strongly affected by the training of the forensic hair examiner, (3) forensic hair examiners cannot offer estimates of the probability of a match of a questioned hair with a hair from a randomly selected person. In order for microscopical hair examinations to survive challenges under the U.S. Supreme Court's Daubert decision, hair microscopists must be better trained and undergo frequent proficiency testing. More research on the error rates of microscopical hair comparisons should be undertaken, and guidelines for the permissible interpretations of such comparisons should be established. Until these issues have been addressed and satisfactorily resolved, microscopical hair comparisons should be regarded by law enforcement agencies and courts of law as merely presumptive in nature, and all microscopical hair comparisons should be confirmed by nuclear DNA profiling or mitochondrial DNA sequencing.

  8. Case Comparisons: An Efficient Way of Learning Radiology.

    PubMed

    Kok, Ellen M; de Bruin, Anique B H; Leppink, Jimmie; van Merriënboer, Jeroen J G; Robben, Simon G F

    2015-10-01

    Radiologists commonly use comparison films to improve their differential diagnosis. Educational literature suggests that this technique might also be used to bolster the process of learning to interpret radiographs. We investigated the effectiveness of three comparison techniques in medical students, whom we invited to compare cases of the same disease (same-disease comparison), cases of different diseases (different-disease comparison), disease images with normal images (disease/normal comparison), and identical images (no comparison/control condition). Furthermore, we used eye-tracking technology to investigate which elements of the two cases were compared by the students. We randomly assigned 84 medical students to one of four conditions and had them study different diseases on chest radiographs, while their eye movements were being measured. Thereafter, participants took two tests that measured diagnostic performance and their ability to locate diseases, respectively. Students studied most efficiently in the same-disease and different-disease comparison conditions: test 1, F(3, 68) = 3.31, P = .025, ηp(2) = 0.128; test 2, F(3, 65) = 2.88, P = .043, ηp(2) = 0.117. We found that comparisons were effected in 91% of all trials (except for the control condition). Comparisons between normal anatomy were particularly common (45.8%) in all conditions. Comparing cases can be an efficient way of learning to interpret radiographs, especially when the comparison technique used is specifically tailored to the learning goal. Eye tracking provided insight into the comparison process, by showing that few comparisons were made between abnormalities, for example. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  9. Social comparison modulates reward-driven attentional capture.

    PubMed

    Jiao, Jun; Du, Feng; He, Xiaosong; Zhang, Kan

    2015-10-01

    It is well established that attention can be captured by task irrelevant and non-salient objects associated with value through reward learning. However, it is unknown whether social comparison influences reward-driven attentional capture. The present study created four social contexts to examine whether different social comparisons modulate the reward-driven capture of attention. The results showed that reward-driven attentional capture varied with different social comparison conditions. Most prominently, reward-driven attentional capture is dramatically reduced in the disadvantageous social comparison context, in which an individual is informed that the other participant is earning more monetary reward for performing the same task. These findings suggest that social comparison can affect the reward-driven capture of attention.

  10. APMP supplementary comparison (APMP.L-S8) measurement of flatness of optical flat by interferometry

    NASA Astrophysics Data System (ADS)

    Buajarern, J.; Bitou, Y.; Zi, X.; Zhao, L.; Swift, N.; Agarwal, A.; Hungwe, F.

    2018-01-01

    A reginal supplementary comparison, APMP.L-S8, was started in 2015 to demonstrate the equivalence of routine calibration services offered by NMIs to clients. Participants in this APMP.L-S8 comparison agreed to apply interferometric method for flatness measurement of the optical flats. There are two configurations of flatness interferometer used in this comparison, vertical type and horizontal type. There are seven laboratories from NMIs participated this supplementary comparison which included NIMT, NMIJ, NIM, NMC/A*STAR, MSL, NPLI and NMISA. This report describes the measurement results of two optical flats, diameter of 70 mm and 160 mm. The calibrations of this comparison were carried out by participants during the period from July 2015 to September 2016. The results show that there is a degree of equivalence below 1 for all measurands. Hence, there is a close agreement between the measurements from all participants. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Bilateral Comparison Between NIM and NMC Over the Temperature Range from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Sun, Jianping; Ye, Shaochun; Kho, Haoyuan; Zhang, Jintao; Wang, Li

    2015-08-01

    A bilateral comparison of local realization of the International Temperature Scale of 1990 between the National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from 83.8058 K to 692.677 K. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin, and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key Comparison 3 (CCT-K3) and facilitate the NMC's calibration and measurement capabilities submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme in 2009, and registered in the Key Comparison Database in 2010 as CCT-K3.2. NMC supplied two fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn, and Zn fixed points, while the other one was used at the Ar and Hg fixed points. NMC measured them before and after NIM measured them. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 average reference value using NIM as a link are reported with expanded uncertainties at each measured fixed point.

  12. MCNP and GADRAS Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klasky, Marc Louis; Myers, Steven Charles; James, Michael R.

    To facilitate the timely execution of System Threat Reviews (STRs) for DNDO, and also to develop a methodology for performing STRs, LANL performed comparisons of several radiation transport codes (MCNP, GADRAS, and Gamma-Designer) that have been previously utilized to compute radiation signatures. While each of these codes has strengths, it is of paramount interest to determine the limitations of each of the respective codes and also to identify the most time efficient means by which to produce computational results, given the large number of parametric cases that are anticipated in performing STR's. These comparisons serve to identify regions of applicabilitymore » for each code and provide estimates of uncertainty that may be anticipated. Furthermore, while performing these comparisons, examination of the sensitivity of the results to modeling assumptions was also examined. These investigations serve to enable the creation of the LANL methodology for performing STRs. Given the wide variety of radiation test sources, scenarios, and detectors, LANL calculated comparisons of the following parameters: decay data, multiplicity, device (n,γ) leakages, and radiation transport through representative scenes and shielding. This investigation was performed to understand potential limitations utilizing specific codes for different aspects of the STR challenges.« less

  13. a Performance Comparison of Feature Detectors for Planetary Rover Mapping and Localization

    NASA Astrophysics Data System (ADS)

    Wan, W.; Peng, M.; Xing, Y.; Wang, Y.; Liu, Z.; Di, K.; Teng, B.; Mao, X.; Zhao, Q.; Xin, X.; Jia, M.

    2017-07-01

    Feature detection and matching are key techniques in computer vision and robotics, and have been successfully implemented in many fields. So far there is no performance comparison of feature detectors and matching methods for planetary mapping and rover localization using rover stereo images. In this research, we present a comprehensive evaluation and comparison of six feature detectors, including Moravec, Förstner, Harris, FAST, SIFT and SURF, aiming for optimal implementation of feature-based matching in planetary surface environment. To facilitate quantitative analysis, a series of evaluation criteria, including distribution evenness of matched points, coverage of detected points, and feature matching accuracy, are developed in the research. In order to perform exhaustive evaluation, stereo images, simulated under different baseline, pitch angle, and interval of adjacent rover locations, are taken as experimental data source. The comparison results show that SIFT offers the best overall performance, especially it is less sensitive to changes of image taken at adjacent locations.

  14. Computational Chemistry Comparison and Benchmark Database

    National Institute of Standards and Technology Data Gateway

    SRD 101 NIST Computational Chemistry Comparison and Benchmark Database (Web, free access)   The NIST Computational Chemistry Comparison and Benchmark Database is a collection of experimental and ab initio thermochemical properties for a selected set of molecules. The goals are to provide a benchmark set of molecules for the evaluation of ab initio computational methods and allow the comparison between different ab initio computational methods for the prediction of thermochemical properties.

  15. Testing Multilateral Comparisons in Africa.

    ERIC Educational Resources Information Center

    Bender, M. Lionel

    In this paper, the multilateral comparison method of classifying languages is described and analyzed. It is suggested that while it is espoused as a simple and reasonable approach to language classification, the method has serious flaws. "Multilateral" or "mass" comparison (MC) is not a method of genetic language…

  16. NIST-NRC Comparison of Total Immersion Liquid-in-Glass Thermometers

    NASA Astrophysics Data System (ADS)

    Hill, K. D.; Gee, D. J.; Cross, C. D.; Strouse, G. F.

    2009-02-01

    The use of liquid-in-glass (LIG) thermometers is described in many documentary standards in the fields of environmental testing, material testing, and material transfer. Many national metrology institutes, including the National Institute of Standards and Technology (NIST) and the National Research Council of Canada (NRC), list calibration services for these thermometers among the Calibration Measurement Capabilities of Appendix C of the BIPM Key Comparison Database. NIST and NRC arranged a bilateral comparison of a set of total-immersion ASTM-type LIG thermometers to validate their uncertainty claims. Two each of ASTM thermometer types 62C through 69C were calibrated at NIST and at NRC at four temperatures distributed over the range appropriate to each thermometer, in addition to the ice point. Collectively, the thermometers span a temperature range of - 38 °C to 305 °C. In total, 160 measurements (80 pairs) comprise the comparison data set. Pair-wise differences ( T NIST- T NRC) were formed for each thermometer at each temperature. For 8 of the 80 pairs (10 %), the differences exceed the k = 2 combined uncertainties. These results support the claimed capabilities of NIST and NRC for the calibration of LIG thermometers.

  17. Rankings, Standards, and Competition: Task vs. Scale Comparisons

    ERIC Educational Resources Information Center

    Garcia, Stephen M.; Tor, Avishalom

    2007-01-01

    Research showing how upward social comparison breeds competitive behavior has so far conflated local comparisons in "task" performance (e.g. a test score) with comparisons on a more general "scale" (i.e. an underlying skill). Using a ranking methodology (Garcia, Tor, & Gonzalez, 2006) to separate task and scale comparisons, Studies 1-2 reveal that…

  18. Social comparison in the brain: A coordinate-based meta-analysis of functional brain imaging studies on the downward and upward comparisons.

    PubMed

    Luo, Yi; Eickhoff, Simon B; Hétu, Sébastien; Feng, Chunliang

    2018-01-01

    Social comparison is ubiquitous across human societies with dramatic influence on people's well-being and decision making. Downward comparison (comparing to worse-off others) and upward comparison (comparing to better-off others) constitute two types of social comparisons that produce different neuropsychological consequences. Based on studies exploring neural signatures associated with downward and upward comparisons, the current study utilized a coordinate-based meta-analysis to provide a refinement of understanding about the underlying neural architecture of social comparison. We identified consistent involvement of the ventral striatum and ventromedial prefrontal cortex in downward comparison and consistent involvement of the anterior insula and dorsal anterior cingulate cortex in upward comparison. These findings fit well with the "common-currency" hypothesis that neural representations of social gain or loss resemble those for non-social reward or loss processing. Accordingly, we discussed our findings in the framework of general reinforcement learning (RL) hypothesis, arguing how social gain/loss induced by social comparisons could be encoded by the brain as a domain-general signal (i.e., prediction errors) serving to adjust people's decisions in social settings. Although the RL account may serve as a heuristic framework for the future research, other plausible accounts on the neuropsychological mechanism of social comparison were also acknowledged. Hum Brain Mapp 39:440-458, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. 30 CFR 206.155 - Accounting for comparison.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Accounting for comparison. 206.155 Section 206... MANAGEMENT PRODUCT VALUATION Federal Gas § 206.155 Accounting for comparison. (a) Except as provided in... subpart. (b) The requirement for accounting for comparison contained in the terms of leases will govern as...

  20. Final report on CCT-K6: Comparison of local realisations of dew-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.

    2015-01-01

    A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Quantum Private Comparison Protocol with Linear Optics

    NASA Astrophysics Data System (ADS)

    Luo, Qing-bin; Yang, Guo-wu; She, Kun; Li, Xiaoyu

    2016-12-01

    In this paper, we propose an innovative quantum private comparison(QPC) protocol based on partial Bell-state measurement from the view of linear optics, which enabling two parties to compare the equality of their private information with the help of a semi-honest third party. Partial Bell-state measurement has been realized by using only linear optical elements in experimental measurement-device-independent quantum key distribution(MDI-QKD) schemes, which makes us believe that our protocol can be realized in the near future. The security analysis shows that the participants will not leak their private information.

  2. Final report on EURAMET.QM-S10/1274: supplementary comparison of preparative capabilities for automotive gas mixtures

    NASA Astrophysics Data System (ADS)

    Val'ková, M.; Ďurišová, Z.; Szilágyi, Z. N.; Büki, T.; Fükű, J.

    2016-01-01

    This bilateral supplementary preparative comparison involves standard gas mixtures of automotive gas containing carbon monoxide, carbon dioxide and propane in nitrogen. Two laboratories (SMU, Slovakia and MKEH, Hungary) participated in this supplementary comparison. SMU was the coordinating laboratory, responsible for collecting and reporting measurement results. The participants have established facilities for automotive gas gravimetric preparation and analysis. The agreement of the results in this supplementary comparison is good. All the results with their reported uncertainties are in agreement with the reference values for the participants. SMU participated and obtained good results in the previous preparative comparison organised within EURAMET in this field. Both laboratories have existing claims for their Calibration and Measurement Capabilities (CMCs) for automotive gas mixtures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report of EURAMET 1197: Supplementary bilateral comparison of hydraulic gauge pressure standards up to 50 MPa

    NASA Astrophysics Data System (ADS)

    Durgut, Yasin; Petrovski, Nenad; Kacarski, Vanco

    2012-01-01

    Interlaboratory comparisons are important for the laboratories to assess their own measurement capability. It is equally important for the accreditation bodies and assessors during the audit process of a laboratory to judge whether the laboratory is doing well. As per accreditation rules, it is mandatory for the testing and calibration laboratories to participate in such comparisons from time to time. In this report, results of the bilateral interlaboratory comparison in pressure area in hydraulic media up to 50 MPa gauge between UME (Turkey) and BOM (The FYR of Macedonia) are presented. The artefact used for the comparison was a digital pressure calibrator and its drift was taken into account in the calculation. Results show that all En values lie in acceptable limits. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Geometric facial comparisons in speed-check photographs.

    PubMed

    Buck, Ursula; Naether, Silvio; Kreutz, Kerstin; Thali, Michael

    2011-11-01

    In many cases, it is not possible to call the motorists to account for their considerable excess in speeding, because they deny being the driver on the speed-check photograph. An anthropological comparison of facial features using a photo-to-photo comparison can be very difficult depending on the quality of the photographs. One difficulty of that analysis method is that the comparison photographs of the presumed driver are taken with a different camera or camera lens and from a different angle than for the speed-check photo. To take a comparison photograph with exactly the same camera setup is almost impossible. Therefore, only an imprecise comparison of the individual facial features is possible. The geometry and position of each facial feature, for example the distances between the eyes or the positions of the ears, etc., cannot be taken into consideration. We applied a new method using 3D laser scanning, optical surface digitalization, and photogrammetric calculation of the speed-check photo, which enables a geometric comparison. Thus, the influence of the focal length and the distortion of the objective lens are eliminated and the precise position and the viewing direction of the speed-check camera are calculated. Even in cases of low-quality images or when the face of the driver is partly hidden, good results are delivered using this method. This new method, Geometric Comparison, is evaluated and validated in a prepared study which is described in this article.

  5. Objective comparison of particle tracking methods

    PubMed Central

    Chenouard, Nicolas; Smal, Ihor; de Chaumont, Fabrice; Maška, Martin; Sbalzarini, Ivo F.; Gong, Yuanhao; Cardinale, Janick; Carthel, Craig; Coraluppi, Stefano; Winter, Mark; Cohen, Andrew R.; Godinez, William J.; Rohr, Karl; Kalaidzidis, Yannis; Liang, Liang; Duncan, James; Shen, Hongying; Xu, Yingke; Magnusson, Klas E. G.; Jaldén, Joakim; Blau, Helen M.; Paul-Gilloteaux, Perrine; Roudot, Philippe; Kervrann, Charles; Waharte, François; Tinevez, Jean-Yves; Shorte, Spencer L.; Willemse, Joost; Celler, Katherine; van Wezel, Gilles P.; Dan, Han-Wei; Tsai, Yuh-Show; de Solórzano, Carlos Ortiz; Olivo-Marin, Jean-Christophe; Meijering, Erik

    2014-01-01

    Particle tracking is of key importance for quantitative analysis of intracellular dynamic processes from time-lapse microscopy image data. Since manually detecting and following large numbers of individual particles is not feasible, automated computational methods have been developed for these tasks by many groups. Aiming to perform an objective comparison of methods, we gathered the community and organized, for the first time, an open competition, in which participating teams applied their own methods independently to a commonly defined data set including diverse scenarios. Performance was assessed using commonly defined measures. Although no single method performed best across all scenarios, the results revealed clear differences between the various approaches, leading to important practical conclusions for users and developers. PMID:24441936

  6. Objective comparison of particle tracking methods.

    PubMed

    Chenouard, Nicolas; Smal, Ihor; de Chaumont, Fabrice; Maška, Martin; Sbalzarini, Ivo F; Gong, Yuanhao; Cardinale, Janick; Carthel, Craig; Coraluppi, Stefano; Winter, Mark; Cohen, Andrew R; Godinez, William J; Rohr, Karl; Kalaidzidis, Yannis; Liang, Liang; Duncan, James; Shen, Hongying; Xu, Yingke; Magnusson, Klas E G; Jaldén, Joakim; Blau, Helen M; Paul-Gilloteaux, Perrine; Roudot, Philippe; Kervrann, Charles; Waharte, François; Tinevez, Jean-Yves; Shorte, Spencer L; Willemse, Joost; Celler, Katherine; van Wezel, Gilles P; Dan, Han-Wei; Tsai, Yuh-Show; Ortiz de Solórzano, Carlos; Olivo-Marin, Jean-Christophe; Meijering, Erik

    2014-03-01

    Particle tracking is of key importance for quantitative analysis of intracellular dynamic processes from time-lapse microscopy image data. Because manually detecting and following large numbers of individual particles is not feasible, automated computational methods have been developed for these tasks by many groups. Aiming to perform an objective comparison of methods, we gathered the community and organized an open competition in which participating teams applied their own methods independently to a commonly defined data set including diverse scenarios. Performance was assessed using commonly defined measures. Although no single method performed best across all scenarios, the results revealed clear differences between the various approaches, leading to notable practical conclusions for users and developers.

  7. Comparison promotes learning and transfer of relational categories.

    PubMed

    Kurtz, Kenneth J; Boukrina, Olga; Gentner, Dedre

    2013-07-01

    We investigated the effect of co-presenting training items during supervised classification learning of novel relational categories. Strong evidence exists that comparison induces a structural alignment process that renders common relational structure more salient. We hypothesized that comparisons between exemplars would facilitate learning and transfer of categories that cohere around a common relational property. The effect of comparison was investigated using learning trials that elicited a separate classification response for each item in presentation pairs that could be drawn from the same or different categories. This methodology ensures consideration of both items and invites comparison through an implicit same-different judgment inherent in making the two responses. In a test phase measuring learning and transfer, the comparison group significantly outperformed a control group receiving an equivalent training session of single-item classification learning. Comparison-based learners also outperformed the control group on a test of far transfer, that is, the ability to accurately classify items from a novel domain that was relationally alike, but surface-dissimilar, to the training materials. Theoretical and applied implications of this comparison advantage are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  8. 40 CFR 761.326 - Conducting the comparison study.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Conducting the comparison study. 761...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the comparison study samples using the alternative method. For an alternative extraction method or alternative...

  9. 40 CFR 761.326 - Conducting the comparison study.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Conducting the comparison study. 761...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the comparison study samples using the alternative method. For an alternative extraction method or alternative...

  10. SUPPLEMENTARY COMPARISON COOMET. M.P-S5 of hydraulic gauge pressure standards from 5 MPa to 34 MPa

    NASA Astrophysics Data System (ADS)

    Babayev, E. A.; Klenovská, Simona; Páviš, Richard; Pražák, Dominik

    2018-01-01

    This report describes the results of bilateral inter laboratory comparison (BILC) denoted as COOMET.M.P-S5 (also known as supplementary comparison COOMET 723/AZ/17). The comparison measurements between the two participants, Czech Metrology Institute (CMI) (pilot laboratory) and Azerbaijan İnstitute of Metrology (AzMI), started in April 2017 and finished in June 2017. The transfer standards was a digital manometer, Crystal XP 2i with the gauge pressure range (0–34000) kPa. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report on VMI-NMISA bilateral comparison APMP.T-K3.1: Realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans

    2012-01-01

    The Comité Consulatif de Thermométrie (CCT) has organized several key comparisons to compare realizations of the ITS-90 in different National Metrology Institutes. To keep the organization, time scale and data processing of such a comparison manageable, the number of participants in a CCT key comparison (CCT KC) is limited to a few laboratories in each major economic region. Subsequent regional key comparisons are linked to the applicable CCT KC by two or more linking laboratories. For the temperature range from 83.8058 K (triple point of Ar) to 933.473 K (freezing point of Al), a key comparison, CCT-K3, was carried out from 1997 to 2001 among representative laboratories in North America, Europe and Asia. Following CCT-K3, the Asia-Pacific Metrology Program Key Comparison 3 (APMP.T-K3) was organized for National Metrology Institutes in the Asia/Pacific region. NMIA (Australia) and KRISS (South Korea) provided the link between CCT-K3 and APMP.T-K3. APMP.T-K3, which took place from February 2000 to June 2003, covered the temperature range from -38.8344 °C (triple point of Hg) to 419.527 °C (freezing point of Zn), using a standard platinum resistance thermometer (SPRT) as the artefact. In June 2007 the Vietnam Metrology Institute (VMI) requested a bilateral comparison to link their SPRT calibration capabilities to APMP.T-K3, and in October 2007 the National Metrology Institute of South Africa (NMISA) agreed to provide the link to APMP.T-K3. Like APMP.T-K3, the comparison was restricted to the Hg to Zn temperature range to reduce the chance of drift in the SPRT artefact. The comparison was carried out in a participant-pilot-participant topology (with NMISA as the pilot and VMI as the participant). VMI's results in the comparison were linked to the Average Reference Values of CCT-K3 via NMISA's results in APMP.T-K3. The resistance ratios measured by VMI and NMISA at Zn, Sn, Ga and Hg fixed points agree within their combined uncertainties, and VMI's results also

  12. Differential Item Functioning Detection across Two Methods of Defining Group Comparisons: Pairwise and Composite Group Comparisons

    ERIC Educational Resources Information Center

    Sari, Halil Ibrahim; Huggins, Anne Corinne

    2015-01-01

    This study compares two methods of defining groups for the detection of differential item functioning (DIF): (a) pairwise comparisons and (b) composite group comparisons. We aim to emphasize and empirically support the notion that the choice of pairwise versus composite group definitions in DIF is a reflection of how one defines fairness in DIF…

  13. Final Report: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo

    2015-01-01

    The EURAMET.M.FF-K6 comparison was organized for the purpose of determination of the degree of equivalence of the primary (national) standards for low-pressure gas flow measurement over the range (2 to 100) m3/h and was performed simultaneously with CCM.FF-K6.2011 with the same transfer standard. A rotary gas meter G65 was used as a transfer standard. The measurements were provided by prescribed reference conditions. Fifteen laboratories from EURAMET participated in this key comparison - SMU, Slovakia; PTB, Germany; CEM, Spain; LNE-LADG, France; VSL, Netherlands; CMI, Czech Republic; BEV, Austria; MKEH, Hungary; GUM Poland; SP, Sweden; METAS, Switzerland; DMDM, Serbia; TUBITAK-UME, Turkey; EIM, Greece; IMBiH, Bosnia-Herzegovina. The EURAMET.M.FF-K6 is linked to the CCM.FF-K6.2011 by correcting the results of three linking laboratories (Slovakia SMU, Germany PTB and France LNE LADG). This correction provides an estimate of what would have been the result from the EURAMET.M-FF-K6 participants, if they had actually participated in CCM.FF-K6.2011. According to the evaluation 93.7 % of the results were consistent with KCRV, 3.4 % of the results were in the warning level and 2.9 % of the results were inconsistent. The results of this comparison can be used for review of the CMC tables. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system

    DOE PAGES

    Chumbley, Scott; Zhang, Song; Morris, Max; ...

    2016-11-16

    Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less

  15. Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chumbley, Scott; Zhang, Song; Morris, Max

    Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less

  16. SUPPLEMENTARY COMPARISON: Final report of the bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B between PTB and NIMT

    NASA Astrophysics Data System (ADS)

    Sanponpute, Tassanai; Meesaplak, Apichaya; Herrmann, Konrad; Menelao, Febo

    2009-01-01

    The bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B was arranged by the National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison was to confirm the calibration and measurement capabilities of NIMT in hardness measurement. The period of measurement covered March to August 2009. There were two sets of artefacts: scale A artefact set and scale B artefact set. The scale A artefact set consisted of seven hardness blocks: 35 HRA, 40 HRA, 55 HRA, 60 HRA, 70 HRA, 80 HRA, 85 HRA. The artefact set for scale B consisted of nine hardness blocks: 25 HRB, 30 HRB, 40 HRB, 50 HRB, 60 HRB, 70 HRB, 80 HRB, 90 HRB, 100 HRB. Laboratories had to ensure that the primary Rockwell hardness machines passed the verification process according to ISO 6508-3. Then participants measured the hardness value by making ten indentations in a designated area of each artefact block. Hardness measurement results and uncertainty budget were then reported to the pilot laboratory and were used to compute the degrees of equivalence in terms of the Comparison Reference Value (CRV) and En ratio. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Comparison versus Contrast: Task Specifics Affect Category Acquisition

    ERIC Educational Resources Information Center

    Ankowski, Amber A.; Vlach, Haley A.; Sandhofer, Catherine M.

    2013-01-01

    A large literature has documented that comparison and contrast lead to better performance in a variety of tasks. However, studies of comparison and contrast present contradictory conclusions as to when and how these processes benefit learners. Across four studies, we examined how the specifics of the comparison and contrast task affect performance…

  18. Neuropsychological Comparison of Children with Heavy Prenatal Alcohol Exposure and an IQ-Matched Comparison Group

    PubMed Central

    Vaurio, Linnea; Riley, Edward P.; Mattson, Sarah N.

