Sample records for key comparison final

  1. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. KEY COMPARISON: Final report, on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII, 2007

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez Blaya, Carmen

    2009-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone mole fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. KEY COMPARISON: Final report on international key comparison CCQM-K53: Oxygen in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Bok Lee, Jin; Moon, Dong Min; Seog Kim, Jin; van der Veen, Adriaan M. H.; Besley, Laurie; Heine, Hans-Joachim; Martin, Belén; Konopelko, L. A.; Kato, Kenji; Shimosaka, Takuya; Perez Castorena, Alejandro; Macé, Tatiana; Milton, Martin J. T.; Kelley, Mike; Guenther, Franklin; Botha, Angelique

    2010-01-01

    Gravimetry is used as the primary method for the preparation of primary standard gas mixtures in most national metrology institutes, and it requires the combined abilities of purity assessment, weighing technique and analytical skills. At the CCQM GAWG meeting in October 2005, it was agreed that KRISS should coordinate a key comparison, CCQM-K53, on the gravimetric preparation of gas, at a level of 100 µmol/mol of oxygen in nitrogen. KRISS compared the gravimetric value of each cylinder with an analytical instrument. A preparation for oxygen gas standard mixture requires particular care to be accurate, because oxygen is a major component of the atmosphere. Key issues for this comparison are related to (1) the gravimetric technique which needs at least two steps for dilution, (2) oxygen impurity in nitrogen, and (3) argon impurity in nitrogen. The key comparison reference value is obtained from the linear regression line (with origin) of a selected set of participants. The KCRV subset, except one, agree with each other. The standard deviation of the x-residuals of this group (which consists of NMIJ, VSL, NIST, NPL, BAM, KRISS and CENAM) is 0.056 µmol/mol and consistent with the uncertainties given to their standard mixtures. The standard deviation of the residuals of all participating laboratory is 0.182 µmol/mol. With respect to impurity analysis, overall argon amounts of the cylinders are in the region of about 3 µmol/mol however; four cylinders showed an argon amount fraction over 10 µmol/mol. Two of these are inconsistent with the KCRV subset. The explicit separation between two peaks of oxygen and argon in the GC chromatogram is essential to maintain analytical capability. Additionally oxygen impurity analysis in nitrogen is indispensable to ensure the preparative capability. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The

  4. KEY COMPARISON: Final report of International Comparison EUROMET.QM-K1c: Comparison of measurements of nitrogen monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, A. M. H.; Nieuwenkamp, G.; Oudwater, R.; Wessel, R. M.; Novak, J.; Perrochet, J.-F.; Ackermann, A.; Rakowska, A.; Cortez, L.; Dias, F.; Konopelko, L.; Kustikov, Y.; Sutour, C.; Masé, T.; Milton, M. J. T.; Uprichard, I. J.; Woods, P. T.; Walden, J.; Lopez Esteban, M. T.

    2005-01-01

    Following-up the key comparison CCQM-K1c, EUROMET organized a regional key comparison involving ten laboratories. The objectives of this EUROMET key comparison were essentially the same as for the CCQM-K1c comparison: to compare the measurement capabilities of national metrological institutes (NMIs) in measuring amount of substance fractions of nitrogen monoxide in nitrogen. The nominal amount of substance fraction of the standards used for the comparison was 100 µmol/mol. The pilot laboratory in this key comparison also piloted the CCQM key comparison and has long-term experience in the behaviour of these mixtures and the technical challenges in preparing batches of very similar mixtures. Most participants used chemiluminescence as the measurement method; two participants used UV techniques and one ND-IR. The degrees of equivalence between this comparison and CCQM-K1c were calculated; four laboratories participated in both key comparisons, thus providing sufficient data for demonstrating the comparability. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  5. KEY COMPARISON Final report on international comparison CCQM-K71: Measurement of stack gas

    NASA Astrophysics Data System (ADS)

    Nieuwenkamp, G.; van der Veen, A. M. H.; Wessel, R. M.; Qiao, Han; Oh, Sang-Hyub; Kim, Byung-Moon; Kim, Kwang-Sub; Pérez Castorena, Alejandro; Ramírez Nambo, Carlos; Koelliker Delgado, Jorge; Serrano Caballero, Victor M.; Rangel Murillo, Francisco; Avila Salas, Manuel de Jesus; Dias, Florbela; Baptista, Gonçalo; Konopelko, L. A.; Kustikov, Y. A.; Pankratov, V. V.; Selyukov, D. N.; Balandovich, V. S.; Vishnyakov, I. M.; Pavlov, M. V.; Maltsev, M. A.; Botha, Angelique; Valkova, Miroslava; Stovcik, Viliam; Musil, Stanislav; Milton, M. J. T.; Uprichard, I. J.; Vargha, G. M.; Guenther, F.; Gameson, L.; da Cunha, V.

    2010-01-01

    Industrial stack gas emission measurements are important for process control, control of air pollution, and for implementing legislation regarding carbon dioxide emission rights. Measurements are typically performed using a range of process analysers for carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOx), sulphur dioxide (SO2) and miscellaneous hydrocarbons. The calibration of these analysers is often performed using a series of binary mixtures of each component in nitrogen. For reasons of efficiency as well as a better match with true stack gas, the use of multi-component mixtures for this purpose would be preferred. The aim of this key comparison is to evaluate the measurement capabilities of national metrology institutes for carbon monoxide, carbon dioxide, nitrogen monoxide, sulphur dioxide and propane in nitrogen. Ten laboratories participated in the key comparison and one in the associated study. The key comparison reference value is based on the gravimetric preparation data. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Final report on RMO Vickers key comparison COOMET M.H-K1

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Menelao, F.; Herrmann, K.; Aslanyan, A.; Pivovarov, V.; Galat, E.; Dovzhenko, Y.; Zhamanbalin, M.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales involving five National Metrology Institutes: PTB (Germany), BelGIM (Belarus), NSC IM (Ukraine), KazInMetr (Kazakhstan) and VNIIFTRI (Russia). The pilot laboratory was VNIIFTRI, and PTB acted as the linking institute to key comparisons CCM.H-K1.b and CCM.H-K1.c conducted for the Vickers hardness scales HV1 and HV30, respectively. The comparison was also conducted for the HV5 Vickers hardness scale, since this scale is most frequently used in practice in Russia and CIS countries that work according to GOST standards. In the key comparison, two sets of hardness reference blocks for the Vickers hardness scales HV1, HV5 and HV30 consisting each of three hardness reference blocks with hardness levels of 450 HV and 750 HV were used. The measurement results and uncertainty assessments for HV1 and HV30 hardness scales, as announced by BelGIM, NSC IM, KazInMetr and VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1.b and CCM.H-K1.c. The comparison results for the HV5 hardness scale are viewed as additional information, since up to today no CCM key comparisons on this scale have yet been carried out. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Final report of the regional key comparison EURAMET.M.G-K1: European Comparison of Absolute Gravimeters ECAG-2011

    NASA Astrophysics Data System (ADS)

    Francis, Olivier; Klein, Gilbert; Baumann, Henri; Dando, Nicolas; Tracey, Ray; Ullrich, Christian; Castelein, Stefaan; Hua, Hu; Kang, Wu; Chongyang, Shen; Songbo, Xuan; Hongbo, Tan; Zhengyuan, Li; Pálinkás, Vojtech; Kostelecký, Jakub; Mäkinen, Jaakko; Näränen, Jyri; Merlet, Sébastien; Farah, Tristan; Guerlin, Christine; Pereira Dos Santos, Franck; Le Moigne, Nicolas; Champollion, Cédric; Deville, Sabrina; Timmen, Ludger; Falk, Reinhard; Wilmes, Herbert; Iacovone, Domenico; Baccaro, Francesco; Germak, Alessandro; Biolcati, Emanuele; Krynski, Jan; Sekowski, Marcin; Olszak, Tomasz; Pachuta, Andrzej; Agren, Jonas; Engfeldt, Andreas; Reudink, René; Inacio, Pedro; McLaughlin, Daniel; Shannon, Geoff; Eckl, Marc; Wilkins, Tim; van Westrum, Derek; Billson, Ryan

    2012-01-01

    During November 2011 a EURAMET key comparison of absolute gravimeters was organized in the Underground Laboratory for Geodynamics in Walferdange, Luxemburg. The comparison assembled 22 participants coming from 16 countries and four different continents. The comparison was divided into two parts: a key comparison that included six National Metrology Institutes or Designated Institutes, and a pilot study including all participants. The global result given by the pilot study confirms that all instruments are absolutely coherent with each other. The results obtained in the key comparison confirm a good agreement between the NMI instruments. Finally, a link to ICAG-2009 shows also that the NMI gravimeters are stable in time. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report of the key comparison of APMP.AUV.V-K2

    NASA Astrophysics Data System (ADS)

    Usuda, Takashi; Ota, Akihiro; Nozato, Hideaki; Ishigami, Tamio; Kokuyama, Wataru; Plangsangmas, Virat; Rattanangkul, Pairoj; Yih Tsuei, Kuang; Huang, Yu-Chung; Chee Keong, Chan; Shan, Cui

    2017-01-01

    A key comparison of vibration acceleration APMP.AUV.V-K2, which is an upgrade from APMP.AUV.V-K1.1, has been made within the Asia Pacific Metrology Programme (APMP) to include three national laboratories; the CMS-ITRI (Chinese Taipei), the NIMT (Thailand) and the A*Star (Singapore). One pilot laboratory, the NMIJ (Japan), participated to link the RMO APMP results to the CIPM CC key comparison (CCAUV.V-K2), according to the decision of the CCAUV10/D7 during the 10th CCAUV meeting. The admissible acceleration amplitude ranges from 10 m/s2 to 200 m/s2 over the frequency range from 40 Hz to 5 kHz. The RMO APMP results demonstrate the agreement with the key comparison reference value of CCAUV.V-K2 within the expanded uncertainties considering the armature effect of vibration exciter in a high-frequency range. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII (December 2014)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2015-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Final report on CCM key comparison CCM.D-K2: Comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Jacques, Claude; Zelenka, Zoltán; Fujii, Ken-ichi; Kuramoto, Naoki; Chang, Kyung-Ho; Lee, Yong Jae; Becerra, Luis Omar; Domostroeva, Natalia

    2013-01-01

    The results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10-5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database

  11. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII, March 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NPL, April 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Sweeney, Bryan; Quincey, Paul

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone standard of the United Kingdom maintained by the National Physical Laboratory (NPL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with VSL, September 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Heikens, Dita; van der Veen, Adrian

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Netherlands maintained by the Van Swinden (VSL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NIST, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Hodges, Joe; Norris, James E.

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the National Institute of Standards and Technology (NIST) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with INECC, September 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Fentanes, Oscar; Benítez, Ángeles; Ordoñez, Daniel

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of Mexico maintained by the National Institute of Ecology and Climate Change (INECC) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Bilateral key comparison on luminous flux COOMET.PR-K4.1. final report

    NASA Astrophysics Data System (ADS)

    Huriev, M.; Khlevnoy, B.; Tolstykh, G.; Ivashin, E.; Gorchkova, T.

    2017-01-01

    This report describes an international bilateral key comparison on luminous flux of tungsten lamps between the National Scientific Centre 'Institute of Metrology' (NSC 'IM', Ukraine) and All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI, Russia). The comparison is intended to determine the Degrees of Equivalence (DoE) for NSC 'IM' and the associated expanded uncertainty. VNIIOFI acts as a laboratory, providing the link to the comparison CCPR-K4. The comparison used a set of tungsten incandescent lamps as a transfer standard with a luminous flux of approximately 3800 lm. The determined DoE of NSC 'IM' is -0.94% with an expanded uncertainty (k = 2) of 1.05%. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report, on-going key comparison BIPM.QM-K1: ozone at ambient level, comparison with DMDM, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, J.; Moussay, P.; Wielgosz, R.; Bebic, J.; Norris, J. E.; Guenther, F.

    2016-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Directorate of Measures and Precious Metals (DMDM) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NMISA, June 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Ntsasa, Napo G.; Tshilongo, James; Mphaphuli, Gumani E.; Norris, James E.; Hodges, Joseph T.

    2018-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of South Africa maintained by the National Metrology Institute of South Africa (NMISA) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2010)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2011-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2012)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2013-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Final report of the APMP water flow key comparison: APMP.M.FF-K1

    NASA Astrophysics Data System (ADS)

    Lee, Kwang-Bock; Chun, Sejong; Terao, Yoshiya; Thai, Nguyen Hong; Tsair Yang, Cheng; Tao, Meng; Gutkin, Mikhail B.

    2011-01-01

    numbers of equivalence showed values less than 1, indicating equivalence. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. KEY COMPARISON: Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

    NASA Astrophysics Data System (ADS)

    Hung, Chen-Chuan; Jian, Wu; Changpan, Tawat

    2009-01-01

    This report describes the key comparison APMP.M.P-K6.1 among the three national metrology institutes, Center for Measurement Standards-ITRI (CMS-ITRI, Taiwan), SPRING Singapore and National Institute of Metrology (NIMT), in the pressure range from 20 kPa to 105 kPa in gas media and gauge mode executed during the period April 2003 to April 2004. This comparison was conducted by CMS-ITRI and was based on the calibration procedure of APMP pneumatic pressure comparison APMP.M.P-K6. We intended to link to the CCM.P-K6 key comparison through the APMP.M.P-K6 key comparison by using the proposed linkage method in the APMP.M.P-K6 key comparison to determine a linking factor that can transform the quantities measured in the APMP.M.P-K6.1 key comparison. All three participating institutes used pneumatic piston gauges as their pressure standards. The Ruska 2465 gas-operated piston-cylinder assembly TL-1409 used as transfer standard offered by CMS-ITRI was calibrated three times by the pilot institute during the comparison period and showed that it was very stable after evaluation. The comparison was conducted on the basis of cross-float experiments to determine the effective area of transfer standards from the national standards of three institutes. The comparison results (as shown in Table 6) were equivalent to the CCM.P-K6 comparison and the relative bilateral degrees of equivalence between two laboratories were smaller than 39.7 × 10-6 from 20 kPa to 105 kPa. These results showed all participating institutes measuring the same quantity in the whole pressure range lay within their expanded uncertainty with confidence level 95%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with CMS-ITRI, June 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Lin, Tsai-Yin; Norris, James E.; Hodges, Joseph T.

    2017-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the ITRI Center for Measurement Standards (CMS-ITRI) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on the key comparison CCPR-K5: Spectral diffuse reflectance

    NASA Astrophysics Data System (ADS)

    Nadal, Maria; Eckerle, Kenneth L.; Early, Edward A.; Ohno, Yoshi

    2013-01-01

    shows overall good agreement among all participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. KEY COMPARISON: Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Kurupakorn, C.; Fletcher, N.; Stock, M.

    2010-01-01

    This report describes the results obtained from a NIMT (Thailand)-BIPM bilateral comparison of 10 kΩ resistance standards in 2009. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMIT and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was smaller than the uncertainty arising from the calibrations. The mean difference between the NIMT and the BIPM calibrations was found to be significantly larger than the expanded uncertainty (k = 2) of the comparison. However, this exercise allowed previously undetected sources of errors to be detected in the NIMT facility. A new bilateral comparison can be organized as soon as these problems are fixed. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. KEY COMPARISON: Final report of comparison of the calibrations of hydrometers for liquid density determination between SIM laboratories: SIM.M.D-K4

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar

    2009-01-01

    This SIM comparison on the calibration of high accuracy hydrometers was carried out within fourteen laboratories in the density range from 600 kg/m3 to 1300 kg/m3 in order to evaluate the degree of equivalence among participant laboratories. This key comparison anticipates the planned key comparison CCM.D-K4, and is intended to be linked with CCM.D-K4 when results are available. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Final report on key comparison CCQM-K100: Analysis of copper in ethanol

    NASA Astrophysics Data System (ADS)

    Zhou, Tao; Kakoulides, Elias; Zhu, Yanbei; Jaehrling, Reinhard; Rienitz, Olaf; Saxby, David; Phukphatthanachai, Pranee; Yafa, Charun; Labarraque, Guillaume; Cankur, Oktay; Can, Süleyman Z.; Konopelko, Leonid A.; Kustikov, Yu A.; Caciano de Sena, Rodrigo; Marques Rodrigues, Janaina; Fonseca Sarmanho, Gabriel; Fortunato de Carvalho Rocha, Werickson; dos Reis, Lindomar Augusto

    2014-01-01

    The increase in renewable sources in the energy matrix of the countries is an effort to reduce dependency on crude oil and the environmental impacts associated with its use. In order to help overcome the lack of widely accepted quality standards for fuel ethanol and to guarantee its competitiveness in the international trade market, the NMIs have been working to develop certified reference materials for bio-fuels and measurement methods. Inorganic impurities such as Cu, Na and Fe may be present in the fuel ethanol and their presence is associated with corrosion and the formation of oxide deposits in some engine parts. The key comparison CCQM-K100 was carried out under the auspices of the Inorganic Analysis Working Group (IAWG) and the coordination of the National Institute of Metrology, Quality and Technology (INMETRO). The objective of this key comparison was to compare the measurement capabilities of the participants for the determination of Cu in fuel ethanol. Ten NMIs participated in this exercise and most of them used the isotopic dilution method for determining the amount of Cu. The median was chosen as key comparison reference value (KCRV). The assigned KCRV for the Cu content was 0.3589 µg/g with a combined standard uncertainty of 0.0014 µg/g. In general, there is a good agreement among the participants' results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. KEY COMPARISON: Final report on CCQM-K57: Chemical composition of clay

    NASA Astrophysics Data System (ADS)

    Salas, Antonio; Ramírez, Estele

    2009-01-01

    After the successful completion of the pilot study, CCQM-P65 [1], the Inorganic Analysis Working Group of CCQM agreed to conduct key comparison CCQM-K57, Chemical composition of clay, in Paris, April 2006. The natural mass fraction levels of five elements—Si, Ca, Fe, Al and Mg—were measured and reported as oxides in clay. Six national metrology institutes participated in CCQM K57, and CENAM (Querétaro, Mexico) coordinated. The methods employed were isotope dilution mass spectrometry (IDMS), inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-optical emission spectrometry (ICP-OES) using the dehydration method and condensation method, gravimetric analysis, neutron activation analysis (NAA), prompt gamma activation analysis (PGAA) and x-ray fluorescence spectrometry (XRF) with the reconstitution method and external calibration. This final report presents the capability of the participant institutes, based on the KCRV, which was approved at the IAWG spring meeting in 2008, and the equivalence statements regarding the KCRV, approved at its autumn meeting. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Final report of the key comparison APMP.QM-K91: APMP comparison on pH measurement of phthalate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Ketrin, Rosi; Nuryatini; Thanh, Ngo Huy; Truong Chinh, Nguyen; Vospelova, Alena; Bastkowski, Frank; Sander, Beatrice; Matzke, Jessica; Prokunin, Sergey; Frolov, Dmitry; Aprelev, Alexey; Dobrovolskiy, Vladimir; Uysal, Emrah; Liv, Lokman; Velina Lara-Manzano, Judith; Montero-Ruiz, Jazmin; Ortiz-Aparicio, JosÉ Luis; Ticona Canaza, Galia; Anuar Mohd Amin, Khirul; Abd Kadir, Haslina; Bakovets, Nickolay; Wong, Siu-Kay; Lam, Wai-Hing

    2017-01-01

    The APMP.QM-K91 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phthalate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan at the APMP-TCQM meeting held September 22-23, 2014. After approval by TCQM, the comparison has been conducted by NMIJ. The comparison is a key comparison following CCQM-K91. The comparison material was a phthalate buffer of pH around 4.0 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the third APMP key comparison on pH measurement and the fifth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006, APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011 and APMP.QM-K19/APMP.QM-P25 (a borate buffer) in 2013-2014. The results can be used further by any participant to support its CMC claim at least for a phthalate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report of the key comparison APMP.QM-K9: APMP comparison on pH measurement of phosphate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Ohata, Masaki; Cherdchu, Chainarong; Tangpaisarnkul, Nongluck

    2011-01-01

    The APMP.QM-K9 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phosphate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan, NMIJ, and the National Institute of Metrology of Thailand, NIMT, in August 2009. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K9, CCQM-K9.1 and CCQM-K9.2. The comparison material was a phosphate buffer of pH around 6.86 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the first APMP key comparison on pH measurement and the third APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004 and APMP.QM-P09 (a phthalate buffer) in 2006. The results can be used further by any participant to support its CMC claim for a phosphate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the temperature(s) used or the full temperature range between 15 °C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. KEY COMPARISON: Final Report on CCT-K7: Key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Stock, M.; Solve, S.; del Campo, D.; Chimenti, V.; Méndez-Lango, E.; Liedberg, H.; Steur, P. P. M.; Marcarino, P.; Dematteis, R.; Filipe, E.; Lobo, I.; Kang, K. H.; Gam, K. S.; Kim, Y.-G.; Renaot, E.; Bonnier, G.; Valin, M.; White, R.; Dransfield, T. D.; Duan, Y.; Xiaoke, Y.; Strouse, G.; Ballico, M.; Sukkar, D.; Arai, M.; Mans, A.; de Groot, M.; Kerkhof, O.; Rusby, R.; Gray, J.; Head, D.; Hill, K.; Tegeler, E.; Noatsch, U.; Duris, S.; Kho, H. Y.; Ugur, S.; Pokhodun, A.; Gerasimov, S. F.

    2006-01-01

    accepted this recommendation and the next edition of the SI brochure will include this specification. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Final report on APMP.T-K7 key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Tsai, S. F.; White, R.; Tamba, J.; Yamazawa, K.; Ho, M. K.; Tsui, C. M.; Zaid, G.; Achmadi, A.; Gam, K. S.; Othman, H.; Ali, N. M.; Yuan, K. H.; Shaochun, Y.; Liedberg, H.; Yaokulbodee, C.

    2016-01-01

    APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report on key comparison CCQM-K81: Chloramphenicol in pig muscle

    NASA Astrophysics Data System (ADS)

    Polzer, Joachim; Henrion, Andre; Gowik, Petra

    2013-01-01

    analyte content in reconstituted muscle material). Although very different sample preparation techniques (different pre-treatments, defattening steps, cartridges, solvents) as well as different analytical techniques (LC-MSMS, GC-MS, different instruments, columns, eluents) were applied to detect chloramphenicol at a very low concentration level, a KCRV of 0.267 ng/g with a satisfying expanded uncertainty of 17.4% was ascertained. Two of the reported results were not eligible to be used in establishing the KCRV; anyhow the KCRV as estimated from just the eligible results agrees very well with the additional results. With respect to legal requirements for quantitative methods for residue control in food the key comparison results prove the capabilities of the laboratories to fulfil these settings with highest precision and to provide calibration and measurement services to residue control laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report on key comparison COOMET.QM-K36 (Project COOMET 540/UA/11) 'Electrolytic Conductivity 0,5 S/m'

    NASA Astrophysics Data System (ADS)

    Gavrilkin, V.; Prokopenko, L.; Bakovec, N.; Zolotorevich, E.; Suvorov, V.; Ovchinnikov, Yu; Pilishvili, T.; Buleishvili, M.; Zhasanbaeva, B.; Aytzhatova, G.; Ticona, G.; Vyskocil, L.

    2015-01-01

    The COOMET.QM-K36 key comparison 'Electrolytic conductivity: 0.5 S/m' is a comparison in the field of electrolytic conductivity measurements conducted by COOMET and carried out in 2012. It used a solution of KCl in water and the results are connected to those of the CCQM key comparison CCQM-K36.a through common participation of VNIIFTRI (Russia), SMU (Slovakia) and Ukrmetrteststandart (Ukraine). The purpose of this key comparison was to establish the equivalence of measurements of electrolytic conductivity performed at the National Metrology Institutes of COOMET member states for the value of 0.5 S/m. The results can be used to support the CMCs claims over the range of 0.1 S/m to 1.3 S/m. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. KEY COMPARISON: Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Giera, Janine; Fraga, Isabel C.; Tønnes Jakobsen, Pia; Jensen, Hans D.; Hyllested, Peter; Karpov, Oleg; Kutovoy, Viatcheslav; Nakamura, Susumu; Vospelova, Alena; Zvezdina, Valentina

    2008-01-01

    CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were 15 °C, 25 °C, 37 °C. CCQM-K9.2, CCQM-K.9 and the first supplementary comparison CCQM-K9.1 [5] are activities of the Electrochemical Working Group (EAWG) of the CCQM. All three comparisons were coordinated by the PTB, Germany. The Danish Primary Laboratory (DPL) successfully took part in the CCQM-K9. Meanwhile the primary set-up for pH in Denmark moved from DPL affiliated to Radiometer Medical to DFM, Denmark. The subsequent comparison allows assessing the degree of equivalence for the measurement of pH at DFM after the move. Due to the interest of other laboratories in demonstrating their progress in pH measurements on the primary level the CCQM-K9.2 supplementary comparison was extended to other participants than DFM, namely NMIJ, VNIIFTRI, INMETRO and CMI. The reported quantity for CCQM-K9.2 was not the pH of the sample but the acidity function at zero chloride molality (see chapter 12). To calculate the pH value from the acidity function it is necessary to know the ionic strength of the sample buffer solution, which was undisclosed by the coordinator. With the exception of the Czech Metrology Institute, CMI, good agreement in the determined acidity function is found between the participants. The results reported by DFM and by PTB agree within their measurement uncertainty at all measurement temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report

  18. KEY COMPARISON: Final report on CCQM-K44: Trace elements in sewage sludge

    NASA Astrophysics Data System (ADS)

    Aregbe, Y.; Taylor, P. D. P.

    2009-01-01

    CCQM-K44 was an activity of the Inorganic Analysis Working Group (IAWG) of CCQM and was coordinated by the Joint Research Centre-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) of the European Commission (EC). In CCQM-K44 the amount contents of Cd, Cr, Cu, Pb, Hg, Ni and Zn in sewage sludge were the measurands under investigation. Results were reported by six national metrology institutes (NMIs). During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and agreed on. The final report was submitted in June 2006. After the final report had been submitted to the CCQM in June 2006 the coordinating laboratory was informed that MIRS/IJS was not a designated institute and therefore could not represent the Slovenian NMI in CCQM-K44. This was contrary to what MIRS confirmed to the coordinating laboratory at the beginning of CCQM-K44. After several discussions between MIRS and the CCQM the coordinating laboratory was asked to amend the final report accordingly. In this revised version of the CCQM-K44 final report the results of MIRS/IJS were taken out of CCQM-K44 and included in the pilot study CCQM-P70, which was organised in parallel to CCQM-K44. Due to the limited number of participants compared to previous key comparisons the mixture model median (MM-median) of all reported results could not be applied as KCRV for all the measurands. During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and first agreed on. As a result the final report and degrees of equivalence were finalised and submitted to the CCQM. Subsequent discussions between the IAWG and the CCQM were held, resulting in a different approach as proposed by the coordinating laboratory. Particularly Maurice Cox from NPL recommended the weighted mean and its standard uncertainty (k = 1) as KCRV

  19. Final report on COOMET Vickers PTB/VNIIFTRI key comparison (COOMET.M.H-K1.b and COOMET.M.H-K1.c)

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Herrmann, K.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales of two National Metrology Institutes—PTB and VNIIFTRI. The pilot laboratory was PTB, which was the linking institute with the key comparison reference values of CCM.H-K1. In the key comparison two sets of hardness reference blocks for the Vickers hardness scales HV1 and HV30, each consisting of three hardness reference blocks with the hardness levels 240 HV, 540 HV and 840 HV, are used. The same hardness reference blocks were used previously in the key comparison CCM.H-K1. The measurement results and uncertainty assessments, announced by VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. KEY COMPARISON: CCQM-K21 Key Comparison Determination of pp’-DDT in fish oil

    NASA Astrophysics Data System (ADS)

    Webb, K. S.; Carter, D.; Wolff Briche, C. S. J.

    2003-01-01

    A key comparison on the determination of (pp'-dichlorodiphenyl) trichloroethane (pp'-DDT) in a fish oil matrix has been successfully completed. Nine NMIs participated in this key comparison and used the technique of isotope dilution gas-chromatography mass spectrometry (ID/GC/MS) for the determinations. Two samples (A and B) of fish oil were distributed to participants, each gravimetrically spiked with pp'-DDT. The KCRV for Sample A is 0.0743 +/- 0.0020 µg g-1 and that of Sample B is 0.1655 +/- 0.0014 µg g-1 of pp'-DDT in fish oil. The results for Sample A showed a RSD of 3.5%, the RSD for Sample B was within 1%. These results were an improvement over those of the corresponding pilot study (CCQM-P21), where at a mass fraction of pp'-DDT in fish oil of 0.311 µg g-1 the RSD was 2.6%. The compound pp'-DDT is a typical organochlorine pesticide and this key comparison has shown that NMIs have the ability to measure such compounds at levels typically found in the environment. The compound (pp'-dichlorodiphenyl) dichloroethylene (pp'-DDE), a metabolite of pp'-DDT, was the subject of a previous key comparison (CCQM-K5). The compound pp'-DDT is technically more challenging than that of pp'-DDE since it can decompose during the measurement procedure. Consequently the success of this key comparison, combined with that of CCQM-K5 demonstrates a broad measurement capability by NMIs for organochlorine compounds in the environment. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  1. KEY COMPARISON: Final report of EUROMET Project 696: pH determination of a phthalate buffer

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Charlet, Philippe; Eberhard, Ralf; Karpov, Oleg V.; Philippe, Rachel; Rivier, Cedric; Maximov, Igor; Sudmeier, Uwe

    2005-01-01

    The EUROMET project 696, a trilateral comparison between PTB, Germany, LNE, France and VNIIFTRI, Russia was performed in order to demonstrate and document the capability of the participants to measure the pH of a phthalate buffer by the primary measurement procedure for pH. Good agreement of the reported results was observed. The sample was very similar to the one used in the comparison CCQM-K17. PTB acts as pilot laboratory in CCQM-K17 and in EUROMET 696. This comparison allows one to link the results obtained by LNE to the CCQM-K17 key comparison through the degree of equivalence of PTB. On the other hand, the discrepancy between measured pH values at the VNIIFTRI and PTB for the same type of buffer solution decreased, as compared with a bilateral comparison in 1997. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  2. Final report on EUROMET key comparison EUROMET.M.D-K2 (EUROMET 627) "Comparison of density determinations of liquid samples"

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Heinonen, Martti; Gosset, André; Zelenka, Zoltán; Lorefice, Salvatore; Hellerud, Kristen; Durlik, Hanna; Jordaan, Werner; Field, Ireen

    2016-01-01

    The results of the key comparison EUROMET 627 (EUROMET.M.D-K2) are presented. This project covered the density measurements of three liquids: dodecane, water and an oil of high viscosity measured at 15 °C, 20 °C and 40 °C. Seven European metrology laboratories and the South African laboratory CSIR-NML (now: NMISA) measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards between 04 October 2001 and 18 December 2001. The stability and homogeneity of the liquids were investigated by the pilot laboratory PTB. The results generally show good agreement among the participants. Only for the simple Mohr-Westphal balances do the uncertainties seem to be underestimated by the laboratories. Furthermore, the measurement of high-viscosity oil was difficult for some laboratories. Nevertheless, the five laboratories PTB/DE, BNM/FR (now: LNE/FR), OMH/HU (now: MKEH/HU), IMGC/IT (now: INRIM/IT) and GUM/PL agree with each other for stated uncertainties of 0.05 kg/m3 or less. This satisfies the current needs of customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. No reference values were calculated since the subsequent CCM key comparison CCM.D-K2 had a different scope and the EUROMET 627 comparison was soon superseded by the EURAMET 1019 (EURAMET.M.D-K2) comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report of CCAUV.V-K3: key comparison in the field of acceleration on the complex charge sensitivity

    NASA Astrophysics Data System (ADS)

    Qiao, Sun; Lifeng, Yang; Bartoli, Claire; Veldman, Ian; Ripper, Gustavo P.; Bruns, Thomas; Rask Licht, Torben; Kolasa, Joanna; Hof, Christian; Silva Pineda, Guillermo; Dickinson, Laurence; Ota, Akihiro; Cheung, Wan Sup; Yankovsky, Alexander; Shan, Cui

    2017-01-01

    This is the final report for CIPM key comparison CCAUV.V-K3 in the area of 'vibration' (quantity of acceleration). The aim of this comparison was to measure the voltage sensitivity of one accelerometer standard set with primary means at 27 frequencies from 0.1 Hz to 40 Hz. Fourteen Metrology Institutes from five RMOs have participated in the comparison with National Institute of Metrology, P.R. China as pilot lab and Laboratoire National de Métrologie et d'Essais and National Metrology Institute of South Africa as co-pilot labs. One quartz-flexure servo accelerometer of single-ended type and a signal conditioner was circulated among the participants. All but one of the participating laboratories provided their calibration results, which were mostly consistent within their declared expanded uncertainties for magnitude results. Only two participants failed to contribute to the KCRV values calculated for five frequencies. For phase shift, three participants could not contribute to the calculation of the KCRV values in a total of sixteen frequencies. This first low-frequency vibration key comparison revealed the current calibration capabilities of the fourteen participants of five RMOs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on the key comparison of hydrocarbon liquid flow: CCM.FF-K2.2015

    NASA Astrophysics Data System (ADS)

    Shimada, T.; Bittner-Rohrhofer, K.; Medina López, V. J.; Arias, R.; Su, C.-M.; Chen, I.-C.; Ribere, F.; Rowan, L.; Dignan, S.

    2016-01-01

    Seven laboratories: BEV (Austria), CENAM (Mexico), CMS (Chinese-Taipei), LNE-TRAPIL (France), NEL (United Kingdom), NMIA (Australia), and the pilot lab NMIJ (Japan), participated in the key comparison CCM.FF-K2.2015 for hydrocarbon flow measurement. A screw type positive displacement flow meter was selected as a transfer standard. The calibration stability of the transfer standard was evaluated from repeated measurements by NMIJ and showed standard reproducibility of 0.0035 %. The transfer standard was also thoroughly tested for sensitivity to temperature, viscosity, pressure, and other effects. The uncertainty due to the transfer standard of 0.0080 % was less than the quoted uncertainties of the participants. The key comparison reference values (KCRVs) at Reynolds number of 70 000 and 300 000 were obtained as the weighted mean from the calibration results, and the KCRV at Reynolds number of 100 000 was obtained as the median by using the Monte Carlo method according to Cox's procedure B, since the consistency check at Reynolds number of 100 000 failed at the 95 % confidence level. All participant results selected to determine the KCRVs have En values which show consistency with the evaluated KCRVs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. KEY COMPARISON: Final report on bilateral comparison CCEM.RF-K9.1: Thermal noise standards at 12.4 GHz, 13.5 GHz, 15 GHz and 17.5 GHz

    NASA Astrophysics Data System (ADS)

    Allal, Djamel

    2009-01-01

    A bilateral comparison subsequent to key comparison CCEM.RF-K9 was decided between VNIIFTRI and PTB. It was registered into the BIPM KCDB under the identifier CCEM.RF-K9.1. The results of this comparison were gathered by the pilot laboratory of comparison CCEM.RF-K9, the LNE, and a very good agreement was found between the two participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Final report on CIPM key comparison CCM.FF-K6.2011: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John

    2014-01-01

    The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. KEY COMPARISON: Final report of the CCQM-K56: Ca, Fe, Zn and Cu in whole fat soybean powder

    NASA Astrophysics Data System (ADS)

    Liandi, Ma; Qian, Wang

    2010-01-01

    The CCQM-K56 key comparison was organized by the Inorganic Analysis Working Group (IAWG) of CCQM as a follow-up to completed pilot study CCQM-P64 to test the abilities of national metrology institutes to measure the amount content of nutritious elements in whole fat soybean powder. A pilot study CCQM-P64.1 was conducted in parallel with this key comparison. The National Institute of Metrology (NIM), P. R. China, acted as the coordinating laboratory. Eleven NIMs participated in CCQM-K56. Four elements - Ca, Fe, Zn and Cu - in different concentration levels have been studied. Different measurement methods (IDMS, ICP-MS, ICP-OES, AAS and INAA) and the microwave digestion method were used. The agreement of the results of CCQM-K56 is very good, and obviously better than that of the original P64. It shows that the capability of all of the participants had been promoted from the original pilot study to this key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Final report on the key comparison CCM.P-K4.2012 in absolute pressure from 1 Pa to 10 kPa

    NASA Astrophysics Data System (ADS)

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. KEY COMPARISON Final report on APMP.EM-K6.a: APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty

    NASA Astrophysics Data System (ADS)

    Budovsky, Ilya

    2010-01-01

    The APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty, APMP.EM-K6a, started in 2000 and concluded in 2003. This comparison has offered the same range and frequencies as the key comparison CCEM-K6a with the view of providing the National Metrology Institutes (NMIs) of the APMP member economies with an opportunity to link the values of their standards for ac-dc transfer difference to the international reference values. The ac-dc difference of the travelling standard was measured with 3 V applied at standard frequencies of 1 kHz, 20 kHz, 100 kHz and 1 MHz, and optional frequencies of 50 kHz and 500 kHz. The travelling standard has not been damaged and has shown excellent stability. The results submitted by the overwhelming majority of the participants lie well within the reported uncertainty. At the standard frequencies the results have been linked to those of the CCEM-K6a key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Final report on SIM Regional Key Comparison SIM.L-K1.2007: Calibration of gauge blocks by optical interferometry

    NASA Astrophysics Data System (ADS)

    Colín, C.; Viliesid, M.; Chaudhary, K. P.; Decker, J.; Dvorácek, F.; Franca, R.; Ilieff, S.; Rodríguez, J.; Stoup, J.

    2012-01-01

    This Key Comparison of gauge blocks (GB) calibration by optical interferometry was carried out to support this Calibration and Measurement Capability (CMC) of the National Measurement Institutes (NMI) from the SIM Region for this specific service and for those that rely on this kind of technique as required by the Mutual Recognition Arrangement (MRA). It provides evidence of the participant's technical competence and supports the uncertainties they state in their CMC. It is a Regional Key Comparison and should be linked to the upper level corresponding comparison CCL-K1. The comparison had nine participants, five from the SIM Region—NRC-CNRC, Canada; NIST, USA; CENAM, Mexico; INMETRO, Brazil; and INTI, Argentina— and four from other regions—CMI, Czech Rep.; CEM, Spain; NPLI, India; and NMISA South Africa. It included the circulation of fourteen GB—seven steel GB and seven ceramic GB. The circulation of the artifacts started on 2007-11-01 and ended on 2010-04-25. Some additional time was required to publish the results as the same artifacts were used thereafter for comparison SIM.L-S6, Calibration of GB by mechanical comparison, and the results could not be disclosed until the participants of the second circulation loop had sent their results. The final report of this comparison was sent out for review in May 2012 and the final version was approved in August 2012. The behavior of the artifacts throughout the circulation was good and therefore the results obtained were judged technically valid. The reference value was taken as arithmetic mean of the largest subset of consistent results. Most of participates obtained results in good agreement with the reference values with a few exceptions mentioned in the report. The corresponding NMIs are responsible for identifying the causes and taking corrective action. This makes the present comparison exercise valid to support the CMC claims of the participants in GB calibration by optical interferometry. Main text. To

  11. Final report on APMP.T-K7.1 key comparison of water triple point cells, bilateral NMIJ-VMI

    NASA Astrophysics Data System (ADS)

    Yamazawa, Kazuaki; Nakano, Tohru; Thanh Binh, Pham

    2018-01-01

    APMP.T-K7.1, was held from July 2014 to May 2015 to compare the national realizations of the water triple point between NMIJ (Japan) and VMI (Vietnam). To reach the objective, VMI sent a transfer cell to NMIJ and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the NMIJ and at the VMI, and aims to link the results of APMP.T-K7.1 to APMP.T-K7 and CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. KEY COMPARISON: Final report on CCEM key comparison CCEM.RF-K10.CL (GT-RF/99-2) 'Power in 50 Ω coaxial lines, frequency: 50 MHz to 26 GHz' measurement techniques and results

    NASA Astrophysics Data System (ADS)

    Janik, Dieter; Inoue, T.; Michaud, A.

    2006-01-01

    This report summarizes the results and the measuring methods of an international key comparison between twelve national metrology institutes (NMIs) and is concerning the calibration factor of RF power sensors in the coaxial 3.5 mm line for frequencies up to 26 GHz. Two RF power travelling standards fitted with male PC 3.5 mm connectors were measured at seven frequencies. The following NMIs participated: NMIJ (Japan), NRC (Canada), NIST (USA), METAS (Switzerland), CSIR-NML (South Africa), NMIA (Australia), NPL (UK), SiQ (Slovenia), IEN (Italy), VNIIFTRI (Russian Federation), SPRING (Singapore) and PTB (Germany), as the pilot laboratory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Final report on key comparison CCAUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Avison, Janine; Barham, Richard

    2014-01-01

    This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report on key comparison EURAMET.M.P-K13 in the range 50 MPa to 500 MPa of hydraulic gauge pressure

    NASA Astrophysics Data System (ADS)

    Kocas, I.; Sabuga, W.; Bergoglio, M.; Eltaweel, A.; Korasie, C.; Farar, P.; Setina, J.; Waller, B.; Durgut, Y.

    2015-01-01

    The regional key comparison EURAMET.M.P-K13 for pressure measurements in liquid media from 50 MPa to 500 MPa was piloted by the TÜBİTAK UME Pressure Group Laboratories, Turkey. The transfer standard was a DH-Budenberg pressure balance with a free deformation piston-cylinder unit of 2 mm2 nominal effective area. Six laboratories from the EURAMET region, namely PTB, INRIM, SMU, IMT, NPL and UME, and two laboratories from the AFRIMETS region, NIS and NMISA participated in this comparison. Participant laboratories and countries are given in the bottom of the page. PTB participated in this comparison to provide a link to corresponding 500 MPa CCM key comparison CCM.P-K13. The results of all participants excepting NMISA and NPL were found to be consistent with the reference value of the actual comparison and of CCM.P-K13 within their claimed uncertainties (k = 2), at all pressures. Compared in pairs all laboratories with exception of NPL and NMISA demonstrate their agreement with each other within the expanded uncertainties (k = 2) at all pressures. The results are therefore considered to be satisfactory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. KEY COMPARISON: Final report on Key Comparison APMP.SIM.M.P-K1c: Bilateral comparison between NIST (USA) and NPLI (India) in the pneumatic pressure region 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Driver, R. Gregory; Olson, Douglas A.; Dilawar, Nita; Bandyopadhyay, A. K.

    2007-01-01

    We report the results of a bilateral comparison of pressure measurement between NIST and NPLI using a piston gauge transfer standard (TS), designated as NPLI-4, over the range of nominal applied pressure 0.4 MPa to 4.0 MPa. This TS was cross-floated against the laboratory secondary standard designated as PG13 at NIST, USA and against NPLI-8 at NPLI, India. The nominal pressure points of the bilateral comparison were (0.4, 0.8, 1.2, 1.6, 2.0, 2.4, 2.8, 3.2, 3.6 and 4.0) MPa, respectively. The comparison was performed in both the institutes in identical pressure cycles in increasing pressures. The comparison data were analysed in terms of the effective area [Ap (mm2)] as a function pressure [p (MPa)] of the TS at the above-mentioned pressures. We have also estimated the zero-pressure effective area [A0 (mm2)] and the pressure distortion coefficient [λ (MPa-1)] of the transfer standard. The consistency of the results at every pressure in the range indicates that the laboratory standards used in this comparison are compatible, uniform and can be considered traceable to each other. Finally, the degree of equivalence between NPLI and NIST is 11.4 × 10-6 or better, which is always less than the relative standard uncertainty of the difference (33.6 × 10-6). Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Key comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Buchner, Christian; Zelenka, Zoltan; Kajastie, Heikki; Madec, Tanguy; Wolf, Henning; Vámossy, Csilla; Lorefice, Salvatore; Garberg, Torgunn; Lenard, Elżbieta; Spohr, Isabel; Mares, Gabriela; Spurný, Robert; Lumbreras, Angel; Medina, Nieves; Y Akçadağ, Ümit; Perkin, Michael

    2015-01-01

    Hydrostatic density determination for liquids is mainly performed by laboratories to provide means for calibrating liquid density measuring instruments such as oscillation-type density meters. From 2002 to 2005 the CIPM key comparison CCM.D-K2 'comparison of liquid density standards' was carried out piloted by the PTB. The aim was to compare the results of the density determination by the participating laboratories to support entries to the CMC tables in this sub-field. To provide further laboratories the possibility to support their entries to the CMC tables at the meeting of the EUROMET Working Group on Density in 2007 this comparison was agreed on. BEV (Austria) organized the comparison supported by the PTB (Germany). For the comparison samples of pentadecane, water, tetrachloroethylene and of an oil of high viscosity were measured in the temperature range from 5 °C to 60 °C at atmospheric pressure by hydrostatic weighing. The measurements were completed in 2008. The reference values of the first reports based on the draft of the CCM.D-K2. After the official publication of the CCM.D-K2 the reference values were recalculated and the report was finalised in 2015. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison

    NASA Astrophysics Data System (ADS)

    Newell, D. B.; van Westrum, D.; Francis, O.; Kanney, J.; Liard, J.; Ramirez, A. E.; Lucero, B.; Ellis, B.; Greco, F.; Pistorio, A.; Reudink, R.; Iacovone, D.; Baccaro, F.; Silliker, J.; Wheeler, R. D.; Falk, R.; Ruelke, A.

    2017-01-01

    Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Comparison is key.

    PubMed

    Stone, Mark H; Stenner, A Jackson

    2014-01-01

    Several concepts from Georg Rasch's last papers are discussed. The key one is comparison because Rasch considered the method of comparison fundamental to science. From the role of comparison stems scientific inference made operational by a properly developed frame of reference producing specific objectivity. The exact specifications Rasch outlined for making comparisons are explicated from quotes, and the role of causality derived from making comparisons is also examined. Understanding causality has implications for what can and cannot be produced via Rasch measurement. His simple examples were instructive, but the implications are far reaching upon first establishing the key role of comparison.

  19. CCM key comparison CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.; Lenard, E.; Lee, Y. J.; Lee, W. G.; Madec, T.; Meury, P. A.; Caceres, J.; Santos, C.; Vamossy, C.; Man, J.; Fen, K.; Toda, K.; Wright, J.; Bettin, H.; Toth, H.

    2016-01-01

    This report presents the comparison philosophy, methodology, analysis and the results of the designed CCM.D-K4 key comparison that covered the calibration of high resolution hydrometers for liquid and alcoholometers in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20°C. The main purpose of this comparison was not only to evaluate the degree of equivalence in the calibration of high accuracy hydrometers between NMI participants, but also to link, were it is possible, the results of previous comparisons to Key Comparison Reference Values (KCRVs) of CCM.D-K4. Eleven NMI laboratories took part in the CCM.D-K4 divided in two groups (petals). With the CCM.D-K4 purpose, two similar sets consisting of three hydrometers for liquid density determinations and an alcoholometer were circulated to the NMI participants as a travelling standard in the time interval from January 2011 to April 2012. Twelve Key Comparison Reference Values (KCRVs) for each petal have been obtained at the density values related to the tested density marks of the transfer standards by the results of participants. The KCRVs and corresponding uncertainties were calculated by the weighted mean in the case of consistent results, otherwise the median was used. The degree of equivalence (DoE) with respect to the corresponding KCRV was determined for each participant and, in this particular comparison, the Weighted Least Squares (WLS) method was used to link the individual DoE of each participant by a continuous function. Significant drift of the transfer standards was not detected. This report also gives instructions on calculating pair-wise degrees of equivalence, with the addition of any information on correlations that may be necessary to estimate more accurately as well as the procedure for linking international comparisons to the CCM.D-K4. Finally an example of linkage to the CCM.D-K4 is given by dealing with the results of the bilateral comparison between INRiM and NMIA, which was

  20. KEY COMPARISON: Key comparison CCQM-K60: Total selenium and selenomethionine in selenised wheat flour

    NASA Astrophysics Data System (ADS)

    Goenaga Infante, Heidi; Sargent, Mike

    2010-01-01

    , illustrating their ability to obtain accurate results for such analytes in a complex food matrix containing approximately 17 mg kg-1 Se. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. Final report on key comparison APMP.M.P-K13 in hydraulic gauge pressure from 50 MPa to 500 MPa

    NASA Astrophysics Data System (ADS)

    Kajikawa, Hiroaki; Kobata, Tokihiko; Yadav, Sanjay; Jian, Wu; Changpan, Tawat; Owen, Neville; Yanhua, Li; Hung, Chen-Chuan; Ginanjar, Gigin; Choi, In-Mook

    2015-01-01

    This report describes the results of a key comparison of hydraulic high-pressure standards at nine National Metrology Institutes (NMIs: NMIJ/AIST, NPLI, NMC/A*STAR, NIMT, NMIA, NIM, CMS/ITRI, KIM-LIPI, and KRISS) within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence in the pressure range from 50 MPa to 500 MPa in gauge mode. The pilot institute was the National Metrology Institute of Japan (NMIJ/AIST). All participating institutes used hydraulic pressure balances as their pressure standards. A set of pressure balance with a free-deformational piston-cylinder assembly was used as the transfer standard. Three piston-cylinder assemblies, only one at a time, were used to complete the measurements in the period from November 2010 to January 2013. Ten participants completed their measurements and reported the pressure-dependent effective areas of the transfer standard at specified pressures with the associated uncertainties. Since one of the participants withdrew its results, the measurement results of the nine participants were finally compared. The results were linked to the CCM.P-K13 reference values through the results of two linking laboratories, NMIJ/AIST and NPLI. The degrees of equivalence were evaluated by the relative deviations of the participants' results from the CCM.P-K13 key comparison reference values, and their associated combined expanded (k=2) uncertainties. The results of all the nine participating NMIs agree with the CCM.P-K13 reference values within their expanded (k=2) uncertainties in the entire pressure range from 50 MPa to 500 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. KEY COMPARISON: Final Report on EUROMET.T-K3: Regional key comparison of the realisations of the ITS-90 from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Renaot, E.; Hermier, Y.; Valin, M.; Bonnier, G.

    2007-01-01

    during a Workshop organized by the pilot in Vienna in April 2005 to use as ERV the weighted mean rather than the simple mean. The differences (TLab - TERV) are presented with the associated uncertainties. Given that the protocol of the comparison contains a detailed description of how the uncertainties are to be calculated, the uncertainty budgets established by the participants seem consistent or, at least, homogeneous. The degrees of equivalence between the participating laboratories (in the same loop or in different loops) are given with their associated uncertainty. Finally, a method for establishing the bilateral equivalence between the participants in CCT-K3 and in EUROMET'T-K3 is proposed. It is recommend to use a group of 'linking laboratories' composed by the pilot and the co-pilots in order to link EUROMET.T-K3 to CCT-K3. The hypothesis is that the mean temperature of the pilot and co-pilot laboratories is the same in EUROMET.T-K3 as it was in CCT-K3. A specific analysis of the pilot's and co-pilot's results shows that even when the results given by one or several members of the 'linking laboratories' are not positioned in the same place as in EUROMET.T-K3 and CCT-K3 the mean calculated for the group is really reproducible. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. KEY COMPARISON: Final report on CCPR K1-a: Spectral irradiance from 250 nm to 2500 nm

    NASA Astrophysics Data System (ADS)

    Woolliams, Emma R.; Fox, Nigel P.; Cox, Maurice G.; Harris, Peter M.; Harrison, Neil J.

    2006-01-01

    spectral region (250 nm to 2500 nm) there were 44 wavelengths at which a comparison was made. These were treated entirely independently and thus the report describes 44 comparisons. For wavelengths from 250 nm to 800 nm (apart from 300 nm) all participants had unilateral degrees of equivalence (DoEs) with values consistent with their uncertainties for a coverage level k = 2. At all other wavelengths (apart from 1400 nm) all participants achieved consistency at the k = 4 level for the unilateral DoEs and the vast majority within k = 3. The results are a significant improvement over those of the previous comparison in 1990, especially considering that the declared uncertainties of most participants have been substantially improved over the intervening decade. These results are evidence of the value of the effort devoted to the development of improved spectral scales (and of the evaluation of their uncertainty) by many NMIs in recent years. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. KEY COMPARISON: Final report on CCQM-K62: Nutrients in infant/adult formula—Vitamins

    NASA Astrophysics Data System (ADS)

    Sharpless, Katherine E.; Rimmer, Catherine A.; Phinney, Karen W.; Nelson, Bryant C.; Duewer, David L.; Wise, Stephen A.; Kim, Byungjoo; Liu, Jun; Huang, Ting; Zhang, Wei

    2010-01-01

    and vitamin A and one of the three results for folic acid was withdrawn, no strong conclusions as to the expected comparability of higher-order vitamin measurements can be established. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    NASA Astrophysics Data System (ADS)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Regional comparison of absolute gravimeters, EURAMET.M.G-K2 key comparison

    NASA Astrophysics Data System (ADS)

    Pálinkáš, V.; Francis, O.; Val'ko, M.; Kostelecký, J.; Van Camp, M.; Castelein, S.; Bilker-Koivula, M.; Näränen, J.; Lothhammer, A.; Falk, R.; Schilling, M.; Timmen, L.; Iacovone, D.; Baccaro, F.; Germak, A.; Biolcati, E.; Origlia, C.; Greco, F.; Pistorio, A.; De Plaen, R.; Klein, G.; Seil, M.; Radinovic, R.; Reudink, R.; Dykowski, P.; Sȩkowski, M.; Próchniewicz, D.; Szpunar, R.; Mojzeš, M.; Jańk, J.; Papčo, J.; Engfeldt, A.; Olsson, P. A.; Smith, V.; van Westrum, D.; Ellis, B.; Lucero, B.

