Sample records for key comparison reference

  1. Linking results of key and supplementary comparisons of AC/DC voltage transfer references

    NASA Astrophysics Data System (ADS)

    Velychko, Oleh

    2018-04-01

    A regional key comparison (KC) COOMET.EM-K6.a and a supplementary comparison (SC) COOMET.EM-S1 of AC/DC voltage transfer references were conducted between participating laboratories from the Eurasian region. Measurements were made over the period 2004-2014. The results showed good agreement between all but one of the participating laboratories. The proposed procedure of linking results of key and SCs of regional metrology organization of AC/DC voltage transfer references is presented. Linking results is realized for COOMET.EM-K6.a and CCEM-K6.a KCs, and for COOMET.EM-K6.a KC and COOMET.EM-S1 SC.

  2. Comparison is key.

    PubMed

    Stone, Mark H; Stenner, A Jackson

    2014-01-01

    Several concepts from Georg Rasch's last papers are discussed. The key one is comparison because Rasch considered the method of comparison fundamental to science. From the role of comparison stems scientific inference made operational by a properly developed frame of reference producing specific objectivity. The exact specifications Rasch outlined for making comparisons are explicated from quotes, and the role of causality derived from making comparisons is also examined. Understanding causality has implications for what can and cannot be produced via Rasch measurement. His simple examples were instructive, but the implications are far reaching upon first establishing the key role of comparison.

  3. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. KEY COMPARISON: Final report, on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII, 2007

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez Blaya, Carmen

    2009-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone mole fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Key comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Buchner, Christian; Zelenka, Zoltan; Kajastie, Heikki; Madec, Tanguy; Wolf, Henning; Vámossy, Csilla; Lorefice, Salvatore; Garberg, Torgunn; Lenard, Elżbieta; Spohr, Isabel; Mares, Gabriela; Spurný, Robert; Lumbreras, Angel; Medina, Nieves; Y Akçadağ, Ümit; Perkin, Michael

    2015-01-01

    Hydrostatic density determination for liquids is mainly performed by laboratories to provide means for calibrating liquid density measuring instruments such as oscillation-type density meters. From 2002 to 2005 the CIPM key comparison CCM.D-K2 'comparison of liquid density standards' was carried out piloted by the PTB. The aim was to compare the results of the density determination by the participating laboratories to support entries to the CMC tables in this sub-field. To provide further laboratories the possibility to support their entries to the CMC tables at the meeting of the EUROMET Working Group on Density in 2007 this comparison was agreed on. BEV (Austria) organized the comparison supported by the PTB (Germany). For the comparison samples of pentadecane, water, tetrachloroethylene and of an oil of high viscosity were measured in the temperature range from 5 °C to 60 °C at atmospheric pressure by hydrostatic weighing. The measurements were completed in 2008. The reference values of the first reports based on the draft of the CCM.D-K2. After the official publication of the CCM.D-K2 the reference values were recalculated and the report was finalised in 2015. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final report on RMO Vickers key comparison COOMET M.H-K1

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Menelao, F.; Herrmann, K.; Aslanyan, A.; Pivovarov, V.; Galat, E.; Dovzhenko, Y.; Zhamanbalin, M.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales involving five National Metrology Institutes: PTB (Germany), BelGIM (Belarus), NSC IM (Ukraine), KazInMetr (Kazakhstan) and VNIIFTRI (Russia). The pilot laboratory was VNIIFTRI, and PTB acted as the linking institute to key comparisons CCM.H-K1.b and CCM.H-K1.c conducted for the Vickers hardness scales HV1 and HV30, respectively. The comparison was also conducted for the HV5 Vickers hardness scale, since this scale is most frequently used in practice in Russia and CIS countries that work according to GOST standards. In the key comparison, two sets of hardness reference blocks for the Vickers hardness scales HV1, HV5 and HV30 consisting each of three hardness reference blocks with hardness levels of 450 HV and 750 HV were used. The measurement results and uncertainty assessments for HV1 and HV30 hardness scales, as announced by BelGIM, NSC IM, KazInMetr and VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1.b and CCM.H-K1.c. The comparison results for the HV5 hardness scale are viewed as additional information, since up to today no CCM key comparisons on this scale have yet been carried out. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. KEY COMPARISON: Final Report on CCT-K7: Key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Stock, M.; Solve, S.; del Campo, D.; Chimenti, V.; Méndez-Lango, E.; Liedberg, H.; Steur, P. P. M.; Marcarino, P.; Dematteis, R.; Filipe, E.; Lobo, I.; Kang, K. H.; Gam, K. S.; Kim, Y.-G.; Renaot, E.; Bonnier, G.; Valin, M.; White, R.; Dransfield, T. D.; Duan, Y.; Xiaoke, Y.; Strouse, G.; Ballico, M.; Sukkar, D.; Arai, M.; Mans, A.; de Groot, M.; Kerkhof, O.; Rusby, R.; Gray, J.; Head, D.; Hill, K.; Tegeler, E.; Noatsch, U.; Duris, S.; Kho, H. Y.; Ugur, S.; Pokhodun, A.; Gerasimov, S. F.

    2006-01-01

    The triple point of water serves to define the kelvin, the unit of thermodynamic temperature, in the International System of Units (SI). Furthermore, it is the most important fixed point of the International Temperature Scale of 1990 (ITS-90). Any uncertainty in the realization of the triple point of water contributes directly to the measurement uncertainty over the wide temperature range from 13.8033 K to 1234.93 K. The Consultative Committee for Thermometry (CCT) decided at its 21st meeting in 2001 to carry out a comparison of water triple point cells and charged the BIPM with its organization. Water triple point cells from 20 national metrology institutes were carried to the BIPM and were compared with highest accuracy with two reference cells. The small day-to-day changes of the reference cells were determined by a least-squares technique. Prior to the measurements at the BIPM, the transfer cells were compared with the corresponding national references and therefore also allow comparison of the national references of the water triple point. This report presents the results of this comparison and gives detailed information about the measurements made at the BIPM and in the participating laboratories. It was found that the transfer cells show a standard deviation of 50 µK the difference between the extremes is 160 µK. The same spread is observed between the national references. The most important result of this work is that a correlation between the isotopic composition of the cell water and the triple point temperature was observed. To reduce the spread between different realizations, it is therefore proposed that the definition of the kelvin should refer to water of a specified isotopic composition. The CCT recommended to the International Committee of Weights and Measures (CIPM) to clarify the definition of the kelvin in the SI brochure by explicitly referring to water with the isotopic composition of Vienna Standard Mean Ocean Water (VSMOW). The CIPM

  8. CCM key comparison CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.; Lenard, E.; Lee, Y. J.; Lee, W. G.; Madec, T.; Meury, P. A.; Caceres, J.; Santos, C.; Vamossy, C.; Man, J.; Fen, K.; Toda, K.; Wright, J.; Bettin, H.; Toth, H.

    2016-01-01

    This report presents the comparison philosophy, methodology, analysis and the results of the designed CCM.D-K4 key comparison that covered the calibration of high resolution hydrometers for liquid and alcoholometers in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20°C. The main purpose of this comparison was not only to evaluate the degree of equivalence in the calibration of high accuracy hydrometers between NMI participants, but also to link, were it is possible, the results of previous comparisons to Key Comparison Reference Values (KCRVs) of CCM.D-K4. Eleven NMI laboratories took part in the CCM.D-K4 divided in two groups (petals). With the CCM.D-K4 purpose, two similar sets consisting of three hydrometers for liquid density determinations and an alcoholometer were circulated to the NMI participants as a travelling standard in the time interval from January 2011 to April 2012. Twelve Key Comparison Reference Values (KCRVs) for each petal have been obtained at the density values related to the tested density marks of the transfer standards by the results of participants. The KCRVs and corresponding uncertainties were calculated by the weighted mean in the case of consistent results, otherwise the median was used. The degree of equivalence (DoE) with respect to the corresponding KCRV was determined for each participant and, in this particular comparison, the Weighted Least Squares (WLS) method was used to link the individual DoE of each participant by a continuous function. Significant drift of the transfer standards was not detected. This report also gives instructions on calculating pair-wise degrees of equivalence, with the addition of any information on correlations that may be necessary to estimate more accurately as well as the procedure for linking international comparisons to the CCM.D-K4. Finally an example of linkage to the CCM.D-K4 is given by dealing with the results of the bilateral comparison between INRiM and NMIA, which was

  9. KEY COMPARISON: Final report on international key comparison CCQM-K53: Oxygen in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Bok Lee, Jin; Moon, Dong Min; Seog Kim, Jin; van der Veen, Adriaan M. H.; Besley, Laurie; Heine, Hans-Joachim; Martin, Belén; Konopelko, L. A.; Kato, Kenji; Shimosaka, Takuya; Perez Castorena, Alejandro; Macé, Tatiana; Milton, Martin J. T.; Kelley, Mike; Guenther, Franklin; Botha, Angelique

    2010-01-01

    Gravimetry is used as the primary method for the preparation of primary standard gas mixtures in most national metrology institutes, and it requires the combined abilities of purity assessment, weighing technique and analytical skills. At the CCQM GAWG meeting in October 2005, it was agreed that KRISS should coordinate a key comparison, CCQM-K53, on the gravimetric preparation of gas, at a level of 100 µmol/mol of oxygen in nitrogen. KRISS compared the gravimetric value of each cylinder with an analytical instrument. A preparation for oxygen gas standard mixture requires particular care to be accurate, because oxygen is a major component of the atmosphere. Key issues for this comparison are related to (1) the gravimetric technique which needs at least two steps for dilution, (2) oxygen impurity in nitrogen, and (3) argon impurity in nitrogen. The key comparison reference value is obtained from the linear regression line (with origin) of a selected set of participants. The KCRV subset, except one, agree with each other. The standard deviation of the x-residuals of this group (which consists of NMIJ, VSL, NIST, NPL, BAM, KRISS and CENAM) is 0.056 µmol/mol and consistent with the uncertainties given to their standard mixtures. The standard deviation of the residuals of all participating laboratory is 0.182 µmol/mol. With respect to impurity analysis, overall argon amounts of the cylinders are in the region of about 3 µmol/mol however; four cylinders showed an argon amount fraction over 10 µmol/mol. Two of these are inconsistent with the KCRV subset. The explicit separation between two peaks of oxygen and argon in the GC chromatogram is essential to maintain analytical capability. Additionally oxygen impurity analysis in nitrogen is indispensable to ensure the preparative capability. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The

  10. Final report on COOMET Vickers PTB/VNIIFTRI key comparison (COOMET.M.H-K1.b and COOMET.M.H-K1.c)

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Herrmann, K.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales of two National Metrology Institutes—PTB and VNIIFTRI. The pilot laboratory was PTB, which was the linking institute with the key comparison reference values of CCM.H-K1. In the key comparison two sets of hardness reference blocks for the Vickers hardness scales HV1 and HV30, each consisting of three hardness reference blocks with the hardness levels 240 HV, 540 HV and 840 HV, are used. The same hardness reference blocks were used previously in the key comparison CCM.H-K1. The measurement results and uncertainty assessments, announced by VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. KEY COMPARISON Final report on international comparison CCQM-K71: Measurement of stack gas

    NASA Astrophysics Data System (ADS)

    Nieuwenkamp, G.; van der Veen, A. M. H.; Wessel, R. M.; Qiao, Han; Oh, Sang-Hyub; Kim, Byung-Moon; Kim, Kwang-Sub; Pérez Castorena, Alejandro; Ramírez Nambo, Carlos; Koelliker Delgado, Jorge; Serrano Caballero, Victor M.; Rangel Murillo, Francisco; Avila Salas, Manuel de Jesus; Dias, Florbela; Baptista, Gonçalo; Konopelko, L. A.; Kustikov, Y. A.; Pankratov, V. V.; Selyukov, D. N.; Balandovich, V. S.; Vishnyakov, I. M.; Pavlov, M. V.; Maltsev, M. A.; Botha, Angelique; Valkova, Miroslava; Stovcik, Viliam; Musil, Stanislav; Milton, M. J. T.; Uprichard, I. J.; Vargha, G. M.; Guenther, F.; Gameson, L.; da Cunha, V.

    2010-01-01

    Industrial stack gas emission measurements are important for process control, control of air pollution, and for implementing legislation regarding carbon dioxide emission rights. Measurements are typically performed using a range of process analysers for carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOx), sulphur dioxide (SO2) and miscellaneous hydrocarbons. The calibration of these analysers is often performed using a series of binary mixtures of each component in nitrogen. For reasons of efficiency as well as a better match with true stack gas, the use of multi-component mixtures for this purpose would be preferred. The aim of this key comparison is to evaluate the measurement capabilities of national metrology institutes for carbon monoxide, carbon dioxide, nitrogen monoxide, sulphur dioxide and propane in nitrogen. Ten laboratories participated in the key comparison and one in the associated study. The key comparison reference value is based on the gravimetric preparation data. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII (December 2014)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2015-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Linking Comparisons of Absolute Gravimeters: A Proof of Concept for a new Global Absolute Gravity Reference System.

    NASA Astrophysics Data System (ADS)

    Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.

    2016-12-01

    Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.

  14. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII, March 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NPL, April 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Sweeney, Bryan; Quincey, Paul

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone standard of the United Kingdom maintained by the National Physical Laboratory (NPL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with VSL, September 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Heikens, Dita; van der Veen, Adrian

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Netherlands maintained by the Van Swinden (VSL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NIST, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Hodges, Joe; Norris, James E.

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the National Institute of Standards and Technology (NIST) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with INECC, September 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Fentanes, Oscar; Benítez, Ángeles; Ordoñez, Daniel

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of Mexico maintained by the National Institute of Ecology and Climate Change (INECC) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report on CCM key comparison CCM.D-K2: Comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Jacques, Claude; Zelenka, Zoltán; Fujii, Ken-ichi; Kuramoto, Naoki; Chang, Kyung-Ho; Lee, Yong Jae; Becerra, Luis Omar; Domostroeva, Natalia

    2013-01-01

    The results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10-5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database

  20. KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. KEY COMPARISON: Key comparison CCQM-K60: Total selenium and selenomethionine in selenised wheat flour

    NASA Astrophysics Data System (ADS)

    Goenaga Infante, Heidi; Sargent, Mike

    2010-01-01

    Key comparison CCQM-K60 was performed to assess the analytical capabilities of national metrology institutes (NMIs) to accurately quantitate the mass fraction of selenomethionine (SeMet) and total selenium (at low mg kg-1 levels) in selenised wheat flour. It was organized by the Inorganic Analysis Working Group (IAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) as a follow-up key comparison to the previous pilot study CCQM-P86 on selenised yeast tablets. LGC Limited (Teddington, UK) and the Institute for National Measurement Standards, National Research Council Canada (NRCC, Ottawa, Canada) acted as the coordinating laboratories. CCQM-K60 was organized in parallel with a pilot study (CCQM-P86.1) involving not only NMIs but also expert laboratories worldwide, thus enabling them to assess their capabilities, discover problems and learn how to modify analytical procedures accordingly. Nine results for total Se and four results for SeMet were reported by the participant NMIs. Methods used for sample preparation were microwave assisted acid digestion for total Se and multiple-step enzymatic hydrolysis and hydrolysis with methanesulfonic acid for SeMet. For total Se, detection techniques included inductively coupled plasma mass spectrometry (ICP-MS) with external calibration, standard additions or isotope dilution analysis (IDMS); instrumental neutron activation analysis (INAA); and graphite furnace atomic absorption spectrometry (GFAAS) with external calibration. For determination of SeMet in the wheat flour sample, the four NMIs relied upon measurements using species-specific IDMS (using 76Se-enriched SeMet) with HPLC-ICP-MS. Eight of the nine participating NMIs reported results for total Se within 3.5% deviation from the key comparison reference value (KCRV). For SeMet, the four participating NMIs reported results within 3.2% deviation from the KCRV. This shows that the performance of the majority of the CCQM-K60 participants was very good

  2. KEY COMPARISON: CCQM-K21 Key Comparison Determination of pp’-DDT in fish oil

    NASA Astrophysics Data System (ADS)

    Webb, K. S.; Carter, D.; Wolff Briche, C. S. J.

    2003-01-01

    A key comparison on the determination of (pp'-dichlorodiphenyl) trichloroethane (pp'-DDT) in a fish oil matrix has been successfully completed. Nine NMIs participated in this key comparison and used the technique of isotope dilution gas-chromatography mass spectrometry (ID/GC/MS) for the determinations. Two samples (A and B) of fish oil were distributed to participants, each gravimetrically spiked with pp'-DDT. The KCRV for Sample A is 0.0743 +/- 0.0020 µg g-1 and that of Sample B is 0.1655 +/- 0.0014 µg g-1 of pp'-DDT in fish oil. The results for Sample A showed a RSD of 3.5%, the RSD for Sample B was within 1%. These results were an improvement over those of the corresponding pilot study (CCQM-P21), where at a mass fraction of pp'-DDT in fish oil of 0.311 µg g-1 the RSD was 2.6%. The compound pp'-DDT is a typical organochlorine pesticide and this key comparison has shown that NMIs have the ability to measure such compounds at levels typically found in the environment. The compound (pp'-dichlorodiphenyl) dichloroethylene (pp'-DDE), a metabolite of pp'-DDT, was the subject of a previous key comparison (CCQM-K5). The compound pp'-DDT is technically more challenging than that of pp'-DDE since it can decompose during the measurement procedure. Consequently the success of this key comparison, combined with that of CCQM-K5 demonstrates a broad measurement capability by NMIs for organochlorine compounds in the environment. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  3. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2010)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2011-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2012)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2013-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Final report, on-going key comparison BIPM.QM-K1: ozone at ambient level, comparison with DMDM, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, J.; Moussay, P.; Wielgosz, R.; Bebic, J.; Norris, J. E.; Guenther, F.

    2016-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Directorate of Measures and Precious Metals (DMDM) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NMISA, June 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Ntsasa, Napo G.; Tshilongo, James; Mphaphuli, Gumani E.; Norris, James E.; Hodges, Joseph T.

    2018-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of South Africa maintained by the National Metrology Institute of South Africa (NMISA) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with CMS-ITRI, June 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Lin, Tsai-Yin; Norris, James E.; Hodges, Joseph T.

    2017-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the ITRI Center for Measurement Standards (CMS-ITRI) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. EURAMET.T-K7 Key Comparison of Water Triple-Point Cells

    NASA Astrophysics Data System (ADS)

    Peruzzi, A.; Bosma, R.; Kerkhof, O.; Rosenkranz, P.; Del Campo Maldonado, M. D.; Strnad, R.; Nielsen, J.; Anagnostou, M.; Veliki, T.; Zvizdic, D.; Grudnewicz, E.; Nedea, M.; Neagu, D. M.; Steur, P.; Filipe, E.; Lobo, I.; Antonsen, I.; Renaot, E.; Heinonen, M.; Weckstrom, T.; Bojkovski, J.; Turzo-Andras, E.; Nemeth, S.; White, M.; Tegeler, E.; Dobre, M.; Duris, S.; Kartal Dogan, A.; Uytun, A.; Augevicius, V.; Pauzha, A.; Pokhodun, A.; Simic, S.

    2011-12-01

    The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the "mother" comparison CCT-K7 is discussed in detail.

  10. Final report of the key comparison of APMP.AUV.V-K2

    NASA Astrophysics Data System (ADS)

    Usuda, Takashi; Ota, Akihiro; Nozato, Hideaki; Ishigami, Tamio; Kokuyama, Wataru; Plangsangmas, Virat; Rattanangkul, Pairoj; Yih Tsuei, Kuang; Huang, Yu-Chung; Chee Keong, Chan; Shan, Cui

    2017-01-01

    A key comparison of vibration acceleration APMP.AUV.V-K2, which is an upgrade from APMP.AUV.V-K1.1, has been made within the Asia Pacific Metrology Programme (APMP) to include three national laboratories; the CMS-ITRI (Chinese Taipei), the NIMT (Thailand) and the A*Star (Singapore). One pilot laboratory, the NMIJ (Japan), participated to link the RMO APMP results to the CIPM CC key comparison (CCAUV.V-K2), according to the decision of the CCAUV10/D7 during the 10th CCAUV meeting. The admissible acceleration amplitude ranges from 10 m/s2 to 200 m/s2 over the frequency range from 40 Hz to 5 kHz. The RMO APMP results demonstrate the agreement with the key comparison reference value of CCAUV.V-K2 within the expanded uncertainties considering the armature effect of vibration exciter in a high-frequency range. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report on CIPM key comparison CCM.FF-K6.2011: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John

    2014-01-01

    The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. SIM key comparison for luminous flux. SIM.PR-K4

    NASA Astrophysics Data System (ADS)

    Matamoros, Carlos H.; Ohno, Yoshi; Zwinkels, Joanne; Cogno, Jorge A.; Couceiro, Iakyra B.

    2016-01-01

    In compliance with the established BIPM and CCPR policies and guidelines on comparisons, the SIM Photometry and Radiometry Working Group decided to conduct a key comparison on total luminous flux in order to provide an opportunity for its member National Metrology Institutes (NMIs) that did not participate in the CCPR-K4 comparison, to get a link to the reference value obtained for this quantity (the lumen) and to derive the corresponding degrees of equivalence. This SIM.PR-K4 was piloted by Centro Nacional de Metrología (CENAM), the NMI of Mexico and included the participation of five laboratories: CENAM (Mexico), INTI (Argentina), INMETRO (Brazil), NIST (USA, linking lab), and NRC (Canada, linking lab). The comparison, conducted in star type scheme, was run using three to four lamps per participant, and results are given in this report, including the unilateral degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. KEY COMPARISON: Report of the spectral irradiance comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

    NASA Astrophysics Data System (ADS)

    Ojanen, M.; Shpak, M.; Kärhä, P.; Leecharoen, R.; Ikonen, E.

    2009-01-01

    A bilateral comparison of the spectral irradiance scales between MIKES (Finland) and NIMT (Thailand) was carried out at 22 wavelengths between 290 nm and 900 nm. MIKES acted as the pilot and link to the results of the key comparison CCPR-K1.a. The spectral irradiance values measured by NIMT generally agree with the key comparison reference value within the expanded uncertainty. The only exceptions are results at wavelengths 300 nm, 450 nm and 500 nm, where the ratios between the degree of equivalence (DoE) and the expanded uncertainty of DoE (k = 2) are 1.0, 1.4 and 1.2, respectively. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. KEY COMPARISON Bilateral comparison of 1.018 V and 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2010 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2010-01-01

    As a part of the ongoing BIPM key comparisons BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and of the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2010. Two BIPM Zener diode-based travelling standards were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage is maintained at the 10 V level by means of a group of characterized Zener diode-based electronic voltage standards. The output EMF of each travelling standard, at the 10 V output terminals, was measured by direct comparison with the group standard. Measurements of the output EMF of the travelling standards at the 1.018 V output terminals were made using a potentiometer, standardized against the local 10 V reference standard. At the BIPM, the travelling standards were calibrated at both voltages before and after the measurements at NSAI-NML, using the BIPM Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Final report on key comparison CCQM-K100: Analysis of copper in ethanol

    NASA Astrophysics Data System (ADS)

    Zhou, Tao; Kakoulides, Elias; Zhu, Yanbei; Jaehrling, Reinhard; Rienitz, Olaf; Saxby, David; Phukphatthanachai, Pranee; Yafa, Charun; Labarraque, Guillaume; Cankur, Oktay; Can, Süleyman Z.; Konopelko, Leonid A.; Kustikov, Yu A.; Caciano de Sena, Rodrigo; Marques Rodrigues, Janaina; Fonseca Sarmanho, Gabriel; Fortunato de Carvalho Rocha, Werickson; dos Reis, Lindomar Augusto

    2014-01-01

    The increase in renewable sources in the energy matrix of the countries is an effort to reduce dependency on crude oil and the environmental impacts associated with its use. In order to help overcome the lack of widely accepted quality standards for fuel ethanol and to guarantee its competitiveness in the international trade market, the NMIs have been working to develop certified reference materials for bio-fuels and measurement methods. Inorganic impurities such as Cu, Na and Fe may be present in the fuel ethanol and their presence is associated with corrosion and the formation of oxide deposits in some engine parts. The key comparison CCQM-K100 was carried out under the auspices of the Inorganic Analysis Working Group (IAWG) and the coordination of the National Institute of Metrology, Quality and Technology (INMETRO). The objective of this key comparison was to compare the measurement capabilities of the participants for the determination of Cu in fuel ethanol. Ten NMIs participated in this exercise and most of them used the isotopic dilution method for determining the amount of Cu. The median was chosen as key comparison reference value (KCRV). The assigned KCRV for the Cu content was 0.3589 µg/g with a combined standard uncertainty of 0.0014 µg/g. In general, there is a good agreement among the participants' results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report on key comparison CCQM-K81: Chloramphenicol in pig muscle

    NASA Astrophysics Data System (ADS)

    Polzer, Joachim; Henrion, Andre; Gowik, Petra

    2013-01-01

    Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K81 'Chloramphenicol in pig muscle', was coordinated by BVL and PTB in 2009/2010. Six NMIs/DIs participated in this comparison. Chloramphenicol (CAP) is an effective broad-spectrum antibiotic which can in principle be used for the treatment of humans and animals. Its use for the treatment of food-producing animals is, however, forbidden worldwide in many countries due to potential severe side effects. The key comparison was the follow-up to the successful pilot study 'CCQM-P90: chloramphenicol in milk'. With this key comparison it was intended to demonstrate the capability of NMIs/DIs to analyse traces of CAP in food at concentration levels resulting from legal requirements for food control. Additionally, the quality of this kind of analysis with respect to compliance with legal requirements for food control methods and the international comparability of measurements should be evaluated in general. The study was classified as a 'track C' study (studies in emerging areas of global interest). For the study incurred lyophilised pig muscle material containing CAP (at a mass-fraction level around the maximum allowable level for import for a number of countries) has been produced as a candidate reference material by BVL and IRMM (Institute for Reference Materials and Measurements, JRC of the European Commission). Animal treatment and slaughtering of the animal to gain incurred muscle material as well as pre-testing of the CAP content was done at the BVL. The IRMM did further processing of the material and testing of homogeneity and stability. Participants were invited to assign the mass fraction of free CAP in the comparison sample. CCQM-K81 demonstrated successfully the capability of the participating laboratories to assign chloramphenicol values in tissue down to residue levels of around 0.3 ng/g (referring to the

  18. Final report of the APMP water flow key comparison: APMP.M.FF-K1

    NASA Astrophysics Data System (ADS)

    Lee, Kwang-Bock; Chun, Sejong; Terao, Yoshiya; Thai, Nguyen Hong; Tsair Yang, Cheng; Tao, Meng; Gutkin, Mikhail B.

    2011-01-01

    The key comparison, APMP.M.FF-K1, was undertaken by APMP/TCFF, the Technical Committee for Fluid Flow (TCFF) under the Asia Pacific Metrology Program (APMP). One objective of the key comparison was to demonstrate the degree of equivalence among six participating laboratories (KRISS, NMIJ, VMI, CMS, NIM and VNIIM) in water flow rate metrology by comparing the results with the key comparison reference value (KCRV) determined from the CCM.FF-K1 key comparison. The other objective of this key comparison was to provide supporting evidence for the calibration and measurement capabilities (CMCs), which had been declared by the participating laboratories during this key comparison. The Transfer Standard Package (TSP) was a Coriolis mass flowmeter, which had been used in the CCM.FF-K1 key comparison. Because the K-factors in the APMP.M.FF-K1 key comparison were slightly lower than the K-factors of the CCM.FF-K1 key comparison due to long-term drifts of the TSP, a correction value D was introduced. The value of D was given by a weighted sum between two link laboratories (NMIJ and KRISS), which participated in both the CCM.FF-K1 and the APMP.M.FF-K1 key comparisons. By this correction, the K-factors were laid between 12.004 and 12.017 at either low (Re = 254 000) or high (Re = 561 000) flow rates. Most of the calibration data were within expected uncertainty bounds. However, some data showed undulations, which gave large fluctuations of the metering factor at Re = 561 000. Calculation of degrees of equivalence showed that all the participating laboratories had deviations between -0.009 and 0.007 pulses/kg from the CCM.FF-K1 KCRV at either the low or the high flow rates. In case of En calculation, all the participating laboratories showed values less than 1, indicating that the corrected K-factors of all the laboratories were equivalent with the KCRV at both Re = 254 000 and 561 000. When the corrected K-factors from two participating laboratories were compared, all the

  19. Security of Distributed-Phase-Reference Quantum Key Distribution

    NASA Astrophysics Data System (ADS)

    Moroder, Tobias; Curty, Marcos; Lim, Charles Ci Wen; Thinh, Le Phuc; Zbinden, Hugo; Gisin, Nicolas

    2012-12-01

    Distributed-phase-reference quantum key distribution stands out for its easy implementation with present day technology. For many years, a full security proof of these schemes in a realistic setting has been elusive. We solve this long-standing problem and present a generic method to prove the security of such protocols against general attacks. To illustrate our result, we provide lower bounds on the key generation rate of a variant of the coherent-one-way quantum key distribution protocol. In contrast to standard predictions, it appears to scale quadratically with the system transmittance.

  20. Longitudinal meta-analysis of NIST pH Standard Reference Materials(®): a complement to pH key comparisons.

    PubMed

    Pratt, Kenneth W

    2015-04-01

    This meta-analysis assesses the long-term (up to 70 years) within-laboratory variation of the NIST pH Standard Reference Material® (SRM) tetroxalate, phthalate, phosphate, borate, and carbonate buffers. Values of ΔpH(S), the difference between the certified pH value, pH(S), of each SRM issue and the mean of all pH(S) values for the given SRM at that Celsius temperature, t, are graphed as a function of the SRM issue and t. In most cases, |ΔpH(S)| < 0.004. Deviations from the nominal base:acid amount (mole) ratio of a buffer yield t-independent, constant shifts in ΔpH(S). The mean ΔpH(S) characterizes such deviations. The corresponding mole fraction of impurity in the conjugate buffer component is generally <0.3 %. Changes in the equipment, personnel, materials, and methodology of the pH(S) measurement yield t-dependent variations. The standard deviation of ΔpH(S) characterizes such changes. Standard deviations of ΔpH(S) are generally 0.0015 or less. The results provide a long-term, single-institution complement to the time-specific, multi-institution results of pH key comparisons administered by the Consultative Committee for Metrology in Chemistry and Biology (CCQM).

  1. KEY COMPARISON: CCQM-K25: Determination of PCB congeners in sediment

    NASA Astrophysics Data System (ADS)

    Schantz, Michele; Wise, Stephen

    2004-01-01

    Polychlorinated biphenyls (PCBs) consist of 209 possible congeners depending on the substitution of the chlorine atoms around the biphenyl molecule. PCBs have been widely used as industrial fluids, flame retardants, diluents, hydraulic fluids, and dielectric fluids for capacitors and transformers. As a class of compounds, they are environmentally stable and tend to bioaccumulate. Of the 209 possible congeners, approximately 150 congeners have been reported in the environment. Congener-specific PCB methods, which are typically based on gas chromatography (GC) with electron capture detection (ECD) or mass spectrometric (MS) detection, are designed to measure selected priority congeners, but the congeners of interest change with the study and sponsoring agency. A pilot study (CCQM-P17) for the determination of PCB congeners in sediment was organized by NIST and NRC-Canada in 2000. Ten laboratories participated in the pilot study. After discussion and critical review of the data, there was agreement that the pilot study should be followed by a Key Comparison and that the Key Comparison Reference Value (KCRV) should be derived from isotope dilution GC/MS (ID-GC/MS) based methods that had been validated in the Pilot Study. The CCQM-K25 Key Comparison study utilized a sediment sample prepared by mixing known quantities of two sediment materials to simulate a moderately contaminated sample with respect to PCBs. Nine laboratories participated in CCQM-K25 and demonstrated a high level of equivalence in capabilities for determining five PCB congeners (congener numbers 28, 101, 105, 153, and 170) in a moderately contaminated sediment using GC/MS-based methods. The amount of substance concentration for the congeners measured ranged from ~10 ng/g to ~35 ng/g. The relative expanded uncertainties of the KCRVs ranged from 2% to 5%, indicating excellent agreement among the participants that used ID-GC/MS. Results from the one laboratory that used GC/MS with a non-labeled PCB

  2. Final report on the key comparison CCPR-K5: Spectral diffuse reflectance

    NASA Astrophysics Data System (ADS)

    Nadal, Maria; Eckerle, Kenneth L.; Early, Edward A.; Ohno, Yoshi

    2013-01-01

    The CCPR K5 key comparison on spectral diffuse reflectance was carried out in the framework of the CIPM Mutual Recognition Arrangement, by 13 national metrology institutes (MMIs) as participants. The participants were CSIR-NML (South Africa), HUT (Finland), IFA-CSIC (Spain), KRISS (Republic of Korea), MSL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NPL (United Kingdom), NRC (Canada), OMH (Hungary), PTB (Germany) and VNIIOFI (Russia Federation). NIST (USA) piloted the comparison. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 820 nm at 20 nm increment. The comparison was a star type comparison with the samples provided by the pilot laboratory and with the measurement sequence: Pilot-Participant-Pilot. Spectralon and matte white ceramic tiles were used as the transfer standards. Each participant received three of each type of sample and at least one sample of each type was measured three times on three separate days, and the other two samples were measured once. The report presents the description of the measurement facilities, procedures and uncertainties of all the participants as well as the results of the comparison. Measurement results from the participants and their associated uncertainties were analyzed in accordance with the Guidelines for CCPR Key Comparison Report Preparation, using weighted mean with cut-off. For the calculation of the Key Comparison Reference Value (KCRV), as agreed by the participants, the data of both samples were used for the 460 nm to 820 nm region and only the data of the Spectralon samples were used in the spectral region of 360 nm to 440 nm. The unilateral degrees of equivalence (DoE) calculated for each participant are mostly consistent within the uncertainty (k = 2) of the DoE. This international comparison of spectral diffuse reflectance

  3. CCQM-K103 key comparison melanine in milk powder

    NASA Astrophysics Data System (ADS)

    Li, Xiuqin; Zhang, Qinghe; Li, Hongmei; Li, Mengwan; Wong, Siu-kay; Lee, Foo-Wing; Kakoulides, Elias; Naujaus, Evaldas; Fernandes-Whaley, Maria; Prevoo-Franzsen, Des; Quinn, Laura; Pookrod, Preeyaporn; Konopelko, Leonid

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K103, was coordinated by the National Institute of Metrology (NIM) and Government Laboratory, Hong Kong, China (GLHK). The comparison was designed to demonstrate NMIs/DIs ability to analyze traces of melamine in milk and milk powder at concentration levels resulting from requirements for food safety. Seven NMIs or DIs participated in the comparison. Final reference value (KCRV) is 0.286 mg/kg, with standard uncertainty of the median as 0.011 mg/kg (3.8 %). The k-factor for the estimation of the expanded uncertainty was chosen as k = 2.57 ( t (0.05;5) ), thus the expanded uncertainty is 0.028 mg/kg (9.8%). The degrees of equivalence with melamine in milk powder KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for IDMS in determining mass fractions in the range from 0.1 to 5.0 mg/kg of analytes with low molar mass (range 50-300 Da) with high polarity (pKow > -2.0) in milk and milk products. Extension to other analytes and matrices should be applied with care since there is a close linkage to other relevant parameters as e.g. sample preparation procedures (liquid/liquid extraction, SPE clean-up) and analytical separation techniques (e.g., GC-MS, LC-MS/MS etc). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. KEY COMPARISON: Final report of International Comparison EUROMET.QM-K1c: Comparison of measurements of nitrogen monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, A. M. H.; Nieuwenkamp, G.; Oudwater, R.; Wessel, R. M.; Novak, J.; Perrochet, J.-F.; Ackermann, A.; Rakowska, A.; Cortez, L.; Dias, F.; Konopelko, L.; Kustikov, Y.; Sutour, C.; Masé, T.; Milton, M. J. T.; Uprichard, I. J.; Woods, P. T.; Walden, J.; Lopez Esteban, M. T.

    2005-01-01

    Following-up the key comparison CCQM-K1c, EUROMET organized a regional key comparison involving ten laboratories. The objectives of this EUROMET key comparison were essentially the same as for the CCQM-K1c comparison: to compare the measurement capabilities of national metrological institutes (NMIs) in measuring amount of substance fractions of nitrogen monoxide in nitrogen. The nominal amount of substance fraction of the standards used for the comparison was 100 µmol/mol. The pilot laboratory in this key comparison also piloted the CCQM key comparison and has long-term experience in the behaviour of these mixtures and the technical challenges in preparing batches of very similar mixtures. Most participants used chemiluminescence as the measurement method; two participants used UV techniques and one ND-IR. The degrees of equivalence between this comparison and CCQM-K1c were calculated; four laboratories participated in both key comparisons, thus providing sufficient data for demonstrating the comparability. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  5. KEY COMPARISON: BIPM comparison BIPM.RI(II)-K1.Cu-64 of the activity measurements of the radionuclide 64Cu

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Kossert, K.; Nähle, O. J.

    2009-01-01

    In 2009, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted a sample of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The value of the activity submitted was about 9.3 MBq. The result of this new comparison has been approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), comparison identifier BIPM.RI(II)-K1.Cu-64. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Phase-Reference-Free Experiment of Measurement-Device-Independent Quantum Key Distribution

    NASA Astrophysics Data System (ADS)

    Wang, Chao; Song, Xiao-Tian; Yin, Zhen-Qiang; Wang, Shuang; Chen, Wei; Zhang, Chun-Mei; Guo, Guang-Can; Han, Zheng-Fu

    2015-10-01

    Measurement-device-independent quantum key distribution (MDI QKD) is a substantial step toward practical information-theoretic security for key sharing between remote legitimate users (Alice and Bob). As with other standard device-dependent quantum key distribution protocols, such as BB84, MDI QKD assumes that the reference frames have been shared between Alice and Bob. In practice, a nontrivial alignment procedure is often necessary, which requires system resources and may significantly reduce the secure key generation rate. Here, we propose a phase-coding reference-frame-independent MDI QKD scheme that requires no phase alignment between the interferometers of two distant legitimate parties. As a demonstration, a proof-of-principle experiment using Faraday-Michelson interferometers is presented. The experimental system worked at 1 MHz, and an average secure key rate of 8.309 bps was obtained at a fiber length of 20 km between Alice and Bob. The system can maintain a positive key generation rate without phase compensation under normal conditions. The results exhibit the feasibility of our system for use in mature MDI QKD devices and its value for network scenarios.

  7. KEY COMPARISON: Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

    NASA Astrophysics Data System (ADS)

    Hung, Chen-Chuan; Jian, Wu; Changpan, Tawat

    2009-01-01

    This report describes the key comparison APMP.M.P-K6.1 among the three national metrology institutes, Center for Measurement Standards-ITRI (CMS-ITRI, Taiwan), SPRING Singapore and National Institute of Metrology (NIMT), in the pressure range from 20 kPa to 105 kPa in gas media and gauge mode executed during the period April 2003 to April 2004. This comparison was conducted by CMS-ITRI and was based on the calibration procedure of APMP pneumatic pressure comparison APMP.M.P-K6. We intended to link to the CCM.P-K6 key comparison through the APMP.M.P-K6 key comparison by using the proposed linkage method in the APMP.M.P-K6 key comparison to determine a linking factor that can transform the quantities measured in the APMP.M.P-K6.1 key comparison. All three participating institutes used pneumatic piston gauges as their pressure standards. The Ruska 2465 gas-operated piston-cylinder assembly TL-1409 used as transfer standard offered by CMS-ITRI was calibrated three times by the pilot institute during the comparison period and showed that it was very stable after evaluation. The comparison was conducted on the basis of cross-float experiments to determine the effective area of transfer standards from the national standards of three institutes. The comparison results (as shown in Table 6) were equivalent to the CCM.P-K6 comparison and the relative bilateral degrees of equivalence between two laboratories were smaller than 39.7 × 10-6 from 20 kPa to 105 kPa. These results showed all participating institutes measuring the same quantity in the whole pressure range lay within their expanded uncertainty with confidence level 95%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Final report on EUROMET key comparison EUROMET.M.D-K2 (EUROMET 627) "Comparison of density determinations of liquid samples"

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Heinonen, Martti; Gosset, André; Zelenka, Zoltán; Lorefice, Salvatore; Hellerud, Kristen; Durlik, Hanna; Jordaan, Werner; Field, Ireen

    2016-01-01

    The results of the key comparison EUROMET 627 (EUROMET.M.D-K2) are presented. This project covered the density measurements of three liquids: dodecane, water and an oil of high viscosity measured at 15 °C, 20 °C and 40 °C. Seven European metrology laboratories and the South African laboratory CSIR-NML (now: NMISA) measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards between 04 October 2001 and 18 December 2001. The stability and homogeneity of the liquids were investigated by the pilot laboratory PTB. The results generally show good agreement among the participants. Only for the simple Mohr-Westphal balances do the uncertainties seem to be underestimated by the laboratories. Furthermore, the measurement of high-viscosity oil was difficult for some laboratories. Nevertheless, the five laboratories PTB/DE, BNM/FR (now: LNE/FR), OMH/HU (now: MKEH/HU), IMGC/IT (now: INRIM/IT) and GUM/PL agree with each other for stated uncertainties of 0.05 kg/m3 or less. This satisfies the current needs of customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. No reference values were calculated since the subsequent CCM key comparison CCM.D-K2 had a different scope and the EUROMET 627 comparison was soon superseded by the EURAMET 1019 (EURAMET.M.D-K2) comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final Report on the Key Comparison CCM.P-K4.2012 in Absolute Pressure from 1 Pa to 10 kPa

    PubMed Central

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. PMID:28216793

  10. KEY COMPARISON Final report on APMP.EM-K6.a: APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty

    NASA Astrophysics Data System (ADS)

    Budovsky, Ilya

    2010-01-01

    The APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty, APMP.EM-K6a, started in 2000 and concluded in 2003. This comparison has offered the same range and frequencies as the key comparison CCEM-K6a with the view of providing the National Metrology Institutes (NMIs) of the APMP member economies with an opportunity to link the values of their standards for ac-dc transfer difference to the international reference values. The ac-dc difference of the travelling standard was measured with 3 V applied at standard frequencies of 1 kHz, 20 kHz, 100 kHz and 1 MHz, and optional frequencies of 50 kHz and 500 kHz. The travelling standard has not been damaged and has shown excellent stability. The results submitted by the overwhelming majority of the participants lie well within the reported uncertainty. At the standard frequencies the results have been linked to those of the CCEM-K6a key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. KEY COMPARISON: Results of the APMP Pressure key comparison APMP.M.P-K1c in gas media and gauge mode from 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, A. K.; Woo, Sam Yong; Fitzgerald, Mark; Man, John; Ooiwa, Akira; Jescheck, M.; Jian, Wu; Fatt, Chen Soo; Chan, T. K.; Moore, Ken; El-Tawil, Alaaeldin A. E.

    2003-01-01

    laboratories have primary standards [Category (I)], the remaining five laboratories are placed in Category (II). The obtained data were compiled and processed under the same program as per the Consultative Committee for Mass and Related Quantities (CCM)/BIPM guidelines. From the data of Category (I), we evaluated the APMP reference value as a function of p'/MPa. Then, we estimated the relative difference of the A'p' values with reference to the APMP reference value for all participating laboratories and we observed that they agree well within their expanded uncertainties. We further estimated the effective area at null pressure and at 23°C (A'0/mm2) and the pressure distortion coefficient (lambda'/MPa-1) of the transfer standard for all the participating laboratories. We then estimated the relative deviation of the A'0/mm2 from the reference value for all eleven laboratories and compared this with their estimated expanded uncertainties. The result is once again extremely encouraging and all these eleven laboratories are agreeing within their estimated maximum expanded uncertainties. We also estimated the degree of equivalence between any two participating laboratories following a matrix mechanism. This once again agrees extremely well within the estimated relative standard uncertainty, which is derived for the two participating laboratories. Finally, a new method has been introduced to evaluate these results and establish a link to CCM.P-K1c and EUROMET.M.P-K2 at two nominal pressures, near 1 MPa and 4 MPa. Again the results show an agreement of all participating laboratories in the present comparison to within the estimated expanded uncertainties using a coverage factor k = 2. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the Mutual

  12. Final report on key comparison CCAUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Avison, Janine; Barham, Richard

    2014-01-01

    This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Reference-frame-independent quantum-key-distribution server with a telecom tether for an on-chip client.

    PubMed

    Zhang, P; Aungskunsiri, K; Martín-López, E; Wabnig, J; Lobino, M; Nock, R W; Munns, J; Bonneau, D; Jiang, P; Li, H W; Laing, A; Rarity, J G; Niskanen, A O; Thompson, M G; O'Brien, J L

    2014-04-04

    We demonstrate a client-server quantum key distribution (QKD) scheme. Large resources such as laser and detectors are situated at the server side, which is accessible via telecom fiber to a client requiring only an on-chip polarization rotator, which may be integrated into a handheld device. The detrimental effects of unstable fiber birefringence are overcome by employing the reference-frame-independent QKD protocol for polarization qubits in polarization maintaining fiber, where standard QKD protocols fail, as we show for comparison. This opens the way for quantum enhanced secure communications between companies and members of the general public equipped with handheld mobile devices, via telecom-fiber tethering.

  14. Final report on the key comparison CCM.P-K4.2012 in absolute pressure from 1 Pa to 10 kPa

    NASA Astrophysics Data System (ADS)

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Results and evaluation of key comparison CCM.P-K12.1 for very low helium flow rates (leak rates)

    NASA Astrophysics Data System (ADS)

    Šetina, Janez; Vičar, Martin; Pražák, Dominik

    2015-01-01

    The Czech Metrology Institute (CMI) took part and failed to prove equivalence in the Key Comparison CCM.P-K12 of helium leak artefacts (leak rates) into vacuum. After identifying and eliminating the cause of the failure, the Institute of Metals and Technology (IMT) of Slovenia, a successful participant in CCM.P-K12, volunteered to serve as pilot and link in a following bilateral comparison of IMT and CMI that obtained designation CCM.P-K12.1 in June 2012. It was decided to perform the comparison with a glass permeation helium leak artefact at nominally 3.10-11 mol/s (7.4.10-7 mbar.L.s-1) at 23 °C. Both the laboratory standards took part in CCM.P-K12 and were considered as primary. The comparison measurements were performed in October 2012. CMI proved equivalence both with IMT and with the reference value of the key comparison CCM.P-K12. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison

    NASA Astrophysics Data System (ADS)

    Newell, D. B.; van Westrum, D.; Francis, O.; Kanney, J.; Liard, J.; Ramirez, A. E.; Lucero, B.; Ellis, B.; Greco, F.; Pistorio, A.; Reudink, R.; Iacovone, D.; Baccaro, F.; Silliker, J.; Wheeler, R. D.; Falk, R.; Ruelke, A.

    2017-01-01

    Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report on COOMET.AUV.A-S1: Technical report on supplementary comparison 'Comparison of national standards of the sound pressure unit in air through calibration of working reference microphones'

    NASA Astrophysics Data System (ADS)

    Pozdeeva, Valentina; Chalyy, Vladimir

    2014-01-01

    The supplementary comparison COOMET.AUV.A-S1 for secondary calibration methods using WS1 and WS2 measurement microphones was carried out from 2009 to 2010. The results were submitted to and approved by CCAUV in April 2014. Four National Metrology Institutes took part in this comparison and are as follows: BelGIM (Belarus), VNIIFTRI (Russia), SMU (Slovakia) and DP NDI 'Sistema' (Ukraine). Three of the above NMIs (VNIIFTRI, SMU and DP NDI 'Sistema') had earlier participated in COOMET key comparisons and one NMI (VNIIFTRI) had also participated in CCAUV key comparisons. The Comparison Reference Values were calculated as the weighted mean values from results obtained by three institutes. The comparison results show agreement for all participants in the frequency range from 20 Hz to 12.5 kHz for WS1 microphones, and in the frequency range from 20 Hz to 16 kHz for WS2 microphones. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in January and February 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM7 (Z7) and BIPM9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V, at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 31 of January 2016. UNML - UBIPM = + 0.22 μV uc = 1.35 μV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Power, O.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in February and March 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMC (ZC), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final resultof the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V,at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 24 February 2015. UNML - UBIPM = - 0.82 mV; uc = 1.35 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out in February and March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_4 (Z4) and BIPM_5 (Z5), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 10 March 2014. UNML - UBIPM = -0.64 µV uc = 1.35 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to

  1. Report of the key-comparison of spectral diffuse reflectance (EURAMET.PR-K5) (Ref. 619)

    NASA Astrophysics Data System (ADS)

    Andor, György; Gál, Péter

    2018-01-01

    This report details the final results of the EURAMET comparison on regular spectral transmittance carried out between 2006 and 2016. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 780 nm at 20 nm increment. We used a star type comparison: first the participants sent their samples to the pilot, than the pilot measured all the samples of the participants and sent them back. The participants measured the samples and sent them to the pilot for control measurement. Six standards were used as reference standards in order to maintain the scale during the comparison. These were three samples of BCR-406 opal glasses (BCR 30506; BCR 30303; BCR 30704), an MC20 Russian opal glass (MC 4777) and two samples made of pressed halon (polytetrafluoroethylene) powder (halon 2007A; halon 2007C). These six samples were designated as the Comparison reference standards. The diffuse reflectance was initially measured on the OMH (BFKH) absolute reflectometer. The link to the CCPR-K5 results was BFKH, and the check on BFKH was the PTB results who also participated in the CCPR-K5 comparison. The participants were GUM, INM, LNE, METAS, BFKH, PTB, SP. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. KEY COMPARISON: Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Kurupakorn, C.; Fletcher, N.; Stock, M.

    2010-01-01

    This report describes the results obtained from a NIMT (Thailand)-BIPM bilateral comparison of 10 kΩ resistance standards in 2009. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMIT and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was smaller than the uncertainty arising from the calibrations. The mean difference between the NIMT and the BIPM calibrations was found to be significantly larger than the expanded uncertainty (k = 2) of the comparison. However, this exercise allowed previously undetected sources of errors to be detected in the NIMT facility. A new bilateral comparison can be organized as soon as these problems are fixed. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Final report on SIM Regional Key Comparison SIM.L-K1.2007: Calibration of gauge blocks by optical interferometry

    NASA Astrophysics Data System (ADS)

    Colín, C.; Viliesid, M.; Chaudhary, K. P.; Decker, J.; Dvorácek, F.; Franca, R.; Ilieff, S.; Rodríguez, J.; Stoup, J.

    2012-01-01

    This Key Comparison of gauge blocks (GB) calibration by optical interferometry was carried out to support this Calibration and Measurement Capability (CMC) of the National Measurement Institutes (NMI) from the SIM Region for this specific service and for those that rely on this kind of technique as required by the Mutual Recognition Arrangement (MRA). It provides evidence of the participant's technical competence and supports the uncertainties they state in their CMC. It is a Regional Key Comparison and should be linked to the upper level corresponding comparison CCL-K1. The comparison had nine participants, five from the SIM Region—NRC-CNRC, Canada; NIST, USA; CENAM, Mexico; INMETRO, Brazil; and INTI, Argentina— and four from other regions—CMI, Czech Rep.; CEM, Spain; NPLI, India; and NMISA South Africa. It included the circulation of fourteen GB—seven steel GB and seven ceramic GB. The circulation of the artifacts started on 2007-11-01 and ended on 2010-04-25. Some additional time was required to publish the results as the same artifacts were used thereafter for comparison SIM.L-S6, Calibration of GB by mechanical comparison, and the results could not be disclosed until the participants of the second circulation loop had sent their results. The final report of this comparison was sent out for review in May 2012 and the final version was approved in August 2012. The behavior of the artifacts throughout the circulation was good and therefore the results obtained were judged technically valid. The reference value was taken as arithmetic mean of the largest subset of consistent results. Most of participates obtained results in good agreement with the reference values with a few exceptions mentioned in the report. The corresponding NMIs are responsible for identifying the causes and taking corrective action. This makes the present comparison exercise valid to support the CMC claims of the participants in GB calibration by optical interferometry. Main text. To

  4. Final report on the key comparison of hydrocarbon liquid flow: CCM.FF-K2.2015

    NASA Astrophysics Data System (ADS)

    Shimada, T.; Bittner-Rohrhofer, K.; Medina López, V. J.; Arias, R.; Su, C.-M.; Chen, I.-C.; Ribere, F.; Rowan, L.; Dignan, S.

    2016-01-01

    Seven laboratories: BEV (Austria), CENAM (Mexico), CMS (Chinese-Taipei), LNE-TRAPIL (France), NEL (United Kingdom), NMIA (Australia), and the pilot lab NMIJ (Japan), participated in the key comparison CCM.FF-K2.2015 for hydrocarbon flow measurement. A screw type positive displacement flow meter was selected as a transfer standard. The calibration stability of the transfer standard was evaluated from repeated measurements by NMIJ and showed standard reproducibility of 0.0035 %. The transfer standard was also thoroughly tested for sensitivity to temperature, viscosity, pressure, and other effects. The uncertainty due to the transfer standard of 0.0080 % was less than the quoted uncertainties of the participants. The key comparison reference values (KCRVs) at Reynolds number of 70 000 and 300 000 were obtained as the weighted mean from the calibration results, and the KCRV at Reynolds number of 100 000 was obtained as the median by using the Monte Carlo method according to Cox's procedure B, since the consistency check at Reynolds number of 100 000 failed at the 95 % confidence level. All participant results selected to determine the KCRVs have En values which show consistency with the evaluated KCRVs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Final report of the regional key comparison EURAMET.M.G-K1: European Comparison of Absolute Gravimeters ECAG-2011

    NASA Astrophysics Data System (ADS)

    Francis, Olivier; Klein, Gilbert; Baumann, Henri; Dando, Nicolas; Tracey, Ray; Ullrich, Christian; Castelein, Stefaan; Hua, Hu; Kang, Wu; Chongyang, Shen; Songbo, Xuan; Hongbo, Tan; Zhengyuan, Li; Pálinkás, Vojtech; Kostelecký, Jakub; Mäkinen, Jaakko; Näränen, Jyri; Merlet, Sébastien; Farah, Tristan; Guerlin, Christine; Pereira Dos Santos, Franck; Le Moigne, Nicolas; Champollion, Cédric; Deville, Sabrina; Timmen, Ludger; Falk, Reinhard; Wilmes, Herbert; Iacovone, Domenico; Baccaro, Francesco; Germak, Alessandro; Biolcati, Emanuele; Krynski, Jan; Sekowski, Marcin; Olszak, Tomasz; Pachuta, Andrzej; Agren, Jonas; Engfeldt, Andreas; Reudink, René; Inacio, Pedro; McLaughlin, Daniel; Shannon, Geoff; Eckl, Marc; Wilkins, Tim; van Westrum, Derek; Billson, Ryan

    2012-01-01

    During November 2011 a EURAMET key comparison of absolute gravimeters was organized in the Underground Laboratory for Geodynamics in Walferdange, Luxemburg. The comparison assembled 22 participants coming from 16 countries and four different continents. The comparison was divided into two parts: a key comparison that included six National Metrology Institutes or Designated Institutes, and a pilot study including all participants. The global result given by the pilot study confirms that all instruments are absolutely coherent with each other. The results obtained in the key comparison confirm a good agreement between the NMI instruments. Finally, a link to ICAG-2009 shows also that the NMI gravimeters are stable in time. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Chayramy, R.; Solve, S.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from January to February 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_8 (Z8) and BIPM_9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 February 2013. UNML - UBIPM = -0.63 µV uc = 1.31 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according

  7. Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.; Rujirat, N.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device. Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 2.6 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on key comparison APMP.M.P-K13 in hydraulic gauge pressure from 50 MPa to 500 MPa

    NASA Astrophysics Data System (ADS)

    Kajikawa, Hiroaki; Kobata, Tokihiko; Yadav, Sanjay; Jian, Wu; Changpan, Tawat; Owen, Neville; Yanhua, Li; Hung, Chen-Chuan; Ginanjar, Gigin; Choi, In-Mook

    2015-01-01

    This report describes the results of a key comparison of hydraulic high-pressure standards at nine National Metrology Institutes (NMIs: NMIJ/AIST, NPLI, NMC/A*STAR, NIMT, NMIA, NIM, CMS/ITRI, KIM-LIPI, and KRISS) within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence in the pressure range from 50 MPa to 500 MPa in gauge mode. The pilot institute was the National Metrology Institute of Japan (NMIJ/AIST). All participating institutes used hydraulic pressure balances as their pressure standards. A set of pressure balance with a free-deformational piston-cylinder assembly was used as the transfer standard. Three piston-cylinder assemblies, only one at a time, were used to complete the measurements in the period from November 2010 to January 2013. Ten participants completed their measurements and reported the pressure-dependent effective areas of the transfer standard at specified pressures with the associated uncertainties. Since one of the participants withdrew its results, the measurement results of the nine participants were finally compared. The results were linked to the CCM.P-K13 reference values through the results of two linking laboratories, NMIJ/AIST and NPLI. The degrees of equivalence were evaluated by the relative deviations of the participants' results from the CCM.P-K13 key comparison reference values, and their associated combined expanded (k=2) uncertainties. The results of all the nine participating NMIs agree with the CCM.P-K13 reference values within their expanded (k=2) uncertainties in the entire pressure range from 50 MPa to 500 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Report on key comparison COOMET.AUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Dobrowolska, D.; Kosterov, A.