    2012-01-01

    An objective in current research on children with fetal alcohol spectrum disorders (FASD) is to determine neurobehavioral profiles to identify affected individuals. Deficits observed when children with FASD are compared to typically developing controls may be confounded by lower IQ scores in the subjects with FASD. To determine if prenatal alcohol exposure is associated with neurobehavioral deficits after controlling for IQ differences, multivariate analyses were conducted to compare alcohol-exposed (ALC) subjects to a comparison group closely matched on IQ (IQC). The initial analysis included a broad neuropsychological battery with measures of language, executive function, visual–motor integration, motor ability, and academic achievement. Additional, in depth comparisons focused on visual sustained attention, verbal learning and memory and parent/guardian-reported behavior problems. Group differences (ALC < IQC) were found on verbal learning and parent-rated behavior problems. Group differences were marginally significant (measures within the broad neuropsychological comparison) or not significant (visual attention, retention of verbal material) on the remaining comparisons. Therefore, some deficits (e.g., verbal learning and behavior problems) in children with heavy prenatal alcohol exposure cannot be explained by the lower FSIQ observed in the population. These areas of relative weakness could be useful in distinguishing children with FASD from other children with lowered IQ. PMID:21349236

  19. Quantum key distribution with finite resources: Secret key rates via Renyi entropies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abruzzo, Silvestre; Kampermann, Hermann; Mertz, Markus

    A realistic quantum key distribution (QKD) protocol necessarily deals with finite resources, such as the number of signals exchanged by the two parties. We derive a bound on the secret key rate which is expressed as an optimization problem over Renyi entropies. Under the assumption of collective attacks by an eavesdropper, a computable estimate of our bound for the six-state protocol is provided. This bound leads to improved key rates in comparison to previous results.

  20. Learning in clinical practice: Stimulating and discouraging response to social comparison.

    PubMed

    Raat, Janet; Kuks, Jan; Cohen-Schotanus, Janke

    2010-01-01

    Social comparison theory is relevant for learning in general. In a clinical context, we examined four hypotheses concerning: preferred other to compare with, preferred direction of comparison, response to social comparison and influence of personal social comparison orientation (SCO). To investigate the relevance of social comparison for clinical workplace learning. Students (n = 437) from nine different hospitals completed two questionnaires measuring their SCO and the direction of and response to their comparisons. t-tests were used to analyse the data. Students substantially did compare. They preferred to compare with peer students more than with residents or staff, and with peers doing better more than with peers doing worse. Their response to social comparison was more often stimulating for learning than discouraging. Students high in SCO reported a stronger stimulating and discouraging response to their comparisons than students low in SCO. Social comparison does play a role in clinical workplace learning. The mainly stimulating response to social comparison indicates a positive learning influence. The preferred comparison with peers emphasizes the role of peers in the learning process. Further research should focus on student comparison behaviour and on situations that strengthen the positive effects of social comparison and reduce the negative or obstructing ones.

  1. Symbolic comparisons of objects on color attributes.

    PubMed

    Paivio, A; te Linde, J

    1980-11-01

    Symbolic comparisons of object brightness and color were investigated in two experiments using words and outline drawings as stimuli. Both experiments yielded orderly symbolic distance effects. Contrary to prediction, no reliable picture advantages emerged. For color comparison, individual differences in word fluency and color memory predicted decision time with word stimuli. These results contrast sharply with those of previous comparison studies involving concrete dimensions. The results are discussed in terms of dual-coding theory and the role of verbal mechanisms in memory for object color.

  2. Multiple alignment-free sequence comparison

    PubMed Central

    Ren, Jie; Song, Kai; Sun, Fengzhu; Deng, Minghua; Reinert, Gesine

    2013-01-01

    Motivation: Recently, a range of new statistics have become available for the alignment-free comparison of two sequences based on k-tuple word content. Here, we extend these statistics to the simultaneous comparison of more than two sequences. Our suite of statistics contains, first, and , extensions of statistics for pairwise comparison of the joint k-tuple content of all the sequences, and second, , and , averages of sums of pairwise comparison statistics. The two tasks we consider are, first, to identify sequences that are similar to a set of target sequences, and, second, to measure the similarity within a set of sequences. Results: Our investigation uses both simulated data as well as cis-regulatory module data where the task is to identify cis-regulatory modules with similar transcription factor binding sites. We find that although for real data, all of our statistics show a similar performance, on simulated data the Shepp-type statistics are in some instances outperformed by star-type statistics. The multiple alignment-free statistics are more sensitive to contamination in the data than the pairwise average statistics. Availability: Our implementation of the five statistics is available as R package named ‘multiAlignFree’ at be http://www-rcf.usc.edu/∼fsun/Programs/multiAlignFree/multiAlignFreemain.html. Contact: reinert@stats.ox.ac.uk Supplementary information: Supplementary data are available at Bioinformatics online. PMID:23990418

  3. Automated UMLS-Based Comparison of Medical Forms

    PubMed Central

    Dugas, Martin; Fritz, Fleur; Krumm, Rainer; Breil, Bernhard

    2013-01-01

    Medical forms are very heterogeneous: on a European scale there are thousands of data items in several hundred different systems. To enable data exchange for clinical care and research purposes there is a need to develop interoperable documentation systems with harmonized forms for data capture. A prerequisite in this harmonization process is comparison of forms. So far – to our knowledge – an automated method for comparison of medical forms is not available. A form contains a list of data items with corresponding medical concepts. An automatic comparison needs data types, item names and especially item with these unique concept codes from medical terminologies. The scope of the proposed method is a comparison of these items by comparing their concept codes (coded in UMLS). Each data item is represented by item name, concept code and value domain. Two items are called identical, if item name, concept code and value domain are the same. Two items are called matching, if only concept code and value domain are the same. Two items are called similar, if their concept codes are the same, but the value domains are different. Based on these definitions an open-source implementation for automated comparison of medical forms in ODM format with UMLS-based semantic annotations was developed. It is available as package compareODM from http://cran.r-project.org. To evaluate this method, it was applied to a set of 7 real medical forms with 285 data items from a large public ODM repository with forms for different medical purposes (research, quality management, routine care). Comparison results were visualized with grid images and dendrograms. Automated comparison of semantically annotated medical forms is feasible. Dendrograms allow a view on clustered similar forms. The approach is scalable for a large set of real medical forms. PMID:23861827

  4. Final report on SIM.T-S5: comparison of the calibration of 100 Ω platinum resistance thermometers

    NASA Astrophysics Data System (ADS)

    del Campo, D.; García, S.; Velasquez, A.; Medrano, J. A.; Solano, A.; Torres, H. E.

    2015-01-01

    An International Comparison on industrial Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Panama, Honduras, El Salvador, Costa Rica and Nicaragua began in 2013 and was successfully completed in 2014. Two PRTs were circulated (hand carried) and compared in the range from -38.8 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, acted as the pilot laboratory providing the reference value of the comparison. The thermometers have shown an acceptable behavior throughout the comparison, therefore the results can be considered valid for comparing the measurement capabilities of the participant laboratories. The equivalence between the participant laboratories in the calibration of platinum resistance thermometers by comparison in the range from -38,8 °C up to 250 °C has been demonstrated in almost all cases. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Indirect Comparisons: A Review of Reporting and Methodological Quality

    PubMed Central

    Donegan, Sarah; Williamson, Paula; Gamble, Carrol; Tudur-Smith, Catrin

    2010-01-01

    Background The indirect comparison of two interventions can be valuable in many situations. However, the quality of an indirect comparison will depend on several factors including the chosen methodology and validity of underlying assumptions. Published indirect comparisons are increasingly more common in the medical literature, but as yet, there are no published recommendations of how they should be reported. Our aim is to systematically review the quality of published indirect comparisons to add to existing empirical data suggesting that improvements can be made when reporting and applying indirect comparisons. Methodology/Findings Reviews applying statistical methods to indirectly compare the clinical effectiveness of two interventions using randomised controlled trials were eligible. We searched (1966–2008) Database of Abstracts and Reviews of Effects, The Cochrane library, and Medline. Full review publications were assessed for eligibility. Specific criteria to assess quality were developed and applied. Forty-three reviews were included. Adequate methodology was used to calculate the indirect comparison in 41 reviews. Nineteen reviews assessed the similarity assumption using sensitivity analysis, subgroup analysis, or meta-regression. Eleven reviews compared trial-level characteristics. Twenty-four reviews assessed statistical homogeneity. Twelve reviews investigated causes of heterogeneity. Seventeen reviews included direct and indirect evidence for the same comparison; six reviews assessed consistency. One review combined both evidence types. Twenty-five reviews urged caution in interpretation of results, and 24 reviews indicated when results were from indirect evidence by stating this term with the result. Conclusions This review shows that the underlying assumptions are not routinely explored or reported when undertaking indirect comparisons. We recommend, therefore, that the quality of indirect comparisons should be improved, in particular, by assessing

  6. Longitudinal meta-analysis of NIST pH Standard Reference Materials(®): a complement to pH key comparisons.

    PubMed

    Pratt, Kenneth W

    2015-04-01

    This meta-analysis assesses the long-term (up to 70 years) within-laboratory variation of the NIST pH Standard Reference Material® (SRM) tetroxalate, phthalate, phosphate, borate, and carbonate buffers. Values of ΔpH(S), the difference between the certified pH value, pH(S), of each SRM issue and the mean of all pH(S) values for the given SRM at that Celsius temperature, t, are graphed as a function of the SRM issue and t. In most cases, |ΔpH(S)| < 0.004. Deviations from the nominal base:acid amount (mole) ratio of a buffer yield t-independent, constant shifts in ΔpH(S). The mean ΔpH(S) characterizes such deviations. The corresponding mole fraction of impurity in the conjugate buffer component is generally <0.3 %. Changes in the equipment, personnel, materials, and methodology of the pH(S) measurement yield t-dependent variations. The standard deviation of ΔpH(S) characterizes such changes. Standard deviations of ΔpH(S) are generally 0.0015 or less. The results provide a long-term, single-institution complement to the time-specific, multi-institution results of pH key comparisons administered by the Consultative Committee for Metrology in Chemistry and Biology (CCQM).

  7. Longitudinal relationships among internalization of the media ideal, peer social comparison, and body dissatisfaction: implications for the tripartite influence model.

    PubMed

    Rodgers, Rachel F; McLean, Siân A; Paxton, Susan J

    2015-05-01

    Sociocultural theory of body dissatisfaction posits that internalization of the media ideal and appearance comparison are predictors of body dissatisfaction, a key risk factor for eating disorders. However, no data exist regarding the longitudinal relationships between these variables. The aim of this study was to explore longitudinal relationships among internalization of the media-ideal, social appearance comparison, and body dissatisfaction. A sample of 277 Grade 7 school girls (M age = 12.77 years, SD = 0.44) completed measures of internalization of the media ideal, social appearance comparison, and body dissatisfaction at baseline, 8 months, and 14 months. Path analyses indicated that baseline internalization of the media ideal predicted social appearance comparison and body dissatisfaction at 8 months, and social appearance comparison at 8 months predicted body dissatisfaction at 14 months. A reciprocal effect emerged with body dissatisfaction at 8 months predicting internalization of the media ideal at 14 months. The findings inform sociocultural theory of body dissatisfaction, suggesting that internalization of the media ideal precedes and predicts appearance comparison and that body image interventions that target internalization of the media ideal, and social appearance comparison as well as body dissatisfaction are likely to be effective. (c) 2015 APA, all rights reserved).

  8. Methodological problems in the use of indirect comparisons for evaluating healthcare interventions: survey of published systematic reviews.

    PubMed

    Song, Fujian; Loke, Yoon K; Walsh, Tanya; Glenny, Anne-Marie; Eastwood, Alison J; Altman, Douglas G

    2009-04-03

    To investigate basic assumptions and other methodological problems in the application of indirect comparison in systematic reviews of competing healthcare interventions. Survey of published systematic reviews. Inclusion criteria Systematic reviews published between 2000 and 2007 in which an indirect approach had been explicitly used. Identified reviews were assessed for comprehensiveness of the literature search, method for indirect comparison, and whether assumptions about similarity and consistency were explicitly mentioned. The survey included 88 review reports. In 13 reviews, indirect comparison was informal. Results from different trials were naively compared without using a common control in six reviews. Adjusted indirect comparison was usually done using classic frequentist methods (n=49) or more complex methods (n=18). The key assumption of trial similarity was explicitly mentioned in only 40 of the 88 reviews. The consistency assumption was not explicit in most cases where direct and indirect evidence were compared or combined (18/30). Evidence from head to head comparison trials was not systematically searched for or not included in nine cases. Identified methodological problems were an unclear understanding of underlying assumptions, inappropriate search and selection of relevant trials, use of inappropriate or flawed methods, lack of objective and validated methods to assess or improve trial similarity, and inadequate comparison or inappropriate combination of direct and indirect evidence. Adequate understanding of basic assumptions underlying indirect and mixed treatment comparison is crucial to resolve these methodological problems. APPENDIX 1: PubMed search strategy. APPENDIX 2: Characteristics of identified reports. APPENDIX 3: Identified studies. References of included studies.

  9. Comparison of GLONASS and GPS Time Transfers

    NASA Astrophysics Data System (ADS)

    Daly, P.; Koshelyaevsky, N. B.; Lewandowski, W.; Petit, G.; Thomas, C.

    1993-01-01

    The Russian global space navigation system GLONASS could provide a technique similar to GPS for international time comparison. The main limitation to its use for time transfer is the lack of commercially available time receivers. The University of Leeds built a GPS/GLONASS receiver five years ago and since then has provided continuous information about GLONASS time and its comparison with GPS time. For the last two years the VNIIFTRI and several other Russian time laboratories have used Russian-built GLONASS navigation receivers for time comparisons. Since June 1991, the VNIIFTRI has operated a GPS time receiver which offers, for the first time, an opportunity for the direct comparison of time transfers using GPS and GLONASS. This seven-month experiment shows that even with relatively imprecise data recording and processing, in terms of time metrology, GLONASS can provide continental time transfer at a level of several tens of nanoseconds.

  10. Transfer Standard Uncertainty Can Cause Inconclusive Inter-Laboratory Comparisons

    PubMed Central

    Wright, John; Toman, Blaza; Mickan, Bodo; Wübbeler, Gerd; Bodnar, Olha; Elster, Clemens

    2016-01-01

    Inter-laboratory comparisons use the best available transfer standards to check the participants’ uncertainty analyses, identify underestimated uncertainty claims or unknown measurement biases, and improve the global measurement system. For some measurands, instability of the transfer standard can lead to an inconclusive comparison result. If the transfer standard uncertainty is large relative to a participating laboratory’s uncertainty, the commonly used standardized degree of equivalence ≤ 1 criterion does not always correctly assess whether a participant is working within their uncertainty claims. We show comparison results that demonstrate this issue and propose several criteria for assessing a comparison result as passing, failing, or inconclusive. We investigate the behavior of the standardized degree of equivalence and alternative comparison measures for a range of values of the transfer standard uncertainty relative to the individual laboratory uncertainty values. The proposed alternative criteria successfully discerned between passing, failing, and inconclusive comparison results for the cases we examined. PMID:28090123

  11. Identification of divergent protein domains by combining HMM-HMM comparisons and co-occurrence detection.

    PubMed

    Ghouila, Amel; Florent, Isabelle; Guerfali, Fatma Zahra; Terrapon, Nicolas; Laouini, Dhafer; Yahia, Sadok Ben; Gascuel, Olivier; Bréhélin, Laurent

    2014-01-01

    Identification of protein domains is a key step for understanding protein function. Hidden Markov Models (HMMs) have proved to be a powerful tool for this task. The Pfam database notably provides a large collection of HMMs which are widely used for the annotation of proteins in sequenced organisms. This is done via sequence/HMM comparisons. However, this approach may lack sensitivity when searching for domains in divergent species. Recently, methods for HMM/HMM comparisons have been proposed and proved to be more sensitive than sequence/HMM approaches in certain cases. However, these approaches are usually not used for protein domain discovery at a genome scale, and the benefit that could be expected from their utilization for this problem has not been investigated. Using proteins of P. falciparum and L. major as examples, we investigate the extent to which HMM/HMM comparisons can identify new domain occurrences not already identified by sequence/HMM approaches. We show that although HMM/HMM comparisons are much more sensitive than sequence/HMM comparisons, they are not sufficiently accurate to be used as a standalone complement of sequence/HMM approaches at the genome scale. Hence, we propose to use domain co-occurrence--the general domain tendency to preferentially appear along with some favorite domains in the proteins--to improve the accuracy of the approach. We show that the combination of HMM/HMM comparisons and co-occurrence domain detection boosts protein annotations. At an estimated False Discovery Rate of 5%, it revealed 901 and 1098 new domains in Plasmodium and Leishmania proteins, respectively. Manual inspection of part of these predictions shows that it contains several domain families that were missing in the two organisms. All new domain occurrences have been integrated in the EuPathDomains database, along with the GO annotations that can be deduced.

  12. Identification of Divergent Protein Domains by Combining HMM-HMM Comparisons and Co-Occurrence Detection

    PubMed Central

    Ghouila, Amel; Florent, Isabelle; Guerfali, Fatma Zahra; Terrapon, Nicolas; Laouini, Dhafer; Yahia, Sadok Ben; Gascuel, Olivier; Bréhélin, Laurent

    2014-01-01

    Identification of protein domains is a key step for understanding protein function. Hidden Markov Models (HMMs) have proved to be a powerful tool for this task. The Pfam database notably provides a large collection of HMMs which are widely used for the annotation of proteins in sequenced organisms. This is done via sequence/HMM comparisons. However, this approach may lack sensitivity when searching for domains in divergent species. Recently, methods for HMM/HMM comparisons have been proposed and proved to be more sensitive than sequence/HMM approaches in certain cases. However, these approaches are usually not used for protein domain discovery at a genome scale, and the benefit that could be expected from their utilization for this problem has not been investigated. Using proteins of P. falciparum and L. major as examples, we investigate the extent to which HMM/HMM comparisons can identify new domain occurrences not already identified by sequence/HMM approaches. We show that although HMM/HMM comparisons are much more sensitive than sequence/HMM comparisons, they are not sufficiently accurate to be used as a standalone complement of sequence/HMM approaches at the genome scale. Hence, we propose to use domain co-occurrence — the general domain tendency to preferentially appear along with some favorite domains in the proteins — to improve the accuracy of the approach. We show that the combination of HMM/HMM comparisons and co-occurrence domain detection boosts protein annotations. At an estimated False Discovery Rate of 5%, it revealed 901 and 1098 new domains in Plasmodium and Leishmania proteins, respectively. Manual inspection of part of these predictions shows that it contains several domain families that were missing in the two organisms. All new domain occurrences have been integrated in the EuPathDomains database, along with the GO annotations that can be deduced. PMID:24901648

  13. Immediacy bias in social-emotional comparisons.

    PubMed

    White, Katherine; Van Boven, Leaf

    2012-08-01

    In seven studies of naturally occurring, "real-world" emotional events, people demonstrated an immediacy bias in social-emotional comparisons, perceiving their own current or recent emotional reactions as more intense compared with others' emotional reactions to the same events. The events examined include crossing a scary bridge (study 1a), a national tragedy (study 1b), terrorist attacks (studies 2a and 3b), a natural disaster (study 2b), and a presidential election (study 3b). These perceived differences between one's own and others' emotions declined over time, as relatively immediate and recent emotions subsided, a pattern that people were not intuitively aware of (study 2c). This immediacy bias in social-emotional comparisons emerged for both explicit comparisons (studies 1a, 1b, and 3b), and for absolute judgments of emotional intensity (studies 2a, 2b, and 3a). Finally, the immediacy bias in social-emotional comparisons was reduced when people were reminded that emotional display norms might lead others' appearances to understate emotional intensity (studies 3a and 3b). Implications of these findings for social-emotional phenomena are discussed.

  14. The neural correlates of internal and external comparisons: an fMRI study.

    PubMed

    Wen, Xue; Xiang, Yanhui; Cant, Jonathan S; Wang, Tingting; Cupchik, Gerald; Huang, Ruiwang; Mo, Lei

    2017-01-01

    Many previous studies have suggested that various comparisons rely on the same cognitive and neural mechanisms. However, little attention has been paid to exploring the commonalities and differences between the internal comparison based on concepts or rules and the external comparison based on perception. In the present experiment, moral beauty comparison and facial beauty comparison were selected as the representatives of internal comparison and external comparison, respectively. Functional magnetic resonance imaging (fMRI) was used to record brain activity while participants compared the level of moral beauty of two scene drawings containing moral acts or the level of facial beauty of two face photos. In addition, a physical size comparison task with the same stimuli as the beauty comparison was included. We observed that both the internal moral beauty comparison and external facial beauty comparison obeyed a typical distance effect and this behavioral effect recruited a common frontoparietal network involved in comparisons of simple physical magnitudes such as size. In addition, compared to external facial beauty comparison, internal moral beauty comparison induced greater activity in more advanced and complex cortical regions, such as the bilateral middle temporal gyrus and middle occipital gyrus, but weaker activity in the putamen, a subcortical region. Our results provide novel neural evidence for the comparative process and suggest that different comparisons may rely on both common cognitive processes as well as distinct and specific cognitive components.

  15. A scoping review of indirect comparison methods and applications using individual patient data.

    PubMed

    Veroniki, Areti Angeliki; Straus, Sharon E; Soobiah, Charlene; Elliott, Meghan J; Tricco, Andrea C

    2016-04-27

    to estimate effects as if they had come from the same, randomized, population. Key methodological and reporting elements (e.g., evaluation of consistency, existence of study protocol) were often missing from an indirect comparison paper.

  16. ACIX: Atmospheric Correction Inter-comparison Exercise

    NASA Astrophysics Data System (ADS)

    Doxani, Georgia; Gascon, Ferran; Vermote, Éric; Roger, Jean-Claude

    2017-04-01

    The free and open data access policy to Sentinel-2 (S-2) and Landsat-8 (L-8) satellite imagery has stimulated the development of atmospheric correction (AC) processors for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for S-2 and L-8 missions. To this end, the European Space Agency (ESA) and NASA are organizing an exercise on AC processors inter-comparison. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 13 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. A protocol describing the inter-comparison process and the test dataset, which is based on the AERONET sites, will be presented. The protocol has been defined according to what was agreed among the participants during the 1st ACIX workshop held in June 2016. It includes the comparison of aerosol optical thickness and water vapour products of the processors with the AERONET measurements. Moreover, concerning the surface reflectances, the protocol describes the inter-comparison among the processors, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison outcomes will be presented and discussed among the participants in the 2nd ACIX workshop, which will be held on 11-12 April 2017 (ESRIN/ESA). The proposed presentation is an opportunity for the user community to be informed for the first time about the ACIX results and conclusions.

  17. Supplement to photographic catalog of selected planetary size comparisons

    NASA Technical Reports Server (NTRS)

    Meszaros, Stephen Paul

    1991-01-01

    This document updates and extends the photographic catalog of selected planetary size comparisons. It utilizes photographs taken by NASA spacecraft to illustrate size comparisons of planets and moons of the solar system. Global views are depicted at the same scale, within each comparison, allowing size relationships to be studied visually.

  18. Student distress in clinical workplace learning: differences in social comparison behaviours.

    PubMed

    Janet Raat, A N; Schönrock-Adema, Johanna; van Hell, E Ally; Kuks, Jan B M; Cohen-Schotanus, Janke

    2015-03-01

    In medical education, student distress is known to hamper learning and professional development. To address this problem, recent studies aimed at helping students cope with stressful situations. Undergraduate students in clinical practice frequently use experiences of surrounding peers to estimate their abilities to master such challenging situations. This use of the experiences of others, known as social comparison, may affect student distress both positively and negatively. To find characteristics of a beneficial use of social comparison, we examined differences in comparison behaviours between students expressing low and high levels of distress. The participants in our study, response rate 93% (N = 301/321), were all medical students in their first year in clinical practice. They completed the General Health Questionnaire (GHQ-12) to measure distress, and three separate questionnaires to measure: (1) orientation to comparison, (2) motive for comparison, and (3) interpretation of comparison. Differences were analysed using multivariate analysis of variance. Although all students were oriented towards social comparison, the analyses showed that this orientation was less apparent among low-distress students. Besides, the low-distress students were less inclined to use motives indicative for comparisons with peers perceived as performing worse and were less negative in the interpretations of their comparisons. As social comparison is frequently used among all students, we recommend to make them aware of their comparison behaviours and inform them about the pros and cons of the distinguished aspects of the comparison process.

  19. Cache-Cache Comparison for Supporting Meaningful Learning

    ERIC Educational Resources Information Center

    Wang, Jingyun; Fujino, Seiji

    2015-01-01

    The paper presents a meaningful discovery learning environment called "cache-cache comparison" for a personalized learning support system. The processing of seeking hidden relations or concepts in "cache-cache comparison" is intended to encourage learners to actively locate new knowledge in their knowledge framework and check…

  20. 30 CFR 1206.155 - Accounting for comparison.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Accounting for comparison. 1206.155 Section 1206.155 Mineral Resources OFFICE OF NATURAL RESOURCES REVENUE, DEPARTMENT OF THE INTERIOR NATURAL RESOURCES REVENUE PRODUCT VALUATION Federal Gas § 1206.155 Accounting for comparison. (a) Except as provided...

  1. 30 CFR 1206.155 - Accounting for comparison.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Accounting for comparison. 1206.155 Section 1206.155 Mineral Resources OFFICE OF NATURAL RESOURCES REVENUE, DEPARTMENT OF THE INTERIOR NATURAL RESOURCES REVENUE PRODUCT VALUATION Federal Gas § 1206.155 Accounting for comparison. (a) Except as provided...

  2. 30 CFR 1206.155 - Accounting for comparison.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Accounting for comparison. 1206.155 Section 1206.155 Mineral Resources OFFICE OF NATURAL RESOURCES REVENUE, DEPARTMENT OF THE INTERIOR NATURAL RESOURCES REVENUE PRODUCT VALUATION Federal Gas § 1206.155 Accounting for comparison. (a) Except as provided...

  3. Experimental Implementation of a Quantum Optical State Comparison Amplifier

    NASA Astrophysics Data System (ADS)

    Donaldson, Ross J.; Collins, Robert J.; Eleftheriadou, Electra; Barnett, Stephen M.; Jeffers, John; Buller, Gerald S.

    2015-03-01

    We present an experimental demonstration of a practical nondeterministic quantum optical amplification scheme that employs two mature technologies, state comparison and photon subtraction, to achieve amplification of known sets of coherent states with high fidelity. The amplifier uses coherent states as a resource rather than single photons, which allows for a relatively simple light source, such as a diode laser, providing an increased rate of amplification. The amplifier is not restricted to low amplitude states. With respect to the two key parameters, fidelity and the amplified state production rate, we demonstrate significant improvements over previous experimental implementations, without the requirement of complex photonic components. Such a system may form the basis of trusted quantum repeaters in nonentanglement-based quantum communications systems with known phase alphabets, such as quantum key distribution or quantum digital signatures.

  4. Public opinion: Country comparisons

    NASA Astrophysics Data System (ADS)

    Hopkins, Debbie

    2015-11-01

    Climate change awareness, risk perception and policy support vary between and within countries. National-scale comparisons can help to explain this variability and be used to develop targeted interventions.