    2017-01-01

    In the framework of the regional EURAMET.M.G-K2 comparison of absolute gravimeters, 17 gravimeters were compared in November 2015. Four gravimeters were from different NMIs and DIs, they were used to link the regional comparison to the CCM.G.K2 by means of linking converter. Combined least-squares adjustments with weighted constraint was used to determine KCRV. Several pilot solutions are presented and compared with the official solution to demonstrate influences of different approaches (e.g. definition of weights and the constraint) on results of the adjustment. In case of the official solution, all the gravimeters are in equivalence with declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. SIM key comparison for luminous flux. SIM.PR-K4

    NASA Astrophysics Data System (ADS)

    Matamoros, Carlos H.; Ohno, Yoshi; Zwinkels, Joanne; Cogno, Jorge A.; Couceiro, Iakyra B.

    2016-01-01

    In compliance with the established BIPM and CCPR policies and guidelines on comparisons, the SIM Photometry and Radiometry Working Group decided to conduct a key comparison on total luminous flux in order to provide an opportunity for its member National Metrology Institutes (NMIs) that did not participate in the CCPR-K4 comparison, to get a link to the reference value obtained for this quantity (the lumen) and to derive the corresponding degrees of equivalence. This SIM.PR-K4 was piloted by Centro Nacional de Metrología (CENAM), the NMI of Mexico and included the participation of five laboratories: CENAM (Mexico), INTI (Argentina), INMETRO (Brazil), NIST (USA, linking lab), and NRC (Canada, linking lab). The comparison, conducted in star type scheme, was run using three to four lamps per participant, and results are given in this report, including the unilateral degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on key comparison APMP.M.P-K3: Absolute pressure measurements in gas from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Yoshida, H.; Arai, K.; Akimichi, H.; Hong, S. S.; Song, H. W.

    2011-01-01

    The results of a key comparison of ultra-high vacuum standards at two national metrology institutes (NMIJ/AIST and KRISS) are reported. This bilateral comparison was carried out from May 2010 to October 2010 within the framework of the Asia-Pacific Metrology Programme (APMP) to determine their degrees of equivalence at pressures in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. The pilot institute was NMIJ/AIST. Two spinning rotor gauges and two hot cathode ionization gauges were used as the transfer standards. NMIJ/AIST used two calibration systems: the dynamic expansion system (NMIJ-DES) and two-stage flow-dividing system (NMIJ-TFS). KRISS used the dynamic expansion system. The transfer standards were sufficiently stable to meet the requirements of the comparison compared with those of previous international comparisons owing to some improvements of the protocol and the transfer standards. The ultra-high vacuum standards of NMIJ/AIST and KRISS were found to be equivalent within their claimed uncertainties in the range from 3 × 10-6 Pa to 9 × 10-5 Pa. The NMIJ-DES results, which have smaller uncertainty than NMIJ-TFS, were transferred to the corresponding CCM key comparison, CCM.P-K3, in the range from 3 × 10-6 Pa to 9 × 10-5 Pa and it is shown that the NMIJ values were equivalent to the CCM key comparison reference value within the claimed uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. SUPPLEMENTARY COMPARISON: Final report on APMP.PR-S1.1: Bilateral comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Huang, Xuebo

    2009-01-01

    In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. KEY COMPARISON: Report of the spectral irradiance comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

    NASA Astrophysics Data System (ADS)

    Ojanen, M.; Shpak, M.; Kärhä, P.; Leecharoen, R.; Ikonen, E.

    2009-01-01

    A bilateral comparison of the spectral irradiance scales between MIKES (Finland) and NIMT (Thailand) was carried out at 22 wavelengths between 290 nm and 900 nm. MIKES acted as the pilot and link to the results of the key comparison CCPR-K1.a. The spectral irradiance values measured by NIMT generally agree with the key comparison reference value within the expanded uncertainty. The only exceptions are results at wavelengths 300 nm, 450 nm and 500 nm, where the ratios between the degree of equivalence (DoE) and the expanded uncertainty of DoE (k = 2) are 1.0, 1.4 and 1.2, respectively. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. Final report on the key comparison, CCM.P-K15 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Arai, Kenta; Bergoglio, Mercede; Fedchak, James A.; Jousten, Karl; Hong, Seung Soo; Torres Guzman, Jorge

    2017-01-01

    The comparison CCM.P-K15 is a key comparison in pressure involving six laboratories in three regional metrological organizations (RMO). The measurand of the comparison is the accommodation coefficient of two spinning rotating gauge characterized in nitrogen from 0.1 mPa up to 1.0 Pa. The two transfer standards were circulated from November 2009 until March 2011. The circulation consisted of three loops, one for each RMO, and a new calibration by the pilot be-tween each loop. The stability of one of the transfer standards was poor and was worse than expected based on the previous history of the transfer standard while the other transfer standard demonstrated good stability while circulated in Europe and America and a fair stability while circulated in Asia. All the participants demonstrated equivalence to the definition of pressure in their respective primary standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. CCM.FF-K3.2011: Final report for the CIPM key comparison of air speed, 0.5 m/s to 40 m/s

    NASA Astrophysics Data System (ADS)

    Müller, Harald; Caré, Isabelle; Lucas, Peter; Pachinger, Dietmar; Kurihara, Noboru; Lishui, Cui; Su, Chun-Min; Shinder, Iosif; Spazzini, Pier Giorgio

    2017-01-01

    The CCM.FF-K3.2011 comparison was organized for the purpose of determination of the degree of equivalence of the national standards for air speed over the range 0.5 m/s to 40 m/s. An ultrasonic anemometer and a Laser Doppler anemometer were used as transfer standards. Nine laboratories from three RMOs participated between July 2013 and July 2015—EURAMET: PTB, Germany; LNE-CETIAT, France; INRIM, Italy; VSL, The Netherlands; E+E, Austria; SIM: NIST, USA; APMP: NMIJ/AIST, Japan; NIM, China; CMS/ITRI, Chinese Taipei. The measurements were provided at ambient conditions. All results of independent participants were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each air speed separately following `procedure A' presented by M G Cox. The degree of equivalence with the KCRV was calculated for each air speed and laboratory. Almost all reported results were consistent with the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report of the key comparison CCQM-K106: Pb, As and Hg measurements in cosmetic (cream)

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Wang, Qian; Yamani, Randa Nasr Ahmed; Shehata, Adel B.; Jacimovic, Radojko; Pavlin, Majda; Horvat, Milena; Tsoi, Y. P.; Tsang, C. K.; Shin, Richard; Chailap, Benjamat; Yafa, Charun; Caciano de Sena, Rodrigo; de Almeida, Marcelo; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Heun Kim, Sook; Konopelko, Leonid; Ari, Betül; Tokman, Nilgün; Rienitz, Olaf; Jaehrling, Reinhard; Pape, Carola

    2015-01-01

    relating to CCQM-K106 was sent to each participant by e-mail, which consisted of technical protocol, results report form and inorganic core capabilities tables. The results were reported as mass faction (mg/kg). Calculation of the uncertainty expressed as a combined standard uncertainty and an expanded uncertainty at 95% confidence. In order to allow a sufficient evaluation of the comparison, the report was required to include a detailed description of the applied method of measurement, information about sample digestion and preparation, information about the reference material used for calibration. The methods of measurement were free to be selected by the participants. For the sample treatment, most of the participants used microwave digestion method. For instrumental determination, a variety of techniques such as ICP-MS, AAS, INAA were adopted by the participants. Most participants choose ID-ICP-MS method to measure Pb and Hg, which showed the better performance in terms of consistency and reliability of the measurement results. The reference mass fraction values and associated uncertainties were calculated by different statistic ways. As the result, the median and uncertainty of median were proposed as the key comparison reference value (KCRV) and its associated key comparison reference uncertainty after removal of suspected extreme values. In general, the performances of the majority of the CCQM-K106 participants are excellent, illustrating their measurement capability for Pb, As and Hg in a complex greasy matrix. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that

  15. CCQM-K103 key comparison melanine in milk powder

    NASA Astrophysics Data System (ADS)

    Li, Xiuqin; Zhang, Qinghe; Li, Hongmei; Li, Mengwan; Wong, Siu-kay; Lee, Foo-Wing; Kakoulides, Elias; Naujaus, Evaldas; Fernandes-Whaley, Maria; Prevoo-Franzsen, Des; Quinn, Laura; Pookrod, Preeyaporn; Konopelko, Leonid

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K103, was coordinated by the National Institute of Metrology (NIM) and Government Laboratory, Hong Kong, China (GLHK). The comparison was designed to demonstrate NMIs/DIs ability to analyze traces of melamine in milk and milk powder at concentration levels resulting from requirements for food safety. Seven NMIs or DIs participated in the comparison. Final reference value (KCRV) is 0.286 mg/kg, with standard uncertainty of the median as 0.011 mg/kg (3.8 %). The k-factor for the estimation of the expanded uncertainty was chosen as k = 2.57 ( t (0.05;5) ), thus the expanded uncertainty is 0.028 mg/kg (9.8%). The degrees of equivalence with melamine in milk powder KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for IDMS in determining mass fractions in the range from 0.1 to 5.0 mg/kg of analytes with low molar mass (range 50-300 Da) with high polarity (pKow > -2.0) in milk and milk products. Extension to other analytes and matrices should be applied with care since there is a close linkage to other relevant parameters as e.g. sample preparation procedures (liquid/liquid extraction, SPE clean-up) and analytical separation techniques (e.g., GC-MS, LC-MS/MS etc). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report on COOMET.QM-K76 (COOMET project no 484/RU/09): Key comparison of primary standard gas mixtures: SO2 in nitrogen (100 µmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Shor, N. B.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Kozia, V. G.; Shpilnyi, S. A.; Petryshyn, P. V.; Iakubov, S. E.; Kluchits, A. S.; Ananyin, V. N.; Mironchik, A. M.; Mokhnach, M. V.; Valkova, M.; Stovcik, V.

    2014-01-01

    Sulfur dioxide is one of the main contaminants present in the atmosphere due to burning of coal, oil and natural gas, smelting of base metals and production of sulfuric acid. Sulfur dioxide has been the subject of three previous CCQM key comparisons: CCQM-K1.d in 1997, CCQM-K26.b in 2005 and CCQM-K76 in 2010. VNIIM proposed a new COOMET project (No 484/RU/09) in this field, which was registered in the KCDB as key comparison COOMET.QM-K76. It was found that all results were consistent with the reference (gravimetric) values, with observed differences not exceeding ±0.60% and not exceeding either the appropriate assigned expanded uncertainties. VNIIM is the linking laboratory to CCQM-K76. SMU has improved the results obtained in CCQM-K76. The mixtures prepared for this exercise were found to be stable during about one year within the uncertainty of the measurements. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report of key comparison AFRIMETS.AUV.A-K5: primary pressure calibration of LS1P microphones according to IEC 61094-2, over the frequency range 2 Hz to 10 kHz.

    NASA Astrophysics Data System (ADS)

    Nel, R.; Avison, J.; Harris, P.; Blabla, M.; Hämäläinen, J.

    2017-01-01

    The degrees of equivalence of the AFRIMETS.AUV.A-K5 regional key comparison are reported here as the final report. The scope of the comparison covered the complex pressure sensitivities of two LS1P microphones over the frequency range 2 Hz to 10 kHz in accordance with IEC 61094-2: 2009. Four national metrology institutes from two different regional metrology organisations participated in the comparison. Two LS1P microphones were circulated simultaneously to all the participants in a circular configuration. One of the microphones sensitivity shifted and all results associated with this microphone were subsequently excluded from further analysis and linking. The AFRIMETS.AUV.A-K5 comparison results were linked to the CCAUV.A-K5 comparison results via dual participation in the CCAUV.A-K5 and AFRIMETS.AUV.A-K5 comparisons. The degrees of equivalence, linked to the CCAUV.A-K5 comparison, were calculated for all participants of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Report of the key comparison APMP.QM-K19. APMP comparison on pH measurement of borate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Obromsook, Krairerk; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Wong, Siu-Kay; Lam, Wai-Hing; Zakaria, Osman; Anuar Mohd. Amin, Khirul; Thanh, Ngo Huy; Máriássy, Michal; Vyskocil, Leos; Hankova, Zuzana; Fisicaro, Paola; Stoica, Daniela; Singh, Nahar; Soni, Daya; Ticona Canaza, Galia; Kutovoy, Viatcheslav; Barbieri Gonzaga, Fabiano; Dias, Júlio Cesar; Vospelova, Alena; Bakovets, Nickolay; Zhanasbayeva, Bibinur

    2015-01-01

    The APMP.QM-K19 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a borate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan (NMIJ) and the National Institute of Metrology (Thailand) (NIMT) at the APMP-TCQM meeting held 26-27 November 2012. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K19 and CCQM-K19.1. The comparison material was a borate buffer of pH around 9.2 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the second APMP key comparison on pH measurement and the fourth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006 and APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. The comparison and analysis of extracting video key frame

    NASA Astrophysics Data System (ADS)

    Ouyang, S. Z.; Zhong, L.; Luo, R. Q.

    2018-05-01

    Video key frame extraction is an important part of the large data processing. Based on the previous work in key frame extraction, we summarized four important key frame extraction algorithms, and these methods are largely developed by comparing the differences between each of two frames. If the difference exceeds a threshold value, take the corresponding frame as two different keyframes. After the research, the key frame extraction based on the amount of mutual trust is proposed, the introduction of information entropy, by selecting the appropriate threshold values into the initial class, and finally take a similar mean mutual information as a candidate key frame. On this paper, several algorithms is used to extract the key frame of tunnel traffic videos. Then, with the analysis to the experimental results and comparisons between the pros and cons of these algorithms, the basis of practical applications is well provided.

  20. KEY COMPARISON: Final report of APMP.T-K6 (original name APMP-IC-1-97): Comparison of humidity measurements using a dew point meter as a transfer standard

    NASA Astrophysics Data System (ADS)

    Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.

    2007-01-01

    This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. KEY COMPARISON: Report on the Regional Comparison COOMET.AUV.A-K3

    NASA Astrophysics Data System (ADS)

    Barrera-Figueroa, Salvador; Nielsen, Lars; Rasmussen, Knud

    2007-01-01

    COOMET.AUV.A-K3 is a Regional Comparison that supplements the Key Comparison CCAUV.A-K3 organized by the CCAUV. The participating NMIs are GUM (Poland), INM (Romania), VNIIFTRI (Russia) and DP-NDI 'Systema' (Ukraine). The role of Pilot laboratory was undertaken by DPLADFM (Denmark). The measurements took place between May 2005 and February 2006. The time schedule was organized in a single star configuration. Initially, two LS2aP microphones were circulated. However, a sudden change of sensitivity of one of them forced the inclusion of an additional microphone. Nevertheless, the analysis was performed on all microphones involved. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignation of degrees of equivalence and the link to the CCAUV.A-K3. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    NASA Astrophysics Data System (ADS)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    equivalence of participants in CCQM-K12. The range of participants' results in EURAMET.QM-K12 for both levels (2% and 3% respectively for materials A and B) was greater than the 1% achieved in CCQM-K12. However, it was concluded that this study was suitable to support CMCs for creatinine in serum for 1 µg/g to 100 µg/g with uncertainties at the 1% to 1.5% level. This was found to be fit for purpose and consistent with the majority of CMCs currently approved. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. KEY COMPARISON: CCQM-K27-Subsequent: Key Comparison (subsequent) for the determination of ethanol in aqueous matrix

    NASA Astrophysics Data System (ADS)

    Schantz, Michele M.; Duewer, David L.; Parris, Reenie M.; May, Willie E.; Archer, Marcellé; Mussell, Chris; Carter, David; Konopelko, Leonid A.; Kustikov, Yury A.; Krylov, Anatoli I.; Fatina, Olga V.

    2005-01-01

    ethanol in water were used in the subsequent study (nominal concentrations of 0.2 mg/g, 1 mg/g, 3 mg/g, and 60 mg/g). The three participants in the CCQM-K27-Subsequent Key Comparison demonstrated their ability to measure ethanol in aqueous matrix in the concentration range of 0.2 mg/g to 60 mg/g. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  4. Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 1 Ω resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Two BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The mean difference between the NMLI and the BIPM calibrations was found to be just within the expanded uncertainty (k = 2) of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Allisy-Roberts, P. J.; Burns, D. T.; Guerra, A. S.; Laitano, R. F.; Pimpinella, M.

    2010-01-01

    A comparison of the standards for absorbed dose to water of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI), and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation under the auspices of the key comparison BIPM.RI(I)-K4. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the ENEA and the BIPM standards for absorbed dose to water, is 0.9999 (0.0044). The present 2007 result replaces the earlier ENEA value in this key comparison. The degrees of equivalence between the ENEA and the other participants in this comparison have been calculated and the results are given in the form of a matrix for the ten national metrology institutes (NMIs) that have published results in this ongoing comparison for absorbed dose to water. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. SUPPLEMENTARY COMPARISON: Final report on Supplementary Comparison APMP.M.H-S1

    NASA Astrophysics Data System (ADS)

    Kongkavitool, Rugkanawan; Hattori, Koichiro; Sanh, Vo; Yen, Lim Gin

    2007-01-01

    , click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. KEY COMPARISON: BIPM comparison BIPM.RI(II)-K1.Cu-64 of the activity measurements of the radionuclide 64Cu

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Kossert, K.; Nähle, O. J.

    2009-01-01

    In 2009, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted a sample of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The value of the activity submitted was about 9.3 MBq. The result of this new comparison has been approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), comparison identifier BIPM.RI(II)-K1.Cu-64. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. KEY COMPARISON: Final report on CCQM-K63.a,b: Non-peptide hormones in serum: cortisol and progesterone

    NASA Astrophysics Data System (ADS)

    S-C Tai, Susan; Duewer, David L.

    2010-01-01

    /MS-based cortisol results is 100.4 ng/g with a relative standard deviation (%RSD) of 1.1%. The mean value for the seven ID/MS-based progesterone originally reported results is 2.83 with a %RSD of 1.8%. While a number of the reported results were not eligible to be used in establishing the KCRVs, the KCRVs as estimated from just the eligible results agree very well with these means. The excellent among-participant agreement indicates that ID/MS-based measurement procedures can provide precise and true results for steroid hormones at levels greater than about 1 ng/g. The progesterone result reported by a laboratory using a non-isotopically labelled internal standard was about 11% larger than the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 10 kΩ resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NMLI and the BIPM calibrations were found to be in agreement, with a mean difference smaller than the standard uncertainty of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Final report on international comparison CCQM-K83: Halocarbons in dry whole air

    NASA Astrophysics Data System (ADS)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Moon, Dongmin; Lee, Jinbok; Lim, Jeongsik; Seog Kim, Jin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a key comparison for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2 trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2 tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Power, Oliver

    2017-01-01

    This report presents the results of a bilateral comparison of capacitance at 100 pF between the NSAI-NML (Ireland) and the BIPM carried out in 2016. This comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b in which the BIPM is the pilot laboratory. Two 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring rms voltage of 15 V. The results from the NSAI-NML and the BIPM were found to be in relatively good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.85 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Final report of the key comparison CCQM-K98: Pb isotope amount ratios in bronze

    NASA Astrophysics Data System (ADS)

    Vogl, Jochen; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Goenaga-Infante, Heidi; Malinowskiy, Dmitriy; Ren, Tongxiang; Wang, Jun; Vocke, Robert D., Jr.; Murphy, Karen; Nonose, Naoko; Rienitz, Olaf; Noordmann, Janine; Näykki, Teemu; Sara-Aho, Timo; Ari, Betül; Cankur, Oktay

    2014-01-01

    ) were selected such that they correspond with those commonly reported in Pb isotopic studies and fully describe the isotopic composition of Pb in the sample. Additionally, the isotope amount ratio n(208Pb)/n(206Pb) was added, as this isotope ratio is typically measured when performing Pb quantitation by IDMS involving a 206Pb spike. Each participant was free to use any method they deemed suitable for measuring the individual isotope ratios. However, the majority of the results were obtained by using muIti-collector ICPMS or TIMS. The key requirements for all analytical procedures were a traceability statement for all results and the establishment of an uncertainty budget meeting a target uncertainty for all ratios of 0.2 %, relative (k=1). Additionally, the use of a Pb-matrix separation procedure was encouraged. The obtained overall result was excellent, demonstrating that the individual results reported by the NMIs/DIs were comparable and compatible for the determination of Pb isotope ratios. MC-ICPMS and MC-TIMS data were consistent with each other and agree to within 0.05 %. The corresponding uncertainties can be considered as realistic uncertainties and mainly range from 0.02 % to 0.08 % (k=1). As stated above isotope ratios are being increasingly used in different fields. Despite the availability and ease of use of new mass spectrometers, the metrology of unbiased isotope ratio measurements remains very challenging. Therefore, further comparisons are urgently needed, and should be designed to also engage scientists outside the NMI/DI community. Possible follow-up studies should focus on isotope ratio and delta measurements important for environmental and technical applications (e.g. B), food traceability and forensics (e.g. H, C, N, O, S and 87Sr/86Sr) or climate change issues (e.g. Li, B, Mg, Ca, Si). Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.

  13. Final Report on the Key Comparison CCM.P-K4.2012 in Absolute Pressure from 1 Pa to 10 kPa

    PubMed Central

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. PMID:28216793

  14. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Burns, D. T.; Berlyand, V.; Berlyand, A.

    2010-01-01

    A new comparison of the standards for absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation in 2009. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9976 for the calibration coefficients of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. This result is consistent with the earlier 2001 comparison result of 0.9967 (43). The updated degrees of equivalence for the VNIIFTRI are compared with those of the other national metrology institutes as presented in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. CCQM key comparison CCQM-K75: Determination of toxic metals in algae

    NASA Astrophysics Data System (ADS)

    Shakhashiro, A.; Toervenyi, A.; Gaudino, S.; Rosamilia, S.; Belli, M.; Turk, G. C.

    2011-01-01

    in algae matrix. In addition, the NMIs demonstrated a wide range of 'core-capabilities' applicable to other measurement applications. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Final report on EURAMET.M.P-K4.2010: Key and supplementary comparison of national pressure standards in the range 1 Pa to 15 kPa of absolute and gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajíček, Zdeněk; Bergoglio, Mercede; Jousten, Karl; Otal, Pierre; Sabuga, Wladimir; Saxholm, Sari; Pražák, Dominik; Vičar, Martin

    2014-01-01

    This report describes a EURAMET comparison of five European National Metrology Institutes in low gauge and absolute pressure in gas (nitrogen), denoted as EURAMET.M.P-K4.2010. Its main intention is to state equivalence of the pressure standards, in particular those based on the technology of force-balanced piston gauges such as e.g. FRS by Furness Controls, UK and FPG8601 by DHI-Fluke, USA. It covers the range from 1 Pa to 15 kPa, both gauge and absolute. The comparison in absolute mode serves as a EURAMET Key Comparison which can be linked to CCM.P-K4 and CCM.P-K2 via PTB. The comparison in gauge mode is a supplementary comparison. The comparison was carried out from September 2008 till October 2012. The participating laboratories were the following: CMI, INRIM, LNE, MIKES, PTB-Berlin (absolute pressure 1 kPa and below) and PTB-Braunschweig (absolute pressure 1 kPa and above and gauge pressure). CMI was the pilot laboratory and provided a transfer standard for the comparison. This transfer standard was also the laboratory standard of CMI at the same time, which resulted in a unique and logistically difficult star comparison. Both in gauge and absolute pressures all the participating institutes successfully proved their equivalence with respect to the reference value and all also proved mutual bilateral equivalences in all the points. All the participating laboratories are also equivalent with the reference values of CCM.P-K4 and CCM.P-K2 in the relevant points. The comparison also proved the ability of FPG8601 to serve as a transfer standard. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report on bilateral comparison SIM.EM-S9.b: Comparison of resistance standards at 1 Ω and 10 kΩ between INIMET (Cuba) and INTI (Argentina), March to October 2012

    NASA Astrophysics Data System (ADS)

    Tonina, A.; Currás, M.; Navarro, M.

    2014-01-01

    The CIPM MRA states that its technical basis is a set of results obtained in a course of time through key comparisons carried out by the Consultative Committees of the CIPM, the BIPM and the Regional Metrology Organizations (RMOs). As part of this process, INTI (Argentina) has participated in several key and supplementary comparisons. By means of procedures for linking key comparison data, a bilateral comparison would help to provide assurance of equality in measurements between the participating laboratories. With this end, the comparison SIM.EM-S9.b of 1 ohm and 10 kiloohm standard resistors of INIMET (Cuba) and INTI was carried out from March to October 2012. The obtained results were very good. They show that the resistance standards maintained by INTI and INIMET were equivalent, within their combined uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Results and evaluation of key comparison CCM.P-K12.1 for very low helium flow rates (leak rates)

    NASA Astrophysics Data System (ADS)

    Šetina, Janez; Vičar, Martin; Pražák, Dominik

    2015-01-01

    The Czech Metrology Institute (CMI) took part and failed to prove equivalence in the Key Comparison CCM.P-K12 of helium leak artefacts (leak rates) into vacuum. After identifying and eliminating the cause of the failure, the Institute of Metals and Technology (IMT) of Slovenia, a successful participant in CCM.P-K12, volunteered to serve as pilot and link in a following bilateral comparison of IMT and CMI that obtained designation CCM.P-K12.1 in June 2012. It was decided to perform the comparison with a glass permeation helium leak artefact at nominally 3.10-11 mol/s (7.4.10-7 mbar.L.s-1) at 23 °C. Both the laboratory standards took part in CCM.P-K12 and were considered as primary. The comparison measurements were performed in October 2012. CMI proved equivalence both with IMT and with the reference value of the key comparison CCM.P-K12. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. KEY COMPARISON Bilateral comparison of 1.018 V and 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2010 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2010-01-01

    As a part of the ongoing BIPM key comparisons BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and of the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2010. Two BIPM Zener diode-based travelling standards were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage is maintained at the 10 V level by means of a group of characterized Zener diode-based electronic voltage standards. The output EMF of each travelling standard, at the 10 V output terminals, was measured by direct comparison with the group standard. Measurements of the output EMF of the travelling standards at the 1.018 V output terminals were made using a potentiometer, standardized against the local 10 V reference standard. At the BIPM, the travelling standards were calibrated at both voltages before and after the measurements at NSAI-NML, using the BIPM Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. KEY COMPARISON Comparison of the standards of air kerma of the ENEA-INMRI and the BIPM for 137Cs gamma rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Toni, M.; Bovi, M.

    2010-01-01

    A comparison of the standards of air kerma of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI) and of the Bureau International des Poids et Mesures (BIPM) was carried out in 137Cs radiation in 1998. The comparison result, updated for changes in the standards in 2003 and 2009, is 0.9927 (0.0067) and demonstrates that the ENEA-INMRI and BIPM standards are in agreement within the uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. KEY COMPARISON: CCQM-K25: Determination of PCB congeners in sediment

    NASA Astrophysics Data System (ADS)

    Schantz, Michele; Wise, Stephen

    2004-01-01

    congener as internal standard showed no systematic bias from the results of other laboratories. The five PCB congeners measured in CCQM-K25 were selected to be representative of the approximately 150 congeners found in environmental samples and to provide the typical analytical measurement challenges encountered in the measurement of individual congeners such as volatility losses during sample preparation and coelution during chromatographic separation. The abilities demonstrated by the laboratories that provided comparable measurements for all five congeners in this Key Comparison should be indicative of their ability to provide reference measurements for the typical suite of PCB congeners found in moderately contaminated sediments (individual congener amount of substance concentrations >5 ng/g dry basis). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  2. KEY COMPARISON: CCEM.RF-K9: International comparison of thermal noise standards between 12.4 GHz and 18 GHz (GT-RF/99-1)

    NASA Astrophysics Data System (ADS)

    Allal, Djamel; Achkar, Joseph

    2006-01-01

    An international comparison of thermal noise-power measurements has been carried out among five national metrology institutes between 12.4 GHz and 18 GHz. Four transfer standards were measured. The following national institutes participated: BNM-LCIE (France), NPL (United Kingdom), PTB (Germany), NIST (United States of America) and VNIIFTRI (Russia). The Bureau National de Métrologie-Laboratoire Central des Industries Electriques (France) acted as the pilot laboratory for the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Final report on the Seventh International Comparison of Absolute Gravimeters (ICAG 2005)

    USGS Publications Warehouse

    Jiang, Z.; Francis, O.; Vitushkin, L.; Palinkas, V.; Germak, A.; Becker, M.; D'Agostino, G.; Amalvict, M.; Bayer, R.; Bilker-Koivula, M.; Desogus, S.; Faller, J.; Falk, R.; Hinderer, J.; Gagnon, C.; Jakob, T.; Kalish, E.; Kostelecky, J.; Lee, C.; Liard, J.; Lokshyn, Y.; Luck, B.; Makinen, J.; Mizushima, S.; Le, Moigne N.; Origlia, C.; Pujol, E.R.; Richard, P.; Robertsson, L.; Ruess, D.; Schmerge, D.; Stus, Y.; Svitlov, S.; Thies, S.; Ullrich, C.; Van Camp, M.; Vitushkin, A.; Ji, W.; Wilmes, H.

    2011-01-01

    The Bureau International des Poids et Mesures (BIPM), S??vres, France, hosted the 7th International Comparison of Absolute Gravimeters (ICAG) and the associated Relative Gravity Campaign (RGC) from August to September 2005. ICAG 2005 was prepared and performed as a metrological pilot study, which aimed: To determine the gravity comparison reference values; To determine the offsets of the absolute gravimeters; and As a pilot study to accumulate experience for the CIPM Key Comparisons. This document presents a complete and extensive review of the technical protocol and data processing procedures. The 1st ICAG-RGC comparison was held at the BIPM in 1980-1981 and since then meetings have been organized every 4 years. In this paper, we present an overview of how the meeting was organized, the conditions of BIPM gravimetric sites, technical specifications, data processing strategy and an analysis of the final results. This 7th ICAG final report supersedes all previously published reports. Readings were obtained from participating instruments, 19 absolute gravimeters and 15 relative gravimeters. Precise levelling measurements were carried out and all measurements were performed on the BIPM micro-gravity network which was specifically designed for the comparison. ?? 2011 BIPM & IOP Publishing Ltd.

  4. Final report on the key comparison, CCM.M.P-K15.1 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Hongyan, Yu

    2017-01-01

    At the CCM WG-LP meeting in Berlin in April 2011 the National Institute of Metrology of the people's republic of China asked for an opportunity to be linked to the CCM.M.P-K15 comparison which just ended. METAS, which had been active as pilot for the CCM.M.P-K15, agreed to make a link with NIM. The NIM introduced a new static expansion system in his laboratory. Two spinning rotor gauges and a control electronic are used as transfer standard. The circulation of the transfer standard was made in spring 2012. The drift of the accommodation coefficient of the two SRG was measured by the pilot before and after the comparison. The stability of the transfer standards was excellent and the equivalence between METAS and NIM has been demonstrated. A link to the CCM.M.P­K15 has been established using the results from METAS. It has been possible to achieve a link with a small uncertainty due to the strong correlation of the measurements of METAS in the two comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Report on key comparison COOMET.AUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Dobrowolska, D.; Kosterov, A.

    2016-01-01

    This is the final report for regional key comparison COOMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Two laboratories—Central Office of Measures (GUM)—the national metrology institute for Poland and the State Enterprise Scientific-Research Institute for Metrology of Measurement and Control Systems (DP NDI Systema)— the designated institute for acoustics in Ukraine took part in this comparison with the GUM as a pilot. One travelling type LS1P microphone was circulated to the participants and results in the form of regular calibration certificates were collected. The results of the DP NDI Systema obtained in this comparison were linked to the CCAUV.A-K5 key comparison through the joint participation of the GUM. The degrees of equivalence were computed for DP NDI Systema with respect to the CCAUV.A-K5 key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Key comparison BIPM.RI(I)-K9 of the absorbed dose to water standards of the PTB, Germany and the BIPM in medium-energy x-rays

    NASA Astrophysics Data System (ADS)

    Burns, D. T.; Kessler, C.; Büermann, L.; Ketelhut, S.

    2018-01-01

    A key comparison has been made between the absorbed dose to water standards of the PTB, Germany and the BIPM in the medium-energy x-ray range. The results show the standards to be in general agreement at the level of the standard uncertainty of the comparison of 9 to 11 parts in 103. The results are combined with those of a EURAMET comparison and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.66 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A—B—A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 2.5 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report on COOMET.AUV.A-S1: Technical report on supplementary comparison 'Comparison of national standards of the sound pressure unit in air through calibration of working reference microphones'

    NASA Astrophysics Data System (ADS)

    Pozdeeva, Valentina; Chalyy, Vladimir

    2014-01-01

    The supplementary comparison COOMET.AUV.A-S1 for secondary calibration methods using WS1 and WS2 measurement microphones was carried out from 2009 to 2010. The results were submitted to and approved by CCAUV in April 2014. Four National Metrology Institutes took part in this comparison and are as follows: BelGIM (Belarus), VNIIFTRI (Russia), SMU (Slovakia) and DP NDI 'Sistema' (Ukraine). Three of the above NMIs (VNIIFTRI, SMU and DP NDI 'Sistema') had earlier participated in COOMET key comparisons and one NMI (VNIIFTRI) had also participated in CCAUV key comparisons. The Comparison Reference Values were calculated as the weighted mean values from results obtained by three institutes. The comparison results show agreement for all participants in the frequency range from 20 Hz to 12.5 kHz for WS1 microphones, and in the frequency range from 20 Hz to 16 kHz for WS2 microphones. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the SMU, Slovakia and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    A key comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0042 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Final report of the supplementary comparison EURAMET.EM-S31 comparison of capacitance and capacitance ratio

    NASA Astrophysics Data System (ADS)

    Schurr, J.; Fletcher, N.; Gournay, P.; Thévenot, O.; Overney, F.; Johnson, L.; Xie, R.; Dierikx, E.

    2017-01-01

    Within the framework of the supplementary comparison EURAMET.EM-S31, 'Comparison of capacitance and capacitance ratio', five participants (the BIPM, METAS, LNE, PTB, and VSL) inter-compared their capacitance realisations traced to the quantum Hall resistance measured at either ac or dc. The measurands were the capacitance values of three 10 pF standards and one 100 pF standard, and optionally their voltage and frequency dependences. Because the results were not fully satisfying, the circulation was repeated, augmented by a link to the NMIA calculable capacitor. Also two ac-dc resistors were circulated and their frequency dependences were measured in terms of the ac-dc resistance standards involved in the particular capacitance realisations, to allow inter-comparison of these resistance standards. At the end and in any case, a good agreement is achieved within the expanded uncertainties at coverage factor k = 2. Furthermore, the comparison led to new insight regarding the stability and travelling behaviour of the capacitance standards and, by virtue of the link to the NMIA calculable capacitor, to a determination of the von Klitzing constant in agreement with the 2014 CODATA value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report on EURAMET.L-S21: `Supplementary comparison of parallel thread gauges'

    NASA Astrophysics Data System (ADS)

    Mudronja, Vedran; Šimunovic, Vedran; Acko, Bojan; Matus, Michael; Bánréti, Edit; István, Dicso; Thalmann, Rudolf; Lassila, Antti; Lillepea, Lauri; Bartolo Picotto, Gian; Bellotti, Roberto; Pometto, Marco; Ganioglu, Okhan; Meral, Ilker; Salgado, José Antonio; Georges, Vailleau

    2015-01-01

    The results of the comparison of parallel thread gauges between ten European countries are presented. Three thread plugs and three thread rings were calibrated in one loop. Croatian National Laboratory for Length (HMI/FSB-LPMD) acted as the coordinator and pilot laboratory of the comparison. Thread angle, thread pitch, simple pitch diameter and pitch diameter were measured. Pitch diameters were calibrated within 1a, 2a, 1b and 2b calibration categories in accordance with the EURAMET cg-10 calibration guide. A good agreement between the measurement results and differences due to different calibration categories are analysed in this paper. This comparison was a first EURAMET comparison of parallel thread gauges based on the EURAMET ctg-10 calibration guide, and has made a step towards the harmonization of future comparisons with the registration of CMC values for thread gauges. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NIS (Egypt) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Helmy, M.; Raouf, A.; Hamed, Heba A. M.; Eliwa Gad, A.

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NIS (Egypt) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NIS, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NIS and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of about 0.72 × 10-6 at 10 pF and about 0.65 × 10-6 at 100 pF. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the SMD (Belgium) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, Benjamin; Fletcher, Nick; Vlad, Dana

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the SMD (Belgium) and the BIPM carried out in 2017. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the SMD, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13.b (for 10 kΩ). The results from the SMD and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.080 × 10-6 for 1 Ω and 0.068 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIMT (Thailand) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Khumthukthit, N.; Jassadajin, C.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NIMT (Thailand) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NIMT and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.20 × 10-6 for 1 Ω and 0.74 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report of the SIM.QM-S8 supplementary comparison, trace metals in drinking water

    NASA Astrophysics Data System (ADS)

    Yang, Lu; Nadeau, Kenny; Gedara Pihillagawa, Indu; Meija, Juris; Mester, Zoltan; Napoli, Romina; Pérez Zambra, Ramiro; Ferreira, Elizabeth; Alejandro Ahumada Forigua, Diego; Abella Gamba, Johanna Paola

    2018-01-01

    After completing a supplementary comparison SIM.QM-S7, the National Metrology Institute of Colombia (NMIC) requested to National Research Council of Canada (NRC) a subsequent bilateral comparison, because INMC considered that its results in SIM.QM-S7 unrepresentative of its standards. In this context, NRC agreed to coordinate this bilateral comparison with the aim of demonstrating the measurement capabilities of trace elements in fresh water. Participants included NMIC and LATU. No measurement method was prescribed by the coordinating laboratory. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S8 Supplementary Comparison provides NMIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. CCQM-K104 key comparison (avermectin B1a) on the characterization of organic substances for chemical purity

    NASA Astrophysics Data System (ADS)

    Dai, Xinhua; Zhang, Wei; Li, Hongmei; Huang, Ting; Li, Mengwan; Quan, Can; Zhang, Qinghe; Davies, Stephen R.; Warren, John; Lo, Man-fung; Kakoulides, Elias; Ceyhan Gören, Ahmet; Marbumrung, Sornkrit; Pfeifer, Dietmar; Ün, İlker; Gündüz, Simay; Yilmaz, Hasibe; Kankaew, Pornhatai; Sudsiri, Nittaya; Shearman, Kittiya; Pookrod, Preeyaporn; Polzer, Joachim; Radeck, Wolfgang

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K104, was coordinated by the National Institute of Metrology (NIM). The comparison was designed to demonstrate a laboratory's performance in determining the mass fraction of the main component in a complex high purity organic material. Nine NMIs or DIs participated in the comparison. Eight participants reported their results. An additional impurity was resolved from the avermectin B1a peak and was tentatively identified as an unknown impurity by NMIA (National Measurement Institute (Australia)). It was subsequently identified by NIM as a diastereoisomer of avermectin B1a at the C-26 position. Final reference value (KCRV) = 924.63 mg/g, with uncertainty (k=1) = 3.89 mg/g, and expanded uncertainty = 8.97 mg/g. The degrees of equivalence with the avermectin B1a KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of high structural complexity (relative molecular mass range of 500 Da -1000 Da and low polarity (-log KOW <= -2). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Key comparison SIM.EM.RF-K5b.CL: scattering coefficients by broad-band methods, 2 GHz-18 GHz — type N connector

    NASA Astrophysics Data System (ADS)

    Silva, H.; Monasterios, G.

    2016-01-01

    The first key comparison in microwave frequencies within the SIM (Sistema Interamericano de Metrología) region has been carried out. The measurands were the S-parameters of 50 ohm coaxial devices with Type-N connectors and were measured at 2 GHz, 9 GHz and 18 GHz. SIM.EM.RF-K5b.CL was the identification assigned and it was based on a parent CCEM key comparison named CCEM.RF-K5b.CL. For this reason, the measurements standards and their nominal values were selected accordingly, i.e. two one-port devices (a matched and a mismatched load) to cover low and high reflection coefficients and two attenuators (3dB and 20 dB) to cover low and high transmission coefficients. This key comparison has met the need for ensuring traceability in high-frequency measurements across America by linking SIM's results to CCEM. Six NMIs have participated in this comparison which was piloted by the Instituto Nacional de Tecnología Industrial (Argentina). A linking method of multivariate values was proposed and implemented in order to allow the linking of 2-dimensional results. KEY WORDS FOR SEARCH Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NMISA (South Africa) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Khoza, Michael

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NMISA (South Africa) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NMISA, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NMISA and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of maximum value 0.33 × 10-6 at 10 pF and 0.24 × 10-6 at 100 pF (and 1000 Hz in both cases). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Bilateral key comparison CCM.P-K3.1 for absolute pressure measurements from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Fedchak, J. A.; Bock, Th; Jousten, K.

    2014-01-01

    This report describes the bilateral key comparison CCM.P-K3.1 between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt (PTB) for absolute pressure in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. This comparison was a follow-up to the comparison CCM.P-K3. Two ionization gauges and two spinning rotor gauges (SRGs) were used as the transfer standards for the comparison. The SRGs were used to compare the standards at a pressure of 9 × 10-4 Pa and to normalize the ionization gauge readings. The two ionization gauges were used to compare the standards in the pressure range of from 3 × 10-6 Pa to 3 × 10-4 Pa. Both laboratories used dynamic expansion chambers as standards in the comparison. The two labs showed excellent agreement with each other and with the CCM.P-K3 key comparison reference value (KCRV) over the entire range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Report of the key-comparison of spectral diffuse reflectance (EURAMET.PR-K5) (Ref. 619)

    NASA Astrophysics Data System (ADS)

    Andor, György; Gál, Péter

    2018-01-01

    This report details the final results of the EURAMET comparison on regular spectral transmittance carried out between 2006 and 2016. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 780 nm at 20 nm increment. We used a star type comparison: first the participants sent their samples to the pilot, than the pilot measured all the samples of the participants and sent them back. The participants measured the samples and sent them to the pilot for control measurement. Six standards were used as reference standards in order to maintain the scale during the comparison. These were three samples of BCR-406 opal glasses (BCR 30506; BCR 30303; BCR 30704), an MC20 Russian opal glass (MC 4777) and two samples made of pressed halon (polytetrafluoroethylene) powder (halon 2007A; halon 2007C). These six samples were designated as the Comparison reference standards. The diffuse reflectance was initially measured on the OMH (BFKH) absolute reflectometer. The link to the CCPR-K5 results was BFKH, and the check on BFKH was the PTB results who also participated in the CCPR-K5 comparison. The participants were GUM, INM, LNE, METAS, BFKH, PTB, SP. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the CMI (Czech Republic) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Kučera, J.; Chrobok, P.; Vo&jacute; čko&vacute; , L.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the CMI (Czech Republic) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the CMI and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.046 × 10-6 for 1 Ω and 0.034 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Power, O.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.16 × 10-6 for 1 Ω and 0.42 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. KEY COMPARISON: CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    NASA Astrophysics Data System (ADS)

    Hill, K. D.; Steele, A. G.; Dedikov, Y. A.; Shkraba, V. T.

    2005-01-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 Ω capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L&N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions

  8. APMP key comparison for the measurement of air kerma for 60Co (APMP.RI(I)-K1.1)

    NASA Astrophysics Data System (ADS)

    Webb, D. V.; Lee, J.-H.; Budiantari, C. T.; Laban, J.; Saito, N.; Srimanoroth, S.; Khaled, N. E.

    2016-01-01

    include three new entries since neither the PTKMR-BATAN nor the NCRS have yet been declared designated institutes and consequently their results cannot be entered. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the BIM (Bulgaria) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Tenev, A.; Hadzhistoykova, R.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the BIM (Bulgaria) and the BIPM carried out in 2013. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.30 × 10-6 at 10 kΩ and in reasonable agreement for 1 Ω with a relative difference of -0.18 × 10-6 with a relative expanded uncertainty of 0.17 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Final report of international comparison APMP.QM-S2.2015 of oxygen in nitrogen at 0.2 mol/mol

    NASA Astrophysics Data System (ADS)

    Aoki, Nobuyuki; Shimosaka, Takuya; Lin, Tsai-Yin; Liu, Hsin-Wang; Huang, Chiung-Kun; Wongjuk, Arnuttachai; Rattanasombat, Soponrat; Sinweeruthai, Ratirat; Uehara, Shinji; Aleksandrov, Vladimir

    2017-01-01

    This document describes the results of the supplementary comparison for oxygen in nitrogen gas mixture. The nominal amount-of-substance fraction of oxygen is 0.20 mol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Comparison-Bot: an Automated Preliminary-Final Report Comparison System.

    PubMed

    Kalaria, Amit D; Filice, Ross W

    2016-06-01

    Regular comparison of preliminary to final reports is a critical part of radiology resident and fellow education as prior research has documented substantial preliminary to final discrepancies. Unfortunately, there are many barriers to this comparison: high study volume; overnight rotations without an attending; the ability to finalize reports remotely; the subtle nature of many changes; and lack of easy access to the preliminary report after finalization. We developed a system that automatically compiles and emails a weekly summary of report differences for all residents and fellows. Trainees can also create a custom report using a date range of their choice and can view this data on a resident dashboard. Differences between preliminary and final reports are clearly highlighted with links to the associated study in Picture Archiving and Communication Systems (PACS) for efficient review and learning. Reports with more changes, particularly changes made in the impression, are highlighted to focus attention on those exams with substantive edits. Our system provides an easy way for trainees to review changes to preliminary reports with immediate access to the associated images, thereby improving their educational experience. Departmental surveys showed that our report difference summary is easy to understand and improves the educational experience of our trainees. Additionally, interesting descriptive statistics help us understand how reports are changed by trainee level, by attending, and by exam type. Finally, this system can be easily ported to other departments who have access to their Health Level 7 (HL7) data.

  12. Key comparison BIPM.RI(I)-K5 of the air kerma standards of the ININ, Mexico and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D. T.; Alvarez Romero, J. T.; De la Cruz Hernández, D.; Cabrera Vertti, M. R.; Tovar-Muñoz, V. M.

    2015-01-01

    A direct comparison of the standards for air kerma of the Instituto Nacional de Investigaciones Nucleares (ININ), Mexico, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in February 2015. The comparison result, evaluated as a ratio of the ININ and the BIPM standards for air kerma, is 1.0048 with a combined standard uncertainty of 2.0 × 10-3. The results are analysed and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2011-01-01

    As a part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2011. Two BIPM Zener diode-based travelling standards (Fluke 732B) were transported by freight to NSAI-NML. At NSAI-NML, the 10 V output EMF of each travelling standard was measured by direct comparison with a group of characterized Zener diode-based electronic voltage standards. At the BIPM, the travelling standards were calibrated before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Key comparison BIPM.RI(I)-K5 of the air-kerma standards of the SMU, Slovakia and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    The first direct comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0051 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the MKEH, Hungary and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Machula, G.

    2018-01-01

    A comparison of the standards for air kerma of the Hungarian Trade Licensing Office (MKEH), Hungary and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in March 2016. The comparison result, evaluated as a ratio of the MKEH and the BIPM standards for air kerma, is 1.0047 with a combined standard uncertainty of 1.9 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2.6 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final Report: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo

    2015-01-01

    The EURAMET.M.FF-K6 comparison was organized for the purpose of determination of the degree of equivalence of the primary (national) standards for low-pressure gas flow measurement over the range (2 to 100) m3/h and was performed simultaneously with CCM.FF-K6.2011 with the same transfer standard. A rotary gas meter G65 was used as a transfer standard. The measurements were provided by prescribed reference conditions. Fifteen laboratories from EURAMET participated in this key comparison - SMU, Slovakia; PTB, Germany; CEM, Spain; LNE-LADG, France; VSL, Netherlands; CMI, Czech Republic; BEV, Austria; MKEH, Hungary; GUM Poland; SP, Sweden; METAS, Switzerland; DMDM, Serbia; TUBITAK-UME, Turkey; EIM, Greece; IMBiH, Bosnia-Herzegovina. The EURAMET.M.FF-K6 is linked to the CCM.FF-K6.2011 by correcting the results of three linking laboratories (Slovakia SMU, Germany PTB and France LNE LADG). This correction provides an estimate of what would have been the result from the EURAMET.M-FF-K6 participants, if they had actually participated in CCM.FF-K6.2011. According to the evaluation 93.7 % of the results were consistent with KCRV, 3.4 % of the results were in the warning level and 2.9 % of the results were inconsistent. The results of this comparison can be used for review of the CMC tables. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report on the regional supplementary comparison APMP.AUV.A-S1

    NASA Astrophysics Data System (ADS)

    Plangsangmas, Virat; Leeudomwong, Surat; Scott, Andrew; Zhong, Bo; Huang, Yuchung

    2014-01-01

    A regional supplementary comparison APMP.AUV.A-S1 has been carried out for the measurement of sound pressure level, frequency and total distortion of a multi-frequency sound calibrator. The role of the Pilot laboratory was undertaken by the National Institute of Metrology (Thailand) (NIMT). The multi-frequency sound calibrator was circulated through thirteen National Metrology Institutes (NMIs). Two NMIs were added to the original time schedule after starting the circulation. The measurements took place between September 2008 and July 2010. This report includes the measurement results from all the participants. Supplementary Comparison Reference Values (SCRVs) have been determined from the results. Deviations from the SCRVs are mostly within declared expanded uncertainties. It has been found that a term for the inherent instability in this type of device needs to be included in any uncertainty budget, and a recommended minimum value of this has been given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on the torque key komparison CCM.T-K1.2 measurand torque: 0 N.m, 500 N.m, 1000 N.m

    NASA Astrophysics Data System (ADS)

    Röske, Dirk

    2015-01-01

    The purpose of the CIPM subsequent bilateral comparison CCM.T-K1.2 was to link another participant, namely the National Institute of Metrology (Thailand), in short NIMT, to the CCM.T-K1 torque key comparison. The measuring capabilities up to 1000 N.m of dead-weight torque standard machines with supported lever were investigated. The pilot laboratory was the same in both comparisons—it was the Physikalisch-Technische Bundesanstalt (PTB, Braunschweig, Germany). The same two very stable torque transducers with well-known properties were used as travelling standards. The measurements at the participating laboratory were carried out between November 2007 and February 2008. According to the technical protocol, torque steps of 500 N.m and 1000 N.m had to be measured both in clockwise and anticlockwise directions. Corrections had to be applied to the results reported by the participants taking into account the use of different amplifiers, the creep (due to different loading times of the machines) and the environmental conditions in the laboratories (temperature and relative humidity of the ambient air). The results of the pilot laboratory in this bilateral comparison are in very good agreement with the same results obtained in the CCM.T-K1 comparison. For each of the transducers, the two torque steps and both senses of direction of the torque vector, the key comparison reference value of the CCM.T-K1 was taken, and the results of participant NIMT were calculated with respect to these values. The agreement between the results is very good. The smallest expanded (k = 2) relative uncertainty of the machine stated by the participant is 1 × 10-4. The results of the comparison support this uncertainty statement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according

  19. Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.; Rujirat, N.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device. Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 2.6 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. On-site comparison of Quantum Hall Effect resistance standards of METAS and the BIPM: Ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Mortara, Alessandro; Jeanneret, Blaise

    2018-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Federal Institute of Metrology METAS (Switzerland) and of the Bureau International des Poids et Mesures (BIPM) was made in December 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 5 parts in 1010 with a relative combined standard uncertainty uc = 23 × 10‑10. Scaling from 100 Ω to 10 kΩ has also been addressed through the measurement of a 10000 Ω/100 Ω ratio. The measurements carried out agreed to 2 parts in 1010 with a relative combined standard uncertainty uc = 19 × 10‑10. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Report of the key comparison CCQM-K108 determination of arsenic species, total arsenic and cadmium in brown rice flour

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shinichi; Kotzeva, Boriana; Kakoulides, Elias; Sxoina, Vasiliki; Fung, W. H.; Choi, Y. Y.; Yau, H. P.; Tsoi, Y. T.; Lee, C. L.; Kong, M. F.; Shin, Richard; Juan, Wang; Sin Yee, Ng; Uribe, Christian; Marques Rodrigues, Janaína; Caciano de Sena, Rodrigo; Silva Dutra, Emily; Bergamaschi, Luigi; Giordani, Laura; D'Agostino, Giancarlo; Valiente, Liliana; Horvat, Milena; Jacimovic, Radojko; Oduor Okumu, Tom; Kang'Iri, Jacqueline; Owiti Orwa, Tabitha; Chao, Wei; Jingbo, Chao; Taebunpakul, Sutthinun; Yafa, Charun; Kaewkhomdee, Nattikarn; Chailap, Benjamat; Pharat, Yanee; Phukphattanachai, Pranee; Turk, Gregory C.; Long, Stephen; Murphy, K. E.; Davis, Clay; Ellisor, Michael; Merrick, Jeffrey; White, Ian; Saxby, David; Linsky, S. M.; Barzev, A.; Botha, A.