    2016-01-01

    This is the final report for regional key comparison COOMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Two laboratories—Central Office of Measures (GUM)—the national metrology institute for Poland and the State Enterprise Scientific-Research Institute for Metrology of Measurement and Control Systems (DP NDI Systema)— the designated institute for acoustics in Ukraine took part in this comparison with the GUM as a pilot. One travelling type LS1P microphone was circulated to the participants and results in the form of regular calibration certificates were collected. The results of the DP NDI Systema obtained in this comparison were linked to the CCAUV.A-K5 key comparison through the joint participation of the GUM. The degrees of equivalence were computed for DP NDI Systema with respect to the CCAUV.A-K5 key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Two-dimensional distributed-phase-reference protocol for quantum key distribution

    NASA Astrophysics Data System (ADS)

    Bacco, Davide; Christensen, Jesper Bjerge; Castaneda, Mario A. Usuga; Ding, Yunhong; Forchhammer, Søren; Rottwitt, Karsten; Oxenløwe, Leif Katsuo

    2016-12-01

    Quantum key distribution (QKD) and quantum communication enable the secure exchange of information between remote parties. Currently, the distributed-phase-reference (DPR) protocols, which are based on weak coherent pulses, are among the most practical solutions for long-range QKD. During the last 10 years, long-distance fiber-based DPR systems have been successfully demonstrated, although fundamental obstacles such as intrinsic channel losses limit their performance. Here, we introduce the first two-dimensional DPR-QKD protocol in which information is encoded in the time and phase of weak coherent pulses. The ability of extracting two bits of information per detection event, enables a higher secret key rate in specific realistic network scenarios. Moreover, despite the use of more dimensions, the proposed protocol remains simple, practical, and fully integrable.

  11. Two-dimensional distributed-phase-reference protocol for quantum key distribution.

    PubMed

    Bacco, Davide; Christensen, Jesper Bjerge; Castaneda, Mario A Usuga; Ding, Yunhong; Forchhammer, Søren; Rottwitt, Karsten; Oxenløwe, Leif Katsuo

    2016-12-22

    Quantum key distribution (QKD) and quantum communication enable the secure exchange of information between remote parties. Currently, the distributed-phase-reference (DPR) protocols, which are based on weak coherent pulses, are among the most practical solutions for long-range QKD. During the last 10 years, long-distance fiber-based DPR systems have been successfully demonstrated, although fundamental obstacles such as intrinsic channel losses limit their performance. Here, we introduce the first two-dimensional DPR-QKD protocol in which information is encoded in the time and phase of weak coherent pulses. The ability of extracting two bits of information per detection event, enables a higher secret key rate in specific realistic network scenarios. Moreover, despite the use of more dimensions, the proposed protocol remains simple, practical, and fully integrable.

  12. Two-dimensional distributed-phase-reference protocol for quantum key distribution

    PubMed Central

    Bacco, Davide; Christensen, Jesper Bjerge; Castaneda, Mario A. Usuga; Ding, Yunhong; Forchhammer, Søren; Rottwitt, Karsten; Oxenløwe, Leif Katsuo

    2016-01-01

    Quantum key distribution (QKD) and quantum communication enable the secure exchange of information between remote parties. Currently, the distributed-phase-reference (DPR) protocols, which are based on weak coherent pulses, are among the most practical solutions for long-range QKD. During the last 10 years, long-distance fiber-based DPR systems have been successfully demonstrated, although fundamental obstacles such as intrinsic channel losses limit their performance. Here, we introduce the first two-dimensional DPR-QKD protocol in which information is encoded in the time and phase of weak coherent pulses. The ability of extracting two bits of information per detection event, enables a higher secret key rate in specific realistic network scenarios. Moreover, despite the use of more dimensions, the proposed protocol remains simple, practical, and fully integrable. PMID:28004821

  13. Bilateral key comparison CCM.P-K3.1 for absolute pressure measurements from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Fedchak, J. A.; Bock, Th; Jousten, K.

    2014-01-01

    This report describes the bilateral key comparison CCM.P-K3.1 between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt (PTB) for absolute pressure in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. This comparison was a follow-up to the comparison CCM.P-K3. Two ionization gauges and two spinning rotor gauges (SRGs) were used as the transfer standards for the comparison. The SRGs were used to compare the standards at a pressure of 9 × 10-4 Pa and to normalize the ionization gauge readings. The two ionization gauges were used to compare the standards in the pressure range of from 3 × 10-6 Pa to 3 × 10-4 Pa. Both laboratories used dynamic expansion chambers as standards in the comparison. The two labs showed excellent agreement with each other and with the CCM.P-K3 key comparison reference value (KCRV) over the entire range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report on key comparison EURAMET.M.P-K13 in the range 50 MPa to 500 MPa of hydraulic gauge pressure

    NASA Astrophysics Data System (ADS)

    Kocas, I.; Sabuga, W.; Bergoglio, M.; Eltaweel, A.; Korasie, C.; Farar, P.; Setina, J.; Waller, B.; Durgut, Y.

    2015-01-01

    The regional key comparison EURAMET.M.P-K13 for pressure measurements in liquid media from 50 MPa to 500 MPa was piloted by the TÜBİTAK UME Pressure Group Laboratories, Turkey. The transfer standard was a DH-Budenberg pressure balance with a free deformation piston-cylinder unit of 2 mm2 nominal effective area. Six laboratories from the EURAMET region, namely PTB, INRIM, SMU, IMT, NPL and UME, and two laboratories from the AFRIMETS region, NIS and NMISA participated in this comparison. Participant laboratories and countries are given in the bottom of the page. PTB participated in this comparison to provide a link to corresponding 500 MPa CCM key comparison CCM.P-K13. The results of all participants excepting NMISA and NPL were found to be consistent with the reference value of the actual comparison and of CCM.P-K13 within their claimed uncertainties (k = 2), at all pressures. Compared in pairs all laboratories with exception of NPL and NMISA demonstrate their agreement with each other within the expanded uncertainties (k = 2) at all pressures. The results are therefore considered to be satisfactory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2012-01-01

    As part of the on-going BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from February to March 2012. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_C (ZC) and BIPM_D (ZD), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson voltage standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 February 2012. UNML - UBIPM = +0.83 µV, uc = 1.35 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. The final result is impacted by the anomalous offset between the NSAI-NML results for the two transfer standards. The reason for this offset hasn't been determined. However, the difference remains within the total combined standard uncertainty. Therefore, the comparison result shows that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of

  16. Comparison of the Josephson Voltage Standards of the DMDM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Cincar Vujovic, T.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Directorate of Measures and Precious Metals (DMDM), Belgrade, Serbia, was carried out in June 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the DMDM using its Josephson standard with its own measuring device. Option A required the DMDM to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. Since no sufficiently stable voltage could be achieved in this configuration, a digital detector was used. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 1.5 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. KEY COMPARISON: CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    NASA Astrophysics Data System (ADS)

    Hill, K. D.; Steele, A. G.; Dedikov, Y. A.; Shkraba, V. T.

    2005-01-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 Ω capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L&N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions

  18. The comparison and analysis of extracting video key frame

    NASA Astrophysics Data System (ADS)

    Ouyang, S. Z.; Zhong, L.; Luo, R. Q.

    2018-05-01

    Video key frame extraction is an important part of the large data processing. Based on the previous work in key frame extraction, we summarized four important key frame extraction algorithms, and these methods are largely developed by comparing the differences between each of two frames. If the difference exceeds a threshold value, take the corresponding frame as two different keyframes. After the research, the key frame extraction based on the amount of mutual trust is proposed, the introduction of information entropy, by selecting the appropriate threshold values into the initial class, and finally take a similar mean mutual information as a candidate key frame. On this paper, several algorithms is used to extract the key frame of tunnel traffic videos. Then, with the analysis to the experimental results and comparisons between the pros and cons of these algorithms, the basis of practical applications is well provided.

  19. APMP key comparison for the measurement of air kerma for 60Co (APMP.RI(I)-K1.1)

    NASA Astrophysics Data System (ADS)

    Webb, D. V.; Lee, J.-H.; Budiantari, C. T.; Laban, J.; Saito, N.; Srimanoroth, S.; Khaled, N. E.

    2016-01-01

    The results are reported for an APMP.R(I)-K1.1 comparison that extends the regional comparison of standards for air kerma APMP.R(I)-K1 to several laboratories unable to participate earlier. The comparison was conducted with the goal of supporting the relevant calibration and measurement capabilities (CMCs) planned for publication by the participant laboratories. The comparison was conducted by the pilot laboratory, the Australian Radiation Protection and Nuclear Safety (ARPANSA), Australia, supported by the Institute of Nuclear Energy Research (INER), Taiwan, in a modified ring-shaped arrangement from September 2009 to November 2010, in parallel with an APMP.R(I)-K4 comparison being piloted by the INER. The laboratories that took part in the comparison were the ARPANSA, the Centre of Technology of Radiation Safety and Metrology (PTKMR-BATAN), Indonesia, the Division of Radiation and Medical Devices (DMSC), Thailand, the INER, the National Centre for Radiation Science (NCRS), New Zealand, the National Institute for Standards (NIS), Egypt and the National Metrology Institute of Japan (NMIJ/AIST), Japan. The two primary laboratories, ARPANSA and NMIJ, were chosen as the linking laboratories. Three ionization chambers were used as transfer instruments to be calibrated in terms of air kerma in 60Co radiotherapy beams. The comparison result is based on the ratio between the air kerma calibration coefficients (NK) determined by the participants and the mean of the results of the linking laboratories. The mean comparison ratio was found to be within 0.5 % of the key comparison reference value KCRV. The largest deviation between any two comparison ratios for the three chambers in terms of air kerma was 2.0 %. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE) in terms of the deviations of the results and their associated uncertainties. As a result of this APMP comparison, the BIPM key comparison database (KCDB) should

  20. Final report of the key comparison CCQM-K106: Pb, As and Hg measurements in cosmetic (cream)

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Wang, Qian; Yamani, Randa Nasr Ahmed; Shehata, Adel B.; Jacimovic, Radojko; Pavlin, Majda; Horvat, Milena; Tsoi, Y. P.; Tsang, C. K.; Shin, Richard; Chailap, Benjamat; Yafa, Charun; Caciano de Sena, Rodrigo; de Almeida, Marcelo; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Heun Kim, Sook; Konopelko, Leonid; Ari, Betül; Tokman, Nilgün; Rienitz, Olaf; Jaehrling, Reinhard; Pape, Carola

    2015-01-01

    relating to CCQM-K106 was sent to each participant by e-mail, which consisted of technical protocol, results report form and inorganic core capabilities tables. The results were reported as mass faction (mg/kg). Calculation of the uncertainty expressed as a combined standard uncertainty and an expanded uncertainty at 95% confidence. In order to allow a sufficient evaluation of the comparison, the report was required to include a detailed description of the applied method of measurement, information about sample digestion and preparation, information about the reference material used for calibration. The methods of measurement were free to be selected by the participants. For the sample treatment, most of the participants used microwave digestion method. For instrumental determination, a variety of techniques such as ICP-MS, AAS, INAA were adopted by the participants. Most participants choose ID-ICP-MS method to measure Pb and Hg, which showed the better performance in terms of consistency and reliability of the measurement results. The reference mass fraction values and associated uncertainties were calculated by different statistic ways. As the result, the median and uncertainty of median were proposed as the key comparison reference value (KCRV) and its associated key comparison reference uncertainty after removal of suspected extreme values. In general, the performances of the majority of the CCQM-K106 participants are excellent, illustrating their measurement capability for Pb, As and Hg in a complex greasy matrix. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that

  1. Bilateral comparison of 1 V and 10 V standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Simionescu, M.; Cîrneanu, L.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Institut National de Metrologie (INM), Bucharest, Romania, was carried out from August to October 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_8 (Z8), were transported by freight to INM. At INM, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at INM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by INM, at the level of 1.018 V and 10 V, at INM, UINM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 6 September 2013. UINM - UBIPM = -0.014 µV uc = 0.051 µV, at 1 V UINM - UBIPM = -0.43 µV uc = 0.34 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at INM, based on KJ-90, and the uncertainty related to the comparison. These are satisfactory results. The comparison results show that the voltage standards maintained by INM and the BIPM were equivalent, within the comparison uncertainty, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual

  2. KEY COMPARISON Update of the BIPM.RI(II)-K1.Tc-99m comparison of activity measurements for the radionuclide 99mTc to include new results for the LNE-LNHB and the NPL

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Moune, M.; Johansson, L.; Keightley, J.

    2010-01-01

    In 2007 and 2008 respectively, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of 99mTc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNHB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2011-01-01

    As a part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2011. Two BIPM Zener diode-based travelling standards (Fluke 732B) were transported by freight to NSAI-NML. At NSAI-NML, the 10 V output EMF of each travelling standard was measured by direct comparison with a group of characterized Zener diode-based electronic voltage standards. At the BIPM, the travelling standards were calibrated before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. Phase-encoded measurement device independent quantum key distribution without a shared reference frame

    NASA Astrophysics Data System (ADS)

    Zhuo-Dan, Zhu; Shang-Hong, Zhao; Chen, Dong; Ying, Sun

    2018-07-01

    In this paper, a phase-encoded measurement device independent quantum key distribution (MDI-QKD) protocol without a shared reference frame is presented, which can generate secure keys between two parties while the quantum channel or interferometer introduces an unknown and slowly time-varying phase. The corresponding secret key rate and single photons bit error rate is analysed, respectively, with single photons source (SPS) and weak coherent source (WCS), taking finite-key analysis into account. The numerical simulations show that the modified phase-encoded MDI-QKD protocol has apparent superiority both in maximal secure transmission distance and key generation rate while possessing the improved robustness and practical security in the high-speed case. Moreover, the rejection of the frame-calibrating part will intrinsically reduce the consumption of resources as well as the potential security flaws of practical MDI-QKD systems.

  5. Bilateral Comparison of 1 V and 10 V Standards between the SMD (Belgium) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Vlad, D.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Service Métrologie—Metrologische Dienst (SMD), Brussel, Belgium, was carried out from October to November 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to SMD and also back to BIPM. At SMD, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at SMD, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by SMD, at the level of 1.018 V and 10 V, at SMD, USMD, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 November 2014. USMD - UBIPM = 0.14 mV; uc = 0.07 mV, at 1 V USMD - UBIPM = 0.09 mV; uc = 0.49 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at SMD, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Bilateral Comparison of 1 V and 10 V Standards between the JV (Norway) and the BIPM, January to February 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Sengebush, F.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Justervesenet (JV), Kjeller, Norway, was carried out from January to February 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to JV and also back to BIPM. At JV, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at JV, withthe Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by JV, at the level of 1.018 V and 10 V, at JV, UJV, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 28 January 2015. UJV - UBIPM = 0.23 μV uc = 0.03 μV , at 1 V UJV - UBIPM = 0.63 μV uc = 0.28 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at JV, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Bilateral Comparison of 1 V and 10 V Standards between the NIMT (Thailand) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute of Metrology (Thailand), NIMT, was carried out from October to December 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPM6 (Z6), were transported by freight to NIMT and back to BIPM. At NIMT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIMT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by NIMT, at the level of 1.018 V and 10 V, at NIMT, UNIMT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 November 2014. UNIMT - UBIPM = 0.16 mV; uc = 0.14 mV, at 1 V UNIMT - UBIPM = - 0.03 mV; uc = 0.11 mV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIMT, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    NASA Astrophysics Data System (ADS)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of

  9. Proof-of-principle experiment of reference-frame-independent quantum key distribution with phase coding

    PubMed Central

    Liang, Wen-Ye; Wang, Shuang; Li, Hong-Wei; Yin, Zhen-Qiang; Chen, Wei; Yao, Yao; Huang, Jing-Zheng; Guo, Guang-Can; Han, Zheng-Fu

    2014-01-01

    We have demonstrated a proof-of-principle experiment of reference-frame-independent phase coding quantum key distribution (RFI-QKD) over an 80-km optical fiber. After considering the finite-key bound, we still achieve a distance of 50 km. In this scenario, the phases of the basis states are related by a slowly time-varying transformation. Furthermore, we developed and realized a new decoy state method for RFI-QKD systems with weak coherent sources to counteract the photon-number-splitting attack. With the help of a reference-frame-independent protocol and a Michelson interferometer with Faraday rotator mirrors, our system is rendered immune to the slow phase changes of the interferometer and the polarization disturbances of the channel, making the procedure very robust. PMID:24402550

  10. Bilateral Comparison of 1 V and 10 V Standards between the NIS (Egypt) and the BIPM, August to September 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Abdel Mageed, Hala M.; Aladdin, Omar M.; Raouf, M. Helmy A.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMB (ZB) and BIPMC (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, UNIS, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 7 September 2014. UNIS - UBIPM = 0.09 µV uc = 0.08 µV, at 1 V UNIS - UBIPM = 0.22 µV uc = 0.14 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM

  11. Reference Standards, Judges, and Comparison Subjects

    PubMed Central

    Hripcsak, George; Wilcox, Adam

    2002-01-01

    Medical informatics systems are often designed to perform at the level of human experts. Evaluation of the performance of these systems is often constrained by lack of reference standards, either because the appropriate response is not known or because no simple appropriate response exists. Even when performance can be assessed, it is not always clear whether the performance is sufficient or reasonable. These challenges can be addressed if an evaluator enlists the help of clinical domain experts. 1) The experts can carry out the same tasks as the system, and then their responses can be combined to generate a reference standard. 2)The experts can judge the appropriateness of system output directly. 3) The experts can serve as comparison subjects with which the system can be compared. These are separate roles that have different implications for study design, metrics, and issues of reliability and validity. Diagrams help delineate the roles of experts in complex study designs. PMID:11751799

  12. KEY COMPARISON: CCQM-K27-Subsequent: Key Comparison (subsequent) for the determination of ethanol in aqueous matrix

    NASA Astrophysics Data System (ADS)

    Schantz, Michele M.; Duewer, David L.; Parris, Reenie M.; May, Willie E.; Archer, Marcellé; Mussell, Chris; Carter, David; Konopelko, Leonid A.; Kustikov, Yury A.; Krylov, Anatoli I.; Fatina, Olga V.

    2005-01-01

    Ethanol is important both forensically ('drunk driving' or driving while under the influence, 'DWI', regulations) and commercially (alcoholic beverages). Blood- and breath-alcohol testing can be imposed on individuals operating private vehicles such as cars, boats, or snowmobiles, or operators of commercial vehicles like trucks, planes, and ships. The various levels of blood alcohol that determine whether these operators are considered legally impaired vary depending on the circumstances and locality. Accurate calibration and validation of instrumentation is critical in areas of forensic testing where quantitative analysis directly affects the outcome of criminal prosecutions, as is the case with the determination of ethanol in blood and breath. Additionally, the accurate assessment of the alcoholic content of beverages is a commercially important commodity. In 2002, the CCQM conducted a Key Comparison (CCQM-K27) for the determination of ethanol in aqueous matrix with nine participants. A report on this project has been approved by the CCQM and can be found at the BIPM website and in this Technical Supplement. CCQM-K27 comprised three samples, one at low mass fraction of ethanol in water (nominal concentration of 0.8 mg/g), one at high level (nominal concentration of 120 mg/g), and one wine matrix (nominal concentration of 81 mg/g). Overall agreement among eight participants using gas chromatography with flame ionization detection (GC-FID), titrimetry, isotope dilution gas chromatography/mass spectrometry (GC-IDMS), and gas chromatography-combustion-isotope ratio mass spectrometry (ID-GC-C-IRMS) was good. The ninth participant used a headspace GC-FID method that had not been validated in an earlier pilot study (CCQM-P35). A follow-on Key Comparison, CCQM-K27-Subsequent, was initiated in 2003 to accommodate laboratories that had not been ready to benchmark their methods in the original CCQM-K27 study or that wished to benchmark a different method. Four levels of

  13. Report of the key comparison APMP.QM-K19. APMP comparison on pH measurement of borate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Obromsook, Krairerk; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Wong, Siu-Kay; Lam, Wai-Hing; Zakaria, Osman; Anuar Mohd. Amin, Khirul; Thanh, Ngo Huy; Máriássy, Michal; Vyskocil, Leos; Hankova, Zuzana; Fisicaro, Paola; Stoica, Daniela; Singh, Nahar; Soni, Daya; Ticona Canaza, Galia; Kutovoy, Viatcheslav; Barbieri Gonzaga, Fabiano; Dias, Júlio Cesar; Vospelova, Alena; Bakovets, Nickolay; Zhanasbayeva, Bibinur

    2015-01-01

    The APMP.QM-K19 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a borate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan (NMIJ) and the National Institute of Metrology (Thailand) (NIMT) at the APMP-TCQM meeting held 26-27 November 2012. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K19 and CCQM-K19.1. The comparison material was a borate buffer of pH around 9.2 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the second APMP key comparison on pH measurement and the fourth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006 and APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. CCM.FF-K3.2011: Final report for the CIPM key comparison of air speed, 0.5 m/s to 40 m/s

    NASA Astrophysics Data System (ADS)

    Müller, Harald; Caré, Isabelle; Lucas, Peter; Pachinger, Dietmar; Kurihara, Noboru; Lishui, Cui; Su, Chun-Min; Shinder, Iosif; Spazzini, Pier Giorgio

    2017-01-01

    The CCM.FF-K3.2011 comparison was organized for the purpose of determination of the degree of equivalence of the national standards for air speed over the range 0.5 m/s to 40 m/s. An ultrasonic anemometer and a Laser Doppler anemometer were used as transfer standards. Nine laboratories from three RMOs participated between July 2013 and July 2015—EURAMET: PTB, Germany; LNE-CETIAT, France; INRIM, Italy; VSL, The Netherlands; E+E, Austria; SIM: NIST, USA; APMP: NMIJ/AIST, Japan; NIM, China; CMS/ITRI, Chinese Taipei. The measurements were provided at ambient conditions. All results of independent participants were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each air speed separately following `procedure A' presented by M G Cox. The degree of equivalence with the KCRV was calculated for each air speed and laboratory. Almost all reported results were consistent with the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Regional comparison of absolute gravimeters, EURAMET.M.G-K2 key comparison

    NASA Astrophysics Data System (ADS)

    Pálinkáš, V.; Francis, O.; Val'ko, M.; Kostelecký, J.; Van Camp, M.; Castelein, S.; Bilker-Koivula, M.; Näränen, J.; Lothhammer, A.; Falk, R.; Schilling, M.; Timmen, L.; Iacovone, D.; Baccaro, F.; Germak, A.; Biolcati, E.; Origlia, C.; Greco, F.; Pistorio, A.; De Plaen, R.; Klein, G.; Seil, M.; Radinovic, R.; Reudink, R.; Dykowski, P.; Sȩkowski, M.; Próchniewicz, D.; Szpunar, R.; Mojzeš, M.; Jańk, J.; Papčo, J.; Engfeldt, A.; Olsson, P. A.; Smith, V.; van Westrum, D.; Ellis, B.; Lucero, B.

    2017-01-01

    In the framework of the regional EURAMET.M.G-K2 comparison of absolute gravimeters, 17 gravimeters were compared in November 2015. Four gravimeters were from different NMIs and DIs, they were used to link the regional comparison to the CCM.G.K2 by means of linking converter. Combined least-squares adjustments with weighted constraint was used to determine KCRV. Several pilot solutions are presented and compared with the official solution to demonstrate influences of different approaches (e.g. definition of weights and the constraint) on results of the adjustment. In case of the official solution, all the gravimeters are in equivalence with declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. KEY COMPARISON: Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Giera, Janine; Fraga, Isabel C.; Tønnes Jakobsen, Pia; Jensen, Hans D.; Hyllested, Peter; Karpov, Oleg; Kutovoy, Viatcheslav; Nakamura, Susumu; Vospelova, Alena; Zvezdina, Valentina

    2008-01-01

    CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were 15 °C, 25 °C, 37 °C. CCQM-K9.2, CCQM-K.9 and the first supplementary comparison CCQM-K9.1 [5] are activities of the Electrochemical Working Group (EAWG) of the CCQM. All three comparisons were coordinated by the PTB, Germany. The Danish Primary Laboratory (DPL) successfully took part in the CCQM-K9. Meanwhile the primary set-up for pH in Denmark moved from DPL affiliated to Radiometer Medical to DFM, Denmark. The subsequent comparison allows assessing the degree of equivalence for the measurement of pH at DFM after the move. Due to the interest of other laboratories in demonstrating their progress in pH measurements on the primary level the CCQM-K9.2 supplementary comparison was extended to other participants than DFM, namely NMIJ, VNIIFTRI, INMETRO and CMI. The reported quantity for CCQM-K9.2 was not the pH of the sample but the acidity function at zero chloride molality (see chapter 12). To calculate the pH value from the acidity function it is necessary to know the ionic strength of the sample buffer solution, which was undisclosed by the coordinator. With the exception of the Czech Metrology Institute, CMI, good agreement in the determined acidity function is found between the participants. The results reported by DFM and by PTB agree within their measurement uncertainty at all measurement temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report

  17. Reference-Frame-Independent and Measurement-Device-Independent Quantum Key Distribution Using One Single Source

    NASA Astrophysics Data System (ADS)

    Li, Qian; Zhu, Changhua; Ma, Shuquan; Wei, Kejin; Pei, Changxing

    2018-04-01

    Measurement-device-independent quantum key distribution (MDI-QKD) is immune to all detector side-channel attacks. However, practical implementations of MDI-QKD, which require two-photon interferences from separated independent single-photon sources and a nontrivial reference alignment procedure, are still challenging with current technologies. Here, we propose a scheme that significantly reduces the experimental complexity of two-photon interferences and eliminates reference frame alignment by the combination of plug-and-play and reference frame independent MDI-QKD. Simulation results show that the secure communication distance can be up to 219 km in the finite-data case and the scheme has good potential for practical MDI-QKD systems.

  18. Final report of the key comparison APMP.QM-K91: APMP comparison on pH measurement of phthalate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Ketrin, Rosi; Nuryatini; Thanh, Ngo Huy; Truong Chinh, Nguyen; Vospelova, Alena; Bastkowski, Frank; Sander, Beatrice; Matzke, Jessica; Prokunin, Sergey; Frolov, Dmitry; Aprelev, Alexey; Dobrovolskiy, Vladimir; Uysal, Emrah; Liv, Lokman; Velina Lara-Manzano, Judith; Montero-Ruiz, Jazmin; Ortiz-Aparicio, JosÉ Luis; Ticona Canaza, Galia; Anuar Mohd Amin, Khirul; Abd Kadir, Haslina; Bakovets, Nickolay; Wong, Siu-Kay; Lam, Wai-Hing

    2017-01-01

    The APMP.QM-K91 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phthalate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan at the APMP-TCQM meeting held September 22-23, 2014. After approval by TCQM, the comparison has been conducted by NMIJ. The comparison is a key comparison following CCQM-K91. The comparison material was a phthalate buffer of pH around 4.0 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the third APMP key comparison on pH measurement and the fifth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006, APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011 and APMP.QM-K19/APMP.QM-P25 (a borate buffer) in 2013-2014. The results can be used further by any participant to support its CMC claim at least for a phthalate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report of the key comparison APMP.QM-K9: APMP comparison on pH measurement of phosphate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Ohata, Masaki; Cherdchu, Chainarong; Tangpaisarnkul, Nongluck

    2011-01-01

    The APMP.QM-K9 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phosphate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan, NMIJ, and the National Institute of Metrology of Thailand, NIMT, in August 2009. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K9, CCQM-K9.1 and CCQM-K9.2. The comparison material was a phosphate buffer of pH around 6.86 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the first APMP key comparison on pH measurement and the third APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004 and APMP.QM-P09 (a phthalate buffer) in 2006. The results can be used further by any participant to support its CMC claim for a phosphate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the temperature(s) used or the full temperature range between 15 °C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. CCQM-K104 key comparison (avermectin B1a) on the characterization of organic substances for chemical purity

    NASA Astrophysics Data System (ADS)

    Dai, Xinhua; Zhang, Wei; Li, Hongmei; Huang, Ting; Li, Mengwan; Quan, Can; Zhang, Qinghe; Davies, Stephen R.; Warren, John; Lo, Man-fung; Kakoulides, Elias; Ceyhan Gören, Ahmet; Marbumrung, Sornkrit; Pfeifer, Dietmar; Ün, İlker; Gündüz, Simay; Yilmaz, Hasibe; Kankaew, Pornhatai; Sudsiri, Nittaya; Shearman, Kittiya; Pookrod, Preeyaporn; Polzer, Joachim; Radeck, Wolfgang

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K104, was coordinated by the National Institute of Metrology (NIM). The comparison was designed to demonstrate a laboratory's performance in determining the mass fraction of the main component in a complex high purity organic material. Nine NMIs or DIs participated in the comparison. Eight participants reported their results. An additional impurity was resolved from the avermectin B1a peak and was tentatively identified as an unknown impurity by NMIA (National Measurement Institute (Australia)). It was subsequently identified by NIM as a diastereoisomer of avermectin B1a at the C-26 position. Final reference value (KCRV) = 924.63 mg/g, with uncertainty (k=1) = 3.89 mg/g, and expanded uncertainty = 8.97 mg/g. The degrees of equivalence with the avermectin B1a KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of high structural complexity (relative molecular mass range of 500 Da -1000 Da and low polarity (-log KOW <= -2). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Characteristics of precision 1 Ω standard resistors influencing transport behaviour and the uncertainty of key comparisons

    NASA Astrophysics Data System (ADS)

    Jones, G. R.; Pritchard, B. J.; Elmquist, R. E.

    2009-10-01

    National measurement institutes (NMIs) participate in international key comparisons organized by the Bureau International des Poids et Mesures (BIPM), the Regional Metrology Organizations (RMOs) or the Consultative Committees of the Comité International des Poids et Mesures (CIPM) in order to provide evidence of equivalent reference standards and measurement capabilities. The US National Institute of Standards and Technology (NIST) and the National Measurement Institute of Australia (NMIA) have recently examined power loading and several other influences on the value of precision transportable 1 Ω resistors that can increase the uncertainty of key comparisons. We have studied the effects of temperature, barometric pressure, humidity, power loading and heat dissipation in oil on transportable wire-wound 1 Ω resistance standards that are based on different alloys and construction principles. This work focuses on standards manufactured from 1970 through 2000 by the NMIA made of Evanohm alloy and on Thomas-type resistors designed in the 1930s and made of Manganin alloy. We show that the relative standard uncertainty related to transport can be less than 0.01 μΩ Ω-1 when using certain resistors of these two types that are characterized and selected for stability. We describe the characterization process, and relate the environmental influences to the physical design, as well as to the mechanical properties and condition of the standards.

  2. KEY COMPARISON: Final report of comparison of the calibrations of hydrometers for liquid density determination between SIM laboratories: SIM.M.D-K4

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar

    2009-01-01

    This SIM comparison on the calibration of high accuracy hydrometers was carried out within fourteen laboratories in the density range from 600 kg/m3 to 1300 kg/m3 in order to evaluate the degree of equivalence among participant laboratories. This key comparison anticipates the planned key comparison CCM.D-K4, and is intended to be linked with CCM.D-K4 when results are available. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. COOMET.QM-K93 (COOMET 615/RU/13): key comparison in the field of measuring of the ethanol amount fraction in nitrogen (120 μmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Efremova, O. V.; Fatina, O. V.; Orshanskaia, A. A.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.

    2016-01-01

    The relevance of the COOMET.QM-K93 comparison is founded on paying particular attention to reliability of measurements which are performed during the medical examination of drivers of vehicles in order to assess the degree of alcoholic intoxication. Standard gas mixtures of ethanol in nitrogen in cylinders under pressure play a key role in providing metrological assurance of breath-alcohol analyzers. Participating laboratories: VNIIM and Ukrmetrteststandart. This comparison was carried out in 2014-2015. This supplementary comparison supports CMC claims for: ethanol in the range 50-500 μmol/mol in a matrix of either nitrogen or synthetic air. Results: The results are consistent with the reference values. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Bilateral key comparison on luminous flux COOMET.PR-K4.1. final report

    NASA Astrophysics Data System (ADS)

    Huriev, M.; Khlevnoy, B.; Tolstykh, G.; Ivashin, E.; Gorchkova, T.

    2017-01-01

    This report describes an international bilateral key comparison on luminous flux of tungsten lamps between the National Scientific Centre 'Institute of Metrology' (NSC 'IM', Ukraine) and All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI, Russia). The comparison is intended to determine the Degrees of Equivalence (DoE) for NSC 'IM' and the associated expanded uncertainty. VNIIOFI acts as a laboratory, providing the link to the comparison CCPR-K4. The comparison used a set of tungsten incandescent lamps as a transfer standard with a luminous flux of approximately 3800 lm. The determined DoE of NSC 'IM' is -0.94% with an expanded uncertainty (k = 2) of 1.05%. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. KEY COMPARISON: EUROMET.M.D-K4/EUROMET Project 702: Comparison of the calibrations of high-resolution hydrometers for liquid density determinations

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Malengo, A.; Vámossy, C.; Bettin, H.; Toth, H.; do Céu Ferreira, M.; Gosset, A.; Madec, T.; Heinonen, M.; Buchner, C.; Lenard, E.; Spurny, R.; Akcadag, U.; Domostroeva, N.

    2008-01-01

    The main objective of the EUROMET project 702 was to compare the extent of comparability among eleven participating European national metrology institutes (INRIM (IT), OMH (HU), PTB (DE), BEV (AT), IPQ (PT), LNE (FR), MIKES (FI), GUM (PL), SMU (SK), UME (TR) and VNIIM (RU)) in performing calibrations of high-resolution hydrometers for liquid density determination in the range between 600 kg m-3 and 1300 kg m-3. By means of two groups of four similar transfer standards of excellent metrological characteristics, the participating laboratories were initially divided into two groups (petals) linked by the three density laboratories of INRIM, OMH and PTB. The results of the participating laboratories have been analyzed in this report and a good agreement was found between the results provided by most of the participants. These results allowed also determination of the degrees of equivalence of each NMI participating with the EUROMET_key comparison reference values (EU_KCRV); they will provide a basis for the review of the Calibration Measurement Capabilities (CMC) entries on hydrometer calibration, and they allowed the degree of equivalence between pairs of NMIs to be established. The Istitituto Nazionale di Ricerca Metrologica (INRIM), Italy, formerly IMGC-CNR, coordinated the project. Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Bilateral comparison of 1 V and 10 V standards between the DEFNAT (Tunisia) and the BIPM February to March 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Ben Salah, B.; Mallat, A.; Abene, L.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Electrique, DEFNAT (Tunisia), was carried out from February to March 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMC (ZC) and BIPM6 (Z6), were transported by freight to DEFNAT and back to BIPM. In order to keep the Zeners powered during their transportation phase, a BIPM in-house voltage stabiliser was connected in parallel to the internal battery. The voltage stabiliser consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for 10 consecutive days. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DEFNAT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT, UDEFNAT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 26th of February 2016. UDEFNAT - UBIPM = + 0.07 μV uc = 0.04 μV, at 1.018 V UDEFNAT - UBIPM = + 0.38 μV uc = 0.10 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  7. Final report on key comparison APMP.M.P-K3: Absolute pressure measurements in gas from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Yoshida, H.; Arai, K.; Akimichi, H.; Hong, S. S.; Song, H. W.

    2011-01-01

    The results of a key comparison of ultra-high vacuum standards at two national metrology institutes (NMIJ/AIST and KRISS) are reported. This bilateral comparison was carried out from May 2010 to October 2010 within the framework of the Asia-Pacific Metrology Programme (APMP) to determine their degrees of equivalence at pressures in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. The pilot institute was NMIJ/AIST. Two spinning rotor gauges and two hot cathode ionization gauges were used as the transfer standards. NMIJ/AIST used two calibration systems: the dynamic expansion system (NMIJ-DES) and two-stage flow-dividing system (NMIJ-TFS). KRISS used the dynamic expansion system. The transfer standards were sufficiently stable to meet the requirements of the comparison compared with those of previous international comparisons owing to some improvements of the protocol and the transfer standards. The ultra-high vacuum standards of NMIJ/AIST and KRISS were found to be equivalent within their claimed uncertainties in the range from 3 × 10-6 Pa to 9 × 10-5 Pa. The NMIJ-DES results, which have smaller uncertainty than NMIJ-TFS, were transferred to the corresponding CCM key comparison, CCM.P-K3, in the range from 3 × 10-6 Pa to 9 × 10-5 Pa and it is shown that the NMIJ values were equivalent to the CCM key comparison reference value within the claimed uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. International comparison CCQM-K111.1—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capability of preparing Primary Standard gas Mixtures (PSMs), performing the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this subsequent key comparison is classified as a track B key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities for propane under the default scheme. The artefact was a binary mixture of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The result of the participating laboratory is consistent with the key comparison reference value within the respective expanded uncertainties and deviates less than 0.1 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  10. KEY COMPARISON: Final Report on EUROMET.T-K3: Regional key comparison of the realisations of the ITS-90 from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Renaot, E.; Hermier, Y.; Valin, M.; Bonnier, G.

    2007-01-01

    This report presents the results of the EUROMET regional key comparison corresponding to CCT-K3 and covering the temperature range from 83.8058 K (triple point of Ar) to 692.77 K (freezing point of Zn). The comparison involved the six NMIs previously involved in CCT-K3 (BNM-INM/CNAM, SMU, IMGC, NMi-VSL, NPL, PTB) and 18 European national laboratories. The comparison was divided into five different loops coordinated by a co-pilot chosen among the laboratories having participated in the CCT-K3 comparison. BNM-INM/CNAM played the role of pilot in establishing the link between the five loops. In each loop, an artefact in the form of a standard platinum resistance thermometer (SPRT) was circulated among the participant laboratories. In order to have sufficient information about the possible drift of the SPRTs, the co-pilots have performed a calibration over the full temperature range at the beginning and at the end of the loop. Each participant laboratory carried out the measurements in agreement with the protocol. After initial measurements of R(tpw) and successful annealing treatment, each calibration consisted of three measurements of R(t) at each fixed point, in separate realizations. Each measurement was followed by a measurement of R(tpw). The order of fixed points was Zn, Sn, In, Ga, Hg, Ar, but if a fixed point was not available, it was omitted. Values of W(t), and their average value, were calculated. The results were reported to the co-pilot and BNM-INM/CNAM, with uncertainty budgets and other specified data. The results of the comparison were analysed by BNM-INM/CNAM. For the sake of clarity, the results are firstly presented loop by loop. In a second step a EUROMET Reference Value (ERV) taking into account the whole comparison was defined. In order to calculate this ERV advantage was taken of the presence of BNM-INM/CNAM in the five loops; the differences between each laboratory's results and BNM-INM's were considered. The participant laboratories decided

  11. Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Zivkovic, V.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Directorate of Measures and Precious Metals (DMDM), Beograd, Serbia, was carried out from January to March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMA (ZA), were transported by freight to DMDM. At DMDM, the reference standard for DC voltage is a Josephson Voltage Standard. The output electromotive force of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DMDM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DMDM, at the level of 1.018 V and 10 V, at DMDM, UDMDM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 13 February 2014. UDMDM - UBIPM = 0.094 µV uc = 0.072 µV, at 1 V UDMDM - UBIPM = 0.39 µV uc = 0.12 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DMDM, based on KJ-90, and the uncertainty related to the comparison. The results at the 10 V level are not covered by the uncertainties with a coverage factor of 2. After the distribution of the Draft A, the DMDM discovered that the pressure gauge was defective. Some considerations on the correction to apply on the comparison result and the corresponding uncertainties are presented in the report. Nevertheless, the above results fully cover the CMCs of DMDM which are significantly larger. No corrections for temperature and pressure are applied in calibrations for

  12. Bilateral comparison of 1 V and 10 V standards between the NMISA (South Africa) and the BIPM April to June 2017 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Matlejoane, A. M.; Magagula, L.; Stock, M.

    2018-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the National Metrology Institute of South Africa, NMISA (South Africa), was carried out from April to June 2017. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPMB (ZB), were transported by freight to NMISA and back to BIPM. In order to keep the Zeners powered during their transportation phase, a voltage stabilizer developed by BIPM was connected in parallel to the internal battery. It consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for ten consecutive days. At NMISA, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NMISA, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NMISA, at the level of 1.018 V and 10 V, at NMISA, UNMISA, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference dates of the 19th and 18th of May 2017, respectively. UNMISA - UBIPM = + 0.07 μV uc = 0.02 μV, at 1.018 V UNMISA - UBIPM = + 0.001 μV uc = 0.34 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NMISA, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  13. CCQM key comparison CCQM-K75: Determination of toxic metals in algae

    NASA Astrophysics Data System (ADS)

    Shakhashiro, A.; Toervenyi, A.; Gaudino, S.; Rosamilia, S.; Belli, M.; Turk, G. C.

    2011-01-01

    The determination of mass fraction of toxic elements and especially platinum emitted from automobile catalytic converters in the air is a critical factor in assessing air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to toxic elements. Biomonitors, such as lichen and algae, are examples of environmental samples that have been widely used by the scientific community to assess and monitor the level of environmental pollution. For this purpose, the IAEA-450 algae material containing heavy metals and platinum at low level was prepared by IAEA Seibersdorf Laboratories in collaboration with the Italian National Institute for Environmental Protection—ISPRA (former APAT). During the April meeting in 2009 of the Inorganic Analysis Working Group (IAWG) of the CCQM it was agreed to organize a key comparison K75 for Pt and Ni and a parallel pilot study P118 for As, Cd, Cr, Hg, Ni, Pb and Pt using this algae material. The key comparison CCQM-K75 was successfully organized. The participating NMIs demonstrated a high level of measurement capabilities and technical competence in analysing nickel and platinum at a low level of concentration in environmental samples such as algae. The between-laboratories reproducibility standard deviation for nickel and platinum was 1.9% and 3.6% respectively, which reflects an excellent agreement of between-laboratories measurement results. The ratio between the bias and its expanded uncertainty for nickel and platinum was below 2.0 for all reported results except in one case. This study was a practical demonstration of a CCQM comparison to use the 'core-capabilities' utilized by participants as a mean of providing evidence for Calibration and Measurement Capabilities (CMC) claims for Ni and Pt. Based on this CCQM international key comparison, the measurement capability of the NMIs which participated in the CCQM-K75 has been demonstrated directly for determination of Pt and Ni

  14. KEY COMPARISON: Report on the Regional Comparison COOMET.AUV.A-K3

    NASA Astrophysics Data System (ADS)

    Barrera-Figueroa, Salvador; Nielsen, Lars; Rasmussen, Knud

    2007-01-01

    COOMET.AUV.A-K3 is a Regional Comparison that supplements the Key Comparison CCAUV.A-K3 organized by the CCAUV. The participating NMIs are GUM (Poland), INM (Romania), VNIIFTRI (Russia) and DP-NDI 'Systema' (Ukraine). The role of Pilot laboratory was undertaken by DPLADFM (Denmark). The measurements took place between May 2005 and February 2006. The time schedule was organized in a single star configuration. Initially, two LS2aP microphones were circulated. However, a sudden change of sensitivity of one of them forced the inclusion of an additional microphone. Nevertheless, the analysis was performed on all microphones involved. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignation of degrees of equivalence and the link to the CCAUV.A-K3. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. A Novel Real-Time Reference Key Frame Scan Matching Method

    PubMed Central

    Mohamed, Haytham; Moussa, Adel; Elhabiby, Mohamed; El-Sheimy, Naser; Sesay, Abu

    2017-01-01

    Unmanned aerial vehicles represent an effective technology for indoor search and rescue operations. Typically, most indoor missions’ environments would be unknown, unstructured, and/or dynamic. Navigation of UAVs in such environments is addressed by simultaneous localization and mapping approach using either local or global approaches. Both approaches suffer from accumulated errors and high processing time due to the iterative nature of the scan matching method. Moreover, point-to-point scan matching is prone to outlier association processes. This paper proposes a low-cost novel method for 2D real-time scan matching based on a reference key frame (RKF). RKF is a hybrid scan matching technique comprised of feature-to-feature and point-to-point approaches. This algorithm aims at mitigating errors accumulation using the key frame technique, which is inspired from video streaming broadcast process. The algorithm depends on the iterative closest point algorithm during the lack of linear features which is typically exhibited in unstructured environments. The algorithm switches back to the RKF once linear features are detected. To validate and evaluate the algorithm, the mapping performance and time consumption are compared with various algorithms in static and dynamic environments. The performance of the algorithm exhibits promising navigational, mapping results and very short computational time, that indicates the potential use of the new algorithm with real-time systems. PMID:28481285

  16. A Novel Real-Time Reference Key Frame Scan Matching Method.

    PubMed

    Mohamed, Haytham; Moussa, Adel; Elhabiby, Mohamed; El-Sheimy, Naser; Sesay, Abu

    2017-05-07

    Unmanned aerial vehicles represent an effective technology for indoor search and rescue operations. Typically, most indoor missions' environments would be unknown, unstructured, and/or dynamic. Navigation of UAVs in such environments is addressed by simultaneous localization and mapping approach using either local or global approaches. Both approaches suffer from accumulated errors and high processing time due to the iterative nature of the scan matching method. Moreover, point-to-point scan matching is prone to outlier association processes. This paper proposes a low-cost novel method for 2D real-time scan matching based on a reference key frame (RKF). RKF is a hybrid scan matching technique comprised of feature-to-feature and point-to-point approaches. This algorithm aims at mitigating errors accumulation using the key frame technique, which is inspired from video streaming broadcast process. The algorithm depends on the iterative closest point algorithm during the lack of linear features which is typically exhibited in unstructured environments. The algorithm switches back to the RKF once linear features are detected. To validate and evaluate the algorithm, the mapping performance and time consumption are compared with various algorithms in static and dynamic environments. The performance of the algorithm exhibits promising navigational, mapping results and very short computational time, that indicates the potential use of the new algorithm with real-time systems.

  17. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Allisy-Roberts, P. J.; Burns, D. T.; Guerra, A. S.; Laitano, R. F.; Pimpinella, M.

    2010-01-01

    A comparison of the standards for absorbed dose to water of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI), and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation under the auspices of the key comparison BIPM.RI(I)-K4. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the ENEA and the BIPM standards for absorbed dose to water, is 0.9999 (0.0044). The present 2007 result replaces the earlier ENEA value in this key comparison. The degrees of equivalence between the ENEA and the other participants in this comparison have been calculated and the results are given in the form of a matrix for the ten national metrology institutes (NMIs) that have published results in this ongoing comparison for absorbed dose to water. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  18. The Generalized Internal/External Frame of Reference Model: An Extension to Dimensional Comparison Theory

    ERIC Educational Resources Information Center

    Möller, Jens; Müller-Kalthoff, Hanno; Helm, Friederike; Nagy, Nicole; Marsh, Herb W.

    2016-01-01

    The dimensional comparison theory (DCT) focuses on the effects of internal, dimensional comparisons (e.g., "How good am I in math compared to English?") on academic self-concepts with widespread consequences for students' self-evaluation, motivation, and behavioral choices. DCT is based on the internal/external frame of reference model…

  19. Key comparison CCPR-K1.a as an interlaboratory comparison of correlated color temperature

    NASA Astrophysics Data System (ADS)

    Kärhä, P.; Vaskuri, A.; Pulli, T.; Ikonen, E.

    2018-02-01

    We analyze the results of spectral irradiance key comparison CCPR-K1.a for correlated color temperature (CCT). For four participants out of 13, the uncertainties of CCT, calculated using traditional methods, not accounting for correlations, would be too small. The reason for the failure of traditional uncertainty calculation is spectral correlations, producing systematic deviations of the same sign over certain wavelength regions. The results highlight the importance of accounting for such correlations when calculating uncertainties of spectrally integrated quantities.

  20. Synthesized view comparison method for no-reference 3D image quality assessment

    NASA Astrophysics Data System (ADS)

    Luo, Fangzhou; Lin, Chaoyi; Gu, Xiaodong; Ma, Xiaojun

    2018-04-01

    We develop a no-reference image quality assessment metric to evaluate the quality of synthesized view rendered from the Multi-view Video plus Depth (MVD) format. Our metric is named Synthesized View Comparison (SVC), which is designed for real-time quality monitoring at the receiver side in a 3D-TV system. The metric utilizes the virtual views in the middle which are warped from left and right views by Depth-image-based rendering algorithm (DIBR), and compares the difference between the virtual views rendered from different cameras by Structural SIMilarity (SSIM), a popular 2D full-reference image quality assessment metric. The experimental results indicate that our no-reference quality assessment metric for the synthesized images has competitive prediction performance compared with some classic full-reference image quality assessment metrics.

  1. Trial-Type Dependent Frames of Reference for Value Comparison

    PubMed Central

    Hunt, Laurence T.; Woolrich, Mark W.; Rushworth, Matthew F. S.; Behrens, Timothy E. J.

    2013-01-01

    A central question in cognitive neuroscience regards the means by which options are compared and decisions are resolved during value-guided choice. It is clear that several component processes are needed; these include identifying options, a value-based comparison, and implementation of actions to execute the decision. What is less clear is the temporal precedence and functional organisation of these component processes in the brain. Competing models of decision making have proposed that value comparison may occur in the space of alternative actions, or in the space of abstract goods. We hypothesized that the signals observed might in fact depend upon the framing of the decision. We recorded magnetoencephalographic data from humans performing value-guided choices in which two closely related trial types were interleaved. In the first trial type, each option was revealed separately, potentially causing subjects to estimate each action's value as it was revealed and perform comparison in action-space. In the second trial type, both options were presented simultaneously, potentially leading to comparison in abstract goods-space prior to commitment to a specific action. Distinct activity patterns (in distinct brain regions) on the two trial types demonstrated that the observed frame of reference used for decision making indeed differed, despite the information presented being formally identical, between the two trial types. This provides a potential reconciliation of conflicting accounts of value-guided choice. PMID:24068906

  2. Final report on EURAMET.M.P-K4.2010: Key and supplementary comparison of national pressure standards in the range 1 Pa to 15 kPa of absolute and gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajíček, Zdeněk; Bergoglio, Mercede; Jousten, Karl; Otal, Pierre; Sabuga, Wladimir; Saxholm, Sari; Pražák, Dominik; Vičar, Martin

    2014-01-01

    This report describes a EURAMET comparison of five European National Metrology Institutes in low gauge and absolute pressure in gas (nitrogen), denoted as EURAMET.M.P-K4.2010. Its main intention is to state equivalence of the pressure standards, in particular those based on the technology of force-balanced piston gauges such as e.g. FRS by Furness Controls, UK and FPG8601 by DHI-Fluke, USA. It covers the range from 1 Pa to 15 kPa, both gauge and absolute. The comparison in absolute mode serves as a EURAMET Key Comparison which can be linked to CCM.P-K4 and CCM.P-K2 via PTB. The comparison in gauge mode is a supplementary comparison. The comparison was carried out from September 2008 till October 2012. The participating laboratories were the following: CMI, INRIM, LNE, MIKES, PTB-Berlin (absolute pressure 1 kPa and below) and PTB-Braunschweig (absolute pressure 1 kPa and above and gauge pressure). CMI was the pilot laboratory and provided a transfer standard for the comparison. This transfer standard was also the laboratory standard of CMI at the same time, which resulted in a unique and logistically difficult star comparison. Both in gauge and absolute pressures all the participating institutes successfully proved their equivalence with respect to the reference value and all also proved mutual bilateral equivalences in all the points. All the participating laboratories are also equivalent with the reference values of CCM.P-K4 and CCM.P-K2 in the relevant points. The comparison also proved the ability of FPG8601 to serve as a transfer standard. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Subsequent bilateral comparison to CCT-K3, CIPM key comparison CCT-K3.1: Comparison of standard platinum resistance thermometers at the triple point of water (T = 273.16 K) and at the melting point of gallium (T = 302.9146 K)

    NASA Astrophysics Data System (ADS)

    Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.

    2011-01-01

    A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. Final report on COOMET.QM-K76 (COOMET project no 484/RU/09): Key comparison of primary standard gas mixtures: SO2 in nitrogen (100 µmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Shor, N. B.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Kozia, V. G.; Shpilnyi, S. A.; Petryshyn, P. V.; Iakubov, S. E.; Kluchits, A. S.; Ananyin, V. N.; Mironchik, A. M.; Mokhnach, M. V.; Valkova, M.; Stovcik, V.

    2014-01-01

    Sulfur dioxide is one of the main contaminants present in the atmosphere due to burning of coal, oil and natural gas, smelting of base metals and production of sulfuric acid. Sulfur dioxide has been the subject of three previous CCQM key comparisons: CCQM-K1.d in 1997, CCQM-K26.b in 2005 and CCQM-K76 in 2010. VNIIM proposed a new COOMET project (No 484/RU/09) in this field, which was registered in the KCDB as key comparison COOMET.QM-K76. It was found that all results were consistent with the reference (gravimetric) values, with observed differences not exceeding ±0.60% and not exceeding either the appropriate assigned expanded uncertainties. VNIIM is the linking laboratory to CCQM-K76. SMU has improved the results obtained in CCQM-K76. The mixtures prepared for this exercise were found to be stable during about one year within the uncertainty of the measurements. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 1 Ω resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Two BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The mean difference between the NMLI and the BIPM calibrations was found to be just within the expanded uncertainty (k = 2) of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Simple scheme to implement decoy-state reference-frame-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Zhang, Chunmei; Zhu, Jianrong; Wang, Qin

    2018-06-01

    We propose a simple scheme to implement decoy-state reference-frame-independent quantum key distribution (RFI-QKD), where signal states are prepared in Z, X, and Y bases, decoy states are prepared in X and Y bases, and vacuum states are set to no bases. Different from the original decoy-state RFI-QKD scheme whose decoy states are prepared in Z, X and Y bases, in our scheme decoy states are only prepared in X and Y bases, which avoids the redundancy of decoy states in Z basis, saves the random number consumption, simplifies the encoding device of practical RFI-QKD systems, and makes the most of the finite pulses in a short time. Numerical simulations show that, considering the finite size effect with reasonable number of pulses in practical scenarios, our simple decoy-state RFI-QKD scheme exhibits at least comparable or even better performance than that of the original decoy-state RFI-QKD scheme. Especially, in terms of the resistance to the relative rotation of reference frames, our proposed scheme behaves much better than the original scheme, which has great potential to be adopted in current QKD systems.

  7. KEY COMPARISON: Final report on CCQM-K44: Trace elements in sewage sludge

    NASA Astrophysics Data System (ADS)

    Aregbe, Y.; Taylor, P. D. P.

    2009-01-01

    CCQM-K44 was an activity of the Inorganic Analysis Working Group (IAWG) of CCQM and was coordinated by the Joint Research Centre-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) of the European Commission (EC). In CCQM-K44 the amount contents of Cd, Cr, Cu, Pb, Hg, Ni and Zn in sewage sludge were the measurands under investigation. Results were reported by six national metrology institutes (NMIs). During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and agreed on. The final report was submitted in June 2006. After the final report had been submitted to the CCQM in June 2006 the coordinating laboratory was informed that MIRS/IJS was not a designated institute and therefore could not represent the Slovenian NMI in CCQM-K44. This was contrary to what MIRS confirmed to the coordinating laboratory at the beginning of CCQM-K44. After several discussions between MIRS and the CCQM the coordinating laboratory was asked to amend the final report accordingly. In this revised version of the CCQM-K44 final report the results of MIRS/IJS were taken out of CCQM-K44 and included in the pilot study CCQM-P70, which was organised in parallel to CCQM-K44. Due to the limited number of participants compared to previous key comparisons the mixture model median (MM-median) of all reported results could not be applied as KCRV for all the measurands. During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and first agreed on. As a result the final report and degrees of equivalence were finalised and submitted to the CCQM. Subsequent discussions between the IAWG and the CCQM were held, resulting in a different approach as proposed by the coordinating laboratory. Particularly Maurice Cox from NPL recommended the weighted mean and its standard uncertainty (k = 1) as KCRV

  8. Final report on key comparison COOMET.QM-K36 (Project COOMET 540/UA/11) 'Electrolytic Conductivity 0,5 S/m'

    NASA Astrophysics Data System (ADS)

    Gavrilkin, V.; Prokopenko, L.; Bakovec, N.; Zolotorevich, E.; Suvorov, V.; Ovchinnikov, Yu; Pilishvili, T.; Buleishvili, M.; Zhasanbaeva, B.; Aytzhatova, G.; Ticona, G.; Vyskocil, L.