  5. Overview of Recent Radiation Transport Code Comparisons for Space Applications

    NASA Astrophysics Data System (ADS)

    Townsend, Lawrence

    Recent advances in radiation transport code development for space applications have resulted in various comparisons of code predictions for a variety of scenarios and codes. Comparisons among both Monte Carlo and deterministic codes have been made and published by vari-ous groups and collaborations, including comparisons involving, but not limited to HZETRN, HETC-HEDS, FLUKA, GEANT, PHITS, and MCNPX. In this work, an overview of recent code prediction inter-comparisons, including comparisons to available experimental data, is presented and discussed, with emphases on those areas of agreement and disagreement among the various code predictions and published data.

  6. 16 CFR 233.5 - Miscellaneous price comparisons.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Miscellaneous price comparisons. 233.5... DECEPTIVE PRICING § 233.5 Miscellaneous price comparisons. The practices covered in the provisions set forth... principles. For example, retailers should not advertise a retail price as a “wholesale” price. They should...

  7. Bilateral comparison on electric field measurements between TÜBİTAK UME and SASO NMCC

    NASA Astrophysics Data System (ADS)

    Aslan, Çağlar; Alrobaish, Abdullah M.; Şen, Osman

    2017-01-01

    Electromagnetic (EM) probes are widely utilized in the measurement of EM fields for non-ionizing radiation, electromagnetic compatibility (EMC) testing and other applications in the frequency range 5 Hz-60 GHz. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as IEEE 1309. The existing NMIs or emerging NMIs should refer to the international comparison measurements in order to assure the quality of their measurement results. Therefore, the electric field comparison measurements organized by TUBITAK UME were performed between TUBITAK UME and SASO NMCC at the 100 Hz, 1 kHz, 10 MHz, 100 MHz, 1 GHz, 10 GHz and 18 GHz frequencies in order to obtain the correction factors of the electric field probes. The comparison measurements were carried out in accordance with the Technical Protocol prepared by TUBITAK UME. The measurements started in October 2017 and were completed in January 2017. There was good agreement found for the correction factors. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on the regional supplementary comparison APMP.AUV.A-S1

    NASA Astrophysics Data System (ADS)

    Plangsangmas, Virat; Leeudomwong, Surat; Scott, Andrew; Zhong, Bo; Huang, Yuchung

    2014-01-01

    A regional supplementary comparison APMP.AUV.A-S1 has been carried out for the measurement of sound pressure level, frequency and total distortion of a multi-frequency sound calibrator. The role of the Pilot laboratory was undertaken by the National Institute of Metrology (Thailand) (NIMT). The multi-frequency sound calibrator was circulated through thirteen National Metrology Institutes (NMIs). Two NMIs were added to the original time schedule after starting the circulation. The measurements took place between September 2008 and July 2010. This report includes the measurement results from all the participants. Supplementary Comparison Reference Values (SCRVs) have been determined from the results. Deviations from the SCRVs are mostly within declared expanded uncertainties. It has been found that a term for the inherent instability in this type of device needs to be included in any uncertainty budget, and a recommended minimum value of this has been given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Evaluation of alanine as a reference dosimeter for therapy level dose comparisons in megavoltage electron beams

    NASA Astrophysics Data System (ADS)

    McEwen, Malcolm; Sharpe, Peter; Vörös, Sándor

    2015-04-01

    When comparing absorbed dose standards from different laboratories (e.g. National Measurement Institutes, NMIs, for Key or Supplementary comparisons) it is rarely possible to carry out a direct comparison of primary standard instruments, and therefore some form of transfer detector is required. Historically, air-filled, unsealed ionization chambers have been used because of the long history of using these instruments, very good stability over many years, and ease of transport. However, the use of ion chambers for therapy-level comparisons is not without its problems. Findings from recent investigations suggest that ion chambers are prone to non-random variations, they are not completely robust to standard courier practices, and failure at any step in a comparison can render all measurements potentially useless. An alternative approach is to identify a transfer system that is insensitive to some of these concerns—effectively a dosimeter that is inexpensive, simple to use, robust, but with sufficient precision and of a size relevant to the disseminated quantity in question. The alanine dosimetry system has been successfully used in a number of situations as an audit dosimeter and therefore the purpose of this investigation was to determine whether alanine could also be used as the transfer detector for dosimetric comparisons, which require a lower value for the measurement uncertainty. A measurement protocol was developed for comparing primary standards of absorbed dose to water in high-energy electron beams using alanine pellets irradiated in a water-equivalent plastic phantom. A trial comparison has been carried out between three NMIs and has indicated that alanine is a suitable alternative to ion chambers, with the system used achieving a precision of 0.1%. Although the focus of the evaluation was on the performance of the dosimeter, the comparison results are encouraging, showing agreement at the level of the combined uncertainties (~0.6%). Based on this

  10. EURAMET.M.P-S9: comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Saxholm, S.; Otal, P.; AltintaS, A.; Bermanec, L. G.; Durgut, Y.; Hanrahan, R.; Kocas, I.; Lefkopoulos, A.; Pražák, D.; Sandu, I.; Åetina, J.; Spohr, I.; Steindl, D.; Tammik, K.; Testa, N.

    2016-01-01

    registered as EURAMET project no. 1170 and as a supplementary comparison EURAMET.M.P-S9 in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. AC Power at Power Frequencies: Bilateral comparison between SASO NMCC and TÜBİTAK UME

    NASA Astrophysics Data System (ADS)

    Çaycı, Hüseyin; Yılmaz, Özlem; AlRobaish, Abdullah M.; AlAnazi, Shafi S.; AlAyali, Ahmed R.; AlRumie, Rashed A.

    2018-01-01

    A supplementary bilateral comparison measurement on AC Power at 50/60 Hz between SASO NMCC (GULFMET) and TÜBİTAK UME (EURAMET) was performed with the primary power standards of each partner. Measurement methods and setups which are very similar of the participants, measurement results, calculation of differences in the results, evaluation of uncertainties are given within this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. 16 CFR 233.1 - Former price comparisons.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Former price comparisons. 233.1 Section 233... DECEPTIVE PRICING § 233.1 Former price comparisons. (a) One of the most commonly used forms of bargain advertising is to offer a reduction from the advertiser's own former price for an article. If the former price...

  13. An Analysis of Comparison Questions in the Context of Auditing.

    ERIC Educational Resources Information Center

    Lauer, Thomas W.; Peacock, Eileen

    1990-01-01

    Provides a definition of comparison questions and shows how they relate to the semantic categories of two taxonomies for classifying questions, both of which omit comparison questions. Examines the comparison questions that auditors generate when they diagnose problems in a company. (SR)

  14. Atmospheric Correction Inter-comparison Exercise (ACIX)

    NASA Astrophysics Data System (ADS)

    Vermote, E.; Doxani, G.; Gascon, F.; Roger, J. C.; Skakun, S.

    2017-12-01

    The free and open data access policy to Landsat-8 (L-8) and Sentinel-2 (S-2) satellite imagery has encouraged the development of atmospheric correction (AC) approaches for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for L-8 and S-2 missions. To this end, the European Space Agency (ESA) and National Aeronautics and Space Administration (NASA) have initiated an exercise on the inter-comparison of the available AC processors. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 11 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. All the processors should be operational without requiring parametrization when applied on different areas. A protocol describing in details the inter-comparison metrics and the test dataset based on the AERONET sites has been agreed unanimously during the 1st ACIX workshop in June 2016. In particular, a basic and an advanced run of each of the processor were requested in the frame of ACIX, with the aim to draw robust and reliable conclusions on the processors' performance. The protocol also describes the comparison metrics of the aerosol optical thickness and water vapour products of the processors with the corresponding AERONET measurements. Moreover, concerning the surface reflectances, the inter-comparison among the processors is defined, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison

  15. Final report on comparison of hydraulic pressure balance effective area determination in the range up to 80 MPa

    NASA Astrophysics Data System (ADS)

    Grgec Bermanec, L.; Pantic, D.; Ramac, B.

    2018-01-01

    Bilateral comparison was organized between the laboratory for process measurement of the Croatian Metrology Institute (HMI/FSB-LPM) and the pressure laboratory of the Directorate of Measures and Precious Metals of the Republic of Serbia (DMDM). Laboratory for process measurement of HMI acted as the pilot laboratory. The aim of the comparison was to evaluate the degree of equivalence in the determination of effective area and elastic distortion coefficient, considering respective uncertainties of the two laboratories. Measurements were done on the pressure balance in gauge mode, with oil as transmitting medium, in the gauge pressure range 10–80 MPa. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Comparison of SAND-II and FERRET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wootan, D.W.; Schmittroth, F.

    1981-01-01

    A comparison was made of the advantages and disadvantages of two codes, SAND-II and FERRET, for determining the neutron flux spectrum and uncertainty from experimental dosimeter measurements as anticipated in the FFTF Reactor Characterization Program. This comparison involved an examination of the methodology and the operational performance of each code. The merits of each code were identified with respect to theoretical basis, directness of method, solution uniqueness, subjective influences, and sensitivity to various input parameters.

  17. Target Scattering Metrics: Model-Model and Model-Data Comparisons

    DTIC Science & Technology

    2017-12-13

    measured synthetic aperture sonar (SAS) data or from numerical models is investigated. Metrics are needed for quantitative comparisons for signals...candidate metrics for model-model comparisons are examined here with a goal to consider raw data prior to its reduction to data products, which may...be suitable for input to classification schemes. The investigated metrics are then applied to model-data comparisons. INTRODUCTION Metrics for

  18. Target Scattering Metrics: Model-Model and Model Data comparisons

    DTIC Science & Technology

    2017-12-13

    measured synthetic aperture sonar (SAS) data or from numerical models is investigated. Metrics are needed for quantitative comparisons for signals...candidate metrics for model-model comparisons are examined here with a goal to consider raw data prior to its reduction to data products, which may...be suitable for input to classification schemes. The investigated metrics are then applied to model-data comparisons. INTRODUCTION Metrics for

  19. International comparison CCQM-K84—carbon monoxide in synthetic air at ambient level

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Moon, Dongmin; Lee, Jinbok; Lim, Jeongsik; Hall, Brad; Novelli, Paul; Brewer, Paul J.; Miller, Michael; Murugun, Arul; Doval Minarro, Marta; Qiao, Han; Shuguo, Hu; Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Pankratov, V. V.; Wasserman, I. I.; Zav'yalov, S. V.; Efremova, O. V.; Pavlov, M. V.; Mitchell, Gerald; Guenther, Frank; Walden, Jari; Aoki, Nobuyuki; Shimosaka, Takuya; Tatiana, Mace; Lagler, F.; Borowiak, Annette

    2017-01-01

    Carbon monoxide (CO) is reported to mainly be emitted from industries, transportation, and burnings for various usages. Its atmospheric lifetime varies from weeks to months, depending on the mixing ratio of the highly reactive hydroxyl radical. Even though the ambient level of CO varies as a function of regional sources, the mixing ratio ranges from 30 nmol/mol to 300 nmol/mol at the marine boundary layers and from 100 nmol/mol to more than 500 nmol/mol in urban areas(1). In order to study temporal trends and regional variations of the level of CO, the National Oceanic & Atmospheric Administration/Earth System Research Laboratory-Global Monitoring Division (NOAA/ESRL-GMD(2)) has played a key role as the designated Central Calibration Laboratory (CCL) within the frame of the World Meteorological Organization (WMO) Global Atmosphere Watch (GAW) program. NOAA/ESRL-GMD provides natural air standards, analyzed for CO, to WMO GAW participants. Since the structure of WMO traceability chain appears hierarchical and explicit all over the world, WMO intends to improve the CO measurement compatibility to up to 2 ppb (in case of extensive compatibility goal: 5 ppb, GAW report No. 213(3)) in order to ensure compatibility through the GAW network. Nevertheless, accurate measurement of CO at an ambient level has proven to be difficult due to the lack of stability in cylinders. For these reasons, it is necessary that measured results are compared among the values assigned by various NMIs. This key comparison was initially proposed to be aimed at a CO/N2 standard in the 2010 CCQM meeting by KRISS. With participation of FMI, NOAA, and Empa, a modified scheme of CO/air standards was developed for the purpose of atmospheric observations and co-operative support to WMO/GAW activities. Therefore, the purpose of the comparison is to support the measurement capability of CO at an ambient level of 350 nmol/mol. Further, this key comparison is expected to contribute to the establishment of

  20. ClusCo: clustering and comparison of protein models.

    PubMed

    Jamroz, Michal; Kolinski, Andrzej

    2013-02-22

    The development, optimization and validation of protein modeling methods require efficient tools for structural comparison. Frequently, a large number of models need to be compared with the target native structure. The main reason for the development of Clusco software was to create a high-throughput tool for all-versus-all comparison, because calculating similarity matrix is the one of the bottlenecks in the protein modeling pipeline. Clusco is fast and easy-to-use software for high-throughput comparison of protein models with different similarity measures (cRMSD, dRMSD, GDT_TS, TM-Score, MaxSub, Contact Map Overlap) and clustering of the comparison results with standard methods: K-means Clustering or Hierarchical Agglomerative Clustering. The application was highly optimized and written in C/C++, including the code for parallel execution on CPU and GPU, which resulted in a significant speedup over similar clustering and scoring computation programs.

  1. Key Competencies. Second Edition.

    ERIC Educational Resources Information Center

    Haworth, David; Browne, Geoff

    Key competencies (or generic skills) have been specified in four sources: Further Education Unit (FEU), United Kingdom (1987); Finn Report (1991) and Mayer Committee (1992), Australia; U.S. Labor Secretary's Commission on Achieving Necessary Skills (SCANS) (June 1991); and Butterworth and Lovell (1983), New South Wales. A comparison of the four…

  2. Final report on the EURAMET.M.FF-K4.2.2014 volume comparison at 100 μL—calibration of micropipettes

    NASA Astrophysics Data System (ADS)

    Batista, Elsa; Matus, Michael; Metaxiotou, Zoe; Tudor, Maria; Lenard, Elzbieta; Buker, Oliver; Wennergren, Per; Piluri, Erinda; Miteva, Mariana; Vicarova, Martina; Vospĕlová, Alena; Turnsek, Urska; Micic, Ljiljana; Grue, Lise-Lote; Mihailovic, Mirjana; Sarevska, Anastazija

    2017-01-01

    During the EURAMET TC-F meeting of 2014 and following the finalization of CCM.FF-K4.2.2011 comparison, it was agreed to start a Regional Key Comparison (KC) on volume measurements using two 100 μL micropipettes (piston pipettes) allowing the participating laboratories to assess the agreement of their results and uncertainties. Two 100 μL micropipettes were tested by 15 participants. One participant was not a member or associate member of the BIPM and was be removed from this report. The comparison started in July 2015 and ended in March 2016. The Volume and Flow Laboratory of the Portuguese Institute for Quality (IPQ) was the pilot laboratory and performed the initial and final measurements of the micropipettes. The micropipettes showed a stable volume during the whole comparison, which was confirmed by the results from the pilot laboratory. The original results of all participant NMIs were corrected to the standard atmospheric pressure in order to compare results under the same calibration conditions, and the contribution of the 'process-related handling contribution' was added to the uncertainty budget of each participant. In general the declared CMCs are in accordance with the KCDB. For the micropipette 354828Z, two laboratories had inconsistent results. For micropipette 354853Z, three laboratories had inconsistent results. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report of international comparison APMP.QM-S2.2015 of oxygen in nitrogen at 0.2 mol/mol

    NASA Astrophysics Data System (ADS)

    Aoki, Nobuyuki; Shimosaka, Takuya; Lin, Tsai-Yin; Liu, Hsin-Wang; Huang, Chiung-Kun; Wongjuk, Arnuttachai; Rattanasombat, Soponrat; Sinweeruthai, Ratirat; Uehara, Shinji; Aleksandrov, Vladimir

    2017-01-01

    This document describes the results of the supplementary comparison for oxygen in nitrogen gas mixture. The nominal amount-of-substance fraction of oxygen is 0.20 mol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. APMP supplementary comparison report of absorbed dose rate in tissue for beta radiation (BIPM KCDB: APMP.RI(I)-S2)

    NASA Astrophysics Data System (ADS)

    Kato, M.; Kurosawa, T.; Saito, N.; Kadni, T. B.; Kim, I. J.; Kim, B. C.; Yi, C.-Y.; Pungkun, V.; Chu, C.-H.

    2017-01-01

    The supplementary comparison of absorbed dose rate in tissue for beta radiation (APMP.RI(I)-S2) was performed with five national metrology institutes in 2013 and 2014. Two commercial thin window ionization chambers were used as transfer instruments and circulated among the participants. Two of the NMIs measured the calibration coefficients of the chambers in reference fields produced from Pm-147, Kr-85 and Sr-90/Y-90, while the other three measured those only in Sr-90/Y-90 beta-particle field. The degree of equivalence for the participants was determined and this comparison verifies the calibration capabilities of the participating laboratories. In addition, most of the results of this comparison are consistent with another international comparison (EUROMET.RI(I)-S2) reported before this work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Environmental and economic comparisons of the satellite power system and six alternative energy technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitfield, R.G.; Habegger, L.J.; Levine, E.P.

    1981-04-01

    The objective of the comparative assessment is to provide an initial, traceable and consistent comparison of the SPS and selected current, near-term, and advanced energy technologies. Terrestrial alternatives were selected, and their cost, performance, and environmental and societal attributes were specified for use in the comparison with the SPS in the post-2000 era. The framework for comparisons was established. The SPS was compared with alternative systems in terms of key issues such as life-cycle cost and environmental impacts. The results of the assessments were assembled and integrated into a consistent comparative assessment. Environmental and economic effects are evaluated, which weremore » subdivided into the following issue areas: human health and safety, environmental welfare, resources (land, materials, energy, water, labor), macroeconomics, socioeconomics, and institutional. These evaluations were based on technology characterization data and alternative futures scenarios, which were developed as part of CDEP by supporting studies. The technologies and the scenarios are described. An additional major issue area concerned the cost and performance of the SPS and the alternative technologies: results in this area provided part of the basis of the macroeconomic analyses. 159 references.« less

  6. Comparison Promotes Learning and Transfer of Relational Categories

    ERIC Educational Resources Information Center

    Kurtz, Kenneth J.; Boukrina, Olga; Gentner, Dedre

    2013-01-01

    We investigated the effect of co-presenting training items during supervised classification learning of novel relational categories. Strong evidence exists that comparison induces a structural alignment process that renders common relational structure more salient. We hypothesized that comparisons between exemplars would facilitate learning and…

  7. 40 CFR 761.326 - Conducting the comparison study.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Conducting the comparison study. 761.326 Section 761.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the...

  8. 40 CFR 761.326 - Conducting the comparison study.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Conducting the comparison study. 761.326 Section 761.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the...

  9. 40 CFR 761.326 - Conducting the comparison study.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Conducting the comparison study. 761.326 Section 761.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the...

  10. Comparison analysis for classification algorithm in data mining and the study of model use

    NASA Astrophysics Data System (ADS)

    Chen, Junde; Zhang, Defu

    2018-04-01

    As a key technique in data mining, classification algorithm was received extensive attention. Through an experiment of classification algorithm in UCI data set, we gave a comparison analysis method for the different algorithms and the statistical test was used here. Than that, an adaptive diagnosis model for preventive electricity stealing and leakage was given as a specific case in the paper.

  11. COMPARISON FRICTION: EXPERIMENTAL EVIDENCE FROM MEDICARE DRUG PLANS*

    PubMed Central

    Kling, Jeffrey R.; Mullainathan, Sendhil; Shafir, Eldar; Vermeulen, Lee; Wrobel, Marian V.

    2011-01-01

    Consumers need information to compare alternatives for markets to function efficiently. Recognizing this, public policies often pair competition with easy access to comparative information. The implicit assumption is that comparison friction—the wedge between the availability of comparative information and consumers’ use of it—is inconsequential because information is readily available and consumers will access this information and make effective choices. We examine the extent of comparison friction in the market for Medicare Part D prescription drug plans in the United States. In a randomized field experiment, an intervention group received a letter with personalized cost information. That information was readily available for free and widely advertised. However, this additional step—providing the information rather than having consumers actively access it—had an impact. Plan switching was 28 percent in the intervention group, versus 17 percent in the comparison group, and the intervention caused an average decline in predicted consumer cost of about $100 per year among letter recipients—roughly 5 percent of the cost in the comparison group. Our results suggest that comparison friction can be large even when the cost of acquiring information is small, and may be relevant for a wide range of public policies that incorporate consumer choice. PMID:22454838

  12. Automatic video shot boundary detection using k-means clustering and improved adaptive dual threshold comparison

    NASA Astrophysics Data System (ADS)

    Sa, Qila; Wang, Zhihui

    2018-03-01

    At present, content-based video retrieval (CBVR) is the most mainstream video retrieval method, using the video features of its own to perform automatic identification and retrieval. This method involves a key technology, i.e. shot segmentation. In this paper, the method of automatic video shot boundary detection with K-means clustering and improved adaptive dual threshold comparison is proposed. First, extract the visual features of every frame and divide them into two categories using K-means clustering algorithm, namely, one with significant change and one with no significant change. Then, as to the classification results, utilize the improved adaptive dual threshold comparison method to determine the abrupt as well as gradual shot boundaries.Finally, achieve automatic video shot boundary detection system.

  13. Comparison of LASSO and GPS time transfers

    NASA Technical Reports Server (NTRS)

    Lewandowski, W.; Petit, G.; Baumont, F.; Fridelance, P.; Gaignebet, J.; Grudler, P.; Veillet, C.; Wiant, J.; Klepczynski, W. J.

    1994-01-01

    The LASSO is a technique which should allow the comparison of remote atomic clocks with sub-nanosecond precision and accuracy. The first successful time transfer using LASSO has been carried out between the Observatoire de la Cote d'Azur in France and the McDonald Observatory in Texas, United States. This paper presents a preliminary comparison of LASSO time transfer with GPS common-view time transfer.

  14. Comparison of ORSAT and SCARAB Reentry Analysis Tools for a Generic Satellite Test Case

    NASA Technical Reports Server (NTRS)

    Kelley, Robert L.; Hill, Nicole M.; Rochelle, W. C.; Johnson, Nicholas L.; Lips, T.

    2010-01-01

    Reentry analysis is essential to understanding the consequences of the full life cycle of a spacecraft. Since reentry is a key factor in spacecraft development, NASA and ESA have separately developed tools to assess the survivability of objects during reentry. Criteria such as debris casualty area and impact energy are particularly important to understanding the risks posed to people on Earth. Therefore, NASA and ESA have undertaken a series of comparison studies of their respective reentry codes for verification and improvements in accuracy. The NASA Object Reentry Survival Analysis Tool (ORSAT) and the ESA Spacecraft Atmospheric Reentry and Aerothermal Breakup (SCARAB) reentry analysis tools serve as standard codes for reentry survivability assessment of satellites. These programs predict whether an object will demise during reentry and calculate the debris casualty area of objects determined to survive, establishing the reentry risk posed to the Earth's population by surviving debris. A series of test cases have been studied for comparison and the most recent uses "Testsat," a conceptual satellite composed of generic parts, defined to use numerous simple shapes and various materials for a better comparison of the predictions of these two codes. This study is an improvement on the others in this series because of increased consistency in modeling techniques and variables. The overall comparison demonstrated that the two codes arrive at similar results. Either most objects modeled resulted in close agreement between the two codes, or if the difference was significant, the variance could be explained as a case of semantics in the model definitions. This paper presents the main results of ORSAT and SCARAB for the Testsat case and discusses the sources of any discovered differences. Discussion of the results of previous comparisons is made for a summary of differences between the codes and lessons learned from this series of tests.

  15. Learning Radiological Appearances of Diseases: Does Comparison Help?

    ERIC Educational Resources Information Center

    Kok, Ellen M.; de Bruin, Anique B. H.; Robben, Simon G. F.; van Merrienboer, Jeroen J. G.

    2013-01-01

    Comparison learning is a promising approach for learning complex real-life visual tasks. When medical students study radiological appearances of diseases, comparison of images showing diseases with images showing no abnormalities could help them learn to discriminate relevant, disease-related information. Medical students studied 12 diseases on…

  16. Activity measurements of the radionuclide 124Sb by the LNE-LNHB, France for the ongoing comparison BIPM.RI(II)-K1.Sb-124

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Ratel, G.; Moune, M.; Bobin, C.

    2011-01-01

    In 2007, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of 124Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Final report on AFRIMETS comparison of liquid in glass thermometer calibrations from -35 °C to 250 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans; Kebede Ejigu, Efrem; Madiba, Tshifhiwa; du Clou, Sven; Chibaya, Blessing; Mwazi, Victor; Kajane, Tebogo; Mundembe, Victor; Kwong, Christian Ng Ha; Madeleine, Gilbert

    2017-01-01

    A Regional Metrology Organization (RMO) supplementary comparison of liquid in glass thermometer (AFRIMETS.T-S5) was carried out by the National Metrology Institute of South Africa (NMISA), Zimbabwe Scientific & Industrial Research & Development Centre—National Metrology Institute (SIRDC-NMI), Zambia Bureau of Standards (ZABS), Botswana Bureau of Standards (BOBS), Namibian Standards Institute (NSI), Mauritius Standards Bureau (MSB) and Seychelles Bureau of Standards (SBS) between January and September 2016. The temperature range of the inter comparison is -35 °C to 250 °C. The results of this comparison are reported here, along with descriptions of the Artefacts used. This report also presents the uncertainty budget of each participant. The results are analysed and normalized error (En) values are reported. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on APMP.M.P-S3: Results of the supplementary comparison in gas media in the range 1.77 MPa to 6.8 MPa

    NASA Astrophysics Data System (ADS)

    Owen, N.; Bergoglio, M.

    2013-01-01

    This report provides the results of the supplementary bilateral comparison APMP.M.P-S3 between NMI Australia (NMIA) and INRIM, Italy executed from November 2010 to November 2011. NMIA acted as the pilot laboratory and provided a Ruska G series piston gauge as the transfer standard, with a nominal area 16.8 mm2 requiring a nominal load of 12 kg to balance a pressure of 7.0 MPa. The purpose of this supplementary bilateral comparison was to provide data for linking NMIA to CCM.P-K1.c in the pressure range greater than 4 MPa to extend the range covered by key comparison APMP.M.P-K1c. The original protocol called for the pressure range from 80 kPa to 6.80 MPa. Both participants agreed to limit this comparison range to 1.77 MPa to 6.50 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Issues concerning international comparison of free-field calibrations of acoustical standards

    NASA Astrophysics Data System (ADS)

    Nedzelnitsky, Victor

    2002-11-01

    Primary free-field calibrations of laboratory standard microphones by the reciprocity method establish these microphones as reference standard devices for calibrating working standard microphones, other measuring microphones, and practical instruments such as sound level meters and personal sound exposure meters (noise dosimeters). These primary, secondary, and other calibrations are indispensable to the support of regulatory requirements, standards, and product characterization and quality control procedures important for industry, commerce, health, and safety. International Electrotechnical Commission (IEC) Technical Committee 29 Electroacoustics produces international documentary standards, including standards for primary and secondary free-field calibration and measurement procedures and their critically important application to practical instruments. This paper addresses some issues concerning calibrations, standards activities, and the international key comparison of primary free-field calibrations of IEC-type LS2 laboratory standard microphones that is being planned by the Consultative Committee for Acoustics, Ultrasound, and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM). This comparison will include free-field calibrations by the reciprocity method at participating major national metrology laboratories throughout the world.