    2015-01-01

    The CCQM-K108 key comparison was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes (NMIs) or designated institutes (DIs) to measure the mass fractions of arsenic species, total arsenic and cadmium in brown rice flour. The National Metrology Institute of Japan (NMIJ) acted as the coordinating laboratory. The participants used different measurement methods, though most of them used inductively coupled plasma mass spectrometry (ICP-MS) or isotope-dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) for Cd and ICP-MS for total arsenic. Regarding arsenic speciation, all participants used ICP-MS coupled with liquid chromatography (LC). Accounting for relative expanded uncertainty, comparability of measurement results for each of total arsenic and cadmium was successfully demonstrated by the participating NMIs or DIs for the measurement of the measurand at the level of less than 0.5 mg/kg. Regarding arsenic species (inorganic arsenic and dimethylarsinic acid (DMAA)), there was, however, a measurement problem still to be solved and that part of CCQM-K108 will be repeated. It is expected that arsenic, cadmium and other metals at mass fractions greater than approximately 0.1 mg/kg in rice flour can be determined by each participant using the same technique(s) employed for this key comparison to achieve similar uncertainties mentioned in the present report. Furthermore, the results of this key comparison can be utilised along with the IAWG core capability approach. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Final report on EURAMET.QM-S10/1274: supplementary comparison of preparative capabilities for automotive gas mixtures

    NASA Astrophysics Data System (ADS)

    Val'ková, M.; Ďurišová, Z.; Szilágyi, Z. N.; Büki, T.; Fükű, J.

    2016-01-01

    This bilateral supplementary preparative comparison involves standard gas mixtures of automotive gas containing carbon monoxide, carbon dioxide and propane in nitrogen. Two laboratories (SMU, Slovakia and MKEH, Hungary) participated in this supplementary comparison. SMU was the coordinating laboratory, responsible for collecting and reporting measurement results. The participants have established facilities for automotive gas gravimetric preparation and analysis. The agreement of the results in this supplementary comparison is good. All the results with their reported uncertainties are in agreement with the reference values for the participants. SMU participated and obtained good results in the previous preparative comparison organised within EURAMET in this field. Both laboratories have existing claims for their Calibration and Measurement Capabilities (CMCs) for automotive gas mixtures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report of EURAMET 1197: Supplementary bilateral comparison of hydraulic gauge pressure standards up to 50 MPa

    NASA Astrophysics Data System (ADS)

    Durgut, Yasin; Petrovski, Nenad; Kacarski, Vanco

    2012-01-01

    Interlaboratory comparisons are important for the laboratories to assess their own measurement capability. It is equally important for the accreditation bodies and assessors during the audit process of a laboratory to judge whether the laboratory is doing well. As per accreditation rules, it is mandatory for the testing and calibration laboratories to participate in such comparisons from time to time. In this report, results of the bilateral interlaboratory comparison in pressure area in hydraulic media up to 50 MPa gauge between UME (Turkey) and BOM (The FYR of Macedonia) are presented. The artefact used for the comparison was a digital pressure calibrator and its drift was taken into account in the calculation. Results show that all En values lie in acceptable limits. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on the EURAMET.M.FF-K4.2.2014 volume comparison at 100 μL—calibration of micropipettes

    NASA Astrophysics Data System (ADS)

    Batista, Elsa; Matus, Michael; Metaxiotou, Zoe; Tudor, Maria; Lenard, Elzbieta; Buker, Oliver; Wennergren, Per; Piluri, Erinda; Miteva, Mariana; Vicarova, Martina; Vospĕlová, Alena; Turnsek, Urska; Micic, Ljiljana; Grue, Lise-Lote; Mihailovic, Mirjana; Sarevska, Anastazija

    2017-01-01

    During the EURAMET TC-F meeting of 2014 and following the finalization of CCM.FF-K4.2.2011 comparison, it was agreed to start a Regional Key Comparison (KC) on volume measurements using two 100 μL micropipettes (piston pipettes) allowing the participating laboratories to assess the agreement of their results and uncertainties. Two 100 μL micropipettes were tested by 15 participants. One participant was not a member or associate member of the BIPM and was be removed from this report. The comparison started in July 2015 and ended in March 2016. The Volume and Flow Laboratory of the Portuguese Institute for Quality (IPQ) was the pilot laboratory and performed the initial and final measurements of the micropipettes. The micropipettes showed a stable volume during the whole comparison, which was confirmed by the results from the pilot laboratory. The original results of all participant NMIs were corrected to the standard atmospheric pressure in order to compare results under the same calibration conditions, and the contribution of the 'process-related handling contribution' was added to the uncertainty budget of each participant. In general the declared CMCs are in accordance with the KCDB. For the micropipette 354828Z, two laboratories had inconsistent results. For micropipette 354853Z, three laboratories had inconsistent results. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. KEY COMPARISON: CCQM-K28: Tributyltin in sediment

    NASA Astrophysics Data System (ADS)

    Wolff Briche, Céline S. J.; Wahlen, Raimund; Sturgeon, Ralph E.

    2006-01-01

    Key comparison CCQM K-28 was undertaken to assess the measurement capabilities for quantitation of (C4H9)3Sn+ (TBT) in a prepared marine sediment by National Metrology Institutes (NMIs), which are members of the Comité Consultatif pour la Quantité de Matière (CCQM). It follows a previous pilot study, CCQM-P18. [1, 2] This exercise was sanctioned by the 8th CCQM meeting, 18-19 April 2002, as an activity of the Inorganic Analysis Working Group and was jointly coordinated by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and LGC, UK. Eight NMIs initially indicated their interest, with seven ultimately submitting their results. All NMIs relied on isotope dilution mass spectrometry using a species-specific 117Sn-enriched TBT standard, which was supplied by LGC. No analytical methodology was prescribed for this study. As a result, a variety of extraction approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with ethylation and direct sampling. Detection techniques included ICP-MS (coupled to GC or HPLC for the separation of Sn species) and GC-MS. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  6. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    NASA Astrophysics Data System (ADS)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on CCT-K6: Comparison of local realisations of dew-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.

    2015-01-01

    A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in January and February 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM7 (Z7) and BIPM9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V, at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 31 of January 2016. UNML - UBIPM = + 0.22 μV uc = 1.35 μV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Power, O.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in February and March 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMC (ZC), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final resultof the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V,at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 24 February 2015. UNML - UBIPM = - 0.82 mV; uc = 1.35 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out in February and March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_4 (Z4) and BIPM_5 (Z5), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 10 March 2014. UNML - UBIPM = -0.64 µV uc = 1.35 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to

  12. KEY COMPARISON: Results of the APMP Pressure key comparison APMP.M.P-K1c in gas media and gauge mode from 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, A. K.; Woo, Sam Yong; Fitzgerald, Mark; Man, John; Ooiwa, Akira; Jescheck, M.; Jian, Wu; Fatt, Chen Soo; Chan, T. K.; Moore, Ken; El-Tawil, Alaaeldin A. E.

    2003-01-01

    laboratories have primary standards [Category (I)], the remaining five laboratories are placed in Category (II). The obtained data were compiled and processed under the same program as per the Consultative Committee for Mass and Related Quantities (CCM)/BIPM guidelines. From the data of Category (I), we evaluated the APMP reference value as a function of p'/MPa. Then, we estimated the relative difference of the A'p' values with reference to the APMP reference value for all participating laboratories and we observed that they agree well within their expanded uncertainties. We further estimated the effective area at null pressure and at 23°C (A'0/mm2) and the pressure distortion coefficient (lambda'/MPa-1) of the transfer standard for all the participating laboratories. We then estimated the relative deviation of the A'0/mm2 from the reference value for all eleven laboratories and compared this with their estimated expanded uncertainties. The result is once again extremely encouraging and all these eleven laboratories are agreeing within their estimated maximum expanded uncertainties. We also estimated the degree of equivalence between any two participating laboratories following a matrix mechanism. This once again agrees extremely well within the estimated relative standard uncertainty, which is derived for the two participating laboratories. Finally, a new method has been introduced to evaluate these results and establish a link to CCM.P-K1c and EUROMET.M.P-K2 at two nominal pressures, near 1 MPa and 4 MPa. Again the results show an agreement of all participating laboratories in the present comparison to within the estimated expanded uncertainties using a coverage factor k = 2. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the Mutual

  13. Comparison of the Josephson Voltage Standards of the DMDM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Cincar Vujovic, T.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Directorate of Measures and Precious Metals (DMDM), Belgrade, Serbia, was carried out in June 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the DMDM using its Josephson standard with its own measuring device. Option A required the DMDM to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. Since no sufficiently stable voltage could be achieved in this configuration, a digital detector was used. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 1.5 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the IST-LPSR, Portugal and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Cardoso, J.

    2018-01-01

    A comparison of the standards for air kerma of the Instituto Superior Técnico, Laboratório de Proteção e Segurança Radiológica (IST-LPSR), Portugal and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in December 2015. The comparison result, evaluated as a ratio of the IST-LPSR and the BIPM standards for air kerma, is 1.0026 with a combined standard uncertainty of 1.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 1.1 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. KEY COMPARISON: CCQM-K61: Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA

    NASA Astrophysics Data System (ADS)

    Woolford, Alison; Holden, Marcia; Salit, Marc; Burns, Malcolm; Ellison, Stephen L. R.

    2009-01-01

    Key comparison CCQM-K61 was performed to demonstrate and document the capability of interested national metrology institutes in the determination of the quantity of specific DNA target in an aqueous solution. The study provides support for the following measurement claim: "Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA". The comparison was an activity of the Bioanalysis Working Group (BAWG) of the Comité Consultatif pour la Quantité de Matière and was coordinated by NIST (Gaithersburg, USA) and LGC (Teddington, UK). The following laboratories (in alphabetical order) participated in this key comparison. DMSC (Thailand); IRMM (European Union); KRISS (Republic of Korea); LGC (UK); NIM (China); NIST (USA); NMIA (Australia); NMIJ (Japan); VNIIM (Russian Federation) Good agreement was observed between the reported results of all nine of the participants. Uncertainty estimates did not account fully for the dispersion of results even after allowance for possible inhomogeneity in calibration materials. Preliminary studies suggest that the effects of fluorescence threshold setting might contribute to the excess dispersion, and further study of this topic is suggested Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2012-01-01

    As part of the on-going BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from February to March 2012. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_C (ZC) and BIPM_D (ZD), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson voltage standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 February 2012. UNML - UBIPM = +0.83 µV, uc = 1.35 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. The final result is impacted by the anomalous offset between the NSAI-NML results for the two transfer standards. The reason for this offset hasn't been determined. However, the difference remains within the total combined standard uncertainty. Therefore, the comparison result shows that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of

  17. COOMET.QM-K93 (COOMET 615/RU/13): key comparison in the field of measuring of the ethanol amount fraction in nitrogen (120 μmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Efremova, O. V.; Fatina, O. V.; Orshanskaia, A. A.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.

    2016-01-01

    The relevance of the COOMET.QM-K93 comparison is founded on paying particular attention to reliability of measurements which are performed during the medical examination of drivers of vehicles in order to assess the degree of alcoholic intoxication. Standard gas mixtures of ethanol in nitrogen in cylinders under pressure play a key role in providing metrological assurance of breath-alcohol analyzers. Participating laboratories: VNIIM and Ukrmetrteststandart. This comparison was carried out in 2014-2015. This supplementary comparison supports CMC claims for: ethanol in the range 50-500 μmol/mol in a matrix of either nitrogen or synthetic air. Results: The results are consistent with the reference values. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. KEY COMPARISON: EUROMET.M.D-K4/EUROMET Project 702: Comparison of the calibrations of high-resolution hydrometers for liquid density determinations

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Malengo, A.; Vámossy, C.; Bettin, H.; Toth, H.; do Céu Ferreira, M.; Gosset, A.; Madec, T.; Heinonen, M.; Buchner, C.; Lenard, E.; Spurny, R.; Akcadag, U.; Domostroeva, N.

    2008-01-01

    The main objective of the EUROMET project 702 was to compare the extent of comparability among eleven participating European national metrology institutes (INRIM (IT), OMH (HU), PTB (DE), BEV (AT), IPQ (PT), LNE (FR), MIKES (FI), GUM (PL), SMU (SK), UME (TR) and VNIIM (RU)) in performing calibrations of high-resolution hydrometers for liquid density determination in the range between 600 kg m-3 and 1300 kg m-3. By means of two groups of four similar transfer standards of excellent metrological characteristics, the participating laboratories were initially divided into two groups (petals) linked by the three density laboratories of INRIM, OMH and PTB. The results of the participating laboratories have been analyzed in this report and a good agreement was found between the results provided by most of the participants. These results allowed also determination of the degrees of equivalence of each NMI participating with the EUROMET_key comparison reference values (EU_KCRV); they will provide a basis for the review of the Calibration Measurement Capabilities (CMC) entries on hydrometer calibration, and they allowed the degree of equivalence between pairs of NMIs to be established. The Istitituto Nazionale di Ricerca Metrologica (INRIM), Italy, formerly IMGC-CNR, coordinated the project. Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Chayramy, R.; Solve, S.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from January to February 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_8 (Z8) and BIPM_9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 February 2013. UNML - UBIPM = -0.63 µV uc = 1.31 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according

  20. On-site comparison of Quantum Hall Effect resistance standards of the CMI and the BIPM: ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Kučera, Jan; Vojáčková, Lucie

    2017-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Czech Metrology Institute (CMI) and of the Bureau International des Poids et Mesures (BIPM) was made in April 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 6 parts in 1010 with a relative combined standard uncertainty uc = 25 × 10-10. Measurements of 10000 Ω/100 Ω and 100 Ω/1 Ω ratios agreed to 11 parts in 1010 with uc = 22 × 10-10 and to 33 parts in 1010 with uc = 32 × 10-10, respectively. The influence of the current reversal time has been systematically investigated in order to take into account possible errors due to the Peltier effect, which may be particularly large in 1 Ω standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Final report on comparison of hydraulic pressure balance effective area determination in the range up to 80 MPa

    NASA Astrophysics Data System (ADS)

    Grgec Bermanec, L.; Pantic, D.; Ramac, B.

    2018-01-01

    Bilateral comparison was organized between the laboratory for process measurement of the Croatian Metrology Institute (HMI/FSB-LPM) and the pressure laboratory of the Directorate of Measures and Precious Metals of the Republic of Serbia (DMDM). Laboratory for process measurement of HMI acted as the pilot laboratory. The aim of the comparison was to evaluate the degree of equivalence in the determination of effective area and elastic distortion coefficient, considering respective uncertainties of the two laboratories. Measurements were done on the pressure balance in gauge mode, with oil as transmitting medium, in the gauge pressure range 10–80 MPa. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Final report on SIM.T-S5: comparison of the calibration of 100 Ω platinum resistance thermometers

    NASA Astrophysics Data System (ADS)

    del Campo, D.; García, S.; Velasquez, A.; Medrano, J. A.; Solano, A.; Torres, H. E.

    2015-01-01

    An International Comparison on industrial Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Panama, Honduras, El Salvador, Costa Rica and Nicaragua began in 2013 and was successfully completed in 2014. Two PRTs were circulated (hand carried) and compared in the range from -38.8 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, acted as the pilot laboratory providing the reference value of the comparison. The thermometers have shown an acceptable behavior throughout the comparison, therefore the results can be considered valid for comparing the measurement capabilities of the participant laboratories. The equivalence between the participant laboratories in the calibration of platinum resistance thermometers by comparison in the range from -38,8 °C up to 250 °C has been demonstrated in almost all cases. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report on AFRIMETS comparison of liquid in glass thermometer calibrations from -35 °C to 250 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans; Kebede Ejigu, Efrem; Madiba, Tshifhiwa; du Clou, Sven; Chibaya, Blessing; Mwazi, Victor; Kajane, Tebogo; Mundembe, Victor; Kwong, Christian Ng Ha; Madeleine, Gilbert

    2017-01-01

    A Regional Metrology Organization (RMO) supplementary comparison of liquid in glass thermometer (AFRIMETS.T-S5) was carried out by the National Metrology Institute of South Africa (NMISA), Zimbabwe Scientific & Industrial Research & Development Centre—National Metrology Institute (SIRDC-NMI), Zambia Bureau of Standards (ZABS), Botswana Bureau of Standards (BOBS), Namibian Standards Institute (NSI), Mauritius Standards Bureau (MSB) and Seychelles Bureau of Standards (SBS) between January and September 2016. The temperature range of the inter comparison is -35 °C to 250 °C. The results of this comparison are reported here, along with descriptions of the Artefacts used. This report also presents the uncertainty budget of each participant. The results are analysed and normalized error (En) values are reported. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. KEY COMPARISON: CCEM.RF-K18.CL (GT-RF/00-1): Noise in 50 Ω coaxial line at frequencies up to 1 GHz

    NASA Astrophysics Data System (ADS)

    Eiø, Christopher; Adamson, David; Randa, James; Allal, Djamel; Uzdin, Rinadij

    2006-01-01

    A measurement comparison of noise temperature has been carried out between four national metrology laboratories in coaxial line at 30 MHz, 60 MHz and 1 GHz. The identification of this intercomparison is CCEM.RF-K18.CL. Two noise sources have been measured. The following four national laboratories participated in this intercomparison: NPL (United Kingdom), NIST (United States of America), BNM-LNE (France) and VNIIFTRI (Russia). The National Physical Laboratory (UK) acted as the pilot laboratory for the comparison. It can be seen that there is generally good agreement between the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Bilateral comparison of 1 V and 10 V standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Simionescu, M.; Cîrneanu, L.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Institut National de Metrologie (INM), Bucharest, Romania, was carried out from August to October 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_8 (Z8), were transported by freight to INM. At INM, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at INM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by INM, at the level of 1.018 V and 10 V, at INM, UINM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 6 September 2013. UINM - UBIPM = -0.014 µV uc = 0.051 µV, at 1 V UINM - UBIPM = -0.43 µV uc = 0.34 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at INM, based on KJ-90, and the uncertainty related to the comparison. These are satisfactory results. The comparison results show that the voltage standards maintained by INM and the BIPM were equivalent, within the comparison uncertainty, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual

  6. KEY COMPARISON Update of the BIPM.RI(II)-K1.Tc-99m comparison of activity measurements for the radionuclide 99mTc to include new results for the LNE-LNHB and the NPL

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Moune, M.; Johansson, L.; Keightley, J.

    2010-01-01

    In 2007 and 2008 respectively, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of 99mTc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNHB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. Bilateral Comparison of 1 V and 10 V Standards between the SMD (Belgium) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Vlad, D.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Service Métrologie—Metrologische Dienst (SMD), Brussel, Belgium, was carried out from October to November 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to SMD and also back to BIPM. At SMD, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at SMD, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by SMD, at the level of 1.018 V and 10 V, at SMD, USMD, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 November 2014. USMD - UBIPM = 0.14 mV; uc = 0.07 mV, at 1 V USMD - UBIPM = 0.09 mV; uc = 0.49 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at SMD, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Bilateral Comparison of 1 V and 10 V Standards between the JV (Norway) and the BIPM, January to February 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Sengebush, F.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Justervesenet (JV), Kjeller, Norway, was carried out from January to February 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to JV and also back to BIPM. At JV, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at JV, withthe Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by JV, at the level of 1.018 V and 10 V, at JV, UJV, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 28 January 2015. UJV - UBIPM = 0.23 μV uc = 0.03 μV , at 1 V UJV - UBIPM = 0.63 μV uc = 0.28 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at JV, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Bilateral Comparison of 1 V and 10 V Standards between the NIMT (Thailand) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute of Metrology (Thailand), NIMT, was carried out from October to December 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPM6 (Z6), were transported by freight to NIMT and back to BIPM. At NIMT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIMT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by NIMT, at the level of 1.018 V and 10 V, at NIMT, UNIMT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 November 2014. UNIMT - UBIPM = 0.16 mV; uc = 0.14 mV, at 1 V UNIMT - UBIPM = - 0.03 mV; uc = 0.11 mV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIMT, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Bilateral Comparison of 1 V and 10 V Standards between the NIS (Egypt) and the BIPM, August to September 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Abdel Mageed, Hala M.; Aladdin, Omar M.; Raouf, M. Helmy A.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMB (ZB) and BIPMC (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, UNIS, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 7 September 2014. UNIS - UBIPM = 0.09 µV uc = 0.08 µV, at 1 V UNIS - UBIPM = 0.22 µV uc = 0.14 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM

  11. Report to the CCT on COOMET comparison COOMET.T-K3.1 (previously COOMET.T-S1): Key regional comparison of the national standards of temperature in the range from the triple point of water to the freezing point of zinc

    NASA Astrophysics Data System (ADS)

    Pokhodun, A. I.

    2010-01-01

    In the framework of the CIPM MRA, a first COOMET comparison "Comparison of the ITS-90 realizations in the range from 0.01 °C to 429.7485 °C (from the triple point of water to the freezing point of zinc)", registered in the KCDB under the identifier "COOMET.T-K3", was carried out in 2005-2007. Four national metrology institutes took part in this comparison: VNIIM (Russian Federation), SMU (Slovakia), BelGIM (Republic of Belarus) and NSC IM (Ukraine), and two of them (VNIIM and SMU) ensured the linkage with key comparisons CCT-K3 and CCT-K4, in order to disseminate the metrological equivalence to the measurement standards of NSC IM and BelGIM. NSC IM, however, had to withdraw its results, and at the meeting of Technical Committee T-10 of COOMET it was decided to carry out a supplementary bilateral comparison between VNIIM and the NSC IM for realization of the ITS-90 in the same range of temperature. This was registered in the KCDB under the identifier COOMET.T-S1 and measurements were performed in 2008-2009. From the results presented in this report, it is possible to draw the conclusion that the COOMET supplementary comparison COOMET.T-S1 demonstrates the CMC uncertainties claimed by the NSC IM for the melting point of gallium 0.236 mK (k = 2), and the freezing points of indium 1.040 mK (k = 2), tin 0.858 mK (k = 2) and zinc 0.944 mK (k = 2). In September 2012 the Working Group on key Comparisons (WG 7) of the CCT upgraded this comparison to a COOMET key comparison of the 'CCT-K3' type. It is now identified as COOMET.T-K3.1. In April 2013 this report was superseded by item 03006 in the Technical Supplement of 2013. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. Final report of the SIM.QM-S7 supplementary comparison, trace metals in drinking water

    NASA Astrophysics Data System (ADS)

    Yang, Lu; Nadeau, Kenny; Gedara Pihillagawa, Indu; Meija, Juris; Grinberg, Patricia; Mester, Zoltan; Valle Moya, Edith; Solís González, Faviola Alejandra; del Rocio Arvizu Torres, María; Yañez Muñoz, Oscar; Velina Lara-Manzano, Judith; Mazzitello, Gisela; Prina, Pedro; Acosta, Osvaldo; Napoli, Romina; Pérez Zambra, Ramiro; Ferreira, Elizabeth; Dobrovolskiy, Vladimir; Aprelev, Aleksei; Stakheev, Aleksei; Frolov, Dmitriy; Gusev, Leonid; Ivanova, Veronika; Näykki, Teemu; Sara-Aho, Timo; Venegas Padilla, Jimmy; Acuña Cubillo, Carlos; Bremmer, Dwyte; Freemantle, Ruel; Taebunpakul, Sutthinun; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Kaewkhomdee, Nattikarn; Thiengmanee, Usana; Tangjit, Tararat; Buzoianu, Mirella; Alejandro Ahumada Forigua, Diego; Abella Gamba, Johanna Paola; Alfredo Chavarro Medina, Luis; Sobina, Egor; Tabatchikova, Tatyana; Alexopoulos, Charalambos; Kakoulides, Elias; Delgado, Mabel; Flores, Liliana; Knox, Saira; Siewlal, Kester; Maharaj, Avinash

    2018-01-01

    SIM.QM-S7 was performed to assess the analytical capabilities of National Metrology Institutes (NMIs) and Designated Institutes (DIs) of SIM members (or other regions) for the accurate determination of trace metals in drinking water. The study was proposed by the coordinating laboratories National Research Council Canada (NRC) and Centro Nacional de Metrologia (CENAM) as an activity of Inorganic Analysis Working Group (IAWG) of Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). Participants included 16 NMIs/DIs from 15 countries. No measurement method was prescribed by the coordinating laboratories. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S7 Supplementary Comparison provides NMIs/DIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Final report on regional supplementary comparison SIM.M.FF-S5: Volume of liquids at 50 mL

    NASA Astrophysics Data System (ADS)

    Morales, Abed; Malta, Dalni; Kornblit, Fernando; Ramírez, Ruben R.; Arias, Roberto; Trujillo, Sonia

    2012-01-01

    A regional supplementary comparison for the volume of liquid at 50 mL was conducted during October 2009 to June 2010 between the SIM members CENAM, INTI, INMETRO, INDECOPI and INTN. The transfer standard consisted of two 50 mL glass pycnometers, of the Gay Lussac type. CENAM acted as the pilot, collected the measurement results, analyzed the data and produced the comparison report. The median of all participants' results was used to calculate the regional comparison reference value because the result for one of the two pycnometers in one laboratory failed the chi-squared test at the 0.05 probability level. The measurements reported by the participants show an excellent overlap in four out of the five NMIs (-34×10-6 < Di < 29×10-6). The degree of equivalence obtained herein will be taken into account for the preparation of calibration and measurement capabilities claims from the participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report on APMP.M.P-S3: Results of the supplementary comparison in gas media in the range 1.77 MPa to 6.8 MPa

    NASA Astrophysics Data System (ADS)

    Owen, N.; Bergoglio, M.

    2013-01-01

    This report provides the results of the supplementary bilateral comparison APMP.M.P-S3 between NMI Australia (NMIA) and INRIM, Italy executed from November 2010 to November 2011. NMIA acted as the pilot laboratory and provided a Ruska G series piston gauge as the transfer standard, with a nominal area 16.8 mm2 requiring a nominal load of 12 kg to balance a pressure of 7.0 MPa. The purpose of this supplementary bilateral comparison was to provide data for linking NMIA to CCM.P-K1.c in the pressure range greater than 4 MPa to extend the range covered by key comparison APMP.M.P-K1c. The original protocol called for the pressure range from 80 kPa to 6.80 MPa. Both participants agreed to limit this comparison range to 1.77 MPa to 6.50 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Subsequent bilateral comparison to CCT-K3, CIPM key comparison CCT-K3.1: Comparison of standard platinum resistance thermometers at the triple point of water (T = 273.16 K) and at the melting point of gallium (T = 302.9146 K)

    NASA Astrophysics Data System (ADS)

    Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.

    2011-01-01

    A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Final report on APMP.M.M.K4.1—bilateral comparison of 1 kg stainless steel mass standards between KRISS and A*STAR

    NASA Astrophysics Data System (ADS)

    Chung, J. W.; Lee, S. M.; Lee, S. J.

    2017-01-01

    This report describes a bilateral comparison of 1 kg stainless steel mass standard between the Korea Research Institute of Standards and Science (KRISS), and the National Measurement Centre, Agency for Science, Technology and Research (A*STAR), Singapore, which is registered in the BIPM KCDB as APMP.M.M-K4.1. This nominal value was chosen as it followed the nominal value of CCM.M-K4. This bilateral comparison was piloted by KRISS. The transfer weight was delivered to A*STAR from KRISS in April 2015 and received back from A*STAR in October 2015. A*STAR are aiming to improve their calibration measurement capability (CMC) for mass of 1 kg. KRISS participated in both this comparison and CCM.M-K4, providing a link between the A*STAR result and the KCRV of CCM.M-K4. The final report of this comparison is given in this document. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Linking results of key and supplementary comparisons of AC/DC voltage transfer references

    NASA Astrophysics Data System (ADS)

    Velychko, Oleh

    2018-04-01

    A regional key comparison (KC) COOMET.EM-K6.a and a supplementary comparison (SC) COOMET.EM-S1 of AC/DC voltage transfer references were conducted between participating laboratories from the Eurasian region. Measurements were made over the period 2004-2014. The results showed good agreement between all but one of the participating laboratories. The proposed procedure of linking results of key and SCs of regional metrology organization of AC/DC voltage transfer references is presented. Linking results is realized for COOMET.EM-K6.a and CCEM-K6.a KCs, and for COOMET.EM-K6.a KC and COOMET.EM-S1 SC.

  18. EURAMET.T-K7 Key Comparison of Water Triple-Point Cells

    NASA Astrophysics Data System (ADS)

    Peruzzi, A.; Bosma, R.; Kerkhof, O.; Rosenkranz, P.; Del Campo Maldonado, M. D.; Strnad, R.; Nielsen, J.; Anagnostou, M.; Veliki, T.; Zvizdic, D.; Grudnewicz, E.; Nedea, M.; Neagu, D. M.; Steur, P.; Filipe, E.; Lobo, I.; Antonsen, I.; Renaot, E.; Heinonen, M.; Weckstrom, T.; Bojkovski, J.; Turzo-Andras, E.; Nemeth, S.; White, M.; Tegeler, E.; Dobre, M.; Duris, S.; Kartal Dogan, A.; Uytun, A.; Augevicius, V.; Pauzha, A.; Pokhodun, A.; Simic, S.

    2011-12-01

    The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the "mother" comparison CCT-K7 is discussed in detail.

  19. Final report on VMI-NMISA bilateral comparison APMP.T-K3.1: Realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans

    2012-01-01

    agree with the CCT-K3 reference values at these fixed points. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. International comparison CCQM-K101: oxygen in nitrogen—a track B comparison and that the matrix contains argon

    NASA Astrophysics Data System (ADS)

    Zhou, Z.; Han, Q.; Wang, D.; Macé, T.; Kipphardt, H.; Maiwald, M.; Tuma, D.; Uehara, S.; Akima, D.; Shimosaka, T.; Jung, J.; Oh, S.-H.; van der Veen, A.; van Wijk, J. I. T.; Ziel, P. R.; Konopelko, L.; Valkova, M.; Mogale, David M.; Botha, A.; Brewer, P.; Murugan, A.; Doval Minnaro, M.; Miller, M.; Guenther, F.; Kelly, M. E.

    2016-01-01

    This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. KEY COMPARISON: CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

    NASA Astrophysics Data System (ADS)

    Seah, M. P.

    2008-01-01

    weighted standard deviations of the means from table 6. This is provided in table 8. Graphical plots of equivalence from tables 6 and 8 are provided in figure 1 and equivalence statements are presented in Annex A. Additional XPS and XRR data from NMIJ for K32 were withdrawn from the KCRV evaluation and are given in Annex B. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. International comparison CCQM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Oudwater, Rutger J.; Fioravante, Andreia L.; Augusto, Cristiane R.; Coutinho Brum, Mariana; Uehara, Shinji; Akima, Dai; Bae, Hyun Kil; Kang, Namgoo; Woo, Jin-Chun; Liaskos, Christina E.; Rhoderick, George C.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique; Brewer, Paul J.; Brown, Andrew S.; Bartlett, Sam; Downey, Michael L.; Konopelko, L. A.; Kolobova, A. V.; Pankov, A. A.; Orshanskaya, A. A.; Efremova, O. V.

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare primary standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as a track A key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities using the flexible scheme, and for propane under the default scheme. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results but one are within +/- 0.2 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report on bilateral supplementary comparison APMP.M.P-S5 in hydraulic gauge pressure from 1 MPa to 10 MPa

    NASA Astrophysics Data System (ADS)

    Yue, J.; Yang, Y.; Sabuga, W.

    2016-01-01

    This report summarizes the results of the Asia-Pacific Metrology Programme (APMP) supplementary comparison APMP.M.P-S5 for hydraulic gauge pressure in the range of 1 MPa to 10 MPa, which is a bilateral comparison carried out at the National Institute of Metrology, China (NIM) and the Physikalisch-Technische Bundesanstalt, Germany (PTB) during the period June 2014 to June 2015. NIM piloted the comparison and provided the transfer standard, which was a piston-cylinder assembly (PCA) of 1 cm2 nominal effective area built in a hydraulic pressure balance manufactured by Fluke Corporation. The laboratory standards of NIM and PTB are both hydraulic pressure balances equipped with PCAs, of which the nominal effective area is 1 cm2 for NIM and 5 cm2 for PTB. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards of NIM and PTB in the range of 1 MPa to 10 MPa are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Joung, W.; Gam, K. S.; Achmadi, A.; Trisna, B. A.

    2016-01-01

    The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. SUPPLEMENTARY COMPARISON: Final report of the bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B between PTB and NIMT

    NASA Astrophysics Data System (ADS)

    Sanponpute, Tassanai; Meesaplak, Apichaya; Herrmann, Konrad; Menelao, Febo

    2009-01-01

    The bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B was arranged by the National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison was to confirm the calibration and measurement capabilities of NIMT in hardness measurement. The period of measurement covered March to August 2009. There were two sets of artefacts: scale A artefact set and scale B artefact set. The scale A artefact set consisted of seven hardness blocks: 35 HRA, 40 HRA, 55 HRA, 60 HRA, 70 HRA, 80 HRA, 85 HRA. The artefact set for scale B consisted of nine hardness blocks: 25 HRB, 30 HRB, 40 HRB, 50 HRB, 60 HRB, 70 HRB, 80 HRB, 90 HRB, 100 HRB. Laboratories had to ensure that the primary Rockwell hardness machines passed the verification process according to ISO 6508-3. Then participants measured the hardness value by making ten indentations in a designated area of each artefact block. Hardness measurement results and uncertainty budget were then reported to the pilot laboratory and were used to compute the degrees of equivalence in terms of the Comparison Reference Value (CRV) and En ratio. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Bilateral comparison of 1 V and 10 V standards between the DEFNAT (Tunisia) and the BIPM February to March 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Ben Salah, B.; Mallat, A.; Abene, L.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Electrique, DEFNAT (Tunisia), was carried out from February to March 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMC (ZC) and BIPM6 (Z6), were transported by freight to DEFNAT and back to BIPM. In order to keep the Zeners powered during their transportation phase, a BIPM in-house voltage stabiliser was connected in parallel to the internal battery. The voltage stabiliser consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for 10 consecutive days. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DEFNAT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT, UDEFNAT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 26th of February 2016. UDEFNAT - UBIPM = + 0.07 μV uc = 0.04 μV, at 1.018 V UDEFNAT - UBIPM = + 0.38 μV uc = 0.10 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  7. International comparison Euramet.QM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    Wouter van der Hout, J.; van der Veen, Adriaan M. H.; Ziel, Paul R.; Kipphardt, Heinrich; Tuma, Dirk; Maiwald, Michael; Fernández, Teresa E.; Gómez, Concepción; Cieciora, Dariusz; Ochman, Grzegorz; Dias, Florbela; Silvino, Victor; Macé, Tatiana; Sutour, Christophe; Marioni, Fabrice; Ackermann, Andreas; Niederhauser, Bernhard; Fükő, Judit; Büki, Tamás; Nagyné Szilágyi, Zsófia; Tarhan, Tanıl; Engin, Erinç

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within +/- 1 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. SUPPLEMENTARY COMPARISON: Final report on supplementary comparison APMP-T-S3-03 of industrial platinum resistance and liquid in glass thermometers from -40 °C to 250 °C

    NASA Astrophysics Data System (ADS)

    Norranim, Uthai; Nguyen, Mong Kim; Ballico, Mark J.

    2007-01-01

    Industrial thermometers such as industrial platinum resistance thermometers (iprts) and liquid-in-glass thermometers (LIGTs) are widely used in industry. Because Key Comparisons are limited to direct realizations of ITS-90, and not all APMP NMIs have participated in them, the national metrology institutes (NMIs) of Thailand and Australia (NIMT and NIMA) organized an APMP supplementary comparison to support the approval of CMCs (calibration and measurement capabilities) for these laboratories. The comparison, performed in 2003, covered the range from -40.0 °C to 250.0 °C, using IPRTs (Hart Scientific 5626-12-S), total immersion (ASTM 62C, 120C) and partial immersion (ASTM 40C) LIGTs. Ten NMIs from the APMP: KIM-LIPI (Indonesia), ITDI (Philippines), MSL (New Zealand), NBSM (Nepal), NMIA (Australia), NIMT (Thailand), SCL (Hong Kong), SIRIM (Malaysia), SPRING (Singapore) and VMI (Vietnam) were divided into two loops to shorten the circulation time, and these were linked by the two pilot laboratories. This report describes details of the artifacts, the circulation schedule, the measurement procedures, the results submitted by participants, uncertainties and the analysis of the results. Reference values calculated using simple mean, median and weighted mean were consistent with each other, but as the Birge criterion was satisfied, the weighted mean with its lower uncertainty was adopted. The artifacts were found to be stable over the comparison and the results of the loop linking labs consistent, allowing an uncertainty of 2 mK to 4 mK to be achieved for the IPRT reference value and 10 mK to 20 mK for the LIGT reference values. These uncertainties allowed the comparison data to be used to adequately test the uncertainties of all the participant laboratories, and hence to directly support their CMC claims. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database

  9. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. International comparison CCQM-K111.1—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capability of preparing Primary Standard gas Mixtures (PSMs), performing the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this subsequent key comparison is classified as a track B key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities for propane under the default scheme. The artefact was a binary mixture of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The result of the participating laboratory is consistent with the key comparison reference value within the respective expanded uncertainties and deviates less than 0.1 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report on EURAMET.QM-S6/1195: Bilateral comparison of liquefied hydrocarbon mixtures in constant pressure (piston) cylinders

    NASA Astrophysics Data System (ADS)

    Brown, Andrew S.; Downey, Michael L.; Milton, Martin J. T.; van der Veen, Adriaan M. H.; Zalewska, Ewelina T.; Li, Jianrong

    2013-01-01

    Traceable liquid hydrocarbon mixtures are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas) and LNG (liquefied natural gas), thus meeting the needs of an increasingly large European industrial market. The development of traceable liquid hydrocarbon standards by National Measurement Institutes (NMIs) was still at a relatively early stage at the time this comparison was proposed in 2011. NPL and VSL, who were the only NMIs active in this area, had developed methods for the preparation and analysis of such standards in constant pressure (piston) cylinders, but neither laboratory had Calibration and Measurement Capabilities (CMCs) for these mixtures. This report presents the results of EURAMET 1195, the first comparison of liquid hydrocarbon mixtures between NMIs, which assessed the preparation and analytical capabilities of NPL and VSL for these mixtures. The comparison operated between August 2011 and January 2012. Each laboratory prepared a liquid hydrocarbon standard with nominally the same composition and these standards were exchanged for analysis. The results of the comparison show a good agreement between the laboratories' results and the comparison reference values for the six components with amount fractions greater than 1.0 cmol/mol (propane, propene, iso-butene, n-butane, iso-butane and 1-butene). Measurement of the three components with lower amount fractions (1,3-butadiene, iso-pentane and n-pentane) proved more challenging. In all but one case, the differences from the comparison reference values for these three components were greater than the expanded measurement uncertainty. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual

  12. Key comparison study on peptide purity—synthetic human C-peptide

    NASA Astrophysics Data System (ADS)

    Josephs, R. D.; Li, M.; Song, D.; Westwood, S.; Stoppacher, N.; Daireaux, A.; Choteau, T.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Flatschart, R.; Borges Oliveira, R.; Melanson, J. E.; Ohlendorf, R.; Henrion, A.; Kinumi, T.; Wong, L.; Liu, Q.; Oztug Senal, M.; Vatansever, B.; Ün, I.; Gören, A. C.; Akgöz, M.; Quaglia, M.; Warren, J.

    2017-01-01

    . More detailed studies on the identification/quantification of peptide related impurities and the hydrolysis efficiency revealed that the integrity of the impurity profile of the related peptide impurities obtained by the participant is crucial for the impact on accuracy of the hCP mass fraction assignment. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most exhaustive and elaborate set of results is taken for the calculation of the KCRVPepImp. The KCRVPepImp for the peptide related impurity mass fractions of the material was 83.3 mg/g with a combined standard uncertainty of 1.5 mg/g. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in many cases only a very small number of impurities have been identified and quantified resulting in an underestimation of the peptide related impurity mass fractions. The approach to obtain a KCRVhCP for the mass fraction of hCP is based on a mass balance calculation that takes into account the most exhaustive and elaborate set of results for the peptide related impurities KCRVPepImp, the TFA mass fraction value, water and other minor counter ions obtained by the coordinating laboratories. Differences in the quality of the results obtained for both peptides related impurity mass fractions and hCP mass fractions are better weighted and reflected in smaller uncertainties. The KCRVhCP for CCQM-K115 is 801.8 mg/g with a corresponding combined standard uncertainty of 3.1 mg/g. In general, mass balance approaches show smaller uncertainties than PICAA approaches and the majority of results obtained by the PICAA approach are in agreement because of larger corresponding uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The

  13. Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Zivkovic, V.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Directorate of Measures and Precious Metals (DMDM), Beograd, Serbia, was carried out from January to March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMA (ZA), were transported by freight to DMDM. At DMDM, the reference standard for DC voltage is a Josephson Voltage Standard. The output electromotive force of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DMDM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DMDM, at the level of 1.018 V and 10 V, at DMDM, UDMDM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 13 February 2014. UDMDM - UBIPM = 0.094 µV uc = 0.072 µV, at 1 V UDMDM - UBIPM = 0.39 µV uc = 0.12 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DMDM, based on KJ-90, and the uncertainty related to the comparison. The results at the 10 V level are not covered by the uncertainties with a coverage factor of 2. After the distribution of the Draft A, the DMDM discovered that the pressure gauge was defective. Some considerations on the correction to apply on the comparison result and the corresponding uncertainties are presented in the report. Nevertheless, the above results fully cover the CMCs of DMDM which are significantly larger. No corrections for temperature and pressure are applied in calibrations for

  14. Key comparison CCPR-K1.a as an interlaboratory comparison of correlated color temperature

    NASA Astrophysics Data System (ADS)

    Kärhä, P.; Vaskuri, A.; Pulli, T.; Ikonen, E.

    2018-02-01

    We analyze the results of spectral irradiance key comparison CCPR-K1.a for correlated color temperature (CCT). For four participants out of 13, the uncertainties of CCT, calculated using traditional methods, not accounting for correlations, would be too small. The reason for the failure of traditional uncertainty calculation is spectral correlations, producing systematic deviations of the same sign over certain wavelength regions. The results highlight the importance of accounting for such correlations when calculating uncertainties of spectrally integrated quantities.

  15. Bilateral comparison of 1 V and 10 V standards between the NMISA (South Africa) and the BIPM April to June 2017 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Matlejoane, A. M.; Magagula, L.; Stock, M.

    2018-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the National Metrology Institute of South Africa, NMISA (South Africa), was carried out from April to June 2017. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPMB (ZB), were transported by freight to NMISA and back to BIPM. In order to keep the Zeners powered during their transportation phase, a voltage stabilizer developed by BIPM was connected in parallel to the internal battery. It consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for ten consecutive days. At NMISA, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NMISA, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NMISA, at the level of 1.018 V and 10 V, at NMISA, UNMISA, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference dates of the 19th and 18th of May 2017, respectively. UNMISA - UBIPM = + 0.07 μV uc = 0.02 μV, at 1.018 V UNMISA - UBIPM = + 0.001 μV uc = 0.34 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NMISA, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  16. EURAMET key comparison no. EURAMET.T-K1: realisations of the ITS-90 from 2.6 K to 24.5561 K, using rhodium-iron resistance thermometers

    NASA Astrophysics Data System (ADS)

    Gaiser, Christof; Fellmuth, Bernd; Steur, Peter; Szmyrka-Grzebyk, Anna; Manuszkiewicz, Henryk; Lipinski, Leszek; Peruzzi, Andrea; Rusby, Richard; Head, David

    2017-01-01

    In the temperature range from 0.65 K to 24.5561 K, the ITS-90 is defined by specified vapour-pressure equations for 3He and 4He and interpolation equations for a constant-volume gas thermometer using 3He or 4He. The definitions are given in sections 3.1 and 3.2 of the ITS-90 text, and methods for realising the scale in this range are outlined in chapters 4 and 5 of the Guide to the Realization of the ITS-90 (formerly Supplementary Information for the ITS-90). Direct realisations of the ITS-90 by these methods require relatively sophisticated apparatus and time-consuming experiments, and consequently they are rarely carried out. The situation is acceptable in practice only because rhodium-iron resistance thermometers (RIRTs) are available that, once calibrated, are able to maintain their calibrations reliably for long periods of time. They are the practical thermometers on which realisations of the ITS-90 are most accurately maintained, disseminated and compared. The key comparison EURAMET.T-K1 is therefore a comparison of calibrated RIRTs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the VSL, Netherlands and the BIPM in accelerator photon beams

    NASA Astrophysics Data System (ADS)

    Picard, S.; Burns, D. T.; Roger, P.; de Prez, L. A.; Jansen, B. J.; Pooter, J. A.

    2017-01-01

    A comparison of the dosimetry for accelerator photon beams was carried out between the Dutch Metrology Institute (VSL) and the Bureau International des Poids et Mesures (BIPM) from 23 September to 20 October 2014. The comparison was based on the determination of absorbed dose to water for three radiation qualities of the medical accelerator facilities of the National Physical Laboratory (United Kingdom). After establishing Draft B, the VSL discovered an error in the calculation of the correction factor for excess-heat linked to the VSL glass vessel used in the measurements at the NPL. The comparison results for the revised standard, reported as ratios of the VSL and the BIPM evaluations (and with the combined standard uncertainties given in parentheses), are 0.9959 (54) at 6 MV, 0.9958 (64) at 10 MV and 0.9991 (75) at 25 MV. This result is part of the on-going BIPM.RI(I)-K6 series of comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on COOMET.T-S1. Comparison of type S thermocouples at the freezing points of zinc, aluminium and copper 2014—2015

    NASA Astrophysics Data System (ADS)

    Pokhodun, A. I.; Ivanova, A. G.; Duysebayeva, K. K.; Ivanova, K. P.

    2015-01-01

    Regional comparison of type S thermocouples at the freezing points of zinc, aluminium and copper was initiated by COOMET TC1.1-10 (the technical committee of COOMET `Thermometry and thermal physics'). Three NMI take part in COOMET regional comparison: D I Mendeleev Institute for Metrology (VNIIM) (Russian Federation), National Scientific Centre (Institute of Metrology) (NSC IM, Ukraine), Republic State Enterprise (Kazakhstan Institute of Metrology) (KazInMetr, Republic of Kazakhstan). VNIIM (Russia) was chosen as the coordinator-pilot of the regional comparison. A star type comparison was used. The participants: KazInMetr and NSC IM constructed the type S thermocouples and calibrated them in three fixed points: zinc, aluminum and copper points, using methods of ITS-90 fixed point realizations. The thermocouples have been sent to VNIIM together with the results of the calibration at three fixed points, with the values of the inhomogeneity at temperature 200 °C and the uncertainty evaluations of the results. For calibration of thermocouples the same VNIIM fixed points cells were used. Participating laboratories repeated the calibration of thermocouples after its returning in zinc, aluminum and copper points to determine the stability of its results. In result of the comparison was to evaluate the equivalence of the type S thermocouples calibration in fixed points by NMIs to confirm corresponding lines of international website for NMI's Calibration and Measurement Capabilities (CMC). This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Report on the bilateral comparison between BIM (Bulgaria) and VSL (The Netherlands)

    NASA Astrophysics Data System (ADS)

    Dekker, Paul; Kunova, Angela; Dierikx, Erik

    2017-01-01

    A bilateral comparison has been organized between VSL, The Netherlands and BIM, Bulgaria in the field of spectral regular transmittance measurements. This comparison is registered as EURAMET project nr. 1073 and EURAMET.PR-K6.2 in the BIPM key comparison database. The aim of the comparison is to demonstrate the improvement of calibration measurement capabilities of BIM in this working field. If this comparison is successful, i.e. the results support the claimed improvement in uncertainties, the improved CMC's for BIM will be included in Appendix C of the CIPM mutual recognition arrangement (MRA). The results of this comparison are linked to key comparison CCPR K6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Consensus building for interlaboratory studies, key comparisons, and meta-analysis

    NASA Astrophysics Data System (ADS)

    Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza

    2017-06-01

    Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian

  1. Final report of CCQM-K130 nitrogen mass fraction measurements in glycine

    NASA Astrophysics Data System (ADS)

    Medvedevskikh, Maria; Krasheninina, Maria; do Rego, Eliane C. P.; Wollinger, Wagner; Monteiro, Tânia M.; de Carvalho, Lucas J.; Acco Garcia, Steve Ali; Haraldsson, Conny; Rodriguez, M. Alejandra; Rodriguez, Gabriela; Salvo, Karino; Gavrilkin, Vladimir; Kulyk, Sergij; Samuel, Laly

    2017-01-01

    CCQM key comparison K-130 in the field of nitrogen mass fracton has been performed by the Inorganic Analysis Working Group (IAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this key comparison CCQM-K130 is to support National Measurement Institutes (NMIs) and Designated Institutes (DIs) to demonstrate the validity of the procedures the employed for determination of nitrogen mass fraction in glycine. Mass fraction of nitrogen is very important pointer because the results of these measurements are often used for determination of protein mass fraction that is an important indicator of the quality of the vast majority of food products and raw materials, in particular dry milk powder. Proteins-enzymes catalyze chemical reactions, protein along with fats and carbohydrates is one of the indicators characterizing the energy value of food, so its definition is mandatory for all food products. The study material for this key comparison has been selected to be representative as one of the aminoacid - the simplest part of the protein. Glycine is an amino acid, single acid that does not have any isomers (melting point -290 °C specific heat of evaporation - 528,6 J/kg; specific melting heat - 981,1 J/kg; pKa - 2, 34, molar mass - 75,07 g/mol, density - 1,607 g/cm3). Ural Scientific Research Institute for Metrology (UNIIM) acted as the coordinating laboratory of this comparison. Nine NMIs participated in this key comparison and one NMI participated in Pilot study that was condacted in parallel. Report A contains the results of key comparison and pilot study. The results of Pilot study were excluded from the Report B Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM

  2. Final report of supplementary comparison AFRIMETS.AUV.A-S1: primary pressure calibration of LS2aP microphones according to IEC 61094-2, over the frequency range 1 Hz to 31.5 kHz.

    NASA Astrophysics Data System (ADS)

    Nel, R.; Barrera-Figueroa, S.; Dobrowolska, D.; Defilippo Soares, Z. M.; Maina, A. K.; Hof, C.

    2016-01-01

    This is the final report of the AFRIMETS.AUV-S1 comparison of the pressure sensitivity, modulus and phase, of LS2aP microphones in the frequency range 1 Hz to 31.5 kHz in accordance with IEC 61094-2. Six national metrology institutes from three different regional metrology organisations participated in the comparison for which two LS2aP microphones were circulated simultaneously to all the participants in a hybrid-star configuration. The comparison reference values were calculated as the weighted mean for modulus and phase for each individual microphone. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report of AFRIMETS.M.M-S6: supplementary comparison of 100 mg, 100 g 500 g, 1 kg and 5 kg stainless steel mass standards

    NASA Astrophysics Data System (ADS)

    Mautjana, R. T.; Molefe, P. T.; Mayindu, N. F.; Armah, M. N.; Ramasawmy, V.; Albasini, G. L.; Matali, S.; Richmond, H.; Rusimbi, V.; Kiwanuka, J.; Mutale, D. M.; Mutsimba, F.

    2018-01-01

    This report summarizes the results of AFRIMETS.M.M-S6 mass standards comparison conducted between eleven participating laboratories/countries. Two sets of five weights with nominal values 100 mg, 100 g, 500 g, 1 kg and 5 kg were used as the traveling standards. These nominal values were decided from the needs of participating laboratories submitted to the pilot laboratory through a questionnaire and agreed upon by all participants. The traveling standards were hand carried between laboratories starting from February 2014 and were received from the last participants in October 2014. The programme was coordinated by National Metrology Institute of South Africa (NMISA), who provided the travelling standards and reference values for the comparison. The corrections to the BIPM as-maintained mass unit [5] have insignificant influence on the results of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Uncertainty and Variability in Physiologically-Based Pharmacokinetic (PBPK) Models: Key Issues and Case Studies (Final Report)

    EPA Science Inventory

    EPA announced the availability of the final report, Uncertainty and Variability in Physiologically-Based Pharmacokinetic (PBPK) Models: Key Issues and Case Studies. This report summarizes some of the recent progress in characterizing uncertainty and variability in physi...

  5. Final report on supplementary comparison APMP.M.P-S7.TRI in hydraulic gauge pressure from 40 MPa to 200 MPa

    NASA Astrophysics Data System (ADS)

    Kobata, Tokihiko; Olson, Douglas A.; Eltawil, Alaaeldin A.