    2015-01-01

    The COOMET.QM-K36 key comparison 'Electrolytic conductivity: 0.5 S/m' is a comparison in the field of electrolytic conductivity measurements conducted by COOMET and carried out in 2012. It used a solution of KCl in water and the results are connected to those of the CCQM key comparison CCQM-K36.a through common participation of VNIIFTRI (Russia), SMU (Slovakia) and Ukrmetrteststandart (Ukraine). The purpose of this key comparison was to establish the equivalence of measurements of electrolytic conductivity performed at the National Metrology Institutes of COOMET member states for the value of 0.5 S/m. The results can be used to support the CMCs claims over the range of 0.1 S/m to 1.3 S/m. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Consensus building for interlaboratory studies, key comparisons, and meta-analysis

    NASA Astrophysics Data System (ADS)

    Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza

    2017-06-01

    Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian

  10. Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 10 kΩ resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NMLI and the BIPM calibrations were found to be in agreement, with a mean difference smaller than the standard uncertainty of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. Final report on APMP.T-K7 key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Tsai, S. F.; White, R.; Tamba, J.; Yamazawa, K.; Ho, M. K.; Tsui, C. M.; Zaid, G.; Achmadi, A.; Gam, K. S.; Othman, H.; Ali, N. M.; Yuan, K. H.; Shaochun, Y.; Liedberg, H.; Yaokulbodee, C.

    2016-01-01

    APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. KEY COMPARISON: Final report on bilateral comparison CCEM.RF-K9.1: Thermal noise standards at 12.4 GHz, 13.5 GHz, 15 GHz and 17.5 GHz

    NASA Astrophysics Data System (ADS)

    Allal, Djamel

    2009-01-01

    A bilateral comparison subsequent to key comparison CCEM.RF-K9 was decided between VNIIFTRI and PTB. It was registered into the BIPM KCDB under the identifier CCEM.RF-K9.1. The results of this comparison were gathered by the pilot laboratory of comparison CCEM.RF-K9, the LNE, and a very good agreement was found between the two participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Rabies vaccine standards: comparison of the 5th and 6th WHO international reference standards to the USDA veterinary reference standard.

    PubMed

    Hermann, J; Fry, A; Reising, M; Patterson, P; Siev, D; Gatewood, D

    2012-11-06

    Ensuring rabies vaccines are potent and effective is paramount in preventing transmission of this deadly disease and safeguarding public health. Efficacy of human and veterinary vaccines is ensured by evaluating relative potency estimates of the vaccine compared to a rabies reference standard using the National Institutes of Health (NIH) test. Reference vaccines are based on the International Standard for Rabies Vaccine provided by the World Health Organization (WHO). A comparison study was conducted to determine the relative potency of the 5th WHO, 6th WHO, and United States Department of Agriculture's (USDA) 08-14 reference standards using the NIH test. Results from the study demonstrate that the 6th WHO reference standard is approximately twice as potent as the 5th WHO reference when reconstituted to contain 1 IU per ml. Based on these results, the Center for Veterinary Biologics (CVB) doubled the reconstitution volume of USDA veterinary reference 08-14 from 13 ml to 26 ml, for an initial use dilution of 0.7 IU per ml for use by veterinary biologics manufacturers in the NIH test. This study emphasizes the importance of reference standard calibration for use in the National Institutes of Health test. Published by Elsevier Ltd.

  14. KEY COMPARISON: CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

    NASA Astrophysics Data System (ADS)

    Seah, M. P.

    2008-01-01

    CCQM-K32 and P84 were conducted following the pilot study P-38 to demonstrate and document the capability of interested National Metrology Institutes to measure the amount of silicon oxide on silicon wafers expressed as a thickness of SiO2 for nominal thicknesses in the range 1.5 nm to 8 nm. 'Amount of substance' may be expressed in many ways and here the measurand is the thickness of the silicon oxide layer on each of a total of 9 samples of nominal thicknesses in the range 1.5 to 8 nm on (100) and (111) Si substrates, expressed as the thickness of SiO2. This report presents the results from K32 and P84. It includes the data received for the measured values and their associated uncertainties, at 95% confidence, for the 9 samples prior to the deadline for receipt of data. The materials are grown by thermal oxidation in very clean furnaces designed for high quality gate oxides on Si wafers in European and US facilities at the same time as those for the pilot study, P-38. Separate samples were provided to each institute in special containers limiting the carbonaceous contamination to below about 0.3 nm. The 9 samples included 5 samples of ultra-thin SiO2 on (100) orientated wafers of Si and 4 samples of ultra-thin SiO2 on (111) orientated wafers of Si. The measurements from the 11 participating laboratories were conducted using ellipsometry, neutron reflectivity (NR), x-ray photoelectron spectroscopy (XPS) or x-ray reflectivity measurements (XRR), guided by the protocol developed in the pilot study P-38 and reproduced in the Appendix. The measurements are given in tables 2 and 3. A very small correction is then made for the different samples that each laboratory received as in table 4. Where appropriate, method offset values deduced from the pilot study P-38 are given in table 5 leading to comparative data in tables 6 and 7. Values for the key comparison reference values (KCRVs) and their associated uncertainties are made from the weighted means and the expanded

  15. Graphical Arrays of Chemical-Specific Health Effect Reference Values for Inhalation Exposures (2009 Final Report)

    EPA Science Inventory

    This document provides graphical arrays and tables of key information on the derivation of human inhalation health effect reference values for specific chemicals, allowing comparisons across durations, populations, and intended use. A number of program offices within the Agency, ...

  16. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Burns, D. T.; Berlyand, V.; Berlyand, A.

    2010-01-01

    A new comparison of the standards for absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation in 2009. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9976 for the calibration coefficients of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. This result is consistent with the earlier 2001 comparison result of 0.9967 (43). The updated degrees of equivalence for the VNIIFTRI are compared with those of the other national metrology institutes as presented in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. International comparison CCQM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Oudwater, Rutger J.; Fioravante, Andreia L.; Augusto, Cristiane R.; Coutinho Brum, Mariana; Uehara, Shinji; Akima, Dai; Bae, Hyun Kil; Kang, Namgoo; Woo, Jin-Chun; Liaskos, Christina E.; Rhoderick, George C.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique; Brewer, Paul J.; Brown, Andrew S.; Bartlett, Sam; Downey, Michael L.; Konopelko, L. A.; Kolobova, A. V.; Pankov, A. A.; Orshanskaya, A. A.; Efremova, O. V.

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare primary standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as a track A key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities using the flexible scheme, and for propane under the default scheme. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results but one are within +/- 0.2 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. KEY COMPARISON: Final report on CCEM key comparison CCEM.RF-K10.CL (GT-RF/99-2) 'Power in 50 Ω coaxial lines, frequency: 50 MHz to 26 GHz' measurement techniques and results

    NASA Astrophysics Data System (ADS)

    Janik, Dieter; Inoue, T.; Michaud, A.

    2006-01-01

    This report summarizes the results and the measuring methods of an international key comparison between twelve national metrology institutes (NMIs) and is concerning the calibration factor of RF power sensors in the coaxial 3.5 mm line for frequencies up to 26 GHz. Two RF power travelling standards fitted with male PC 3.5 mm connectors were measured at seven frequencies. The following NMIs participated: NMIJ (Japan), NRC (Canada), NIST (USA), METAS (Switzerland), CSIR-NML (South Africa), NMIA (Australia), NPL (UK), SiQ (Slovenia), IEN (Italy), VNIIFTRI (Russian Federation), SPRING (Singapore) and PTB (Germany), as the pilot laboratory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Joung, W.; Gam, K. S.; Achmadi, A.; Trisna, B. A.

    2016-01-01

    The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. International comparison Euramet.QM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    Wouter van der Hout, J.; van der Veen, Adriaan M. H.; Ziel, Paul R.; Kipphardt, Heinrich; Tuma, Dirk; Maiwald, Michael; Fernández, Teresa E.; Gómez, Concepción; Cieciora, Dariusz; Ochman, Grzegorz; Dias, Florbela; Silvino, Victor; Macé, Tatiana; Sutour, Christophe; Marioni, Fabrice; Ackermann, Andreas; Niederhauser, Bernhard; Fükő, Judit; Büki, Tamás; Nagyné Szilágyi, Zsófia; Tarhan, Tanıl; Engin, Erinç

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within +/- 1 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. KEY COMPARISON: Final report of the CCQM-K56: Ca, Fe, Zn and Cu in whole fat soybean powder

    NASA Astrophysics Data System (ADS)

    Liandi, Ma; Qian, Wang

    2010-01-01

    The CCQM-K56 key comparison was organized by the Inorganic Analysis Working Group (IAWG) of CCQM as a follow-up to completed pilot study CCQM-P64 to test the abilities of national metrology institutes to measure the amount content of nutritious elements in whole fat soybean powder. A pilot study CCQM-P64.1 was conducted in parallel with this key comparison. The National Institute of Metrology (NIM), P. R. China, acted as the coordinating laboratory. Eleven NIMs participated in CCQM-K56. Four elements - Ca, Fe, Zn and Cu - in different concentration levels have been studied. Different measurement methods (IDMS, ICP-MS, ICP-OES, AAS and INAA) and the microwave digestion method were used. The agreement of the results of CCQM-K56 is very good, and obviously better than that of the original P64. It shows that the capability of all of the participants had been promoted from the original pilot study to this key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Power, Oliver

    2017-01-01

    This report presents the results of a bilateral comparison of capacitance at 100 pF between the NSAI-NML (Ireland) and the BIPM carried out in 2016. This comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b in which the BIPM is the pilot laboratory. Two 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring rms voltage of 15 V. The results from the NSAI-NML and the BIPM were found to be in relatively good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.85 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. KEY COMPARISON: Final report on CCQM-K57: Chemical composition of clay

    NASA Astrophysics Data System (ADS)

    Salas, Antonio; Ramírez, Estele

    2009-01-01

    After the successful completion of the pilot study, CCQM-P65 [1], the Inorganic Analysis Working Group of CCQM agreed to conduct key comparison CCQM-K57, Chemical composition of clay, in Paris, April 2006. The natural mass fraction levels of five elements—Si, Ca, Fe, Al and Mg—were measured and reported as oxides in clay. Six national metrology institutes participated in CCQM K57, and CENAM (Querétaro, Mexico) coordinated. The methods employed were isotope dilution mass spectrometry (IDMS), inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-optical emission spectrometry (ICP-OES) using the dehydration method and condensation method, gravimetric analysis, neutron activation analysis (NAA), prompt gamma activation analysis (PGAA) and x-ray fluorescence spectrometry (XRF) with the reconstitution method and external calibration. This final report presents the capability of the participant institutes, based on the KCRV, which was approved at the IAWG spring meeting in 2008, and the equivalence statements regarding the KCRV, approved at its autumn meeting. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. KEY COMPARISON: Final report on Key Comparison APMP.SIM.M.P-K1c: Bilateral comparison between NIST (USA) and NPLI (India) in the pneumatic pressure region 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Driver, R. Gregory; Olson, Douglas A.; Dilawar, Nita; Bandyopadhyay, A. K.

    2007-01-01

    We report the results of a bilateral comparison of pressure measurement between NIST and NPLI using a piston gauge transfer standard (TS), designated as NPLI-4, over the range of nominal applied pressure 0.4 MPa to 4.0 MPa. This TS was cross-floated against the laboratory secondary standard designated as PG13 at NIST, USA and against NPLI-8 at NPLI, India. The nominal pressure points of the bilateral comparison were (0.4, 0.8, 1.2, 1.6, 2.0, 2.4, 2.8, 3.2, 3.6 and 4.0) MPa, respectively. The comparison was performed in both the institutes in identical pressure cycles in increasing pressures. The comparison data were analysed in terms of the effective area [Ap (mm2)] as a function pressure [p (MPa)] of the TS at the above-mentioned pressures. We have also estimated the zero-pressure effective area [A0 (mm2)] and the pressure distortion coefficient [λ (MPa-1)] of the transfer standard. The consistency of the results at every pressure in the range indicates that the laboratory standards used in this comparison are compatible, uniform and can be considered traceable to each other. Finally, the degree of equivalence between NPLI and NIST is 11.4 × 10-6 or better, which is always less than the relative standard uncertainty of the difference (33.6 × 10-6). Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Final report of CCAUV.V-K3: key comparison in the field of acceleration on the complex charge sensitivity

    NASA Astrophysics Data System (ADS)

    Qiao, Sun; Lifeng, Yang; Bartoli, Claire; Veldman, Ian; Ripper, Gustavo P.; Bruns, Thomas; Rask Licht, Torben; Kolasa, Joanna; Hof, Christian; Silva Pineda, Guillermo; Dickinson, Laurence; Ota, Akihiro; Cheung, Wan Sup; Yankovsky, Alexander; Shan, Cui

    2017-01-01

    This is the final report for CIPM key comparison CCAUV.V-K3 in the area of 'vibration' (quantity of acceleration). The aim of this comparison was to measure the voltage sensitivity of one accelerometer standard set with primary means at 27 frequencies from 0.1 Hz to 40 Hz. Fourteen Metrology Institutes from five RMOs have participated in the comparison with National Institute of Metrology, P.R. China as pilot lab and Laboratoire National de Métrologie et d'Essais and National Metrology Institute of South Africa as co-pilot labs. One quartz-flexure servo accelerometer of single-ended type and a signal conditioner was circulated among the participants. All but one of the participating laboratories provided their calibration results, which were mostly consistent within their declared expanded uncertainties for magnitude results. Only two participants failed to contribute to the KCRV values calculated for five frequencies. For phase shift, three participants could not contribute to the calculation of the KCRV values in a total of sixteen frequencies. This first low-frequency vibration key comparison revealed the current calibration capabilities of the fourteen participants of five RMOs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Comparison of tiered formularies and reference pricing policies: a systematic review

    PubMed Central

    Morgan, Steve; Hanley, Gillian; Greyson, Devon

    2009-01-01

    Objectives To synthesize methodologically comparable evidence from the published literature regarding the outcomes of tiered formularies and therapeutic reference pricing of prescription drugs. Methods We searched the following electronic databases: ABI/Inform, CINAHL, Clinical Evidence, Digital Dissertations & Theses, Evidence-Based Medicine Reviews (which incorporates ACP Journal Club, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Cochrane Methodology Register, Database of Abstracts of Reviews of Effectiveness, Health Technology Assessments and NHS Economic Evaluation Database), EconLit, EMBASE, International Pharmaceutical Abstracts, MEDLINE, PAIS International and PAIS Archive, and the Web of Science. We also searched the reference lists of relevant articles and several grey literature sources. We sought English-language studies published from 1986 to 2007 that examined the effects of either therapeutic reference pricing or tiered formularies, reported on outcomes relevant to patient care and cost-effectiveness, and employed quantitative study designs that included concurrent or historical comparison groups. We abstracted and assessed potentially appropriate articles using a modified version of the data abstraction form developed by the Cochrane Effective Practice and Organisation of Care Group. Results From an initial list of 2964 citations, 12 citations (representing 11 studies) were deemed eligible for inclusion in our review: 3 studies (reported in 4 articles) of reference pricing and 8 studies of tiered formularies. The introduction of reference pricing was associated with reduced plan spending, switching to preferred medicines, reduced overall drug utilization and short-term increases in the use of physician services. Reference pricing was not associated with adverse health impacts. The introduction of tiered formularies was associated with reduced plan expenditures, greater patient costs and increased rates of

  7. SUPPLEMENTARY COMPARISON: Final report on APMP.PR-S1.1: Bilateral comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Huang, Xuebo

    2009-01-01

    In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Activity measurements of a suite of radionuclides (241Am, 239,240Pu, 238Pu, 238U, 234U, 235U, 232Th, 230Th, 228Th, 228Ra, 137Cs, 210Pb, 90Sr and 40K) in biota reference material (Ocean Shellfish): CCRI(II)-S3

    NASA Astrophysics Data System (ADS)

    Nour, S.; Karam, L. R.; Inn, K. G. W.

    2012-01-01

    In 2005, the CCRI decided that a comparison undertaken from 2002 to 2008 by the NIST (under the auspices of the Inter-America Metrology System [SIM]) in the development of a new biota (Ocean Shellfish) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S3. This would enable the comparison to be used to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference materials (specifically, animal-based organic materials). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (shellfish) so as to support CMCs of similar materials submitted by the present participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. SUPPLEMENTARY COMPARISON: APMP.PR-S1 comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Xu, Gan; Huang, Xuebo; Liu, Yuanjie

    2007-01-01

    APMP.PR-S1, a supplementary comparison of irradiance responsivity of UVA detectors, was carried out among seven national metrology institutes piloted by SPRING Singapore from 2003 to 2005. Two quantities, the narrow band UV (365 nm ± 5 nm) irradiance responsivity and the broad band UVA (315 nm-400 nm) irradiance responsivity of the transfer detectors, have been compared. Commercial UV source (medium pressure mercury short arc lamp) and UVA detectors were used as transfer standards in the comparison. Measurement results from participants were reported and their uncertainties associated with the comparison were analysed in this report. The method of weighted mean with cut-off was used to calculate the comparison reference values. The results from most participating labs lie within ±5% against the comparison reference values with a few exceptions. The degree of agreement of the comparison depends not only on the base scales of spectral responsivity and spectral irradiance of a laboratory, but also equally importantly on the method used for the measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. KEY COMPARISON: Final report of EUROMET Project 696: pH determination of a phthalate buffer

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Charlet, Philippe; Eberhard, Ralf; Karpov, Oleg V.; Philippe, Rachel; Rivier, Cedric; Maximov, Igor; Sudmeier, Uwe

    2005-01-01

    The EUROMET project 696, a trilateral comparison between PTB, Germany, LNE, France and VNIIFTRI, Russia was performed in order to demonstrate and document the capability of the participants to measure the pH of a phthalate buffer by the primary measurement procedure for pH. Good agreement of the reported results was observed. The sample was very similar to the one used in the comparison CCQM-K17. PTB acts as pilot laboratory in CCQM-K17 and in EUROMET 696. This comparison allows one to link the results obtained by LNE to the CCQM-K17 key comparison through the degree of equivalence of PTB. On the other hand, the discrepancy between measured pH values at the VNIIFTRI and PTB for the same type of buffer solution decreased, as compared with a bilateral comparison in 1997. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  11. USE OF FAST GC/TOFMS AS REFERENCE STANDARD FOR FIELD COMPARISON STUDIES WITH ON-SITE INSTRUMENTS

    EPA Science Inventory

    A faster reference standard for field comparison studies of portable gas chromatographs (PGC) is needed. A performance evaluation of a high-speed GCMS (FGC/MS) system conducted during 1998 demonstrated generally satisfactory performance, but it was evident that performance of b...

  12. KEY COMPARISON Comparison of the standards of air kerma of the ENEA-INMRI and the BIPM for 137Cs gamma rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Toni, M.; Bovi, M.

    2010-01-01

    A comparison of the standards of air kerma of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI) and of the Bureau International des Poids et Mesures (BIPM) was carried out in 137Cs radiation in 1998. The comparison result, updated for changes in the standards in 2003 and 2009, is 0.9927 (0.0067) and demonstrates that the ENEA-INMRI and BIPM standards are in agreement within the uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Key comparison SIM.EM.RF-K5b.CL: scattering coefficients by broad-band methods, 2 GHz-18 GHz — type N connector

    NASA Astrophysics Data System (ADS)

    Silva, H.; Monasterios, G.

    2016-01-01

    The first key comparison in microwave frequencies within the SIM (Sistema Interamericano de Metrología) region has been carried out. The measurands were the S-parameters of 50 ohm coaxial devices with Type-N connectors and were measured at 2 GHz, 9 GHz and 18 GHz. SIM.EM.RF-K5b.CL was the identification assigned and it was based on a parent CCEM key comparison named CCEM.RF-K5b.CL. For this reason, the measurements standards and their nominal values were selected accordingly, i.e. two one-port devices (a matched and a mismatched load) to cover low and high reflection coefficients and two attenuators (3dB and 20 dB) to cover low and high transmission coefficients. This key comparison has met the need for ensuring traceability in high-frequency measurements across America by linking SIM's results to CCEM. Six NMIs have participated in this comparison which was piloted by the Instituto Nacional de Tecnología Industrial (Argentina). A linking method of multivariate values was proposed and implemented in order to allow the linking of 2-dimensional results. KEY WORDS FOR SEARCH Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Interlaboratory comparison program for nondestructive assay of prototype uranium reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trahey, N.M.; Smith, M.M.; Voeks, A.M.

    The US Department of Energy (DOE), New Brunswick Laboratory (NBS), designed and administered an interlaboratory comparison program based on the measurement of NBL-produced prototype uranium nondestructive assay (NDA) reference materials for scrap and waste. The objectives of the program were to evaluate the reliability of NDA techniques as applied to nuclear safeguards materials control and accountability needs and to investigate the feasibility of providing practical NDA scrap and waste reference materials for use throughout the nuclear safeguards community. Fourteen facilities representing seven DOE contractors, four US Nuclear Regulatory Commission (NRC) licensees, one EURATOM Laboratory, and NBL, participated in this program.more » Three stable, well-characterized uranium reference materials were developed and certified for this program. Synthetic calcined ash, cellulose fiber, and ion-exchange resin simulate selected uranium scrap and waste forms which are often encountered in fabrication and recovery operations. The synthetic calcined ash represents an intermediate density inorganic matrix while the cellulose fiber and ion-exchange resin are representative of low-density organic matrices. The materials, containing from 0 to 13% uranium enriched at 93% /sup 235/U, were sealed in specially selected containers. Nineteen prototype reference samples, plus three empty containers, one to accompany each set, was circulated to the participants between August 1979 and May 1984. Triplicate measurements for /sup 235/U on each of the 19 filled containers were required. In addition, participants could opt to perform modular configuration measurements using containers from Sets IIA and IIB to simulate non-homogeneously dispersed uranium in waste containers. All data were reported to NBL for evaluation.« less

  15. KEY COMPARISON: CCEM.RF-K9: International comparison of thermal noise standards between 12.4 GHz and 18 GHz (GT-RF/99-1)

    NASA Astrophysics Data System (ADS)

    Allal, Djamel; Achkar, Joseph

    2006-01-01

    An international comparison of thermal noise-power measurements has been carried out among five national metrology institutes between 12.4 GHz and 18 GHz. Four transfer standards were measured. The following national institutes participated: BNM-LCIE (France), NPL (United Kingdom), PTB (Germany), NIST (United States of America) and VNIIFTRI (Russia). The Bureau National de Métrologie-Laboratoire Central des Industries Electriques (France) acted as the pilot laboratory for the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays.

    PubMed

    Burns, D T; Kessler, C; O'Brien, M; Minniti, R

    2012-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x-ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 10 3 , except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database.

  17. Sensor Level Functional Connectivity Topography Comparison Between Different References Based EEG and MEG.

    PubMed

    Huang, Yunzhi; Zhang, Junpeng; Cui, Yuan; Yang, Gang; Liu, Qi; Yin, Guangfu

    2018-01-01

    Sensor-level functional connectivity topography (sFCT) contributes significantly to our understanding of brain networks. sFCT can be constructed using either electroencephalography (EEG) or magnetoencephalography (MEG). Here, we compared sFCT within the EEG modality and between EEG and MEG modalities. We first used simulations to look at how different EEG references-including the Reference Electrode Standardization Technique (REST), average reference (AR), linked mastoids (LM), and left mastoid references (LR)-affect EEG-based sFCT. The results showed that REST decreased the reference effects on scalp EEG recordings, making REST-based sFCT closer to the ground truth (sFCT based on ideal recordings). For the inter-modality simulation comparisons, we compared each type of EEG-sFCT with MEG-sFCT using three metrics to quantize the differences: Relative Error (RE), Overlap Rate (OR), and Hamming Distance (HD). When two sFCTs are similar, RE and HD are low, while OR is high. Results showed that among all reference schemes, EEG-and MEG-sFCT were most similar when the EEG was REST-based and the EEG and MEG were recorded simultaneously. Next, we analyzed simultaneously recorded MEG and EEG data from publicly available face-recognition experiments using a similar procedure as in the simulations. The results showed (1) if MEG-sFCT is the standard, REST-and LM-based sFCT provided results closer to this standard in the terms of HD; (2) REST-based sFCT and MEG-sFCT had the highest similarity in terms of RE; (3) REST-based sFCT had the most overlapping edges with MEG-sFCT in terms of OR. This study thus provides new insights into the effect of different reference schemes on sFCT and the similarity between MEG and EEG in terms of sFCT.

  18. Key comparison BIPM.RI(I)-K9 of the absorbed dose to water standards of the PTB, Germany and the BIPM in medium-energy x-rays

    NASA Astrophysics Data System (ADS)

    Burns, D. T.; Kessler, C.; Büermann, L.; Ketelhut, S.

    2018-01-01

    A key comparison has been made between the absorbed dose to water standards of the PTB, Germany and the BIPM in the medium-energy x-ray range. The results show the standards to be in general agreement at the level of the standard uncertainty of the comparison of 9 to 11 parts in 103. The results are combined with those of a EURAMET comparison and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the SMU, Slovakia and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    A key comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0042 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIST, USA and the BIPM in medium-energy x-rays

    PubMed Central

    Burns, D T; Kessler, C; O’Brien, M; Minniti, R

    2017-01-01

    A key comparison has been made between the air-kerma standards of the NIST, USA and the BIPM in the medium-energy x–ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.8 parts in 103, except at 250 kV where the difference is 1.5 times the standard uncertainty. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. PMID:28966399

  1. High key rate continuous-variable quantum key distribution with a real local oscillator.

    PubMed

    Wang, Tao; Huang, Peng; Zhou, Yingming; Liu, Weiqi; Ma, Hongxin; Wang, Shiyu; Zeng, Guihua

    2018-02-05

    Continuous-variable quantum key distribution (CVQKD) with a real local oscillator (LO) has been extensively studied recently due to its security and simplicity. In this paper, we propose a novel implementation of a high-key-rate CVQKD with a real LO. Particularly, with the help of the simultaneously generated reference pulse, the phase drift of the signal is tracked in real time and then compensated. By utilizing the time and polarization multiplexing techniques to isolate the reference pulse and controlling the intensity of it, not only the contamination from it is suppressed, but also a high accuracy of the phase compensation can be guaranteed. Besides, we employ homodyne detection on the signal to ensure the high quantum efficiency and heterodyne detection on the reference pulse to acquire the complete phase information of it. In order to suppress the excess noise, a theoretical noise model for our scheme is established. According to this model, the impact of the modulation variance and the intensity of the reference pulse are both analysed theoretically and then optimized according to the experimental data. By measuring the excess noise in the 25km optical fiber transmission system, a 3.14Mbps key rate in the asymptotic regime proves to be achievable. This work verifies the feasibility of the high-key-rate CVQKD with a real LO within the metropolitan area.

  2. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NIS (Egypt) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Helmy, M.; Raouf, A.; Hamed, Heba A. M.; Eliwa Gad, A.

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NIS (Egypt) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NIS, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NIS and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of about 0.72 × 10-6 at 10 pF and about 0.65 × 10-6 at 100 pF. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Dental age assessment of Maltese children and adolescents. Development of a reference dataset and comparison with a United Kingdom Caucasian reference dataset.

    PubMed

    Elshehawi, Waleed; Alsaffar, Hani; Roberts, Graham; Lucas, Victoria; McDonald, Fraser; Camilleri, Simon

    2016-04-01

    The purpose of this study was to develop and validate a Reference Data Set for Dental Age Assessment of the Maltese population and compare the mean Age of Attainment to a UK Caucasian Reference Data Set. The Maltese Reference Data Set was developed from 1593 Dental Panoramic Tomograms of patients aged between 4 and 26 years, taken from the radiographic archives of the Dental Department, Mater Dei Hospital, Malta. Tooth Development Stages were recorded for all 16 maxillary and mandibular permanent teeth on the left side and both permanent third molars on the right, according to Demirjian's staging method. Summary and percentile data were calculated for each Tooth Development Stage, including the mean Age of Attainment. These means were used to estimate the Dental Age of each subject in the study sample using the simple unweighted average method. The estimated Dental Age was compared to the gold standard of the Chronological Age. Comparison of the Maltese and UK Caucasian Reference Data Set was by a series of t-tests, carried out for each paired Tooth Development Stage by gender. The mean Age of Attainment was slightly higher for the Maltese than the UK Caucasians in both males and females. However there was no statistically significant difference between the Chronological Age and Dental Age for either sex. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  4. Report of the key comparison CCQM-K108 determination of arsenic species, total arsenic and cadmium in brown rice flour

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shinichi; Kotzeva, Boriana; Kakoulides, Elias; Sxoina, Vasiliki; Fung, W. H.; Choi, Y. Y.; Yau, H. P.; Tsoi, Y. T.; Lee, C. L.; Kong, M. F.; Shin, Richard; Juan, Wang; Sin Yee, Ng; Uribe, Christian; Marques Rodrigues, Janaína; Caciano de Sena, Rodrigo; Silva Dutra, Emily; Bergamaschi, Luigi; Giordani, Laura; D'Agostino, Giancarlo; Valiente, Liliana; Horvat, Milena; Jacimovic, Radojko; Oduor Okumu, Tom; Kang'Iri, Jacqueline; Owiti Orwa, Tabitha; Chao, Wei; Jingbo, Chao; Taebunpakul, Sutthinun; Yafa, Charun; Kaewkhomdee, Nattikarn; Chailap, Benjamat; Pharat, Yanee; Phukphattanachai, Pranee; Turk, Gregory C.; Long, Stephen; Murphy, K. E.; Davis, Clay; Ellisor, Michael; Merrick, Jeffrey; White, Ian; Saxby, David; Linsky, S. M.; Barzev, A.; Botha, A.

    2015-01-01

    The CCQM-K108 key comparison was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes (NMIs) or designated institutes (DIs) to measure the mass fractions of arsenic species, total arsenic and cadmium in brown rice flour. The National Metrology Institute of Japan (NMIJ) acted as the coordinating laboratory. The participants used different measurement methods, though most of them used inductively coupled plasma mass spectrometry (ICP-MS) or isotope-dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) for Cd and ICP-MS for total arsenic. Regarding arsenic speciation, all participants used ICP-MS coupled with liquid chromatography (LC). Accounting for relative expanded uncertainty, comparability of measurement results for each of total arsenic and cadmium was successfully demonstrated by the participating NMIs or DIs for the measurement of the measurand at the level of less than 0.5 mg/kg. Regarding arsenic species (inorganic arsenic and dimethylarsinic acid (DMAA)), there was, however, a measurement problem still to be solved and that part of CCQM-K108 will be repeated. It is expected that arsenic, cadmium and other metals at mass fractions greater than approximately 0.1 mg/kg in rice flour can be determined by each participant using the same technique(s) employed for this key comparison to achieve similar uncertainties mentioned in the present report. Furthermore, the results of this key comparison can be utilised along with the IAWG core capability approach. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Sensor Level Functional Connectivity Topography Comparison Between Different References Based EEG and MEG

    PubMed Central

    Huang, Yunzhi; Zhang, Junpeng; Cui, Yuan; Yang, Gang; Liu, Qi; Yin, Guangfu

    2018-01-01

    Sensor-level functional connectivity topography (sFCT) contributes significantly to our understanding of brain networks. sFCT can be constructed using either electroencephalography (EEG) or magnetoencephalography (MEG). Here, we compared sFCT within the EEG modality and between EEG and MEG modalities. We first used simulations to look at how different EEG references—including the Reference Electrode Standardization Technique (REST), average reference (AR), linked mastoids (LM), and left mastoid references (LR)—affect EEG-based sFCT. The results showed that REST decreased the reference effects on scalp EEG recordings, making REST-based sFCT closer to the ground truth (sFCT based on ideal recordings). For the inter-modality simulation comparisons, we compared each type of EEG-sFCT with MEG-sFCT using three metrics to quantize the differences: Relative Error (RE), Overlap Rate (OR), and Hamming Distance (HD). When two sFCTs are similar, RE and HD are low, while OR is high. Results showed that among all reference schemes, EEG-and MEG-sFCT were most similar when the EEG was REST-based and the EEG and MEG were recorded simultaneously. Next, we analyzed simultaneously recorded MEG and EEG data from publicly available face-recognition experiments using a similar procedure as in the simulations. The results showed (1) if MEG-sFCT is the standard, REST—and LM-based sFCT provided results closer to this standard in the terms of HD; (2) REST-based sFCT and MEG-sFCT had the highest similarity in terms of RE; (3) REST-based sFCT had the most overlapping edges with MEG-sFCT in terms of OR. This study thus provides new insights into the effect of different reference schemes on sFCT and the similarity between MEG and EEG in terms of sFCT. PMID:29867395

  6. Final report on APMP.T-K7.1 key comparison of water triple point cells, bilateral NMIJ-VMI

    NASA Astrophysics Data System (ADS)

    Yamazawa, Kazuaki; Nakano, Tohru; Thanh Binh, Pham

    2018-01-01

    APMP.T-K7.1, was held from July 2014 to May 2015 to compare the national realizations of the water triple point between NMIJ (Japan) and VMI (Vietnam). To reach the objective, VMI sent a transfer cell to NMIJ and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the NMIJ and at the VMI, and aims to link the results of APMP.T-K7.1 to APMP.T-K7 and CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.66 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A—B—A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 2.5 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Secure polarization-independent subcarrier quantum key distribution in optical fiber channel using BB84 protocol with a strong reference.

    PubMed

    Gleim, A V; Egorov, V I; Nazarov, Yu V; Smirnov, S V; Chistyakov, V V; Bannik, O I; Anisimov, A A; Kynev, S M; Ivanova, A E; Collins, R J; Kozlov, S A; Buller, G S

    2016-02-08

    A quantum key distribution system based on the subcarrier wave modulation method has been demonstrated which employs the BB84 protocol with a strong reference to generate secure bits at a rate of 16.5 kbit/s with an error of 0.5% over an optical channel of 10 dB loss, and 18 bits/s with an error of 0.75% over 25 dB of channel loss. To the best of our knowledge, these results represent the highest channel loss reported for secure quantum key distribution using the subcarrier wave approach. A passive unidirectional scheme has been used to compensate for the polarization dependence of the phase modulators in the receiver module, which resulted in a high visibility of 98.8%. The system is thus fully insensitive to polarization fluctuations and robust to environmental changes, making the approach promising for use in optical telecommunication networks. Further improvements in secure key rate and transmission distance can be achieved by implementing the decoy states protocol or by optimizing the mean photon number used in line with experimental parameters.

  12. Reference standards, judges, and comparison subjects: roles for experts in evaluating system performance.

    PubMed

    Hripcsak, George; Wilcox, Adam

    2002-01-01

    Medical informatics systems are often designed to perform at the level of human experts. Evaluation of the performance of these systems is often constrained by lack of reference standards, either because the appropriate response is not known or because no simple appropriate response exists. Even when performance can be assessed, it is not always clear whether the performance is sufficient or reasonable. These challenges can be addressed if an evaluator enlists the help of clinical domain experts. 1) The experts can carry out the same tasks as the system, and then their responses can be combined to generate a reference standard. 2)The experts can judge the appropriateness of system output directly. 3) The experts can serve as comparison subjects with which the system can be compared. These are separate roles that have different implications for study design, metrics, and issues of reliability and validity. Diagrams help delineate the roles of experts in complex study designs.

  13. [Validation of BREV: comparison with reference battery in 173 children with learning disorders].

    PubMed

    Billard, C; Ducot, B; Pinton, F; Coste-Zeitoun, D; Picard, S; Warszawski, J

    2006-01-01

    The BREV battery (Battery for rapid evaluation of cognitive functions) is a tool which can be used for the rapid neuropsychological evaluation of children aged between 4 and 9 years. After standardization (700 unaffected children) and validation by comparison with a reference battery (202 children with epilepsy), the aim of this study was further validation in 173 children with learning disorders. The study protocol included administration of the BREV, precise neuropsychological examination and evaluation of oral and written language. Statistical analysis was used to compare the findings of the BREV with those of the reference method, and the recommendations indicated by the BREV with the final diagnoses, and to define the sensitivity and the specificity of the BREV battery. All the correlations between BREV tests and reference tests were significant. Recommendations after the BREV were in agreement with the conclusions of the reference evaluation in 168/172 children for language, 145/173 for the psychometric evaluation. For only 4 chidren, the results of the BREV were false negative. Diagnoses corresponded in 168/173 children for oral language, in 102/110 for written language, 166/173 for praxis disorders and 157/173 for intellectual deficit. The most predictive subtests of the BREV and sensitivity and specificity of verbal and non-verbal scores were calculated. The BREV is a reliable examination, in learning disorders, to determine the most complementary investigations both in terms of language disorders and for non-verbal or global learning disabilities.

  14. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NMISA (South Africa) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Khoza, Michael

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NMISA (South Africa) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NMISA, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NMISA and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of maximum value 0.33 × 10-6 at 10 pF and 0.24 × 10-6 at 100 pF (and 1000 Hz in both cases). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. COMPARISON OF PULMONARY RESPONSES TO AUTOMOBILE-GENERATED AND NIST STANDARD REFERENCE MATERIAL DIESEL PARTICULATE EMISSIONS IN MICE

    EPA Science Inventory

    COMPARISON OF PULMONARY RESPONSES TO AUTOMOBILE-GENERATED AND NIST STANDARD REFERENCE MATERIAL DIESEL PARTICULATE EMISSIONS IN MICE. P. Singh1, C.A.J. Dick2, J. Richards3, M.J. Daniels3, and M.I. Gilmour3. 1NCSU, Raleigh, NC, 2UNC, Chapel Hill, NC and 3 USEPA, ORD, NHEERL, (ETD,...

  16. International comparison of AC-DC current transfer standards

    NASA Astrophysics Data System (ADS)

    Heine, G.; Garcocz, M.; Waldmann, W.

    2017-01-01

    The measurements of the international comparison of ac-dc current transfer standards identified as EURAMET.EM-K12 started in June 2012 and were completed in December 2014. Twenty NMIs in the EURAMET region and one NMI in the AFRIMET region took part: BEV (Austria), CMI (Czech Republic), PTB (Germany), METAS (Switzerland), JV (Norway), UME (Turkey), GUM (Poland), IPQ (Portugal), CEM (Spain), INRIM (Italy), SP (Sweden), DANIAmet-MI-Trescal (Denmark), BIM (Bulgaria), MKEH (Hungary), SIQ (Slovenia), LNE (France), NSAI NML (Ireland), VSL (The Netherlands), NPL (United Kingdom), Metrosert (Estonia), NIS (Egypt). The comparison was proposed to link the National Metrology Institutes organised in EURAMET to the key comparison CCEM-K12. The ac-dc current transfer difference of each travelling standard had been measured at its nominal current 10 mA and 5 A at the following frequencies: 10 Hz, 55 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz. The test points were selected to link the results with the equivalent CCEM Key Comparison (CCEM-K12), through five NMIs participating in both EURAMET and CCEM key comparisons (PTB, JV, NPL, SP and BEV). The report shows the degree of equivalence in the EURAMET region and also the degree of equivalence with the corresponding CCEM reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Quantum key distribution with finite resources: Secret key rates via Renyi entropies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abruzzo, Silvestre; Kampermann, Hermann; Mertz, Markus

    A realistic quantum key distribution (QKD) protocol necessarily deals with finite resources, such as the number of signals exchanged by the two parties. We derive a bound on the secret key rate which is expressed as an optimization problem over Renyi entropies. Under the assumption of collective attacks by an eavesdropper, a computable estimate of our bound for the six-state protocol is provided. This bound leads to improved key rates in comparison to previous results.

  18. KEY COMPARISON: Final report on CCQM-K63.a,b: Non-peptide hormones in serum: cortisol and progesterone

    NASA Astrophysics Data System (ADS)

    S-C Tai, Susan; Duewer, David L.

    2010-01-01

    Hormones are chemical messengers that regulate many life functions. Deviations from normal hormone levels can have serious health consequences. Accurate measurement of hormone levels in serum can be beneficial in diagnosing, monitoring, and treating a number of diseases. Two steroid hormones, cortisol and progesterone, were selected by the Organic Analysis Working Group (OAWG) to evaluate its member Institutes' measurement capabilities for this important class of measurand. Serum concentrations of cortisol range from 30 ng/mL to 230 ng/mL. Serum concentrations of progesterone in adult females range from 0.15 ng/mL to 25 ng/mL but can rise to approx230 ng/mL during pregnancy. The ability to measure cortisol is indicative of a laboratory's ability to measure steroid hormones at concentration levels similar to cortisol. The ability to measure progesterone is indicative of a laboratory's ability to measure steroid hormones with similar functional groups and concentration levels, such as testosterone. Pilot studies CCQM-P77.a and CCQM-P77.b on the determination of cortisol and progesterone in human serum were completed in 2006. There was good agreement among the results reported by participants who used isotope dilution/mass spectrometry (ID/MS) with either gas chromatography (GC) or liquid chromatography (LC). In 2007 the OAWG decided to proceed with key comparison (KC) CCQM-K63.a, cortisol in human serum, and CCQM-K63.b, progesterone in human serum. Thus, following established OAWG procedure, only results from participants that (1) used an ID/MS-based method, (2) participated in the relevant pilot study, and (3) used a metrologically traceable primary standard were to be eligible for use in calculating the key comparison reference value (KCRV) for each measurand. Six laboratories participated in CCQM-K63.a and eight laboratories participated in CCQM-K63.b. The same pooled frozen female serum material was used in both of the KCs. The mean value for the six ID

  19. Aggression in children with autism spectrum disorders and a clinic-referred comparison group

    PubMed Central

    Farmer, Cristan; Butter, Eric; Mazurek, Micah O.; Cowan, Charles; Lainhart, Janet; Cook, Edwin H.; DeWitt, Mary Beth; Aman, Michael

    2015-01-01

    A gap exists in the literature regarding aggression in autism spectrum disorders (ASD) and how this behavior compares to other groups. In this multisite study, the Children’s Scale for Hostility and Aggression: Reactive/Proactive (C-SHARP) and the Aggression subscale of the Child Behavior Checklist (CBCL) were rated for 414 children with ASD (Autistic Disorder, 69%; PDD-NOS, 24%; Asperger’s Disorder, 7%) and 243 clinic-referred children without ASD, aged 1-21 years (mean age about 7). Participants were not selected for aggressive behavior. Relative to the comparison group, children with ASD were reported to have less aggression and were more likely to be rated as reactive rather than proactive. Among all subjects, sex was not associated with aggression; higher IQ/adaptive behavior and older age were associated with more sophisticated types of aggression while lower scores on IQ, adaptive behavior, and communication measures were associated with more physical aggression. The interaction between demographic variables and diagnosis was significant only for age: younger but not older children with ASD showed less aggression than clinic-referred controls. PMID:24497627

  20. KEY COMPARISON: CCQM-K28: Tributyltin in sediment

    NASA Astrophysics Data System (ADS)

    Wolff Briche, Céline S. J.; Wahlen, Raimund; Sturgeon, Ralph E.

    2006-01-01

    Key comparison CCQM K-28 was undertaken to assess the measurement capabilities for quantitation of (C4H9)3Sn+ (TBT) in a prepared marine sediment by National Metrology Institutes (NMIs), which are members of the Comité Consultatif pour la Quantité de Matière (CCQM). It follows a previous pilot study, CCQM-P18. [1, 2] This exercise was sanctioned by the 8th CCQM meeting, 18-19 April 2002, as an activity of the Inorganic Analysis Working Group and was jointly coordinated by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and LGC, UK. Eight NMIs initially indicated their interest, with seven ultimately submitting their results. All NMIs relied on isotope dilution mass spectrometry using a species-specific 117Sn-enriched TBT standard, which was supplied by LGC. No analytical methodology was prescribed for this study. As a result, a variety of extraction approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with ethylation and direct sampling. Detection techniques included ICP-MS (coupled to GC or HPLC for the separation of Sn species) and GC-MS. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  1. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the SMD (Belgium) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, Benjamin; Fletcher, Nick; Vlad, Dana

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the SMD (Belgium) and the BIPM carried out in 2017. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the SMD, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13.b (for 10 kΩ). The results from the SMD and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.080 × 10-6 for 1 Ω and 0.068 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIMT (Thailand) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Khumthukthit, N.; Jassadajin, C.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NIMT (Thailand) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NIMT and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.20 × 10-6 for 1 Ω and 0.74 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Transformation of Learning in Education and Training: Key Qualifications Revisited. CEDEFOP Reference Series.

    ERIC Educational Resources Information Center

    Kamarainen, Pekka, Ed.; Attwell, Graham, Ed.; Brown, Alan, Ed.

    This book contains 15 papers examining European approaches to the theme of key qualifications. The following papers are included: "Key Qualifications Revisited: An Introduction" (Pekka Kamarainen); "Exploring Key Qualifications: Context, Theory, and Practice in Europe" (Pekka Kamarainen); "Rethinking Key Qualifications:…

  4. Knowledge Management and Reference Services

    ERIC Educational Resources Information Center

    Gandhi, Smiti

    2004-01-01

    Many corporations are embracing knowledge management (KM) to capture the intellectual capital of their employees. This article focuses on KM applications for reference work in libraries. It defines key concepts of KM, establishes a need for KM for reference services, and reviews various KM initiatives for reference services.

  5. Astrophysics of Reference Frame Tie Objects

    NASA Technical Reports Server (NTRS)

    Johnston, Kenneth J.; Boboltz, David; Fey, Alan Lee; Gaume, Ralph A.; Zacharias, Norbert

    2004-01-01

    The Astrophysics of Reference Frame Tie Objects Key Science program will investigate the underlying physics of SIM grid objects. Extragalactic objects in the SIM grid will be used to tie the SIM reference frame to the quasi-inertial reference frame defined by extragalactic objects and to remove any residual frame rotation with respect to the extragalactic frame. The current realization of the extragalactic frame is the International Celestial Reference Frame (ICRF). The ICRF is defined by the radio positions of 212 extragalactic objects and is the IAU sanctioned fundamental astronomical reference frame. This key project will advance our knowledge of the physics of the objects which will make up the SIM grid, such as quasars and chromospherically active stars, and relates directly to the stability of the SIM reference frame. The following questions concerning the physics of reference frame tie objects will be investigated.

  6. Key comparison BIPM.RI(I)-K5 of the air-kerma standards of the SMU, Slovakia and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    The first direct comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0051 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the MKEH, Hungary and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Machula, G.

    2018-01-01

    A comparison of the standards for air kerma of the Hungarian Trade Licensing Office (MKEH), Hungary and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in March 2016. The comparison result, evaluated as a ratio of the MKEH and the BIPM standards for air kerma, is 1.0047 with a combined standard uncertainty of 1.9 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2.6 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. KEY COMPARISON: Final report on CCPR K1-a: Spectral irradiance from 250 nm to 2500 nm

    NASA Astrophysics Data System (ADS)

    Woolliams, Emma R.; Fox, Nigel P.; Cox, Maurice G.; Harris, Peter M.; Harrison, Neil J.

    2006-01-01

    The CCPR K1-a key comparison of spectral irradiance (from 250 nm to 2500 nm) was carried out to meet the requirements of the Mutual Recognition Arrangement by 13 participating national metrology institutes (NMIs). Because of the fragile nature of the tungsten halogen lamps used as comparison artefacts, the comparison was arranged as a star comparison with three lamps per participant. NPL (United Kingdom) piloted the comparison and, by measuring all lamps, provided a link between participants' measurements. The other participants were BNM-INM (France), CENAM (Mexico), CSIRO (Australia), HUT (Finland), IFA-CSIC (Spain), MSL-IRL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NRC (Canada), PTB (Germany) and VNIIOFI (Russian Federation). Before the analysis was completed and the results known, the pilot discussed with each participant which lamp measurements should be included as representative of their comparison. As a consequence of this check, at least one measurement was excluded from one third of the lamps because of changes due to transportations. The comparison thus highlighted the difficulty regarding the availability of suitable transfer standards for the dissemination of spectral irradiance. The use of multiple lamps and multiple measurements ensured sufficient redundancy that all participants were adequately represented. In addition, during this pre-draft A phase all participants had the opportunity to review the uncertainty budgets and methods of all other participants. This new process helped to ensure that all submitted results and their associated uncertainties were evaluated in a consistent manner. The comparison was analysed using a model-based method which regarded each lamp as having a stable spectral irradiance and the measurements made by an NMI as systematically influenced by a factor that applies to all that NMI's measurements. The aim of the analysis was to estimate the systematic factor for each NMI. Across the

  9. Key comparison BIPM.RI(I)-K5 of the air kerma standards of the ININ, Mexico and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D. T.; Alvarez Romero, J. T.; De la Cruz Hernández, D.; Cabrera Vertti, M. R.; Tovar-Muñoz, V. M.

    2015-01-01

    A direct comparison of the standards for air kerma of the Instituto Nacional de Investigaciones Nucleares (ININ), Mexico, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in February 2015. The comparison result, evaluated as a ratio of the ININ and the BIPM standards for air kerma, is 1.0048 with a combined standard uncertainty of 2.0 × 10-3. The results are analysed and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the CMI (Czech Republic) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Kučera, J.; Chrobok, P.; Vo&jacute; čko&vacute; , L.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the CMI (Czech Republic) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the CMI and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.046 × 10-6 for 1 Ω and 0.034 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Power, O.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.16 × 10-6 for 1 Ω and 0.42 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the BIM (Bulgaria) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Tenev, A.; Hadzhistoykova, R.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the BIM (Bulgaria) and the BIPM carried out in 2013. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.30 × 10-6 at 10 kΩ and in reasonable agreement for 1 Ω with a relative difference of -0.18 × 10-6 with a relative expanded uncertainty of 0.17 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Report on NIM-NMC bilateral comparison: SPRT calibration comparison from -190°C to 420°C

    NASA Astrophysics Data System (ADS)

    Sun, Jianping; Ye, Shaochun; Wang, Li; Zhang, Jintao; Kho, Haoyuan

    2016-01-01

    A bilateral comparison of local realization of the International temperature scale of 1990 (ITS-90) between National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from -190°C to 420°C. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key comparison 3 (CCT-K3) and facilitate the NMC's Calibration and measurement capabilities (CMCs) submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme (APMP) in 2009, and registered in the Key Comparison Database (KCDB) in 2010 as CCT-K3.2. NMC supplied two 25 Ω fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn and Zn fixed points, while the other one was used at the Ar and Hg fixed point. NMC measured them before and after NIM measurement. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 Average Reference Value (ARV) using NIM as a link are reported with expanded uncertainties at each measured fixed point. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. KEY COMPARISON: CCQM-K61: Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA

    NASA Astrophysics Data System (ADS)

    Woolford, Alison; Holden, Marcia; Salit, Marc; Burns, Malcolm; Ellison, Stephen L. R.

    2009-01-01

    Key comparison CCQM-K61 was performed to demonstrate and document the capability of interested national metrology institutes in the determination of the quantity of specific DNA target in an aqueous solution. The study provides support for the following measurement claim: "Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA". The comparison was an activity of the Bioanalysis Working Group (BAWG) of the Comité Consultatif pour la Quantité de Matière and was coordinated by NIST (Gaithersburg, USA) and LGC (Teddington, UK). The following laboratories (in alphabetical order) participated in this key comparison. DMSC (Thailand); IRMM (European Union); KRISS (Republic of Korea); LGC (UK); NIM (China); NIST (USA); NMIA (Australia); NMIJ (Japan); VNIIM (Russian Federation) Good agreement was observed between the reported results of all nine of the participants. Uncertainty estimates did not account fully for the dispersion of results even after allowance for possible inhomogeneity in calibration materials. Preliminary studies suggest that the effects of fluorescence threshold setting might contribute to the excess dispersion, and further study of this topic is suggested Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. On-site comparison of Quantum Hall Effect resistance standards of METAS and the BIPM: Ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Mortara, Alessandro; Jeanneret, Blaise

    2018-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Federal Institute of Metrology METAS (Switzerland) and of the Bureau International des Poids et Mesures (BIPM) was made in December 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 5 parts in 1010 with a relative combined standard uncertainty uc = 23 × 10‑10. Scaling from 100 Ω to 10 kΩ has also been addressed through the measurement of a 10000 Ω/100 Ω ratio. The measurements carried out agreed to 2 parts in 1010 with a relative combined standard uncertainty uc = 19 × 10‑10. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Middle Atmosphere Program. Handbook for MAP. Volume 31: Reference models of trace species for the COSPAR international reference atmosphere

    NASA Technical Reports Server (NTRS)

    Keating, G. M. (Editor)

    1989-01-01

    A set of preliminary reference atmosphere models of significant trace species which play important roles in controlling the chemistry, radiation budget, and circulation patterns of the atmosphere were produced. These models of trace species distributions are considered to be reference models rather than standard models; thus, it was not crucial that they be correct in an absolute sense. These reference models can serve as a means of comparison between individual observations, as a first guess in inversion algorithms, and as an approximate representation of observations for comparison to theoretical calculations.

  17. Key comparison study on peptide purity—synthetic human C-peptide

    NASA Astrophysics Data System (ADS)

    Josephs, R. D.; Li, M.; Song, D.; Westwood, S.; Stoppacher, N.; Daireaux, A.; Choteau, T.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Flatschart, R.; Borges Oliveira, R.; Melanson, J. E.; Ohlendorf, R.; Henrion, A.; Kinumi, T.; Wong, L.; Liu, Q.; Oztug Senal, M.; Vatansever, B.; Ün, I.; Gören, A. C.; Akgöz, M.; Quaglia, M.; Warren, J.

    2017-01-01

    Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115, was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM). Eight Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of human C-peptide (hCP) present as the main component in the comparison sample for CCQM-K115. The comparison samples were prepared from synthetic human hCP purchased from a commercial supplier and used as provided without further treatment or purification. hCP was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of short (up to 5 kDa), non-cross-linked synthetic peptides/proteins. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used a peptide impurity corrected amino acid analysis (PICAA) approach as the amount of material that has been provided to each participant (25 mg) is insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, both the BIPM and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the hCP mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the hCP purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the hCP mass fraction. In particular it allows participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification

  18. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies--with specific reference to the measurement of cardiac output.

    PubMed

    Cecconi, Maurizio; Rhodes, Andrew; Poloniecki, Jan; Della Rocca, Giorgio; Grounds, R Michael

    2009-01-01

    Bland-Altman analysis is used for assessing agreement between two measurements of the same clinical variable. In the field of cardiac output monitoring, its results, in terms of bias and limits of agreement, are often difficult to interpret, leading clinicians to use a cutoff of 30% in the percentage error in order to decide whether a new technique may be considered a good alternative. This percentage error of +/- 30% arises from the assumption that the commonly used reference technique, intermittent thermodilution, has a precision of +/- 20% or less. The combination of two precisions of +/- 20% equates to a total error of +/- 28.3%, which is commonly rounded up to +/- 30%. Thus, finding a percentage error of less than +/- 30% should equate to the new tested technique having an error similar to the reference, which therefore should be acceptable. In a worked example in this paper, we discuss the limitations of this approach, in particular in regard to the situation in which the reference technique may be either more or less precise than would normally be expected. This can lead to inappropriate conclusions being drawn from data acquired in validation studies of new monitoring technologies. We conclude that it is not acceptable to present comparison studies quoting percentage error as an acceptability criteria without reporting the precision of the reference technique.

  19. Time evolution of an SLR reference frame

    NASA Astrophysics Data System (ADS)

    Angermann, D.; Gerstl, M.; Kelm, R.; Müller, H.; Seemüller, W.; Vei, M.

    2002-07-01

    On the basis of LAGEOS-1 and LAGEOS-2 data we computed a 10-years (1990-2000) solution for SLR station positions and velocities. The paper describes the data processing with the DGFI software package DOGS. We present results for station coordinates and their time variation for 41 stations of the global SLR network, and discuss the stability and time evolution of the SLR reference frame established in the same way. We applied different methods to assess the quality and consistency of the SLR results. The results presented in this paper include: (1) a time series of weekly estimated station coordinates; (2) a comparison of a 10-year LAGEOS-1 and LAGEOS-2 solution; (3) a comparison of 2.5-year solutions with the combined 10-year solution to assess the internal stability and the time evolution of the SLR reference frame; (4) a comparison of the SLR reference frame with ITRF97; and (5) a comparison of SLR station velocities with those of ITRF97 and NNR NUVEL-1A.

  20. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Report to the CCT on COOMET comparison COOMET.T-K3.1 (previously COOMET.T-S1): Key regional comparison of the national standards of temperature in the range from the triple point of water to the freezing point of zinc

    NASA Astrophysics Data System (ADS)

    Pokhodun, A. I.