  20. Assertiveness, submissive behaviour and social comparison.

    PubMed

    Gilbert, P; Allan, S

    1994-09-01

    This paper explores the relationship between a new assertiveness measure (the Scale for Interpersonal Behaviour--SIB), social comparison and submissive behaviour. The paper investigates these measures in relation to the personality traits of neuroticism and introversion. Findings suggest: (a) that social comparison may be an important variable in assertiveness and submissive behaviour and shows a strong relationship to neuroticism and introversion; (b) that submissive behaviour is not the mirror opposite of assertive behaviour; and (c) submissive behaviour seems more strongly associated with introversion and neuroticism than assertive performance.

  1. Heat strain models applicable for protective clothing: Comparison of core temperature response. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, R.R.; McLellan, T.M.; Withey, W.R.

    This report represents the results of TTCP-UTP6 efforts on modeling aspects when chemical protective ensembles are worn which need to be considered in warm environments. Since 1983, a significant data base has been collected using human experimental studies and wide clothing systems from which predictive modeling equations have been developed with individuals working in temperate and hot environments, but few comparisons of the -- results from various model outputs have ever been carried out. This initial comparison study was part of a key technical area (KIA) project for The Technical Cooperation Program (TTCP) UTP-6 working party. A modeling workshop wasmore » conducted in Toronto, Canada on 9-10 June 1994 to discuss the data reduction and results acquired in an initial clothing analysis study of TTCP using various chemical protective garments. To our knowledge, no comprehensive study to date has ever focused on comparing experimental results using an international standardized heat stress procedure matched to physiological outputs from various model predictions in individuals dressed in chemical protective clothing systems. This is the major focus of this TTCP key technical study. This technical report covers one aspect of the working party`s results.« less

  2. Children's body image and social comparisons with peers and the media.

    PubMed

    Tatangelo, Gemma L; Ricciardelli, Lina A

    2017-05-01

    Social comparisons are related to the development of body dissatisfaction among adolescents and adults, yet this relationship remains relatively unexamined among children. This study examines children's peer and media-related social comparisons, and how this impacts on their body image. Children aged 8-10 years completed interviews (17 girls and 19 boys in individual interviews, and 16 girls and 16 boys in focus groups). Analyses revealed that appearance-related comparisons were more common among girls, whereas sports/ability-related comparisons were more common for boys. In addition, boys viewed media comparisons as inspiring, whereas girls reported negative emotions. Implications for future research and prevention programmes are discussed.

  3. Interpreting indirect treatment comparisons and network meta-analysis for health-care decision making: report of the ISPOR Task Force on Indirect Treatment Comparisons Good Research Practices: part 1.

    PubMed

    Jansen, Jeroen P; Fleurence, Rachael; Devine, Beth; Itzler, Robbin; Barrett, Annabel; Hawkins, Neil; Lee, Karen; Boersma, Cornelis; Annemans, Lieven; Cappelleri, Joseph C

    2011-06-01

    Evidence-based health-care decision making requires comparisons of all relevant competing interventions. In the absence of randomized, controlled trials involving a direct comparison of all treatments of interest, indirect treatment comparisons and network meta-analysis provide useful evidence for judiciously selecting the best choice(s) of treatment. Mixed treatment comparisons, a special case of network meta-analysis, combine direct and indirect evidence for particular pairwise comparisons, thereby synthesizing a greater share of the available evidence than a traditional meta-analysis. This report from the ISPOR Indirect Treatment Comparisons Good Research Practices Task Force provides guidance on the interpretation of indirect treatment comparisons and network meta-analysis to assist policymakers and health-care professionals in using its findings for decision making. We start with an overview of how networks of randomized, controlled trials allow multiple treatment comparisons of competing interventions. Next, an introduction to the synthesis of the available evidence with a focus on terminology, assumptions, validity, and statistical methods is provided, followed by advice on critically reviewing and interpreting an indirect treatment comparison or network meta-analysis to inform decision making. We finish with a discussion of what to do if there are no direct or indirect treatment comparisons of randomized, controlled trials possible and a health-care decision still needs to be made. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  4. PFLOTRAN-RepoTREND Source Term Comparison Summary.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frederick, Jennifer M.

    Code inter-comparison studies are useful exercises to verify and benchmark independently developed software to ensure proper function, especially when the software is used to model high-consequence systems which cannot be physically tested in a fully representative environment. This summary describes the results of the first portion of the code inter-comparison between PFLOTRAN and RepoTREND, which compares the radionuclide source term used in a typical performance assessment.

  5. The development of an automatic recognition system for earmark and earprint comparisons.

    PubMed

    Junod, Stéphane; Pasquier, Julien; Champod, Christophe

    2012-10-10

    The value of earmarks as an efficient means of personal identification is still subject to debate. It has been argued that the field is lacking a firm systematic and structured data basis to help practitioners to form their conclusions. Typically, there is a paucity of research guiding as to the selectivity of the features used in the comparison process between an earmark and reference earprints taken from an individual. This study proposes a system for the automatic comparison of earprints and earmarks, operating without any manual extraction of key-points or manual annotations. For each donor, a model is created using multiple reference prints, hence capturing the donor within source variability. For each comparison between a mark and a model, images are automatically aligned and a proximity score, based on a normalized 2D correlation coefficient, is calculated. Appropriate use of this score allows deriving a likelihood ratio that can be explored under known state of affairs (both in cases where it is known that the mark has been left by the donor that gave the model and conversely in cases when it is established that the mark originates from a different source). To assess the system performance, a first dataset containing 1229 donors elaborated during the FearID research project was used. Based on these data, for mark-to-print comparisons, the system performed with an equal error rate (EER) of 2.3% and about 88% of marks are found in the first 3 positions of a hitlist. When performing print-to-print transactions, results show an equal error rate of 0.5%. The system was then tested using real-case data obtained from police forces. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Selecting Evaluation Comparison Groups: A Cluster Analytic Approach.

    ERIC Educational Resources Information Center

    Davis, Todd Mclin; McLean, James E.

    A persistent problem in the evaluation of field-based projects is the lack of no-treatment comparison groups. Frequently, potential comparison groups are confounded by socioeconomic, racial, or other factors. Among the possible methods for dealing with this problem are various matching procedures, but they are cumbersome to use with multiple…

  7. The Dynamics of Metaphors: Class-Inclusion or Comparison?

    ERIC Educational Resources Information Center

    Drunkenmölle, Tomas

    2012-01-01

    In current literature, metaphor is treated as either an instance of implicit comparison or as a nonliteral class-inclusion statement. I will argue that, contrary to these positions, the notions of comparison and class-inclusion are not mutually exclusive in character but rather complementary cognitive concepts which entail one another. While…

  8. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S1

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S2

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Comparison Campaign of VLBI Data Analysis Software - First Results

    NASA Technical Reports Server (NTRS)

    Plank, Lucia; Bohm, Johannes; Schuh, Harald

    2010-01-01

    During the development of the Vienna VLBI Software VieVS at the Institute of Geodesy and Geophysics at Vienna University of Technology, a special comparison setup was developed with the goal of easily finding links between deviations of results achieved with different software packages and certain parameters of the observation. The object of comparison is the computed time delay, a value calculated for each observation including all relevant models and corrections that need to be applied in geodetic VLBI analysis. Besides investigating the effects of the various models on the total delay, results of comparisons between VieVS and Occam 6.1 are shown. Using the same methods, a Comparison Campaign of VLBI data analysis software called DeDeCC is about to be launched within the IVS soon.

  11. Acceleration of Binding Site Comparisons by Graph Partitioning.

    PubMed

    Krotzky, Timo; Klebe, Gerhard

    2015-08-01

    The comparison of protein binding sites is a prominent task in computational chemistry and has been studied in many different ways. For the automatic detection and comparison of putative binding cavities the Cavbase system has been developed which uses a coarse-grained set of pseudocenters to represent the physicochemical properties of a binding site and employs a graph-based procedure to calculate similarities between two binding sites. However, the comparison of two graphs is computationally quite demanding which makes large-scale studies such as the rapid screening of entire databases hardly feasible. In a recent work, we proposed the method Local Cliques (LC) for the efficient comparison of Cavbase binding sites. It employs a clique heuristic to detect the maximum common subgraph of two binding sites and an extended graph model to additionally compare the shape of individual surface patches. In this study, we present an alternative to further accelerate the LC method by partitioning the binding-site graphs into disjoint components prior to their comparisons. The pseudocenter sets are split with regard to their assigned phyiscochemical type, which leads to seven much smaller graphs than the original one. Applying this approach on the same test scenarios as in the former comprehensive way results in a significant speed-up without sacrificing accuracy. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Self-comparisons as motivators for healthy behavior.

    PubMed

    Shakya, Holly B; Christakis, Nicholas A; Fowler, James H

    2015-12-01

    We explored whether individuals' comparison of themselves to their social contacts, specifically feeling fitter or thinner than friends, is a significant predictor of three weight-loss behaviors (dieting, reducing alcohol, exercising). We used a longitudinal survey of a national sample of Americans (N = 20,373) to measure respondents' personal social networks and their self-comparisons to their social contacts at two annual waves. Participants who felt thinner than friends in Wave 1 had 1.16 lower odds of dieting in Wave 2. Those who felt fitter than friends in Wave 1 had 1.10 times higher odds of reducing alcohol and 1.18 times higher odds of exercising in Wave 2. We found that 20% of the relationship between feeling thin at baseline and subsequent dieting may be because feeling heavier than friends makes one want to lose weight. This same dynamic accounts for 25% of the relationship between feeling fit and dieting and 12% of the relationship between feeling thin and reducing alcohol. These results suggest that normative self-comparison with important others is a potentially salient determinant of obesity-related health behavior and appears to work differently depending upon the behavior. Interventions may benefit from exploiting social comparisons in targeted ways. © 2015 The Obesity Society.

  13. Numerical Order and Quantity Processing in Number Comparison

    ERIC Educational Resources Information Center

    Turconi, Eva; Campbell, Jamie I. D.; Seron, Xavier

    2006-01-01

    We investigated processing of numerical order information and its relation to mechanisms of numerical quantity processing. In two experiments, performance on a quantity-comparison task (e.g. 2 5; which is larger?) was compared with performance on a relative-order judgment task (e.g. 2 5; ascending or descending order?). The comparison task…

  14. Task-Driven Comparison of Topic Models.

    PubMed

    Alexander, Eric; Gleicher, Michael

    2016-01-01

    Topic modeling, a method of statistically extracting thematic content from a large collection of texts, is used for a wide variety of tasks within text analysis. Though there are a growing number of tools and techniques for exploring single models, comparisons between models are generally reduced to a small set of numerical metrics. These metrics may or may not reflect a model's performance on the analyst's intended task, and can therefore be insufficient to diagnose what causes differences between models. In this paper, we explore task-centric topic model comparison, considering how we can both provide detail for a more nuanced understanding of differences and address the wealth of tasks for which topic models are used. We derive comparison tasks from single-model uses of topic models, which predominantly fall into the categories of understanding topics, understanding similarity, and understanding change. Finally, we provide several visualization techniques that facilitate these tasks, including buddy plots, which combine color and position encodings to allow analysts to readily view changes in document similarity.

  15. Other better versus self better in baboons: an evolutionary approach of social comparison

    PubMed Central

    2017-01-01

    Comparing oneself with others is an important characteristic of human social life, but the link between human and non-human forms of social comparison remains largely unknown. The present study used a computerized task presented in a social context to explore psychological mechanisms supporting social comparison in baboons and compare major findings with those usually observed in humans. We found that the effects of social comparison on subject's performance were guided both by similarity (same versus different sex) and by task complexity. Comparing oneself with a better-off other (upward comparison) increased performance when the other was similar rather than dissimilar, and a reverse effect was obtained when the self was better (downward comparison). Furthermore, when the other was similar, upward comparison led to a better performance than downward comparison. Interestingly, the beneficial effect of upward comparison on baboons' performance was only observed during simple task. Our results support the hypothesis of shared social comparison mechanisms in human and non-human primates. PMID:28539512

  16. Delayed temporal discrimination in pigeons: A comparison of two procedures

    PubMed Central

    Chatlosh, Diane L.; Wasserman, Edward A.

    1987-01-01

    A within-subjects comparison was made of pigeons' performance on two temporal discrimination procedures that were signaled by differently colored keylight samples. During stimulus trials, a peck on the key displaying a slanted line was reinforced following short keylight samples, and a peck on the key displaying a horizontal line was reinforced following long keylight samples, regardless of the location of the stimuli on those two choice keys. During position trials, a peck on the left key was reinforced following short keylight samples and a peck on the right key was reinforced following long keylight samples, regardless of which line stimulus appeared on the correct key. Thus, on stimulus trials, the correct choice key could not be discriminated prior to the presentation of the test stimuli, whereas on position trials, the correct choice key could be discriminated during the presentation of the sample stimulus. During Phase 1, with a 0-s delay between sample and choice stimuli, discrimination learning was faster on position trials than on stimulus trials for all 4 birds. During Phase 2, 0-, 0.5-, and 1.0-s delays produced differential loss of stimulus control under the two tasks for 2 birds. Response patterns during the delay intervals provided some evidence for differential mediation of the two delayed discriminations. These between-task differences suggest that the same processes may not mediate performance in each. PMID:16812483

  17. Inconsistency between direct and indirect comparisons of competing interventions: meta-epidemiological study.

    PubMed

    Song, Fujian; Xiong, Tengbin; Parekh-Bhurke, Sheetal; Loke, Yoon K; Sutton, Alex J; Eastwood, Alison J; Holland, Richard; Chen, Yen-Fu; Glenny, Anne-Marie; Deeks, Jonathan J; Altman, Doug G

    2011-08-16

    To investigate the agreement between direct and indirect comparisons of competing healthcare interventions. Meta-epidemiological study based on sample of meta-analyses of randomised controlled trials. Data sources Cochrane Database of Systematic Reviews and PubMed. Inclusion criteria Systematic reviews that provided sufficient data for both direct comparison and independent indirect comparisons of two interventions on the basis of a common comparator and in which the odds ratio could be used as the outcome statistic. Inconsistency measured by the difference in the log odds ratio between the direct and indirect methods. The study included 112 independent trial networks (including 1552 trials with 478,775 patients in total) that allowed both direct and indirect comparison of two interventions. Indirect comparison had already been explicitly done in only 13 of the 85 Cochrane reviews included. The inconsistency between the direct and indirect comparison was statistically significant in 16 cases (14%, 95% confidence interval 9% to 22%). The statistically significant inconsistency was associated with fewer trials, subjectively assessed outcomes, and statistically significant effects of treatment in either direct or indirect comparisons. Owing to considerable inconsistency, many (14/39) of the statistically significant effects by direct comparison became non-significant when the direct and indirect estimates were combined. Significant inconsistency between direct and indirect comparisons may be more prevalent than previously observed. Direct and indirect estimates should be combined in mixed treatment comparisons only after adequate assessment of the consistency of the evidence.

  18. Resource Allocation and Resident Outcomes In Nursing Homes: Comparisons between the Best and Worst1

    PubMed Central

    Anderson, Ruth A.; Hsieh, Pi-Ching; Su, Hui-Fang

    2005-01-01

    The purpose of this study was to identify patterns of resource allocation that related to resident outcomes in nursing homes. Data on structure, staffing levels, salaries, cost, casemix, and resident outcomes were obtained from state-level, administrative databases on 494 nursing homes. We identified two sets of comparison groups and showed that the group of homes with the greatest percentage of improvement in resident outcomes had higher levels of RN staffing and higher costs. However, comparison groups based on best/worst average outcomes did not differ in resource allocation patterns. Additional analysis demonstrated that when controlling for RN staffing, resident outcomes in high and low cost homes did not differ. The results suggest that, although RN staffing is more expensive, it is key to improving resident outcomes. PMID:9679807

  19. Comparison of the scanned pages of the contractual documents

    NASA Astrophysics Data System (ADS)

    Andreeva, Elena; Arlazarov, Vladimir V.; Manzhikov, Temudzhin; Slavin, Oleg

    2018-04-01

    In this paper the problem statement is given to compare the digitized pages of the official papers. Such problem appears during the comparison of two customer copies signed at different times between two parties with a view to find the possible modifications introduced on the one hand. This problem is a practically significant in the banking sector during the conclusion of contracts in a paper format. The method of comparison based on the recognition, which consists in the comparison of two bag-of-words, which are the recognition result of the master and test pages, is suggested. The described experiments were conducted using the OCR Tesseract and the siamese neural network. The advantages of the suggested method are the steady operation of the comparison algorithm and the high exacting precision, and one of the disadvantages is the dependence on the chosen OCR.

  20. The Mediating Roles of Upward Social Comparison and Self-esteem and the Moderating Role of Social Comparison Orientation in the Association between Social Networking Site Usage and Subjective Well-Being.

    PubMed

    Wang, Jin-Liang; Wang, Hai-Zhen; Gaskin, James; Hawk, Skyler

    2017-01-01

    The increased pervasiveness of social media use has raised questions about potential effects on users' subjective well-being, with studies reaching contrasting conclusions. To reconcile these discrepancies and shed new light on this phenomenon, the current study examined: (1) whether upward social comparison and self-esteem mediate the association between social networking site (SNS) usage and users' subjective well-being, and (2) whether the association between SNS usage and upward social comparison is moderated by users' social comparison orientation. Data from 696 participants were collected. Structural equation modeling revealed that upward social comparison and self-esteem mediated the relationship between SNS usage and users' subjective well-being. We found that social comparison orientation moderated the association between passive SNS usage and users' upward social comparison. Specifically, social comparison orientation strengthened the association between passive SNS usage and upward social comparison. The results might suggest a process through which passive SNS usage is related to subjective well-being, and identify a context under which these associations may differ.

  1. On relative distortion in fingerprint comparison.

    PubMed

    Kalka, Nathan D; Hicklin, R Austin

    2014-11-01

    When fingerprints are deposited, non-uniform pressure in conjunction with the inherent elasticity of friction ridge skin often causes linear and non-linear distortions in the ridge and valley structure. The effects of these distortions must be considered during analysis of fingerprint images. Even when individual prints are not notably distorted, relative distortion between two prints can have a serious impact on comparison. In this paper we discuss several metrics for quantifying and visualizing linear and non-linear fingerprint deformations, and software tools to assist examiners in accounting for distortion in fingerprint comparisons. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. The development and validation of the Physical Appearance Comparison Scale-3 (PACS-3).

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2018-05-21

    Appearance comparison processes are implicated in the development of body-image disturbance and disordered eating. The Physical Appearance Comparison Scale-Revised (PACS-R) assesses the simple frequency of appearance comparisons; however, research has suggested that other aspects of appearance comparisons (e.g., comparison direction) may moderate the association between comparisons and their negative outcomes. In the current study, the PACS-R was revised to examine aspects of comparisons with relevance to body-image and eating outcomes. Specifically, the measure was modified to examine (a) dimensions of physical appearance relevant to men and women (i.e., weight-shape, muscularity, and overall physical appearance), (b) comparisons with proximal and distal targets, (c) upward versus downward comparisons, and (d) the acute emotional impact of comparisons. The newly revised measure, labeled the PACS-3, along with existing measures of appearance comparison, body satisfaction, eating pathology, and self-esteem, was completed by 1,533 college men and women. Exploratory and confirmatory factor analyses were conducted to examine the factor structure of the PACS-3. In addition, the reliability, convergent validity, and incremental validity of the PACS-3 scores were examined. The final PACS-3 comprises 27 items and 9 subscales: Proximal: Frequency, Distal: Frequency, Muscular: Frequency, Proximal: Direction, Distal: Direction, Muscular: Direction, Proximal: Effect, Distal: Effect, and Muscular: Effect. the PACS-3 subscale scores demonstrated good reliability and convergent validity. Moreover, the PACS-3 subscales greatly improved the prediction of body satisfaction and disordered eating relative to existing measures of appearance comparison. Overall, the PACS-3 improves upon existing scales and offers a comprehensive assessment of appearance-comparison processes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  3. Supplementary comparison of 500 microgram, 200 microgram, 100 microgram and 50 microgram weights—EURAMET.M.M-S9

    NASA Astrophysics Data System (ADS)

    Davidson, Stuart; Valcu, Adriana; Medina, Nieves; Zuda, Jaroslav; Snopko, Laurenc; Kolozinska, Irena

    2017-01-01

    A comparison of sub-milligram mass standards was undertaken within EURAMET between NPL (as the pilot laboratory), INM (Romania), CEM (Spain), CMI (Czech Republic), SMU (Slovakia) and NSC IM (Ukraine). The weights circulated had nominal values of 500 micrograms, 200 micrograms (2 weights), 100 micrograms and 50 micrograms. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Exercise self-identity: interactions with social comparison and exercise behaviour.

    PubMed

    Verkooijen, Kirsten T; de Bruijn, Gert-Jan

    2013-01-01

    Possible interactions among exercise self-identity, social comparison and exercise behaviour were explored in a sample of 417 undergraduate students (mean age = 21.5, SD = 3.0; 73% female). Two models were examined using self-report data; (1) a mediation model which proposed an association between social comparison and exercise behaviour mediated by exercise self-identity and (2) a moderation model proposing an association between exercise behaviour and self-identity moderated by social comparison. Results of the mediation analyses revealed partial mediation of the social comparison--exercise behaviour relationship by self-identity in females. Results of the moderation analyses revealed in males a significant interaction of social comparison with exercise behaviour in the prediction of self-identity - the positive association between exercise behaviour and exercise self-identity showed only significant among male students who believed to exercise equally much or less than peers. Possible explanations and implications for exercise promotion are discussed.

  5. Comparison-Bot: an Automated Preliminary-Final Report Comparison System.

    PubMed

    Kalaria, Amit D; Filice, Ross W

    2016-06-01

    Regular comparison of preliminary to final reports is a critical part of radiology resident and fellow education as prior research has documented substantial preliminary to final discrepancies. Unfortunately, there are many barriers to this comparison: high study volume; overnight rotations without an attending; the ability to finalize reports remotely; the subtle nature of many changes; and lack of easy access to the preliminary report after finalization. We developed a system that automatically compiles and emails a weekly summary of report differences for all residents and fellows. Trainees can also create a custom report using a date range of their choice and can view this data on a resident dashboard. Differences between preliminary and final reports are clearly highlighted with links to the associated study in Picture Archiving and Communication Systems (PACS) for efficient review and learning. Reports with more changes, particularly changes made in the impression, are highlighted to focus attention on those exams with substantive edits. Our system provides an easy way for trainees to review changes to preliminary reports with immediate access to the associated images, thereby improving their educational experience. Departmental surveys showed that our report difference summary is easy to understand and improves the educational experience of our trainees. Additionally, interesting descriptive statistics help us understand how reports are changed by trainee level, by attending, and by exam type. Finally, this system can be easily ported to other departments who have access to their Health Level 7 (HL7) data.

  6. Real medical benefit assessed by indirect comparison.

    PubMed

    Falissard, Bruno; Zylberman, Myriam; Cucherat, Michel; Izard, Valérie; Meyer, François

    2009-01-01

    Frequently, in data packages submitted for Marketing Approval to the CHMP, there is a lack of relevant head-to-head comparisons of medicinal products that could enable national authorities responsible for the approval of reimbursement to assess the Added Therapeutic Value (ASMR) of new clinical entities or line extensions of existing therapies.Indirect or mixed treatment comparisons (MTC) are methods stemming from the field of meta-analysis that have been designed to tackle this problem. Adjusted indirect comparisons, meta-regressions, mixed models, Bayesian network analyses pool results of randomised controlled trials (RCTs), enabling a quantitative synthesis.The REAL procedure, recently developed by the HAS (French National Authority for Health), is a mixture of an MTC and effect model based on expert opinions. It is intended to translate the efficacy observed in the trials into effectiveness expected in day-to-day clinical practice in France.

  7. 30 CFR 206.176 - How do I perform accounting for comparison?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I perform accounting for comparison? 206... REVENUE MANAGEMENT PRODUCT VALUATION Indian Gas § 206.176 How do I perform accounting for comparison? (a... requires accounting for comparison (also referred to as actual dual accounting). Except as provided in...

  8. Inconsistency between direct and indirect comparisons of competing interventions: meta-epidemiological study

    PubMed Central

    Xiong, Tengbin; Parekh-Bhurke, Sheetal; Loke, Yoon K; Sutton, Alex J; Eastwood, Alison J; Holland, Richard; Chen, Yen-Fu; Glenny, Anne-Marie; Deeks, Jonathan J; Altman, Doug G

    2011-01-01

    Objective To investigate the agreement between direct and indirect comparisons of competing healthcare interventions. Design Meta-epidemiological study based on sample of meta-analyses of randomised controlled trials. Data sources Cochrane Database of Systematic Reviews and PubMed. Inclusion criteria Systematic reviews that provided sufficient data for both direct comparison and independent indirect comparisons of two interventions on the basis of a common comparator and in which the odds ratio could be used as the outcome statistic. Main outcome measure Inconsistency measured by the difference in the log odds ratio between the direct and indirect methods. Results The study included 112 independent trial networks (including 1552 trials with 478 775 patients in total) that allowed both direct and indirect comparison of two interventions. Indirect comparison had already been explicitly done in only 13 of the 85 Cochrane reviews included. The inconsistency between the direct and indirect comparison was statistically significant in 16 cases (14%, 95% confidence interval 9% to 22%). The statistically significant inconsistency was associated with fewer trials, subjectively assessed outcomes, and statistically significant effects of treatment in either direct or indirect comparisons. Owing to considerable inconsistency, many (14/39) of the statistically significant effects by direct comparison became non-significant when the direct and indirect estimates were combined. Conclusions Significant inconsistency between direct and indirect comparisons may be more prevalent than previously observed. Direct and indirect estimates should be combined in mixed treatment comparisons only after adequate assessment of the consistency of the evidence. PMID:21846695

  9. Quality Management and Key Performance Indicators in Oncologic Esophageal Surgery.

    PubMed

    Gockel, Ines; Ahlbrand, Constantin Johannes; Arras, Michael; Schreiber, Elke Maria; Lang, Hauke

    2015-12-01

    Ranking systems and comparisons of quality and performance indicators will be of increasing relevance for complex "high-risk" procedures such as esophageal cancer surgery. The identification of evidence-based standards relevant for key performance indicators in esophageal surgery is essential for establishing monitoring systems and furthermore a requirement to enhance treatment quality. In the course of this review, we analyze the key performance indicators case volume, radicality of resection, and postoperative morbidity and mortality, leading to continuous quality improvement. Ranking systems established on this basis will gain increased relevance in highly complex procedures within the national and international comparison and furthermore improve the treatment of patients with esophageal carcinoma.