    2017-01-01

    This report describes the results of a supplementary comparison of hydraulic high-pressure standards at three national metrology institutes (NMIs); National Metrology Institute of Japan, AIST (NMIJ/AIST), National Institute of Standards and Technology (NIST), USA and National Institute for Standards (NIS), Egypt, which was carried out at NIST during the period May 2001 to September 2001 within the framework of the Asia-Pacific Metrology Programme (APMP) in order to evaluate their degrees of equivalence at pressures in the range 40 MPa to 200 MPa for gauge mode. The pilot institute was NMIJ/AIST. Three working pressure standards from the institutes, in the form of piston-cylinder assemblies, were used for the comparison. The comparison and calculation methods used are discussed in this report. From the cross-float measurements, the differences between the working pressure standards of each institute were examined through an evaluation of the effective area of each piston-cylinder assembly with its uncertainty. From the comparison results, it was revealed that the values claimed by the participating institutes, NMIJ, NIST, and NIS, agree within the expanded (k = 2) uncertainties. The hydraulic pressure standards in the range 40 MPa to 200 MPa for gauge mode of the three participating NMIs were found to be equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final report on APMP supplementary comparison of industrial platinum resistance thermometer for range -50 °C to 400 °C. (APMP.T-S6)

    NASA Astrophysics Data System (ADS)

    Ali, Nurulaini Md; Othman, Hafidzah; Ho, Mong-Kim; Yang, Inseok; Gabi, Victor; Zhang, Zhe; Sheng, Ying; Hu, Jing; Zhang, Jintao; Tsai, Shu-Fei; Liao, Su-Chuion; Shafiqul Alam, Md; Norranim, Uthai; Yaokulbodee, Charuayrat; Liedberg, Hans; Gamal Ahmed, Mohamed; Harba, Naser; Fuad Flaifel, Mustafa; Suherlan; Achmadi, Aditya; Haoyuan, Kho; Yan, Fan; Boon Kwee, Neoh; Thanh Binh, Pham; Ragay, Monalisa

    2017-01-01

    The National Metrology Laboratory, Malaysia (NML-SIRIM) had coordinated the Supplementary Comparison of Industrial Platinum Resistance Thermometer (IPRT) started from July 2009 until April 2011 together with the National Measurement Institute of Australia (NMIA) and Korea Research Institute of Standards and Science (KRISS). This comparison was opened to all APMP members and 16 participants had taken part in order to consolidate or improve their calibration and measurement capabilities (CMCs). Three units of artefacts 100-ohm IPRT belonging to NML-SIRIM, NMIA and KRISS were used and three loops of measurement were run in parallel to shorten the circulation time. The stability of artefacts was monitored with initial and final ice point measurement by each laboratory. The participants need to perform measurement at temperature points (0,-50,-30, 0, 100, 200, 300, 400,0) °C. All submitted data were compiled and adjusted at nominal temperature and by using the linkage from NMIA and KRISS as reference value for all three loops , the temperature deviation from participants from different loops can be compared. The approach of Birge Ratio for final exclusion comprised all the excluded results from the analysis of each loop and the measurement performance for each participant were summarized by the En number value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. International comparison of AC-DC current transfer standards

    NASA Astrophysics Data System (ADS)

    Heine, G.; Garcocz, M.; Waldmann, W.

    2017-01-01

    The measurements of the international comparison of ac-dc current transfer standards identified as EURAMET.EM-K12 started in June 2012 and were completed in December 2014. Twenty NMIs in the EURAMET region and one NMI in the AFRIMET region took part: BEV (Austria), CMI (Czech Republic), PTB (Germany), METAS (Switzerland), JV (Norway), UME (Turkey), GUM (Poland), IPQ (Portugal), CEM (Spain), INRIM (Italy), SP (Sweden), DANIAmet-MI-Trescal (Denmark), BIM (Bulgaria), MKEH (Hungary), SIQ (Slovenia), LNE (France), NSAI NML (Ireland), VSL (The Netherlands), NPL (United Kingdom), Metrosert (Estonia), NIS (Egypt). The comparison was proposed to link the National Metrology Institutes organised in EURAMET to the key comparison CCEM-K12. The ac-dc current transfer difference of each travelling standard had been measured at its nominal current 10 mA and 5 A at the following frequencies: 10 Hz, 55 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz. The test points were selected to link the results with the equivalent CCEM Key Comparison (CCEM-K12), through five NMIs participating in both EURAMET and CCEM key comparisons (PTB, JV, NPL, SP and BEV). The report shows the degree of equivalence in the EURAMET region and also the degree of equivalence with the corresponding CCEM reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. International comparison CCQM-K113—noble gas mixture

    NASA Astrophysics Data System (ADS)

    Lim, Jeong Sik; Lee, Jinbok; Moon, Dongmin; Tshilongo, James; Qiao, Han; Shuguo, Hu; Tiqiang, Zhang; Kelley, Michael E.; Rhoderick, George C.; Konopelko, L. A.; Kolobova, A. V.; Vasserman, I. I.; Zavyalov, S. V.; Gromova, E. V.; Efremova, O. V.

    2017-01-01

    Noble gases are one of the key elements used in the various processes of the bulbs industry, automotive industry, space industry, lasers industry, display industry as well as the semiconductor industry. Considering continuous growth, the provision of a reliable standard is required for those industries to improve their productivity. In this report, a result of the key comparison, CCQM-K113: noble gas mixture, is presented. Nominal amount-of-substance fractions of argon, neon, krypton, and xenon in helium are 20, 10, 2, and 1 cmol/mol, respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report on APMP.M.H-S3: Comparison on hardness measurement Rockwell scale A and B

    NASA Astrophysics Data System (ADS)

    Sanponpute, Tassanai; Meesaplak, Apichaya; Menelao, Febo; Chan, T. K.; Bahng, Gun-Woong; Titus, S. S. K.; Jain, S. K.

    2012-01-01

    The APMP.M.H-S3 Rockwell hardness intercomparison was initiated by NIMT, Thailand and the required protocol was prepared by NIMT and checked by Dr John Man, MNIA, Australia, in 2009. PTB, Germany, Standards and Calibration Laboratory (SCL), Hong Kong, National Physical Laboratory (NPLI), India, and Korea Research Institute of Standards and Science (KRISS), Korea, participated in this comparison. This comparison exercise was focused on the measurement range of 25 to 100 HRBW scale and 35 to 85 HRA scale. The round robin test was done during the period from April 2010 to October 2010. The participating laboratories have demonstrated the capability of the machine and the operating conditions according to ISO 6508 Part 3 to perform the measurements. However, SCL, Hong Kong, could demonstrate their capability to perform the measurements only according to ISO 6508 Part 2. The CMCs declared by the different laboratories lie in the range of 0.30 HRA to 0.40 HRA and 0.40 HRBW to 0.75 HRBW. The CMC declared by SCL for the Rockwell B scale is 1.5 HRBW for the reason described above. It is observed from the results that the measurement uncertainty is estimated not less than the CMCs declared by the laboratories. From the measurement results provided by all the participating laboratories, the En ratio was determined to establish the degrees of equivalence. The En ratio was calculated by including as well as by excluding the results of the laboratory which has performed the test according to ISO 6508 Part 2 in order to make sure that it does not affect the overall results. It is noticed that the En ratio was still found to remain less than 1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. SUPPLEMENTARY COMPARISON: COOMET.RI(II)-S1.Rn-222 (169/UA/98): Rn-222 volume activity comparison

    NASA Astrophysics Data System (ADS)

    Skliarov, V.; Röttger, A.; Honig, A.; Korostin, S.; Kuznetsov, S.; Lapenas, A.; Milevsky, V.; Ivaniukovich, A.; Kharitonov, I.; Sepman, S.

    2009-01-01

    According to a first program, a supplementary comparison of Rn-222 volume activity was drawn up as a bilateral supplementary comparison between NSC 'Institute of Metrology', Ukraine, and VNIIFTRI, Russia. It took place in March 2005. In April 2005, at the 5th meeting of COOMET held in Braunschweig (Germany), representatives of these institutes exchanged data which showed the comparability of the national standards of Ukraine and Russia for the check points. During the discussion of the procedure some other institutes decided to join the comparison program, which was extended to BelGIM (Belarus), PTB (Germany), VNIIM (Russia) and RMTC (Latvia). The national standards of volume activity of radon-222 were thus calibrated using one standard radon radiometer as the transfer standard. Results are shown in the Final Report of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by COOMET, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. Final report of APMP.QM-K46 ammonia in nitrogen at 30 μmol/mol level

    NASA Astrophysics Data System (ADS)

    Uehara, Shinji; Qiao, Han; Shimosaka, Takuya

    2017-01-01

    This report describes the results for a bilateral comparison of ammonia in nitrogen gas mixture. The nominal amount-of-substance fraction was 30 μmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Report on NIM-NMC bilateral comparison: SPRT calibration comparison from -190°C to 420°C

    NASA Astrophysics Data System (ADS)

    Sun, Jianping; Ye, Shaochun; Wang, Li; Zhang, Jintao; Kho, Haoyuan

    2016-01-01

    A bilateral comparison of local realization of the International temperature scale of 1990 (ITS-90) between National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from -190°C to 420°C. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key comparison 3 (CCT-K3) and facilitate the NMC's Calibration and measurement capabilities (CMCs) submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme (APMP) in 2009, and registered in the Key Comparison Database (KCDB) in 2010 as CCT-K3.2. NMC supplied two 25 Ω fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn and Zn fixed points, while the other one was used at the Ar and Hg fixed point. NMC measured them before and after NIM measurement. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 Average Reference Value (ARV) using NIM as a link are reported with expanded uncertainties at each measured fixed point. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Final report of CCQM-K136 measurement of porosity properties (specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous Al2O3

    NASA Astrophysics Data System (ADS)

    Sobina, E.; Zimathis, A.; Prinz, C.; Emmerling, F.; Unger, W.; de Santis Neves, R.; Galhardo, C. E.; De Robertis, E.; Wang, H.; Mizuno, K.; Kurokawa, A.

    2016-01-01

    CCQM key comparison K-136 Measurement of porosity properties (specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous Al2O3 has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The objective of this key comparison is to compare the equivalency of the National Metrology Institutes (NMIs) and Designated Institutes (DIs) for the measurement of specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous substances (sorbents, catalytic agents, cross-linkers, zeolites, etc) used in advanced technology. In this key comparison, a commercial sorbent (aluminum oxide) was supplied as a sample. Five NMIs participated in this key comparison. All participants used a gas adsorption method, here nitrogen adsorption at 77.3 K, for analysis according to the international standards ISO 15901-2 and 9277. In this key comparison, the degrees of equivalence uncertainties for specific adsorption, BET specific surface area, specific pore volume and pore diameter was established. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Angle comparison using an autocollimator

    NASA Astrophysics Data System (ADS)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report on mid-polarity analytes in food matrix: mid-polarity pesticides in tea

    NASA Astrophysics Data System (ADS)

    Sin, Della W. M.; Li, Hongmei; Wong, S. K.; Lo, M. F.; Wong, Y. L.; Wong, Y. C.; Mok, C. S.

    2015-01-01

    At the Paris meeting in April 2011, the CCQM Working Group on Organic Analysis (OAWG) agreed on a suite of Track A studies meant to support the assessment of measurement capabilities needed for the delivery of measurement services within the scope of the OAWG Terms of Reference. One of the studies discussed and agreed upon for the suite of ten Track A studies that support the 5-year plan of the CCQM Core Competence assessment was CCQM-K95 'Mid-Polarity Analytes in Food Matrix: Mid-Polarity Pesticides in Tea'. This key comparison was co-organized by the Government Laboratory of Hong Kong Special Administrative Region (GL) and the National Institute of Metrology, China (NIM). To allow wider participation, a pilot study, CCQM-P136, was run in parallel. Participants' capabilities in measuring mid-polarity analytes in food matrix were demonstrated through this key comparison. Most of the participating NMIs/DIs successfully measured beta-endosulfan and endosulfan sulphate in the sample, however, there is room for further improvement for some participants. This key comparison involved not only extraction, clean-up, analytical separation and selective detection of the analytes in a complex food matrix, but also the pre-treatment procedures of the material before the extraction process. The problem of incomplete extraction of the incurred analytes from the sample matrix may not be observed simply by using spike recovery. The relative standard deviations for the data included in the KCRV calculation in this key comparison were less than 7 % which was acceptable given the complexity of the matrix, the level of the analytes and the complexity of the analytical procedure. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual

  16. SIM.M.FF-S7: Final report on SIM/ANDIMET supplementary comparison for volume of liquids at 100 mL and 100 μL

    NASA Astrophysics Data System (ADS)

    Trujillo, S.; Maldonado, J. M.; Vega, M. C.; Santalla, E.; Sica, A.; Cantero, D.; Salazar, M.; Morales, A.; Solano, P.; Rodríguez, L. D.

    2016-01-01

    A SIM/ANDIMET comparison for liquid volume using two 100 mL pycnometers and two 100 μL piston pipettes was performed between January 2012 and October 2013. The National Metrology Institute (NMI) of Bolivia was the coordinating laboratory and the Mexican NMI provided technical assistance. The participating labs were IBMETRO (Bolivia), INM (Colombia), INEN (Ecuador), INDECOPI (Peru), LACOMET (Costa Rica), LATU (Uruguay), INTN (Paraguay), and CENAM (Mexico). Based on measurements made by CENAM at the beginning and end of the comparison, the transfer standards were stable during the comparison within 0.0001 mL for the 100 mL pycnometers and 0.03 μL for the 100 μL pipettes. For 100 mL, six of the eight participants agreed within ± 0.003 % and had standardized degrees of equivalence (EN) less than 1. Two participants (INEN and INM) had EN values greater than 1. For the 100 μL pipettes, the results were corrected for the influence of altitude and seven of the eight participants agreed within ± 0.3 %. Results from INEN and some from INM and IBMETRO had EN values greater than 1 for the 100 μL pipettes. Uncertainties recommended by Guideline DKD-R 8-1 for micropipettes were included. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. SUPPLEMENTARY COMPARISON: APMP.PR-S1 comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Xu, Gan; Huang, Xuebo; Liu, Yuanjie

    2007-01-01

    APMP.PR-S1, a supplementary comparison of irradiance responsivity of UVA detectors, was carried out among seven national metrology institutes piloted by SPRING Singapore from 2003 to 2005. Two quantities, the narrow band UV (365 nm ± 5 nm) irradiance responsivity and the broad band UVA (315 nm-400 nm) irradiance responsivity of the transfer detectors, have been compared. Commercial UV source (medium pressure mercury short arc lamp) and UVA detectors were used as transfer standards in the comparison. Measurement results from participants were reported and their uncertainties associated with the comparison were analysed in this report. The method of weighted mean with cut-off was used to calculate the comparison reference values. The results from most participating labs lie within ±5% against the comparison reference values with a few exceptions. The degree of agreement of the comparison depends not only on the base scales of spectral responsivity and spectral irradiance of a laboratory, but also equally importantly on the method used for the measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  18. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays.

    PubMed

    Burns, D T; Kessler, C; O'Brien, M; Minniti, R

    2012-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x-ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 10 3 , except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database.

  19. Final report of APMP.QM-S6: clenbuterol in porcine meat

    NASA Astrophysics Data System (ADS)

    Sin, D. W.-M.; Ho, C.; Yip, Y.-C.

    2016-01-01

    At the CCQM Organic Analysis Working Group (OAWG) Meeting held in April 2012 and the APMP TCQM Meeting held in November 2012, an APMP supplementary comparison (APMP.QM-S6) on the determination of clenbuterol in porcine meat was supported by the OAWG and APMP TCQM. This comparison was organized by the Government Laboratory, Hong Kong. In order to accommodate a wider participation, a pilot study (APMP.QM-P22) was run in parallel to APMP.QM-S6. This study provided the means for assessing the measurement capabilities for determination of low-polarity measurands in a procedure that requires extraction, clean-up, analytical separation, and selective detection in a food matrix. A total of 7 institutes registered for the supplementary comparison and 6 of them submitted their results. 4 results were included for SCRV calculation. All participating laboratories applied Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry (ID-LCMS/MS) technique with clenbuterol-d9 as internal standard spiked for quantitation in this programme. KEY WORDS FOR SEARCH APMP.QM-S6 and Clenbuterol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Final report on APMP.RF-S21.F

    NASA Astrophysics Data System (ADS)

    Ishii, Masanori; Kim, Jeong Hwan; Ji, Yu; Cho, Chi Hyun; Zhang, Tim

    2018-01-01

    The supplementary comparison report APMP.RF-S21.F describes the comparison of loop antennas, which was conducted between April 2013 and January 2014. The two comparison artefacts were well-characterised active loop antennas of diameter 30 cm and 60 cm respectively, which typically operate in a frequency range from 9 kHz to 30 MHz. These antennas represent the main groups of antennas which are used around the world for EMC measurements in the frequency range below 30 MHz. There are several well-known methods for calibrating the antenna factor of these devices. The calibration systems used in this comparison for the loop antennas employed the standard magnetic field method or the three-antenna method. Despite the limitations of the algorithm, which we used to derive the reference value for each case (particularly for small samples), the actual calculated reference values seem to be reasonable. As a result, the agreement between each participant was very good in all cases. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays

    PubMed Central

    Burns, D T; Kessler, C; O’Brien, M; Minniti, R

    2017-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x–ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 103, except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. PMID:28966399

  2. Final report on COOMET.EM-S11: Supplementary bilateral comparison of the measurement of current transformers between UNIIM and PTB

    NASA Astrophysics Data System (ADS)

    Mohns, Enrico; Sychev, Y.; Roeissle, G.

    2014-01-01

    A bilateral comparison of the measurement of current transformers was carried out between UNIIM (Russia) and PTB (Germany). For all of the current ratio error measurements and the phase displacement measurements there is a close agreement between PTB and UNIIM. Extensive measurements with the travelling standards were carried out at 18 different current ratios and at 5 different test points (1%, 5%, 20%, 100% and 120%) each. The range of tested primary currents was from 10 mA to 60 kA. It can therefore be concluded that the results of each laboratory agree very well within the calculated measurement uncertainties. No outliers were observed. Considering especially the En factors, the calculated uncertainties seem to be too conservative to some extent. Here there is the possibility to slightly improve the uncertainty budgets in the future if there is a need. The worst En factors are within ±0.6 at 1 kA/5 A and ±0.8 at 3 kA. The current comparator 'IW 32' from PTB may have caused that. This was subsequently confirmed. The primary current induced a small voltage in the compensation winding. This problem has now been solved. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. International comparison of activity measurements of a solution of 238Pu

    NASA Astrophysics Data System (ADS)

    Ratel, G.; Michotte, C.

    2018-01-01

    This report concerns an international comparison of measurements of a solution of 238Pu that was carried out by 12 participants in 2001. The report includes the degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on the supplementary comparison, EURAMET.M.P-S7 (EURAMET project 1040) in the pressure range from 1.10-4 Pa to 0.9 Pa

    NASA Astrophysics Data System (ADS)

    Wüthrich, C.; Alisic, S.; Bergoglio, M.; Saxholm, S.; Lefkopoulos, A.; Pražák, D.; Setina, J.

    2016-01-01

    Many laboratories within EURAMET started a calibration service in medium and high vacuum recently and did not have the opportunity to take part to a comparison before. In order to assess the uncertainty budget and the quality of the measurement of these laboratories, an intercomparison, EURAMET 1040 registered as EURAMET.M.P-S7, from 0.1 mPa to 0.9 Pa has been organised. The participants are the CMI (Czech republic), EIM (Greece), IMT (Slovenia), INRIM (Italy), IMBIH (Bosnia Herzegovinia) and MIKES (Finland) while METAS (Switzerland) is pilot laboratory. Three laboratories (INRIM, CMI and METAS) involved in this work have a primary definition of the pressure. Two spinning rotor gauges and a control electronic are used as transfer standard. The circulation of the transfer standard is organised as a succession of loops with a measurement by the pilot between each participant. A reference value has been determined based on a weighted mean of the results of the primary laboratories. All the participants have demonstrated their equivalence in the definition of the pressure. This comparison has been used as pilot comparison for the CCM.P-K14 project which covers the same scope with similar transfer standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Comparisons of absolute gravimeters (COOMET.M.G-S1)

    NASA Astrophysics Data System (ADS)

    Vinnichenko, Mr Alexander; Germak, Alessandro, Dr

    2017-01-01

    This report describes the results of the RMO supplementary comparison COOMET.M.G-S1 (also known as bilateral comparison COOMET 634/UA/14). The comparison measurements between the two participants NSC 'IM' (pilot laboratory) and INRIM were started in December 2015 and finished in January 2016. Participants of comparisons were conducted at their national standards the measurements of the free fall acceleration in gravimetric point laboratory of absolute gravimetry of INRIM named INRiM.2. Absolute measurements of gravimetric acceleration were conducted by ballistic gravimeters. The agreement between the two participants is good. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Comparison APMP.QM-S2.1: oxygen in nitrogen at atmospheric level

    NASA Astrophysics Data System (ADS)

    Kim, B. M.; Kim, K.; Jung, J.; Oh, S.; Hui, L.; Li, H.; Keat, T. B.; Ann, C. H.

    2016-01-01

    This document describes results of the bilateral comparison of an oxygen in nitrogen gas mixture. The nominal amount-of-substance fraction was 0.2 mol/mol oxygen in nitrogen Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on EURAMET.M.P-S12 — Bilateral supplementary comparison of the national pressure standards of CMI and INRIM in the range 300 Pa to 15 kPa of negative gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajícek, Zdenek; Bergoglio, Mercede; Pražák, Dominik; Pasqualin, Stefano

    2014-01-01

    This report describes a EURAMET bilateral supplementary comparison between Czech CMI and Italian INRIM in low negative gauge pressure in gas (nitrogen), denoted as EURAMET.M.P-S12. The digital non-rotating pressure balance FPG8601 manufactured by Fluke/DH-Instruments, USA is normally used for gauge and absolute pressures in the range from 1 Pa to 15 kPa, but with some modifications it can be used also for the negative gauge pressures in the same range. During the preparation of the visit of INRIM at CMI for the last comparison within the framework of EURAMET.M.P-K4.2010, it was agreed to also perform an additional comparison in the range from 300 Pa to 15 kPa of negative gauge pressure. The measurements were performed in October 2012. Both institutes successfully proved their equivalence in all the tested points in the range from 300 Pa to 15 kPa of negative gauge pressure in a comparison that had, so far, been unique. . Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Supplement to CCM.D-K4 'Hydrometer' report: linkage of EURAMET.M.D-K4 comparison, SIM.M.D-K4 comparison and the supplementary SIM.M.D-S2 to CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.

    2017-01-01

    Evaluation of different types of comparisons to a common set of reference values of a CIPM key comparison is essential to satisfy the concept of the CIPM Mutual Recognition Arrangement (CIPM MRA), where the DoEs of any participant who took part in comparisons should be within the Calibration and Measurement Capability (CMC) section of the CIPM MRA Key Comparison Data Base. The subject of this supplementary report is therefore to present the equivalence of each National Metrological Institute (NMI) participant in the CCM.D-K4 'Hydrometer' key comparison, which was performed in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20 °C, and the linkage of the European and Inter-American NMI results performed in the RMO.M.D-K4 comparisons as well as those of the supplementary SIM.M.D-S2 to the common set of KCRVs of the CCM.D-K4 'Hydrometer'. The linking procedure has been obtained by numerical simulation, based on the Monte Carlo method, in which the differences in the results of the different comparison between the intended laboratory and one or more linking laboratory/ies, which took part in both comparisons, are correlated with a continuous function describing the DoEs of the linking laboratory/ies with respect to the common set of KCRVs of the CCM.D-K4. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Supplementary comparison EURAMET.L-S24 on involute gear standards

    NASA Astrophysics Data System (ADS)

    Kniel, K.; Chanthawong, N.; Eastman, N.; Frazer, R.; Kupko, V.; Osawa, S.; Xue, Z.

    2014-01-01

    At its meeting in 2007, the EURAMET TC-Length decided to run an intercomparison of involute gear standards as a regional comparison with non-European involvement. The Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany (PTB) was identified as the pilot laboratory, responsible for planning, organizing and analyzing the comparison. In all, seven participants from China, Germany, Japan, Thailand, Ukraine, United Kingdom and USA were asked to measure three different gear standards specialized for profile, helix and pitch measurements. The measurements started mid 2008 and were finished at the end of 2010. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The comparison was registered as the supplementary comparison EURAMET.L-S24. The final report has been peer-reviewed and approved for publication by the CCL WG-MRA, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report on CCQM-K80: Comparison of value-assigned CRMs and PT materials: Creatinine in human serum

    NASA Astrophysics Data System (ADS)

    Camara, Johanna E.; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza

    2013-01-01

    regression was used to establish the key comparison reference function (KCRF) relating the assigned values to the repeatability measurements. Parametric bootstrap Monte Carlo was used to estimate 95% level-of-confidence coverage intervals for the degrees of equivalence of materials, d +/- U95(d), and of the participating NMIs, D +/- U95(D). Because of the wide range of creatinine mass fraction in the materials, these degrees of equivalence are expressed in percent relative form: %d +/- U95(%d) and %D +/- U95(%D). On the basis of leave-one-out cross-validation, the assigned values for 16 of the 17 materials were deemed equivalent at the 95% level of confidence. These materials were used to define the KCRF. The excluded material was identified as having a marginally underestimated assigned uncertainty, giving it large and potentially anomalous influence on the KCRF. However, this material's %d of 1.4 +/- 1.5 indicates that it is equivalent with the other materials at the 95% level of confidence. The median |%d| for all 17 of the materials is 0.3 with a median U95(%d) of 1.9. All of these higher-order CRMs for creatinine in human serum are equivalent within their assigned uncertainties. The median |%D| for the participating NMIs is 0.3 with a median U95(%D) of 2.1. These results demonstrate that all participating NMIs have the ability to correctly value-assign CRMs and proficiency test materials for creatinine in human serum and similar measurands. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Quantum key distribution with finite resources: Secret key rates via Renyi entropies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abruzzo, Silvestre; Kampermann, Hermann; Mertz, Markus

    A realistic quantum key distribution (QKD) protocol necessarily deals with finite resources, such as the number of signals exchanged by the two parties. We derive a bound on the secret key rate which is expressed as an optimization problem over Renyi entropies. Under the assumption of collective attacks by an eavesdropper, a computable estimate of our bound for the six-state protocol is provided. This bound leads to improved key rates in comparison to previous results.

  13. SUPPLEMENTARY COMPARISON Bilateral comparison on the calibrations of hydrometers for liquid density between INRIM-Italy and INMETRO-Brazil: SIM.M.D-S2

    NASA Astrophysics Data System (ADS)

    Lorefice, Salvatore; Malta, Dalni; Julio Pinheiro, José; Marteleto, Paulo Roberto

    2010-01-01

    The results of the SIM.M.D-S2 bilateral comparison between INRIM-Italy and INMETRO-Brazil are summarized in this report. The aims of this comparison were to check the stated uncertainty levels and the degrees of equivalence between the two institutes on the calibration of hydrometers for liquid density in the range of 800 kg m-3 to 1000 kg m-3 at 20 ºC, by means of two transfer standards of excellent metrological characteristics. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Transportation: The Key to Unlocking the Final Frontier

    NASA Technical Reports Server (NTRS)

    Sackheim, Robert L.; Saucier, Sidney (Technical Monitor)

    2000-01-01

    For this future generations in this new millennium, only two new frontiers remain to be explored and developed by humans: Under the oceans, seas and lakes (about 80 percent of the Earth) and The vast reaches of near and outer space. We are slowly running out of resources while this planet's population is exploding. We must establish new, highly reliable and low-cost ways to colonize under the seas and to get people permanently off "Spaceship Planet Earth". We must establish new colonies permanently in space because it is vital to the ultimate survival of the human race. Reliable and affordable space transportation for routine human travel into space and the planets is once again the key to developing this last great frontier. This talk will now focus on what NASA is now doing to initiate the process in earnest. Space transportation is the key, and once again will only meet the needs with new generations of competent, talented, and innovative mechanical engineers.

  15. Final report on supplementary comparison APMP.M.P-S6 in gas gauge pressure from 10 MPa to 100 MPa

    NASA Astrophysics Data System (ADS)

    Kajikawa, Hiroaki; Olson, Douglas A.; Iizumi, Hideaki; Driver, Robert Greg; Kojima, Momoko

    2016-01-01

    A supplementary comparison of gas high-pressure standards was conducted between the National Metrology Institute of Japan (NMIJ/AIST) and the National Institute of Standards and Technology (NIST), within the framework of the Asia-Pacific Metrology Programme (APMP), in order to determine their degrees of equivalence in the pressure range from 10 MPa to 100 MPa in gauge mode. The pilot institute was NMIJ/AIST. The measurements were carried out from July 2014 to October 2014. Both participating institutes used pressure balances as their pressure standards. Different gases were used for the pressure medium: NMIJ/AIST used Nitrogen, while NIST used Helium. A set of two pressure monitors was used as the transfer standard. The pressure monitors were found sufficiently stable during the measurements. Characteristics of the pressure monitors were evaluated at the pilot institute, and then used for data corrections and uncertainty estimations. In particular, the effect of the gas medium on the pressure monitors was found to be significant, and then all the measurement data were corrected to those with Nitrogen. The degrees of equivalence between the two institutes were evaluated by the relative differences of the participant's results and their associated expanded (k = 2) uncertainties. The gas pressure standards in the range 10 MPa to 100 MPa for gauge mode of the two participating institutes were found to be equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Comparison of measurement standards of the acoustic pressure in air in the low frequency range: COOMET.AUV.A-K2

    NASA Astrophysics Data System (ADS)

    Chalyy, V.

    2011-01-01

    A bilateral regional comparison of national microphone standards from 2 Hz to 250 Hz was carried out between the DP NDI 'Systema' (Ukraine) and the VNIIFTRI (Russia) from July to September 2009. The comparison, COOMET.AUV.A-K2, was based on the pressure calibration of laboratory standard microphones type LSIP. The comparison results have been linked to the established key comparison reference value (KCRV) of CCAUV.A-K2. The degrees of equivalence, expressed as the deviation from the established KCRV and its expanded uncertainty (k = 2), have been determined, and the comparison result is in agreement with the KCRV within the estimated uncertainties at all employed frequencies. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Comparison between hadronic final states produced in μ p and e + e - interactions

    NASA Astrophysics Data System (ADS)

    Arneodo, M.; Arvidson, A.; Aubert, J. J.; Badelek, B.; Beaufays, J.; Bee, C. P.; Benchouk, C.; Berghoff, G.; Bird, I.; Blum, D.; Böhm, E.; de Bouard, X.; Brasse, F. W.; Braun, H.; Broll, C.; Brown, S.; Brück, H.; Calen, H.; Chima, J. S.; Ciborowski, J.; Clifft, R.; Coignet, G.; Combley, F.; Coughlan, J.; D'Agostini, G.; Dahlgren, S.; Dengler, F.; Derado, I.; Dreyer, T.; Drees, J.; Düren, M.; Eckardt, V.; Edwards, A.; Edwards, M.; Ernst, T.; Eszes, G.; Favier, J.; Ferrero, M. I.; Figiel, J.; Flauger, W.; Foster, J.; Gabathuler, E.; Gajewski, J.; Gamet, R.; Gayler, J.; Geddes, N.; Grafström, P.; Grard, F.; Haas, J.; Hagberg, E.; Hasert, F. J.; Hayman, P.; Heusse, P.; Jaffré, M.; Jacholkowska, A.; Janata, F.; Jancso, G.; Johnson, A. S.; Kabuss, E. M.; Kellner, G.; Korbel, V.; Krüger, J.; Kullander, S.; Landgraf, U.; Lanske, D.; Loken, J.; Long, K.; Maire, M.; Malecki, P.; Manz, A.; Maselli, S.; Mohr, W.; Montanet, F.; Montgomery, H. E.; Nagy, E.; Nassalski, J.; Norton, P. R.; Oakham, F. G.; Osborne, A. M.; Pascaud, C.; Pawlik, B.; Payre, P.; Peroni, C.; Peschel, H.; Pessard, H.; Pettingale, J.; Pietrzyk, B.; Pönsgen, B.; Pötsch, M.; Renton, P.; Ribarics, P.; Rith, K.; Rondio, E.; Sandacz, A.; Scheer, M.; Schlagböhmer, A.; Schiemann, H.; Schmitz, N.; Schneegans, M.; Scholz, M.; Schröder, T.; Schouten, M.; Schultze, K.; Sloan, T.; Stier, H. E.; Studt, M.; Taylor, G. N.; Thénard, J. M.; Thompson, J. C.; de La Torre, A.; Toth, J.; Urban, L.; Wallucks, W.; Whalley, M.; Wheeler, S.; Williams, W. S. C.; Wimpenny, S. J.; Windmolders, R.; Wolf, G.

    1987-12-01

    A comparison is made between the properties of the final state hadrons produced in 280 GeV μ p interactions and in e + e - annihilation. The Lund model of hadroproduction is used as an aid in understanding the differences observed. The hadron distributions from μ p and e + e - interactions are consistent with the quark parton model assumption of environmental independence, provided that the differences in heavy quark production and hard QCD effects in the two processes are taken into account. A comparison with a K + p experiment is also made. Values are also determined for the Lund model parameters σq = 0.410 ± 0.002 ± 0.020 GeV and σ' = 0.29{-0.15/-0.13 +0.09+0.10} GeV, controlling the transverse momenta in fragmentation and intrinsic transverse momenta of the struck quark respectively.

  18. SUPPLEMENTARY COMPARISON: Report of the bilateral comparison of the calibrations of hydrometers for liquid density determination between CENAM-Mexico and INRIM-Italy: SIM.M.D-S1

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Lorefice, Salvatore

    2009-01-01

    Hydrometers are instruments usually made of glass which are widely used for different levels of precision to measure liquid density and related quantities to control different products and processes. This bilateral comparison on the calibration of hydrometers shows that results reported by CENAM-Mexico and INRIM-Italy are consistent within the claimed uncertainty in the range of 800 kg/m3 to 1200 kg/m3. This bilateral comparison is intended to link the two regional comparisons SIM.M.D-K4 and EURAMET.D-K4. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Comparison on the calibrations of hydrometers for liquids density determination between SIM laboratories

    NASA Astrophysics Data System (ADS)

    Morales, Abed; Quiroga, Aldo; Daued, Arturo; Cantero, Diana; Sequeira, Francisco; Castro, Luis Carlos; Becerra, Luis Omar; Salazar, Manuel; Vega, Maria

    2017-01-01

    A supplementary comparison was made between SIM laboratories concerning the calibration of four hydrometers within the range of 600 kg/m3 to 2000 kg/m3. The main objectives of the comparison were to evaluate the degree of equivalences SIM NMIs in the calibration of hydrometers of high accuracy. The participant NMIs were: CENAM, IBMETRO, INEN, INDECOPI, INM, INTN and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Characteristics of precision 1 Ω standard resistors influencing transport behaviour and the uncertainty of key comparisons

    NASA Astrophysics Data System (ADS)

    Jones, G. R.; Pritchard, B. J.; Elmquist, R. E.

    2009-10-01

    National measurement institutes (NMIs) participate in international key comparisons organized by the Bureau International des Poids et Mesures (BIPM), the Regional Metrology Organizations (RMOs) or the Consultative Committees of the Comité International des Poids et Mesures (CIPM) in order to provide evidence of equivalent reference standards and measurement capabilities. The US National Institute of Standards and Technology (NIST) and the National Measurement Institute of Australia (NMIA) have recently examined power loading and several other influences on the value of precision transportable 1 Ω resistors that can increase the uncertainty of key comparisons. We have studied the effects of temperature, barometric pressure, humidity, power loading and heat dissipation in oil on transportable wire-wound 1 Ω resistance standards that are based on different alloys and construction principles. This work focuses on standards manufactured from 1970 through 2000 by the NMIA made of Evanohm alloy and on Thomas-type resistors designed in the 1930s and made of Manganin alloy. We show that the relative standard uncertainty related to transport can be less than 0.01 μΩ Ω-1 when using certain resistors of these two types that are characterized and selected for stability. We describe the characterization process, and relate the environmental influences to the physical design, as well as to the mechanical properties and condition of the standards.

  1. Final report on COOMET.QM-S1 (COOMET project no 483/RU/09): Supplementary comparison of primary standard gas mixtures: Nitrogen monoxide in nitrogen (50 µmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Shor, N. B.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Kozia, V. G.; Shpilnyi, S. A.; Petryshyn, P. V.; Iakubov, S. E.; Kluchits, A. S.; Ananyin, V. N.; Mironchik, A. M.; Mokhnach, M. V.; Valkova, M.; Stovcik, V.; Walden, J.; Augusto, C. R.; Fioravante, A. L.; Ribeiro, C. C.; Sobrinho, D. C. G.; Oudwater, R. J.; da Cunha, V. S.

    2014-01-01

    Nitrogen monoxide is one of the main contaminants present in the atmospheric air due to emissions of vehicles and power stations. Taking into account the positive experience of VNIIM in the pilot study CCQM-P73 (Nitrogen monoxide gas standards, 30 µmol/mol to 70 µmol/mol), a COOMET project (No 483/RU/09) on the subject was decided and registered in the KCDB as supplementary comparison COOMET.QM-S1. This involved six National Metrology Institutes, aiming to consolidate or support their Calibration and Measurement Capabilities in this field. It was found that most of the results were consistent with the reference (gravimetric) values, with observed differences not exceeding ±1.3% and not exceeding either the appropriate assigned expanded uncertainties. There was, however, one exception: the INMETRO difference from the reference value is slightly higher than the expended uncertainty. The mixtures prepared for this exercise were found to be stable during about one year within the uncertainty of the measurements. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by COOMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. SUPPLEMENTARY COMPARISON: APMP.EM-S6: Bilateral supplementary comparison of resistance

    NASA Astrophysics Data System (ADS)

    Charoensook, Ajchara; Jassadajin, Chaiwat; Chen, Henry; Ricketts, Brian

    2004-01-01

    A bilateral supplementary comparison of resistance, APMP.EM-S6, was conducted between the National Institute of Metrology Thailand (NIMT) and the CSIRO National Measurement Laboratory of Australia (NML). The comparison covered seven values of resistance, 0.1 Ω, 1 Ω, 100 Ω, 10 kΩ, 100 kΩ, 1 MΩ and 100 MΩ. The 0.1 Ω resistor was a YEW type 2792, the 100 MΩ resistor was an IET type SRC and the other five resistors were Fluke type 742A. The resistors were supplied by NIMT, and NML was the pilot laboratory for the comparison. The measurements for the comparison were made between December 2003 and April 2004. The resistors were measured on three separate occasions by NIMT and between each of these occasions the resistors were sent to NML for measurement. The resistors of nominal values 0.1 Ω, 1 Ω, 100 Ω and 10 kΩ were measured as four-terminal resistors while the 100 kΩ, 1 MΩ and 100 MΩ resistors were measured as two-terminal resistors. The quantity En (the absolute value of the difference between the values obtained at the two laboratories divided by the root sum square of the expanded uncertainties of the two values) was calculated for each resistance value used in the comparison. In all cases En was less than 0.5. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the Mutual Recognition Arrangement (MRA).

  3. Results of the EURAMET.RI(II)-S6.I-129 supplementary comparison

    NASA Astrophysics Data System (ADS)

    García-Toraño, Eduardo; Altzitzoglou, Timotheos; Auerbach, Pavel; Bé, Marie-Martine; Lourenço, Valérie; Bobin, Christophe; Cassette, Philippe; Dersch, Rainer; Kossert, Karsten; Nähle, Ole; Peyrés, Virginia; Pommé, Stefaan; Rozkov, Andrej; Sanchez-Cabezudo, Anabel; Sochoro&vacute; , Jana

    2015-01-01

    An international comparison of the long-lived gamma-ray emitter 129I has been recently completed. A total of 5 laboratories measured a solution prepared by Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT). Aliquots of the master solution were standardized in terms of activity per mass unit by participant laboratories using 4 different techniques. The results of the comparison can be used as the basis for establishing the equivalence among the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Public-key quantum digital signature scheme with one-time pad private-key

    NASA Astrophysics Data System (ADS)

    Chen, Feng-Lin; Liu, Wan-Fang; Chen, Su-Gen; Wang, Zhi-Hua

    2018-01-01

    A quantum digital signature scheme is firstly proposed based on public-key quantum cryptosystem. In the scheme, the verification public-key is derived from the signer's identity information (such as e-mail) on the foundation of identity-based encryption, and the signature private-key is generated by one-time pad (OTP) protocol. The public-key and private-key pair belongs to classical bits, but the signature cipher belongs to quantum qubits. After the signer announces the public-key and generates the final quantum signature, each verifier can verify publicly whether the signature is valid or not with the public-key and quantum digital digest. Analysis results show that the proposed scheme satisfies non-repudiation and unforgeability. Information-theoretic security of the scheme is ensured by quantum indistinguishability mechanics and OTP protocol. Based on the public-key cryptosystem, the proposed scheme is easier to be realized compared with other quantum signature schemes under current technical conditions.

  5. APMP comparison on luminous flux units (APMP.PR-K4)

    NASA Astrophysics Data System (ADS)

    Liu, H.; Lin, Y. D.; Yang, C. Z.; Yu, J.

    2018-01-01

    During the 18th APMP meeting in 2004, TCPR agreed that the luminous flux should be one of the several regional comparisons to be conducted in the field of photometry and radiometry, and the project was named as APMP.PR-K4. Nine laboratories took part in this comparison. A group of LF 200W lamps (no less than three) was used as transfer artifacts by each participant. The National Institute of Metrology (NIM, China) acted as the pilot laboratory. Presented in this report are the detailed procedures and results of the work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final report on AFRIMETS.QM-K27: Determination of ethanol in aqueous matrix

    NASA Astrophysics Data System (ADS)

    Archer, Marcellé; Fernandes-Whaley, Maria; Visser, Ria; de Vos, Jayne; Prins, Sara; Rosso, Adriana; Ruiz de Arechavaleta, Mariana; Tahoun, Ibrahim; Kakoulides, Elias; Luvonga, Caleb; Muriira, Geoffrey; Naujalis, Evaldas; Zakaria, Osman Bin; Buzoianu, Mirella; Bebic, Jelena; Achour Mounir, Ben; Thanh, Ngo Huy

    2013-01-01

    Level 1; four of the ten participating laboratories submitted mean results within 1.5% of the gravimetric reference value for Level 2. Two of the participating laboratories achieved mean results within 1.5% of the gravimetric reference value for both levels. Participants in the AFRIMETS-K27 study would therefore have benefited from a pilot study in which to test their measurement capability prior to participation in the key comparison. Several NMIs, however, will still be able to make new CMC claims based on their performance in this comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Evaluation of a KeyStone/Tensar geogrid retaining wall system : final report.

    DOT National Transportation Integrated Search

    1992-01-01

    The KeyStone/Tensar Geogrid retaining wall system is an alternative to conventional reinforced concrete retaining wall structures. KeyStone concrete wall units, Tensar geogrid, and compacted soils are combined to form a reinforced soil mass that toge...

  8. Final report on APMP.QM-S5: Essential and toxic elements in seafood

    NASA Astrophysics Data System (ADS)

    Valiente, Liliana; Bennett, John W.; Caciano de Sena, Rodrigo; Kotzeva, Boriana; Massiff, Gabriela; Chao, Jingbo; Wang, Jun; Nasr, Randa; Labarraque, Guillaume; Kakoulidis, Elias; Lampi, Eugenia; Wai-mei Sin, Della; Mok, Chuen-shing; Wong, Siu-kay; Yip, Yiu-chung; Gopala Aggarwal, Shankar; Gupta, Prabhat K.; Zhu, Yanbei; Miyashita, Shin-ichi; Yim, Yong-Hyeon; Zakaria, Osman; Manzano, Judith Velina Lara; Shin, Richard; Horvat, Milena; Yafa, Charun

    2013-01-01

    participants. For this supplementary comparison, inorganic core capabilities have been demonstrated by concerned participants with respect to methods including ICP-MS (without isotope dilution), ID-ICP-MS, ICP-OES, INAA and AAS on the determination of total arsenic, cadmium, iron and zinc in a matrix of seafood. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Secret Key Crypto Implementations

    NASA Astrophysics Data System (ADS)

    Bertoni, Guido Marco; Melzani, Filippo

    This chapter presents the algorithm selected in 2001 as the Advanced Encryption Standard. This algorithm is the base for implementing security and privacy based on symmetric key solutions in almost all new applications. Secret key algorithms are used in combination with modes of operation to provide different security properties. The most used modes of operation are presented in this chapter. Finally an overview of the different techniques of software and hardware implementations is given.

  10. International comparison CCQM-K119 liquefied petroleum gas

    NASA Astrophysics Data System (ADS)

    Brewer, P. J.; Downey, M. L.; Atkins, E.; Brown, R. J. C.; Brown, A. S.; Zalewska, E. T.; van der Veen, A. M. H.; Smeulders, D. E.; McCallum, J. B.; Satumba, R. T.; Kim, Y. D.; Kang, N.; Bae, H. K.; Woo, J. C.; Konopelko, L. A.; Popova, T. A.; Meshkov, A. V.; Efremova, O. V.; Kustikov, Y.

    2018-01-01

    Liquefied hydrocarbon mixtures with traceable composition are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas), thus meeting the needs of an increasingly large industrial market. This comparison aims to assess the analytical capabilities of laboratories for measuring the composition of a Liquid Petroleum Gas (LPG) mixture when sampled in the liquid phase from a Constant Pressure Cylinder. Mixtures contained ethane, propane, propene, i-butane, n-butane, but-1-ene and i-pentane with nominal amount fractions of 2, 71, 9, 4, 10, 3 and 1 cmol mol-1 respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. SUPPLEMENTARY COMPARISON: EUROMET.L-S10 Comparison of squareness measurements

    NASA Astrophysics Data System (ADS)

    Mokros, Jiri

    2005-01-01

    from the weighted mean of data from participating laboratories, while some of them were excluded on the basis of statistical evaluation. Graphical interpretations of all deviations are contained in the Final Report. In order to compare the individual deviations mutually (25 profiles for the granite square and 44 profiles for the cylinder), graphical illustrations of 'standard deviations' and both extreme values (max. and min.) of deviations were created. This regional supplementary comparison has provided independent information about the metrological properties of the measuring equipment and method used by the participating NMIs. The Final Report does not contain the En values. Participants could not estimate some contributions in the uncertainty budget on the basis of previous comparisons, since no comparison of this kind had ever been organized. Therefore the En value cannot reflect the actual state of the given NMI. Instead of En, an analysis has been performed by means of the Grubbs test according to ISO 5725-2. This comparison provided information about the state of provision of metrological services in the field of big squares measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EUROMET, according to the provisions of the Mutual Recognition Arrangement (MRA).

  12. Final report on APMP.M.P-S4: Results of the bilateral supplementary comparison on pressure measurements in the range (60 to 350) kPa of gauge pressure in gas media

    NASA Astrophysics Data System (ADS)

    Priruenrom, T.; Sabuga, W.; Konczak, T.

    2013-01-01

    The bilateral supplementary comparison APMP.M.P-S4 on pressure measurements in the range (60 to 350) kPa of gauge pressure in gas media was organized by National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison is to check equivalence of gas pressure standards between NIMT and PTB. The period of measurement covered November to December 2012. NIMT provided a transfer standard, which was a WC-WC piston-cylinder assembly (PCA) with a nominal effective area of 10 cm2 manufactured by Fluke Corporation, DHI. The measurements were performed at pressures (60, 100, 150, 200, 250, 300 and 350) kPa. The NIMT laboratory standard used was a pressure balance with a PCA of 10 cm2 manufactured by DHI and identified by serial number 0693. The PTB laboratory standard used was a pressure balance with a PCA of 10 cm2 manufactured by Desgranges et Huot (DH) and identified by serial number 288. The results of this comparison show that the relative difference of the effective area values obtained by NIMT and PTB is not larger than 4.3 ppm, which corresponds to En = 0.26. Therefore, it confirms that the gas pressure standards maintained by the two institutes, NIMT and PTB, in the pressure range (60 to 350) kPa in gauge mode are equivalent under their uncertainties claimed. The result of this comparison is essential to support the calibration and measurement capabilities (CMC) of NIMT in this pressure range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. AC Power at Power Frequencies: Bilateral comparison between SASO NMCC and TÜBİTAK UME

    NASA Astrophysics Data System (ADS)

    Çaycı, Hüseyin; Yılmaz, Özlem; AlRobaish, Abdullah M.; AlAnazi, Shafi S.; AlAyali, Ahmed R.; AlRumie, Rashed A.

    2018-01-01

    A supplementary bilateral comparison measurement on AC Power at 50/60 Hz between SASO NMCC (GULFMET) and TÜBİTAK UME (EURAMET) was performed with the primary power standards of each partner. Measurement methods and setups which are very similar of the participants, measurement results, calculation of differences in the results, evaluation of uncertainties are given within this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Continuous variable quantum key distribution: finite-key analysis of composable security against coherent attacks.

    PubMed

    Furrer, F; Franz, T; Berta, M; Leverrier, A; Scholz, V B; Tomamichel, M; Werner, R F

    2012-09-07

    We provide a security analysis for continuous variable quantum key distribution protocols based on the transmission of two-mode squeezed vacuum states measured via homodyne detection. We employ a version of the entropic uncertainty relation for smooth entropies to give a lower bound on the number of secret bits which can be extracted from a finite number of runs of the protocol. This bound is valid under general coherent attacks, and gives rise to keys which are composably secure. For comparison, we also give a lower bound valid under the assumption of collective attacks. For both scenarios, we find positive key rates using experimental parameters reachable today.

  15. SUPPLEMENTARY COMPARISON COOMET. M.P-S5 of hydraulic gauge pressure standards from 5 MPa to 34 MPa

    NASA Astrophysics Data System (ADS)

    Babayev, E. A.; Klenovská, Simona; Páviš, Richard; Pražák, Dominik

    2018-01-01

    This report describes the results of bilateral inter laboratory comparison (BILC) denoted as COOMET.M.P-S5 (also known as supplementary comparison COOMET 723/AZ/17). The comparison measurements between the two participants, Czech Metrology Institute (CMI) (pilot laboratory) and Azerbaijan İnstitute of Metrology (AzMI), started in April 2017 and finished in June 2017. The transfer standards was a digital manometer, Crystal XP 2i with the gauge pressure range (0–34000) kPa. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Activity measurements of the radionuclide 124Sb by the LNE-LNHB, France for the ongoing comparison BIPM.RI(II)-K1.Sb-124

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Ratel, G.; Moune, M.; Bobin, C.

    2011-01-01

    In 2007, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of 124Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Key Competencies. Second Edition.

    ERIC Educational Resources Information Center

    Haworth, David; Browne, Geoff

    Key competencies (or generic skills) have been specified in four sources: Further Education Unit (FEU), United Kingdom (1987); Finn Report (1991) and Mayer Committee (1992), Australia; U.S. Labor Secretary's Commission on Achieving Necessary Skills (SCANS) (June 1991); and Butterworth and Lovell (1983), New South Wales. A comparison of the four…

  18. Final report on CCQM-P151: Halocarbons in dry whole air

    NASA Astrophysics Data System (ADS)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Seog Kim, Jin; Hall, Bradley; Weiss, Ray; Harth, Christina; Reimann, Stefan; Vollmer, Martin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a pilot study between National Metrology Institutes and atmospheric research laboratories for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2-trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.

  19. Image encryption using fingerprint as key based on phase retrieval algorithm and public key cryptography

    NASA Astrophysics Data System (ADS)

    Zhao, Tieyu; Ran, Qiwen; Yuan, Lin; Chi, Yingying; Ma, Jing

    2015-09-01

    In this paper, a novel image encryption system with fingerprint used as a secret key is proposed based on the phase retrieval algorithm and RSA public key algorithm. In the system, the encryption keys include the fingerprint and the public key of RSA algorithm, while the decryption keys are the fingerprint and the private key of RSA algorithm. If the users share the fingerprint, then the system will meet the basic agreement of asymmetric cryptography. The system is also applicable for the information authentication. The fingerprint as secret key is used in both the encryption and decryption processes so that the receiver can identify the authenticity of the ciphertext by using the fingerprint in decryption process. Finally, the simulation results show the validity of the encryption scheme and the high robustness against attacks based on the phase retrieval technique.

  20. Supplementary comparison of 500 microgram, 200 microgram, 100 microgram and 50 microgram weights—EURAMET.M.M-S9

    NASA Astrophysics Data System (ADS)

    Davidson, Stuart; Valcu, Adriana; Medina, Nieves; Zuda, Jaroslav; Snopko, Laurenc; Kolozinska, Irena

    2017-01-01

    A comparison of sub-milligram mass standards was undertaken within EURAMET between NPL (as the pilot laboratory), INM (Romania), CEM (Spain), CMI (Czech Republic), SMU (Slovakia) and NSC IM (Ukraine). The weights circulated had nominal values of 500 micrograms, 200 micrograms (2 weights), 100 micrograms and 50 micrograms. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Cosmology Without Finality

    NASA Astrophysics Data System (ADS)

    Mahootian, F.

    2009-12-01

    The rapid convergence of advancing sensor technology, computational power, and knowledge discovery techniques over the past decade has brought unprecedented volumes of astronomical data together with unprecedented capabilities of data assimilation and analysis. A key result is that a new, data-driven "observational-inductive'' framework for scientific inquiry is taking shape and proving viable. The anticipated rise in data flow and processing power will have profound effects, e.g., confirmations and disconfirmations of existing theoretical claims both for and against the big bang model. But beyond enabling new discoveries can new data-driven frameworks of scientific inquiry reshape the epistemic ideals of science? The history of physics offers a comparison. The Bohr-Einstein debate over the "completeness'' of quantum mechanics centered on a question of ideals: what counts as science? We briefly examine lessons from that episode and pose questions about their applicability to cosmology. If the history of 20th century physics is any indication, the abandonment of absolutes (e.g., space, time, simultaneity, continuity, determinacy) can produce fundamental changes in understanding. The classical ideal of science, operative in both physics and cosmology, descends from the European Enlightenment. This ideal has for over 200 years guided science to seek the ultimate order of nature, to pursue the absolute theory, the "theory of everything.'' But now that we have new models of scientific inquiry powered by new technologies and driven more by data than by theory, it is time, finally, to relinquish dreams of a "final'' theory.

  2. Infrared spectral normal emittance/emissivity comparison

    NASA Astrophysics Data System (ADS)

    Hanssen, L.; Wilthan, B.; Filtz, J.-R.; Hameury, J.; Girard, F.; Battuello, M.; Ishii, J.; Hollandt, J.; Monte, C.