    2010-01-01

    In the framework of the CIPM MRA, a first COOMET comparison "Comparison of the ITS-90 realizations in the range from 0.01 °C to 429.7485 °C (from the triple point of water to the freezing point of zinc)", registered in the KCDB under the identifier "COOMET.T-K3", was carried out in 2005-2007. Four national metrology institutes took part in this comparison: VNIIM (Russian Federation), SMU (Slovakia), BelGIM (Republic of Belarus) and NSC IM (Ukraine), and two of them (VNIIM and SMU) ensured the linkage with key comparisons CCT-K3 and CCT-K4, in order to disseminate the metrological equivalence to the measurement standards of NSC IM and BelGIM. NSC IM, however, had to withdraw its results, and at the meeting of Technical Committee T-10 of COOMET it was decided to carry out a supplementary bilateral comparison between VNIIM and the NSC IM for realization of the ITS-90 in the same range of temperature. This was registered in the KCDB under the identifier COOMET.T-S1 and measurements were performed in 2008-2009. From the results presented in this report, it is possible to draw the conclusion that the COOMET supplementary comparison COOMET.T-S1 demonstrates the CMC uncertainties claimed by the NSC IM for the melting point of gallium 0.236 mK (k = 2), and the freezing points of indium 1.040 mK (k = 2), tin 0.858 mK (k = 2) and zinc 0.944 mK (k = 2). In September 2012 the Working Group on key Comparisons (WG 7) of the CCT upgraded this comparison to a COOMET key comparison of the 'CCT-K3' type. It is now identified as COOMET.T-K3.1. In April 2013 this report was superseded by item 03006 in the Technical Supplement of 2013. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the IST-LPSR, Portugal and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Cardoso, J.

    2018-01-01

    A comparison of the standards for air kerma of the Instituto Superior Técnico, Laboratório de Proteção e Segurança Radiológica (IST-LPSR), Portugal and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in December 2015. The comparison result, evaluated as a ratio of the IST-LPSR and the BIPM standards for air kerma, is 1.0026 with a combined standard uncertainty of 1.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 1.1 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Analysis and comparison of NoSQL databases with an introduction to consistent references in big data storage systems

    NASA Astrophysics Data System (ADS)

    Dziedzic, Adam; Mulawka, Jan

    2014-11-01

    NoSQL is a new approach to data storage and manipulation. The aim of this paper is to gain more insight into NoSQL databases, as we are still in the early stages of understanding when to use them and how to use them in an appropriate way. In this submission descriptions of selected NoSQL databases are presented. Each of the databases is analysed with primary focus on its data model, data access, architecture and practical usage in real applications. Furthemore, the NoSQL databases are compared in fields of data references. The relational databases offer foreign keys, whereas NoSQL databases provide us with limited references. An intermediate model between graph theory and relational algebra which can address the problem should be created. Finally, the proposal of a new approach to the problem of inconsistent references in Big Data storage systems is introduced.

  4. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    NASA Astrophysics Data System (ADS)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Evaluation of alanine as a reference dosimeter for therapy level dose comparisons in megavoltage electron beams

    NASA Astrophysics Data System (ADS)

    McEwen, Malcolm; Sharpe, Peter; Vörös, Sándor

    2015-04-01

    When comparing absorbed dose standards from different laboratories (e.g. National Measurement Institutes, NMIs, for Key or Supplementary comparisons) it is rarely possible to carry out a direct comparison of primary standard instruments, and therefore some form of transfer detector is required. Historically, air-filled, unsealed ionization chambers have been used because of the long history of using these instruments, very good stability over many years, and ease of transport. However, the use of ion chambers for therapy-level comparisons is not without its problems. Findings from recent investigations suggest that ion chambers are prone to non-random variations, they are not completely robust to standard courier practices, and failure at any step in a comparison can render all measurements potentially useless. An alternative approach is to identify a transfer system that is insensitive to some of these concerns—effectively a dosimeter that is inexpensive, simple to use, robust, but with sufficient precision and of a size relevant to the disseminated quantity in question. The alanine dosimetry system has been successfully used in a number of situations as an audit dosimeter and therefore the purpose of this investigation was to determine whether alanine could also be used as the transfer detector for dosimetric comparisons, which require a lower value for the measurement uncertainty. A measurement protocol was developed for comparing primary standards of absorbed dose to water in high-energy electron beams using alanine pellets irradiated in a water-equivalent plastic phantom. A trial comparison has been carried out between three NMIs and has indicated that alanine is a suitable alternative to ion chambers, with the system used achieving a precision of 0.1%. Although the focus of the evaluation was on the performance of the dosimeter, the comparison results are encouraging, showing agreement at the level of the combined uncertainties (~0.6%). Based on this

  7. Morphological Comparison of U3O8 Ore Concentrates from Canada Key Lake and Namibia Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, Daniel S.; Tandon, Lav; Martinez, Patrick Thomas

    Uranium ore concentrates from two different sources were examined using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The ore powders are referred to as Namibia (id. no. 90036, LIMS id. no. 18775) and Canada Key Lake (id. no. 90019, LIMS id. no. 18774). Earlier work identified the ores as the U₃O₈ phase of uranium oxide using x-ray diffraction. Both sets of powders were in the form of dark brown to black powder fines. However, the Canada Key Lake concentrates contained larger chunks of material on the millimeter scale that were easily visible to the unaided eye. The powdersmore » were mounted for SEM examination by hand dispersing a small amount onto conductive sticky tape. Two types of applicators were used and compared: a fine-tipped spatula and a foam-tipped applicator. The sticky tape was on a standard SEM “tee” mount, which was tapped to remove loose contamination before being inserted into the SEM.« less

  8. Activity measurements of the radionuclide 124Sb by the LNE-LNHB, France for the ongoing comparison BIPM.RI(II)-K1.Sb-124

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Ratel, G.; Moune, M.; Bobin, C.

    2011-01-01

    In 2007, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of 124Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. International documentary standards and comparison of national physical measurement standards for the calibration of accelerometers

    NASA Astrophysics Data System (ADS)

    Evans, David J.

    2002-11-01

    The documentary standards defining internationally adopted methodologies and protocols for calibrating transducers used to measure vibration are currently developed under the International Organization for Standardization (ISO) Technical Committee 108 Sub Committee 3 (Use and calibration of vibration and shock measuring instruments). Recent revisions of the documentary standards on primary methods for the calibration of accelerometers used to measure rectilinear motion have been completed. These standards can be, and have been, used as references in the technical protocols of key international and regional comparisons between National Measurement Institutes (NMIs) on the calibration of accelerometers. These key comparisons are occurring in part as a result of the creation of the Mutual Recognition Arrangement between NMIs which has appendices that document the uncertainties, and the comparisons completed in support of the uncertainties, claimed by the National Laboratories that are signatories of the MRA. The measurements for the first international and the first Interamerican System of Metrology (SIM) regional key comparisons in vibration have been completed. These intercomparisons were promulgated via the relatively new Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM) and SIM Metrology Working Group (MWG) 9, respectively.

  10. Establishment of a New National Reference Ensemble of Water Triple Point Cells

    NASA Astrophysics Data System (ADS)

    Senn, Remo

    2017-10-01

    The results of the Bilateral Comparison EURAMET.T-K3.5 (w/VSL, The Netherlands) with the goal to link Switzerland's ITS-90 realization (Ar to Al) to the latest key comparisons gave strong indications for a discrepancy in the realization of the triple point of water. Due to the age of the cells of about twenty years, it was decided to replace the complete reference ensemble with new "state-of-the-art" cells. Three new water triple point cells from three different suppliers were purchased, as well as a new maintenance bath for an additional improvement of the realization. In several loops measurements were taken, each cell of both ensembles intercompared, and the deviations and characteristics determined. The measurements show a significant lower average value of the old ensemble of 0.59 ± 0.25 mK (k=2) in comparison with the new one. Likewise, the behavior of the old cells is very unstable with a drift downward during the realization of the triple point. Based on these results the impact of the new ensemble on the ITS-90 realization from Ar to Al was calculated and set in the context to performed calibrations and their related uncertainties in the past. This paper presents the instrumentation, cells, measurement procedure, results, uncertainties and impact of the new national reference ensemble of water triple point cells on the current ITS-90 realization in Switzerland.

  11. Comparisons between Common and Dedicated Reference Signals for MIMO Multiplexing Using Precoding in Evolved UTRA Downlink

    NASA Astrophysics Data System (ADS)

    Taoka, Hidekazu; Kishiyama, Yoshihisa; Higuchi, Kenichi; Sawahashi, Mamoru

    This paper presents comparisons between common and dedicated reference signals (RSs) for channel estimation in MIMO multiplexing using codebook-based precoding for orthogonal frequency division multiplexing (OFDM) radio access in the Evolved UTRA downlink with frequency division duplexing (FDD). We clarify the best RS structure for precoding-based MIMO multiplexing based on comparisons of the structures in terms of the achievable throughput taking into account the overhead of the common and dedicated RSs and the precoding matrix indication (PMI) signal. Based on extensive simulations on the throughput in 2-by-2 and 4-by-4 MIMO multiplexing with precoding, we clarify that channel estimation based on common RSs multiplied with the precoding matrix indicated by the PMI signal achieves higher throughput compared to that using dedicated RSs irrespective of the number of spatial multiplexing streams when the number of available precoding matrices, i.e., the codebook size, is less than approximately 16 and 32 for 2-by-2 and 4-by-4 MIMO multiplexing, respectively.

  12. Application Research of Horn Array Multi-Beam Antenna in Reference Source System for Satellite Interference Location

    NASA Astrophysics Data System (ADS)

    Zhou, Ping; Lin, Hui; Zhang, Qi

    2018-01-01

    The reference source system is a key factor to ensure the successful location of the satellite interference source. Currently, the traditional system used a mechanical rotating antenna which leaded to the disadvantages of slow rotation and high failure-rate, which seriously restricted the system’s positioning-timeliness and became its obvious weaknesses. In this paper, a multi-beam antenna scheme based on the horn array was proposed as a reference source for the satellite interference location, which was used as an alternative to the traditional reference source antenna. The new scheme has designed a small circularly polarized horn antenna as an element and proposed a multi-beamforming algorithm based on planar array. Moreover, the simulation analysis of horn antenna pattern, multi-beam forming algorithm and simulated satellite link cross-ambiguity calculation have been carried out respectively. Finally, cross-ambiguity calculation of the traditional reference source system has also been tested. The comparison between the results of computer simulation and the actual test results shows that the scheme is scientific and feasible, obviously superior to the traditional reference source system.

  13. Comparison of complementary and Kalman filter based data fusion for attitude heading reference system

    NASA Astrophysics Data System (ADS)

    Islam, Tariqul; Islam, Md. Saiful; Shajid-Ul-Mahmud, Md.; Hossam-E-Haider, Md

    2017-12-01

    An Attitude Heading Reference System (AHRS) provides 3D orientation of an aircraft (roll, pitch, and yaw) with instantaneous position and also heading information. For implementation of a low cost AHRS system Micro-electrical-Mechanical system (MEMS) based sensors are used such as accelerometer, gyroscope, and magnetometer. Accelerometers suffer from errors caused by external accelerations that sums to gravity and make accelerometers based rotation inaccurate. Gyroscopes can remove such errors but create drifting problems. So for getting the precise data additionally two very common and well known filters Complementary and Kalman are introduced to the system. In this paper a comparison of system performance using these two filters is shown separately so that one would be able to select filter with better performance for his/her system.

  14. Assessing Key Competences across the Curriculum--And Europe

    ERIC Educational Resources Information Center

    Pepper, David

    2011-01-01

    The development of key competences for lifelong learning has been an important policy imperative for EU Member States. The European Reference Framework of key competences (2006) built on previous developments by the OECD, UNESCO and Member States themselves. It defined key competences as knowledge, skills and attitudes applied appropriately to…

  15. Self-referenced continuous-variable quantum key distribution protocol

    DOE PAGES

    Soh, Daniel Beom Soo; Sarovar, Mohan; Brif, Constantin; ...

    2015-10-21

    We introduce a new continuous-variable quantum key distribution (CV-QKD) protocol, self-referenced CV-QKD, that eliminates the need for transmission of a high-power local oscillator between the communicating parties. In this protocol, each signal pulse is accompanied by a reference pulse (or a pair of twin reference pulses), used to align Alice’s and Bob’s measurement bases. The method of phase estimation and compensation based on the reference pulse measurement can be viewed as a quantum analog of intradyne detection used in classical coherent communication, which extracts the phase information from the modulated signal. We present a proof-of-principle, fiber-based experimental demonstration of themore » protocol and quantify the expected secret key rates by expressing them in terms of experimental parameters. Our analysis of the secret key rate fully takes into account the inherent uncertainty associated with the quantum nature of the reference pulse(s) and quantifies the limit at which the theoretical key rate approaches that of the respective conventional protocol that requires local oscillator transmission. The self-referenced protocol greatly simplifies the hardware required for CV-QKD, especially for potential integrated photonics implementations of transmitters and receivers, with minimum sacrifice of performance. Furthermore, it provides a pathway towards scalable integrated CV-QKD transceivers, a vital step towards large-scale QKD networks.« less

  16. Self-referenced continuous-variable quantum key distribution protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soh, Daniel Beom Soo; Sarovar, Mohan; Brif, Constantin

    We introduce a new continuous-variable quantum key distribution (CV-QKD) protocol, self-referenced CV-QKD, that eliminates the need for transmission of a high-power local oscillator between the communicating parties. In this protocol, each signal pulse is accompanied by a reference pulse (or a pair of twin reference pulses), used to align Alice’s and Bob’s measurement bases. The method of phase estimation and compensation based on the reference pulse measurement can be viewed as a quantum analog of intradyne detection used in classical coherent communication, which extracts the phase information from the modulated signal. We present a proof-of-principle, fiber-based experimental demonstration of themore » protocol and quantify the expected secret key rates by expressing them in terms of experimental parameters. Our analysis of the secret key rate fully takes into account the inherent uncertainty associated with the quantum nature of the reference pulse(s) and quantifies the limit at which the theoretical key rate approaches that of the respective conventional protocol that requires local oscillator transmission. The self-referenced protocol greatly simplifies the hardware required for CV-QKD, especially for potential integrated photonics implementations of transmitters and receivers, with minimum sacrifice of performance. Furthermore, it provides a pathway towards scalable integrated CV-QKD transceivers, a vital step towards large-scale QKD networks.« less

  17. Self-Referenced Continuous-Variable Quantum Key Distribution Protocol

    NASA Astrophysics Data System (ADS)

    Soh, Daniel B. S.; Brif, Constantin; Coles, Patrick J.; Lütkenhaus, Norbert; Camacho, Ryan M.; Urayama, Junji; Sarovar, Mohan

    2015-10-01

    We introduce a new continuous-variable quantum key distribution (CV-QKD) protocol, self-referenced CV-QKD, that eliminates the need for transmission of a high-power local oscillator between the communicating parties. In this protocol, each signal pulse is accompanied by a reference pulse (or a pair of twin reference pulses), used to align Alice's and Bob's measurement bases. The method of phase estimation and compensation based on the reference pulse measurement can be viewed as a quantum analog of intradyne detection used in classical coherent communication, which extracts the phase information from the modulated signal. We present a proof-of-principle, fiber-based experimental demonstration of the protocol and quantify the expected secret key rates by expressing them in terms of experimental parameters. Our analysis of the secret key rate fully takes into account the inherent uncertainty associated with the quantum nature of the reference pulse(s) and quantifies the limit at which the theoretical key rate approaches that of the respective conventional protocol that requires local oscillator transmission. The self-referenced protocol greatly simplifies the hardware required for CV-QKD, especially for potential integrated photonics implementations of transmitters and receivers, with minimum sacrifice of performance. As such, it provides a pathway towards scalable integrated CV-QKD transceivers, a vital step towards large-scale QKD networks.

  18. On-site comparison of Quantum Hall Effect resistance standards of the CMI and the BIPM: ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Kučera, Jan; Vojáčková, Lucie

    2017-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Czech Metrology Institute (CMI) and of the Bureau International des Poids et Mesures (BIPM) was made in April 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 6 parts in 1010 with a relative combined standard uncertainty uc = 25 × 10-10. Measurements of 10000 Ω/100 Ω and 100 Ω/1 Ω ratios agreed to 11 parts in 1010 with uc = 22 × 10-10 and to 33 parts in 1010 with uc = 32 × 10-10, respectively. The influence of the current reversal time has been systematically investigated in order to take into account possible errors due to the Peltier effect, which may be particularly large in 1 Ω standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Self- and Other-Referent Criteria of Career Success.

    ERIC Educational Resources Information Center

    Heslin, Peter A.

    2003-01-01

    Business students (n=71) evaluated their career success thus far. Framed by social comparison theory, results showed that 68% used other-referent criteria to assess their success. Participants who believed that ability and personality are fixed attributes had greater reliance on other-referent criteria. (Contains 100 references.) (SK)

  20. NTP comparison process

    NASA Technical Reports Server (NTRS)

    Corban, Robert

    1993-01-01

    The systems engineering process for the concept definition phase of the program involves requirements definition, system definition, and consistent concept definition. The requirements definition process involves obtaining a complete understanding of the system requirements based on customer needs, mission scenarios, and nuclear thermal propulsion (NTP) operating characteristics. A system functional analysis is performed to provide a comprehensive traceability and verification of top-level requirements down to detailed system specifications and provides significant insight into the measures of system effectiveness to be utilized in system evaluation. The second key element in the process is the definition of system concepts to meet the requirements. This part of the process involves engine system and reactor contractor teams to develop alternative NTP system concepts that can be evaluated against specific attributes, as well as a reference configuration against which to compare system benefits and merits. Quality function deployment (QFD), as an excellent tool within Total Quality Management (TQM) techniques, can provide the required structure and provide a link to the voice of the customer in establishing critical system qualities and their relationships. The third element of the process is the consistent performance comparison. The comparison process involves validating developed concept data and quantifying system merits through analysis, computer modeling, simulation, and rapid prototyping of the proposed high risk NTP subsystems. The maximum amount possible of quantitative data will be developed and/or validated to be utilized in the QFD evaluation matrix. If upon evaluation of a new concept or its associated subsystems determine to have substantial merit, those features will be incorporated into the reference configuration for subsequent system definition and comparison efforts.

  1. Supplement to CCM.D-K4 'Hydrometer' report: linkage of EURAMET.M.D-K4 comparison, SIM.M.D-K4 comparison and the supplementary SIM.M.D-S2 to CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.

    2017-01-01

    Evaluation of different types of comparisons to a common set of reference values of a CIPM key comparison is essential to satisfy the concept of the CIPM Mutual Recognition Arrangement (CIPM MRA), where the DoEs of any participant who took part in comparisons should be within the Calibration and Measurement Capability (CMC) section of the CIPM MRA Key Comparison Data Base. The subject of this supplementary report is therefore to present the equivalence of each National Metrological Institute (NMI) participant in the CCM.D-K4 'Hydrometer' key comparison, which was performed in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20 °C, and the linkage of the European and Inter-American NMI results performed in the RMO.M.D-K4 comparisons as well as those of the supplementary SIM.M.D-S2 to the common set of KCRVs of the CCM.D-K4 'Hydrometer'. The linking procedure has been obtained by numerical simulation, based on the Monte Carlo method, in which the differences in the results of the different comparison between the intended laboratory and one or more linking laboratory/ies, which took part in both comparisons, are correlated with a continuous function describing the DoEs of the linking laboratory/ies with respect to the common set of KCRVs of the CCM.D-K4. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. SUPPLEMENTARY COMPARISON: Final report on supplementary comparison APMP-T-S3-03 of industrial platinum resistance and liquid in glass thermometers from -40 °C to 250 °C

    NASA Astrophysics Data System (ADS)

    Norranim, Uthai; Nguyen, Mong Kim; Ballico, Mark J.

    2007-01-01

    Industrial thermometers such as industrial platinum resistance thermometers (iprts) and liquid-in-glass thermometers (LIGTs) are widely used in industry. Because Key Comparisons are limited to direct realizations of ITS-90, and not all APMP NMIs have participated in them, the national metrology institutes (NMIs) of Thailand and Australia (NIMT and NIMA) organized an APMP supplementary comparison to support the approval of CMCs (calibration and measurement capabilities) for these laboratories. The comparison, performed in 2003, covered the range from -40.0 °C to 250.0 °C, using IPRTs (Hart Scientific 5626-12-S), total immersion (ASTM 62C, 120C) and partial immersion (ASTM 40C) LIGTs. Ten NMIs from the APMP: KIM-LIPI (Indonesia), ITDI (Philippines), MSL (New Zealand), NBSM (Nepal), NMIA (Australia), NIMT (Thailand), SCL (Hong Kong), SIRIM (Malaysia), SPRING (Singapore) and VMI (Vietnam) were divided into two loops to shorten the circulation time, and these were linked by the two pilot laboratories. This report describes details of the artifacts, the circulation schedule, the measurement procedures, the results submitted by participants, uncertainties and the analysis of the results. Reference values calculated using simple mean, median and weighted mean were consistent with each other, but as the Birge criterion was satisfied, the weighted mean with its lower uncertainty was adopted. The artifacts were found to be stable over the comparison and the results of the loop linking labs consistent, allowing an uncertainty of 2 mK to 4 mK to be achieved for the IPRT reference value and 10 mK to 20 mK for the LIGT reference values. These uncertainties allowed the comparison data to be used to adequately test the uncertainties of all the participant laboratories, and hence to directly support their CMC claims. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database

  3. SUPPLEMENTARY COMPARISON: Final report on Supplementary Comparison APMP.M.H-S1

    NASA Astrophysics Data System (ADS)

    Kongkavitool, Rugkanawan; Hattori, Koichiro; Sanh, Vo; Yen, Lim Gin

    2007-01-01

    This report presents the results of supplementary comparison APMP.M.H-S1 among four national metrology institutes (NIMT, NMIJ/AIST, VMI and SPRING). The comparison was carried out during October 2004 to January 2005 in order to determine the capability of the primary Rockwell hardness standard, including standard conditions, of each participant, to confirm the accuracy of Rockwell hardness scale C measurement declared by the participant, which includes the effect of each participant's primary indenter and determine the degrees of equivalence of hardness scale measurement in the range 20 HRC to 60 HRC. Furthermore, the comparison was carried out a by common indenter, which was provided by the pilot institute, in order to determine the measurement capability of the participant's primary machine without the influence of the indenter, as a study of scientific purpose. The pilot institute was the National Institute of Metrology (Thailand), NIMT. There were two sets of artifacts for the comparison. Each set was composed of nine hardness blocks: 20 HRC, 25 HRC, 30 HRC, 35 HRC, 40 HRC, 45 HRC, 50 HRC, 55 HRC, 60 HRC. The verification of the participant's primary Rockwell hardness machine was carried out according to ISO6508-3 before making the measurement. The pilot institute made measurements at the beginning and the end of the comparison in order to monitor the stability of the artifacts. The degree of equivalence of each national primary hardness standard was expressed quantitatively by two terms, the deviation from KCRV and the uncertainty of this deviation at a 95% level of confidence. The En parameter was calculated to express the equivalence between the measurements of participants as well. The degree of equivalence between pairs of participating institutes was expressed by the difference of their deviations from the key comparison reference value and the uncertainty of this difference at the 95% level of confidence. Main text. To reach the main text of this paper

  4. Continuous variable quantum key distribution: finite-key analysis of composable security against coherent attacks.

    PubMed

    Furrer, F; Franz, T; Berta, M; Leverrier, A; Scholz, V B; Tomamichel, M; Werner, R F

    2012-09-07

    We provide a security analysis for continuous variable quantum key distribution protocols based on the transmission of two-mode squeezed vacuum states measured via homodyne detection. We employ a version of the entropic uncertainty relation for smooth entropies to give a lower bound on the number of secret bits which can be extracted from a finite number of runs of the protocol. This bound is valid under general coherent attacks, and gives rise to keys which are composably secure. For comparison, we also give a lower bound valid under the assumption of collective attacks. For both scenarios, we find positive key rates using experimental parameters reachable today.

  5. An ethnically relevant consensus Korean reference genome is a step towards personal reference genomes

    PubMed Central

    Cho, Yun Sung; Kim, Hyunho; Kim, Hak-Min; Jho, Sungwoong; Jun, JeHoon; Lee, Yong Joo; Chae, Kyun Shik; Kim, Chang Geun; Kim, Sangsoo; Eriksson, Anders; Edwards, Jeremy S.; Lee, Semin; Kim, Byung Chul; Manica, Andrea; Oh, Tae-Kwang; Church, George M.; Bhak, Jong

    2016-01-01

    Human genomes are routinely compared against a universal reference. However, this strategy could miss population-specific and personal genomic variations, which may be detected more efficiently using an ethnically relevant or personal reference. Here we report a hybrid assembly of a Korean reference genome (KOREF) for constructing personal and ethnic references by combining sequencing and mapping methods. We also build its consensus variome reference, providing information on millions of variants from 40 additional ethnically homogeneous genomes from the Korean Personal Genome Project. We find that the ethnically relevant consensus reference can be beneficial for efficient variant detection. Systematic comparison of human assemblies shows the importance of assembly quality, suggesting the necessity of new technologies to comprehensively map ethnic and personal genomic structure variations. In the era of large-scale population genome projects, the leveraging of ethnicity-specific genome assemblies as well as the human reference genome will accelerate mapping all human genome diversity. PMID:27882922

  6. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    NASA Astrophysics Data System (ADS)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Key Competencies. Second Edition.

    ERIC Educational Resources Information Center

    Haworth, David; Browne, Geoff

    Key competencies (or generic skills) have been specified in four sources: Further Education Unit (FEU), United Kingdom (1987); Finn Report (1991) and Mayer Committee (1992), Australia; U.S. Labor Secretary's Commission on Achieving Necessary Skills (SCANS) (June 1991); and Butterworth and Lovell (1983), New South Wales. A comparison of the four…

  8. Key volatile compounds in red koji-shochu, a Monascus-fermented product, and their formation steps during fermentation.

    PubMed

    Rahayu, Yen Yen Sally; Yoshizaki, Yumiko; Yamaguchi, Keiko; Okutsu, Kayu; Futagami, Taiki; Tamaki, Hisanori; Sameshima, Yoshihiro; Takamine, Kazunori

    2017-06-01

    Red koji, which refers the solid culture grown koji mold on the steamed rice, is one of the ingredients of Asian fermented foods including the Japanese spirit shochu. This study was aimed at elucidating the characteristic flavor and key volatile compounds of red koji-shochu as well as the mechanism of their formation. Sensory evaluation showed that red koji-shochu has the distinctive flavors cheese, sour, milky, and oily. Fifteen key volatile compounds of red koji-shochu were identified by gas chromatography-mass spectrometry and high-performance liquid chromatography, and by comparison between red koji-shochu and white koji-shochu, as another typical shochu. The mash analysis revealed that ketone compounds and short-chain acids derive from red koji. Furthermore, although other key compounds were produced by yeast, it is highly likely that their concentrations were affected directly or indirectly by the high activities of protease and lipase in red koji. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Final report on the key comparison, CCM.P-K15 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Arai, Kenta; Bergoglio, Mercede; Fedchak, James A.; Jousten, Karl; Hong, Seung Soo; Torres Guzman, Jorge

    2017-01-01

    The comparison CCM.P-K15 is a key comparison in pressure involving six laboratories in three regional metrological organizations (RMO). The measurand of the comparison is the accommodation coefficient of two spinning rotating gauge characterized in nitrogen from 0.1 mPa up to 1.0 Pa. The two transfer standards were circulated from November 2009 until March 2011. The circulation consisted of three loops, one for each RMO, and a new calibration by the pilot be-tween each loop. The stability of one of the transfer standards was poor and was worse than expected based on the previous history of the transfer standard while the other transfer standard demonstrated good stability while circulated in Europe and America and a fair stability while circulated in Asia. All the participants demonstrated equivalence to the definition of pressure in their respective primary standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. A soil sampling reference site: the challenge in defining reference material for sampling.

    PubMed

    de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto; van der Perk, Marcel

    2008-11-01

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations.

  11. Toward a Last Interglacial Compilation Using a Tephra-based Chronology: a Future Reference For Model-data Comparison

    NASA Astrophysics Data System (ADS)

    Bazin, L.; Govin, A.; Capron, E.; Nomade, S.; Lemieux-Dudon, B.; Landais, A.

    2017-12-01

    The Last Interglacial (LIG, 129-116 ka) is a key period to decipher the interactions between the different components of the climate system under warmer-than-preindustrial conditions. Modelling the LIG climate is now part of the CMIP6/PMIP4 targeted simulations. As a result, recent efforts have been made to propose surface temperature compilations focusing on the spatio-temporal evolution of the LIG climate, and not only on its peak warmth as previously proposed. However, the major limitation of these compilations remains in the climatic alignment of records (e.g. temperature, foraminiferal δ18O) that is performed to define the sites' chronologies. Such methods prevent the proper discussion of phase relationship between the different sites. Thanks to recent developments of the Bayesian Datice dating tool, we are now able to build coherent multi-archive chronologies with a proper propagation of the associated uncertainties. We make the best use of common tephra layers identified in well-dated continental archives and marine sediment cores of the Mediterranean region to propose a coherent chronological framework for the LIG independent of any climatic assumption. We then extend this precise chronological context to the North Atlantic as a first step toward a global coherent compilation of surface temperature and stable isotope records. Based on this synthesis, we propose guidelines for the interpretation of different proxies measured from different archives that will be compared with climate model parameters. Finally, we present time-slices (e.g. 127 ka) of the preliminary regional synthesis of temperature reconstructions and stable isotopes to serve as reference for future model-data comparison of the up-coming CMIP6/PMIP4 LIG simulations.

  12. Development of Composite Honeycomb and Solid Laminate Reference Standards to Aid Aircraft Inspections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorrell, L.; Roach, D.

    1999-03-04

    The rapidly increasing use of composites on commercial airplanes coupled with the potential for economic savings associated with their use in aircraft structures means that the demand for composite materials technology will continue to increase. Inspecting these composite structures is a critical element in assuring their continued airworthiness. The FAA's Airworthiness Assurance NDI Validation Center, in conjunction with the Commercial Aircraft Composite Repair Committee (CACRC), is developing a set of composite reference standards to be used in NDT equipment calibration for accomplishment of damage assessment and post-repair inspection of all commercial aircraft composites. In this program, a series of NDImore » tests on a matrix of composite aircraft structures and prototype reference standards were completed in order to minimize the number of standards needed to carry out composite inspections on aircraft. Two tasks, related to composite laminates and non-metallic composite honeycomb configurations, were addressed. A suite of 64 honeycomb panels, representing the bounding conditions of honeycomb construction on aircraft, were inspected using a wide array of NDI techniques. An analysis of the resulting data determined the variables that play a key role in setting up NDT equipment. This has resulted in a prototype set of minimum honeycomb reference standards that include these key variables. A sequence of subsequent tests determined that this minimum honeycomb reference standard set is able to fully support inspections over the fill range of honeycomb construction scenarios. Current tasks are aimed at optimizing the methods used to engineer realistic flaws into the specimens. In the solid composite laminate arena, we have identified what appears to be an excellent candidate, G11 Phenolic, as a generic solid laminate reference standard material. Testing to date has determined matches in key velocity and acoustic impedance properties, as well as, low attenuation

  13. Body mass index and childhood obesity classification systems: A comparison of the French, International Obesity Task Force (IOTF) and World Health Organization (WHO) references.

    PubMed

    Kêkê, L M; Samouda, H; Jacobs, J; di Pompeo, C; Lemdani, M; Hubert, H; Zitouni, D; Guinhouya, B C

    2015-06-01

    This study aims to compare three body mass index (BMI)-based classification systems of childhood obesity: the French, the International Obesity Task Force (IOTF) and the World Health Organization (WHO) references. The study involved 1382 schoolchildren, recruited from the Lille Academic District in France in May 2009 aged 8.4±1.7 years (4.0-12.0 years). Their mean height and body mass were 131.5±10.9cm and 30.7±9.2kg, respectively, resulting in a BMI of 17.4±3.2kg/m(2). The weight status was defined according to the three systems considered in this study. The agreement between these references was tested using the Cohen's kappa coefficient. The prevalence of overweight was higher with the WHO references (20.0%) in comparison with the French references (13.8%; P<0.0001) and the IOTF (16.2%; P≤0.01). A similar result was found with obesity (WHO: 11.6% vs. IOTF: 6.7%; or French references: 6.7%; P<0.0001). Agreement between the three references ranged from "moderate" to "perfect" (0.43≤κ≤1.00; P<0.0001). Kappa coefficients were higher when the three references were used to classify children as obese (0.63≤κ≤1.00; P<0.0001) as compared to classification in the overweight (obesity excluded) category (0.43≤κ≤0.94; P<0.0001). When sex and age categories (4-6 years vs. 7-12 years) were considered to define the overweight status, the lowest kappa coefficient was found between the French and WHO references in boys aged 7-12 years (κ=0.28; P<0.0001), and the highest one in girls aged 7-12 years between the French references and IOTF (κ=0.97; P<0.0001). As for obesity, agreement between the three references ranged from 0.60 to 1.00 (P<0.0001), with the lowest values obtained in the comparison of the WHO references against French references or IOTF among boys aged 7-12 years (κ=0.60; P<0.0001). Overall, the WHO references yield an overestimation in overweight and/or obesity within this sample of schoolchildren as compared to the French references and the

  14. Comparison of measurement standards of the acoustic pressure in air in the low frequency range: COOMET.AUV.A-K2

    NASA Astrophysics Data System (ADS)

    Chalyy, V.

    2011-01-01

    A bilateral regional comparison of national microphone standards from 2 Hz to 250 Hz was carried out between the DP NDI 'Systema' (Ukraine) and the VNIIFTRI (Russia) from July to September 2009. The comparison, COOMET.AUV.A-K2, was based on the pressure calibration of laboratory standard microphones type LSIP. The comparison results have been linked to the established key comparison reference value (KCRV) of CCAUV.A-K2. The degrees of equivalence, expressed as the deviation from the established KCRV and its expanded uncertainty (k = 2), have been determined, and the comparison result is in agreement with the KCRV within the estimated uncertainties at all employed frequencies. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. Signaling Network of Environmental Sensing and Adaptation in Plants:. Key Roles of Calcium Ion

    NASA Astrophysics Data System (ADS)

    Kurusu, Takamitsu; Kuchitsu, Kazuyuki

    2011-01-01

    Considering the important issues concerning food, environment, and energy that humans are facing in the 21st century, humans mostly depend on plants. Unlike animals which move from an inappropriate environment, plants do not move, but rapidly sense diverse environmental changes or invasion by other organisms such as pathogens and insects in the place they root, and adapt themselves by changing their own bodies, through which they developed adaptability. Whole genetic information corresponding to the blueprints of many biological systems has recently been analyzed, and comparative genomic studies facilitated tracing strategies of each organism in their evolutional processes. Comparison of factors involved in intracellular signal transduction between animals and plants indicated diversification of different gene sets. Reversible binding of Ca2+ to sensor proteins play key roles as a molecular switch both in animals and plants. Molecular mechanisms for signaling network of environmental sensing and adaptation in plants will be discussed with special reference to Ca2+ as a key element in information processing.

  16. Self-referenced continuous-variable quantum key distribution

    DOEpatents

    Soh, Daniel B. S.; Sarovar, Mohan; Camacho, Ryan

    2017-01-24

    Various technologies for continuous-variable quantum key distribution without transmitting a transmitter's local oscillator are described herein. A receiver on an optical transmission channel uses an oscillator signal generated by a light source at the receiver's location to perform interferometric detection on received signals. An optical reference pulse is sent by the transmitter on the transmission channel and the receiver computes a phase offset of the transmission based on quadrature measurements of the reference pulse. The receiver can then compensate for the phase offset between the transmitter's reference and the receiver's reference when measuring quadratures of received data pulses.

  17. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -25 °C TO +20 °C.

    PubMed

    Meyer, C W; Hill, K D

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC.

  18. Subjective Social Status and Well-Being: The Role of Referent Abstraction.

    PubMed

    Haught, Heather M; Rose, Jason; Geers, Andrew; Brown, Jill A

    2015-01-01

    Subjective social status (SSS) has been shown to predict well-being and mental health, above and beyond objective social status (OSS). However, little is known about the factors that moderate this relationship. Two studies explored whether the link between SSS and well-being varied depending upon the referent used for comparison in SSS judgments. Participants judged their well-being and SSS in comparison to referents that varied in abstraction. A confirmatory factor analysis on SSS judgments yielded two factors: (a) SSS perceptions toward global referents and (b) SSS perceptions toward local referents. SSS relative to a global referent was a better predictor of depression (Studies 1 and 2), life satisfaction (Studies 1 and 2), and self-esteem (Study 2) than SSS relative to a local referent. These findings have theoretical implications for understanding how people differentiate between local vs. global referents and practical implications for status-related health disparities.

  19. A Novel Multiple-Access Correlation-Delay-Shift-Keying

    NASA Astrophysics Data System (ADS)

    Duan, J. Y.; Jiang, G. P.; Yang, H.

    In Correlation-Delay-Shift-Keying (CDSK), the reference signal and the information-bearing signal are added together during a certain time delay. Because the reference signal is not strictly orthogonal to the information-bearing signal, the cross-correlation between the adjacent chaotic signal (Intra-signal Interference, ISI) will be introduced into the demodulation at the receiver. Therefore, the Bit-Error Ratio (BER) of CDSK is higher than that of Differential-Chaos-Shift-Keying (DCSK). To avoid the ISI component and enhance the BER performance of CDSK in multiuser scenario, Multiple-Access CDSK with No Intra-signal Interference (MA-CDSK-NII) is proposed. By constructing the repeated chaotic generator and applying the Walsh code sequence to modulate the reference signal, in MA-CDSK-NII, the ISI component will be eliminated during the demodulation. Gaussian approximation method is adopted here to obtain the exact performance analysis of MA-CDSK-NII over additive white Gaussian noise (AWGN) channel and Rayleigh multipath fading channels. Results show that, due to no ISI component and lower transmitting power, the BER performance of MA-CDSK-NII can be better than that of multiple-access CDSK and Code-Shifted Differential-Chaos-Shift-Keying (CS-DCSK).

  20. Learning from other people’s fear: amygdala-based social reference learning in social anxiety disorder

    PubMed Central

    Blair, K. S.; Otero, M.; Teng, C.; Geraci, M.; Lewis, E.; Hollon, N.; Blair, R. J. R.; Ernst, Monique; Grillon, C.; Pine, D. S.

    2016-01-01

    Background Social anxiety disorder involves fear of social objects or situations. Social referencing may play an important role in the acquisition of this fear and could be a key determinant in future biomarkers and treatment pathways. However, the neural underpinnings mediating such learning in social anxiety are unknown. Using event-related functional magnetic resonance imaging, we examined social reference learning in social anxiety disorder. Specifically, would patients with the disorder show increased amygdala activity during social reference learning, and further, following social reference learning, show particularly increased response to objects associated with other people’s negative reactions? Method A total of 32 unmedicated patients with social anxiety disorder and 22 age-, intelligence quotient- and gender-matched healthy individuals responded to objects that had become associated with others’ fearful, angry, happy or neutral reactions. Results During the social reference learning phase, a significant group × social context interaction revealed that, relative to the comparison group, the social anxiety group showed a significantly greater response in the amygdala, as well as rostral, dorsomedial and lateral frontal and parietal cortices during the social, relative to non-social, referencing trials. In addition, during the object test phase, relative to the comparison group, the social anxiety group showed increased bilateral amygdala activation to objects associated with others’ fearful reactions, and a trend towards decreased amygdala activation to objects associated with others’ happy and neutral reactions. Conclusions These results suggest perturbed observational learning in social anxiety disorder. In addition, they further implicate the amygdala and dorsomedial prefrontal cortex in the disorder, and underscore their importance in future biomarker developments. PMID:27476529

  1. Key Issues in Instructional Computer Graphics.

    ERIC Educational Resources Information Center

    Wozny, Michael J.

    1981-01-01

    Addresses key issues facing universities which plan to establish instructional computer graphics facilities, including computer-aided design/computer aided manufacturing systems, role in curriculum, hardware, software, writing instructional software, faculty involvement, operations, and research. Thirty-seven references and two appendices are…

  2. KEY COMPARISON: Final report on CCQM-K62: Nutrients in infant/adult formula—Vitamins

    NASA Astrophysics Data System (ADS)

    Sharpless, Katherine E.; Rimmer, Catherine A.; Phinney, Karen W.; Nelson, Bryant C.; Duewer, David L.; Wise, Stephen A.; Kim, Byungjoo; Liu, Jun; Huang, Ting; Zhang, Wei

    2010-01-01

    Key comparison CCQM-K62 was designed to enable demonstration of the equivalence in capabilities for measurement of vitamins in a food matrix. A milk-based fortified human infant/adult formula was selected as the matrix based upon material availability and relevance. Because vitamins were added to the CCQM-K62 study material in a single form and at levels significantly higher than those that would be naturally occurring in the milk base, the ability of a laboratory to measure the study vitamins is only indicative of a laboratory's ability to measure vitamins in fortified foods. Target analytes were selected for study because of the ready availability of suitable standard materials and the range of their chemical properties: folic acid (vitamin B9) is a single water-soluble molecular entity that typically occurs at low levels and can be unstable, niacin (vitamin B3) is a single stable molecular entity and is typically present at higher concentrations than the other water-soluble vitamins, vitamin A has multiple molecular forms (including retinol and retinyl palmitate), is fat-soluble and typically occurs at relatively high levels. Results for participants measuring only folic acid or niacin are only indicative of their ability to make that measurement; results for participants measuring both folic acid and niacin are indicative of a laboratory's ability to measure folic acid, thiamine, niacin, and riboflavin in fortified foods but not vitamin C or other water-soluble vitamins. The ability to measure vitamin A (reported as retinol equivalents) in this material is also indicative of the participant's ability to measure vitamin E (as alpha-tocopherol and alpha-tocopheryl acetate) but is not indicative of the ability to measure vitamins D and K, which typically occur at much lower concentrations. The relative degrees of equivalence of the reported measurements for all three analytes in CCQM-K62 were within 10%; however, since only two results were submitted for niacin

  3. KEY COMPARISON: Final report of APMP.T-K6 (original name APMP-IC-1-97): Comparison of humidity measurements using a dew point meter as a transfer standard

    NASA Astrophysics Data System (ADS)

    Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.

    2007-01-01

    This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. ClinicalKey: a point-of-care search engine.

    PubMed

    Vardell, Emily

    2013-01-01

    ClinicalKey is a new point-of-care resource for health care professionals. Through controlled vocabulary, ClinicalKey offers a cross section of resources on diseases and procedures, from journals to e-books and practice guidelines to patient education. A sample search was conducted to demonstrate the features of the database, and a comparison with similar tools is presented.

  5. Drug Lag and Key Regulatory Barriers in the Emerging Markets

    PubMed Central

    Wileman, Harriet; Mishra, Arun

    2010-01-01

    There have been numerous investigations targeted at identifying whether a drug lag exists in the mature markets of the US, EU and Japan. This work focuses on the emerging markets because of the potential they hold for the future of the pharmaceutical industry as a consequence of rapid economic and political development. The aims of this work are to ascertain whether a drug lag exists in the emerging markets and how it has changed over time from the 1960s to the 2000s. It will also highlight key regulatory barriers which may contribute to drug lag. The date of the marketing authorisation (MA) approval by the US Food and Drug Administration (FDA) was used as a reference point. A comparison against the company database regarding emerging market specific approval enabled the difference in time and thus the drug lag for that particular market to be calculated. This work concludes that the overall relative drug lag in the emerging markets has decreased over time and that there are seven key regulatory barriers which need to be targeted in order to make further improvements; ‘Western Approval’, local clinical development (LCD), Certificate of Pharmaceutical Product (CPP), Good Manufacturing Practice (GMP), pricing approval, document authentication and harmonisation. PMID:21829782

  6. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −25 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Hill, K.D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952

  7. The effect of reference choices on the spatio-temporal analysis of brain evoked potentials: the use of infinite reference.

    PubMed

    Yao, Dezhong; Wang, Li; Arendt-Nielsen, Lars; Chen, Andrew C N

    2007-11-01

    Reference is a very virtual issue in EEG and ERP. Understanding the difference of various references will make the applications more confident. In this work, somatosensory evoked potential (SEP) with stimulation on the right hand was studied. The SEP spatio-temporal analysis was conducted comparatively on six references, left mastoid (contralateral mastoid reference, CM), right mastoid (ipsilateral mastoid reference, IM), linked mastoids (LM), average reference (AR), vertex reference (Cz) and the infinity reference (IR) newly proposed in 2001. Among the six, CM is the one used in actual recordings, and the other five are obtained by off-line re-referencing. The comparison is conducted on four selected components (P30 ms, P40 ms, N90 ms and P230 ms) in both temporal and spatial aspects. The results show that references may have a distinct influence on the amplitudes of the scalp potentials, with relative error at some electrodes larger than 500%, and for some electrodes it may even change the polarity. Pair-wise multiple comparison (Tukey test) shows that the differences of peak values among various references are very significant (P<0.001) between Cz and IR\\CM\\IM\\LM, and significant (P<0.01) between Cz and AR for component N90 ms; very significant (P<0.001) between Cz and IR\\CM\\IM\\LM\\AR, significant between IMLM and AR (P<0.01), CM and AR (P<0.05) for component P230 ms. The amplitude value order is CM/IM> or =LM>IR>AR>Cz. The two-ways (the six references vs. the four Peaks) repeated measures ANOVA test shows the effect of different references depends on various components; there is a statistically significant interaction between reference and the peak (P=<0.001). While for the spatial map of the potential amplitude, references will not affect the amplitude map shape if the color-bar is selected automatically, but if a fixed color-bar is chosen for data of various references, they may show some differences. These results mean a common reference is important

  8. Final report on CCT-K6: Comparison of local realisations of dew-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.

    2015-01-01

    A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report on VMI-NMISA bilateral comparison APMP.T-K3.1: Realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans

    2012-01-01

    The Comité Consulatif de Thermométrie (CCT) has organized several key comparisons to compare realizations of the ITS-90 in different National Metrology Institutes. To keep the organization, time scale and data processing of such a comparison manageable, the number of participants in a CCT key comparison (CCT KC) is limited to a few laboratories in each major economic region. Subsequent regional key comparisons are linked to the applicable CCT KC by two or more linking laboratories. For the temperature range from 83.8058 K (triple point of Ar) to 933.473 K (freezing point of Al), a key comparison, CCT-K3, was carried out from 1997 to 2001 among representative laboratories in North America, Europe and Asia. Following CCT-K3, the Asia-Pacific Metrology Program Key Comparison 3 (APMP.T-K3) was organized for National Metrology Institutes in the Asia/Pacific region. NMIA (Australia) and KRISS (South Korea) provided the link between CCT-K3 and APMP.T-K3. APMP.T-K3, which took place from February 2000 to June 2003, covered the temperature range from -38.8344 °C (triple point of Hg) to 419.527 °C (freezing point of Zn), using a standard platinum resistance thermometer (SPRT) as the artefact. In June 2007 the Vietnam Metrology Institute (VMI) requested a bilateral comparison to link their SPRT calibration capabilities to APMP.T-K3, and in October 2007 the National Metrology Institute of South Africa (NMISA) agreed to provide the link to APMP.T-K3. Like APMP.T-K3, the comparison was restricted to the Hg to Zn temperature range to reduce the chance of drift in the SPRT artefact. The comparison was carried out in a participant-pilot-participant topology (with NMISA as the pilot and VMI as the participant). VMI's results in the comparison were linked to the Average Reference Values of CCT-K3 via NMISA's results in APMP.T-K3. The resistance ratios measured by VMI and NMISA at Zn, Sn, Ga and Hg fixed points agree within their combined uncertainties, and VMI's results also

  10. Reference View Selection in DIBR-Based Multiview Coding.

    PubMed

    Maugey, Thomas; Petrazzuoli, Giovanni; Frossard, Pascal; Cagnazzo, Marco; Pesquet-Popescu, Beatrice

    2016-04-01

    Augmented reality, interactive navigation in 3D scenes, multiview video, and other emerging multimedia applications require large sets of images, hence larger data volumes and increased resources compared with traditional video services. The significant increase in the number of images in multiview systems leads to new challenging problems in data representation and data transmission to provide high quality of experience on resource-constrained environments. In order to reduce the size of the data, different multiview video compression strategies have been proposed recently. Most of them use the concept of reference or key views that are used to estimate other images when there is high correlation in the data set. In such coding schemes, the two following questions become fundamental: 1) how many reference views have to be chosen for keeping a good reconstruction quality under coding cost constraints? And 2) where to place these key views in the multiview data set? As these questions are largely overlooked in the literature, we study the reference view selection problem and propose an algorithm for the optimal selection of reference views in multiview coding systems. Based on a novel metric that measures the similarity between the views, we formulate an optimization problem for the positioning of the reference views, such that both the distortion of the view reconstruction and the coding rate cost are minimized. We solve this new problem with a shortest path algorithm that determines both the optimal number of reference views and their positions in the image set. We experimentally validate our solution in a practical multiview distributed coding system and in the standardized 3D-HEVC multiview coding scheme. We show that considering the 3D scene geometry in the reference view, positioning problem brings significant rate-distortion improvements and outperforms the traditional coding strategy that simply selects key frames based on the distance between cameras.

  11. Implementation of Telemedicine and Stroke Network in thrombolytic administration: comparison between walk-in and referred patients.

    PubMed

    Dharmasaroja, Pornpatr A; Muengtaweepongsa, Sombat; Kommarkg, Urai

    2010-08-01

    The purpose of this study was to evaluate the efficacy and safety of implementation of telemedicine and the Thammasat Stroke Network model in treating acute ischemic stroke patients with intravenous thrombolysis. Telemedicine (telephone consultation and tele-radiology) has been used in acute ischemic stroke management since June, 2007. The Thammasat Stroke Network (TSN) was effectively organized in March, 2008. Thammasat Hospital served as a "hub" hospital, with 25 "spoke" hospitals in the TSN. The main outcome measures included favorable outcome of the patients treated with intravenous tissue plasminogen activator (tPA) at 3 months and symptomatic intracerebral hemorrhage by comparison between walk-in patients and the patients who were referred by the TSN. There were 14 patients (14 out of 170 acute ischemic stroke patients, 8%) and 110 patients (110 out of 406 patients, 27%) receiving tPA, before and after implementation of TSN, respectively. Walk-in patients (66 patients) had significant shorter onset-to-treatment duration as compared with referred patients (58 patients) (130 vs. 170 min, P < 0.0001). However, there was no significant difference in favorable outcome (48 vs. 42%, P = 0.538) and rate of symptomatic intracerebral hemorrhage (3 vs. 2%, P = 0.637). Implementation of telemedicine and TSN markedly increased tPA administrations, without compromising favorable and safety outcomes.

  12. Final report on the torque key komparison CCM.T-K1.2 measurand torque: 0 N.m, 500 N.m, 1000 N.m

    NASA Astrophysics Data System (ADS)

    Röske, Dirk

    2015-01-01

    The purpose of the CIPM subsequent bilateral comparison CCM.T-K1.2 was to link another participant, namely the National Institute of Metrology (Thailand), in short NIMT, to the CCM.T-K1 torque key comparison. The measuring capabilities up to 1000 N.m of dead-weight torque standard machines with supported lever were investigated. The pilot laboratory was the same in both comparisons—it was the Physikalisch-Technische Bundesanstalt (PTB, Braunschweig, Germany). The same two very stable torque transducers with well-known properties were used as travelling standards. The measurements at the participating laboratory were carried out between November 2007 and February 2008. According to the technical protocol, torque steps of 500 N.m and 1000 N.m had to be measured both in clockwise and anticlockwise directions. Corrections had to be applied to the results reported by the participants taking into account the use of different amplifiers, the creep (due to different loading times of the machines) and the environmental conditions in the laboratories (temperature and relative humidity of the ambient air). The results of the pilot laboratory in this bilateral comparison are in very good agreement with the same results obtained in the CCM.T-K1 comparison. For each of the transducers, the two torque steps and both senses of direction of the torque vector, the key comparison reference value of the CCM.T-K1 was taken, and the results of participant NIMT were calculated with respect to these values. The agreement between the results is very good. The smallest expanded (k = 2) relative uncertainty of the machine stated by the participant is 1 × 10-4. The results of the comparison support this uncertainty statement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according

  13. Perceptual quality estimation of H.264/AVC videos using reduced-reference and no-reference models

    NASA Astrophysics Data System (ADS)

    Shahid, Muhammad; Pandremmenou, Katerina; Kondi, Lisimachos P.; Rossholm, Andreas; Lövström, Benny

    2016-09-01

    Reduced-reference (RR) and no-reference (NR) models for video quality estimation, using features that account for the impact of coding artifacts, spatio-temporal complexity, and packet losses, are proposed. The purpose of this study is to analyze a number of potentially quality-relevant features in order to select the most suitable set of features for building the desired models. The proposed sets of features have not been used in the literature and some of the features are used for the first time in this study. The features are employed by the least absolute shrinkage and selection operator (LASSO), which selects only the most influential of them toward perceptual quality. For comparison, we apply feature selection in the complete feature sets and ridge regression on the reduced sets. The models are validated using a database of H.264/AVC encoded videos that were subjectively assessed for quality in an ITU-T compliant laboratory. We infer that just two features selected by RR LASSO and two bitstream-based features selected by NR LASSO are able to estimate perceptual quality with high accuracy, higher than that of ridge, which uses more features. The comparisons with competing works and two full-reference metrics also verify the superiority of our models.

  14. The automated reference toolset: A soil-geomorphic ecological potential matching algorithm

    USGS Publications Warehouse

    Nauman, Travis; Duniway, Michael C.

    2016-01-01

    Ecological inventory and monitoring data need referential context for interpretation. Identification of appropriate reference areas of similar ecological potential for site comparison is demonstrated using a newly developed automated reference toolset (ART). Foundational to identification of reference areas was a soil map of particle size in the control section (PSCS), a theme in US Soil Taxonomy. A 30-m resolution PSCS map of the Colorado Plateau (366,000 km2) was created by interpolating ∼5000 field soil observations using a random forest model and a suite of raster environmental spatial layers representing topography, climate, general ecological community, and satellite imagery ratios. The PSCS map had overall out of bag accuracy of 61.8% (Kappa of 0.54, p < 0.0001), and an independent validation accuracy of 93.2% at a set of 356 field plots along the southern edge of Canyonlands National Park, Utah. The ART process was also tested at these plots, and matched plots with the same ecological sites (ESs) 67% of the time where sites fell within 2-km buffers of each other. These results show that the PSCS and ART have strong application for ecological monitoring and sampling design, as well as assessing impacts of disturbance and land management action using an ecological potential framework. Results also demonstrate that PSCS could be a key mapping layer for the USDA-NRCS provisional ES development initiative.

  15. KEY COMPARISON: CCEM.RF-K18.CL (GT-RF/00-1): Noise in 50 Ω coaxial line at frequencies up to 1 GHz

    NASA Astrophysics Data System (ADS)

    Eiø, Christopher; Adamson, David; Randa, James; Allal, Djamel; Uzdin, Rinadij

    2006-01-01

    A measurement comparison of noise temperature has been carried out between four national metrology laboratories in coaxial line at 30 MHz, 60 MHz and 1 GHz. The identification of this intercomparison is CCEM.RF-K18.CL. Two noise sources have been measured. The following four national laboratories participated in this intercomparison: NPL (United Kingdom), NIST (United States of America), BNM-LNE (France) and VNIIFTRI (Russia). The National Physical Laboratory (UK) acted as the pilot laboratory for the comparison. It can be seen that there is generally good agreement between the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    PubMed

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  17. Enterprise Reference Library

    NASA Technical Reports Server (NTRS)

    Bickham, Grandin; Saile, Lynn; Havelka, Jacque; Fitts, Mary

    2011-01-01

    Introduction: Johnson Space Center (JSC) offers two extensive libraries that contain journals, research literature and electronic resources. Searching capabilities are available to those individuals residing onsite or through a librarian s search. Many individuals have rich collections of references, but no mechanisms to share reference libraries across researchers, projects, or directorates exist. Likewise, information regarding which references are provided to which individuals is not available, resulting in duplicate requests, redundant labor costs and associated copying fees. In addition, this tends to limit collaboration between colleagues and promotes the establishment of individual, unshared silos of information The Integrated Medical Model (IMM) team has utilized a centralized reference management tool during the development, test, and operational phases of this project. The Enterprise Reference Library project expands the capabilities developed for IMM to address the above issues and enhance collaboration across JSC. Method: After significant market analysis for a multi-user reference management tool, no available commercial tool was found to meet this need, so a software program was built around a commercial tool, Reference Manager 12 by The Thomson Corporation. A use case approach guided the requirements development phase. The premise of the design is that individuals use their own reference management software and export to SharePoint when their library is incorporated into the Enterprise Reference Library. This results in a searchable user-specific library application. An accompanying share folder will warehouse the electronic full-text articles, which allows the global user community to access full -text articles. Discussion: An enterprise reference library solution can provide a multidisciplinary collection of full text articles. This approach improves efficiency in obtaining and storing reference material while greatly reducing labor, purchasing and

  18. Final report of key comparison AFRIMETS.AUV.A-K5: primary pressure calibration of LS1P microphones according to IEC 61094-2, over the frequency range 2 Hz to 10 kHz.

    NASA Astrophysics Data System (ADS)

    Nel, R.; Avison, J.; Harris, P.; Blabla, M.; Hämäläinen, J.