  10. BLAST Ring Image Generator (BRIG): simple prokaryote genome comparisons

    PubMed Central

    2011-01-01

    Background Visualisation of genome comparisons is invaluable for helping to determine genotypic differences between closely related prokaryotes. New visualisation and abstraction methods are required in order to improve the validation, interpretation and communication of genome sequence information; especially with the increasing amount of data arising from next-generation sequencing projects. Visualising a prokaryote genome as a circular image has become a powerful means of displaying informative comparisons of one genome to a number of others. Several programs, imaging libraries and internet resources already exist for this purpose, however, most are either limited in the number of comparisons they can show, are unable to adequately utilise draft genome sequence data, or require a knowledge of command-line scripting for implementation. Currently, there is no freely available desktop application that enables users to rapidly visualise comparisons between hundreds of draft or complete genomes in a single image. Results BLAST Ring Image Generator (BRIG) can generate images that show multiple prokaryote genome comparisons, without an arbitrary limit on the number of genomes compared. The output image shows similarity between a central reference sequence and other sequences as a set of concentric rings, where BLAST matches are coloured on a sliding scale indicating a defined percentage identity. Images can also include draft genome assembly information to show read coverage, assembly breakpoints and collapsed repeats. In addition, BRIG supports the mapping of unassembled sequencing reads against one or more central reference sequences. Many types of custom data and annotations can be shown using BRIG, making it a versatile approach for visualising a range of genomic comparison data. BRIG is readily accessible to any user, as it assumes no specialist computational knowledge and will perform all required file parsing and BLAST comparisons automatically. Conclusions

  11. BLAST Ring Image Generator (BRIG): simple prokaryote genome comparisons.

    PubMed

    Alikhan, Nabil-Fareed; Petty, Nicola K; Ben Zakour, Nouri L; Beatson, Scott A

    2011-08-08

    Visualisation of genome comparisons is invaluable for helping to determine genotypic differences between closely related prokaryotes. New visualisation and abstraction methods are required in order to improve the validation, interpretation and communication of genome sequence information; especially with the increasing amount of data arising from next-generation sequencing projects. Visualising a prokaryote genome as a circular image has become a powerful means of displaying informative comparisons of one genome to a number of others. Several programs, imaging libraries and internet resources already exist for this purpose, however, most are either limited in the number of comparisons they can show, are unable to adequately utilise draft genome sequence data, or require a knowledge of command-line scripting for implementation. Currently, there is no freely available desktop application that enables users to rapidly visualise comparisons between hundreds of draft or complete genomes in a single image. BLAST Ring Image Generator (BRIG) can generate images that show multiple prokaryote genome comparisons, without an arbitrary limit on the number of genomes compared. The output image shows similarity between a central reference sequence and other sequences as a set of concentric rings, where BLAST matches are coloured on a sliding scale indicating a defined percentage identity. Images can also include draft genome assembly information to show read coverage, assembly breakpoints and collapsed repeats. In addition, BRIG supports the mapping of unassembled sequencing reads against one or more central reference sequences. Many types of custom data and annotations can be shown using BRIG, making it a versatile approach for visualising a range of genomic comparison data. BRIG is readily accessible to any user, as it assumes no specialist computational knowledge and will perform all required file parsing and BLAST comparisons automatically. There is a clear need for a user

  12. Long term pavement performance directive : annual profiler-dipstick comparisons

    DOT National Transportation Integrated Search

    1996-11-25

    The objective of this directive is to initiate a formal program for Profiler - Dipstick comparisons. These comparison tests should be performed as a minimum, on an annual basis, or within 90 days after major repairs to any of the LTPP profile measure...

  13. Unpacking symbolic number comparison and its relation with arithmetic in adults.

    PubMed

    Sasanguie, Delphine; Lyons, Ian M; De Smedt, Bert; Reynvoet, Bert

    2017-08-01

    Symbolic number - or digit - comparison has been a central tool in the domain of numerical cognition for decades. More recently, individual differences in performance on this task have been shown to robustly relate to individual differences in more complex math processing - a result that has been replicated across many different age groups. In this study, we 'unpack' the underlying components of digit comparison (i.e. digit identification, digit to number-word matching, digit ordering and general comparison) in a sample of adults. In a first experiment, we showed that digit comparison performance was most strongly related to digit ordering ability - i.e., the ability to judge whether symbolic numbers are in numerical order. Furthermore, path analyses indicated that the relation between digit comparison and arithmetic was partly mediated by digit ordering and fully mediated when non-numerical (letter) ordering was also entered into the model. In a second experiment, we examined whether a general order working memory component could account for the relation between digit comparison and arithmetic. It could not. Instead, results were more consistent with the notion that fluent access and activation of long-term stored associations between numbers explains the relation between arithmetic and both digit comparison and digit ordering tasks. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Multivariate normative comparisons using an aggregated database

    PubMed Central

    Murre, Jaap M. J.; Huizenga, Hilde M.

    2017-01-01

    In multivariate normative comparisons, a patient’s profile of test scores is compared to those in a normative sample. Recently, it has been shown that these multivariate normative comparisons enhance the sensitivity of neuropsychological assessment. However, multivariate normative comparisons require multivariate normative data, which are often unavailable. In this paper, we show how a multivariate normative database can be constructed by combining healthy control group data from published neuropsychological studies. We show that three issues should be addressed to construct a multivariate normative database. First, the database may have a multilevel structure, with participants nested within studies. Second, not all tests are administered in every study, so many data may be missing. Third, a patient should be compared to controls of similar age, gender and educational background rather than to the entire normative sample. To address these issues, we propose a multilevel approach for multivariate normative comparisons that accounts for missing data and includes covariates for age, gender and educational background. Simulations show that this approach controls the number of false positives and has high sensitivity to detect genuine deviations from the norm. An empirical example is provided. Implications for other domains than neuropsychology are also discussed. To facilitate broader adoption of these methods, we provide code implementing the entire analysis in the open source software package R. PMID:28267796

  15. Final report on EURAMET.QM-S6/1195: Bilateral comparison of liquefied hydrocarbon mixtures in constant pressure (piston) cylinders

    NASA Astrophysics Data System (ADS)

    Brown, Andrew S.; Downey, Michael L.; Milton, Martin J. T.; van der Veen, Adriaan M. H.; Zalewska, Ewelina T.; Li, Jianrong

    2013-01-01

    Traceable liquid hydrocarbon mixtures are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas) and LNG (liquefied natural gas), thus meeting the needs of an increasingly large European industrial market. The development of traceable liquid hydrocarbon standards by National Measurement Institutes (NMIs) was still at a relatively early stage at the time this comparison was proposed in 2011. NPL and VSL, who were the only NMIs active in this area, had developed methods for the preparation and analysis of such standards in constant pressure (piston) cylinders, but neither laboratory had Calibration and Measurement Capabilities (CMCs) for these mixtures. This report presents the results of EURAMET 1195, the first comparison of liquid hydrocarbon mixtures between NMIs, which assessed the preparation and analytical capabilities of NPL and VSL for these mixtures. The comparison operated between August 2011 and January 2012. Each laboratory prepared a liquid hydrocarbon standard with nominally the same composition and these standards were exchanged for analysis. The results of the comparison show a good agreement between the laboratories' results and the comparison reference values for the six components with amount fractions greater than 1.0 cmol/mol (propane, propene, iso-butene, n-butane, iso-butane and 1-butene). Measurement of the three components with lower amount fractions (1,3-butadiene, iso-pentane and n-pentane) proved more challenging. In all but one case, the differences from the comparison reference values for these three components were greater than the expanded measurement uncertainty. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual

  16. The Influence of Social Comparison on Visual Representation of One's Face

    PubMed Central

    Zell, Ethan; Balcetis, Emily

    2012-01-01

    Can the effects of social comparison extend beyond explicit evaluation to visual self-representation—a perceptual stimulus that is objectively verifiable, unambiguous, and frequently updated? We morphed images of participants' faces with attractive and unattractive references. With access to a mirror, participants selected the morphed image they perceived as depicting their face. Participants who engaged in upward comparison with relevant attractive targets selected a less attractive morph compared to participants exposed to control images (Study 1). After downward comparison with relevant unattractive targets compared to control images, participants selected a more attractive morph (Study 2). Biased representations were not the products of cognitive accessibility of beauty constructs; comparisons did not influence representations of strangers' faces (Study 3). We discuss implications for vision, social comparison, and body image. PMID:22662124

  17. The Mediating Roles of Upward Social Comparison and Self-esteem and the Moderating Role of Social Comparison Orientation in the Association between Social Networking Site Usage and Subjective Well-Being

    PubMed Central

    Wang, Jin-Liang; Wang, Hai-Zhen; Gaskin, James; Hawk, Skyler

    2017-01-01

    The increased pervasiveness of social media use has raised questions about potential effects on users’ subjective well-being, with studies reaching contrasting conclusions. To reconcile these discrepancies and shed new light on this phenomenon, the current study examined: (1) whether upward social comparison and self-esteem mediate the association between social networking site (SNS) usage and users’ subjective well-being, and (2) whether the association between SNS usage and upward social comparison is moderated by users’ social comparison orientation. Data from 696 participants were collected. Structural equation modeling revealed that upward social comparison and self-esteem mediated the relationship between SNS usage and users’ subjective well-being. We found that social comparison orientation moderated the association between passive SNS usage and users’ upward social comparison. Specifically, social comparison orientation strengthened the association between passive SNS usage and upward social comparison. The results might suggest a process through which passive SNS usage is related to subjective well-being, and identify a context under which these associations may differ. PMID:28553256

  18. Psychometric properties of the Social Comparison Motives Scale.

    PubMed

    Tigges, Beth Baldwin

    2009-01-01

    This article describes the 19-item Social Comparison Motive Scale [SCMS], a measure of adolescents' motives for social comparison related to pregnancy. Dimensions and items were developed based on adolescent focus groups. The instrument was reviewed for content validity, pilot tested, and administered to 431 adolescents aged 14-18 years. Principal axis factor analysis with oblique rotation supported five dimensions. Convergent and discriminant validity were demonstrated by moderate correlations (r = .50) between the SCMS and the Iowa-Netherlands Comparison Orientation Measure and low correlations (r = .15) between the SCMS and the Rosenberg Self-Esteem Scale. Cronbach's alphas were .91 overall and .71 to .85 for the subscales. The SCMS demonstrated reliability and validity as a measure of adolescents' motives for comparing themselves with others about pregnancy.

  19. Comparisons and Evaluation of Hall Thruster Models

    DTIC Science & Technology

    2002-03-20

    COVERED (FROM - TO) 20-04-2001 to 20-04-2002 4. TITLE AND SUBTITLE comparisons and Evaluation of Hall Thruster Models Unclassified 5a. CONTRACT NUMBER...TITLE AND SUBTITLE Comparisons and Evaluation of Hall Thruster Models 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5d. TASK NUMBER 6. AUTHOR(S...evaluation of Hall thruster models G. J. M. Hagelaar, J. Bareilles, L. Garrigues, and J.-P. Boeuf CPAT, Bâtiment 3R2, Université Paul Sabatier 118 Route

  20. Upward and Downward: Social Comparison Processing of Thin Idealized Media Images

    ERIC Educational Resources Information Center

    Tiggemann, Marika; Polivy, Janet

    2010-01-01

    The present study aimed to investigate the role of social comparison processing in women's responses to thin idealized images. In particular, it was predicted that comparison with the images on the basis of appearance would lead to more negative outcomes than comparison on the basis of intelligence. A sample of 114 women viewed fashion magazine…

  1. webPIPSA: a web server for the comparison of protein interaction properties

    PubMed Central

    Richter, Stefan; Wenzel, Anne; Stein, Matthias; Gabdoulline, Razif R.; Wade, Rebecca C.

    2008-01-01

    Protein molecular interaction fields are key determinants of protein functionality. PIPSA (Protein Interaction Property Similarity Analysis) is a procedure to compare and analyze protein molecular interaction fields, such as the electrostatic potential. PIPSA may assist in protein functional assignment, classification of proteins, the comparison of binding properties and the estimation of enzyme kinetic parameters. webPIPSA is a web server that enables the use of PIPSA to compare and analyze protein electrostatic potentials. While PIPSA can be run with downloadable software (see http://projects.eml.org/mcm/software/pipsa), webPIPSA extends and simplifies a PIPSA run. This allows non-expert users to perform PIPSA for their protein datasets. With input protein coordinates, the superposition of protein structures, as well as the computation and analysis of electrostatic potentials, is automated. The results are provided as electrostatic similarity matrices from an all-pairwise comparison of the proteins which can be subjected to clustering and visualized as epograms (tree-like diagrams showing electrostatic potential differences) or heat maps. webPIPSA is freely available at: http://pipsa.eml.org. PMID:18420653

  2. A state comparison amplifier with feed forward state correction

    NASA Astrophysics Data System (ADS)

    Mazzarella, Luca; Donaldson, Ross; Collins, Robert; Zanforlin, Ugo; Buller, Gerald; Jeffers, John

    2017-04-01

    The Quantum State Comparison AMPlifier (SCAMP) is a probabilistic amplifier that works for known sets of coherent states. The input state is mixed with a guess state at a beam splitter and one of the output ports is coupled to a detector. The other output contains the amplified state, which is accepted on the condition that no counts are recorded. The system uses only classical resources and has been shown to achieve high gain and repetition rate. However the output fidelity is not high enough for most quantum communication purposes. Here we show how the success probability and fidelity are enhanced by repeated comparison stages, conditioning later state choices on the outcomes of earlier detections. A detector firing at an early stage means that a guess is wrong. This knowledge allows us to correct the state perfectly. The system requires fast-switching between different input states, but still requires only classical resources. Figures of merit compare favourably with other schemes, most notably the probability-fidelity product is higher than for unambiguous state discrimination. Due to its simplicity, the system is a candidate to counteract quantum signal degradation in a lossy fibre or as a quantum receiver to improve the key rate of continuous variable quantum communication. The work was supported by the QComm Project of the UK Engineering and Physical Sciences Research Council (EP/M013472/1).

  3. Role and Evaluation of Interlaboratory Comparison Results in Laboratory Accreditation

    NASA Astrophysics Data System (ADS)

    Bode, P.

    2008-08-01

    Participation in interlaboratory comparisons provides laboratories an opportunity for independent assessment of their analytical performance, both in absolute way and in comparison with those by other techniques. However, such comparisons are hindered by differences in the way laboratories participate, e.g. at best measurement capability or under routine conditions. Neutron activation analysis laboratories, determining total mass fractions, often see themselves classified as `outliers' since the majority of other participants employ techniques with incomplete digestion methods. These considerations are discussed in relation to the way results from interlaboratory comparisons are evaluated by accreditation bodies following the requirements of Clause 5.9.1 of the ISO/IEC 17025:2005. The discussion and conclusions come largely forth from experiences in the author's own laboratory.

  4. [Development of an Excel spreadsheet for meta-analysis of indirect and mixed treatment comparisons].

    PubMed

    Tobías, Aurelio; Catalá-López, Ferrán; Roqué, Marta

    2014-01-01

    Meta-analyses in clinical research usually aimed to evaluate treatment efficacy and safety in direct comparison with a unique comparator. Indirect comparisons, using the Bucher's method, can summarize primary data when information from direct comparisons is limited or nonexistent. Mixed comparisons allow combining estimates from direct and indirect comparisons, increasing statistical power. There is a need for simple applications for meta-analysis of indirect and mixed comparisons. These can easily be conducted using a Microsoft Office Excel spreadsheet. We developed a spreadsheet for indirect and mixed effects comparisons of friendly use for clinical researchers interested in systematic reviews, but non-familiarized with the use of more advanced statistical packages. The use of the proposed Excel spreadsheet for indirect and mixed comparisons can be of great use in clinical epidemiology to extend the knowledge provided by traditional meta-analysis when evidence from direct comparisons is limited or nonexistent.

  5. Cross-Disciplinary Network Comparison: Matchmaking Between Hairballs

    PubMed Central

    Yan, Koon-Kiu; Wang, Daifeng; Sethi, Anurag; Muir, Paul; Kitchen, Robert; Cheng, Chao; Gerstein, Mark

    2016-01-01

    Biological systems are complex. In particular, the interactions between molecular components often form dense networks that, more often than not, are criticized for being inscrutable ‘hairballs’. We argue that one way of untangling these hairballs is through cross-disciplinary network comparison—leveraging advances in other disciplines to obtain new biological insights. In some cases, such comparisons enable the direct transfer of mathematical formalism between disciplines, precisely describing the abstract associations between entities and allowing us to apply a variety of sophisticated formalisms to biology. In cases where the detailed structure of the network does not permit the transfer of complete formalisms between disciplines, comparison of mechanistic interactions in systems for which we have significant day-to-day experience can provide analogies for interpreting relatively more abstruse biological networks. Here, we illustrate how these comparisons benefit the field with a few specific examples related to network growth, organizational hierarchies, and the evolution of adaptive systems. PMID:27047991

  6. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Fall 2013 International Comparisons

    ERIC Educational Resources Information Center

    Northwest Evaluation Association, 2014

    2014-01-01

    This Fall report is an aggregated statistical analysis of Measures of Academic Progress® (MAP®) data from international schools. The report provides a consistent means of comparisons of specific sub-groups by subject and grade, which allows partners to compare their MAP® results with other schools within their region or membership organization.…

  8. Final report on regional supplementary comparison SIM.M.FF-S5: Volume of liquids at 50 mL

    NASA Astrophysics Data System (ADS)

    Morales, Abed; Malta, Dalni; Kornblit, Fernando; Ramírez, Ruben R.; Arias, Roberto; Trujillo, Sonia

    2012-01-01

    A regional supplementary comparison for the volume of liquid at 50 mL was conducted during October 2009 to June 2010 between the SIM members CENAM, INTI, INMETRO, INDECOPI and INTN. The transfer standard consisted of two 50 mL glass pycnometers, of the Gay Lussac type. CENAM acted as the pilot, collected the measurement results, analyzed the data and produced the comparison report. The median of all participants' results was used to calculate the regional comparison reference value because the result for one of the two pycnometers in one laboratory failed the chi-squared test at the 0.05 probability level. The measurements reported by the participants show an excellent overlap in four out of the five NMIs (-34×10-6 < Di < 29×10-6). The degree of equivalence obtained herein will be taken into account for the preparation of calibration and measurement capabilities claims from the participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Item Response Modeling of Paired Comparison and Ranking Data

    ERIC Educational Resources Information Center

    Maydeu-Olivares, Alberto; Brown, Anna

    2010-01-01

    The comparative format used in ranking and paired comparisons tasks can significantly reduce the impact of uniform response biases typically associated with rating scales. Thurstone's (1927, 1931) model provides a powerful framework for modeling comparative data such as paired comparisons and rankings. Although Thurstonian models are generally…

  10. Visualizing the Impact of Art: An Update and Comparison of Current Psychological Models of Art Experience

    PubMed Central

    Pelowski, Matthew; Markey, Patrick S.; Lauring, Jon O.; Leder, Helmut

    2016-01-01

    The last decade has witnessed a renaissance of empirical and psychological approaches to art study, especially regarding cognitive models of art processing experience. This new emphasis on modeling has often become the basis for our theoretical understanding of human interaction with art. Models also often define areas of focus and hypotheses for new empirical research, and are increasingly important for connecting psychological theory to discussions of the brain. However, models are often made by different researchers, with quite different emphases or visual styles. Inputs and psychological outcomes may be differently considered, or can be under-reported with regards to key functional components. Thus, we may lose the major theoretical improvements and ability for comparison that can be had with models. To begin addressing this, this paper presents a theoretical assessment, comparison, and new articulation of a selection of key contemporary cognitive or information-processing-based approaches detailing the mechanisms underlying the viewing of art. We review six major models in contemporary psychological aesthetics. We in turn present redesigns of these models using a unified visual form, in some cases making additions or creating new models where none had previously existed. We also frame these approaches in respect to their targeted outputs (e.g., emotion, appraisal, physiological reaction) and their strengths within a more general framework of early, intermediate, and later processing stages. This is used as a basis for general comparison and discussion of implications and future directions for modeling, and for theoretically understanding our engagement with visual art. PMID:27199697

  11. Visualizing the Impact of Art: An Update and Comparison of Current Psychological Models of Art Experience.

    PubMed

    Pelowski, Matthew; Markey, Patrick S; Lauring, Jon O; Leder, Helmut

    2016-01-01

    The last decade has witnessed a renaissance of empirical and psychological approaches to art study, especially regarding cognitive models of art processing experience. This new emphasis on modeling has often become the basis for our theoretical understanding of human interaction with art. Models also often define areas of focus and hypotheses for new empirical research, and are increasingly important for connecting psychological theory to discussions of the brain. However, models are often made by different researchers, with quite different emphases or visual styles. Inputs and psychological outcomes may be differently considered, or can be under-reported with regards to key functional components. Thus, we may lose the major theoretical improvements and ability for comparison that can be had with models. To begin addressing this, this paper presents a theoretical assessment, comparison, and new articulation of a selection of key contemporary cognitive or information-processing-based approaches detailing the mechanisms underlying the viewing of art. We review six major models in contemporary psychological aesthetics. We in turn present redesigns of these models using a unified visual form, in some cases making additions or creating new models where none had previously existed. We also frame these approaches in respect to their targeted outputs (e.g., emotion, appraisal, physiological reaction) and their strengths within a more general framework of early, intermediate, and later processing stages. This is used as a basis for general comparison and discussion of implications and future directions for modeling, and for theoretically understanding our engagement with visual art.

  12. [Pitfalls in international comparisons of health data and indices].

    PubMed

    Rotstein, Z; Shani, M

    1991-05-01

    Comparison of published data and health indices from different countries with different health systems is subject to many pitfalls. Comparison of national expenditure for health care based on purchasing power of the currency may be misleading if the purchasing power of the health services is ignored. Comparisons may also be misleading if they ignore national geographic and demographic structures. Government and health authorities often quote different sets of data and use different terminology and definitions. This article stresses the disparity in the definition of medical manpower and points out differences relating to ratios of manpower to population and to per capita spending. Also addressed is the importance of the qualitative and value aspects of health systems not usually involved in comparison of international health indices. In conclusion, safety measures and precautions such as choosing the right index for the right purpose, adjustment of indices to the purchasing power parity of health, demographics, etc., should be used when conducting health care analyses.

  13. Comparison of Fixed Point Realisations between Inmetro and PTB

    NASA Astrophysics Data System (ADS)

    Santiago, J. F. N.; Petkovic, S. G.; Teixeira, R. N.; Noatsch, U.; Thiele-Krivoj, B.

    2003-09-01

    An interlaboratory comparison in the temperature range between -190 °C and 420 °C was organised between the National Institute of Quality, Normalisation and Industrial Quality (Inmetro), Brazil, and the Physikalisch Technische Bundesanstalt (PTB), Germany. This comparison followed the same protocol as the EUROMET project 552 comparison and was carried out in the years 2001-2002. A standard platinum resistance thermometer (SPRT) of 25 Ω was calibrated at the temperature fixed points of Ar, Hg, the triple point of water (TWP), Ga, In, Sn and Zn, with at least three realisations of each fixed point at both institutes. The uncertainty evaluation is given by Inmetro and some differences in the calibration procedures or in the measuring instruments used are described. The agreement between the results of laboratories was not in all cases within the combined uncertainties. Results of other comparisons are presented, which give additional information on the equivalence of the realised temperature scales.

  14. Social Comparison: The End of a Theory and the Emergence of a Field

    ERIC Educational Resources Information Center

    Buunk, Abraham P.; Gibbons, Frederick X.

    2007-01-01

    The past and current states of research on social comparison are reviewed with regard to a series of major theoretical developments that have occurred in the past 5 decades. These are, in chronological order: (1) classic social comparison theory, (2) fear-affiliation theory, (3) downward comparison theory, (4) social comparison as social…

  15. A comparison of self-oscillating phonation models

    NASA Astrophysics Data System (ADS)

    McPhail, Michael; Campo, Elizabeth; Walters, Gage; Krane, Michael

    2017-11-01

    This talk presents a comparison of self-oscillating models of phonation. The goal is to assess how well synthetic rubber vocal folds reproduce the gross behavior of phonation. Data from molded rubber folds and a variety of excised mammalian larynges were collected from the literature and from the authors' physical model. Gross trends are discussed and a simple scaling is presented that appears to collapse these data. Finally, comparisons between molded rubber folds and excised larynges are highlighted. Acknowledge support from NIH DC R01005642-11.

  16. Changes in latent fingerprint examiners' markup between analysis and comparison.

    PubMed

    Ulery, Bradford T; Hicklin, R Austin; Roberts, Maria Antonia; Buscaglia, JoAnn

    2015-02-01

    After the initial analysis of a latent print, an examiner will sometimes revise the assessment during comparison with an exemplar. Changes between analysis and comparison may indicate that the initial analysis of the latent was inadequate, or that confirmation bias may have affected the comparison. 170 volunteer latent print examiners, each randomly assigned 22 pairs of prints from a pool of 320 total pairs, provided detailed markup documenting their interpretations of the prints and the bases for their comparison conclusions. We describe changes in value assessments and markup of features and clarity. When examiners individualized, they almost always added or deleted minutiae (90.3% of individualizations); every examiner revised at least some markups. For inconclusive and exclusion determinations, changes were less common, and features were added more frequently when the image pair was mated (same source). Even when individualizations were based on eight or fewer corresponding minutiae, in most cases some of those minutiae had been added during comparison. One erroneous individualization was observed: the markup changes were notably extreme, and almost all of the corresponding minutiae had been added during comparison. Latents assessed to be of value for exclusion only (VEO) during analysis were often individualized when compared to a mated exemplar (26%); in our previous work, where examiners were not required to provide markup of features, VEO individualizations were much less common (1.8%). Published by Elsevier Ireland Ltd.

  17. ClinicalKey: a point-of-care search engine.

    PubMed

    Vardell, Emily

    2013-01-01

    ClinicalKey is a new point-of-care resource for health care professionals. Through controlled vocabulary, ClinicalKey offers a cross section of resources on diseases and procedures, from journals to e-books and practice guidelines to patient education. A sample search was conducted to demonstrate the features of the database, and a comparison with similar tools is presented.