    2016-01-01

    The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized Inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report on CCQM-K27.2: Second Subsequent study: determination of ethanol in aqueous media

    NASA Astrophysics Data System (ADS)

    Schantz, Michele M.; Parris, Reenie M.; May, Willie E.; Rosso, Adriana; Puglisi, Celia; Marques Rodrigues Caixeiro, Janaína; Massiff, Gabriela; Camacho Frías, Evangelina; Pérez Urquiza, Melina; Archer, Marcellé; Visser, M. S.; deVos, Betty-Jayne

    2013-01-01

    subsequent study (nominal concentrations of 0.2 mg/g, 1 mg/g, 3 mg/g and 60 mg/g). The three participants in the CCQM-K27-Subsequent key comparison demonstrated their ability to measure ethanol in aqueous matrix in the concentration range of 0.2 mg/g to 60 mg/g. A report on this project has been approved by the CCQM and can be found at the BIPM website. A second follow-on key comparison, CCQM-K27.2 Second Subsequent, was initiated in 2006 to accommodate laboratories that had not been ready to benchmark their methods in the previous two CCQM-K27 studies. Two levels of ethanol in water were used in the second subsequent study ranging in concentration between 0.5 mg/g and 4 mg/g. Four of the five participants in the CCQM-K27.2 Second Subsequent key comparison demonstrated their ability to measure ethanol in aqueous matrix in that concentration range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -25 °C TO +20 °C.

    PubMed

    Meyer, C W; Hill, K D

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC.

  5. Physical Unclonable Function Hardware Keys Utilizing Kirchhoff-Law Secure Key Exchange and Noise-Based Logic

    NASA Astrophysics Data System (ADS)

    Kish, Laszlo B.; Kwan, Chiman

    Weak unclonable function (PUF) encryption key means that the manufacturer of the hardware can clone the key but not anybody else. Strong unclonable function (PUF) encryption key means that even the manufacturer of the hardware is unable to clone the key. In this paper, first we introduce an "ultra" strong PUF with intrinsic dynamical randomness, which is not only unclonable but also gets renewed to an independent key (with fresh randomness) during each use via the unconditionally secure key exchange. The solution utilizes the Kirchhoff-law-Johnson-noise (KLJN) method for dynamical key renewal and a one-time-pad secure key for the challenge/response process. The secure key is stored in a flash memory on the chip to provide tamper-resistance and nonvolatile storage with zero power requirements in standby mode. Simplified PUF keys are shown: a strong PUF utilizing KLJN protocol during the first run and noise-based logic (NBL) hyperspace vector string verification method for the challenge/response during the rest of its life or until it is re-initialized. Finally, the simplest PUF utilizes NBL without KLJN thus it can be cloned by the manufacturer but not by anybody else.

  6. Force supplementary comparison at SIM (SIM.M.F-S5), compression testing machines calibration, up to 200 kN

    NASA Astrophysics Data System (ADS)

    Cárdenas Moctezuma, A.; Torres Guzmán, J. C.

    2016-01-01

    CENAM, through the Force and Pressure Division, organized a comparison on testing machines calibration, in compression mode. The participating laboratories were SIM National Institutes of Metrology from Colombia, Peru and Costa Rica, where CENAM, Mexico was the pilot and reference laboratory. The results obtained by the laboratories are presented in this paper as well as the analysis of compatibility. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. APMP supplementary comparison (APMP.L-S8) measurement of flatness of optical flat by interferometry

    NASA Astrophysics Data System (ADS)

    Buajarern, J.; Bitou, Y.; Zi, X.; Zhao, L.; Swift, N.; Agarwal, A.; Hungwe, F.

    2018-01-01

    A reginal supplementary comparison, APMP.L-S8, was started in 2015 to demonstrate the equivalence of routine calibration services offered by NMIs to clients. Participants in this APMP.L-S8 comparison agreed to apply interferometric method for flatness measurement of the optical flats. There are two configurations of flatness interferometer used in this comparison, vertical type and horizontal type. There are seven laboratories from NMIs participated this supplementary comparison which included NIMT, NMIJ, NIM, NMC/A*STAR, MSL, NPLI and NMISA. This report describes the measurement results of two optical flats, diameter of 70 mm and 160 mm. The calibrations of this comparison were carried out by participants during the period from July 2015 to September 2016. The results show that there is a degree of equivalence below 1 for all measurands. Hence, there is a close agreement between the measurements from all participants. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. ClinicalKey: a point-of-care search engine.

    PubMed

    Vardell, Emily

    2013-01-01

    ClinicalKey is a new point-of-care resource for health care professionals. Through controlled vocabulary, ClinicalKey offers a cross section of resources on diseases and procedures, from journals to e-books and practice guidelines to patient education. A sample search was conducted to demonstrate the features of the database, and a comparison with similar tools is presented.

  9. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −25 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Hill, K.D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952

  10. Comparison of density determination of liquid samples by density meters

    NASA Astrophysics Data System (ADS)

    Buchner, C.; Wolf, H.; Vámossy, C.; Lorefice, S.; Lenard, E.; Spohr, I.; Mares, G.; Perkin, M.; Parlic-Risovic, T.; Grue, L.-L.; Tammik, K.; van Andel, I.; Zelenka, Z.

    2016-01-01

    Hydrostatic density determinations of liquids as reference material are mainly performed by National Metrology Institutes to provide means for calibrating or checking liquid density measuring instruments such as oscillation-type density meters. These density meters are used by most of the metrology institutes for their calibration and scientific work. The aim of this project was to compare the results of the liquid density determination by oscillating density meters of the participating laboratories. The results were linked to CCM.D.K-2 partly via Project EURAMET.M.D.K-2 (1019) "Comparison of liquid density standards" by hydrostatic weighing piloted by BEV in 2008. In this comparison pentadecane, water and of oil with a high viscosity were measured at atmospheric pressure using oscillation type density meter. The temperature range was from 15 °C to 40 °C. The measurement results were in some cases discrepant. Further studies, comparisons are essential to explore the capability and uncertainty of the density meters Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    PubMed

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  12. Bilateral comparison on the calibration of a set of F1 mass standards between IBMETRO (Bolivia) and INTI (Argentina)

    NASA Astrophysics Data System (ADS)

    Quille, Ruben; Sanchez, Jorge; Escalante, Boris

    2017-01-01

    Mass calibration is an important activity for National Metrology Institutes (NMIs), due to the amount of measurements on scientific, industrial and legal activities that have traceability to the national mass standards of each country. In order to evaluate the stated uncertainty and degree of equivalence between INTI-Argentina and IBMETRO-Bolivia on mass calibration a bilateral comparison was agreed between both laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  14. Differential phase-shift keying and channel equalization in free space optical communication system

    NASA Astrophysics Data System (ADS)

    Zhang, Dai; Hao, Shiqi; Zhao, Qingsong; Wan, Xiongfeng; Xu, Chenlu

    2018-01-01

    We present the performance benefits of differential phase-shift keying (DPSK) modulation in eliminating influence from atmospheric turbulence, especially for coherent free space optical (FSO) communication with a high communication rate. Analytic expression of detected signal is derived, based on which, homodyne detection efficiency is calculated to indicate the performance of wavefront compensation. Considered laser pulses always suffer from atmospheric scattering effect by clouds, intersymbol interference (ISI) in high-speed FSO communication link is analyzed. Correspondingly, the channel equalization method of a binormalized modified constant modulus algorithm based on set-membership filtering (SM-BNMCMA) is proposed to solve the ISI problem. Finally, through the comparison with existing channel equalization methods, its performance benefits of both ISI elimination and convergence speed are verified. The research findings have theoretical significance in a high-speed FSO communication system.

  15. Quality Management and Key Performance Indicators in Oncologic Esophageal Surgery.

    PubMed

    Gockel, Ines; Ahlbrand, Constantin Johannes; Arras, Michael; Schreiber, Elke Maria; Lang, Hauke

    2015-12-01

    Ranking systems and comparisons of quality and performance indicators will be of increasing relevance for complex "high-risk" procedures such as esophageal cancer surgery. The identification of evidence-based standards relevant for key performance indicators in esophageal surgery is essential for establishing monitoring systems and furthermore a requirement to enhance treatment quality. In the course of this review, we analyze the key performance indicators case volume, radicality of resection, and postoperative morbidity and mortality, leading to continuous quality improvement. Ranking systems established on this basis will gain increased relevance in highly complex procedures within the national and international comparison and furthermore improve the treatment of patients with esophageal carcinoma.

  16. Practical issues in quantum-key-distribution postprocessing

    NASA Astrophysics Data System (ADS)

    Fung, Chi-Hang Fred; Ma, Xiongfeng; Chau, H. F.

    2010-01-01

    Quantum key distribution (QKD) is a secure key generation method between two distant parties by wisely exploiting properties of quantum mechanics. In QKD, experimental measurement outcomes on quantum states are transformed by the two parties to a secret key. This transformation is composed of many logical steps (as guided by security proofs), which together will ultimately determine the length of the final secret key and its security. We detail the procedure for performing such classical postprocessing taking into account practical concerns (including the finite-size effect and authentication and encryption for classical communications). This procedure is directly applicable to realistic QKD experiments and thus serves as a recipe that specifies what postprocessing operations are needed and what the security level is for certain lengths of the keys. Our result is applicable to the BB84 protocol with a single or entangled photon source.

  17. APMP supplementary comparison report of absorbed dose rate in tissue for beta radiation (BIPM KCDB: APMP.RI(I)-S2)

    NASA Astrophysics Data System (ADS)

    Kato, M.; Kurosawa, T.; Saito, N.; Kadni, T. B.; Kim, I. J.; Kim, B. C.; Yi, C.-Y.; Pungkun, V.; Chu, C.-H.

    2017-01-01

    The supplementary comparison of absorbed dose rate in tissue for beta radiation (APMP.RI(I)-S2) was performed with five national metrology institutes in 2013 and 2014. Two commercial thin window ionization chambers were used as transfer instruments and circulated among the participants. Two of the NMIs measured the calibration coefficients of the chambers in reference fields produced from Pm-147, Kr-85 and Sr-90/Y-90, while the other three measured those only in Sr-90/Y-90 beta-particle field. The degree of equivalence for the participants was determined and this comparison verifies the calibration capabilities of the participating laboratories. In addition, most of the results of this comparison are consistent with another international comparison (EUROMET.RI(I)-S2) reported before this work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Finite-key analysis for quantum key distribution with weak coherent pulses based on Bernoulli sampling

    NASA Astrophysics Data System (ADS)

    Kawakami, Shun; Sasaki, Toshihiko; Koashi, Masato

    2017-07-01

    An essential step in quantum key distribution is the estimation of parameters related to the leaked amount of information, which is usually done by sampling of the communication data. When the data size is finite, the final key rate depends on how the estimation process handles statistical fluctuations. Many of the present security analyses are based on the method with simple random sampling, where hypergeometric distribution or its known bounds are used for the estimation. Here we propose a concise method based on Bernoulli sampling, which is related to binomial distribution. Our method is suitable for the Bennett-Brassard 1984 (BB84) protocol with weak coherent pulses [C. H. Bennett and G. Brassard, Proceedings of the IEEE Conference on Computers, Systems and Signal Processing (IEEE, New York, 1984), Vol. 175], reducing the number of estimated parameters to achieve a higher key generation rate compared to the method with simple random sampling. We also apply the method to prove the security of the differential-quadrature-phase-shift (DQPS) protocol in the finite-key regime. The result indicates that the advantage of the DQPS protocol over the phase-encoding BB84 protocol in terms of the key rate, which was previously confirmed in the asymptotic regime, persists in the finite-key regime.

  19. Feasibility of satellite quantum key distribution

    NASA Astrophysics Data System (ADS)

    Bonato, C.; Tomaello, A.; Da Deppo, V.; Naletto, G.; Villoresi, P.

    2009-04-01

    In this paper, we present a novel analysis of the feasibility of quantum key distribution between a LEO satellite and a ground station. First of all, we study signal propagation through a turbulent atmosphere for uplinks and downlinks, discussing the contribution of beam spreading and beam wandering. Then we introduce a model for the background noise of the channel during night-time and day-time, calculating the signal-to-noise ratio for different configurations. We also discuss the expected error-rate due to imperfect polarization compensation in the channel. Finally, we calculate the expected key generation rate of a secure key for different configurations (uplink, downlink) and for different protocols (BB84 with and without decoy states, entanglement-based Ekert91 protocol).

  20. Comparison of a 50 mL pycnometer and a 500 mL flask, EURAMET.M.FF.S8 (EURAMET 1297)

    NASA Astrophysics Data System (ADS)

    Mićić, Ljiljana; Batista, Elsa

    2018-01-01

    The purpose of this comparison was to compare the results of the participating laboratories in the calibration of 50 mL pycnometer and 500 mL volumetric flask using the gravimetric method. Laboratories were asked to determined the 'contained' volume of the 50 mL pycnometer and of the 500 mL flask at a reference temperature of 20 °C. The gravimetric method was used for both instruments by all laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Principles of visual key construction-with a visual identification key to the Fagaceae of the southeastern United States.

    PubMed

    Kirchoff, Bruce K; Leggett, Roxanne; Her, Va; Moua, Chue; Morrison, Jessica; Poole, Chamika

    2011-01-01

    Advances in digital imaging have made possible the creation of completely visual keys. By a visual key we mean a key based primarily on images, and that contains a minimal amount of text. Characters in visual keys are visually, not verbally defined. In this paper we create the first primarily visual key to a group of taxa, in this case the Fagaceae of the southeastern USA. We also modify our recently published set of best practices for image use in illustrated keys to make them applicable to visual keys. Photographs of the Fagaceae were obtained from internet and herbarium databases or were taken specifically for this project. The images were printed and then sorted into hierarchical groups. These hierarchical groups of images were used to create the 'couplets' in the key. A reciprocal process of key creation and testing was used to produce the final keys. Four keys were created, one for each of the parts-leaves, buds, fruits and bark. Species description pages consisting of multiple images were also created for each of the species in the key. Creation and testing of the key resulted in a modified list of best practices for image use visual keys. The inclusion of images into paper and electronic keys has greatly increased their ease of use. However, virtually all of these keys are still based upon verbally defined, atomistic characters. The creation of primarily visual keys allows us to overcome the well-known limitations of linguistic-based characters and create keys that are much easier to use, especially for botanical novices.

  2. Multi-party Quantum Key Agreement without Entanglement

    NASA Astrophysics Data System (ADS)

    Cai, Bin-Bin; Guo, Gong-De; Lin, Song

    2017-04-01

    A new efficient quantum key agreement protocol without entanglement is proposed. In this protocol, each user encodes his secret key into the traveling particles by performing one of four rotation operations that one cannot perfectly distinguish. In the end, all users can simultaneously obtain the final shared key. The security of the presented protocol against some common attacks is discussed. It is shown that this protocol can effectively protect the privacy of each user and satisfy the requirement of fairness in theory. Moreover, the quantum carriers and the encoding operations used in the protocol can be achieved in realistic physical devices. Therefore, the presented protocol is feasible with current technology.

  3. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S1

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S2

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. EURAMET.M.P-S9: comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Saxholm, S.; Otal, P.; AltintaS, A.; Bermanec, L. G.; Durgut, Y.; Hanrahan, R.; Kocas, I.; Lefkopoulos, A.; Pražák, D.; Sandu, I.; Åetina, J.; Spohr, I.; Steindl, D.; Tammik, K.; Testa, N.

    2016-01-01

    registered as EURAMET project no. 1170 and as a supplementary comparison EURAMET.M.P-S9 in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Comparison of Keyes Punch Biopsy Instrument with Cervical Punch Biopsy Forceps for Diagnosing Cervical Lesions.

    PubMed

    Tyagi, Natasha; Suneja, Amita; Mishra, Kiran; Jain, Sandhya; Vaid, Neelam Bala; Guleria, Kiran

    2017-01-01

    To assess the feasibility and efficacy of Keyes punch biopsy instrument (KP) in diagnosing cervical lesions and compare it with cervical punch biopsy forceps (CP). 75 women having satisfactory colposcopy with abnormal transformation zone were included and paired colposcopic directed biopsies were taken using KP followed by CP from the same target area. It was feasible in all cases to take cervical biopsy with KP after increasing its effective length. The volume of gross specimen obtained by KP was less than CP (0.076 ± 0.097 vs. 0.101 ± 0.156 cm3, p = 0.061), however on microscopic examination, mean length and mean depth of tissue in KP was greater than CP by 0.06 mm (p = 0.810) and 0.14 mm (p = 0.634) respectively. Exact agreement was found with the final surgical specimen in 42% of cases in both the biopsy forceps. KP is almost at par with CP for diagnosing preinvasive cervical lesions and is a useful adjunct to the existing armamentarium of biopsy forceps. © 2016 S. Karger AG, Basel.

  7. Final report on CCQM-K70: Determination of Hg in natural water at a concentration level required by the European environmental quality standard (EQS)

    NASA Astrophysics Data System (ADS)

    Schiel, Detlef; Rienitz, Olaf

    2011-01-01

    of equivalence were calculated. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Activity measurements of the radionuclides 18F and 64Cu for the NIST, USA in the ongoing comparisons BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Nonis, M.; Bergeron, D.; Cessna, J.; Fitzgerald, R.; Pibida, L.; Zimmerman, B.; Fenwick, A.; Ferreira, K.; Keightley, J.; Da Silva, I.

    2017-01-01

    In 2016, comparisons of activity measurements of 18F and 64Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for 64Cu. Ampoules containing about 27 kBq of 18F and 100 kBq of 64Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)β-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for 18F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Bilateral comparison on electric field measurements between TÜBİTAK UME and SASO NMCC

    NASA Astrophysics Data System (ADS)

    Aslan, Çağlar; Alrobaish, Abdullah M.; Şen, Osman

    2017-01-01

    Electromagnetic (EM) probes are widely utilized in the measurement of EM fields for non-ionizing radiation, electromagnetic compatibility (EMC) testing and other applications in the frequency range 5 Hz-60 GHz. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as IEEE 1309. The existing NMIs or emerging NMIs should refer to the international comparison measurements in order to assure the quality of their measurement results. Therefore, the electric field comparison measurements organized by TUBITAK UME were performed between TUBITAK UME and SASO NMCC at the 100 Hz, 1 kHz, 10 MHz, 100 MHz, 1 GHz, 10 GHz and 18 GHz frequencies in order to obtain the correction factors of the electric field probes. The comparison measurements were carried out in accordance with the Technical Protocol prepared by TUBITAK UME. The measurements started in October 2017 and were completed in January 2017. There was good agreement found for the correction factors. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. CCQM-K90, formaldehyde in nitrogen, 2 μmol mol-1 Final report

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Flores, Edgar; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert Ian; Kim, D.; Kim, Y. D.; Lee, S.; Persijn, S.; Konopelko, L. A.; Kustikov, Y. A.; Malginov, A. V.; Chubchenko, I. K.; Klimov, A. Y.; Efremova, O. V.; Zhou, Z.; Possolo, A.; Shimosaka, T.; Brewer, P.; Macé, T.; Ferracci, Valerio; Brown, Richard J. C.; Aoki, Nobuyuki

    2017-01-01

    uncertainty of the trend parameters, as well as how the dispersion of the dates when measurements were made by the participants was taken into account. Upon decision of the participants, the Key Comparison Reference Values were assigned by the BIPM using the largest uncertainty for measurements performed at the BIPM, linear regression without weight to calculate the trend parameters, and not taking into account the dispersion of dates for measurements made by the participant. Each transfer standard was assigned its own reference value and associated expanded uncertainty. An expression for the degree of equivalence between each participating institute and the KCRV was calculated from the comparison results and measurement uncertainties submitted by participating laboratories. Results of the alternative mathematical treatment are presented in annex of this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Key outcomes and addressing remaining challenges--perspectives from a final evaluation of the China GAVI project.

    PubMed

    Yang, Weizhong; Liang, Xiaofeng; Cui, Fuqiang; Li, Li; Hadler, Stephen C; Hutin, Yvan J; Kane, Mark; Wang, Yu

    2013-12-27

    During the China GAVI project, implemented between 2002 and 2010, more than 25 million children received hepatitis B vaccine with the support of project, and the vaccine proved to be safe and effective. With careful consideration for project savings, China and GAVI continually adjusted the budget, additionally allowing the project to spend operational funds to support demonstration projects to improve timely birth dose (TBD), conduct training of EPI staff, and to monitor the project impact. Results from the final evaluation indicated the achievement of key outcomes. As a result of government co-investment, human resources at county level engaged in hepatitis B vaccination increased from 29 per county on average in 2002 to 66 in 2009. All project counties funded by the GAVI project use auto-disable syringes for hepatitis B vaccination and other vaccines. Surveyed hepatitis B vaccine coverage increased from 71% in 2002 to 93% in 2009 among infants. The HBsAg prevalence declined from 9.67% in 1992 to 0.96% in 2006 among children under 5 years of age. However, several important issues remain: (1) China still accounts for the largest annual number of perinatal HBV infections (estimated 84,121) in the WHO WPR region; (2) China still lacks a clear national policy for safe injection of vaccines; (3) vaccination of high risk adults and protection of health care workers are still not implemented; (4) hepatitis B surveillance needs to be refined to more accurately monitor acute hepatitis B; and (5) a program for treatment of persons with chronic HBV infection is needed. Recommendations for future hepatitis B control include: using the lessons learned from the China GAVI project for future introductions of new vaccines; addressing unmet needs with a second generation hepatitis B program to reach every infant, including screening mothers, and providing HBIG for infants born to HBsAg positive mothers; expanding vaccination to high risk adults; addressing remaining unsafe

  12. Key Largo Limestone revisited: Pleistocene shelf-edge facies, Florida Keys, USA

    USGS Publications Warehouse

    Gray, Multer H.; Gischler, E.; Lundberg, J.; Simmons, K.R.; Shinn, E.A.

    2002-01-01

    New dates and analysis of 12 deep and 57 shallow cores allow a more detailed interpretation of the Pleistocene shelf edge of the Florida Platform as found in various facies of the Key Largo Limestone beneath the Florida Keys. In this study a three-phase evolution of the Quaternary units (Q1-Q5) of the Key Largo is presented with new subdivision of the Q5. (1) In the first phase, the Q1 and Q2 (perhaps deposited during oxygen-isotope stage 11) deep-water quartz-rich environment evolved into a shallow carbonate phase. (2) Subsequently, a Q3 (presumably corresponding to oxygen-isotope stage 9) flourishing reef and productive high-platform sediment phase developed. (3) Finally, a Q4 and Q5 (corresponding to oxygen-isotope stages 7 and 5) stabilization phase occured with reefs and leeward productive lagoons, followed by lower sea levels presenting a sequence of younger (isotope substages 5c, 5a) shelf-margin wedges, sediment veneers and outlier reefs. The Key Largo Limestone provides an accessible model of a carbonate shelf edge with fluctuating water depth, bordering a deep seaward basin for a period of at least 300 ka. During this time, at least four onlaps/offlaps, often separated by periods of karst development with associated diagenetic alterations, took place. The story presented by this limestone not only allows a better understanding of the history of south Florida but also aids in the interpretation of similar persistent shelf-edge sites bordering deep basins in other areas.

  13. Public Key-Based Need-to-Know Authorization Engine Final Report CRADA No. TSB-1553-98

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mark, R.; Williams, R.

    The goals of this project were to develop a public key-based authentication service plug-in based on LLNL's requirements, integrate the public key-based authentication with the Intra Verse authorization service adn the LLNL NTK server by developing a full-featured version of the prototyped Intra Verse need-to-know plug in; and to test the authorization and need-to-know plug-in in a secured extranet prototype among selected national Labs.

  14. Bit-Oriented Quantum Public-Key Cryptosystem Based on Bell States

    NASA Astrophysics Data System (ADS)

    Wu, WanQing; Cai, QingYu; Zhang, HuanGuo; Liang, XiaoYan

    2018-02-01

    Quantum public key encryption system provides information confidentiality using quantum mechanics. This paper presents a quantum public key cryptosystem (Q P K C) based on the Bell states. By H o l e v o's theorem, the presented scheme provides the security of the secret key using one-wayness during the QPKC. While the QPKC scheme is information theoretic security under chosen plaintext attack (C P A). Finally some important features of presented QPKC scheme can be compared with other QPKC scheme.

  15. Bit-Oriented Quantum Public-Key Cryptosystem Based on Bell States

    NASA Astrophysics Data System (ADS)

    Wu, WanQing; Cai, QingYu; Zhang, HuanGuo; Liang, XiaoYan

    2018-06-01

    Quantum public key encryption system provides information confidentiality using quantum mechanics. This paper presents a quantum public key cryptosystem ( Q P K C) based on the Bell states. By H o l e v o' s theorem, the presented scheme provides the security of the secret key using one-wayness during the QPKC. While the QPKC scheme is information theoretic security under chosen plaintext attack ( C P A). Finally some important features of presented QPKC scheme can be compared with other QPKC scheme.

  16. 6. September 1971 DETAIL VIEW OF CHAIN PADLOCK AND KEY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. September 1971 DETAIL VIEW OF CHAIN PADLOCK AND KEY TO SECURE DOOR TO MAIN CELL BLOCK, NOTE STANDARD MODERN PADLOCK FOR SIZE COMPARISON - Jefferson County Jail & Sheriff's Office, Courthouse Square, Madison, Jefferson County, IN

  17. Automatic video shot boundary detection using k-means clustering and improved adaptive dual threshold comparison

    NASA Astrophysics Data System (ADS)

    Sa, Qila; Wang, Zhihui

    2018-03-01

    At present, content-based video retrieval (CBVR) is the most mainstream video retrieval method, using the video features of its own to perform automatic identification and retrieval. This method involves a key technology, i.e. shot segmentation. In this paper, the method of automatic video shot boundary detection with K-means clustering and improved adaptive dual threshold comparison is proposed. First, extract the visual features of every frame and divide them into two categories using K-means clustering algorithm, namely, one with significant change and one with no significant change. Then, as to the classification results, utilize the improved adaptive dual threshold comparison method to determine the abrupt as well as gradual shot boundaries.Finally, achieve automatic video shot boundary detection system.

  18. International comparison CCQM-K84—carbon monoxide in synthetic air at ambient level

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Moon, Dongmin; Lee, Jinbok; Lim, Jeongsik; Hall, Brad; Novelli, Paul; Brewer, Paul J.; Miller, Michael; Murugun, Arul; Doval Minarro, Marta; Qiao, Han; Shuguo, Hu; Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Pankratov, V. V.; Wasserman, I. I.; Zav'yalov, S. V.; Efremova, O. V.; Pavlov, M. V.; Mitchell, Gerald; Guenther, Frank; Walden, Jari; Aoki, Nobuyuki; Shimosaka, Takuya; Tatiana, Mace; Lagler, F.; Borowiak, Annette

    2017-01-01

    traceability to a single scale of CO between NMIs by means of harmonizing the results from different national standards. The Empa result lies in a different report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Update of the BIPM comparison BIPM.RI(II)-K1.Cu-64 of activity measurements of the radionuclide 64Cu to include the 2009 results of the CMI-IIR (Czech Rep.) and the NPL (UK), the 2010 result of the LNE-LNHB (France) and the 2011 result of the ENEA-INMRI (Italy)

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Ratel, G.; Courte, S.; Sochorovà, J.; Auerbach, P.; Keightley, J.; Johansson, L.; Bakhshandeiar, E.; Cassette, P.; Moune, M.; Capogni, M.; De Felice, P.

    2013-01-01

    Since 2009, four national metrology institutes (NMI) have submitted four samples of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Cu-64. The values of the activity submitted were between about 3 MBq and 260 MBq. There are now five results in the BIPM.RI(II)-K1.Cu-64 comparison. A key comparison reference value (KCRV) has been calculated for the first time for this nuclide. The degrees of equivalence between each equivalent activity measured in the SIR and the KCRV have been calculated and the results are given in the form of a table. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Evaluation of the MyWellness Key accelerometer.

    PubMed

    Herrmann, S D; Hart, T L; Lee, C D; Ainsworth, B E

    2011-02-01

    to examine the concurrent validity of the Technogym MyWellness Key accelerometer against objective and subjective physical activity (PA) measures. randomised, cross-sectional design with two phases. The laboratory phase compared the MyWellness Key with the ActiGraph GT1M and the Yamax SW200 Digiwalker pedometer during graded treadmill walking, increasing speed each minute. The free-living phase compared the MyWellness Key with the ActiGraph, Digiwalker, Bouchard Activity cord (BAR) and Global Physical Activity Questionnaire (GPAQ) for seven continuous days. Data were analysed using Spearman rank-order correlation coefficients for all comparisons. laboratory and free-living phases. sixteen participants randomly stratified from 41 eligible respondents by sex (n=8 men; n=8 women) and PA levels (n=4 low, n=8 middle and n=4 high active). there was a strong association between the MyWellness Key and the ActiGraph accelerometer during controlled graded treadmill walking (r=0.91, p<0.01) and in free-living settings (r=0.73-0.76 for light to vigorous PA, respectively, p<0.01). No associations were observed between the MyWellness Key and the BAR and GPAQ (p>0.05). the MyWellness Key has a high concurrent validity with the ActiGraph accelerometer to detect PA in both controlled laboratory and free-living settings.

  1. High-efficiency reconciliation for continuous variable quantum key distribution

    NASA Astrophysics Data System (ADS)

    Bai, Zengliang; Yang, Shenshen; Li, Yongmin

    2017-04-01

    Quantum key distribution (QKD) is the most mature application of quantum information technology. Information reconciliation is a crucial step in QKD and significantly affects the final secret key rates shared between two legitimate parties. We analyze and compare various construction methods of low-density parity-check (LDPC) codes and design high-performance irregular LDPC codes with a block length of 106. Starting from these good codes and exploiting the slice reconciliation technique based on multilevel coding and multistage decoding, we realize high-efficiency Gaussian key reconciliation with efficiency higher than 95% for signal-to-noise ratios above 1. Our demonstrated method can be readily applied in continuous variable QKD.

  2. Social Comparison Processes in Organizations

    ERIC Educational Resources Information Center

    Greenberg, Jerald; Ashton-James, Claire E.; Ashkanasy, Neal M.

    2007-01-01

    We systematically analyze the role of social comparison processes in organizations. Specifically, we describe how social comparison processes have been used to explain six key areas of organizational inquiry: (1) organizational justice, (2) performance appraisal, (3) virtual work environments, (4) affective behavior in the workplace, (5) stress,…

  3. 1979-80 Internal Revenue Service Comparison Study. Final Report.

    ERIC Educational Resources Information Center

    Applied Management Sciences, Inc., Silver Spring, MD.

    Application forms for the Basic Educational Opportunity Grant (BEOG) program for 1979-1980 were compared to 1978 tax forms filed with the Internal Revenue Service (IRS). Comparisons were also made to data from similar 1974-1975 and 1976-1977 studies. Based on a sample of 407,596 applicants, findings include the following: between 1976-1977 and…

  4. EURAMET.M.P-S9 / EURAMET 1170, LOOP2. Comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Otal, P.; Boineau, F.; Medina, N.; Pražák, D.; Wüthrich, C.; Saxholm, S.; Sabuga, W.; Kocas, I.; Durgut, Y.

    2017-01-01

    This report gives the results of a comparison of pressure standards of seven European National Metrology institutes in the range of negative gauge pressure from -950 hPa to 0 hPa. This comparison was piloted by LNE and was carried out from January 2011 to March 2012. This work is a part of the EURAMET project 1170 and is registered as a supplementary comparison EURAMET.M.P-S9. The transfer standard used was a pressure monitor RPM4 A160Ks manufactured by DH Instruments Inc., with a resolution of 0.1 Pa. The reference values have been determined from the weighted mean of the deviations reported by the participants for each specified pressure. Seventy-three of the seventy-seven values (96%) reported by the laboratories agree with the reference values within the expanded uncertainties with a coverage factor k = 2. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Results of the supplementary comparison SIM.M.FF-S12 for volume of liquids at 20 L

    NASA Astrophysics Data System (ADS)

    Maldonado, M.; Castillo, E.; Rodríguez, L. D.

    2018-01-01

    A supplementary comparison was performed in order to compare national measurement systems to determine volume of liquids, particularly at fixed volume of 20 L. The participants were CENAM (Mexico), LACOMET (Costa Rica) and RECOPE (Costa Rica). The measurements were carried out from October 2016 to June 2017. The chosen value of volume (20 L) is representative of the Calibration and Measurement Capabilities (CMCs) declared by the three participants. The transfer standard (TS) was a stainless steel pipette for volume at 20 L. Prior to the beginning of the comparison, the TS was tested by CENAM. The results of the test phase showed excellent values for both repeatability and reproducibility. During the SIM.M.FF-S12, the results of the laboratories showed good agreement with the reference values. The best estimation of the measurands, as reported by the participants, showed a +/- 0.0022 % as the largest difference among the laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. A Comparison of Attitudes and Final Grades among Freshman Dental Students.

    ERIC Educational Resources Information Center

    Lee, Mickey M.; And Others

    1981-01-01

    A study examined students' change in attitudes toward dental education, themselves, and gross anatomy based on their experience in a difficult anatomy course and their final grades. Change occurred only in their attitudes about dental education, but it is concluded that specific aspects of the environment can be used to predict a final grade. (MSE)

  7. Authenticated multi-user quantum key distribution with single particles

    NASA Astrophysics Data System (ADS)

    Lin, Song; Wang, Hui; Guo, Gong-De; Ye, Guo-Hua; Du, Hong-Zhen; Liu, Xiao-Fen

    2016-03-01

    Quantum key distribution (QKD) has been growing rapidly in recent years and becomes one of the hottest issues in quantum information science. During the implementation of QKD on a network, identity authentication has been one main problem. In this paper, an efficient authenticated multi-user quantum key distribution (MQKD) protocol with single particles is proposed. In this protocol, any two users on a quantum network can perform mutual authentication and share a secure session key with the assistance of a semi-honest center. Meanwhile, the particles, which are used as quantum information carriers, are not required to be stored, therefore the proposed protocol is feasible with current technology. Finally, security analysis shows that this protocol is secure in theory.

  8. Entropy Driven Self-Assembly in Charged Lock-Key Particles.

    PubMed

    Odriozola, Gerardo; Lozada-Cassou, Marcelo

    2016-07-07

    In this work we study the lock-key model successfully used in supramolecular chemistry and particles self-assembly and gain further insight into the infinite diluted limit of the lock and key, depletant mediated, effective attraction. We discuss the depletant forces and entropy approaches to self-assembly and give details on the different contributions to the net force for a charged lock and key pair immersed in a solvent plus a primitive model electrolyte. We show a strong correlation of the force components behavior and the underlying processes of co-ion and solvent release from the cavity. In addition, we put into context the universal behavior observed for the energy-distance curves when changing the lock and key to solvent size ratio. Basically, we now show that this behavior is not always achieved and depends on the particular system geometry. Finally, we present a qualitative good agreement with experiments when changing the electrolyte concentration, valence, and cavity-key size ratio.

  9. Comparisons between Intel 386 and i486 microprecessors

    NASA Technical Reports Server (NTRS)

    Liu, Yuan-Kwei

    1989-01-01

    A quick and preliminary comparison is made between the Intel 386 and i486 microprocessors. The following topics are discussed: the i486 key elements, comparison of instruction set architecture, the i486 on-chip cache characteristics, the i486 multiprocessor support, comparison of performance, comparison of power consumption, comparison of radiation hardening potential, and recommendations for the Space Station Freedom (SSF) Data Management System (DMS).

  10. Standardization of Tc-99 by two methods and participation at the CCRI(II)-K2. Tc-99 comparison.

    PubMed

    Sahagia, M; Antohe, A; Ioan, R; Luca, A; Ivan, C

    2014-05-01

    The work accomplished within the participation at the 2012 key comparison of Tc-99 is presented. The solution was standardized for the first time in IFIN-HH by two methods: LSC-TDCR and 4π(PC)β-γ efficiency tracer. The methods are described and the results are compared. For the LSC-TDCR method, the program TDCR07c, written and provided by P. Cassette, was used for processing the measurement data. The results are 2.1% higher than when applying the TDCR06b program; the higher value, calculated with the software TDCR07c, was used for reporting the final result in the comparison. The tracer used for the 4π(PC)β-γ efficiency tracer method was a standard (60)Co solution. The sources were prepared from the mixture (60)Co+(99)Tc solution and a general extrapolation curve, type: N(βTc-99)/(M)(Tc-99)=f [1-ε(Co-60)], was drawn. This value was not used for the final result of the comparison. The difference between the values of activity concentration obtained by the two methods was within the limit of the combined standard uncertainty of the difference of these two results. © 2013 Published by Elsevier Ltd.

  11. Satellite-to-Ground Entanglement-Based Quantum Key Distribution.

    PubMed

    Yin, Juan; Cao, Yuan; Li, Yu-Huai; Ren, Ji-Gang; Liao, Sheng-Kai; Zhang, Liang; Cai, Wen-Qi; Liu, Wei-Yue; Li, Bo; Dai, Hui; Li, Ming; Huang, Yong-Mei; Deng, Lei; Li, Li; Zhang, Qiang; Liu, Nai-Le; Chen, Yu-Ao; Lu, Chao-Yang; Shu, Rong; Peng, Cheng-Zhi; Wang, Jian-Yu; Pan, Jian-Wei

    2017-11-17

    We report on entanglement-based quantum key distribution between a low-Earth-orbit satellite equipped with a space borne entangled-photon source and a ground observatory. One of the entangled photons is measured locally at the satellite, and the other one is sent via a down link to the receiver in the Delingha ground station. The link attenuation is measured to vary from 29 dB at 530 km to 36 dB at 1000 km. We observe that the two-photon entanglement survives after being distributed between the satellite and the ground, with a measured state fidelity of ≥0.86. We then perform the entanglement-based quantum key distribution protocol and obtain an average final key rate of 3.5  bits/s at the distance range of 530-1000 km.

  12. Tight finite-key analysis for quantum cryptography

    PubMed Central

    Tomamichel, Marco; Lim, Charles Ci Wen; Gisin, Nicolas; Renner, Renato

    2012-01-01

    Despite enormous theoretical and experimental progress in quantum cryptography, the security of most current implementations of quantum key distribution is still not rigorously established. One significant problem is that the security of the final key strongly depends on the number, M, of signals exchanged between the legitimate parties. Yet, existing security proofs are often only valid asymptotically, for unrealistically large values of M. Another challenge is that most security proofs are very sensitive to small differences between the physical devices used by the protocol and the theoretical model used to describe them. Here we show that these gaps between theory and experiment can be simultaneously overcome by using a recently developed proof technique based on the uncertainty relation for smooth entropies. PMID:22252558

  13. Tight finite-key analysis for quantum cryptography.

    PubMed

    Tomamichel, Marco; Lim, Charles Ci Wen; Gisin, Nicolas; Renner, Renato

    2012-01-17

    Despite enormous theoretical and experimental progress in quantum cryptography, the security of most current implementations of quantum key distribution is still not rigorously established. One significant problem is that the security of the final key strongly depends on the number, M, of signals exchanged between the legitimate parties. Yet, existing security proofs are often only valid asymptotically, for unrealistically large values of M. Another challenge is that most security proofs are very sensitive to small differences between the physical devices used by the protocol and the theoretical model used to describe them. Here we show that these gaps between theory and experiment can be simultaneously overcome by using a recently developed proof technique based on the uncertainty relation for smooth entropies.

  14. Key Frame Extraction in the Summary Space.

    PubMed

    Li, Xuelong; Zhao, Bin; Lu, Xiaoqiang; Xuelong Li; Bin Zhao; Xiaoqiang Lu; Lu, Xiaoqiang; Li, Xuelong; Zhao, Bin

    2018-06-01

    Key frame extraction is an efficient way to create the video summary which helps users obtain a quick comprehension of the video content. Generally, the key frames should be representative of the video content, meanwhile, diverse to reduce the redundancy. Based on the assumption that the video data are near a subspace of a high-dimensional space, a new approach, named as key frame extraction in the summary space, is proposed for key frame extraction in this paper. The proposed approach aims to find the representative frames of the video and filter out similar frames from the representative frame set. First of all, the video data are mapped to a high-dimensional space, named as summary space. Then, a new representation is learned for each frame by analyzing the intrinsic structure of the summary space. Specifically, the learned representation can reflect the representativeness of the frame, and is utilized to select representative frames. Next, the perceptual hash algorithm is employed to measure the similarity of representative frames. As a result, the key frame set is obtained after filtering out similar frames from the representative frame set. Finally, the video summary is constructed by assigning the key frames in temporal order. Additionally, the ground truth, created by filtering out similar frames from human-created summaries, is utilized to evaluate the quality of the video summary. Compared with several traditional approaches, the experimental results on 80 videos from two datasets indicate the superior performance of our approach.

  15. Development and pretest of key visual imagery in a campaign for the prevention of child maltreatment.

    PubMed

    Charest, Émilie; Gagné, Marie-Hélène; Goulet, Julie

    2017-08-01

    This article discusses the development and pretesting of key visual imagery in a promotional campaign developed in Quebec, Canada. This campaign is the media-based component of a broader prevention strategy involving the use of the Triple P program (Sanders, 1999). The purpose was to pretest with parents the preliminary version of a poster that uses the campaign's key visual imagery prior to final production. In total, 26 parents from the regions of Quebec City and Montreal participated in four focus groups. Two general themes emerged from the focus groups: (i) emotions and reactions arising from the key visual imagery; and (ii) comprehension of the message being conveyed. Based on this information, recommendations were made to the marketing agency, which then modified the campaign's key visual imagery and proposed a final layout.

  16. Key Elements of a Good Mathematics Lesson as Seen by Japanese Junior High School Teachers

    ERIC Educational Resources Information Center

    Ebaeguin, Marlon; Stephens, Max

    2016-01-01

    This study makes a comparison between what literature on Japanese Lesson Study suggests are key elements of a good mathematics lesson and what junior high school mathematics teachers in Japan value in planning their lessons. The teachers' strong consensus in their endorsements of these key elements explains why Japanese teachers strongly support…

  17. APMP.QM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    Lin, Tsai-Yin; Liu, Hsin-Wang; Huang, Chiung-Kun; Kang, Namgoo; Bae, Hyun Kil; Woo, Jin Chun; Bi, Zhe; Zhou, Zeyi; Sinweeruthai, Ratirat; Wongjuk, Arnuttachai; Li, Hou; Beng Keat, Teo; Hui, Liu; Wu, Thomas; Hock Ann, Chua; Smeulders, Damian; Briton McCallum, John; Tendai Satumba, Raymond; Shimosaka, Takuya; Matsumoto, Nobuhiro; Kadir, Haslina Abdul; Fauzi Ahmad, Mohamad; Nasir, Noor Hidaya Abdul; Nishino, Tomoe; Akima, Dai; Uehara, Shinji

    2018-01-01

    This document describes the result of a key comparison for propane in nitrogen. The nominal amount-of-substance fraction of propane is 1000 μmol/mol. The comparison aimed to assess the measurement capability of participants in gas analysis. Nine NMIs or DIs participated in the comparison. CERI participated in a key comparison CCQM-K111—propane in nitrogen, and coordinated this key comparison. Therefore, every participants' results of this comparison are linking to the CCQM-K111. Gravimetric values of the samples were used as key comparison reference values (KCRVs). Measured values of eight participants were within +/- 0.25 % of the KCRVs. Many participants reported purity or impurity analysis of materials. These results are also able to assess the participants' capability of the analysis. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Long-distance quantum key distribution with imperfect devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lo Piparo, Nicoló; Razavi, Mohsen

    2014-12-04

    Quantum key distribution over probabilistic quantum repeaters is addressed. We compare, under practical assumptions, two such schemes in terms of their secure key generation rate per memory, R{sub QKD}. The two schemes under investigation are the one proposed by Duan et al. in [Nat. 414, 413 (2001)] and that of Sangouard et al. proposed in [Phys. Rev. A 76, 050301 (2007)]. We consider various sources of imperfections in the latter protocol, such as a nonzero double-photon probability for the source, dark count per pulse, channel loss and inefficiencies in photodetectors and memories, to find the rate for different nesting levels.more » We determine the maximum value of the double-photon probability beyond which it is not possible to share a secret key anymore. We find the crossover distance for up to three nesting levels. We finally compare the two protocols.« less

  19. Report on AFRIMETS supplementary comparison: platinum resistance thermometer and digital thermometer calibrations against ITS-90 over the range -50 °C to 450 °C (AFRIMETS.T-S1)

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans; Abdelaziz, Yasser; Tesfaye, Fitsum; Egadwa, Wilson; Norranim, Uthai; Rwashana, Simon; Kagoma, Alphonce; Ziagi, Adam; Kwong, Christian Ng Ha; Madeleine, Gilbert

    2017-01-01

    A Regional Metrology Organization (RMO) supplementary comparison of platinum resistance thermometer and digital thermometer (AFRIMETS.T-S1) was carried out by the National Metrology Institute of South Africa (NMISA), National Institute for Standards Egypt (NIS), National Metrology Institute of Ethiopia (NMIE), Kenya Bureau of Standards (KEBS), National Institute of Metrology Thailand (NIMT), Uganda National Bureau of Standards (UNBS), Tanzania Bureau of Standards (TBS), Mauritius Standards Bureau (MSB) and Seychelles Bureau of Standards (SBS) between March 2008 and October 2010. The temperature range of the inter comparison is -50 °C to 450 °C. The results of this comparison are reported here, along with descriptions of the Artefacts and devices used during measurement. This report also presents the uncertainty budget. The results are analysed and normalized error (En) values are reported. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Multi-party quantum key agreement protocol secure against collusion attacks

    NASA Astrophysics Data System (ADS)

    Wang, Ping; Sun, Zhiwei; Sun, Xiaoqiang

    2017-07-01

    The fairness of a secure multi-party quantum key agreement (MQKA) protocol requires that all involved parties are entirely peer entities and can equally influence the outcome of the protocol to establish a shared key wherein no one can decide the shared key alone. However, it is found that parts of the existing MQKA protocols are sensitive to collusion attacks, i.e., some of the dishonest participants can collaborate to predetermine the final key without being detected. In this paper, a multi-party QKA protocol resisting collusion attacks is proposed. Different from previous QKA protocol resisting N-1 coconspirators or resisting 1 coconspirators, we investigate the general circle-type MQKA protocol which can be secure against t dishonest participants' cooperation. Here, t < N. We hope the results of the presented paper will be helpful for further research on fair MQKA protocols.

  1. A Comparison of One Time Pad Random Key Generation using Linear Congruential Generator and Quadratic Congruential Generator

    NASA Astrophysics Data System (ADS)

    Apdilah, D.; Harahap, M. K.; Khairina, N.; Husein, A. M.; Harahap, M.

    2018-04-01

    One Time Pad algorithm always requires a pairing of the key for plaintext. If the length of keys less than a length of the plaintext, the key will be repeated until the length of the plaintext same with the length of the key. In this research, we use Linear Congruential Generator and Quadratic Congruential Generator for generating a random number. One Time Pad use a random number as a key for encryption and decryption process. Key will generate the first letter from the plaintext, we compare these two algorithms in terms of time speed encryption, and the result is a combination of OTP with LCG faster than the combination of OTP with QCG.

  2. Symmetric Blind Information Reconciliation for Quantum Key Distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiktenko, Evgeniy O.; Trushechkin, Anton S.; Lim, Charles Ci Wen

    Quantum key distribution (QKD) is a quantum-proof key-exchange scheme which is fast approaching the communication industry. An essential component in QKD is the information reconciliation step, which is used for correcting the quantum-channel noise errors. The recently suggested blind-reconciliation technique, based on low-density parity-check codes, offers remarkable prospectives for efficient information reconciliation without an a priori quantum bit error rate estimation. We suggest an improvement of the blind-information-reconciliation protocol promoting a significant increase in the efficiency of the procedure and reducing its interactivity. Finally, the proposed technique is based on introducing symmetry in operations of parties, and the consideration ofmore » results of unsuccessful belief-propagation decodings.« less

  3. Symmetric Blind Information Reconciliation for Quantum Key Distribution

    DOE PAGES

    Kiktenko, Evgeniy O.; Trushechkin, Anton S.; Lim, Charles Ci Wen; ...

    2017-10-27

    Quantum key distribution (QKD) is a quantum-proof key-exchange scheme which is fast approaching the communication industry. An essential component in QKD is the information reconciliation step, which is used for correcting the quantum-channel noise errors. The recently suggested blind-reconciliation technique, based on low-density parity-check codes, offers remarkable prospectives for efficient information reconciliation without an a priori quantum bit error rate estimation. We suggest an improvement of the blind-information-reconciliation protocol promoting a significant increase in the efficiency of the procedure and reducing its interactivity. Finally, the proposed technique is based on introducing symmetry in operations of parties, and the consideration ofmore » results of unsuccessful belief-propagation decodings.« less

  4. Measurement-device-independent entanglement-based quantum key distribution

    NASA Astrophysics Data System (ADS)

    Yang, Xiuqing; Wei, Kejin; Ma, Haiqiang; Sun, Shihai; Liu, Hongwei; Yin, Zhenqiang; Li, Zuohan; Lian, Shibin; Du, Yungang; Wu, Lingan

    2016-05-01

    We present a quantum key distribution protocol in a model in which the legitimate users gather statistics as in the measurement-device-independent entanglement witness to certify the sources and the measurement devices. We show that the task of measurement-device-independent quantum communication can be accomplished based on monogamy of entanglement, and it is fairly loss tolerate including source and detector flaws. We derive a tight bound for collective attacks on the Holevo information between the authorized parties and the eavesdropper. Then with this bound, the final secret key rate with the source flaws can be obtained. The results show that long-distance quantum cryptography over 144 km can be made secure using only standard threshold detectors.

  5. Fundamental quantitative security in quantum key generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuen, Horace P.

    2010-12-15

    We analyze the fundamental security significance of the quantitative criteria on the final generated key K in quantum key generation including the quantum criterion d, the attacker's mutual information on K, and the statistical distance between her distribution on K and the uniform distribution. For operational significance a criterion has to produce a guarantee on the attacker's probability of correctly estimating some portions of K from her measurement, in particular her maximum probability of identifying the whole K. We distinguish between the raw security of K when the attacker just gets at K before it is used in a cryptographicmore » context and its composition security when the attacker may gain further information during its actual use to help get at K. We compare both of these securities of K to those obtainable from conventional key expansion with a symmetric key cipher. It is pointed out that a common belief in the superior security of a quantum generated K is based on an incorrect interpretation of d which cannot be true, and the security significance of d is uncertain. Generally, the quantum key distribution key K has no composition security guarantee and its raw security guarantee from concrete protocols is worse than that of conventional ciphers. Furthermore, for both raw and composition security there is an exponential catch-up problem that would make it difficult to quantitatively improve the security of K in a realistic protocol. Some possible ways to deal with the situation are suggested.« less

  6. Evaluation of the durability of 3D printed keys produced by computational processing of image data

    NASA Astrophysics Data System (ADS)

    Straub, Jeremy; Kerlin, Scott

    2016-05-01

    Possession of a working 3D printed key can, for most practical purposes, convince observers that an illicit attempt to gain premises access is authorized. This paper seeks to assess three things. First, work has been performed to determine how easily the data for making models of keys can be obtained through manual measurement. It then presents work done to create a model of the key and determine how easy key modeling could be (particularly after a first key of a given key `blank' has been made). Finally, it seeks to assess the durability of the keys produced using 3D printing.

  7. Multi-party quantum key agreement with five-qubit brown states

    NASA Astrophysics Data System (ADS)

    Cai, Tao; Jiang, Min; Cao, Gang

    2018-05-01

    In this paper, we propose a multi-party quantum key agreement protocol with five-qubit brown states and single-qubit measurements. Our multi-party protocol ensures each participant to contribute equally to the agreement key. Each party performs three single-qubit unitary operations on three qubits of each brown state. Finally, by measuring brown states and decoding the measurement results, all participants can negotiate a shared secret key without classical bits exchange between them. With the analysis of security, our protocol demonstrates that it can resist against both outsider and participant attacks. Compared with other schemes, it also possesses a higher information efficiency. In terms of physical operation, it requires single-qubit measurements only which weakens the hardware requirements of participant and has a better operating flexibility.

  8. Experimental study on discretely modulated continuous-variable quantum key distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen Yong; Zou Hongxin; Chen Pingxing

    2010-08-15

    We present a discretely modulated continuous-variable quantum key distribution system in free space by using strong coherent states. The amplitude noise in the laser source is suppressed to the shot-noise limit by using a mode cleaner combined with a frequency shift technique. Also, it is proven that the phase noise in the source has no impact on the final secret key rate. In order to increase the encoding rate, we use broadband homodyne detectors and the no-switching protocol. In a realistic model, we establish a secret key rate of 46.8 kbits/s against collective attacks at an encoding rate of 10more » MHz for a 90% channel loss when the modulation variance is optimal.« less

  9. Continuous high speed coherent one-way quantum key distribution.

    PubMed

    Stucki, Damien; Barreiro, Claudio; Fasel, Sylvain; Gautier, Jean-Daniel; Gay, Olivier; Gisin, Nicolas; Thew, Rob; Thoma, Yann; Trinkler, Patrick; Vannel, Fabien; Zbinden, Hugo

    2009-08-03

    Quantum key distribution (QKD) is the first commercial quantum technology operating at the level of single quanta and is a leading light for quantum-enabled photonic technologies. However, controlling these quantum optical systems in real world environments presents significant challenges. For the first time, we have brought together three key concepts for future QKD systems: a simple high-speed protocol; high performance detection; and integration both, at the component level and for standard fibre network connectivity. The QKD system is capable of continuous and autonomous operation, generating secret keys in real time. Laboratory and field tests were performed and comparisons made with robust InGaAs avalanche photodiodes and superconducting detectors. We report the first real world implementation of a fully functional QKD system over a 43 dB-loss (150 km) transmission line in the Swisscom fibre optic network where we obtained average real-time distribution rates over 3 hours of 2.5 bps.