    2017-01-01

    The degrees of equivalence of the AFRIMETS.AUV.A-K5 regional key comparison are reported here as the final report. The scope of the comparison covered the complex pressure sensitivities of two LS1P microphones over the frequency range 2 Hz to 10 kHz in accordance with IEC 61094-2: 2009. Four national metrology institutes from two different regional metrology organisations participated in the comparison. Two LS1P microphones were circulated simultaneously to all the participants in a circular configuration. One of the microphones sensitivity shifted and all results associated with this microphone were subsequently excluded from further analysis and linking. The AFRIMETS.AUV.A-K5 comparison results were linked to the CCAUV.A-K5 comparison results via dual participation in the CCAUV.A-K5 and AFRIMETS.AUV.A-K5 comparisons. The degrees of equivalence, linked to the CCAUV.A-K5 comparison, were calculated for all participants of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. What Are the Key Statistics about Brain and Spinal Cord Cancers?

    MedlinePlus

    ... Brain and Spinal Cord Tumors in Adults Key Statistics for Brain and Spinal Cord Tumors The American ... Cord Tumors . Visit the American Cancer Society’s Cancer Statistics Center for more key statistics. Written by References ...

  20. Comparison of sexual dysfunction in women with infertility and without infertility referred to Al-Zahra Hospital in 2013-2014

    PubMed Central

    Mirblouk, Fariba; Asgharnia, Dr.Maryam; Solimani, Robabeh; Fakor, Fereshteh; Salamat, Fatemeh; Mansoori, Samaneh

    2016-01-01

    Background: One of the affected aspects in infertile women that have not been given sufficient attention is sexual function. Sexual function is a key factor in physical and marital health, and sexual dysfunction could significantly lower the quality of life. Aim of this study was to assess the comparison sexual dysfunction in women with infertility and without infertility, admitted to Al- Zahra Hospital. Objective: We decided to assess the prevalence of women sexual disorders in fertile and infertile subjects, admitted to Al-Zahra Hospital. Materials and Methods: 149 fertile and 147 infertile women who referred to infertility clinic of Al-Zahra Hospital during 2013-2014 were entered this cross-sectional study and Female Sexual Function Index questionnaire (FSFI) had been filled by all the cases. Most of women were married for 6-10 years (35.5%) and mean marriage time in participants was 9.55±6.07 years. Data were analyzed using SPSS software Ver. 18 and 2 test and logistic regression model has been used for analysis. Results: Results showed significant differences between desire (p=0.004), arousal (p=0.001), satisfaction (p=0.022) and total sexual dysfunction (p=0.011) in both groups but in lubrication (p=0.266), orgasm (p=0.61) and pain (p=0.793) difference were not significant. Conclusion: Some of sexual dysfunction indices are high in all infertile women. Our findings suggest that infertility impacts on women’s sexual function in desire, arousal, satisfaction and total sexual dysfunction. Health care professional should be sensitive to impact that diagnosis of infertility can have on women’s sexuality. PMID:27200426

  1. Reference interval estimation: Methodological comparison using extensive simulations and empirical data.

    PubMed

    Daly, Caitlin H; Higgins, Victoria; Adeli, Khosrow; Grey, Vijay L; Hamid, Jemila S

    2017-12-01

    To statistically compare and evaluate commonly used methods of estimating reference intervals and to determine which method is best based on characteristics of the distribution of various data sets. Three approaches for estimating reference intervals, i.e. parametric, non-parametric, and robust, were compared with simulated Gaussian and non-Gaussian data. The hierarchy of the performances of each method was examined based on bias and measures of precision. The findings of the simulation study were illustrated through real data sets. In all Gaussian scenarios, the parametric approach provided the least biased and most precise estimates. In non-Gaussian scenarios, no single method provided the least biased and most precise estimates for both limits of a reference interval across all sample sizes, although the non-parametric approach performed the best for most scenarios. The hierarchy of the performances of the three methods was only impacted by sample size and skewness. Differences between reference interval estimates established by the three methods were inflated by variability. Whenever possible, laboratories should attempt to transform data to a Gaussian distribution and use the parametric approach to obtain the most optimal reference intervals. When this is not possible, laboratories should consider sample size and skewness as factors in their choice of reference interval estimation method. The consequences of false positives or false negatives may also serve as factors in this decision. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Reference in human and non-human primate communication: What does it take to refer?

    PubMed

    Sievers, Christine; Gruber, Thibaud

    2016-07-01

    The concept of functional reference has been used to isolate potentially referential vocal signals in animal communication. However, its relatedness to the phenomenon of reference in human language has recently been brought into question. While some researchers have suggested abandoning the concept of functional reference altogether, others advocate a revision of its definition to include contextual cues that play a role in signal production and perception. Empirical and theoretical work on functional reference has also put much emphasis on how the receiver understands the referential signal. However, reference, as defined in the linguistic literature, is an action of the producer, and therefore, any definition describing reference in non-human animals must also focus on the producer. To successfully determine whether a signal is used to refer, we suggest an approach from the field of pragmatics, taking a closer look at specific situations of signal production, specifically at the factors that influence the production of a signal by an individual. We define the concept of signaller's reference to identify intentional acts of reference produced by a signaller independently of the communicative modality, and illustrate it with a case study of the hoo vocalizations produced by wild chimpanzees during travel. This novel framework introduces an intentional approach to referentiality. It may therefore permit a closer comparison of human and non-human animal referential behaviour and underlying cognitive processes, allowing us to identify what may have emerged solely in the human lineage.

  3. Micronutrient content in enteral nutrition formulas: comparison with the dietary reference values for healthy populations.

    PubMed

    Iacone, Roberto; Scanzano, Clelia; Santarpia, Lidia; D'Isanto, Anna; Contaldo, Franco; Pasanisi, Fabrizio

    2016-03-31

    The micronutrient content in standard enteral mixtures should be closer to the dietary reference values for a healthy population since standard enteral diets are formulated for subjects with no special nutritional needs. This study compares the micronutrient content of the most common enteral nutrition (EN) formulas with European dietary reference values (DRVs) for healthy population. Sixty-two nutritionally complete enteral formulas were considered. The micronutrient content was calculated by multiplying the value reported on the nutritional information panel of each formula by the daily dose usually prescribed. The comparison between the micronutrient content of all enteral formulas evaluated and the DRVs indicates that daily fluoride and vitamin K requirements were not covered, while an oversupply of many other micronutrients was provided. Moreover, in some enteral formulas, at a dose of 2000 Kcal/day, zinc and vitamin A content exceeded the tolerable upper limits and, for one diabetes-specific enteral formula, the chromium content exceeded the relevant European standards in both 1500 and 2000 Kcal/day diets. Most enteral formulas evaluated are generally suitable for patients on long-term total EN and formulas with higher content of a specific micronutrient may be a useful tool for patients affected by specific clinical conditions, at least for a period of time, then switching to standard enteral mixtures. The availability of nutritional enteral formulas, well balanced also for micronutrient intake, will further improve individualized treatments, particularly for patients on long-term total EN.

  4. Reference Values for Spirometry Derived Using Lambda, Mu, Sigma (LMS) Method in Korean Adults: in Comparison with Previous References.

    PubMed

    Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul

    2018-01-15

    The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.

  5. Approaches to defining reference regimes for river restoration planning

    NASA Astrophysics Data System (ADS)

    Beechie, T. J.

    2014-12-01

    Reference conditions or reference regimes can be defined using three general approaches, historical analysis, contemporary reference sites, and theoretical or empirical models. For large features (e.g., floodplain channels and ponds) historical data and maps are generally reliable. For smaller features (e.g., pools and riffles in small tributaries), field data from contemporary reference sites are a reasonable surrogate for historical data. Models are generally used for features that have no historical information or present day reference sites (e.g., beaver pond habitat). Each of these approaches contributes to a watershed-wide understanding of current biophysical conditions relative to potential conditions, which helps create not only a guiding vision for restoration, but also helps quantify and locate the largest or most important restoration opportunities. Common uses of geomorphic and biological reference conditions include identifying key areas for habitat protection or restoration, and informing the choice of restoration targets. Examples of use of each of these three approaches to define reference regimes in western USA illustrate how historical information and current research highlight key restoration opportunities, focus restoration effort in areas that can produce the largest ecological benefit, and contribute to estimating restoration potential and assessing likelihood of achieving restoration goals.

  6. Context controls access to working and reference memory in the pigeon (Columba livia).

    PubMed

    Roberts, William A; Macpherson, Krista; Strang, Caroline

    2016-01-01

    The interaction between working and reference memory systems was examined under conditions in which salient contextual cues were presented during memory retrieval. Ambient colored lights (red or green) bathed the operant chamber during the presentation of comparison stimuli in delayed matching-to-sample training (working memory) and during the presentation of the comparison stimuli as S+ and S- cues in discrimination training (reference memory). Strong competition between memory systems appeared when the same contextual cue appeared during working and reference memory training. When different contextual cues were used, however, working memory was completely protected from reference memory interference. © 2016 Society for the Experimental Analysis of Behavior.

  7. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S1

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S2

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Construction of a New Growth References for China Based on Urban Chinese Children: Comparison with the WHO Growth Standards

    PubMed Central

    Zong, Xin-Nan; Li, Hui

    2013-01-01

    Introduction Growth references for Chinese children should be updated due to the positive secular growth trends and the progress of the smoothing techniques. Human growth differs among the various ethnic groups, so comparison of the China references with the WHO standards helps to understand such differences. Methods The China references, including weight, length/height, head circumference, weight-for-length/height and body mass index (BMI) aged 0–18 years, were constructed based on 69,760 urban infants and preschool children under 7 years and 24,542 urban school children aged 6–20 years derived from two cross-sectional national surveys. The Cole’s LMS method is employed for smoothing the growth curves. Results The merged data sets resulted in a smooth transition at age 6–7 years and continuity of curves from 0 to 18 years. Varying differences were found on the empirical standard deviation (SD) curves in each indicator at nearly all ages between China and WHO. The most noticeable differences occurred in genders, final height and boundary centiles curves. Chinese boys’ weight is strikingly heavier than that of the WHO at age 6–10 years. The height is taller than that of the WHO for boys below 15 years and for girls below 13, but is significantly lower when boys over 15 years and girls over 13. BMI is generally higher than that of the WHO for boys at age 6–16 years but appreciably lower for girls at 3–18 years. Conclusions The differences between China and WHO are mainly caused by the reference populations of different ethnic backgrounds. For practitioners, the choices of the standards/references depend on the population to be assessed and the purpose of the study. The new China references could be applied to facilitate the standardization assessment of growth and nutrition for Chinese children and adolescents in clinical pediatric and public health. PMID:23527219

  10. National and international veterinary reference laboratories for infectious diseases.

    PubMed

    Edwards, S; Alexander, D

    1998-08-01

    Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.

  11. EURAMET.M.P-S9: comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Saxholm, S.; Otal, P.; AltintaS, A.; Bermanec, L. G.; Durgut, Y.; Hanrahan, R.; Kocas, I.; Lefkopoulos, A.; Pražák, D.; Sandu, I.; Åetina, J.; Spohr, I.; Steindl, D.; Tammik, K.; Testa, N.

    2016-01-01

    A comparison in the negative gauge pressure range was arranged in the period 2011 - 2012. A total of 14 laboratories participated in this comparison: BEV (Austria), CMI (Czech Republic), DANIAmet-FORCE (Denmark), EIM (Greece), HMI/FSB-LPM (Croatia), INM (Romania), IPQ (Portugal), LNE (France), MCCAA (Malta), METROSERT (Estonia), MIKES (Finland), MIRS/IMT/LMT (Slovenia), NSAI (Ireland) and UME (Turkey). The project was divided into two loops: Loop1, piloted by MIKES, and Loop2, piloted by LNE. The results of the two loops are reported separately: Loop1 results are presented in this paper. The transfer standard was Beamex MC5 no. 25516865 with internal pressure module INT1C, resolution 0.01 hPa. The nominal pressure range of the INT1C is -1000 hPa to +1000 hPa. The nominal pressure points for the comparison were 0 hPa, -200 hPa, -400 hPa, -600 hPa, -800 hPa and -950 hPa. The reference values and their uncertainties as well as the difference uncertainty between the laboratory results and the reference values were determined from the measurement data by Monte Carlo simulations. Stability uncertainty of the transfer standard was included in the final difference uncertainty. Degrees of equivalences and mutual equivalences between the laboratories were calculated. Each laboratory reported results for all twelve measurement points, which means that there were 168 reported values in total. Some 163 of the 168 values (97 %) agree with the reference values within the expanded uncertainties, with a coverage factor k = 2. Among the laboratories, four different methods were used to determine negative gauge pressure. It is concluded that special attention must be paid to the measurements and methods when measuring negative gauge pressures. There might be a need for a technical guide or a workshop that provides information about details and practices related to the measurements of negative gauge pressure, as well as differences between the different methods. The comparison is

  12. Astronomical catalog desk reference, 1994 edition

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The Astronomical Catalog Desk Reference is designed to aid astronomers in locating machine readable catalogs in the Astronomical Data Center (ADC) archives. The key reference components of this document are as follows: A listing of shortened titles for all catalogs available from the ADC (includes the name of the lead author and year of publication), brief descriptions of over 300 astronomical catalogs, an index of ADC catalog numbers by subject keyword, and an index of ADC catalog numbers by author. The heart of this document is the set of brief descriptions generated by the ADC staff. The 1994 edition of the Astronomical Catalog Desk Reference contains descriptions for over one third of the catalogs in the ADC archives. Readers are encouraged to refer to this section for concise summaries of those catalogs and their contents.

  13. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  14. Improved reference models for middle atmosphere ozone

    NASA Technical Reports Server (NTRS)

    Keating, G. M.; Pitts, M. C.; Chen, C.

    1989-01-01

    Improvements are provided for the ozone reference model which is to be incorporated in the COSPAR International Reference Atmosphere (CIRA). The ozone reference model will provide considerable information on the global ozone distribution, including ozone vertical structure as a function of month and latitude from approximately 25 to 90 km, combining data from five recent satellite experiments (Nimbus 7 LIMS, Nimbus 7 SBUV, AE-2 SAGE, Solar Mesosphere Explorer (SME) UVS, and SME IR). The improved models are described and use reprocessed AE-2 SAGE data (sunset) and extend the use of SAGE data from 1981 to the period 1981-1983. Comparisons are shown between the ozone reference model and various nonsatellite measurements at different levels in the middle atmosphere.

  15. It Is Not Just about the Schedule: Key Factors in Effective Reference Desk Scheduling and Management

    ERIC Educational Resources Information Center

    Sciammarella, Susan; Fernandes, Maria Isabel; McKay, Devin

    2008-01-01

    Reference desk scheduling is one of the most challenging tasks in the organizational structure of an academic library. The ability to turn this challenge into a workable and effective function lies with the scheduler and indirectly the cooperation of all librarians scheduled for reference desk service. It is the scheduler's sensitivity to such…

  16. The role of observational reference data for climate downscaling: Insights from the VALUE COST Action

    NASA Astrophysics Data System (ADS)

    Kotlarski, Sven; Gutiérrez, José M.; Boberg, Fredrik; Bosshard, Thomas; Cardoso, Rita M.; Herrera, Sixto; Maraun, Douglas; Mezghani, Abdelkader; Pagé, Christian; Räty, Olle; Stepanek, Petr; Soares, Pedro M. M.; Szabo, Peter

    2016-04-01

    VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of downscaling methods. Such assessments can be expected to crucially depend on the existence of accurate and reliable observational reference data. In dynamical downscaling, observational data can influence model development itself and, later on, model evaluation, parameter calibration and added value assessment. In empirical-statistical downscaling, observations serve as predictand data and directly influence model calibration with corresponding effects on downscaled climate change projections. We here present a comprehensive assessment of the influence of uncertainties in observational reference data and of scale-related issues on several of the above-mentioned aspects. First, temperature and precipitation characteristics as simulated by a set of reanalysis-driven EURO-CORDEX RCM experiments are validated against three different gridded reference data products, namely (1) the EOBS dataset (2) the recently developed EURO4M-MESAN regional re-analysis, and (3) several national high-resolution and quality-controlled gridded datasets that recently became available. The analysis reveals a considerable influence of the choice of the reference data on the evaluation results, especially for precipitation. It is also illustrated how differences between the reference data sets influence the ranking of RCMs according to a comprehensive set of performance measures.

  17. Activity measurements of the radionuclides 18F and 64Cu for the NIST, USA in the ongoing comparisons BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Nonis, M.; Bergeron, D.; Cessna, J.; Fitzgerald, R.; Pibida, L.; Zimmerman, B.; Fenwick, A.; Ferreira, K.; Keightley, J.; Da Silva, I.

    2017-01-01

    In 2016, comparisons of activity measurements of 18F and 64Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for 64Cu. Ampoules containing about 27 kBq of 18F and 100 kBq of 64Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)β-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for 18F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Deducing trapdoor primitives in public key encryption schemes

    NASA Astrophysics Data System (ADS)

    Pandey, Chandra

    2005-03-01

    Semantic security of public key encryption schemes is often interchangeable with the art of building trapdoors. In the frame of reference of Random Oracle methodology, the "Key Privacy" and "Anonymity" has often been discussed. However to a certain degree the security of most public key encryption schemes is required to be analyzed with formal proofs using one-way functions. This paper evaluates the design of El Gamal and RSA based schemes and attempts to parallelize the trapdoor primitives used in the computation of the cipher text, thereby magnifying the decryption error δp in the above schemes.

  19. Quality Management and Key Performance Indicators in Oncologic Esophageal Surgery.

    PubMed

    Gockel, Ines; Ahlbrand, Constantin Johannes; Arras, Michael; Schreiber, Elke Maria; Lang, Hauke

    2015-12-01

    Ranking systems and comparisons of quality and performance indicators will be of increasing relevance for complex "high-risk" procedures such as esophageal cancer surgery. The identification of evidence-based standards relevant for key performance indicators in esophageal surgery is essential for establishing monitoring systems and furthermore a requirement to enhance treatment quality. In the course of this review, we analyze the key performance indicators case volume, radicality of resection, and postoperative morbidity and mortality, leading to continuous quality improvement. Ranking systems established on this basis will gain increased relevance in highly complex procedures within the national and international comparison and furthermore improve the treatment of patients with esophageal carcinoma.

  20. A common reference-based indirect comparison meta-analysis of eslicarbazepine versus lacosamide as add on treatments for focal epilepsy.

    PubMed

    Brigo, Francesco; Trinka, Eugen; Bragazzi, Nicola Luigi; Nardone, Raffaele; Milan, Alberto; Grillo, Elisabetta

    2016-11-01

    Eslicarbazepine acetate (ESL) and lacosamide (LCM) have recently emerged as add-on treatments in patients with focal epilepsy experiencing seizures despite adequate monotherapy. Both drugs enhance slow inactivation of voltage-gated sodium channels. To date no randomized controlled trial (RCT) has directly compared ESL with LCM as add-on treatments for focal epilepsy. Our aim was to indirectly compare the efficacy of ESL and LCM used as add-on treatments in patients with focal epilepsy using common reference-based indirect comparison meta-analysis. We systematically searched RCTs in which ESL or LCM has been used as add-on treatment in patients with focal epilepsy and compared with placebo. Following outcomes were considered: ≥50% reduction in seizure frequency; seizure freedom; treatment withdrawal for any reason; ≥25% increase in seizure frequency. Random-effects Mantel-Haenszel meta-analyses were performed to obtain odds ratios (ORs) for the efficacy of ESL or LCM versus placebo. Adjusted indirect comparisons were then made between ESL and LCM using the obtained results, and comparing the minimum and the highest effective recommended daily dose of each drug. Eight studies were included. Indirect comparisons adjusted for dose-effect showed no difference between ESL and LCM for responder rate, seizure freedom, and withdrawal rates. We could not assess increase in seizure frequency due to lack of data. Indirect comparisons failed to find a significant difference in efficacy between add-on ESL and LCM in patients with focal epilepsy. Direct head-to-head clinical trials comparing ESL with LCM as add-on antiepileptic treatment are required to confirm these results. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Results of Second Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, I.; Grobner, J.; Wacker, S.

    The Absolute Cavity Pyrgeometer (ACP) and InfraRed Integrating Sphere radiometer (IRIS) are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are un-windowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The second outdoor comparison between the two designs was held from September 30 to October 11, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of the IRIS was within 1 W/m2 (3 IRISs: PMOD + Australia + Germany). From the first and second comparisons, a differencemore » of 4-6 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG). This presentation includes results from the first and second comparison in an effort to establish the world reference for pyrgeometer calibrations, a key deliverable for the World Meteorological Organization (WMO), and the DOE-ASR.« less

  2. Paired Comparisons.

    DTIC Science & Technology

    1982-05-01

    including multidimensional scaling. Applications have arisen in many areas, but most notably in food technolog, marketing research, and sports ... competition .- An extensive bibliography on paired comparisons by Davidson and Farquhar (1976) contains some 400 references. - Paired comparisons have been...consideration of chess competition . Ford (1957) pro- posed the model independently. Both Zermelo and Ford concentrated on solution of normal equations for

  3. A visual identification key utilizing both gestalt and analytic approaches to identification of Carices present in North America (Plantae, Cyperaceae)

    PubMed Central

    2013-01-01

    Abstract Images are a critical part of the identification process because they enable direct, immediate and relatively unmediated comparisons between a specimen being identified and one or more reference specimens. The Carices Interactive Visual Identification Key (CIVIK) is a novel tool for identification of North American Carex species, the largest vascular plant genus in North America, and two less numerous closely-related genera, Cymophyllus and Kobresia. CIVIK incorporates 1288 high-resolution tiled image sets that allow users to zoom in to view minute structures that are crucial at times for identification in these genera. Morphological data are derived from the earlier Carex Interactive Identification Key (CIIK) which in turn used data from the Flora of North America treatments. In this new iteration, images can be viewed in a grid or histogram format, allowing multiple representations of data. In both formats the images are fully zoomable. PMID:24723777

  4. Final report on the Seventh International Comparison of Absolute Gravimeters (ICAG 2005)

    USGS Publications Warehouse

    Jiang, Z.; Francis, O.; Vitushkin, L.; Palinkas, V.; Germak, A.; Becker, M.; D'Agostino, G.; Amalvict, M.; Bayer, R.; Bilker-Koivula, M.; Desogus, S.; Faller, J.; Falk, R.; Hinderer, J.; Gagnon, C.; Jakob, T.; Kalish, E.; Kostelecky, J.; Lee, C.; Liard, J.; Lokshyn, Y.; Luck, B.; Makinen, J.; Mizushima, S.; Le, Moigne N.; Origlia, C.; Pujol, E.R.; Richard, P.; Robertsson, L.; Ruess, D.; Schmerge, D.; Stus, Y.; Svitlov, S.; Thies, S.; Ullrich, C.; Van Camp, M.; Vitushkin, A.; Ji, W.; Wilmes, H.

    2011-01-01

    The Bureau International des Poids et Mesures (BIPM), S??vres, France, hosted the 7th International Comparison of Absolute Gravimeters (ICAG) and the associated Relative Gravity Campaign (RGC) from August to September 2005. ICAG 2005 was prepared and performed as a metrological pilot study, which aimed: To determine the gravity comparison reference values; To determine the offsets of the absolute gravimeters; and As a pilot study to accumulate experience for the CIPM Key Comparisons. This document presents a complete and extensive review of the technical protocol and data processing procedures. The 1st ICAG-RGC comparison was held at the BIPM in 1980-1981 and since then meetings have been organized every 4 years. In this paper, we present an overview of how the meeting was organized, the conditions of BIPM gravimetric sites, technical specifications, data processing strategy and an analysis of the final results. This 7th ICAG final report supersedes all previously published reports. Readings were obtained from participating instruments, 19 absolute gravimeters and 15 relative gravimeters. Precise levelling measurements were carried out and all measurements were performed on the BIPM micro-gravity network which was specifically designed for the comparison. ?? 2011 BIPM & IOP Publishing Ltd.

  5. International comparison CCQM-K101: oxygen in nitrogen—a track B comparison and that the matrix contains argon

    NASA Astrophysics Data System (ADS)

    Zhou, Z.; Han, Q.; Wang, D.; Macé, T.; Kipphardt, H.; Maiwald, M.; Tuma, D.; Uehara, S.; Akima, D.; Shimosaka, T.; Jung, J.; Oh, S.-H.; van der Veen, A.; van Wijk, J. I. T.; Ziel, P. R.; Konopelko, L.; Valkova, M.; Mogale, David M.; Botha, A.; Brewer, P.; Murugan, A.; Doval Minnaro, M.; Miller, M.; Guenther, F.; Kelly, M. E.

    2016-01-01

    This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Royer, Michael P.

    A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of themore » CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.« less

  7. Polarization-basis tracking scheme for quantum key distribution using revealed sifted key bits.

    PubMed

    Ding, Yu-Yang; Chen, Wei; Chen, Hua; Wang, Chao; Li, Ya-Ping; Wang, Shuang; Yin, Zhen-Qiang; Guo, Guang-Can; Han, Zheng-Fu

    2017-03-15

    The calibration of the polarization basis between the transmitter and receiver is an important task in quantum key distribution. A continuously working polarization-basis tracking scheme (PBTS) will effectively promote the efficiency of the system and reduce the potential security risk when switching between the transmission and calibration modes. Here, we proposed a single-photon level continuously working PBTS using only sifted key bits revealed during an error correction procedure, without introducing additional reference light or interrupting the transmission of quantum signals. We applied the scheme to a polarization-encoding BB84 QKD system in a 50 km fiber channel, and obtained an average quantum bit error rate (QBER) of 2.32% and a standard derivation of 0.87% during 24 h of continuous operation. The stable and relatively low QBER validates the effectiveness of the scheme.

  8. Criminal investigation of child sexual abuse: a comparison of cases referred to the prosecutor to those not referred.

    PubMed

    Stroud, D D; Martens, S L; Barker, J

    2000-05-01

    The present study sought to identify characteristics of child sexual abuse cases which differentiate cases referred for criminal prosecution ("criminal-action") from those not referred ("dropped") by investigators. The study sample consisted of 1043 children who completed a forensic interview for sexual abuse that allegedly occurred at the hands of an adult between January 1, 1993 and December 31, 1996 in Bernalillo County of New Mexico. Data was systematically obtained from forensic interview files and offender records at the local prosecutor's office. Differences between criminal-action and dropped cases were found in relation to the children (age, sex and ethnicity), the alleged offenders (age, sex and relationship to child), and the case characteristics (disclosure and injury to the child). The present study provided insight into the characteristics of a previously ignored population (reported child sexual abuse cases that are not referred for prosecution). Recommendations are made to address the needs of these children and their families.

  9. Comparison of reference doses (RfDs) developed for the protection of wildlife species in contrast to humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valoppi, L.; Carlisle, J.; Polisini, J.

    1995-12-31

    A component of both human health and ecological risk assessments is the evaluation of toxicity values. A comparison between the methodology for the development of Reference Doses (RfDs) to be protective of humans, and that developed for vertebrate wildlife species is presented. For all species, a chronic No Observable Adverse Effect Level (NOAEL) is developed by applying uncertainty factors (UFs) to literature-based toxicity values. Uncertainty factors are used to compensate for the length of exposure, sensitivity of endpoints, and cross-species extrapolations between the test species and the species being assessed. Differences between human and wildlife species could include the toxicologicalmore » endpoint, the critical study, and the magnitude of the cross-species extrapolation factor. Case studies for select chemicals are presented which contrast RfDs developed for humans and those developed for avian and mammalian wildlife.« less

  10. [Characterization and comparison of interferon reference standards using UPLC-MS].

    PubMed

    Tao, Lei; Pei, De-ning; Han, Chun-mei; Chen, Wei; Rao, Chun-ming; Wang, Jun-zhi

    2015-01-01

    The study aims to characterize and compare interferon reference standards from 5 manufacturers. By testing molecular mass and trypsin-digested peptide mass mapping, the amino acid sequence was verified and post-translational modifications such as disulfide bond were identified. Results show that the molecular mass and amino acid sequence were consistent with theory; the disulfide bonds of 4 lots of interferon were Cys1-Cys98/Cys29-Cys138, 1 lot was Cys29-Cys139/Cys86-Cys99; N-terminal "+Met", acetyl N-terminal and Met oxidation were identified in part of the sample. UPLC-MS can be used to characterize and compare interferon reference standards from different manufacturers.

  11. Serum chemistry reference ranges for Steller sea lion (Eumetopias jubatus) pups from Alaska: stock differentiation and comparisons within a North Pacific sentinel species.

    PubMed

    Lander, Michelle E; Fadely, Brian S; Gelatt, Thomas S; Rea, Lorrie D; Loughlin, Thomas R

    2013-12-01

    Blood chemistry and hematologic reference ranges are useful for population health assessment and establishing a baseline for future comparisons in the event of ecosystem changes due to natural or anthropogenic factors. The objectives of this study were to determine if there was any population spatial structure for blood variables of Steller sea lion (Eumetopias jubatus), an established sentinel species, and to report reference ranges for appropriate populations using standardized analyses. In addition to comparing reference ranges between populations with contrasting abundance trends, data were examined for evidence of disease or nutritional stress. From 1998 to 2011, blood samples were collected from 1,231 pups captured on 37 rookeries across their Alaskan range. Reference ranges are reported separately for the western and eastern distinct population segments (DPS) of Steller sea lion after cluster analysis and discriminant function analysis (DFA) supported underlying stock structure. Variables with greater loading scores for the DFA (creatinine, total protein, calcium, albumin, cholesterol, and alkaline phosphatase) also were greater for sea lions from the endangered western DPS, supporting previous studies that indicated pup condition in the west was not compromised during the first month postpartum. Differences between population segments were likely a result of ecological, physiological, or age related differences.

  12. Nonparametric spirometry reference values for Hispanic Americans.

    PubMed

    Glenn, Nancy L; Brown, Vanessa M

    2011-02-01

    Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.

  13. Applications of asymptotic confidence intervals with continuity corrections for asymmetric comparisons in noninferiority trials.

    PubMed

    Soulakova, Julia N; Bright, Brianna C

    2013-01-01

    A large-sample problem of illustrating noninferiority of an experimental treatment over a referent treatment for binary outcomes is considered. The methods of illustrating noninferiority involve constructing the lower two-sided confidence bound for the difference between binomial proportions corresponding to the experimental and referent treatments and comparing it with the negative value of the noninferiority margin. The three considered methods, Anbar, Falk-Koch, and Reduced Falk-Koch, handle the comparison in an asymmetric way, that is, only the referent proportion out of the two, experimental and referent, is directly involved in the expression for the variance of the difference between two sample proportions. Five continuity corrections (including zero) are considered with respect to each approach. The key properties of the corresponding methods are evaluated via simulations. First, the uncorrected two-sided confidence intervals can, potentially, have smaller coverage probability than the nominal level even for moderately large sample sizes, for example, 150 per group. Next, the 15 testing methods are discussed in terms of their Type I error rate and power. In the settings with a relatively small referent proportion (about 0.4 or smaller), the Anbar approach with Yates' continuity correction is recommended for balanced designs and the Falk-Koch method with Yates' correction is recommended for unbalanced designs. For relatively moderate (about 0.6) and large (about 0.8 or greater) referent proportion, the uncorrected Reduced Falk-Koch method is recommended, although in this case, all methods tend to be over-conservative. These results are expected to be used in the design stage of a noninferiority study when asymmetric comparisons are envisioned. Copyright © 2013 John Wiley & Sons, Ltd.

  14. A global multicenter study on reference values: 1. Assessment of methods for derivation and comparison of reference intervals.

    PubMed

    Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K

    2017-04-01

    The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  15. EURAMET key comparison no. EURAMET.T-K1: realisations of the ITS-90 from 2.6 K to 24.5561 K, using rhodium-iron resistance thermometers

    NASA Astrophysics Data System (ADS)

    Gaiser, Christof; Fellmuth, Bernd; Steur, Peter; Szmyrka-Grzebyk, Anna; Manuszkiewicz, Henryk; Lipinski, Leszek; Peruzzi, Andrea; Rusby, Richard; Head, David

    2017-01-01

    In the temperature range from 0.65 K to 24.5561 K, the ITS-90 is defined by specified vapour-pressure equations for 3He and 4He and interpolation equations for a constant-volume gas thermometer using 3He or 4He. The definitions are given in sections 3.1 and 3.2 of the ITS-90 text, and methods for realising the scale in this range are outlined in chapters 4 and 5 of the Guide to the Realization of the ITS-90 (formerly Supplementary Information for the ITS-90). Direct realisations of the ITS-90 by these methods require relatively sophisticated apparatus and time-consuming experiments, and consequently they are rarely carried out. The situation is acceptable in practice only because rhodium-iron resistance thermometers (RIRTs) are available that, once calibrated, are able to maintain their calibrations reliably for long periods of time. They are the practical thermometers on which realisations of the ITS-90 are most accurately maintained, disseminated and compared. The key comparison EURAMET.T-K1 is therefore a comparison of calibrated RIRTs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Education: A Guide to Reference and Information Sources. Second Edition. Reference Sources in the Social Sciences Series.

    ERIC Educational Resources Information Center

    O'Brien, Nancy Patricia

    The purpose of this guide is to provide information about the key reference and information resources in the field of education. Sources include items published from 1990 through 1998, with selective inclusion of significant or unique works published prior to 1990. The guide is divided into 14 categories that reflect different aspects of…

  17. Empirical Reference Distributions for Networks of Different Size

    PubMed Central

    Smith, Anna; Calder, Catherine A.; Browning, Christopher R.

    2016-01-01

    Network analysis has become an increasingly prevalent research tool across a vast range of scientific fields. Here, we focus on the particular issue of comparing network statistics, i.e. graph-level measures of network structural features, across multiple networks that differ in size. Although “normalized” versions of some network statistics exist, we demonstrate via simulation why direct comparison is often inappropriate. We consider normalizing network statistics relative to a simple fully parameterized reference distribution and demonstrate via simulation how this is an improvement over direct comparison, but still sometimes problematic. We propose a new adjustment method based on a reference distribution constructed as a mixture model of random graphs which reflect the dependence structure exhibited in the observed networks. We show that using simple Bernoulli models as mixture components in this reference distribution can provide adjusted network statistics that are relatively comparable across different network sizes but still describe interesting features of networks, and that this can be accomplished at relatively low computational expense. Finally, we apply this methodology to a collection of ecological networks derived from the Los Angeles Family and Neighborhood Survey activity location data. PMID:27721556

  18. Improved reference models for middle atmosphere ozone

    NASA Technical Reports Server (NTRS)

    Keating, G. M.; Pitts, M. C.; Chen, C.

    1990-01-01

    This paper describes the improvements introduced into the original version of ozone reference model of Keating and Young (1985, 1987) which is to be incorporated in the next COSPAR International Reference Atmosphere (CIRA). The ozone reference model will provide information on the global ozone distribution (including the ozone vertical structure as a function of month and latitude from 25 to 90 km) combining data from five recent satellite experiments: the Nimbus 7 LIMS, Nimbus 7 SBUV, AE-2 Stratospheric Aerosol Gas Experiment (SAGE), Solar Mesosphere Explorer (SME) UV Spectrometer, and SME 1.27 Micron Airglow. The improved version of the reference model uses reprocessed AE-2 SAGE data (sunset) and extends the use of SAGE data from 1981 to the 1981-1983 time period. Comparisons are presented between the results of this ozone model and various nonsatellite measurements at different levels in the middle atmosphere.

  19. Update of the BIPM comparison BIPM.RI(II)-K1.Cu-64 of activity measurements of the radionuclide 64Cu to include the 2009 results of the CMI-IIR (Czech Rep.) and the NPL (UK), the 2010 result of the LNE-LNHB (France) and the 2011 result of the ENEA-INMRI (Italy)

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Ratel, G.; Courte, S.; Sochorovà, J.; Auerbach, P.; Keightley, J.; Johansson, L.; Bakhshandeiar, E.; Cassette, P.; Moune, M.; Capogni, M.; De Felice, P.

    2013-01-01

    Since 2009, four national metrology institutes (NMI) have submitted four samples of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Cu-64. The values of the activity submitted were between about 3 MBq and 260 MBq. There are now five results in the BIPM.RI(II)-K1.Cu-64 comparison. A key comparison reference value (KCRV) has been calculated for the first time for this nuclide. The degrees of equivalence between each equivalent activity measured in the SIR and the KCRV have been calculated and the results are given in the form of a table. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Reference Value Advisor: a new freeware set of macroinstructions to calculate reference intervals with Microsoft Excel.

    PubMed

    Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine

    2011-03-01

    International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.

  1. USE OF SEDIMENT CORES TO ESTABLISH REFERENCE CONDITIONS

    EPA Science Inventory

    In order to assess the degree to which integrity of waterbodies have been degraded, comparisons are made to "reference" conditions. Finding systems with similar ecological components, but absent the specific stressors of concern, may often be difficult or even impossible. An alt...

  2. The Then and Now of Reference Conditions in Streams of the Central Plains

    NASA Astrophysics Data System (ADS)

    Huggins, D.; Angelo, R.; Baker, D. S.; Welker, G.

    2005-05-01

    Models of contemporary and pre-settlement reference conditions were constructed for streams that once drained the tallgrass prairies of Iowa, Nebraska, Kansas and Missouri (e.g. Western Corn Belt Plains ecoregion), and for streams within the heart of the mixed grass prairie (e.g. Southwestern Tablelands ecoregion). Data on watershed, habitat, chemistry and biology compiled for existing reference streams (least or minimally impacted systems) were used to characterize contemporary reference conditions. Contemporary reference conditions within these two prairie regions are contrasted against hypothetical pre-settlement conditions using information from the best streams (upper 25%) of the current reference population, historical accounts, museum records, natural heritage programs, Public Land Survey and current remote sensing data. Similar comparisons were made between historical and current reference conditions for the Southwestern Tablelands located in central Kansas and Oklahoma. Much of this region remains in mixed grass prairie; has limited hydrological alterations (e.g. impoundments, dewatering) and low human and livestock densities. Within the tablelands these factors have preserved reference conditions that resemble historic conditions. Qualitative and quantitative comparisons indicate that many regions within the Central Plains require caution when using "least disturbed" reference streams and conditions to identify regional biological integrity goals relative to the Clean Water Act.

  3. Final report on EURAMET.QM-S10/1274: supplementary comparison of preparative capabilities for automotive gas mixtures

    NASA Astrophysics Data System (ADS)

    Val'ková, M.; Ďurišová, Z.; Szilágyi, Z. N.; Büki, T.; Fükű, J.

    2016-01-01

    This bilateral supplementary preparative comparison involves standard gas mixtures of automotive gas containing carbon monoxide, carbon dioxide and propane in nitrogen. Two laboratories (SMU, Slovakia and MKEH, Hungary) participated in this supplementary comparison. SMU was the coordinating laboratory, responsible for collecting and reporting measurement results. The participants have established facilities for automotive gas gravimetric preparation and analysis. The agreement of the results in this supplementary comparison is good. All the results with their reported uncertainties are in agreement with the reference values for the participants. SMU participated and obtained good results in the previous preparative comparison organised within EURAMET in this field. Both laboratories have existing claims for their Calibration and Measurement Capabilities (CMCs) for automotive gas mixtures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. An N+3 Technology Level Reference Propulsion System

    NASA Technical Reports Server (NTRS)

    Jones, Scott M.; Haller, William J.; Tong, Michael To-Hing

    2017-01-01

    An N+3 technology level engine, suitable as a propulsion system for an advanced single-aisle transport, was developed as a reference cycle for use in technology assessment and decision-making efforts. This reference engine serves three main purposes: it provides thermodynamic quantities at each major engine station, it provides overall propulsion system performance data for vehicle designers to use in their analyses, and it can be used for comparison against other proposed N+3 technology-level propulsion systems on an equal basis. This reference cycle is meant to represent the expected capability of gas turbine engines in the N+3 timeframe given reasonable extrapolations of technology improvements and the ability to take full advantage of those improvements.

  5. A statistically robust EEG re-referencing procedure to mitigate reference effect

    PubMed Central

    Lepage, Kyle Q.; Kramer, Mark A.; Chu, Catherine J.

    2014-01-01

    Background The electroencephalogram (EEG) remains the primary tool for diagnosis of abnormal brain activity in clinical neurology and for in vivo recordings of human neurophysiology in neuroscience research. In EEG data acquisition, voltage is measured at positions on the scalp with respect to a reference electrode. When this reference electrode responds to electrical activity or artifact all electrodes are affected. Successful analysis of EEG data often involves re-referencing procedures that modify the recorded traces and seek to minimize the impact of reference electrode activity upon functions of the original EEG recordings. New method We provide a novel, statistically robust procedure that adapts a robust maximum-likelihood type estimator to the problem of reference estimation, reduces the influence of neural activity from the re-referencing operation, and maintains good performance in a wide variety of empirical scenarios. Results The performance of the proposed and existing re-referencing procedures are validated in simulation and with examples of EEG recordings. To facilitate this comparison, channel-to-channel correlations are investigated theoretically and in simulation. Comparison with existing methods The proposed procedure avoids using data contaminated by neural signal and remains unbiased in recording scenarios where physical references, the common average reference (CAR) and the reference estimation standardization technique (REST) are not optimal. Conclusion The proposed procedure is simple, fast, and avoids the potential for substantial bias when analyzing low-density EEG data. PMID:24975291

  6. Rebreathed air as a reference for breath-alcohol testers

    DOT National Transportation Integrated Search

    1975-01-01

    A technique has been devised for a reference measurement of the performance of breath-alcohol measuring instruments directly from the respiratory system. It is shown that this technique is superior and simpler than comparison measurements based on bl...

  7. Force supplementary comparison at SIM (SIM.M.F-S5), compression testing machines calibration, up to 200 kN

    NASA Astrophysics Data System (ADS)

    Cárdenas Moctezuma, A.; Torres Guzmán, J. C.

    2016-01-01

    CENAM, through the Force and Pressure Division, organized a comparison on testing machines calibration, in compression mode. The participating laboratories were SIM National Institutes of Metrology from Colombia, Peru and Costa Rica, where CENAM, Mexico was the pilot and reference laboratory. The results obtained by the laboratories are presented in this paper as well as the analysis of compatibility. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. 6. September 1971 DETAIL VIEW OF CHAIN PADLOCK AND KEY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. September 1971 DETAIL VIEW OF CHAIN PADLOCK AND KEY TO SECURE DOOR TO MAIN CELL BLOCK, NOTE STANDARD MODERN PADLOCK FOR SIZE COMPARISON - Jefferson County Jail & Sheriff's Office, Courthouse Square, Madison, Jefferson County, IN

  9. Comparison of two reference methods for detemining cotton fiber moisture

    USDA-ARS?s Scientific Manuscript database

    Moisture is an important quality and processing property for the cotton industry. The standard reference method for determining the moisture content in cotton fiber is the ASTM oven method (gravimetric weight loss). Several concerns have expressed on its ability to measure the actual moisture cont...

  10. Challenges in the size analysis of a silica nanoparticle mixture as candidate certified reference material

    NASA Astrophysics Data System (ADS)

    Kestens, Vikram; Roebben, Gert; Herrmann, Jan; Jämting, Åsa; Coleman, Victoria; Minelli, Caterina; Clifford, Charles; De Temmerman, Pieter-Jan; Mast, Jan; Junjie, Liu; Babick, Frank; Cölfen, Helmut; Emons, Hendrik

    2016-06-01

    A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission's Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.

  11. EURAMET.M.P-S9 / EURAMET 1170, LOOP2. Comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Otal, P.; Boineau, F.; Medina, N.; Pražák, D.; Wüthrich, C.; Saxholm, S.; Sabuga, W.; Kocas, I.; Durgut, Y.

    2017-01-01

    This report gives the results of a comparison of pressure standards of seven European National Metrology institutes in the range of negative gauge pressure from -950 hPa to 0 hPa. This comparison was piloted by LNE and was carried out from January 2011 to March 2012. This work is a part of the EURAMET project 1170 and is registered as a supplementary comparison EURAMET.M.P-S9. The transfer standard used was a pressure monitor RPM4 A160Ks manufactured by DH Instruments Inc., with a resolution of 0.1 Pa. The reference values have been determined from the weighted mean of the deviations reported by the participants for each specified pressure. Seventy-three of the seventy-seven values (96%) reported by the laboratories agree with the reference values within the expanded uncertainties with a coverage factor k = 2. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Theory and Realization of Global Terrestrial Reference Systems

    NASA Technical Reports Server (NTRS)

    Ma, C.; Bolotin, S.; Gipson, J.; Gordon, D.; Le Bail, K.; MacMillan, D.

    2010-01-01

    Comparison of realizations of the terrestrial reference frame. IGN and DGFI both generated realizations of the terrestrial reference frame under the auspices of the IERS from combination of the same space geodetic data. We examined both results for VLBI sites using the full geodetic VLBI data set with respect to site positions and velocities and time series of station positions, baselines and Earth orientation parameters. One of the difficulties encountered was matching episodic breaks and periods of non-linear motion of the two realizations with the VLBI models. Our analysis and conclusions will be discussed.

  13. Comparison of Realizations of the Terrestrial Reference Frame

    NASA Technical Reports Server (NTRS)

    Ma, C.; Macmillan, D.; Bolotin, S.; Le Bail, K.; Gordon, D.; Gipson, J.

    2015-01-01

    IGN and DGFI both generated realizations of the terrestrial reference frame under the auspices of the IERS from combination of the same space geodetic data. We compared the IGN and DGFI TRFs with a GSFC CALC/SOLVE TRF. WRMS position and velocity differences for the 40 most frequently observed sites were 2-3 mm and 0.3-0.4 mm/year. There was a scale difference of 0.39/0.09 ppb between the IGN/DGFI realizations and the GSFC solution. When we fixed positions and velocities to either the IGN or DGFI values in CALC/SOLVE solutions, the resulting EOP estimates were not significantly different from the estimates from a standard TRF solution.

  14. Generic Argillite/Shale Disposal Reference Case

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Liange; Colon, Carlos Jové; Bianchi, Marco

    properties (parameters) used in these models are different, which not only make inter-model comparisons difficult, but also compromise the applicability of the lessons learned from one model to another model. The establishment of a reference case would therefore be helpful to set up a baseline for model development. A generic salt repository reference case was developed in Freeze et al. (2013) and the generic argillite repository reference case is presented in this report. The definition of a reference case requires the characterization of the waste inventory, waste form, waste package, repository layout, EBS backfill, host rock, and biosphere. This report mainly documents the processes in EBS bentonite and host rock that are potentially important for performance assessment and properties that are needed to describe these processes, with brief description other components such as waste inventory, waste form, waste package, repository layout, aquifer, and biosphere. A thorough description of the generic argillite repository reference case will be given in Jové Colon et al. (2014).« less

  15. Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the VSL, Netherlands and the BIPM in accelerator photon beams

    NASA Astrophysics Data System (ADS)

    Picard, S.; Burns, D. T.; Roger, P.; de Prez, L. A.; Jansen, B. J.; Pooter, J. A.

    2017-01-01

    A comparison of the dosimetry for accelerator photon beams was carried out between the Dutch Metrology Institute (VSL) and the Bureau International des Poids et Mesures (BIPM) from 23 September to 20 October 2014. The comparison was based on the determination of absorbed dose to water for three radiation qualities of the medical accelerator facilities of the National Physical Laboratory (United Kingdom). After establishing Draft B, the VSL discovered an error in the calculation of the correction factor for excess-heat linked to the VSL glass vessel used in the measurements at the NPL. The comparison results for the revised standard, reported as ratios of the VSL and the BIPM evaluations (and with the combined standard uncertainties given in parentheses), are 0.9959 (54) at 6 MV, 0.9958 (64) at 10 MV and 0.9991 (75) at 25 MV. This result is part of the on-going BIPM.RI(I)-K6 series of comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. The Web as a Reference Tool: Comparisons with Traditional Sources.

    ERIC Educational Resources Information Center

    Janes, Joseph; McClure, Charles R.

    1999-01-01

    This preliminary study suggests that the same level of timeliness and accuracy can be obtained for answers to reference questions using resources in freely available World Wide Web sites as with traditional print-based resources. Discusses implications for library collection development, new models of consortia, training needs, and costing and…

  17. Bilateral Comparison Between NIM and NMC Over the Temperature Range from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Sun, Jianping; Ye, Shaochun; Kho, Haoyuan; Zhang, Jintao; Wang, Li

    2015-08-01

    A bilateral comparison of local realization of the International Temperature Scale of 1990 between the National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from 83.8058 K to 692.677 K. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin, and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key Comparison 3 (CCT-K3) and facilitate the NMC's calibration and measurement capabilities submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme in 2009, and registered in the Key Comparison Database in 2010 as CCT-K3.2. NMC supplied two fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn, and Zn fixed points, while the other one was used at the Ar and Hg fixed points. NMC measured them before and after NIM measured them. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 average reference value using NIM as a link are reported with expanded uncertainties at each measured fixed point.

  18. Biosimilars: Key regulatory considerations and similarity assessment tools

    PubMed Central

    Wang, Xiao‐Zhuo Michelle; Conlon, Hugh D.; Anderson, Scott; Ryan, Anne M.; Bose, Arindam

    2017-01-01

    Abstract A biosimilar drug is defined in the US Food and Drug Administration (FDA) guidance document as a biopharmaceutical that is highly similar to an already licensed biologic product (referred to as the reference product) notwithstanding minor differences in clinically inactive components and for which there are no clinically meaningful differences in purity, potency, and safety between the two products. The development of biosimilars is a challenging, multistep process. Typically, the assessment of similarity involves comprehensive structural and functional characterization throughout the development of the biosimilar in an iterative manner and, if required by the local regulatory authority, an in vivo nonclinical evaluation, all conducted with direct comparison to the reference product. In addition, comparative clinical pharmacology studies are conducted with the reference product. The approval of biosimilars is highly regulated although varied across the globe in terms of nomenclature and the precise criteria for demonstrating similarity. Despite varied regulatory requirements, differences between the proposed biosimilar and the reference product must be supported by strong scientific evidence that these differences are not clinically meaningful. This review discusses the challenges faced by pharmaceutical companies in the development of biosimilars. PMID:28842986

  19. Key paediatric messages from Amsterdam

    PubMed Central

    Barben, Jürg; Bohlin, Kajsa; Everard, Mark L.; Hall, Graham; Pijnenburg, Mariëlle; Priftis, Kostas N.; Rusconi, Franca; Midulla, Fabio

    2016-01-01

    The Paediatric Assembly of the European Respiratory Society (ERS) maintained its high profile at the 2015 ERS International Congress in Amsterdam. There were symposia on preschool wheeze, respiratory sounds and cystic fibrosis; an educational skills workshop on paediatric respiratory resuscitation; a hot topic session on risk factors and early origins of respiratory diseases; a meet the expert session on paediatric lung function test reference values; and the annual paediatric grand round. In this report the Chairs of the Paediatric Assembly's Groups highlight the key messages from the abstracts presented at the Congress. PMID:27730186

  20. Serials Information on CD-ROM: A Reference Perspective.

    ERIC Educational Resources Information Center

    Karch, Linda S.

    1990-01-01

    Describes Ulrich's PLUS (a CD-ROM version of Ulrich's serials directories) and EBSCO's CD-ROM version of "The Serials Directory," and compares the two in terms of their use as reference tools. Areas discussed include database content, user aids, system features, search features, and a comparison of search results. Equipment requirements…

  1. Final report of the key comparison CCQM-K98: Pb isotope amount ratios in bronze

    NASA Astrophysics Data System (ADS)

    Vogl, Jochen; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Goenaga-Infante, Heidi; Malinowskiy, Dmitriy; Ren, Tongxiang; Wang, Jun; Vocke, Robert D., Jr.; Murphy, Karen; Nonose, Naoko; Rienitz, Olaf; Noordmann, Janine; Näykki, Teemu; Sara-Aho, Timo; Ari, Betül; Cankur, Oktay

    2014-01-01

    Isotope amount ratios are proving useful in an ever increasing array of applications that range from studies unravelling transport processes, to pinpointing the provenance of specific samples as well as trace element quantification by using isotope dilution mass spectrometry (IDMS). These expanding applications encompass fields as diverse as archaeology, food chemistry, forensic science, geochemistry, medicine and metrology. However, to be effective tools, the isotope ratio data must be reliable and traceable to enable the comparability of measurement results. The importance of traceability and comparability in isotope ratio analysis has already been recognized by the Inorganic Analysis Working Group (IAWG) within the CCQM. While the requirements for isotope ratio accuracy and precision in the case of IDMS are generally quite modest, 'absolute' Pb isotope ratio measurements for geochemical applications as well as forensic provenance studies require Pb isotope ratio measurements of the highest quality. To support present and future CMCs on isotope ratio determinations, a key comparison was urgently needed and therefore initiated at the IAWG meeting in Paris in April 2011. The analytical task within such a comparison was decided to be the measurement of Pb isotope amount ratios in water and bronze. Measuring Pb isotope amount ratios in an aqueous Pb solution tested the ability of analysts to correct for any instrumental effects on the measured ratios, while the measurement of Pb isotope amount ratios in a metal matrix sample provided a real world test of the whole chemical and instrumental procedure. A suitable bronze material with a Pb mass fraction between 10 and 100 mg•kg-1 and a high purity solution of Pb with a mass fraction of approximately 100 mg•kg-1 was available at the pilot laboratory (BAM), both offering a natural-like Pb isotopic composition. The mandatory measurands, the isotope amount ratios n(206Pb)/n(204Pb), n(207Pb)/n(204Pb) and n(208Pb)/n(204Pb

  2. "State of the Nation": A Discussion of Some of the Project's Key Findings

    ERIC Educational Resources Information Center

    Earley, Peter

    2010-01-01

    This paper considers several of the key findings of the State of the Nation research. Specific reference is made to three areas--impact evaluation, strategic leadership of professional development, and barriers and constraints to effective CPD practice--which are considered with reference to findings from the other TDA-funded projects conducted at…

  3. A first comparison of the responses of a 4He-based fast-neutron detector and a NE-213 liquid-scintillator reference detector

    NASA Astrophysics Data System (ADS)

    Jebali, R.; Scherzinger, J.; Annand, J. R. M.; Chandra, R.; Davatz, G.; Fissum, K. G.; Friederich, H.; Gendotti, U.; Hall-Wilton, R.; Håkansson, E.; Kanaki, K.; Lundin, M.; Murer, D.; Nilsson, B.; Rosborg, A.; Svensson, H.

    2015-09-01

    A first comparison has been made between the pulse-shape discrimination characteristics of a novel 4He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquid-scintillator reference cell produced a wide range of scintillation-light yields in response to the gamma-ray field of the source. In stark contrast, due to the size and pressure of the 4He gas volume, the 4He-based detector registered a maximum scintillation-light yield of 750keVee to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750keVee was excellent in the case of the 4He-based detector. Above 750keVee its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced.

  4. S1 certification of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in a candidate certified reference material (organochlorine pesticides in tea) by isotope dilution gas chromatography-mass spectrometry.

    PubMed

    Sin, Della Wai-Mei; Wong, Yee-Lok; Cheng, Eddie Chung-Chin; Lo, Man-Fung; Ho, Clare; Mok, Chuen-Shing; Wong, Siu-Kay

    2015-04-01

    This paper presents the certification of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in a candidate tea certified reference material (code: GLHK-11-03) according to the requirements of the ISO Guide 30 series. Certification of GLHK-11-03 was based on an analytical method purposely developed for the accurate measurement of the mass fraction of the target analytes in the material. An isotope dilution mass spectrometry (IDMS) method involving determination by (i) gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS) and (ii) gas chromatography-electron ionization-high-resolution mass spectrometry (GC-EI-HRMS) techniques was employed. The performance of the described method was demonstrated through participation in the key comparison CCQM-K95 "Mid-Polarity Analytes in Food Matrix: Mid-Polarity Pesticides in Tea" organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry in 2012, where the study material was the same as the certified reference material (CRM). The values reported by using the developed method were in good agreement with the key comparison reference value (KCRV) assigned for beta-endosulfan (727 ± 14 μg kg(-1)) and endosulfan sulfate (505 ± 11 μg kg(-1)), where the degree of equivalence (DoE) values were 0.41 and 0.40, respectively. The certified values of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in dry mass fraction in GLHK-11-03 were 350, 730, and 502 μg kg(-1), respectively, and the respective expanded uncertainties, due to sample inhomogeneity, long-term and short-term stability, and variability in the characterization procedure, were 27 μg kg(-1) (7.8 %), 48 μg kg(-1) (6.6 %), and 33 μg kg(-1) (6.6 %).