  18. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  19. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  20. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  1. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  2. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  3. Peer influence on students' estimates of performance: social comparison in clinical rotations.

    PubMed

    Raat, A N Janet; Kuks, Jan B M; van Hell, E Ally; Cohen-Schotanus, Janke

    2013-02-01

    During clinical rotations, students move from one clinical situation to another. Questions exist about students' strategies for coping with these transitions. These strategies may include a process of social comparison because in this context it offers the student an opportunity to estimate his or her abilities to master a novel rotation. These estimates are relevant for learning and performance because they are related to self-efficacy. We investigated whether student estimates of their own future performance are influenced by the performance level and gender of the peer with whom the student compares him- or herself. We designed an experimental study in which participating students (n = 321) were divided into groups assigned to 12 different conditions. Each condition entailed a written comparison situation in which a peer student had completed the rotation the participant was required to undertake next. Differences between conditions were determined by the performance level (worse, similar or better) and gender of the comparison peer. The overall grade achieved by the comparison peer remained the same in all conditions. We asked participants to estimate their own future performance in that novel rotation. Differences between their estimates were analysed using analysis of variance (ANOVA). Students' estimates of their future performance were highest when the comparison peer was presented as performing less well and lowest when the comparison peer was presented as performing better (p < 0.001). Estimates of male and female students in same-gender comparison conditions did not differ. In two of three opposite-gender conditions, male students' estimates were higher than those of females (p < 0.001 and p < 0.05, respectively). Social comparison influences students' estimates of their future performance in a novel rotation. The effect depends on the performance level and gender of the comparison peer. This indicates that comparisons against particular peers may

  4. Policy Claims and Problem Frames: A Cross-Case Comparison of Evidence-Based Policy in an Australian Context

    ERIC Educational Resources Information Center

    van Toorn, Georgia; Dowse, Leanne

    2016-01-01

    This paper explores the signification of evidence-based policy as a new policy-making paradigm in Australia through a cross-case comparison of the role of evidence in two key areas: child protection and illicit drug policy. Although evidence makes certain courses of action appear valid and credible, quality evidence is not necessarily the critical…

  5. MODIS comparisons with northeastern Pacific in situ stratocumulus microphysics

    NASA Astrophysics Data System (ADS)

    Noble, Stephen R.; Hudson, James G.

    2015-08-01

    Vertical sounding measurements within stratocumuli during two aircraft field campaigns, Marine Stratus/stratocumulus Experiment (MASE) and Physics of Stratocumulus Top (POST), are used to validate Moderate Resolution Imaging Spectroradiometer (MODIS) cloud optical thickness (COT), cloud liquid water path (LWP), and cloud effective radius (re). In situ COT, LWP, and re were calculated using 5 m vertically averaged droplet probe measurements of complete vertical cloud penetrations. MODIS COT, LWP, and re 1 km pixels were averaged along these penetrations. COT comparisons in POST showed strong correlations and a near 1:1 relationship. In MASE, comparisons showed strong correlations; however, MODIS COT exceeded in situ COT, likely due to larger temporal differences between MODIS and in situ measurements. LWP comparisons between two cloud probes show good agreement for POST but not MASE, giving confidence to POST data. Both projects provided strong LWP correlations but MODIS exceeded in situ by 14-36%. MODIS in situ re correlations were strong, but MODIS 2.1 µm re exceeded in situ re, which contributed to LWP bias; in POST, MODIS re was 20-30% greater than in situ re. Maximum in situ re near cloud top showed comparisons nearer 1:1. Other MODIS re bands (3.7 µm and 1.6 µm) showed similar comparisons. Temporal differences between MODIS and in situ measurements, airplane speed differences, and cloud probe artifacts were likely causes of weaker MASE correlations. POST COT comparison was best for temporal differences under 20 min. POST data validate MODIS COT but it also implies a positive MODIS re bias that propagates to LWP while still capturing variability.

  6. BEACON: automated tool for Bacterial GEnome Annotation ComparisON.

    PubMed

    Kalkatawi, Manal; Alam, Intikhab; Bajic, Vladimir B

    2015-08-18

    Genome annotation is one way of summarizing the existing knowledge about genomic characteristics of an organism. There has been an increased interest during the last several decades in computer-based structural and functional genome annotation. Many methods for this purpose have been developed for eukaryotes and prokaryotes. Our study focuses on comparison of functional annotations of prokaryotic genomes. To the best of our knowledge there is no fully automated system for detailed comparison of functional genome annotations generated by different annotation methods (AMs). The presence of many AMs and development of new ones introduce needs to: a/ compare different annotations for a single genome, and b/ generate annotation by combining individual ones. To address these issues we developed an Automated Tool for Bacterial GEnome Annotation ComparisON (BEACON) that benefits both AM developers and annotation analysers. BEACON provides detailed comparison of gene function annotations of prokaryotic genomes obtained by different AMs and generates extended annotations through combination of individual ones. For the illustration of BEACON's utility, we provide a comparison analysis of multiple different annotations generated for four genomes and show on these examples that the extended annotation can increase the number of genes annotated by putative functions up to 27%, while the number of genes without any function assignment is reduced. We developed BEACON, a fast tool for an automated and a systematic comparison of different annotations of single genomes. The extended annotation assigns putative functions to many genes with unknown functions. BEACON is available under GNU General Public License version 3.0 and is accessible at: http://www.cbrc.kaust.edu.sa/BEACON/ .

  7. Comparison of Artificial Compressibility Methods

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin; Housman, Jeffrey; Kwak, Dochan

    2004-01-01

    Various artificial compressibility methods for calculating the three-dimensional incompressible Navier-Stokes equations are compared. Each method is described and numerical solutions to test problems are conducted. A comparison based on convergence behavior, accuracy, and robustness is given.

  8. Thinspiration: Self-Improvement Versus Self-Evaluation Social Comparisons with Thin-Ideal Media Portrayals.

    PubMed

    Knobloch-Westerwick, Silvia

    2015-01-01

    Much research has demonstrated negative impacts of idealized-body imagery exposure on body satisfaction. Yet, paradoxically, media with such imagery attract mass audiences. Few studies showed women's body satisfaction increased due to thin-ideal exposure. The kind of social comparison women engage in (self-evaluation vs. self-improvement) may explain these inconsistent findings and the paradoxical attraction to thin-ideal messages. Across 5 days, thin-ideal messages were presented to 51 women; self-evaluation and self-improvement social comparisons as well as body satisfaction were measured each day. A linear positive change in body satisfaction emerged. Greater self-improvement social comparisons increased this change, whereas greater self-evaluation social comparisons reduced it. Extent of both social comparison types changed during the prolonged exposure. A greater tendency to compare one's body with others' improved body satisfaction through self-improvement social comparisons and fostered weight-loss behaviors through self-evaluation social comparisons.

  9. Patients' perspectives on social and goal-based comparisons regarding their diabetes health status.

    PubMed

    Martinez, William; Wallston, Kenneth A; Schlundt, David G; Hickson, Gerald B; Bonnet, Kemberlee R; Trochez, Ricardo J; Elasy, Tom A

    2018-01-01

    Social comparisons (ie, self-evaluation in comparison with others) influence patients' perspectives of their disease and may impact motivation and health behavior; however, little is known about patients' perspectives toward receiving such information in a clinical context (eg, from their doctor's office or health system). This study aims to understand patients' perspectives and anticipated responses to receiving social comparison information regarding measures of their diabetes-related health status (eg, A1C) and how receiving such information would compare with goal-based comparisons (ie, self-evaluation in comparison with goal). We conducted semistructured interviews with 25 patients with type 2 diabetes mellitus (T2DM) regarding social and goal-based comparisons involving their diabetes health status and qualitatively analyzed interviews for themes. We identified seven major themes: self-relevance, motivation, self-concept, emotions, information seeking, medical care, and self-care. Participants commonly anticipated increased motivation and improved health behaviors in response to both social and goal-based comparisons. Subthemes unique to social comparisons included belief that this information would be motivating by engaging some patients' competitiveness, perception that this information was more 'personalized' than comparisons with a standard goal (eg, A1C<7), and desire to learn from individuals similar to oneself who were doing better. Our findings provide significant insights into the anticipated response of patients with T2DM to receiving social and goal-based comparison information regarding their diabetes health status. Providing patients with diabetes with social and goal-based comparison information may affect motivation, mood, and self-concept in ways that may improve or sustain diabetes self-care behaviors for some patients.

  10. A quantitative comparison of corrective and perfective maintenance

    NASA Technical Reports Server (NTRS)

    Henry, Joel; Cain, James

    1994-01-01

    This paper presents a quantitative comparison of corrective and perfective software maintenance activities. The comparison utilizes basic data collected throughout the maintenance process. The data collected are extensive and allow the impact of both types of maintenance to be quantitatively evaluated and compared. Basic statistical techniques test relationships between and among process and product data. The results show interesting similarities and important differences in both process and product characteristics.

  11. Differential Social Comparison Processes in Women with and without Eating Disorder Symptoms

    ERIC Educational Resources Information Center

    Corning, Alexandra F.; Krumm, Angela J.; Smitham, Lora A.

    2006-01-01

    On the basis of predictions from social comparison theory (L. Festinger, 1954) and informed by findings from the social comparison and eating disorder literatures, hypotheses were tested regarding the social comparison behaviors of women with eating disorder symptoms and their asymptomatic peers. Results indicated differentiating social-cognitive…

  12. Analysis of Survivor Benefit Plan - Acceptance and Comparison with Private Sector

    DTIC Science & Technology

    1989-01-01

    I COPY AIU WAR COLLEGE ,.SEARCH REPORT ,YSIS OF SURVIVOR BENEFIT PLAN-__CCEPTANCE ’-U AND COMPARISON WITH PRIVATE SECTOR LIEUENNT COLONEL JOHN R...AAA AIR WAR COLLEGE AIR UNIVERSITY ANALYSIS OF SURVIVOR BENEFIT PLAN--ACCEPTANCE AND COMPARISON WITH PRIVATE SECTOR by John R. Adams Lieutenant...Survivor Benefit Plan (SBP)--Acceptance and Comparison With Private Sector . AUTHORS: John R. Adams, Lieutenant Colonel, USAF; Daniel 3. Kohn

  13. Comparison of two target classification techniques

    NASA Astrophysics Data System (ADS)

    Chen, J. S.; Walton, E. K.

    1986-01-01

    Radar target classification techniques based on backscatter measurements in the resonance region (1.0-20.0 MHz) are discussed. Attention is given to two novel methods currently being tested at the radar range of Ohio State University. The methods include: (1) the nearest neighbor (NN) algorithm for determining the radar cross section (RCS) magnitude and range corrected phase at various operating frequencies; and (2) an inverse Fourier transformation of the complex multifrequency radar returns of the time domain, followed by cross correlation analysis. Comparisons are made of the performance of the two techniques as a function of signal-to-error noise ratio for different types of processing. The results of the comparison are discussed in detail.

  14. The limits of protein sequence comparison?

    PubMed Central

    Pearson, William R; Sierk, Michael L

    2010-01-01

    Modern sequence alignment algorithms are used routinely to identify homologous proteins, proteins that share a common ancestor. Homologous proteins always share similar structures and often have similar functions. Over the past 20 years, sequence comparison has become both more sensitive, largely because of profile-based methods, and more reliable, because of more accurate statistical estimates. As sequence and structure databases become larger, and comparison methods become more powerful, reliable statistical estimates will become even more important for distinguishing similarities that are due to homology from those that are due to analogy (convergence). The newest sequence alignment methods are more sensitive than older methods, but more accurate statistical estimates are needed for their full power to be realized. PMID:15919194

  15. Planned Comparisons as Better Alternatives to ANOVA Omnibus Tests.

    ERIC Educational Resources Information Center

    Benton, Roberta L.

    Analyses of data are presented to illustrate the advantages of using a priori or planned comparisons rather than omnibus analysis of variance (ANOVA) tests followed by post hoc or posteriori testing. The two types of planned comparisons considered are planned orthogonal non-trend coding contrasts and orthogonal polynomial or trend contrast coding.…

  16. Site-index comparisons for tree species in northern Minnesota.

    Treesearch

    Willard H. Carmean; Alexander Vasilevsky

    1971-01-01

    Presents site-index comparisons for the following forest species in northern Minnesota: quaking aspen, paper birch, basswood, red oak, black ash, jack pine, red pine, white pine, white spruce, black spruce, balsam fir, white-cedar, and tamarack. Shows site-index relationships among these species by using site-index ratios and species-comparison graphs.

  17. Water vapour inter-comparison effort in the framework of the hydrological cycle in the mediterranean experiment - special observation period (hymex-sop1)

    NASA Astrophysics Data System (ADS)

    Summa, Donato; Di Girolamo, Paolo; Flamant, Cyrille; De Rosa, Benedetto; Cacciani, Marco; Stelitano, Dario

    2018-04-01

    Accurate measurements of the vertical profiles of water vapour are of paramount importance for most key areas of atmospheric sciences. A comprehensive inter-comparison between different remote sensing and in-situ sensors has been carried out in the frame work of the first Special Observing Period of the Hydrological cycle in the Mediterranean Experiment for the purpose of obtaining accurate error estimates for these sensors. The inter-comparison involves a ground-based Raman lidar (BASIL), an airborne DIAL (LEANDRE2), a microwave radiometer, radiosondes and aircraft in-situ sensors.

  18. First Interlaboratory Comparison on Calibration of Temperature-Controlled Enclosures in Turkey

    NASA Astrophysics Data System (ADS)

    Uytun, A.; Kalemci, M.

    2017-11-01

    The number of accredited laboratories in the field of calibration of temperature-controlled enclosures has been increasing in Turkey. One of the main criteria demonstrating the competence of a calibration laboratory is successful participation in interlaboratory comparisons. Therefore, TUBITAK UME Temperature Laboratory organized the first interlaboratory comparison on "Calibration of Temperature-Controlled Enclosures" in Turkey as a pilot laboratory between January and November, 2013. Forty accredited laboratories which provide routine calibration services to the industry in this field participated in the comparison. The standards used during the comparison was a climatic chamber for the measurements at -40 {°}C, -20 {°}C, 40 {°}C and 100 {°}C and an oven for the measurements at 200 {°}C. The protocol of the comparison was prepared considering guide EURAMET cg-20 and BS EN/IEC standards 600068-3-5 and 600068-3-11. During the comparison measurements, each participant had the liberty to choose the most convenient calibration points in terms of their accreditation scope among the values mentioned above and carried out on-site measurements at UME. The details and the results of this comparison are given in the paper. Determination of the statistical consistency of the results with the uncertainties given by the participants can be assessed by the method of En value assessment for each laboratory. En values for all measurement results based on the results of pilot and participating laboratories were calculated.

  19. Breaking the computational barriers of pairwise genome comparison.

    PubMed

    Torreno, Oscar; Trelles, Oswaldo

    2015-08-11

    Conventional pairwise sequence comparison software algorithms are being used to process much larger datasets than they were originally designed for. This can result in processing bottlenecks that limit software capabilities or prevent full use of the available hardware resources. Overcoming the barriers that limit the efficient computational analysis of large biological sequence datasets by retrofitting existing algorithms or by creating new applications represents a major challenge for the bioinformatics community. We have developed C libraries for pairwise sequence comparison within diverse architectures, ranging from commodity systems to high performance and cloud computing environments. Exhaustive tests were performed using different datasets of closely- and distantly-related sequences that span from small viral genomes to large mammalian chromosomes. The tests demonstrated that our solution is capable of generating high quality results with a linear-time response and controlled memory consumption, being comparable or faster than the current state-of-the-art methods. We have addressed the problem of pairwise and all-versus-all comparison of large sequences in general, greatly increasing the limits on input data size. The approach described here is based on a modular out-of-core strategy that uses secondary storage to avoid reaching memory limits during the identification of High-scoring Segment Pairs (HSPs) between the sequences under comparison. Software engineering concepts were applied to avoid intermediate result re-calculation, to minimise the performance impact of input/output (I/O) operations and to modularise the process, thus enhancing application flexibility and extendibility. Our computationally-efficient approach allows tasks such as the massive comparison of complete genomes, evolutionary event detection, the identification of conserved synteny blocks and inter-genome distance calculations to be performed more effectively.

  20. Arima model and exponential smoothing method: A comparison

    NASA Astrophysics Data System (ADS)

    Wan Ahmad, Wan Kamarul Ariffin; Ahmad, Sabri

    2013-04-01

    This study shows the comparison between Autoregressive Moving Average (ARIMA) model and Exponential Smoothing Method in making a prediction. The comparison is focused on the ability of both methods in making the forecasts with the different number of data sources and the different length of forecasting period. For this purpose, the data from The Price of Crude Palm Oil (RM/tonne), Exchange Rates of Ringgit Malaysia (RM) in comparison to Great Britain Pound (GBP) and also The Price of SMR 20 Rubber Type (cents/kg) with three different time series are used in the comparison process. Then, forecasting accuracy of each model is measured by examinethe prediction error that producedby using Mean Squared Error (MSE), Mean Absolute Percentage Error (MAPE), and Mean Absolute deviation (MAD). The study shows that the ARIMA model can produce a better prediction for the long-term forecasting with limited data sources, butcannot produce a better prediction for time series with a narrow range of one point to another as in the time series for Exchange Rates. On the contrary, Exponential Smoothing Method can produce a better forecasting for Exchange Rates that has a narrow range of one point to another for its time series, while itcannot produce a better prediction for a longer forecasting period.

  1. Sediment sorting along tidal sand waves: A comparison between field observations and theoretical predictions

    NASA Astrophysics Data System (ADS)

    Van Oyen, Tomas; Blondeaux, Paolo; Van den Eynde, Dries

    2013-07-01

    A site-by-site comparison between field observations and theoretical predictions of sediment sorting patterns along tidal sand waves is performed for ten locations in the North Sea. At each site, the observed grain size distribution along the bottom topography and the geometry of the bed forms is described in detail and the procedure used to obtain the model parameters is summarized. The model appears to accurately describe the wavelength of the observed sand waves for the majority of the locations; still providing a reliable estimate for the other sites. In addition, it is found that for seven out of the ten locations, the qualitative sorting process provided by the model agrees with the observed grain size distribution. A discussion of the site-by-site comparison is provided which, taking into account uncertainties in the field data, indicates that the model grasps the major part of the key processes controlling the phenomenon.

  2. Social comparison processes and catastrophising in fibromyalgia: A path analysis.

    PubMed

    Cabrera-Perona, V; Buunk, A P; Terol-Cantero, M C; Quiles-Marcos, Y; Martín-Aragón, M

    2017-06-01

    In addition to coping strategies, social comparison may play a role in illness adjustment. However, little is known about the role of contrast and identification in social comparison in adaptation to fibromyalgia. To evaluate through a path analysis in a sample of fibromyalgia patients, the association between identification and contrast in social comparison, catastrophising and specific health outcomes (fibromyalgia illness impact and psychological distress). 131 Spanish fibromyalgia outpatients (mean age: 50.15, SD = 11.1) filled out a questionnaire. We present a model that explained 33% of the variance in catastrophising by direct effects of more use of upward contrast and downward identification. In addition, 35% of fibromyalgia illness impact variance was explained by less upward identification, more upward contrast and more catastrophising and 42% of the variance in psychological distress by a direct effect of more use of upward contrast together with higher fibromyalgia illness impact. We suggest that intervention programmes with chronic pain and fibromyalgia patients should focus on enhancing the use of upward identification in social comparison, and on minimising the use of upward contrast and downward identification in social comparison.

  3. MODIS comparisons with northeastern Pacific in situ stratocumulus microphysics

    PubMed Central

    Noble, Stephen R.

    2015-01-01

    Abstract Vertical sounding measurements within stratocumuli during two aircraft field campaigns, Marine Stratus/stratocumulus Experiment (MASE) and Physics of Stratocumulus Top (POST), are used to validate Moderate Resolution Imaging Spectroradiometer (MODIS) cloud optical thickness (COT), cloud liquid water path (LWP), and cloud effective radius (r e). In situ COT, LWP, and r e were calculated using 5 m vertically averaged droplet probe measurements of complete vertical cloud penetrations. MODIS COT, LWP, and r e 1 km pixels were averaged along these penetrations. COT comparisons in POST showed strong correlations and a near 1:1 relationship. In MASE, comparisons showed strong correlations; however, MODIS COT exceeded in situ COT, likely due to larger temporal differences between MODIS and in situ measurements. LWP comparisons between two cloud probes show good agreement for POST but not MASE, giving confidence to POST data. Both projects provided strong LWP correlations but MODIS exceeded in situ by 14–36%. MODIS in situ r e correlations were strong, but MODIS 2.1 µm r e exceeded in situ r e, which contributed to LWP bias; in POST, MODIS r e was 20–30% greater than in situ r e. Maximum in situ r e near cloud top showed comparisons nearer 1:1. Other MODIS r e bands (3.7 µm and 1.6 µm) showed similar comparisons. Temporal differences between MODIS and in situ measurements, airplane speed differences, and cloud probe artifacts were likely causes of weaker MASE correlations. POST COT comparison was best for temporal differences under 20 min. POST data validate MODIS COT but it also implies a positive MODIS r e bias that propagates to LWP while still capturing variability. PMID:27708990

  4. MODIS comparisons with northeastern Pacific in situ stratocumulus microphysics

    DOE PAGES

    Noble, Stephen R.; Hudson, James G.

    2015-07-22

    Here, vertical sounding measurements within stratocumuli during two aircraft field campaigns, Marine Stratus/stratocumulus Experiment (MASE) and Physics of Stratocumulus Top (POST), are used to validate Moderate Resolution Imaging Spectroradiometer (MODIS) cloud optical thickness (COT), cloud liquid water path (LWP), and cloud effective radius (r e). In situ COT, LWP, and r e were calculated using 5 m vertically averaged droplet probe measurements of complete vertical cloud penetrations. MODIS COT, LWP, and r e 1 km pixels were averaged along these penetrations. COT comparisons in POST showed strong correlations and a near 1:1 relationship. In MASE, comparisons showed strong correlations; however,more » MODIS COT exceeded in situ COT, likely due to larger temporal differences between MODIS and in situ measurements. LWP comparisons between two cloud probes show good agreement for POST but not MASE, giving confidence to POST data. Both projects provided strong LWP correlations but MODIS exceeded in situ by 14–36%. MODIS in situ r e correlations were strong, but MODIS 2.1 µm r e exceeded in situ r e, which contributed to LWP bias; in POST, MODIS r e was 20–30% greater than in situ r e. Maximum in situ r e near cloud top showed comparisons nearer 1:1. Other MODIS r e bands (3.7 µm and 1.6 µm) showed similar comparisons. Temporal differences between MODIS and in situ measurements, airplane speed differences, and cloud probe artifacts were likely causes of weaker MASE correlations. POST COT comparison was best for temporal differences under 20 min. POST data validate MODIS COT but it also implies a positive MODIS r e bias that propagates to LWP while still capturing variability.« less

  5. Social Comparison Processes in an Organizational Context: New Directions

    ERIC Educational Resources Information Center

    Goodman, Paul S.; Haisley, Emily

    2007-01-01

    The goal of this article is to frame some new directions to social comparison research in organizational settings. Four themes are developed. First, we examine the role of organizational variables in shaping the basic sub processes in social comparison, such as the selection of referents. The second theme focuses on the meaning of level of…

  6. Using Paired Comparisons to Assess Maslow's Hierarchy of Needs.

    ERIC Educational Resources Information Center

    Strong, Lisa L.; Fiebert, Martin S.

    Past studies which have examined need levels have identified individuals as functioning at specific need levels without an adequate assessment of the intensity of each need or a clear comparison with other need levels. To address these issues, a self-report inventory using a modified paired comparison format was developed to assess need potencies…

  7. Development of Fraction Comparison Strategies: A Latent Transition Analysis

    ERIC Educational Resources Information Center

    Rinne, Luke F.; Ye, Ai; Jordan, Nancy C.

    2017-01-01

    The present study investigated the development of fraction comparison strategies through a longitudinal analysis of children's responses to a fraction comparison task in 4th through 6th grades (N = 394). Participants were asked to choose the larger value for 24 fraction pairs blocked by fraction type. Latent class analysis of performance over item…

  8. Continuous variable quantum key distribution: finite-key analysis of composable security against coherent attacks.

    PubMed

    Furrer, F; Franz, T; Berta, M; Leverrier, A; Scholz, V B; Tomamichel, M; Werner, R F

    2012-09-07

    We provide a security analysis for continuous variable quantum key distribution protocols based on the transmission of two-mode squeezed vacuum states measured via homodyne detection. We employ a version of the entropic uncertainty relation for smooth entropies to give a lower bound on the number of secret bits which can be extracted from a finite number of runs of the protocol. This bound is valid under general coherent attacks, and gives rise to keys which are composably secure. For comparison, we also give a lower bound valid under the assumption of collective attacks. For both scenarios, we find positive key rates using experimental parameters reachable today.

  9. Interactive comparison and remediation of collections of macromolecular structures.

    PubMed

    Moriarty, Nigel W; Liebschner, Dorothee; Klei, Herbert E; Echols, Nathaniel; Afonine, Pavel V; Headd, Jeffrey J; Poon, Billy K; Adams, Paul D

    2018-01-01

    Often similar structures need to be compared to reveal local differences throughout the entire model or between related copies within the model. Therefore, a program to compare multiple structures and enable correction any differences not supported by the density map was written within the Phenix framework (Adams et al., Acta Cryst 2010; D66:213-221). This program, called Structure Comparison, can also be used for structures with multiple copies of the same protein chain in the asymmetric unit, that is, as a result of non-crystallographic symmetry (NCS). Structure Comparison was designed to interface with Coot(Emsley et al., Acta Cryst 2010; D66:486-501) and PyMOL(DeLano, PyMOL 0.99; 2002) to facilitate comparison of large numbers of related structures. Structure Comparison analyzes collections of protein structures using several metrics, such as the rotamer conformation of equivalent residues, displays the results in tabular form and allows superimposed protein chains and density maps to be quickly inspected and edited (via the tools in Coot) for consistency, completeness and correctness. © 2017 The Protein Society.

  10. Cylinder expansion test and gas gun experiment comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrier, Danielle

    This is a summer internship presentation by the Hydro Working Group at Los Alamos National Laboratory (LANL) and goes into detail about their cylinder expansion test and gas gun experiment comparison. Specifically, the gas gun experiment is detailed along with applications, the cylinder expansion test is detailed along with applications, there is a comparison of the methods with pros and cons and limitations listed, the summer project is detailed, and future work is talked about.

  11. Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays.