  10. A novel key-frame extraction approach for both video summary and video index.

    PubMed

    Lei, Shaoshuai; Xie, Gang; Yan, Gaowei

    2014-01-01

    Existing key-frame extraction methods are basically video summary oriented; yet the index task of key-frames is ignored. This paper presents a novel key-frame extraction approach which can be available for both video summary and video index. First a dynamic distance separability algorithm is advanced to divide a shot into subshots based on semantic structure, and then appropriate key-frames are extracted in each subshot by SVD decomposition. Finally, three evaluation indicators are proposed to evaluate the performance of the new approach. Experimental results show that the proposed approach achieves good semantic structure for semantics-based video index and meanwhile produces video summary consistent with human perception.

  11. Multiparty quantum key agreement protocol based on locally indistinguishable orthogonal product states

    NASA Astrophysics Data System (ADS)

    Jiang, Dong-Huan; Xu, Guang-Bao

    2018-07-01

    Based on locally indistinguishable orthogonal product states, we propose a novel multiparty quantum key agreement (QKA) protocol. In this protocol, the private key information of each party is encoded as some orthogonal product states that cannot be perfectly distinguished by local operations and classical communications. To ensure the security of the protocol with small amount of decoy particles, the different particles of each product state are transmitted separately. This protocol not only can make each participant fairly negotiate a shared key, but also can avoid information leakage in the maximum extent. We give a detailed security proof of this protocol. From comparison result with the existing QKA protocols, we can know that the new protocol is more efficient.

  12. Reinforcer control by comparison-stimulus color and location in a delayed matching-to-sample task.

    PubMed

    Alsop, Brent; Jones, B Max

    2008-05-01

    Six pigeons were trained in a delayed matching-to-sample task involving bright- and dim-yellow samples on a central key, a five-peck response requirement to either sample, a constant 1.5-s delay, and the presentation of comparison stimuli composed of red on the left key and green on the right key or vice versa. Green-key responses were occasionally reinforced following the dimmer-yellow sample, and red-key responses were occasionally reinforced following the brighter-yellow sample. Reinforcer delivery was controlled such that the distribution of reinforcers across both comparison-stimulus color and comparison-stimulus location could be varied systematically and independently across conditions. Matching accuracy was high throughout. The ratio of left to right side-key responses increased as the ratio of left to right reinforcers increased, the ratio of red to green responses increased as the ratio of red to green reinforcers increased, and there was no interaction between these variables. However, side-key biases were more sensitive to the distribution of reinforcers across key location than were comparison-color biases to the distribution of reinforcers across key color. An extension of Davison and Tustin's (1978) model of DMTS performance fit the data well, but the results were also consistent with an alternative theory of conditional discrimination performance (Jones, 2003) that calls for a conceptually distinct quantitative model.

  13. Improvement of "Novel Multiparty Quantum Key Agreement Protocol with GHZ States"

    NASA Astrophysics Data System (ADS)

    Gu, Jun; Hwang, Tzonelih

    2017-10-01

    Quantum key agreement (QKA) protocol is a method for negotiating a fair and secure key among mutually untrusted participants. Recently, Xu et al. (Quantum Inf. Process. 13:2587-2594, 2014) proposed a multi-party QKA protocol based on Greenberger-Horne-Zeilinger (GHZ) states. However, this study points out that Xu et al.'s protocol cannot provide the fairness property. That is, the last involved participant in the protocol can manipulate the final shared secret key without being detected by the other participants. Moreover, according to Yu et al.'s research (2015), Xu et al.'s protocol cannot avoid the public discussion attack too. To avoid these weaknesses, an improved QKA protocol is proposed.

  14. Scalable Authenticated Tree Based Group Key Exchange for Ad-Hoc Groups

    NASA Astrophysics Data System (ADS)

    Desmedt, Yvo; Lange, Tanja; Burmester, Mike

    Task-specific groups are often formed in an ad-hoc manner within large corporate structures, such as companies. Take the following typical scenario: A director decides to set up a task force group for some specific project. An order is passed down the hierarchy where it finally reaches a manager who selects some employees to form the group. The members should communicate in a secure way and for efficiency, a symmetric encryption system is chosen. To establish a joint secret key for the group, a group key exchange (GKE) protocol is used. We show how to use an existing Public Key Infrastructure (PKI) to achieve authenticated GKE by modifying the protocol and particularly by including signatures.

  15. Key-value store with internal key-value storage interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bent, John M.; Faibish, Sorin; Ting, Dennis P. J.

    A key-value store is provided having one or more key-value storage interfaces. A key-value store on at least one compute node comprises a memory for storing a plurality of key-value pairs; and an abstract storage interface comprising a software interface module that communicates with at least one persistent storage device providing a key-value interface for persistent storage of one or more of the plurality of key-value pairs, wherein the software interface module provides the one or more key-value pairs to the at least one persistent storage device in a key-value format. The abstract storage interface optionally processes one or moremore » batch operations on the plurality of key-value pairs. A distributed embodiment for a partitioned key-value store is also provided.« less

  16. Key components of financial-analysis education for clinical nurses.

    PubMed

    Lim, Ji Young; Noh, Wonjung

    2015-09-01

    In this study, we identified key components of financial-analysis education for clinical nurses. We used a literature review, focus group discussions, and a content validity index survey to develop key components of financial-analysis education. First, a wide range of references were reviewed, and 55 financial-analysis education components were gathered. Second, two focus group discussions were performed; the participants were 11 nurses who had worked for more than 3 years in a hospital, and nine components were agreed upon. Third, 12 professionals, including professors, nurse executive, nurse managers, and an accountant, participated in the content validity index. Finally, six key components of financial-analysis education were selected. These key components were as follows: understanding the need for financial analysis, introduction to financial analysis, reading and implementing balance sheets, reading and implementing income statements, understanding the concepts of financial ratios, and interpretation and practice of financial ratio analysis. The results of this study will be used to develop an education program to increase financial-management competency among clinical nurses. © 2015 Wiley Publishing Asia Pty Ltd.

  17. Final report for CCQM-K107: total elements and selenomethionine in human serum

    NASA Astrophysics Data System (ADS)

    Goenaga Infante, Heidi

    2016-01-01

    and solids) at a similar level of performance using the same measurement technique applied in CCQM-K107 provided that there are no additional factors (e.g. blank or dissolution issues). CMC claims based on SeMet measurements in this study may be applied to other biological matrices (e.g., tissues) provided that the concentration range is similar and due diligence is taken to ensure an appropriate extraction process is achieved and species specific spikes are available for quantitation by isotope dilution. Indeed, having accepted such conditions, application to quantitation of other organometallic species and other elements in similar matrices should be possible with the same level of performance. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Measurement-device-independent quantum key distribution with source state errors and statistical fluctuation

    NASA Astrophysics Data System (ADS)

    Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin

    2017-03-01

    We show how to calculate the secure final key rate in the four-intensity decoy-state measurement-device-independent quantum key distribution protocol with both source errors and statistical fluctuations with a certain failure probability. Our results rely only on the range of only a few parameters in the source state. All imperfections in this protocol have been taken into consideration without assuming any specific error patterns of the source.

  19. Longitudinal meta-analysis of NIST pH Standard Reference Materials(®): a complement to pH key comparisons.

    PubMed

    Pratt, Kenneth W

    2015-04-01

    This meta-analysis assesses the long-term (up to 70 years) within-laboratory variation of the NIST pH Standard Reference Material® (SRM) tetroxalate, phthalate, phosphate, borate, and carbonate buffers. Values of ΔpH(S), the difference between the certified pH value, pH(S), of each SRM issue and the mean of all pH(S) values for the given SRM at that Celsius temperature, t, are graphed as a function of the SRM issue and t. In most cases, |ΔpH(S)| < 0.004. Deviations from the nominal base:acid amount (mole) ratio of a buffer yield t-independent, constant shifts in ΔpH(S). The mean ΔpH(S) characterizes such deviations. The corresponding mole fraction of impurity in the conjugate buffer component is generally <0.3 %. Changes in the equipment, personnel, materials, and methodology of the pH(S) measurement yield t-dependent variations. The standard deviation of ΔpH(S) characterizes such changes. Standard deviations of ΔpH(S) are generally 0.0015 or less. The results provide a long-term, single-institution complement to the time-specific, multi-institution results of pH key comparisons administered by the Consultative Committee for Metrology in Chemistry and Biology (CCQM).

  20. Efficient Deployment of Key Nodes for Optimal Coverage of Industrial Mobile Wireless Networks

    PubMed Central

    Li, Xiaomin; Li, Di; Dong, Zhijie; Hu, Yage; Liu, Chengliang

    2018-01-01

    In recent years, industrial wireless networks (IWNs) have been transformed by the introduction of mobile nodes, and they now offer increased extensibility, mobility, and flexibility. Nevertheless, mobile nodes pose efficiency and reliability challenges. Efficient node deployment and management of channel interference directly affect network system performance, particularly for key node placement in clustered wireless networks. This study analyzes this system model, considering both industrial properties of wireless networks and their mobility. Then, static and mobile node coverage problems are unified and simplified to target coverage problems. We propose a novel strategy for the deployment of clustered heads in grouped industrial mobile wireless networks (IMWNs) based on the improved maximal clique model and the iterative computation of new candidate cluster head positions. The maximal cliques are obtained via a double-layer Tabu search. Each cluster head updates its new position via an improved virtual force while moving with full coverage to find the minimal inter-cluster interference. Finally, we develop a simulation environment. The simulation results, based on a performance comparison, show the efficacy of the proposed strategies and their superiority over current approaches. PMID:29439439

  1. Propane in nitrogen, 1000 μmol/mol

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Pankratov, V. V.; Pankov, A. A.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.; Levbarg, O. S.; Kisel, S. P.; Shpilnyi, S. A.; Yakubov, S. Ye; Bakovec, N. V.; Mironchik, A. M.; Aleksandrov, V. V.

    2017-01-01

    This article presents the report on the COOMET key comparison COOMET.QM-K111, which is linking to the appropriate CCQM comparison—CCQM-K111 'Propane in nitrogen 1000 μmol/mol'. CCQM-K111 was carried out in 2014-2016 and it was one of a series of key comparisons in the gas analysis area assessing core competences. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Comparisons of neutrino event generators from an oscillation-experiment perspective

    NASA Astrophysics Data System (ADS)

    Mayer, Nathan

    2015-05-01

    Monte Carlo generators are crucial to the analysis of high energy physics data, ideally giving a baseline comparison between the state-of-art theoretical models and experimental data. Presented here is a comparison between three of final state distributions from the GENIE, Neut, NUANCE, and NuWro neutrino Monte Carlo event generators. The final state distributions chosen for comparison are: the electromagnetic energy fraction in neutral current interactions, the energy of the leading π0 vs. the scattering angle for neutral current interactions, and the muon energy vs. scattering angle of νµ charged current interactions.

  3. Florida Keys

    NASA Image and Video Library

    2002-12-13

    The Florida Keys are a chain of islands, islets and reefs extending from Virginia Key to the Dry Tortugas for about 309 kilometers (192 miles). The keys are chiefly limestone and coral formations. The larger islands of the group are Key West (with its airport), Key Largo, Sugarloaf Key, and Boca Chica Key. A causeway extends from the mainland to Key West. This image was acquired on October 28, 2001, by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) on NASA's Terra satellite. With its 14 spectral bands from the visible to the thermal infrared wavelength region, and its high spatial resolution of 15 to 90 meters (about 50 to 300 feet), ASTER images Earth to map and monitor the changing surface of our planet. http://photojournal.jpl.nasa.gov/catalog/PIA03890

  4. Human action recognition based on spatial-temporal descriptors using key poses

    NASA Astrophysics Data System (ADS)

    Hu, Shuo; Chen, Yuxin; Wang, Huaibao; Zuo, Yaqing

    2014-11-01

    Human action recognition is an important area of pattern recognition today due to its direct application and need in various occasions like surveillance and virtual reality. In this paper, a simple and effective human action recognition method is presented based on the key poses of human silhouette and the spatio-temporal feature. Firstly, the contour points of human silhouette have been gotten, and the key poses are learned by means of K-means clustering based on the Euclidean distance between each contour point and the centre point of the human silhouette, and then the type of each action is labeled for further match. Secondly, we obtain the trajectories of centre point of each frame, and create a spatio-temporal feature value represented by W to describe the motion direction and speed of each action. The value W contains the information of location and temporal order of each point on the trajectories. Finally, the matching stage is performed by comparing the key poses and W between training sequences and test sequences, the nearest neighbor sequences is found and its label supplied the final result. Experiments on the public available Weizmann datasets show the proposed method can improve accuracy by distinguishing amphibious poses and increase suitability for real-time applications by reducing the computational cost.

  5. A free-access online key to identify Amazonian ferns.

    PubMed

    Zuquim, Gabriela; Tuomisto, Hanna; Prado, Jefferson

    2017-01-01

    There is urgent need for more data on species distributions in order to improve conservation planning. A crucial but challenging aspect of producing high-quality data is the correct identification of organisms. Traditional printed floras and dichotomous keys are difficult to use for someone not familiar with the technical jargon. In poorly known areas, such as Amazonia, they also become quickly outdated as new species are described or ranges extended. Recently, online tools have allowed developing dynamic, interactive, and accessible keys that make species identification possible for a broader public. In order to facilitate identifying plants collected in field inventories, we developed an internet-based free-access tool to identify Amazonian fern species. We focused on ferns, because they are easy to collect and their edaphic affinities are relatively well known, so they can be used as an indicator group for habitat mapping. Our key includes 302 terrestrial and aquatic entities mainly from lowland Amazonian forests. It is a free-access key, so the user can freely choose which morphological features to use and in which order to assess them. All taxa are richly illustrated, so specimens can be identified by a combination of character choices, visual comparison, and written descriptions. The identification tool was developed in Lucid 3.5 software and it is available at http://keyserver.lucidcentral.org:8080/sandbox/keys.jsp.

  6. A free-access online key to identify Amazonian ferns

    PubMed Central

    Zuquim, Gabriela; Tuomisto, Hanna; Prado, Jefferson

    2017-01-01

    Abstract There is urgent need for more data on species distributions in order to improve conservation planning. A crucial but challenging aspect of producing high-quality data is the correct identification of organisms. Traditional printed floras and dichotomous keys are difficult to use for someone not familiar with the technical jargon. In poorly known areas, such as Amazonia, they also become quickly outdated as new species are described or ranges extended. Recently, online tools have allowed developing dynamic, interactive, and accessible keys that make species identification possible for a broader public. In order to facilitate identifying plants collected in field inventories, we developed an internet-based free-access tool to identify Amazonian fern species. We focused on ferns, because they are easy to collect and their edaphic affinities are relatively well known, so they can be used as an indicator group for habitat mapping. Our key includes 302 terrestrial and aquatic entities mainly from lowland Amazonian forests. It is a free-access key, so the user can freely choose which morphological features to use and in which order to assess them. All taxa are richly illustrated, so specimens can be identified by a combination of character choices, visual comparison, and written descriptions. The identification tool was developed in Lucid 3.5 software and it is available at http://keyserver.lucidcentral.org:8080/sandbox/keys.jsp. PMID:28781548

  7. Parallel Key Frame Extraction for Surveillance Video Service in a Smart City.

    PubMed

    Zheng, Ran; Yao, Chuanwei; Jin, Hai; Zhu, Lei; Zhang, Qin; Deng, Wei

    2015-01-01

    Surveillance video service (SVS) is one of the most important services provided in a smart city. It is very important for the utilization of SVS to provide design efficient surveillance video analysis techniques. Key frame extraction is a simple yet effective technique to achieve this goal. In surveillance video applications, key frames are typically used to summarize important video content. It is very important and essential to extract key frames accurately and efficiently. A novel approach is proposed to extract key frames from traffic surveillance videos based on GPU (graphics processing units) to ensure high efficiency and accuracy. For the determination of key frames, motion is a more salient feature in presenting actions or events, especially in surveillance videos. The motion feature is extracted in GPU to reduce running time. It is also smoothed to reduce noise, and the frames with local maxima of motion information are selected as the final key frames. The experimental results show that this approach can extract key frames more accurately and efficiently compared with several other methods.

  8. MIST final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gloudemans, J.R.

    1991-08-01

    The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock Wilcox. The unique features of the Babcock Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to addresss the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility -- the once-through integralmore » system (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST program is reported in eleven volumes; Volumes 2 through 8 pertain to groups of Phase 3 tests by type, Volume 9 presents inter-group comparisons. Volume 10 provides comparisons between the RELAP5 MOD2 calculations and MIST observations, and Volume 11 (with addendum) presents the later, Phase 4 tests. This is Volume 1 of the MIST final report, a summary of the entire MIST program. Major topics include: test advisory grop (TAG) issues; facility scaling and design; test matrix; observations; comparisons of RELAP5 calculations to MIST observations; and MIST versus the TAG issues. 11 refs., 29 figs., 9 tabs.« less

  9. Simultaneous transmission for an encrypted image and a double random-phase encryption key

    NASA Astrophysics Data System (ADS)

    Yuan, Sheng; Zhou, Xin; Li, Da-Hai; Zhou, Ding-Fu

    2007-06-01

    We propose a method to simultaneously transmit double random-phase encryption key and an encrypted image by making use of the fact that an acceptable decryption result can be obtained when only partial data of the encrypted image have been taken in the decryption process. First, the original image data are encoded as an encrypted image by a double random-phase encryption technique. Second, a double random-phase encryption key is encoded as an encoded key by the Rivest-Shamir-Adelman (RSA) public-key encryption algorithm. Then the amplitude of the encrypted image is modulated by the encoded key to form what we call an encoded image. Finally, the encoded image that carries both the encrypted image and the encoded key is delivered to the receiver. Based on such a method, the receiver can have an acceptable result and secure transmission can be guaranteed by the RSA cipher system.

  10. Simultaneous transmission for an encrypted image and a double random-phase encryption key.

    PubMed

    Yuan, Sheng; Zhou, Xin; Li, Da-hai; Zhou, Ding-fu

    2007-06-20

    We propose a method to simultaneously transmit double random-phase encryption key and an encrypted image by making use of the fact that an acceptable decryption result can be obtained when only partial data of the encrypted image have been taken in the decryption process. First, the original image data are encoded as an encrypted image by a double random-phase encryption technique. Second, a double random-phase encryption key is encoded as an encoded key by the Rivest-Shamir-Adelman (RSA) public-key encryption algorithm. Then the amplitude of the encrypted image is modulated by the encoded key to form what we call an encoded image. Finally, the encoded image that carries both the encrypted image and the encoded key is delivered to the receiver. Based on such a method, the receiver can have an acceptable result and secure transmission can be guaranteed by the RSA cipher system.

  11. Function key and shortcut key use in airway facilities.

    DOT National Transportation Integrated Search

    2003-02-01

    This document provides information on the function keys and shortcut keys used by systems in the Federal Aviation Administration : Airway Facilities (AF) work environment. It includes a catalog of the function keys and shortcut keys used by each syst...

  12. Report of pilot study CCM.P-P1 for international comparison of absolute pressure measurements in gas from 3 × 10-9 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Yoshida, Hajime; Arai, Kenta; Komatsu, Eiichi; Fujii, Kenichi; Bock, Thomas; Jousten, Karl

    2015-01-01

    A bilateral comparison of absolute gas pressure measurements from 3 × 10-9 Pa to 9 × 10-4 Pa was performed between the National Metrology Institute of Japan (NMIJ) and Physikalisch-Technische Bundesanstalt (PTB). It is a pilot study CCM.P-P1 for the next international comparison in this pressure range to test the stability of ultrahigh vacuum gauges (UHV gauges) as transfer standards. Two spinning rotor gauges (SRGs), an axial-symmetric transmission gauge (ATG), and an extractor gauge (EXG) were used as transfer standards. The calibration ratio of one SRG was sufficiently stable, but the other was not. This result indicates that improvements in the transport mechanism for SRG are needed. The two ionization gauges ATG and EXG, on the other hand, were sufficiently stable. Provisional equivalence of the pressures realized by the primary standards at NMIJ and PTB was found. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM-WGS.

  13. A Security Proof of Measurement Device Independent Quantum Key Distribution: From the View of Information Theory

    NASA Astrophysics Data System (ADS)

    Li, Fang-Yi; Yin, Zhen-Qiang; Li, Hong-Wei; Chen, Wei; Wang, Shuang; Wen, Hao; Zhao, Yi-Bo; Han, Zheng-Fu

    2014-07-01

    Although some ideal quantum key distribution protocols have been proved to be secure, there have been some demonstrations that practical quantum key distribution implementations were hacked due to some real-life imperfections. Among these attacks, detector side channel attacks may be the most serious. Recently, a measurement device independent quantum key distribution protocol [Phys. Rev. Lett. 108 (2012) 130503] was proposed and all detector side channel attacks are removed in this scheme. Here a new security proof based on quantum information theory is given. The eavesdropper's information of the sifted key bits is bounded. Then with this bound, the final secure key bit rate can be obtained.

  14. Quantum key distribution: vulnerable if imperfectly implemented

    NASA Astrophysics Data System (ADS)

    Leuchs, G.

    2013-10-01

    We report several vulnerabilities found in Clavis2, the flagship quantum key distribution (QKD) system from ID Quantique. We show the hacking of a calibration sequence run by Clavis2 to synchronize the Alice and Bob devices before performing the secret key exchange. This hack induces a temporal detection efficiency mismatch in Bob that can allow Eve to break the security of the cryptosystem using faked states. We also experimentally investigate the superlinear behaviour in the single-photon detectors (SPDs) used by Bob. Due to this superlinearity, the SPDs feature an actual multi-photon detection probability which is generally higher than the theoretically-modelled value. We show how this increases the risk of detector control attacks on QKD systems (including Clavis2) employing such SPDs. Finally, we review the experimental feasibility of Trojan-horse attacks. In the case of Clavis2, the objective is to read Bob's phase modulator to acquire knowledge of his basis choice as this information suffices for constructing the raw key in the Scarani-Acin-Ribordy-Gisin 2004 (SARG04) protocol. We work in close collaboration with ID Quantique and for all these loopholes, we notified them in advance. Wherever possible, we or ID Quantique proposed countermeasures and they implemented suitable patches and upgrade their systems.

  15. Simple Web-based interactive key development software (WEBiKEY) and an example key for Kuruna (Poaceae: Bambusoideae).

    PubMed

    Attigala, Lakshmi; De Silva, Nuwan I; Clark, Lynn G

    2016-04-01

    Programs that are user-friendly and freely available for developing Web-based interactive keys are scarce and most of the well-structured applications are relatively expensive. WEBiKEY was developed to enable researchers to easily develop their own Web-based interactive keys with fewer resources. A Web-based multiaccess identification tool (WEBiKEY) was developed that uses freely available Microsoft ASP.NET technologies and an SQL Server database for Windows-based hosting environments. WEBiKEY was tested for its usability with a sample data set, the temperate woody bamboo genus Kuruna (Poaceae). WEBiKEY is freely available to the public and can be used to develop Web-based interactive keys for any group of species. The interactive key we developed for Kuruna using WEBiKEY enables users to visually inspect characteristics of Kuruna and identify an unknown specimen as one of seven possible species in the genus.

  16. Decision Trajectories in Dementia Care Networks: Decisions and Related Key Events.

    PubMed

    Groen-van de Ven, Leontine; Smits, Carolien; Oldewarris, Karen; Span, Marijke; Jukema, Jan; Eefsting, Jan; Vernooij-Dassen, Myrra

    2017-10-01

    This prospective multiperspective study provides insight into the decision trajectories of people with dementia by studying the decisions made and related key events. This study includes three waves of interviews, conducted between July 2010 and July 2012, with 113 purposefully selected respondents (people with beginning to advanced stages of dementia and their informal and professional caregivers) completed in 12 months (285 interviews). Our multilayered qualitative analysis consists of content analysis, timeline methods, and constant comparison. Four decision themes emerged-managing daily life, arranging support, community living, and preparing for the future. Eight key events delineate the decision trajectories of people with dementia. Decisions and key events differ between people with dementia living alone and living with a caregiver. Our study clarifies that decisions relate not only to the disease but to living with the dementia. Individual differences in decision content and sequence may effect shared decision-making and advance care planning.

  17. Quantum key distribution with delayed privacy amplification and its application to the security proof of a two-way deterministic protocol

    NASA Astrophysics Data System (ADS)

    Fung, Chi-Hang Fred; Ma, Xiongfeng; Chau, H. F.; Cai, Qing-Yu

    2012-03-01

    Privacy amplification (PA) is an essential postprocessing step in quantum key distribution (QKD) for removing any information an eavesdropper may have on the final secret key. In this paper, we consider delaying PA of the final key after its use in one-time pad encryption and prove its security. We prove that the security and the key generation rate are not affected by delaying PA. Delaying PA has two applications: it serves as a tool for significantly simplifying the security proof of QKD with a two-way quantum channel, and also it is useful in QKD networks with trusted relays. To illustrate the power of the delayed PA idea, we use it to prove the security of a qubit-based two-way deterministic QKD protocol which uses four states and four encoding operations.

  18. A 24 km fiber-based discretely signaled continuous variable quantum key distribution system.

    PubMed

    Dinh Xuan, Quyen; Zhang, Zheshen; Voss, Paul L

    2009-12-21

    We report a continuous variable key distribution system that achieves a final secure key rate of 3.45 kilobits/s over a distance of 24.2 km of optical fiber. The protocol uses discrete signaling and post-selection to improve reconciliation speed and quantifies security by means of quantum state tomography. Polarization multiplexing and a frequency translation scheme permit transmission of a continuous wave local oscillator and suppression of noise from guided acoustic wave Brillouin scattering by more than 27 dB.

  19. High speed and adaptable error correction for megabit/s rate quantum key distribution.

    PubMed

    Dixon, A R; Sato, H

    2014-12-02

    Quantum Key Distribution is moving from its theoretical foundation of unconditional security to rapidly approaching real world installations. A significant part of this move is the orders of magnitude increases in the rate at which secure key bits are distributed. However, these advances have mostly been confined to the physical hardware stage of QKD, with software post-processing often being unable to support the high raw bit rates. In a complete implementation this leads to a bottleneck limiting the final secure key rate of the system unnecessarily. Here we report details of equally high rate error correction which is further adaptable to maximise the secure key rate under a range of different operating conditions. The error correction is implemented both in CPU and GPU using a bi-directional LDPC approach and can provide 90-94% of the ideal secure key rate over all fibre distances from 0-80 km.

  20. Feasibility Study for Low Drag Acoustic Liners Final Report

    NASA Technical Reports Server (NTRS)

    Riedel, Brian; Wu, Jackie

    2017-01-01

    This report documents the design and structural analysis as a final deliverable for the Phase 1 contract activity. Also included is a community noise test plan, which is a key deliverable for Phase 2. Finally, a high-level estimate (Phase 3 deliverable) is provided for the work statement of Phases 2-4, which covers the build of two inlet test articles, planning and execution of a flight test with the test inlets, as well as data analysis and final documentation. The two test inlets will be compared to the production baseline inlet configuration. There is also a plan to test one of the inlets "hardwalled" using speed tape or some other similar tape to block the acoustic perforations.

  1. Using Insider Research in MEd Final Projects to Bridge the Theory/Practice Gap

    ERIC Educational Resources Information Center

    Arar, Khalid

    2018-01-01

    This paper aims to identify key issues involved in MEd final project supervision and to highlight the potential of supervision from an academic institution to change educational reality through the postgraduate student-teachers' work-based final project as insider researchers in Israeli schools. It draws on analysis of case-study data from two…

  2. Key Developments in Ionic Liquid Crystals.

    PubMed

    Alvarez Fernandez, Alexandra; Kouwer, Paul H J

    2016-05-16

    Ionic liquid crystals are materials that combine the classes of liquid crystals and ionic liquids. The first one is based on the multi-billion-dollar flat panel display industry, whilst the latter quickly developed in the past decades into a family of highly-tunable non-volatile solvents. The combination yields materials with a unique set of properties, but also with many challenges ahead. In this review, we provide an overview of the key concepts in ionic liquid crystals, particularly from a molecular perspective. What are the important molecular parameters that determine the phase behavior? How should they be introduced into the molecules? Finally, which other tools does one have to realize specific properties in the material?

  3. Key Developments in Ionic Liquid Crystals

    PubMed Central

    Alvarez Fernandez, Alexandra; Kouwer, Paul H. J.

    2016-01-01

    Ionic liquid crystals are materials that combine the classes of liquid crystals and ionic liquids. The first one is based on the multi-billion-dollar flat panel display industry, whilst the latter quickly developed in the past decades into a family of highly-tunable non-volatile solvents. The combination yields materials with a unique set of properties, but also with many challenges ahead. In this review, we provide an overview of the key concepts in ionic liquid crystals, particularly from a molecular perspective. What are the important molecular parameters that determine the phase behavior? How should they be introduced into the molecules? Finally, which other tools does one have to realize specific properties in the material? PMID:27196890

  4. Final Technical Report for ARRA Funding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rusack, Roger; Mans, Jeremiah; Poling, Ronald

    Final technical report of the University of Minnesota experimental high energy physics group for ARRA support. The Cryogenic Dark Matter Experiment (CDMS) used the funds received to construct a new passive shield to protect a high-purity germanium detector located in the Soudan mine in Northern Minnesota from cosmic rays. The BESIII and the CMS groups purchased computing hardware to assemble computer farms for data analysis and to generate large volumes of simulated data for comparison with the data collected.

  5. On-line detection of key radionuclides for fuel-rod failure in a pressurized water reactor.

    PubMed

    Qin, Guoxiu; Chen, Xilin; Guo, Xiaoqing; Ni, Ning

    2016-08-01

    For early on-line detection of fuel rod failure, the key radionuclides useful in monitoring must leak easily from failing rods. Yield, half-life, and mass share of fission products that enter the primary coolant also need to be considered in on-line analyses. From all the nuclides that enter the primary coolant during fuel-rod failure, (135)Xe and (88)Kr were ultimately chosen as crucial for on-line monitoring of fuel-rod failure. A monitoring system for fuel-rod failure detection for pressurized water reactor (PWR) based on the LaBr3(Ce) detector was assembled and tested. The samples of coolant from the PWR were measured using the system as well as a HPGe γ-ray spectrometer. A comparison showed the method was feasible. Finally, the γ-ray spectra of primary coolant were measured under normal operations and during fuel-rod failure. The two peaks of (135)Xe (249.8keV) and (88)Kr (2392.1keV) were visible, confirming that the method is capable of monitoring fuel-rod failure on-line. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. High speed and adaptable error correction for megabit/s rate quantum key distribution

    PubMed Central

    Dixon, A. R.; Sato, H.

    2014-01-01

    Quantum Key Distribution is moving from its theoretical foundation of unconditional security to rapidly approaching real world installations. A significant part of this move is the orders of magnitude increases in the rate at which secure key bits are distributed. However, these advances have mostly been confined to the physical hardware stage of QKD, with software post-processing often being unable to support the high raw bit rates. In a complete implementation this leads to a bottleneck limiting the final secure key rate of the system unnecessarily. Here we report details of equally high rate error correction which is further adaptable to maximise the secure key rate under a range of different operating conditions. The error correction is implemented both in CPU and GPU using a bi-directional LDPC approach and can provide 90–94% of the ideal secure key rate over all fibre distances from 0–80 km. PMID:25450416

  7. Simple Web-based interactive key development software (WEBiKEY) and an example key for Kuruna (Poaceae: Bambusoideae)1

    PubMed Central

    Attigala, Lakshmi; De Silva, Nuwan I.; Clark, Lynn G.

    2016-01-01

    Premise of the study: Programs that are user-friendly and freely available for developing Web-based interactive keys are scarce and most of the well-structured applications are relatively expensive. WEBiKEY was developed to enable researchers to easily develop their own Web-based interactive keys with fewer resources. Methods and Results: A Web-based multiaccess identification tool (WEBiKEY) was developed that uses freely available Microsoft ASP.NET technologies and an SQL Server database for Windows-based hosting environments. WEBiKEY was tested for its usability with a sample data set, the temperate woody bamboo genus Kuruna (Poaceae). Conclusions: WEBiKEY is freely available to the public and can be used to develop Web-based interactive keys for any group of species. The interactive key we developed for Kuruna using WEBiKEY enables users to visually inspect characteristics of Kuruna and identify an unknown specimen as one of seven possible species in the genus. PMID:27144109

  8. Comparison versus reminding.

    PubMed

    Tullis, Jonathan G; Goldstone, Robert L

    2016-01-01

    Comparison and reminding have both been shown to support learning and transfer. Comparison is thought to support transfer because it allows learners to disregard non-matching features of superficially different episodes in order to abstract the essential structure of concepts. Remindings promote memory for the individual episodes and generalization because they prompt learners to retrieve earlier episodes during the encoding of later related episodes and to compare across episodes. Across three experiments, we compared the consequences of comparison and reminding on memory and transfer. Participants studied a sequence of related, but superficially different, proverb pairs. In the comparison condition, participants saw proverb pairs presented together and compared their meaning. In the reminding condition, participants viewed proverbs one at a time and retrieved any prior studied proverb that shared the same deep meaning as the current proverb. Experiment 1 revealed that participants in the reminding condition recalled more proverbs than those in the comparison condition. Experiment 2 showed that the mnemonic benefits of reminding persisted over a one-week retention interval. Finally, in Experiment 3, we examined the ability of participants to generalize their remembered information to new items in a task that required participants to identify unstudied proverbs that shared the same meaning as studied proverbs. Comparison led to worse discrimination between proverbs related to studied proverbs and proverbs unrelated to studied proverbs than reminding. Reminding supported better memory for individual instances and transfer to new situations than comparison.

  9. Simulating of the measurement-device independent quantum key distribution with phase randomized general sources

    PubMed Central

    Wang, Qin; Wang, Xiang-Bin

    2014-01-01

    We present a model on the simulation of the measurement-device independent quantum key distribution (MDI-QKD) with phase randomized general sources. It can be used to predict experimental observations of a MDI-QKD with linear channel loss, simulating corresponding values for the gains, the error rates in different basis, and also the final key rates. Our model can be applicable to the MDI-QKDs with arbitrary probabilistic mixture of different photon states or using any coding schemes. Therefore, it is useful in characterizing and evaluating the performance of the MDI-QKD protocol, making it a valuable tool in studying the quantum key distributions. PMID:24728000

  10. An improved scheme on decoy-state method for measurement-device-independent quantum key distribution.

    PubMed

    Wang, Dong; Li, Mo; Guo, Guang-Can; Wang, Qin

    2015-10-14

    Quantum key distribution involving decoy-states is a significant application of quantum information. By using three-intensity decoy-states of single-photon-added coherent sources, we propose a practically realizable scheme on quantum key distribution which approaches very closely the ideal asymptotic case of an infinite number of decoy-states. We make a comparative study between this scheme and two other existing ones, i.e., two-intensity decoy-states with single-photon-added coherent sources, and three-intensity decoy-states with weak coherent sources. Through numerical analysis, we demonstrate the advantages of our scheme in secure transmission distance and the final key generation rate.

  11. An improved scheme on decoy-state method for measurement-device-independent quantum key distribution

    PubMed Central

    Wang, Dong; Li, Mo; Guo, Guang-Can; Wang, Qin

    2015-01-01

    Quantum key distribution involving decoy-states is a significant application of quantum information. By using three-intensity decoy-states of single-photon-added coherent sources, we propose a practically realizable scheme on quantum key distribution which approaches very closely the ideal asymptotic case of an infinite number of decoy-states. We make a comparative study between this scheme and two other existing ones, i.e., two-intensity decoy-states with single-photon-added coherent sources, and three-intensity decoy-states with weak coherent sources. Through numerical analysis, we demonstrate the advantages of our scheme in secure transmission distance and the final key generation rate. PMID:26463580

  12. Novel Multi-Party Quantum Key Agreement Protocol with G-Like States and Bell States

    NASA Astrophysics Data System (ADS)

    Min, Shi-Qi; Chen, Hua-Ying; Gong, Li-Hua

    2018-03-01

    A significant aspect of quantum cryptography is quantum key agreement (QKA), which ensures the security of key agreement protocols by quantum information theory. The fairness of an absolute security multi-party quantum key agreement (MQKA) protocol demands that all participants can affect the protocol result equally so as to establish a shared key and that nobody can determine the shared key by himself/herself. We found that it is difficult for the existing multi-party quantum key agreement protocol to withstand the collusion attacks. Put differently, it is possible for several cooperated and untruthful participants to determine the final key without being detected. To address this issue, based on the entanglement swapping between G-like state and Bell states, a new multi-party quantum key agreement protocol is put forward. The proposed protocol makes full use of EPR pairs as quantum resources, and adopts Bell measurement and unitary operation to share a secret key. Besides, the proposed protocol is fair, secure and efficient without involving a third party quantum center. It demonstrates that the protocol is capable of protecting users' privacy and meeting the requirement of fairness. Moreover, it is feasible to carry out the protocol with existing technologies.

  13. Novel Multi-Party Quantum Key Agreement Protocol with G-Like States and Bell States

    NASA Astrophysics Data System (ADS)

    Min, Shi-Qi; Chen, Hua-Ying; Gong, Li-Hua

    2018-06-01

    A significant aspect of quantum cryptography is quantum key agreement (QKA), which ensures the security of key agreement protocols by quantum information theory. The fairness of an absolute security multi-party quantum key agreement (MQKA) protocol demands that all participants can affect the protocol result equally so as to establish a shared key and that nobody can determine the shared key by himself/herself. We found that it is difficult for the existing multi-party quantum key agreement protocol to withstand the collusion attacks. Put differently, it is possible for several cooperated and untruthful participants to determine the final key without being detected. To address this issue, based on the entanglement swapping between G-like state and Bell states, a new multi-party quantum key agreement protocol is put forward. The proposed protocol makes full use of EPR pairs as quantum resources, and adopts Bell measurement and unitary operation to share a secret key. Besides, the proposed protocol is fair, secure and efficient without involving a third party quantum center. It demonstrates that the protocol is capable of protecting users' privacy and meeting the requirement of fairness. Moreover, it is feasible to carry out the protocol with existing technologies.

  14. Conducting indirect-treatment-comparison and network-meta-analysis studies: report of the ISPOR Task Force on Indirect Treatment Comparisons Good Research Practices: part 2.

    PubMed

    Hoaglin, David C; Hawkins, Neil; Jansen, Jeroen P; Scott, David A; Itzler, Robbin; Cappelleri, Joseph C; Boersma, Cornelis; Thompson, David; Larholt, Kay M; Diaz, Mireya; Barrett, Annabel

    2011-06-01

    Evidence-based health care decision making requires comparison of all relevant competing interventions. In the absence of randomized controlled trials involving a direct comparison of all treatments of interest, indirect treatment comparisons and network meta-analysis provide useful evidence for judiciously selecting the best treatment(s). Mixed treatment comparisons, a special case of network meta-analysis, combine direct evidence and indirect evidence for particular pairwise comparisons, thereby synthesizing a greater share of the available evidence than traditional meta-analysis. This report from the International Society for Pharmacoeconomics and Outcomes Research Indirect Treatment Comparisons Good Research Practices Task Force provides guidance on technical aspects of conducting network meta-analyses (our use of this term includes most methods that involve meta-analysis in the context of a network of evidence). We start with a discussion of strategies for developing networks of evidence. Next we briefly review assumptions of network meta-analysis. Then we focus on the statistical analysis of the data: objectives, models (fixed-effects and random-effects), frequentist versus Bayesian approaches, and model validation. A checklist highlights key components of network meta-analysis, and substantial examples illustrate indirect treatment comparisons (both frequentist and Bayesian approaches) and network meta-analysis. A further section discusses eight key areas for future research. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  15. Quantum key management

    DOEpatents

    Hughes, Richard John; Thrasher, James Thomas; Nordholt, Jane Elizabeth

    2016-11-29

    Innovations for quantum key management harness quantum communications to form a cryptography system within a public key infrastructure framework. In example implementations, the quantum key management innovations combine quantum key distribution and a quantum identification protocol with a Merkle signature scheme (using Winternitz one-time digital signatures or other one-time digital signatures, and Merkle hash trees) to constitute a cryptography system. More generally, the quantum key management innovations combine quantum key distribution and a quantum identification protocol with a hash-based signature scheme. This provides a secure way to identify, authenticate, verify, and exchange secret cryptographic keys. Features of the quantum key management innovations further include secure enrollment of users with a registration authority, as well as credential checking and revocation with a certificate authority, where the registration authority and/or certificate authority can be part of the same system as a trusted authority for quantum key distribution.

  16. Comparison as a Universal Learning Action

    ERIC Educational Resources Information Center

    Merkulova, T. V.

    2016-01-01

    This article explores "comparison" as a universal metasubject learning action, a key curricular element envisaged by the Russian Federal State Educational Standards. Representing the modern learner's fundamental pragmatic skill embedding such core capacities as information processing, critical thinking, robust decision-making, and…

  17. Radiation-Grafted Polymer Electrolyte Membranes for Water Electrolysis Cells: Evaluation of Key Membrane Properties.

    PubMed

    Albert, Albert; Barnett, Alejandro O; Thomassen, Magnus S; Schmidt, Thomas J; Gubler, Lorenz

    2015-10-14

    Radiation-grafted membranes can be considered an alternative to perfluorosulfonic acid (PFSA) membranes, such as Nafion, in a solid polymer electrolyte electrolyzer. Styrene, acrylonitrile, and 1,3-diisopropenylbenzene monomers are cografted into preirradiated 50 μm ethylene tetrafluoroethylene (ETFE) base film, followed by sulfonation to introduce proton exchange sites to the obtained grafted films. The incorporation of grafts throughout the thickness is demonstrated by scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDX) analysis of the membrane cross-sections. The membranes are analyzed in terms of grafting kinetics, ion-exchange capacity (IEC), and water uptake. The key properties of radiation-grafted membranes and Nafion, such as gas crossover, area resistance, and mechanical properties, are evaluated and compared. The plot of hydrogen crossover versus area resistance of the membranes results in a property map that indicates the target areas for membrane development for electrolyzer applications. Tensile tests are performed to assess the mechanical properties of the membranes. Finally, these three properties are combined to establish a figure of merit, which indicates that radiation-grafted membranes obtained in the present study are promising candidates with properties superior to those of Nafion membranes. A water electrolysis cell test is performed as proof of principle, including a comparison to a commercial membrane electrode assembly (MEA).

  18. Multi-Point Combustion System: Final Report

    NASA Technical Reports Server (NTRS)

    Goeke, Jerry; Pack, Spencer; Zink, Gregory; Ryon, Jason

    2014-01-01

    A low-NOx emission combustor concept has been developed for NASA's Environmentally Responsible Aircraft (ERA) program to meet N+2 emissions goals for a 70,000 lb thrust engine application. These goals include 75 percent reduction of LTO NOx from CAEP6 standards without increasing CO, UHC, or smoke from that of current state of the art. An additional key factor in this work is to improve lean combustion stability over that of previous work performed on similar technology in the early 2000s. The purpose of this paper is to present the final report for the NASA contract. This work included the design, analysis, and test of a multi-point combustion system. All design work was based on the results of Computational Fluid Dynamics modeling with the end results tested on a medium pressure combustion rig at the UC and a medium pressure combustion rig at GRC. The theories behind the designs, results of analysis, and experimental test data will be discussed in this report. The combustion system consists of five radially staged rows of injectors, where ten small scale injectors are used in place of a single traditional nozzle. Major accomplishments of the current work include the design of a Multipoint Lean Direct Injection (MLDI) array and associated air blast and pilot fuel injectors, which is expected to meet or exceed the goal of a 75 percent reduction in LTO NOx from CAEP6 standards. This design incorporates a reduced number of injectors over previous multipoint designs, simplified and lightweight components, and a very compact combustor section. Additional outcomes of the program are validation that the design of these combustion systems can be aided by the use of Computational Fluid Dynamics to predict and reduce emissions. Furthermore, the staging of fuel through the individually controlled radially staged injector rows successfully demonstrated improved low power operability as well as improvements in emissions over previous multipoint designs. Additional comparison

  19. Security proof of continuous-variable quantum key distribution using three coherent states

    NASA Astrophysics Data System (ADS)

    Brádler, Kamil; Weedbrook, Christian

    2018-02-01

    We introduce a ternary quantum key distribution (QKD) protocol and asymptotic security proof based on three coherent states and homodyne detection. Previous work had considered the binary case of two coherent states and here we nontrivially extend this to three. Our motivation is to leverage the practical benefits of both discrete and continuous (Gaussian) encoding schemes creating a best-of-both-worlds approach; namely, the postprocessing of discrete encodings and the hardware benefits of continuous ones. We present a thorough and detailed security proof in the limit of infinite signal states which allows us to lower bound the secret key rate. We calculate this is in the context of collective eavesdropping attacks and reverse reconciliation postprocessing. Finally, we compare the ternary coherent state protocol to other well-known QKD schemes (and fundamental repeaterless limits) in terms of secret key rates and loss.

  20. MoKey: A versatile exergame creator for everyday usage.

    PubMed

    Eckert, Martina; López, Marcos; Lázaro, Carlos; Meneses, Juan

    2017-11-27

    Currently, virtual applications for physical exercises are highly appreciated as rehabilitation instruments. This article presents a middleware called "MoKey" (Motion Keyboard), which converts standard off-the-shelf software into exergames (exercise games). A configurable set of gestures, captured by a motion capture camera, is translated into the key strokes required by the chosen software. The present study assesses the tool regarding usability and viability on a heterogeneous group of 11 participants, aged 5 to 51, with moderate to severe disabilities, and mostly bound to a wheelchair. In comparison with FAAST (The Flexible Action and Articulated Skeleton Toolkit), MoKey achieved better results in terms of ease of use and computational load. The viability as an exergame creator tool was proven with help of four applications (PowerPoint®, e-book reader, Skype®, and Tetris). Success rates of up to 91% have been achieved, subjective perception was rated with 4.5 points (from 0-5). The middleware provides increased motivation due to the use of favorite software and the advantage of exploiting it for exercise. Used together with communication software or online games, social inclusion can be stimulated. The therapists can employ the tool to monitor the correctness and progress of the exercises.

  1. Key Issues in Hymenoptera Venom Allergy: An Update.

    PubMed

    Alfaya Arias, T; Soriano Gómis, V; Soto Mera, T; Vega Castro, A; Vega Gutiérrez, J M; Alonso Llamazares, A; Antolín Amérigo, D; Carballada Gonzalez, F J; Dominguez Noche, C; Gutierrez Fernandez, D; Marques Amat, L; Martinez Arcediano, A; Martinez San Ireneo, M; Moreno Ancillo, A; Puente Crespo, Y; Ruiz Leon, B; Sánchez Morillas, L

    In this review, the Hymenoptera Allergy Committee of the SEAIC analyzes the most recent scientific literature addressing problems related to the diagnosis of hymenoptera allergy and to management of venom immunotherapy. Molecular diagnosis and molecular risk profiles are the key areas addressed. The appearance of new species of hymenoptera that are potentially allergenic in Spain and the associated diagnostic and therapeutic problems are also described. Finally, we analyze the issue of mast cell activation syndrome closely related to hymenoptera allergy, which has become a new diagnostic challenge for allergists given its high prevalence in patients with venom anaphylaxis.

  2. Getting Ready for the "School of the Future": Key Questions and Tentative Answers

    NASA Astrophysics Data System (ADS)

    Ott, Michela; Pozzi, Francesca

    This paper explores some key aspects of "today's school", as opposed to those that have characterized "yesterday's school", with the final aim of shedding light on "tomorrow's school". In this direction, the paper puts forward tentative answers to some key questions related to the new characteristics and roles of teachers and students (main actors of the learning process) and the new features/ potentialities of contemporary educational tools which, in turn, require the enactment of innovative pedagogical approaches and educational methods. The emerging picture of the present learning landscape helps in figuring out a future situation where learning possibilities are substantially increased.

  3. Image use in field guides and identification keys: review and recommendations.

    PubMed

    Leggett, Roxanne; Kirchoff, Bruce K

    2011-01-01

    Although illustrations have played an important role in identification keys and guides since the 18th century, their use has varied widely. Some keys lack all illustrations, while others are heavily illustrated. Even within illustrated guides, the way in which images are used varies considerably. Here, we review image use in paper and electronic guides, and establish a set of best practices for image use in illustrated keys and guides. Our review covers image use in both paper and electronic guides, though we only briefly cover apps for mobile devices. With this one exception, we cover the full range of guides, from those that consist only of species descriptions with no keys, to lavishly illustrated technical keys. Emphasis is placed on how images are used, not on the operation of the guides and key, which has been reviewed by others. We only deal with operation when it impacts image use. Few illustrated keys or guides use images in optimal ways. Most include too few images to show taxonomic variation or variation in characters and character states. The use of multiple images allows easier taxon identification and facilitates the understanding of characters. Most images are usually not standardized, making comparison between images difficult. Although some electronic guides allow images to be enlarged, many do not. The best keys and guides use standardized images, displayed at sizes that are easy to see and arranged in a standardized manner so that similar images can be compared across species. Illustrated keys and glossaries should contain multiple images for each character state so that the user can judge variation in the state. Photographic backgrounds should not distract from the subject and, where possible, should be of a standard colour. When used, drawings should be prepared by professional botanical illustrators, and clearly labelled. Electronic keys and guides should allow images to be enlarged so that their details can be seen.

  4. Image use in field guides and identification keys: review and recommendations

    PubMed Central

    Leggett, Roxanne; Kirchoff, Bruce K.

    2011-01-01

    Background and aims Although illustrations have played an important role in identification keys and guides since the 18th century, their use has varied widely. Some keys lack all illustrations, while others are heavily illustrated. Even within illustrated guides, the way in which images are used varies considerably. Here, we review image use in paper and electronic guides, and establish a set of best practices for image use in illustrated keys and guides. Scope Our review covers image use in both paper and electronic guides, though we only briefly cover apps for mobile devices. With this one exception, we cover the full range of guides, from those that consist only of species descriptions with no keys, to lavishly illustrated technical keys. Emphasis is placed on how images are used, not on the operation of the guides and key, which has been reviewed by others. We only deal with operation when it impacts image use. Main points Few illustrated keys or guides use images in optimal ways. Most include too few images to show taxonomic variation or variation in characters and character states. The use of multiple images allows easier taxon identification and facilitates the understanding of characters. Most images are usually not standardized, making comparison between images difficult. Although some electronic guides allow images to be enlarged, many do not. Conclusions The best keys and guides use standardized images, displayed at sizes that are easy to see and arranged in a standardized manner so that similar images can be compared across species. Illustrated keys and glossaries should contain multiple images for each character state so that the user can judge variation in the state. Photographic backgrounds should not distract from the subject and, where possible, should be of a standard colour. When used, drawings should be prepared by professional botanical illustrators, and clearly labelled. Electronic keys and guides should allow images to be enlarged so that

  5. Experimental demonstration of an active phase randomization and monitor module for quantum key distribution

    NASA Astrophysics Data System (ADS)

    Sun, Shi-Hai; Liang, Lin-Mei

    2012-08-01

    Phase randomization is a very important assumption in the BB84 quantum key distribution (QKD) system with weak coherent source; otherwise, eavesdropper may spy the final key. In this Letter, a stable and monitored active phase randomization scheme for the one-way and two-way QKD system is proposed and demonstrated in experiments. Furthermore, our scheme gives an easy way for Alice to monitor the degree of randomization in experiments. Therefore, we expect our scheme to become a standard part in future QKD systems due to its secure significance and feasibility.

  6. Thirteen Hundred and Thirty Days. A Pilot Study of Teacher Time in Key Stage 1. Final Report.

    ERIC Educational Resources Information Center

    Campbell, R. J.; Neill, S. St. J.

    Ninety-five teachers in Key Stage 1 in England and Wales completed a questionnaire and records of time spent on work over a period of 14 consecutive days, resulting in detailed records of 1,330 days of teachers' time. The data are analyzed in terms of overall time spent on work; time distribution; and time spent specifically on teaching,…

  7. Final report on CCQM-K125: elements in infant formula

    NASA Astrophysics Data System (ADS)

    Merrick, J.; Saxby, D.; Dutra, E. S.; Sena, R. C.; Araújo, T. O.; Almeida, M. D.; Yang, L.; Pihillagawa, I. G.; Mester, Z.; Sandoval, S.; Wei, C.; Castillo, M. E. D.; Oster, C.; Fisicaro, P.; Rienitz, O.; Pape, C.; Schulz, U.; Jährling, R.; Görlitz, V.; Lampi, E.; Kakoulides, E.; Sin, D. W. M.; Yip, Y. C.; Tsoi, Y. T.; Zhu, Y.; Okumu, T. O.; Yim, Y. H.; Heo, S. W.; Han, M.; Lim, Y.; Osuna, M. A.; Regalado, L.; Uribe, C.; Buzoianu, M. M.; Duta, S.; Konopelko, L.; Krylov, A.; Shin, R.; Linsky, M.; Botha, A.; Magnusson, B.; Haraldsson, C.; Thiengmanee, U.; Klich, H.; Can, S. Z.; Coskun, F. G.; Tunc, M.; Entwisle, J.; O'Reilly, J.; Hill, S.; Goenaga-Infante, H.; Winchester, M.; Rabb, S. A.; Pérez, R.