  5. Reference Charts for Height and Weight of School Children from West Malaysia in Comparison with the United States Centers for Disease Control and Prevention

    PubMed Central

    Bong, YB; Shariff, AA; Majid, AM; Merican, AF

    2012-01-01

    Background: Reference charts are widely used in healthcare as a screening tool. This study aimed to produce reference growth charts for school children from West Malaysia in comparison with the United States Centers for Disease Control and Prevention (CDC) chart. Methods: A total of 14,360 school children ranging from 7 to 17 years old from six states in West Malaysia were collected. A two-stage stratified random sampling technique was used to recruit the subjects. Curves were adjusted using Cole’s LMS method. The LOWESS method was used to smooth the data. Results: The means and standard deviations for height and weight for both genders are presented. The results showed good agreement with growth patterns in other countries, i.e., males tend to be taller and heavier than females for most age groups. Height and weight of females reached a plateau at 17 years of age; however, males were still growing at this age. The growth charts for West Malaysian school children were compared with the CDC 2000 growth charts for school children in the United States. Conclusion: The height and weight for males and females at the start of school-going ages were almost similar. The comparison between the growth charts from this study and the CDC 2000 growth charts indicated that the growth patterns of West Malaysian school children have improved, although the height and weight of American school children were higher than those for West Malaysian school children. PMID:23113132

  6. Evaluation of the MyWellness Key accelerometer.

    PubMed

    Herrmann, S D; Hart, T L; Lee, C D; Ainsworth, B E

    2011-02-01

    to examine the concurrent validity of the Technogym MyWellness Key accelerometer against objective and subjective physical activity (PA) measures. randomised, cross-sectional design with two phases. The laboratory phase compared the MyWellness Key with the ActiGraph GT1M and the Yamax SW200 Digiwalker pedometer during graded treadmill walking, increasing speed each minute. The free-living phase compared the MyWellness Key with the ActiGraph, Digiwalker, Bouchard Activity cord (BAR) and Global Physical Activity Questionnaire (GPAQ) for seven continuous days. Data were analysed using Spearman rank-order correlation coefficients for all comparisons. laboratory and free-living phases. sixteen participants randomly stratified from 41 eligible respondents by sex (n=8 men; n=8 women) and PA levels (n=4 low, n=8 middle and n=4 high active). there was a strong association between the MyWellness Key and the ActiGraph accelerometer during controlled graded treadmill walking (r=0.91, p<0.01) and in free-living settings (r=0.73-0.76 for light to vigorous PA, respectively, p<0.01). No associations were observed between the MyWellness Key and the BAR and GPAQ (p>0.05). the MyWellness Key has a high concurrent validity with the ActiGraph accelerometer to detect PA in both controlled laboratory and free-living settings.

  7. Association of Reference Pricing with Drug Selection and Spending

    PubMed Central

    Robinson, James C.; Whaley, Christopher M.; Brown, Timothy T.

    2017-01-01

    BACKGROUND In the United States, prices for therapeutically similar drugs vary widely, which has prompted efforts by public and private insurers to steer patients toward the lower-priced options. Under reference pricing, the insurer or employer establishes a maximum contribution it will make toward the price of a drug or procedure, and the patient pays the remainder. METHODS We used difference-in-differences multivariable regression methods to analyze changes in prescriptions and pricing for 1302 drugs in 78 therapeutic classes in the United States, before and after implementation of reference pricing by an alliance of private employers. We assessed trends for the study group relative to those for an employee group that was not subject to reference pricing. The study included 1,122,741 prescriptions that were reimbursed during the period from 2010 through 2014. RESULTS Implementation of reference pricing was associated with a higher percentage of prescriptions that were filled for the lowest-priced reference drug within its therapeutic class (difference in probability, 7.0 percentage points; 95% confidence interval [CI], 4.0 to 9.9), a lower average price paid per prescription (−13.9%; 95% CI, −23.8 to −2.7), and a higher rate of copayment by patients (5.2%; 95% CI, 0.2 to 10.4) than in the comparison group. During the first 18 months after implementation, spending for employers was $1.34 million lower and the amount of copayments for employees was $0.12 million higher than in the comparison group. CONCLUSIONS Implementation of reference pricing was associated with significant changes in drug selection and spending for a population of patients covered by employment-based insurance in the United States. (Funded by the Agency for Healthcare Research and Quality and the Genentech Foundation.) PMID:28813219

  8. Memory systems interaction in the pigeon: working and reference memory.

    PubMed

    Roberts, William A; Strang, Caroline; Macpherson, Krista

    2015-04-01

    Pigeons' performance on a working memory task, symbolic delayed matching-to-sample, was used to examine the interaction between working memory and reference memory. Reference memory was established by training pigeons to discriminate between the comparison cues used in delayed matching as S+ and S- stimuli. Delayed matching retention tests then measured accuracy when working and reference memory were congruent and incongruent. In 4 experiments, it was shown that the interaction between working and reference memory is reciprocal: Strengthening either type of memory leads to a decrease in the influence of the other type of memory. A process dissociation procedure analysis of the data from Experiment 4 showed independence of working and reference memory, and a model of working memory and reference memory interaction was shown to predict the findings reported in the 4 experiments. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  9. Comparison of density determination of liquid samples by density meters

    NASA Astrophysics Data System (ADS)

    Buchner, C.; Wolf, H.; Vámossy, C.; Lorefice, S.; Lenard, E.; Spohr, I.; Mares, G.; Perkin, M.; Parlic-Risovic, T.; Grue, L.-L.; Tammik, K.; van Andel, I.; Zelenka, Z.

    2016-01-01

    Hydrostatic density determinations of liquids as reference material are mainly performed by National Metrology Institutes to provide means for calibrating or checking liquid density measuring instruments such as oscillation-type density meters. These density meters are used by most of the metrology institutes for their calibration and scientific work. The aim of this project was to compare the results of the liquid density determination by oscillating density meters of the participating laboratories. The results were linked to CCM.D.K-2 partly via Project EURAMET.M.D.K-2 (1019) "Comparison of liquid density standards" by hydrostatic weighing piloted by BEV in 2008. In this comparison pentadecane, water and of oil with a high viscosity were measured at atmospheric pressure using oscillation type density meter. The temperature range was from 15 °C to 40 °C. The measurement results were in some cases discrepant. Further studies, comparisons are essential to explore the capability and uncertainty of the density meters Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Ecological Understanding 2: Transformation--A Key to Ecological Understanding.

    ERIC Educational Resources Information Center

    Carlsson, Britta

    2002-01-01

    Describes the structure and general features of the phenomenon of ecological understanding. Presents qualitatively different ways of experiencing cycling of matter and the flow of energy in the context of ecosystems. The idea of transformation is key to the development of ecological understanding. (Contains 17 references.) (Author/YDS)

  11. Trace element reference values in tissues from inhabitants of the EU. XII. Development of BioReVa program for statistical treatment.

    PubMed

    Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A

    2003-01-20

    Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan

  12. A Comparative Study of Standardized Infinity Reference and Average Reference for EEG of Three Typical Brain States

    PubMed Central

    Zheng, Gaoxing; Qi, Xiaoying; Li, Yuzhu; Zhang, Wei; Yu, Yuguo

    2018-01-01

    The choice of different reference electrodes plays an important role in deciphering the functional meaning of electroencephalography (EEG) signals. In recent years, the infinity zero reference using the reference electrode standard technique (REST) has been increasingly applied, while the average reference (AR) was generally advocated as the best available reference option in previous classical EEG studies. Here, we designed EEG experiments and performed a direct comparison between the influences of REST and AR on EEG-revealed brain activity features for three typical brain behavior states (eyes-closed, eyes-open and music-listening). The analysis results revealed the following observations: (1) there is no significant difference in the alpha-wave-blocking effect during the eyes-open state compared with the eyes-closed state for both REST and AR references; (2) there was clear frontal EEG asymmetry during the resting state, and the degree of lateralization under REST was higher than that under AR; (3) the global brain functional connectivity density (FCD) and local FCD have higher values for REST than for AR under different behavior states; and (4) the value of the small-world network characteristic in the eyes-closed state is significantly (in full, alpha, beta and gamma frequency bands) higher than that in the eyes-open state, and the small-world effect under the REST reference is higher than that under AR. In addition, the music-listening state has a higher small-world network effect than the eyes-closed state. The above results suggest that typical EEG features might be more clearly presented by applying the REST reference than by applying AR when using a 64-channel recording. PMID:29593490

  13. Reference Model for Performance Management in Service-Oriented Virtual Organization Breeding Environments

    NASA Astrophysics Data System (ADS)

    Paszkiewicz, Zbigniew; Picard, Willy

    Performance management (PM) is a key function of virtual organization (VO) management. A large set of PM indicators has been proposed and evaluated within the context of virtual breeding environments (VBEs). However, it is currently difficult to describe and select suitable PM indicators because of the lack of a common vocabulary and taxonomies of PM indicators. Therefore, there is a need for a framework unifying concepts in the domain of VO PM. In this paper, a reference model for VO PM is presented in the context of service-oriented VBEs. In the proposed reference model, both a set of terms that could be used to describe key performance indicators, and a set of taxonomies reflecting various aspects of PM are proposed. The proposed reference model is a first attempt and a work in progress that should not be supposed exhaustive.

  14. The Neurobiology of Reference-Dependent Value Computation

    PubMed Central

    De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.

    2009-01-01

    A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780

  15. A height-for-age growth reference for children with achondroplasia: Expanded applications and comparison with original reference data.

    PubMed

    Hoover-Fong, Julie; McGready, John; Schulze, Kerry; Alade, Adekemi Yewande; Scott, Charles I

    2017-05-01

    The height-for-age (HA) reference currently used for children with achondroplasia is not adaptable for electronic records or calculation of HA Z-scores. We report new HA curves and tables of mean and standard deviation (SD) HA, for calculating Z-scores, from birth-16 years in achondroplasia. Mixed longitudinal data were abstracted from medical records of achondroplasia patients from a single clinical practice (CIS, 1967-2004). Gender-specific height percentiles (5, 25, 50, 75, 95th) were estimated across the age continuum, using a 2 month window per time point smoothed by a quadratic smoothing algorithm. HA curves were constructed for 0-36 months and 2-16 years to optimize resolution for younger children. Mean monthly height (SD) was tabulated. These novel HA curves were compared to reference data currently in use for children with achondroplasia. 293 subjects (162 male/131 female) contributed 1,005 and 932 height measures, with greater data paucity with age. Mean HA tracked with original achondroplasia norms, particularly through mid-childhood (2-9 years), but with no evidence of a pubertal growth spurt. Standard deviation of height at each month interval increased from birth through 16 years. Birth length was lower in achondroplasia than average stature and, as expected, height deficits increased with age. A new HA reference is available for longitudinal growth assessment in achondroplasia, taking advantage of statistical modeling techniques and allowing for Z-score calculations. This is an important contribution to clinical care and research endeavors for the achondroplasia population. © 2017 Wiley Periodicals, Inc.

  16. Certified reference materials and reference methods for nuclear safeguards and security.

    PubMed

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and

  17. Canine and feline hematology reference values for the ADVIA 120 hematology system.

    PubMed

    Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J

    2004-01-01

    The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.

  18. Dietary intake of macro- and micronutrients in Slovenian adolescents: comparison with reference values.

    PubMed

    Fidler Mis, Nataša; Kobe, Helena; Stimec, Matevž

    2012-01-01

    Data on a nationally representative dietary intake in Central Europe is lacking. We investigated the diet of adolescents in Slovenia. Dietary habits were assessed using a food frequency questionnaire (n = 2,661), and present nutrition was assessed using a 3-day weighted dietary protocol (n = 197) for validation purposes. Dietary intake was calculated and compared with Central European [German (D), Austrian (A), and Swiss (CH); D-A-CH] recommendations and World Health Organization/Food and Agriculture Organization (WHO/FAO) recommendations. Adolescents consumed exceeding reference intake values of free sugars (boys 16% of energy, girls 17%), saturated fatty acids (SFA; 13% of energy), and sodium (boys 203%, girls 210% of the WHO/FAO upper limit), but below-reference intake values of polyunsaturated fatty acids (PUFA; boys 5% of energy; girls 6%), water (boys 1,786 ml/day, girls 2,016 ml/day), and fiber density (only girls 2.8 g/MJ, p < 0.001). Among micronutrients, below-reference intakes (% of D-A-CH: boys and girls, respectively, p < 0.05) were reported for folate (64 and 69%), fluoride (28 and 31%), and calcium (91 and 97%), as well as for vitamin D (20 and 20%). The dietary habits of Slovenian adolescents are less than optimal. They are characterized by exceeding reference intake values of free sugars, salt, and SFA, and a below-reference intake of PUFA, water, and several micronutrients. Copyright © 2012 S. Karger AG, Basel.

  19. Data key to quest for quality.

    PubMed

    Chang, Florence S; Nielsen, Jon; Macias, Charles

    2013-11-01

    Late-binding data warehousing reduces the time it takes to obtain data needed to make crucial decisions. Late binding refers to when and how tightly data from the source applications are bound to the rules and vocabularies that make it useful. In some cases, data can be seen in real time. In historically paper-driven environments where data-driven decisions may be a new concept, buy-in from clinicians, physicians, and hospital leaders is key to success in using data to improve outcomes.

  20. An overview of key silvicultural information for ponderosa pine

    Treesearch

    John Fiske; John Tappeiner

    2005-01-01

    This paper provides a selected list of classical references for the important silvicultural findings for ponderosa pine, and categorizes some of the key current literature, as well as some of the older, lesser known but important literature. The paper also provides some history of scientific developments, and sources of further information.

  1. Social Comparison Processes in Organizations

    ERIC Educational Resources Information Center

    Greenberg, Jerald; Ashton-James, Claire E.; Ashkanasy, Neal M.

    2007-01-01

    We systematically analyze the role of social comparison processes in organizations. Specifically, we describe how social comparison processes have been used to explain six key areas of organizational inquiry: (1) organizational justice, (2) performance appraisal, (3) virtual work environments, (4) affective behavior in the workplace, (5) stress,…

  2. USING REGIONAL EXPOSURE CRITERIA AND UPSTREAM REFERENCE DATA TO CHARACTERIZE SPATIAL AND TEMPORAL EXPOSURES TO CHEMICAL CONTAMINANTS

    EPA Science Inventory

    Analyses of biomarkers in fish were used to evaluate exposures among locations and across time. Two types of references were used for comparison, an upstream reference sample remote from known point sources and regional exposure criteria derived from a baseline of fish from refer...

  3. USING REGIONAL EXPOSURE CRITERIA AND UPSTREAM REFERENCE DATA TO CHARACTERIZE SPATIAL AND TEMPORAL EXPOSURES TO CHEMICAL CONTAMINANTS

    EPA Science Inventory

    Analyses of biomarkers in fish were used to evaluate exposures among locations and across time. Two types of references were used for comparison, an upstream reference sample remote from known point sources and regional exposure criteria derived from a basline of fish from refere...

  4. Criminal Investigation of Child Sexual Abuse: A Comparison of Cases Referred to the Prosecutor to Those Not Referred.

    ERIC Educational Resources Information Center

    Stroud, Delores D.; Martens, Sonja L.; Barker, Julia

    2000-01-01

    This study compared characteristics of child sexual abuse cases either referred for criminal prosecution (N=587) or dropped (N=456) by investigators. Differences were found between groups in relation to child characteristics (age, sex, and ethnicity), offender characteristics (age, sex, and relationship to child), and case characteristics…

  5. The development of an automatic recognition system for earmark and earprint comparisons.

    PubMed

    Junod, Stéphane; Pasquier, Julien; Champod, Christophe

    2012-10-10

    The value of earmarks as an efficient means of personal identification is still subject to debate. It has been argued that the field is lacking a firm systematic and structured data basis to help practitioners to form their conclusions. Typically, there is a paucity of research guiding as to the selectivity of the features used in the comparison process between an earmark and reference earprints taken from an individual. This study proposes a system for the automatic comparison of earprints and earmarks, operating without any manual extraction of key-points or manual annotations. For each donor, a model is created using multiple reference prints, hence capturing the donor within source variability. For each comparison between a mark and a model, images are automatically aligned and a proximity score, based on a normalized 2D correlation coefficient, is calculated. Appropriate use of this score allows deriving a likelihood ratio that can be explored under known state of affairs (both in cases where it is known that the mark has been left by the donor that gave the model and conversely in cases when it is established that the mark originates from a different source). To assess the system performance, a first dataset containing 1229 donors elaborated during the FearID research project was used. Based on these data, for mark-to-print comparisons, the system performed with an equal error rate (EER) of 2.3% and about 88% of marks are found in the first 3 positions of a hitlist. When performing print-to-print transactions, results show an equal error rate of 0.5%. The system was then tested using real-case data obtained from police forces. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. A structural SVM approach for reference parsing.

    PubMed

    Zhang, Xiaoli; Zou, Jie; Le, Daniel X; Thoma, George R

    2011-06-09

    Automated extraction of bibliographic data, such as article titles, author names, abstracts, and references is essential to the affordable creation of large citation databases. References, typically appearing at the end of journal articles, can also provide valuable information for extracting other bibliographic data. Therefore, parsing individual reference to extract author, title, journal, year, etc. is sometimes a necessary preprocessing step in building citation-indexing systems. The regular structure in references enables us to consider reference parsing a sequence learning problem and to study structural Support Vector Machine (structural SVM), a newly developed structured learning algorithm on parsing references. In this study, we implemented structural SVM and used two types of contextual features to compare structural SVM with conventional SVM. Both methods achieve above 98% token classification accuracy and above 95% overall chunk-level accuracy for reference parsing. We also compared SVM and structural SVM to Conditional Random Field (CRF). The experimental results show that structural SVM and CRF achieve similar accuracies at token- and chunk-levels. When only basic observation features are used for each token, structural SVM achieves higher performance compared to SVM since it utilizes the contextual label features. However, when the contextual observation features from neighboring tokens are combined, SVM performance improves greatly, and is close to that of structural SVM after adding the second order contextual observation features. The comparison of these two methods with CRF using the same set of binary features show that both structural SVM and CRF perform better than SVM, indicating their stronger sequence learning ability in reference parsing.

  7. Problems in archaeomagnetic reference curves elaboration in the prehistoric past.

    NASA Astrophysics Data System (ADS)

    Avramova, M.; Kovacheva, M.; Boyadziev, Y.

    2012-04-01

    dated (perennial or annual) and cultural features. An example for such reference profile is the multilevel site Yunatzite from the Early Bronze Age. The comparison of archaeomagnetic profile Yunatzite with another archaeomagnetically studied Early Bronze Age multilevel site Djadovo shows very good agreement. Comparisons of other archaeomagnetic profiles available for Bulgaria related to the same epoch or sub-epoch will be presented. The expected correspondence can help the refinement of chronology of sites having only stratigraphic profiles. In our opinion the observed discrepancies between the local PSVCs for a given geographical region might be due mainly to the above described difficulties for elaboration of these curves in the prehistory. The further refinement and updating of existing archaeomagnetic databases will help considerably the elaboration of the newest geomagnetic field models. Acknowledgement: A partial financial support is from the Project "The archaeomagnetism - a key for solving fundamental problems in geophysics and archaeology", granted from the Bulgarian National Science Fund.

  8. Teaching about Asia: Professional Materials and Reference Books.

    ERIC Educational Resources Information Center

    Hantula, James N.

    This two-part document serves as a guide to basic materials on Asia. The first part provides the teacher of Asian studies with nonserial examples of pertinent professional materials and reference books in print since 1979. Criteria used in selecting the items are given and a brief comparison between materials available in 1969 and 1985 is made.…

  9. Neurodevelopmental Problems in Maltreated Children Referred with Indiscriminate Friendliness

    ERIC Educational Resources Information Center

    Kocovska, Eva; Puckering, Christine; Follan, Michael; Smillie, Maureen; Gorski, Charlotta; Barnes, James; Wilson, Philip; Young, David; Lidstone, Emma; Pritchett, Rachel; Hockaday, Harriet; Minnis, Helen

    2012-01-01

    We aimed to explore the extent of neurodevelopmental difficulties in severely maltreated adopted children. We recruited 34 adopted children, referred with symptoms of indiscriminate friendliness and a history of severe maltreatment in their early childhood and 32 typically developing comparison children without such a history, living in biological…

  10. Human Exploration of Mars Design Reference Architecture 5.0

    NASA Technical Reports Server (NTRS)

    Drake, Bret G.

    2010-01-01

    This paper provides a summary of the Mars Design Reference Architecture 5.0 (DRA 5.0), which is the latest in a series of NASA Mars reference missions. It provides a vision of one potential approach to human Mars exploration. The reference architecture provides a common framework for future planning of systems concepts, technology development, and operational testing as well as Mars robotic missions, research that is conducted on the International Space Station, and future lunar exploration missions. This summary the Mars DRA 5.0 provides an overview of the overall mission approach, surface strategy and exploration goals, as well as the key systems and challenges for the first three human missions to Mars.

  11. Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays.

    PubMed

    O'Brien, Michelle; Bueermann, Ludwig

    2009-01-01

    A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two NIST reference-class transfer ionization chamber standards. Results are presented for the reference radiation beam qualities in the range from 25 kV to 50 kV for low energy x rays, including the techniques used for mammography dose traceability. The tungsten generated reference radiation qualities, between 25 kV and 50 kV used for this comparison, are new to NIST; therefore this comparison will serve as the preliminary comparison for NIST and a verification of the primary standard correction factors. The mammography comparison will repeat two previously unpublished comparisons between PTB and NIST. The results show the standards to be in reasonable agreement within the standard uncertainty of the comparison of about 0.4 %.

  12. Comparisons between Intel 386 and i486 microprecessors

    NASA Technical Reports Server (NTRS)

    Liu, Yuan-Kwei

    1989-01-01

    A quick and preliminary comparison is made between the Intel 386 and i486 microprocessors. The following topics are discussed: the i486 key elements, comparison of instruction set architecture, the i486 on-chip cache characteristics, the i486 multiprocessor support, comparison of performance, comparison of power consumption, comparison of radiation hardening potential, and recommendations for the Space Station Freedom (SSF) Data Management System (DMS).

  13. Final report on EURAMET.QM-S6/1195: Bilateral comparison of liquefied hydrocarbon mixtures in constant pressure (piston) cylinders

    NASA Astrophysics Data System (ADS)

    Brown, Andrew S.; Downey, Michael L.; Milton, Martin J. T.; van der Veen, Adriaan M. H.; Zalewska, Ewelina T.; Li, Jianrong

    2013-01-01

    Traceable liquid hydrocarbon mixtures are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas) and LNG (liquefied natural gas), thus meeting the needs of an increasingly large European industrial market. The development of traceable liquid hydrocarbon standards by National Measurement Institutes (NMIs) was still at a relatively early stage at the time this comparison was proposed in 2011. NPL and VSL, who were the only NMIs active in this area, had developed methods for the preparation and analysis of such standards in constant pressure (piston) cylinders, but neither laboratory had Calibration and Measurement Capabilities (CMCs) for these mixtures. This report presents the results of EURAMET 1195, the first comparison of liquid hydrocarbon mixtures between NMIs, which assessed the preparation and analytical capabilities of NPL and VSL for these mixtures. The comparison operated between August 2011 and January 2012. Each laboratory prepared a liquid hydrocarbon standard with nominally the same composition and these standards were exchanged for analysis. The results of the comparison show a good agreement between the laboratories' results and the comparison reference values for the six components with amount fractions greater than 1.0 cmol/mol (propane, propene, iso-butene, n-butane, iso-butane and 1-butene). Measurement of the three components with lower amount fractions (1,3-butadiene, iso-pentane and n-pentane) proved more challenging. In all but one case, the differences from the comparison reference values for these three components were greater than the expanded measurement uncertainty. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual

  14. Transport equations of electrodiffusion processes in the laboratory reference frame.

    PubMed

    Garrido, Javier

    2006-02-23

    The transport equations of electrodiffusion processes use three reference frames for defining the fluxes: Fick's reference in diffusion, solvent-fixed reference in transference numbers, and laboratory fluxes in electric conductivity. The convenience of using only one reference frame is analyzed here from the point of view of the thermodynamics of irreversible processes. A relation between the fluxes of ions and solvent and the electric current density is deduced first from a mass and volume balance. This is then used to show that (i) the laboratory and Fick's diffusion coefficients are identical and (ii) the transference numbers of both the solvent and the ion in the laboratory reference frame are related. Finally, four experimental methods for the measurement of ion transference numbers are analyzed critically. New expressions for evaluating transference numbers for the moving boundary method and the chronopotentiometry technique are deduced. It is concluded that the ion transport equation in the laboratory reference frame plays a key role in the description of electrodiffusion processes.

  15. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standardsa

    PubMed Central

    Halvorsen, Ken; Agris, Paul F.

    2014-01-01

    Measuring interactions between biological molecules is vitally important to both basic and applied research, as well as development of pharmaceuticals. While a wide and growing range of techniques are available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel, or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using Isothermal Titration Calorimetry, Differential Scanning Calorimetry, and UV-Vis monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features including low cost, high purity, easily measureable concentrations, and minimal handling concerns, making them ideal for use as a reference material. PMID:25124363

  16. Report on the bilateral comparison between BIM (Bulgaria) and VSL (The Netherlands)

    NASA Astrophysics Data System (ADS)

    Dekker, Paul; Kunova, Angela; Dierikx, Erik

    2017-01-01

    A bilateral comparison has been organized between VSL, The Netherlands and BIM, Bulgaria in the field of spectral regular transmittance measurements. This comparison is registered as EURAMET project nr. 1073 and EURAMET.PR-K6.2 in the BIPM key comparison database. The aim of the comparison is to demonstrate the improvement of calibration measurement capabilities of BIM in this working field. If this comparison is successful, i.e. the results support the claimed improvement in uncertainties, the improved CMC's for BIM will be included in Appendix C of the CIPM mutual recognition arrangement (MRA). The results of this comparison are linked to key comparison CCPR K6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Post hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.

    PubMed

    Montoro Bustos, Antonio R; Petersen, Elijah J; Possolo, Antonio; Winchester, Michael R

    2015-09-01

    Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

  18. Chemical thermodynamic data. 1. The concept of links to the chemical elements and the historical development of key thermodynamic data

    NASA Astrophysics Data System (ADS)

    Wolery, Thomas J.; Jové Colón, Carlos F.

    2017-09-01

    Chemical thermodynamic data remain a keystone for geochemical modeling and reactive transport simulation as applied to an increasing number of applications in the earth sciences, as well as applications in other areas including metallurgy, material science, and industrial process design. The last century has seen the development of a large body of thermodynamic data and a number of major compilations. The past several decades have seen the development of thermodynamic databases in digital form designed to support computer calculations. However, problems with thermodynamic data appear to be persistent. One problem pertains to the use of inconsistent primary key reference data. Such data pertain to elemental reference forms and key, stoichiometrically simple chemical species including metal oxides, CO2, water, and aqueous species such as Na+ and Cl-. A consistent set of primary key data (standard Gibbs energies, standard enthalpies, and standard entropies for key chemical species) for 298.15 K and 1 bar pressure is essential. Thermochemical convention is to define the standard Gibbs energy and the standard enthalpy of an individual chemical species in terms of formation from reference forms of the constituent chemical elements. We propose a formal concept of "links" to the elemental reference forms. This concept involves a documented understanding of all reactions and calculations leading to values for a formation property (standard Gibbs energy or enthalpy). A valid link consists of two parts: (a) the path of reactions and corrections and (b) the associated data, which are key data. Such a link differs from a bare "key" or "reference" datum in that it requires additional information. Some or all of its associated data may also be key data. In evaluating a reported thermodynamic datum, one should identify the links to the chemical elements, a process which can be time-consuming and which may lead to a dead end (an incomplete link). The use of two or more inconsistent

  19. Self-Efficacy: A Comparison between Clinically Anxious and Non-Referred Youth

    ERIC Educational Resources Information Center

    Landon, Terri M.; Ehrenreich, Jill T.; Pincus, Donna B.

    2007-01-01

    Although diminished self-efficacy has been linked to childhood psychopathology, including depression, it has only recently been studied in relation to childhood anxiety disorders. This study examines the relationship between self-efficacy and self-reported anxiety in children who have been referred for an assessment and possible treatment of…

  20. Issues concerning international comparison of free-field calibrations of acoustical standards

    NASA Astrophysics Data System (ADS)

    Nedzelnitsky, Victor

    2002-11-01

    Primary free-field calibrations of laboratory standard microphones by the reciprocity method establish these microphones as reference standard devices for calibrating working standard microphones, other measuring microphones, and practical instruments such as sound level meters and personal sound exposure meters (noise dosimeters). These primary, secondary, and other calibrations are indispensable to the support of regulatory requirements, standards, and product characterization and quality control procedures important for industry, commerce, health, and safety. International Electrotechnical Commission (IEC) Technical Committee 29 Electroacoustics produces international documentary standards, including standards for primary and secondary free-field calibration and measurement procedures and their critically important application to practical instruments. This paper addresses some issues concerning calibrations, standards activities, and the international key comparison of primary free-field calibrations of IEC-type LS2 laboratory standard microphones that is being planned by the Consultative Committee for Acoustics, Ultrasound, and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM). This comparison will include free-field calibrations by the reciprocity method at participating major national metrology laboratories throughout the world.

  1. A comparison of age, size, and fecundity of harvested and reference White Sucker populations

    USGS Publications Warehouse

    Begley, Meg; Coghlan, Stephen M.; Zydlewski, Joseph D.

    2017-01-01

    White Suckers Catostomus commersonii are an important source of fresh bait for the Maine lobster fishery. The Maine Department of Inland Fisheries and Wildlife began issuing commercial harvest permits in 1991, without reporting requirements or limits on the number of permits. There is recent concern that overfishing may be occurring. To infer impact, we investigated demographic differences between White Sucker populations in lakes open to harvest and those in lakes closed to harvest. Each of three harvested lakes was paired to a nearby closed lake as a reference based on general size, morphometry, and information on harvest pressure. In total, 976 spawning White Suckers were collected from the six lakes in 2014 (120–282 individuals/lake). Fish size, estimated age, fecundity, and mortality rates were compared between lakes. We hypothesized that we would find smaller, younger, and less-fecund individuals in harvested lakes compared to reference lakes. Size and age distributions for both sexes differed between nearly all lake pairs (except between males from one pair). White Suckers from reference lakes were larger and older and had greater gonadosomatic indices and fecundity than fish from harvested lakes. Estimated annual mortality rates were at least twofold higher in harvested lakes than in reference lakes. We detected some differences in von Bertalanffy growth parameters between lake pairs, as might occur under selective harvest pressure. The growth coefficient was smaller for reference lakes than for harvested lakes, while asymptotic length was greater for reference lakes than for harvested lakes. The data suggest that current levels of exploitation are resulting in greater age truncation in existing White Sucker populations.

  2. Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooraghi, Michael R; Sengupta, Manajit; Vignola, Frank

    Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focusesmore » on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.« less

  3. Reference-based source separation method for identification of brain regions involved in a reference state from intracerebral EEG

    PubMed Central

    Samadi, Samareh; Amini, Ladan; Cosandier-Rimélé, Delphine; Soltanian-Zadeh, Hamid; Jutten, Christian

    2013-01-01

    In this paper, we present a fast method to extract the sources related to interictal epileptiform state. The method is based on general eigenvalue decomposition using two correlation matrices during: 1) periods including interictal epileptiform discharges (IED) as a reference activation model and 2) periods excluding IEDs or abnormal physiological signals as background activity. After extracting the most similar sources to the reference or IED state, IED regions are estimated by using multiobjective optimization. The method is evaluated using both realistic simulated data and actual intracerebral electroencephalography recordings of patients suffering from focal epilepsy. These patients are seizure-free after the resective surgery. Quantitative comparisons of the proposed IED regions with the visually inspected ictal onset zones by the epileptologist and another method of identification of IED regions reveal good performance. PMID:23428609

  4. Final report on bilateral comparison SIM.EM-S9.b: Comparison of resistance standards at 1 Ω and 10 kΩ between INIMET (Cuba) and INTI (Argentina), March to October 2012

    NASA Astrophysics Data System (ADS)

    Tonina, A.; Currás, M.; Navarro, M.

    2014-01-01

    The CIPM MRA states that its technical basis is a set of results obtained in a course of time through key comparisons carried out by the Consultative Committees of the CIPM, the BIPM and the Regional Metrology Organizations (RMOs). As part of this process, INTI (Argentina) has participated in several key and supplementary comparisons. By means of procedures for linking key comparison data, a bilateral comparison would help to provide assurance of equality in measurements between the participating laboratories. With this end, the comparison SIM.EM-S9.b of 1 ohm and 10 kiloohm standard resistors of INIMET (Cuba) and INTI was carried out from March to October 2012. The obtained results were very good. They show that the resistance standards maintained by INTI and INIMET were equivalent, within their combined uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Human Exploration of Mars Design Reference Architecture 5.0

    NASA Technical Reports Server (NTRS)

    Drake, Bret G.; Hoffman, Stephen J.; Beaty, David W.

    2009-01-01

    This paper provides a summary of the 2007 Mars Design Reference Architecture 5.0 (DRA 5.0), which is the latest in a series of NASA Mars reference missions. It provides a vision of one potential approach to human Mars exploration including how Constellation systems can be used. The reference architecture provides a common framework for future planning of systems concepts, technology development, and operational testing as well as Mars robotic missions, research that is conducted on the International Space Station, and future lunar exploration missions. This summary the Mars DRA 5.0 provides an overview of the overall mission approach, surface strategy and exploration goals, as well as the key systems and challenges for the first three human missions to Mars.

  6. Final Report: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo

    2015-01-01

    The EURAMET.M.FF-K6 comparison was organized for the purpose of determination of the degree of equivalence of the primary (national) standards for low-pressure gas flow measurement over the range (2 to 100) m3/h and was performed simultaneously with CCM.FF-K6.2011 with the same transfer standard. A rotary gas meter G65 was used as a transfer standard. The measurements were provided by prescribed reference conditions. Fifteen laboratories from EURAMET participated in this key comparison - SMU, Slovakia; PTB, Germany; CEM, Spain; LNE-LADG, France; VSL, Netherlands; CMI, Czech Republic; BEV, Austria; MKEH, Hungary; GUM Poland; SP, Sweden; METAS, Switzerland; DMDM, Serbia; TUBITAK-UME, Turkey; EIM, Greece; IMBiH, Bosnia-Herzegovina. The EURAMET.M.FF-K6 is linked to the CCM.FF-K6.2011 by correcting the results of three linking laboratories (Slovakia SMU, Germany PTB and France LNE LADG). This correction provides an estimate of what would have been the result from the EURAMET.M-FF-K6 participants, if they had actually participated in CCM.FF-K6.2011. According to the evaluation 93.7 % of the results were consistent with KCRV, 3.4 % of the results were in the warning level and 2.9 % of the results were inconsistent. The results of this comparison can be used for review of the CMC tables. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Provincial Comparison of Pharmacist Prescribing in Canada Using Alberta’s Model as the Reference Point

    PubMed Central

    Bhatia, Surya; Simpson, Scot H; Bungard, Tammy

    2017-01-01

    Background In the past decade, pharmacist practice has evolved tremendously in Canada, but the scope of practice varies substantially from one province to another. Objective To describe pharmacists’ scopes of practice relevant to prescribing within various jurisdictions of Canada, using the prescribing model in Alberta (authors’ province) as the reference point. Methods This cross-sectional survey consisted of clinical scenarios for emergency prescribing, adapting or renewing a prescription, and initial-access prescribing for a chronic disease. Pharmacists were asked about their ability to administer injections and to order or access the results of laboratory tests, as well as certification and training requirements and reimbursement models. Results Thirteen pharmacists representing Canadian provinces other than Alberta were surveyed in late 2015, for comparison with Alberta. With specific reference to the scenarios presented, pharmacists were able to prescribe in an emergency in 9 of the 10 provinces, renew prescriptions in all provinces, and adapt prescriptions in 6 provinces. Three provinces required that pharmacists have collaborative practice agreements identifying a specific practice area in order to initiate a prescription for a chronic disease (with 6–12 pharmacists per province having such agreements). Alberta required pharmacists to have authorization, based on a detailed application, in order to initiate any provincially regulated drug (with about 1150 pharmacists having this authorization). Pharmacists were allowed to administer vaccines in 9 provinces, and 5 provinces allowed pharmacists to administer drugs by injection. Three provinces had systems in place for pharmacists to access laboratory test results, and 2 allowed pharmacists to order laboratory tests. Five provinces had government-reimbursed programs in place for select prescribing services; however, all 9 provinces with public vaccination programs reimbursed pharmacists for this service

  8. [Coping with everyday stress in different problem areas- comparison of clinically referred and healthy adolescents].

    PubMed

    Escher, Fabian; Seiffge-Krenke, Inge

    2013-09-01

    Studies are lacking that analyze how clinically referred adolescents and healthy adolescents cope with everyday stressors. Clinically referred adolescents from three problematic domains (diverse disorders including delinquency, drug abuse, and depression) were compared to healthy adolescents using the Coping Across Situations Questionnaire (Seiffge-Krenke, 1995) and a short version of the Youth Self-Report (Achenbach, 1991). The different clinical groups (n = 469) showed unique patterns concerning their coping styles. The group of depressed youth altogether showed lower coping activities. The youth from institutions for drug abusive youth used more dysfunctional coping. The adolescents from youth welfare services (diverse disorders including delinquency) were more active in both dysfunctional and functional coping than the other two clinically referred groups. The control group showed more functional and less dysfunctional coping. The clinically referred adolescents did not differentiate in their coping behavior, depending on the type of stressor. Gender effects were apparent, albeit negligible. Clinically referred youth are unable to adapt their coping behavior according to the given situation.

  9. Reference values of waist circumference and waist/hip ratio in children and adolescents of Mérida, Venezuela: comparison with international references.

    PubMed

    Mederico, Maracelly; Paoli, Mariela; Zerpa, Yajaira; Briceño, Yajaira; Gómez-Pérez, Roald; Martínez, José Luis; Camacho, Nolis; Cichetti, Rosanna; Molina, Zarela; Mora, Yolanda; Valeri, Lenin

    2013-05-01

    To collect regional reference values of waist circumference (WC), and waist/hip ratio (WHR) in children and adolescents from Merida, Venezuela, and to compare them to international references. A total of 919 students aged 9-17 years from public and private educational establishments were assessed. Weight, height, WC, and WHR were measured. Outliers (± 3 SD Z-Score) were excluded from the data collected. Percentile distribution of the tested variables was done by age and sex. Fifty-one percent of subjects were female, and 52.7% were from public institutions. WC (p=0.001) and WHR (p=0.0001) were statistically higher in boys. With advancing age, WC increased in both sexes, while WHR showed the opposite behavior (p=0.0001 for both). The 90th percentile (pc) for WC ranged from 69.7 and 83.6 cm in girls and from 69.2 and 86.7 cm in boys. The 90th pc values of WHR ranged from 0.79 and 0.91 in girls and from 0.86 and 0.93 in boys. Overall, our WC and WHR values were lower than North American values and similar to those of some Latin American references. Percentile reference charts for WC and WHR specific for age and sex, obtained from a representative sample of children and adolescents from Mérida, Venezuela, are provided. They may be used regionally, both for individual assessment and to implement prevention policies. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.

  10. Range Reference Atmosphere 0-70 Km Altitude. Kwajalein Missile Range, Kwajalein, Marshall Islands

    DTIC Science & Technology

    1982-01-01

    DOCUMENT 360-82 KWAJALEIN MISSILE RANGE KWAJALEIN, MARSHALL ISLANDS RANGE REFERENCE ATMOSPHERE 0-70 KM ALTITUDE, C00 L’’I METEOROLOGY GROUP .RANGE...34Reference Atmosphere (Part 1), Kwajale 4n Missile Range, Kwajalein, Marshall Islands ," ADA002664. * 19. KEY WORDS (Continue on revorsae d. If necoeewy...CLASSIFICATION OF TIlS PAGE (Whe~n Data EnterecD -v DOCUMENT 360-82 Vo- KWAJALEIN MISSILE RANGE KWAJALEIN, MARSHALL ISLANDS RANGE REFERENCE ATMOSPHERE 0-70 km

  11. Limited Aspects of Reality: Frames of Reference in Language Assessment

    ERIC Educational Resources Information Center

    Fulcher, Glenn; Svalberg, Agneta

    2013-01-01

    Language testers operate within two frames of reference: norm-referenced (NRT) and criterion-referenced testing (CRT). The former underpins the world of large-scale standardized testing that prioritizes variability and comparison. The latter supports substantive score meaning in formative and domain specific assessment. Some claim that the…

  12. Mixed Methods Research: What Are the Key Issues to Consider?

    ERIC Educational Resources Information Center

    Ghosh, Rajashi

    2016-01-01

    Mixed methods research (MMR) is increasingly becoming a popular methodological approach in several fields due to the promise it holds for comprehensive understanding of complex problems being researched. However, researchers interested in MMR often lack reference to a guide that can explain the key issues pertaining to the paradigm wars…

  13. Qualitative Educational Research in Developing Countries: Current Perspectives. Reference Books in International Education, Volume 35. Garland Reference Library of Social Science, Volume 927.

    ERIC Educational Resources Information Center

    Crossley, Michael, Ed.; Vulliamy, Graham, Ed.

    This book contains 11 essays that offer in-depth accounts of qualitative research in developing countries. Each chapter focuses upon a specific method and considers related theoretical and practical issues with reference to recent experiences in selected developing countries. Key issues addressed include: (1) the identification of appropriate…

  14. Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

    NASA Technical Reports Server (NTRS)

    Novelli, P. C.; Collins, J. E., Jr.; Myers, R. C.; Sachse, G. W.; Scheel, H. E.

    1994-01-01

    The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four

  15. Comparison of ambulatory blood pressure reference standards in children evaluated for hypertension.

    PubMed

    Jones, Deborah P; Richey, Phyllis A; Alpert, Bruce S

    2009-06-01

    The purpose of this study was to systematically compare methods for standardization of blood pressure levels obtained by ambulatory blood pressure monitoring (ABPM) in a group of 111 children studied at our institution. Blood pressure indices, blood pressure loads and standard deviation scores were calculated using the original ABPM and the modified reference standards. Bland-Altman plots and kappa statistics for the level of agreement were generated. Overall, the agreement between the two methods was excellent; however, approximately 5% of children were classified differently by one as compared with the other method. Depending on which version of the German Working Group's reference standards is used for interpretation of ABPM data, the classification of the individual as having hypertension or normal blood pressure may vary.

  16. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. TH-A-204-00: Key Dosimetry Data - Impact of New ICRU Recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair inmore » dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV xrays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and

  18. TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seltzer, S.

    The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair inmore » dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and

  19. Subcarrier Wave Quantum Key Distribution in Telecommunication Network with Bitrate 800 kbit/s

    NASA Astrophysics Data System (ADS)

    Gleim, A. V.; Nazarov, Yu. V.; Egorov, V. I.; Smirnov, S. V.; Bannik, O. I.; Chistyakov, V. V.; Kynev, S. M.; Anisimov, A. A.; Kozlov, S. A.; Vasiliev, V. N.

    2015-09-01

    In the course of work on creating the first quantum communication network in Russia we demonstrated quantum key distribution in metropolitan optical network infrastructure. A single-pass subcarrier wave quantum cryptography scheme was used in the experiments. BB84 protocol with strong reference was chosen for performing key distribution. The registered sifted key rate in an optical cable with 1.5 dB loss was 800 Kbit/s. Signal visibility exceeded 98%, and quantum bit error rate value was 1%. The achieved result is a record for this type of systems.

  20. Key Elements of a Good Mathematics Lesson as Seen by Japanese Junior High School Teachers

    ERIC Educational Resources Information Center

    Ebaeguin, Marlon; Stephens, Max

    2016-01-01

    This study makes a comparison between what literature on Japanese Lesson Study suggests are key elements of a good mathematics lesson and what junior high school mathematics teachers in Japan value in planning their lessons. The teachers' strong consensus in their endorsements of these key elements explains why Japanese teachers strongly support…

  1. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

    PubMed

    Halvorsen, Ken; Agris, Paul F

    2014-11-15

    Measuring interactions between biological molecules is vitally important to both basic and applied research as well as development of pharmaceuticals. Although a wide and growing range of techniques is available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using isothermal titration calorimetry, differential scanning calorimetry, and ultraviolet-visible (UV-vis) monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features, including low cost, high purity, easily measurable concentrations, and minimal handling concerns, making them ideal for use as a reference material. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Functional and proteomic comparison of Bothrops jararaca venom from captive specimens and the Brazilian Bothropic Reference Venom.

    PubMed

    Farias, Iasmim Baptista de; Morais-Zani, Karen de; Serino-Silva, Caroline; Sant'Anna, Sávio S; Rocha, Marisa M T da; Grego, Kathleen F; Andrade-Silva, Débora; Serrano, Solange M T; Tanaka-Azevedo, Anita M

    2018-03-01

    Snake venom is a variable phenotypic trait, whose plasticity and evolution are critical for effective antivenom production. A significant reduction of the number of snake donations to Butantan Institute (São Paulo, Brazil) occurred in recent years, and this fact may impair the production of the Brazilian Bothropic Reference Venom (BBRV). Nevertheless, in the last decades a high number of Bothrops jararaca specimens have been raised in captivity in the Laboratory of Herpetology of Butantan Institute. Considering these facts, we compared the biochemical and biological profiles of B. jararaca venom from captive specimens and BBRV in order to understand the potential effects of snake captivity upon the venom composition. Electrophoretic analysis and proteomic profiling revealed few differences in venom protein bands and some differentially abundant toxins. Comparison of enzymatic activities showed minor differences between the two venoms. Similar cross-reactivity recognition pattern of both venoms by the antibothropic antivenom produced by Butantan Institute was observed. Lethality and neutralization of lethality for B. jararaca venom from captive specimens and BBRV showed similar values. Considering these results we suggest that the inclusion of B. jararaca venom from captive specimens in the composition of BBRV would not interfere with the quality of this reference venom. Snakebite envenomation is a neglected tropical pathology whose treatment is based on the use of specific antivenoms. Bothrops jararaca is responsible for the majority of snakebites in South and Southeastern Brazil. Its venom shows individual, sexual, and ontogenetic variability, however, the effect of animal captivity upon venom composition is unknown. Considering the reduced number of wild-caught snakes donated to Butantan Institute in the last decades, and the increased life expectancy of the snakes raised in captivity in the Laboratory of Herpetology, this work focused on the comparative

  3. Comparison of a 50 mL pycnometer and a 500 mL flask, EURAMET.M.FF.S8 (EURAMET 1297)

    NASA Astrophysics Data System (ADS)

    Mićić, Ljiljana; Batista, Elsa

    2018-01-01

    The purpose of this comparison was to compare the results of the participating laboratories in the calibration of 50 mL pycnometer and 500 mL volumetric flask using the gravimetric method. Laboratories were asked to determined the 'contained' volume of the 50 mL pycnometer and of the 500 mL flask at a reference temperature of 20 °C. The gravimetric method was used for both instruments by all laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Comparison of Fiber Optic Strain Demodulation Implementations

    NASA Technical Reports Server (NTRS)

    Quach, Cuong C.; Vazquez, Sixto L.

    2005-01-01

    NASA Langley Research Center is developing instrumentation based upon principles of Optical Frequency-Domain Reflectometry (OFDR) for the provision of large-scale, dense distribution of strain sensors using fiber optics embedded with Bragg gratings. Fiber Optic Bragg Grating technology enables the distribution of thousands of sensors immune to moisture and electromagnetic interference with negligible weight penalty. At Langley, this technology provides a key component for research and development relevant to comprehensive aerospace vehicle structural health monitoring. A prototype system is under development that includes hardware and software necessary for the acquisition of data from an optical network and conversion of the data into strain measurements. This report documents the steps taken to verify the software that implements the algorithm for calculating the fiber strain. Brief descriptions of the strain measurement system and the test article are given. The scope of this report is the verification of software implementations as compared to a reference model. The algorithm will be detailed along with comparison results.

  5. Program for creating an operating system generation cross reference index (SGINDEX)

    NASA Technical Reports Server (NTRS)

    Barth, C. W.

    1972-01-01

    Computer program to collect key data from Stage Two input of OS/360 system and to prepare formatted listing of index entries collected is discussed. Program eliminates manual paging through system output by providing comprehensive cross reference.

  6. Comparison of ambulatory blood pressure reference standards in children evaluated for hypertension

    PubMed Central

    Jones, Deborah P.; Richey, Phyllis A.; Alpert, Bruce S.

    2009-01-01

    Objective The purpose of this study was to systematically compare methods for standardization of blood pressure levels obtained by ambulatory blood pressure monitoring (ABPM) in a group of 111 children studied at our institution. Methods Blood pressure indices, blood pressure loads and standard deviation scores were calculated using he original ABPM and the modified reference standards. Bland—Altman plots and kappa statistics for the level of agreement were generated. Results Overall, the agreement between the two methods was excellent; however, approximately 5% of children were classified differently by one as compared with the other method. Conclusion Depending on which version of the German Working Group’s reference standards is used for interpretation of ABPM data, the classification of the individual as having hypertension or normal blood pressure may vary. PMID:19433980

  7. APMP supplementary comparison report of absorbed dose rate in tissue for beta radiation (BIPM KCDB: APMP.RI(I)-S2)

    NASA Astrophysics Data System (ADS)

    Kato, M.; Kurosawa, T.; Saito, N.; Kadni, T. B.; Kim, I. J.; Kim, B. C.; Yi, C.-Y.; Pungkun, V.; Chu, C.-H.

    2017-01-01

    The supplementary comparison of absorbed dose rate in tissue for beta radiation (APMP.RI(I)-S2) was performed with five national metrology institutes in 2013 and 2014. Two commercial thin window ionization chambers were used as transfer instruments and circulated among the participants. Two of the NMIs measured the calibration coefficients of the chambers in reference fields produced from Pm-147, Kr-85 and Sr-90/Y-90, while the other three measured those only in Sr-90/Y-90 beta-particle field. The degree of equivalence for the participants was determined and this comparison verifies the calibration capabilities of the participating laboratories. In addition, most of the results of this comparison are consistent with another international comparison (EUROMET.RI(I)-S2) reported before this work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Environmental and economic comparisons of the satellite power system and six alternative energy technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitfield, R.G.; Habegger, L.J.; Levine, E.P.

    1981-04-01

    The objective of the comparative assessment is to provide an initial, traceable and consistent comparison of the SPS and selected current, near-term, and advanced energy technologies. Terrestrial alternatives were selected, and their cost, performance, and environmental and societal attributes were specified for use in the comparison with the SPS in the post-2000 era. The framework for comparisons was established. The SPS was compared with alternative systems in terms of key issues such as life-cycle cost and environmental impacts. The results of the assessments were assembled and integrated into a consistent comparative assessment. Environmental and economic effects are evaluated, which weremore » subdivided into the following issue areas: human health and safety, environmental welfare, resources (land, materials, energy, water, labor), macroeconomics, socioeconomics, and institutional. These evaluations were based on technology characterization data and alternative futures scenarios, which were developed as part of CDEP by supporting studies. The technologies and the scenarios are described. An additional major issue area concerned the cost and performance of the SPS and the alternative technologies: results in this area provided part of the basis of the macroeconomic analyses. 159 references.« less

  9. Levelized Cost of Energy Analysis of Marine and Hydrokinetic Reference Models: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenne, D. S.; Yu, Y. H.; Neary, V.

    2015-04-24

    In 2010 the U.S. Department of Energy initiated the development of six marine energy converter reference models. The reference models are point designs of well-known marine energy converters. Each device was designed to operate in a specific marine resource, instead of a generic device that can be deployed at any location. This method allows each device to be used as a benchmark for future reference model to benchmark future devices. The six designs consist of three current energy converters and three wave energy converters. The reference model project has generated both technical and economic data sets that are available inmore » the public domain. The methodology to calculate the levelized cost of energy for the reference model project and an overall comparison of the cost of energy from these six reference-model designs are presented in this paper.« less

  10. Key components of financial-analysis education for clinical nurses.

    PubMed

    Lim, Ji Young; Noh, Wonjung

    2015-09-01

    In this study, we identified key components of financial-analysis education for clinical nurses. We used a literature review, focus group discussions, and a content validity index survey to develop key components of financial-analysis education. First, a wide range of references were reviewed, and 55 financial-analysis education components were gathered. Second, two focus group discussions were performed; the participants were 11 nurses who had worked for more than 3 years in a hospital, and nine components were agreed upon. Third, 12 professionals, including professors, nurse executive, nurse managers, and an accountant, participated in the content validity index. Finally, six key components of financial-analysis education were selected. These key components were as follows: understanding the need for financial analysis, introduction to financial analysis, reading and implementing balance sheets, reading and implementing income statements, understanding the concepts of financial ratios, and interpretation and practice of financial ratio analysis. The results of this study will be used to develop an education program to increase financial-management competency among clinical nurses. © 2015 Wiley Publishing Asia Pty Ltd.

  11. Final report on the regional supplementary comparison APMP.AUV.A-S1

    NASA Astrophysics Data System (ADS)

    Plangsangmas, Virat; Leeudomwong, Surat; Scott, Andrew; Zhong, Bo; Huang, Yuchung

    2014-01-01

    A regional supplementary comparison APMP.AUV.A-S1 has been carried out for the measurement of sound pressure level, frequency and total distortion of a multi-frequency sound calibrator. The role of the Pilot laboratory was undertaken by the National Institute of Metrology (Thailand) (NIMT). The multi-frequency sound calibrator was circulated through thirteen National Metrology Institutes (NMIs). Two NMIs were added to the original time schedule after starting the circulation. The measurements took place between September 2008 and July 2010. This report includes the measurement results from all the participants. Supplementary Comparison Reference Values (SCRVs) have been determined from the results. Deviations from the SCRVs are mostly within declared expanded uncertainties. It has been found that a term for the inherent instability in this type of device needs to be included in any uncertainty budget, and a recommended minimum value of this has been given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Six-State Quantum Key Distribution Using Photons with Orbital Angular Momentum

    NASA Astrophysics Data System (ADS)

    Li, Jun-Lin; Wang, Chuan

    2010-11-01

    A new implementation of high-dimensional quantum key distribution (QKD) protocol is discussed. Using three mutual unbiased bases, we present a d-level six-state QKD protocol that exploits the orbital angular momentum with the spatial mode of the light beam. The protocol shows that the feature of a high capacity since keys are encoded using photon modes in d-level Hilbert space. The devices for state preparation and measurement are also discussed. This protocol has high security and the alignment of shared reference frames is not needed between sender and receiver.

  13. A Comparison of One Time Pad Random Key Generation using Linear Congruential Generator and Quadratic Congruential Generator

    NASA Astrophysics Data System (ADS)

    Apdilah, D.; Harahap, M. K.; Khairina, N.; Husein, A. M.; Harahap, M.

    2018-04-01

    One Time Pad algorithm always requires a pairing of the key for plaintext. If the length of keys less than a length of the plaintext, the key will be repeated until the length of the plaintext same with the length of the key. In this research, we use Linear Congruential Generator and Quadratic Congruential Generator for generating a random number. One Time Pad use a random number as a key for encryption and decryption process. Key will generate the first letter from the plaintext, we compare these two algorithms in terms of time speed encryption, and the result is a combination of OTP with LCG faster than the combination of OTP with QCG.

  14. References for Haplotype Imputation in the Big Data Era

    PubMed Central

    Li, Wenzhi; Xu, Wei; Li, Qiling; Ma, Li; Song, Qing

    2016-01-01

    Imputation is a powerful in silico approach to fill in those missing values in the big datasets. This process requires a reference panel, which is a collection of big data from which the missing information can be extracted and imputed. Haplotype imputation requires ethnicity-matched references; a mismatched reference panel will significantly reduce the quality of imputation. However, currently existing big datasets cover only a small number of ethnicities, there is a lack of ethnicity-matched references for many ethnic populations in the world, which has hampered the data imputation of haplotypes and its downstream applications. To solve this issue, several approaches have been proposed and explored, including the mixed reference panel, the internal reference panel and genotype-converted reference panel. This review article provides the information and comparison between these approaches. Increasing evidence showed that not just one or two genetic elements dictate the gene activity and functions; instead, cis-interactions of multiple elements dictate gene activity. Cis-interactions require the interacting elements to be on the same chromosome molecule, therefore, haplotype analysis is essential for the investigation of cis-interactions among multiple genetic variants at different loci, and appears to be especially important for studying the common diseases. It will be valuable in a wide spectrum of applications from academic research, to clinical diagnosis, prevention, treatment, and pharmaceutical industry. PMID:27274952

  15. Final report on SIM.T-S5: comparison of the calibration of 100 Ω platinum resistance thermometers

    NASA Astrophysics Data System (ADS)

    del Campo, D.; García, S.; Velasquez, A.; Medrano, J. A.; Solano, A.; Torres, H. E.

    2015-01-01

    An International Comparison on industrial Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Panama, Honduras, El Salvador, Costa Rica and Nicaragua began in 2013 and was successfully completed in 2014. Two PRTs were circulated (hand carried) and compared in the range from -38.8 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, acted as the pilot laboratory providing the reference value of the comparison. The thermometers have shown an acceptable behavior throughout the comparison, therefore the results can be considered valid for comparing the measurement capabilities of the participant laboratories. The equivalence between the participant laboratories in the calibration of platinum resistance thermometers by comparison in the range from -38,8 °C up to 250 °C has been demonstrated in almost all cases. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Nursing Reference Center: a point-of-care resource.