    PubMed

    O'Brien, Michelle; Bueermann, Ludwig

    2009-01-01

    A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two NIST reference-class transfer ionization chamber standards. Results are presented for the reference radiation beam qualities in the range from 25 kV to 50 kV for low energy x rays, including the techniques used for mammography dose traceability. The tungsten generated reference radiation qualities, between 25 kV and 50 kV used for this comparison, are new to NIST; therefore this comparison will serve as the preliminary comparison for NIST and a verification of the primary standard correction factors. The mammography comparison will repeat two previously unpublished comparisons between PTB and NIST. The results show the standards to be in reasonable agreement within the standard uncertainty of the comparison of about 0.4 %.

  12. Satellite to Ground-based LIDAR Comparisons using MPLNET Data Products

    NASA Technical Reports Server (NTRS)

    Berkoff, T.A.; Belcher, L.; Campbell, J.; Spinhirne, J.; Welton, E. J.

    2007-01-01

    The Micro-Pulse Lidar Network (MPLNET) is a network of ground-based lidar systems that provide continuous long-term observations of aerosol and cloud properties at approximately 10 different locations around the globe. Each site in the network uses an elastic scattering lidar co-located with a sunphotometer to provide data products of aerosol optical physical properties. Data products from sites are available on a next-day basis from the MPLNET website. Expansion of the network is based on partnering with research groups interested in joining MPLNET. Results have contributed to a variety of studies including aerosol transport studies and satellite calibration and validation efforts. One of the key motivations for MPLNET is to contribute towards the calibration and validation of satellite-based lidars such as GLAS/ICESAT and CALIPSO. MPLNET is able to provide comparison to several of the key aerosol and cloud CALIPSO data products including: layer height and thickness, optical depth, backscatter and extinction profiles, and the extinction-to-backscatter ratio.

  13. Activity measurements of the radionuclides 18F and 64Cu for the NIST, USA in the ongoing comparisons BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Nonis, M.; Bergeron, D.; Cessna, J.; Fitzgerald, R.; Pibida, L.; Zimmerman, B.; Fenwick, A.; Ferreira, K.; Keightley, J.; Da Silva, I.

    2017-01-01

    In 2016, comparisons of activity measurements of 18F and 64Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for 64Cu. Ampoules containing about 27 kBq of 18F and 100 kBq of 64Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)β-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for 18F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. A comparison of five benchmarks

    NASA Technical Reports Server (NTRS)

    Huss, Janice E.; Pennline, James A.

    1987-01-01

    Five benchmark programs were obtained and run on the NASA Lewis CRAY X-MP/24. A comparison was made between the programs codes and between the methods for calculating performance figures. Several multitasking jobs were run to gain experience in how parallel performance is measured.

  15. Complex Molecules in the Laboratory - a Comparison of Chriped Pulse and Emission Spectroscopy

    NASA Astrophysics Data System (ADS)

    Hermanns, Marius; Wehres, Nadine; Maßen, Jakob; Schlemmer, Stephan

    2017-06-01

    Detecting molecules of astrophysical interest in the interstellar medium strongly relies on precise spectroscopic data from the laboratory. In recent years, the advancement of the chirped-pulse technique has added many more options available to choose from. The Cologne emission spectrometer is an additional path to molecular spectroscopy. It allows to record instantaneously broad band spectra with calibrated intensities. Here we present a comparison of both methods: The Cologne chirped-pulse spectrometer as well as the Cologne emission spectrometer both cover the frequency range of 75-110 GHz, consistent with the ALMA Band 3 receivers. High sensitive heterodyne receivers with very low noise temperature amplifiers are used with a typical bandwidth of 2.5 GHz in a single sideband. Additionally the chirped-pulse spectrometer contains a high power amplifier of 200 mW for the excitation of molecules. Room temperature spectra of methyl cyanide and comparison of key features, such as measurement time, sensitivity, limitations and commonalities are shown in respect to identification of complex molecules of astrophysical importance. In addition, future developments for both setups will be discussed.

  16. How Judgments Change Following Comparison of Current and Prior Information

    PubMed Central

    Albarracin, Dolores; Wallace, Harry M.; Hart, William; Brown, Rick D.

    2013-01-01

    Although much observed judgment change is superficial and occurs without considering prior information, other forms of change also occur. Comparison between prior and new information about an issue may trigger change by influencing either or both the perceived strength and direction of the new information. In four experiments, participants formed and reported initial judgments of a policy based on favorable written information about it. Later, these participants read a second passage containing strong favorable or unfavorable information on the policy. Compared to control conditions, subtle and direct prompts to compare the initial and new information led to more judgment change in the direction of a second passage perceived to be strong. Mediation analyses indicated that comparison yielded greater perceived strength of the second passage, which in turn correlated positively with judgment change. Moreover, self-reports of comparison mediated the judgment change resulting from comparison prompts. PMID:23599557

  17. APMP Scale Comparison with Three Radiation Thermometers and Six Fixed-Point Blackbodies

    NASA Astrophysics Data System (ADS)

    Yamada, Y.; Shimizu, Y.; Ishii, J.

    2015-08-01

    New Asia Pacific Metrology Programme (APMP) comparisons of radiation thermometry standards, APMP TS-11, and -12, have recently been initiated. These new APMP comparisons cover the temperature range from to . Three radiation thermometers with central wavelengths of 1.6 , 0.9 , and 0.65 are the transfer devices for the radiation thermometer scale comparison conducted in the so-called star configuration. In parallel, a compact fixed-point blackbody furnace that houses six types of fixed-point cells of In, Sn, Zn, Al, Ag, and Cu is circulated, again in a star-type comparison, to substantiate fixed-point calibration capabilities. Twelve APMP national metrology institutes are taking part in this endeavor, in which the National Metrology Institute of Japan acts as the pilot. In this article, the comparison scheme is described with emphasis on the features of the transfer devices, i.e., the radiation thermometers and the fixed-point blackbodies. Results of preliminary evaluations of the performance and characteristic of these instruments as well as the evaluation method of the comparison results are presented.

  18. Final report on bilateral supplementary comparison APMP.M.P-S5 in hydraulic gauge pressure from 1 MPa to 10 MPa

    NASA Astrophysics Data System (ADS)

    Yue, J.; Yang, Y.; Sabuga, W.

    2016-01-01

    This report summarizes the results of the Asia-Pacific Metrology Programme (APMP) supplementary comparison APMP.M.P-S5 for hydraulic gauge pressure in the range of 1 MPa to 10 MPa, which is a bilateral comparison carried out at the National Institute of Metrology, China (NIM) and the Physikalisch-Technische Bundesanstalt, Germany (PTB) during the period June 2014 to June 2015. NIM piloted the comparison and provided the transfer standard, which was a piston-cylinder assembly (PCA) of 1 cm2 nominal effective area built in a hydraulic pressure balance manufactured by Fluke Corporation. The laboratory standards of NIM and PTB are both hydraulic pressure balances equipped with PCAs, of which the nominal effective area is 1 cm2 for NIM and 5 cm2 for PTB. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards of NIM and PTB in the range of 1 MPa to 10 MPa are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. A simple and fast heuristic for protein structure comparison.

    PubMed

    Pelta, David A; González, Juan R; Moreno Vega, Marcos

    2008-03-25

    Protein structure comparison is a key problem in bioinformatics. There exist several methods for doing protein comparison, being the solution of the Maximum Contact Map Overlap problem (MAX-CMO) one of the alternatives available. Although this problem may be solved using exact algorithms, researchers require approximate algorithms that obtain good quality solutions using less computational resources than the formers. We propose a variable neighborhood search metaheuristic for solving MAX-CMO. We analyze this strategy in two aspects: 1) from an optimization point of view the strategy is tested on two different datasets, obtaining an error of 3.5%(over 2702 pairs) and 1.7% (over 161 pairs) with respect to optimal values; thus leading to high accurate solutions in a simpler and less expensive way than exact algorithms; 2) in terms of protein structure classification, we conduct experiments on three datasets and show that is feasible to detect structural similarities at SCOP's family and CATH's architecture levels using normalized overlap values. Some limitations and the role of normalization are outlined for doing classification at SCOP's fold level. We designed, implemented and tested.a new tool for solving MAX-CMO, based on a well-known metaheuristic technique. The good balance between solution's quality and computational effort makes it a valuable tool. Moreover, to the best of our knowledge, this is the first time the MAX-CMO measure is tested at SCOP's fold and CATH's architecture levels with encouraging results.

  20. Comparison of Fiber Optic Strain Demodulation Implementations

    NASA Technical Reports Server (NTRS)

    Quach, Cuong C.; Vazquez, Sixto L.

    2005-01-01

    NASA Langley Research Center is developing instrumentation based upon principles of Optical Frequency-Domain Reflectometry (OFDR) for the provision of large-scale, dense distribution of strain sensors using fiber optics embedded with Bragg gratings. Fiber Optic Bragg Grating technology enables the distribution of thousands of sensors immune to moisture and electromagnetic interference with negligible weight penalty. At Langley, this technology provides a key component for research and development relevant to comprehensive aerospace vehicle structural health monitoring. A prototype system is under development that includes hardware and software necessary for the acquisition of data from an optical network and conversion of the data into strain measurements. This report documents the steps taken to verify the software that implements the algorithm for calculating the fiber strain. Brief descriptions of the strain measurement system and the test article are given. The scope of this report is the verification of software implementations as compared to a reference model. The algorithm will be detailed along with comparison results.

  1. Force supplementary comparison at SIM (SIM.M.F-S5), compression testing machines calibration, up to 200 kN

    NASA Astrophysics Data System (ADS)

    Cárdenas Moctezuma, A.; Torres Guzmán, J. C.

    2016-01-01

    CENAM, through the Force and Pressure Division, organized a comparison on testing machines calibration, in compression mode. The participating laboratories were SIM National Institutes of Metrology from Colombia, Peru and Costa Rica, where CENAM, Mexico was the pilot and reference laboratory. The results obtained by the laboratories are presented in this paper as well as the analysis of compatibility. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. 7 CFR 28.179 - Methods of cotton classification and comparison.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...

  3. 7 CFR 28.179 - Methods of cotton classification and comparison.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...

  4. 7 CFR 28.179 - Methods of cotton classification and comparison.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...

  5. 7 CFR 28.179 - Methods of cotton classification and comparison.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...

  6. 7 CFR 28.179 - Methods of cotton classification and comparison.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...

  7. Comparisons of neutrino event generators from an oscillation-experiment perspective

    NASA Astrophysics Data System (ADS)

    Mayer, Nathan

    2015-05-01

    Monte Carlo generators are crucial to the analysis of high energy physics data, ideally giving a baseline comparison between the state-of-art theoretical models and experimental data. Presented here is a comparison between three of final state distributions from the GENIE, Neut, NUANCE, and NuWro neutrino Monte Carlo event generators. The final state distributions chosen for comparison are: the electromagnetic energy fraction in neutral current interactions, the energy of the leading π0 vs. the scattering angle for neutral current interactions, and the muon energy vs. scattering angle of νµ charged current interactions.

  8. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    DTIC Science & Technology

    2018-03-26

    HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...Report March 2016 – August 2017 Approved for public release; distribution is unlimited U.S. Army Natick Soldier Research ...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  9. Longitudinal Relationships among Internalization of the Media Ideal, Peer Social Comparison, and Body Dissatisfaction: Implications for the Tripartite Influence Model

    ERIC Educational Resources Information Center

    Rodgers, Rachel F.; McLean, Siân A.; Paxton, Susan J.

    2015-01-01

    Sociocultural theory of body dissatisfaction posits that internalization of the media ideal and appearance comparison are predictors of body dissatisfaction, a key risk factor for eating disorders. However, no data exist regarding the longitudinal relationships between these variables. The aim of this study was to explore longitudinal…

  10. Price comparisons on the internet based on computational intelligence.

    PubMed

    Kim, Jun Woo; Ha, Sung Ho

    2014-01-01

    Information-intensive Web services such as price comparison sites have recently been gaining popularity. However, most users including novice shoppers have difficulty in browsing such sites because of the massive amount of information gathered and the uncertainty surrounding Web environments. Even conventional price comparison sites face various problems, which suggests the necessity of a new approach to address these problems. Therefore, for this study, an intelligent product search system was developed that enables price comparisons for online shoppers in a more effective manner. In particular, the developed system adopts linguistic price ratings based on fuzzy logic to accommodate user-defined price ranges, and personalizes product recommendations based on linguistic product clusters, which help online shoppers find desired items in a convenient manner.

  11. Price Comparisons on the Internet Based on Computational Intelligence

    PubMed Central

    Kim, Jun Woo; Ha, Sung Ho

    2014-01-01

    Information-intensive Web services such as price comparison sites have recently been gaining popularity. However, most users including novice shoppers have difficulty in browsing such sites because of the massive amount of information gathered and the uncertainty surrounding Web environments. Even conventional price comparison sites face various problems, which suggests the necessity of a new approach to address these problems. Therefore, for this study, an intelligent product search system was developed that enables price comparisons for online shoppers in a more effective manner. In particular, the developed system adopts linguistic price ratings based on fuzzy logic to accommodate user-defined price ranges, and personalizes product recommendations based on linguistic product clusters, which help online shoppers find desired items in a convenient manner. PMID:25268901

  12. Methods to prefetch comparison images in image management and communication system

    NASA Astrophysics Data System (ADS)

    Levin, Kenneth; Fielding, Robert

    1990-08-01

    A high-level description of a system to pre-fetch comparison radiographs in an Image Management and Communication System (IMAC) is presented. This rule based system estimates the relevance of previous examinations for comparison to the current examination arid uses this determination to pre-fetch comparison studies. A machine learning module should allow the system to improve its skill in pre-fetching examinations for each individual radiologist. This system could be tailored to fit the desires of individual radiologists.

  13. The DoD C-17 Versus the Boeing 777. A Comparison of Acquisition and Development

    DTIC Science & Technology

    1999-10-01

    believed enough in what I was doing to encourage Mr. Condit to see me. Philip Condit, then President and now CEO of The Boeing Company , not only...maintain the superiority of the American military at less cost with more efficient methods. Therefore, whatever lessons we can learn from a comparison...opportuni- ties that enhance objectives. 1 One of the keys to successful management is in identifying and defining what to change: Every company has two

  14. Model Comparison of Bayesian Semiparametric and Parametric Structural Equation Models

    ERIC Educational Resources Information Center

    Song, Xin-Yuan; Xia, Ye-Mao; Pan, Jun-Hao; Lee, Sik-Yum

    2011-01-01

    Structural equation models have wide applications. One of the most important issues in analyzing structural equation models is model comparison. This article proposes a Bayesian model comparison statistic, namely the "L[subscript nu]"-measure for both semiparametric and parametric structural equation models. For illustration purposes, we consider…

  15. Drop size distribution comparisons between Parsivel and 2-D video disdrometers

    NASA Astrophysics Data System (ADS)

    Thurai, M.; Petersen, W. A.; Tokay, A.; Schultz, C.; Gatlin, P.

    2011-05-01

    Measurements from a 2-D video disdrometer (2DVD) have been used for drop size distribution (DSD) comparisons with co-located Parsivel measurements in Huntsville, Alabama. The comparisons were made in terms of the mass-weighted mean diameter, Dm, the standard deviation of the mass-spectrum, σm, and the rainfall rate, R, all based on 1-min DSD from the two instruments. Time series comparisons show close agreement in all three parameters for cases where R was less than 20 mm h-1. In four cases, discrepancies in all three parameters were seen for "heavy" events, with the Parsivel showing higher Dm, σm and R, when R reached high values (particularly above 30 mm h-1). Possible causes for the discrepancies include the presence of a small percentage of non-fully melted hydrometers, with higher than expected fall velocity and with very different axis ratios as compared with rain, indicating small hail or ice pellets or graupel. We also present here Parsivel-to-Parsivel comparisons as well as comparisons between two 2DVD instruments, namely a low-profile unit and the latest generation, "compact unit" which was installed at the same site in November 2009. The comparisons are included to assess the variability between the same types of instrument. Correlation coefficients and the fractional standard errors are compared.

  16. Selection of comparison crash types for quasi-induced exposure risk estimation.

    PubMed

    Keall, Michael; Newstead, Stuart

    2009-03-01

    The objective of this study was to find a comparison crash type that best represented exposure on the road and to identify situations where the induced exposure risk estimates were likely to be biased. Counts of crash involvements were compared with distance driven estimates derived from a register of licensed motor vehicles to identify the most appropriate comparison crash type for induced exposure estimation, which is the crash type whose counts are best correlated with vehicle distance driven. The best sets of comparison crashes for disaggregations by driver age and gender and vehicle type were found to be multi-vehicle crashes in which the vehicle was damaged in the rear or multi-vehicle crashes in which the driver was adjudged to be not at fault. Likely bias of induced exposure risk estimates was identified, even for these best sets of comparison crashes, according to vehicle size (with large vehicles underrepresented) and owner age and gender (with young owners and female owners overrepresented). This research identified some important features of crash occurrence useful for making choices of comparison crash types when controlling for exposure. None of the crash types considered as comparison crashes performed perfectly. Even the crash types that seemed to best reflect exposure on the road still appeared to over- or underestimate distance driven according to owner age group, gender, and vehicle size.

  17. An experimental manipulation of social comparison in social anxiety.

    PubMed

    Mitchell, Melissa A; Schmidt, Norman B

    2014-01-01

    Negative self-appraisal is thought to maintain social anxiety particularly when comparing oneself to others. Work on social comparison suggests that gender may moderate the effects of social comparison in social anxiety. Self-appraisals of the desirability of one's personality may be more important to women, whereas self-appraisal of signs of anxiety may be more important to men. Within each gender, those with high social anxiety are expected to report more negative self-appraisal when comparing themselves to someone else described as high achieving. This study is the first we are aware of that examined gender-based interactive effects after a social comparison manipulation. Participants read a bogus profile of a fellow student's adjustment to college. They were randomly assigned to read a profile suggesting that the fellow student was "high achieving" or more normative in his/her achievements. When comparing to a "high achieving" individual, men with high social anxiety reported the most negative self-appraisals of their signs of anxiety. In addition, greater social anxiety was associated with a poorer self-appraisal of personality only among men. The implications of the findings for conceptualizing the role of social comparison in social anxiety are discussed.

  18. Ground and Space Radar Volume Matching and Comparison Software

    NASA Technical Reports Server (NTRS)

    Morris, Kenneth; Schwaller, Mathew

    2010-01-01

    This software enables easy comparison of ground- and space-based radar observations. The software was initially designed to compare ground radar reflectivity from operational, ground based Sand C-band meteorological radars with comparable measurements from the Tropical Rainfall Measuring Mission (TRMM) satellite s Precipitation Radar (PR) instrument. The software is also applicable to other ground-based and space-based radars. The ground and space radar volume matching and comparison software was developed in response to requirements defined by the Ground Validation System (GVS) of Goddard s Global Precipitation Mission (GPM) project. This software innovation is specifically concerned with simplifying the comparison of ground- and spacebased radar measurements for the purpose of GPM algorithm and data product validation. This software is unique in that it provides an operational environment to routinely create comparison products, and uses a direct geometric approach to derive common volumes of space- and ground-based radar data. In this approach, spatially coincident volumes are defined by the intersection of individual space-based Precipitation Radar rays with the each of the conical elevation sweeps of the ground radar. Thus, the resampled volume elements of the space and ground radar reflectivity can be directly compared to one another.

  19. [Flicker comparison of optic disc photographs: sensitivity and specificity].

    PubMed

    Funk, Jens; Lagrèze, Wolf; Zeyen, Thierry

    2002-12-01

    Examination and documentation of the optic nerve head are essential in monitoring glaucoma patients. Even minor changes in optic nerve head morphology can be visualised using the so-called flicker test: Two optic nerve head photographs, taken at consecutive examinations, are superimposed by projection. When occluding the pictures in a rapid alternating fashion, changes in optic nerve head morphology appear as motion. In this study, we evaluated sensitivity and specificity of the flicker test. A set of 33 pairs of serial optic disc slides was used as gold standard. These 33 pairs had been classified earlier by 3 independent groups of experts. 23 had been classified as "no change over time", 10 had been classified as "change". All 33 pairs were now evaluated by flicker comparison in a masked fashion. Flicker comparison usually took 1 minute per pair of slides. Sensitivity was 90 %, specificity was 65 %. The sensitivity was reasonably high. The moderate specificity was due to some cases showing "change" with the flicker comparison which might have been overlooked by the expert groups. Flicker comparison is an easy, fast and reliable technique to evaluate pairs of consecutive optic disc photographs.

  20. Development of fraction comparison strategies: A latent transition analysis.

    PubMed

    Rinne, Luke F; Ye, Ai; Jordan, Nancy C

    2017-04-01

    The present study investigated the development of fraction comparison strategies through a longitudinal analysis of children's responses to a fraction comparison task in 4th through 6th grades (N = 394). Participants were asked to choose the larger value for 24 fraction pairs blocked by fraction type. Latent class analysis of performance over item blocks showed that most children initially exhibited a "whole number bias," indicating that larger numbers in numerators and denominators produce larger fraction values. However, some children instead chose fractions with smaller numerators and denominators, demonstrating a partial understanding that smaller numbers can yield larger fractions. Latent transition analysis showed that most children eventually adopted normative comparison strategies. Children who exhibited a partial understanding by choosing fractions with smaller numbers were more likely to adopt normative comparison strategies earlier than those with larger number biases. Controlling for general math achievement and other cognitive abilities, whole number line estimation accuracy predicted the probability of transitioning to normative comparison strategies. Exploratory factor analyses showed that over time, children appeared to increasingly represent fractions as discrete magnitudes when simpler strategies were unavailable. These results support the integrated theory of numerical development, which posits that an understanding of numbers as magnitudes unifies the process of learning whole numbers and fractions. The findings contrast with conceptual change theories, which propose that children must move from a view of numbers as counting units to a new view that accommodates fractions to overcome whole number bias. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  1. Finding a Comparison Group: Is Online Crowdsourcing a Viable Option?

    ERIC Educational Resources Information Center

    Azzam, Tarek; Jacobson, Miriam R.

    2013-01-01

    This article explores the viability of online crowdsourcing for creating matched-comparison groups. This exploratory study compares survey results from a randomized control group to survey results from a matched-comparison group created from Amazon.com's MTurk crowdsourcing service to determine their comparability. Study findings indicate…

  2. 29 CFR 570.103 - Comparison with wage and hour provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... REGULATIONS CHILD LABOR REGULATIONS, ORDERS AND STATEMENTS OF INTERPRETATION General Statements of Interpretation of the Child Labor Provisions of the Fair Labor Standards Act of 1938, as Amended General § 570.103 Comparison with wage and hour provisions. A comparison of the child labor provisions with the so...

  3. 29 CFR 570.103 - Comparison with wage and hour provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... REGULATIONS CHILD LABOR REGULATIONS, ORDERS AND STATEMENTS OF INTERPRETATION General Statements of Interpretation of the Child Labor Provisions of the Fair Labor Standards Act of 1938, as Amended General § 570.103 Comparison with wage and hour provisions. A comparison of the child labor provisions with the so...

  4. 29 CFR 570.103 - Comparison with wage and hour provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... REGULATIONS CHILD LABOR REGULATIONS, ORDERS AND STATEMENTS OF INTERPRETATION General Statements of Interpretation of the Child Labor Provisions of the Fair Labor Standards Act of 1938, as Amended General § 570.103 Comparison with wage and hour provisions. A comparison of the child labor provisions with the so...

  5. 29 CFR 570.103 - Comparison with wage and hour provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... REGULATIONS CHILD LABOR REGULATIONS, ORDERS AND STATEMENTS OF INTERPRETATION General Statements of Interpretation of the Child Labor Provisions of the Fair Labor Standards Act of 1938, as Amended General § 570.103 Comparison with wage and hour provisions. A comparison of the child labor provisions with the so...

  6. Brain mechanisms of social comparison and their influence on the reward system.

    PubMed

    Kedia, Gayannée; Mussweiler, Thomas; Linden, David E J

    2014-11-12

    Whenever we interact with others, we judge them and whenever we make such judgments, we compare them with ourselves, other people, or internalized standards. Countless social psychological experiments have shown that comparative thinking plays a ubiquitous role in person perception and social cognition as a whole. The topic of social comparison has recently aroused the interest of social neuroscientists, who have begun to investigate its neural underpinnings. The present article provides an overview of these neuroimaging and electrophysiological studies. We discuss recent findings on the consequences of social comparison on the brain processing of outcomes and highlight the role of the brain's reward system. Moreover, we analyze the relationship between the brain networks involved in social comparisons and those active during other forms of cognitive and perceptual comparison. Finally, we discuss potential future questions that research on the neural correlates of social comparison could address.

  7. Results of Second Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, I.; Grobner, J.; Wacker, S.

    The Absolute Cavity Pyrgeometer (ACP) and InfraRed Integrating Sphere radiometer (IRIS) are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are un-windowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The second outdoor comparison between the two designs was held from September 30 to October 11, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of the IRIS was within 1 W/m2 (3 IRISs: PMOD + Australia + Germany). From the first and second comparisons, a differencemore » of 4-6 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG). This presentation includes results from the first and second comparison in an effort to establish the world reference for pyrgeometer calibrations, a key deliverable for the World Meteorological Organization (WMO), and the DOE-ASR.« less

  8. DE/ISIS conjunction comparisons of high-latitude electron density features

    NASA Technical Reports Server (NTRS)

    Hoegy, Walter R.; Benson, Robert F.

    1988-01-01

    This paper presents a comparison between the ISIS-1 and -2 topside sounder measurements of electron number density, N(e), with the in situ ion and N(e) measurements by the Langmuir probe aboard the Dynamics Explorer 2 (DE 2) during four high-latitude ISIS/DE magnetic field-aligned conjunctions. The ISIS-derived N(e) values, even at the greatest distance from the sounder, were found to agree with the Langmuir probe measurements to within about 30 percent over a density range of more than two decades on three of the four comparisons; the fourth comparison which included data with strong N(e) irregularities, showed a difference of 60 percent.

  9. A comparison of hypersonic vehicle flight and prediction results

    NASA Technical Reports Server (NTRS)

    Iliff, Kenneth W.; Shafer, Mary F.

    1995-01-01

    Aerodynamic and aerothermodynamic comparisons between flight and ground test for four hypersonic vehicles are discussed. The four vehicles are the X-15, the Reentry F, the Sandia Energetic Reentry Vehicle Experiment (SWERVE), and the Space Shuttle. The comparisons are taken from papers published by researchers active in the various programs. Aerodynamic comparisons include reaction control jet interaction on the Space Shuttle. Various forms of heating including catalytic, boundary layer, shock interaction and interference, and vortex impingement are compared. Predictions were significantly exceeded for the heating caused by vortex impingement (on the Space Shuttle OMS pods) and for heating caused by shock interaction and interference on the X-15 and the Space Shuttle. Predictions of boundary-layer state were in error on the X-15, the SWERVE, and the Space Shuttle vehicles.