    2017-01-01

    CCQM-K125 was organized by the Inorganic Analysis Working Group (IAWG) of CCQM to assess and document the capabilities of the national metrology institutes (NMIs) or the designated institutes (DIs) to measure the mass fractions of trace elements (K, Cu and I) in infant formula. Government Laboratory, Hong Kong SAR (GLHK) acted as the coordinating laboratory. In CCQM-K125, 25 institutes submitted the results for potassium, 24 institutes submitted the results for copper and 8 institutes submitted the results for iodine. For examination of potassium and copper, most of the participants used microwave-assisted acid digestion methods for sample dissolution. A variety of instrumental techniques including inductively coupled plasma mass spectrometry (ICP-MS), isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), inductively coupled plasma optical emission spectrometry (ICP-OES), atomic absorption spectrometry (AAS), flame atomic emission spectrometry (FAES) and microwave plasma atomic emission spectroscopy (MP-AES) were employed by the participants for determination. For analysis of iodine, most of the participants used alkaline extraction methods for sample preparation. ICP-MS and ID-ICP-MS were used by the participants for the determination. Generally, the participants' results of CCQM-K125 were found consistent for all measurands according to their equivalence statements. Except with some extreme values, most of the participants obtained the values of di/U(di) within +/- 1 for the measurands. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Three-factor anonymous authentication and key agreement scheme for Telecare Medicine Information Systems.

    PubMed

    Arshad, Hamed; Nikooghadam, Morteza

    2014-12-01

    Nowadays, with comprehensive employment of the internet, healthcare delivery services is provided remotely by telecare medicine information systems (TMISs). A secure mechanism for authentication and key agreement is one of the most important security requirements for TMISs. Recently, Tan proposed a user anonymity preserving three-factor authentication scheme for TMIS. The present paper shows that Tan's scheme is vulnerable to replay attacks and Denial-of-Service attacks. In order to overcome these security flaws, a new and efficient three-factor anonymous authentication and key agreement scheme for TMIS is proposed. Security and performance analysis shows superiority of the proposed scheme in comparison with previously proposed schemes that are related to security of TMISs.

  9. A brief review on key technologies in the battery management system of electric vehicles

    NASA Astrophysics Data System (ADS)

    Liu, Kailong; Li, Kang; Peng, Qiao; Zhang, Cheng

    2018-04-01

    Batteries have been widely applied in many high-power applications, such as electric vehicles (EVs) and hybrid electric vehicles, where a suitable battery management system (BMS) is vital in ensuring safe and reliable operation of batteries. This paper aims to give a brief review on several key technologies of BMS, including battery modelling, state estimation and battery charging. First, popular battery types used in EVs are surveyed, followed by the introduction of key technologies used in BMS. Various battery models, including the electric model, thermal model and coupled electro-thermal model are reviewed. Then, battery state estimations for the state of charge, state of health and internal temperature are comprehensively surveyed. Finally, several key and traditional battery charging approaches with associated optimization methods are discussed.

  10. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    DTIC Science & Technology

    2018-03-26

    HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...Report March 2016 – August 2017 Approved for public release; distribution is unlimited U.S. Army Natick Soldier Research ...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  11. International and cross-cultural issues: six key challenges for our professions.

    PubMed

    Marshall, Julie

    2003-01-01

    This paper discusses a number of key challenges facing professionals who work with people who have communication disabilities. The challenges are related to working internationally and in a cross-culturally competent way. Each challenge is discussed, drawing on material from a range of sources, including the papers in the final 2003 edition of FOLIA PHONIATRICA ET LOGOPAEDICA ('International and Cross-Cultural Issues'). The challenges discussed cover how experiences from majority world countries can be used to benefit services elsewhere, 'mainstreaming' commitment to cross-cultural competence, learning from relationships with other professionals, influencing research practice, responding to requests to work internationally and finally, dealing with cultural differences that challenge working practices. Some solutions are suggested and additional questions posed. Copyright 2003 S. Karger AG, Basel

  12. Development of balanced key performance indicators for emergency departments strategic dashboards following analytic hierarchical process.

    PubMed

    Safdari, Reza; Ghazisaeedi, Marjan; Mirzaee, Mahboobeh; Farzi, Jebrail; Goodini, Azadeh

    2014-01-01

    Dynamic reporting tools, such as dashboards, should be developed to measure emergency department (ED) performance. However, choosing an effective balanced set of performance measures and key performance indicators (KPIs) is a main challenge to accomplish this. The aim of this study was to develop a balanced set of KPIs for use in ED strategic dashboards following an analytic hierarchical process. The study was carried out in 2 phases: constructing ED performance measures based on balanced scorecard perspectives and incorporating them into analytic hierarchical process framework to select the final KPIs. The respondents placed most importance on ED internal processes perspective especially on measures related to timeliness and accessibility of care in ED. Some measures from financial, customer, and learning and growth perspectives were also selected as other top KPIs. Measures of care effectiveness and care safety were placed as the next priorities too. The respondents placed least importance on disease-/condition-specific "time to" measures. The methodology can be presented as a reference model for development of KPIs in various performance related areas based on a consistent and fair approach. Dashboards that are designed based on such a balanced set of KPIs will help to establish comprehensive performance measurements and fair benchmarks and comparisons.

  13. Leptanilla hypodracos sp. n., a new species of the cryptic ant genus Leptanilla (Hymenoptera, Formicidae) from Singapore, with new distribution data and an updated key to Oriental Leptanilla species

    PubMed Central

    Wong, Mark K. L.; Guénard, Benoit

    2016-01-01

    Abstract A new species of the cryptic and rarely collected ant genus Leptanilla is described. Leptanilla hypodracos sp. n. is the first Leptanilla recorded from Singapore in over a century since Leptanilla havilandi Forel, 1901 and represents the fourth species of Leptanilla known from the Malay Peninsula. An updated key to the Leptanilla of the Oriental region is presented. Taxonomic comparisons between Leptanilla hypodracos sp. n. and four morphologically similar species are provided with particular attention given to Leptanilla clypeata Yamane & Ito, 2001, for which new measurements and indices are presented. The first report is presented for the Leptanillinae subfamily from the southeastern part of China with a worker of the genus Leptanilla collected in Hong Kong. Finally, the potential of subterranean bait to collect Leptanilla species is discussed. PMID:26877667

  14. Experimental measurement-device-independent quantum key distribution with uncharacterized encoding.

    PubMed

    Wang, Chao; Wang, Shuang; Yin, Zhen-Qiang; Chen, Wei; Li, Hong-Wei; Zhang, Chun-Mei; Ding, Yu-Yang; Guo, Guang-Can; Han, Zheng-Fu

    2016-12-01

    Measurement-device-independent quantum key distribution (MDI QKD) is an efficient way to share secrets using untrusted measurement devices. However, the assumption on the characterizations of encoding states is still necessary in this promising protocol, which may lead to unnecessary complexity and potential loopholes in realistic implementations. Here, by using the mismatched-basis statistics, we present the first proof-of-principle experiment of MDI QKD with uncharacterized encoding sources. In this demonstration, the encoded states are only required to be constrained in a two-dimensional Hilbert space, and two distant parties (Alice and Bob) are resistant to state preparation flaws even if they have no idea about the detailed information of their encoding states. The positive final secure key rates of our system exhibit the feasibility of this novel protocol, and demonstrate its value for the application of secure communication with uncharacterized devices.

  15. Centralized Cryptographic Key Management and Critical Risk Assessment - CRADA Final Report For CRADA Number NFE-11-03562

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abercrombie, R. K.; Peters, Scott

    The Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) Cyber Security for Energy Delivery Systems (CSEDS) industry led program (DE-FOA-0000359) entitled "Innovation for Increasing Cyber Security for Energy Delivery Systems (12CSEDS)," awarded a contract to Sypris Electronics LLC to develop a Cryptographic Key Management System for the smart grid (Scalable Key Management Solutions for Critical Infrastructure Protection). Oak Ridge National Laboratory (ORNL) and Sypris Electronics, LLC as a result of that award entered into a CRADA (NFE-11-03562) between ORNL and Sypris Electronics, LLC. ORNL provided its Cyber Security Econometrics System (CSES) as a tool to be modifiedmore » and used as a metric to address risks and vulnerabilities in the management of cryptographic keys within the Advanced Metering Infrastructure (AMI) domain of the electric sector. ORNL concentrated our analysis on the AMI domain of which the National Electric Sector Cyber security Organization Resource (NESCOR) Working Group 1 (WG1) has documented 29 failure scenarios. The computational infrastructure of this metric involves system stakeholders, security requirements, system components and security threats. To compute this metric, we estimated the stakes that each stakeholder associates with each security requirement, as well as stochastic matrices that represent the probability of a threat to cause a component failure and the probability of a component failure to cause a security requirement violation. We applied this model to estimate the security of the AMI, by leveraging the recently established National Institute of Standards and Technology Interagency Report (NISTIR) 7628 guidelines for smart grid security and the International Electrotechnical Commission (IEC) 63351, Part 9 to identify the life cycle for cryptographic key management, resulting in a vector that assigned to each stakeholder an estimate of their average loss in terms of dollars per day of

  16. Optimizing prognosis-related key miRNA-target interactions responsible for cancer metastasis.

    PubMed

    Zhao, Hongying; Yuan, Huating; Hu, Jing; Xu, Chaohan; Liao, Gaoming; Yin, Wenkang; Xu, Liwen; Wang, Li; Zhang, Xinxin; Shi, Aiai; Li, Jing; Xiao, Yun

    2017-12-12

    Increasing evidence suggests that the abnormality of microRNAs (miRNAs) and their downstream targets is frequently implicated in the pathogenesis of human cancers, however, the clinical benefit of causal miRNA-target interactions has been seldom studied. Here, we proposed a computational method to optimize prognosis-related key miRNA-target interactions by combining transcriptome and clinical data from thousands of TCGA tumors across 16 cancer types. We obtained a total of 1,956 prognosis-related key miRNA-target interactions between 112 miRNAs and 1,443 their targets. Interestingly, these key target genes are specifically involved in tumor progression-related functions, such as 'cell adhesion' and 'cell migration'. Furthermore, they are most significantly correlated with 'tissue invasion and metastasis', a hallmark of metastasis, in ten distinct types of cancer through the hallmark analysis. These results implicated that the prognosis-related key miRNA-target interactions were highly associated with cancer metastasis. Finally, we observed that the combination of these key miRNA-target interactions allowed to distinguish patients with good prognosis from those with poor prognosis both in most TCGA cancer types and independent validation sets, highlighting their roles in cancer metastasis. We provided a user-friendly database named miRNATarget (freely available at http://biocc.hrbmu.edu.cn/miRNATar/), which provides an overview of the prognosis-related key miRNA-target interactions across 16 cancer types.

  17. International electives in the final year of German medical school education--a student's perspective.

    PubMed

    Ebrahimi-Fakhari, Darius; Agrawal, Mridul; Wahlster, Lara

    2014-01-01

    The final year of medical school has a unique role for introducing students to their future responsibilities and challenges. At many medical schools, electives at an accredited institution abroad are a common part of the student's final year experience. International electives provide an opportunity for a personal and academic experience that will often create new perspectives on clinical medicine and research, medical education and healthcare policy. In this article the authors reflect on their experience as elective students abroad and discuss the contribution of international electives to the constant development and progress of local final year rotations. They identify key areas for improving final year electives and outline essential features for a valuable and successful final year elective.

  18. Reducing school bus/light-vehicle conflicts through connected vehicle communications : final report.

    DOT National Transportation Integrated Search

    2016-09-15

    This project aimed to develop and test a concept for improving the safety of school bus transportation using connected vehicle technology. The project consisted of three key steps that led to a final road study: 1) conducting focus groups with light ...

  19. Physical similarity or numerical representation counts in same-different, numerical comparison, physical comparison, and priming tasks?

    PubMed

    Zhang, Li; Xin, Ziqiang; Feng, Tingyong; Chen, Yinghe; Szűcs, Denes

    2018-03-01

    Recent studies have highlighted the fact that some tasks used to study symbolic number representations are confounded by judgments about physical similarity. Here, we investigated whether the contribution of physical similarity and numerical representation differed in the often-used symbolic same-different, numerical comparison, physical comparison, and priming tasks. Experiment 1 showed that subjective physical similarity was the best predictor of participants' performance in the same-different task, regardless of simultaneous or sequential presentation. Furthermore, the contribution of subjective physical similarity was larger in a simultaneous presentation than in a sequential presentation. Experiment 2 showed that only numerical representation was involved in numerical comparison. Experiment 3 showed that both subjective physical similarity and numerical representation contributed to participants' physical comparison performance. Finally, only numerical representation contributed to participants' performance in a priming task as revealed by Experiment 4. Taken together, the contribution of physical similarity and numerical representation depends on task demands. Performance primarily seems to rely on numerical properties in tasks that require explicit quantitative comparison judgments (physical or numerical), while physical stimulus properties exert an effect in the same-different task.

  20. Key management of the double random-phase-encoding method using public-key encryption

    NASA Astrophysics Data System (ADS)

    Saini, Nirmala; Sinha, Aloka

    2010-03-01

    Public-key encryption has been used to encode the key of the encryption process. In the proposed technique, an input image has been encrypted by using the double random-phase-encoding method using extended fractional Fourier transform. The key of the encryption process have been encoded by using the Rivest-Shamir-Adelman (RSA) public-key encryption algorithm. The encoded key has then been transmitted to the receiver side along with the encrypted image. In the decryption process, first the encoded key has been decrypted using the secret key and then the encrypted image has been decrypted by using the retrieved key parameters. The proposed technique has advantage over double random-phase-encoding method because the problem associated with the transmission of the key has been eliminated by using public-key encryption. Computer simulation has been carried out to validate the proposed technique.

  1. Optical key system

    DOEpatents

    Hagans, Karla G.; Clough, Robert E.

    2000-01-01

    An optical key system comprises a battery-operated optical key and an isolated lock that derives both its operating power and unlock signals from the correct optical key. A light emitting diode or laser diode is included within the optical key and is connected to transmit a bit-serial password. The key user physically enters either the code-to-transmit directly, or an index to a pseudorandom number code, in the key. Such person identification numbers can be retained permanently, or ephemeral. When a send button is pressed, the key transmits a beam of light modulated with the password information. The modulated beam of light is received by a corresponding optical lock with a photovoltaic cell that produces enough power from the beam of light to operate a password-screen digital logic. In one application, an acceptable password allows a two watt power laser diode to pump ignition and timing information over a fiberoptic cable into a sealed engine compartment. The receipt of a good password allows the fuel pump, spark, and starter systems to each operate. Therefore, bypassing the lock mechanism as is now routine with automobile thieves is pointless because the engine is so thoroughly disabled.

  2. Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexander Fridman

    2005-06-01

    This DOE project DE-FC36-04GO14052 ''Plasma Pilot Plant Test for Treating VOC Emissions from Wood Products Plants'' was conducted by Drexel University in cooperation with Georgia-Pacific (G-P) and Kurchatov Institute (KI). The objective of this project was to test the Plasma Pilot Plant capabilities in wood industry. The final goal of the project was to replace the current state-of-the-art, regenerative thermal oxidation (RTO) technology by Low-Temperature Plasma Technology (LTPT) in paper and wood industry for Volatile Organic Components (VOC) destruction in High Volume Low Concentration (HVLC) vent emissions. MetPro Corporation joined the team as an industrial partner from the environmental controlmore » business and a potential leader for commercialization. Concurrent Technology Corporation (CTC) has a separate contract with DOE for this technology evaluation. They prepared questionnaires for comparison of this technology and RTO, and made this comparison. These data are presented in this report along with the description of the technology itself. Experiments with the pilot plant were performed with average plasma power up to 3.6 kW. Different design of the laboratory and pilot plant pulsed coronas, as well as different analytical methods revealed many new peculiarities of the VOC abatement process. The work reported herein describes the experimental results for the VOCs removal efficiency with respect to energy consumption, residence time, water effect and initial concentration.« less

  3. Security of Color Image Data Designed by Public-Key Cryptosystem Associated with 2D-DWT

    NASA Astrophysics Data System (ADS)

    Mishra, D. C.; Sharma, R. K.; Kumar, Manish; Kumar, Kuldeep

    2014-08-01

    In present times the security of image data is a major issue. So, we have proposed a novel technique for security of color image data by public-key cryptosystem or asymmetric cryptosystem. In this technique, we have developed security of color image data using RSA (Rivest-Shamir-Adleman) cryptosystem with two-dimensional discrete wavelet transform (2D-DWT). Earlier proposed schemes for security of color images designed on the basis of keys, but this approach provides security of color images with the help of keys and correct arrangement of RSA parameters. If the attacker knows about exact keys, but has no information of exact arrangement of RSA parameters, then the original information cannot be recovered from the encrypted data. Computer simulation based on standard example is critically examining the behavior of the proposed technique. Security analysis and a detailed comparison between earlier developed schemes for security of color images and proposed technique are also mentioned for the robustness of the cryptosystem.

  4. Alienation and Achievement Among Oglala Sioux Secondary School Students. Final Report.

    ERIC Educational Resources Information Center

    Spilka, Bernard

    As a final report on alienation and achievement among 753 Oglala Sioux secondary school students on the Pine Ridge Reservation, this document attempts to portray the circumstances affecting the Indian child in school. To provide a basis for comparison, the sample also contained 855 white secondary school pupils. General findings which are believed…

  5. Reinforcer Control by Comparison-Stimulus Color and Location in a Delayed Matching-to-Sample Task

    ERIC Educational Resources Information Center

    Alsop, Brent; Jones, B. Max

    2008-01-01

    Six pigeons were trained in a delayed matching-to-sample task involving bright- and dim-yellow samples on a central key, a five-peck response requirement to either sample, a constant 1.5-s delay, and the presentation of comparison stimuli composed of red on the left key and green on the right key or vice versa. Green-key responses were…

  6. Decoy-state quantum key distribution with polarized photons over 200 km.

    PubMed

    Liu, Yang; Chen, Teng-Yun; Wang, Jian; Cai, Wen-Qi; Wan, Xu; Chen, Luo-Kan; Wang, Jin-Hong; Liu, Shu-Bin; Liang, Hao; Yang, Lin; Peng, Cheng-Zhi; Chen, Kai; Chen, Zeng-Bing; Pan, Jian-Wei

    2010-04-12

    We report an implementation of decoy-state quantum key distribution (QKD) over 200 km optical fiber cable through photon polarization encoding. This is achieved by constructing the whole QKD system operating at 320 MHz repetition rate, and developing high-speed transmitter and receiver modules. A novel and economic way of synchronization method is designed and incorporated into the system, which allows to work at a low frequency of 40kHz and removes the use of highly precise clock. A final key rate of 15 Hz is distributed within the experimental time of 3089 seconds, by using super-conducting single photon detectors. This is longest decoy-state QKD yet demonstrated up to date. It helps to make a significant step towards practical secure communication in long-distance scope.

  7. Finite-key analysis for measurement-device-independent quantum key distribution.

    PubMed

    Curty, Marcos; Xu, Feihu; Cui, Wei; Lim, Charles Ci Wen; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2014-04-29

    Quantum key distribution promises unconditionally secure communications. However, as practical devices tend to deviate from their specifications, the security of some practical systems is no longer valid. In particular, an adversary can exploit imperfect detectors to learn a large part of the secret key, even though the security proof claims otherwise. Recently, a practical approach--measurement-device-independent quantum key distribution--has been proposed to solve this problem. However, so far its security has only been fully proven under the assumption that the legitimate users of the system have unlimited resources. Here we fill this gap and provide a rigorous security proof against general attacks in the finite-key regime. This is obtained by applying large deviation theory, specifically the Chernoff bound, to perform parameter estimation. For the first time we demonstrate the feasibility of long-distance implementations of measurement-device-independent quantum key distribution within a reasonable time frame of signal transmission.

  8. The final word. OSHA's final ruling offers firm deadlines for infection control.

    PubMed

    West, K

    1992-03-01

    Departments that have put off program development while waiting for the final ruling to be published have a lot of work to do. Many departments have been cited and fined by OSHA in the past year for failure to begin infection-control programs or provide hepatitis-B vaccines to personnel. Under the new budget, OSHA was granted permission to up its fine structure sevenfold--thus, a small fine is $7,000, and the highest fine for a single violation is $70,000. Fines can have a greater impact on a department's budget than implementation of the program over time. A key point to remember is that a strong infection-control program will reduce exposure follow-up costs and worker-compensation claims. Infection control is a win-win situation.

  9. Stability analysis of neural networks with time-varying delay: Enhanced stability criteria and conservatism comparisons

    NASA Astrophysics Data System (ADS)

    Lin, Wen-Juan; He, Yong; Zhang, Chuan-Ke; Wu, Min

    2018-01-01

    This paper is concerned with the stability analysis of neural networks with a time-varying delay. To assess system stability accurately, the conservatism reduction of stability criteria has attracted many efforts, among which estimating integral terms as exact as possible is a key issue. At first, this paper develops a new relaxed integral inequality to reduce the estimation gap of popular Wirtinger-based inequality (WBI). Then, for showing the advantages of the proposed inequality over several existing inequalities that also improve the WBI, four stability criteria are derived through different inequalities and the same Lyapunov-Krasovskii functional (LKF), and the conservatism comparison of them is analyzed theoretically. Moreover, an improved criterion is established by combining the proposed inequality and an augmented LKF with delay-product-type terms. Finally, several numerical examples are used to demonstrate the advantages of the proposed method.

  10. Free-space quantum key distribution at night

    NASA Astrophysics Data System (ADS)

    Buttler, William T.; Hughes, Richard J.; Kwiat, Paul G.; Lamoreaux, Steve K.; Luther, Gabriel G.; Morgan, George L.; Nordholt, Jane E.; Peterson, C. Glen; Simmons, Charles M.

    1998-07-01

    An experimental free-space quantum key distribution (QKD) system has been tested over an outdoor optical path of approximately 1 km under nighttime conditions at Los Alamos National Laboratory. This system employs the Bennett 92 protocol; here we give a brief overview of this protocol, and describe our experimental implementation of it. An analysis of the system efficiency is presented as well as a description of our error detection protocol, which employs a 2D parity check scheme. Finally, the susceptibility of this system to eavesdropping by various techniques is determined, and the effectiveness of privacy amplification procedures is discussed. Our conclusions are that free-space QKD is both effective and secure; possible applications include the rekeying of satellites in low earth orbit.

  11. Optical key system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagans, K.G.; Clough, R.E.

    2000-04-25

    An optical key system comprises a battery-operated optical key and an isolated lock that derives both its operating power and unlock signals from the correct optical key. A light emitting diode or laser diode is included within the optical key and is connected to transmit a bit-serial password. The key user physically enters either the code-to-transmit directly, or an index to a pseudorandom number code, in the key. Such person identification numbers can be retained permanently, or ephemeral. When a send button is pressed, the key transmits a beam of light modulated with the password information. The modulated beam ofmore » light is received by a corresponding optical lock with a photovoltaic cell that produces enough power from the beam of light to operate a password-screen digital logic. In one application, an acceptable password allows a two watt power laser diode to pump ignition and timing information over a fiberoptic cable into a sealed engine compartment. The receipt of a good password allows the fuel pump, spark, and starter systems to each operate. Therefore, bypassing the lock mechanism as is now routine with automobile thieves is pointless because the engine is so thoroughly disabled.« less

  12. Work Keys USA.

    ERIC Educational Resources Information Center

    Work Keys USA, 1998

    1998-01-01

    "Work Keys" is a comprehensive program for assessing and teaching workplace skills. This serial "special issue" features 18 first-hand reports on Work Keys projects in action in states across North America. They show how the Work Keys is helping businesses and educators solve the challenge of building a world-class work force.…

  13. Key Generation for Fast Inversion of the Paillier Encryption Function

    NASA Astrophysics Data System (ADS)

    Hirano, Takato; Tanaka, Keisuke

    We study fast inversion of the Paillier encryption function. Especially, we focus only on key generation, and do not modify the Paillier encryption function. We propose three key generation algorithms based on the speeding-up techniques for the RSA encryption function. By using our algorithms, the size of the private CRT exponent is half of that of Paillier-CRT. The first algorithm employs the extended Euclidean algorithm. The second algorithm employs factoring algorithms, and can construct the private CRT exponent with low Hamming weight. The third algorithm is a variant of the second one, and has some advantage such as compression of the private CRT exponent and no requirement for factoring algorithms. We also propose the settings of the parameters for these algorithms and analyze the security of the Paillier encryption function by these algorithms against known attacks. Finally, we give experimental results of our algorithms.

  14. A comparison of self-oscillating phonation models

    NASA Astrophysics Data System (ADS)

    McPhail, Michael; Campo, Elizabeth; Walters, Gage; Krane, Michael

    2017-11-01

    This talk presents a comparison of self-oscillating models of phonation. The goal is to assess how well synthetic rubber vocal folds reproduce the gross behavior of phonation. Data from molded rubber folds and a variety of excised mammalian larynges were collected from the literature and from the authors' physical model. Gross trends are discussed and a simple scaling is presented that appears to collapse these data. Finally, comparisons between molded rubber folds and excised larynges are highlighted. Acknowledge support from NIH DC R01005642-11.

  15. Finite key analysis for symmetric attacks in quantum key distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Tim; Kampermann, Hermann; Kleinmann, Matthias

    2006-10-15

    We introduce a constructive method to calculate the achievable secret key rate for a generic class of quantum key distribution protocols, when only a finite number n of signals is given. Our approach is applicable to all scenarios in which the quantum state shared by Alice and Bob is known. In particular, we consider the six state protocol with symmetric eavesdropping attacks, and show that for a small number of signals, i.e., below n{approx}10{sup 4}, the finite key rate differs significantly from the asymptotic value for n{yields}{infinity}. However, for larger n, a good approximation of the asymptotic value is found.more » We also study secret key rates for protocols using higher-dimensional quantum systems.« less

  16. Partially Key Distribution with Public Key Cryptosystem Based on Error Control Codes

    NASA Astrophysics Data System (ADS)

    Tavallaei, Saeed Ebadi; Falahati, Abolfazl

    Due to the low level of security in public key cryptosystems based on number theory, fundamental difficulties such as "key escrow" in Public Key Infrastructure (PKI) and a secure channel in ID-based cryptography, a new key distribution cryptosystem based on Error Control Codes (ECC) is proposed . This idea is done by some modification on McEliece cryptosystem. The security of ECC cryptosystem obtains from the NP-Completeness of block codes decoding. The capability of generating public keys with variable lengths which is suitable for different applications will be provided by using ECC. It seems that usage of these cryptosystems because of decreasing in the security of cryptosystems based on number theory and increasing the lengths of their keys would be unavoidable in future.

  17. International documentary standards and comparison of national physical measurement standards for the calibration of accelerometers

    NASA Astrophysics Data System (ADS)

    Evans, David J.

    2002-11-01

    The documentary standards defining internationally adopted methodologies and protocols for calibrating transducers used to measure vibration are currently developed under the International Organization for Standardization (ISO) Technical Committee 108 Sub Committee 3 (Use and calibration of vibration and shock measuring instruments). Recent revisions of the documentary standards on primary methods for the calibration of accelerometers used to measure rectilinear motion have been completed. These standards can be, and have been, used as references in the technical protocols of key international and regional comparisons between National Measurement Institutes (NMIs) on the calibration of accelerometers. These key comparisons are occurring in part as a result of the creation of the Mutual Recognition Arrangement between NMIs which has appendices that document the uncertainties, and the comparisons completed in support of the uncertainties, claimed by the National Laboratories that are signatories of the MRA. The measurements for the first international and the first Interamerican System of Metrology (SIM) regional key comparisons in vibration have been completed. These intercomparisons were promulgated via the relatively new Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM) and SIM Metrology Working Group (MWG) 9, respectively.

  18. Comparison of Oregon state highway division Table-1 and Table-2 asphalt : final report.

    DOT National Transportation Integrated Search

    1991-12-01

    The objective of this study was to compare the effect of using the Oregon State Highway Division (OSHD) modified Table-1 asphalts and the OSHD modified Table-2 asphalts in asphalt concrete; the primary factors for comparison were reflective and therm...

  19. Higher-order differential phase shift keyed modulation

    NASA Astrophysics Data System (ADS)

    Vanalphen, Deborah K.; Lindsey, William C.

    1994-02-01

    Advanced modulation/demodulation techniques which are robust in the presence of phase and frequency uncertainties continue to be of interest to communication engineers. We are particularly interested in techniques which accommodate slow channel phase and frequency variations with minimal performance degradation and which alleviate the need for phase and frequency tracking loops in the receiver. We investigate the performance sensitivity to frequency offsets of a modulation technique known as binary Double Differential Phase Shift Keying (DDPSK) and compare it to that of classical binary Differential Phase Shift Keying (DPSK). We also generalize our analytical results to include n(sup -th) order, M-ary DPSK. The DDPSK (n = 2) technique was first introduced in the Russian literature circa 1972 and was studied more thoroughly in the late 1970's by Pent and Okunev. Here, we present an expression for the symbol error probability that is easy to derive and to evaluate numerically. We also present graphical results that establish when, as a function of signal energy-to-noise ratio and normalized frequency offset, binary DDPSK is preferable to binary DPSK with respect to performance in additive white Gaussian noise. Finally, we provide insight into the optimum receiver from a detection theory viewpoint.

  20. Keys to Scholarship

    ERIC Educational Resources Information Center

    Hebert, Terri

    2011-01-01

    Up ahead, a foreboding wooden door showing wear from passage of earlier travelers is spotted. As the old porch light emits a pale yellow glow, a key ring emerges from deep inside the coat pocket. Searching for just the right key, the voyager settles on one that also shows age. As the key enters its receptacle and begins to turn, a clicking noise…

  1. Key Recommendations from the MedtecHTA Project.

    PubMed

    Tarricone, Rosanna; Torbica, Aleksandra; Drummond, Michael

    2017-02-01

    There are particular characteristics of Medical Devices, such as the device-user interaction, the incremental nature of innovation and the broader organizational impact that lead to additional challenges for health technology assessment (HTA). The project explored key aspects of the conduct and methods of HTA for MDs. Systematic reviews and original research studies were conducted to determine improvements in processes and methods that could enhance the potential for HTA and optimize the diffusion of MDs. Regulatory processes for MDs should be more closely aligned, the HTA evaluative framework should be harmonized and processes for conditional coverage and evidence development should be used. The methods for HTA should consider MDs as complex interventions, require the establishment of high quality registries, consider an iterative approach to the evaluation over time, recognize and allow for the particular characteristics of devices and use appropriate approaches for confounder adjustment in comparative effectiveness studies. To optimize the diffusion, a common classification should be developed across countries in order to facilitate international comparisons, factors driving diffusion should be explored in HTA reports and physicians' personal goals and motivation should be better understood. The key recommendations of the MedtecHTA project should improve the conduct and use of HTA for MDs. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd.

  2. Creation of Audiovisual Presentations as a Tool to Develop Key Competences in Secondary-School Students. A Case Study in Science Class

    ERIC Educational Resources Information Center

    Ezquerra, Ángel; Manso, Javier; Burgos, Mª Esther; Hallabrin, Carla

    2014-01-01

    New curricular plans based on key competences create the need for new educational proposals that allow their development. This article describes a proposal to develop key competences through project-based learning. The project's objective is the creation of a digital video. The following study was carried out with students in their final two years…

  3. Graphical Arrays of Chemical-Specific Health Effect Reference Values for Inhalation Exposures (2009 Final Report)

    EPA Science Inventory

    This document provides graphical arrays and tables of key information on the derivation of human inhalation health effect reference values for specific chemicals, allowing comparisons across durations, populations, and intended use. A number of program offices within the Agency, ...

  4. Automated secured cost effective key refreshing technique to enhance WiMAX privacy key management

    NASA Astrophysics Data System (ADS)

    Sridevi, B.; Sivaranjani, S.; Rajaram, S.

    2013-01-01

    In all walks of life the way of communication is transformed by the rapid growth of wireless communication and its pervasive use. A wireless network which is fixed and richer in bandwidth is specified as IEEE 802.16, promoted and launched by an industrial forum is termed as Worldwide Interoperability for Microwave Access (WiMAX). This technology enables seamless delivery of wireless broadband service for fixed and/or mobile users. The obscurity is the long delay which occurs during the handoff management in every network. Mobile WiMAX employs an authenticated key management protocol as a part of handoff management in which the Base Station (BS) controls the distribution of keying material to the Mobile Station (MS). The protocol employed is Privacy Key Management Version 2- Extensible Authentication Protocol (PKMV2-EAP) which is responsible for the normal and periodical authorization of MSs, reauthorization as well as key refreshing. Authorization key (AK) and Traffic Encryption key (TEK) plays a vital role in key exchange. When the lifetime of key expires, MS has to request for a new key to BS which in turn leads to repetition of authorization, authentication as well as key exchange. To avoid service interruption during reauthorization , two active keys are transmitted at the same time by BS to MS. The consequences of existing work are hefty amount of bandwidth utilization, time consumption and large storage. It is also endured by Man in the Middle attack and Impersonation due to lack of security in key exchange. This paper designs an automatic mutual refreshing of keys to minimize bandwidth utilization, key storage and time consumption by proposing Previous key and Iteration based Key Refreshing Function (PKIBKRF). By integrating PKIBKRF in key generation, the simulation results indicate that 21.8% of the bandwidth and storage of keys are reduced and PKMV2 mutual authentication time is reduced by 66.67%. The proposed work is simulated with Qualnet model and

  5. Quantum hacking of two-way continuous-variable quantum key distribution using Trojan-horse attack

    NASA Astrophysics Data System (ADS)

    Ma, Hong-Xin; Bao, Wan-Su; Li, Hong-Wei; Chou, Chun

    2016-08-01

    We present a Trojan-horse attack on the practical two-way continuous-variable quantum key distribution system. Our attack mainly focuses on the imperfection of the practical system that the modulator has a redundancy of modulation pulse-width, which leaves a loophole for the eavesdropper inserting a Trojan-horse pulse. Utilizing the unique characteristics of two-way continuous-variable quantum key distribution that Alice only takes modulation operation on the received mode without any measurement, this attack allows the eavesdropper to render all of the final keys shared between the legitimate parties insecure without being detected. After analyzing the feasibility of the attack, the corresponding countermeasures are put forward. Project supported by the National Basic Research Program of China (Grant No. 2013CB338002) and the National Natural Science Foundation of China (Grant Nos. 11304397 and 61505261).

  6. Timing the Mode Switch in a Sequential Mixed-Mode Survey: An Experimental Evaluation of the Impact on Final Response Rates, Key Estimates, and Costs

    PubMed Central

    Wagner, James; Schroeder, Heather M.; Piskorowski, Andrew; Ursano, Robert J.; Stein, Murray B.; Heeringa, Steven G.; Colpe, Lisa J.

    2017-01-01

    Mixed-mode surveys need to determine a number of design parameters that may have a strong influence on costs and errors. In a sequential mixed-mode design with web followed by telephone, one of these decisions is when to switch modes. The web mode is relatively inexpensive but produces lower response rates. The telephone mode complements the web mode in that it is relatively expensive but produces higher response rates. Among the potential negative consequences, delaying the switch from web to telephone may lead to lower response rates if the effectiveness of the prenotification contact materials is reduced by longer time lags, or if the additional e-mail reminders to complete the web survey annoy the sampled person. On the positive side, delaying the switch may decrease the costs of the survey. We evaluate these costs and errors by experimentally testing four different timings (1, 2, 3, or 4 weeks) for the mode switch in a web–telephone survey. This experiment was conducted on the fourth wave of a longitudinal study of the mental health of soldiers in the U.S. Army. We find that the different timings of the switch in the range of 1–4 weeks do not produce differences in final response rates or key estimates but longer delays before switching do lead to lower costs. PMID:28943717

  7. Operating Reserves and Wind Power Integration: An International Comparison; Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milligan, M.; Donohoo, P.; Lew, D.

    2010-10-01

    This paper provides a high-level international comparison of methods and key results from both operating practice and integration analysis, based on an informal International Energy Agency Task 25: Large-scale Wind Integration.

  8. Key issues in space nuclear power

    NASA Technical Reports Server (NTRS)

    Brandhorst, Henry W.

    1991-01-01

    The future appears rich in missions that will extend the frontiers of knowledge, human presence in space, and opportunities for profitable commerce. Key to the success of these ventures is the availability of plentiful, cost effective electric power and assured, low cost access to space. While forecasts of space power needs are problematic, an assessment of future needs based on terrestrial experience has been made. These needs fall into three broad categories: survival, self sufficiency, and industrialization. The cost of delivering payloads to orbital locations from LEO to Mars has been determined and future launch cost reductions projected. From these factors, then, projections of the performance necessary for future solar and nuclear space power options has been made. These goals are largely dependent upon orbital location and energy storage needs. Finally the cost of present space power systems has been determined and projections made for future systems.

  9. Waking the health plan giant: Group Health Cooperative stops counting sheep and starts counting key tobacco indicators.

    PubMed

    McAfee, T

    1998-01-01

    Implementing a comprehensive approach to decreasing tobacco use in a large health plan requires hard work and commitment on the part of many individuals. We found that major organisational change can be accomplished and sustained. Keys to our success included our decision to remove access barriers to our cessation programmes (including cost); obtaining top leadership buy-in; identifying accountable individuals who owned responsibility for change; measuring key processes and outcomes; and finally keeping at it tenaciously through multiple cycles of improvement.

  10. Economic comparison between conventional and disposables-based technology for the production of biopharmaceuticals.

    PubMed

    Novais, J L; Titchener-Hooker, N J; Hoare, M

    2001-10-20

    Time to market, cost effectiveness, and flexibility are key issues in today's biopharmaceutical market. Bioprocessing plants based on fully disposable, presterilized, and prevalidated components appear as an attractive alternative to conventional stainless steel plants, potentially allowing for shorter implementation times, smaller initial investments, and increased flexibility. To evaluate the economic case of such an alternative it was necessary to develop an appropriate costing model which allows an economic comparison between conventional and disposables-based engineering to be made. The production of an antibody fragment from an E. coli fermentation was used to provide a case study for both routes. The conventional bioprocessing option was costed through available models, which were then modified to account for the intrinsic differences observed in a disposables-based option. The outcome of the analysis indicates that the capital investment required for a disposables-based option is substantially reduced at less than 60% of that for a conventional option. The disposables-based running costs were evaluated as being 70% higher than those of the conventional equivalent. Despite this higher value, the net present value (NPV) of the disposables-based plant is positive and within 25% of that for the conventional plant. Sensitivity analysis performed on key variables indicated the robustness of the economic analysis presented. In particular a 9-month reduction in time to market arising from the adoption of a disposables-based approach, results in a NPV which is identical to that of the conventional option. Finally, the effect of any possible loss in yield resulting from the use of disposables was also examined. This had only a limited impact on the NPV: for example, a 50% lower yield in the disposable chromatography step results in a 10% reduction of the disposable NPV. The results provide the necessary framework for the economic comparison of disposables and

  11. Key issues in the quality assurance of the One Number Census.

    PubMed

    Diamond, Ian; Abbott, Owen; Jackson, Neil

    2003-01-01

    As part of the 2001 Census, the One Number Census project estimated and adjusted the Census database for underenumeration. As a result of the highly innovative One Number Census and the Quality Assurance process it encompassed, it was also ensured that robust results could be obtained for each local authority area. This article examines some of the issues and analyses that were undertaken as part of that assessment of the 2001 Census population counts for England and Wales. The article firstly highlights the key issues surrounding the implementation of the 2001 Census fieldwork. The article then explores the 2001 Census results through a series of demographic analyses to illustrate the sorts of issues investigated during the One Number Census Quality Assurance process itself. These analyses look at the patterns contained within the results, and comparisons with key alternative sources of population counts. Overall, these in-depth analyses and investigations provide further credence to the plausibility of the One Number Census results.

  12. Entangled-coherent-state quantum key distribution with entanglement witnessing

    NASA Astrophysics Data System (ADS)

    Simon, David S.; Jaeger, Gregg; Sergienko, Alexander V.

    2014-01-01

    An entanglement-witness approach to quantum coherent-state key distribution and a system for its practical implementation are described. In this approach, eavesdropping can be detected by a change in sign of either of two witness functions: an entanglement witness S or an eavesdropping witness W. The effects of loss and eavesdropping on system operation are evaluated as a function of distance. Although the eavesdropping witness W does not directly witness entanglement for the system, its behavior remains related to that of the true entanglement witness S. Furthermore, W is easier to implement experimentally than S. W crosses the axis at a finite distance, in a manner reminiscent of entanglement sudden death. The distance at which this occurs changes measurably when an eavesdropper is present. The distance dependence of the two witnesses due to amplitude reduction and due to increased variance resulting from both ordinary propagation losses and possible eavesdropping activity is provided. Finally, the information content and secure key rate of a continuous variable protocol using this witness approach are given.

  13. Personal Self and Collective Self: When Academic Choices Depend on the Context of Social Comparison

    ERIC Educational Resources Information Center

    Chazal, Sebastien; Guimond, Serge; Darnon, Celine

    2012-01-01

    This research examines the impact of same-sex versus opposite-sex social comparisons on the perception of one's own abilities at school and subsequent reported marks and academic choices. During their final year, male and female high school students were asked to describe themselves either in comparison with boys in their class, in comparison with…

  14. Sarma-based key-group method for rock slope reliability analyses

    NASA Astrophysics Data System (ADS)

    Yarahmadi Bafghi, A. R.; Verdel, T.

    2005-08-01

    The methods used in conducting static stability analyses have remained pertinent to this day for reasons of both simplicity and speed of execution. The most well-known of these methods for purposes of stability analysis of fractured rock masses is the key-block method (KBM).This paper proposes an extension to the KBM, called the key-group method (KGM), which combines not only individual key-blocks but also groups of collapsable blocks into an iterative and progressive analysis of the stability of discontinuous rock slopes. To take intra-group forces into account, the Sarma method has been implemented within the KGM in order to generate a Sarma-based KGM, abbreviated SKGM. We will discuss herein the hypothesis behind this new method, details regarding its implementation, and validation through comparison with results obtained from the distinct element method.Furthermore, as an alternative to deterministic methods, reliability analyses or probabilistic analyses have been proposed to take account of the uncertainty in analytical parameters and models. The FOSM and ASM probabilistic methods could be implemented within the KGM and SKGM framework in order to take account of the uncertainty due to physical and mechanical data (density, cohesion and angle of friction). We will then show how such reliability analyses can be introduced into SKGM to give rise to the probabilistic SKGM (PSKGM) and how it can be used for rock slope reliability analyses. Copyright

  15. Round-robin differential-phase-shift quantum key distribution with heralded pair-coherent sources

    NASA Astrophysics Data System (ADS)

    Wang, Le; Zhao, Shengmei

    2017-04-01

    Round-robin differential-phase-shift (RRDPS) quantum key distribution (QKD) scheme provides an effective way to overcome the signal disturbance from the transmission process. However, most RRDPS-QKD schemes use weak coherent pulses (WCPs) as the replacement of the perfect single-photon source. Considering the heralded pair-coherent source (HPCS) can efficiently remove the shortcomings of WCPs, we propose a RRDPS-QKD scheme with HPCS in this paper. Both infinite-intensity decoy-state method and practical three-intensity decoy-state method are adopted to discuss the tight bound of the key rate of the proposed scheme. The results show that HPCS is a better candidate for the replacement of the perfect single-photon source, and both the key rate and the transmission distance are greatly increased in comparison with those results with WCPs when the length of the pulse trains is small. Simultaneously, the performance of the proposed scheme using three-intensity decoy states is close to that result using infinite-intensity decoy states when the length of pulse trains is small.

  16. Electric chiller handbook. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-02-01

    Electric chillers have dominated the market for large commercial cooling systems due to their history of reliable, economical operation. The phaseout of CFCs and deregulation of the utility industry are two factors that significantly impact the chiller market. The CFC phaseout is resulting in the upgrading or replacement of thousands of electric chillers nationwide. In a deregulated environment, utilities are finding increasing need to provide services that can win and retain new customers. Utility representatives need current information on applying and selecting cost-effective chiller systems. The objective of this report was to develop a comprehensive handbook that helps utility technicalmore » and marketing staff, their customers, and design professionals evaluate and select the best options for chilled-water systems in commercial buildings. Investigators used a variety of industry data sources to develop market-share information for electric and gas chiller systems and to determine applications according to building age, type, and region. Discussions with chiller manufacturers provided information on product availability, performance, and ownership cost. Using EPRI`s COMTECH software, investigators performed comprehensive cost analyses for placement of large and small chillers in three representative cities. Case studies of actual installations support these analyses. Electric Chiller Handbook provides a single source of current information on all major issues associated with chiller selection and application. Key issues include chiller availability and markets, rated performance, future viability of various refrigerant options, the cost-effectiveness of alternative chillers, and chilled-water system optimization. The Handbook also describes available hardware, outlines the features and costs of gas-fired competitive systems, and provides methods and comparisons of life-cycle costing of various chiller system options. Analyses of chiller features and

  17. Improved key-rate bounds for practical decoy-state quantum-key-distribution systems

    NASA Astrophysics Data System (ADS)

    Zhang, Zhen; Zhao, Qi; Razavi, Mohsen; Ma, Xiongfeng

    2017-01-01

    The decoy-state scheme is the most widely implemented quantum-key-distribution protocol in practice. In order to account for the finite-size key effects on the achievable secret key generation rate, a rigorous statistical fluctuation analysis is required. Originally, a heuristic Gaussian-approximation technique was used for this purpose, which, despite its analytical convenience, was not sufficiently rigorous. The fluctuation analysis has recently been made rigorous by using the Chernoff bound. There is a considerable gap, however, between the key-rate bounds obtained from these techniques and that obtained from the Gaussian assumption. Here we develop a tighter bound for the decoy-state method, which yields a smaller failure probability. This improvement results in a higher key rate and increases the maximum distance over which secure key exchange is possible. By optimizing the system parameters, our simulation results show that our method almost closes the gap between the two previously proposed techniques and achieves a performance similar to that of conventional Gaussian approximations.

  18. Group assessment of key indicators of sustainable waste management in developing countries.

    PubMed

    Tot, Bojana; Vujić, Goran; Srđević, Zorica; Ubavin, Dejan; Russo, Mário Augusto Tavares

    2017-09-01

    Decision makers in developing countries are struggling to solve the present problems of solid waste management. Prioritisation and ranking of the most important indicators that influence the waste management system is very useful for any decision maker for the future planning and implementation of a sustainable waste management system. The aim of this study is to evaluate key indicators and their related sub-indicators in a group decision-making environment. In order to gain insight into the subject it was necessary to obtain the qualified opinions of decision makers from different countries who understand the situation in the sector of waste management in developing countries. An assessment is performed by 43 decision makers from both developed and developing countries, and the applied methodology is based on a combined use of the analytic hierarchy process, from the multi-criteria decision-making set of tools, and the preferential voting method known as Borda Count, which belongs to social choice theory. Pairwise comparison of indicators is performed with the analytic hierarchy process, and the ranking of indicators once obtained is assessed with Borda Count. Detailed analysis of the final results showed that the Institutional-Administrative indicator was the most important one, with the maximum weight as derived by both groups of decision makers. The results also showed that the combined use of the analytic hierarchy process and Borda Count contributes to the credibility and objectivity of the decision-making process, allowing its use in more complex waste management group decision-making problems to be recommended.

  19. The shaping-lathe headrig-- key to utilization of hardwoods growing on southern pine sites

    Treesearch

    P. Koch

    1974-01-01

    For every cubic foot of pine on southern pine sites, there is about 0.8 cubic foot of hardwood. The shaping-lathe headrig, now in the final stages of commercialization, is a key to utilizing these small mixed hardwoods for pallets and industrial lumber. Lathe residues in the form of flakes can be the raw material for a new major industry manufacturing exterior...

  20. The psychological costs of comparisons: Parents' social comparison moderates the links between family management of epilepsy and children's outcomes.

    PubMed

    Mendes, Teresa P; Crespo, Carla A; Austin, Joan K

    2017-10-01

    Parents play a key role in how children deal with epilepsy. When diagnosed with health conditions, people seek comparison information from fellow patients and families, and this information has consequences for how they evaluate their situation. This study examined the moderating role of parents' social comparison orientation in the associations between family management (parental perceptions of family life difficulties and child's daily life) and adaptation outcomes of children with epilepsy (HRQoL and perceived stigma). Participants included 201 dyads of children with epilepsy and either their mother or father. The results showed that when parents perceived higher difficulties managing their child's epilepsy and/or reported that their child was more affected by this condition, children reported higher perceived stigma and worse HRQoL only when parents had a higher social comparison orientation. Our results are innovative in showing that when parents have a higher social comparison orientation, their children may be at increased risk of poorer outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. A Technical, User and Cost Comparison Study of Microfiche Duplicate Film Material. Final Report.

    ERIC Educational Resources Information Center

    Prevel, James J.

    A technical, user and cost comparison study was undertaken to provide the Educational Resources Information Clearinghouse (ERIC) staff with data on silver halide, diazo, and vesicular type films for microfiche duplication. This information will allow ERIC to determine if diazo and/or vesicular films should be considered in producing ERIC duplicate…

  2. Statistics attack on `quantum private comparison with a malicious third party' and its improvement

    NASA Astrophysics Data System (ADS)

    Gu, Jun; Ho, Chih-Yung; Hwang, Tzonelih

    2018-02-01

    Recently, Sun et al. (Quantum Inf Process:14:2125-2133, 2015) proposed a quantum private comparison protocol allowing two participants to compare the equality of their secrets via a malicious third party (TP). They designed an interesting trap comparison method to prevent the TP from knowing the final comparison result. However, this study shows that the malicious TP can use the statistics attack to reveal the comparison result. A simple modification is hence proposed to solve this problem.

  3. Identification and comparison of aberrant key regulatory networks in breast, colon, liver, lung, and stomach cancers through methylome database analysis.

    PubMed

    Kim, Byungtak; Kang, Seongeun; Jeong, Gookjoo; Park, Sung-Bin; Kim, Sun Jung

    2014-01-01

    Aberrant methylation of specific CpG sites at the promoter is widely responsible for genesis and development of various cancer types. Even though the microarray-based methylome analyzing techniques have contributed to the elucidation of the methylation change at the genome-wide level, the identification of key methylation markers or top regulatory networks appearing common in highly incident cancers through comparison analysis is still limited. In this study, we in silico performed the genome-wide methylation analysis on each 10 sets of normal and cancer pairs of five tissues: breast, colon, liver, lung, and stomach. The methylation array covers 27,578 CpG sites, corresponding to 14,495 genes, and significantly hypermethylated or hypomethylated genes in the cancer were collected (FDR adjusted p-value <0.05; methylation difference >0.3). Analysis of the dataset confirmed the methylation of previously known methylation markers and further identified novel methylation markers, such as GPX2, CLDN15, and KL. Cluster analysis using the methylome dataset resulted in a diagram with a bipartite mode distinguishing cancer cells from normal cells regardless of tissue types. The analysis further revealed that breast cancer was closest with lung cancer, whereas it was farthest from colon cancer. Pathway analysis identified that either the "cancer" related network or the "cancer" related bio-function appeared as the highest confidence in all the five cancers, whereas each cancer type represents its tissue-specific gene sets. Our results contribute toward understanding the essential abnormal epigenetic pathways involved in carcinogenesis. Further, the novel methylation markers could be applied to establish markers for cancer prognosis.

  4. Metrics for comparison of crystallographic maps

    DOE PAGES

    Urzhumtsev, Alexandre; Afonine, Pavel V.; Lunin, Vladimir Y.; ...

    2014-10-01

    Numerical comparison of crystallographic contour maps is used extensively in structure solution and model refinement, analysis and validation. However, traditional metrics such as the map correlation coefficient (map CC, real-space CC or RSCC) sometimes contradict the results of visual assessment of the corresponding maps. This article explains such apparent contradictions and suggests new metrics and tools to compare crystallographic contour maps. The key to the new methods is rank scaling of the Fourier syntheses. The new metrics are complementary to the usual map CC and can be more helpful in map comparison, in particular when only some of their aspects,more » such as regions of high density, are of interest.« less

  5. Morphological Comparison of U3O8 Ore Concentrates from Canada Key Lake and Namibia Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, Daniel S.; Tandon, Lav; Martinez, Patrick Thomas

    Uranium ore concentrates from two different sources were examined using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The ore powders are referred to as Namibia (id. no. 90036, LIMS id. no. 18775) and Canada Key Lake (id. no. 90019, LIMS id. no. 18774). Earlier work identified the ores as the U₃O₈ phase of uranium oxide using x-ray diffraction. Both sets of powders were in the form of dark brown to black powder fines. However, the Canada Key Lake concentrates contained larger chunks of material on the millimeter scale that were easily visible to the unaided eye. The powdersmore » were mounted for SEM examination by hand dispersing a small amount onto conductive sticky tape. Two types of applicators were used and compared: a fine-tipped spatula and a foam-tipped applicator. The sticky tape was on a standard SEM “tee” mount, which was tapped to remove loose contamination before being inserted into the SEM.« less

  6. A Key Pre-Distribution Scheme Based on µ-PBIBD for Enhancing Resilience in Wireless Sensor Networks.

    PubMed

    Yuan, Qi; Ma, Chunguang; Yu, Haitao; Bian, Xuefen

    2018-05-12

    Many key pre-distribution (KPD) schemes based on combinatorial design were proposed for secure communication of wireless sensor networks (WSNs). Due to complexity of constructing the combinatorial design, it is infeasible to generate key rings using the corresponding combinatorial design in large scale deployment of WSNs. In this paper, we present a definition of new combinatorial design, termed “µ-partially balanced incomplete block design (µ-PBIBD)”, which is a refinement of partially balanced incomplete block design (PBIBD), and then describe a 2-D construction of µ-PBIBD which is mapped to KPD in WSNs. Our approach is of simple construction which provides a strong key connectivity and a poor network resilience. To improve the network resilience of KPD based on 2-D µ-PBIBD, we propose a KPD scheme based on 3-D Ex-µ-PBIBD which is a construction of µ-PBIBD from 2-D space to 3-D space. Ex-µ-PBIBD KPD scheme improves network scalability and resilience while has better key connectivity. Theoretical analysis and comparison with the related schemes show that key pre-distribution scheme based on Ex-µ-PBIBD provides high network resilience and better key scalability, while it achieves a trade-off between network resilience and network connectivity.