    PubMed

    Vardell, Emily; Paulaitis, Gediminas Geddy

    2012-01-01

    Nursing Reference Center is a point-of-care resource designed for the practicing nurse, as well as nursing administrators, nursing faculty, and librarians. Users can search across multiple resources, including topical Quick Lessons, evidence-based care sheets, patient education materials, practice guidelines, and more. Additional features include continuing education modules, e-books, and a new iPhone application. A sample search and comparison with similar databases were conducted.

  17. Hemifield-dependent N1 and event-related theta/delta oscillations: An unbiased comparison of surface Laplacian and common EEG reference choices

    PubMed Central

    Kayser, Jürgen; Tenke, Craig E.

    2015-01-01

    Surface Laplacian methodology has been used to reduce the impact of volume conduction and arbitrary choice of EEG recording reference for the analysis of surface potentials. However, the empirical implications of employing these different transformations to the same EEG data remain obscure. This study directly compared the statistical effects of four commonly-used (nose, linked mastoids, average) or recommended (reference electrode standardization technique [REST]) references and their spherical spline current source density (CSD) transformation for a large data set stemming from a well-understood experimental manipulation. ERPs (72 sites) recorded from 130 individuals during a visual half-field paradigm with highly-controlled emotional stimuli were characterized by mid-parietooccipital N1 (125 ms peak latency) and event-related synchronization (ERS) of theta/delta (160 ms), which were most robust over the contralateral hemisphere. All five data transformations were rescaled to the same covariance and submitted to a single temporal or time-frequency PCA (Varimax) to yield simplified estimates of N1 or theta/delta ERS. Unbiased nonparametric permutation tests revealed that these hemifield-dependent asymmetries were by far most focal and prominent for CSD data, despite all transformations showing maximum effects at mid-parietooccipital sites. Employing smaller subsamples (signal-to-noise) or window-based ERP/ERS amplitudes did not affect these comparisons. Furthermore, correlations between N1 and theta/delta ERS at these sites were strongest for CSD and weakest for nose-referenced data. Contrary to the common notion that the spatial high pass filter properties of a surface Laplacian reduce important contributions of neuronal generators to the EEG signal, the present findings demonstrate that instead volume conduction inherent in surface potentials weakens the representation of neuronal activation patterns at scalp that directly reflect regional brain activity. PMID

  18. An evaluation of selected herbal reference texts and comparison to published reports of adverse herbal events.

    PubMed

    Haller, Christine A; Anderson, Ilene B; Kim, Susan Y; Blanc, Paul D

    2002-01-01

    There has been a recent proliferation of medical reference texts intended to guide practitioners whose patients use herbal therapies. We systematically assessed six herbal reference texts to evaluate the information they contain on herbal toxicity. We selected six major herbal references published from 1996 to 2000 to evaluate the adequacy of their toxicological information in light of published adverse events. To identify herbs most relevant to toxicology, we reviewed herbal-related calls to our regional California Poison Control System, San Francisco division (CPCS-SF) in 1998 and identified the 12 herbs (defined as botanical dietary supplements) most frequently involved in these CPCS-SF referrals. We searched Medline (1966 to 2000) to identify published reports of adverse effects potentially related to these same 12 herbs. We scored each herbal reference text on the basis of information inclusiveness for the target 12 herbs, with a maximal overall score of 3. The herbs, identified on the basis of CPCS-SF call frequency were: St John's wort, ma huang, echinacea, guarana, ginkgo, ginseng, valerian, tea tree oil, goldenseal, arnica, yohimbe and kava kava. The overall herbal reference scores ranged from 2.2 to 0.4 (median 1.1). The Natural Medicines Comprehensive Database received the highest overall score and was the most complete and useful reference source. All of the references, however, lacked sufficient information on management of herbal medicine overdose, and several had incorrect overdose management guidelines that could negatively impact patient care. Current herbal reference texts do not contain sufficient information for the assessment and management of adverse health effects of botanical therapies.

  19. Legislation on violence against women: overview of key components.

    PubMed

    Ortiz-Barreda, Gaby; Vives-Cases, Carmen

    2013-01-01

    This study aimed to determine if legislation on violence against women (VAW) worldwide contains key components recommended by the Pan American Health Organization (PAHO) and the United Nations (UN) to help strengthen VAW prevention and provide better integrated victim protection, support, and care. A systematic search for VAW legislation using international legal databases and other electronic sources plus data from previous research identified 124 countries/territories with some type of VAW legislation. Full legal texts were found for legislation from 104 countries/territories. Those available in English, Portuguese, and Spanish were downloaded and compiled and the selection criteria applied (use of any of the common terms related to VAW, including intimate partner violence (IPV), and reference to at least two of six sectors (education, health, judicial system, mass media, police, and social services) with regard to VAW interventions (protection, support, and care). A final sample from 80 countries/territories was selected and analyzed for the presence of key components recommended by PAHO and the UN (reference to the term "violence against women" in the title; definitions of different types of VAW; identification of women as beneficiaries; and promotion of (reference to) the participation of multiple sectors in VAW interventions). Few countries/territories specifically identified women as the beneficiaries of their VAW legislation, including those that labeled their legislation "domestic violence" law ( n = 51), of which only two explicitly mentioned women as complainants/survivors. Only 28 countries/territories defined the main forms of VAW (economic, physical, psychological, and sexual) in their VAW legislation. Most highlighted the role of the judicial system, followed by that of social services and the police. Only 28 mentioned the health sector. Despite considerable efforts worldwide to strengthen VAW legislation, most VAW laws do not incorporate the key

  20. Continuing Education and the Reference Librarian in the Academic and Research Library.

    ERIC Educational Resources Information Center

    Stieg, Margaret F.

    1980-01-01

    Reading is the key for reference librarians to increase general and subject knowledge for continuing professional growth. Continuing education has been limited in practice and thinking to the technical aspects of the profession. (RAA)

  1. Determination of reference ranges for elements in human scalp hair.

    PubMed

    Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W

    1998-06-01

    Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.

  2. Comparing the biocidal properties of non-thermal plasma sources by reference protocol

    NASA Astrophysics Data System (ADS)

    Khun, Josef; Jirešová, Jana; Kujalová, Lucie; Hozák, Pavel; Scholtz, Vladimír

    2017-10-01

    The previously proposed reference protocol enabling easy comparison of biocidal properties of different non-thermal plasma sources has been followed and discussed. For inactivation tests the reference protocol has used spores of Gram positive bacterium Bacillus subtilis (ATCC 6633) deposited on a polycarbonate membrane as reference sample. In this work, biocidal properties of a negative glow corona, positive streamer corona, positive transient spark and cometary discharges are being compared in both open air and closed apparatus. Despite the total number of bacteria surviving 1 h exposure has decreased by up to 7 orders in closed apparatus, in open one, only weak inhibition bactericidal effect has been observed.

  3. Comparison of the Equine Reference Sequence with Its Sanger Source Data and New Illumina Reads

    PubMed Central

    Rebolledo-Mendez, Jovan; Hestand, Matthew S.; Coleman, Stephen J.; Zeng, Zheng; Orlando, Ludovic; MacLeod, James N.; Kalbfleisch, Ted

    2015-01-01

    The reference assembly for the domestic horse, EquCab2, published in 2009, was built using approximately 30 million Sanger reads from a Thoroughbred mare named Twilight. Contiguity in the assembly was facilitated using nearly 315 thousand BAC end sequences from Twilight’s half brother Bravo. Since then, it has served as the foundation for many genome-wide analyses that include not only the modern horse, but ancient horses and other equid species as well. As data mapped to this reference has accumulated, consistent variation between mapped datasets and the reference, in terms of regions with no read coverage, single nucleotide variants, and small insertions/deletions have become apparent. In many cases, it is not clear whether these differences are the result of true sequence variation between the research subjects’ and Twilight’s genome or due to errors in the reference. EquCab2 is regarded as “The Twilight Assembly.” The objective of this study was to identify inconsistencies between the EquCab2 assembly and the source Twilight Sanger data used to build it. To that end, the original Sanger and BAC end reads have been mapped back to this equine reference and assessed with the addition of approximately 40X coverage of new Illumina Paired-End sequence data. The resulting mapped datasets identify those regions with low Sanger read coverage, as well as variation in genomic content that is not consistent with either the original Twilight Sanger data or the new genomic sequence data generated from Twilight on the Illumina platform. As the haploid EquCab2 reference assembly was created using Sanger reads derived largely from a single individual, the vast majority of variation detected in a mapped dataset comprised of those same Sanger reads should be heterozygous. In contrast, homozygous variations would represent either errors in the reference or contributions from Bravo's BAC end sequences. Our analysis identifies 720,843 homozygous discrepancies between new

  4. Evaluating the Tensile Properties of Aluminum Foundry Alloys through Reference Castings-A Review.

    PubMed

    Anilchandra, A R; Arnberg, Lars; Bonollo, Franco; Fiorese, Elena; Timelli, Giulio

    2017-08-30

    The tensile properties of an alloy can be exploited if detrimental defects and imperfections of the casting are minimized and the microstructural characteristics are optimized through several strategies that involve die design, process management and metal treatments. This paper presents an analysis and comparison of the salient characteristics of the reference dies proposed in the literature, both in the field of pressure and gravity die-casting. The specimens produced with these reference dies, called separately poured specimens, are effective tools for the evaluation and comparison of the tensile and physical behaviors of Al-Si casting alloys. Some of the findings of the present paper have been recently developed in the frame of the European StaCast project whose results are complemented here with some more recent outcomes and a comprehensive analysis and discussion.

  5. Evaluating the Tensile Properties of Aluminum Foundry Alloys through Reference Castings—A Review

    PubMed Central

    Anilchandra, A.R.; Arnberg, Lars; Bonollo, Franco; Fiorese, Elena

    2017-01-01

    The tensile properties of an alloy can be exploited if detrimental defects and imperfections of the casting are minimized and the microstructural characteristics are optimized through several strategies that involve die design, process management and metal treatments. This paper presents an analysis and comparison of the salient characteristics of the reference dies proposed in the literature, both in the field of pressure and gravity die-casting. The specimens produced with these reference dies, called separately poured specimens, are effective tools for the evaluation and comparison of the tensile and physical behaviors of Al-Si casting alloys. Some of the findings of the present paper have been recently developed in the frame of the European StaCast project whose results are complemented here with some more recent outcomes and a comprehensive analysis and discussion. PMID:28867796

  6. Four-dimensional key design in amplitude, phase, polarization and distance for optical encryption based on polarization digital holography and QR code.

    PubMed

    Lin, Chao; Shen, Xueju; Li, Baochen

    2014-08-25

    We demonstrate that all parameters of optical lightwave can be simultaneously designed as keys in security system. This multi-dimensional property of key can significantly enlarge the key space and further enhance the security level of the system. The single-shot off-axis digital holography with orthogonal polarized reference waves is employed to perform polarization state recording on object wave. Two pieces of polarization holograms are calculated and fabricated to be arranged in reference arms to generate random amplitude and phase distribution respectively. When reconstruction, original information which is represented with QR code can be retrieved using Fresnel diffraction with decryption keys and read out noise-free. Numerical simulation results for this cryptosystem are presented. An analysis on the key sensitivity and fault tolerance properties are also provided.

  7. Reference aquaplanet climate in the Community Atmosphere Model, Version 5

    DOE PAGES

    Medeiros, Brian; Williamson, David L.; Olson, Jerry G.

    2016-03-18

    In this study, fundamental characteristics of the aquaplanet climate simulated by the Community Atmosphere Model, Version 5.3 (CAM5.3) are presented. The assumptions and simplifications of the configuration are described. A 16 year long, perpetual equinox integration with prescribed SST using the model’s standard 18 grid spacing is presented as a reference simulation. Statistical analysis is presented that shows similar aquaplanet configurations can be run for about 2 years to obtain robust climatological structures, including global and zonal means, eddy statistics, and precipitation distributions. Such a simulation can be compared to the reference simulation to discern differences in the climate, includingmore » an assessment of confidence in the differences. To aid such comparisons, the reference simulation has been made available via earthsystemgrid.org. Examples are shown comparing the reference simulation with simulations from the CAM5 series that make different microphysical assumptions and use a different dynamical core.« less

  8. The Influence of Social Comparison and Peer Group Size on Risky Decision-Making.

    PubMed

    Wang, Dawei; Zhu, Liping; Maguire, Phil; Liu, Yixin; Pang, Kaiyuan; Li, Zhenying; Hu, Yixin

    2016-01-01

    This study explores the influence of different social reference points and different comparison group sizes on risky decision-making. Participants were presented with a scenario describing an exam, and presented with the opportunity of making a risky decision in the context of different information provided about the performance of their peers. We found that behavior was influenced, not only by comparison with peers, but also by the size of the comparison group. Specifically, the larger the reference group, the more polarized the behavior it prompted. In situations describing social loss, participants were led to make riskier decisions after comparing themselves against larger groups, while in situations describing social gain, they become more risk averse. These results indicate that decision making is influenced both by social comparison and the number of people making up the social reference group.

  9. The Influence of Social Comparison and Peer Group Size on Risky Decision-Making

    PubMed Central

    Wang, Dawei; Zhu, Liping; Maguire, Phil; Liu, Yixin; Pang, Kaiyuan; Li, Zhenying; Hu, Yixin

    2016-01-01

    This study explores the influence of different social reference points and different comparison group sizes on risky decision-making. Participants were presented with a scenario describing an exam, and presented with the opportunity of making a risky decision in the context of different information provided about the performance of their peers. We found that behavior was influenced, not only by comparison with peers, but also by the size of the comparison group. Specifically, the larger the reference group, the more polarized the behavior it prompted. In situations describing social loss, participants were led to make riskier decisions after comparing themselves against larger groups, while in situations describing social gain, they become more risk averse. These results indicate that decision making is influenced both by social comparison and the number of people making up the social reference group. PMID:27582723

  10. Final report on the key comparison, CCM.M.P-K15.1 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Hongyan, Yu

    2017-01-01

    At the CCM WG-LP meeting in Berlin in April 2011 the National Institute of Metrology of the people's republic of China asked for an opportunity to be linked to the CCM.M.P-K15 comparison which just ended. METAS, which had been active as pilot for the CCM.M.P-K15, agreed to make a link with NIM. The NIM introduced a new static expansion system in his laboratory. Two spinning rotor gauges and a control electronic are used as transfer standard. The circulation of the transfer standard was made in spring 2012. The drift of the accommodation coefficient of the two SRG was measured by the pilot before and after the comparison. The stability of the transfer standards was excellent and the equivalence between METAS and NIM has been demonstrated. A link to the CCM.M.P­K15 has been established using the results from METAS. It has been possible to achieve a link with a small uncertainty due to the strong correlation of the measurements of METAS in the two comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Comparison of Sofia Legionella FIA and BinaxNOW® Legionella urinary antigen card in two national reference centers.

    PubMed

    Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S

    2015-09-01

    The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.

  12. SUPPLEMENTARY COMPARISON: EUROMET.L-S10 Comparison of squareness measurements

    NASA Astrophysics Data System (ADS)

    Mokros, Jiri

    2005-01-01

    The idea of performing a comparison of squareness resulted from the need to review the MRA Appendix C, Category 90° square. At its meeting in October 1999 (in Prague) it was decided upon a first comparison of squareness measurements in the framework of EUROMET, numbered #570, starting in 2000, with the Slovak Institute of Metrology (SMU) as the pilot laboratory. During the preparation stage of the project, it was agreed that it should be submitted as a EUROMET supplementary comparison in the framework of the Mutual Recognition Arrangement (MRA) of the Metre Convention and would boost confidence in calibration and measurement certificates issued by the participating national metrology institutes. The aim of the comparison of squareness measurement was to compare and verify the declared calibration measurement capabilities of participating laboratories and to investigate the effect of systematic influences in the measurement process and their elimination. Eleven NMIs from the EUROMET region carried out this project. Two standards were calibrated: granite squareness standard of rectangular shape, cylindrical squareness standard of steel with marked positions for the profile lines. The following parameters had to be calibrated: granite squareness standard: interior angle γB between two lines AB and AC (envelope - LS regression) fitted through the measured profiles, and/or granite squareness standard: interior angle γLS between two LS regression lines AB and AC fitted through the measured profiles, cylindrical squareness standard: interior angles γ0°, γ90°, γ180°, γ270° between the LS regression line fitted through the measurement profiles at 0°, 90°, 180°, 270° and the envelope plane of the basis (resting on a surface plate), local LS straightness deviation for all measured profiles (2 and 4) of both standards. The results of the comparison are the deviations of profiles and angles measured by the individual NMIs from the reference values. These resulted

  13. Continuous high speed coherent one-way quantum key distribution.

    PubMed

    Stucki, Damien; Barreiro, Claudio; Fasel, Sylvain; Gautier, Jean-Daniel; Gay, Olivier; Gisin, Nicolas; Thew, Rob; Thoma, Yann; Trinkler, Patrick; Vannel, Fabien; Zbinden, Hugo

    2009-08-03

    Quantum key distribution (QKD) is the first commercial quantum technology operating at the level of single quanta and is a leading light for quantum-enabled photonic technologies. However, controlling these quantum optical systems in real world environments presents significant challenges. For the first time, we have brought together three key concepts for future QKD systems: a simple high-speed protocol; high performance detection; and integration both, at the component level and for standard fibre network connectivity. The QKD system is capable of continuous and autonomous operation, generating secret keys in real time. Laboratory and field tests were performed and comparisons made with robust InGaAs avalanche photodiodes and superconducting detectors. We report the first real world implementation of a fully functional QKD system over a 43 dB-loss (150 km) transmission line in the Swisscom fibre optic network where we obtained average real-time distribution rates over 3 hours of 2.5 bps.

  14. Ask Here PA: Large-Scale Synchronous Virtual Reference for Pennsylvania

    ERIC Educational Resources Information Center

    Mariner, Vince

    2008-01-01

    Ask Here PA is Pennsylvania's new statewide live chat reference and information service. This article discusses the key strategies utilized by Ask Here PA administrators to recruit participating libraries to contribute staff time to the service, the importance of centralized staff training, the main aspects of staff training, and activating the…

  15. Two low coverage bird genomes and a comparison of reference-guided versus de novo genome assemblies.

    PubMed

    Card, Daren C; Schield, Drew R; Reyes-Velasco, Jacobo; Fujita, Matthew K; Andrew, Audra L; Oyler-McCance, Sara J; Fike, Jennifer A; Tomback, Diana F; Ruggiero, Robert P; Castoe, Todd A

    2014-01-01

    As a greater number and diversity of high-quality vertebrate reference genomes become available, it is increasingly feasible to use these references to guide new draft assemblies for related species. Reference-guided assembly approaches may substantially increase the contiguity and completeness of a new genome using only low levels of genome coverage that might otherwise be insufficient for de novo genome assembly. We used low-coverage (∼3.5-5.5x) Illumina paired-end sequencing to assemble draft genomes of two bird species (the Gunnison Sage-Grouse, Centrocercus minimus, and the Clark's Nutcracker, Nucifraga columbiana). We used these data to estimate de novo genome assemblies and reference-guided assemblies, and compared the information content and completeness of these assemblies by comparing CEGMA gene set representation, repeat element content, simple sequence repeat content, and GC isochore structure among assemblies. Our results demonstrate that even lower-coverage genome sequencing projects are capable of producing informative and useful genomic resources, particularly through the use of reference-guided assemblies.

  16. Two low coverage bird genomes and a comparison of reference-guided versus de novo genome assemblies

    USGS Publications Warehouse

    Card, Daren C.; Schield, Drew R.; Reyes-Velasco, Jacobo; Fujita, Matthre K.; Andrew, Audra L.; Oyler-McCance, Sara J.; Fike, Jennifer A.; Tomback, Diana F.; Ruggiero, Robert P.; Castoe, Todd A.

    2014-01-01

    As a greater number and diversity of high-quality vertebrate reference genomes become available, it is increasingly feasible to use these references to guide new draft assemblies for related species. Reference-guided assembly approaches may substantially increase the contiguity and completeness of a new genome using only low levels of genome coverage that might otherwise be insufficient for de novo genome assembly. We used low-coverage (~3.5–5.5x) Illumina paired-end sequencing to assemble draft genomes of two bird species (the Gunnison Sage-Grouse, Centrocercus minimus, and the Clark's Nutcracker, Nucifraga columbiana). We used these data to estimate de novo genome assemblies and reference-guided assemblies, and compared the information content and completeness of these assemblies by comparing CEGMA gene set representation, repeat element content, simple sequence repeat content, and GC isochore structure among assemblies. Our results demonstrate that even lower-coverage genome sequencing projects are capable of producing informative and useful genomic resources, particularly through the use of reference-guided assemblies.

  17. Multiparty quantum key agreement protocol based on locally indistinguishable orthogonal product states

    NASA Astrophysics Data System (ADS)

    Jiang, Dong-Huan; Xu, Guang-Bao

    2018-07-01

    Based on locally indistinguishable orthogonal product states, we propose a novel multiparty quantum key agreement (QKA) protocol. In this protocol, the private key information of each party is encoded as some orthogonal product states that cannot be perfectly distinguished by local operations and classical communications. To ensure the security of the protocol with small amount of decoy particles, the different particles of each product state are transmitted separately. This protocol not only can make each participant fairly negotiate a shared key, but also can avoid information leakage in the maximum extent. We give a detailed security proof of this protocol. From comparison result with the existing QKA protocols, we can know that the new protocol is more efficient.

  18. Bilateral comparison on electric field measurements between TÜBİTAK UME and SASO NMCC

    NASA Astrophysics Data System (ADS)

    Aslan, Çağlar; Alrobaish, Abdullah M.; Şen, Osman

    2017-01-01

    Electromagnetic (EM) probes are widely utilized in the measurement of EM fields for non-ionizing radiation, electromagnetic compatibility (EMC) testing and other applications in the frequency range 5 Hz-60 GHz. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as IEEE 1309. The existing NMIs or emerging NMIs should refer to the international comparison measurements in order to assure the quality of their measurement results. Therefore, the electric field comparison measurements organized by TUBITAK UME were performed between TUBITAK UME and SASO NMCC at the 100 Hz, 1 kHz, 10 MHz, 100 MHz, 1 GHz, 10 GHz and 18 GHz frequencies in order to obtain the correction factors of the electric field probes. The comparison measurements were carried out in accordance with the Technical Protocol prepared by TUBITAK UME. The measurements started in October 2017 and were completed in January 2017. There was good agreement found for the correction factors. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Reinforcer control by comparison-stimulus color and location in a delayed matching-to-sample task.

    PubMed

    Alsop, Brent; Jones, B Max

    2008-05-01

    Six pigeons were trained in a delayed matching-to-sample task involving bright- and dim-yellow samples on a central key, a five-peck response requirement to either sample, a constant 1.5-s delay, and the presentation of comparison stimuli composed of red on the left key and green on the right key or vice versa. Green-key responses were occasionally reinforced following the dimmer-yellow sample, and red-key responses were occasionally reinforced following the brighter-yellow sample. Reinforcer delivery was controlled such that the distribution of reinforcers across both comparison-stimulus color and comparison-stimulus location could be varied systematically and independently across conditions. Matching accuracy was high throughout. The ratio of left to right side-key responses increased as the ratio of left to right reinforcers increased, the ratio of red to green responses increased as the ratio of red to green reinforcers increased, and there was no interaction between these variables. However, side-key biases were more sensitive to the distribution of reinforcers across key location than were comparison-color biases to the distribution of reinforcers across key color. An extension of Davison and Tustin's (1978) model of DMTS performance fit the data well, but the results were also consistent with an alternative theory of conditional discrimination performance (Jones, 2003) that calls for a conceptually distinct quantitative model.

  20. The GCOS Reference Upper-Air Network (GRUAN)

    NASA Astrophysics Data System (ADS)

    Vömel, H.; Berger, F. H.; Immler, F. J.; Seidel, D.; Thorne, P.

    2009-04-01

    While the global upper-air observing network has provided useful observations for operational weather forecasting for decades, its measurements lack the accuracy and long-term continuity needed for understanding climate change. Consequently, the scientific community faces uncertainty on such key issues as the trends of temperature in the upper troposphere and stratosphere or the variability and trends of stratospheric water vapour. To address these shortcomings, and to ensure that future climate records will be more useful than the records to date, the Global Climate Observing System (GCOS) program initiated the GCOS Reference Upper Air Network (GRUAN). GRUAN will be a network of about 30-40 observatories with a representative sampling of geographic regions and surface types. These stations will provide upper-air reference observations of the essential climate variables, i.e. temperature, geopotential, humidity, wind, radiation and cloud properties using specialized radiosondes and complementary remote sensing profiling instrumentation. Long-term stability, quality assurance / quality control, and a detailed assessment of measurement uncertainties will be the key aspects of GRUAN observations. The network will not be globally complete but will serve to constrain and adjust data from more spatially comprehensive global observing systems including satellites and the current radiosonde networks. This paper outlines the scientific rationale for GRUAN, its role in the Global Earth Observation System of Systems, network requirements and likely instrumentation, management structure, current status and future plans.

  1. Reference-guided assembly of four diverse Arabidopsis thaliana genomes

    PubMed Central

    Schneeberger, Korbinian; Ossowski, Stephan; Ott, Felix; Klein, Juliane D.; Wang, Xi; Lanz, Christa; Smith, Lisa M.; Cao, Jun; Fitz, Joffrey; Warthmann, Norman; Henz, Stefan R.; Huson, Daniel H.; Weigel, Detlef

    2011-01-01

    We present whole-genome assemblies of four divergent Arabidopsis thaliana strains that complement the 125-Mb reference genome sequence released a decade ago. Using a newly developed reference-guided approach, we assembled large contigs from 9 to 42 Gb of Illumina short-read data from the Landsberg erecta (Ler-1), C24, Bur-0, and Kro-0 strains, which have been sequenced as part of the 1,001 Genomes Project for this species. Using alignments against the reference sequence, we first reduced the complexity of the de novo assembly and later integrated reads without similarity to the reference sequence. As an example, half of the noncentromeric C24 genome was covered by scaffolds that are longer than 260 kb, with a maximum of 2.2 Mb. Moreover, over 96% of the reference genome was covered by the reference-guided assembly, compared with only 87% with a complete de novo assembly. Comparisons with 2 Mb of dideoxy sequence reveal that the per-base error rate of the reference-guided assemblies was below 1 in 10,000. Our assemblies provide a detailed, genomewide picture of large-scale differences between A. thaliana individuals, most of which are difficult to access with alignment-consensus methods only. We demonstrate their practical relevance in studying the expression differences of polymorphic genes and show how the analysis of sRNA sequencing data can lead to erroneous conclusions if aligned against the reference genome alone. Genome assemblies, raw reads, and further information are accessible through http://1001genomes.org/projects/assemblies.html. PMID:21646520

  2. Key-value store with internal key-value storage interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bent, John M.; Faibish, Sorin; Ting, Dennis P. J.

    A key-value store is provided having one or more key-value storage interfaces. A key-value store on at least one compute node comprises a memory for storing a plurality of key-value pairs; and an abstract storage interface comprising a software interface module that communicates with at least one persistent storage device providing a key-value interface for persistent storage of one or more of the plurality of key-value pairs, wherein the software interface module provides the one or more key-value pairs to the at least one persistent storage device in a key-value format. The abstract storage interface optionally processes one or moremore » batch operations on the plurality of key-value pairs. A distributed embodiment for a partitioned key-value store is also provided.« less

  3. Liver Rapid Reference Set Application ( #2): Lubman - Univ of Michigan (2010) — EDRN Public Portal

    Cancer.gov

    We are requesting the reference set, which includes 50 HCC cases and 50 cirrhotic controls. In our preliminary study, AFP had a AUROC of 0.66 while the AUROC for the 5 glycoproteins was 0.81. The sensitivity and specificity for the 5 glycoproteins was 79% and 72% at the point that maximizes sensitivity+specificity in the ROC curve, and it was 79% and 35%, respectively, for AFP at the same point in the ROC curve. The reference set will allow us to determine the best performance of the 5 glycoproteins by themselves or whether their combination has a better sensitivity and/or specificity and AUROC. While a direct comparison with AFP will be made, the reference set will not allow a robust comparison due to the low sample size. If the glycoproteins are complementary or have better performance than AFP, then the next step would be to test them in the entire phase 2 hepatocellular carcinoma set.

  4. SUPPLEMENTARY COMPARISON: Final report of the bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B between PTB and NIMT

    NASA Astrophysics Data System (ADS)

    Sanponpute, Tassanai; Meesaplak, Apichaya; Herrmann, Konrad; Menelao, Febo

    2009-01-01

    The bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B was arranged by the National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison was to confirm the calibration and measurement capabilities of NIMT in hardness measurement. The period of measurement covered March to August 2009. There were two sets of artefacts: scale A artefact set and scale B artefact set. The scale A artefact set consisted of seven hardness blocks: 35 HRA, 40 HRA, 55 HRA, 60 HRA, 70 HRA, 80 HRA, 85 HRA. The artefact set for scale B consisted of nine hardness blocks: 25 HRB, 30 HRB, 40 HRB, 50 HRB, 60 HRB, 70 HRB, 80 HRB, 90 HRB, 100 HRB. Laboratories had to ensure that the primary Rockwell hardness machines passed the verification process according to ISO 6508-3. Then participants measured the hardness value by making ten indentations in a designated area of each artefact block. Hardness measurement results and uncertainty budget were then reported to the pilot laboratory and were used to compute the degrees of equivalence in terms of the Comparison Reference Value (CRV) and En ratio. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. Translating Genius: The Importance Of The Relationship Between Military Geniuses And A Key - Subordinate

    DTIC Science & Technology

    2014-04-01

    reference to both the subjects of the research (who are all men ) and in reference to hypothetical, generic genius to key- subordinate relationships. These... men who so dominated the battlefield that they have come to be archetypes of personality and to even define entire ages of warfare. Brash, aggressive...great men , and their light burns so bright that their vision and will is single-handedly imposed upon their enemies? Or is there something more

  6. Keys and seats: Spatial response coding underlying the joint spatial compatibility effect.

    PubMed

    Dittrich, Kerstin; Dolk, Thomas; Rothe-Wulf, Annelie; Klauer, Karl Christoph; Prinz, Wolfgang

    2013-11-01

    Spatial compatibility effects (SCEs) are typically observed when participants have to execute spatially defined responses to nonspatial stimulus features (e.g., the color red or green) that randomly appear to the left and the right. Whereas a spatial correspondence of stimulus and response features facilitates response execution, a noncorrespondence impairs task performance. Interestingly, the SCE is drastically reduced when a single participant responds to one stimulus feature (e.g., green) by operating only one response key (individual go/no-go task), whereas a full-blown SCE is observed when the task is distributed between two participants (joint go/no-go task). This joint SCE (a.k.a. the social Simon effect) has previously been explained by action/task co-representation, whereas alternative accounts ascribe joint SCEs to spatial components inherent in joint go/no-go tasks that allow participants to code their responses spatially. Although increasing evidence supports the idea that spatial rather than social aspects are responsible for joint SCEs emerging, it is still unclear to which component(s) the spatial coding refers to: the spatial orientation of response keys, the spatial orientation of responding agents, or both. By varying the spatial orientation of the responding agents (Exp. 1) and of the response keys (Exp. 2), independent of the spatial orientation of the stimuli, in the present study we found joint SCEs only when both the seating and the response key alignment matched the stimulus alignment. These results provide evidence that spatial response coding refers not only to the response key arrangement, but also to the-often neglected-spatial orientation of the responding agents.

  7. Decoy-state reference-frame-independent quantum key distribution with both source errors and statistical fluctuations

    NASA Astrophysics Data System (ADS)

    Liu, Kang; Li, Jian; Zhu, Jian-Rong; Zhang, Chun-Mei; Wang, Qin

    2017-12-01

    Not Available Project supported by the National Key Research and Development Program of China (Grant No. 2017YFA0304100), the National Natural Science Foundation of China (Grant Nos. 61475197, 61590932, 11774180, and 61705110), the Natural Science Foundation of the Jiangsu Higher Education Institutions (Grant Nos. 15KJA120002 and 17KJB140016), the Outstanding Youth Project of Jiangsu Province, China (Grant No. BK20150039), the Natural Science Foundation of Jiangsu Province, China (Grant No. BK20170902), and the Science Fund from the Nanjing University of Posts and Telecommunications, China (Grant No. NY217006).

  8. Quantifying the climate effects of bioenergy – Choice of reference system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koponen, Kati; Soimakallio, Sampo; Kline, Keith L.

    In order to understand the climate effects of a bioenergy system, a comparison between the bioenergy system and a reference system is required. The reference system describes the situation that occurs in the absence of the bioenergy system with respect to the use of land, energy, and materials. The importance of reference systems is discussed in the literature but guidance on choosing suitable reference systems for assessing climate effects of bioenergy is limited. The reference system should align with the purpose of the study. Transparency of reference system assumptions is essential for proper interpretation of bioenergy assessments. This paper presentsmore » guidance for selecting suitable reference systems. Particular attention is given to choosing the land reference. If the goal is to study the climate effects of bioenergy as a part of total anthropogenic activity the reference system should illustrate what is expected in the absence of human activities. In such a case the suitable land reference is natural regeneration, and energy or material reference systems are not relevant. If the goal is to assess the effect of a change in bioenergy use, the reference system should incorporate human activities. In this case suitable reference systems describe the most likely alternative uses of the land, energy and materials in the absence of the change in bioenergy use. The definition of the reference system is furthermore subject to the temporal scope of the study. In practice, selecting and characterizing reference systems will involve various choices and uncertainties which should be considered carefully. As a result, it can be instructive to consider how alternative reference systems influence the results and conclusions drawn from bioenergy assessments.« less

  9. Quantifying the climate effects of bioenergy – Choice of reference system

    DOE PAGES

    Koponen, Kati; Soimakallio, Sampo; Kline, Keith L.; ...

    2017-06-27

    In order to understand the climate effects of a bioenergy system, a comparison between the bioenergy system and a reference system is required. The reference system describes the situation that occurs in the absence of the bioenergy system with respect to the use of land, energy, and materials. The importance of reference systems is discussed in the literature but guidance on choosing suitable reference systems for assessing climate effects of bioenergy is limited. The reference system should align with the purpose of the study. Transparency of reference system assumptions is essential for proper interpretation of bioenergy assessments. This paper presentsmore » guidance for selecting suitable reference systems. Particular attention is given to choosing the land reference. If the goal is to study the climate effects of bioenergy as a part of total anthropogenic activity the reference system should illustrate what is expected in the absence of human activities. In such a case the suitable land reference is natural regeneration, and energy or material reference systems are not relevant. If the goal is to assess the effect of a change in bioenergy use, the reference system should incorporate human activities. In this case suitable reference systems describe the most likely alternative uses of the land, energy and materials in the absence of the change in bioenergy use. The definition of the reference system is furthermore subject to the temporal scope of the study. In practice, selecting and characterizing reference systems will involve various choices and uncertainties which should be considered carefully. As a result, it can be instructive to consider how alternative reference systems influence the results and conclusions drawn from bioenergy assessments.« less

  10. Two Low Coverage Bird Genomes and a Comparison of Reference-Guided versus De Novo Genome Assemblies

    PubMed Central

    Card, Daren C.; Schield, Drew R.; Reyes-Velasco, Jacobo; Fujita, Matthew K.; Andrew, Audra L.; Oyler-McCance, Sara J.; Fike, Jennifer A.; Tomback, Diana F.; Ruggiero, Robert P.; Castoe, Todd A.

    2014-01-01

    As a greater number and diversity of high-quality vertebrate reference genomes become available, it is increasingly feasible to use these references to guide new draft assemblies for related species. Reference-guided assembly approaches may substantially increase the contiguity and completeness of a new genome using only low levels of genome coverage that might otherwise be insufficient for de novo genome assembly. We used low-coverage (∼3.5–5.5x) Illumina paired-end sequencing to assemble draft genomes of two bird species (the Gunnison Sage-Grouse, Centrocercus minimus, and the Clark's Nutcracker, Nucifraga columbiana). We used these data to estimate de novo genome assemblies and reference-guided assemblies, and compared the information content and completeness of these assemblies by comparing CEGMA gene set representation, repeat element content, simple sequence repeat content, and GC isochore structure among assemblies. Our results demonstrate that even lower-coverage genome sequencing projects are capable of producing informative and useful genomic resources, particularly through the use of reference-guided assemblies. PMID:25192061

  11. Differences in muscle activity during hand-dexterity tasks between women with arthritis and a healthy reference group.

    PubMed

    Brorsson, Sofia; Nilsdotter, Anna; Thorstensson, Carina; Bremander, Ann

    2014-05-15

    Impaired hand function is common in patients with arthritis and it affects performance of daily activities; thus, hand exercises are recommended. There is little information on the extent to which the disease affects activation of the flexor and extensor muscles during these hand-dexterity tasks. The purpose of this study was to compare muscle activation during such tasks in subjects with arthritis and in a healthy reference group. Muscle activation was measured in m. extensor digitorium communis (EDC) and in m. flexor carpi radialis (FCR) with surface electromyography (EMG) in women with rheumatoid arthritis (RA, n = 20), hand osteoarthritis (HOA, n = 16) and in a healthy reference group (n = 20) during the performance of four daily activity tasks and four hand exercises. Maximal voluntary isometric contraction (MVIC) was measured to enable intermuscular comparisons, and muscle activation is presented as %MVIC. The arthritis group used a higher %MVIC than the reference group in both FCR and EDC when cutting with a pair of scissors, pulling up a zipper and-for the EDC-also when writing with a pen and using a key (p < 0.02). The exercise "rolling dough with flat hands" required the lowest %MVIC and may be less effective in improving muscle strength. Women with arthritis tend to use higher levels of muscle activation in daily tasks than healthy women, and wrist extensors and flexors appear to be equally affected. It is important that hand training programs reflect real-life situations and focus also on extensor strength.

  12. Woodstove smoke and CO emissions: comparison of reference methods with the VIP sampler.

    PubMed

    Jaasma, D R; Champion, M C; Shelton, J W

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO2 concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six different woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.

  13. [Geographical distribution of the Serum creatinine reference values of healthy adults].

    PubMed

    Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng

    2016-11-20

    To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.

  14. Comparison of Pyranometers and Reference Cells on Fixed and One-Axis Tracking Surfaces: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooraghi, Michael R; Sengupta, Manajit; Vignola, Frank

    A wide variety of sensors are used to monitor the irradiance incident on solar modules to evaluate the performance of photovoltaic (PV) systems. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules, a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface,more » a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles of incidence, even though both instruments are based on measuring the short-circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded-base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer, which has a response nearly independent of the wavelength of light used by PV modules.« less

  15. Locating and parsing bibliographic references in HTML medical articles

    PubMed Central

    Zou, Jie; Le, Daniel; Thoma, George R.

    2010-01-01

    The set of references that typically appear toward the end of journal articles is sometimes, though not always, a field in bibliographic (citation) databases. But even if references do not constitute such a field, they can be useful as a preprocessing step in the automated extraction of other bibliographic data from articles, as well as in computer-assisted indexing of articles. Automation in data extraction and indexing to minimize human labor is key to the affordable creation and maintenance of large bibliographic databases. Extracting the components of references, such as author names, article title, journal name, publication date and other entities, is therefore a valuable and sometimes necessary task. This paper describes a two-step process using statistical machine learning algorithms, to first locate the references in HTML medical articles and then to parse them. Reference locating identifies the reference section in an article and then decomposes it into individual references. We formulate this step as a two-class classification problem based on text and geometric features. An evaluation conducted on 500 articles drawn from 100 medical journals achieves near-perfect precision and recall rates for locating references. Reference parsing identifies the components of each reference. For this second step, we implement and compare two algorithms. One relies on sequence statistics and trains a Conditional Random Field. The other focuses on local feature statistics and trains a Support Vector Machine to classify each individual word, followed by a search algorithm that systematically corrects low confidence labels if the label sequence violates a set of predefined rules. The overall performance of these two reference-parsing algorithms is about the same: above 99% accuracy at the word level, and over 97% accuracy at the chunk level. PMID:20640222

  16. Locating and parsing bibliographic references in HTML medical articles.

    PubMed

    Zou, Jie; Le, Daniel; Thoma, George R

    2010-06-01

    The set of references that typically appear toward the end of journal articles is sometimes, though not always, a field in bibliographic (citation) databases. But even if references do not constitute such a field, they can be useful as a preprocessing step in the automated extraction of other bibliographic data from articles, as well as in computer-assisted indexing of articles. Automation in data extraction and indexing to minimize human labor is key to the affordable creation and maintenance of large bibliographic databases. Extracting the components of references, such as author names, article title, journal name, publication date and other entities, is therefore a valuable and sometimes necessary task. This paper describes a two-step process using statistical machine learning algorithms, to first locate the references in HTML medical articles and then to parse them. Reference locating identifies the reference section in an article and then decomposes it into individual references. We formulate this step as a two-class classification problem based on text and geometric features. An evaluation conducted on 500 articles drawn from 100 medical journals achieves near-perfect precision and recall rates for locating references. Reference parsing identifies the components of each reference. For this second step, we implement and compare two algorithms. One relies on sequence statistics and trains a Conditional Random Field. The other focuses on local feature statistics and trains a Support Vector Machine to classify each individual word, followed by a search algorithm that systematically corrects low confidence labels if the label sequence violates a set of predefined rules. The overall performance of these two reference-parsing algorithms is about the same: above 99% accuracy at the word level, and over 97% accuracy at the chunk level.

  17. A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry.

    PubMed

    Yan, Ying; Han, Bingqing; Zeng, Jie; Zhou, Weiyan; Zhang, Tianjiao; Zhang, Jiangtao; Chen, Wenxiang; Zhang, Chuanbao

    2017-08-28

    Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. An inductively coupled plasma mass spectrometry (ICP-MS) method was developed. Serum samples were gravimetrically spiked with an aluminum internal standard, digested with 69% ultrapure nitric acid, and diluted to the required concentration. The 39K/27Al ratios were measured by ICP-MS in hydrogen mode. The method was calibrated using 5% nitric acid matrix calibrators, and the calibration function was established using the bracketing method. The correlation coefficients between the measured 39K/27Al ratios and the analyte concentration ratios were >0.9999. The coefficients of variation were 0.40%, 0.68%, and 0.22% for the three serum samples, and the analytical recovery was 99.8%. The accuracy of the measurement was also verified by measuring certified reference materials, SRM909b and SRM956b. Comparison with the ion selective electrode routine method and international inter-laboratory comparisons gave satisfied results. The new ICP-MS method is specific, precise, simple, and low-cost, and it may be used as a candidate reference method for standardizing serum potassium measurements.

  18. Effects of an Attachment-based Intervention on CPS-Referred Mothers’ Event-related Potentials to Children’s Emotions

    PubMed Central

    Bernard, Kristin; Simons, Robert; Dozier, Mary

    2015-01-01

    This study examined the neurobiology of maternal sensitivity to children’s emotions among mothers involved with Child Protective Services (CPS) and low-risk comparison mothers (Mean age = 31.6 years). CPS-referred mothers participated in the Attachment and Biobehavioral Catch-up (ABC) intervention or a control intervention. Mothers’ event-related potentials (ERP) were measured while they categorized images of children with crying, laughing, and neutral expressions. CPS-referred ABC mothers (n = 19) and low-risk comparison mothers (n = 30) showed a larger enhancement of ERP responses for emotional faces relative to neutral faces than CPS-referred control mothers (n = 21). Additionally, the magnitude of ERP responses to emotional faces was associated with observed maternal sensitivity. Findings add to our understanding of the neurobiology of deficits in parenting and suggest that these deficits are changeable through a parenting intervention. PMID:26344398

  19. 30 CFR 206.176 - How do I perform accounting for comparison?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I perform accounting for comparison? 206... REVENUE MANAGEMENT PRODUCT VALUATION Indian Gas § 206.176 How do I perform accounting for comparison? (a... requires accounting for comparison (also referred to as actual dual accounting). Except as provided in...

  20. Establishing International Blood Pressure References Among Nonoverweight Children and Adolescents Aged 6 to 17 Years.

    PubMed

    Xi, Bo; Zong, Xin'nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y T; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Romdhane, Habiba Ben; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; El Ati, Jalila; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao

    2016-01-26

    Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States). Data on BP for 52 636 nonoverweight children and adolescents aged 6 to 19 years were obtained from 7 large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and the United States. BP values were obtained with certified mercury sphygmomanometers in all 7 countries by using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th, and 99th) by age and height were estimated by using the Generalized Additive Model for Location Scale and Shape model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. In comparison with the BP levels of the 90th and 95th percentiles of the US Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower, whereas diastolic BP was similar. These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help to identify hypertensive youths in diverse populations. © 2015 American Heart Association, Inc.

  1. Florida Keys

    NASA Image and Video Library

    2002-12-13

    The Florida Keys are a chain of islands, islets and reefs extending from Virginia Key to the Dry Tortugas for about 309 kilometers (192 miles). The keys are chiefly limestone and coral formations. The larger islands of the group are Key West (with its airport), Key Largo, Sugarloaf Key, and Boca Chica Key. A causeway extends from the mainland to Key West. This image was acquired on October 28, 2001, by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) on NASA's Terra satellite. With its 14 spectral bands from the visible to the thermal infrared wavelength region, and its high spatial resolution of 15 to 90 meters (about 50 to 300 feet), ASTER images Earth to map and monitor the changing surface of our planet. http://photojournal.jpl.nasa.gov/catalog/PIA03890

  2. The importance of reference materials in doping-control analysis.

    PubMed

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  3. When Students Doubt Their Teachers' Diagnostic Competence: Moderation in the Internal/External Frame of Reference Model

    ERIC Educational Resources Information Center

    Zimmermann, Friederike; Möller, Jens; Köller, Olaf

    2018-01-01

    The internal/external frame of reference model (I/E model) posits that individuals' achievement-related self-concepts are formed through social comparisons (e.g., self vs. peers) within academic domains and dimensional comparisons (e.g., math vs. verbal) between distinct domains. A large body of research has supported the theorized pattern of…

  4. A free-access online key to identify Amazonian ferns.

    PubMed

    Zuquim, Gabriela; Tuomisto, Hanna; Prado, Jefferson

    2017-01-01

    There is urgent need for more data on species distributions in order to improve conservation planning. A crucial but challenging aspect of producing high-quality data is the correct identification of organisms. Traditional printed floras and dichotomous keys are difficult to use for someone not familiar with the technical jargon. In poorly known areas, such as Amazonia, they also become quickly outdated as new species are described or ranges extended. Recently, online tools have allowed developing dynamic, interactive, and accessible keys that make species identification possible for a broader public. In order to facilitate identifying plants collected in field inventories, we developed an internet-based free-access tool to identify Amazonian fern species. We focused on ferns, because they are easy to collect and their edaphic affinities are relatively well known, so they can be used as an indicator group for habitat mapping. Our key includes 302 terrestrial and aquatic entities mainly from lowland Amazonian forests. It is a free-access key, so the user can freely choose which morphological features to use and in which order to assess them. All taxa are richly illustrated, so specimens can be identified by a combination of character choices, visual comparison, and written descriptions. The identification tool was developed in Lucid 3.5 software and it is available at http://keyserver.lucidcentral.org:8080/sandbox/keys.jsp.

  5. A free-access online key to identify Amazonian ferns

    PubMed Central

    Zuquim, Gabriela; Tuomisto, Hanna; Prado, Jefferson

    2017-01-01

    Abstract There is urgent need for more data on species distributions in order to improve conservation planning. A crucial but challenging aspect of producing high-quality data is the correct identification of organisms. Traditional printed floras and dichotomous keys are difficult to use for someone not familiar with the technical jargon. In poorly known areas, such as Amazonia, they also become quickly outdated as new species are described or ranges extended. Recently, online tools have allowed developing dynamic, interactive, and accessible keys that make species identification possible for a broader public. In order to facilitate identifying plants collected in field inventories, we developed an internet-based free-access tool to identify Amazonian fern species. We focused on ferns, because they are easy to collect and their edaphic affinities are relatively well known, so they can be used as an indicator group for habitat mapping. Our key includes 302 terrestrial and aquatic entities mainly from lowland Amazonian forests. It is a free-access key, so the user can freely choose which morphological features to use and in which order to assess them. All taxa are richly illustrated, so specimens can be identified by a combination of character choices, visual comparison, and written descriptions. The identification tool was developed in Lucid 3.5 software and it is available at http://keyserver.lucidcentral.org:8080/sandbox/keys.jsp. PMID:28781548

  6. Scoring Coreference Partitions of Predicted Mentions: A Reference Implementation.

    PubMed

    Pradhan, Sameer; Luo, Xiaoqiang; Recasens, Marta; Hovy, Eduard; Ng, Vincent; Strube, Michael

    2014-06-01

    The definitions of two coreference scoring metrics- B 3 and CEAF-are underspecified with respect to predicted , as opposed to key (or gold ) mentions. Several variations have been proposed that manipulate either, or both, the key and predicted mentions in order to get a one-to-one mapping. On the other hand, the metric BLANC was, until recently, limited to scoring partitions of key mentions. In this paper, we (i) argue that mention manipulation for scoring predicted mentions is unnecessary, and potentially harmful as it could produce unintuitive results; (ii) illustrate the application of all these measures to scoring predicted mentions; (iii) make available an open-source, thoroughly-tested reference implementation of the main coreference evaluation measures; and (iv) rescore the results of the CoNLL-2011/2012 shared task systems with this implementation. This will help the community accurately measure and compare new end-to-end coreference resolution algorithms.

  7. Woodstove smoke and CO emissions: Comparison of reference methods with the VIP sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaasma, D.R.; Champion, M.C.; Shelton, J.W.

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO{sub 2} concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six differentmore » woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.« less

  8. Quality assurance of reference standards from nine European solar-ultraviolet monitoring laboratories.

    PubMed

    Gröbner, Julian; Rembges, Diana; Bais, Alkiviadis F; Blumthaler, Mario; Cabot, Thierry; Josefsson, Weine; Koskela, Tapani; Thorseth, Trond M; Webb, Ann R; Wester, Ulf

    2002-07-20

    A program for quality assurance of reference standards has been initiated among nine solar-UV monitoring laboratories. By means of a traveling lamp package that comprises several 1000-W ANSI code DXW-type quartz-halogen lamps, a 0.1-ohm shunt, and a 6-1/2 digit voltmeter, the irradiance scales used by the nine laboratories were compared with one another; a relative uncertainty of 1.2% was found. The comparison of 15 reference standards yielded differences of as much as 9%; the average difference was less than 3%.

  9. [Comparison between references of the overweight and obesity prevalence, through the Body Mass Index, in Argentinean children].

    PubMed

    Padula, Gisel; Salceda, Susana A

    2008-12-01

    The evaluation of child nutritional status is highly dependent on the growth charts used. The aim of this study was to compare different references assessing overweight and obesity in children population, through the Body Mass Index. A total of 737 healthy children born at term, aged 2-5 years, were included (cross-sectional study). The participation was voluntary and consent. Body Mass Index (kg/m2) was estimated. The measurements techniques were based on national guidelines. We compared three references: (1) Centers for Disease Control and Prevention (CDC) (> Pc85: overweight; > Pc95: obesity; (2) International Obesity Task Force (IOTF) (sex-age-specific body mass index cut-offs); (3) World Health Organization (WHO) (+2 standard deviation: overweight; +3: obesity). The Epi Info 6.0 software was used to the statistical evaluation (chi2, p < or = .05%). The prevalence of overweight was 1.1 and 2.33 times higher in CDC application respect to the IOTF and the WHO references respectively. The prevalence of overweight was 2.1 times higher in IOTF application respect to the WHO references (p = .00001). The prevalence of obesity was 5.4 and 23.9 times higher in CDC application respect to the IOTF and the WHO references respectively. The prevalence of obesity was 4.4 times higher in IOTF application respect to the WHO references (p = .0000001). The prevalence of overweight and obesity, calculated through the BMI, differs substantially according to the reference and cut-off points used. In the absence of even a single criterion, each of the references should be used with care.

  10. LipidQC: Method Validation Tool for Visual Comparison to SRM 1950 Using NIST Interlaboratory Comparison Exercise Lipid Consensus Mean Estimate Values.

    PubMed

    Ulmer, Candice Z; Ragland, Jared M; Koelmel, Jeremy P; Heckert, Alan; Jones, Christina M; Garrett, Timothy J; Yost, Richard A; Bowden, John A

    2017-12-19

    As advances in analytical separation techniques, mass spectrometry instrumentation, and data processing platforms continue to spur growth in the lipidomics field, more structurally unique lipid species are detected and annotated. The lipidomics community is in need of benchmark reference values to assess the validity of various lipidomics workflows in providing accurate quantitative measurements across the diverse lipidome. LipidQC addresses the harmonization challenge in lipid quantitation by providing a semiautomated process, independent of analytical platform, for visual comparison of experimental results of National Institute of Standards and Technology Standard Reference Material (SRM) 1950, "Metabolites in Frozen Human Plasma", against benchmark consensus mean concentrations derived from the NIST Lipidomics Interlaboratory Comparison Exercise.

  11. Discrimination of human and nonhuman blood using Raman spectroscopy with self-reference algorithm

    NASA Astrophysics Data System (ADS)

    Bian, Haiyi; Wang, Peng; Wang, Jun; Yin, Huancai; Tian, Yubing; Bai, Pengli; Wu, Xiaodong; Wang, Ning; Tang, Yuguo; Gao, Jing

    2017-09-01

    We report a self-reference algorithm to discriminate human and nonhuman blood by calculating the ratios of identification Raman peaks to reference Raman peaks and choosing appropriate threshold values. The influence of using different reference peaks and identification peaks was analyzed in detail. The Raman peak at 1003 cm-1 was proved to be a stable reference peak to avoid the influencing factors, such as the incident laser intensity and the amount of sample. The Raman peak at 1341 cm-1 was found to be an efficient identification peak, which indicates that the difference between human and nonhuman blood results from the C-H bend in tryptophan. The comparison between self-reference algorithm and partial least square method was made. It was found that the self-reference algorithm not only obtained the discrimination results with the same accuracy, but also provided information on the difference of chemical composition. In addition, the performance of self-reference algorithm whose true positive rate is 100% is significant for customs inspection to avoid genetic disclosure and forensic science.

  12. Computational clustering for viral reference proteomes

    PubMed Central

    Chen, Chuming; Huang, Hongzhan; Mazumder, Raja; Natale, Darren A.; McGarvey, Peter B.; Zhang, Jian; Polson, Shawn W.; Wang, Yuqi; Wu, Cathy H.

    2016-01-01

    Motivation: The enormous number of redundant sequenced genomes has hindered efforts to analyze and functionally annotate proteins. As the taxonomy of viruses is not uniformly defined, viral proteomes pose special challenges in this regard. Grouping viruses based on the similarity of their proteins at proteome scale can normalize against potential taxonomic nomenclature anomalies. Results: We present Viral Reference Proteomes (Viral RPs), which are computed from complete virus proteomes within UniProtKB. Viral RPs based on 95, 75, 55, 35 and 15% co-membership in proteome similarity based clusters are provided. Comparison of our computational Viral RPs with UniProt’s curator-selected Reference Proteomes indicates that the two sets are consistent and complementary. Furthermore, each Viral RP represents a cluster of virus proteomes that was consistent with virus or host taxonomy. We provide BLASTP search and FTP download of Viral RP protein sequences, and a browser to facilitate the visualization of Viral RPs. Availability and implementation: http://proteininformationresource.org/rps/viruses/ Contact: chenc@udel.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27153712

  13. Inferring product healthfulness from nutrition labelling. The influence of reference points.

    PubMed

    van Herpen, Erica; Hieke, Sophie; van Trijp, Hans C M

    2014-01-01

    Despite considerable research on nutrition labelling, it has proven difficult to find a front-of-pack label which is informative about product healthfulness across various situations. This study examines the ability of different types of nutrition labelling schemes (multiple traffic light label, nutrition table, GDA, logo) to communicate product healthfulness (a) across different product categories, (b) between options from the same product category, and (c) when viewed in isolation and in comparison with another product. Results of two experiments in Germany and The Netherlands show that a labelling scheme with reference point information at the nutrient level (e.g., the traffic light label) can achieve all three objectives. Although other types of labelling schemes are also capable of communicating healthfulness, labelling schemes lacking reference point information (e.g., nutrition tables) are less effective when no comparison product is available, and labelling schemes based on overall product healthfulness within the category (e.g., logos) can diminish consumers' ability to differentiate between categories, leading to a potential misinterpretation of product healthfulness. None of the labels affected food preferences.