  10. A Toolbox for Teaching Price Comparison to Students with Disabilities

    ERIC Educational Resources Information Center

    Weng, Pei-Lin; Bouck, Emily C.

    2017-01-01

    Price comparison is a functional mathematics skill involving purchasing, use of money, and budgeting, with the goal of selecting the best deal based on a person's financial resources (Browder, Spooner, & Trela, 2011). The operational definition of "price comparison" is to compare the magnitudes of the price numbers and then select…

  11. Group Comparisons of Mathematics Performance from a Cognitive Diagnostic Perspective

    ERIC Educational Resources Information Center

    Chen, Yi-Hsin; Ferron, John M.; Thompson, Marilyn S.; Gorin, Joanna S.; Tatsuoka, Kikumi K.

    2010-01-01

    Traditional comparisons of test score means identify group differences in broad academic areas, but fail to provide substantive description of how the groups differ on the specific cognitive attributes required for success in the academic area. The rule space method (RSM) allows for group comparisons at the cognitive attribute level, which…

  12. Stable isotopic comparison between loggerhead sea turtle tissues.

    PubMed

    Vander Zanden, Hannah B; Tucker, Anton D; Bolten, Alan B; Reich, Kimberly J; Bjorndal, Karen A

    2014-10-15

    Stable isotope analysis has been used extensively to provide ecological information about diet and foraging location of many species. The difference in isotopic composition between animal tissue and its diet, or the diet-tissue discrimination factor, varies with tissue type. Therefore, direct comparisons between isotopic values of tissues are inaccurate without an appropriate conversion factor. We focus on the loggerhead sea turtle (Caretta caretta), for which a variety of tissues have been used to examine diet, habitat use, and migratory origin through stable isotope analysis. We calculated tissue-to-tissue conversions between two commonly sampled tissues. Epidermis and scute (the keratin covering on the carapace) were sampled from 33 adult loggerheads nesting at two beaches in Florida (Casey Key and Canaveral National Seashore). Carbon and nitrogen stable isotope ratios were measured in the epidermis and the youngest portion of the scute tissue, which reflect the isotopic composition of the diet and habitat over similar time periods of the order of several months. Significant linear relationships were observed between the δ(13)C and δ(15)N values of these two tissues, indicating they can be converted reliably. Whereas both epidermis and scute samples are commonly sampled from nesting sea turtles to study trophic ecology and habitat use, the data from these studies have not been comparable without reliable tissue-to-tissue conversions. The equations provided here allow isotopic datasets using the two tissues to be combined in previously published and subsequent studies of sea turtle foraging ecology and migratory movement. In addition, we recommend that future isotopic comparisons between tissues of any organism utilize linear regressions to calculate tissue-to-tissue conversions. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Data-Model Comparison of Pliocene Sea Surface Temperature

    NASA Astrophysics Data System (ADS)

    Dowsett, H. J.; Foley, K.; Robinson, M. M.; Bloemers, J. T.

    2013-12-01

    The mid-Piacenzian (late Pliocene) climate represents the most geologically recent interval of long-term average warmth and shares similarities with the climate projected for the end of the 21st century. As such, its fossil and sedimentary record represents a natural experiment from which we can gain insight into potential climate change impacts, enabling more informed policy decisions for mitigation and adaptation. We present the first systematic comparison of Pliocene sea surface temperatures (SST) between an ensemble of eight climate model simulations produced as part of PlioMIP (Pliocene Model Intercomparison Project) and the PRISM (Pliocene Research, Interpretation and Synoptic Mapping) Project mean annual SST field. Our results highlight key regional (mid- to high latitude North Atlantic and tropics) and dynamic (upwelling) situations where there is discord between reconstructed SST and the PlioMIP simulations. These differences can lead to improved strategies for both experimental design and temporal refinement of the palaeoenvironmental reconstruction. Scatter plot of multi-model-mean anomalies (squares) and PRISM3 data anomalies (large blue circles) by latitude. Vertical bars on data anomalies represent the variability of warm climate phase within the time-slab at each locality. Small colored circles represent individual model anomalies and show the spread of model estimates about the multi-model-mean. While not directly comparable in terms of the development of the means nor the meaning of variability, this plot provides a first order comparison of the anomalies. Encircled areas are a, PRISM low latitude sites outside of upwelling areas; b, North Atlantic coastal sequences and Mediterranean sites; c, large anomaly PRISM sites from the northern hemisphere. Numbers identify Ocean Drilling Program sites.

  14. A Robust and Efficient Quantum Private Comparison of Equality Based on the Entangled Swapping of GHZ-like State and χ + State

    NASA Astrophysics Data System (ADS)

    Xu, Ling; Zhao, Zhiwen

    2017-08-01

    A new quantum protocol with the assistance of a semi-honest third party (TP) is proposed, which allows the participants comparing the equality of their private information without disclosing them. Different from previous protocols, this protocol utilizes quantum key distribution against the collective-dephasing noise and the collective-rotation noise, which is more robust and abandons few samples, to transmit the classical information. In addition, this protocol utilizes the GHZ-like state and the χ + state to produce the entanglement swapping. And the Bell basis and the dual basis are used to measure the particle pair so that 3 bits of each participant's private information can be compared in each comparison time, which is more efficient and consumes fewer comparison times. Meanwhile, there is no need of unitary operation and hash function in this protocol. At the end, various kinds of outside attack and participant attack are discussed and analyzed to be invalid, so it can complete the comparison in security.

  15. Gender Differences in Comparisons and Entitlement: Implications for Comparable Worth.

    ERIC Educational Resources Information Center

    Major, Brenda

    1989-01-01

    Addresses the role of comparison processes in the persistence of the gender wage gap, its toleration by those disadvantaged by it, and resistance to comparable worth as a corrective strategy. Argues that gender segregation and undercompensation for women's jobs leads women to use different comparison standards when evaluating what they deserve.…

  16. The Influence of Counterfactual Comparison on Fairness in Gain-Loss Contexts.

    PubMed

    Li, Qi; Wang, Chunsheng; Taxer, Jamie; Yang, Zhong; Zheng, Ya; Liu, Xun

    2017-01-01

    Fairness perceptions may be affected by counterfactual comparisons. Although certain studies using a two-player ultimatum game (UG) have shown that comparison with the proposers influences the responders' fairness perceptions in a gain context, the effect of counterfactual comparison in a UG with multiple responders or proposers remains unclear, especially in a loss context. To resolve these issues, this study used a modified three-player UG with multiple responders in Experiment 1 and multiple proposers in Experiment 2 to examine the influence of counterfactual comparison on fairness-related decision-making in gain and loss contexts. The two experiments consistently showed that regardless of the gain or loss context, the level of inequality of the offer and counterfactual comparison influenced acceptance rates (ARs), response times (RTs), and fairness ratings (FRs). If the offers that were received were better than the counterfactual offers, unequal offers were more likely to be accepted than equal offers, and participants were more likely to report higher FRs and to make decisions more quickly. In contrast, when the offers they received were worse than the counterfactual offers, participants were more likely to reject unequal offers than equal offers, reported lower FRs, and made decisions more slowly. These results demonstrate that responders' fairness perceptions are influenced by not only comparisons of the absolute amount of money that they would receive but also specific counterfactuals from other proposers or responders. These findings improve our understanding of fairness perceptions.

  17. The Influence of Counterfactual Comparison on Fairness in Gain-Loss Contexts

    PubMed Central

    Li, Qi; Wang, Chunsheng; Taxer, Jamie; Yang, Zhong; Zheng, Ya; Liu, Xun

    2017-01-01

    Fairness perceptions may be affected by counterfactual comparisons. Although certain studies using a two-player ultimatum game (UG) have shown that comparison with the proposers influences the responders' fairness perceptions in a gain context, the effect of counterfactual comparison in a UG with multiple responders or proposers remains unclear, especially in a loss context. To resolve these issues, this study used a modified three-player UG with multiple responders in Experiment 1 and multiple proposers in Experiment 2 to examine the influence of counterfactual comparison on fairness-related decision-making in gain and loss contexts. The two experiments consistently showed that regardless of the gain or loss context, the level of inequality of the offer and counterfactual comparison influenced acceptance rates (ARs), response times (RTs), and fairness ratings (FRs). If the offers that were received were better than the counterfactual offers, unequal offers were more likely to be accepted than equal offers, and participants were more likely to report higher FRs and to make decisions more quickly. In contrast, when the offers they received were worse than the counterfactual offers, participants were more likely to reject unequal offers than equal offers, reported lower FRs, and made decisions more slowly. These results demonstrate that responders' fairness perceptions are influenced by not only comparisons of the absolute amount of money that they would receive but also specific counterfactuals from other proposers or responders. These findings improve our understanding of fairness perceptions. PMID:28536542

  18. Railroad safety : U.S.-Canadian comparison

    DOT National Transportation Integrated Search

    1979-08-01

    In June 1978, Congress requested the Office of Technology Assessment (OTA) to : conduct "a detailed comparison between conditions prevailing in railway safety : in the United States and a review of safety operations in Canada. " Responding : to this ...

  19. The road not taken: social vs. private comparisons in Asperger׳s syndrome and high functioning autism.

    PubMed

    Dvash, Jonathan; Ben-Zèev, Aaron; Noga, Adler; Shamay-Tsoory, Simone

    2014-05-30

    Evaluation of the outcomes of our decisions may instigate comparisons of our actual outcome with those of others (social comparisons) or comparisons with alternative outcomes of choices not made (private comparisons). Previous research has suggested a deficit in attention to social information among individuals with autism spectrum disorders. As social comparison involves the processing of social information, here we investigated the orientation towards and sensitivity to social vs. private comparisons in individuals with autism spectrum disorders. We compared the sensitivity to social vs. private comparisons among individuals diagnosed with Asperger's Syndrome (AS) or High Functioning Autism, using a task that entailed monetary rewards. Results showed that while individuals with AS generally demonstrate comparable sensitivity to absolute and relative rewards, they show less sensitivity to social comparison as compared to controls. Furthermore, they are characterized by a higher sensitivity to private rather than social comparison. These results suggest that low sensitivity to social comparisons is an important factor to consider in autism spectrum disorders. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Inhibition in Dot Comparison Tasks

    ERIC Educational Resources Information Center

    Clayton, Sarah; Gilmore, Camilla

    2015-01-01

    Dot comparison tasks are commonly used to index an individual's Approximate Number System (ANS) acuity, but the cognitive processes involved in completing these tasks are poorly understood. Here, we investigated how factors including numerosity ratio, set size and visual cues influence task performance. Forty-four children aged 7-9 years completed…

  1. International Comparisons and Educational Reform.

    ERIC Educational Resources Information Center

    Purves, Alan C., Ed.

    Increasingly over the past decade there have appeared in the press bar graphs comparing the performance of U.S. students with their counterparts in other countries. Usually these graphs have been accompanied by dire warnings and pointing fingers. The main source of the data on international comparisons has been the International Association for…

  2. Shifting social identities as a strategy for deflecting threatening social comparisons.

    PubMed

    Mussweiler, T; Gabriel, S; Bodenhausen, G V

    2000-09-01

    Results of three studies suggest that the multifaceted nature of identity provides a strategic basis for reducing the threat involved in upward social comparisons. After performing worse than a comparison standard, people may strategically emphasize aspects of their identity that differentiate them from the standard, thereby making the standard less relevant for self-evaluation. On the basis of previous research showing that persons low in self-esteem are less likely to make effective use of self-protection strategies, we hypothesized that this strategy of deflecting the threat involved in upward comparison (i.e., decreasing perceived comparability by emphasizing an unshared social identity) would be used primarily by persons who are characteristically high in self-esteem. This pattern was confirmed in three studies. Moreover, use of the strategy was associated with relatively more positive affect following threatening upward comparisons.

  3. Bilateral comparison on the calibration of a set of F1 mass standards between IBMETRO (Bolivia) and INTI (Argentina)

    NASA Astrophysics Data System (ADS)

    Quille, Ruben; Sanchez, Jorge; Escalante, Boris

    2017-01-01

    Mass calibration is an important activity for National Metrology Institutes (NMIs), due to the amount of measurements on scientific, industrial and legal activities that have traceability to the national mass standards of each country. In order to evaluate the stated uncertainty and degree of equivalence between INTI-Argentina and IBMETRO-Bolivia on mass calibration a bilateral comparison was agreed between both laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Dose finding with the sequential parallel comparison design.

    PubMed

    Wang, Jessie J; Ivanova, Anastasia

    2014-01-01

    The sequential parallel comparison design (SPCD) is a two-stage design recommended for trials with possibly high placebo response. A drug-placebo comparison in the first stage is followed in the second stage by placebo nonresponders being re-randomized between drug and placebo. We describe how SPCD can be used in trials where multiple doses of a drug or multiple treatments are compared with placebo and present two adaptive approaches. We detail how to analyze data in such trials and give recommendations about the allocation proportion to placebo in the two stages of SPCD.

  5. Inter-comparison of three-dimensional models of volcanic plumes

    USGS Publications Warehouse

    Suzuki, Yujiro; Costa, Antonio; Cerminara, Matteo; Esposti Ongaro, Tomaso; Herzog, Michael; Van Eaton, Alexa; Denby, Leif

    2016-01-01

    %. This inter-comparison study has highlighted the different capabilities of 3D volcanic plume models, and identified key features of weak and strong plumes, including the roles of jet stability, entrainment efficiency, and particle non-equilibrium, which deserve future investigation in field, laboratory, and numerical studies.

  6. A trans-cultural comparison of the organisation of care at headache centres world-wide.

    PubMed

    Bhola, Ria; Goadsby, Peter J

    2011-02-01

    The need to provide better outcomes for patients with headache, and to minimise the costs involved in doing so, has prompted the search for new modes of service delivery by exploring the service organisation and nursing role from various cultural, economic and global perspectives. This study was based on comparisons with the UK headache service up to 2007, the point at which this study was set up. This UK service was based at the National Hospital for Neurology and Neurosurgery (NHNN, UCLH Trust). Data were obtained from US headache centres in 2008 and from centres in Copenhagen, Bangkok, Sydney and Porto Alegre in 2009. A comparison shows the key components of services at all centres showing the team structure and size of service. Prominent features at the centres included: team-working, regular meetings, educational input, good access and communication among team members, headache-trained neurologists, specialist nursing at most centres, and the input of psychological and physical therapists at some centres. The problems of tertiary headache care are very similar throughout the world and seem to transcend ethnic, cultural and economic considerations.

  7. The Effectiveness of Guided Inquiry Learning for Comparison Topics

    NASA Astrophysics Data System (ADS)

    Asnidar; Khabibah, S.; Sulaiman, R.

    2018-01-01

    This research aims at producing a good quality learning device using guided inquiry for comparison topics and describing the effectiveness of guided inquiry learning for comparison topics. This research is a developmental research using 4-D model. The result is learning device consisting of lesson plan, student’s worksheet, and achievement test. The subjects of the study were class VII students, each of which has 46 students. Based on the result in the experimental class, the learning device using guided inquiry for comparison topics has good quality. The learning device has met the valid, practical, and effective aspects. The result, especially in the implementation class, showed that the learning process with guided inquiry has fulfilled the effectiveness indicators. The ability of the teacher to manage the learning process has fulfilled the criteria good. In addition, the students’ activity has fulfilled the criteria of, at least, good. Moreover, the students’ responses to the learning device and the learning activities were positive, and the students were able to complete the classical learning. Based on the result of this research, it is expected that the learning device resulted can be used as an alternative learning device for teachers in implementing mathematic learning for comparison topics.

  8. Eye movements reflect and shape strategies in fraction comparison

    PubMed Central

    Ischebeck, Anja; Weilharter, Marina; Körner, Christof

    2016-01-01

    The comparison of fractions is a difficult task that can often be facilitated by separately comparing components (numerators and denominators) of the fractions—that is, by applying so-called component-based strategies. The usefulness of such strategies depends on the type of fraction pair to be compared. We investigated the temporal organization and the flexibility of strategy deployment in fraction comparison by evaluating sequences of eye movements in 20 young adults. We found that component-based strategies could account for the response times and the overall number of fixations observed for the different fraction pairs. The analysis of eye movement sequences showed that the initial eye movements in a trial were characterized by stereotypical scanning patterns indicative of an exploratory phase that served to establish the kind of fraction pair presented. Eye movements that followed this phase adapted to the particular type of fraction pair and indicated the deployment of specific comparison strategies. These results demonstrate that participants employ eye movements systematically to support strategy use in fraction comparison. Participants showed a remarkable flexibility to adapt to the most efficient strategy on a trial-by-trial basis. Our results confirm the value of eye movement measurements in the exploration of strategic adaptation in complex tasks. PMID:26039819

  9. Eye movements reflect and shape strategies in fraction comparison.

    PubMed

    Ischebeck, Anja; Weilharter, Marina; Körner, Christof

    2016-01-01

    The comparison of fractions is a difficult task that can often be facilitated by separately comparing components (numerators and denominators) of the fractions--that is, by applying so-called component-based strategies. The usefulness of such strategies depends on the type of fraction pair to be compared. We investigated the temporal organization and the flexibility of strategy deployment in fraction comparison by evaluating sequences of eye movements in 20 young adults. We found that component-based strategies could account for the response times and the overall number of fixations observed for the different fraction pairs. The analysis of eye movement sequences showed that the initial eye movements in a trial were characterized by stereotypical scanning patterns indicative of an exploratory phase that served to establish the kind of fraction pair presented. Eye movements that followed this phase adapted to the particular type of fraction pair and indicated the deployment of specific comparison strategies. These results demonstrate that participants employ eye movements systematically to support strategy use in fraction comparison. Participants showed a remarkable flexibility to adapt to the most efficient strategy on a trial-by-trial basis. Our results confirm the value of eye movement measurements in the exploration of strategic adaptation in complex tasks.

  10. Final report on APMP.M.M.K4.1—bilateral comparison of 1 kg stainless steel mass standards between KRISS and A*STAR

    NASA Astrophysics Data System (ADS)

    Chung, J. W.; Lee, S. M.; Lee, S. J.

    2017-01-01

    This report describes a bilateral comparison of 1 kg stainless steel mass standard between the Korea Research Institute of Standards and Science (KRISS), and the National Measurement Centre, Agency for Science, Technology and Research (A*STAR), Singapore, which is registered in the BIPM KCDB as APMP.M.M-K4.1. This nominal value was chosen as it followed the nominal value of CCM.M-K4. This bilateral comparison was piloted by KRISS. The transfer weight was delivered to A*STAR from KRISS in April 2015 and received back from A*STAR in October 2015. A*STAR are aiming to improve their calibration measurement capability (CMC) for mass of 1 kg. KRISS participated in both this comparison and CCM.M-K4, providing a link between the A*STAR result and the KCRV of CCM.M-K4. The final report of this comparison is given in this document. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Robot Trajectories Comparison: A Statistical Approach

    PubMed Central

    Ansuategui, A.; Arruti, A.; Susperregi, L.; Yurramendi, Y.; Jauregi, E.; Lazkano, E.; Sierra, B.

    2014-01-01

    The task of planning a collision-free trajectory from a start to a goal position is fundamental for an autonomous mobile robot. Although path planning has been extensively investigated since the beginning of robotics, there is no agreement on how to measure the performance of a motion algorithm. This paper presents a new approach to perform robot trajectories comparison that could be applied to any kind of trajectories and in both simulated and real environments. Given an initial set of features, it automatically selects the most significant ones and performs a statistical comparison using them. Additionally, a graphical data visualization named polygraph which helps to better understand the obtained results is provided. The proposed method has been applied, as an example, to compare two different motion planners, FM2 and WaveFront, using different environments, robots, and local planners. PMID:25525618

  12. Comparison Groups in Yoga Research: A Systematic Review and Critical Evaluation of the Literature

    PubMed Central

    Groessl, Erik; Maiya, Meghan; Sarkin, Andrew; Eisen, Susan V.; Riley, Kristen; Elwy, A. Rani

    2014-01-01

    Objectives Comparison groups are essential for accurate testing and interpretation of yoga intervention trials. However, selecting proper comparison groups is difficult because yoga comprises a very heterogeneous set of practices and its mechanisms of effect have not been conclusively established. Methods We conducted a systematic review of the control and comparison groups used in published randomized controlled trials (RCTs) of yoga. Results We located 128 RCTs that met our inclusion criteria; of these, 65 included only a passive control and 63 included at least one active comparison group. Primary comparison groups were physical exercise (43%), relaxation/meditation (20%), and education (16%). Studies rarely provided a strong rationale for choice of comparison. Considering year of publication, the use of active controls in yoga research appears to be slowly increasing over time. Conclusions Given that yoga has been established as a potentially powerful intervention, future research should use active control groups. Further, care is needed to select comparison conditions that help to isolate the specific mechanisms of yoga’s effects. PMID:25440384

  13. Comparison of the NIST and ENEA Air Kerma Standards

    PubMed Central

    Laitano, R. F.; Lamperti, P. J.; Toni, M. P.

    1998-01-01

    A comparison was made between the National Institute of Standards and Technology (NIST) and Ente per le Nuove Tecnologie l’Energia e l’Ambiente (ENEA) air kerma standards for medium energy x rays and 60Co gamma rays. The comparison took place at ENEA in June 1994. Two different transfer chambers from NIST were used for the comparison. The measurements were made at radiation qualities similar to those used at the Bureau International des Poids et Mesures (BIPM) (generating voltages of 100 kV, 135 kV, 180 kV and 250 kV, respectively) and with 60Co gamma radiation. The transfer chamber calibration factors obtained at the NIST and at the ENEA agreed with one another to 0.03 % for 60Co gamma radiation and between 0.1 % to 0.8 % for the medium energy x-ray beam codes. PMID:28009356

  14. Effects of Comparison Question Type and Between Test Stimulation on the Validity of Comparison Question Test

    DTIC Science & Technology

    2009-09-08

    C. J., & Iacono, W. G. (1989). Psychopathy , threat, and polygraph test accuracy. Journal of Applied Psychology, 74, 347-355. Patrick, C. J... Psychopathy and detection of deception in a prison population. Psychophysiology, 15,121-136. Raskin, D. C, & Honts, C. R. (2002). The comparison question

  15. A simple and fast heuristic for protein structure comparison

    PubMed Central

    Pelta, David A; González, Juan R; Moreno Vega, Marcos

    2008-01-01

    Background Protein structure comparison is a key problem in bioinformatics. There exist several methods for doing protein comparison, being the solution of the Maximum Contact Map Overlap problem (MAX-CMO) one of the alternatives available. Although this problem may be solved using exact algorithms, researchers require approximate algorithms that obtain good quality solutions using less computational resources than the formers. Results We propose a variable neighborhood search metaheuristic for solving MAX-CMO. We analyze this strategy in two aspects: 1) from an optimization point of view the strategy is tested on two different datasets, obtaining an error of 3.5%(over 2702 pairs) and 1.7% (over 161 pairs) with respect to optimal values; thus leading to high accurate solutions in a simpler and less expensive way than exact algorithms; 2) in terms of protein structure classification, we conduct experiments on three datasets and show that is feasible to detect structural similarities at SCOP's family and CATH's architecture levels using normalized overlap values. Some limitations and the role of normalization are outlined for doing classification at SCOP's fold level. Conclusion We designed, implemented and tested.a new tool for solving MAX-CMO, based on a well-known metaheuristic technique. The good balance between solution's quality and computational effort makes it a valuable tool. Moreover, to the best of our knowledge, this is the first time the MAX-CMO measure is tested at SCOP's fold and CATH's architecture levels with encouraging results. Software is available for download at . PMID:18366735

  16. 6. September 1971 DETAIL VIEW OF CHAIN PADLOCK AND KEY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. September 1971 DETAIL VIEW OF CHAIN PADLOCK AND KEY TO SECURE DOOR TO MAIN CELL BLOCK, NOTE STANDARD MODERN PADLOCK FOR SIZE COMPARISON - Jefferson County Jail & Sheriff's Office, Courthouse Square, Madison, Jefferson County, IN

  17. Sample sizes and model comparison metrics for species distribution models

    Treesearch

    B.B. Hanberry; H.S. He; D.C. Dey

    2012-01-01

    Species distribution models use small samples to produce continuous distribution maps. The question of how small a sample can be to produce an accurate model generally has been answered based on comparisons to maximum sample sizes of 200 observations or fewer. In addition, model comparisons often are made with the kappa statistic, which has become controversial....

  18. Comparison of Aerosol Optical Depth from Four Solar Radiometers During the Fall 1997 ARM Intensive Observation Period

    NASA Technical Reports Server (NTRS)

    Schmid, B.; Michalsky, J.; Halthore, R.; Beauharnois, M.; Harrison, L.; Livingston, J.; Russell, P.; Holben, B.; Eck, T.; Smirnov, A.

    2000-01-01

    In the Fall of 1997 the Atmospheric Radiation Measurement (ARM) program conducted an Intensive Observation Period (IOP) to study aerosols. Five sun-tracking radiometers were present to measure the total column aerosol optical depth. This comparison performed on the Southern Great Plains (SGP) demonstrates the capabilities and limitations of modern tracking sunphotometers at a location typical of where aerosol measurements are required. The key result was agreement in aerosol optical depth measured by 4 of the 5 instruments within 0.015 (rms). The key to this level of agreement was meticulous care in the calibrations of the instruments.

  19. The Flight from Physics Education: Searching for Reasons by Comparisons across the Curriculum

    ERIC Educational Resources Information Center

    Monk, Martin

    2008-01-01

    Cross-curriculum comparisons help open up new perspectives on old issues. The flight from physics by students is one such issue. Here a comparison is made with music education and language education. Where these comparisons provide useful insights they can also warn against knee-jerk panaceas. It is suggested we need to understand how and why…

  20. EURAMET.M.P-S9 / EURAMET 1170, LOOP2. Comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Otal, P.; Boineau, F.; Medina, N.; Pražák, D.; Wüthrich, C.; Saxholm, S.; Sabuga, W.; Kocas, I.; Durgut, Y.

    2017-01-01

    This report gives the results of a comparison of pressure standards of seven European National Metrology institutes in the range of negative gauge pressure from -950 hPa to 0 hPa. This comparison was piloted by LNE and was carried out from January 2011 to March 2012. This work is a part of the EURAMET project 1170 and is registered as a supplementary comparison EURAMET.M.P-S9. The transfer standard used was a pressure monitor RPM4 A160Ks manufactured by DH Instruments Inc., with a resolution of 0.1 Pa. The reference values have been determined from the weighted mean of the deviations reported by the participants for each specified pressure. Seventy-three of the seventy-seven values (96%) reported by the laboratories agree with the reference values within the expanded uncertainties with a coverage factor k = 2. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).