  7. A Key Pre-Distribution Scheme Based on µ-PBIBD for Enhancing Resilience in Wireless Sensor Networks

    PubMed Central

    Yuan, Qi; Ma, Chunguang; Yu, Haitao; Bian, Xuefen

    2018-01-01

    Many key pre-distribution (KPD) schemes based on combinatorial design were proposed for secure communication of wireless sensor networks (WSNs). Due to complexity of constructing the combinatorial design, it is infeasible to generate key rings using the corresponding combinatorial design in large scale deployment of WSNs. In this paper, we present a definition of new combinatorial design, termed “µ-partially balanced incomplete block design (µ-PBIBD)”, which is a refinement of partially balanced incomplete block design (PBIBD), and then describe a 2-D construction of µ-PBIBD which is mapped to KPD in WSNs. Our approach is of simple construction which provides a strong key connectivity and a poor network resilience. To improve the network resilience of KPD based on 2-D µ-PBIBD, we propose a KPD scheme based on 3-D Ex-µ-PBIBD which is a construction of µ-PBIBD from 2-D space to 3-D space. Ex-µ-PBIBD KPD scheme improves network scalability and resilience while has better key connectivity. Theoretical analysis and comparison with the related schemes show that key pre-distribution scheme based on Ex-µ-PBIBD provides high network resilience and better key scalability, while it achieves a trade-off between network resilience and network connectivity. PMID:29757244

  8. Public Key Cryptography.

    ERIC Educational Resources Information Center

    Tapson, Frank

    1996-01-01

    Describes public key cryptography, also known as RSA, which is a system using two keys, one used to put a message into cipher and another used to decipher the message. Presents examples using small prime numbers. (MKR)

  9. A Round-Efficient Authenticated Key Agreement Scheme Based on Extended Chaotic Maps for Group Cloud Meeting.

    PubMed

    Lin, Tsung-Hung; Tsung, Chen-Kun; Lee, Tian-Fu; Wang, Zeng-Bo

    2017-12-03

    The security is a critical issue for business purposes. For example, the cloud meeting must consider strong security to maintain the communication privacy. Considering the scenario with cloud meeting, we apply extended chaotic map to present passwordless group authentication key agreement, termed as Passwordless Group Authentication Key Agreement (PL-GAKA). PL-GAKA improves the computation efficiency for the simple group password-based authenticated key agreement (SGPAKE) proposed by Lee et al. in terms of computing the session key. Since the extended chaotic map has equivalent security level to the Diffie-Hellman key exchange scheme applied by SGPAKE, the security of PL-GAKA is not sacrificed when improving the computation efficiency. Moreover, PL-GAKA is a passwordless scheme, so the password maintenance is not necessary. Short-term authentication is considered, hence the communication security is stronger than other protocols by dynamically generating session key in each cloud meeting. In our analysis, we first prove that each meeting member can get the correct information during the meeting. We analyze common security issues for the proposed PL-GAKA in terms of session key security, mutual authentication, perfect forward security, and data integrity. Moreover, we also demonstrate that communicating in PL-GAKA is secure when suffering replay attacks, impersonation attacks, privileged insider attacks, and stolen-verifier attacks. Eventually, an overall comparison is given to show the performance between PL-GAKA, SGPAKE and related solutions.

  10. Incompleteness and limit of security theory of quantum key distribution

    NASA Astrophysics Data System (ADS)

    Hirota, Osamu; Murakami, Dan; Kato, Kentaro; Futami, Fumio

    2012-10-01

    It is claimed in the many papers that a trace distance: d guarantees the universal composition security in quantum key distribution (QKD) like BB84 protocol. In this introduction paper, at first, it is explicitly explained what is the main misconception in the claim of the unconditional security for QKD theory. In general terms, the cause of the misunderstanding on the security claim is the Lemma in the paper of Renner. It suggests that the generation of the perfect random key is assured by the probability (1-d), and its failure probability is d. Thus, it concludes that the generated key provides the perfect random key sequence when the protocol is success. So the QKD provides perfect secrecy to the one time pad. This is the reason for the composition claim. However, the quantity of the trace distance (or variational distance) is not the probability for such an event. If d is not small enough, always the generated key sequence is not uniform. Now one needs the reconstruction of the evaluation of the trace distance if one wants to use it. One should first go back to the indistinguishability theory in the computational complexity based, and to clarify the meaning of the value of the variational distance. In addition, the same analysis for the information theoretic case is necessary. The recent serial papers by H.P.Yuen have given the answer on such questions. In this paper, we show more concise description of Yuen's theory, and clarify that the upper bound theories for the trace distance by Tomamichel et al and Hayashi et al are constructed by the wrong reasoning of Renner and it is unsuitable as the security analysis. Finally, we introduce a new macroscopic quantum communication to replace Q-bit QKD.

  11. Comparison Between Laser Scanning and Automated 3d Modelling Techniques to Reconstruct Complex and Extensive Cultural Heritage Areas

    NASA Astrophysics Data System (ADS)

    Fassi, F.; Fregonese, L.; Ackermann, S.; De Troia, V.

    2013-02-01

    In Cultural Heritage field, the necessity to survey objects in a fast manner, with the ability to repeat the measurements several times for deformation or degradation monitoring purposes, is increasing. In this paper, two significant cases, an architectonical one and an archaeological one, are presented. Due to different reasons and emergency situations, the finding of the optimal solution to enable quick and well-timed survey for a complete digital reconstruction of the object is required. In both cases, two survey methods have been tested and used: a laser scanning approach that allows to obtain high-resolution and complete scans within a short time and a photogrammetric one that allows the three-dimensional reconstruction of the object from images. In the last months, several methodologies, including free or low cost techniques, have arisen. These kinds of software allow the fully automatically three-dimensional reconstruction of objects from images, giving back a dense point cloud and, in some case, a surfaced mesh model. In this paper some comparisons between the two methodologies above mentioned are presented, using the example of some real cases of study. The surveys have been performed by employing both photogrammetry and laser scanner techniques. The methodological operational choices, depending on the required goal, the difficulties encountered during the survey with these methods, the execution time (that is the key parameter), and finally the obtained results, are fully described and examinated. On the final 3D model, an analytical comparison has been made, to analyse the differences, the tolerances, the possibility of accuracy improvement and the future developments.

  12. Behind the Final Grade in Hybrid v. Traditional Courses: Comparing Student Performance by Assessment Type, Core Competency, and Course Objective

    ERIC Educational Resources Information Center

    Bain, Lisa Z.

    2012-01-01

    There are many different delivery methods used by institutions of higher education. These include traditional, hybrid, and online course offerings. The comparisons of these typically use final grade as the measure of student performance. This research study looks behind the final grade and compares student performance by assessment type, core…

  13. Collaborative testing for key-term definitions under representative conditions: Efficiency costs and no learning benefits.

    PubMed

    Wissman, Kathryn T; Rawson, Katherine A

    2018-01-01

    Students are expected to learn key-term definitions across many different grade levels and academic disciplines. Thus, investigating ways to promote understanding of key-term definitions is of critical importance for applied purposes. A recent survey showed that learners report engaging in collaborative practice testing when learning key-term definitions, with outcomes also shedding light on the way in which learners report engaging in collaborative testing in real-world contexts (Wissman & Rawson, 2016, Memory, 24, 223-239). However, no research has directly explored the effectiveness of engaging in collaborative testing under representative conditions. Accordingly, the current research evaluates the costs (with respect to efficiency) and the benefits (with respect to learning) of collaborative testing for key-term definitions under representative conditions. In three experiments (ns = 94, 74, 95), learners individually studied key-term definitions and then completed retrieval practice, which occurred either individually or collaboratively (in dyads). Two days later, all learners completed a final individual test. Results from Experiments 1-2 showed a cost (with respect to efficiency) and no benefit (with respect to learning) of engaging in collaborative testing for key-term definitions. Experiment 3 evaluated a theoretical explanation for why collaborative benefits do not emerge under representative conditions. Collectively, outcomes indicate that collaborative testing versus individual testing is less effective and less efficient when learning key-term definitions under representative conditions.

  14. Emergency medical services key performance measurement in Asian cities.

    PubMed

    Rahman, Nik Hisamuddin; Tanaka, Hideharu; Shin, Sang Do; Ng, Yih Yng; Piyasuwankul, Thammapad; Lin, Chih-Hao; Ong, Marcus Eng Hock

    2015-01-01

    One of the key principles in the recommended standards is that emergency medical service (EMS) providers should continuously monitor the quality and safety of their services. This requires service providers to implement performance monitoring using appropriate and relevant measures including key performance indicators. In Asia, EMS systems are at different developmental phases and maturity. This will create difficultly in benchmarking or assessing the quality of EMS performance across the region. An attempt was made to compare the EMS performance index based on the structure, process, and outcome analysis. The data was collected from the Pan-Asian Resuscitation Outcome Study (PAROS) data among few Asian cities, namely, Tokyo, Osaka, Singapore, Bangkok, Kuala Lumpur, Taipei, and Seoul. The parameters of inclusions were broadly divided into structure, process, and outcome measurements. The data was collected by the site investigators from each city and keyed into the electronic web-based data form which is secured strictly by username and passwords. Generally, there seems to be a more uniformity for EMS performance parameters among the more developed EMS systems. The major problem with the EMS agencies in the cities of developing countries like Bangkok and Kuala Lumpur is inadequate or unavailable data pertaining to EMS performance. There is non-uniformity in the EMS performance measurement across the Asian cities. This creates difficulty for EMS performance index comparison and benchmarking. Hopefully, in the future, collaborative efforts such as the PAROS networking group will further enhance the standardization in EMS performance reporting across the region.

  15. FIELD MEASUREMENT OF DISSOLVED OXYGEN: A COMPARISON OF METHODS

    EPA Science Inventory

    The ability to confidently measure the concentration of dissolved oxygen (D.O.) in ground water is a key aspect of remedial selection and assessment. Presented here is a comparison of the commonly practiced methods for determining D.O. concentrations in ground water, including c...

  16. 75 FR 17463 - Key West Bank, Key West, Florida; Notice of Appointment of Receiver

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-06

    ... DEPARTMENT OF THE TREASURY Office of Thrift Supervision Key West Bank, Key West, Florida; Notice of Appointment of Receiver Notice is hereby given that, pursuant to the authority contained in... Federal Deposit Insurance Corporation as sole Receiver for Key West Bank, Key West, Florida, (OTS No...

  17. Key Objectives Bank: Year 9. Key Stage 3: National Strategy.

    ERIC Educational Resources Information Center

    Department for Education and Skills, London (England).

    In each sub-section of the "Framework for Teaching English: Years 7, 8 and 9," certain key objectives are identified in boldface print. These objectives are key because they signify skills or understanding which are crucial to pupils' language development. They are challenging for the age group and are important markers of progress. This…

  18. Key team physical and technical performance indicators indicative of team quality in the soccer Chinese super league.

    PubMed

    Yang, Gai; Leicht, Anthony S; Lago, Carlos; Gómez, Miguel-Ángel

    2018-01-01

    The aim of this study was to identify the key physical and technical performance variables related to team quality in the Chinese Super League (CSL). Teams' performance variables were collected from 240 matches and analysed via analysis of variance between end-of-season-ranked groups and multinomial logistic regression. Significant physical performance differences between groups were identified for sprinting (top-ranked group vs. upper-middle-ranked group) and total distance covered without possession (upper and upper-middle-ranked groups and lower-ranked group). For technical performance, teams in the top-ranked group exhibited a significantly greater amount of possession in opponent's half, number of entry passes in the final 1/3 of the field and the Penalty Area, and 50-50 challenges than lower-ranked teams. Finally, time of possession increased the probability of a win compared with a draw. The current study identified key performance indicators that differentiated end-season team quality within the CSL.

  19. Finite-size analysis of continuous-variable measurement-device-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Zhang, Xueying; Zhang, Yichen; Zhao, Yijia; Wang, Xiangyu; Yu, Song; Guo, Hong

    2017-10-01

    We study the impact of the finite-size effect on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, mainly considering the finite-size effect on the parameter estimation procedure. The central-limit theorem and maximum likelihood estimation theorem are used to estimate the parameters. We also analyze the relationship between the number of exchanged signals and the optimal modulation variance in the protocol. It is proved that when Charlie's position is close to Bob, the CV-MDI QKD protocol has the farthest transmission distance in the finite-size scenario. Finally, we discuss the impact of finite-size effects related to the practical detection in the CV-MDI QKD protocol. The overall results indicate that the finite-size effect has a great influence on the secret-key rate of the CV-MDI QKD protocol and should not be ignored.

  20. Experimental quantum key distribution with finite-key security analysis for noisy channels.

    PubMed

    Bacco, Davide; Canale, Matteo; Laurenti, Nicola; Vallone, Giuseppe; Villoresi, Paolo

    2013-01-01

    In quantum key distribution implementations, each session is typically chosen long enough so that the secret key rate approaches its asymptotic limit. However, this choice may be constrained by the physical scenario, as in the perspective use with satellites, where the passage of one terminal over the other is restricted to a few minutes. Here we demonstrate experimentally the extraction of secure keys leveraging an optimal design of the prepare-and-measure scheme, according to recent finite-key theoretical tight bounds. The experiment is performed in different channel conditions, and assuming two distinct attack models: individual attacks or general quantum attacks. The request on the number of exchanged qubits is then obtained as a function of the key size and of the ambient quantum bit error rate. The results indicate that viable conditions for effective symmetric, and even one-time-pad, cryptography are achievable.

  1. Nonmarket economic user values of the Florida Keys/Key West

    Treesearch

    Vernon R. Leeworthy; J. Michael Bowker

    1997-01-01

    This report provides estimates of the nonmarket economic user values for recreating visitors to the Florida Keys/Key West that participated in natural resource-based activities. Results from estimated travel cost models are presented, including visitor’s responses to prices and estimated per person-trip user values. Annual user values are also calculated and presented...

  2. Experimentally feasible quantum-key-distribution scheme using qubit-like qudits and its comparison with existing qubit- and qudit-based protocols

    NASA Astrophysics Data System (ADS)

    Chau, H. F.; Wang, Qinan; Wong, Cardythy

    2017-02-01

    Recently, Chau [Phys. Rev. A 92, 062324 (2015), 10.1103/PhysRevA.92.062324] introduced an experimentally feasible qudit-based quantum-key-distribution (QKD) scheme. In that scheme, one bit of information is phase encoded in the prepared state in a 2n-dimensional Hilbert space in the form (|i > ±|j >) /√{2 } with n ≥2 . For each qudit prepared and measured in the same two-dimensional Hilbert subspace, one bit of raw secret key is obtained in the absence of transmission error. Here we show that by modifying the basis announcement procedure, the same experimental setup can generate n bits of raw key for each qudit prepared and measured in the same basis in the noiseless situation. The reason is that in addition to the phase information, each qudit also carries information on the Hilbert subspace used. The additional (n -1 ) bits of raw key comes from a clever utilization of this extra piece of information. We prove the unconditional security of this modified protocol and compare its performance with other existing provably secure qubit- and qudit-based protocols on market in the one-way classical communication setting. Interestingly, we find that for the case of n =2 , the secret key rate of this modified protocol using nondegenerate random quantum code to perform one-way entanglement distillation is equal to that of the six-state scheme.

  3. Measurement of the hadronic final state in deep inelastic scattering at HERA

    NASA Astrophysics Data System (ADS)

    Ahmed, T.; Andreev, V.; Andrieu, B.; Arpagaus, M.; Babaev, A.; Bärwolff, H.; Bán, J.; Baranov, P.; Barrelet, E.; Bartel, W.; Bassler, U.; Beck, G. A.; Beck, H. P.; Behrend, H.-J.; Belousov, A.; Berger, Ch.; Bergstein, H.; Bernardi, G.; Bernet, R.; Berthon, U.; Bertrand-Coremans, G.; Besançon, M.; Biddulph, P.; Binder, E.; Bizot, J. C.; Blobel, V.; Borras, K.; Bosetti, P. C.; Boudry, V.; Bourdarios, C.; Brasse, F.; Braun, U.; Braunschweig, W.; Brisson, V.; Bruncko, D.; Bürger, J.; Büsser, F. W.; Buniatian, A.; Burke, S.; Buschhorn, G.; Campbell, A. J.; Carli, T.; Charles, F.; Clarke, D.; Clegg, A. B.; Colombo, M.; Coughlan, J. A.; Courau, A.; Coutures, Ch.; Cozzika, G.; Criegee, L.; Cvach, J.; Dainton, J. B.; Danilov, M.; Dann, A. W. E.; Dau, W. D.; David, M.; Deffur, E.; Delcourt, B.; Del Buono, L.; Devel, M.; De Roeck, A.; Dingus, P.; Dollfus, C.; Dowell, J. D.; Dreis, H. B.; Drescher, A.; Duboc, J.; Düllmann, D.; Dünger, O.; Duhm, H.; Eberle, M.; Ebert, J.; Ebert, T. R.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichenberger, S.; Eichler, R.; Eisele, F.; Eisenhandler, E.; Ellis, N. N.; Ellison, R. J.; Elsen, E.; Erdmann, M.; Evrard, E.; Favart, L.; Fedotov, A.; Feeken, D.; Felst, R.; Feltesse, J.; Feng, Y.; Fensome, I. F.; Ferencei, J.; Ferrarotto, F.; Flauger, W.; Fleischer, M.; Flower, P. S.; Flügge, G.; Fomenko, A.; Fominykh, B.; Forbush, M.; Formánek, J.; Foster, J. M.; Franke, G.; Fretwurst, E.; Fuhrmann, P.; Gabathuler, E.; Gamerdinger, K.; Garvey, J.; Gayler, J.; Gellrich, A.; Gennis, M.; Gensch, U.; Genzel, H.; Gerhards, R.; Gillespie, D.; Godfrey, L.; Goerlach, U.; Goerlich, L.; Goldberg, M.; Goodall, A. M.; Gorelov, I.; Goritchev, P.; Grab, C.; Grässler, H.; Grässler, R.; Greenshaw, T.; Greif, H.; Grindhammer, G.; Gruber, C.; Haack, J.; Haidt, D.; Hajduk, L.; Hamon, O.; Handschuh, D.; Hanlon, E. M.; Hapke, M.; Haries, J.; Hartz, P.; Haydar, R.; Haynes, W. J.; Heatherington, J.; Hedberg, V.; Hedgecock, R.; Heinzelmann, G.; Henderson, R. C. W.; Henschel, H.; Herma, R.; Herynek, I.; Hildesheim, W.; Hill, P.; Hilton, C. D.; Hladký, J.; Hoeger, K. C.; Huet, Ph.; Hufnagel, H.; Huot, N.; Ibbotson, M.; Jabiol, M. A.; Jacholkowska, A.; Jacobsson, C.; Jaffre, M.; Jöhnsson, L.; Johannsen, K.; Johnson, D. P.; Johnson, L.; Jung, H.; Kalmus, P. I. P.; Kasarian, S.; Kaschowitz, R.; Kasselmann, P.; Kathage, U.; Kaufmann, H. H.; Kenyon, I. R.; Kermiche, S.; Kiesling, C.; Klein, M.; Kleinwort, C.; Knies, G.; Köhler, T.; Kolanoski, H.; Kole, F.; Kolya, S. D.; Korbel, V.; Korn, M.; Kostka, P.; Kotelnikov, S. K.; Krasny, M. W.; Krehbiel, H.; Krücker, D.; Krüger, U.; Kubenka, J. P.; Küster, H.; Kuhlen, M.; Kurça, T.; Kurzhöfer, J.; Kuznik, B.; Lander, R.; London, M. P. J.; Langkau, R.; Lanius, P.; Laporte, J. F.; Lebedev, A.; Lebedev, A.; Leuschner, A.; Leverenz, C.; Levin, D.; Levonian, S.; Ley, Ch.; Lindner, A.; Lindström, G.; Loch, P.; Lohmander, H.; Lopez, G. C.; Lüers, D.; Magnussen, N.; Malinovski, E.; Mani, S.; Marage, P.; Marks, J.; Marshall, R.; Martens, J.; Martin, R.; Martyn, H.-U.; Martyniak, J.; Masson, S.; Mavroidis, A.; Maxfield, S. J.; McMahon, S. J.; Mehta, A.; Meier, K.; Merz, T.; Meyer, C. A.; Meyer, H.; Meyer, J.; Mikocki, S.; Milone, V.; Monnier, E.; Moreau, F.; Moreels, J.; Morris, J. V.; Morton, J. M.; Müller, K.; Murín, P.; Murray, S. A.; Nagovizin, V.; Naroska, B.; Naumann, Th.; Newton, D.; Nguyen, H. K.; Niebergall, F.; Nisius, R.; Nowak, G.; Noyes, G. W.; Nyberg, M.; Oberlack, H.; Obrock, U.; Olsson, J. E.; Orenstein, S.; Ould-Saada, F.; Pascaud, C.; Patel, G. D.; Peppel, E.; Peters, S.; Phillips, H. T.; Phillips, J. P.; Pichler, Ch.; Pilgram, W.; Pitzl, D.; Prosi, R.; Raupach, F.; Rauschnabel, K.; Reimer, P.; Ribarics, P.; Riech, V.; Riedlberger, J.; Rietz, M.; Robertson, S. M.; Robmann, P.; Roosen, R.; Rostovtsev, A.; Royon, C.; Rudowicz, M.; Ruffer, M.; Rusakov, S.; Rybicki, K.; Ryseck, E.; Sacton, J.; Sahlmann, N.; Sanchez, E.; Sankey, D. P. C.; Savitsky, M.; Schacht, P.; Schleper, P.; von Schlippe, W.; Schmidt, C.; Schmidt, D.; Schmitz, W.; Schröder, V.; Schulz, M.; Schwind, A.; Scobel, W.; Seehausen, U.; Sell, R.; Seman, M.; Semenov, A.; Shekelyan, V.; Sheviakov, I.; Shooshtari, H.; Siegmon, G.; Siewert, U.; Sirois, Y.; Skillicorn, I. O.; Smirnov, P.; Smith, J. R.; Smolik, L.; Soloviev, Y.; Spitzer, H.; Staroba, P.; Steenbock, M.; Steffen, P.; Steinberg, R.; Steiner, H.; Stella, B.; Stephens, K.; Stier, J.; Strachota, J.; Straumann, U.; Struczinski, W.; Sutton, J. P.; Taylor, R. E.; Thompson, G.; Thompson, R. J.; Tichomirov, I.; Trenkel, C.; Truöl, P.; Tchernyshov, V.; Turnau, J.; Tutas, J.; Urban, L.; Usik, A.; Valkar, S.; Valkarova, A.; Vallee, C.; Van Esch, P.; Vartapetian, A.; Vazdik, Y.; Vecko, M.; Verrecchia, P.; Vick, R.; Villet, G.; Vogel, E.; Wacker, K.; Walker, I. W.; Walther, A.; Weber, G.; Wegener, D.; Wegner, A.; Wellisch, H. P.; Willard, S.; Winde, M.; Winter, G.-G.; Wolff, Th.; Womersley, L. A.; Wright, A. E.; Wulff, N.; Yiou, T. P.; Ząçek, J.; Závada, P.; Zeitnitz, C.; Ziaeepour, H.; Zimmer, M.; Zimmermann, W.; Zomer, F.; H1 Collaboration

    1993-01-01

    We report on the first experimental study of the hadronic final state in deep inelastic electron-proton scattering with the H1 detector at HERA. Energy flow and transverse momentum characteristics are measured and presented both in the laboratory and in the hadronic center of mass frames. Comparison is made with QCD models distinguished by their different treatment of parton emission.

  4. Psychometric properties of the Transitions from Foster Care Key Leader Survey.

    PubMed

    Salazar, Amy M; Brown, Eric C; Monahan, Kathryn C; Catalano, Richard F

    2016-04-01

    This study summarizes the development and piloting of the Transitions from Foster Care Key Leader Survey (TFC-KLS), an instrument designed to measure change in systems serving young people transitioning from foster care to adulthood. The Jim Casey Youth Opportunity Initiative's logic model was used as a basis for instrument development. The instrument was piloted with 119 key leaders in six communities. Seven of eight latent scales performed well in psychometric testing. The relationships among the 24 measures of system change were explored. A CFA testing overall model fit was satisfactory following slight modifications. Finally, a test of inter-rater reliability between two raters did not find reliable reporting of service availability in a supplemental portion of the survey. The findings were generally positive and supported the validity and utility of the instrument for measuring system change, following some adaptations. Implications for the field are discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Secure key storage and distribution

    DOEpatents

    Agrawal, Punit

    2015-06-02

    This disclosure describes a distributed, fault-tolerant security system that enables the secure storage and distribution of private keys. In one implementation, the security system includes a plurality of computing resources that independently store private keys provided by publishers and encrypted using a single security system public key. To protect against malicious activity, the security system private key necessary to decrypt the publication private keys is not stored at any of the computing resources. Rather portions, or shares of the security system private key are stored at each of the computing resources within the security system and multiple security systems must communicate and share partial decryptions in order to decrypt the stored private key.

  6. An image hiding method based on cascaded iterative Fourier transform and public-key encryption algorithm

    NASA Astrophysics Data System (ADS)

    Zhang, B.; Sang, Jun; Alam, Mohammad S.

    2013-03-01

    An image hiding method based on cascaded iterative Fourier transform and public-key encryption algorithm was proposed. Firstly, the original secret image was encrypted into two phase-only masks M1 and M2 via cascaded iterative Fourier transform (CIFT) algorithm. Then, the public-key encryption algorithm RSA was adopted to encrypt M2 into M2' . Finally, a host image was enlarged by extending one pixel into 2×2 pixels and each element in M1 and M2' was multiplied with a superimposition coefficient and added to or subtracted from two different elements in the 2×2 pixels of the enlarged host image. To recover the secret image from the stego-image, the two masks were extracted from the stego-image without the original host image. By applying public-key encryption algorithm, the key distribution was facilitated, and also compared with the image hiding method based on optical interference, the proposed method may reach higher robustness by employing the characteristics of the CIFT algorithm. Computer simulations show that this method has good robustness against image processing.

  7. Fundamental finite key limits for one-way information reconciliation in quantum key distribution

    NASA Astrophysics Data System (ADS)

    Tomamichel, Marco; Martinez-Mateo, Jesus; Pacher, Christoph; Elkouss, David

    2017-11-01

    The security of quantum key distribution protocols is guaranteed by the laws of quantum mechanics. However, a precise analysis of the security properties requires tools from both classical cryptography and information theory. Here, we employ recent results in non-asymptotic classical information theory to show that one-way information reconciliation imposes fundamental limitations on the amount of secret key that can be extracted in the finite key regime. In particular, we find that an often used approximation for the information leakage during information reconciliation is not generally valid. We propose an improved approximation that takes into account finite key effects and numerically test it against codes for two probability distributions, that we call binary-binary and binary-Gaussian, that typically appear in quantum key distribution protocols.

  8. Enabling interspecies epigenomic comparison with CEpBrowser.

    PubMed

    Cao, Xiaoyi; Zhong, Sheng

    2013-05-01

    We developed the Comparative Epigenome Browser (CEpBrowser) to allow the public to perform multi-species epigenomic analysis. The web-based CEpBrowser integrates, manages and visualizes sequencing-based epigenomic datasets. Five key features were developed to maximize the efficiency of interspecies epigenomic comparisons. CEpBrowser is a web application implemented with PHP, MySQL, C and Apache. URL: http://www.cepbrowser.org/.

  9. How the Contents of a Bachelor's Degree Final Project of Engineering Evolve towards Innovative Scientific Knowledge: Keys to Success

    ERIC Educational Resources Information Center

    Núñez, Cristina; Guinea, Ana; Callau, Sara; Bengoa, Christophe; Basco, Josep; Gavaldà, Jordi

    2017-01-01

    The Bachelor's Degree Final Project (BDFP) of our school aims to develop a real constructive project, enhance cooperative teamwork and increase productivity of students. We present a real case study, related with engineering and scientific innovation results obtained by BDFP, which has led to an innovative scientific study presented at the 7th…

  10. Activity measurements of a suite of radionuclides (241Am, 239,240Pu, 238Pu, 238U, 234U, 235U, 232Th, 230Th, 228Th, 228Ra, 137Cs, 210Pb, 90Sr and 40K) in biota reference material (Ocean Shellfish): CCRI(II)-S3

    NASA Astrophysics Data System (ADS)

    Nour, S.; Karam, L. R.; Inn, K. G. W.

    2012-01-01

    In 2005, the CCRI decided that a comparison undertaken from 2002 to 2008 by the NIST (under the auspices of the Inter-America Metrology System [SIM]) in the development of a new biota (Ocean Shellfish) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S3. This would enable the comparison to be used to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference materials (specifically, animal-based organic materials). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (shellfish) so as to support CMCs of similar materials submitted by the present participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Contributions from associative and explicit sequence knowledge to the execution of discrete keying sequences.

    PubMed

    Verwey, Willem B

    2015-05-01

    Research has provided many indications that highly practiced 6-key sequences are carried out in a chunking mode in which key-specific stimuli past the first are largely ignored. When in such sequences a deviating stimulus occasionally occurs at an unpredictable location, participants fall back to responding to individual stimuli (Verwey & Abrahamse, 2012). The observation that in such a situation execution still benefits from prior practice has been attributed to the possibility to operate in an associative mode. To better understand the contribution to the execution of keying sequences of motor chunks, associative sequence knowledge and also of explicit sequence knowledge, the present study tested three alternative accounts for the earlier finding of an execution rate increase at the end of 6-key sequences performed in the associative mode. The results provide evidence that the earlier observed execution rate increase can be attributed to the use of explicit sequence knowledge. In the present experiment this benefit was limited to sequences that are executed at the moderately fast rates of the associative mode, and occurred at both the earlier and final elements of the sequences. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. El Toro Library Solar Heating and Cooling Demonstration Project. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report is divided into a number of essentially independent sections, each of which covers a specific topic. The sections, and the topics covered, are as follows. Section 1 provides a brief summary description of the solar energy heating and cooling system including the key final design parameters. Section 2 contains a copy of the final Acceptance Test Report. Section 3 consists of a reduced set of final updated as-built mechanical, electrical, control and instrumentations drawings of the solar energy heating and cooling system. Section 4 provides a summary of system maintenance requirements, in the form of a maintenance schedulemore » which lists necessary maintenance tasks to be performed at monthly, quarterly, semi-annual, and annual intervals. Section 5 contains a series of photographs of the final solar energy system installation, including the collector field and the mechanical equipment room. Section 6 provides a concise summary of system operation and performance for the period of December 1981 through June 1982, as measured, computed and reported by Vitro Laboratories Division of Automation Industries, Inc., for the DOE National Solar Data Network. Section 7 provides a summary of key as-built design parameters, compared with the corresponding original design concept parameters. Section 8 provides a description of a series of significant problems encountered during construction, start-up and check-out of the solar energy heating and cooling system, together with the method employed to solve the problem at the time and/or recommendations for avoiding the problem in the future design of similar systems. Appendices A through H contain the installation, operation and maintenance submittals of the various manufacturers on the major items of equipment in the system. Reference CAPE-2823.« less

  13. A Constraint-Based Approach to Acquisition of Word-Final Consonant Clusters in Turkish Children

    ERIC Educational Resources Information Center

    Gokgoz-Kurt, Burcu

    2017-01-01

    The current study provides a constraint-based analysis of L1 word-final consonant cluster acquisition in Turkish child language, based on the data originally presented by Topbas and Kopkalli-Yavuz (2008). The present analysis was done using [?]+obstruent consonant cluster acquisition. A comparison of Gradual Learning Algorithm (GLA) under…

  14. The matrix: A comparison of international wilderness laws

    Treesearch

    Peter Landres; Brad Barr; Cyril F. Kormos

    2008-01-01

    The following matrix provides a comparison of wilderness laws around the world. This matrix is divided into four parts, each focusing on a key area of wilderness legislation: the definition of wilderness; the overall legislative purpose; uses allowed by the legislation; and administration and management requirements under law. A more thorough analysis of individual...

  15. Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system

    DOE PAGES

    Chumbley, Scott; Zhang, Song; Morris, Max; ...

    2016-11-16

    Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less

  16. Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chumbley, Scott; Zhang, Song; Morris, Max

    Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less

  17. Intake of key chronic disease-related nutrients among baby boomers.

    PubMed

    King, Dana E; Xiang, Jun; Brown, Alexander

    2014-06-01

    The dietary habits of baby boomers (people born between 1946 and 1964) undoubtedly will have a substantial impact on their future health; however, dietary information regarding the intake of key chronic disease-related nutrients is lacking for this generation. The objective of this study was to compare the dietary intake of key chronic disease-related nutrients of the baby boomer generation with the previous generation of middle-aged adults. National cross-sectional study comparison analyzing data from the National Health and Nutrition Examination Survey (NHANES) including NHANES III (1988-1994) and the NHANES for 2007-2010, focused on adult respondents ages 46 to 64 years who were not institutionalized at the time of each survey. The two cohorts were compared with regard to dietary intake of key nutritional components. The main outcome measures were intake of total calories, sodium, cholesterol, fat, fruits, vegetables, vitamin C, water, and fiber. The baby boomers' average daily intake of nutrients exceeded that of the previous generation of middle-aged adults for total calories (2118/1999), total fat (82/76 g), sodium (3513/3291 mg), and cholesterol (294/262 g; all P < 0.001). The intake of vitamin C (105/89 g), water (1208/1001 g), and vegetables (199/229 g) was less than that of the previous generation (P < 0.001), and the dietary intake of fruit and fiber was unchanged. In regression analyses, dietary changes remained significant after controlling for age, race, sex, and socioeconomic status (all P < 0.01). The study findings document higher dietary intake of key chronic disease-related nutrients along with reduced vegetable intake among baby boomers compared with the previous generation of middle-aged adults. These findings are indicative of a diet that may contribute to increased rates of chronic disease among individuals in this age group.

  18. Intake of Key Chronic Disease–Related Nutrients among Baby Boomers

    PubMed Central

    King, Dana E.; Xiang, Jun; Brown, Alexander

    2014-01-01

    Objectives The dietary habits of baby boomers (people born between 1946 and 1964) undoubtedly will have a substantial impact on their future health; however, dietary information regarding the intake of key chronic disease–related nutrients is lacking for this generation. The objective of this study was to compare the dietary intake of key chronic disease–related nutrients of the baby boomer generation with the previous generation of middle-aged adults. Methods National cross-sectional study comparison analyzing data from the National Health and Nutrition Examination Survey (NHANES) including NHANES III (1988–1994) and the NHANES for 2007–2010, focused on adult respondents ages 46 to 64 years who were not institutionalized at the time of each survey. The two cohorts were compared with regard to dietary intake of key nutritional components. The main outcome measures were intake of total calories, sodium, cholesterol, fat, fruits, vegetables, vitamin C, water, and fiber. Results The baby boomers’ average daily intake of nutrients exceeded that of the previous generation of middle-aged adults for total calories (2118/1999), total fat (82/76 g), sodium (3513/3291 mg), and cholesterol (294/262 g; all P < 0.001). The intake of vitamin C (105/89 g), water (1208/1001 g), and vegetables (199/229 g) was less than that of the previous generation (P < 0.001), and the dietary intake of fruit and fiber was unchanged. In regression analyses, dietary changes remained significant after controlling for age, race, sex, and socioeconomic status (all P < 0.01). Conclusions The study findings document higher dietary intake of key chronic disease–related nutrients along with reduced vegetable intake among baby boomers compared with the previous generation of middle-aged adults. These findings are indicative of a diet that may contribute to increased rates of chronic disease among individuals in this age group. PMID:24945165

  19. An immunohistochemical identification key for cell types in adult mouse prostatic and urethral tissue sections

    PubMed Central

    Turco, Anne E.; Gottschalk, Adam; Halberg, Richard B.; Guo, Jinjin; McMahon, Jill A.; McMahon, Andrew P.

    2017-01-01

    Though many methods can be used to identify cell types contained in complex tissues, most require cell disaggregation and destroy information about where cells reside in relation to their microenvironment. Here, we describe a polytomous key for cell type identification in intact sections of adult mouse prostate and prostatic urethra. The key is organized as a decision tree and initiates with one round of immunostaining for nerve, epithelial, fibromuscular/hematolymphoid, or vascular associated cells. Cell identities are recursively eliminated by subsequent staining events until the remaining pool of potential cell types can be distinguished by direct comparison to other cells. We validated our identification key using wild type adult mouse prostate and urethra tissue sections and it currently resolves sixteen distinct cell populations which include three nerve fiber types as well as four epithelial, five fibromuscular/hematolymphoid, one nerve-associated, and three vascular-associated cell types. We demonstrate two uses of this novel identification methodology. We first used the identification key to characterize prostate stromal cell type changes in response to constitutive phosphatidylinositide-3-kinase activation in prostate epithelium. We then used the key to map cell lineages in a new reporter mouse strain driven by Wnt10aem1(cre/ERT2)Amc. The identification key facilitates rigorous and reproducible cell identification in prostate tissue sections and can be expanded to resolve additional cell types as new antibodies and other resources become available. PMID:29145476

  20. A Round-Efficient Authenticated Key Agreement Scheme Based on Extended Chaotic Maps for Group Cloud Meeting

    PubMed Central

    Lee, Tian-Fu; Wang, Zeng-Bo

    2017-01-01

    The security is a critical issue for business purposes. For example, the cloud meeting must consider strong security to maintain the communication privacy. Considering the scenario with cloud meeting, we apply extended chaotic map to present passwordless group authentication key agreement, termed as Passwordless Group Authentication Key Agreement (PL-GAKA). PL-GAKA improves the computation efficiency for the simple group password-based authenticated key agreement (SGPAKE) proposed by Lee et al. in terms of computing the session key. Since the extended chaotic map has equivalent security level to the Diffie–Hellman key exchange scheme applied by SGPAKE, the security of PL-GAKA is not sacrificed when improving the computation efficiency. Moreover, PL-GAKA is a passwordless scheme, so the password maintenance is not necessary. Short-term authentication is considered, hence the communication security is stronger than other protocols by dynamically generating session key in each cloud meeting. In our analysis, we first prove that each meeting member can get the correct information during the meeting. We analyze common security issues for the proposed PL-GAKA in terms of session key security, mutual authentication, perfect forward security, and data integrity. Moreover, we also demonstrate that communicating in PL-GAKA is secure when suffering replay attacks, impersonation attacks, privileged insider attacks, and stolen-verifier attacks. Eventually, an overall comparison is given to show the performance between PL-GAKA, SGPAKE and related solutions. PMID:29207509

  1. Social Work Practice with Latinos: Key Issues for Social Workers

    PubMed Central

    Furman, Rich; Negi, Nalini Junko; Iwamoto, Derek Kenji; Rowan, Diana; Shukraft, Allison; Gragg, Jennifer

    2010-01-01

    The Latino population is the fastest growing group in the United States; thus, it is imperative that social workers and other mental health practitioners be knowledgeable about the current literature on how to effectively serve this population. This article elucidates key issues and knowledge, such as immigration and migration concerns; discusses how to assess for levels of acculturation; examines cultural values; and highlights salient work issues and health disparities that Latinos experience. Recommendations on how agencies and universities can recruit and promote bilingual practitioners are introduced. Finally, culturally responsive strategies for professional use of self and fostering the therapeutic alliance are discussed. PMID:19366165

  2. Key technique study and application of infrared thermography in hypersonic wind tunnel

    NASA Astrophysics Data System (ADS)

    LI, Ming; Yang, Yan-guang; Li, Zhi-hui; Zhu, Zhi-wei; Zhou, Jia-sui

    2014-11-01

    The solutions to some key techniques using infrared thermographic technique in hypersonic wind tunnel, such as temperature measurement under great measurement angle, the corresponding relation between model spatial coordinates and the ones in infrared map, the measurement uncertainty analysis of the test data etc., are studied. The typical results in the hypersonic wind tunnel test are presented, including the comparison of the transfer rates on a thin skin flat plate model with a wedge measured with infrared thermography and thermocouple, the experimental study heating effect on the flat plate model impinged by plume flow and the aerodynamic heating on the lift model.

  3. 10 CFR 950.37 - Final agreement or final decision.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Final agreement or final decision. 950.37 Section 950.37 Energy DEPARTMENT OF ENERGY STANDBY SUPPORT FOR CERTAIN NUCLEAR PLANT DELAYS Dispute Resolution Process § 950.37 Final agreement or final decision. (a) If the parties reach a Final Agreement on a contract...

  4. Linking Comparisons of Absolute Gravimeters: A Proof of Concept for a new Global Absolute Gravity Reference System.

    NASA Astrophysics Data System (ADS)

    Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.

    2016-12-01

    Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.

  5. An Extended Chaotic Maps-Based Three-Party Password-Authenticated Key Agreement with User Anonymity

    PubMed Central

    Lu, Yanrong; Li, Lixiang; Zhang, Hao; Yang, Yixian

    2016-01-01

    User anonymity is one of the key security features of an authenticated key agreement especially for communicating messages via an insecure network. Owing to the better properties and higher performance of chaotic theory, the chaotic maps have been introduced into the security schemes, and hence numerous key agreement schemes have been put forward under chaotic-maps. Recently, Xie et al. released an enhanced scheme under Farash et al.’s scheme and claimed their improvements could withstand the security loopholes pointed out in the scheme of Farash et al., i.e., resistance to the off-line password guessing and user impersonation attacks. Nevertheless, through our careful analysis, the improvements were released by Xie et al. still could not solve the problems troubled in Farash et al‥ Besides, Xie et al.’s improvements failed to achieve the user anonymity and the session key security. With the purpose of eliminating the security risks of the scheme of Xie et al., we design an anonymous password-based three-party authenticated key agreement under chaotic maps. Both the formal analysis and the formal security verification using AVISPA are presented. Also, BAN logic is used to show the correctness of the enhancements. Furthermore, we also demonstrate that the design thwarts most of the common attacks. We also make a comparison between the recent chaotic-maps based schemes and our enhancements in terms of performance. PMID:27101305

  6. Computed tomography-guided aspiration versus key-hole craniotomy for spontaneous putaminal haemorrhage: a prospective comparison of minimally invasive procedures.

    PubMed

    Zhao, J Z; Zhou, L F; Zhou, D B; Wang, R Z; Wang, M; Wang, D J; Wang, S; Yuan, G; Kang, S; Ji, N; Zhao, Y L; Ye, X

    2009-08-01

    To compare the effectiveness of two minimally invasive procedures, namely computed tomography-guided aspiration and the key-hole approach, in the neurosurgical management for spontaneous putaminal haemorrhage, and to explore the indications for the two approaches. A multicentre, single-blinded controlled trial. Hospitals taking part in this trial and the sources for patients were from China. Among others, the hospitals involved in the interventions included: the Beijing Tiantan Hospital (of the Capital University of Medical Sciences), the General Hospital of People's Liberation Army, the Peking Union Hospital, and the Shanghai Huashan Hospital (of the Fudan University medical school). From September 2001 to November 2003, data were available for analysis from a total of 841 patients with spontaneous putaminal haemorrhage from 135 hospitals all over China (except Tibet, Hong Kong, Taiwan, and Macao). All follow-up data were for at least 3 months. Mortality, Glasgow Coma Scale score, postoperative complications, Kanofsky Performance Scale score, and Barthel Index. There were 563 patients who underwent computed tomography-guided aspiration, and 165 were treated by the key-hole approach. Respective mortality rates 1 month after the operation were 17.9% and 18.3%; at 3 months they were 19.4% and 19.4%. In those undergoing computed tomography-guided aspiration, mortality rates at 3 months after the operation were 28.2% in patients with Glasgow Coma Scale scores of 8 or below, as opposed to 8.2% in those with higher scores. This amounted to a 3.4-fold difference. In those treated by the key-hole approach, the corresponding rates were 30.2% and 7.6%, which amounted to a 4-fold difference. The corresponding mortality at 3 months in patients with complications was 3.9 times as great as in those without complications. In those with haematoma volumes of 70 mL or greater, it was 2.7 times as much as in those in whom the volumes below 30 mL. The postoperative complication rate

  7. High pressure rinsing system comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Sertore; M. Fusetti; P. Michelato

    2007-06-01

    High pressure rinsing (HPR) is a key process for the surface preparation of high field superconducting cavities. A portable apparatus for the water jet characterization, based on the transferred momentum between the water jet and a load cell, has been used in different laboratories. This apparatus allows to collected quantitative parameters that characterize the HPR water jet. In this paper, we present a quantitative comparison of the different water jet produced by various nozzles routinely used in different laboratories for the HPR process

  8. Quantum dense key distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Degiovanni, I.P.; Ruo Berchera, I.; Castelletto, S.

    2004-03-01

    This paper proposes a protocol for quantum dense key distribution. This protocol embeds the benefits of a quantum dense coding and a quantum key distribution and is able to generate shared secret keys four times more efficiently than the Bennet-Brassard 1984 protocol. We hereinafter prove the security of this scheme against individual eavesdropping attacks, and we present preliminary experimental results, showing its feasibility.

  9. Immediacy bias in social-emotional comparisons.

    PubMed

    White, Katherine; Van Boven, Leaf

    2012-08-01

    In seven studies of naturally occurring, "real-world" emotional events, people demonstrated an immediacy bias in social-emotional comparisons, perceiving their own current or recent emotional reactions as more intense compared with others' emotional reactions to the same events. The events examined include crossing a scary bridge (study 1a), a national tragedy (study 1b), terrorist attacks (studies 2a and 3b), a natural disaster (study 2b), and a presidential election (study 3b). These perceived differences between one's own and others' emotions declined over time, as relatively immediate and recent emotions subsided, a pattern that people were not intuitively aware of (study 2c). This immediacy bias in social-emotional comparisons emerged for both explicit comparisons (studies 1a, 1b, and 3b), and for absolute judgments of emotional intensity (studies 2a, 2b, and 3a). Finally, the immediacy bias in social-emotional comparisons was reduced when people were reminded that emotional display norms might lead others' appearances to understate emotional intensity (studies 3a and 3b). Implications of these findings for social-emotional phenomena are discussed.

  10. Compassionate Parenting as a Key to Satisfaction, Efficacy and Meaning Among Mothers of Children with Autism.

    PubMed

    Conti, Regina

    2015-07-01

    Two studies examine the role of compassionate and self-image parenting goals in the experience of mothers of children with autism. In Study 1, a comparison sample was included. Study 1 included measures of parenting goals, life satisfaction, family life satisfaction, parenting satisfaction, and meaning in life. Study 2 incorporated a measure of parenting efficacy. Study 1 showed that mothers of children with autism were higher than comparison mothers in compassionate parenting goals. In both studies, compassionate parenting predicted positive outcomes including higher parenting satisfaction (both studies), family life satisfaction, meaning in life (Study 1) and higher parenting efficacy (Study 2). These studies support the notion that compassionate parenting is a key to satisfaction for mothers of children with autism.

  11. 33 CFR 110.189a - Key West Harbor, Key West, Fla., naval explosives anchorage area.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Key West Harbor, Key West, Fla..., DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.189a Key West Harbor, Key West, Fla., naval explosives anchorage area. (a) The anchorage ground. A circular area with its...

  12. 33 CFR 110.189a - Key West Harbor, Key West, Fla., naval explosives anchorage area.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Key West Harbor, Key West, Fla..., DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.189a Key West Harbor, Key West, Fla., naval explosives anchorage area. (a) The anchorage ground. A circular area with its...

  13. 33 CFR 110.189a - Key West Harbor, Key West, Fla., naval explosives anchorage area.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Key West Harbor, Key West, Fla..., DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.189a Key West Harbor, Key West, Fla., naval explosives anchorage area. (a) The anchorage ground. A circular area with its...

  14. 33 CFR 110.189a - Key West Harbor, Key West, Fla., naval explosives anchorage area.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Key West Harbor, Key West, Fla..., DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.189a Key West Harbor, Key West, Fla., naval explosives anchorage area. (a) The anchorage ground. A circular area with its...

  15. 33 CFR 110.189a - Key West Harbor, Key West, Fla., naval explosives anchorage area.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Key West Harbor, Key West, Fla..., DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.189a Key West Harbor, Key West, Fla., naval explosives anchorage area. (a) The anchorage ground. A circular area with its...

  16. Easing the transition: the final year of medical education at Maastricht University.

    PubMed

    van den Akker, Marjan; Dornan, Tim; Scherpbier, Albert J J A; oude Egbrink, Mirjam G A; Snoeckx, Luc H E H

    2012-01-01

    This manuscript describes the final year of medical education at Maastricht University as it has been operating since 2006. At the time external drivers for the development of a new structure of the final year were: the desire to prepare medical students for lifelong learning, the CanMEDs that were increasingly acknowledged to state the final attainment level of medical education and an increasing recognition of the importance of learning by participating actively and by taking more responsibility. Internal drivers were students' evaluations and our wish to improve instructional design and quality control. The main aim of this new final year is to better prepare students for the transition from the medical master programme to one of the postgraduate training programmes to become a medical specialist. The final year of the medical master programme consists of two 18-weeks participation electives, one in health care and one in research. Students have a higher level of autonomy and responsibility during this final year compared to the preceding medical clerkships to enhance the transition. Portfolios are the key element in examination of SCIP and HELP. Student evaluations of the final year show high scores on coaching and instructiveness. Despite some differences between departments overall scores are very high. Suggestions to improve include the availability of work places and time for education and coaching. Copyright © 2012. Published by Elsevier GmbH.

  17. A Final Approach Trajectory Model for Current Operations

    NASA Technical Reports Server (NTRS)

    Gong, Chester; Sadovsky, Alexander

    2010-01-01

    Predicting accurate trajectories with limited intent information is a challenge faced by air traffic management decision support tools in operation today. One such tool is the FAA's Terminal Proximity Alert system which is intended to assist controllers in maintaining safe separation of arrival aircraft during final approach. In an effort to improve the performance of such tools, two final approach trajectory models are proposed; one based on polynomial interpolation, the other on the Fourier transform. These models were tested against actual traffic data and used to study effects of the key final approach trajectory modeling parameters of wind, aircraft type, and weight class, on trajectory prediction accuracy. Using only the limited intent data available to today's ATM system, both the polynomial interpolation and Fourier transform models showed improved trajectory prediction accuracy over a baseline dead reckoning model. Analysis of actual arrival traffic showed that this improved trajectory prediction accuracy leads to improved inter-arrival separation prediction accuracy for longer look ahead times. The difference in mean inter-arrival separation prediction error between the Fourier transform and dead reckoning models was 0.2 nmi for a look ahead time of 120 sec, a 33 percent improvement, with a corresponding 32 percent improvement in standard deviation.

  18. Working draft of the FDA GMP final rule (Part I).

    PubMed

    Donawa, M E

    1995-10-01

    On 24 July 1995, the US Food and Drug Administration (FDA) published a notice of availability of a working draft of a final rule for new good manufacturing practice (GMP) regulations for medical devices. The new regulations could be in force by late 1996. This is the first of a two-part series of articles discussing key provisions of the working draft and their importance to companies marketing or planning to market devices in the US.

  19. Limitations on quantum key repeaters.

    PubMed

    Bäuml, Stefan; Christandl, Matthias; Horodecki, Karol; Winter, Andreas

    2015-04-23

    A major application of quantum communication is the distribution of entangled particles for use in quantum key distribution. Owing to noise in the communication line, quantum key distribution is, in practice, limited to a distance of a few hundred kilometres, and can only be extended to longer distances by use of a quantum repeater, a device that performs entanglement distillation and quantum teleportation. The existence of noisy entangled states that are undistillable but nevertheless useful for quantum key distribution raises the question of the feasibility of a quantum key repeater, which would work beyond the limits of entanglement distillation, hence possibly tolerating higher noise levels than existing protocols. Here we exhibit fundamental limits on such a device in the form of bounds on the rate at which it may extract secure key. As a consequence, we give examples of states suitable for quantum key distribution but unsuitable for the most general quantum key repeater protocol.

  20. Extending key sharing: how to generate a key tightly coupled to a network security policy

    NASA Astrophysics Data System (ADS)

    Kazantzidis, Matheos

    2006-04-01

    Current state of the art security policy technologies, besides the small scale limitation and largely manual nature of accompanied management methods, are lacking a) in real-timeliness of policy implementation and b) vulnerabilities and inflexibility stemming from the centralized policy decision making; even if, for example, a policy description or access control database is distributed, the actual decision is often a centralized action and forms a system single point of failure. In this paper we are presenting a new fundamental concept that allows implement a security policy by a systematic and efficient key distribution procedure. Specifically, we extend the polynomial Shamir key splitting. According to this, a global key is split into n parts, any k of which can re-construct the original key. In this paper we present a method that instead of having "any k parts" be able to re-construct the original key, the latter can only be reconstructed if keys are combined as any access control policy describes. This leads into an easily deployable key generation procedure that results a single key per entity that "knows" its role in the specific access control policy from which it was derived. The system is considered efficient as it may be used to avoid expensive PKI operations or pairwise key distributions as well as provides superior security due to its distributed nature, the fact that the key is tightly coupled to the policy, and that policy change may be implemented easier and faster.