  14. Inferring Product Healthfulness from Nutrition Labelling: The Influence of Reference Points.

    PubMed

    Herpen, Erica van; Hieke, Sophie; van Trijp, Hans C M

    2013-10-25

    Despite considerable research on nutrition labelling, it has proven difficult to find a front-of-pack label which is informative about product healthfulness across various situations. This study examines the ability of different types of nutrition labelling schemes (multiple traffic light label, nutrition table, GDA, logo) to communicate product healthfulness (a) across different product categories, (b) between options from the same product category, and (c) when viewed in isolation and in comparison with another product. Results of two experiments in Germany and The Netherlands show that a labelling scheme with reference point information at the nutrient level (e.g., the traffic light label) can achieve all three objectives. Although other types of labelling schemes are also capable of communicating healthfulness, labelling schemes lacking reference point information (e.g., nutrition tables) are less effective when no comparison product is available, and labelling schemes based on overall product healthfulness within the category (e.g., logos) can diminish consumers' ability to differentiate between categories, leading to a potential misinterpretation of product healthfulness. None of the labels affected food preferences. Copyright © 2013. Published by Elsevier Ltd.

  15. Final report on regional supplementary comparison SIM.M.FF-S5: Volume of liquids at 50 mL

    NASA Astrophysics Data System (ADS)

    Morales, Abed; Malta, Dalni; Kornblit, Fernando; Ramírez, Ruben R.; Arias, Roberto; Trujillo, Sonia

    2012-01-01

    A regional supplementary comparison for the volume of liquid at 50 mL was conducted during October 2009 to June 2010 between the SIM members CENAM, INTI, INMETRO, INDECOPI and INTN. The transfer standard consisted of two 50 mL glass pycnometers, of the Gay Lussac type. CENAM acted as the pilot, collected the measurement results, analyzed the data and produced the comparison report. The median of all participants' results was used to calculate the regional comparison reference value because the result for one of the two pycnometers in one laboratory failed the chi-squared test at the 0.05 probability level. The measurements reported by the participants show an excellent overlap in four out of the five NMIs (-34×10-6 < Di < 29×10-6). The degree of equivalence obtained herein will be taken into account for the preparation of calibration and measurement capabilities claims from the participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Learning to Learn in the European Reference Framework for Lifelong Learning

    ERIC Educational Resources Information Center

    Pirrie, Anne; Thoutenhoofd, Ernst D.

    2013-01-01

    This article explores the construction of learning to learn that is implicit in the document "Key Competences for Lifelong Learning--European Reference Framework" and related education policy from the European Commission. The authors argue that the hallmark of learning to learn is the development of a fluid sociality rather than the…

  17. New reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.

    1993-01-01

    Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.

  18. A digital reference collection for aquatic macroinvertebrates of North America

    USGS Publications Warehouse

    Walters, David; Ford, Morgan A; Zuellig, Robert E.

    2017-01-01

    Aquatic invertebrates are a key component of freshwater ecosystems, and understanding aquatic invertebrate taxonomy is a cornerstone of freshwater science. Physical reference collections of expertly identified voucher specimens are the ‘gold-standard’ used to confirm specimen identifications. However, most biologists lack access to such collections, which themselves tend to be highly regionalized and somewhat limited in terms of taxonomic scope. The North American Aquatic Macroinvertebrate Digital Reference Collection (NAAMDRC; https://sciencebase.usgs.gov/naamdrc) was developed by the US Geological Survey (USGS) to overcome these limitations of physical collections. NAAMDRC provides users with public-domain, high-quality digital photographs to help verify specimen identifications.

  19. Methodological problems in the use of indirect comparisons for evaluating healthcare interventions: survey of published systematic reviews.

    PubMed

    Song, Fujian; Loke, Yoon K; Walsh, Tanya; Glenny, Anne-Marie; Eastwood, Alison J; Altman, Douglas G

    2009-04-03

    To investigate basic assumptions and other methodological problems in the application of indirect comparison in systematic reviews of competing healthcare interventions. Survey of published systematic reviews. Inclusion criteria Systematic reviews published between 2000 and 2007 in which an indirect approach had been explicitly used. Identified reviews were assessed for comprehensiveness of the literature search, method for indirect comparison, and whether assumptions about similarity and consistency were explicitly mentioned. The survey included 88 review reports. In 13 reviews, indirect comparison was informal. Results from different trials were naively compared without using a common control in six reviews. Adjusted indirect comparison was usually done using classic frequentist methods (n=49) or more complex methods (n=18). The key assumption of trial similarity was explicitly mentioned in only 40 of the 88 reviews. The consistency assumption was not explicit in most cases where direct and indirect evidence were compared or combined (18/30). Evidence from head to head comparison trials was not systematically searched for or not included in nine cases. Identified methodological problems were an unclear understanding of underlying assumptions, inappropriate search and selection of relevant trials, use of inappropriate or flawed methods, lack of objective and validated methods to assess or improve trial similarity, and inadequate comparison or inappropriate combination of direct and indirect evidence. Adequate understanding of basic assumptions underlying indirect and mixed treatment comparison is crucial to resolve these methodological problems. APPENDIX 1: PubMed search strategy. APPENDIX 2: Characteristics of identified reports. APPENDIX 3: Identified studies. References of included studies.

  20. Comparison of lysimeter based and calculated ASCE reference evapotranspiration in a subhumid climate

    NASA Astrophysics Data System (ADS)

    Nolz, Reinhard; Cepuder, Peter; Eitzinger, Josef

    2016-04-01

    The standardized form of the well-known FAO Penman-Monteith equation, published by the Environmental and Water Resources Institute of the American Society of Civil Engineers (ASCE-EWRI), is recommended as a standard procedure for calculating reference evapotranspiration (ET ref) and subsequently plant water requirements. Applied and validated under different climatic conditions it generally achieved good results compared to other methods. However, several studies documented deviations between measured and calculated reference evapotranspiration depending on environmental and weather conditions. Therefore, it seems generally advisable to evaluate the model under local environmental conditions. In this study, reference evapotranspiration was determined at a subhumid site in northeastern Austria from 2005 to 2010 using a large weighing lysimeter (ET lys). The measured data were compared with ET ref calculations. Daily values differed slightly during a year, at which ET ref was generally overestimated at small values, whereas it was rather underestimated when ET was large, which is supported also by other studies. In our case, advection of sensible heat proved to have an impact, but it could not explain the differences exclusively. Obviously, there were also other influences, such as seasonal varying surface resistance or albedo. Generally, the ASCE-EWRI equation for daily time steps performed best at average weather conditions. The outcomes should help to correctly interpret ET ref data in the region and in similar environments and improve knowledge on the dynamics of influencing factors causing deviations.

  1. Liver Rapid Reference Set Application (#1): David Lubman - Univ of Michigan (2009) — EDRN Public Portal

    Cancer.gov

    We are requesting the reference set, which includes 50 HCC cases and 50 cirrhotic controls. In our preliminary study, AFP had a AUROC of 0.66 while the AUROC for the 5 glycoproteins was 0.81. The sensitivity and specificity for the 5 glycoproteins was 79% and 72% at the point that maximizes sensitivity+specificity in the ROC curve, and it was 79% and 35%, respectively, for AFP at the same point in the ROC curve. The reference set will allow us to determine the best performance of the 5 glycoproteins by themselves or whether their combination has a better sensitivity and/or specificity and AUROC. While a direct comparison with AFP will be made, the reference set will not allow a robust comparison due to the low sample size. If the glycoproteins are complementary or have better performance than AFP, then the next step would be to test them in the entire phase 2 hepatocellular carcinoma set.

  2. Function key and shortcut key use in airway facilities.

    DOT National Transportation Integrated Search

    2003-02-01

    This document provides information on the function keys and shortcut keys used by systems in the Federal Aviation Administration : Airway Facilities (AF) work environment. It includes a catalog of the function keys and shortcut keys used by each syst...

  3. No-reference image quality assessment for horizontal-path imaging scenarios

    NASA Astrophysics Data System (ADS)

    Rios, Carlos; Gladysz, Szymon

    2013-05-01

    There exist several image-enhancement algorithms and tasks associated with imaging through turbulence that depend on defining the quality of an image. Examples include: "lucky imaging", choosing the width of the inverse filter for image reconstruction, or stopping iterative deconvolution. We collected a number of image quality metrics found in the literature. Particularly interesting are the blind, "no-reference" metrics. We discuss ways of evaluating the usefulness of these metrics, even when a fully objective comparison is impossible because of the lack of a reference image. Metrics are tested on simulated and real data. Field data comes from experiments performed by the NATO SET 165 research group over a 7 km distance in Dayton, Ohio.

  4. Process-based reference conditions: An alternative approach for managed river systems

    NASA Astrophysics Data System (ADS)

    Grams, P.; Melis, T.; Wright, S.; Schmidt, J.; Topping, D.

    2008-12-01

    Physical reference conditions, whether based on historic information or the condition of nearby less impaired systems, provide necessary information that contributes to an assessment of stream condition and the nature of channel transformation. In many cases, however, the utility of this traditional 'reference' approach may end at the assessment stage and not be applicable to establishing and implementing restoration goals. Ongoing impacts such as continued existence of an upstream dam or the persistence of invasive vegetation may render restoration based on a physical reference infeasible. In these circumstances, an alternative approach is to identify and describe reference processes in place of physical reference conditions. This is the case for the Colorado River where large dams, a commitment to hydropower production, and legal mandates for regional distribution and off- channel consumption of water greatly reduce the relevance of historical conditions in setting goals for rehabilitation. In this setting, two strategies are available for setting reference conditions. One is maintenance of post-dam sediment mass balance, which attempts to ensure that the channel does not continue to degrade or aggrade and that riverine habitats do not continue to diverge from their historical condition. Post- dam sediment mass balance can be quantified at a reconnaissance or project scale. The second strategy is to define key processes that maintain the native ecosystem. These processes may, or may not, be consistent with maintenance of sediment mass balance, but they may be key to rejuvenation of spawning and rearing habitats, maintenance of historical ranges of temperature and turbidity, maintenance of a sustainable food base for the native aquatic community, or maintaining other riverine resources. Both strategies require careful monitoring of processes (e.g. sediment flux), which may add considerably to the cost and complexity of a monitoring program. An additional challenge

  5. Electrophysiological Responses to Expectancy Violations in Semantic and Gambling Tasks: A Comparison of Different EEG Reference Approaches

    PubMed Central

    Li, Ya; Wang, Yongchun; Zhang, Baoqiang; Wang, Yonghui; Zhou, Xiaolin

    2018-01-01

    Dynamically evaluating the outcomes of our actions and thoughts is a fundamental cognitive ability. Given its excellent temporal resolution, the event-related potential (ERP) technology has been used to address this issue. The feedback-related negativity (FRN) component of ERPs has been studied intensively with the averaged linked mastoid reference method (LM). However, it is unknown whether FRN can be induced by an expectancy violation in an antonym relations context and whether LM is the most suitable reference approach. To address these issues, the current research directly compared the ERP components induced by expectancy violations in antonym expectation and gambling tasks with a within-subjects design and investigated the effect of the reference approach on the experimental effects. Specifically, we systematically compared the influence of the LM, reference electrode standardization technique (REST) and average reference (AVE) approaches on the amplitude, scalp distribution and magnitude of ERP effects as a function of expectancy violation type. The expectancy deviation in the antonym expectation task elicited an N400 effect that differed from the FRN effect induced in the gambling task; this difference was confirmed by all the three reference methods. Both the amplitudes of the ERP effects (N400 and FRN) and the magnitude as the expectancy violation increased were greater under the LM approach than those under the REST approach, followed by those under the AVE approach. Based on the statistical results, the electrode sites that showed the N400 and FRN effects critically depended on the reference method, and the results of the REST analysis were consistent with previous ERP studies. Combined with evidence from simulation studies, we suggest that REST is an optional reference method to be used in future ERP data analysis. PMID:29615858

  6. Comparison of Scores on Two Visual-Motor Tests for Children Referred for Learning or Adjustment Difficulties.

    ERIC Educational Resources Information Center

    DeMers, Stephen T.; And Others

    1981-01-01

    This study compared the performance of school-aged children referred for learning or adjustment difficulties on Beery's Developmental Test of Visual-Motor Integration and Koppitz's version of the Bender-Gestalt test. Results indicated that the tests are related but not equivalent when administered to referred populations. (Author/AL)

  7. Evaluating Remote Reference Service: A Practical Guide to Problems and Solutions

    ERIC Educational Resources Information Center

    Pomerantz, Jeffrey; Mon, Lorri; McClure, Charles R.

    2008-01-01

    This paper identifies key methodological issues affecting quality of data in the evaluation of remote reference services. Despite a growing number of studies in this area, no comprehensive effort has been made to identify potential problems and suggest solutions. The strategies proposed in this paper offer practical ways in which libraries can…

  8. 'Sportmotorische Bestandesaufnahme': criterion- vs. norm-based reference values of fitness tests for Swiss first grade children.

    PubMed

    Tomatis, Laura; Krebs, Andreas; Siegenthaler, Jessica; Murer, Kurt; de Bruin, Eling D

    2015-01-01

    Health is closely linked to physical activity and fitness. It is therefore important to monitor fitness in children. Although many reports on physical tests have been published, data comparison between studies is an issue. This study reports Swiss first grade norm values of fitness tests and compares these with criterion reference data. A total of 10,565 boys (7.18 ± 0.42 years) and 10,204 girls (7.14 ± 0.41 years) were tested for standing long jump, plate tapping, 20-m shuttle run, lateral jump and 20-m sprint. Average values for six-, seven- and eight-year-olds were analysed and reference curves for age were constructed. Z-values were generated for comparisons with criterion references reported in the literature. Results were better for all disciplines in seven-year-old first grade children compared to six-year-old children (p < 0.01). Eight-year-old children did not perform better compared to seven-year-old children in the sprint run (p = 0.11), standing long jump (p > 0.99) and shuttle run (p = 0.43), whereas they were better in all other disciplines compared to their younger peers. The average performance of boys was better than girls except for tapping at the age of 8 (p = 0.06). Differences in performance due to testing protocol and setting must be considered when test values from a first grade setting are compared to criterion-based benchmarks. In a classroom setting, younger children tended to have better results and older children tended to have worse outcomes when compared to their age group criterion reference values. Norm reference data are valid allowing comparison with other data generated by similar test protocols applied in a classroom setting.

  9. The zebrafish reference genome sequence and its relationship to the human genome.

    PubMed

    Howe, Kerstin; Clark, Matthew D; Torroja, Carlos F; Torrance, James; Berthelot, Camille; Muffato, Matthieu; Collins, John E; Humphray, Sean; McLaren, Karen; Matthews, Lucy; McLaren, Stuart; Sealy, Ian; Caccamo, Mario; Churcher, Carol; Scott, Carol; Barrett, Jeffrey C; Koch, Romke; Rauch, Gerd-Jörg; White, Simon; Chow, William; Kilian, Britt; Quintais, Leonor T; Guerra-Assunção, José A; Zhou, Yi; Gu, Yong; Yen, Jennifer; Vogel, Jan-Hinnerk; Eyre, Tina; Redmond, Seth; Banerjee, Ruby; Chi, Jianxiang; Fu, Beiyuan; Langley, Elizabeth; Maguire, Sean F; Laird, Gavin K; Lloyd, David; Kenyon, Emma; Donaldson, Sarah; Sehra, Harminder; Almeida-King, Jeff; Loveland, Jane; Trevanion, Stephen; Jones, Matt; Quail, Mike; Willey, Dave; Hunt, Adrienne; Burton, John; Sims, Sarah; McLay, Kirsten; Plumb, Bob; Davis, Joy; Clee, Chris; Oliver, Karen; Clark, Richard; Riddle, Clare; Elliot, David; Eliott, David; Threadgold, Glen; Harden, Glenn; Ware, Darren; Begum, Sharmin; Mortimore, Beverley; Mortimer, Beverly; Kerry, Giselle; Heath, Paul; Phillimore, Benjamin; Tracey, Alan; Corby, Nicole; Dunn, Matthew; Johnson, Christopher; Wood, Jonathan; Clark, Susan; Pelan, Sarah; Griffiths, Guy; Smith, Michelle; Glithero, Rebecca; Howden, Philip; Barker, Nicholas; Lloyd, Christine; Stevens, Christopher; Harley, Joanna; Holt, Karen; Panagiotidis, Georgios; Lovell, Jamieson; Beasley, Helen; Henderson, Carl; Gordon, Daria; Auger, Katherine; Wright, Deborah; Collins, Joanna; Raisen, Claire; Dyer, Lauren; Leung, Kenric; Robertson, Lauren; Ambridge, Kirsty; Leongamornlert, Daniel; McGuire, Sarah; Gilderthorp, Ruth; Griffiths, Coline; Manthravadi, Deepa; Nichol, Sarah; Barker, Gary; Whitehead, Siobhan; Kay, Michael; Brown, Jacqueline; Murnane, Clare; Gray, Emma; Humphries, Matthew; Sycamore, Neil; Barker, Darren; Saunders, David; Wallis, Justene; Babbage, Anne; Hammond, Sian; Mashreghi-Mohammadi, Maryam; Barr, Lucy; Martin, Sancha; Wray, Paul; Ellington, Andrew; Matthews, Nicholas; Ellwood, Matthew; Woodmansey, Rebecca; Clark, Graham; Cooper, James D; Cooper, James; Tromans, Anthony; Grafham, Darren; Skuce, Carl; Pandian, Richard; Andrews, Robert; Harrison, Elliot; Kimberley, Andrew; Garnett, Jane; Fosker, Nigel; Hall, Rebekah; Garner, Patrick; Kelly, Daniel; Bird, Christine; Palmer, Sophie; Gehring, Ines; Berger, Andrea; Dooley, Christopher M; Ersan-Ürün, Zübeyde; Eser, Cigdem; Geiger, Horst; Geisler, Maria; Karotki, Lena; Kirn, Anette; Konantz, Judith; Konantz, Martina; Oberländer, Martina; Rudolph-Geiger, Silke; Teucke, Mathias; Lanz, Christa; Raddatz, Günter; Osoegawa, Kazutoyo; Zhu, Baoli; Rapp, Amanda; Widaa, Sara; Langford, Cordelia; Yang, Fengtang; Schuster, Stephan C; Carter, Nigel P; Harrow, Jennifer; Ning, Zemin; Herrero, Javier; Searle, Steve M J; Enright, Anton; Geisler, Robert; Plasterk, Ronald H A; Lee, Charles; Westerfield, Monte; de Jong, Pieter J; Zon, Leonard I; Postlethwait, John H; Nüsslein-Volhard, Christiane; Hubbard, Tim J P; Roest Crollius, Hugues; Rogers, Jane; Stemple, Derek L

    2013-04-25

    Zebrafish have become a popular organism for the study of vertebrate gene function. The virtually transparent embryos of this species, and the ability to accelerate genetic studies by gene knockdown or overexpression, have led to the widespread use of zebrafish in the detailed investigation of vertebrate gene function and increasingly, the study of human genetic disease. However, for effective modelling of human genetic disease it is important to understand the extent to which zebrafish genes and gene structures are related to orthologous human genes. To examine this, we generated a high-quality sequence assembly of the zebrafish genome, made up of an overlapping set of completely sequenced large-insert clones that were ordered and oriented using a high-resolution high-density meiotic map. Detailed automatic and manual annotation provides evidence of more than 26,000 protein-coding genes, the largest gene set of any vertebrate so far sequenced. Comparison to the human reference genome shows that approximately 70% of human genes have at least one obvious zebrafish orthologue. In addition, the high quality of this genome assembly provides a clearer understanding of key genomic features such as a unique repeat content, a scarcity of pseudogenes, an enrichment of zebrafish-specific genes on chromosome 4 and chromosomal regions that influence sex determination.

  10. A universal reference sample derived from clone vector for improved detection of differential gene expression

    PubMed Central

    Khan, Rishi L; Gonye, Gregory E; Gao, Guang; Schwaber, James S

    2006-01-01

    Background Using microarrays by co-hybridizing two samples labeled with different dyes enables differential gene expression measurements and comparisons across slides while controlling for within-slide variability. Typically one dye produces weaker signal intensities than the other often causing signals to be undetectable. In addition, undetectable spots represent a large problem for two-color microarray designs and most arrays contain at least 40% undetectable spots even when labeled with reference samples such as Stratagene's Universal Reference RNAs™. Results We introduce a novel universal reference sample that produces strong signal for all spots on the array, increasing the average fraction of detectable spots to 97%. Maximizing detectable spots on the reference image channel also decreases the variability of microarray data allowing for reliable detection of smaller differential gene expression changes. The reference sample is derived from sequence contained in the parental EST clone vector pT7T3D-Pac and is called vector RNA (vRNA). We show that vRNA can also be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This reference sample can be made inexpensively in large quantities as a renewable resource that is consistent across experiments. Conclusion Results of this study show that vRNA provides a useful universal reference that yields high signal for almost all spots on a microarray, reduces variation and allows for comparisons between experiments and laboratories. Further, it can be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This type of reference allows for detection of small changes in differential expression while reference designs in general allow for large-scale multivariate experimental designs. vRNA in

  11. Performance of unbalanced QPSK in the presence of noisy reference and crosstalk

    NASA Technical Reports Server (NTRS)

    Divsalar, D.; Yuen, J. H.

    1979-01-01

    The problem of transmitting two telemetry data streams having different rates and different powers using unbalanced quadriphase shift keying (UQPSK) signaling is considered. It is noted that the presence of a noisy carrier phase reference causes a degradation in detection performance in coherent communications systems and that imperfect carrier synchronization not only attenuates the main demodulated signal voltage in UQPSK but also produces interchannel interference (crosstalk) which degrades the performance still further. Exact analytical expressions for symbol error probability of UQPSK in the presence of noise phase reference are derived.

  12. Order-Constrained Reference Priors with Implications for Bayesian Isotonic Regression, Analysis of Covariance and Spatial Models

    NASA Astrophysics Data System (ADS)

    Gong, Maozhen

    Selecting an appropriate prior distribution is a fundamental issue in Bayesian Statistics. In this dissertation, under the framework provided by Berger and Bernardo, I derive the reference priors for several models which include: Analysis of Variance (ANOVA)/Analysis of Covariance (ANCOVA) models with a categorical variable under common ordering constraints, the conditionally autoregressive (CAR) models and the simultaneous autoregressive (SAR) models with a spatial autoregression parameter rho considered. The performances of reference priors for ANOVA/ANCOVA models are evaluated by simulation studies with comparisons to Jeffreys' prior and Least Squares Estimation (LSE). The priors are then illustrated in a Bayesian model of the "Risk of Type 2 Diabetes in New Mexico" data, where the relationship between the type 2 diabetes risk (through Hemoglobin A1c) and different smoking levels is investigated. In both simulation studies and real data set modeling, the reference priors that incorporate internal order information show good performances and can be used as default priors. The reference priors for the CAR and SAR models are also illustrated in the "1999 SAT State Average Verbal Scores" data with a comparison to a Uniform prior distribution. Due to the complexity of the reference priors for both CAR and SAR models, only a portion (12 states in the Midwest) of the original data set is considered. The reference priors can give a different marginal posterior distribution compared to a Uniform prior, which provides an alternative for prior specifications for areal data in Spatial statistics.

  13. Validation of the Australian diagnostic reference levels for paediatric multi detector computed tomography: a comparison of RANZCR QUDI data and subsequent NDRLS data from 2012 to 2015.

    PubMed

    Anna, Hayton; Wallace, Anthony; Thomas, Peter

    2017-03-01

    The national diagnostic reference level service (NDRLS), was launched in 2011, however no paediatric data were submitted during the first calendar year of operation. As such, Australian national diagnostic reference levels (DRLs), for paediatric multi detector computed tomography (MDCT), were established using data obtained from a Royal Australian and New Zealand College of Radiologists (RANZCR), Quality Use of Diagnostic Imaging (QUDI), study. Paediatric data were submitted to the NDRLS in 2012 through 2015. An analysis has been made of the NDRLS paediatric data using the same method as was used to analyse the QUDI data to establish the Australian national paediatric DRLs for MDCT. An analysis of the paediatric NDRLS data has also been made using the method used to calculate the Australian national adult DRLs for MDCT. A comparison between the QUDI data and subsequent NDRLS data shows the NDRLS data to be lower on average for the Head and AbdoPelvis protocol and similar for the chest protocol. Using an average of NDRLS data submitted between 2012 and 2015 implications for updated paediatric DRLS are considered.

  14. A global dataset of crowdsourced land cover and land use reference data.

    PubMed

    Fritz, Steffen; See, Linda; Perger, Christoph; McCallum, Ian; Schill, Christian; Schepaschenko, Dmitry; Duerauer, Martina; Karner, Mathias; Dresel, Christopher; Laso-Bayas, Juan-Carlos; Lesiv, Myroslava; Moorthy, Inian; Salk, Carl F; Danylo, Olha; Sturn, Tobias; Albrecht, Franziska; You, Liangzhi; Kraxner, Florian; Obersteiner, Michael

    2017-06-13

    Global land cover is an essential climate variable and a key biophysical driver for earth system models. While remote sensing technology, particularly satellites, have played a key role in providing land cover datasets, large discrepancies have been noted among the available products. Global land use is typically more difficult to map and in many cases cannot be remotely sensed. In-situ or ground-based data and high resolution imagery are thus an important requirement for producing accurate land cover and land use datasets and this is precisely what is lacking. Here we describe the global land cover and land use reference data derived from the Geo-Wiki crowdsourcing platform via four campaigns. These global datasets provide information on human impact, land cover disagreement, wilderness and land cover and land use. Hence, they are relevant for the scientific community that requires reference data for global satellite-derived products, as well as those interested in monitoring global terrestrial ecosystems in general.

  15. A global dataset of crowdsourced land cover and land use reference data

    PubMed Central

    Fritz, Steffen; See, Linda; Perger, Christoph; McCallum, Ian; Schill, Christian; Schepaschenko, Dmitry; Duerauer, Martina; Karner, Mathias; Dresel, Christopher; Laso-Bayas, Juan-Carlos; Lesiv, Myroslava; Moorthy, Inian; Salk, Carl F.; Danylo, Olha; Sturn, Tobias; Albrecht, Franziska; You, Liangzhi; Kraxner, Florian; Obersteiner, Michael

    2017-01-01

    Global land cover is an essential climate variable and a key biophysical driver for earth system models. While remote sensing technology, particularly satellites, have played a key role in providing land cover datasets, large discrepancies have been noted among the available products. Global land use is typically more difficult to map and in many cases cannot be remotely sensed. In-situ or ground-based data and high resolution imagery are thus an important requirement for producing accurate land cover and land use datasets and this is precisely what is lacking. Here we describe the global land cover and land use reference data derived from the Geo-Wiki crowdsourcing platform via four campaigns. These global datasets provide information on human impact, land cover disagreement, wilderness and land cover and land use. Hence, they are relevant for the scientific community that requires reference data for global satellite-derived products, as well as those interested in monitoring global terrestrial ecosystems in general. PMID:28608851

  16. HEAD CIRCUMFERENCE REFERENCES FOR SCHOOL AGE CHILDREN IN WESTERN ROMANIA.

    PubMed

    Chirita-Emandi, Adela; Doros, Gabriela; Simina, Iulia Jurca; Gafencu, Mihai; Puiu, Maria

    2015-01-01

    To provide head circumference references for school-aged children in western Romania, and compare them with references from other European countries. A total of 2742 children, aged 6-19 years, from Timis county, were examined by medical students, between February 2010-June 2011. Head circumference references were constructed by Cole's LMS method with LMSChartMaker software. The Romanian 3rd, 50th and 97th percentiles for head circumference were compared with recent references from Belgium and Germany. Generally, boys show significantly larger head circumference compared to girls at any age. The head circumference increments between 6 and 19 years are < 1 cm/year. Head circumference increments decrease in increasing age of the children. In girls, adult head circumference is reached at the age of 16 years, whereas head circumference growth continues, in boys, slowly until 18 years. The comparison of Romanian head percentiles with those from Belgium and Germany revealed a smaller head circumference in Romanian children (both girls and boys). Comparing head circumference references from Romania to those from Germany and Belgium, we found lower median head circumference in Romanian boys and girls, that could be explained by a taller stature of boys and girls in Germany and Belgium compared to Romania.

  17. Electronic heterodyne recording and processing of optical holograms using phase modulated reference waves

    NASA Technical Reports Server (NTRS)

    Decker, A. J.; Pao, Y.-H.; Claspy, P. C.

    1978-01-01

    The use of a phase-modulated reference wave for the electronic heterodyne recording and processing of a hologram is described. Heterodyne recording is used to eliminate the self-interference terms of a hologram and to create a Leith-Upatnieks hologram with coaxial object and reference waves. Phase modulation is also shown to be the foundation of a multiple-view hologram system. When combined with hologram scale transformations, heterodyne recording is the key to general optical processing. Spatial filtering is treated as an example.

  18. Simple Web-based interactive key development software (WEBiKEY) and an example key for Kuruna (Poaceae: Bambusoideae).

    PubMed

    Attigala, Lakshmi; De Silva, Nuwan I; Clark, Lynn G

    2016-04-01

    Programs that are user-friendly and freely available for developing Web-based interactive keys are scarce and most of the well-structured applications are relatively expensive. WEBiKEY was developed to enable researchers to easily develop their own Web-based interactive keys with fewer resources. A Web-based multiaccess identification tool (WEBiKEY) was developed that uses freely available Microsoft ASP.NET technologies and an SQL Server database for Windows-based hosting environments. WEBiKEY was tested for its usability with a sample data set, the temperate woody bamboo genus Kuruna (Poaceae). WEBiKEY is freely available to the public and can be used to develop Web-based interactive keys for any group of species. The interactive key we developed for Kuruna using WEBiKEY enables users to visually inspect characteristics of Kuruna and identify an unknown specimen as one of seven possible species in the genus.

  19. Decision Trajectories in Dementia Care Networks: Decisions and Related Key Events.

    PubMed

    Groen-van de Ven, Leontine; Smits, Carolien; Oldewarris, Karen; Span, Marijke; Jukema, Jan; Eefsting, Jan; Vernooij-Dassen, Myrra

    2017-10-01

    This prospective multiperspective study provides insight into the decision trajectories of people with dementia by studying the decisions made and related key events. This study includes three waves of interviews, conducted between July 2010 and July 2012, with 113 purposefully selected respondents (people with beginning to advanced stages of dementia and their informal and professional caregivers) completed in 12 months (285 interviews). Our multilayered qualitative analysis consists of content analysis, timeline methods, and constant comparison. Four decision themes emerged-managing daily life, arranging support, community living, and preparing for the future. Eight key events delineate the decision trajectories of people with dementia. Decisions and key events differ between people with dementia living alone and living with a caregiver. Our study clarifies that decisions relate not only to the disease but to living with the dementia. Individual differences in decision content and sequence may effect shared decision-making and advance care planning.

  20. Social Comparison Processes in an Organizational Context: New Directions

    ERIC Educational Resources Information Center

    Goodman, Paul S.; Haisley, Emily

    2007-01-01

    The goal of this article is to frame some new directions to social comparison research in organizational settings. Four themes are developed. First, we examine the role of organizational variables in shaping the basic sub processes in social comparison, such as the selection of referents. The second theme focuses on the meaning of level of…

  1. Comparison of alternative flue gas dry treatment technologies in waste-to-energy processes.

    PubMed

    Dal Pozzo, Alessandro; Antonioni, Giacomo; Guglielmi, Daniele; Stramigioli, Carlo; Cozzani, Valerio

    2016-05-01

    Acid gases such as HCl and SO2 are harmful both for human health and ecosystem integrity, hence their removal is a key step of the flue gas treatment of Waste-to-Energy (WtE) plants. Methods based on the injection of dry sorbents are among the Best Available Techniques for acid gas removal. In particular, systems based on double reaction and filtration stages represent nowadays an effective technology for emission control. The aim of the present study is the simulation of a reference two-stage (2S) dry treatment system performance and its comparison to three benchmarking alternatives based on single stage sodium bicarbonate injection. A modelling procedure was applied in order to identify the optimal operating configuration of the 2S system for different reference waste compositions, and to determine the total annual cost of operation. Taking into account both operating and capital costs, the 2S system appears the most cost-effective solution for medium to high chlorine content wastes. A Monte Carlo sensitivity analysis was carried out to assess the robustness of the results. Copyright © 2016. Published by Elsevier Ltd.

  2. A Comparative Study of Different EEG Reference Choices for Diagnosing Unipolar Depression.

    PubMed

    Mumtaz, Wajid; Malik, Aamir Saeed

    2018-06-02

    The choice of an electroencephalogram (EEG) reference has fundamental importance and could be critical during clinical decision-making because an impure EEG reference could falsify the clinical measurements and subsequent inferences. In this research, the suitability of three EEG references was compared while classifying depressed and healthy brains using a machine-learning (ML)-based validation method. In this research, the EEG data of 30 unipolar depressed subjects and 30 age-matched healthy controls were recorded. The EEG data were analyzed in three different EEG references, the link-ear reference (LE), average reference (AR), and reference electrode standardization technique (REST). The EEG-based functional connectivity (FC) was computed. Also, the graph-based measures, such as the distances between nodes, minimum spanning tree, and maximum flow between the nodes for each channel pair, were calculated. An ML scheme provided a mechanism to compare the performances of the extracted features that involved a general framework such as the feature extraction (graph-based theoretic measures), feature selection, classification, and validation. For comparison purposes, the performance metrics such as the classification accuracies, sensitivities, specificities, and F scores were computed. When comparing the three references, the diagnostic accuracy showed better performances during the REST, while the LE and AR showed less discrimination between the two groups. Based on the results, it can be concluded that the choice of appropriate reference is critical during the clinical scenario. The REST reference is recommended for future applications of EEG-based diagnosis of mental illnesses.

  3. Improvements in the Global Reference Atmospheric Model and comparisons with a global 3-D numerical model

    NASA Technical Reports Server (NTRS)

    Justus, C. G.; Alyea, F. N.; Chimonas, George; Cunnold, D. M.

    1989-01-01

    The status of the Global Reference Atmospheric Model (GRAM) and the Mars Global Reference Atmospheric Model (MARS-GRAM) is reviewed. The wavelike perturbations observed in the Viking 1 and 2 surface pressure data, in the Mariner 9 IR spectroscopy data, and in the Viking 1 and 2 lander entry profiles were studied and the results interpreted.

  4. Comparison of effectiveness of biosimilar filgrastim (Nivestim™), reference Amgen filgrastim and pegfilgrastim in febrile neutropenia primary prevention in breast cancer patients treated with neo(adjuvant) TAC: a non-interventional cohort study.

    PubMed

    Brito, M; Esteves, S; André, R; Isidoro, M; Moreira, A

    2016-02-01

    Biosimilars are supported by limited clinical data at the time of approval. Recently, Nivestim™, a biosimilar of reference of filgrastim, was approved for prevention of chemotherapy-related febrile neutropenia (FN). To add clinical experience to this new biosimilar, we performed a study to compare the effectiveness of Nivestim™ with reference filgrastim and pegfilgrastim in FN prevention in patients receiving high-risk FN chemotherapy. This is a comparative cohort study, with retrospective data collection. Three cohorts were identified according to the type of primary prophylaxis employed over different time periods: reference filgrastim (2004-2006), pegfilgrastim (2007-2008) and biosimilar filgrastim (2011-2012). The study included female patients with early breast cancer that received FN primary prophylaxis during (neo)adjuvant docetaxel/doxorubicin/cyclophosphamide (TAC). Reference filgrastim cohort included 147 patients and pegfilgrastim and biosimilar filgrastim cohorts 139 and 134 patients, respectively. FN rates per patient/cycle were 16 % (95 % confidence interval (CI) 10.2-22.5 %)/3 % (95 % CI 2.1-4.7 %) in the reference filgrastim group, 9 % (95 % CI 4.5-14.6 %)/2 % (95 % CI 1.3-3.6 %) in the pegfilgrastim group and 16 % (95 % CI 10.0-22.9 %)/4 % (95 % CI 2.5-5.3 %) in the biosimilar filgrastim cohort. The median absolute neutrophil count (ANC) at FN presentation was lower in the biosimilar group in comparison with reference filgrastim. FN episodes with ANC < 100 cells/μL were more frequent in the biosimilar group (50 %) when compared with reference filgrastim (4 %) and pegfilgrastim (6 %). No differences concerning FN complications were seen, with the exception of more chemotherapy delays in the biosimilar group when compared with pegfilgrastim. No differences in biosimilar effectiveness were detected. The clinical relevance of the profound neutropenia found in the biosimilar cohort needs further attention.

  5. A comprehensive approach to identify reliable reference gene candidates to investigate the link between alcoholism and endocrinology in Sprague-Dawley rats.

    PubMed

    Taki, Faten A; Abdel-Rahman, Abdel A; Zhang, Baohong

    2014-01-01

    Gender and hormonal differences are often correlated with alcohol dependence and related complications like addiction and breast cancer. Estrogen (E2) is an important sex hormone because it serves as a key protein involved in organism level signaling pathways. Alcoholism has been reported to affect estrogen receptor signaling; however, identifying the players involved in such multi-faceted syndrome is complex and requires an interdisciplinary approach. In many situations, preliminary investigations included a straight forward, yet informative biotechniques such as gene expression analyses using quantitative real time PCR (qRT-PCR). The validity of qRT-PCR-based conclusions is affected by the choice of reliable internal controls. With this in mind, we compiled a list of 15 commonly used housekeeping genes (HKGs) as potential reference gene candidates in rat biological models. A comprehensive comparison among 5 statistical approaches (geNorm, dCt method, NormFinder, BestKeeper, and RefFinder) was performed to identify the minimal number as well the most stable reference genes required for reliable normalization in experimental rat groups that comprised sham operated (SO), ovariectomized rats in the absence (OVX) or presence of E2 (OVXE2). These rat groups were subdivided into subgroups that received alcohol in liquid diet or isocalroic control liquid diet for 12 weeks. Our results showed that U87, 5S rRNA, GAPDH, and U5a were the most reliable gene candidates for reference genes in heart and brain tissue. However, different gene stability ranking was specific for each tissue input combination. The present preliminary findings highlight the variability in reference gene rankings across different experimental conditions and analytic methods and constitute a fundamental step for gene expression assays.

  6. Comparison between reference atmosphere winds and radar winds from selected locations

    NASA Technical Reports Server (NTRS)

    Manson, A. H.; Meek, C. E.; Vincent, R. A.; Craig, R. L.; Phillips, A.; Fraser, G. J.; Smith, M. J.; Fellous, J. L.; Massebeuf, M.; Chandra, S.

    1990-01-01

    Zonal and meridional 60-110-km wind profiles obtained by radar measurements at Saskatoon, Adelaide, Christchurch, Puerto Rico, and Mawson are presented graphically and compared with those from the COSPAR International Reference Atmosphere (CIRA) for 1986. Good general agreement is found below about 80 km, but above 80 km the CIRA 1986 models show discrepancies, including: (1) no spring tongue of weak westward flow at latitudes 20-70 deg; (2) too strong an eastward flow at 20-52 deg in summer; (3) too great reversal heights at 35-43 deg N in summer; and (4) too strong (by a factor of 2) summer and winter jets at 65-70 deg N.

  7. Compositional analysis of biomass reference materials: Results from an interlaboratory study

    DOE PAGES

    Templeton, David W.; Wolfrum, Edward J.; Yen, James H.; ...

    2015-10-29

    Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491–8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached andmore » an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs’ compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. Here, the major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original

  8. [Study on the experimental application of floating-reference method to noninvasive blood glucose sensing].

    PubMed

    Yu, Hui; Qi, Dan; Li, Heng-da; Xu, Ke-xin; Yuan, Wei-jie

    2012-03-01

    Weak signal, low instrument signal-to-noise ratio, continuous variation of human physiological environment and the interferences from other components in blood make it difficult to extract the blood glucose information from near infrared spectrum in noninvasive blood glucose measurement. The floating-reference method, which analyses the effect of glucose concentration variation on absorption coefficient and scattering coefficient, gets spectrum at the reference point and the measurement point where the light intensity variations from absorption and scattering are counteractive and biggest respectively. By using the spectrum from reference point as reference, floating-reference method can reduce the interferences from variation of physiological environment and experiment circumstance. In the present paper, the effectiveness of floating-reference method working on improving prediction precision and stability was assessed through application experiments. The comparison was made between models whose data were processed with and without floating-reference method. The results showed that the root mean square error of prediction (RMSEP) decreased by 34.7% maximally. The floating-reference method could reduce the influences of changes of samples' state, instrument noises and drift, and improve the models' prediction precision and stability effectively.

  9. New developments in electronic reference controls for frequency domain optical sensing

    NASA Astrophysics Data System (ADS)

    Chatni, M. R.; Li, G.; Porterfield, D. M.

    2009-05-01

    The reference optical path is essential for optical systems which function on the basis of light interference. In the case of frequency domain (FD) fluorescence life-time optrodes, a reference LED is used as a standard for calculating the phase angle. The reference LED is configured so that radiation travels the same length to the detector as that of the fluorescence signal being analyzed. The phase shift, which provides details of fluorescence lifetime, is measured between these two signals - the fluorescence signal and reference LED signal, using a photodetector. We have designed, developed and implemented a FD optrode system without a reference LED. The key requirement of such a system is that phase shifts due to optics at wavelength of fluorescence and electronics have to be calibrated. In the reference-free system, the reference signal comes from the lock-in-amplifier which also drives the excitation LED. The lock-in-amplifier measures the phase shift between the excitation signal and the fluorescence emission signal from the photodetector and is locked at the frequency of modulation of the excitation signal. This insures higher signal to noise ratio and low-noise measurements. The reference-free optrode system removes some constraints on the coupling optics, which help improve the overall performance of the system. After development of electronics, and optimization of coupling optics, the system was calibrated in different oxygen concentration solutions to measure fluorescence intensity and lifetime of the oxygen sensitive dye platinum tetrakis (pentafluorophenyl) porphine (PtTFPP).

  10. Mechanisms of Reference Frame Selection in Spatial Term Use: Computational and Empirical Studies

    ERIC Educational Resources Information Center

    Schultheis, Holger; Carlson, Laura A.

    2017-01-01

    Previous studies have shown that multiple reference frames are available and compete for selection during the use of spatial terms such as "above." However, the mechanisms that underlie the selection process are poorly understood. In the current paper we present two experiments and a comparison of three computational models of selection…

  11. Celestial Reference Frames at Multiple Radio Wavelengths

    NASA Technical Reports Server (NTRS)

    Jacobs, Christopher S.

    2012-01-01

    In 1997 the IAU adopted the International Celestial Reference Frame (ICRF) built from S/X VLBI data. In response to IAU resolutions encouraging the extension of the ICRF to additional frequency bands, VLBI frames have been made at 24, 32, and 43 gigahertz. Meanwhile, the 8.4 gigahertz work has been greatly improved with the 2009 release of the ICRF-2. This paper discusses the motivations for extending the ICRF to these higher radio bands. Results to date will be summarized including evidence that the high frequency frames are rapidly approaching the accuracy of the 8.4 gigahertz ICRF-2. We discuss current limiting errors and prospects for the future accuracy of radio reference frames. We note that comparison of multiple radio frames is characterizing the frequency dependent systematic noise floor from extended source morphology and core shift. Finally, given Gaia's potential for high accuracy optical astrometry, we have simulated the precision of a radio-optical frame tie to be approximately10-15 microarcseconds ((1-sigma) (1-standard deviation), per component).

  12. Final report of supplementary comparison AFRIMETS.AUV.A-S1: primary pressure calibration of LS2aP microphones according to IEC 61094-2, over the frequency range 1 Hz to 31.5 kHz.

    NASA Astrophysics Data System (ADS)

    Nel, R.; Barrera-Figueroa, S.; Dobrowolska, D.; Defilippo Soares, Z. M.; Maina, A. K.; Hof, C.

    2016-01-01

    This is the final report of the AFRIMETS.AUV-S1 comparison of the pressure sensitivity, modulus and phase, of LS2aP microphones in the frequency range 1 Hz to 31.5 kHz in accordance with IEC 61094-2. Six national metrology institutes from three different regional metrology organisations participated in the comparison for which two LS2aP microphones were circulated simultaneously to all the participants in a hybrid-star configuration. The comparison reference values were calculated as the weighted mean for modulus and phase for each individual microphone. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Simple Web-based interactive key development software (WEBiKEY) and an example key for Kuruna (Poaceae: Bambusoideae)1

    PubMed Central

    Attigala, Lakshmi; De Silva, Nuwan I.; Clark, Lynn G.

    2016-01-01

    Premise of the study: Programs that are user-friendly and freely available for developing Web-based interactive keys are scarce and most of the well-structured applications are relatively expensive. WEBiKEY was developed to enable researchers to easily develop their own Web-based interactive keys with fewer resources. Methods and Results: A Web-based multiaccess identification tool (WEBiKEY) was developed that uses freely available Microsoft ASP.NET technologies and an SQL Server database for Windows-based hosting environments. WEBiKEY was tested for its usability with a sample data set, the temperate woody bamboo genus Kuruna (Poaceae). Conclusions: WEBiKEY is freely available to the public and can be used to develop Web-based interactive keys for any group of species. The interactive key we developed for Kuruna using WEBiKEY enables users to visually inspect characteristics of Kuruna and identify an unknown specimen as one of seven possible species in the genus. PMID:27144109

  14. Systematic review of serum steroid reference intervals developed using mass spectrometry.

    PubMed

    Tavita, Nevada; Greaves, Ronda F

    2017-12-01

    The aim of this study was to perform a systematic review of the published literature to determine the available serum/plasma steroid reference intervals generated by mass spectrometry (MS) methods across all age groups in healthy subjects and to suggest recommendations to achieve common MS based reference intervals for serum steroids. MEDLINE, EMBASE and PubMed databases were used to conduct a comprehensive search for English language, MS-based reference interval studies for serum/plasma steroids. Selection of steroids to include was based on those listed in the Royal College of Pathologists of Australasia Quality Assurance Programs, Chemical Pathology, Endocrine Program. This methodology has been registered onto the PROSPERO International prospective register of systematic reviews (ID number: CRD42015029637). After accounting for duplicates, a total of 60 manuscripts were identified through the search strategy. Following critical evaluation, a total of 16 studies were selected. Of the 16 studies, 12 reported reference intervals for testosterone, 11 for 17 hydroxy-progesterone, nine for androstenedione, six for cortisol, three for progesterone, two for dihydrotestosterone and only one for aldosterone and dehydroepiandrosterone sulphate. No studies established MS-based reference intervals for oestradiol. As far as we are aware, this report provides the first comparison of the peer reviewed literature for serum/plasma steroid reference intervals generated by MS-based methods. The reference intervals based on these published studies can be used to inform the process to develop common reference intervals, and agreed reporting units for mass spectrometry based steroid methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Vertebral heights and ratios are not only race-specific, but also gender- and region-specific: establishment of reference values for mainland Chinese.

    PubMed

    Ning, Lei; Song, Li-Jiang; Fan, Shun-Wu; Zhao, Xing; Chen, Yi-Lei; Li, Zhao-Zhi; Hu, Zi-Ang

    2017-10-11

    This study established gender-specific reference values in mainland Chinese (MC) and is important for quantitative morphometry for diagnosis and epidemiological study of osteoporotic vertebral compressive fracture. Comparisons of reference values among different racial populations are then performed to demonstrate the MC-specific characteristic. Osteoporotic vertebral compressive fracture (OVCF) is a common complication of osteoporosis in the elder population. Clinical diagnosis and epidemiological study of OVCF often employ quantitative morphometry, which relies heavily on the comparison of patients' vertebral parameters to existing reference values derived from the normal population. Thus, reference values are crucial in clinical diagnosis. To our knowledge, this is the first study to establish reference values of the mainland Chinese (MC) for quantitative morphometry. Vertebral heights including anterior (Ha), middle (Hm), posterior (Hp) heights, and predicted posterior height (pp) from T4 to L5 were obtained; and ratios of Ha/Hp, Hm/Hp and Hp/pp. were calculated from 585 MC (both female and male) for establishing reference values and subsequent comparisons with other studies. Vertebral heights increased progressively from T4 to L3 but then decreased in L4 and L5. Both genders showed similar ratios of vertebral dimensions, but male vertebrae were statistically larger than those of female (P < 0.01). Vertebral size of MC population was smaller than that of US and UK population, but was surprisingly larger than that of Hong Kong Chinese, although these two are commonly considered as one race. Data from different racial populations showed similar dimensional ratios in all vertebrae. We established gender-specific reference values for MC. Our results also indicated the necessity of establishing reference values that are not only race- and gender-specific, but also population- or region-specific for accurate quantitative morphometric assessment of OVCF.

  16. The Processing Cost of Reference Set Computation: Acquisition of Stress Shift and Focus

    ERIC Educational Resources Information Center

    Reinhart, Tanya

    2004-01-01

    Reference set computation -- the construction of a (global) comparison set to determine whether a given derivation is appropriate in context -- comes with a processing cost. I argue that this cost is directly visible at the acquisition stage: In those linguistic areas in which it has been independently established that such computation is indeed…

  17. Key Role of Sequencing to Trace Hepatitis A Viruses Circulating in Italy During a Large Multi-Country European Foodborne Outbreak in 2013

    PubMed Central

    Bruni, Roberto; Taffon, Stefania; Equestre, Michele; Chionne, Paola; Madonna, Elisabetta; Rizzo, Caterina; Tosti, Maria Elena; Alfonsi, Valeria; Ricotta, Lara; De Medici, Dario; Di Pasquale, Simona; Scavia, Gaia; Pavoni, Enrico; Losio, Marina Nadia; Romanò, Luisa; Zanetti, Alessandro Remo; Morea, Anna; Pacenti, Monia; Palù, Giorgio; Capobianchi, Maria Rosaria; Chironna, Maria; Pompa, Maria Grazia; Ciccaglione, Anna Rita

    2016-01-01

    Background Foodborne Hepatitis A Virus (HAV) outbreaks are being recognized as an emerging public health problem in industrialized countries. In 2013 three foodborne HAV outbreaks occurred in Europe and one in USA. During the largest of the three European outbreaks, most cases occurred in Italy (>1,200 cases as of March 31, 2014). A national Task Force was established at the beginning of the outbreak by the Ministry of Health. Mixed frozen berries were early demonstrated to be the source of infection by the identity of viral sequences in patients and in food. In the present study the molecular characterization of HAV isolates from 355 Italian cases is reported. Methods Molecular characterization was carried out by PCR/sequencing (VP1/2A region), comparison with reference strains and phylogenetic analysis. Results A unique strain was responsible for most characterized cases (235/355, 66.1%). Molecular data had a key role in tracing this outbreak, allowing 110 out of the 235 outbreak cases (46.8%) to be recognized in absence of any other link. The data also showed background circulation of further unrelated strains, both autochthonous and travel related, whose sequence comparison highlighted minor outbreaks and small clusters, most of them unrecognized on the basis of epidemiological data. Phylogenetic analysis showed most isolates from travel related cases clustering with reference strains originating from the same geographical area of travel. Conclusions In conclusion, the study documents, in a real outbreak context, the crucial role of molecular analysis in investigating an old but re-emerging pathogen. Improving the molecular knowledge of HAV strains, both autochthonous and circulating in countries from which potentially contaminated foods are imported, will become increasingly important to control outbreaks by supporting trace back activities, aiming to identify the geographical source(s) of contaminated food, as well as public health interventions. PMID

  18. Key Role of Sequencing to Trace Hepatitis A Viruses Circulating in Italy During a Large Multi-Country European Foodborne Outbreak in 2013.

    PubMed

    Bruni, Roberto; Taffon, Stefania; Equestre, Michele; Chionne, Paola; Madonna, Elisabetta; Rizzo, Caterina; Tosti, Maria Elena; Alfonsi, Valeria; Ricotta, Lara; De Medici, Dario; Di Pasquale, Simona; Scavia, Gaia; Pavoni, Enrico; Losio, Marina Nadia; Romanò, Luisa; Zanetti, Alessandro Remo; Morea, Anna; Pacenti, Monia; Palù, Giorgio; Capobianchi, Maria Rosaria; Chironna, Maria; Pompa, Maria Grazia; Ciccaglione, Anna Rita

    2016-01-01

    Foodborne Hepatitis A Virus (HAV) outbreaks are being recognized as an emerging public health problem in industrialized countries. In 2013 three foodborne HAV outbreaks occurred in Europe and one in USA. During the largest of the three European outbreaks, most cases occurred in Italy (>1,200 cases as of March 31, 2014). A national Task Force was established at the beginning of the outbreak by the Ministry of Health. Mixed frozen berries were early demonstrated to be the source of infection by the identity of viral sequences in patients and in food. In the present study the molecular characterization of HAV isolates from 355 Italian cases is reported. Molecular characterization was carried out by PCR/sequencing (VP1/2A region), comparison with reference strains and phylogenetic analysis. A unique strain was responsible for most characterized cases (235/355, 66.1%). Molecular data had a key role in tracing this outbreak, allowing 110 out of the 235 outbreak cases (46.8%) to be recognized in absence of any other link. The data also showed background circulation of further unrelated strains, both autochthonous and travel related, whose sequence comparison highlighted minor outbreaks and small clusters, most of them unrecognized on the basis of epidemiological data. Phylogenetic analysis showed most isolates from travel related cases clustering with reference strains originating from the same geographical area of travel. In conclusion, the study documents, in a real outbreak context, the crucial role of molecular analysis in investigating an old but re-emerging pathogen. Improving the molecular knowledge of HAV strains, both autochthonous and circulating in countries from which potentially contaminated foods are imported, will become increasingly important to control outbreaks by supporting trace back activities, aiming to identify the geographical source(s) of contaminated food, as well as public health interventions.

  19. Conducting indirect-treatment-comparison and network-meta-analysis studies: report of the ISPOR Task Force on Indirect Treatment Comparisons Good Research Practices: part 2.

    PubMed

    Hoaglin, David C; Hawkins, Neil; Jansen, Jeroen P; Scott, David A; Itzler, Robbin; Cappelleri, Joseph C; Boersma, Cornelis; Thompson, David; Larholt, Kay M; Diaz, Mireya; Barrett, Annabel

    2011-06-01

    Evidence-based health care decision making requires comparison of all relevant competing interventions. In the absence of randomized controlled trials involving a direct comparison of all treatments of interest, indirect treatment comparisons and network meta-analysis provide useful evidence for judiciously selecting the best treatment(s). Mixed treatment comparisons, a special case of network meta-analysis, combine direct evidence and indirect evidence for particular pairwise comparisons, thereby synthesizing a greater share of the available evidence than traditional meta-analysis. This report from the International Society for Pharmacoeconomics and Outcomes Research Indirect Treatment Comparisons Good Research Practices Task Force provides guidance on technical aspects of conducting network meta-analyses (our use of this term includes most methods that involve meta-analysis in the context of a network of evidence). We start with a discussion of strategies for developing networks of evidence. Next we briefly review assumptions of network meta-analysis. Then we focus on the statistical analysis of the data: objectives, models (fixed-effects and random-effects), frequentist versus Bayesian approaches, and model validation. A checklist highlights key components of network meta-analysis, and substantial examples illustrate indirect treatment comparisons (both frequentist and Bayesian approaches) and network meta-analysis. A further section discusses eight key areas for future research. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  20. Selection and validation of reference genes for miRNA expression studies during porcine pregnancy.

    PubMed

    Wessels, Jocelyn M; Edwards, Andrew K; Zettler, Candace; Tayade, Chandrakant

    2011-01-01

    MicroRNAs comprise a family of small non-coding RNAs that modulate several developmental and physiological processes including pregnancy. Their ubiquitous presence is confirmed in mammals, worms, flies and plants. Although rapid advances have been made in microRNA research, information on stable reference genes for validation of microRNA expression is still lacking. Real time PCR is a widely used tool to quantify gene transcripts. An appropriate reference gene must be chosen to minimize experimental error in this system. A small difference in miRNA levels between experimental samples can be biologically meaningful as these entities can affect multiple targets in a pathway. This study examined the suitability of six commercially available reference genes (RNU1A, RNU5A, RNU6B, SNORD25, SCARNA17, and SNORA73A) in maternal-fetal tissues from healthy and spontaneously arresting/dying conceptuses from sows were separately analyzed at gestation day 20. Comparisons were also made with non-pregnant endometrial tissues from sows. Spontaneous fetal loss is a prime concern to the commercial pork industry. Our laboratory has previously identified deficits in vasculature development at maternal-fetal interface as one of the major participating causes of fetal loss. Using this well-established model, we have extended our studies to identify suitable microRNA reference genes. A methodical approach to assessing suitability was adopted using standard curve and melting curve analysis, PCR product sequencing, real time PCR expression in a panel of gestational tissues, and geNorm and NormFinder analysis. Our quantitative real time PCR analysis confirmed expression of all 6 reference genes in maternal and fetal tissues. All genes were uniformly expressed in tissues from healthy and spontaneously arresting conceptus attachment sites. Comparisons between tissue types (maternal/fetal/non-pregnant) revealed significant differences for RNU5A, RNU6B, SCARNA17, and SNORA73A expression. Based